WorldWideScience

Sample records for rdx-based gun propellants

  1. HMX based enhanced energy LOVA gun propellant

    Energy Technology Data Exchange (ETDEWEB)

    Sanghavi, R.R. [High Energy Materials Research Laboratory, Pune 411021 (India)]. E-mail: sanghavirr@yahoo.co.uk; Kamale, P.J. [High Energy Materials Research Laboratory, Pune 411021 (India); Shaikh, M.A.R. [High Energy Materials Research Laboratory, Pune 411021 (India); Shelar, S.D. [High Energy Materials Research Laboratory, Pune 411021 (India); Kumar, K. Sunil [High Energy Materials Research Laboratory, Pune 411021 (India); Singh, Amarjit [High Energy Materials Research Laboratory, Pune 411021 (India)

    2007-05-08

    Efforts to develop gun propellants with low vulnerability have recently been focused on enhancing the energy with a further improvement in its sensitivity characteristics. These propellants not only prevent catastrophic disasters due to unplanned initiation of currently used gun propellants (based on nitrate esters) but also realize enhanced energy levels to increase the muzzle velocity of the projectiles. Now, in order to replace nitroglycerine, which is highly sensitive to friction and impact, nitramines meet the requirements as they offer superior energy due to positive heat of formation, typical stoichiometry with higher decomposition temperatures and also owing to negative oxygen balance are less sensitive than stoichiometrically balanced NG. RDX has been widely reported for use in LOVA propellant. In this paper we have made an effort to present the work on scantily reported nitramine HMX based LOVA gun propellant while incorporating energetic plasticizer glycidyl azide polymer to enhance the energy level. HMX is known to be thermally stable at higher temperature than RDX and also proved to be less vulnerable to small scale shaped charge jet attack as its decomposition temperature is 270 deg. C. HMX also offers improved impulse due to its superior heat of formation (+17 kcal/mol) as compared to RDX (+14 kcal/mol). It has also been reported that a break point will not appear until 35,000 psi for propellant comprising of 5 {mu}m HMX. Since no work has been reported in open literature regarding replacement of RDX by HMX, the present studies were carried out.

  2. Thermal Decomposition Behaviors and Burning Characteristics of AN/RDX-Based Composite Propellants Supplemented with MnO2 and Fe2O3

    Science.gov (United States)

    Kohga, Makoto; Naya, Tomoki

    2015-10-01

    Ammonium nitrate (AN)-based composite propellants have gained popularity because of the clean burning nature of AN as an oxidizer. However, such propellants have several disadvantages such as poor ignition and low burning rate. The burning characteristics of the AN propellant were improved when a portion of this propellant was replaced by an energetic material and the addition of a catalyst. In this study, RDX (1,3,5-trinitroperhydro-1,3,5-triazine) was used as the energetic material, and Fe2O3 and MnO2 were used as catalysts. The burning characteristics of the AN/RDX propellants supplemented with catalysts were investigated, and the effects of the replacement of AN by RDX and the catalyst addition were evaluated.

  3. Fabrication of Graded Porous and Skin-Core Structure RDX-Based Propellants via Supercritical CO2 Concentration Profile

    Science.gov (United States)

    Yang, Weitao; Li, Yuxiang; Ying, Sanjiu

    2015-04-01

    A fabrication process to produce graded porous and skin-core structure propellants via supercritical CO2 concentration profile is reported in this article. It utilizes a partial gas saturation technique to obtain nonequilibrium gas concentration profiles in propellants. Once foamed, the propellant obtains a graded porous or skin-pore structure. This fabrication method was studied with RDX(Hexogen)-based propellant under an SC-CO2 saturation condition. The principle was analyzed and the one-dimensional diffusion model was employed to estimate the gas diffusion coefficient and to predict the gas concentration profiles inside the propellant. Scanning electron microscopy images were used to analyze the effects of partial saturation on the inner structure. The results also suggested that the sorption time and desorption time played an important role in gas profile generation and controlled the inner structure of propellants.

  4. Gun barrel erosion - Comparison of conventional and LOVA gun propellants

    NARCIS (Netherlands)

    Hordijk, A.C.; Leurs, O.

    2006-01-01

    The research department Energetic Materials within TNO Defence, Security and Safety is involved in the development and (safety and insensitive munitions) testing of conventional (nitro cellulose based) and thermoplastic elastomer (TPE) based gun propellants. Recently our testing capabilities have

  5. Thermal Decomposition Behaviors and Burning Characteristics of AN/Nitramine-Based Composite Propellant

    Science.gov (United States)

    Naya, Tomoki; Kohga, Makoto

    2015-04-01

    Ammonium nitrate (AN) has attracted much attention due to its clean burning nature as an oxidizer. However, an AN-based composite propellant has the disadvantages of low burning rate and poor ignitability. In this study, we added nitramine of cyclotrimethylene trinitramine (RDX) or cyclotetramethylene tetranitramine (HMX) as a high-energy material to AN propellants to overcome these disadvantages. The thermal decomposition and burning rate characteristics of the prepared propellants were examined as the ratio of AN and nitramine was varied. In the thermal decomposition process, AN/RDX propellants showed unique mass loss peaks in the lower temperature range that were not observed for AN or RDX propellants alone. AN and RDX decomposed continuously as an almost single oxidizer in the AN/RDX propellant. In contrast, AN/HMX propellants exhibited thermal decomposition characteristics similar to those of AN and HMX, which decomposed almost separately in the thermal decomposition of the AN/HMX propellant. The ignitability was improved and the burning rate increased by the addition of nitramine for both AN/RDX and AN/HMX propellants. The increased burning rates of AN/RDX propellants were greater than those of AN/HMX. The difference in the thermal decomposition and burning characteristics was caused by the interaction between AN and RDX.

  6. Changing of ballistic parameters from aged gun propellants

    NARCIS (Netherlands)

    Klerk, W.P.C. de; Driel, C.A. van

    2003-01-01

    The various properties of an SB and a DB gun propellant were investigated before and after artificial ageing. It was found that the decrease of nitrocellulose (NC) molecular weight, due to ageing of gun propellants, leads to a decrease of the mechanical integrity of the propellant grains. The effect

  7. Green plasticizers for multibase gun propellants (Lecture)

    NARCIS (Netherlands)

    Schoolderman, C.; Driel, C.A. van; Zebregs, M.

    2007-01-01

    TNO Defence, Security and Safety has a long history of research on gun propellants. Areas investigated are formulating (new ingredients, optimization), manufacturing, charge design and lifetime assessment [1,2,3,4,5]. In conventional propellants inert plasticizers are used to alter performance,

  8. Burning properties and mechanical integrity of aged gun propellants

    NARCIS (Netherlands)

    Driel, C.A. van; Klerk, W.P.C. de

    2017-01-01

    Conventional gun propellants exhibit the phenomenon of nitrocellulose (NC) decomposition. Besides an effect on thermal stability of propellants, decomposition of NC has an effect on the mechanical integrity of the propellant grains. Enhanced grain fracture may lead to unacceptable changes of the

  9. Experimental set-up and results of the process of co-extruded perforated gun propellants

    NARCIS (Netherlands)

    Zebregs, M.; Driel, C.A. van

    2009-01-01

    Enhancement of gun performance can be obtained by increasing the propellant loading density or the energy content of the propellant. Serious consequences of these options are difficulties with regard to ignition and to gun barrel wear. Application of co-layered propellants is a good alternative,

  10. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    Energy Technology Data Exchange (ETDEWEB)

    Reed, J. R. [University of Tennessee, Knoxville (UTK); Carmichael, J. R. [Fermi National Accelerator Laboratory (FNAL); Gebhart, T. E. [University of Florida, Gainesville; Combs, Stephen Kirk [ORNL; Baylor, Larry R. [ORNL; Rasmussen, David A. [ORNL; Meitner, Steven J. [ORNL; Lyttle, Mark S. [ORNL

    2017-10-01

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze the dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet injectors for

  11. Analiza rezultata određivanja sadržaja stabilizatora u prirodno starenim barutima / Content of stabilizer determination results analysis of naturally aged gun propellants

    Directory of Open Access Journals (Sweden)

    Luka Grbović

    2006-04-01

    Full Text Available Praćenje sadržaja stabilizatora jedna je od suvremenih i pouzdanih metoda koja se u svetu, a i kod nas, primenjuje za kontrolu kemijske stabilnosti i prognoziranje veka upotrebljivosti baruta. Radi ocene kemijske stabilnosti baruta domaće proizvodnje u radu su analizirani rezultati određivanja sadržaja stabilizatora u prirodno starenim jednobaznim barutima tipa NC i NCD i dvobaznim barutima tipa NGB i NGH. Pri tome su uporedno analizirani rezultati uzoraka iz kolekcija baruta iz Kragujevca (KB-1 i Zelenike (KB-2. Dobijeni rezultati ukazuju na znatno brži pad stabilnosti uzoraka baruta iz kolekcije KB-2, što se može objasniti značajnim uticajem klimatskih uslova. Osim toga, dobijeni rezultati potvrđuju uticaj mnogih faktora na kemijsku stabilnost baruta, kao što su: sastav, kvalitet sirovina, tehnološki postupak, oblik i dimenzije barutnog zrna i sl. / Monitoring of the stabilizer content is one of the modern and reliable methods in the world, and here also, which is used to control chemical stability and to predict the usage time of gun propellants. For the purpose of evaluation of gun propellants' chemical stability manufactured in our country, in this paper -we analyzed results from the content of stabilizer determination in naturally aged single base, NC and NCD type, and double base, NGB and NGH type of gun propellants. At the same time -we analyzed results from both collections of gun propellant samples, one from Kragujevac factory (KB-1 and the other from Zelenika factory (KB-2. Obtained results point that the stability decays faster for KB-2 collection samples, -which can be explained due to climate factors. Beside this influence, obtained results prove the influence of many factors on chemical stability of gun propellants: used components, quality of the ingredients, procedures of manufacture, shape and dimensions of gun propellant grains, etc.

  12. Determination of the Basis for Temperature Compensation in ETC Ignited Solid Propellant Guns

    National Research Council Canada - National Science Library

    Pesce-Rodriguez, R. A; Beyer, R. A

    2004-01-01

    A series of experiments and reanalysis of previously published results has led to the discovery of the key interaction between the plasma of an electrothermal igniter and the gun propellant in large caliber cannon...

  13. Innovative boron nitride-doped propellants

    Directory of Open Access Journals (Sweden)

    Thelma Manning

    2016-04-01

    Full Text Available The U.S. military has a need for more powerful propellants with balanced/stoichiometric amounts of fuel and oxidants. However, balanced and more powerful propellants lead to accelerated gun barrel erosion and markedly shortened useful barrel life. Boron nitride (BN is an interesting potential additive for propellants that could reduce gun wear effects in advanced propellants (US patent pending 2015-026P. Hexagonal boron nitride is a good lubricant that can provide wear resistance and lower flame temperatures for gun barrels. Further, boron can dope steel, which drastically improves its strength and wear resistance, and can block the formation of softer carbides. A scalable synthesis method for producing boron nitride nano-particles that can be readily dispersed into propellants has been developed. Even dispersion of the nano-particles in a double-base propellant has been demonstrated using a solvent-based processing approach. Stability of a composite propellant with the BN additive was verified. In this paper, results from propellant testing of boron nitride nano-composite propellants are presented, including closed bomb and wear and erosion testing. Detailed characterization of the erosion tester substrates before and after firing was obtained by electron microscopy, inductively coupled plasma and x-ray photoelectron spectroscopy. This promising boron nitride additive shows the ability to improve gun wear and erosion resistance without any destabilizing effects to the propellant. Potential applications could include less erosive propellants in propellant ammunition for large, medium and small diameter fire arms.

  14. Shock-to-detonation transition of RDX and NTO based composite high explosives: experiments and modeling

    Science.gov (United States)

    Baudin, Gerard; Roudot, Marie; Genetier, Marc

    2013-06-01

    Composite HMX and NTO based high explosives (HE) are widely used in ammunitions. Designing modern warheads needs robust and reliable models to compute shock ignition and detonation propagation inside HE. Comparing to a pressed HE, a composite HE is not porous and the hot-spots are mainly located at the grain - binder interface leading to a different behavior during shock-to-detonation transition. An investigation of how shock-to-detonation transition occurs inside composite HE containing RDX and NTO is proposed in this lecture. Two composite HE have been studied. The first one is HMX - HTPB 82:18. The second one is HMX - NTO - HTPB 12:72:16. These HE have been submitted to plane sustained shock waves at different pressure levels using a laboratory powder gun. Pressure signals are measured using manganin gauges inserted at several distances inside HE. The corresponding run-distances to detonation are determined using wedge test experiments where the plate impact is performed using a powder gun. Both HE exhibit a single detonation buildup curve in the distance - time diagram of shock-to-detonation transition. This feature seems a common shock-to-detonation behavior for composite HE without porosity. This behavior is also confirmed for a RDX - HTPB 85:15 based composite HE. Such a behavior is exploited to determine the heterogeneous reaction rate versus the shock pressure using a method based on the Cauchy-Riemann problem inversion. The reaction rate laws obtained allow to compute both run-distance to detonation and pressure signals.

  15. Simplified pipe gun

    International Nuclear Information System (INIS)

    Sorensen, H.; Nordskov, A.; Sass, B.; Visler, T.

    1987-01-01

    A simplified version of a deuterium pellet gun based on the pipe gun principle is described. The pipe gun is made from a continuous tube of stainless steel and gas is fed in from the muzzle end only. It is indicated that the pellet length is determined by the temperature gradient along the barrel right outside the freezing cell. Velocities of around 1000 m/s with a scatter of +- 2% are obtained with a propellant gas pressure of 40 bar

  16. Reduced sensitivity RDX obtained from bachmann RDX

    Energy Technology Data Exchange (ETDEWEB)

    Spyckerelle, Christian; Eck, Genevieve [EURENCO France, Sorgues Plant 1928 route d' Avignon, BP 311, 84706 Sorgues Cedex (France); Sjoeberg, Per; Amneus, Anna-Maria [EURENCO Sweden, SE-69186 Karlskoga (Sweden)

    2008-02-15

    In recent years much interest has been generated in a quality of reduced sensitivity RDX (RS-RDX), like I-RDX {sup registered} which, when incorporated in cast cure and even pressable plastic bonded explosives (PBX compositions), can confer reduced shock sensitivity as measured through gap test. At crystal level, lot of work has been done to try to determine which property or properties may explain the behaviour of the corresponding cast PBX composition. But up to now, and despite an international inter-laboratory comparison (Round Robin) of seven lots of RDX from five different manufacturers conducted from 2003 to 2005, even if some techniques lead to interesting results, there is no dedicated specification to apply to RS-RDX. This quality (I-RDX {sup registered}) has proved to retain its low sensitivity even after ageing, which does not seem to be the case for standard RDX produced by the Bachmann process (when re-crystallized under I-RDX conditions in order to obtain RS-RDX). It has been shown that the higher sensitivity of RDX produced by the Bachmann process, or the evolution of sensitivity after ageing of RS-RDX produced from Bachmann RDX may be linked to the presence of octogen (HMX) during the crystallization process. In order to check such hypothesis, low HMX content RDX produced by the Bachmann process has been prepared and evaluated in cast PBX composition (PBX N 109). Results of the characterization of such quality of RDX and its evaluation in cast PBX composition as well as ageing behaviour are presented and discussed; there are indications that removal of HMX from Bachmann RDX may lead to RS-RDX, which retains its RS character even after ageing. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  17. Studies of pellet acceleration with arc discharge heated propellants

    International Nuclear Information System (INIS)

    Schuresko, D.D.

    1985-01-01

    An arc discharge has been utilized to heat gaseous propellants in a pneumatic pellet gun. A cylindrical arc chamber is interposed between the propellant inlet valve and the gun breech and fitted with a ceramic insert for generating swirl in the incoming gas stream. The arc is initiated after the propellant valve opens and the breech pressure starts to rise; a typical discharge lasts 300 microseconds with peak currents u to 2 kA at arc voltages ranging from 100 to 400 V. The system is instrumented with piezoelectric pressure transducers at the propellant valve outlet, gun breech, and gun muzzle. The gun has been operated with 4 mm diameter polyurethane foam pellets (density = 0.14 g/cm 3 ), a 40 cm-long barrel, and various gas propellants at pressures exceeding 70 bar. At I/sub arc/ = 1 kA, V/sub arc/ = 200 V, with helium propellant, the arc produces a 2 to 3 fold prompt increase in P/sub breech/ and a delayed increase in P/sub muzzle/; the pellets exit the gun from 0.5 to 1.0 ms earlier than with the gas alone at 40% higher speeds. Comparisons with the so-called ideal gun theory and with full one-dimensional hydrodynamic calculations of the pellet acceleration will be presented

  18. Studies of pellet acceleration with arc discharge heated propellants

    International Nuclear Information System (INIS)

    Schuresko, D.D.

    1986-01-01

    An arc discharge has been utilized to heat gaseous propellants in a pneumatic pellet gun. A cylindrical arc chamber is interposed between the propellant inlet valve and the gun breech and fitted with a ceramic insert for generating swirl in the incoming gas stream. The arc is initiated after the propellant valve opens and the breech pressure starts to rise; a typical discharge lasts 300 microseconds with peak currents up to 2 kA at arc voltages ranging from 100-400 V. The system is instrumented with piezoelectric pressure transducers at the propellant valve outlet, gun breech, and gun muzzle. The gun has been operated with 4 mm diameter polyurethane foam pellets (density = 0.14 g/cm 3 ), a 40 cm-long barrel, and various gas propellants at pressures exceeding 70 bar. At I/sub arc/ = 1 kA, V/sub arc/ = 200 V, with helium propellant, the arc produces a 2-3 fold prompt increase in P/sub breech/ and a delayed increase in P/sub muzzle/; the pellets exit the gun from 0.5-1.0 ms earlier than with the gas alone at 40% higher speeds. Comparisons with the so-called ideal gun theory and with full one-dimensional hydrodynamic calculations of the pellet acceleration will be presented

  19. Understanding and Predicting Gun Barrel Erosion

    National Research Council Canada - National Science Library

    Johnston, Ian A

    2005-01-01

    The Australian Defence Force will soon have to contend with gun barrel erosion issues arising from the use of new low-vulnerability gun propellants, the acquisition of new ammunition and gun systems...

  20. Density Distributions of Cyclotrimethylenetrinitramines (RDX)

    International Nuclear Information System (INIS)

    Hoffman, D M

    2002-01-01

    As part of the US Army Foreign Comparative Testing (FCT) program the density distributions of six samples of class 1 RDX were measured using the density gradient technique. This technique was used in an attempt to distinguish between RDX crystallized by a French manufacturer (designated insensitive or IRDX) from RDX manufactured at Holston Army Ammunition Plant (HAAP), the current source of RDX for Department of Defense (DoD). Two samples from different lots of French IRDX had an average density of 1.7958 ± 0.0008 g/cc. The theoretical density of a perfect RDX crystal is 1.806 g/cc. This yields 99.43% of the theoretical maximum density (TMD). For two HAAP RDX lots the average density was 1.786 ± 0.002 g/cc, only 98.89% TMD. Several other techniques were used for preliminary characterization of one lot of French IRDX and two lot of HAAP RDX. Light scattering, SEM and polarized optical microscopy (POM) showed that SNPE and Holston RDX had the appropriate particle size distribution for Class 1 RDX. High performance liquid chromatography showed quantities of HMX in HAAP RDX. French IRDX also showed a 1.1 C higher melting point compared to HAAP RDX in the differential scanning calorimetry (DSC) consistent with no melting point depression due to the HMX contaminant. A second part of the program involved characterization of Holston RDX recrystallized using the French process. After reprocessing the average density of the Holston RDX was increased to 1.7907 g/cc. Apparently HMX in RDX can act as a nucleating agent in the French RDX recrystallization process. The French IRDX contained no HMX, which is assumed to account for its higher density and narrower density distribution. Reprocessing of RDX from Holston improved the average density compared to the original Holston RDX, but the resulting HIRDX was not as dense as the original French IRDX. Recrystallized Holston IRDX crystals were much larger (3-500 (micro)m or more) then either the original class 1 HAAP RDX or French

  1. Combustion characteristics of SMX and SMX based propellants

    Science.gov (United States)

    Reese, David A.

    This work investigates the combustion of the new solid nitrate ester 2,3-hydroxymethyl-2,3-dinitro-1,4-butanediol tetranitrate (SMX, C6H 8N6O16). SMX was synthesized for the first time in 2008. It has a melting point of 85 °C and oxygen balance of 0% to CO 2, allowing it to be used as an energetic additive or oxidizer in solid propellants. In addition to its neat combustion characteristics, this work also explores the use of SMX as a potential replacement for nitroglycerin (NG) in double base gun propellants and as a replacement for ammonium perchlorate in composite rocket propellants. The physical properties, sensitivity characteristics, and combustion behaviors of neat SMX were investigated. Its combustion is stable at pressures of up to at least 27.5 MPa (n = 0.81). The observed flame structure is nearly identical to that of other double base propellant ingredients, with a primary flame attached at the surface, a thick isothermal dark zone, and a luminous secondary flame wherein final recombination reactions occur. As a result, the burning rate and primary flame structure can be modeled using existing one-dimensional steady state techniques. A zero gas-phase activation energy approximation results in a good fit between modeled and observed behavior. Additionally, SMX was considered as a replacement for nitroglycerin in a double base propellant. Thermochemical calculations indicate improved performance when compared with the common double base propellant JA2 at SMX loadings above 40 wt-%. Also, since SMX is a room temperature solid, migration may be avoided. Like other nitrate esters, SMX is susceptible to decomposition over long-term storage due to the presence of excess acid in the crystals; the addition of stabilizers (e.g., derivatives of urea) during synthesis should be sufficient to prevent this. the addition of Both unplasticized and plasticized propellants were formulated. Thermal analysis of unplasticized propellant showed a distinct melt

  2. Plasma ignition of LOVA propellants

    NARCIS (Netherlands)

    Driel, C.A. van; Boluijt, A.G.; Schilt, A.

    2010-01-01

    Ignition experiments were performed using a gun simulator which is equipped with a burst disk. This equipment facilitates the application of propellant loading densities which are comparable to those applied in regular ammunitions. For this study the gun simulator was equipped with a plasma jet

  3. Comparison of the characteristics of granular propellant movement in interior ballistics based on the interphase drag model

    International Nuclear Information System (INIS)

    Jang, Jin Sung; Oh, Seok Hawn; Roh, Tae Seong

    2014-01-01

    Interior ballistics are completed in tens of milliseconds, as are all gun-firing phenomena. Thus, some data cannot be measured directly through experimentation. Therefore, such complex gun-firing phenomena are traditionally clarified by numerical analysis. In the two phase flow of interior ballistics, interphase drag has a strong effect on propellant particle movement. This drag is a momentum sink in the gas phase and a corresponding source of momentum for the solid phase. Previous studies have calculated the drag force on the propellant particles using Ergun's empirical equation, which was developed for a dense bed and relates the drag to the pressure drop through porous media. However, the particulate bed is fluidized in the course of the cycle of interior ballistics, thus indicating that the flow field is ransient with regions of high Reynolds number beyond the range of experimental data. The Ergun equation is examined through a compensation study and calibrated based on the Reynolds number using the numerical method. Moreover, the influence of different drag models on flow behavior and propellant movement in interior ballistics is analyzed.

  4. A Portable Burn Pan for the Disposal of Excess Propellants

    Science.gov (United States)

    2016-06-01

    2013 - 06/01/2016 A Portable Burn Pan for the Disposal of Excess Propellants Michael Walsh USA CRREL USA CRREL 72 Lyme Road Hanover, NH 03755...Army Alaska XRF X-Ray Florescence vii ACKNOWLEDGEMENTS Project ER-201323, A Portable Burn Pan for the Disposal of Gun Propellants, was a very...contamination problem while allowing troops to train as they fight, we have developed a portable training device for burning excess gun propellants. 1.1

  5. Diagnostics of Gun Barrel Propellants

    National Research Council Canada - National Science Library

    Lederman, S

    1983-01-01

    A preliminary investigation of the applicability of the spontaneous Raman diagnostic technique to the determination of the temperature of the propellant gases in the vicinity of the muzzle of a 2Omm...

  6. Electrostaticspray preparation and properties of RDX/DOS composites

    Directory of Open Access Journals (Sweden)

    Jian Yao

    2017-08-01

    Full Text Available A composite explosive based on 1, 3, 5-trinitro-1, 3, 5-triazinane (RDX was prepared by electrostaticspray method with dioctyl sebacate (DOS as desensitizer. After preparation, the particle size and crystal structure were characterized and chemical features, such as chemical bonds, functional groups, thermal decomposition parameters and mechanical sensitivity were investigated as well. In terms of the morphologies of the composites, the particle sizes were in the range of 1–3 μm. Compared with RDX, the crystal types, chemical bonds and functional groups of the RDX/DOS composites were unchanged. The activation energy of the composites was lower than that of raw RDX, and the 3wt % DOS composites had the lowest activation energy. The impact sensitivity and friction sensitivity of the RDX/DOS composites were lower than those of raw RDX, and the 10wt% DOS composites had the highest H50 (125.9 cm and the lowest friction sensitivity (8%.

  7. Non-equilibrium dynamics due to moving deflagration front at RDX/HTPB interface

    Science.gov (United States)

    Chaudhuri, Santanu; Joshi, Kaushik; Lacevic, Naida

    Reactive dissipative particle dynamics (DPD-RX), a promising tool in characterizing the sensitivity and performance of heterogeneous solid propellants like polymer bonded explosives (PSXs), requires further testing for non-equilibrium dynamics. It is important to understand detailed atomistic chemistry for developing coarse grain reactive models needed for the DPD-RX. In order to obtain insights into combustion chemistry of RDX/HTPB binder, we used reactive molecular dynamics (RMD) to obtain energy up-pumping and reaction mechanisms at RDX/HTPB interface when exposed to a self-sustaining deflagration front. Hot spots are ignited near and away from the heterogeneous interface using the thermal pulse. The results show that the hot spot near interface significantly delays the transition from ignition to deflagration. We will present the mechanical response and the combustion chemistry of HTPB when the propagating deflagration front hits the polymer binder. We will discuss our efforts to incorporate this RMD based chemistry into the DPD-RX which will enable us to perform such non-equilibrium dynamics simulations on large-length scale with microstructural heterogeneities. Funding from DTRA Grant Number HDTRA1-15-1-0034 is acknowledged.

  8. The electromagnetic rocket gun impact fusion driver

    International Nuclear Information System (INIS)

    Winterberg, F.

    1984-01-01

    A macroparticle accelerator to be used as an impact fusion driver is discussed and which can accelerate a small projectile to --200 km/sec over a distance of a few 100 meters. The driver which we have named electromagnetic rocket gun, accelerates a small rocket-like projectile by a travelling magnetic wave. The rocket propellant not only serves as a sink to absorb the heat produced in the projectile by resistive energy losses, but at the same time is also the source of additional thrust through the heating of the propellant to high temperatures by the travelling magnetic wave. The total thrust on the projectile is the sum of the magnetic and recoil forces. In comparison to a rocket, the efficiency is here much larger, with the momentum transferred to the gun barrel of the gun rather than to a tenuous jet. (author)

  9. Electromagnetic compression gun for hypervelocity projectile acceleration

    International Nuclear Information System (INIS)

    Woo, J.T.

    1987-01-01

    The rapid acceleration of projectiles to very high velocities has applications in many areas. The general requirements for an effective system is simplicity, reliability, compactness and good efficiency. The authors developed a concept by using electromagnetic forces to compressionally heat a plasma to high temperature and pressure to serve as the propellant for the acceleration of projectiles. The concept shares the simplicity of the light gas gun, but because of the high temperature of the propellant, is capable of significantly higher performance. Unlike the electrothermal gun approach to raise the propellant temperature by resistive heating, the electromagnetic concept is more efficient at higher temperatures. Operationally, the concept resembles a railgun in requiring a large pulsed current to drive the system. However, the current flow in this case is entirely external to the gun barrel and is axisymmetric. Therefore, many of the problems associated with railgun operations are avoided. Furthermore, because the current channel is external, there is also greater flexibility in the choice of load impedance to match to the power supply. The concept can also be generalized to a multi-stage regenerative system driven by a pulse forming network to resemble a coaxial accelerator

  10. Formulation development and characterization of cellulose acetate nitrate based propellants for improved insensitive munitions properties

    Directory of Open Access Journals (Sweden)

    Thelma Manning

    2014-06-01

    Full Text Available Cellulose acetate nitrate (CAN was used as an insensitive energetic binder to improve the insensitive munitions (IM properties of gun propellants to replace the M1 propellant used in 105 mm artillery charges. CAN contains the energetic nitro groups found in nitrocellulose (NC, but also acetyl functionalities, which lowered the polymer's sensitivity to heat and shock, and therefore improved its IM properties relative to NC. The formulation, development and small-scale characterization testing of several CAN-based propellants were done. The formulations, using insensitive energetic solid fillers and high-nitrogen modifiers in place of nitramine were completed. The small scale characterization testing, such as closed bomb testing, small scale sensitivity, thermal stability, and chemical compatibility were done. The mechanical response of the propellants under high-rate uni-axial compression at, hot, cold, and ambient temperatures were also completed. Critical diameter testing, hot fragment conductive ignition (HFCI tests were done to evaluate the propellants' responses to thermal and shock stimuli. Utilizing the propellant chemical composition, theoretical predictions of erosivity were completed. All the small scale test results were utilized to down-select the promising CAN based formulations for large scale demonstration testing such as the ballistic performance and fragment impact testing in the 105 mm M67 artillery charge configurations. The test results completed in the small and large scale testing are discussed.

  11. Investigation on utilization of liquid propellant in ballistic range experiments

    Energy Technology Data Exchange (ETDEWEB)

    Saso, Akihiro; Oba, Shinji; Takayama, Kazuyoshi [Tohoku University, Sendai (Japan)

    1999-10-31

    Experiments were conducted in a ballistic range using a HAN (hydroxylammonium nitrate)-based liquid monopropellant, LP1846. In a 25-mm-bore single-stage gun, using bulk-loaded propellant of 10 to 35 g, a muzzle speed up to 1.0 km/s was obtained. Time variations of propellant chamber pressures and in-tube projectile velocity profiles were measured. The liquid propellant combustion was initiated accompanying a delay time which was created due to the pyrolysis of the propellant. In order to obtain reliable ballistic range performance, the method of propellant loading was revealed to be critical. Since the burning rate of the liquid propellant is relatively low, the peak acceleration and the muzzle speed strongly depend on the rupture pressure of a diaphragm that was inserted between the launch tube and the propellant chamber. (author)

  12. Electro Thermal Chemical Gun Technology Study

    National Research Council Canada - National Science Library

    Diamond, P

    1999-01-01

    .... Michael Stroscio. Electro Thermal Chemical (ETC) gun technology refers to the use of plasma devices in place of traditional chemical ignitors to initiate the burning of high energy propellants in a controlled manner...

  13. Analysis of RDX and RDX Breakdown Products in Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Felt, Deborah R.; Larson, Steven L.; Wani, Altaf; Davis, Jeffrey L.

    2003-03-26

    The identification and quantification of explosives and their degradation products in soil and natural waters is helpful in the design of remediation technologies, mobility investigations and performing risk assessments. The objective of this study was to develop a method for the determination of the degradation of nitramine compounds, specifically hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). The analytical methods developed in this study were based on reversed-phase high performance liquid chromatography (HPLC) using both C-18 and CN bonded silica columns to eliminate common interferences. Contaminant identification was further confirmed by performing spectral analysis of the compounds upon elution. The proposed method yields good separation of RDX from its degradation products and from other common energetic compounds. Method detection limits for the proposed method ranged from 0.01 to 0.03 mg/L. This method satisfies the need for analytical techniques to monitor the formation and subsequent degradation products of toxic and carcinogenic nitrosyl substituted nitramines.

  14. On the mechanism of energy transfer in the plasma-propellant interaction

    Energy Technology Data Exchange (ETDEWEB)

    Porwitzky, Andrew J.; Keidar, Michael; Boyd, Iain D. [University of Michigan, Department of Aerospace Engineering, Ann Arbor, Michigan 48109-2140 (United States)

    2007-10-15

    A coupled plasma sheath/ablation model is developed for electrothermal chemical gun applications. By combining a commonly employed collisional sheath model with a previous ablation model, the convective heat flux as a function of time to the propellant bed is determined for two potential electrothermal chemical gun propellants, XM39 and JA2. It is found that the convective heat flux varies smoothly from a nearly collisionless to a fully collisional regime over the short duration of the plasma pulse. The possibility of determining an accurate estimate of the amount of heat flux to the propellant bed due to radiation from the bulk plasma presents itself. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  15. Effect of Nano-Magnesium Hydride on the Thermal Decomposition Behaviors of RDX

    International Nuclear Information System (INIS)

    Yao, M.; Chen, L.; Rao, G.; Peng, J.; Zou, J.; Zeng, X.

    2013-01-01

    In order to improve the detonation performance of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) explosive, addictive with high heat values were used, and magnesium hydride (MgH 2 ) is one of the candidates. However, it is important to see whether MgH 2 is a safe addictive. In this paper, the thermal and kinetic properties of RDX and mixture of RDX/MgH 2 were investigated by differential scanning calorimeter (DSC) and accelerating rate calorimeter (ARC), respectively. The apparent activation energy (E) and frequency factor (A) of thermal explosion were calculated based on the data of DSC experiments using the Kissinger and Ozawa approaches. The results show that the addition of MgH 2 decreases both E and A of RDX, which means that the mixture of RDX/MgH 2 has a lower thermal stability than RDX, and the calculation results obtained from the ARC experiments data support this too. Besides, the most probable mechanism functions about the decomposition of RDX and RDX/MgH 2 were given in this paper which confirmed the change of the decomposition mechanism.

  16. Relationship between RDX properties and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Doherty, Ruth M. [Research, Development, Test and Evaluation Directorate, Naval Surface Warfare Center Indian Head Division, Indian Head, MD 20640-5102 (United States); Watt, Duncan S. [Novare, Level 6 80 Petrie Terrace, Brisbane 4000 (Australia)

    2008-02-15

    An interlaboratory comparison of seven lots of commercially available RDX was conducted to determine what properties of the nitramine particles can be used to assess whether the RDX has relatively high or relatively low sensitivity. The materials chosen for the study were selected to give a range of HMX content, manufacturing process and reported shock sensitivity. The results of two different shock sensitivity tests conducted on a PBX made with the RDX lots in the study showed that there are measurable differences in the shock sensitivity of the PBXs, but the impact sensitivity for all of the lots is essentially the same. Impact sensitivity is not a good predictor of shock sensitivity for these types of RDX. Although most RDX that exhibits RS has low HMX content, that characteristic alone is not sufficient to guarantee low sensitivity. A range of additional analytical chemistry tests were conducted on the material; two of these (HPLC and DSC) are discussed within. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  17. Preparation and characterization of GA/RDX nanostructured ...

    Indian Academy of Sciences (India)

    Thenhexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was added and trapped in the nano-porous three-dimensional networks of GA to obtain a novel GA/RDX nanostructured energetic composite. The composition, morphology andstructure of the obtained GA/RDX nanostructured energetic composite were characterized by ...

  18. High Brightness Injectors Based On Photocathode DC Gun

    International Nuclear Information System (INIS)

    B. Yunn

    2001-01-01

    Sample results of new injector design method based on a photocathode dc gun are presented, based on other work analytically proving the validity of the emittance compensation scheme for the case even when beam bunching is involved. We have designed several new injectors appropriate for different bunch charge ranges accordingly. Excellent beam quality produced by these injectors clearly shows that a photocathode dc gun can compete with a rf gun on an equal footing as the source of an electron beam for the bunch charge ranging up to 2 nano Coulomb (nC). This work therefore elevates a dc gun based injector to the preferred choice for many ongoing high brightness accelerator projects considering the proven operational stability and high average power capability of the dc gun

  19. Treatment of HMX and RDX contamination

    International Nuclear Information System (INIS)

    Card, R.E. Jr.; Autenrieth, R.

    1998-03-01

    HMX and RDX are often found in the soil, groundwater, and surface waters at facilities where they are manufactured as the result of negligent disposal methods. The toxicity of these compounds and their degradation products has led to concern about their fate in the environment and the potential for human exposure. HMX and RDX are recalcitrant in the environment with low rates of biodegradation and photolysis. Several methods of treating contaminated soils and waters have been developed and studied. Many of these technologies (i.e., carbon adsorption, oxidation, and chemical treatment) have been developed to treat munition plant wastewaters that are contaminated with explosives. These methods need to be adapted to remediate contaminated water. Other technologies such as bioremediation and composting are being developed as methods of remediating HMX and RDX contamination in a solid matrix. This report describes and evaluates each of these technologies. This report also describes the processes which affect HMX and RDX in the environment. The major transformation processes of RDX and HMX in the environment are biodegradation and photolysis. A major factor affecting the transport and treatment of RDX and HMX in soil-water environments is their sorption and desorption to soil particles. Finally, this report draws conclusions as to which treatment methods are currently most suitable for the remediation of contaminated soils and waters

  20. Development of Biomarkers for Assessing In Situ RDX Biodegradation Potential

    Science.gov (United States)

    2016-06-10

    the RDX degrading communities in four different soil slurries. The third task examined the microorganisms involved in RDX biodegradation from...RDX biodegradation at two Navy sites. Several key microorganisms were associated with RDX removal in these mixed communities. These phylogenetic and...manuscripts. 1 ABSTRACT Objective The objective was to identify the microorganisms and genes responsible for the biodegradation of RDX (hexahydro

  1. Development of HAN-based Liquid Propellant Thruster

    Science.gov (United States)

    Hisatsune, K.; Izumi, J.; Tsutaya, H.; Furukawa, K.

    2004-10-01

    Many of propellants that are applied to the conventional spacecraft propulsion system are toxic propellants. Because of its toxicity, considering the environmental pollution or safety on handling, it will be necessary to apply the "green" propellant to the spacecraft propulsion system. The purpose of this study is to apply HAN based liquid propellant (LP1846) to mono propellant thruster. Compared to the hydrazine that is used in conventional mono propellant thruster, HAN based propellant is not only lower toxic but also can obtain higher specific impulse. Moreover, HAN based propellant can be decomposed by the catalyst. It means there are the possibility of applying to the mono propellant thruster that can leads to the high reliability of the propulsion system.[1],[2] However, there are two technical subjects, to apply HAN based propellant to the mono propellant thruster. One is the high combustion temperature. The catalyst will be damaged under high temperature condition. The other is the low catalytic activity. It is the serious problem on application of HAN based propellant to the mono propellant thruster that is used for attitude control of spacecraft. To improve the catalytic activity of HAN based propellant, it is necessary to screen the best catalyst for HAN based propellant. The adsorption analysis is conducted by Monte Carlo Simulation to screen the catalyst metal for HAN and TEAN. The result of analysis shows the Iridium is the best catalyst metal for HAN and TEAN. Iridium is the catalyst metal that is used at conventional mono propellant thruster catalyst Shell405. Then, to confirm the result of analysis, the reaction test about catalyst is conducted. The result of this test is the same as the result of adsorption analysis. That means the adsorption analysis is effective in screening the catalyst metal. At the evaluating test, the various types of carrier of catalyst are also compared to Shell 405 to improve catalytic activity. The test result shows the

  2. Spectrophotometric determination of cyclotrimethylenetrinitramine (RDX) in explosive mixtures and residues with the Berthelot reaction.

    Science.gov (United States)

    Uzer, A; Erçağ, E; Apak, R

    2008-03-31

    On-site colorimetric methods are a valuable, cost-effective tool to assess the nature and extent of contamination in remediated sites and to enable on-site screening for police criminology laboratories. The existing colorimetric method for cyclotrimethylenetrinitramine (RDX) based on a Griess reaction suffers from the non-quantitative reduction to nitrite and from the unstable character of HNO2 in acidic medium. Thus we propose a novel spectrophotometric RDX assay in explosive mixtures and residues, based on (Zn+HCl) reduction of RDX in a microwave oven, followed by neutralization of the reduction products to ammonia and low molecular-weight amines, and Berthelot reaction of these amine-compounds with phenol and hypochlorite in alkaline medium to give an intensely blue indophenol dye absorbing at 631nm. The molar absorptivity and limit of detection (LOD) for RDX were (1.08+/-0.04)x10(4) L mol(-1) cm(-1) and 0.18 mg L(-1), respectively. Application of the method to synthetic mixture solutions of RDX and trinitrotoluene (TNT) at varying proportions showed that there was minimal interference from TNT (which could be compensated for by dicyclohexylamine colorimetry), since the Berthelot reaction was essentially non-responsive to m-substituted anilines derived from TNT upon (Zn+HCl) reduction. The proposed method was successfully applied to military-purpose explosive mixtures of (RDX+inert matter) such as Comp A5, Comp C4, and Hexal P30, and to (RDX+TNT) mixtures such as Comp B. The molar absorptivity of RDX was much higher than that of either ammonium or nitrate; RDX could be effectively separated from ammonium and nitrate in soil mixtures, based on solubility differences. The Berthelot method for RDX was statistically validated using Comp B mixtures against standard HPLC equipped with a Hypersil C-18 column with (40% MeOH-60% H2O) mobile phase, and against gas chromatography-thermal energy analysis (GC-TEA) system.

  3. Shock-to-detonation transition of RDX, HMX and NTO based composite high explosives: experiments and modelling

    International Nuclear Information System (INIS)

    Baudin, G; Roudot, M; Genetier, M; Mateille, P; Lefrançois, A

    2014-01-01

    HMX, RDX and NTO based cast-cured plastic bounded explosive (PBX) are widely used in insensitive ammunitions. Designing modern warheads needs robust and reliable models to compute shock ignition and detonation propagation inside PBX. Comparing to a pressed PBX, a cast-cured PBX is not porous and the hot-spots are mainly located at the grain-binder interface leading to a different burning behavior during shock-to-detonation transition. Here, we review the shock-to-detonation transition (SDT) and its modeling for cast-cured PBX containing HMX, RDX and NTO. Future direction is given in conclusion.

  4. Shock-to-detonation transition of RDX, HMX and NTO based composite high explosives: experiments and modelling

    Science.gov (United States)

    Baudin, G.; Roudot, M.; Genetier, M.; Mateille, P.; Lefrançois, A.

    2014-05-01

    HMX, RDX and NTO based cast-cured plastic bounded explosive (PBX) are widely used in insensitive ammunitions. Designing modern warheads needs robust and reliable models to compute shock ignition and detonation propagation inside PBX. Comparing to a pressed PBX, a cast-cured PBX is not porous and the hot-spots are mainly located at the grain-binder interface leading to a different burning behavior during shock-to-detonation transition. Here, we review the shock-to-detonation transition (SDT) and its modeling for cast-cured PBX containing HMX, RDX and NTO. Future direction is given in conclusion.

  5. Development process of muzzle flows including a gun-launched missile

    Directory of Open Access Journals (Sweden)

    Zhuo Changfei

    2015-04-01

    Full Text Available Numerical investigations on the launch process of a gun-launched missile from the muzzle of a cannon to the free-flight stage have been performed in this paper. The dynamic overlapped grids approach are applied to dealing with the problems of a moving gun-launched missile. The high-resolution upwind scheme (AUSMPW+ and the detailed reaction kinetics model are adopted to solve the chemical non-equilibrium Euler equations for dynamic grids. The development process and flow field structure of muzzle flows including a gun-launched missile are discussed in detail. This present numerical study confirms that complicated transient phenomena exist in the shortly launching stages when the gun-launched missile moves from the muzzle of a cannon to the free-flight stage. The propellant gas flows, the initial environmental ambient air flows and the moving missile mutually couple and interact. A complete structure of flow field is formed at the launching stages, including the blast wave, base shock, reflected shock, incident shock, shear layer, primary vortex ring and triple point.

  6. Beam-Based Procedures for RF Guns

    CERN Document Server

    Krasilnikov, Mikhail; Grabosch, H J; Hartrott, Michael; Hui Han, Jang; Miltchev, Velizar; Oppelt, Anne; Petrosyan, Bagrat; Staykov, Lazar; Stephan, Frank

    2005-01-01

    A wide range of rf photo injector parameters has to be optimized in order to achieve an electron source performance as required for linac based high gain FELs. Some of the machine parameters can not be precisely controlled by direct measurements, whereas the tolerance on them is extremely tight. Therefore, this should be met with beam-based techniques. Procedures for beam-based alignment (BBA) of the laser on the photo cathode as well as solenoid alignment have been developed. They were applied at the Photo Injector Test facility at DESY Zeuthen (PITZ) and at the photo injector of the VUV-FEL at DESY Hamburg. A field balance of the accelerating mode in the 1 ½ cell gun cavity is one of the key beam dynamics issues of the rf gun. Since no direct field measurement in the half and full cell of the cavity is available for the PITZ gun, a beam-based technique to determine the field balance has been proposed. A beam-based rf phase monitoring procedure has been developed as well.

  7. Gun possession among American youth: a discovery-based approach to understand gun violence.

    Science.gov (United States)

    Ruggles, Kelly V; Rajan, Sonali

    2014-01-01

    To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions' Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001-2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association "fingerprint" to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described.

  8. Gun possession among American youth: a discovery-based approach to understand gun violence.

    Directory of Open Access Journals (Sweden)

    Kelly V Ruggles

    Full Text Available OBJECTIVE: To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions' Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. RESULTS: Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001-2011. Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association "fingerprint" to 1 visualize and assess which behaviors frequently co-occur and 2 evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1 physical activity and nutrition; 2 disordered eating, suicide and sexual violence; 3 weapon carrying and physical safety; 4 alcohol, marijuana and cigarette use; 5 drug use on school property and 6 overall drug use. CONCLUSIONS: Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described.

  9. Application of 13C-stable isotope probing to identify RDX-degrading microorganisms in groundwater

    International Nuclear Information System (INIS)

    Cho, Kun-Ching; Lee, Do Gyun; Roh, HyungKeun; Fuller, Mark E.; Hatzinger, Paul B.; Chu, Kung-Hui

    2013-01-01

    We employed stable isotope probing (SIP) with 13 C-labeled hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) to identify active microorganisms responsible for RDX biodegradation in groundwater microcosms. Sixteen different 16S rRNA gene sequences were derived from microcosms receiving 13 C-labeled RDX, suggesting the presence of microorganisms able to incorporate carbon from RDX or its breakdown products. The clones, residing in Bacteroidia, Clostridia, α-, β- and δ-Proteobacteria, and Spirochaetes, were different from previously described RDX degraders. A parallel set of microcosms was amended with cheese whey and RDX to evaluate the influence of this co-substrate on the RDX-degrading microbial community. Cheese whey stimulated RDX biotransformation, altered the types of RDX-degrading bacteria, and decreased microbial community diversity. Results of this study suggest that RDX-degrading microorganisms in groundwater are more phylogenetically diverse than what has been inferred from studies with RDX-degrading isolates. Highlights: •SIP identified sixteen groundwater bacteria capable of using RDX and/or its metabolites as a carbon source. •The RDX degraders in groundwater are phylogenetically diverse and different from known RDX degraders. •Cheese whey induced community shift and altered diversity of the RDX-degrading microorganisms over time. -- RDX-degrading bacteria in contaminated groundwater, identified by SIP with 13 C-labeled RDX, are phylogenetically diverse and different from known RDX degraders

  10. Definition of a JA2 equivalent propellant to be produced by continuous solvent-less extrusion

    NARCIS (Netherlands)

    Manning, T.G.; Leone, J.; Zebregs, M.; Ramlal, D.R.; Driel, C.A. van

    2013-01-01

    The aim of this work is to demonstrate the manufacturing of a propellant by solvent-less continuous twin screw extrusion processing while maintaining gun performance characteristics of conventional JA-2 propellant. This is elucidated by explicitly researching the relationship between interior

  11. Bioconcentration of TNT and RDX in coastal marine biota.

    Science.gov (United States)

    Ballentine, Mark; Tobias, Craig; Vlahos, Penny; Smith, Richard; Cooper, Christopher

    2015-05-01

    The bioconcentration factor (BCF) was measured for 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in seven different marine species of varying trophic levels. Time series and concentration gradient treatments were used for water column and tissue concentrations of TNT, RDX, and their environmentally important derivatives 2-amino-4,6-dintrotoluene (2-ADNT) and 4-amino-2,6-dinitrotoluene (4-ADNT). BCF values ranged from 0.0031 to 484.5 mL g(-1) for TNT and 0.023 to 54.83 mL g(-1) for RDX. The use of log K ow value as an indicator was evaluated by adding marine data from this study to previously published data. For the munitions in this study, log K ow value was a good indicator in the marine environment. The initial uptake and elimination rates of TNT and RDX for Fucus vesiculosus were 1.79 and 0.24 h(-1) for TNT and 0.50 and 0.0035 h(-1) for RDX respectively. Biotransformation was observed in all biota for both TNT and RDX. Biotransformation of TNT favored 4-ADNT over 2-ADNT at ratios of 2:1 for F. vesiculosus and 3:1 for Mytilus edulis. Although RDX derivatives were measureable, the ratios of RDX derivatives were variable with no detectable trend. Previous approaches for measuring BCF in freshwater systems compare favorably with these experiments with marine biota, yet significant gaps on the ultimate fate of munitions within the biota exist that may be overcome with the use stable isotope-labeled munitions substrates.

  12. Karakteristike trzanja elektromagnetskog topa / Recoil characteristics of an electromagnetic rail gun

    Directory of Open Access Journals (Sweden)

    Zoran B. Ristić

    2009-10-01

    Full Text Available U radu je razmatrano trzanje elektromagnetskog šinskog topa i upoređeno sa trzanjem konvencionalnog topa sa barutnim punjenjem. Zaključuje se da je kod elektromagnetskog topa trzanje manje nego kod topa sa barutnim punjenjem. Takođe, pokazano je da pri istim uslovima lansiranja upotreba gasne kočnice topa sa barutnim punjenjem može izmeniti karakteristike trzanja i više ih približiti ponašanju elektromagnetskog topa. / In this paper the electromagnetic rail gun recoil is discussed and compared with the recoil of a conventional, propellant gas driven gun. It is shown that, under similar launch conditions, the recoil of an electromagnetic gun is weaker than that of the powder-driven gun. The use of a muzzle brake on a powder-driven gun can alter its recoil characteristics and make its behavior closer to that of the electromagnetic rail gun.

  13. Structural Loading Statistics of Live Gun Firings for the Army's Excalibur Projectile

    National Research Council Canada - National Science Library

    Cordes, Jennifer; Vega, Julio; Carlucci, Donald E; Chaplin, Raymond; Peterson, W. S

    2005-01-01

    .... During development, Excalibur was gun-fired using a variety of propellant charges. The purpose of the tests was to determine the reliability, structural integrity, and performance for different field charges...

  14. A light-gas gun for acceleration of pellets of solid D2

    International Nuclear Information System (INIS)

    Nordskov, A.; Skovgaard, H.; Soerensen, H.; Weisberg, K.V.

    1980-10-01

    A gun has been designed and built to be used for injecting solid D 2 pellets into a small tokamak for pellet-plasma interaction studies. The pellets are formed and accelerated at temperatures close to those of liquid helium. They are propelled with pressurised H 2 -gas; the pressure arises when a quantity of solid H 2 placed in the gun barrel behind the pellet is pulse heated. Pellet velocities up to 240 m/s have been obtained. The directional accuracy is better than 0.2deg and the repetition rate is one firing every five minutes. The pellet volume is 0.6 mm 3 (2 x 10 19 molecules) while the quantity of propeller gas used is around 12 x 10 19 molecules. (author)

  15. Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) degradation by Acetobacterium paludosum.

    Science.gov (United States)

    Sherburne, Leslie A; Shrout, Joshua D; Alvarez, Pedro J J

    2005-12-01

    Substrates and nutrients are often added to contaminated soil or groundwater to enhance bioremediation. Nevertheless, this practice may be counterproductive in some cases where nutrient addition might relieve selective pressure for pollutant biodegradation. Batch experiments with a homoacetogenic pure culture of Acetobacterium paludosum showed that anaerobic RDX degradation is the fastest when auxiliary growth substrates (yeast extract plus fructose) and nitrogen sources (ammonium) are not added. This bacterium degraded RDX faster under autotrophic (H2-fed) than under heterotrophic conditions, even though heterotrophic growth was faster. The inhibitory effect of ammonium is postulated to be due to the repression of enzymes that initiate RDX degradation by reducing its nitro groups, based on the known fact that ammonia represses nitrate and nitrite reductases. This observation suggests that the absence of easily assimilated nitrogen sources, such as ammonium, enhances RDX degradation. Although specific end products of RDX degradation were not determined, the production of nitrous oxide (N2O) suggests that A. paludosum cleaved the triazine ring.

  16. Characterization of atmospheric emissions produced by live gun firing : test on the M777 155 mm Howitzer

    Energy Technology Data Exchange (ETDEWEB)

    Quemarais, B. [Defence Research and Development Canada, Toronto, ON (Canada); Diaz, E.; Poulin, I.; Marois, A. [Defence Research and Development Canada, Valcartier, PQ (Canada)

    2007-10-15

    This study analyzed the atmospheric emissions produced by the live firing of a 155 mm Howitzer gun. The study was conducted during a live firing training exercise at a Canadian Forces Base. Air emissions were sampled continuously for 3 hours. Particles and chemicals were accumulated on sampling media during the firing of 69 rounds. A single round was fired using 4 bags of propellants, and an additional 3 rounds were fired using 5 bags of propellant. Samples included particulate matter; hydrogen cyanide; polycyclic aromatic hydrocarbons (PAHs); dinitrotoluene compounds; benzene; toluene; ethylbenzene; xylene; metals; aldehydes; nitric acid; nitric oxide; nitrogen dioxide; hydrogen sulphide; and sulphur dioxide. Samples were collected at 8 m to the left of the gun as well as at 22 m in front of the gun muzzle in the line of fire. Results of the study showed that 60 per cent of the particles were below 10 {mu}m. Formaldehyde concentrations of 7.1 and 3.6 {mu}g/m{sup 3} for the left and front sampling locations were also detected. It was concluded that live firing may pose health risks to artillery soldiers. 26 refs., 9 tabs., 7 figs.

  17. Investigation of pellet acceleration by an arc heated gas gun

    International Nuclear Information System (INIS)

    Andersen, P.; Andersen, S.A.; Bundgaard, J.; Baekmark, L.; Hansen, B.H.; Jensen, V.O.; Kossek, H.; Michelsen, P.K.; Nordskov, A.; Sass, B.; Soerensen, H.; Weisberg, K.V.

    1987-06-01

    This report describes work on pellet acceleration by means of an arc heated gas gun. The work is a continuation of the work described in RISO-M-2536. The aim of the work is to obtain velocities well above 2 km/s for 3.2 mm diameter deuterium pellets. By means of a cryogenic arc chamber in which the hydrogen propellant is pre-condensed, extruded deutetrium pellets are accelerated up to a maximum velocity of 1.93 km/s. When increasing the energy input to the arc in order to increase the pellet velocity further the heat input to the extrusion/punching pellet loading mechanism was found to be critical: preparation of pellets became difficult and cooling times between shots became inconveniently long. In order to circumvent this problems the concept of a room temperature hydrogen propellant pellet fed arc chamber was proposed. Preliminary results from acceleration of polyurethane pellets with this arc chamber are described as well as the work of developing of feed pellet guns for this chamber. Finally the report describes design consideration for a high pressure propellant pellet fed arc chamber together with preliminary results obtained with a proto-type arc chamber. (author)

  18. Tracking the Fate of Explosive-Trinitrotriazine (RDX) in Coastal Marine Ecosystems Using Stable Isotopic Tracer

    Science.gov (United States)

    Ariyarathna, T. S.; Ballentine, M.; Vlahos, P.; Smith, R. W.; Bohlke, J. K.; Tobias, C. R.; Fallis, S.; Groshens, T.; Cooper, C.

    2017-12-01

    It has been estimated that there are hundreds of explosive-contaminated sites all over the world and managing these contaminated sites is an international challenge. As coastal zones and estuaries are commonly impacted zones, it is vital to understand the fate and transport of munition compounds in these environments. The demand for data on sorption, biodegradation and mineralization of trinitrotriazine (RDX) in coastal ecosystems is the impetus for this study using stable nitrogen isotopes to track its metabolic pathways. Mesocosm experiments representing subtidal vegetated, subtidal unvegetated and intertidal marsh ecocosms were conducted. Steady state concentrations of RDX were maintained in the systems throughout two-week time duration of experiments. Sediment, pore-water and overlying water samples were analyzed for RDX and degradation products. Isotope analysis of the bulk sediments revealed an initial rising inventory of 15N followed by a decay illustrating the role of sediments on sorption and degradation of RDX in anaerobic sediments respectively. Both pore-water and overlying water samples were analyzed for 15N inventories of different inorganic nitrogen pools including ammonium, nitrate, nitrite, nitrous oxide and nitrogen gases. RDX is mineralized to nitrogen gas through a series of intermediates leaving nitrous oxide as the prominent metabolite of RDX. Significant differences in RDX metabolism were observed in the three different ecosystems based on sediment characteristics and redox conditions in the systems. Fine grained organic carbon rich sediments show notably higher mineralization rates of RDX in terms of production of its metabolites. Quantification of degradation and transformation rates leads to mass balances of RDX in the systems. Further analysis of results provides insights for mineralization pathways of RDX into both organic and inorganic nitrogen pools entering the marine nitrogen cycle.

  19. Microwave Dielectric Properties of XM46 and a Surrogate Liquid Propellant

    National Research Council Canada - National Science Library

    Bossoli, Robert

    1998-01-01

    .... The dielectric constant (permittivity) of LP was determined in support of possible studies of the feasibility of using microwave energy to preheat LP for more consistent electric ignition in regenerative liquid propellant guns (RLPG...

  20. Characterization of the Morphology of RDX Particles Formed by Laser Ablation

    Science.gov (United States)

    2012-02-01

    military-grade RDX can contain significant amounts of HMX (up to 5% for type-I RDX produced by direct nitration with the Woolwich process and up to...potentially produce RDX particles with specific morphologies in support of microstructural experiments for the Multiscale Response of Energetic

  1. Field Test Kit for Gun Residue Detection; TOPICAL

    International Nuclear Information System (INIS)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue

  2. 46th Annual Gun and Missile Systems Conference and Exhibition. Volume 3 - Thursday

    Science.gov (United States)

    2011-09-01

    Coated Propellants Dr. Thelma Manning , U.S. Army RDECOM-ARDEC 11829 - Investment Cast Titanium in Gun and Missile Systems Mr. Chris Jensen, Alcoa...Design on the Interior Ballistic Performance of Deterrent Coated Propellants, Dr. Thelma Manning , U.S. Army, RDECOM- ARDEC – ENERGETICS II 11867 - IM...Jeff Siewert, Arrow Tech; Ms. Shellie Clift, NSWC-Dahlgren Emerging Technologies - Systems: u Mr. Mark Serben, U.S. Army ARDEC; Mr. Joe Buzzett, GD

  3. 46th Annual Gun and Missile Systems Conference and Exhibition. Volume 2. Wednesday

    Science.gov (United States)

    2011-09-01

    Coated Propellants Dr. Thelma Manning , U.S. Army RDECOM-ARDEC 11829 - Investment Cast Titanium in Gun and Missile Systems Mr. Chris Jensen, Alcoa...Design on the Interior Ballistic Performance of Deterrent Coated Propellants, Dr. Thelma Manning , U.S. Army, RDECOM- ARDEC – ENERGETICS II 11867 - IM...Jeff Siewert, Arrow Tech; Ms. Shellie Clift, NSWC-Dahlgren Emerging Technologies - Systems: u Mr. Mark Serben, U.S. Army ARDEC; Mr. Joe Buzzett, GD

  4. A Study of Ammunition Response to the Interior Ballistics Environment of Gun Launch

    National Research Council Canada - National Science Library

    Ray, Stephen E; Nusca, Michael J; Horst, Albert W

    2006-01-01

    ... propellant charge during gun launch. Since material stress imposed on the ammunition could potentially damage the projectile or its payload, a detailed knowledge of the peak stress is essential in the ammunition design process...

  5. Design of a Rail Gun System for Mitigating Disruptions in Fusion Reactors

    Science.gov (United States)

    Lay, Wei-Siang

    Magnetic fusion devices, such as the tokamak, that carry a large amount of current to generate the plasma confining magnetic fields have the potential to lose magnetic stability control. This can lead to a major plasma disruption, which can cause most of the stored plasma energy to be lost to localized regions on the walls, causing severe damage. This is the most important issue for the $20B ITER device (International Thermonuclear Experimental Reactor) that is under construction in France. By injecting radiative materials deep into the plasma, the plasma energy could be dispersed more evenly on the vessel surface thus mitigating the harmful consequences of a disruption. Methods currently planned for ITER rely on the slow expansion of gases to propel the radiative payloads, and they also need to be located far away from the reactor vessel, which further slows down the response time of the system. Rail guns are being developed for aerospace applications, such as for mass transfer from the surface of the moon and asteroids to low earth orbit. A miniatured version of this aerospace technology seems to be particularly well suited to meet the fast time response needs of an ITER disruption mitigation system. Mounting this device close to the reactor vessel is also possible, which substantially increases its performance because the stray magnetic fields near the vessel walls could be used to augment the rail gun generated magnetic fields. In this thesis, the potential viability on Rail Gun based DMS is studied to investigate its projected fast time response capability by design, fabrication, and experiment of an NSTX-U sized rail gun system. Material and geometry based tests are used to find the most suitable armature design for this system for which the desirable attributes are high specific stiffness and high electrical conductivity. With the best material in these studies being aluminum 7075, the experimental Electromagnetic Particle Injector (EPI) system has propelled

  6. Water quality criteria for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX)

    Energy Technology Data Exchange (ETDEWEB)

    Etnier, E.L.

    1989-04-01

    The occurrence of the munitions compound hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in groundwater surrounding Army ammunition plants may result in contamination of local drinking water supplies. RDX exerts its primary toxic effect in humans on the central nervous system, but also involves gastrointestinal and renal effects. Symptomatic effects following acute exposure include hyperirritability, nausea, vomiting, generalized epileptiform seizures, and prolonged postictal confusion and amnesia. Health effects data were analyzed for RDX, and although no controlled human studies exist concerning the acute or chronic toxic effects of exposure to RDX, sufficient animal toxicity data are available to derive an ambient water quality criterion for the protection of human health. This paper summarizes the available literature on metabolism of RDX and human and animal toxicity. Based on noncarcinogenic mammalian toxicity data, and following the methodologies of the U.S. Environmental Protection Agency, an ambient water quality criterion for the protection of human health of 103 micrograms/liter is proposed for ingestion of drinking water and aquatic foodstuffs. A criterion of 105 micrograms/liter is proposed for ingestion of drinking water alone.54 references.

  7. Identification of groundwater microorganisms capable of assimilating RDX-derived nitrogen during in-situ bioremediation

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kun-Ching [Zachry Department of Civil Engineering, Texas A& M University, College Station, TX 77843-3136 (United States); Fuller, Mark E.; Hatzinger, Paul B. [CB& I Federal Services, Lawrenceville, NJ 08648 (United States); Chu, Kung-Hui, E-mail: kchu@civil.tamu.edu [Zachry Department of Civil Engineering, Texas A& M University, College Station, TX 77843-3136 (United States)

    2016-11-01

    Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), a nitroamine explosive, is commonly detected in groundwater at military testing and training sites. The objective of this study was to characterize the microbial community capable of using nitrogen derived from the RDX or RDX intermediates during in situ bioremediation. Active groundwater microorganisms capable of utilizing nitro-, ring- or fully-labeled {sup 15}N-RDX as a nitrogen source were identified using stable isotope probing (SIP) in groundwater microcosms prepared from two wells in an aquifer previously amended with cheese whey to promote RDX biodegradation. A total of fifteen 16S rRNA gene sequences, clustered in Clostridia, β-Proteobacteria, and Spirochaetes, were derived from the {sup 15}N-labeled DNA fractions, suggesting the presence of metabolically active bacteria capable of using RDX and/or RDX intermediates as a nitrogen source. None of the derived sequences matched RDX-degrading cultures commonly studied in the laboratory, but some of these genera have previously been linked to RDX degradation in site groundwater via {sup 13}C-SIP. When additional cheese whey was added to the groundwater samples, 28 sequences grouped into Bacteroidia, Bacilli, and α-, β-, and γ-Proteobacteria were identified. The data suggest that numerous bacteria are capable of incorporating N from ring- and nitro-groups in RDX during anaerobic bioremediation, and that some genera may be involved in both C and N incorporation from RDX. - Highlights: • Cheese whey addition resulted in 28 different clones associated with RDX degradation. • The 28 clones belong to Bacteroidia, Bacilli, and α-, β-, and γ-Proteobacteria. • SIP identified 15 clones using RDX and/or its metabolites as a nitrogen source. • The clones clustered in Clostridia, β-Proteobacteria, and Spirochaetes.

  8. Identification of groundwater microorganisms capable of assimilating RDX-derived nitrogen during in-situ bioremediation

    International Nuclear Information System (INIS)

    Cho, Kun-Ching; Fuller, Mark E.; Hatzinger, Paul B.; Chu, Kung-Hui

    2016-01-01

    Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), a nitroamine explosive, is commonly detected in groundwater at military testing and training sites. The objective of this study was to characterize the microbial community capable of using nitrogen derived from the RDX or RDX intermediates during in situ bioremediation. Active groundwater microorganisms capable of utilizing nitro-, ring- or fully-labeled "1"5N-RDX as a nitrogen source were identified using stable isotope probing (SIP) in groundwater microcosms prepared from two wells in an aquifer previously amended with cheese whey to promote RDX biodegradation. A total of fifteen 16S rRNA gene sequences, clustered in Clostridia, β-Proteobacteria, and Spirochaetes, were derived from the "1"5N-labeled DNA fractions, suggesting the presence of metabolically active bacteria capable of using RDX and/or RDX intermediates as a nitrogen source. None of the derived sequences matched RDX-degrading cultures commonly studied in the laboratory, but some of these genera have previously been linked to RDX degradation in site groundwater via "1"3C-SIP. When additional cheese whey was added to the groundwater samples, 28 sequences grouped into Bacteroidia, Bacilli, and α-, β-, and γ-Proteobacteria were identified. The data suggest that numerous bacteria are capable of incorporating N from ring- and nitro-groups in RDX during anaerobic bioremediation, and that some genera may be involved in both C and N incorporation from RDX. - Highlights: • Cheese whey addition resulted in 28 different clones associated with RDX degradation. • The 28 clones belong to Bacteroidia, Bacilli, and α-, β-, and γ-Proteobacteria. • SIP identified 15 clones using RDX and/or its metabolites as a nitrogen source. • The clones clustered in Clostridia, β-Proteobacteria, and Spirochaetes

  9. Stable isotope probing reveals the importance of Comamonas and Pseudomonadaceae in RDX degradation in samples from a Navy detonation site.

    Science.gov (United States)

    Jayamani, Indumathy; Cupples, Alison M

    2015-07-01

    This study investigated the microorganisms involved in hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) degradation from a detonation area at a Navy base. Using Illumina sequencing, microbial communities were compared between the initial sample, samples following RDX degradation, and controls not amended with RDX to determine which phylotypes increased in abundance following RDX degradation. The effect of glucose on these communities was also examined. In addition, stable isotope probing (SIP) using labeled ((13)C3, (15)N3-ring) RDX was performed. Illumina sequencing revealed that several phylotypes were more abundant following RDX degradation compared to the initial soil and the no-RDX controls. For the glucose-amended samples, this trend was strong for an unclassified Pseudomonadaceae phylotype and for Comamonas. Without glucose, Acinetobacter exhibited the greatest increase following RDX degradation compared to the initial soil and no-RDX controls. Rhodococcus, a known RDX degrader, also increased in abundance following RDX degradation. For the SIP study, unclassified Pseudomonadaceae was the most abundant phylotype in the heavy fractions in both the presence and absence of glucose. In the glucose-amended heavy fractions, the 16S ribosomal RNA (rRNA) genes of Comamonas and Anaeromxyobacter were also present. Without glucose, the heavy fractions also contained the 16S rRNA genes of Azohydromonas and Rhodococcus. However, all four phylotypes were present at a much lower level compared to unclassified Pseudomonadaceae. Overall, these data indicate that unclassified Pseudomonadaceae was primarily responsible for label uptake in both treatments. This study indicates, for the first time, the importance of Comamonas for RDX removal.

  10. Treatment of RDX & HMX Plumes Using Mulch Biowalls

    Science.gov (United States)

    2008-08-01

    BAK Benzalkonium chloride BGS Below Ground Surface BRAC Base Realignment and Closure CHAAP Cornhusker Army Ammunition Plant CDPHE Colorado...Metabolism, and Reductive Transformation of RDX .............................................................. 9  Figure 4. Plan View Schematic of...43  Figure 17. Oxidation- reduction Potential (ORP) Measurement Averaged Over Different Well- rows

  11. Whose guns are stolen? The epidemiology of Gun theft victims.

    Science.gov (United States)

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2017-12-01

    Gun theft is an important source of guns used by criminals. Yet no empirical work has focused on the characteristics of gun owners that distinguish those who have had their guns stolen from those who have not. In this study, we examine the demographics and behavioral characteristics of gun owners who report having had a gun stolen. Data come from a nationally representative probability-based online survey conducted in April 2015, with a linked follow-up survey in November 2015 that asked gun owners about any theft of their guns in the past 5 years. Of 1,604 gun-owning respondents, 2.4% (95% CI 1.6,3.6) reported that one or more guns had been stolen, with a mean number of guns stolen per theft of 1.5 (95% CI 1.0,2.0]. Risk factors for having a gun stolen were owning 6 or more guns, owning guns for protection, carrying a gun in the past month, storing guns unsafely, and living in the South region of the United States. The South accounts for 37% of US households, 43% of gun owners, and two-thirds of all gun thefts. We estimate that there are approximately 250,000 gun theft incidents per year, with about 380,000 guns stolen. We find that certain types of gun owners-who own many guns, who carry guns, and who do not store guns safely-are at higher risk to have their guns stolen. Tracing data show that states in the South are exporters of crime guns used in other states. Our survey results find that the majority of guns stolen in the US come from the South.

  12. Development of hydrazinium nitroformate based solid propellants

    NARCIS (Netherlands)

    Schöyer, H.F.R.; Schnorhk, A.J.; Korting, P.A.O.G.; Lit, P.J. van; Mul, J.M.; Gadiot, G.; Meulenbrugge, J.J.

    1995-01-01

    The development of new high-performance propellant combinations requires the establishment of safety and handling characteristics and thermodynamic decomposition and explosive properties. This paper addresses the early development phases of a new composite solid propellant based on HNF as oxidizer

  13. RDX Detection with THz Spectroscopy

    Science.gov (United States)

    Michalopoulou, Zoi-Heleni; Mukherjee, Suman; Hor, Yew Li; Su, Ke; Liu, Zhiwei; Barat, Robert B.; Gary, Dale E.; Federici, John F.

    2010-10-01

    Spectroscopic analysis in the Terahertz frequency range, providing characteristic “signatures” for explosive and non-explosive materials, is proposed as an efficient and powerful tool for explosive identification. It is demonstrated that spectral responses of materials can be used as fingerprints that distinguish cyclotrimethylenetrinitramine (RDX) from other materials even with simple detectors and a limited number of available frequencies. Detection is performed using a modified least squares approach and multilayer perceptrons that operate on smoothed reflectance spectra. The performance of the detectors is evaluated through application to spectra of RDX and several common materials. A Receiver Operating Characteristic curve analysis demonstrates that our detectors exhibit the desirable properties of high probability of detection and low probability of false alarm.

  14. Modeling internal ballistics of gas combustion guns.

    Science.gov (United States)

    Schorge, Volker; Grossjohann, Rico; Schönekess, Holger C; Herbst, Jörg; Bockholdt, Britta; Ekkernkamp, Axel; Frank, Matthias

    2016-05-01

    Potato guns are popular homemade guns which work on the principle of gas combustion. They are usually constructed for recreational rather than criminal purposes. Yet some serious injuries and fatalities due to these guns are reported. As information on the internal ballistics of homemade gas combustion-powered guns is scarce, it is the aim of this work to provide an experimental model of the internal ballistics of these devices and to investigate their basic physical parameters. A gas combustion gun was constructed with a steel tube as the main component. Gas/air mixtures of acetylene, hydrogen, and ethylene were used as propellants for discharging a 46-mm caliber test projectile. Gas pressure in the combustion chamber was captured with a piezoelectric pressure sensor. Projectile velocity was measured with a ballistic speed measurement system. The maximum gas pressure, the maximum rate of pressure rise, the time parameters of the pressure curve, and the velocity and path of the projectile through the barrel as a function of time were determined according to the pressure-time curve. The maximum gas pressure was measured to be between 1.4 bar (ethylene) and 4.5 bar (acetylene). The highest maximum rate of pressure rise was determined for hydrogen at (dp/dt)max = 607 bar/s. The muzzle energy was calculated to be between 67 J (ethylene) and 204 J (acetylene). To conclude, this work provides basic information on the internal ballistics of homemade gas combustion guns. The risk of injury to the operator or bystanders is high, because accidental explosions of the gun due to the high-pressure rise during combustion of the gas/air mixture may occur.

  15. Mechanism of RDX-Induced Seizures in Rats

    Science.gov (United States)

    2009-09-01

    benchmark for RDX. d. The main acute effect of RDX after ingestion of high doses is the induction of seizures accompanied by excessive salivation ...most animals that seize demonstrate excessive salivation (Schneider et al., 1977; Burdette et al., 1988; Crouse et al., 2006). These clinical signs...Padilla et al., 1998). A 2% (wet wt./vol.) homogenate was made in 0.1 M Na phosphate buffer ( pH 8.0) + 1% Triton, using a 20 sec burst (on ice) of

  16. Computational Study of the Structure and Mechanical Properties of the Molecular Crystal RDX

    Science.gov (United States)

    2012-11-01

    basic equilibrium properties of and transitions to and from the α and γ polymorphs in crystalline RDX based on the SB potential (17). Atomic-level...elastic constants, polymorph transitions , cleavage properties, and energy barriers to slip. The energy barriers to slip are determined through the... RDX molecule containing three R2N-NO2 groups, where each R=CH2; and (c) HMX molecule containing four R2N-NO2 groups with R=CH2

  17. Repetitive, small-bore two-stage light gas gun

    International Nuclear Information System (INIS)

    Combs, S.K.; Foust, C.R.; Fehling, D.T.; Gouge, M.J.; Milora, S.L.

    1991-01-01

    A repetitive two-stage light gas gun for high-speed pellet injection has been developed at Oak Ridge National Laboratory. In general, applications of the two-stage light gas gun have been limited to only single shots, with a finite time (at least minutes) needed for recovery and preparation for the next shot. The new device overcomes problems associated with repetitive operation, including rapidly evacuating the propellant gases, reloading the gun breech with a new projectile, returning the piston to its initial position, and refilling the first- and second-stage gas volumes to the appropriate pressure levels. In addition, some components are subjected to and must survive severe operating conditions, which include rapid cycling to high pressures and temperatures (up to thousands of bars and thousands of kelvins) and significant mechanical shocks. Small plastic projectiles (4-mm nominal size) and helium gas have been used in the prototype device, which was equipped with a 1-m-long pump tube and a 1-m-long gun barrel, to demonstrate repetitive operation (up to 1 Hz) at relatively high pellet velocities (up to 3000 m/s). The equipment is described, and experimental results are presented. 124 refs., 6 figs., 5 tabs

  18. Study on Combustion Characteristics and Propelling Projectile Motion Process of Bulk-Loaded Liquid Propellant

    Science.gov (United States)

    Xue, Xiaochun; Yu, Yonggang; Mang, Shanshan

    2017-07-01

    Data are presented showing that the problem of gas-liquid interaction instability is an important subject in the combustion and the propellant projectile motion process of a bulk-loaded liquid propellant gun (BLPG). The instabilities themselves arise from the sources, including fluid motion, to form a combustion gas cavity called Taylor cavity, fluid turbulence and breakup caused by liquid motion relative to the combustion chamber walls, and liquid surface breakup arising from a velocity mismatch on the gas-liquid interface. Typically, small disturbances that arise early in the BLPG combustion interior ballistic cycle can become amplified in the absence of burn rate limiting characteristics. Herein, significant attention has been given to developing and emphasizing the need for better combustion repeatability in the BLPG. Based on this goal, the concept of using different geometries of the combustion chamber is introduced and the concept of using a stepped-wall structure on the combustion chamber itself as a useful means of exerting boundary control on the combustion evolution to thus restrain the combustion instability has been verified experimentally in this work. Moreover, based on this background, the numerical simulation is devoted to a special combustion issue under transient high-pressure and high-temperature conditions, namely, studying the combustion mechanism in a stepped-wall combustion chamber with full monopropellant on one end that is stationary and the other end can move at high speed. The numerical results also show that the burning surface of the liquid propellant can be defined geometrically and combustion is well behaved as ignition and combustion progressivity are in a suitable range during each stage in this combustion chamber with a stepped-wall structure.

  19. Blower Gun pellet injection system for W7-X

    Energy Technology Data Exchange (ETDEWEB)

    Dibon, M., E-mail: mathias.dibon@ipp.mpg.de [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Baldzuhn, J.; Beck, M. [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Cardella, A. [Lehrstuhl für Nukleartechnik, TU Munich, Boltzmannstr. 15, 85748 Garching (Germany); Köchl, F. [Atominstitut, TU Wien, 1020 Vienna (Austria); Kocsis, G. [Wigner RCP, RMI, P.O. Box 49, H-1525 Budapest-114 (Hungary); Lang, P.T. [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Macian-Juan, R. [Lehrstuhl für Nukleartechnik, TU Munich, Boltzmannstr. 15, 85748 Garching (Germany); Ploeckl, B. [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Szepesi, T. [Wigner RCP, RMI, P.O. Box 49, H-1525 Budapest-114 (Hungary); Weisbart, W. [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-10-15

    Highlights: • Operational principle of the ASDEX Upgrade Blower Gun. • Guiding tube properties for pellet guiding according to the requirements of W7-X. • Diagnostics for the characterization of the injection system. • Experimental procedure to investigate the performance of the Blower Gun. • Results concerning pellet speeds, mass loss, delivery efficiency and exit angle. - Abstract: Foreseen to perform pellet investigations in the new stellarator W7-X, the former ASDEX Upgrade Blower Gun was revised and revitalized. The systems operational characteristics have been surveyed in a test bed. The gun is designed to launch cylindrical pellets with 2 mm diameter and 2 mm length, produced from frozen deuterium D{sub 2}, hydrogen H{sub 2} or a gas mixture consisting of 50% H{sub 2} and 50% D{sub 2}. Pellets are accelerated by a short pulse of pressurized helium propellant gas to velocities in the range of 100–250 m/s. Delivery reliabilities at the launcher exit reach almost unity. The initial pellet mass is reduced to about 50% during the acceleration process. Pellet transfer to the plasma vessel was investigated by a first mock up guiding tube version. Transfer through this S-shaped stainless steel guiding tube (inner diameter 8 mm; length 6 m) containing two 1 m curvature radii was investigated for all pellet types. Tests were performed applying repetition rates from 2 Hz to 50 Hz and propellant gas pressures ranging from 0.1 to 0.6 MPa. For both H{sub 2} and D{sub 2}, low overall delivery efficiencies were observed at slow repetition rates, but stable efficiencies of about 90% above 10 Hz. About 10% of the mass is eroded while flying through the guiding tube. Pellets exit the guiding tube with an angular spread of less than 14°.

  20. Verification of RDX Photolysis Mechanism

    National Research Council Canada - National Science Library

    Peyton, Gary

    1999-01-01

    ... such as formaldehyde and formic acid, as well as the inorganic ions nitrate and nitrite. This implies that UV photolysis might provide a satisfactory and economical treatment system for RDX in water...

  1. Modeling Nonlinear Elastic-plastic Behavior of RDX Single Crystals During Indentation

    Science.gov (United States)

    2012-01-01

    single crystals has also been probed using shock experiments (6, 12) and molecular dynamics simulations (12–14). RDX undergoes a polymorphic phase...Patterson, J.; Dreger, Z.; Gupta, Y. Shock-wave Induced Phase Transition in RDX Single Crystals. J. Phys. Chem. B 2007, 111, 10897–10904. 17. Bedrov, D...and Volume Compression of β - HMX and RDX . In Proc. Int. Symp. High Dynamic Pressures; Commissariat a l’Energie Atomique: Paris, 1978; pp 3–8. 24

  2. Application of transient burning rate model of solid propellant in electrothermal-chemical launch simulation

    Directory of Open Access Journals (Sweden)

    Yan-jie Ni

    2016-04-01

    Full Text Available A 30 mm electrothermal-chemical (ETC gun experimental system is employed to research the burning rate characteristics of 4/7 high-nitrogen solid propellant. Enhanced gas generation rates (EGGR of propellants during and after electrical discharges are verified in the experiments. A modified 0D internal ballistic model is established to simulate the ETC launch. According to the measured pressure and electrical parameters, a transient burning rate law including the influence of EGGR coefficient by electric power and pressure gradient (dp/dt is added into the model. The EGGR coefficient of 4/7 high-nitrogen solid propellant is equal to 0.005 MW−1. Both simulated breech pressure and projectile muzzle velocity accord with the experimental results well. Compared with Woodley's modified burning rate law, the breech pressure curves acquired by the transient burning rate law are more consistent with test results. Based on the parameters calculated in the model, the relationship among propellant burning rate, pressure gradient (dp/dt and electric power is analyzed. Depending on the transient burning rate law and experimental data, the burning of solid propellant under the condition of plasma is described more accurately.

  3. Fenomen erozije cevi naoružanja / Gun barrel erosion

    Directory of Open Access Journals (Sweden)

    Slobodan Ilić

    2009-07-01

    Full Text Available U radu su prikazana dosadašnja istraživanja erozije cevi. Trošenje cevi je neizbežan proces do kojeg dolazi pri svakom opaljenju. Erozija cevi može se definisati kao progresivna povreda ili oštećenje površine cevi i proširenje kalibra usled opaljenja, koja utiče na: gubitak ili pad početne brzine projektila, tačnost i efektivnost oruđa. Kao glavni uzročnici koji utiču na intenzitet erozije cevi opisani su termički, hemijski i mehanički faktori. Njihov uticaj prikazan je u interakciji cev-projektil-barutno punjenje. / An overview of research into gun barrel erosion is presented in this paper. The gun bore wear is an unavoidable process during normal firing. The wear can be defined as progressive damage of the bore surface and enlargement of the bore, ultimately resulting in loss in the muzzle velocity, range and accuracy. Thermal, chemical and mechanical factors are described as major factors of gun barrel erosion. The influence of these factors is presented in the interaction of gun tube - projectile - propellant.

  4. School-Based and Community-Based Gun Safety Educational Strategies for Injury Prevention.

    Science.gov (United States)

    Holly, Cheryl; Porter, Sallie; Kamienski, Mary; Lim, Aubrianne

    2018-05-01

    Nearly 1,300 children in the United States die because of firearm-related injury each year and another 5,790 survive gunshot wounds, making the prevention of firearm-related unintentional injury to children of vital importance to families, health professionals, and policy makers. To systematically review the evidence on school-based and community-based gun safety programs for children aged 3 to 18 years. Systematic review. Twelve databases were searched from their earliest records to December 2016. Interventional and analytic studies were sought, including randomized controlled trials, quasi-experimental studies, as well as before-and-after studies or cohort studies with or without a control that involved an intervention. The low level of evidence, heterogeneity of studies, and lack of consistent outcome measures precluded a pooled estimate of results. A best evidence synthesis was performed. Results support the premise that programs using either knowledge-based or active learning strategies or a combination of these may be insufficient for teaching gun safety skills to children. Gun safety programs do not improve the likelihood that children will not handle firearms in an unsupervised situation. Stronger research designs with larger samples are needed to determine the most effective way to transfer the use of the gun safety skills outside the training session and enable stronger conclusions to be drawn.

  5. A Study of Interaction of Laser Light with Small Drops of XM46 Propellant and Related Liquids

    National Research Council Canada - National Science Library

    Juvan, Kim

    1999-01-01

    Stimulated Raman spectroscopy (SRS) has been explored as a possible diagnostic tool to determine if observable changes in composition occur in the liquid gun propellants containing hydroxyl ammonium nitrate (HAN...

  6. State Gun Law Environment and Youth Gun Carrying in the United States.

    Science.gov (United States)

    Xuan, Ziming; Hemenway, David

    2015-11-01

    Gun violence and injuries pose a substantial threat to children and youth in the United States. Existing evidence points to the need for interventions and policies for keeping guns out of the hands of children and youth. (1) To examine the association between state gun law environment and youth gun carrying in the United States, and (2) to determine whether adult gun ownership mediates this association. This was a repeated cross-sectional observational study design with 3 years of data on youth gun carrying from US states. The Youth Risk Behavior Survey comprises data of representative samples of students in grades 9 to 12 from biennial years of 2007, 2009, and 2011. We hypothesized that states with more restrictive gun laws have lower rates of youth gun carrying, and this association is mediated by adult gun ownership. State gun law environment as measured by state gun law score. Youth gun carrying was defined as having carried a gun on at least 1 day during the 30 days before the survey. In the fully adjusted model, a 10-point increase in the state gun law score, which represented a more restrictive gun law environment, was associated with a 9% decrease in the odds of youth gun carrying (adjusted odds ratio [AOR], 0.91 [95% CI, 0.86-0.96]). Adult gun ownership mediated the association between state gun law score and youth gun carrying (AOR, 0.94 [ 95% CI, 0.86-1.01], with 29% attenuation of the regression coefficient from -0.09 to -0.07 based on bootstrap resampling). More restrictive overall gun control policies are associated with a reduced likelihood of youth gun carrying. These findings are relevant to gun policy debates about the critical importance of strengthening overall gun law environment to prevent youth gun carrying.

  7. Bioremediation of RDX in the vadose zone beneath the Pantex Plant

    Energy Technology Data Exchange (ETDEWEB)

    Shull, T.L.; Speitel, G.E. Jr.; McKinney, D.C. [Univ. of Texas, Austin, TX (United States). Dept. of Civil Engineering

    1999-01-01

    The presence of dissolved high explosives (HE), in particular RDX and HMX, is well documented in the perched aquifer beneath the Pantex Plant, but the distribution of HE in the vadose zone has not yet been well defined. Although current remediation activities focus on the contamination in the perched aquifer, eventually regulatory concern is likely to turn to the residual contamination in the vadose zone. Sources of HE include the infiltration of past wastewater discharges from several HE-processing facilities through the ditch drainage system and leachate from former Landfill 3. With limited existing data on the HE distribution in the vadose zone and without preventive action, it must be assumed that residual HE could be leached into infiltrating water, providing a continuing supply of contamination to the perched aquifer. The purpose of this project was to more closely examine the fate and transport of HE in the vadose zone through mathematical modeling and laboratory experimentation. In particular, this report focuses on biodegradation as one possible fate of HE. Biodegradation of RDX in the vadose zone was studied because it is both present in highest concentration and is likely to be of the greatest regulatory concern. This study had several objectives: determine if indigenous soil organisms are capable of RDX biodegradation; determine the impact of electron acceptor availability and nutrient addition on RDX biodegradation; determine the extent of RDX mineralization (i.e., conversion to inorganic carbon) during biodegradation; and estimate the kinetics of RDX biodegradation to provide information for mathematical modeling of fate and transport.

  8. One-Dimensional Analysis of a Liquid Jet in a Regenerative Liquid Propellant Gun

    Science.gov (United States)

    1990-04-01

    1.400 MOLECULAR WEIGHT(GM/GMOL) 28.960 PROPERTIES OF PROJECTILE 42 MASS(GM) 97.300 LOCATION OF BASE WITH RESPECT TO TUBE ENTRANCE(CM) 0.000 TRAVEL...MPA) 1206.500 DERIVATIVE OF MODULUS W.R.T PRESSURE(-) 2.500 CHEMICAL ENERGY(J/GM) 3240.807 RATIO OF SPECIFIC HEATS OF PRODUCTS(-) 1.267 MOLECULAR ...0.147100 EMISIVITY FACTOR (-) 1.00000 HEAT LOSS MULTIPLIER FACTOR (-) 1.00000 TOTAL PROPELLANT WEIGHT (GM) 117.2470 TOTAL CHEMICAL ENERGY (KJ) 379.9750

  9. Gun ownership and social gun culture.

    Science.gov (United States)

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-06-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Water gun vs air gun: A comparison

    Science.gov (United States)

    Hutchinson, D.R.; Detrick, R. S.

    1984-01-01

    The water gun is a relatively new marine seismic sound source that produces an acoustic signal by an implosive rather than explosive mechanism. A comparison of the source characteristics of two different-sized water guns with those of conventional air guns shows the the water gun signature is cleaner and much shorter than that of a comparable-sized air gun: about 60-100 milliseconds (ms) for an 80-in3. (1.31-liter (I)) water gun compared with several hundred ms for an 80-in3. (1.31-1) air gun. The source spectra of water guns are richer in high frequencies (>200 Hz) than are those of air guns, but they also have less energy than those of air guns at low frequencies. A comparison between water gun and air gun reflection profiles in both shallow (Long Island Sound)-and deep (western Bermuda Rise)-water settings suggests that the water gun offers a good compromise between very high resolution, limited penetration systems (e.g. 3.5-kHz profilers and sparkers) and the large volume air guns and tuned air gun arrays generally used where significant penetration is required. ?? 1984 D. Reidel Publishing Company.

  11. New Approaches to Evaluate the Biological Degradation of RDX in Groundwater

    Science.gov (United States)

    2014-08-27

    again indicate the diversity of active microorganisms associated with RDX biodegradation in the environmental samples. When cheese whey was absent...34  2.2 Task 2 – Geochemical and Environmental Conditions Affecting RDX Biodegradation ............ 36  2.2.1 Objective...Degrading Microorganisms . 49  2.3.1 Objective

  12. Gas powered fluid gun with recoil mitigation

    Science.gov (United States)

    Grubelich, Mark C; Yonas, Gerold

    2013-11-12

    A gas powered fluid gun for propelling a stream or slug of a fluid at high velocity toward a target. Recoil mitigation is provided that reduces or eliminates the associated recoil forces, with minimal or no backwash. By launching a quantity of water in the opposite direction, net momentum forces are reduced or eliminated. Examples of recoil mitigation devices include a cone for making a conical fluid sheet, a device forming multiple impinging streams of fluid, a cavitating venturi, one or more spinning vanes, or an annular tangential entry/exit.

  13. Research on the combustion properties of propellants with low content of nano metal powders

    Energy Technology Data Exchange (ETDEWEB)

    Zhi, Jiang; Shu-Fen, Li [Department of Chemical Physics, University of Science and Technology of China, Hefei 230026 (China); Feng-Qi, Zhao; Zi-Ru, Liu; Cui-Mei, Yin; Yang, Luo; Shang-Wen, Li [Xi' an Modern Chemistry Research Inst., Xi' an 710065 (China)

    2006-04-15

    A comparison of various experimental results for combustionrelated properties evaluation, including burning rates, deflagration heat, flame structures and thermal decomposition properties, of AP/RDX/Al/HTPB composite propellants containing nano metal powders is presented. The thermal behavior of n-Al (nano grain size aluminum) and g-Al (general grain size aluminum i.e., 10 {mu}m) heated in air was also investigated by thermogravimetry. The burning rates results indicate that the usage of bimodal aluminum distribution with the ratio around 4: 1 of n-Al to g-Al or the addition of 2% nano nickel powders (n-Ni) will improve the burning behavior of the propellant, while the usage of grading aluminum powders with the ratio 1: 1 of n-Al to g-Al will impair the combustion of the propellant. Results show that n-Al and n-Ni both have a lower heating capacity, lower ignition threshold and shorter combustion time than g-Al. In addition n-Al is inclined to burn in single particle form. And the thermal analysis results show that n-Ni can catalyze the thermal decomposition of AP in the propellant. The results also confirm the high reactivity of n-Al, which will lead to a lower reaction temperature and rather higher degree of reaction ratio as compared with g-Al in air. All these factors will influence the combustion of propellants. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

  14. Biodegradation of RDX within soil-water slurries using a combination of differing redox incubation conditions

    International Nuclear Information System (INIS)

    Waisner, S.; Hansen, L.; Fredrickson, H.; Nestler, C.; Zappi, M.; Banerji, S.; Bajpai, R.

    2002-01-01

    Biodegradation of 14 C-tagged hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was studied in aerobic, anaerobic, and anaerobic/aerobic slurries to identify the conditions maximizing RDX-mineralization in Cornhusker Army Ammunition Plant (CAAP, NE) groundwater. Supplementation with phosphate and adequate quantities of acetate caused 25% mineralization of RDX in 3 weeks by microorganisms native to CAAP. Under anaerobic conditions, the same supplementation resulted in 20% mineralization in 3 weeks and 30% mineralization in 6 weeks. The highest degree of mineralization (50%) was obtained under aerobic conditions when the contaminated groundwater was augmented with a consortium of three microbes isolated from another RDX contaminated soil (Hastings, NE) in addition to supplemented with phosphate and acetic acid. Use of complex organic sources (potato or corn starch) slowed down the rates of mineralization under anaerobic conditions, but rapid mineralization ensued as soon as the aerobic conditions were created. Final RDX concentrations in aqueous phase were below detection limit under most conditions. Assimilation of RDX by the cells was negligible

  15. Reconstruction of pressure sores with perforator-based propeller flaps.

    Science.gov (United States)

    Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G

    2011-03-01

    Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.

  16. Theoretical studies on the thermodynamic properties and detonation properties of cyclotrimethylene trinitramine (RDX with aluminum and boron metals.

    Directory of Open Access Journals (Sweden)

    Nilgün Şen

    2016-10-01

    Full Text Available The B3LYP/6-311++G(2df,2p density functional theory (DFT method was used to investigate molecular geometry and thermodynamic properties of RDX and RDX derivatives containing Al and B metals. The detonation velocity (D and detonation pressure (P, estimated by using Kamlet–Jacobs and in literature equations, respectively. Total energies (Et, frontier orbital energy (EHOMO, ELOMO, energy gap (ΔELUMO–HOMO and theoretical molecular density (ρ were calculated with Spartan 14 software package program. It was shown that the presence of aluminum and boron atoms affects the good thermal stabilities. The results show that the composite RDX-Al, RDX-B derivatives have higher detonation performance and higher density than RDX. RDX-Al derivatives appeared to be superior to RDX-B mixtures in terms of these parameters. These results provide information on the moleculer design of new energetic materials.

  17. On Intelligent Design and Planning Method of Process Route Based on Gun Breech Machining Process

    Science.gov (United States)

    Hongzhi, Zhao; Jian, Zhang

    2018-03-01

    The paper states an approach of intelligent design and planning of process route based on gun breech machining process, against several problems, such as complex machining process of gun breech, tedious route design and long period of its traditional unmanageable process route. Based on gun breech machining process, intelligent design and planning system of process route are developed by virtue of DEST and VC++. The system includes two functional modules--process route intelligent design and its planning. The process route intelligent design module, through the analysis of gun breech machining process, summarizes breech process knowledge so as to complete the design of knowledge base and inference engine. And then gun breech process route intelligently output. On the basis of intelligent route design module, the final process route is made, edited and managed in the process route planning module.

  18. Understanding metastable phase transformation during crystallization of RDX, HMX and CL-20: experimental and DFT studies.

    Science.gov (United States)

    Ghosh, Mrinal; Banerjee, Shaibal; Shafeeuulla Khan, Md Abdul; Sikder, Nirmala; Sikder, Arun Kanti

    2016-09-14

    Multiphase growth during crystallization severely affects deliverable output of explosive materials. Appearance and incomplete transformation of metastable phases are a major source of polymorphic impurities. This article presents a methodical and molecular level understanding of the metastable phase transformation mechanism during crystallization of cyclic nitramine explosives, viz. RDX, HMX and CL-20. Instantaneous reverse precipitation yielded metastable γ-HMX and β-CL-20 which undergo solution mediated transformation to the respective thermodynamic forms, β-HMX and ε-CL-20, following 'Ostwald's rule of stages'. However, no metastable phase, anticipated as β-RDX, was evidenced during precipitation of RDX, which rather directly yielded the thermodynamically stable α-phase. The γ→β-HMX and β→ε-CL-20 transformations took 20 and 60 minutes respectively, whereas formation of α-RDX was instantaneous. Density functional calculations were employed to identify the possible transition state conformations and to obtain activation barriers for transformations at wB97XD/6-311++G(d,p)(IEFPCM)//B3LYP/6-311G(d,p) level of theory. The computed activation barriers and lattice energies responsible for transformation of RDX, HMX and CL-20 metastable phases to thermodynamic ones conspicuously supported the experimentally observed order of phase stability. This precise result facilitated an understanding of the occurrence of a relatively more sensitive and less dense β-CL-20 phase in TNT based melt-cast explosive compositions, a persistent and critical problem unanswered in the literature. The crystalline material recovered from such compositions revealed a mixture of β- and ε-CL-20. However, similar compositions of RDX and HMX never showed any metastable phase. The relatively long stability with the highest activation barrier is believed to restrict complete β→ε-CL-20 transformation during processing. Therefore a method is suggested to overcome this issue.

  19. Electron guns for accelerators

    International Nuclear Information System (INIS)

    Rangarajan, L.M.; Mahadevan, S.; Ramamurthi, S.S.

    1995-01-01

    The high voltage, high current electron guns developed elsewhere for Linacs are based on cathode pulsing with direct emitting cathodes. Our grid pulsed triode gun employs indirect emitting cathode pellet under electron bombardment or a direct cathode emitter. Electron beam from the gun is injected to the accelerator guide at 40 kV and pulse duration is 2.8μsec. The gun is limited to axially symmetric geometry and electron optical design is optimized by computer programming. The gun with a water cooled Faraday cup is connected to a vacuum system comprising of a sputter ion pump and sorption pump. Working pressure is 1x10 -6 Pa. Gun is designed to be baked as an assembly at temperatures of 400 degC while vacuum processing. Materials are therefore restricted to refractory metals, SS, OFHC copper and all the electrodes are housed inside a ceramic tube. Lower Z graphite is used as a base material of Faraday cup. Grid is non-intercepting modulator anode, a new feature introduced, as compared to meshed grid system by others. CAT gun delivers 160 mA current pulses at 40 kV and its working characteristics such as perveance, emittance and beam radius compare well with SLAC and Hermosa guns. The above guns can be used for electron beam machines such as medical Linacs, industrial accelerators and EB welding equipment. (author). 2 refs., 2 figs

  20. Numerically-based ducted propeller design using vortex lattice lifting line theory

    OpenAIRE

    Stubblefield, John M.

    2008-01-01

    CIVINS (Civilian Institutions) Thesis document This thesis used vortex lattice lifting line theory to model an axisymmetrical-ducted propeller with no gap between the duct and the propeller. The theory required to model the duct and its interaction with the propeller were discussed and implemented in Open-source Propeller Design and Analysis Program (OpenProp). Two routines for determining the optimum circulation distribution were considered, and a method based on calculus of variation...

  1. Calculation for Primary Combustion Characteristics of Boron-Based Fuel-Rich Propellant Based on BP Neural Network

    OpenAIRE

    Wan'e, Wu; Zuoming, Zhu

    2012-01-01

    A practical scheme for selecting characterization parameters of boron-based fuel-rich propellant formulation was put forward; a calculation model for primary combustion characteristics of boron-based fuel-rich propellant based on backpropagation neural network was established, validated, and then was used to predict primary combustion characteristics of boron-based fuel-rich propellant. The results show that the calculation error of burning rate is less than ± 7 . 3 %; in the formulation rang...

  2. Gun Control, Gun Ownership, and Suicide Prevention.

    Science.gov (United States)

    Lester, David

    1988-01-01

    Explored relationship between the extent of gun ownership and the strictness of gun control laws to suicide and homicide rates in the nine major geographic regions of the United States. Found gun ownership, rather than the strictness of gun control laws, was the strongest correlate of the rates of suicide and homicide by guns. (Author)

  3. Field evaluation of a self-propelled sprayer and effects of the application rate on spray deposition and losses to the ground in greenhouse tomato crops.

    Science.gov (United States)

    Sánchez-Hermosilla, Julián; Rincón, Víctor J; Páez, Francisco; Agüera, Francisco; Carvajal, Fernando

    2011-08-01

    In the greenhouses of south-eastern Spain, plant protection products are applied using mainly sprayers at high pressures and high volumes. This results in major losses on the ground and less than uniform spray deposition on the canopy. Recently, self-propelled vehicles equipped with vertical spray booms have appeared on the market. In this study, deposition on the canopy and the losses to the ground at different spray volumes have been compared, using a self-propelled vehicle with vertical spray booms versus a gun sprayer. Three different spray volumes have been tested with a boom sprayer, and two with a spray gun. The vehicle with the vertical spray boom gave similar depositions to those made with the gun, but at lower application volumes. Also, the distribution of the vertical spray boom was more uniform, with lower losses to the ground. The vertical spray booms used in tomato crops improve the application of plant protection products with respect to the spray gun, reducing the application volumes and the environmental risks of soil pollution. Copyright © 2011 Society of Chemical Industry.

  4. In-Bore Liquid Injection for Barrel Cooling: Comparison of Liquid and Solid Additives Using Constant Breach Pressure Ideal Gun Calculations

    National Research Council Canada - National Science Library

    Kotlar, Anthony

    1999-01-01

    .... These calculations give limiting values for projectile muzzle kinetic energy (KE), assuming complete mixing of the liquid additive and the solid propellant This is a worst-case scenario for the new concept to reduce gun barrel heating...

  5. Shock therapy: Gris Gun's shock absorber can take the punch

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2000-04-01

    A newly developed shock impedance tool that isolates downhole tools that measure the effects of well stimulation techniques from being damaged by the violent shaking caused by various well stimulation techniques which combine perforating and propellant technology in a single tool, is discussed. The shock exerted by a perforating gun can exceed 25,000 G forces within 100 to 300 milliseconds, may damage or even destroy the sensitive electronics housed in the various recorders that record data about fracture gradients, permeability and temperature. The shock absorber developed by Tesco Gris Gun and Computalog, incorporates the mechanics of a piston style shock absorber in combination with a progressive spring stack and energy-dampening silicone oil chambers. The end results is an EUE 'slim line' assembly that is adaptable between the gun perforating string and the electronic equipment. It is typically attached below, reducing the shock load by as much as 90 per cent. The shock absorber is now available commercially through Gris Gun's exclusive distributorship. An improved version, currently under development, will be used for wireline perforating and tubing-conveyed perforating applications. 2 figs.

  6. Gun muzzle flash detection using a CMOS single photon avalanche diode

    Science.gov (United States)

    Merhav, Tomer; Savuskan, Vitali; Nemirovsky, Yael

    2013-10-01

    Si based sensors, in particular CMOS Image sensors, have revolutionized low cost imaging systems but to date have hardly been considered as possible candidates for gun muzzle flash detection, due to performance limitations, and low SNR in the visible spectrum. In this study, a CMOS Single Photon Avalanche Diode (SPAD) module is used to record and sample muzzle flash events in the visible spectrum, from representative weapons, common on the modern battlefield. SPADs possess two crucial properties for muzzle flash imaging - Namely, very high photon detection sensitivity, coupled with a unique ability to convert the optical signal to a digital signal at the source pixel, thus practically eliminating readout noise. This enables high sampling frequencies in the kilohertz range without SNR degradation, in contrast to regular CMOS image sensors. To date, the SPAD has not been utilized for flash detection in an uncontrolled environment, such as gun muzzle flash detection. Gun propellant manufacturers use alkali salts to suppress secondary flashes ignited during the muzzle flash event. Common alkali salts are compounds based on Potassium or Sodium, with spectral emission lines around 769nm and 589nm, respectively. A narrow band filter around the Potassium emission doublet is used in this study to favor the muzzle flash signal over solar radiation. This research will demonstrate the SPAD's ability to accurately sample and reconstruct the temporal behavior of the muzzle flash in the visible wavelength under the specified imaging conditions. The reconstructed signal is clearly distinguishable from background clutter, through exploitation of flash temporal characteristics.

  7. Preventing gun injuries in children.

    Science.gov (United States)

    Crossen, Eric J; Lewis, Brenna; Hoffman, Benjamin D

    2015-02-01

    Firearms are involved in the injury and death of a large number of children each year from both intentional and unintentional causes. Gun ownership in homes with children is common, and pediatricians should incorporate evidence-based means to discuss firearms and protect children from gun-related injuries and violence. Safe storage of guns, including unloaded guns locked and stored separately from ammunition, can decrease risks to children, and effective tools are available that pediatricians can use in clinical settings to help decrease children's access to firearms. Furthermore, several community-based interventions led by pediatricians have effectively reduced firearm-related injury risks to children. Educational programs that focus on children's behavior around guns have not proven effective. © American Academy of Pediatrics, 2015. All rights reserved.

  8. Rocket Solid Propellant Alternative Based on Ammonium Dinitramide

    Directory of Open Access Journals (Sweden)

    Grigore CICAN

    2017-03-01

    Full Text Available Due to the continuous run for a green environment the current article proposes a new type of solid propellant based on the fairly new synthesized oxidizer, ammonium dinitramide (ADN. Apart of having a higher specific impulse than the worldwide renowned oxidizer, ammonium perchlorate, ADN has the advantage, of leaving behind only nitrogen, oxygen and water after decomposing at high temperatures and therefore totally avoiding the formation of hydrogen chloride fumes. Based on the oxidizer to fuel ratios of the current formulations of the major rocket solid booster (e.g. Space Shuttle’s SRB, Ariane 5’s SRB which comprises mass variations of ammonium perchlorate oxidizer (70-75%, atomized aluminum powder (10-18% and polybutadiene binder (12-20% a new solid propellant was formulated. As previously stated, the new propellant formula and its variations use ADN as oxidizer and erythritol tetranitrate as fuel, keeping the same polybutadiene as binder.

  9. Current state of the art of HNF based composite propellants

    NARCIS (Netherlands)

    Ciucci, A.; Frota, O.; Welland, W.H.M.; Heijden, A.E.D.M. van der; Leeming, B.; Bellerby, J.M.; Brotzu, A.

    2004-01-01

    The main activities currently performed for the development of HNF-based propellants are presented. The objectives and approach adopted are described. The results obtained on the HNF decomposition mechanism and on the re- and co-crystallisation of HNF with potential propellant ingredients are

  10. Gun Theft and Crime.

    Science.gov (United States)

    Cook, Philip J

    2018-06-01

    Some law enforcement officials and other observers have asserted that theft is the primary source of guns to crime. In fact, the role of theft in supplying the guns used in robbery, assault, and murder is unknown, and current evidence provides little guidance about whether an effective program to reduce gun theft would reduce gun violence. The current article analyzes publicly available national data on gun theft together with a unique data set for Chicago. The results tend to support a conclusion that stolen guns play only a minor role in crime. First, publicly available data are used to calculate that thefts are only about 1% of all gun transactions nationwide. Second, an analysis of original data from Chicago demonstrates that less than 3% of crime guns recovered by the police have been reported stolen to the Chicago Police Department (CPD). If a gun is reported stolen, there is a 20% chance that it will be recovered, usually in conjunction with an arrest for illegal carrying. Less than half of those picked up with a stolen gun have a criminal record that includes violent offenses. Third, results from surveys of convicted criminals, both nationally and in Chicago, suggest that it is rare for respondents to have stolen the gun used in their most recent crime. The data on which these results are based have various shortcomings. A research agenda is proposed that would provide more certainty about the role of theft.

  11. Image based measurement techniques for aircraft propeller flow diagnostics : Propeller slipstream investigations at high-lift conditions and thrust reverse

    NARCIS (Netherlands)

    Roosenboom, E.W.M.

    2011-01-01

    The aim of the thesis is to measure the propeller slipstream properties (velocity and vorticity) and to assess the unsteady and instantaneous behavior of the propeller flow field at high disk loadings, zero thrust and thrust reverse using the image based measurement techniques. Along with its

  12. Effects of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in zebrafish: General and reproductive toxicity

    Science.gov (United States)

    Mukhi, S.; Patino, R.

    2008-01-01

    Mixed-sex populations of young adult zebrafish (???2-month-old) were exposed to measured RDX concentrations of 0, 1 or 9.6 ppm for up to 12 weeks followed by a 15-day rearing period in untreated water. RDX caused high mortality at 9.6 ppm, with most deaths occurring within the first 8 weeks of exposure. RDX at 9.6 ppm caused lower body weights at 4 and 8 weeks of exposure; and at 1 ppm, lower body weight was observed only at 4 weeks. Fish length was not affected by treatment at any time during the exposure period. The bioconcentration factor for RDX seemed to be influenced by time of exposure but not by water RDX concentration; its overall values were 1.01 ?? 0.13, 0.91 ?? 0.06 and 2.23 ?? 0.04 at 4, 8 weeks and 12 weeks, respectively. RDX was not detected in fish collected after the 15-day recovery period. In a separate experiment, adult females and males were separately exposed to RDX at measured concentrations of 0, 0.5 and 3.2 ppm for a period of 6 weeks. Reproductive performance was evaluated by biweekly breeding of the fish and measuring packed-egg volume (PEV) as index of fecundity. At 0.5 ppm, RDX caused elevated PEV levels relative to the control value at 2 weeks but not at 4 or 6 weeks, whereas no significant effects were noted at 3.2 ppm. Egg fertilization and embryo hatching rates were not affected by RDX at any of the concentrations tested. In conclusion, RDX at sublethal concentrations causes short-term negative effects on growth and, at 0.5 ppm, positive effects on fecundity. ?? 2008 Elsevier Ltd.

  13. Lake Wobegon’s Guns: Overestimating Our Gun-Related Competences

    Directory of Open Access Journals (Sweden)

    Emily Stark

    2016-02-01

    Full Text Available The Lake Wobegon Effect is a general tendency for people to overestimate their own abilities. In this study, the authors conducted a large, nationally-representative survey of U.S. citizens to test whether Americans overestimate their own gun-relevant personality traits, gun safety knowledge, and ability to use a gun in an emergency. The authors also tested how gun control attitudes, political identification, gender, and gun experience affect self-perceptions. Consistent with prior research on the Lake Wobegon Effect, participants overestimated their gun-related competencies. Conservatives, males, and pro-gun advocates self-enhanced somewhat more than their counterparts but this effect was primarily due to increased gun experience among these participants. These findings are important to policymakers in the area of gun use, because overconfidence in one’s gun-related abilities may lead to a reduced perceived need for gun training.

  14. Burning characteristics of ammonium nitrate-based composite propellants supplemented with ammonium dichromate

    Energy Technology Data Exchange (ETDEWEB)

    Kohga, Makoto; Nishino, Saeko [Department of Applied Chemistry, National Defense Academy, Yokosuka, Kanagawa 239-8686 (Japan)

    2009-08-15

    Ammonium nitrate (AN)-based composite propellants have attracted much attention, primarily because of the clean burning nature of AN as an oxidizer. However, such propellants have some disadvantages such as poor ignition and low burning rate. Ammonium dichromate (ADC) is used as a burning catalyst for AN-based propellants; however, the effect of ADC on the burning characteristics has yet to be sufficiently delineated. The burning characteristics of AN/ADC propellants prepared with various contents of AN and ADC have been investigated in this study. The theoretical performance of an AN-based propellant is improved by the addition of ADC. The increase in the burning rate is enhanced and the pressure deflagration limit (PDL) becomes lower with increasing amount of ADC added. The increasing ratio of the burning rate with respect to the amount of ADC is independent of the AN content and the combustion pressure. The optimal amount of ADC for improving the burning characteristics has been determined. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  15. HIGH VELOCITY THERMAL GUN FOR SURFACE PREPARATION AND TREATMENT

    Directory of Open Access Journals (Sweden)

    I.A. Gorlach

    2012-01-01

    Full Text Available Many surface preparation and treatment processes utilise compressed air to propel particles against surfaces in order to clean and treat them. The effectiveness of the processes depends on the velocity of the particles, which in turn depends on the pressure of the compressed air. This paper describes a thermal gun built on the principles of High Velocity Air Fuel (HVAF and High Velocity Oxy Fuel (HVOF processes. The designed apparatus can be used for abrasive blasting, coating of surfaces, cutting of rocks, removing rubber from mining equipment, cleaning of contaminations etc.

  16. Aluminum agglomeration involving the second mergence of agglomerates on the solid propellants burning surface: Experiments and modeling

    Science.gov (United States)

    Ao, Wen; Liu, Xin; Rezaiguia, Hichem; Liu, Huan; Wang, Zhixin; Liu, Peijin

    2017-07-01

    The agglomeration of aluminum particles usually occurs on the burning surface of aluminized composite propellants. It leads to low propellant combustion efficiency and high two-phase flow losses. To reach a thorough understanding of aluminum agglomeration behaviors, agglomeration processes, and particles size distribution of Al/AP/RDX/GAP propellants were studied by using a cinephotomicrography experimental technique, under 5 MPa. Accumulation, aggregation, and agglomeration phenomena of aluminum particles have been inspected, as well as the flame asymmetry of burning agglomerates. Results reveals that the dependency of the mean and the maximum agglomeration diameter to the burning rate and the virgin aluminum size have the same trend. A second-time mergence of multiple agglomerates on the burning surface is unveiled. Two typical modes of second mergence are concluded, based upon vertical and level movement of agglomerates, respectively. The latter mode is found to be dominant and sometimes a combination of the two modes may occur. A new model of aluminum agglomeration on the burning surface of composite propellants is derived to predict the particulates size distribution with a low computational amount. The basic idea is inspired from the well-known pocket models. The pocket size of the region formed by adjacent AP particles is obtained through scanning electron microscopy of the propellant cross-section coupled to an image processing method. The second mergence mechanism, as well as the effect of the burning rate on the agglomeration processes, are included in the present model. The mergence of two agglomerates is prescribed to occur only if their separation distance is less than a critical value. The agglomerates size distribution resulting from this original model match reasonably with the experimental data. Moreover, the present model gives superior results for mean agglomeration diameter compared to common empirical and pocket models. The average prediction

  17. Gun Play

    Science.gov (United States)

    Mechling, Jay

    2008-01-01

    Biology and the particular gun culture of the United States come together to explain the persistent and powerful attraction of American boys to both real guns and toy guns. The 1990s saw adults begin to conflate "the gun problem" with "the boy problem," sparking attempts (largely failed) to banish toy guns from homes and…

  18. Feasibility of In Situ Redox Manipulation of Subsurface Sediments for RDX Remediation at Pantex

    Energy Technology Data Exchange (ETDEWEB)

    Szecsody, James E.; Fruchter, Jonathan S.; Mckinley, Mark A.; Resch, Charles T.; Gilmore, Tyler J.

    2001-12-31

    This laboratory study was conducted to assess RDX (hexahydro-1,3,5-trinitro-1,3,5 triazine) abiotic degradation by chemically reduced sediments and other geochemical aspects of the application of this technology to remediation of RDX contamination in groundwater at the U.S. DOE Pantex facility...

  19. Numerical Evaluation of a Light-Gas Gun Facility for Impact Test

    Directory of Open Access Journals (Sweden)

    C. Rahner

    2014-01-01

    Full Text Available Experimental tests which match the application conditions might be used to properly evaluate materials for specific applications. High velocity impacts can be simulated using light-gas gun facilities, which come in different types and complexities. In this work different setups for a one-stage light-gas gun facility have been numerically analyzed in order to evaluate their suitability for testing materials and composites used as armor protection. A maximal barrel length of 6 m and a maximal reservoir pressure of a standard industrial gas bottle (20 MPa were chosen as limitations. The numerical predictions show that it is not possible to accelerate the projectile directly to the desired velocity with nitrogen, helium, or hydrogen as propellant gas. When using a sabot corresponding to a higher bore diameter, the necessary velocity is achievable with helium and hydrogen gases.

  20. In-Depth Chemistry in Plasma-Exposed M30 and JA2 Gun Propellants

    National Research Council Canada - National Science Library

    Pesce-Rodriguez, Rose

    2001-01-01

    ...) method to detect low levels of NO in the propellant. It appears that for M30, profiles for radiation-induced denitration of nitrate esters are consistent with Beer's law, and that effects occur as deep...

  1. The influence of the choice of propeller design tool on propeller performance

    OpenAIRE

    Skåland, Edvard Knutsen

    2016-01-01

    In this master thesis different propeller design and analysis methods are presented and compared in terms of the accuracy and computational efficiency of their theory. These methods include lifting line, vortex lattice lifting surface and panel methods. A propeller design program based on lifting line theory was developed by the author. This program has been used together with the propeller design programs OpenProp and AKPD to make six propeller designs. The designs are based o...

  2. Enhanced propellant performance via environmentally friendly curable surface coating

    Directory of Open Access Journals (Sweden)

    Thelma Manning

    2017-06-01

    Full Text Available Surface coating of granular propellants is widely used in a multiplicity of propellants for small, medium and large caliber ammunition. All small caliber ball propellants exhibit burning progressivity due to application of effective deterrent coatings. Large perforated propellant grains have also begun utilizing plasticizing and impregnated deterrent coatings with the purpose of increasing charge weights for greater energy and velocity for the projectile. The deterrent coating and impregnation process utilizes volatile organic compounds (VOCs and hazardous air pollutants (HAPs which results in propellants that need to be forced air dried which impacts air quality. Propellants undergo temperature fluctuations during their life. Diffusion coefficients vary exponentially with variations in temperature. A small temperature increase can induce a faster migration, even over a short period of time, which can lead to large deviations in the concentration. This large concentration change in the ammunition becomes a safety or performance liability. The presence of both polymeric deterrents and nitroglycerin(NG in the nitrocellulose matrix and organic solvents leads to higher diffusion rates. This results in continued emissions of VOCs and HAPs. Conventional polymers tend to partition within the propellant matrix. In other words, localized mixing can occur between the polymer and underlying propellant. This is due to solvent induced softening of the polymer vehicle over the propellant grain. In effect this creates a path where migration can occur. Since nitrate esters, like NG, are relatively small, it can exude to the surface and create a highly unstable and dangerous situation for the warfighter. Curable polymers do not suffer from this partitioning due to “melting” because no VOC solvents are present. They remain surface coated. The small scale characterization testing, such as closed bomb testing, small scale sensitivity, thermal stability, and

  3. Calculation for Primary Combustion Characteristics of Boron-Based Fuel-Rich Propellant Based on BP Neural Network

    Directory of Open Access Journals (Sweden)

    Wu Wan'e

    2012-01-01

    Full Text Available A practical scheme for selecting characterization parameters of boron-based fuel-rich propellant formulation was put forward; a calculation model for primary combustion characteristics of boron-based fuel-rich propellant based on backpropagation neural network was established, validated, and then was used to predict primary combustion characteristics of boron-based fuel-rich propellant. The results show that the calculation error of burning rate is less than ±7.3%; in the formulation range (hydroxyl-terminated polybutadiene 28%–32%, ammonium perchlorate 30%–35%, magnalium alloy 4%–8%, catocene 0%–5%, and boron 30%, the variation of the calculation data is consistent with the experimental results.

  4. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties.

    Science.gov (United States)

    Swanson, Jeffrey W; Easter, Michele M; Robertson, Allison G; Swartz, Marvin S; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-06-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. Project HOPE—The People-to-People Health Foundation, Inc.

  5. The environmental behavior and chemical fate of energetic compounds (TNT, RDX, tetryl) in soil and plant systems

    International Nuclear Information System (INIS)

    Cataldo, D.A.; Harvey, S.D.; Fellows, R.J.

    1993-06-01

    Munitions materials can accumulate or cycle in terrestrial environs at production and manufacturing facilities and thus pose potential heath and environmental concerns. To address questions related to food chain accumulation, the environmental behavior of energetic compounds (2,4,6-trinitrotoluene,TNT; hexahydro-1,3,5-trinitro-1,3,5-triazine, RDX; 2,4,6-trinitrophenylmethylnitramine, tetryl) was evaluated. Emphasis was placed on determining the potential for soil/plant transfer of munitions residues, translocation and distribution within the plant, the extent to which compounds were metabolized following accumulation, and the chemical nature and form of accumulated residues. Both TNT and tetryl undergo extensive chemical transformation in soil, forming aminodinitrotoluene isomers and N-methyl-2,4,6-trinitroaniline residues, respectively, along with a series of unknowns. After 60 days, only 30% of the amended TNT and 8% of the amended tetryl remained unchanged in the soil. In contrast, 78% of the soil-amended RDX remained unchanged after 60 days. After 60 days, plants grown in soils containing 10 ppm residues contained from 5 μg TNT/g to 600 μg RDX/G fresh wt. tissue. TNT and tetryl residues were primarily accumulated in roots (75%), while RDX was concentrated in leaves and seed. The principal transport form for TNT (root to shoot) was an acid labile conjugate of aminodinitrotoluene; RDX was transported unchanged. On accumulation in roots and leaves, highly polar and non-extractable TNT metabolites dominated, with the aminodinitrotoluene isomers accounting for less than 20% of the residues present. Only a few percent were present as the parent TNT. RDX was partitioned similarly to TNT, with 8 to 30% of the RDX appearing as polar metabolites, 20--50% as parent RDX, and the balance as non-extractable residues. Tetryl was metabolized to N-methyl-2,4,6-trinitroaniline and a variety of polar metabolites

  6. Rheokinetic Analysis of Hydroxy Terminated Polybutadiene Based Solid Propellant Slurry

    Directory of Open Access Journals (Sweden)

    Abhay K Mahanta

    2010-01-01

    Full Text Available The cure kinetics of propellant slurry based on hydroxy-terminated polybutadiene (HTPB and toluene diisocyanate (TDI polyurethane reaction has been studied by viscosity build up method. The viscosity (ɳ–time (t plots conform to the exponential function ɳ = aebt, where a & b are empirical constants. The rate constants (k for viscosity build up at various shear rate (rpm, evaluated from the slope of dɳ/dt versus ɳ plots at different temperatures, were found to vary from 0.0032 to 0.0052 min-1. It was observed that the increasing shear rate did not have significant effect on the reaction rate constants for viscosity build up of the propellant slurry. The activation energy (Eɳ, calculated from the Arrhenius plots, was found to be 13.17±1.78 kJ mole-1, whereas the activation enthalpy (∆Hɳ* and entropy (∆Sɳ* of the propellant slurry, calculated from Eyring relationship, were found to be 10.48±1.78 kJ mole-1 and –258.51± 5.38 J mole-1K-1, respectively. The reaction quenching temperature of the propellant slurry was found to be -9 ° C, based upon the experimental data. This opens up an avenue for a “freeze-and-store”, then “warm-up and cast”, mode of manufacturing of very large solid rocket propellant grains.

  7. On the combustion mechanisms of ZrH2 in double-base propellant.

    Science.gov (United States)

    Yang, Yanjing; Zhao, Fengqi; Yuan, Zhifeng; Wang, Ying; An, Ting; Chen, Xueli; Xuan, Chunlei; Zhang, Jiankan

    2017-12-13

    Metal hydrides are regarded as a series of promising hydrogen-supplying fuel for solid rocket propellants. Their effects on the energetic and combustion performances of propellants are closely related to their reaction mechanisms. Here we report a first attempt to determine the reaction mechanism of ZrH 2 , a high-density metal hydride, in the combustion of a double-base propellant to evaluate its potential as a fuel. ZrH 2 is determined to possess good resistance to oxidation by nitrocellulose and nitroglycerine. Thus its combustion starts with dehydrogenation to generate H 2 and metallic Zr. Subsequently, the newly formed Zr and H 2 participate in the combustion and, especially, Zr melts and then combusts on the burning surface which favors the heat feedback to the propellant. This phenomenon is completely different from the combustion behavior of the traditional fuel Al, where the Al particles are ejected off the burning surface of the propellant to get into the luminous flame zone to burn. The findings in this work validate the potential of ZrH 2 as a hydrogen-supplying fuel for double-base propellants.

  8. Evaluation of the metabolic fate of munitions material (TNT & RDX) in plant systems and initial assessment of material interaction with plant genetic material. Validation of the metabolic fate of munitions materials (TNT, RDX) in mature crops

    Energy Technology Data Exchange (ETDEWEB)

    Fellows, R.J.; Harvey, S.D.; Cataldo, D.A.

    1995-09-01

    The goals of this effort were to confirm and expand data related to the behavior and impacts of munitions residues upon human food chain components. Plant species employed included corn (Zea mays), alfalfa (Medicago sativa). spinach (Spinacea oleraceae), and carrot (Daucus carota). Plants were grown from seed to maturity (70 to 120 days) in a low-fertility soil (Burbank) amended with either {sup 14}C-TNT or {sup 14}C-RDX at which time they were harvested and analyzed for munitions uptake, partitioning, and chemical form of the munition or munition-metabolite. All four of the plant species used in this study accumulated the {sup 14}C-TNT- and RDX-derived label. The carrot, alfalfa, and corn demonstrated a higher percentage of label retained in the roots (62, 73, and 83% respectively). The spinach contained less activity in its root (36%) but also contained the highest TNT specific activity observed (>4600 jig TNT equivalents/g dry wt.). The specific uptake values of RDX for the spinach and alfalfa were comparable to those previously reported for wheat and bean (314 to 590 {mu}g RDX-equivalents/g dry wt. respectively). An exception to this may be the carrot where the specific activity was found to exceed 4200 {mu}g RDX-equivalents/g dry wt. in the shoot. The total accumulation of TNT by the plants ranged from 1.24% for the spinach to 2.34% for the carrot. The RDX plants ranging from 15% for the spinach to 37% for the carrot. There was no identifiable TNT or amino dinitrotoluene (ADNT) isomers present in the plants however, the parent RDX compound was found at significant levels in the shoot of alfalfa (> 1 80 {mu}g/g) and corn (>18 {mu}g/g).

  9. Gun Shows and Gun Violence: Fatally Flawed Study Yields Misleading Results

    Science.gov (United States)

    Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A.

    2010-01-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled “The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas” outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors’ prior research. The study should not be used as evidence in formulating gun policy. PMID:20724672

  10. Encyclopedia of Gun Control and Gun Rights.

    Science.gov (United States)

    Utter, Glenn H.

    This reference volume provides information on gun control and gun rights, including resources on the debate surrounding the Second Amendment and individuals and organizations focused on gun issues, along with statutes, court cases, events, and publications surrounding this current topic. Highlighted are the important organizations and their…

  11. Integrated Data Collection Analysis (IDCA) Program - RDX Standard Data Set 2

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Phillips, Jason J. [Air Force Research Lab. (AFRL), Tyndall Air Force Base, FL (United States); Shelley, Timothy J. [Applied Research Associates, Tyndall Air Force Base, FL (United States); Reyes, Jose A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-02-20

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, from testing the second time in the Proficiency Test. This RDX testing (Set 2) compared to the first (Set 1) was found to have about the same impact sensitivity, have more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity.

  12. Burning Characteristics of Ammonium-Nitrate-Based Composite Propellants with a Hydroxyl-Terminated Polybutadiene/Polytetrahydrofuran Blend Binder

    Directory of Open Access Journals (Sweden)

    Makoto Kohga

    2012-01-01

    Full Text Available Ammonium-nitrate-(AN- based composite propellants prepared with a hydroxyl-terminated polybutadiene (HTPB/polytetrahydrofuran (PTHF blend binder have unique thermal decomposition characteristics. In this study, the burning characteristics of AN/HTPB/PTHF propellants are investigated. The specific impulse and adiabatic flame temperature of an AN-based propellant theoretically increases with an increase in the proportion of PTHF in the HTPB/PTHF blend. With an AN/HTPB propellant, a solid residue is left on the burning surface of the propellant, and the shape of this residue is similar to that of the propellant. On the other hand, an AN/HTPB/PTHF propellant does not leave a solid residue. The burning rates of the AN/HTPB/PTHF propellant are not markedly different from those of the AN/HTPB propellant because some of the liquefied HTPB/PTHF binder cover the burning surface and impede decomposition and combustion. The burning rates of an AN/HTPB/PTHF propellant with a burning catalyst are higher than those of an AN/HTPB propellant supplemented with a catalyst. The beneficial effect of the blend binder on the burning characteristics is clarified upon the addition of a catalyst. The catalyst suppresses the negative influence of the liquefied binder that covers the burning surface. Thus, HTPB/PTHF blend binders are useful in improving the performance of AN-based propellants.

  13. Two-stage plasma gun based on a gas discharge with a self-heating hollow emitter.

    Science.gov (United States)

    Vizir, A V; Tyunkov, A V; Shandrikov, M V; Oks, E M

    2010-02-01

    The paper presents the results of tests of a new compact two-stage bulk gas plasma gun. The plasma gun is based on a nonself-sustained gas discharge with an electron emitter based on a discharge with a self-heating hollow cathode. The operating characteristics of the plasma gun are investigated. The discharge system makes it possible to produce uniform and stable gas plasma in the dc mode with a plasma density up to 3x10(9) cm(-3) at an operating gas pressure in the vacuum chamber of less than 2x10(-2) Pa. The device features high power efficiency, design simplicity, and compactness.

  14. Two-stage plasma gun based on a gas discharge with a self-heating hollow emitter

    International Nuclear Information System (INIS)

    Vizir, A. V.; Tyunkov, A. V.; Shandrikov, M. V.; Oks, E. M.

    2010-01-01

    The paper presents the results of tests of a new compact two-stage bulk gas plasma gun. The plasma gun is based on a nonself-sustained gas discharge with an electron emitter based on a discharge with a self-heating hollow cathode. The operating characteristics of the plasma gun are investigated. The discharge system makes it possible to produce uniform and stable gas plasma in the dc mode with a plasma density up to 3x10 9 cm -3 at an operating gas pressure in the vacuum chamber of less than 2x10 -2 Pa. The device features high power efficiency, design simplicity, and compactness.

  15. Calculation of marine propeller static strength based on coupled BEM/FEM

    Directory of Open Access Journals (Sweden)

    YE Liyu

    2017-10-01

    Full Text Available [Objectives] The reliability of propeller stress has a great influence on the safe navigation of a ship. To predict propeller stress quickly and accurately,[Methods] a new numerical prediction model is developed by coupling the Boundary Element Method(BEMwith the Finite Element Method (FEM. The low order BEM is used to calculate the hydrodynamic load on the blades, and the Prandtl-Schlichting plate friction resistance formula is used to calculate the viscous load. Next, the calculated hydrodynamic load and viscous correction load are transmitted to the calculation of the Finite Element as surface loads. Considering the particularity of propeller geometry, a continuous contact detection algorithm is developed; an automatic method for generating the finite element mesh is developed for the propeller blade; a code based on the FEM is compiled for predicting blade stress and deformation; the DTRC 4119 propeller model is applied to validate the reliability of the method; and mesh independence is confirmed by comparing the calculated results with different sizes and types of mesh.[Results] The results show that the calculated blade stress and displacement distribution are reliable. This method avoids the process of artificial modeling and finite element mesh generation, and has the advantages of simple program implementation and high calculation efficiency.[Conclusions] The code can be embedded into the code of theoretical and optimized propeller designs, thereby helping to ensure the strength of designed propellers and improve the efficiency of propeller design.

  16. Frictional properties of single crystals HMX, RDX and PETN explosives

    International Nuclear Information System (INIS)

    Wu, Y.Q.; Huang, F.L.

    2010-01-01

    The frictional properties of single crystals of cyclotetramethylene tetranitramine (HMX), cyclotrimethylene trinitramine (RDX) and pentaerythritol tetranitrate (PETN) secondary explosives are examined using a sensitive friction machine. The explosive crystals used for the measurements are at least 3.5 mm wide. The friction coefficients between crystals of the same explosive (i.e., HMX on HMX, etc.), crystals of different explosives (i.e., HMX on RDX, etc.), and each explosive and a well-polished gauge steel surface are determined. The frictional surfaces are also studied under an environmental scanning electron microscope (ESEM) to analyze surface microstructural changes under increasing loading forces. The friction coefficients vary considerably with increasing normal loading forces and are particularly sensitive to slider shapes, crystal roughness and the mechanical properties of both the slider and the sample. With increasing loading forces, most friction experiments show surface damage, consisting of grooves, debris, and nano-particles, on both the slider and sample. In some cases, a strong evidence of a localized molten state is found in the central region of the friction track. Possible mechanisms that affect the friction coefficient are discussed based on microscopic observations.

  17. Shock-induced fast reactions of zinc nanoparticles and RDX

    International Nuclear Information System (INIS)

    Xue Mian; Wu Jinghe; Ye Song; Yang Xiangdong; Hu Dong; Wang Yanping; Zhu Wenjun; Li Chengbing

    2008-01-01

    Fast reactions of zinc nanoparticles and RDX were investigated in normal incident shock waves. The emergence time and emission spectra intensity of partial products such as NO 2 , H, C 2 , O, CO, CH 2 O, CO 2 , H 2 O and ZnO were observed by a TDS5054 oscilloscope. The results indicate that NO 2 appears first in each experiment, which is in agreement with the theoretical results. The addition of zinc nanoparticles to RDX can not only shorten the ignition delay time by 20% but also double the shockwave diffusion velocity to 2180 ± 50 m s -1 and triple the temperature to 2020 ± 60 K. The emergence time of products shortens by around 10-40% and the emission spectra intensity of H 2 O and CH 2 O rises by about three times and one times, respectively. CO 2 , H 2 O and O 2 in various concentrations were introduced into the zinc-RDX reaction, respectively, which indicate that O 2 made the ignition delay time shorten by over 30%, the effect of H 2 O was not prominent while CO 2 made the ignition delay time lag by around 30%. The results indicate that the Zn-O 2 reaction mainly occurs in O 2 , CO 2 and H 2 O

  18. Application of 13C and 15N stable isotope probing to characterize RDX degrading microbial communities under different electron-accepting conditions

    International Nuclear Information System (INIS)

    Cho, Kun-Ching; Lee, Do Gyun; Fuller, Mark E.; Hatzinger, Paul B.; Condee, Charles W.; Chu, Kung-Hui

    2015-01-01

    Highlights: • SIP characterized RDX-degrading communities under different e-accepting conditions. • Dominant RDX degradation pathways differed under different e-accepting conditions. • More complete detoxification of RDX occurred under methanogenic and sulfate-reducing conditions than under manganese(IV) and iron(III)-reducing conditions. - Abstract: This study identified microorganisms capable of using the explosive hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) or its metabolites as carbon and/or nitrogen sources under different electron-accepting conditions using 13 C and 15 N stable isotope probing (SIP). Mesocosms were constructed using groundwater and aquifer solids from an RDX-contaminated aquifer. The mesocosms received succinate as a carbon source and one of four electron acceptors (nitrate, manganese(IV), iron(III), or sulfate) or no additional electron acceptor (to stimulate methanogenesis). When RDX degradation was observed, subsamples from each mesocosm were removed and amended with 13 C 3 - or ring- 15 N 3 -, nitro- 15 N 3 -, or fully-labeled 15 N 6 -RDX, followed by additional incubation and isolation of labeled nucleic acids. A total of fifteen 16S rRNA sequences, clustering in α- and γ-Proteobacteria, Clostridia, and Actinobacteria, were detected in the 13 C-DNA fractions. A total of twenty seven sequences were derived from different 15 N-DNA fractions, with the sequences clustered in α- and γ-Proteobacteria, and Clostridia. Interestingly, sequences identified as Desulfosporosinus sp. (in the Clostridia) were not only observed to incorporate the labeled 13 C or 15 N from labeled RDX, but also were detected under each of the different electron-accepting conditions. The data suggest that 13 C- and 15 N-SIP can be used to characterize microbial communities involved in RDX biodegradation, and that the dominant pathway of RDX biodegradation may differ under different electron-accepting conditions

  19. Effects of hydrogen bonds on solid state TATB, RDX, and DATB under high pressures

    International Nuclear Information System (INIS)

    Guo Feng; Hu Hai-Quan; Zhang Hong; Cheng Xin-Lu

    2014-01-01

    To probe the behavior of hydrogen bonds in solid energetic materials, we conduct ReaxFF and SCC–DFTB molecular dynamics simulations of crystalline TATB, RDX, and DATB. By comparing the intra- and inter-molecular hydrogen bonding rates, we find that the crystal structures are stabilized by inter-molecular hydrogen bond networks. Under high-pressure, the inter- and intra-molecular hydrogen bonds in solid TATB and DATB are nearly equivalent. The hydrogen bonds in solid TATB and DATB are much shorter than in solid RDX, which suggests strong hydrogen bond interactions existing in these energetic materials. Stretching of the C–H bond is observed in solid RDX, which may lead to further decomposition and even detonation. (condensed matter: structural, mechanical, and thermal properties)

  20. High time resolution beam-based measurement of the rf-to-laser jitter in a photocathode rf gun

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2014-03-01

    Full Text Available Characterizing the rf-to-laser jitter in the photocathode rf gun and its possible origins is important for improving the synchronization and beam quality of the linac based on the photocathode rf gun. A new method based on the rf compression effect in the photocathode rf gun is proposed to measure the rf-to-laser jitter in the gun. By taking advantage of the correlation between the rf compression and the laser injection phase, the error caused by the jitter of the accelerating field in the gun is minimized and thus 10 fs time resolution is expected. Experimental demonstration at the Tsinghua Thomson scattering x-ray source with a time resolution better than 35 fs is reported in this paper. The experimental results are successfully used to obtain information on the possible cause of the jitter and the accompanying drifts.

  1. Electromagnetic Guns versus Conventional Guns - a performance comparison

    NARCIS (Netherlands)

    Reus, N.M. de; Weijden, J. van der

    1993-01-01

    Performance improvement is one of the key issues of Electromagnetic gun systems compared to conventional gun systems. Due to higher muzzle velocities, the gun's fire control computer will be able to predict the target's future position more accurately because prediction time will be smaller. In this

  2. Simulation of two-dimensional interior ballistics model of solid propellant electrothermal-chemical launch with discharge rod plasma generator

    Directory of Open Access Journals (Sweden)

    Yan-jie Ni

    2017-08-01

    Full Text Available Instead of the capillary plasma generator (CPG, a discharge rod plasma generator (DRPG is used in the 30 mm electrothermal-chemical (ETC gun to improve the ignition uniformity of the solid propellant. An axisymmetric two-dimensional interior ballistics model of the solid propellant ETC gun (2D-IB-SPETCG is presented to describe the process of the ETC launch. Both calculated pressure and projectile muzzle velocity accord well with the experimental results. The feasibility of the 2D-IB-SPETCG model is proved. Depending on the experimental data and initial parameters, detailed distribution of the ballistics parameters can be simulated. With the distribution of pressure and temperature of the gas phase and the propellant, the influence of plasma during the ignition process can be analyzed. Because of the radial flowing plasma, the propellant in the area of the DRPG is ignited within 0.01 ms, while all propellant in the chamber is ignited within 0.09 ms. The radial ignition delay time is much less than the axial delay time. During the ignition process, the radial pressure difference is less than 5  MPa at the place 0.025 m away from the breech. The radial ignition uniformity is proved. The temperature of the gas increases from several thousand K (conventional ignition to several ten thousand K (plasma ignition. Compare the distribution of the density and temperature of the gas, we know that low density and high temperature gas appears near the exits of the DRPG, while high density and low temperature gas appears at the wall near the breech. The simulation of the 2D-IB-SPETCG model is an effective way to investigate the interior ballistics process of the ETC launch. The 2D-IB-SPETC model can be used for prediction and improvement of experiments.

  3. Passive Biobarrier for Treating Co-mingled Perchlorate and RDX in Groundwater at an Active Range

    Science.gov (United States)

    2016-05-12

    16S rRNA sequences were derived. These sequences resided in four major clusters: Actinobacteria (Eggerthella), -Proteobacteria (unclassified...Proteobacteria, Actinobacteria , -Proteobacteria and Clostridia) have been previously reported to biodegrade RDX directly, or to contribute to RDX...detected primarily under manganese-reducing conditions (with one under sulfate- reducing conditions) in our study, remain unclear. Actinobacteria are

  4. Perancangan Propeler Self-Propelled Barge

    Directory of Open Access Journals (Sweden)

    Billy Teguh kurniawan

    2013-03-01

    Full Text Available Makalah ini menyampaikan suatu penelitian tentang perancangan propeler yang optimal beserta pemilihan daya mesin yang efisien pada self-propelled barge dengan memperhitungkan besarnya nilai tahanan dari barge tersebut. Dengan penambahan sistem propulsi, diharapkan barge dapat beroperasi dengan lebih efisien dibandingkan saat barge beroperasi menggunakan sistem towing atau ditarik tug boat. Perhitungan tahanan barge dilakukan menggunakan metode Holtrop dan Guldhammer-Harvald sehingga dapat diperhi-tungkan geometri dan jenis propeler yang optimal beserta daya mesin yang efisien untuk barge. Propeler yang dianalisis adalah propeler tipe B-Troost Series, sedangkan variasi yang dilakukan untuk perencanaan propeler pada kajian ini adalah variasi putaran propeler pada rentang antara 310-800 rpm, serta variasi jumlah daun pada rentang tiga, empat, lima, dan enam. Besarnya nilai tahanan self-propelled barge untuk metode Holtrop adalah 105.91 kilonewton, sedangkan hasil per-hitungan dari metode Guldhammer-Harvald didapatkan nilai sebesar 109.14 kilonewton. Tipe propeler yang dipilih setelah dilakukan uji kavitasi adalah tipe Troost Series B4-40, dengan diameter sebesar 2.1 m, efisiensi sebesar 0.421, pitch ratio se-besar 0.591, dengan putaran propeler 400 rpm. Daya mesin yg dibutuhkan barge pada kondisi maksimum (BHPMCR sebesar 1669.5 HP. Dengan mempertimbangkan daya tersebut, maka dipilih mesin jenis Caterpillar tipe Marine 3516B yang mem-punyai daya maksimum sebesar 1285 kilowatt atau 1722.5 horsepower dengan putaran mesin sebesar 1200 rpm

  5. The Effects of Gun Ownership Rates and Gun Control Laws on Suicide Rates

    OpenAIRE

    Mark Gius

    2011-01-01

    The purpose of the present study is to determine the effects of gun control laws and gun ownership rates on state-level suicide rates. Using the most recent data on suicide rates, gun control measures, and gun ownership rates, the results of the present study suggest that states that require handgun permits have lower gun-related suicide rates, and states that have higher gun ownership rates have higher gun-related suicide rates. Regarding non-gun suicides, results suggest that stricter gun c...

  6. Reactive simulation of the chemistry behind the condensed-phase ignition of RDX from hot spots.

    Science.gov (United States)

    Joshi, Kaushik L; Chaudhuri, Santanu

    2015-07-28

    Chemical events that lead to thermal initiation and spontaneous ignition of the high-pressure phase of RDX are presented using reactive molecular dynamics simulations. In order to initiate the chemistry behind thermal ignition, approximately 5% of RDX crystal is subjected to a constant temperature thermal pulse for various time durations to create a hot spot. After application of the thermal pulse, the ensuing chemical evolution of the system is monitored using reactive molecular dynamics under adiabatic conditions. Thermal pulses lasting longer than certain time durations lead to the spontaneous ignition of RDX after an incubation period. For cases where the ignition is observed, the incubation period is dominated by intermolecular and intramolecular hydrogen transfer reactions. Contrary to the widely accepted unimolecular models of initiation chemistry, N-N bond dissociations that produce NO2 species are suppressed in the condensed phase. The gradual temperature and pressure increase in the incubation period is accompanied by the accumulation of short-lived, heavier polyradicals. The polyradicals contain intact triazine rings from the RDX molecules. At certain temperatures and pressures, the polyradicals undergo ring-opening reactions, which fuel a series of rapid exothermic chemical reactions leading to a thermal runaway regime with stable gas-products such as N2, H2O and CO2. The evolution of the RDX crystal throughout the thermal initiation, incubation and thermal runaway phases observed in the reactive simulations contains a rich diversity of condensed-phase chemistry of nitramines under high-temperature/pressure conditions.

  7. Gun Safety

    Science.gov (United States)

    Many U.S. households have guns, but they can cause harm if not handled properly. Here are some things you can do to keep yourself and ... safe: Teach children that they shouldn't touch guns and that if they see a gun, to ...

  8. Shock-induced fast reactions of zinc nanoparticles and RDX

    Energy Technology Data Exchange (ETDEWEB)

    Xue Mian; Wu Jinghe; Ye Song; Yang Xiangdong [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610065 (China); Hu Dong; Wang Yanping; Zhu Wenjun; Li Chengbing [National Key Laboratory for Shock Wave and Detonation Physics Research, Institute of Fluid Physics, CAEP, Mianyang 621900 (China)], E-mail: mi-anxue@163.com

    2008-02-21

    Fast reactions of zinc nanoparticles and RDX were investigated in normal incident shock waves. The emergence time and emission spectra intensity of partial products such as NO{sub 2}, H, C{sub 2}, O, CO, CH{sub 2}O, CO{sub 2}, H{sub 2}O and ZnO were observed by a TDS5054 oscilloscope. The results indicate that NO{sub 2} appears first in each experiment, which is in agreement with the theoretical results. The addition of zinc nanoparticles to RDX can not only shorten the ignition delay time by 20% but also double the shockwave diffusion velocity to 2180 {+-} 50 m s{sup -1} and triple the temperature to 2020 {+-} 60 K. The emergence time of products shortens by around 10-40% and the emission spectra intensity of H{sub 2}O and CH{sub 2}O rises by about three times and one times, respectively. CO{sub 2}, H{sub 2}O and O{sub 2} in various concentrations were introduced into the zinc-RDX reaction, respectively, which indicate that O{sub 2} made the ignition delay time shorten by over 30%, the effect of H{sub 2}O was not prominent while CO{sub 2} made the ignition delay time lag by around 30%. The results indicate that the Zn-O{sub 2} reaction mainly occurs in O{sub 2}, CO{sub 2} and H{sub 2}O.

  9. Magnetized gun experiments

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Henins, I.; Hoida, H.W.; Marshall, J.; Sherwood, A.R.

    1981-01-01

    In the Los Alamos Magnetized Gun Experiment we are attempting to produce a compact torus in a manner similar to an earlier experiment of Alfven. In our experiment a solenoidal coil is placed inside the inner electrode of a coaxial plasma gun. This coil produces an axial magnetic field inside the inner electrode which diverges and becomes a largely radial field in front of the gun muzzle. The idea is that when the gun is fired, the plasma escaping from the gun stretches these radial fields along the axial direction away from the gun, and these field lines can reconnect behind the plasma forming the poloidal field of the compact torus. The magnetic field generated by the gun current becomes the toroidal field and the major axis of the compact torus will be the same as the axis of the coaxial gun. Recent interest in this possible method of compact torus generation was stimulated by C. Hartman, and the approach is also being pursued in the field-reversed plasma gun experiment at LLL

  10. The electromagnetic rocket gun - a means to reach ultrahigh velocities

    International Nuclear Information System (INIS)

    Winterberg, F.

    1983-01-01

    A novel kind of electromagnetic launcher for the acceleration of multigram-size macroparticles, up to velocities required for impact fusion, is proposed. The novel launcher concept combines the efficiency of a gun with the much higher velocities attainable by a rocket. In the proposed concept a rocket-like projectile is launched inside a gun barrel, drawing its energy from a travelling magnetic wave. The travelling magnetic wave heats and ionizes the exhaust jet of the rocket. As a result, the projectile i propelled both by the recoil from the jet and the magnetic pressure of the travelling magnetic wave. In comparison to magnetic linear accelerators, accelerating either superconducting or ferromagnetic projectiles, the proposed concept has several important advantages. First, the exhaust jet is much longer than the rocket-like projectile and which permits a much longer switching time to turn on the travelling magnetic wave. Second, the proposed concept does not require superconducting projectiles, or projectiles made from expensive ferromagnetic material. Third, unlike in railgun accelerators, the projectile can be kept away from the wall, and thereby can reach much larger velocities. (orig.)

  11. LCLS Gun Solenoid Design Considerations

    International Nuclear Information System (INIS)

    Schmerge, John

    2010-01-01

    The LCLS photocathode rf gun requires a solenoid immediately downstream for proper emittance compensation. Such a gun and solenoid have been operational at the SSRL Gun Test Facility (GTF) for over eight years. Based on magnetic measurements and operational experience with the GTF gun solenoid multiple modifications are suggested for the LCLS gun solenoid. The modifications include adding dipole and quadrupole correctors inside the solenoid, increasing the bore to accommodate the correctors, decreasing the mirror plate thickness to allow the solenoid to move closer to the cathode, cutouts in the mirror plate to allow greater optical clearance with grazing incidence cathode illumination, utilizing pancake coil mirror images to compensate the first and second integrals of the transverse fields and incorporating a bipolar power supply to allow for proper magnet standardization and quick polarity changes. This paper describes all these modifications plus the magnetic measurements and operational experience leading to the suggested modifications.

  12. Camouflaged Collectives: Managing Stigma and Identity at Gun Events

    Directory of Open Access Journals (Sweden)

    Sarah Jane Blithe

    2017-02-01

    Full Text Available Gun violence persists in the United States, claiming lives and escalating healthcare costs. This article seeks to contribute to social justice work on the “gun problem” by studying gun collectives. To understand gun culture and to identify gun violence reduction strategies, we study places where gun owners organize – legal (and sometimes illegal settings that facilitate dialogue about gun issues. Based on participant observation and collaborative event ethnography at gun shows and a private shooting party, this analysis presents findings about the practices gun collective members use to manage stigma. We conclude that when participants in gun events attempt to subvert core stigma through everyday stigma management practices, they effectively facilitate the unfettered exchange of potentially dangerous goods, promote the invisibility of oppressive structures, and normalize violence.

  13. Gun Safety (For Kids)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Gun Safety KidsHealth / For Kids / Gun Safety What's in ... from guns outside the home. If You Have Guns in Your Home If your parents keep guns ...

  14. Research on Miniature Calibre Rail-Guns for the Mechanical Arm

    Directory of Open Access Journals (Sweden)

    Ronggang Cao

    2017-01-01

    Full Text Available Rail-gun should not only be used to military applications, but also can be developed as applications in the civilian aspects of the market. With the development of the electromagnetic launch technology, based on the similarity theory, using the existing rail-gun model to guide the construction of more economical miniature calibre rail-guns, and apply it in some machinery and equipment, this idea will open up a wider rail-gun application space. This article will focus on the feasibility of application of miniature calibre rail-guns in the mechanical arm. This paper designs the schematic diagram, then theoretical analyzes force conditions of the armature in the mechanical arm, calculates the possible range of the current amplitude and so on. The existing rail-gun model can be used to guides design the circuit diagram of the miniature calibre rail-gun. Based on the similarity theory and many simulation experiments, designed the experimental parameters of a miniature rail-gun and analyzed the current, Lorentz force, velocity, and location of the existing rail-gun and miniature rail-gun. The results show that the rail-gun launching technology applied to robot arms is feasibility. The application of miniature calibre rail-guns in the mechanical arm will benefit to the further development of rail-guns.

  15. High-brightness electron guns for linac-based light sources

    International Nuclear Information System (INIS)

    Lewellen, J.W.

    2004-01-01

    Most proposed linac-based light sources, such as single-pass free-electron lasers and energy-recovery-linacs, require very high-brightness electron beams in order to achieve their design performance. These beam requirements must be achieved not on an occasional basis, but rather must be met by every bunch produced by the source over extended periods of time. It is widely assumed that the beam source will be a photocathode electron gun; the selection of accelerator technique (e.g., dc or rf) for the gun is more dependent on the application.The current state of the art of electron beam production is adequate but not ideal for the first generation of linac-based light sources, such as the Linac Coherent Light Source (LCLS) x-ray free-electron laser (X-FEL). For the next generation of linac-based light sources, an order of magnitude reduction in the transverse electron beam emittance is required to significantly reduce the cost of the facility. This is beyond the present state of the art, given the other beam properties that must be maintained. The requirements for current and future linac-based light source beam sources are presented here, along with a review of the present state of the art. A discussion of potential paths towards meeting future needs is presented at the conclusion.

  16. State Gun Policy and Cross-State Externalities: Evidence from Crime Gun Tracing

    OpenAIRE

    Brian Knight

    2013-01-01

    This paper provides a theoretical and empirical analysis of cross-state externalities associated with gun regulations in the context of the gun trafficking market. Using gun tracing data, which identify the source state for crime guns recovered in destination states, we find that firearms in this market tend to flow from states with weak gun laws to states with strict gun laws, satisfying a necessary condition for the existence of cross-state externalities in the theoretical model. We also fi...

  17. MEMS-Based Solid Propellant Rocket Array Thruster

    Science.gov (United States)

    Tanaka, Shuji; Hosokawa, Ryuichiro; Tokudome, Shin-Ichiro; Hori, Keiichi; Saito, Hirobumi; Watanabe, Masashi; Esashi, Masayoshi

    The prototype of a solid propellant rocket array thruster for simple attitude control of a 10 kg class micro-spacecraft was completed and tested. The prototype has 10×10 φ0.8 mm solid propellant micro-rockets arrayed at a pitch of 1.2 mm on a 20×22 mm substrate. To realize such a dense array of micro-rockets, each ignition heater is powered from the backside of the thruster through an electrical feedthrough which passes along a propellant cylinder wall. Boron/potassium nitrate propellant (NAB) is used with/without lead rhodanide/potassium chlorate/nitrocellulose ignition aid (RK). Impulse thrust was measured by a pendulum method in air. Ignition required electric power of at least 3 4 W with RK and 4 6 W without RK. Measured impulse thrusts were from 2×10-5 Ns to 3×10-4 Ns after the calculation of compensation for air dumping.

  18. Effects of Aluminum Powder on Ignition Performance of RDX, HMX, and CL-20 Explosives

    Directory of Open Access Journals (Sweden)

    Xiaoxiang Mao

    2018-01-01

    Full Text Available As a kind of high explosives, aluminized explosive cannot release the energy maximumly, which is a key problem. Using DTA-TG equipment, the ignition performance of three kinds of aluminized explosives (RDX, HMX, and CL-20 with different mass percentages of aluminum powder (0%, 10 wt.%, 20 wt.%, and 30 wt.% was investigated. The results showed that the energy release of the HMX/Al composite explosive with 10 wt.%, 20 wt.%, and 30 wt.% aluminum powder was only equivalent to 80%, 65%, and 36% of pure HMX, respectively. It was similar to RDX/Al and CL-20/Al composite explosives, except the CL-20/Al mixture with 10% aluminum powder. Rather than participating in the ignition and combustion, the aluminum powder does effect the complete reaction of RDX, HMX, and CL-20 in the initial stage of ignition or in the lower temperature area of the boundary.

  19. RF Electron Gun with Driven Plasma Cathode

    CERN Document Server

    Khodak, Igor

    2005-01-01

    It's known that RF guns with plasma cathodes based on solid-state dielectrics are able to generate an intense electron beam. In this paper we describe results of experimental investigation of the single cavity S-band RF gun with driven plasma cathode. The experimental sample of the cathode based on ferroelectric ceramics has been designed. Special design of the cathode permits to separate spatially processes of plasma development and electron acceleration. It has been obtained at RF gun output electron beam with particle energy ~500 keV, pulse current of 4 A and pulse duration of 80 ns. Results of experimental study of beam parameters are referred in. The gun is purposed to be applied as the intense electron beam source for electron linacs.

  20. New Electron Gun System for BEPCII

    CERN Document Server

    Liu, Bo; Long Chi, Yun; Zhang, Chuang

    2005-01-01

    The new electron gun system for BEPCII has been put into operation since Nov. 2004. The article describes the design, experiment and operation of this new system. The design current of the gun is 10 A for the pulse lengths of 1 ns, 2.5 ns and 1 μs with repetition rate of 50 Hz. The gun is operated with a pulsed high voltage power supply which can provide up to 200 kV high voltage. Computer simulations have been carried out in the design stage, including simulation of the gun geometry and beam transportation. Some important relation curves are obtained during the experiment. Two-bunch operation is available and some elementary tests have been performed. New scheme of the gun control system based on EPICS is also presented. The real operation shows that the design and manufacturing is basically successful.

  1. Shock initiation sensitivity and Hugoniot-based equation of state of Composition B obtained using in situ electromagnetic gauging

    International Nuclear Information System (INIS)

    Gibson, L L; Bartram, B D; Sheffield, S A; Gustavsen, R L; Brown, G W; Sandstrom, M M; Giambra, A M; Dattelbaum, D M; Handley, C A

    2014-01-01

    A series of gas gun-driven plate impact experiments were performed on vacuum melt-cast Composition B to obtain new Hugoniot states and shock sensitivity (run-distance-to-detonation) information. The Comp B (ρ 0 = 1.713 g/cm 3 ) consisted of 59.5% RDX, 39.5% TNT, and 1% wax, with ∼ 6.5% HMX in the RDX. The measured Hugoniot states were found to be consistent with earlier reports, with the compressibility on the shock adiabat softer than that of a 63% RDX material reported by Marsh.[4] The shock sensitivity was found to be more sensitive (shorter run distance to detonation at a given shock input condition) than earlier reports for Comp B-3 and a lower density (1.68-1.69 g/cm 3 ) Comp B formulation. The reactive flow during the shock-to-detonation transition was marked by heterogeneous, hot spot-driven growth both in and behind the leading shock front.

  2. Effect of Long Term Low-Level Gamma Radiation on Thermal Sensitivity of RDX/HMX Mixtures

    Science.gov (United States)

    1976-11-01

    1.1x10 R. It was concluded that the slight exothermic reaction before the 3^6 HMX polymorphic transition could be caused by a radiation-induced...Radiation on Thermal Sensitivity of RDX / HMX Mixtures 5. TYPE OF REPORT 4 PERIOD COVERED Final Report 6. PERFORMING ORG. REPORT NUMBER 7...and Identity by block number) Gamma radiation Weight loss HMX Impact sensitivity test RDX Vacuum stability test DTA Infrared spectrometry TGA

  3. Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Gulliford, Colwyn, E-mail: cg248@cornell.edu; Bartnik, Adam, E-mail: acb20@cornell.edu; Bazarov, Ivan; Dunham, Bruce; Cultrera, Luca [CLASSE, Cornell University, 161 Synchrotron Drive Ithaca, New York 14853-8001 (United States)

    2015-03-02

    We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (≥100 pC) beams produced in the DC gun-based Cornell energy recovery linac photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittances measured at 9–9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These results, previously thought achievable only with RF guns, demonstrate that DC gun based photoinjectors are capable of delivering beams with sufficient single bunch charge and beam quality suitable for many current and next generation accelerator projects such as Energy Recovery Linacs and Free Electron Lasers.

  4. Low cost manned Mars mission based on indigenous propellant production

    Science.gov (United States)

    Bruckner, A. P.; Cinnamon, M.; Hamling, S.; Mahn, K.; Phillips, J.; Westmark, V.

    1993-01-01

    The paper describes a low-cost approach to the manned exploration of Mars (which involves an unmanned mission followed two years later by a manned mission) based on near-term technologies and in situ propellant production. Particular attention is given to the basic mission architecture and its major components, including the orbital analysis, the unmanned segment, the Earth Return Vehicle, the aerobrake design, life sciences, guidance, communications, power, propellant production, the surface rovers, and Mars science. Also discussed are the cost per mission over an assumed 8-yr initiative.

  5. Plasma-filled diode based on the coaxial gun

    Science.gov (United States)

    Zherlitsyn, A. A.; Kovalchuk, B. M.; Pedin, N. N.

    2012-10-01

    The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.

  6. Plasma-filled diode based on the coaxial gun.

    Science.gov (United States)

    Zherlitsyn, A A; Kovalchuk, B M; Pedin, N N

    2012-10-01

    The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.

  7. Plasma-filled diode based on the coaxial gun

    International Nuclear Information System (INIS)

    Zherlitsyn, A. A.; Kovalchuk, B. M.; Pedin, N. N.

    2012-01-01

    The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.

  8. CFD SIMULATION FOR DEMILITARIZATION OF RDX IN A ROTARY KILN BY THERMAL DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    SI H. LEE

    2017-06-01

    Full Text Available Demilitarization requires the recovery and disposal of obsolete ammunition and explosives. Since open burning/detonation of hazardous waste has caused serious environmental and safety problems, thermal decomposition has emerged as one of the most feasible methods. RDX is widely used as a military explosive due to its high melting temperature and detonation power. In this work, the feasible conditions under which explosives can be safely incinerated have been investigated via a rotary kiln simulation. To solve this problem, phase change along with the reactions of RDX has been incisively analyzed. A global reaction mechanism consisting of condensed phase and gas phase reactions are used in Computational Fluid Dynamics simulation. User Defined Functions in FLUENT is utilized in this study to inculcate the reactions and phase change into the simulation. The results divulge the effect of temperature and the varying amounts of gas produced in the rotary kiln during the thermal decomposition of RDX. The result leads to the prospect of demilitarizing waste explosives to avoid the possibility of detonation.

  9. Phytoremediation of Composition-B Derived TNT and RDX in Herbaceous Plant-vegetated and Bare Lysimeters

    Science.gov (United States)

    2009-12-01

    ER D C TR -0 9- 10 Strategic Environmental Research and Development Program Phytoremediation of Composition-B Derived TNT and RDX in...Program ERDC TR-09-10 December 2009 Phytoremediation of Composition-B Derived TNT and RDX in Herbaceous Plant-vegetated and Bare Lysimeters Elly P. H...for U.S. Army Corps of Engineers Washington, DC 20314-1000 ERDC TR-09-10 ii Abstract: This report describes a study in which phytoremediation of

  10. Plasma-filled diode based on the coaxial gun

    Energy Technology Data Exchange (ETDEWEB)

    Zherlitsyn, A. A.; Kovalchuk, B. M.; Pedin, N. N. [Institute of High Current Electronics, 2/3 Academichesky Avenue, 634055 Tomsk (Russian Federation)

    2012-10-15

    The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of {>=}1 MeV at the current of Almost-Equal-To 100 kA was obtained in the experiments with a plasma-filled diode. The energy of Almost-Equal-To 5 kJ with the peak power of {>=}100 GW dissipated in the diode.

  11. 120 Hz Gun Review

    Energy Technology Data Exchange (ETDEWEB)

    Colby, E.

    2005-01-31

    The review was held at SLAC on September 11 and 12, 2001. Presentations concerning the thermal analysis, mechanical design, integration with the laser and accelerator, general beam dynamics considerations, a load lock mechanism, and symmetric power feed options comprised the review. Slides from these presentations are available elsewhere. The review committee was charged with evaluating the 120 Hz gun design including proposed load lock and power feed options and recommending improvements. Broader evaluation of the injector as a whole (including focusing and diagnostic systems that do no impact the envelope of the gun itself) is expected to be covered in a future review and will not be commented on here. In general, the long operational experience with four generations of s-band RF guns at numerous labs worldwide has led to considerable experience in design, fabrication, and operation aspects, and provides an excellent base on which to design the higher duty factor LCLS injector. While open questions remain on obtaining the design performance from these injectors, the microwave design of the gun has reached a state of relative maturity.

  12. The steady performance prediction of propeller-rudder-bulb system based on potential iterative method

    International Nuclear Information System (INIS)

    Liu, Y B; Su, Y M; Ju, L; Huang, S L

    2012-01-01

    A new numerical method was developed for predicting the steady hydrodynamic performance of propeller-rudder-bulb system. In the calculation, the rudder and bulb was taken into account as a whole, the potential based surface panel method was applied both to propeller and rudder-bulb system. The interaction between propeller and rudder-bulb was taken into account by velocity potential iteration in which the influence of propeller rotation was considered by the average influence coefficient. In the influence coefficient computation, the singular value should be found and deleted. Numerical results showed that the method presented is effective for predicting the steady hydrodynamic performance of propeller-rudder system and propeller-rudder-bulb system. Comparing with the induced velocity iterative method, the method presented can save programming and calculation time. Changing dimensions, the principal parameter—bulb size that affect energy-saving effect was studied, the results show that the bulb on rudder have a optimal size at the design advance coefficient.

  13. Temporal association between federal gun laws and the diversion of guns to criminals in Milwaukee.

    Science.gov (United States)

    Webster, Daniel W; Vernick, Jon S; Bulzacchelli, Maria T; Vittes, Katherine A

    2012-02-01

    The practices of licensed gun dealers can threaten the safety of urban residents by facilitating the diversion of guns to criminals. In 2003, changes to federal law shielded gun dealers from the release of gun trace data and provided other protections to gun dealers. The 14-month period during which the dealer did not sell junk guns was associated with a 68% reduction in the diversion of guns to criminals within a year of sale by the dealer and a 43% increase in guns diverted to criminals following sales by other dealers. The laws were associated with a 203% increase in the number of guns diverted to criminals within a year of sale by the gun store, which was the focus of this study. Policies which affect gun dealer accountability appeared to influence the diversion of guns to criminals.

  14. QUICKGUN: An algorithm for estimating the performance of two-stage light gas guns

    International Nuclear Information System (INIS)

    Milora, S.L.; Combs, S.K.; Gouge, M.J.; Kincaid, R.W.

    1990-09-01

    An approximate method is described for solving the equation of motion of a projectile accelerated by a two-stage light gas gun that uses high-pressure (<100-bar) gas from a storage reservoir to drive a piston to moderate speed (<400 m/s) for the purpose of compressing the low molecular weight propellant gas (hydrogen or helium) to high pressure (1000 to 10,000 bar) and temperature (1000 to 10,000 K). Zero-dimensional, adiabatic (isentropic) processes are used to describe the time dependence of the ideal gas thermodynamic properties of the storage reservoir and the first and second stages of the system. A one-dimensional model based on an approximate method of characteristics, or wave diagram analysis, for flow with friction (nonisentropic) is used to describe the nonsteady compressible flow processes in the launch tube. Linear approximations are used for the characteristic and fluid particle trajectories by averaging the values of the flow parameters at the breech and at the base of the projectile. An assumed functional form for the Mach number at the breech provides the necessary boundary condition. Results of the calculation are compared with data obtained from two-stage light gas gun experiments at Oak Ridge National Laboratory for solid deuterium and nylon projectiles with masses ranging from 10 to 35 mg and for projectile speeds between 1.6 and 4.5 km/s. The predicted and measured velocities generally agree to within 15%. 19 refs., 3 figs., 2 tabs

  15. Effects of Exposure to Gun Violence in Movies on Children's Interest in Real Guns.

    Science.gov (United States)

    Dillon, Kelly P; Bushman, Brad J

    2017-11-01

    More US children die by accidental gun use than children in other developed countries. One factor that can influence children's interest in guns is exposure to media containing guns. To test whether children who see a movie containing guns will handle a real gun longer and will pull the trigger more times than children who see the same movie not containing guns. One hundred four children aged 8 to 12 years recruited through advertisements were randomly assigned in pairs to watch a 20-minute PG-rated movie containing or not containing guns in a university laboratory. Children then played with toys and games in a room for 20 minutes while being video recorded. A cabinet in the room contained a real (disabled) gun with a sensor counting trigger pulls. Recordings were coded for the time spent holding the gun and in aggressive play. Data were collected from July 15, 2015, through January 1, 2016, and analyzed using generalized estimating equations (Tweedie log-link for time spent holding the gun; Poisson log-link for pulling the trigger). The 2 main outcomes were time spent holding the gun and the number of trigger pulls. Control variables included sex, age, trait aggressiveness, exposure to violent media, interest in guns, and number of guns at home. Among the 104 study participants (62 boys [59.6%] and 42 girls [40.4%]; mean (SD) age, 9.9 [1.5] years), the adjusted median number of trigger pulls among children who saw the movie containing guns was 2.8 (interquartile range [IQR], 0.2-2.8) compared with 0.01 (IQR, 0.01-0.2) among children who saw the movie not containing guns (adjusted odds ratio, 22.3; 95% CI, 6.0-83.4; P gun among children who saw a movie containing guns was 53.1 (IQR, 35.5-53.1) compared with 11.1 (IQR, 10.7-16.7) among children who saw the movie not containing guns (adjusted odds ratio, 3.0; 95% CI, 0.9-9.9; P = .07). Qualitative analyses on 4 pairs from each condition found that children who saw the movie containing guns also played more

  16. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    Science.gov (United States)

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  17. Gun buyback programs: a venue to eliminate unwanted guns in the community.

    Science.gov (United States)

    Violano, Pina; Driscoll, Cassandra; Chaudhary, Neil K; Schuster, Kevin M; Davis, Kimberly A; Borer, Esther; Winters, Jane K; Hirsh, Michael P

    2014-09-01

    The United States has a high rate of death due to firearms, and gun buyback programs may mitigate these high death rates. Understanding the demographics, motivation, and geographic region of participants may improve program efficacy. Three Injury Free Coalition for Kids gun buyback programs, in collaboration with the local police, were studied: Phoenix, Arizona; Worcester, Massachusetts; and New Haven, Connecticut. Participants were defined as those who relinquished a firearm. A self-administered, anonymous, paper survey elicited information from participants regarding demographic data, formal training on the use of the firearm, how the firearm was acquired, potential child access, knowledge of others injured by a firearm, whether the firearm was stored unlocked, factors motivating the surrender of the firearm, and other factors. Survey results were entered into a composite database and analyzed for differences in location, race, sex, and other factors. Participants (n = 301) were predominantly male (73.5%), white (80.9%), and older than 55 years (59.0%). They lived an average of 19.0 miles from the event by zip codes and had an average median household income of $65,731. More than half (54.5%) did not purchase the firearm, acquiring it through inheritance, gift, or random find. Most (74.8%) had previous firearms training and were relinquishing for safety reasons (68.3%). Those relinquishing firearms for safety reasons were less likely to have purchased the firearm (odds ratio [OR], 2.46, p gun lock (OR, 0.15; p gun-wielding criminal acts were burglarized from the home of legal gun owners that had failed to secure them properly. The gun buyback program is solely one prong of a multipronged approach in reducing firearm-based interpersonal violence. Additional research is necessary to determine effective methods to target individuals who would have the greatest impact on gun violence if they relinquished their weapons. Through the forging of relationships and

  18. Multivariate soil fertility relationships for predicting the environmental persistence of 2,4,6-trinitrotoluene (TNT) and 1,3,5-trinitro-1,3,5-tricyclohexane (RDX) among taxonomically distinct soils.

    Science.gov (United States)

    Katseanes, Chelsea K; Chappell, Mark A; Hopkins, Bryan G; Durham, Brian D; Price, Cynthia L; Porter, Beth E; Miller, Lesley F

    2017-12-01

    After nearly a century of use in numerous munition platforms, TNT and RDX contamination has turned up largely in the environment due to ammunition manufacturing or as part of releases from low-order detonations during training activities. Although the basic knowledge governing the environmental fate of TNT and RDX are known, accurate predictions of TNT and RDX persistence in soil remain elusive, particularly given the universal heterogeneity of pedomorphic soil types. In this work, we proposed overcoming this problem by considering the environmental persistence of these munition constituents (MC) as multivariate mathematical functions over a variety of taxonomically distinct soil types, instead of a single constant or parameter of a specific absolute value. To test this idea, we conducted experiments where the disappearance kinetics of TNT and RDX were measured over a >300 h period in taxonomically distinct soils. Classical fertility-based soil measurements were log-transformed, statistically decomposed, and correlated to TNT and RDX disappearance rates (k -TNT and k -RDX ) using multivariate dimension-reduction and correlation techniques. From these efforts, we generated multivariate linear functions for k parameters across different soil types based on a statistically reduced set of their chemical and physical properties: Calculations showed that the soil properties exhibited strong covariance, with a prominent latent structure emerging as the basis for relative comparisons of the samples in reduced space. Loadings describing TNT degradation were largely driven by properties associated with alkaline/calcareous soil characteristics, while the degradation of RDX was attributed to the soil organic matter content - reflective of an important soil fertility characteristic. In spite of the differing responses to the munitions, batch data suggested that the overall nutrient dynamics were consistent for each soil type, as well as readily distinguishable from the other

  19. God and Guns: Examining Religious Influences on Gun Control Attitudes in the United States

    Directory of Open Access Journals (Sweden)

    Stephen M. Merino

    2018-06-01

    Full Text Available Mass shootings in the United States have generated significant media coverage and public concern, invigorating debates over gun control. Media coverage and academic research on gun control attitudes and reactions to mass shootings have paid little attention to the role of religion. Recent research sheds light on the complex relationship between religion and guns, including higher rates of gun ownership and stronger opposition to gun control among white evangelical Protestants. Using nationally representative survey data, this study examines the relationship between religious identity, gun ownership, and support for a range of gun control policies, including proposed remedies for preventing mass shootings. Compared with individuals from other religious traditions, evangelical Protestants are most opposed to stricter gun control laws and enforcement, even with statistical controls for gun ownership and demographic characteristics. Rather, they favor individualistic solutions and putting more emphasis on religious values in their social surroundings. I discuss how these findings reflect the cultural tools evangelical Protestants use to construct their understandings of social problems, including gun violence, and the broader implications for gun policy in the United States.

  20. Performance of a carbon nanotube field emission electron gun

    Science.gov (United States)

    Getty, Stephanie A.; King, Todd T.; Bis, Rachael A.; Jones, Hollis H.; Herrero, Federico; Lynch, Bernard A.; Roman, Patrick; Mahaffy, Paul

    2007-04-01

    A cold cathode field emission electron gun (e-gun) based on a patterned carbon nanotube (CNT) film has been fabricated for use in a miniaturized reflectron time-of-flight mass spectrometer (RTOF MS), with future applications in other charged particle spectrometers, and performance of the CNT e-gun has been evaluated. A thermionic electron gun has also been fabricated and evaluated in parallel and its performance is used as a benchmark in the evaluation of our CNT e-gun. Implications for future improvements and integration into the RTOF MS are discussed.

  1. Plasma-gun fueling for tokamak reactors

    International Nuclear Information System (INIS)

    Ehst, D.A.

    1980-11-01

    In light of the uncertain extrapolation of gas puffing for reactor fueling and certain limitations to pellet injection, the snowplow plasma gun has been studied as a fueling device. Based on current understanding of gun and plasma behavior a design is proposed, and its performance is predicted in a tokamak reactor environment

  2. Guns and Violence. Current Controversies.

    Science.gov (United States)

    Kim, Henny H., Ed.

    This book focuses on gun violence and gun control, presenting both sides of arguments about firearms ownership and gun control. Each of five chapters poses a question about gun control and provides answers for both sides of the question. The following essays are included: (1) "Gun Violence Is Becoming an Epidemic" (Bob Herbert); (2) "Gun Violence…

  3. Integrated Data Collection Analysis (IDCA) Program — RDX Standard Data Sets

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Phillips, Jason J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms, Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-04

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, for a third and fourth time in the Proficiency Test and averaged with the analysis results from the first and second time. The results, from averaging all four sets (1, 2, 3 and 4) of data suggest a material to have slightly more impact sensitivity, more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity, compared to the results from Set 1, which was used previously as the values for the RDX standard in IDCA Analysis Reports.

  4. Mars Ascent Vehicle-Propellant Aging

    Science.gov (United States)

    Dankanich, John; Rousseau, Jeremy; Williams, Jacob

    2015-01-01

    This project is to develop and test a new propellant formulation specifically for the Mars Ascent Vehicle (MAV) for the robotic Mars Sample Return mission. The project was initiated under the Planetary Sciences Division In-Space Propulsion Technology (ISPT) program and is continuing under the Mars Exploration Program. The two-stage, solid motor-based MAV has been the leading MAV solution for more than a decade. Additional studies show promise for alternative technologies including hybrid and bipropellant options, but the solid motor design has significant propellant density advantages well suited for physical constraints imposed while using the SkyCrane descent stage. The solid motor concept has lower specific impulse (Isp) than alternatives, but if the first stage and payload remain sufficiently small, the two-stage solid MAV represents a potential low risk approach to meet the mission needs. As the need date for the MAV slips, opportunities exist to advance technology with high on-ramp potential. The baseline propellant for the MAV is currently the carboxyl terminated polybutadiene (CTPB) based formulation TP-H-3062 due to its advantageous low temperature mechanical properties and flight heritage. However, the flight heritage is limited and outside the environments, the MAV must endure. The ISPT program competed a propellant formulation project with industry and selected ATK to develop a new propellant formulation specifically for the MAV application. Working with ATK, a large number of propellant formulations were assessed to either increase performance of a CTPB propellant or improve the low temperature mechanical properties of a hydroxyl terminated polybutadiene (HTPB) propellant. Both propellants demonstrated potential to increase performance over heritage options, but an HTPB propellant formulation, TP-H-3544, was selected for production and testing. The test plan includes propellant aging first at high vacuum conditions, representative of the Mars transit

  5. Preliminary characterization of propellants based on p(GA/BAMO) and pAMMO binders

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Ugo; Polacco, Giovanni [Department of Chemical Engineering, University of Pisa (Italy); Keicher, Thomas [Fraunhofer-Institut fuer Chemische Technologie (ICT), Pfinztal (Germany); Massimi, Roberto [AVIO S.p.A., Roma (Italy)

    2009-10-15

    In previous papers, the synthesis and characterization of OH-terminated glycidyl azide-r-(3,3-bis(azidomethyl)oxetane) copolymers (GA/BAMO) and poly-3-azidomethyl-3-methyl oxetane (pAMMO) by azidation of their respective polymeric substrates were described. The main objective was the preparation of amorphous azido-polymers, as substitutes of hydroxy-terminated polybutadiene (HTPB) in new formulations of energetic propellants. Here, the subsequent characterization of both the binders is presented. First of all, several isocyanates were checked in order to optimize the curing reaction, and then two small-scale formulations of a propellant, based on aluminium and ammonium perchlorate, were prepared and characterized. Finally, the mechanical properties and burning rate were compared to those of a similar propellant based on HTPB as binder. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  6. Gun control saves lives

    African Journals Online (AJOL)

    gun control legislation. One study estimated that more than 4 500 lives were saved across five SA cities from 2001 to 2005.[5] Pro-gun interest groups seeking to promote gun ownership and diffusion have attacked these findings, suggesting that stricter gun control was only enacted in 2004 following the publication of ...

  7. Gun Sales. Firearm Facts.

    Science.gov (United States)

    Duker, Laurie, Ed.

    Minimal federal regulations on firearm sales have facilitated the proliferation of guns, gun owners, and gun dealers in the United States. This fact sheet offers data on the growing number of firearm dealers, the relative ease of obtaining and keeping a license to sell guns from the Federal Bureau of Alcohol, Tobacco, and Firearms, the lack of…

  8. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  9. LX-04 VIOLENCE MEASUREMENTS- STEVEN TESTS IMPACTED BY PROJECTILES SHOT FROM A HOWITZER GUN

    International Nuclear Information System (INIS)

    Chidester, S K; Vandersall, K S; Switzer, L L; Tarver, C M

    2005-01-01

    Characterization of the reaction violence of LX-04 explosive (85% HMX and 15% Viton A by weight) was obtained from Steven Impact Tests performed above the reaction initiation threshold. A 155 mm Howitzer propellant driven gas gun was used to accelerate the Steven Test projectiles in the range of approximately 170-300 m/s to react (ignite) the LX-04 explosive. Blast overpressure gauges, acoustic microphones, and high-speed photography characterized the level of high explosive reaction violence. A detonation in this velocity range was not observed and when comparing these results (and the Susan test results) with that of other HMX based explosives, LX-04 has a more gradual reaction violence slope as the impact velocity increases. The high binder content (15%) of the LX-04 explosive is believed to be the key factor to the lower level of violence

  10. GUN4-Porphyrin Complexes Bind the ChlH/GUN5 Subunit of Mg-Chelatase and Promote Chlorophyll Biosynthesis in Arabidopsis[W

    Science.gov (United States)

    Adhikari, Neil D.; Froehlich, John E.; Strand, Deserah D.; Buck, Stephanie M.; Kramer, David M.; Larkin, Robert M.

    2011-01-01

    The GENOMES UNCOUPLED4 (GUN4) protein stimulates chlorophyll biosynthesis by activating Mg-chelatase, the enzyme that commits protoporphyrin IX to chlorophyll biosynthesis. This stimulation depends on GUN4 binding the ChlH subunit of Mg-chelatase and the porphyrin substrate and product of Mg-chelatase. After binding porphyrins, GUN4 associates more stably with chloroplast membranes and was proposed to promote interactions between ChlH and chloroplast membranes—the site of Mg-chelatase activity. GUN4 was also proposed to attenuate the production of reactive oxygen species (ROS) by binding and shielding light-exposed porphyrins from collisions with O2. To test these proposals, we first engineered Arabidopsis thaliana plants that express only porphyrin binding–deficient forms of GUN4. Using these transgenic plants and particular mutants, we found that the porphyrin binding activity of GUN4 and Mg-chelatase contribute to the accumulation of chlorophyll, GUN4, and Mg-chelatase subunits. Also, we found that the porphyrin binding activity of GUN4 and Mg-chelatase affect the associations of GUN4 and ChlH with chloroplast membranes and have various effects on the expression of ROS-inducible genes. Based on our findings, we conclude that ChlH and GUN4 use distinct mechanisms to associate with chloroplast membranes and that mutant alleles of GUN4 and Mg-chelatase genes cause sensitivity to intense light by a mechanism that is potentially complex. PMID:21467578

  11. PIV-based load determination in aircraft propellers

    OpenAIRE

    Ragni, D.

    2012-01-01

    The thesis describes the application of particle image velocimetry (PIV) to study the aerodynamic loads of airfoils and aircraft propellers. The experimental work focuses on the development of a measurement procedure to infer the pressure of the flow field from the velocity distribution obtained by PIV velocimetry. The technique offers important advantages in aircraft propellers, since the loads can be locally inspected without the need to install pressure sensors and momentum balances in rot...

  12. Racism, gun ownership and gun control: biased attitudes in US whites may influence policy decisions.

    Science.gov (United States)

    O'Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites' paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions.

  13. Mechanical and chemical responses of low-velocity impacted RDX and HMX explosive powders

    Science.gov (United States)

    Wu, Yanqing; Guo, Hongfu; Huang, Fenglei; Bao, Xiaowei; Explosion; damage Team

    2017-06-01

    The experimental analyses of mechanical and chemical responses of RDX and HMX particles were performed based on the optimized drop-weight experimental system equipped with the High-Speed Camera (HSC). It has been found that Jetting phenomenon observed by HSC is the result of the energy released by gaseous products, which push the pulverized or melted explosives to splash radially. Jetting is the only and the most obvious difference between reactive and inert particles prior to combustion so that jetting can be regarded as the sign of ignition. Area expansion velocity, jetting velocity, and flame propagation velocity have been estimated via image processing, making it possible to characterize mechanical deformation and violence of reaction of each stage. Hot-spots coalescence promotes flame propagation whose velocity reflects the violence of deflagration reaction. Jetting appearance time can be used to determine time-to-ignition more accurately than other ways. For RDX, molten phase plays an important role to the formation of the hot-spots. Multiple particles experienced more severe burning reactions than an individual particle. China National Nature Science Foundation (11572045), ``Science Challenging Program'' (JCKY2016212A501),opening fund from Safety ammunition research and Development Center (RMC2015B03).

  14. Biotransformation of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by a prospective consortium and its most effective isolate Serratia marcescens

    Energy Technology Data Exchange (ETDEWEB)

    Young, D.M.; Ogden, K.L. [Univ. of Arizona, Tucson, AZ (United States). Dept. of Chemical and Environmental Engineering; Unkefer, P.J. [Los Alamos National Lab., NM (United States). Chemical Science and Technology Div.

    1997-03-05

    The biotransformation of hexahydro-1,3,5-trinitro-1,3,5 triazine (RDX) has been observed in liquid culture by a consortium of bacteria found in horse manure. Five types of bacteria were found to predominate in the consortium and were isolated. The most effective of these isolates at transforming RDX was Serratia marcescens. The biotransformation of RDX by all of these bacteria was found to occur only in the anoxic stationary phase. The process of bacterial growth and RDX biotransformation was quantified for the purpose of developing a predictive type model. Cell growth was assumed to follow Monod kinetics. All of the aerobic and anoxid growth parameters were determined: {mu}{sub max}, K{sub s}, and Y{sub x/s}. RDX was found to competitively inhibit cell growth in both atmospheres. Degradation of RDX by Serratia marcescens was found to proceed through the stepwise reduction of the three nitro groups to nitroso groups. Each of these reductions was found to be first order in both component and cell concentrations. The degradation rate constant for the first step in this reduction process by the consortium was 0.022 L/g cells {center_dot} h compared to 0.033 L/g cells {center_dot} h for the most efficient isolate.

  15. Design of the BEPCII electron gun system

    International Nuclear Information System (INIS)

    Liu Bo; Gu Mengping; Chi Yunlong

    2006-01-01

    BEPCII upgrading project needs a new high current electron gun. The design stage such as physical design, mechanical design and control system design of this new electron gun is described. The emission current is designed to be higher than 10 A for the pulse width of 1 ns with repetition rate of 50 Hz. The gun will operate with a pulsed high voltage power supply which can provide up to 200 kV high voltage. Computer simulations and optimizations have been carried out in the design stage, including the gun geometry and beam transport. EGUN and DGUN codes are used to simulate the gun geometry, and the results show that the perveance is about 0.22 μA·V -3/2 , and the emittance at gun exit is about 16 π·mm·mrad. PARMELA code shows that the electron beam can be easily transported to the end of the first accelerating tube with a capture efficiency of 67% and root mean square emittance of 25 mm·mrad. New scheme of the gun control system based on EPICS is also presented. Two-bunch operation mode and 2.5 μs long pulse operation mode are available in the control system. (authors)

  16. A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

    Science.gov (United States)

    Kumar, N.; Lamba, R. P.; Hossain, A. M.; Pal, U. N.; Phelps, A. D. R.; Prakash, R.

    2017-11-01

    The experimental study of a tapered, multi-gap, multi-aperture pseudospark-sourced electron gun based X-band plasma assisted slow wave oscillator is presented. The designed electron gun is based on the pseudospark discharge concept and has been used to generate a high current density and high energy electron beam simultaneously. The distribution of apertures has been arranged such that the field penetration potency inside the backspace of the hollow-cathode is different while passing through the tapered gap region. This leads to non-concurrent ignition of the discharge through all the channels which is, in general, quite challenging in the case of multi-aperture plasma cathode electron gun geometries. Multiple and successive hollow cathode phases are reported from this electron gun geometry, which have been confirmed using simulations. This geometry also has led to the achievement of ˜71% fill factor inside the slow wave oscillator for an electron beam of energy of 20 keV and a beam current density in the range of 115-190 A/cm2 at a working argon gas pressure of 18 Pa. The oscillator has generated broadband microwave output in the frequency range of 10-11.7 GHz with a peak power of ˜10 kW for ˜50 ns.

  17. Access to a Loaded Gun Without Adult Permission and School-Based Bullying.

    Science.gov (United States)

    Simckes, Maayan S; Simonetti, Joseph A; Moreno, Megan A; Rivara, Frederick P; Oudekerk, Barbara A; Rowhani-Rahbar, Ali

    2017-09-01

    Gun access and bullying are risk factors for sustaining or perpetrating violence among adolescents. Our knowledge of gun access among bullied students is limited. We used data on students, aged 12-18 years, from the 2011 and 2013 School Crime Supplement to the National Crime Victimization Survey to assess the association between self-reported bullying victimization (traditional and cyber) and access to a loaded gun without adult permission. Prevalence ratios (PRs) and confidence intervals (CIs) were obtained from multivariable Poisson regression using the Taylor series after controlling for student age, sex, family income, public/private school, and race. Of 10,704 participants, 4.2% (95% CI: 3.8%-4.6%) reported gun access. Compared with nonbullied students, those who reported traditional bullying (PR = 2.2; 95% CI: 1.7-2.4), cyberbullying (PR = 2.8; 95% CI: 1.6-4.9), and both (PR = 5.9; 95% CI: 4.6-7.7) were more likely to also report gun access. Adolescents who experience bullying, particularly those who report both traditional bullying and cyberbullying, are more likely to report access to a loaded gun without adult permission. These findings highlight the importance of developing interventions focused on these modifiable risk factors for preventing self-directed or interpersonal violence among youth. Copyright © 2017 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  18. Racism, gun ownership and gun control: biased attitudes in US whites may influence policy decisions.

    Directory of Open Access Journals (Sweden)

    Kerry O'Brien

    Full Text Available OBJECTIVE: Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty. This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. METHOD: The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. RESULTS: After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58 was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46, which likely represents self-interest in retaining property (guns. CONCLUSIONS: Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites' paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions.

  19. Racism, Gun Ownership and Gun Control: Biased Attitudes in US Whites May Influence Policy Decisions

    Science.gov (United States)

    O’Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Objective Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. Method The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. Results After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Conclusions Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites’ paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions. PMID:24204867

  20. Gun power source for electron gun of 3 MeV DC accelerator

    International Nuclear Information System (INIS)

    Dewangan, S.; Sharma, D.K.; Nanu, K.

    2011-01-01

    In DC electron beam accelerator electron gun is situated at high voltage terminal which requires constant power irrespective of beam energy. Floating power source is required for gun. This paper describes the scheme of static gun power source derived from parallel coupled voltage multiplier column. (author)

  1. Acceleration of solid pellets using a plasma gun

    International Nuclear Information System (INIS)

    Buller, T.L.; Turnbull, R.J.; Kim, K.

    1979-01-01

    The use of solid pellets of hydrogen isotopes to refuel thermonuclear fusion reactors based on the tokamak configuration will require that the pellets be accelerated to high velocities. One possible method of acceleration is to interact a fast plasma from a plasma gun with the pellets. In this paper preliminary results are given on the acceleration of solid pellets with a plasma gun. The plasma-gun requirements for successful acceleration to high velocities are discussed

  2. Quadcopter thrust optimization with ducted-propeller

    Directory of Open Access Journals (Sweden)

    Kuantama Endrowednes

    2017-01-01

    Full Text Available In relation to quadcopter body frame model, propeller can be categorized into propeller with ducted and without ducted. This study present differences between those two using CFD (Computational Fluid Dynamics method. Both categories utilize two blade-propeller with diameter of 406 (mm. Propeller rotation generates acceleration per time unit on the volume of air. Based on the behavior of generated air velocity, ducted propeller can be modeled into three versions. The generated thrust and performance on each model were calculated to determine the best model. The use of ducted propeller increases the total weight of quadcopter and also total thrust. The influence of this modeling were analyzed in detail with variation of angular velocity propeller from 1000 (rpm to 9000 (rpm. Besides the distance between propeller tip and ducted barrier, the size of ducted is also an important part in thrust optimization and total weight minimization of quadcopter.

  3. Development of a novel disturbance observer based fractional order PD controller for a gun control system.

    Science.gov (United States)

    Gao, Qiang; Zheng, Liang; Chen, Jilin; Wang, Li; Hou, Yuanlong

    2014-01-01

    Motion control of gun barrels is an ongoing topic for the development of gun control equipment (GCE) with excellent performances. In this paper, a novel disturbance observer (DOB) based fractional order PD (FOPD) control strategy is proposed for the GCE. By adopting the DOB, the control system behaves as if it were the nominal closed-loop system in the absence of disturbances and uncertainties. The optimal control parameters of the FOPD are determined from the loop-shaping perspective, and the Q-filter of the DOB is deliberately designed with consideration of system robustness. The linear frame of the proposed control system will enable the analysis process more convenient. The disturbance rejection properties and the tracking performances of the control system are investigated by both numerical and experimental tests, the results demonstrate that the proposed DOB based FOPD control system is of more robustness, and it is much more suitable for the gun control system with strong nonlinearity and disturbance.

  4. Triphenylamine - a 'new' stabilizer for nitrocellulose based propellants. Pt. 1: chemical stability studies

    Energy Technology Data Exchange (ETDEWEB)

    Wilker, Stephan; Heeb, Gerhard [WIWEB ASt Heimerzheim, Grosses Cent, 53913 Swisttal (Germany); Vogelsanger, Beat [Nitrochemie Wimmis AG, Niesenstr. 44, 3752 Wimmis (Switzerland); Petrzilek, Jan; Skladal, Jan [Explosia a.s. - Research Institute of Industrial Chemistry (VUPCH), 532 17 Pardubice (Czech Republic)

    2007-04-15

    Triphenylamine (TPA) was used for the first time in France in 1937 as a stabilizer for propellants. The stability of those samples was described as 'good'. Around 1950 an American group produced TPA stabilized propellants and investigated the decomposition mechanism. Apart from one single experiment in the 1970s no further attempts were made to take TPA as a stabilizer for propellants. With the background of an increasingly critical discussion about nitrosamines in propellants and their declaration of being carcinogenic, TPA revealed a renaissance since the year 2000. To achieve the goal of nitrosamine free propellants several TPA stabilized propellants were produced. Their processability, stability and ballistic properties were investigated. This publication summarizes the most important results of stability tests on more than 30 different TPA stabilized propellants including the decomposition mechanism, the synthesis of the consecutive products and their stabilizing properties. In addition, the internal compatibility of TPA with the most important propellant ingredients is discussed and its relative decomposition rate is compared with that of other stabilizers. In summary TPA is a suitable stabilizer for propellants. It has nevertheless two disadvantages. It is relatively rapidly consumed in double base formulations (which makes it difficult to pass the criteria of AOP-48, Ed. 2) and the stabilizing activity of the two major consecutive products 4-NO{sub 2}-TPA and especially 4,4{sup '}-di-NO{sub 2}-TPA is low. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  5. Lon protease affects the RdxA nitroreductase activity and metronidazole susceptibility in Helicobacter pylori.

    Science.gov (United States)

    Tu, I-Fan; Liao, Jiahn-Haur; Yang, Feng-Ling; Lin, Nien-Tsung; Chan, Hong-Lin; Wu, Shih-Hsiung

    2014-10-01

    The lon gene of Helicobacter pylori strains is constitutively expressed during growth. However, virtually nothing is understood concerning the role of Lon in H. pylori. This study examined the function and physiological role of Lon in H. pylori (HpLon) using a trapping approach to identify putative Lon binding partners in the bacterium. Protease-deficient Lon was expressed and served as the bait in trapping approach to capture the interacting partners in H. pylori. The antibiotic susceptibility of wild-type and lon derivative mutants was determined by the E test trips and the disc diffusion assay. The effect of HpLon on RdxA activity was detected the change in NADPH oxidation and metronidazole reduction by spectrophotometer. Lon in Helicobacter pylori (HpLon) interacting partners are mostly associated with metronidazole activation. lon mutant presents more susceptible to metronidazole than that of the wild type, and this phenotype is recovered by complementation of the wild-type Lon. We found that the ATPases associated with a variety of cellular activities (AAA(+) ) module of HpLon causes a decrease in both NADPH oxidase and Mtz reductase activity in RdxA, a major Mtz-activating enzyme in H. pylori. Metronidazole resistance of H. pylori causes the serious medical problem worldwide. In this study, HpLon is involved in metronidazole susceptibility among H. pylori strains. We provide the evidence that HpLon alters RdxA activity in vitro. The decrease in metronidazole activation caused by HpLon is possibly prior to accumulate mutation in rdxA gene before the metronidazole-resistant strains to be occurred. © 2014 John Wiley & Sons Ltd.

  6. Polarizability of acetanilide and RDX in the crystal: effect of molecular geometry

    Science.gov (United States)

    Tsiaousis, D.; Munn, R. W.; Smith, P. J.; Popelier, P. L. A.

    2004-10-01

    Density-functional theory with the B3LYP functional at the 6-311++G** level is used to calculate the dipole moment and the static polarizability for acetanilide and 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX) in their in-crystal structures. For acetanilide the dipole moment is 2{1}/{2}% larger than for the gas-phase structure and for RDX (where there is a gross geometry change) it is 15% larger. The polarizability for the in-crystal structure is smaller than for the gas-phase structure by 3% for both species, whereas the in-crystal effective optical polarizability is larger than the gas-phase static polarizability for both crystals. Hence, effects in addition to the molecular geometry change in the crystal must be considered in order to interpret the effective polarizability completely.

  7. A photocathode rf gun design for a mm-wave linac-based FEL

    Energy Technology Data Exchange (ETDEWEB)

    Nassiri, A.; Berenc, T,; Foster, J.; Waldschmidt, G.; Zhou, J.

    1995-07-01

    In recent years, advances in the rf gun technology have made it possible to produce small beam emittances suitable for short period microundulators which take advantage of the low emittance beam to reduce the wavelength of FELs. At the Advanced Photon Source, we are studying the design of a compact 50-MeV superconducting mm-wave linac-based FEL for the production of short wavelengths ({approximately}300 nm) to carry out FEL demonstration experiments. The electron source considered for the linac is a 30- GHz, 3 1/2-cell {pi}-mode photocathode rf gun. For cold model rf measurements a 15-GHz prototype structure was fabricated. Here we report on the design, numerical modelling and the initial cold-model rf measurement results on the 15-GHz prototype structure.

  8. A photocathode rf gun design for a mm-wave linac-based FEL

    International Nuclear Information System (INIS)

    Nassiri, A.; Berenc, T.; Foster, J.; Waldschmidt, G.; Zhou, J.

    1995-01-01

    In recent years, advances in the rf gun technology have made it possible to produce small beam emittances suitable for short period microundulators which take advantage of the low emittance beam to reduce the wavelength of FELs. At the Advanced Photon Source, we are studying the design of a compact 50-MeV superconducting mm-wave linac-based FEL for the production of short wavelengths (∼300 nm) to carry out FEL demonstration experiments. The electron source considered for the linac is a 30- GHz, 3 1/2-cell π-mode photocathode rf gun. For cold model rf measurements a 15-GHz prototype structure was fabricated. Here we report on the design, numerical modelling and the initial cold-model rf measurement results on the 15-GHz prototype structure

  9. Aminoxyl (nitroxyl) radicals in the early decomposition of the nitramine RDX.

    Science.gov (United States)

    Irikura, Karl K

    2013-03-14

    The explosive nitramine RDX (1,3,5-trinitrohexahydro-s-triazine) is thought to decompose largely by homolytic N-N bond cleavage, among other possible initiation reactions. Density-functional theory (DFT) calculations indicate that the resulting secondary aminyl (R2N·) radical can abstract an oxygen atom from NO2 or from a neighboring nitramine molecule, producing an aminoxyl (R2NO·) radical. Persistent aminoxyl radicals have been detected in electron-spin resonance (ESR) experiments and are consistent with autocatalytic "red oils" reported in the experimental literature. When the O-atom donor is a nitramine, a nitrosamine is formed along with the aminoxyl radical. Reactions of aminoxyl radicals can lead readily to the "oxy-s-triazine" product (as the s-triazine N-oxide) observed mass-spectrometrically by Behrens and co-workers. In addition to forming aminoxyl radicals, the initial aminyl radical can catalyze loss of HONO from RDX.

  10. Carbon plasma gun

    International Nuclear Information System (INIS)

    Mendel, C.W. Jr.; Zagar, D.M.; Mills, G.S.; Humphries, S. Jr.; Goldstein, S.A.

    1980-01-01

    A family of plasma guns supplying highly ionized carbon plasma is described. The guns are simple and inexpensive to construct and are pulsed by small capacitor banks of a few hundred joules. The output consists of 10 17 --10 18 multiply ionized carbon ions traveling at about 10 7 cm/s. Neutral output is very low and arrives well after the ionized carbon. The guns and pulsers are very reliable

  11. Study of nano-nitramine explosives: preparation, sensitivity and application

    Directory of Open Access Journals (Sweden)

    Jie Liu

    2014-06-01

    Full Text Available Nano-nitramine explosives (RDX, HMX, CL-20 are produced on a bi-directional grinding mill. The scanning electron microscope (SEM observations show that the prepared particles are semi-spherical, and the narrow size distributions are characterized using the laser particle size analyzer. Compared with the micron-sized samples, the nano-products show obvious decrease in friction and impact sensitivities. In the case of shock sensitivities, nano-products have lower values by 59.9% (RDX, 56.4% (HMX, and 58.1% (CL-20, respectively. When nano-RDX and nano-HMX are used in plastic bonded explosives (PBX as alternative materials of micron-sized particles, their shock sensitivities are significantly decreased by 24.5% (RDX and 22.9% (HMX, and their detonation velocities are increased by about 1.7%. Therefore, it is expected to promote the application of nano-nitramine explosives in PBXs and composite modified double-based propellants (CMDBs so that some of their properties would be improved.

  12. Gun bore flaw image matching based on improved SIFT descriptor

    Science.gov (United States)

    Zeng, Luan; Xiong, Wei; Zhai, You

    2013-01-01

    In order to increase the operation speed and matching ability of SIFT algorithm, the SIFT descriptor and matching strategy are improved. First, a method of constructing feature descriptor based on sector area is proposed. By computing the gradients histogram of location bins which are parted into 6 sector areas, a descriptor with 48 dimensions is constituted. It can reduce the dimension of feature vector and decrease the complexity of structuring descriptor. Second, it introduce a strategy that partitions the circular region into 6 identical sector areas starting from the dominate orientation. Consequently, the computational complexity is reduced due to cancellation of rotation operation for the area. The experimental results indicate that comparing with the OpenCV SIFT arithmetic, the average matching speed of the new method increase by about 55.86%. The matching veracity can be increased even under some variation of view point, illumination, rotation, scale and out of focus. The new method got satisfied results in gun bore flaw image matching. Keywords: Metrology, Flaw image matching, Gun bore, Feature descriptor

  13. Is it a dangerous world out there? The motivational bases of American gun ownership

    NARCIS (Netherlands)

    Stroebe, Wolfgang; Leander, N. Pontus; Kruglanski, Arie W.

    2017-01-01

    Americans are the world’s best armed citizens and public polling suggests protection/self-defense is their main reason for gun ownership. However, there is virtually no psychological research on gun ownership. The present article develops the first psychological process model of defensive gun

  14. Carbon Nanotube Electron Gun

    Science.gov (United States)

    Nguyen, Cattien V. (Inventor); Ribaya, Bryan P. (Inventor)

    2013-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  15. International Space Station-Based Electromagnetic Launcher for Space Science Payloads

    Science.gov (United States)

    Jones, Ross M.

    2013-01-01

    A method was developed of lowering the cost of planetary exploration missions by using an electromagnetic propulsion/launcher, rather than a chemical-fueled rocket for propulsion. An electromagnetic launcher (EML) based at the International Space Station (ISS) would be used to launch small science payloads to the Moon and near Earth asteroids (NEAs) for the science and exploration missions. An ISS-based electromagnetic launcher could also inject science payloads into orbits around the Earth and perhaps to Mars. The EML would replace rocket technology for certain missions. The EML is a high-energy system that uses electricity rather than propellant to accelerate payloads to high velocities. The most common type of EML is the rail gun. Other types are possible, e.g., a coil gun, also known as a Gauss gun or mass driver. The EML could also "drop" science payloads into the Earth's upper

  16. Patterns of gun deaths across US counties 1999-2013.

    Science.gov (United States)

    Kalesan, Bindu; Galea, Sandro

    2017-05-01

    We examined the socio-demographic distribution of gun deaths across 3143 counties in 50 United States' states to understand the spatial patterns and correlates of high and low gun deaths. We used aggregate counts of gun deaths and population in all counties from 1999 to 2013 from the Centers for Disease Control and Prevention's Wide-ranging Online Data for Epidemiologic Research (WONDER). We characterized four levels of gun violence, as distinct levels of gun death rates of relatively safe, unsafe, violent, and extremely violent counties, based on quartiles of 15-year county-specific gun death rates per 100,000 and used negative binomial regression models allowing clustering by state to calculate incidence rate ratios and 95% confidence intervals (95% CIs). Most states had at least one violent or extremely violent county. Extremely violent gun counties were mostly rural, poor, predominantly minority, had high unemployment rate and homicide rate. Overall, homicide rate was significantly associated with gun deaths (incidence rate ratios = 1.08, 95% CI = 1.06-1.09). In relatively safe counties, this risk was 1.09 (95% CI = 1.05-1.13) and in extremely violent gun counties was 1.03 (95% CI = 1.03-1.04). There are broad differences in gun death rates across the United States representing different levels of gun death rates in each state with distinct socio-demographic profiles. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. An Evaluation of the Environmental Fate and Behavior of Munitions Material (TNT, RDX) in Soil and Plant Systems. Environmental Fate and Behavior of RDX

    Science.gov (United States)

    1990-08-01

    2.2 2.2 SOIL CHARACTERIZATION AND SAMPLING ............................................. 2.7 2.3 PLANT CULTIVATION ...cycle. 2.3 Plant Cultivation and Samoling The chemical fate of RDX in plants was evaluated using bush beans K (Phaseolus vulgaris), wheat (Triticum...particularly in light of the high tissue concentrations observed, may be important from the standpoint of food-chain transfer and ecotoxicology

  18. Is It a Dangerous World Out There? The Motivational Bases of American Gun Ownership.

    Science.gov (United States)

    Stroebe, Wolfgang; Leander, N Pontus; Kruglanski, Arie W

    2017-08-01

    Americans are the world's best armed citizens and public polling suggests protection/self-defense is their main reason for gun ownership. However, there is virtually no psychological research on gun ownership. The present article develops the first psychological process model of defensive gun ownership-specifically, a two-component model that considers both the antecedents and consequences of owning a gun for protection/self-defense. We demonstrate that different levels of threat construal-the specific perceived threat of assault and a diffuse threat of a dangerous world-independently predict handgun ownership; we also show how utility judgments can explain the motivated reasoning that drives beliefs about gun rights. We tested our model in two independent samples of gun owners (total N = 899), from just before and after the Orlando mass shooting. This study illustrates how social-cognitive theories can help explain what motivates Americans to own handguns and advocate for broad rights to carry and use them.

  19. Gun Violence Restraining Orders: Alternative or Adjunct to Mental Health-Based Restrictions on Firearms?

    Science.gov (United States)

    Frattaroli, Shannon; McGinty, Emma E; Barnhorst, Amy; Greenberg, Sheldon

    2015-06-01

    The gun violence restraining order (GVRO) is a new tool for preventing gun violence. Unlike traditional approaches to prohibiting gun purchase and possession, which rely on a high threshold (adjudication by criminal justice or mental health systems) before intervening, the GVRO allows family members and intimate partners who observe a relative's dangerous behavior and believe it may be a precursor to violence to request a GVRO through the civil justice system. Once issued by the court, a GVRO authorizes law enforcement to remove any guns in the respondent's possession and prohibits the respondent from purchasing new guns. In September 2014, California's governor signed AB1014 into law, making California the first U.S. state to enact a GVRO law. This article describes the GVRO and the rationale behind the concept, considers case examples to assess the potential impact of the GVRO as a strategy for preventing gun violence, and reviews the content of the California law. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Intelligent Control of Welding Gun Pose for Pipeline Welding Robot Based on Improved Radial Basis Function Network and Expert System

    Directory of Open Access Journals (Sweden)

    Jingwen Tian

    2013-02-01

    Full Text Available Since the control system of the welding gun pose in whole-position welding is complicated and nonlinear, an intelligent control system of welding gun pose for a pipeline welding robot based on an improved radial basis function neural network (IRBFNN and expert system (ES is presented in this paper. The structure of the IRBFNN is constructed and the improved genetic algorithm is adopted to optimize the network structure. This control system makes full use of the characteristics of the IRBFNN and the ES. The ADXRS300 micro-mechanical gyro is used as the welding gun position sensor in this system. When the welding gun position is obtained, an appropriate pitch angle can be obtained through expert knowledge and the numeric reasoning capacity of the IRBFNN. ARM is used as the controller to drive the welding gun pitch angle step motor in order to adjust the pitch angle of the welding gun in real-time. The experiment results show that the intelligent control system of the welding gun pose using the IRBFNN and expert system is feasible and it enhances the welding quality. This system has wide prospects for application.

  1. Sanoli Gun

    Indian Academy of Sciences (India)

    Home; Journals; Proceedings – Mathematical Sciences. Sanoli Gun. Articles written in Proceedings – Mathematical Sciences. Volume 119 Issue 3 June 2009 pp 275-281. Remarks on some Zero-Sum Theorems · S D Adhikari Sanoli Gun Purusottam Rath · More Details Abstract Fulltext PDF. In the present paper, we give a ...

  2. Beam emittance measurement from CERN thermionic guns

    International Nuclear Information System (INIS)

    Kester, O.; Rao, R.; Rinolfi, L.

    1992-01-01

    In the LEP Injector Linacs (LIL) a thermionic gun provides electron beams with different peak intensities at an energy of 80 keV. The beam emittances were estimated from the EGUN programme. Since the gun is of triode type, the main contribution to the emittance comes from the grid. The simulation programme does not model the real geometry by assuming a cylindrical symmetry, while the grid does not have such symmetry. A Gun Test Facility (GTF), allowing emittance measurements, based on the 3-gradients-method was installed. The experimental results are presented. (author) 6 refs.; 6 figs

  3. Large Bore Powder Gun Qualification (U)

    Energy Technology Data Exchange (ETDEWEB)

    Rabern, Donald A. [Los Alamos National Laboratory; Valdiviez, Robert [Los Alamos National Laboratory

    2012-04-02

    A Large Bore Powder Gun (LBPG) is being designed to enable experimentalists to characterize material behavior outside the capabilities of the NNSS JASPER and LANL TA-55 PF-4 guns. The combination of these three guns will create a capability to conduct impact experiments over a wide range of pressures and shock profiles. The Large Bore Powder Gun will be fielded at the Nevada National Security Site (NNSS) U1a Complex. The Complex is nearly 1000 ft below ground with dedicated drifts for testing, instrumentation, and post-shot entombment. To ensure the reliability, safety, and performance of the LBPG, a qualification plan has been established and documented here. Requirements for the LBPG have been established and documented in WE-14-TR-0065 U A, Large Bore Powder Gun Customer Requirements. The document includes the requirements for the physics experiments, the gun and confinement systems, and operations at NNSS. A detailed description of the requirements is established in that document and is referred to and quoted throughout this document. Two Gun and Confinement Systems will be fielded. The Prototype Gun will be used primarily to characterize the gun and confinement performance and be the primary platform for qualification actions. This gun will also be used to investigate and qualify target and diagnostic modifications through the life of the program (U1a.104 Drift). An identical gun, the Physics Gun, will be fielded for confirmatory and Pu experiments (U1a.102D Drift). Both guns will be qualified for operation. The Gun and Confinement System design will be qualified through analysis, inspection, and testing using the Prototype Gun for the majority of process. The Physics Gun will be qualified through inspection and a limited number of qualification tests to ensure performance and behavior equivalent to the Prototype gun. Figure 1.1 shows the partial configuration of U1a and the locations of the Prototype and Physics Gun/Confinement Systems.

  4. Development of a novel hydroxyl ammonium nitrate based liquid propellant for air-independent propulsion

    Science.gov (United States)

    Fontaine, Joseph Henry

    The focus of this dissertation is the development of an Unmanned Undersea Vehicle (UUV) liquid propellant employing Hydroxyl Ammonium Nitrate (HAN) as the oxidizer. Hydroxyl Ammonium Nitrate is a highly acidic aqueous based liquid oxidizer. Therefore, in order to achieve efficient combustion of a propellant using this oxidizer, the fuel must be highly water soluble and compatible with the oxidizer to prevent a premature ignition prior to being heated within the combustion chamber. An extensive search of the fuel to be used with this oxidizer was conducted. Propylene glycol was chosen as the fuel for this propellant, and the propellant given the name RF-402. The propellant development process will first evaluate the propellants thermal stability and kinetic parameters using a Differential Scanning Calorimeter (DSC). The purpose of the thermal stability analysis is to determine the temperature at which the propellant decomposition begins for the future safe handling of the propellant and the optimization of the combustion chamber. Additionally, the thermogram results will provide information regarding any undesirable endotherms prior to the decomposition and whether or not the decomposition process is a multi-step process. The Arrhenius type kinetic parameters will be determined using the ASTM method for thermally unstable materials. The activation energy and pre-exponential factor of the propellant will be determined by evaluating the decomposition peak temperature over a temperature scan rate ranging from 1°C per minute to 10°C per minute. The kinetic parameters of the propellant will be compared to those of 81 wt% HAN to determine if the HAN decomposition is controlling the overall decomposition of the propellant RF-402. The lifetime of individual droplets will be analyzed using both experimental and theoretical techniques. The theoretical technique will involve modeling the lifetime of an individual droplet in a combustion chamber like operating environment

  5. To Your Health: NLM update transcript - Gun safety strategies

    Science.gov (United States)

    ... transcript040918.html To Your Health: NLM update Transcript Gun safety strategies : 04/09/2018 To use the ... on weekly topics. An evidence-based, public health gun safety strategy that is consistent with second amendment ...

  6. Goods for Guns--the use of a gun buyback as an injury prevention/community education tool.

    Science.gov (United States)

    McGuire, Margaret; Manno, Mariann; Rook, Allison; Maranda, Louise; Renaud, Elizabeth; DeRoss, Anthony; Hirsh, Michael

    2011-11-01

    US children aged between 5 years and 14 years have a rate of gun-related homicide 17 times higher and a rate of gun-related suicide and unintentional firearm injury 10 times higher than other developed countries. Gun buyback programs have been criticized as ineffective interventions in decreasing violence. The Injury Free Coalition for Kids-Worcester (IFCK-W) Goods for Guns buyback is a multipronged approach to address these concerns and to reduce the number of firearms in the community. The IFCK-W buyback program is funded by corporate sponsors, grants, and individual donations. Citizens are instructed to transport guns, ammunition, and weapons safely to police headquarters on two Saturdays in December. Participants are guaranteed anonymity by the District Attorney's office and receive gift certificates for operable guns. Trained volunteers administer an anonymous survey to willing participants. Individuals who disclose having unsafely stored guns remaining at home receive educational counseling and trigger locks. Guns and ammunition are destroyed at a later time in a gun crushing ceremony. Since 2002, 1,861 guns (444 rifle/shotgun, 738 pistol/revolver, and 679 automatic/semiautomatic) have been collected at a cost of $99,250 (average, $53/gun). Seven hundred ten people have surrendered firearms, 534 surveys have been administered, and ≈ 75 trigger locks have been distributed per year. IFCK-W Goods for Guns is a relatively inexpensive injury prevention model program that removes unwanted firearms from homes, raises community awareness about gun safety, and provides high-risk individuals with trigger locks and educational counseling.

  7. Design of a high repetition rate S-band photocathode gun

    International Nuclear Information System (INIS)

    Han Janghui; Cox, Matthew; Huang, Houcheng; Pande, Shivaji

    2011-01-01

    Photocathode RF guns have been developed in many laboratories for generating high quality electron beams for free-electron lasers based on linear accelerators. Such guns can generate electron beams with an exceptionally high peak current as well as a small transverse emittance. Their applications have been recently expanded for ultrafast electron diffraction, coherent terahertz radiation, and X-ray or γ-ray radiation by Compton scattering. In this paper, we design an S-band normal-conducting gun with capabilities of high quality beam generation and high repetition rate operation. The RF design and thermal analysis of the gun cavity and coupler are introduced. Optimal position of the gun focusing solenoid for low emittance beam generation is found by performing particle tracking simulations. Then, the gun system is designed to be able to afford the optimal solenoid position. The cooling-water channel surrounding the gun cavity and coupler is designed and analyzed numerically. The pressure in the gun is simulated with a vacuum model containing the detailed inner structure of the gun. An injector for a free-electron laser application is designed by using this gun and the beam dynamics simulation is shown. A cold test with a prototype gun for confirmation of the RF design is reported. - Highlights: → We design an S-band gun for low emittance beam generation and high repetition rate operation. → The RF design and thermal analysis of the gun cavity and coupler are studied. → An FEL injector is designed by using this gun and the beam dynamics simulation is shown. → A cold test with a prototype gun for confirmation of the RF design is reported.

  8. Design and implementation of a fs-resolved transmission electron microscope based on thermionic gun technology

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, L., E-mail: luca.piazza@epfl.ch [Laboratory for Ultrafast Microscopy and Electron Scattering (LUMES), ICMP, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Masiel, D.J. [Integrated Dynamic Electron Solutions, Inc., 455 Bolero Drive, Danville, CA 94526 (United States); LaGrange, T.; Reed, B.W. [Condensed Matter and Materials Division Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States); Barwick, B. [Department of Physics, Trinity College, 300 Summit St., Hartford, CT 06106 (United States); Carbone, Fabrizio [Laboratory for Ultrafast Microscopy and Electron Scattering (LUMES), ICMP, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland)

    2013-09-23

    Highlights: • We present the implementation of a femtosecond-resolved ultrafast TEM. • This is the first ultrafast TEM based on a thermionic gun geometry. • An additional condenser lens has been used to maximize the electron count. • We achieved a time resolution of about 300 fs and an energy resolution of 1 eV. - Abstract: In this paper, the design and implementation of a femtosecond-resolved ultrafast transmission electron microscope is presented, based on a thermionic gun geometry. Utilizing an additional magnetic lens between the electron acceleration and the nominal condenser lens system, a larger percentage of the electrons created at the cathode are delivered to the specimen without degrading temporal, spatial and energy resolution significantly, while at the same time maintaining the femtosecond temporal resolution. Using the photon-induced near field electron microscopy effect (PINEM) on silver nanowires the cross-correlation between the light and electron pulses was measured, showing the impact of the gun settings and initiating laser pulse duration on the electron bunch properties. Tuneable electron pulses between 300 fs and several ps can be obtained, and an overall energy resolution around 1 eV was achieved.

  9. Therminoic gun control system for the CEBAF injector

    International Nuclear Information System (INIS)

    Pico, R.; Diamond, B.; Fugitt, J.; Bork, R.

    1989-01-01

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  10. High burn rate solid composite propellants

    Science.gov (United States)

    Manship, Timothy D.

    High burn rate propellants help maintain high levels of thrust without requiring complex, high surface area grain geometries. Utilizing high burn rate propellants allows for simplified grain geometries that not only make production of the grains easier, but the simplified grains tend to have better mechanical strength, which is important in missiles undergoing high-g accelerations. Additionally, high burn rate propellants allow for a higher volumetric loading which reduces the overall missile's size and weight. The purpose of this study is to present methods of achieving a high burn rate propellant and to develop a composite propellant formulation that burns at 1.5 inches per second at 1000 psia. In this study, several means of achieving a high burn rate propellant were presented. In addition, several candidate approaches were evaluated using the Kepner-Tregoe method with hydroxyl terminated polybutadiene (HTPB)-based propellants using burn rate modifiers and dicyclopentadiene (DCPD)-based propellants being selected for further evaluation. Propellants with varying levels of nano-aluminum, nano-iron oxide, FeBTA, and overall solids loading were produced using the HTPB binder and evaluated in order to determine the effect the various ingredients have on the burn rate and to find a formulation that provides the burn rate desired. Experiments were conducted to compare the burn rates of propellants using the binders HTPB and DCPD. The DCPD formulation matched that of the baseline HTPB mix. Finally, GAP-plasticized DCPD gumstock dogbones were attempted to be made for mechanical evaluation. Results from the study show that nano-additives have a substantial effect on propellant burn rate with nano-iron oxide having the largest influence. Of the formulations tested, the highest burn rate was a 84% solids loading mix using nano-aluminum nano-iron oxide, and ammonium perchlorate in a 3:1(20 micron: 200 micron) ratio which achieved a burn rate of 1.2 inches per second at 1000

  11. The Effects of Cueing and Framing on Youth Attitudes towards Gun Control and Gun Rights

    Directory of Open Access Journals (Sweden)

    Stephen Wu

    2018-02-01

    Full Text Available I analyze attitudes towards gun control from a recent survey of American high school students. For students who most closely identify as Republicans, cueing them to think about prior school shootings increases their agreement that armed staff in schools will improve safety and arming citizens will reduce risk of mass shootings. For those identifying as Democrats and Independents, providing them with selective information that certain states have loose gun control laws and low rates of gun violence makes them more supportive of gun rights. For Republicans, providing selective information that certain states have loose gun control laws and high rates of gun violence makes them less supportive of gun rights. These results suggest that emotional cues may exacerbate a priori biases, while informational cues may be more likely to change people’s minds about firearm policies.

  12. Characterization of a dielectric barrier plasma gun discharging at atmospheric pressure

    International Nuclear Information System (INIS)

    Zhang Guangqiu; Ge Yuanjing; Zhang Yuefei; Chen Guangliang

    2004-01-01

    The authors develop a plasma gun based on dielectric barrier discharge and working at atmospheric pressure. A theoretical model to predict the gun discharge voltage is built, which is in agreement with the experimental results. After investigating the characterization of discharging gun and utilizing it for polymerization, authors find that the gun can be used as a source to generate a stable uniform plasma for different plasma-processing technologies. (author)

  13. Ballistics considerations for small-caliber, low-density projectiles

    International Nuclear Information System (INIS)

    Gouge, M.J.; Baylor, L.R.; Combs, S.K.; Fisher, P.W.; Foster, C.A.; Foust, C.R.; Milora, S.L.; Qualls, A.L.

    1993-01-01

    One major application for single- and two-stage light gas guns is for fueling magnetic fusion confinement devices. Powder guns are not a feasible alternative due to possible plasma contamination by residual powder gases and the eventual requirement of steady-state operation at ∼ 1 Hz, which will dictate a closed gas handling system where propellant gases are recovered, processed and recompressed. Interior ballistic calculations for single-stage light gas guns, both analytical and numerical, are compared to an extensive data base for low density hydrogenic projectiles (pellets). Some innovative range diagnostics are described for determining the size and velocity of these small (several mm) size projectiles. A conceptual design of a closed cycle propellant gas system is presented including tradeoffs between different light propellant gases

  14. Design and simulation on the morphing composite propeller (Conference Presentation)

    Science.gov (United States)

    Chen, Fanlong; Li, Qinyu; Liu, Liwu; Lan, Xin; Liu, Yanju; Leng, Jinsong

    2017-04-01

    As one of the most crucial part of the unmanned underwater vehicle (UUV), the composite propeller plays an important role on the UUV's performance. As the composite propeller behaves excellent properties in hydroelastic facet and acoustic suppression, it attracts increasing attentions all over the globe. This paper goes a step further based on this idea, and comes up with a novel concept of "morphing composite propeller" (MCP) to improve the performance of the conventional composite propeller (CCP) to anticipate the improved propeller can perform better to propel the UUV. Based on the new concept, a novel MCP is designed. Each blade of the propeller is assembled with an active rotatable flap (ARF) to change the blade's local camber with flap rotation. Then the transmission mechanism (TM) has been designed and housed in the propeller blade to push the ARF. With the ARF rotating, the UUV can be propelled by different thrusts under certain rotation velocities of the propeller. Based on the design, the Fluent is exploited to analyze the fluid dynamics around the propeller. Finally, based on the design and hydrodynamic analysis, the structural response for the novel morphing composite propeller is calculated. The propeller blade is simplified and layered with composite materials. And the structure response of an MCP is obtained with various rotation angle under the hydrodynamic pressure. This simulation can instruct the design and fabrication techniques of the MCP.

  15. The case for moderate gun control.

    Science.gov (United States)

    DeGrazia, David

    2014-03-01

    In addressing the shape of appropriate gun policy, this essay assumes for the sake of discussion that there is a legal and moral right to private gun ownership. My thesis is that, against the background of this right, the most defensible policy approach in the United States would feature moderate gun control. The first section summarizes the American gun control status quo and characterizes what I call "moderate gun control." The next section states and rebuts six leading arguments against this general approach to gun policy. The section that follows presents a positive case for moderate gun control that emphasizes safety in the home and society as well as rights whose enforcement entails some limits or qualifications on the right to bear arms. A final section shows how the recommended gun regulations address legitimate purposes, rather than imposing arbitrary restrictions on gun rights, and offers concluding reflections.

  16. ORELA electron guns

    International Nuclear Information System (INIS)

    Christian, O.W.; Lewis, T.A.

    1981-09-01

    The most recent information concerning the production and performance of ORELA electron guns is presented. Included are descriptions of procedures for gun fabrication, cathode conditioning and high voltage processing. Highlights of the performance characteristics are also included

  17. RF Design of the LCLS Gun

    International Nuclear Information System (INIS)

    Limborg-Deprey, C.

    2010-01-01

    Final dimensions for the LCLS RF gun are described. This gun, referred to as the LCLS gun, is a modified version of the UCLA/BNL/SLAC 1.6 cell S-Band RF gun (1), referred to as the prototype gun. The changes include a larger mode separation (15 MHz for the LCLS gun vs. 3.5 MHz for the prototype gun), a larger radius at the iris between the 2 cells, a reduced surface field on the curvature of the iris between the two cells, Z power coupling, increased cooling channels for operation at 120 Hz, dual rf feed, deformation tuning of the full cell, and field probes in both cells. Temporal shaping of the klystron pulse, to reduce the average power dissipated in the gun, has also been adopted. By increasing the mode separation, the amplitude of the 0-mode electric field on the cathode decreases from 10% of the peak on axis field for the prototype gun to less than 3% for the LCLS gun for the steady state fields. Beam performance is improved as shown by the PARMELA simulations. The gun should be designed to accept a future load lock system. Modifications follow the recommendations of our RF review committee (2). Files and reference documents are compiled in Section IV.

  18. Laser-propelled ram accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Sasoh, A. [Tohoku Univ., Sendai (Japan). Inst. of Fluid Science

    2000-11-01

    The concept of 'laser-propelled ram accelerator (L-RAMAC)' is proposed. Theoretically it is capable of achieving a higher launch speed than that by a chemical ram accelerator because a higher specific energy can be input to the propellant gas. The laser beam is supplied through the muzzle, focused as an annulus behind the base of the projectile. The performance of L-RAMAC is analized based on generalized Rankine-Hugoniot relations, suggesting that a superorbital muzzle speed is achievable out of this device. (orig.)

  19. Application of electron beam equipment based on a plasma cathode gun in additive technology

    Science.gov (United States)

    Galchenko, N. K.; Kolesnikova, K. A.; Semenov, G. V.; Rau, A. G.; Raskoshniy, S. Y.; Bezzubko, A. V.; Dampilon, B. V.; Sorokova, S. N.

    2016-11-01

    The paper discusses the application of electron beam equipment based on a plasma cathode gun for three-dimensional surface modification of metals and alloys. The effect of substrate surface preparation on the adhesion strength of gas thermal coatings has been investigated.

  20. Characterisation of 100 kW electron beam melting gun and its adaptation as electron gun for high power DC electron accelerators

    International Nuclear Information System (INIS)

    Banerjee, Srutarshi; Bhattacharjee, Dhruva; Waghmare, Abhay; Tiwari, Rajnish; Bakhtsingh, R.I.; Dasgupta, K.; Gupta, Sachin; Prakash, Baibhaw; Jha, M.N.

    2015-01-01

    The paper deals with the characterization of the 100 kW electron beam melting gun for its adaptation in high power DC Electron Accelerators. The indigenously designed electron beam melting system at BARC is chosen for characterization. It comprises of electron gun as source of electrons, two electromagnetic focusing lenses viz. upper focusing lens and lower focusing lens for beam focusing, intermediate beam aperture for vacuum decoupling between gun region and melt zone, deflection and oscillation lens for maneuvering the beam on the melt charge and water cooled crucible that acts as a beam dump. In this system, the electron gun is designed for 40 kV and 100 kW corresponding to a maximum beam current of 2.5 A. The electron gun uses directly heated spiral tungsten filament. The operating temperature of the filament is 2800 °K. The focusing electrode and the anode profile are designed based on Pierce geometry. High Power DC Electron Accelerators require high currents of 1 A. The beam must comply with the requirement of 40 mm beam diameter and 10 mrad divergence at the exit of the electron gun. The characterization of the existing electron gun was done to find out all the beam parameters, for e.g. beam size, beam divergence, perveance etc. to be adapted or to be modified for the design of electron gun for high power DC accelerators. This paper shows limitations and the possible solutions for design of high power DC accelerators. (author)

  1. Grip-pattern recognition: Applied to a smart gun

    NARCIS (Netherlands)

    Shang, X.

    2008-01-01

    In our work the verification performance of a biometric recognition system based on grip patterns, as part of a smart gun for use by the police ocers, has been investigated. The biometric features are extracted from a two-dimensional pattern of the pressure, exerted on the grip of a gun by the hand

  2. Gun violence in Americans' social network during their lifetime.

    Science.gov (United States)

    Kalesan, Bindu; Weinberg, Janice; Galea, Sandro

    2016-12-01

    The overall burden of gun violence death and injury in the US is now well understood. However, no study has shown the extent to which gun violence is associated with the individual lives of Americans. We used fatal and non-fatal gun injury rates in 2013 from Centers for Disease Control and Prevention's Web-based Injury Statistics Query and Reporting System (WISQARS) and generally accepted estimates about the size of an American's social network to determine the likelihood that any given person will know someone in their personal social network who is a victim of gun violence during their lifetime. We derived estimates in the overall population and among racial/ethnic groups and by gun-injury intent. The likelihood of knowing a gun violence victim within any given personal network over a lifetime is 99.85% (99.8% to 99.9%). The likelihood among non-Hispanic white, black, Hispanic and other race Americans were 97.1%, 99.9%, 99.5% and 88.9% respectively. Nearly all Americans of all racial/ethnic groups are likely to know a victim of gun violence in their social network during their lifetime. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Gun Violence Following Inpatient Psychiatric Treatment: Offense Characteristics, Sources of Guns, and Number of Victims.

    Science.gov (United States)

    Kivisto, Aaron J

    2017-10-01

    This study presents data on the relative contribution to gun violence by people with a history of inpatient psychiatric treatment and on federal efforts to deter presumptively dangerous persons from obtaining firearms, information useful for analyzing the potential public health benefits of gun policies targeting people with serious mental illness. The study also estimates the reduction in gun violence victims that would be expected if individuals with a previous psychiatric hospitalization were prohibited from purchasing firearms. Data from 838 violent gun offenders from a nationally representative sample of state prison inmates were analyzed. Those with and without a history of psychiatric hospitalization were compared on a range of offense characteristics, including relationship to the victim, number of victims, location of the offense, and source of firearms. Inmates with a history of hospitalization constituted 12% of all violent gun offenders and accounted for 13% of the sample's victims. They were less likely than those without a previous hospitalization to victimize strangers (odds ratio=.52) and were no more likely to commit gun violence in public or to have multiple victims. Among those with previous hospitalizations, 78% obtained guns from sources not subject to federal background checks. Of the total 1,041 victims of gun violence, only 3% were victimized by participants with a history of hospitalization who obtained guns from currently regulated sources. Prohibiting all individuals with a history of psychiatric hospitalization from purchasing firearms, absent expanded background checks, was estimated to reduce the number of gun violence victims by only 3%.

  4. Unbalanced field RF electron gun

    Science.gov (United States)

    Hofler, Alicia

    2013-11-12

    A design for an RF electron gun having a gun cavity utilizing an unbalanced electric field arrangement. Essentially, the electric field in the first (partial) cell has higher field strength than the electric field in the second (full) cell of the electron gun. The accompanying method discloses the use of the unbalanced field arrangement in the operation of an RF electron gun in order to accelerate an electron beam.

  5. Prospects for deflagration guns

    International Nuclear Information System (INIS)

    Cheng, D.Y.; Tripathi, P.P.; Chang, C.N.

    1978-01-01

    Deflagration is a process of fluid expansion with energy addition. Its existence in plasma physics was first discovered in the back-strapped T-tube experiments. In the coaxial plasma gun configuration the operation can be simple and yet produce a clean, high density (5 x 10 15 cm -3 ), and high kinetic energy (10 to 50 keV) collimated plasma beam. Plasma acceleration mechanism was thought to be driven by J x B force. Tapered electrodes have been used to obtain plasma beams. Scaling of the gun can be performed according to simple theory based on momentum and energy balance. Proposed plasma fueling and injection to magnetic fusion systems will be discussed

  6. From gun politics to self-defense politics: a feminist critique of the great gun debate.

    Science.gov (United States)

    Carlson, Jennifer D

    2014-03-01

    This article calls attention to a problematic binary produced by public debates surrounding gun rights and gun control-namely, that women must choose armed self-protection or no self-protection at all. I argue that both anti- and pro-gun discourses, drawing on and reproducing race and class privileges, use assumptions about women's physical inferiority to further their agendas. I highlight how both sides have used guns as the proxy for self-defense and conclude by calling for a shift in public discourse to focus on the broader question of the right to self-defense rather than the narrower question of gun rights.

  7. Momentum equation for arc-driven rail guns

    International Nuclear Information System (INIS)

    Batteh, J.H.

    1984-01-01

    In several models of arc-driven rail guns, the rails are assumed to be infinitely high to simplify the calculation of the electromagnetic fields which appear in the momentum equation for the arc. This assumption leads to overestimates of the arc pressures and accelerations by approximately a factor of 2 for typical rail-gun geometries. In this paper, we develop a simple method for modifying the momentum equation to account for the effect of finite-height rails on the performance of the rail gun and the properties of the arc. The modification is based on an integration of the Lorentz force across the arc cross section at each axial location in the arc. Application of this technique suggests that, for typical rail-gun geometries and moderately long arcs, the momentum equation appropriate for infinite-height rails can be retained provided that the magnetic pressure term in the equation is scaled by a factor which depends on the effective inductance of the gun. The analysis also indicates that the magnetic pressure gradient actually changes sign near the arc/projectile boundary because of the magnetic fields associated with the arc current

  8. Energy coefficients for a propeller series

    DEFF Research Database (Denmark)

    Olsen, Anders Smærup

    2004-01-01

    The efficiency for a propeller is calculated by energy coefficients. These coefficients are related to four types of losses, i.e. the axial, the rotational, the frictional, and the finite blade number loss, and one gain, i.e. the axial gain. The energy coefficients are derived by use...... of the potential theory with the propeller modelled as an actuator disk. The efficiency based on the energy coefficients is calculated for a propeller series. The results show a good agreement between the efficiency based on the energy coefficients and the efficiency obtained by a vortex-lattice method....

  9. A high-brightness thermionic microwave electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Borland, Michael [Stanford Univ., CA (United States)

    1991-02-01

    In a collaborative effort by SSRL, AET Associates, and Varian Associates, a high-brightness microwave electron gun using a thermionic cathode has been designed, built, tested, and installed for use with the SSRL 150 MeV linear accelerator. This thesis discusses the physics behind the design and operation of the gun and associated systems, presenting predictions and experimental tests of the gun`s performance. The microwave gun concept is of increasing interest due to its promise of providing higher-current, lower-emittance electron beams than possible from conventional, DC gun technology. In a DC guns, accelerating gradients are less than 8 MV/m, while those in a microwave gun can exceed 100 MV/m, providing much more rapid initial acceleration, thereby reducing the deleterious effects of space-charge. Microwave guns produce higher momentum beams than DC guns, thus lessening space-charge effects during subsequent beam transport. Typical DC guns produce kinetic energies of 80--400 KeV, compared to 2--3 MeV for the SSRL microwave gun. ``State-of-the-art`` microwave gun designs employ laser-driven photocathodes, providing excellent performance but with greater complexity and monetary costs. A thermionic microwave gun with a magnetic bunching system is comparable in cost and complexity to a conventional system, but provides performance that is orders of magnitude better. Simulations of the SSRL microwave gun predict a normalized RMS emittance at the gun exist of < 10 π • mec • μm for a beam consisting of approximately 50% of the particles emitted from the gun, and having a momentum spread ±10%. These emittances are for up to 5 x 109e- per bunch. Chromatic aberrations in the transport line between the gun and linear accelerator increase this to typically < 30 π • me • μm.

  10. Hard-driven rail-gun tests

    International Nuclear Information System (INIS)

    Peterson, D.R.; Adams, D.F.; Cummings, C.E.; Fowler, C.M.; Kerrisk, J.F.; Marsh, S.P.; Parker, J.V.

    1983-01-01

    A number of prototype rail-gun designs have been tested, powered by explosive magnetic flux compression generators. Peak currents as high as 1.3 MA were delivered. Rail guns with 50-mm-thick Kevlar fiberwound structural shells were able to survive these high currents with minimum mechanical damage and were refired after enlarging the bores 0.2 to 0.4 mm to remove arc damage. In some tests, mechanical damage occurred that was apparently caused by the rebound of the gun after firing. Although the Kevlar shells had more than adequate strength, they appeared to lack sufficient stiffness, allowing excessive deflections. The use of a steel structural shell with a Kevlar sleeve was an improvement. Intrusion into the seams of the rail guns and condensation of material from the plasma armature were observed. Improved sealing of seams is indicated. In some cases, we suspect maldistribution of current within the gun; that is, not all the current delivered to the breech of the gun seemed to reach the plasma armature. Experiments are being designed to quantify the effects discussed. Rail guns of advanced design are being fabricated. An 18-g titanium projectile was accelerated to 2.4 km/s in a 16-mm-round-bore, 0.6-m-long gun, 4-6 g polycarbonate projectiles were accelerated to 3.5 km/s in 13-mm-square-bore, 1.2-m-long rail guns. All tests were conducted at atmospheric pressure

  11. A high-brightness thermionic microwave electron gun

    International Nuclear Information System (INIS)

    Borland, M.

    1991-02-01

    In a collaborative effort by SSRL, AET Associates, and Varian Associates, a high-brightness microwave electron gun using a thermionic cathode has been designed, built, tested, and installed for use with the SSRL 150 MeV linear accelerator. This thesis discusses the physics behind the design and operation of the gun and associated systems, presenting predictions and experimental tests of the gun's performance. The microwave gun concept is of increasing interest due to its promise of providing higher-current, lower-emittance electron beams than possible from conventional, DC gun technology. In a DC guns, accelerating gradients are less than 8 MV/m, while those in a microwave gun can exceed 100 MV/m, providing much more rapid initial acceleration, thereby reducing the deleterious effects of space-charge. Microwave guns produce higher momentum beams than DC guns, thus lessening space-charge effects during subsequent beam transport. Typical DC guns produce kinetic energies of 80--400 KeV, compared to 2--3 MeV for the SSRL microwave gun. ''State-of-the-art'' microwave gun designs employ laser-driven photocathodes, providing excellent performance but with greater complexity and monetary costs. A thermionic microwave gun with a magnetic bunching system is comparable in cost and complexity to a conventional system, but provides performance that is orders of magnitude better. Simulations of the SSRL microwave gun predict a normalized RMS emittance at the gun exist of e c · μm for a beam consisting of approximately 50% of the particles emitted from the gun, and having a momentum spread ±10%. These emittances are for up to 5 x 10 9 e - per bunch. Chromatic aberrations in the transport line between the gun and linear accelerator increase this to typically e · μm

  12. Drag and Torque on Locked Screw Propeller

    Directory of Open Access Journals (Sweden)

    Tomasz Tabaczek

    2014-09-01

    Full Text Available Few data on drag and torque on locked propeller towed in water are available in literature. Those data refer to propellers of specific geometry (number of blades, blade area, pitch and skew of blades. The estimation of drag and torque of an arbitrary propeller considered in analysis of ship resistance or propulsion is laborious. The authors collected and reviewed test data available in the literature. Based on collected data there were developed the empirical formulae for estimation of hydrodynamic drag and torque acting on locked screw propeller. Supplementary CFD computations were carried out in order to prove the applicability of the formulae to modern moderately skewed screw propellers.

  13. Effects of magnesium-based hydrogen storage materials on the thermal decomposition, burning rate, and explosive heat of ammonium perchlorate-based composite solid propellant.

    Science.gov (United States)

    Liu, Leili; Li, Jie; Zhang, Lingyao; Tian, Siyu

    2018-01-15

    MgH 2 , Mg 2 NiH 4 , and Mg 2 CuH 3 were prepared, and their structure and hydrogen storage properties were determined through X-ray photoelectron spectroscopy and thermal analyzer. The effects of MgH 2 , Mg 2 NiH 4 , and Mg 2 CuH 3 on the thermal decomposition, burning rate, and explosive heat of ammonium perchlorate-based composite solid propellant were subsequently studied. Results indicated that MgH 2 , Mg 2 NiH 4 , and Mg 2 CuH 3 can decrease the thermal decomposition peak temperature and increase the total released heat of decomposition. These compounds can improve the effect of thermal decomposition of the propellant. The burning rates of the propellant increased using Mg-based hydrogen storage materials as promoter. The burning rates of the propellant also increased using MgH 2 instead of Al in the propellant, but its explosive heat was not enlarged. Nonetheless, the combustion heat of MgH 2 was higher than that of Al. A possible mechanism was thus proposed. Copyright © 2017. Published by Elsevier B.V.

  14. Effect of Propellant Composition to the Temperature Sensitivity of Composite Propellant

    International Nuclear Information System (INIS)

    Aziz, Amir; Mamat, Rizalman; Amin, Makeen; Wan Ali, Wan Khairuddin

    2012-01-01

    The propellant composition is one of several parameter that influencing the temperature sensitivity of composite propellant. In this paper, experimental investigation of temperature sensitivity in burning rate of composite propellant was conducted. Four sets of different propellant compositions had been prepared with the combination of ammonium perchlorate (AP) as an oxidizer, aluminum (Al) as fuel and hydroxy-terminated polybutadiene (HTPB) as fuel and binder. For each mixture, HTPB binder was fixed at 15% and cured with isophorone diisocyanate (IPDI). By varying AP and Al, the effect of oxidizer- fuel mixture ratio (O/F) on the whole propellant can be determined. The propellant strands were manufactured using compression molded method and burnt in a strand burner using wire technique over a range of pressure from 1 atm to 31 atm. The results obtained shows that the temperature sensitivity, a, increases with increasing O/F. Propellant p80 which has O/F ratio of 80/20 gives the highest value of temperature sensitivity which is 1.687. The results shows that the propellant composition has significant effect on the temperature sensitivity of composite propellant

  15. Self-bunching electron guns

    CERN Document Server

    Mako, F; Weilhammer, Peter

    1999-01-01

    We report on three electron gun projects that are aimed at power tube and injector applications. The purpose of the work is to develop robust electron guns which produce self-bunched, high-current-density beams. We have demonstrated cold emission, long life, and tolerance to contamination. The cold emission process is based on secondary electron emission. FMT has studied this resonant bunching process which gives rise to high current densities (0.01-5 kA/cm/sup 2/), high charge bunches (up to 100 nC/bunch), and short pulses (1-100 ps) for frequencies from 1 to 12 GHz. The beam pulse width is nominally ~5% of the RF period. The first project is the L-Band Micro-Pulse Gun (MPG). Measurements show ~40 ps long microbunches at ~20 A/cm/sup 2/ without contamination due to air exposure. Lifetime testing has been carried out for about 18 months operating at 1.25 GHz for almost 24 hours per day at a repetition rate of 300 Hz and 5 mu s-long macro- pulses. About 5.8*10/sup 13/ micro-bunches or 62,000 coulombs have pass...

  16. An RF ion source based primary ion gun for secondary ion mass spectroscopy

    International Nuclear Information System (INIS)

    Menon, Ranjini; Nabhiraj, P.Y.; Bhandari, R.K.

    2011-01-01

    In this article we present the design, development and characterization of an RF plasma based ion gun as a primary ion gun for SIMS application. RF ion sources, in particular Inductively Coupled Plasma (ICP) ion sources are superior compared to LMIS and duoplasmtron ion sources since they are filamentless, can produce ions of gaseous elements. At the same time, ICP ion sources offer high angular current density which is an important factor in producing high current in small spot size on the target. These high current microprobes improve the signal to noise ratio by three orders as compared to low current ion sources such as LMIS. In addition, the high current microprobes have higher surface and depth profiling speeds. In this article we describe a simple ion source in its very basic form, two lens optical column and characteristics of microprobe

  17. Racism, Gun Ownership and Gun Control: Biased Attitudes in US Whites May Influence Policy Decisions

    OpenAIRE

    O?Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    OBJECTIVE: Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. METHOD: The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US wh...

  18. Mirrored continuum and molecular scale simulations of the ignition of gamma phase RDX

    Science.gov (United States)

    Stewart, D. Scott; Chaudhuri, Santanu; Joshi, Kaushik; Lee, Kibaek

    2017-01-01

    We describe the ignition of an explosive crystal of gamma-phase RDX due to a thermal hot spot with reactive molecular dynamics (RMD), with first-principles trained, reactive force field based molecular potentials that represents an extremely complex reaction network. The RMD simulation is analyzed by sorting molecular product fragments into high and low molecular weight groups, to represent identifiable components that can be interpreted by a continuum model. A continuum model based on a Gibbs formulation has a single temperature and stress state for the mixture. The continuum simulation that mirrors the atomistic simulation allows us to study the atomistic simulation in the familiar physical chemistry framework and provides an essential, continuum/atomistic link.

  19. CID thermionic gun system

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1981-10-01

    A new high-current thermionic gun has been installed on the CID injector at SLAC and brought into operation. The gun and pulser system generate three nanosecond pulses of about six amps peak which, when bunched in the subharmonic buncher system, produce in excess of 10 11 electrons in a single S-band accelerated bunch. Preliminary operation of the gun is described, and details of the avalanche cathode drive pulser are presented

  20. CID thermionic gun system

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1982-01-01

    A new high-current thermionic gun has been installed on the CID injector at SLAC and brought into operation. The gun and pulser system generate three nanosecond pulses of about six amps peak which, when bunched in the subharmonic buncher system, produce in excess of 10 11 electrons in a single S-band accelerated bunch. Preliminary operation of the gun is described, and details of the avalanche cathode drive pulser are presented

  1. X-Band RF Gun Development

    International Nuclear Information System (INIS)

    Vlieks, A.E.

    2012-01-01

    In support of the MEGa-ray program at LLNL and the High Gradient research program at SLAC, a new X-band multi-cell RF gun is being developed. This gun, similar to earlier guns developed at SLAC for Compton X-ray source program, will be a standing wave structure made of 5.5 cells operating in the pi mode with copper cathode. This gun was designed following criteria used to build SLAC X-band high gradient accelerating structures. It is anticipated that this gun will operate with surface electric fields on the cathode of 200 MeV/m with low breakdown rate. RF will be coupled into the structure through a final cell with symmetric duel feeds and with a shape optimized to minimize quadrupole field components. In addition, geometry changes to the original gun, operated with Compton X-ray source, will include a wider RF mode separation, reduced surface electric and magnetic fields.

  2. Gun violence trends in movies.

    Science.gov (United States)

    Bushman, Brad J; Jamieson, Patrick E; Weitz, Ilana; Romer, Daniel

    2013-12-01

    Many scientific studies have shown that the mere presence of guns can increase aggression, an effect dubbed the "weapons effect." The current research examines a potential source of the weapons effect: guns depicted in top-selling films. Trained coders identified the presence of violence in each 5-minute film segment for one-half of the top 30 films since 1950 and the presence of guns in violent segments since 1985, the first full year the PG-13 rating (age 13+) was used. PG-13-rated films are among the top-selling films and are especially attractive to youth. Results found that violence in films has more than doubled since 1950, and gun violence in PG-13-rated films has more than tripled since 1985. When the PG-13 rating was introduced, these films contained about as much gun violence as G (general audiences) and PG (parental guidance suggested for young children) films. Since 2009, PG-13-rated films have contained as much or more violence as R-rated films (age 17+) films. Even if youth do not use guns, these findings suggest that they are exposed to increasing gun violence in top-selling films. By including guns in violent scenes, film producers may be strengthening the weapons effect and providing youth with scripts for using guns. These findings are concerning because many scientific studies have shown that violent films can increase aggression. Violent films are also now easily accessible to youth (e.g., on the Internet and cable). This research suggests that the presence of weapons in films might amplify the effects of violent films on aggression.

  3. Low emittance thermionic electron guns

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1989-01-01

    The author discusses self-field effects and external field effects for electron guns. He also discusses designs of electron guns and their uses in electron cooling systems and as an injector for electrostatic free electron lasers. He closes by looking at electron guns for linear accelerators. 20 references, 3 figures

  4. Guns at College.

    Science.gov (United States)

    Miller, Matthew; Hemenway, David; Wechsler, Henry

    1999-01-01

    Surveyed undergraduate students nationwide concerning firearm possession. About 3.5% possessed working firearms. Students with guns were more likely to be male, White, or Native American; binge drink; live off-campus; and live with a spouse or significant other. Students with guns were more likely to engage in activities that put themselves and…

  5. Relationship between licensing, registration, and other gun sales laws and the source state of crime guns.

    Science.gov (United States)

    Webster, D W; Vernick, J S; Hepburn, L M

    2001-09-01

    To determine the association between licensing and registration of firearm sales and an indicator of gun availability to criminals. Tracing data on all crime guns recovered in 25 cities in the United States were used to estimate the relationship between state gun law categories and the proportion of crime guns first sold by in-state gun dealers. In cities located in states with both mandatory registration and licensing systems (five cities), a mean of 33.7% of crime guns were first sold by in-state gun dealers, compared with 72.7% in cities that had either registration or licensing but not both (seven cities), and 84.2% in cities without registration or licensing (13 cites). Little of the difference between cities with both licensing and registration and cities with neither licensing nor registration was explained by potential confounders. The share of the population near a city that resides in a neighboring state without licensing or registration laws was negatively associated with the outcome. States with registration and licensing systems appear to do a better job than other states of keeping guns initially sold within the state from being recovered in crimes. Proximity to states without these laws, however, may limit their impact.

  6. Model-based Diagnostics for Propellant Loading Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — The loading of spacecraft propellants is a complex, risky operation. Therefore, diagnostic solutions are neces- sary to quickly identify when a fault occurs, so that...

  7. Results of the AFWL deflagration gun experiments

    International Nuclear Information System (INIS)

    Hackett, K.E.; Baker, W.L.; Beason, J.D.

    1987-01-01

    The snowplow and deflagration modes of coaxial plasma gun operation have been experimentally investigated and computationally simulated at the Air Force Weapons Laboratory. The snowplow mode occurs when the gun is prefilled to a uniform gas density. The initial breakdown forms near the insulator at the gun breech. It heats the gas and creates a shock wave that travels down the gun, ionizing gas and producing a thin current sheath that travels just behind the shock front. The shock front piles up the gas in front of itself as it moves down the gun - hence the name ''snowplow''. Deflagration occurs when gas is injected into an evacuated gun so that the initial breakdown forms as the gas fills the gun. The ionized gas is accelerated into the vacuum region carrying current and magnetic field with it. A quasi-stationary diffuse discharge develops. Gas still entering the gun is processed through the deflagrating discharge and accelerated out the gun muzzle

  8. RF guns: a review

    International Nuclear Information System (INIS)

    Travier, C.

    1990-06-01

    Free Electron Lasers and future linear colliders require very bright electron beams. Conventional injectors made of DC guns and RF bunchers have intrinsic limitations. The recently proposed RF guns have already proven their capability to produce bright beams. The necessary effort to improve further these performances and to gain reliability is now undertaken by many laboratories. More than twenty RF gun projects both thermionic and laser-driven are reviewed. Their specific characteristics are outlined and their nominal performances are given

  9. THE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN FOR ARTIFICIAL INSEMINATION (AI USING GOAT FRESH SEMEN

    Directory of Open Access Journals (Sweden)

    Mirsa Ita Dewi

    2017-03-01

    Full Text Available Electrical Insemination Gun (EI-GUN was a tool for Artificial Insemination (AI using fresh semen with an electric control system. The research objective was to produced EI-GUN for AI using fresh semen on small ruminants (goat. The research was conducted from March to June 2015. The process of EI-GUN creation implemented in Design and Prototype Laboratory and Aero Modeling Research Laboratory at Engineering Faculty, University of Brawijaya (UB. Testing tools EI-GUN on goat was conducted in the Sumber Sekar Laboratory, Animal Husbandry Faculty, UB.  The methods of research were literature study, tool specification determination, designing EI-GUN, running test, semen evaluation passed EI-GUN and application on Goat. EI-GUN has seven important parts, which supports each other in this operating system. Those parts consist of stylet, servo, system controlled, insemination pump, connecting rod, battery, and holder. EI-GUN work system sucked the semen into insemination pump as much as 5 ml, and release the semen 0.25 ml appropriate standard of AI. It was applicable for 20 times AI. The results showed that the cell motility of spermatozoa ≥ 70% were still in ranging of Indonesian National Standard (SNI.   Keywords: artificial insemination, EI-GUN, fresh semen.

  10. Differences Between New and Long-Standing US Gun Owners: Results From a National Survey.

    Science.gov (United States)

    Wertz, Joseph; Azrael, Deborah; Hemenway, David; Sorenson, Susan; Miller, Matthew

    2018-07-01

    To quantify the proportion of current US gun owners who are new to owning firearms and compare new versus long-standing gun owners with respect to their firearms and firearm-related behaviors. We performed a cross-sectional analysis of a nationally representative probability-based online survey conducted in 2015 in the United States. We defined new gun owners as current firearm owners who acquired all of their firearms within the past 5 years, but who lived in a home without a gun at some time over the past 5 years. We defined long-standing firearm owners as all other current gun owners. New gun owners represented 10% of all current US adult gun owners. In addition to being younger than long-standing gun owners, new gun owners were more likely to be liberal, own fewer guns, own handguns, own guns only for protection, and store guns in a safe manner. Gun ownership is dynamic, with approximately 1 million Americans becoming new gun owners each year. Public Health Implications. Clinical guidelines should be updated to explicitly endorse re-evaluating household firearm status at regular intervals.

  11. Shock loading and reactive flow modeling studies of void induced AP/AL/HTPB propellant

    Science.gov (United States)

    Miller, P. J.; Lindfors, A. J.

    1998-07-01

    The unreactive Hugoniot of a class 1.3 propellant has been investigated by shock compression experiments. The results are analyzed in terms of an ignition and growth reactive flow model using the DYNA2D hydrocode. The calculated shock ignition parameters of the model show a linear dependence on measured void volume which appears to reproduce the observed gauge records well. Shock waves were generated by impact in a 75 mm single stage powder gun. Manganin and PVDF pressure gauges provided pressure-time histories to 140 kbar. The propellants were of similar formulation differing only in AP particle size and the addition of a burn rate modifer (Fe2O3) from that of previous investigations. Results show neglible effect of AP particle size on shock response in contrast to the addition of Fe2O3 which appears to `stiffen' the unreactive Hugoniot and enhances significantly the reactive rates under shock. The unreactive Hugoniot, within experimental error, compares favorably to the solid AP Hugoniot. Shock experiments were performed on propellant samples strained to induce insitu voids. The material state was quantified by uniaxial tension dialatometry. The experimental records show a direct correlation between void volume (0 to 1.7%) and chemical reactivity behind the shock front. These results are discussed in terms of `hot spot' ignition resulting from the shock collapse of the voids.

  12. Electron gun for SSRF

    International Nuclear Information System (INIS)

    Sheng Shugang; Lin Guoqiang; Gu Qiang; Li Deming

    2003-01-01

    A 100 kV triode-electron-gun has been designed and manufactured for the Linac of Shanghai Synchrotron Radiation Facility (SSRF). In this paper the performance of the gun and some key components are described

  13. Automatic targeting of plasma spray gun

    Science.gov (United States)

    Abbatiello, Leonard A.; Neal, Richard E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is provided. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun.

  14. Automatic targeting of plasma spray gun

    International Nuclear Information System (INIS)

    Abbatiello, L.A.; Neal, R.E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is described. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun

  15. Electron gun for technological linear accelerator

    International Nuclear Information System (INIS)

    Khodak, I.V.; Kushnir, V.A.; Mirochenko, V.V.; Stepin, D.L.; Zavada, L.M.

    2000-01-01

    The work is purposed to the design of diode electron gun for powerful technologic electron linac and to experimental investigations of the beam parameters at the gun exit.The gun feature is the quick cathode replacement.This is very impotent for operating of the accelerator.The gun optics and beam parameters were calculated using the EGUN code.Beam parameters were investigated as at the special test stand so as component of the linac injector.The gun produces the beam current of 2 A at the anode voltage 25 kV.Measured beam parameters correspond to calculated results

  16. Are "goods for guns" good for the community? An update of a community gun buyback program.

    Science.gov (United States)

    Green, Jonathan; Damle, Rachelle N; Kasper, Rebecca E; Violano, Pina; Manno, Mariann; Nazarey, Pradeep P; Aidlen, Jeremy T; Hirsh, Michael P

    2017-08-01

    Gun violence remains a leading cause of death in the United States. Community gun buyback programs provide an opportunity to dispose of extraneous firearms. The purpose of this study was to understand the demographics, motivation, child access to firearms, and household mental illness of buyback participants in hopes of improving the program's effectiveness. A 2015 Injury Free Coalition for Kids gun buyback program which collaborated with local police departments was studied. We administered a 23-item questionnaire survey to gun buyback participants assessing demographic characteristics, motivation for relinquishing firearms, child firearm accessibility, and mental illness/domestic violence history. A total of 186 individuals from Central/Western Massachusetts turned in 339 weapons. Participants received between US $25 and US $75 in gift cards dependent on what type of gun was turned in, with an average cost of $41/gun. A total of 109 (59%) participants completed the survey. Respondents were mostly white (99%), men (90%) and first-time participants in the program (85.2%). Among survey respondents, 54% turned in firearms "for safety reasons." Respondents reported no longer needing/wanting their weapons (47%) and approximately one in eight participants were concerned the firearm(s) were accessible to children. Most respondents (87%) felt the program encouraged neighborhood awareness of firearm safety. Three of every five participants reported that guns still remained in their homes; additionally, 21% where children could potentially access them and 14% with a history of mental illness/suicide/domestic violence in the home. Gun buybacks can provide a low-cost means of removing unwanted firearms from the community. Most participants felt their homes were safer after turning in the firearm(s). In homes still possessing guns, emphasis on secure gun storage should continue, increasing the safety of children and families. The results of this survey also provided new

  17. The ALS Gun Electronics system

    International Nuclear Information System (INIS)

    Lo, C.C.

    1993-05-01

    The ALS Gun Electronics system has been designed to accommodate gun with a custom made socket and high speed electronics circuit which is capable of producing single and multiple electron bunches with time jitters measured at better than 50 PS. The system generates the gated RF signal at ground level before sending it up to the 120 KV-biased gun deck via a fiber optic cable. The current pulse width as a function of grid bias, using an Eimac 8847A planar triode simulating an electron gun, was measured to show the relationship between the two parameters

  18. The ALS gun electronics system

    International Nuclear Information System (INIS)

    Lo, C.C.

    1993-01-01

    The ALS Gun Electronics system has been designed to accommodate the gun with a custom made socket and a high speed electronics circuit which is capable of producing single and multiple electron bunches with time jitters measured at better than 50 PS. The system generates the gated RF signal at ground level before sending it up to the 120 KV-biased gun deck via a fiber optic cable. The current pulse width as a function of grid bias, using an Eimac 8847A planar triode simulating an electron gun, was measured to show the relationship between the two parameters

  19. Tip-modified Propellers

    DEFF Research Database (Denmark)

    Andersen, Poul

    1999-01-01

    The paper deals with tip-modified propellers and the methods which, over a period of two decades, have been applied to develop such propellers. The development is driven by the urge to increase the efficiency of propellers and can be seen as analogous to fitting end plates and winglets to aircraft...... propeller, have efficiency increases of a reasonable magnitude in both open-water and behind-ship conditions....

  20. A ferroelectric electron gun in a free-electron maser experiment

    International Nuclear Information System (INIS)

    Einat, M.; Jerby, E.; Rosenman, G.

    2002-01-01

    An electron-gun based on a ferroelectric cathode is studied in a free-electron maser (FEM) experiment. In this gun, the electrons are separated from the cathode surface plasma, and are accelerated in two stages. The electron energy-spread is reduced sufficiently for an FEM operation in the microwave regime. A 14 keV, 1-2 A e-beam is obtained in a 0.1-2.1 μs pulse width. The pulse repetition frequency attains 3.1 MHz in ∼50% duty-cycle. This gun is implemented in an FEM oscillator experiment operating around 3 GHz. The paper presents experimental results and discusses the applicability of ferroelectric guns in free-electron laser devices

  1. A ferroelectric electron gun in a free-electron maser experiment

    CERN Document Server

    Einat, M; Rosenman, G

    2002-01-01

    An electron-gun based on a ferroelectric cathode is studied in a free-electron maser (FEM) experiment. In this gun, the electrons are separated from the cathode surface plasma, and are accelerated in two stages. The electron energy-spread is reduced sufficiently for an FEM operation in the microwave regime. A 14 keV, 1-2 A e-beam is obtained in a 0.1-2.1 mu s pulse width. The pulse repetition frequency attains 3.1 MHz in approx 50% duty-cycle. This gun is implemented in an FEM oscillator experiment operating around 3 GHz. The paper presents experimental results and discusses the applicability of ferroelectric guns in free-electron laser devices.

  2. Glue Guns: Aiming for Safety

    Science.gov (United States)

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  3. Commentary: evidence to guide gun violence prevention in America.

    Science.gov (United States)

    Webster, Daniel W

    2015-03-18

    Gun violence is a major threat to the public's health and safety in the United States. The articles in this volume's symposium on gun violence reveal the scope of the problem and new trends in mortality rates from gunfire. Leading scholars synthesize research evidence that demonstrates the ability of numerous policies and programs-each consistent with lessons learned from successful efforts to combat public health problems-to prevent gun violence. Each approach presents challenges to successful implementation. Future research should inform efforts to assess which approaches are most effective and how to implement evidence-based interventions most effectively.

  4. A simple concept for covering pressure sores: wound edge-based propeller perforator flap.

    Science.gov (United States)

    Kelahmetoglu, Osman; Van Landuyt, Koenraad; Yagmur, Caglayan; Sommeling, Casper E; Keles, Musa K; Tayfur, Volkan; Simsek, Tekin; Demirtas, Yener; Guneren, Ethem

    2017-12-01

    We present a new surgical modification to allow propeller perforator flaps to cover pressure sores at various locations. We used a propeller perforator flap concept based on the detection of newly formed perforator vessels located 1 cm from the wound margin and stimulated by the chronic inflammation process. Between January 2009 and January 2017, 33 wound edge-based propeller perforator flaps were used to cover pressure sores at various locations in 28 patients. In four cases more than one flap was used on the same patient. The patients comprised 18 males and 10 females with a mean age of 41·25 (range, 16-70) years. All patients underwent follow-up for 0-12 months. The mean follow-up duration was 5·03 months. Venous congestion was observed in three flaps that were rotated by 180° (9·1%). However, there was a significant difference between flaps rotated by 90° and 180° according to the complication rate (P = 0·034). Out of 33 flaps, 29 flaps healed uneventfully. Patients were able to sit and lie on their flaps three weeks after surgery. In our study, we were able to obtain satisfying final results using these novel flaps. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. The Development of the Linac Coherent Light Source RF Gun

    International Nuclear Information System (INIS)

    Dowell, D

    2008-01-01

    The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL) requiring extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new type of light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. Therefore a new RF gun or at least the modification of an existing gun was necessary. The parameters listed in Table 1 illustrate the unique characteristics of LCLS which drive the requirements for the electron gun as given in Table 2. The gun beam quality needs to accommodate emittance growth as the beam is travels through approximately one kilometer of linac and two bunch compressors before reaching the undulator. These beam requirements were demonstrated during the recent commissioning runs of the LCLS injector and linac [2] due to the successful design, fabrication, testing and operation of the LCLS gun. The goal of this paper is to relate the technical background of how the gun was able to achieve and in some cases exceed these requirements by understanding and correcting the deficiencies of the prototype s-band RF photocathode gun, the BNL/SLAC/UCLA Gun III. This paper begins with a brief history and technical description of Gun III and the Gun Test Facility (GTF) at SLAC, and studies of the gun's RF and emittance compensation solenoid. The work at the GTF identified the gun and solenoid deficiencies, and helped to define the specifications for the LCLS gun. Section 1.1.5 describes the modeling used to compute and correct the gun RF fields and Section 1.1.6 describes the use of these fields in the electron beam simulations. The magnetic design and measurements of

  6. "Is there a gun in the home?" Assessing the risks of gun ownership in older adults.

    Science.gov (United States)

    Pinholt, Ellen M; Mitchell, Joshua D; Butler, Jane H; Kumar, Harjinder

    2014-06-01

    An important ethical and safety concern that geriatricians, primary care providers, and home health professionals need to address is gun ownership by elderly adults. Those aged 65 and older now have the highest rate of gun ownership in America, and they also have a high prevalence of depression and suicide. Dementia can add additional layers of risk. Even older gun owners who are otherwise intellectually intact may benefit from information about gun safety with the increasing numbers of children being cared for by grandparents. Health professionals should ask patients, "Is there a gun in the home?" in the clinic and during home visits. Healthcare professionals must have knowledge and skills to address safe gun ownership in elderly adults. The 5 L's (Locked, Loaded, Little children, feeling Low, Learned owner) will assist professionals in addressing all aspects of safe ownership. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  7. Development of laser heated high current DC electron gun

    International Nuclear Information System (INIS)

    Banerjee, Srutarshi; Bhattacharjee, Dhruva; Kandaswamy, E.; Ghodke, S.R.; Tiwari, Rajnish; Bakhtsingh, R.I.

    2015-01-01

    The paper deals with the development of a Laser heated cathode for Electron Accelerator. The electron gun is meant for Megawatt-class DC Accelerator for Electron Beam Flue Gas Treatment applications. Conventionally, LaB 6 cathode is indirectly heated by tungsten filaments whereas in the newly proposed gun, Laser is utilized for heating. A Nd:YAG Laser is used to heat the LaB 6 cathode to emission temperatures. The characterization of cathode heating at various Laser powers has been carried out. In initial trials, it has been observed that with 125 W of Laser power, the LaB 6 pellet was heated to 1315 ° C. Based on these experimental results, an electron gun rated for 30 kV, 350 mA CW has been designed. The optimization of gun electrode geometry has been done using CST Particle Studio in order to tune the various electron gun parameters. The beam diameter obtained in simulation is 8 mm at 100 mm from the LaB 6 cathode. The perveance obtained is 7.1 x 10 -8 A/V 3/2 . The Laser heated cathode has the advantages of eliminating the magnetic field effects of filament on the electron beam, electrical isolation needed for gun filament power supplies and better electron beam emittances. (author)

  8. A high-gradient high-duty-factor Rf photo-cathode electron gun

    International Nuclear Information System (INIS)

    Rimmer, Robert A.; Hartman, Neal; Lidia, Steven M.; Wang, Shaoheng

    2002-01-01

    We describe the analysis and preliminary design of a high-gradient, high-duty factor RF photocathode gun. The gun is designed to operate at high repetition rate or CW, with high gradient on the cathode surface to minimize emittance growth due to space charge forces at high bunch charge. The gun may also be operated in a solenoidal magnetic field for emittance compensation. The design is intended for use in short-pulse, high-charge, and high-repetition rate applications such as linac based X-ray sources. We present and compare the results of gun simulations using different codes, as well as RF and thermal analysis of the structure

  9. A high-gradient high-duty-factor RF photo-cathode electron gun

    International Nuclear Information System (INIS)

    Rimmer, Robert; Hartman, N.; Lidia, S.; Wang, S.H.

    2002-01-01

    We describe the analysis and preliminary design of a high-gradient, high-duty factor RF photocathode gun. The gun is designed to operate at high repetition rate or CW, with high gradient on the cathode surface to minimize emittance growth due to space charge forces at high bunch charge. The gun may also be operated in a solenoidal magnetic field for emittance compensation. The design is intended for use in short-pulse, high-charge, and high-repetition rate applications such as linac based X-ray sources. We present and compare the results of gun simulations using different codes, as well as RF and thermal analysis of the structure

  10. A theoretical study of the relaxation of a phenyl group chemisorbed to an RDX freestanding thin film

    Energy Technology Data Exchange (ETDEWEB)

    Pereverzev, Andrey, E-mail: pereverzeva@missouri.edu; Sewell, Thomas D., E-mail: sewellt@missouri.edu [Department of Chemistry, University of Missouri-Columbia, Columbia, Missouri 65211-7600 (United States)

    2016-08-07

    Energy relaxation from an excited phenyl group chemisorbed to the surface of a crystalline thin film of α-1,3,5-trinitro-1,3,5-triazacyclohexane (α-RDX) at 298 K and 1 atm is simulated using molecular dynamics. Two schemes are used to excite the phenyl group. In the first scheme, the excitation energy is added instantaneously as kinetic energy by rescaling momenta of the 11 atoms in the phenyl group. In the second scheme, the phenyl group is equilibrated at a higher temperature in the presence of static RDX geometries representative of the 298 K thin film. An analytical model based on ballistic phonon transport that requires only the harmonic part of the total Hamiltonian and includes no adjustable parameters is shown to predict, essentially quantitatively, the short-time dynamics of the kinetic energy relaxation (∼200 fs). The dynamics of the phenyl group for times longer than about 6 ps follows exponential decay and agrees qualitatively with the dynamics described by a master equation. Long-time heat propagation within the bulk of the crystal film is consistent with the heat equation.

  11. Delayed myelosuppression with acute exposure to hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and environmental degradation product hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX) in rats

    Energy Technology Data Exchange (ETDEWEB)

    Jaligama, Sridhar; Kale, Vijay M.; Wilbanks, Mitchell S. [Department of Toxicology, College of Pharmacy, University of Louisiana at Monroe, Monroe, LA 71209 (United States); Perkins, Edward J. [US Army Engineer Research and Development Center, Vicksburg, MS 39180 (United States); Meyer, Sharon A., E-mail: meyer@ulm.edu [Department of Toxicology, College of Pharmacy, University of Louisiana at Monroe, Monroe, LA 71209 (United States)

    2013-02-01

    Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), a widely used munitions compound, and hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX), its N-nitroso product of anaerobic microbial nitroreduction, are contaminants of military sites. Previous studies have shown MNX to be the most acutely toxic among the nitroreduced degradation products of RDX and to cause mild anemia at high dose. The present study compares hematotoxicity with acute oral exposure to MNX with parent RDX. Both RDX and MNX caused a modest decrease in blood hemoglobin and ∼ 50% loss of granulocytes (NOAELs = 47 mg/kg) in female Sprague–Dawley rats observed 14 days post-exposure. We explored the possibility that blood cell loss observed after 14 days was delayed in onset because of toxicity to bone marrow (BM) progenitors. RDX and MNX decreased granulocyte/macrophage-colony forming cells (GM-CFCs) at 14, but not 7, days (NOAELs = 24 mg/kg). The earliest observed time at which MNX decreased GM-CFCs was 10 days post-exposure. RDX and MNX likewise decreased BM burst-forming units-erythroid (BFU-Es) at 14, but not 7, days. Granulocyte–erythrocyte–monocyte–megakaryocyte (GEMM)-CFCs were unaffected by RDX and MNX at 7 days suggesting precursor depletion did not account for GM-CFC and BFU-E loss. MNX added to the culture media was without effect on GM-CFC formation indicating no direct inhibition. Flow cytometry showed no differential loss of BM multilineage progenitors (Thy1.1{sup +}) or erythroid (CD71{sup +}) precursors with MNX suggesting myeloid and erythroid lineages were comparably affected. Collectively, these data indicate that acute exposure to both RDX and MNX caused delayed suppression of myelo- and erythropoiesis with subsequent decrease of peripheral granulocytes and erythrocytes. Highlights: ► Acute oral exposure to munitions RDX causes myelosuppression. ► Environmental degradation product MNX is comparable in effect. ► RDX and MNX are cytotoxic to both myeloid and erythroid

  12. Instantaneous current and field structure of a gun-driven spheromak for two gun polarities

    International Nuclear Information System (INIS)

    Woodruff, S; Nagata, M

    2002-01-01

    The instantaneous plasma structure of the SPHEX spheromak is determined here by numerically processing data from insertable Rogowski and magnetic field probes. Data is presented and compared for two modes of gun operation: with the central electrode biased positively and negatively. It is found that while the mean-, or even instantaneous-, field structure would give the impression of a roughly axisymmetric spheromak, the instantaneous current structure does not. Hundred per cent variations in J measured at the magnetic axis can be explained by the rotation of a current filament that has a width equal to half of the radius of the flux-conserving first wall. In positive gun operation, current leaves the filament in the confinement region leading to high wall current there. In negative gun operation, wall current remains low as all injected current returns to the gun through the plasma. The plasma, in either instance, is strongly asymmetric. We discuss evidence for the existence of the current filament in other gun-driven spheromaks and coaxial plasma thrusters

  13. Heavy duty plasma spray gun

    International Nuclear Information System (INIS)

    Irons, G.C.; Klein, J.F.; Lander, R.D.; Thompson, H.C.; Trapani, R.D.

    1984-01-01

    A heavy duty plasma spray gun for extended industrial service is disclosed. The gun includes a gas distribution member made of a material having a coefficient of expansion different from that of the parts surrounding it. The gas distribution member is forcibly urged by a resilient member such as a coiled spring against a seal so as to assure the plasma gas is introduced into the gun arc in a manner only defined by the gas distribution member. The gun has liquid cooling for the nozzle (anode) and the cathode. Double seals are provided between the coolant and the arc region and a vent is provided between the seals which provides an indication when a seal has failed. Some parts of the gun are electrically isolated from others by an intermediate member which is formed as a sandwich of two rigid metal face pieces and an insulator disposed between them. The metal face pieces provide a rigid body to attach the remaining parts in proper alignment therewith

  14. 77 FR 37834 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Science.gov (United States)

    2012-06-25

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use With Caps AGENCY: Consumer Product Safety Commission. ACTION: Notice of proposed rulemaking. SUMMARY... compliance than our existing regulations pertaining to caps intended for use with toy guns and toy guns not...

  15. Theoretical investigation of a travelling-wave rf gun

    International Nuclear Information System (INIS)

    Gao, J.

    1991-12-01

    A travelling-wave type rf gun (TW gun) is investigated theoretically. Analytical formulae concerning energy gain, energy spread, and transverse emittance are derived. After showing the corresponding formulae for the standing-wave rf gun (SW gun), comparisons are made between the two types of rf gun. Finally, some numerical results are calculated to demonstrate further the behaviours of the TW gun, and to compare with those from analytical formulae. (author) 11 refs.; 27 figs

  16. One nanosecond pulsed electron gun systems

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1979-02-01

    At SLAC there has been a continuous need for the injection of very short bunches of electrons into the accelerator. Several time-of-flight experiments have used bursts of short pulses during a normal 1.6 micro-second rf acceleration period. Single bunch beam loading experiments made use of a short pulse injection system which included high power transverse beam chopping equipment. Until the equipment described in this paper came on line, the basic grid-controlled gun pulse was limited to a rise time of 7 nanoseconds and a pulse width of 10 nanoseconds. The system described here has a grid-controlled rise time of less than 500 pico-seconds, and a minimum pulse width of less than 1 nanosecond. Pulse burst repetition rate has been demonstrated above 20 MHz during a 1.6 microsecond rf accelerating period. The order-of-magnitude increase in gun grid switching speed comes from a new gun design which minimizes lead inductance and stray capacitance, and also increases gun grid transconductance. These gun improvements coupled with a newly designed fast pulser mounted directly within the gun envelope make possible subnanosecond pulsing of the gun

  17. Design and development of a pierce electron gun

    International Nuclear Information System (INIS)

    Bhattacharjee, D.; Tiwari, R.; Nayak, B.; Tillu, A.R.; Jayaprakash, D.; Mishra, R.L.; Mittal, K.C.; Chakravarthy, D.P.; Gantayet, L.M.

    2011-01-01

    An electron gun is designed and developed using the Pierce configuration for the focusing electrode. Simulations were carried out using CST Particle Studio. The Gun is a thermionic type electron gun with indirect heating of the LaB6 cathode. The gun is capable of delivering a beam current of 500 mA at 50 kV with a beam size of less than 3.5 mm. It was tested on the gun test bench. This paper presents the gun design, particle simulations study, testing of the gun on test bench and integration with the ECIL 9 MeV linac. (author)

  18. Electron gun for the Fel Clio

    International Nuclear Information System (INIS)

    Chaput, R.

    1990-01-01

    A triode electron gun has been developed and manufactured at LURE (Laboratoire pour l'Utilisation du Rayonnement Electromagnetique) and LAL (Laboratoire de l'Accelerateur Lineaire) for the free electron laser CLIO 1 (Collaboration pour un laser a electrons libres dans l'infrarouge a Orsay) now under construction: this gun involves a grid-cathode assembly manufactured by EIMAC, currently used in the SLAC gun family. For the FEL requirements, the gun must be able to yield a train of short pulses at accuracy frequency or a continuous pulse. Driving together the cathode and the grid the gun produces a continous beam of 12 μs or a pulsed beam of very short pulse of 1 ns at 250 MHz, 125 MHz, 62.5 MHz or 31.25 MHz. The performances of the gun has been tested on a testing bench. A peak current of 1 Amp. for 1 ns width at any frequencies was achieved at an injection voltage of 90 kV

  19. Optimizing SRF Gun Cavity Profiles in a Genetic Algorithm Framework

    International Nuclear Information System (INIS)

    Hofler, Alicia; Evtushenko, Pavel; Marhauser, Frank

    2009-01-01

    Automation of DC photoinjector designs using a genetic algorithm (GA) based optimization is an accepted practice in accelerator physics. Allowing the gun cavity field profile shape to be varied can extend the utility of this optimization methodology to superconducting and normal conducting radio frequency (SRF/RF) gun based injectors. Finding optimal field and cavity geometry configurations can provide guidance for cavity design choices and verify existing designs. We have considered two approaches for varying the electric field profile. The first is to determine the optimal field profile shape that should be used independent of the cavity geometry, and the other is to vary the geometry of the gun cavity structure to produce an optimal field profile. The first method can provide a theoretical optimal and can illuminate where possible gains can be made in field shaping. The second method can produce more realistically achievable designs that can be compared to existing designs. In this paper, we discuss the design and implementation for these two methods for generating field profiles for SRF/RF guns in a GA based injector optimization scheme and provide preliminary results.

  20. Technology of foamed propellants

    Energy Technology Data Exchange (ETDEWEB)

    Boehnlein-Mauss, Jutta; Kroeber, Hartmut [Fraunhofer Institut fuer Chemische Technologie ICT, Pfinztal (Germany)

    2009-06-15

    Foamed propellants are based on crystalline explosives bonded in energetic reaction polymers. Due to their porous structures they are distinguished by high burning rates. Energy content and material characteristics can be varied by using different energetic fillers, energetic polymers and porous structures. Foamed charges can be produced easily by the reaction injection moulding process. For the manufacturing of foamed propellants a semi-continuous remote controlled production plant in pilot scale was set up and a modified reaction injection moulding process was applied. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  1. Sorption kinetics of TNT and RDX in anaerobic freshwater and marine sediments: Batch studies.

    Science.gov (United States)

    Ariyarathna, Thivanka; Vlahos, Penny; Tobias, Craig; Smith, Richard

    2016-01-01

    Examination of the partitioning of explosives onto sediment in marine environments is critical to predict the toxicological impacts of worldwide explosive-contaminated sites adjacent to estuaries, wetlands, and the coastal ocean. Marine sediments have been identified as sites of enhanced munitions removal, yet most studies addressing these interactions focus on soils and freshwater sediments. The present study measured the kinetics of 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) sorption onto 2 marine sediments of varying grain sizes (silt vs sand) and organic carbon (OC) content. Abiotic sediment sorption tests were performed at 23 °C, 15 °C, and 4 °C by spiking TNT and RDX solutions directly into anaerobic sediment slurries. Marine sediments showed significantly higher compound uptake rates (0.30-0.80 h(-1) ) than freshwater silt (0.0046-0.0065 h(-1) ) for both compounds, probably because of lower compound solubilities and a higher pH in marine systems. Equilibrium partition constants are on the same order of magnitude for marine silt (1.1-2.0 L kg(-1) sediment) and freshwater silt (1.4-3.1 L kg(-1) sediment) but lower for marine sand (0.72-0.92 L kg(-1) sediment). Total organic carbon content in marine sediments varied linearly with equilibrium partition constants for TNT and was moderately linear for RDX. Uptake rates and equilibrium constants of explosives are inversely correlated to temperature regardless of sediment type because of kinetic barriers associated with low temperatures. © 2015 SETAC.

  2. Gas gun dynamics

    International Nuclear Information System (INIS)

    Denny, Mark

    2013-01-01

    The mechanics and thermodynamics of one- and two-stage gas guns are developed. Very high projectile muzzle speed can be obtained by the two-stage version. The physics of simple gas guns, such as air rifles, is accessible to undergraduates and the same level of presentation is used here to understand more complex designs. Numerical solutions to the equations of motion are shown, along with insightful analytic approximations. (paper)

  3. Alignment Fixtures For Vacuum-Plasma-Spray Gun

    Science.gov (United States)

    Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.

    1993-01-01

    Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.

  4. The effects of use self-propelled rain guns (typhone) in irrigation of corn (Zea mays L.)

    OpenAIRE

    Kresović, Branka; Dragičević, Vesna; Gajić, Boško; Tapanrova, Angelina; Pejić, Borivoje

    2012-01-01

    The aim of this study was to use results of experimental work to analyse effects of maize irrigation and to quantify basic parameters that are included into exploitation costs of a long-ranged self-propelled sprayer, so called typhoon sprinkler. The four-replicate trial was carried out according to a randomised block design in the experimental fields of the Maize Research Institute, Zemun Polje, during the 2002-2008 period. The irrigation was applied in all years but 2004 in which the precipi...

  5. Electron gun

    International Nuclear Information System (INIS)

    Chen, H.-Y.; Hughes, R.H.

    1979-01-01

    The invention described relates to cathode ray tubes, and particularly to color picture tubes of the type useful in home television receivers and therefore to electron guns. The invention is especially applicable to self-converging tube-yoke combinations with shadow mask tubes of the type having plural-beam in-line guns disposed in a horizontal plane, an apertured mask with vertically oriented slit-shaped apertures, and a screen with vertically oriented phosphor stripes. The invention is not, however, limited to use in such tubes and may in fact be used, e.g., in dot-type shadow mask tubes and index-type tubes. (Auth.)

  6. Results of Propellant Mixing Variable Study Using Precise Pressure-Based Burn Rate Calculations

    Science.gov (United States)

    Stefanski, Philip L.

    2014-01-01

    A designed experiment was conducted in which three mix processing variables (pre-curative addition mix temperature, pre-curative addition mixing time, and mixer speed) were varied to estimate their effects on within-mix propellant burn rate variability. The chosen discriminator for the experiment was the 2-inch diameter by 4-inch long (2x4) Center-Perforated (CP) ballistic evaluation motor. Motor nozzle throat diameters were sized to produce a common targeted chamber pressure. Initial data analysis did not show a statistically significant effect. Because propellant burn rate must be directly related to chamber pressure, a method was developed that showed statistically significant effects on chamber pressure (either maximum or average) by adjustments to the process settings. Burn rates were calculated from chamber pressures and these were then normalized to a common pressure for comparative purposes. The pressure-based method of burn rate determination showed significant reduction in error when compared to results obtained from the Brooks' modification of the propellant web-bisector burn rate determination method. Analysis of effects using burn rates calculated by the pressure-based method showed a significant correlation of within-mix burn rate dispersion to mixing duration and the quadratic of mixing duration. The findings were confirmed in a series of mixes that examined the effects of mixing time on burn rate variation, which yielded the same results.

  7. A gun recoil system employing a magnetorheological fluid damper

    International Nuclear Information System (INIS)

    Li, Z C; Wang, J

    2012-01-01

    This research aims to design and control a full scale gun recoil buffering system which works under real firing impact loading conditions. A conventional gun recoil absorber is replaced with a controllable magnetorheological (MR) fluid damper. Through dynamic analysis of the gun recoil system, a theoretical model for optimal design and control of the MR fluid damper for impact loadings is derived. The optimal displacement, velocity and optimal design rules are obtained. By applying the optimal design theory to protect against impact loadings, an MR fluid damper for a full scale gun recoil system is designed and manufactured. An experimental study is carried out on a firing test rig which consists of a 30 mm caliber, multi-action automatic gun with an MR damper mounted to the fixed base through a sliding guide. Experimental buffering results under passive control and optimal control are obtained. By comparison, optimal control is better than passive control, because it produces smaller variation in the recoil force while achieving less displacement of the recoil body. The optimal control strategy presented in this paper is open-loop with no feedback system needed. This means that the control process is sensor-free. This is a great benefit for a buffering system under impact loading, especially for a gun recoil system which usually works in a harsh environment. (paper)

  8. Operation of the APS rf gun

    International Nuclear Information System (INIS)

    Lewellen, J. W.

    1998-01-01

    The Advanced Photon Source (APS) has a thermionic-cathode rf gun system capable of providing beam to the APS linac. The gun system consists of a 1.6-cell thermionic-cathode rf gun, a fast kicker for beam current control, and an alpha magnet for bunch compression and injection into the APS linac line. This system is intended for use both as an injector for positron creation, and as a first beam source for the Low-Energy Undulator Test Line (LEUTL) project [1]. The first measured performance characteristics of the gun are presented.

  9. KAPPEL Propeller. Development of a Marine Propeller with Non-planar Lifting Surfaces

    DEFF Research Database (Denmark)

    Kappel, J.; Andersen, Poul

    2002-01-01

    The principle of non-planar lifting surfaces is applied to the design of modern aircraft wings to obtain better lift to drag ratios. Whereas a pronounced fin or "winglet" at the wingtip has been developed for aircraft, the application of the non-planar principle to marine propellers, dealt...... with in this paper, has led to the KAPPEL propeller with blades curved towards the suction side integrating the fin or winglet into the propeller blade. The combined theoretical, experimental and practical approach to develop and design marine propellers with non-planar lifting surfaces has resulted in propellers...

  10. The elbe accelerator facility starts operation with the superconducting rf gun

    CERN Document Server

    Xiang, R; Buettig, H; Janssen, D; Justus, M; Lehnert, U; Michel, P; Murcek, P; Schneider, C; Schurig, R; Staufenbiel, F; Teichert, J; Kamps, T; Rudolph, J; Schenk, M; Klemz, G; Will, I

    2010-01-01

    As the first superconducting rf photo-injector (SRF gun) in practice, the FZD 3+1/2 cell SRF gun is successfully connected to the superconducting linac ELBE. This setting will improve the beam quality for ELBE users. It is the first example for an accelerator facility fully based on superconducting RF technology. For high average power FEL and ERL sources, the combination of SRF linac and SRF gun provides a new chance to produce beams of high average current and low emittance with relative low power consumption. The main parameters achieved from the present SRF gun are the final electron energy of 3 MeV, 16 μA average current, and rms transverse normalized emittances of 3 mm mrad at 77 pC bunch charge. A modified 3+1/2 cell niobium cavity has been fabricated and tested, which will increase the rf gradient in the gun and thus better the beam parameters further. In this paper the status of the integration of the SRF gun with the ELBE linac will be presented, and the latest results of the beam experiments will ...

  11. High Impulse Nanoparticulate-Based Gel Propellants, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposed Small Business Innovative Research (SBIR) Phase I addresses the development of advanced gel propellants and determination of their suitability for...

  12. Middle Ground on Gun Control

    Science.gov (United States)

    2016-12-01

    34 Australian Institute of Criminology, July 7, 2015, http://www.aic.gov.au/ statistics /homicide/weapon.html. 0 100 200 300 400 500 600 700 Total Gun...firearms is not the business of a single Australian , so it is immeasurably easier for politicians to categorically ban types of guns because there is...not an Australian version of Smith and Wesson that is going to be put out of business . Additionally, because all of the guns in Australia are

  13. PIV-based load determination in aircraft propellers

    NARCIS (Netherlands)

    Ragni, D.

    2012-01-01

    The thesis describes the application of particle image velocimetry (PIV) to study the aerodynamic loads of airfoils and aircraft propellers. The experimental work focuses on the development of a measurement procedure to infer the pressure of the flow field from the velocity distribution obtained by

  14. Interpreting the empirical evidence on illegal gun market dynamics.

    Science.gov (United States)

    Braga, Anthony A; Wintemute, Garen J; Pierce, Glenn L; Cook, Philip J; Ridgeway, Greg

    2012-10-01

    Thousands of Americans are killed by gunfire each year, and hundreds of thousands more are injured or threatened with guns in robberies and assaults. The burden of gun violence in urban areas is particularly high. Critics suggest that the results of firearm trace data and gun trafficking investigation studies cannot be used to understand the illegal supply of guns to criminals and, therefore, that regulatory and enforcement efforts designed to disrupt illegal firearms markets are futile in addressing criminal access to firearms. In this paper, we present new data to address three key arguments used by skeptics to undermine research on illegal gun market dynamics. We find that criminals rely upon a diverse set of illegal diversion pathways to acquire guns, gun traffickers usually divert small numbers of guns, newer guns are diverted through close-to-retail diversions from legal firearms commerce, and that a diverse set of gun trafficking indicators are needed to identify and shut down gun trafficking pathways.

  15. Experimental studies of coaxial plasma gun current

    International Nuclear Information System (INIS)

    Price, D.W.

    1988-01-01

    In this investigation of a coaxial plasma gun, plasma sheath currents and related behavior are examined. Plasma behavior in the gun affects gun characteristics. Plasma gun applications are determined by the plasma behavior. The AFWL PUFF capacitor bank (72 μF, 29 nH, 120 kV) drives the plasma gun using a deuterium fill gas. The gas breakdown site is isolated from the dielectric/vacuum interface in the AFWL system. Two gas values deliver gas in the system. The first delivers gas from the gun breech and the second optional valve delivers gas to the gun muzzle. Currents and voltages are measured by Rogowski coils, B probes and capacitive voltage probes. A O-D slug model is used to predict the current, inductance, gun voltage and plasma sheath velocity. The slug model assumes the sheath transits the gun with all mass in the sheath. In the snowplow mode, the plasma sheath is thin with a sharp current rise and drop. Our system operated in a transition mode between the snowplow and deflagration modes with early snowplow behavior and late deflagration behavior. Neutrons are produced in a plasma pinch at the gun muzzle, indicating snowplow behavior. The slug theory models overall gun behavior to experimental accuracy. Experimental results are compared to four theories for plasma sheath velocities: the Alfven collisionally limited model, the Rosenbluth model, the Fishbine saturated model and a single particle drift model. Experimental velocities vary from 10 5 to 10 6 m/s. Only the single particle drift and the slug model calculations are of the right magnitude (8 x 10 5 m/s). The Fishbine and the Rosenbluth models predict slower velocities (2 x 10 5 m/s). The Alfven model is not applicable to this system

  16. Gun Safety (For Parents)

    Science.gov (United States)

    ... from the home of a relative or friend. Teens should never be able to get to a gun and bullets without an adult being there. People of any age who are depressed are at increased risk of suicide. If someone in the family has depression, or has had thoughts of suicide, all guns ...

  17. Remotely controlled spray gun

    Science.gov (United States)

    Cunningham, William C. (Inventor)

    1987-01-01

    A remotely controlled spray gun is described in which a nozzle and orifice plate are held in precise axial alignment by an alignment member, which in turn is held in alignment with the general outlet of the spray gun by insert. By this arrangement, the precise repeatability of spray patterns is insured.

  18. American State Gun Law Strength and State Resident Differences in Neuroticism Levels

    Directory of Open Access Journals (Sweden)

    Stewart J. H. McCann

    2016-04-01

    Full Text Available Relations between state gun law strength and state-aggregated levels of Republican leaning, gun ownership, and resident Big Five neuroticism (based on 619,397 residents nationally were determined in a state-level analysis of the 50 American states using multiple regression strategies with state socioeconomic status, white population percent, and urban population percent statistically controlled. In a standard hierarchical model with state gun law strength as the criterion, the three demographic variables accounted for 44.4% of the variance and the Big Five accounted for another 21.9%. When the Big Five entered stepwise after the demographics, neuroticism was the sole significant personality predictor, accounting for another 13.4% of the variance. Greater state gun law strength was associated with higher state resident neuroticism. Further hierarchical regression analyses showed that state Republican leaning and gun ownership could account separately and jointly for significant variance in state gun law strength but not with state resident neuroticism controlled.

  19. Measurements of Transverse Emittance for RF Photocathode Gun at the PAL

    CERN Document Server

    Park Jang Ho; Park, Sung-Ju; Soo Ko In; Wang, Xijie; Woon Parc, Yong; Xiang, Dao

    2005-01-01

    A BNL GUN-IV type RF photo-cathode gun is under fabrication for use in the FIR (Far Infra-Red) facility being built at the Pohang Accelerator Laboratory (PAL). Performance test of the gun will include the measurement of transverse emittance profile along the longitudinal direction. Successful measurement of the emittance profile will provide powerful tool for the commissioning of the 4GLS (4th generation light source) injectors based on the emittance compensation principle. We are going to achieve this withthe use of pepper-pot based emittance meters that can be moved along the longitudinal direction. In this article, we present design considerations on the emittance meter with the resolution of 1 mm mrad.

  20. Study of the hollow cathode plasma electron-gun

    International Nuclear Information System (INIS)

    Zhang Yonghui; Jiang Jinsheng; Chang Anbi

    2003-01-01

    For developing a novel high-current, long pulse width electron source, the theoretics and mechanism of the hollow cathode plasma electron-gun are analyzed in detail in this paper, the structure and the physical process of hollow cathode plasma electron-gun are also studied. This gun overcomes the limitations of most high-power microwave tubes, which employ either thermionic cathodes that produce low current-density beams because of the limitation of the space charge, or field-emission cathodes that offer high current density but provide only short pulse width because of plasma closure of the accelerating gap. In the theories studying on hollow cathode plasma electron-gun, the characteristic of the hollow-cathode discharge is introduced, the action during the forming of plasma of the stimulating electrode and the modulating anode are discussed, the movement of electrons and ions and the primary parameters are analyzed, and the formulas of the electric field, beam current density and the stabilization conditions of the beam current are also presented in this paper. The numerical simulation is carried out based on Poisson's equation, and the equations of current continuity and movement. And the optimized result is reported. On this basis, we have designed a hollow-cathode-plasma electron-gun, whose output pulse current is 2 kA, and pulse width is 1 microsecond

  1. Conceptual Design for CLIC Gun Pulser

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Tao [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-01-08

    The Compact Linear Collider (CLIC) is a proposed future electron-positron collider, designed to perform collisions at energies from 0.5 to 5 TeV, with a nominal design optimized for 3 TeV (Dannheim, 2012). The Drive Beam Accelerator consists of a thermionic DC gun, bunching section and an accelerating section. The thermionic gun needs deliver a long (~143us) pulse of current into the buncher. A pulser is needed to drive grid of the gun to generate a stable current output. This report explores the requirements of the gun pulser and potential solutions to regulate grid current.

  2. Results of the SLAC LCLS Gun High-Power RF Tests

    International Nuclear Information System (INIS)

    Dowell, D.H.; Jongewaard, E.; Limborg-Deprey, C.; Schmerge, J.F.; Li, Z.; Xiao, L.; Wang, J.; Lewandowski, J.; Vlieks, A.

    2007-01-01

    The beam quality and operational requirements for the Linac Coherent Light Source (LCLS) currently being constructed at SLAC are exceptional, requiring the design of a new RF photocathode gun for the electron source. Based on operational experience at SLAC's GTF and SDL and ATF at BNL as well as other laboratories, the 1.6cell s-band (2856MHz) gun was chosen to be the best electron source for the LCLS, however a significant redesign was necessary to achieve the challenging parameters. Detailed 3-D analysis and design was used to produce near-perfect rotationally symmetric rf fields to achieve the emittance requirement. In addition, the thermo-mechanical design allows the gun to operate at 120Hz and a 140MV/m cathode field, or to an average power dissipation of 4kW. Both average and pulsed heating issues are addressed in the LCLS gun design. The first LCLS gun is now fabricated and has been operated with high-power RF. The results of these high-power tests are presented and discussed

  3. Fueling by coaxial plasma guns

    International Nuclear Information System (INIS)

    Marshall, J.

    1978-01-01

    The operating principles of pulsed coaxial guns are reviewed. Some problems involved with the injection of plasma beams from these guns into containment fields are described. The injection during reactor operating conditions is then discussed

  4. Hull-Propeller Interaction and Its Effect on Propeller Cavitation

    DEFF Research Database (Denmark)

    Regener, Pelle Bo

    In order to predict the required propulsion power for a ship reliably and accurately, it is not sufficient to only evaluate the resistance of the hull and the propeller performance in open water alone. Interaction effects between hull and propeller can even be a decisive factor in ship powering...... prediction and design optimization. The hull-propeller interaction coefficients of effective wake fraction, thrust deduction factor, and relative rotative efficiency are traditionally determined by model tests. Self-propulsion model tests consistently show an increase in effective wake fractions when using...... velocities. This offers an opportunity for additional insight into hull-propeller interaction and the propeller’s actual operating condition behind the ship, as the actual (effective) inflow is computed. Self-propulsion simulations at model and full scale were carried out for a bulk carrier, once...

  5. Iridium-catalyst-based autonomous bubble-propelled graphene micromotors with ultralow catalyst loading.

    Science.gov (United States)

    Wang, Hong; Sofer, Zdeněk; Eng, Alex Yong Sheng; Pumera, Martin

    2014-11-10

    A novel concept of an iridium-based bubble-propelled Janus-particle-type graphene micromotor with very high surface area and with very low catalyst loading is described. The low loading of Ir catalyst (0.54 at %) allows for fast motion of graphene microparticles with high surface area of 316.2 m(2)  g(-1). The micromotor was prepared with a simple and scalable method by thermal exfoliation of iridium-doped graphite oxide precursor composite in hydrogen atmosphere. Oxygen bubbles generated from the decomposition of hydrogen peroxide at the iridium catalytic sites provide robust propulsion thrust for the graphene micromotor. The high surface area and low iridium catalyst loading of the bubble-propelled graphene motors offer great possibilities for dramatically enhanced cargo delivery. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Gun Violence, mental health, and Connecticut physicians.

    Science.gov (United States)

    Dodds, Peter R; Anderson, Caitlyn O; Dodds, Jon H

    2014-01-01

    While there is a public perception that gun violence is associated with mental illness we present evidence that it is a complex public health problem which defies simple characterizations and solutions. Only a small percentage of individuals with mental illness are at risk for extreme violence and they account for only a small percentage of gun-related homicides. Individuals who are at risk for gun violence are difficult to identify and successfully treat. The incidence, and perhaps the demographics, of gun violence vary substantially from state to state. We make a case for Connecticut physicians to study gun violence at the state level. We recommend that Connecticut physicians promote and expand upon the American Academy of Pediatrics' recommendation for creating a "safe home environment. "We suggest that guns be secured in all homes in which there are children. In addition we suggest that guns be voluntarily removed from homes in which there are individuals with a history of violence, threats of violence, depression, drug and/or alcohol abuse, and individuals with major mental illnesses who are not cooperating with therapy.

  7. Electric rail gun application to space propulsion

    International Nuclear Information System (INIS)

    Barber, J.P.

    1979-01-01

    The paper examines the possibility of using the DC electric gun principles as a space vehicle propulsion system, capable of producing intermediate thrust levels. The application of an electromagnetic launch technique, called the DC electric rail gun, to the space propulsion concept of O'Neill, is examined. It is determined that the DC electric rail gun offers very high projectile accelerations and a very significant potential for reducing the size and mass of a reaction motor for space application. A detailed description of rail gun principles is given and some simple expressions for the accelerating force, gun impedance, power supply requirements, and system performance are discussed

  8. Cost and Performance Report: Bioaugmentation for Aerobic Bioremediation of RDX-Contaminated Groundwater

    Science.gov (United States)

    2015-09-01

    costs were also included. The addition of two extraction wells would not require an upgrade of the current granular activated carbon (GAC) treatment...transport properties, and RDX-degrading activity in UMCD aquifer material and groundwater. Phase II included a field-scale cell transport test conducted ...Accordingly, users may plan to conduct a field tracer test to confirm hydraulic connectivity between the injection and downgradient monitoring

  9. Association Between Substance Use and Gun-Related Behaviors.

    Science.gov (United States)

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Anatomical study of the popliteal artery perforator-based propeller flap and its clinical application.

    Science.gov (United States)

    Onishi, Tadanobu; Shimizu, Takamasa; Omokawa, Shohei; Sananpanich, Kanit; Kido, Akira; Mahakkanukrauh, Pasuk; Tanaka, Yasuhito

    2018-05-30

    There is lack of anatomical information regarding cutaneous perforator of the popliteal artery and its connections with the descending branch of the inferior gluteal and profunda femoris arteries. We aimed to evaluate the anatomical basis of popliteal artery perforator-based propeller flap from the posterior thigh region and to demonstrate our experience utilizing this flap. Ten fresh cadaveric lower extremities were dissected following injection of a silicone compound into the femoral artery. We investigated the number, location, length, and diameter of cutaneous perforators of the popliteal artery. Based on the results, we treated three cases with a large soft tissue defect around the knee using popliteal artery perforator-based propeller flap. We found a mean of 1.9 cutaneous perforators arising from the popliteal artery with a mean pedicle length of 6 cm and a mean arterial internal diameter of 0.9 mm, which were located at an average of 4 cm proximal to the bicondylar line. The most distal perforator consistently arose along the small saphenous vein and connected proximally with concomitant artery of the posterior femoral cutaneous nerve, forming a connection with perforating arteries of the profunda femoris artery. A mean of 4.5 cutaneous perforators branched from the arterial connection sites. All clinical cases healed without any complications. The popliteal artery perforator-based propeller flap is reliable for reconstruction of soft tissue defects around the knee. The flap should include the deep fascia and concomitant artery along with the posterior femoral cutaneous nerve for maintaining the blood supply.

  11. Brief use of a specific gun in a violent game does not affect attitudes towards that gun.

    Science.gov (United States)

    Hilgard, Joseph; Engelhardt, Christopher R; Bartholow, Bruce D

    2016-11-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates ( N  = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures.

  12. Brief use of a specific gun in a violent game does not affect attitudes towards that gun

    Science.gov (United States)

    Engelhardt, Christopher R.; Bartholow, Bruce D.

    2016-01-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates (N = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures. PMID:28018611

  13. Nail gun injuries among construction workers.

    Science.gov (United States)

    Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas

    2003-05-01

    Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data

  14. Use of coaxial plasma guns to start up field-reversed-mirror reactors

    International Nuclear Information System (INIS)

    Smith, A.C. Jr.; Carlson, G.A.; Eddleman, J.L.; Hartman, C.W.; Neef, W.S. Jr.

    1980-01-01

    Application of a magnetized coaxial plasma gun for start-up of a field-reversed-mirror reactor is considered. The design is based on preliminary scaling laws and is compared to the design of the start-up gun used in the Beta II experiment

  15. Rail gun powered by an integral explosive generator

    International Nuclear Information System (INIS)

    Peterson, D.R.; Fowler, C.M.

    1979-01-01

    We propose the use of a rail gun powered by an explosive magnetic flux compression generator built into the rail gun itself in which the rails of the gun are driven together behind the projectile by explosives. The magnetic field established between the rails by an initial current supplied by an external source at the breech of the gun is trapped and compressed by the collapsing rails to accelerate the projectile down the bore of the gun

  16. Environmental Toxicity of the Explosives RDX and TNT in Soil to the Soil Invertebrate Folsomia candida

    National Research Council Canada - National Science Library

    Phillips, Carlton T; Checkai, Ronald T; Kuperman, Roman G; Simini, Michael; Kolakowski, Jan E; Kurnas, Carl W

    2004-01-01

    ...; medium for RCL and KCL; and relatively low or WCL soil. We investigated whether soil type affects the toxicity of RDX or TNT in soil to Collembola by adapting a standardized Folsomia reproduction test (ISO 11267:1998...

  17. A novel electron gun for inline MRI-linac configurations

    International Nuclear Information System (INIS)

    Constantin, Dragoş E.; Fahrig, Rebecca; Holloway, Lois; Keall, Paul J.

    2014-01-01

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T

  18. A Simple Method for High-Lift Propeller Conceptual Design

    Science.gov (United States)

    Patterson, Michael; Borer, Nick; German, Brian

    2016-01-01

    In this paper, we present a simple method for designing propellers that are placed upstream of the leading edge of a wing in order to augment lift. Because the primary purpose of these "high-lift propellers" is to increase lift rather than produce thrust, these props are best viewed as a form of high-lift device; consequently, they should be designed differently than traditional propellers. We present a theory that describes how these props can be designed to provide a relatively uniform axial velocity increase, which is hypothesized to be advantageous for lift augmentation based on a literature survey. Computational modeling indicates that such propellers can generate the same average induced axial velocity while consuming less power and producing less thrust than conventional propeller designs. For an example problem based on specifications for NASA's Scalable Convergent Electric Propulsion Technology and Operations Research (SCEPTOR) flight demonstrator, a propeller designed with the new method requires approximately 15% less power and produces approximately 11% less thrust than one designed for minimum induced loss. Higher-order modeling and/or wind tunnel testing are needed to verify the predicted performance.

  19. Rate control for electron gun evaporation

    International Nuclear Information System (INIS)

    Schellingerhout, A.J.G.; Janocko, M.A.; Klapwijk, T.M.; Mooij, J.E.

    1989-01-01

    Principles for obtaining high-quality rate control for electron gun evaporation are discussed. The design criteria for rate controllers are derived from this analysis. Results are presented which have been obtained with e-guns whose evaporation rate is controlled by a Wehnelt electrode or by sweeping of the electron beam. Further improvements of rate stability can be obtained by improved design of e-guns and power supplies

  20. Self-propelled magnesium based micromotors: synthesis and magnetic steering

    Directory of Open Access Journals (Sweden)

    Jin Dongdong

    2015-01-01

    Full Text Available In this work the magnesium based Janus micromotors were prepared by an asymmetric coating of Co-Au bilayer on the surface of Mg microparticles. The micromotor could efficiently self-propel in phosphate buffer saline (PBS with a highest speed of 221 μm·s−1 without any extra additives through the macrogalvanic corrosion and pitting corrosion mechanism. The influence of pH value of PBS buffer on the motion of micromotor was also investigated. Moreover, we demonstrated that the motion of micromotor could be controlled by an external magnetic field rapidly and accurately, indicating the potential application in biomedicine.

  1. Background Checks for all Gun Buyers and Gun Violence Restraining Orders: State Efforts to Keep Guns from High-Risk Persons.

    Science.gov (United States)

    Vernick, Jon S; Alcorn, Ted; Horwitz, Joshua

    2017-03-01

    There were more than 36,000 firearm-related deaths in the U.S. in 2015. Under federal law, a background check is required only for gun purchases from licensed dealers. Research suggests that some persons prohibited from owning a gun turn to private sellers, including those identified online, to attempt to obtain a firearm. State-level approaches to make it more difficult for high-risk persons to purchase or possess firearms include universal background check (UBC) and gun violence restraining order (GVRO) laws. UBC laws, on the books in 18 states as of the end of 2016, can reduce both homicide and suicide rates. After Colorado adopted a UBC law in 2013, the number of background checks conducted by private sellers for sales occurring at places other than gun shows steadily increased. GVRO laws give law enforcement and families the authority to petition a court to temporarily remove firearms from an individual who presents a danger to himself or others during times of crisis, regardless of whether that person has been diagnosed with a mental illness. California enacted a GVRO law in 2014. Data are emerging to suggest the effectiveness of GVRO-type laws at averting suicides and providing an entryway to services.

  2. State Firearm Laws and Interstate Transfer of Guns in the USA, 2006-2016.

    Science.gov (United States)

    Collins, Tessa; Greenberg, Rachael; Siegel, Michael; Xuan, Ziming; Rothman, Emily F; Cronin, Shea W; Hemenway, David

    2018-06-01

    In a cross-sectional, panel study, we examined the relationship between state firearm laws and the extent of interstate transfer of guns, as measured by the percentage of crime guns recovered in a state and traced to an in-state source (as opposed to guns recovered in a state and traced to an out-of-state source). We used 2006-2016 data on state firearm laws obtained from a search of selected state statutes and 2006-2016 crime gun trace data from the Bureau of Alcohol, Tobacco, Firearms, and Explosives. We examined the relationship between state firearm laws and interstate transfer of guns using annual data from all 50 states during the period 2006-2016 and employing a two-way fixed effects model. The primary outcome variable was the percentage of crime guns recovered in a state that could be traced to an original point of purchase within that state as opposed to another state. The main exposure variables were eight specific state firearm laws pertaining to dealer licensing, sales restrictions, background checks, registration, prohibitors for firearm purchase, and straw purchase of guns. Four laws were independently associated with a significantly lower percentage of in-state guns: a waiting period for handgun purchase, permits required for firearm purchase, prohibition of firearm possession by people convicted of a violent misdemeanor, and a requirement for relinquishment of firearms when a person becomes disqualified from owning them. States with a higher number of gun laws had a lower percentage of traced guns to in-state dealers, with each increase of one in the total number of laws associated with a decrease of 1.6 percentage points in the proportion of recovered guns that were traced to an in-state as opposed to an out-of-state source. Based on an examination of the movement patterns of guns across states, the overall observed pattern of gun flow was out of states with weak gun laws and into states with strong gun laws. These findings indicate that certain

  3. Grip-Pattern Verification for Smart Gun Based on Maximum-Pairwise Comparison and Mean-Template Comparison

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.

    2008-01-01

    In our biometric verification system of a smart gun, the rightful user of a gun is authenticated by grip-pattern recognition. In this work verification will be done using two types of comparison methods, respectively. One is mean-template comparison, where the matching score between a test image and

  4. Self-bunching electron guns

    Science.gov (United States)

    Mako, Frederick M.; Len, L. K.

    1999-05-01

    We report on three electron gun projects that are aimed at power tube and injector applications. The purpose of the work is to develop robust electron guns which produce self-bunched, high-current-density beams. We have demonstrated, in a microwave cavity, self-bunching, cold electron emission, long life, and tolerance to contamination. The cold process is based on secondary electron emission. FMT has studied using simulation codes the resonant bunching process which gives rise to high current densities (0.01-5 kA/cm2), high charge bunches (up to 500 nC/bunch), and short pulses (1-100 ps) for frequencies from 1 to 12 GHz. The beam pulse width is nominally ˜5% of the rf period. The first project is the L-Band Micro-Pulse Gun (MPG). Measurements show ˜40 ps long micro-bunches at ˜20 A/cm2 without contamination due to air exposure. Lifetime testing has been carried out for about 18 months operating at 1.25 GHz for almost 24 hours per day at a repetition rate of 300 Hz and 5 μs-long macro-pulses. Approximately 5.8×1013 micro-bunches or 62,000 coulombs have passed through this gun and it is still working fine. The second project, the S-Band MPG, is now operational. It is functioning at a frequency of 2.85 GHz, a repetition rate of 30 Hz, with a 2 μs-long macro-pulse. It produces about 45 A in the macro-pulse. The third project is a 34.2 GHz frequency-multiplied source driven by an X-Band MPG. A point design was performed at an rf output power of 150 MW at 34.2 GHz. The resulting system efficiency is 53% and the gain is 60 dB. The system efficiency includes the input cavity efficiency, input driver efficiency (a 50 MW klystron at 11.4 GHz), output cavity efficiency, and the post-acceleration efficiency.

  5. Testing a GaAs cathode in SRF gun

    International Nuclear Information System (INIS)

    Wang, E.; Kewisch, J.; Ben-Zvi, I.; Burrill, A.; Rao, T.; Wu, Q.; Holmes, D.

    2011-01-01

    RF electron guns with a strained superlattice GaAs cathode are expected to generate polarized electron beams of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface and lower cathode temperature. We plan to install a bulk GaAs:Cs in a SRF gun to evaluate the performance of both the gun and the cathode in this environment. The status of this project is: In our 1.3 GHz 1/2 cell SRF gun, the vacuum can be maintained at nearly 10 -12 Torr because of cryo-pumping at 2K. With conventional activation of bulk GaAs, we obtained a QE of 10% at 532 nm, with lifetime of more than 3 days in the preparation chamber and have shown that it can survive in transport from the preparation chamber to the gun. The beam line has been assembled and we are exploring the best conditions for baking the cathode under vacuum. We report here the progress of our test of the GaAs cathode in the SRF gun. Future particle accelerators, such as eRHIC and the ILC require high-brightness, high-current polarized electrons. Strained superlattice GaAs:Cs has been shown to be an efficient cathode for producing polarized electrons. Activation of GaAs with Cs,O(F) lowers the electron affinity and makes it energetically possible for all the electrons, excited into the conduction band that drift or diffuse to the emission surface, to escape into the vacuum. Presently, all operating polarized electron sources, such as the CEBAF, are DC guns. In these devices, the excellent ultra-high vacuum extends the lifetime of the cathode. However, the low field gradient on the photocathode's emission surface of the DC guns limits the beam quality. The higher accelerating gradients, possible in the RF guns, generate a far better beam. Until recently, most RF guns operated at room temperature, limiting the vacuum to ∼10 -9 Torr. This destroys the GaAs's NEA surface. The SRF guns combine the excellent vacuum conditions of DC guns and the high accelerating

  6. Extended suicide using an atypical stud gun.

    Science.gov (United States)

    Hagemeier, L; Schyma, C; Madea, B

    2009-08-10

    Suicides with stud guns are uncommon, but are well documented in the literature. On rare occasions, stud guns are also used as a homicide weapon. This case report describes an extended suicide in which a husband killed his wife and their two dogs, which lived on the property. The husband then committed suicide with a shot from the stud gun into his skull. He was a 70-year-old pensioner, a retired butcher, who was found by his son. He was lying in a supine position on a carpet in the living room, with the stud gun stuck in his skull. During autopsy, high concentrations of an antihistamine were found in the blood of each corpse; this drug is used as a soporific. In contrast to the literature, which mainly describes powder deposits due to the use of conventional stud guns, in this case a stud gun was used in which the expanding gases and powder escaped together with the central bolt at the front of the device; powder drains were not involved. Detailed findings of the autopsy are given with reference to this type of stud gun.

  7. Studies of free field and confined explosions of aluminium enriched RDX compositions

    Energy Technology Data Exchange (ETDEWEB)

    Trzcinski, Waldemar A.; Cudzilo, Stanislaw; Paszula, Jozef [Military University of Technology, Kaliskiego 2, 00-908 Warsaw (Poland)

    2007-12-15

    Research on the effect of aluminium contents and its particle size on free field and confined explosions characteristics of RDX-based compositions containing 15-60% aluminium was carried out. Parameters of blast waves produced by charges of the investigated explosives detonating in an open space were measured by the use of piezoelectric gauges. Simultaneously, photodiode set-ups were used to measure light output of the detonating charges. Quasi-static pressure measurements were conducted in steel chambers of 0.15 and 7 m{sup 3} volume filled with air. Moreover, the heat of detonation was measured with a calorimetric set in a 5.6 dm{sup 3} bomb filled with argon. The results of QSP and detonation heat measurements were compared with those obtained from thermochemical calculations. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  8. Ready, Fire, Aim: The College Campus Gun Fight

    Science.gov (United States)

    Birnbaum, Robert

    2013-01-01

    The question of whether guns should be permitted on college and university campuses in the United States reflects the tension between two competing perspectives. America has both a robust gun culture and an equally robust (if less well known) gun-control culture. The gun culture is as American as apple pie: There may be as many as 300 million…

  9. Identification and molecular characterization of the second Chlamydomonas gun4 mutant, gun4-II [v2; ref status: indexed, http://f1000r.es/1id

    Directory of Open Access Journals (Sweden)

    Phillip B Grovenstein

    2013-07-01

    Full Text Available The green micro-alga Chlamydomonas reinhardtii is an elegant model organism to study oxygenic photosynthesis. Chlorophyll (Chl and heme are major tetrapyrroles that play an essential role in photosynthesis and respiration. These tetrapyrroles are synthesized via a common branched pathway that involves mainly enzymes, encoded by nuclear genes. One of the enzymes in the pathway is Mg chelatase (MgChel. MgChel catalyzes insertion of Mg2+ into protoporphyrin IX (PPIX, proto to form Magnesium-protoporphyrin IX (MgPPIX, Mgproto, the first biosynthetic intermediate in the Chl branch. The GUN4 (genomes uncoupled 4 protein is not essential for the MgChel activity but has been shown to significantly stimulate its activity. We have isolated a light sensitive mutant, 6F14, by random DNA insertional mutagenesis. 6F14 cannot tolerate light intensities higher than 90-100 μmol photons m-2 s-1. It shows a light intensity dependent progressive photo-bleaching. 6F14 is incapable of photo-autotrophic growth under light intensity higher than 100 μmol photons m-2 s-1. PCR based analyses show that in 6F14 the insertion of the plasmid outside the GUN4 locus has resulted in a genetic rearrangement of the GUN4 gene and possible deletions in the genomic region flanking the GUN4 gene. Our gun4 mutant has a Chl content very similar to that in the wild type in the dark and is very sensitive to fluctuations in the light intensity in the environment unlike the earlier identified Chlamydomonas gun4 mutant. Complementation with a functional copy of the GUN4 gene restored light tolerance, Chl biosynthesis and photo-autotrophic growth under high light intensities in 6F14. 6F14 is the second gun4 mutant to be identified in C. reinhardtii. Additionally, we show that our two gun4 complements over-express the GUN4 protein and show a higher Chl content per cell compared to that in the wild type strain.

  10. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    International Nuclear Information System (INIS)

    Rimjaem, S.; Kusoljariyakul, K.; Thongbai, C.

    2014-01-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012 © . RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance

  11. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    Science.gov (United States)

    Rimjaem, S.; Kusoljariyakul, K.; Thongbai, C.

    2014-02-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012©. RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance.

  12. DC photoemission electron guns as ERL sources

    International Nuclear Information System (INIS)

    Sinclair, Charles K.

    2006-01-01

    Very-high-voltage DC electron guns, delivering moderate duration bunches from photoemission cathodes, and followed by conventional drift bunching and acceleration, offer a practical solution for an ERL injector. In a variant of this scheme, a DC gun is placed in close proximity to a superconducting RF accelerator cavity, with few or no active elements between the gun and cavity. The principal technical challenge with such electron guns arises from field emission from the cathode electrode and its support structure. Field emission may result in voltage breakdown across the cathode-anode gap, or a punch-through failure of the insulator holding off the cathode potential, as well as lesser though still serious problems. Various means to mitigate these problems are described. The operational lifetime of high quantum efficiency photocathodes in these guns is determined by the vacuum conditions, through phenomena such as chemical poisoning and ion back-bombardment. Minimization of the field strength on electrode structures pushes high-voltage DC guns toward large dimensions and, correspondingly, large outgassing loads, but it is also true that these guns offer many opportunities for achieving excellent vacuum conditions. Good solutions to vacuum problems that had previously limited cathode lifetime have been demonstrated in recent years. Designs for DC guns presently in use and planned for the near future will be described. The parameters necessary for a 100 mA average current, very-high-voltage DC gun with a photocathode operational lifetime greater than 100 h appear to be within reach, but have yet to be demonstrated. A 1 A average current source with good cathode operational lifetime will require developments beyond the present state-of-the-art

  13. RF gun using laser-triggered photocathode

    International Nuclear Information System (INIS)

    Akiyama, H.; Otake, Y.; Naito, T.; Takeuchi, Y.; Yoshioka, M.

    1992-01-01

    An RF gun using laser-triggered photocathode has many advantages as an injector of the linear colliders since it can generate a low emittance and high current pulsed beam. The experimental facility for the RF gun, such as an RF system, a laser system and a photocathode have been fabricated to study the fundamental characteristics. The dynamics of the RF gun has also studied by the 1D sheet beam model. (author)

  14. Four-quadrant propeller modeling: A low-order harmonic approximation

    Digital Repository Service at National Institute of Oceanography (India)

    Haeusler, A.J; Saccon, A.; Hauser, J; Pascoal, A.M.; Aguiar, A.P.

    . We explore the connection between the propeller thrust, torque, and efficiency curves and the lift and drag curves of the propeller blades. The model originates from a well-known four-quadrant model, based on a sinusoidal approximation...

  15. ENVIORNMENTAL TECHNOLOGY VERIFICATION REPORT: ANEST IWATA CORPORATION LPH400-LV HVLP SPRAY GUN

    Science.gov (United States)

    This Enviornmental Technology Verification reports on the characteristics of a paint spray gun. The research showed that the spray gun provided absolute and relative increases in transfer efficiency over the base line and provided a reduction in the use of paint.

  16. Spectroscopic Characterization of HAN-Based Liquid Gun Propellants and Nitrate Salt Solutions

    Science.gov (United States)

    1989-01-15

    spectra were recorded of bubbles of a concentrated aqueous nitrate solution, mineral oil, and an aqueous surfactant solution. Polymethacrylic acid ...FTIR spectra of droplets of a concentrated aqueous nitrate salt based solution (LGP1845), of solid particles cf polymethacrylic acid packing IO, 3... polymethacrylic acid low density packing foam cut to a 3x4 mnn rectangle was levitated with a low acoustic power. The sample was easily I positioned in the

  17. A line beam electron gun for rapid thermal processing

    Science.gov (United States)

    Pauli, M.; Müller, J.; Hartkopf, K.; Barth, T.

    1992-04-01

    A line beam electron gun based on the Pierce gun type was developed. The line cathode was realized by a directly heated tungsten rod. The temperature distribution along the tungsten rod was simulated numerically. The simulation shows a flat temperature across 2/3 of the cathode length and it agrees with appropriate measurable parameters. The beam profiles of the electron gun perpendicular to the line direction were examined as a function of electrical and geometrical parameters: The space-charge distribution in front of the cathode was found to be responsible for the shape of the beam profile. The shape of the beam profile is weakly influenced by the acceleration to the anode. The heating current induced voltage drop along the cathode was found to be responsible for the nonuniform emission in line direction. A model for the emission behavior of the line beam electron gun was developed. The model is based on the results of the measurements and on a numerical simulation of the potential distribution in the area between Pierce reflectors and anode. The emission model shows a solution to homogenize the emission by a suitable variation of geometrical parameters in line direction. A linear variation was realized in experiment which enables a uniform emission across 2/3 of the cathode length. The beam profile is adjustable by a bias voltage between the cathode and the Pierce reflectors.

  18. Stability measurements of the electron gun for the KATRIN rear section

    Energy Technology Data Exchange (ETDEWEB)

    Ebenhoech, Sylvia [Karlsruhe Institute of Technology (KIT) (Germany). Institute for Technical Physics (ITEP), Tritium Laboratory Karlsruhe (TLK); Collaboration: KATRIN-Collaboration

    2016-07-01

    The aim of the KArlsruhe TRItium Neutrino (KATRIN) experiment is to determine the antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.) by high-precision spectroscopy close to the tritium beta decay endpoint at 18.6 keV. To achieve the sensitivity aim both statistical and systematic uncertainties must be minimized. One contribution to the systematic error are uncertainties in the column density of the tritium source or in the source activity. In order to detect and monitor changes in the tritium source the Rear Section, which is integrated at the rear end of the KATRIN setup, is used. The Rear Section includes an angular selective electron gun (e-gun) based on the photoelectric effect. With the e-gun it will be possible e.g. to achieve a precise calibration of the column source density. To achieve the requirements on the e-gun a stable UV light source is essential to produce photoelectrons. The presentation focuses on the setup of the e-gun and intensity stability measurements of the UV light source setup.

  19. The electron gun for the Daresbury SRS linac

    International Nuclear Information System (INIS)

    Dykes, D.M.

    1996-01-01

    The electron gun for the Daresbury SRS linac injector has been modified to use the cathode-grid assembly from the Eimac planar triode 8755. The gun now has improved beam characteristics, is more reliable and the cathode assembly is quicker and easier to change. This paper describes the assembly of the electron gun, and then the re-conditioning of the cathode highlighting the vacuum environment. The action of the grid modulation system on the electron beam, which pre-bunches the electron beam, is described, and typical gun characteristics are shown. Proposed developments to the gun system are discussed. (author)

  20. Simulation of electron beam from two strip electron guns and control of power density by rotation of gun

    International Nuclear Information System (INIS)

    Sahu, G K; Baruah, S; Thakur, K B

    2012-01-01

    Electron beam is preferably used for large scale evaporation of refractory materials. Material evaporation from a long and narrow source providing a well collimated wedge shaped atomic beam has applications in isotopic purification of metals relevant to nuclear industry. The electron beam from an electron gun with strip type filament provides a linear heating source. However, the high power density of the electron beam can lead to turbulence of the melt pool and undesirable splashing of molten metal. For obtaining quiet surface evaporation, the linear electron beam is generally scanned along its length. To further reduce the power density to maintain quiet evaporation the width of the vapour source can be controlled by rotating the electron gun on its plane, thereby scanning an inclined beam over the molten pool. The rotation of gun has further advantages. When multiple strip type electron guns are used for scaling up evaporation length, a dark zone appears between two beams due to physical separation of adjacent guns. This dark zone can be reduced by rotating the gun and thereby bringing two adjacent beams closer. The paper presented here provides the simulation results of the electron beam trajectory and incident power density originating from two strip electron guns by using in-house developed code. The effect of electron gun rotation on the electron beam trajectory and power density is studied. The simulation result is experimentally verified with the image of molten pool and heat affected zone taken after experiment. This technique can be gainfully utilized in controlling the time averaged power density of the electron beam and obtaining quiet evaporation from the metal molten pool.

  1. The Mystery of the Gun Turret in the Desert

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, R. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-11-30

    The mystery of the gun turret in the desert began with an ingenious idea: to develop a reusable open-air line of sight diagnostic device to support LLNL’s early nuclear weapons development efforts. Obtained from the Mare Island Navy Shipyard (MINS) in January 1957, the gun turret traveled by ship to the Naval Construction Battalion base at Port Hueneme, California, and then by truck to Area 2 in the Yucca Flats valley at the Nevada Nuclear Security Site (NNSS).

  2. Mole gun injury.

    Science.gov (United States)

    Pistré, V; Rezzouk, J

    2013-09-01

    A mole gun is a weapon, which is used to trap and kill moles. This report provides an overview of the state of knowledge of mole gun injuries, comparable to blast injuries caused by fireworks, explosive or gunshot. Over a 2-year period, the authors reported their experience with ten hand injuries caused by mole gun. Radial side of the hand was often concerned, particularly the thumb. The authors explain their choices in the management of such lesions. Surgery was performed primarily and a large debridement currently seemed to offer the best outcome for the patient. Blast, crush, burns and lacerations may explain the higher rate of amputation to the digits. A long period of physiotherapy, specifically of the hand, was needed before the patient could return to work. This ballistic hand trauma encountered by surgeons requires knowledge and understanding of these injuries. It should be in accordance with firearms law because of severe injuries encountered and possible lethal wounds. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. TOPGUN: a new way to increase the beam brightness of rf guns

    International Nuclear Information System (INIS)

    Serafini, L.; Pagani, C.; Rivolta, R.; Ferrarion, M.

    1991-01-01

    A new method is presented to neutralize the RF induced emittance blow up generated inside RF electron Guns. The method is based on a multi-mode operation of the RF Gun cavity, which must be able to support both the accelerating mode (TM 010-π ) and a higher harmonic mode. The analytical study of the beam dynamics, which has been found in good agreement with the numerical simulations, shows that the growth of the normalized rms emittance, produced by the time dependent RF forces during the acceleration in the Gun, can be cancelled up to fourth order terms. This is of great relevance for the improvement of RF Gun performances, since the RF field contribution to the emittance blow up becomes negligible and no more dependent on the unch size. As shown in this paper, with such a new Gun, which is called 'TOPGUN', the way to attain high brightness beams becomes straightforward

  4. Development and implementation of a propeller test capability for GL-10 "Greased Lightning" propeller design

    Science.gov (United States)

    Duvall, Brian Edward

    Interest in small unmanned aerial vehicles has increased dramatically in recent years. Hybrid vehicles which allow forward flight as a fixed wing aircraft and a true vertical landing capability have always had applications. Management of the available energy and noise associated with electric propeller propulsion systems presents many challenges. NASA Langley has developed the Greased Lightning 10 (GL-10) vertical takeoff, unmanned aerial vehicle with ten individual motors and propellers. All are used for propulsion during takeoff and contribute to acoustic noise pollution which is an identified nuisance to the surrounding users. A propeller test capability was developed to gain an understanding of how the noise can be reduced while meeting minimum thrust requirements. The designed propeller test stand allowed for various commercially available propellers to be tested for potential direct replacement of the current GL-10 propellers and also supported testing of a newly designed propeller provided by the Georgia Institute of Technology. Results from the test program provided insight as to which factors affect the noise as well as performance characteristics. The outcome of the research effort showed that the current GL-10 propeller still represents the best choice of all the candidate propellers tested.

  5. Reevaluation of a twenty-four-month chronic toxicity/carcinogenicity study of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in the B6C3F1 hybrid mouse.

    Science.gov (United States)

    Parker, George A; Reddy, Gunda; Major, Michael A

    2006-01-01

    Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) has been widely used as an explosive in U.S. army munitions formulations since World War II. Two-year carcinogenicity studies revealed RDX to be noncarcinogenic in two strains of rats, but a 2-year carcinogenicity study in B6C3F1 mice revealed an increased incidence of hepatocellular neoplasms in females. Based on results of the study in B6C3F1 mice, RDX has been classified as a possible carcinogen. The authors reevaluated the archived histological sections from the B6C3F1 mouse study, using current histopathologic diagnostic criteria and interpretations. The earlier evaluation showed a statistically significant increase in the incidence of hepatocellular adenoma/carcinoma in female mice from the three highest dose groups (7, 35, and 175/100 mg/kg/day). The revaluation yielded a slightly lower incidence at each of the dose levels in female mice. The reduced number of hepatocellular neoplasms was largely due to reclassification of hepatocellular adenomas as foci of cytoplasmic alteration, in compliance with current diagnostic criteria. The reevaluation was reviewed by a pathology working group (PWG), which arrived at a consensus classification of each lesion. Based on the consensus diagnoses of the PWG, only one female group (35 mg/kg/day) showed a significant increase when compared to controls. The incidence of hepatocellular neoplasms for all groups, including the 35 mg/kg/day group, was within the reported incidence range for spontaneous hepatocellular neoplasms in female B6C3F1 mice. The increased incidence of hepatocellular neoplasms in female mice given RDX at 35 mg/kg/day was interpreted as equivocal evidence of a carcinogenic effect.

  6. 78 FR 66840 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Science.gov (United States)

    2013-11-07

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use With Caps AGENCY: Consumer Product Safety Commission. ACTION: Final rule. SUMMARY: Section 106 of the... regulations pertaining to caps intended for use with toy guns refer to obsolete equipment, but the ASTM F963...

  7. Development of coaxial rotating-plasma gun

    International Nuclear Information System (INIS)

    Ikehata, Takashi; Tanabe, Toshio; Mase, Hiroshi

    1985-01-01

    A rotating-plasma gun has been devised to produce plasma streams with higher rotational velocities. The working mechanism of the gun and the results of a preliminary experiment have been described. (author)

  8. Sustainable Range Management of RDX and TNT by Phytoremediation with Engineered Plants

    Science.gov (United States)

    2016-04-01

    pH 6.5. Change in absorbance at 340 nm was measured over 1 min. Significant difference from wild-type (WT) is shown by an asterisk and determined by...FINAL REPORT Sustainable Range Management of RDX and TNT by Phytoremediation with Engineered Plants SERDP Project ER-1498 APRIL 2016...by Phyoremediation with Engineered Plants 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER ER-1498 Neil C

  9. Characterization of polymorphic states in energetic samples of 1,3,5-trinitro-1,3,5-triazine (RDX) fabricated using drop-on-demand inkjet technology.

    Science.gov (United States)

    Emmons, Erik D; Farrell, Mikella E; Holthoff, Ellen L; Tripathi, Ashish; Green, Norman; Moon, Raphael P; Guicheteau, Jason A; Christesen, Steven D; Pellegrino, Paul M; Fountain, Augustus W

    2012-06-01

    The United States Army and the first responder community are evaluating optical detection systems for the trace detection of hazardous energetic materials. Fielded detection systems must be evaluated with the appropriate material concentrations to accurately identify the residue in theater. Trace levels of energetic materials have been observed in mutable polymorphic phases and, therefore, the systems being evaluated must be able to detect and accurately identify variant sample phases observed in spectral data. In this work, we report on the novel application of drop-on-demand technology for the fabrication of standardized trace 1,3,5-trinitro-1,3,5-triazine (RDX) samples. The drop-on-demand sample fabrication technique is compared both visually and spectrally to the more commonly used drop-and-dry technique. As the drop-on-demand technique allows for the fabrication of trace level hazard materials, concerted efforts focused on characterization of the polymorphic phase changes observed with low concentrations of RDX commonly used in drop-on-demand processing. This information is important when evaluating optical detection technologies using samples prepared with a drop-on-demand inkjet system, as the technology may be "trained" to detect the common bulk α phase of the explosive based on its spectral features but fall short in positively detecting a trace quantity of RDX (β-phase). We report the polymorphic shifts observed between α- and β-phases of this energetic material and discuss the conditions leading to the favoring of one phase over the other.

  10. Modeling and Fault Simulation of Propellant Filling System

    International Nuclear Information System (INIS)

    Jiang Yunchun; Liu Weidong; Hou Xiaobo

    2012-01-01

    Propellant filling system is one of the key ground plants in launching site of rocket that use liquid propellant. There is an urgent demand for ensuring and improving its reliability and safety, and there is no doubt that Failure Mode Effect Analysis (FMEA) is a good approach to meet it. Driven by the request to get more fault information for FMEA, and because of the high expense of propellant filling, in this paper, the working process of the propellant filling system in fault condition was studied by simulating based on AMESim. Firstly, based on analyzing its structure and function, the filling system was modular decomposed, and the mathematic models of every module were given, based on which the whole filling system was modeled in AMESim. Secondly, a general method of fault injecting into dynamic system was proposed, and as an example, two typical faults - leakage and blockage - were injected into the model of filling system, based on which one can get two fault models in AMESim. After that, fault simulation was processed and the dynamic characteristics of several key parameters were analyzed under fault conditions. The results show that the model can simulate effectively the two faults, and can be used to provide guidance for the filling system maintain and amelioration.

  11. Plural beam electron gun assembly

    International Nuclear Information System (INIS)

    Stratton, M.G.

    1977-01-01

    The invention relates to a cathode ray tube plural-beam-in-line bi-potential electron gun assembly, having applied beam currents of differing levels, manifests structurally modified gun structures to effect focused beam landings at the screen that are evidenced as substantially equi-sized spots thereby providing improved resolution and brightness of the screen imagery. The structural changes embody modifications of the related focusing and accelerator electrodes of the respective guns to provide a partial telescoping arrangement for effecting the discrete placement, forming and shielding of the final focusing lenses. The three lenses so formed are in different planes in partial overlapping axial relationship

  12. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    Energy Technology Data Exchange (ETDEWEB)

    Rimjaem, S., E-mail: sakhorn.rimjaem@cmu.ac.th [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics (ThEP), Commission on Higher Education, Bangkok 10400 (Thailand); Kusoljariyakul, K.; Thongbai, C. [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics (ThEP), Commission on Higher Education, Bangkok 10400 (Thailand)

    2014-02-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012{sup ©}. RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance.

  13. The Effect of Light Casings on the Blast Parameters from a Spherical Charge of RDX/TNT 60/40

    National Research Council Canada - National Science Library

    Bishop, Valerie J; James, D. J

    1968-01-01

    .... High speed cine films were taken of the fireball growth. Peak overpressure and impulse enhancement over the values from an uncased RDX/TNT charge were obtained only from the thickest lead casing...

  14. Brief use of a specific gun in a violent game does not affect attitudes towards that gun

    OpenAIRE

    Hilgard, Joseph; Engelhardt, Christopher R.; Bartholow, Bruce D.

    2016-01-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) ...

  15. Gun ownership and firearm-related deaths.

    Science.gov (United States)

    Bangalore, Sripal; Messerli, Franz H

    2013-10-01

    A variety of claims about possible associations between gun ownership rates, mental illness burden, and the risk of firearm-related deaths have been put forward. However, systematic data on this issue among various countries remain scant. Our objective was to assess whether the popular notion "guns make a nation safer" has any merits. Data on gun ownership were obtained from the Small Arms Survey, and for firearm-related deaths from a European detailed mortality database (World Health Organization), the National Center for Health Statistics, and others. Crime rate was used as an indicator of safety of the nation and was obtained from the United Nations Surveys of Crime Trends. Age-standardized disability-adjusted life-year rates due to major depressive disorder per 100,000 inhabitants with data obtained from the World Health Organization database were used as a putative indicator for mental illness burden in a given country. Among the 27 developed countries, there was a significant positive correlation between guns per capita per country and the rate of firearm-related deaths (r = 0.80; P ownership and mental illness as independent covariates, gun ownership was a significant predictor (P <.0001) of firearm-related deaths, whereas mental illness was of borderline significance (P = .05) only. The number of guns per capita per country was a strong and independent predictor of firearm-related death in a given country, whereas the predictive power of the mental illness burden was of borderline significance in a multivariable model. Regardless of exact cause and effect, however, the current study debunks the widely quoted hypothesis that guns make a nation safer. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Ion plasma electron gun

    International Nuclear Information System (INIS)

    Wakalopulos, G.

    1976-01-01

    In the disclosed electron gun positive ions generated by a hollow cathode plasma discharge in a first chamber are accelerated through control and shield grids into a second chamber containing a high voltage cold cathode. These positive ions bombard a surface of the cathode causing the cathode to emit secondary electrons which form an electron beam having a distribution adjacent to the cathode emissive surface substantially the same as the distribution of the ion beam impinging upon the cathode. After passing through the grids and the plasma discharge chamber, the electron beam exits from the electron gun via a foil window. Control of the generated electron beam is achieved by applying a relatively low control voltage between the control grid and the electron gun housing (which resides at ground potential) to control the density of the positive ions bombarding the cathode

  17. SSRL photocathode RF gun test stand

    International Nuclear Information System (INIS)

    Hernandez, M.; Baltay, M.; Boyce, A.

    1995-01-01

    A photocathode RF gun test stand designed for the production and study of high brightness electron beams will be constructed at SSRL. The beam will be generated from a laser driven third generation photocathode RF gun being developed in collaboration with BNL, LBL, and UCLA. The 3-5 [MeV] beam from the gun will be accelerated using a SLAC three meter S-band accelerator section, in order to achieve the desired low emittance beam, emittance compensation with solenoidal focusing will be employed

  18. Status and future prospects of SRF gun developments

    International Nuclear Information System (INIS)

    Teichert, Jochen

    2006-01-01

    While the concepts of DC and normal-conducting photo-injectors are well proofed, the SRF gun development still possesses a high risk. Challenges are the thermal and contaminant isolation needed between the cathode and superconducting cavity, the choice of the right photocathode and its life time, the difficulty of coupling high-average power into the gun, and beam excitation of higher order cavity modes. But in combination with SRF linacs, the SRF guns are the best solution for high current and CW operation. Thus, several R and D projects of SRF gun have been launched. The talk will give an overview of the history and progress of the SRF gun development. In more detail the technical concept, performance, and status of the Rossendorf superconducting RF gun project, a collaboration of BESSY, DESY, MBI and FZR, will be presented. (author)

  19. The thermal decomposition behavior of ammonium perchlorate and of an ammonium-perchlorate-based composite propellant

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, R.; Minier, L.

    1998-03-24

    The thermal decomposition of ammonium perchlorate (AP) and ammonium-perchlorate-based composite propellants is studied using the simultaneous thermogravimetric modulated beam mass spectrometry (STMBMS) technique. The main objective of the present work is to evaluate whether the STMBMS can provide new data on these materials that will have sufficient detail on the reaction mechanisms and associated reaction kinetics to permit creation of a detailed model of the thermal decomposition process. Such a model is a necessary ingredient to engineering models of ignition and slow-cookoff for these AP-based composite propellants. Results show that the decomposition of pure AP is controlled by two processes. One occurs at lower temperatures (240 to 270 C), produces mainly H{sub 2}O, O{sub 2}, Cl{sub 2}, N{sub 2}O and HCl, and is shown to occur in the solid phase within the AP particles. 200{micro} diameter AP particles undergo 25% decomposition in the solid phase, whereas 20{micro} diameter AP particles undergo only 13% decomposition. The second process is dissociative sublimation of AP to NH{sub 3} + HClO{sub 4} followed by the decomposition of, and reaction between, these two products in the gas phase. The dissociative sublimation process occurs over the entire temperature range of AP decomposition, but only becomes dominant at temperatures above those for the solid-phase decomposition. AP-based composite propellants are used extensively in both small tactical rocket motors and large strategic rocket systems.

  20. Innovative Swirl Injector for LOX and Hydrocarbon Propellants, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Gases trapped in the propellant feed lines of space-based rocket engines due to cryogenic propellant boil-off or pressurant ingestion can result in poor combustion...

  1. Simple light gas guns for hypervelocity studies

    International Nuclear Information System (INIS)

    Combs, S.K.; Haselton, H.H.; Milora, S.L.

    1990-01-01

    Two-stage light guns are used extensively in hypervelocity research. The applications of this technology include impact studies and special materials development. Oak Ridge National Laboratory (ORNL) has developed two-stage guns that accelerate small projectiles (4-mm nominal diameter) to velocities of up to ∼5 km/s. These guns are relatively small and simple (thus, easy to operate), allowing a significant number of test shots to be carried out and data accumulated in a short time. Materials that have been used for projectiles include plastics, frozen isotopes of hydrogen, and lithium hydride. One gun has been used to demonstrate repetitive operation at a rate of 0.7 Hz; and, with a few design improvements, it appears capable of performing at firing frequencies of 1--2 Hz. A schematic of ORNL two-stage device is shown below. Unlike most such devices, no rupture disks are used. Instead, a fast valve (high-flow type) initiates the acceleration process in the first stage. Projectiles can be loaded into the gun breech via the slide mechanism; this action has been automated which allows repetitive firing. Alternatively, the device is equipped with ''pipe gun'' apparatus in which gas can be frozen in situ in the gun barrel to form the projectile. This equipment operates with high reliability and is well suited for small-scale testing at high velocity. 17 refs., 6 figs., 2 tabs

  2. Development of a Low Strain-Rate Gun Propellant Bed Compression Test and its Use in Evaluating Mechanical Response

    Science.gov (United States)

    2016-09-01

    compression may be expected, as there will be minimal void spaces remaining into which fragmentation or plastic flow is possible. This behaviour is...Universal gas constant (8.314 J.K-1.mol-1) r Radial position ro Outer die radius ri Inner die radius SA Surface Area SR Secret Research T...is relatively simple to perform and is reported to provide good indications with respect to propellant bed behaviour during the first stages of

  3. Separating Batterers and Guns: A Review and Analysis of Gun Removal Laws in 50 States

    Science.gov (United States)

    Frattaroli, Shannon; Vernick, Jon S.

    2006-01-01

    Firearms play an important role in lethal domestic violence incidents. The authors review state laws regarding two policies to separate batterers from firearms: laws authorizing police to remove firearms when responding to a domestic violence complaint ("police gun removal laws") and laws authorizing courts to order guns removed from batterers…

  4. Developments in electron gun simulation

    Science.gov (United States)

    Herrmannsfeldt, W. B.

    1997-01-01

    This paper will discuss the developments in the electron gun simulation programs that are based on EGUN and its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications on EGN2 of this evolution will be discussed. Some examples and a review of the capabilities of the EGUN family will be described.

  5. Developments in electron gun simulation

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1994-05-01

    This paper will discuss the developments in the electron gun simulation programs that are based on EGUN and its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications on EGN2 of this evolution will be discussed. Some examples and a review of the capabilities of the EGUN family will be described

  6. Study of Control Grid Thermionic Cathode RF Gun

    CERN Document Server

    Xiao, Jin; Ming, Li; Xinfan, Yang; Xumin, Shen; Yanan, Chen; Zhou, Xu

    2004-01-01

    In this paper, the beam loading effect of RF Gun was analyzed. To minimize the energy spread, the grid control RF Gun was introduced. The result shows that the grid congrol RF Gun can increase electron beam within 1% energy spread.

  7. Klystron - Space-charge limited flow, guns, Perveance

    International Nuclear Information System (INIS)

    Isagawa, S.

    1999-01-01

    This paper treats Thermionic emission, Cathode as an e - emitter, Space-charge limited effect and 3/2 power law, Perveance, Beam spread due to space charge, Pierce guns, Magnetically immersed guns, Method of gun design including simulations, and Examples, mainly treating E3786, which attendees will operate above 1 MW-CW in a practical exercise course at KEK. (author). 74 refs

  8. Beam Dynamics Simulation of Photocathode RF Electron Gun at the PBP-CMU Linac Laboratory

    Science.gov (United States)

    Buakor, K.; Rimjaem, S.

    2017-09-01

    Photocathode radio-frequency (RF) electron guns are widely used at many particle accelerator laboratories due to high quality of produced electron beams. By using a short-pulse laser to induce the photoemission process, the electrons are emitted with low energy spread. Moreover, the photocathode RF guns are not suffered from the electron back bombardment effect, which can cause the limited electron current and accelerated energy. In this research, we aim to develop the photocathode RF gun for the linac-based THz radiation source. Its design is based on the existing gun at the PBP-CMU Linac Laboratory. The gun consists of a one and a half cell S-band standing-wave RF cavities with a maximum electric field of about 60 MV/m at the centre of the full cell. We study the beam dynamics of electrons traveling through the electromagnetic field inside the RF gun by using the particle tracking program ASTRA. The laser properties i.e. transverse size and injecting phase are optimized to obtain low transverse emittance. In addition, the solenoid magnet is applied for beam focusing and emittance compensation. The proper solenoid magnetic field is then investigated to find the optimum value for proper emittance conservation condition.

  9. Gunning for accuracy: Company targets human error with 'foolproof' perforating gun

    Energy Technology Data Exchange (ETDEWEB)

    Ross, E.

    2002-12-01

    An innovative new design for a scalloped expandable perforating gun is described. The gun is manufactured in Edmonton by LRI Perforating Systems, and it aimed at reducing the chances of human error that can result in sub-optimal performance. A perforating gun is used to pierce the well's casing to allow hydrocarbons to flow into the wellbore. It consists of a carrier, a pipe with an eighth-inch thick wall that protects the explosives downhole, and an inner tube containing the explosives. The LRI system has a unique interlocking mechanism for the end plates, which are attached to either end of the thin-walled charge holder tube, in addition to other advantageous features, including a price advantage of 10 to 15 per cent. Marketing strategy is designed to interest wi reline companies that focus on vertical well applications. 1 photo.

  10. Design and experiment of high-current low-pressure plasma-cathode e-gun

    International Nuclear Information System (INIS)

    Xie Wenkai; Li Xiaoyun; Wang Bin; Meng Lin; Yan Yang; Gao Xinyan

    2006-01-01

    The preliminary design of a new high-power low pressure plasma-cathode e-gun is presented. Based on the hollow cathode effect and low-pressure glow discharge empirical formulas, the hollow cathode, the accelerating gap, and the working gas pressure region are given. The general experimental device of the low-pressure plasma cathode electron-gun generating high current density e-beam source is shown. Experiments has been done in continuous filled-in gases and gases-puff condition, and the discharging current of 150-200 A, the width of 60 μs and the collector current of 30-80 A, the width of 60 μs are obtained. The results show that the new plasma cathode e-gun can take the place of material cathode e-gun, especially in plasma filled microwave tubes. (authors)

  11. Emittance measurement for high-brightness electron guns

    International Nuclear Information System (INIS)

    Kobayashi, H.; Kurihara, T.; Sato, I.; Asami, A.; Yamazaki, Y.; Otani, S.; Ishizawa, Y.

    1992-01-01

    An emittance measurement system based on a high-precision pepper-pot technique has been developed for electron guns with low emittance of around πmm-mrad. Electron guns with a 1 mmφ cathode, the material of which is impregnated tungsten or single-crystal lanthanum hexaboride (La 1-x Ce x )B 6 , have been developed. The performance has been evaluated by putting stress on cathode roughness, which gives rise to an angular divergence, according to the precise emittance measurement system. A new type of cathode holder, which is a modified version of the so called Vogel type, was developed and the beam uniformity has been improved. (Author) 5 figs., tab., 9 refs

  12. Characteristics of the ETA gun

    International Nuclear Information System (INIS)

    Paul, A.C.; Neil, V.K.; Craig, G.D.; Fessenden, T.J.

    1981-01-01

    The Experimental Test Accelerator (ETA) is a linear induction device consisting of a 2.5-MV electron gun and ten 0.25-MV accelerating units designed to produce a 10-kA beam of electrons at 5 MeV. Calculations with the computer code EBQ as well as experimental measurements indicate that the current produced by the gun is limited by two phenomena. The first arises from the variation of particle energy with time during the pulse. Only particles with energy within a limited range can be transported by the focusing coils in the gun: therefore the variation of the gun's output current with time is determined by the coil settings. The second effect results from a collective interaction at sufficiently large current to cause a virtual cathode to form a few centimeters past the extraction grid. Operation in this regime results in greatly increased beam emittance and poor beam transport through the accelerator. Results of the code calculations are compared with experimental data and found to be in good agreement. (author)

  13. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source

    Science.gov (United States)

    Wells, R. P.; Ghiorso, W.; Staples, J.; Huang, T. M.; Sannibale, F.; Kramasz, T. D.

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  14. Thermionic gun control system for the CEBAF [Continuous Electron Beam Accelerator Facility] injector

    International Nuclear Information System (INIS)

    Pico, R.; Diamond, B.; Fugitt, J.; Bork, R.

    1989-01-01

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  15. Project Minerva: A low-cost manned Mars mission based on indigenous propellant production

    Science.gov (United States)

    Bruckner, Adam P.; Anderson, Hobie; Caviezel, Kelly; Daggert, Todd; Folkers, Mike; Fornia, Mark; Hamling, Steven; Johnson, Bryan; Kalberer, Martin; Machula, Mike

    1992-01-01

    Project Minerva is a low-cost manned Mars mission designed to deliver a crew of four to the Martian surface, using only two sets of two launches. Key concepts which make this mission realizable are the use of near-term technologies and in-situ propellant production, following the senario originally proposed by R. Zubrin of Martin Marietta. The first set of launches delivers two unmanned payloads into low earth orbit (LEO): one consists of an Earth Return Vehicle (ERV), a propellant production plant, and a set of robotic vehicles, and the second consists of the upper stage/trans-Mars injection (TMI) booster. In LEO, the two payloads are joined and inserted into a Mars transfer orbit. The landing on Mars is performed with the aid of multiple aerobraking maneuvers. On the Martian surface, the propellant production plant uses a Sabatier/electrolysis-type process to combine six tons of hydrogen brought from earth with carbon dioxide from the Martian atmosphere to produce 100 tons of liquid oxygen and methane, which are later used as the propellants for the rover expeditions and the manned return journey of the ERV. Once the in-situ propellant production is completed, approximately two years after the first set of launches, the manned portion of the mission leaves earth. This set of two launches is similar to that of the unmanned vehicles; the two payloads are the Manned Transfer Vehicle (MTV) and the upper stage/TMI booster. The MTV contains the manned rover and the habitat which houses the astronauts enroute to Mars and on the Martian surface. During the 180-day trip to Mars, artificial gravity is created by tethering the MTV to the TMI booster and inducing rotation. Upon arrival the MTV performs aerobraking maneuvers to land near the fully-fueled ERV, which will be used by the crew a year and a half later to return to earth. The mission entails moderate travel times with relatively low-energy conjunction-class trajectories and allows ample time for scientific

  16. Superconducting augmented rail gun (SARG)

    International Nuclear Information System (INIS)

    Homan, C.G.; Cummings, C.E.; Fowler, C.M.

    1986-01-01

    Superconducting augmentation consists of a superconducting coil operating in the persistent mode closely coupled magnetically with a normally conducting rail gun. A theoretical investigation of the effect of this system on a rail gun has shown that two benefits occur. Projectile velocities and launch efficiencies increase significantly depending on the magnetic coupling between the rail and augmentation circuits. Previous work evaluated an idealized system by neglecting energy dissipation effects. In this paper, the authors extend the analysis to include the neglected terms and show improved actual launch efficiencies for the SARG configuration. In this paper, the authors discuss details of projectile design in depth and present preliminary results of rail gun performance

  17. Cerebral damage caused by nail gun injury

    DEFF Research Database (Denmark)

    Andersen, Chris

    2016-01-01

    Background Accidents with nail guns are rather common, especially in the construction industry. Most injuries involve the extremities and several present with intracerebral injuries. When the patient is unconscious, it can be a big challenge to determine whether the injury is an accident, self....... The forensic examination showed lesions of intracranial surgery and minor bruises on the arms. No sign of defense injuries was found. There were no signs of malfunction of the nail gun-wielding robot. On the side of the machine, there were a handheld nail gun and the police investigated the case as a possible...... criminal act. They found bloodstains on the back of the machine. When awake, the man explained, that by accident, he had hit his head against a nail gun and as a result of this, the nail gun delivered a nail into his skull. Conclusion Sometimes, the circumstances of a case are not clear...

  18. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5-Triazine (RDX) (Public Comment Draft)

    Science.gov (United States)

    EPA is developing an Integrated Risk Information System (IRIS) assessment of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and has released the draft assessment for public comment. When final, the assessment will appear on the IRIS database.

  19. Geometry Optimization of DC/RF Photoelectron Gun

    CERN Document Server

    Chen Ping; Yu, David

    2005-01-01

    Pre-acceleration of photoelectrons in a pulsed, high voltage, short, dc gap and its subsequent injection into an rf gun is a promising method to improve electron beam emittance in rf accelerators. Simulation work has been performed in order to optimize the geometric shapes of a dc/rf gun and improve electron beam properties. Variations were made on cathode and anode shapes, dc gap distance, and inlet shape of the rf cavity. Simulations showed that significant improvement on the normalized emittance (< 1 mm-mrad), compared to a dc gun with flat cathode, could be obtained after the geometric shapes of the gun were optimized.

  20. Society of Behavioral Medicine (SBM) position statement: restore CDC funding for firearms and gun violence prevention research.

    Science.gov (United States)

    Behrman, Pamela; Redding, Colleen A; Raja, Sheela; Newton, Tamara; Beharie, Nisha; Printz, Destiny

    2018-02-21

    The Society for Behavioral Medicine (SBM) urges restoration of Centers for Disease Control and Prevention (CDC) funding for firearms and gun violence prevention research. Gun violence in the United States is an important and costly public health issue in need of research attention. Unfortunately, there have been no concerted CDC-funded research efforts in this area since 1996, due to the passage of the Dickey Amendment. To remedy the information-gathering restrictions caused by the Dickey Amendment bans, it is recommended that Congress remove 'policy riders' on federal appropriations bills that limit firearms research at the CDC; expand NVDRS firearms-related data collection efforts to include all fifty states; fund CDC research on the risk and protective factors of gun use and gun violence prevention; fund research on evidence-based primary, secondary, and tertiary prevention and treatment initiatives for communities that are seriously impacted by the effects of gun violence; and support the development of evidence-based policy and prevention recommendations for gun use and ownership.

  1. NASA-Ames vertical gun

    Science.gov (United States)

    Schultz, P. H.

    1984-01-01

    A national facility, the NASA-Ames vertical gun range (AVGR) has an excellent reputation for revealing fundamental aspects of impact cratering that provide important constraints for planetary processes. The current logistics in accessing the AVGR, some of the past and ongoing experimental programs and their relevance, and the future role of this facility in planetary studies are reviewed. Publications resulting from experiments with the gun (1979 to 1984) are listed as well as the researchers and subjects studied.

  2. ATA injector-gun calculations

    International Nuclear Information System (INIS)

    Paul, A.C.

    1981-01-01

    ATA is a pulsed, 50 ns 10 KA, 50 MeV linear induction electron accelerator at LLNL. The ETA could be used as an injector for ATA. However the possibility of building a new injector gun for ATA, raised the question as to what changes from the ETA gun in electrode dimensions or potentials, if any, should be considered. In this report the EBQ code results for the four electrode configurations are reviewed and an attempt is made to determine the geometrical scaling laws appropriate to these ETA type gun geometries. Comparison of these scaling laws will be made to ETA operation. The characteristic operating curves for these geometries will also be presented and the effect of washer position determined. It will be shown that emittance growth will impose a limitation on beam current for a given anode potential before the virtual cathode limit is reached

  3. (Bio)degradation of RDX and HMX in Marine/Estuarine Water and Sediments

    Science.gov (United States)

    2006-09-01

    four fungal strains Rhodotorula sp . HAW-OCF1, Bullera sp . HAW-OCF2, Acremonium sp . HAW-OCF3 and Penicillium sp . HAW-OCF5, were isolated as RDX...represent four novel species of Shewanella described as follows: Shewanella sediminis sp . nov.: Strain HAW-EB3T contains lysine decarboxylase that is...We proposed Shewanella sediminis sp . nov. with HAW-EB3T (= NCIMB 14036T = DSM 17055T) as the type strain (Zhao et al. 2005). Shewanella halifaxensis

  4. ECR ion source with electron gun

    Science.gov (United States)

    Xie, Zu Q.; Lyneis, Claude M.

    1993-01-01

    An Advanced Electron Cyclotron Resonance ion source (10) having an electron gun (52) for introducing electrons into the plasma chamber (18) of the ion source (10). The ion source (10) has a injection enclosure (12) and a plasma chamber tank (14). The plasma chamber (18) is defined by a plurality of longitudinal magnets (16). The electron gun (52) injects electrons axially into the plasma chamber (18) such that ionization within the plasma chamber (18) occurs in the presence of the additional electrons produced by the electron gun (52). The electron gun (52) has a cathode (116) for emitting electrons therefrom which is heated by current supplied from an AC power supply (96) while bias potential is provided by a bias power supply (118). A concentric inner conductor (60) and Outer conductor (62) carry heating current to a carbon chuck (104) and carbon pusher (114) Which hold the cathode (116) in place and also heat the cathode (16). In the Advanced Electron Cyclotron Resonance ion source (10), the electron gun (52) replaces the conventional first stage used in prior art electron cyclotron resonance ion generators.

  5. Revised theory of Pierce-type electron guns

    International Nuclear Information System (INIS)

    Sar-El, H.Z.

    1982-01-01

    Attempts to date to obtain the shape of the beam forming electrodes of various Pierce-type electron guns are briefly discussed with emphasis on the many discrepansis in the results of previous works. A revised theory of Pierce-type electron guns is proposed. The shapes of the beam-forming electrodes for all known configurations of Pierce guns were computed on the basis of the proposed theory. (orig.)

  6. Gas injected washer plasma gun

    International Nuclear Information System (INIS)

    Jain, K.K.; John, P.I.; Punithavelu, A.M.; Rao, P.P.

    1980-01-01

    A plasma gun similar in geometry to the washer plasma gun has been operated with gas injected externally. hydrogen, nitrogen and argon plasmas have been ionised and accelerated to velocities of the order of 10 7 mm s -1 and densities 10 11 mm -3 . Higher parameter range is possible with higher electrical input power. (author)

  7. Gun Concerns Personal for Duncan

    Science.gov (United States)

    McNeil, Michele

    2013-01-01

    As U.S. Secretary of Education Arne Duncan works with other Obama administration officials on policy responses to the shootings at a Connecticut elementary school, he brings a personal and professional history that has acquainted him with the impact of gun violence. As schools chief in Chicago from 2001 to 2008, he was affected by the gun deaths…

  8. Association Between Gambling and Exposure to Guns Among Cocaine-Using Women.

    Science.gov (United States)

    Vaddiparti, Krishna; Striley, Catherine W; Cottler, Linda B

    2016-09-01

    The purpose of this study is to assess the association between gambling severity and exposure to guns among substance-using women recruited in the community. Data for these analyses come from the baseline phase of two community-based HIV prevention interventions conducted among alcohol and drug-using women in St. Louis, MO. Gun exposure was assessed using the Violence Exposure Questionnaire (VEQ), and DSM-IV pathological gambling (PG) symptoms and other psychiatric symptoms were assessed using the Computerized Diagnostic Interview Schedule; The Composite International Diagnostic Interview Substance Abuse Module assessed DSM-IV substance dependence, including cocaine dependence and alcohol dependence. Women in the study were predominantly African American (80%), mean age was 35.70 years ±8.8. Women exposed to guns were significantly more likely than women not exposed to guns to have gambled with all consequences: without meeting PG criteria (21% vs. 15%); to meet 1 to 4 PG criteria (22% vs. 12%), and to report 5 or more PG criteria (10% vs. 5%). These differences were significant at p  gambled without PG symptoms (OR = 1.77; 95% CI = 1.10-2.85) were nearly twice more likely to have exposure to guns than women who did not gamble. The risk for gun exposure increased with severity of gambling. Women who gambled and reported one to four PG criteria were twice as likely to have had an exposure to guns (OR 2.04; 95% CI = 1.45-3.06) and this risk increased to nearly threefold among women who met five or more criteria of PG (OR 2.65; 95% CI = 1.32-5.32). In addition, endorsing five or more criteria for major depressive disorder (OR 1.44; 95% CI = 1.00-2.06) and three or more criteria for antisocial personality adult criteria (OR 3.78; 95% CI = 2.03-7.02) were strong predictors for gun exposure among these women. The findings indicate that substance-using women with gambling behavior are at an enhanced risk to have exposure to guns.

  9. Gun Safety Management with Patients at Risk for Suicide

    Science.gov (United States)

    Simon, Robert I.

    2007-01-01

    Guns in the home are associated with a five-fold increase in suicide. All patients at risk for suicide must be asked if guns are available at home or easily accessible elsewhere, or if they have intent to buy or purchase a gun. Gun safety management requires a collaborative team approach including the clinician, patient, and designated person…

  10. A Viscosity-Based Model for Bubble-Propelled Catalytic Micromotors

    Directory of Open Access Journals (Sweden)

    Zhen Wang

    2017-06-01

    Full Text Available Micromotors have shown significant potential for diverse future applications. However, a poor understanding of the propelling mechanism hampers its further applications. In this study, an accurate mechanical model of the micromotor has been proposed by considering the geometric asymmetry and fluid viscosity based on hydrodynamic principles. The results obtained from the proposed model are in a good agreement with the experimental results. The effects of the semi-cone angle on the micromotor are re-analyzed. Furthermore, other geometric parameters, like the length-radius aspect ratio, exert great impact on the velocity. It is also observed that micromotors travel much slower in highly viscous solutions and, hence, viscosity plays an important role.

  11. Propellers in Saturn's rings

    Science.gov (United States)

    Sremcevic, M.; Stewart, G. R.; Albers, N.; Esposito, L. W.

    2013-12-01

    Theoretical studies and simulations have demonstrated the effects caused by objects embedded in planetary rings. Even if the objects are too small to be directly observed, each creates a much larger gravitational imprint on the surrounding ring material. These strongly depend on the mass of the object and range from "S" like propeller-shaped structures for about 100m-sized icy bodies to the opening of circumferential gaps as in the case of the embedded moons Pan and Daphnis and their corresponding Encke and Keeler Gaps. Since the beginning of the Cassini mission many of these smaller objects (~data from Cassini Ultraviolet Imaging Spectrograph (UVIS) and Imaging Science Subsystem (ISS) experiments. We show evidence that B ring seems to harbor two distinct populations of propellers: "big" propellers covering tens of degrees in azimuth situated in the densest part of B ring, and "small" propellers in less dense inner B ring that are similar in size and shape to known A ring propellers. The population of "big" propellers is exemplified with a single object which is observed for 5 years of Cassini data. The object is seen as a very elongated bright stripe (40 degrees wide) in unlit Cassini images, and dark stripe in lit geometries. In total we report observing the feature in images at 18 different epochs between 2005 and 2010. In UVIS occultations we observe this feature as an optical depth depletion in 14 out of 93 occultation cuts at corrotating longitudes compatible with imaging data. Combining the available Cassini data we infer that the object is a partial gap located at r=112,921km embedded in the high optical depth region of the B ring. The gap moves at Kepler speed appropriate for its radial location. Radial offsets of the gap locations in UVIS occultations are consistent with an asymmetric propeller shape. The asymmetry of the observed shape is most likely a consequence of the strong surface mass density gradient, as the feature is located at an edge between

  12. Law Enforcement and Gun Retailers as Partners for Safely Storing Guns to Prevent Suicide: A Study in 8 Mountain West States.

    Science.gov (United States)

    Runyan, Carol W; Brooks-Russell, Ashley; Brandspigel, Sara; Betz, Marian; Tung, Gregory; Novins, Douglas; Agans, Robert

    2017-11-01

    To examine the extent to which law enforcement agencies (LEAs) and gun retailers are willing to offer voluntary, temporary storage as a part of an overall suicide prevention effort. We invited all LEAs and gun retailers in 8 US states to respond to questionnaires asking about their willingness to offer temporary gun storage and their recommendations to gun owners about safe storage. We collected data in 2016 from 448 LEAs and 95 retailers (response rates of 53% and 25%, respectively). Three quarters of LEAs (74.8%; 95% confidence interval [CI] = 72.1, 77.5) indicated they already provided temporary storage compared with 47.6% (95% CI = 39.2, 56.0) of retailers. LEAs were most willing to provide storage when a gun owner was concerned about the mental health of a family member. Retailers were more receptive than were LEAs to providing storage when visitors were coming or for people wanting storage while traveling. Both groups recommended locking devices within the home, but LEAs were slightly more favorable to storing guns away from the home. Law enforcement agencies and gun retailers are important resources for families concerned about suicide.

  13. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5-Triazine (RDX) (Preliminary Assessment Materials)

    Science.gov (United States)

    In August 2013, EPA released the draft literature searches and associated search strategies, evidence tables, and exposure response arrays for RDX to obtain input from stakeholders and the public prior to developing the draft IRIS assessment. Specifically, EPA was interested in c...

  14. Trapping of gun-injected plasma by a tokamak

    International Nuclear Information System (INIS)

    Leonard, A.W.; Dexter, R.N.; Sprott, J.C.

    1986-01-01

    It is shown that a plasma produced by a Marshall gun can be injected into and trapped by a tokamak plasma. Gun injection raises the line-averaged density and peaks the density profile. Trapping of the gun-injected plasma is explainable in terms of a depolarization current mechanism

  15. Quantum efficiency temporal response and lifetime of a GaAs cathode in SRF electron gun

    International Nuclear Information System (INIS)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.; Burrill, A.; Rao, T.; Wu, Q.; Holmes, D.

    2010-01-01

    RF electron guns with a strained super lattice GaAs cathode can generate polarized electron beam of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface. In a normal conducting RF gun, the extremely high vaccum required by these cathodes can not be met. We report on an experiment with a superconducting SRF gun, which can maintain a vacuum of nearly 10-12 torr because of cryo-pumping at the temperature of 4.2K. With conventional activation, we obtained a QE of 3% at 532 nm, with lifetime of nearly 3 days in the preparation chamber. We plan to use this cathode in a 1.3 GHz 1/2 cell SRF gun to study its performance. In addition, we studied the multipacting at the location of cathode. A new model based on the Forkker-Planck equation which can estimate the bunch length of the electron beam is discussed in this paper. Future particle accelerators such as eRHIC and ILC require high brightness, high current polarized electrons Recently, using a superlattice crystal, the maximum polarization of 95% was reached. Activation with Cs,O lowers the electron affinity and makes it energetically possible for all the electrons excited in to the conduction band and reach the surface to escape into the vacuum. Presently the polarized electron sources are based on DC gun, such as that at the CEBAF at Jlab. In these devices, the life time of the cathode is extended due to the reduced back bombardment in their UHV conditions. However, the low accelerating gradient of the DC guns lead to poor longitudinal emittance. The higher accelerating gradient of the RF gun generates low emittance beams. Superconducting RF guns combine the excellent vacuum conditions of the DC guns with the higher accelerating gradients of the RF guns and provide potentially a long lived cathode with very low transverse and longitudinal emittance. In our work at BNL, we successfully activated the GaAs. The quantum efficient is 3% at 532 nm and is expected

  16. Quantum efficiency temporal response and lifetime of a GaAs cathode in SRF electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.; Burrill, A.; Rao, T.; Wu, Q.; Holmes, D.

    2010-05-23

    RF electron guns with a strained super lattice GaAs cathode can generate polarized electron beam of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface. In a normal conducting RF gun, the extremely high vaccum required by these cathodes can not be met. We report on an experiment with a superconducting SRF gun, which can maintain a vacuum of nearly 10-12 torr because of cryo-pumping at the temperature of 4.2K. With conventional activation, we obtained a QE of 3% at 532 nm, with lifetime of nearly 3 days in the preparation chamber. We plan to use this cathode in a 1.3 GHz 1/2 cell SRF gun to study its performance. In addition, we studied the multipacting at the location of cathode. A new model based on the Forkker-Planck equation which can estimate the bunch length of the electron beam is discussed in this paper. Future particle accelerators such as eRHIC and ILC require high brightness, high current polarized electrons Recently, using a superlattice crystal, the maximum polarization of 95% was reached. Activation with Cs,O lowers the electron affinity and makes it energetically possible for all the electrons excited in to the conduction band and reach the surface to escape into the vacuum. Presently the polarized electron sources are based on DC gun, such as that at the CEBAF at Jlab. In these devices, the life time of the cathode is extended due to the reduced back bombardment in their UHV conditions. However, the low accelerating gradient of the DC guns lead to poor longitudinal emittance. The higher accelerating gradient of the RF gun generates low emittance beams. Superconducting RF guns combine the excellent vacuum conditions of the DC guns with the higher accelerating gradients of the RF guns and provide potentially a long lived cathode with very low transverse and longitudinal emittance. In our work at BNL, we successfully activated the GaAs. The quantum efficient is 3% at 532 nm and is

  17. Thermal Decomposition Characteristics of Orthorhombic Ammonium Perchlorate (o-AP) and an 0-AP/HTPB-Based Propellant

    International Nuclear Information System (INIS)

    BEHRENS JR., RICHARD; MINIER, LEANNA M.G.

    1999-01-01

    A study to characterize the low-temperature reactive processes for o-AP and an AP/HTPB-based propellant (class 1.3) is being conducted in the laboratory using the techniques of simultaneous thermogravimetric modulated beam mass spectrometry (STMBMS) and scanning electron microscopy (SEM). The results presented in this paper are a follow up of the previous work that showed the overall decomposition to be complex and controlled by both physical and chemical processes. The decomposition is characterized by the occurrence of one major event that consumes up to(approx)35% of the AP, depending upon particle size, and leaves behind a porous agglomerate of AP. The major gaseous products released during this event include H(sub 2)O, O(sub 2), Cl(sub 2), N(sub 2)O and HCl. The recent efforts provide further insight into the decomposition processes for o-AP. The temporal behaviors of the gas formation rates (GFRs) for the products indicate that the major decomposition event consists of three chemical channels. The first and third channels are affected by the pressure in the reaction cell and occur at the surface or in the gas phase above the surface of the AP particles. The second channel is not affected by pressure and accounts for the solid-phase reactions characteristic of o-AP. The third channel involves the interactions of the decomposition products with the surface of the AP. SEM images of partially decomposed o-AP provide insight to how the morphology changes as the decomposition progresses. A conceptual model has been developed, based upon the STMBMS and SEM results, that provides a basic description of the processes. The thermal decomposition characteristics of the propellant are evaluated from the identities of the products and the temporal behaviors of their GFRs. First, the volatile components in the propellant evolve from the propellant as it is heated. Second, the hot AP (and HClO(sub 4)) at the AP-binder interface oxidize the binder through reactions that

  18. A handheld low temperature atmospheric pressure air plasma gun for nanomaterial synthesis in liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Shuang; Wang, Kaile; Zuo, Shasha; Liu, Jiahui [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Zhang, Jue, E-mail: zhangjue@pku.edu.cn; Fang, Jing [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); College of Engineering, Peking University, Beijing 100871 (China)

    2015-10-15

    A handheld low temperature atmospheric pressure air plasma gun based on a dielectric barrier structure with hollow electrodes was proposed. The portable plasma gun with an embedded mini air pump was driven by a 12 V direct voltage battery. The air plasma jet generated from the gun could be touched without a common shock hazard. Besides working in air, the plasma gun can also work in water. The diagnostic result of optical emission spectroscopy showed the difference in reactive species of air plasma jet between in air and in water. The plasma gun was excited in 20 ml chloroauric acid aqueous solution with a concentration of 1.214 mM. A significant amount of gold nanoparticles were synthesized after 2 min continuous discharge. The plasma gun with these unique features is applicable in plasma medicine, etching, and s-nthesis of nanomaterials.

  19. New Horizons for Lipoprotein ReceptorsCommunication by β-propellers

    DEFF Research Database (Denmark)

    Andersen, Olav Michael; Dagil, Robert; Kragelund, Birthe B

    2013-01-01

    , this dogma has transformed with the observation that β-propellers of some LRs actively engage in complex formation too. Based on an in-depth decomposition of current structures and sequences, we suggest that exploitation of the β-propellers as binding targets depends on receptor subgroups. In particular, we...

  20. Progress of flame gunning materials; Yosha hoshuzai no shinpo

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Kakuichi [Harima Ceramic Corp., Hyogo (Japan)

    1999-04-01

    This report concerns to progress in the thermal spraying for repairing refractory, to say more precisely the flame-gunning materials. Gunning method using wet-slurry materials, in spite of its simplicity in execution, possesses a shortcoming of forming the porous deposit around spraying spot. Contrarily, the flame-gunning method is becoming popular in Japan because this method provides us with the minutely organized deposit having high tenacity and corrosion-resisting property. Flame is made from propane/oxygen mixture to assure the efficient melting of powdered clay. Magnesia/Dromite/slag system is preferable to converter furnace to produce a deposit layer less than 10% porosity. Materials based on alumina are preferable, although giving a relatively elevated porosity, to vacuum degassing vessel, converter furnace of stainless steel, hot stove for blast furnace, etc. Silca-rich system is characterized by the resistivity to recycled thermal procedure which brings about application to coke furnace. (NEDO)

  1. PHERMEX electron gun development

    International Nuclear Information System (INIS)

    Builta, L.A.; Elliott, J.C.; Moir, D.C.; Starke, T.P.; Vecere, C.A.

    1983-01-01

    The PHERMEX facility is a 50-MHz standing-wave linear accelerator. Electrons are injected, accelerated, and transported to a tungsten target where bremsstrahlung x rays are generated for flash radiography of hydrodynamic systems. The purpose of this article is to describe the progress of PHERMEX electron gun development. The goal of this program is to generate and transport a 200-ns, 1-MV, 1-kA electron beam into the first PHERMEX accelerating cavity. The standard gun is operated at a pulse voltage of 550 kV, which is the limit determined by internal breakdown of the vacuum insulator. This insulator has been redesigned, and the gun has been pulsed at 750 kV without internal breakdown. At present, the current output is not limited by voltage but by a phenomenon called pulse shortening, which occurs at a pulse voltage of approximately 650 kV. The phenomenon has been investigated and the results are presented

  2. What is the level of household gun ownership in urban Mexico? An estimate from the first Mexican survey on gun ownership 2017.

    Science.gov (United States)

    Perez Esparza, David; Hemenway, David

    2017-12-20

    Gun violence has increased in Mexico since the mid-2000s, but little is known about patterns of gun ownership. We examine the size and composition of the privately held urban firearm stock in Mexico, motivations for ownership, and attitudes about gun laws. To this end, a household telephone survey of 1361 adults living in nine Mexican cities was conducted in the summer of 2017. We find that few urban Mexican households contain guns. Most of those who report ownership possess one gun, having purchased it recently for self-defense. Few urban Mexican citizens plan to purchase a gun in the future. Respondents are more likely to believe that crime in Mexico would increase if guns were allowed in more places (ie, workplaces and motor vehicles). Evidence suggests urban Mexico has relative low rates of firearm ownership. Few city dwellers plan on obtaining a firearm in the near future. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Electrothermal plasma gun as a pellet injector

    International Nuclear Information System (INIS)

    Kincaid, R.W.; Bourham, M.A.

    1994-01-01

    The NCSU electrothermal plasma gun SIRENS has been used to accelerate plastic (Lexan polycarbonate) pellets, to determine the feasibility of the use of electrothermal guns as pellet injectors. The use of an electrothermal gun to inject frozen hydrogenic pellets requires a mechanism to provide protective shells (sabots) for shielding the pellet from ablation during acceleration into and through the barrel of the gun. The gun has been modified to accommodate acceleration of the plastic pellets using special acceleration barrels equipped with diagnostics for velocity and position of the pellet, and targets to absorb the pellet's energy on impact. The length of the acceleration path could be varied between 15 and 45 cm. The discharge energy of the electrothermal gun ranged from 2 to 6 kJ. The pellet velocities have been measured via a set of break wires. Pellet masses were varied between 0.5 and 1.0 grams. Preliminary results on 0.5 and 1.0 g pellets show that the exit velocity reaches 0.9 km/s at 6 kJ input energy to the source. Higher velocities of 1.5 and 2.7 km/s have been achieved using 0.5 and 1.0 gm pellets in 30 cm long barrel, without cleaning the barrel between the shots

  4. The Versatility of Perforator-Based Propeller Flap for Reconstruction of Distal Leg and Ankle Defects

    Directory of Open Access Journals (Sweden)

    Durga Karki

    2012-01-01

    Full Text Available Introduction. Soft tissue coverage of distal leg and ankle region represents a challenge and such defect usually requires a free flap. However, this may lead to considerable donor site morbidity, is time consuming, and needs facility of microsurgery. With the introduction of perforator flap, management of small- and medium-size defects of distal leg and ankle region is convenient, less time consuming, and with minimal donor site morbidity. When local perforator flap is designed as propeller and rotated to 180 degree, donor site is closed primarily and increases reach of flap, thus increasing versatility. Material and Methods. From June 2008 to May 2011, 20 patients were treated with perforator-based propeller flap for distal leg and ankle defects. Flap was based on single perforator of posterior tibial and peroneal artery rotated to 180 degrees. Defect size was from 4 cm × 3.5 cm to 7 cm × 5 cm. Results. One patient developed partial flap necrosis, which was managed with skin grafting. Two patients developed venous congestion, which subsided spontaneously without complications. Small wound dehiscence was present in one patient. Donor site was closed primarily in all patients. Rest of the flaps survived well with good aesthetic results. Conclusion. The perforator-based propeller flap for distal leg and ankle defects is a good option. This flap design is safe and reliable in achieving goals of reconstruction. The technique is convenient, less time consuming, and with minimal donor site morbidity. It provides aesthetically good result.

  5. 78 FR 11902 - Review of Gun Safety Technologies

    Science.gov (United States)

    2013-02-20

    ... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1615] Review of Gun Safety...'s Plan to reduce gun violence released on January 16, 2013, the U.S. Department of Justice, Office... emerging gun safety technologies and plans to issue a report on the availability and use of those...

  6. Gun Access and Safety Practices among Older Adults

    Directory of Open Access Journals (Sweden)

    Hillary D. Lum

    2016-01-01

    Full Text Available Background. Given high rates of gun ownership among older adults, geriatric providers can assess firearm safety practices using a “5 Ls” approach: Locked; Loaded; Little children; feeling Low; and Learned owner. This study describes gun access and the “5 Ls” among US older adults. Methods. Data on the “5 Ls” from the Second Injury Control and Risk Survey (ICARIS-2, a national telephone survey conducted by the Centers for Disease Control and Prevention, were analyzed. Weighted variables were used to generate national estimates regarding prevalence of gun ownership and associated gun safety among older adults (≥55 years. Results. Of 2939 older adults, 39% (95% CI 37%–42% reported ≥1 gun stored at home. Among those with guns at home, 21% (95% CI 18–24% stored guns loaded and unlocked; 9.2% (95% CI 6.6–12% had ≥1 child in household; 5.1% (95% CI 3.5–6.8% reported past-year suicidal ideation and 3.6% (95% CI 2.1–5.2% reported history of a suicide attempt; and 55% (95% CI 51–59% stated that ≥1 adult had attended firearm safety workshop. Conclusion. Some older adults may be at elevated risk of firearm injury because of storage practices, suicidal thoughts, or limited safety training. Future work should assess effective approaches to reduce the risk of gun-related injuries among older adults.

  7. A 3 GHz photoelectron gun for high beam intensity

    CERN Document Server

    Bossart, Rudolf; Dehler, M; Godot, J C

    1996-01-01

    For the Compact Linear Collider Test Facility (CTF) at CERN a new rf gun with a laser driven photocathode is under construction. The new rf gun will replace the present 11/2 cell gun and will consist of 21/2 cells accelerating the beam to a momentum of 7.0 MeV/c with an electric field strength of 100 MV/m. The strong space-charge forces at low beam energy caused by the high charge density of the electron bunches are contained by radial and longitudinal rf focusing in the gun. The rf gun under construction has been optimized by MAFIA beam simulations for an injector assembly comprising a second accelerating rf structure and an intermediate solenoid magnet correcting the beam divergence of the 21/2 cell gun. The beam loading of the rf gun, by a train of 48 bunches with 21 nC charge each, causes a strong energy decay accompanied by an increase of the flight time for the bunches with lower energy. These effects can be corrected by slightly shifting the acceleration frequency of the gun. The experimental results...

  8. Utility of indices of gun availability in the community.

    Science.gov (United States)

    Shenassa, Edmond D; Daskalakis, Constantine; Buka, Stephen L

    2006-01-01

    To estimate the degree to which the proportion of homicides and suicides committed with a gun is associated with reported availability of firearms across Chicago neighbourhoods. Data were collected as part of the Project on Human Development in Chicago Neighborhoods (PHDCN), a combined neighbourhood and individual level study of the city of Chicago. The study used data from 837 PHDCN participants between the ages of 17 and 22, residing in 170 different neighbourhoods. Gun availability was measured via participant reports on whether they had carried a gun and whether they perceived gun access to be easy in their community. Data on suicides and homicides were obtained from the Chicago Department of Health. A 10% change in the proportion of homicides committed by a gun in a neighbourhood was associated with a 20% increase in both the odds of reported gun access and reported gun carrying (p=0.002 and 0.048, respectively). The proportion of firearm related suicides was not associated with either of those self reported measures. The proportion of firearm related homicides, but not the proportion of firearm related suicides, is a useful predictor of gun availability across small areas such as neighbourhoods.

  9. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R. E.; Maruyama, T.; Miller, R. H.; Wang, J. W.; Zhou, F.

    2007-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of ≥200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while ≥500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  10. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R.E.; Maruyama, T.; Miller, R.H.; Wang, J.W.; Zhou, F.; SLAC

    2006-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of (ge)200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while (ge)500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  11. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham M, Bruce; Heartmann, P.; Reza Kazimi; Hongxiu Liu; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair K, Charles

    1998-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughout. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion back-bombardment, and precise control of all of the electrons emitted from the cathode. In this paper, the authors will review recent results and discuss implications for future photocathode guns

  12. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B. M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B. M.; Price, J. S.; Rutt, P. M.; Schneider, W. J.; Sinclair, C. K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns

  13. A compact electron gun using field emitter array

    International Nuclear Information System (INIS)

    Asakawa, M.R.; Ikeda, A.; Miyabe, N.; Yamaguchi, S.; Kusaba, M.; Tsunawaki, Y.

    2008-01-01

    A compact electron gun using field emitter array has been developed. With a simple triode configuration consisting of FEA, mid-electrode and anode electrode, the electron gun produces a parallel beam with a diameter of 0.5 mm. This electron gun is applicable for compact radiation sources such as Cherenkov free-electron lasers

  14. Development of the electron gun control system of SSRF

    International Nuclear Information System (INIS)

    Zhou Dayong; Lin Guoqiang; Liu Dekang; Shen Liren

    2010-01-01

    An electron gun is the key part of a linac, the beam quality of which depends on beam quality of the electron gun, hence the need of a stable control system of the electron gun to ensure its safe operation.In this paper, we report our progresses in developing the linac's electron gun control system of Shanghai Synchrotron Radiation Facility (SSRF). It uses PLC as the device controllers, with the monitoring software developed on EPICS. The whole system is connected by Ethernet. The PLC and Ethernet technology ensures good reliability and easy maintenance of the electron gun control system. (authors)

  15. Spheromak experiment using separate guns for formation and sustainment

    International Nuclear Information System (INIS)

    Brown, M.R.; Martin, A.

    1996-01-01

    An experiment is described that incorporates the use of separate magnetized plasma guns for formation and sustainment of a spheromak. It is shown that energy coupling efficiency approaches unity if the gun and spheromak are of comparable size. A large gun should be able to operate at lower current and therefore lower voltage. In addition, it is expected that a gun matched to the size of the spheromak will cause less perturbation to the equilibrium. It is proposed to use a smaller gun for spheromak formation and a large, efficient gun for sustainment. The theoretical basis for the experiment is developed, and the details of the experiment are described. A prediction of the equilibrium magnetic flux surfaces using the EFIT code is presented. 28 refs., 3 figs., 1 tab

  16. Recent advances in high-brightness electron guns at AES

    International Nuclear Information System (INIS)

    Bluem, H.; Todd, A.M.M.; Cole, M.D.; Rathke, J.; Schultheiss, T.

    2003-01-01

    We describe a number of active Advanced Energy Systems projects pertaining to the development of advanced, high-brightness electron guns for various applications. These projects include a fully superconducting, CW RF gun, nearing test, that utilizes the niobium surface as the photocathode material. An integrated 100 mA, low emittance DC/SRF gun, ideal as an injector for ERL-type light sources and intended as the injector for a 100 kW FEL, is in late design stage. A parallel high-power, CW, normal-conducting L-band RF gun project has just begun. The early performance analysis for this gun also shows good promise as an injector for ERL-type light sources. Lastly, a fully axisymmetric RF gun, operating in X-band, is being studied as a source of extremely bright electron bunches

  17. Particle transport and gas feed during gun injection

    International Nuclear Information System (INIS)

    Fowler, T K.

    1999-01-01

    It is shown that ion and neutral transport during gun injection tends to equalize the density in the spheromak to that in the open-line current channel. Since a gun operating at or near the ion saturation current requires a minimum density, because of transport these gun requirements also determine a minimum density in the spheromak that increases as the field increases. Hence attaining high fields by gun injection sets lower limits on the density, which in turn limits the temperature of the plasma and increases its ohmic resistance. Estimates of these effects are given using 0-D models calibrated to CTX, as guidance to 2-D UEDGE calculations in progress. For gun power levels in SSPX and the Pulsed Spheromak reactor, we find that buildup persists to the highest field levels of interest

  18. Development of a novel thermionic RF electron gun applied on a compact THz-FEL facility

    Science.gov (United States)

    Hu, T. N.; Pei, Y. J.; Qin, B.; Liu, K. F.; Feng, G. Y.

    2018-04-01

    The current requirements from civil and commercial applications lead to the development of compact free-electron laser (FEL)-based terahertz (THz) radiation sources. A picosecond electron gun plays an important role in an FEL-THz facility and attracts significant attention, as machine performance is very sensitive to initial conditions. A novel thermionic gun with an external cathode (EC) and two independently tunable cavities (ITCs) has been found to be a promising alternative to conventional electron sources due to its remarkable characteristics, and correspondingly an FEL injector can achieve a balance between a compact layout and high brightness benefitting from the velocity bunching properties and RF focusing effects in the EC-ITC gun. Nevertheless, the EC-ITC gun has not been extensively examined as part of the FEL injector in the past years. In this regard, to fill this gap, a development focusing on the experimental setup of an FEL injector based on an EC-ITC gun is described in detail. Before assembly, dynamic beam simulations were performed to investigate the optimal mounting position for the Linac associated with the focusing coils, and a suitable radio-frequency (RF) system was established based on a power coupling design and allocation. The testing bench proved to be fully functional through basic experiments using typical diagnostic approaches for estimating primary parameters. Associated with dynamic beam calculations, a performance evaluation for an EC-ITC gun was established while providing indirect testing results for an FEL injector.

  19. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  20. Lasers for RF guns: Proceedings

    International Nuclear Information System (INIS)

    Srinivasan-Rao, T.

    1994-01-01

    In the past decade, laser driven RF guns have matured from a device under development to a proven source for high brightness and low emittance electron beams. The reliability of the electron beam from these sources is dictated by the laser system that drives it. In addition, capabilities of the laser systems play a vital role in the design of the electron source for future machines such as the TESLA and NLC. The purpose of this workshop was to provide a forum for discussing the design criteria for the laser systems so that the reliability of the existing sources could be improved and the future machines could be serviced. The Workshop brought together experts in RF Guns, accelerators, and lasers, from both the commercial and academic community. Most of the presentations, discussions and conclusions at the workshop are included in these proceedings. The contents are divided into three sections, Section I contains the invited talks that outline the requirements of the RF Guns and the capabilities of the laser systems to meet these requirements. Section II includes most of the papers presented in the poster session. These papers describe various laser systems used with electron guns, schemes to modify the laser beam profile to optimize the electron bunch, and computer simulations of electron trajectories. Section III contains the summaries of the working groups. As the summary section indicates, with sufficient feed back systems, the electron gun could be made to operate reliably with minimum downtime, using commercial lasers currently available. The design of laser systems for future colliders depend critically on the choice of the cathode m the gun and its efficiency. Tentative designs of laser systems for the TESLA test facility and LCLS had been drawn assuming a copper cathode. Using a more efficient cathode will ease the energy requirement of the laser and simplify the design. The individual papers have been cataloged separately elsewhere

  1. Development of the Antares electron gun

    International Nuclear Information System (INIS)

    Stine, R.; Leland, W.; Mansfield, C.; Rosocha, L.; Jansen, J.; Gibson, R.; Allen, G.

    1984-01-01

    Antares is the Los Alamos National Laboratory 40-kJ, 1-ns, CO 2 laser system that is now operational. This laser system was developed for the Intertial Confinement Fusion (ICF) program and is beginning target experiments. The distributed circuit modeling, design and operation of the large electron gun developed for the final laser power amplifier are reviewed. This gun is significant because of the large electron current area, 9 m 2 ; the number of emitter blades, 48; the dual cathode current return; and the coaxial geometry and grid control. The gun components and their development are discussed. These include the emitter blades, the coaxial grid (to maintain constant electron current during the 5-μs pulse), the bonded stacked-ring insulator (to electrically insulate the grid/cathode), the Kapton/aluminum electron transmission windows (to provide an interface between gun vacuum and laser gas) and the vacuum shell (operated at a vacuum of 10 -6 torr). A unique pressure diagnostic is also discussed

  2. College Students Opinions on Gun Violence.

    Science.gov (United States)

    Lewis, Rhonda K; LoCurto, Jamie; Brown, Kyrah; Stowell, David; Maryman, J'Vonnah; Dean, Amber; McNair, Thoi; Ojeda, Debbie; Siwierka, Julia

    2016-06-01

    Gun violence and control issues have become serious public health problems. This study gathered the opinions from 419 college students from a Midwestern University. Participants were asked about beliefs about purchasing assault weapons, beliefs about bringing handguns to college campuses and beliefs about contributing factors that lead to gun violence. Participants completed surveys online. The findings showed that overall 54 % of respondents believed that military assault weapons should be banned and 53 % agree that teachers should be allowed to carry a registered handgun on campus. There were statistically significant differences between males and females on these issues. For instance, females believed military assault weapons and high capacity magazines should be banned more than 1.9 times (p = .004) p gun violence were decline in parenting and family values (17 %), gang involvement (14 %), bullying (13.8 %) and guns being easy to obtain (13.8 %). Limitations and implications for policy work are discussed.

  3. Human health risks from TNT, RDX, and HMX in environmental media and consideration of the US Regulatory Environment

    International Nuclear Information System (INIS)

    Daniels, J.I.; Knezovich, J.P.

    1994-12-01

    Although the most economical method for disposing of unwanted energetic high explosives [HEs; e.g., 2,4,6-trinitrotoluene (TNT), hexahydro-1,3,5-trinitro-triazine (RDX, also known as Cyclonite), and octahydro-1,3,5,7-tetrazocine (HMX, also known as Octogen)] involves open burning and open or underground detonation [OB/O(U)D]; federal, state, and even local government agencies in the United States (U.S.) are implementing stricter environmental regulations that eventually may prevent such activities. These stricter regulations will promote alternative technologies that are designed to be environmentally benign. However, past HE-waste disposal practices at manufacturing and fabrication facilities in the U.S. have included uncontrolled OB/O(U)D, as well as direct surface discharge of HE-contaminated waste water, resulting in contaminated environmental media (e.g., ground water, soil, and perhaps even edible vegetation) near residential areas. Using TNT, RDX, and HMX as examples, this paper describes how risk-based standards for HEs can be derived that account for potential multimedia exposures (associated with contaminated air, water, food, and soil) by individuals near a contaminated site, and used to (1) protect public health and safety; (2)prevent limited resources from being dedicated to unnecessary cleanup activities; and (3) identify the most cost-effective, practical, and environmentally benign technologies suitable for integrating with the handling of the large quantity of high explosives scheduled for demilitarization

  4. rf traveling-wave electron gun for photoinjectors

    Science.gov (United States)

    Schaer, Mattia; Citterio, Alessandro; Craievich, Paolo; Reiche, Sven; Stingelin, Lukas; Zennaro, Riccardo

    2016-07-01

    The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL) machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least) double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  5. Strong gun laws are not enough: the need for improved enforcement of secondhand gun transfer laws in Massachusetts.

    Science.gov (United States)

    Braga, Anthony A; Hureau, David M

    2015-10-01

    Research suggests that an overwhelming majority of crime guns were transferred by private sellers before recovery by law enforcement. Unfortunately, most states do not regulate these transactions. This study examines whether analyses of state-level private transfer data could be used to develop interventions to reduce the supply of handguns to violent criminals. Traced Boston crime handguns first sold at Massachusetts license dealers were matched to state secondhand gun transfer data. Logistic regression and descriptive statistics were used to analyze the characteristics of recovered crime guns and in-state primary and secondary market transaction patterns. For crime handguns with records of secondary market transactions in Massachusetts, many rapidly move from private transfer to recovery by the police. Unfortunately, important transaction data on the in-state sources of nearly 63% of recovered handguns were not readily available to law enforcement agencies. Data on private transfers of guns could be used to prevent violent injuries by reducing criminal access. However, the passage of strong private transfer gun laws needs to be accompanied by investments in the vigorous enforcement of reporting requirements. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Improvement in energy release properties of boron-based propellant by oxidant coating

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Daolun; Liu, Jianzhong, E-mail: jzliu@zju.edu.cn; Chen, Binghong; Zhou, Junhu; Cen, Kefa

    2016-08-20

    Highlights: • NH{sub 4}ClO{sub 4}, KNO{sub 3}, KClO{sub 4} and HMX coated B were used to prepare propellant samples. • FTIR, XRD and SEM were used for the microstructure analysis of the prepared B. • Thermal oxidation and combustion characteristics of the propellants were studied. • HMX coating was the most beneficial to the energy release of the samples. - Abstract: The energy release properties of a propellant can be improved by coating boron (B) particles with oxidants. In the study, B was coated with four different oxidants, namely, NH{sub 4}ClO{sub 4}, KNO{sub 3}, LiClO{sub 4}, and cyclotetramethylenetetranitramine (HMX), and the corresponding propellant samples were prepared. First, the structural and morphological analyses of the pretreated B were carried out. Then, the thermal analysis and laser ignition experiments of the propellant samples were carried out. Coating with NH{sub 4}ClO{sub 4} showed a better performance than mechanical mixing with the same component. Coating with KNO{sub 3} efficiently improved the ignition characteristics of the samples. Coating with LiClO{sub 4} was the most beneficial in reducing the degree of difficulty of B oxidation. Coating with HMX was the most beneficial in the heat release of the samples. The KNO{sub 3}-coated sample had a very high combustion intensity in the beginning, but then it rapidly became weak. Large amounts of sparks were ejected during the combustion of the LiClO{sub 4}-coated sample. The HMX-coated sample had the longest self-sustaining combustion time (4332 ms) and the highest average combustion temperature (1163.92 °C).

  7. Long pulse, plasma cathode E-gun

    International Nuclear Information System (INIS)

    Goebel, D.M.; Schumacher, R.W.; Watkins, R.M.

    1993-01-01

    A unique, long-pulse E-gun has been developed for high-power tube applications. The Hollow-Cathode-Plasma (HCP) E-gun overcomes the limitations of conventional thermionic-cathode guns that have limited current density (typically ≤ 10 A/cm 2 ) or field-emission guns that offer high current density but suffer from short pulsewidth capability (typically 50 A/cm 2 ), long-pulse operation without gap closure, and also requires no cathode-heater power. The gun employs a low-pressure glow discharge inside a hollow cathode (HC) structure to provide a stable, uniform plasma surface from which a high current-density electron beam can be extracted. The plasma density is controlled by a low-voltage HC discharge pulser to produce the desired electron current density at the first grid of a multi-grid accelerator system. A dc high-voltage electron-beam supply accelerates the electrons across the gap, while the HC pulser modulates the beam current to generate arbitrary pulse waveforms. The electron accelerator utilizes a multi-aperture array that produces a large area, high perveance (>35 μpervs) beam consisting initially of many individual beamlets. The E-beam is normally operated without an applied magnetic field in the ion-focused regime, where the plasma produced by beam ionization of a background gas space-charge neutralizes the beam, and the Bennett self-pinch compresses the beamlets and increases the current density. The self-pinched beam has been observed to propagate over a meter without beam breakup or instabilities. The HCP E-gun has been operated at voltages up to 150 kV, currents up to 750 A, and pulse lengths of up to 120 μsec

  8. Cerenkov Radiator Driven by a Superconducting RF Electron Gun

    International Nuclear Information System (INIS)

    Poole, B.R.; Harris, J.R.

    2011-01-01

    The Naval Postgraduate School (NPS), Niowave, Inc., and Boeing have recently demonstrated operation of the first superconducting RF electron gun based on a quarter wave resonator structure. In preliminary tests, this gun has produced 10 ps long bunches with charge in excess of 78 pC, and with beam energy up to 396 keV. Initial testing occurred at Niowave's Lansing, MI facility, but the gun and diagnostic beam line are planned for installation in California in the near future. The design of the diagnostic beam line is conducive to the addition of a Cerenkov radiator without interfering with other beam line operations. Design and simulations of a Cerenkov radiator, consisting of a dielectric lined waveguide will be presented. The dispersion relation for the structure is determined and the beam interaction is studied using numerical simulations. The characteristics of the microwave radiation produced in both the short and long bunch regimes will be presented.

  9. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5-Triazine (RDX) (External Review Draft)

    Science.gov (United States)

    The IRIS Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was released for external peer review in September 2016. The EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis suppor...

  10. A simple model of the plasma deflagration gun including self-consistent electric and magnetic fields

    International Nuclear Information System (INIS)

    Enloe, C.L.; Reinovsky, R.E.

    1985-01-01

    At the Air Force Weapons Laboratory, interest has continued for some time in energetic plasma injectors. A possible scheme for such a device is the plasma deflagration gun. When the question arose whether it would be possible to scale a deflagration gun to the multi-megajoule energy level, it became clear that a scaling law which described the fun as a circuit element and allowed one to confidently scale gun parameters would be required. The authors sought to develop a scaling law which self-consistently described the current, magnetic field, and velocity profiles in the gun. They based this scaling law on plasma parameters exclusively, abandoning the fluid approach

  11. Gun Carrying by High School Students in Boston, MA: Does Overestimation of Peer Gun Carrying Matter?

    Science.gov (United States)

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M.; Miller, Matthew; Azrael, Deborah

    2011-01-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1700 high school students in Boston, MA. Over 5% of students reported carrying a…

  12. The PLX- α Plasma Guns: Progress and Plans

    Science.gov (United States)

    Witherspoon, F. D.; Brockington, S.; Case, A.; Cruz, E.; Luna, M.; Thio, Y. C. Francis; LANL PLX-α Team

    2017-10-01

    The ALPHA coaxial plasma guns are being developed to support a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). Seven complete guns have been delivered to LANL with 6 guns currently undergoing simultaneous test firings on PLX. The guns are designed to operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured coaxial gap to suppress the blow-by instability. Optimizing parameter scans performed at HyperV have achieved : 4 mg at >50 km/s and length of 10 cm. Peak axial density 30 cm from the muzzle is 2 ×1016 cm-3. We will provide an overview of the experimental results, along with plans for further improvements in reliability, maintainability, fabricability, and plasma jet performance, with the latter focused on further improvements in the fast gas valve and the ignitors. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  13. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B.M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair, C.K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns. copyright 1999 American Institute of Physics

  14. The polarized electron gun for the SLC

    International Nuclear Information System (INIS)

    Schultz, D.C.; Clendenin, J.; Frisch, J.; Hoyt, E.; Klaisner, L.; Woods, M.; Wright, D.; Zolotorev, M.

    1992-03-01

    A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown

  15. Development of a hydrogen electrothermal accelerator for plasma fueling

    International Nuclear Information System (INIS)

    Schuresko, D.D.; Milora, S.L.; Combs, S.K.; Foust, C.R.; Argo, B.E.; Barber, G.C.; Foster, C.A.; Ponte, N.S.

    1986-01-01

    We have developed a prototype high velocity pneumatic pellet injector which utilizes hydrogen plasma propellant generated in a high current arc discharge. A single barrel pneumatic pellet gun has been fitted with a cylindrical arc chamber interposed between the hydrogen propellant inlet valve and the gun breech. The chamber incorporates a ceramic insert for generating vortex flow in the incoming gas stream, which provides azimuthal arc stabilization. The arc is initiated after the propellant valve opens and the breech pressure starts to rise; a typical discharge lasts 150-300 microseconds with peak currents up to 2 kA. The gun has been operated with 4mm diameter by 6 to 11 mm long deuterium and hydrogen pellets. At 100 bar breech pressure (hydrogen propellant), the arc characteristics are = 350 to 800 V, = 600 A, so that 60 to 150 joules of electrical power is dissipated. Pellet speeds increase by 300 to 500 m/s depending on the projectile mass, which typically represents a 10 joule increment in the pellet kinetic energy. Velocities up to 1.7 km/s for deuterium pellets and 2.0 km/s for hydrogen pellets have been achieved. Comparing these data to muzzle velocities calculated from lossless, one-dimensional compressible flow gun theory demonstrates that substantial propellant heating, resulting in increased propellant sound speed, has been achieved

  16. Tri-Service Green Gun Barrel (PP 1074)

    National Research Council Canada - National Science Library

    Rusch, Lawrence F

    2003-01-01

    ...) PP 1074 Tri-Service Green Gun Barrel. The program's goal was to develop an environmentally friendly process for depositing wear and erosion resistant materials onto gun bores replacing the current hazardous aqueous electro-deposition...

  17. Progress on a cryogenically cooled RF gun polarized electron source

    Energy Technology Data Exchange (ETDEWEB)

    Fliller, R.P., III; Edwards, H.; /Fermilab

    2006-08-01

    RF guns have proven useful in multiple accelerator applications. An RF gun capable of producing polarized electrons is an attractive electron source for the ILC or an electron-ion collider. Producing such a gun has proven elusive. The NEA GaAs photocathode needed for polarized electron production is damaged by the vacuum environment in an RF gun. Electron and ion back bombardment can also damage the cathode. These problems must be mitigated before producing an RF gun polarized electron source. In this paper we report continuing efforts to improve the vacuum environment in a normal conducting RF gun by cooling it with liquid nitrogen after a high temperature vacuum bake out. We also report on a design of a cathode preparation chamber to produce bulk GaAs photocathodes for testing in such a gun. Future directions are also discussed.

  18. Dependence of the firearm-related homicide rate on gun availability: a mathematical analysis.

    Directory of Open Access Journals (Sweden)

    Dominik Wodarz

    Full Text Available In the USA, the relationship between the legal availability of guns and the firearm-related homicide rate has been debated. It has been argued that unrestricted gun availability promotes the occurrence of firearm-induced homicides. It has also been pointed out that gun possession can protect potential victims when attacked. This paper provides a first mathematical analysis of this tradeoff, with the goal to steer the debate towards arguing about assumptions, statistics, and scientific methods. The model is based on a set of clearly defined assumptions, which are supported by available statistical data, and is formulated axiomatically such that results do not depend on arbitrary mathematical expressions. According to this framework, two alternative scenarios can minimize the gun-related homicide rate: a ban of private firearms possession, or a policy allowing the general population to carry guns. Importantly, the model identifies the crucial parameters that determine which policy minimizes the death rate, and thus serves as a guide for the design of future epidemiological studies. The parameters that need to be measured include the fraction of offenders that illegally possess a gun, the degree of protection provided by gun ownership, and the fraction of the population who take up their right to own a gun and carry it when attacked. Limited data available in the literature were used to demonstrate how the model can be parameterized, and this preliminary analysis suggests that a ban of private firearm possession, or possibly a partial reduction in gun availability, might lower the rate of firearm-induced homicides. This, however, should not be seen as a policy recommendation, due to the limited data available to inform and parameterize the model. However, the model clearly defines what needs to be measured, and provides a basis for a scientific discussion about assumptions and data.

  19. Dependence of the firearm-related homicide rate on gun availability: a mathematical analysis.

    Science.gov (United States)

    Wodarz, Dominik; Komarova, Natalia L

    2013-01-01

    In the USA, the relationship between the legal availability of guns and the firearm-related homicide rate has been debated. It has been argued that unrestricted gun availability promotes the occurrence of firearm-induced homicides. It has also been pointed out that gun possession can protect potential victims when attacked. This paper provides a first mathematical analysis of this tradeoff, with the goal to steer the debate towards arguing about assumptions, statistics, and scientific methods. The model is based on a set of clearly defined assumptions, which are supported by available statistical data, and is formulated axiomatically such that results do not depend on arbitrary mathematical expressions. According to this framework, two alternative scenarios can minimize the gun-related homicide rate: a ban of private firearms possession, or a policy allowing the general population to carry guns. Importantly, the model identifies the crucial parameters that determine which policy minimizes the death rate, and thus serves as a guide for the design of future epidemiological studies. The parameters that need to be measured include the fraction of offenders that illegally possess a gun, the degree of protection provided by gun ownership, and the fraction of the population who take up their right to own a gun and carry it when attacked. Limited data available in the literature were used to demonstrate how the model can be parameterized, and this preliminary analysis suggests that a ban of private firearm possession, or possibly a partial reduction in gun availability, might lower the rate of firearm-induced homicides. This, however, should not be seen as a policy recommendation, due to the limited data available to inform and parameterize the model. However, the model clearly defines what needs to be measured, and provides a basis for a scientific discussion about assumptions and data.

  20. Effects of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) metabolites on cricket (Acheta domesticus) survival and reproductive success

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Baohong [Institute of Environmental and Human Health (TIEHH), and Department of Environmental Toxicology, Texas Tech University, Box 41163, Lubbock, TX 79409-1163 (United States); Freitag, Christina M. [Institute of Environmental and Human Health (TIEHH), and Department of Environmental Toxicology, Texas Tech University, Box 41163, Lubbock, TX 79409-1163 (United States); Canas, Jaclyn E. [Institute of Environmental and Human Health (TIEHH), and Department of Environmental Toxicology, Texas Tech University, Box 41163, Lubbock, TX 79409-1163 (United States); Cheng Qiuqiong [Institute of Environmental and Human Health (TIEHH), and Department of Environmental Toxicology, Texas Tech University, Box 41163, Lubbock, TX 79409-1163 (United States); Anderson, Todd A. [Institute of Environmental and Human Health (TIEHH), and Department of Environmental Toxicology, Texas Tech University, Box 41163, Lubbock, TX 79409-1163 (United States)]. E-mail: todd.anderson@tiehh.ttu.edu

    2006-11-15

    The effect of two major hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) metabolites, hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX) and hexahydro-1,3,5-trinitroso-1,3,5-triazine (TNX), on cricket (Acheta domesticus) survival and reproduction was studied. RDX metabolites did not have adverse effects on cricket survival, growth, and egg production. However, MNX and TNX did affect egg hatching. MNX and TNX were more toxic in spiked-sand than in topical tests. TNX was more toxic to egg than MNX. Developmental stage and exposure time affected hatching. After 30 days exposure to MNX or TNX, the EC{sub 2}, EC{sub 5}, and EC{sub 95} were 47, 128, and 247 {mu}g/g for TNX, and 65, 140, and 253 {mu}g/g for MNX in topical tests. The ECs for 20, 50, and 95 were 21, 52, and 99 {mu}g/g for MNX, and 12, 48, and 97 {mu}g/g for TNX in sand. No gross abnormalities in cricket nypmhs were observed in all experiments indicating that neither TNX or MNX is teratogenic in this assay. - RDX metabolites did not have adverse effects on cricket survival, growth, and egg production, but adversely affected egg hatching.

  1. Effects of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) metabolites on cricket (Acheta domesticus) survival and reproductive success

    International Nuclear Information System (INIS)

    Zhang Baohong; Freitag, Christina M.; Canas, Jaclyn E.; Cheng Qiuqiong; Anderson, Todd A.

    2006-01-01

    The effect of two major hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) metabolites, hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX) and hexahydro-1,3,5-trinitroso-1,3,5-triazine (TNX), on cricket (Acheta domesticus) survival and reproduction was studied. RDX metabolites did not have adverse effects on cricket survival, growth, and egg production. However, MNX and TNX did affect egg hatching. MNX and TNX were more toxic in spiked-sand than in topical tests. TNX was more toxic to egg than MNX. Developmental stage and exposure time affected hatching. After 30 days exposure to MNX or TNX, the EC 2 , EC 5 , and EC 95 were 47, 128, and 247 μg/g for TNX, and 65, 140, and 253 μg/g for MNX in topical tests. The ECs for 20, 50, and 95 were 21, 52, and 99 μg/g for MNX, and 12, 48, and 97 μg/g for TNX in sand. No gross abnormalities in cricket nypmhs were observed in all experiments indicating that neither TNX or MNX is teratogenic in this assay. - RDX metabolites did not have adverse effects on cricket survival, growth, and egg production, but adversely affected egg hatching

  2. Stability and performance studies of the PITZ photoelectron gun

    Energy Technology Data Exchange (ETDEWEB)

    Isaev, Igor

    2018-02-15

    The invention of free electron lasers (FELs) opened new opportunities for the investigation of natural phenomena. However, the operation of a FEL requires high energy, high peak current electron beams with very small transverse emittance which causes extreme requirements for the corresponding electron sources. Besides the high beam quality, the electron sources must have very high operational stability and reliability. One of the electron source types which satisfy FEL requirements is a photoelectron gun. Photoelectron guns combine photoemissive electron generation and direct acceleration in a Radio Frequency (RF) cavity. The Photo Injector Test facility at DESY, Zeuthen site (PITZ), was established as a test stand of the electron source for FELs like FLASH and the European XFEL in Hamburg. The studies of the beam emittance at PITZ showed that the gun is able to produce electron beams with emittance even smaller than it is required by XFEL specifications. But the experiments on the emittance revealed discrepancies between expected gun behavior and observation, such as the difference in optimal parameters for the smallest emittance value, asymmetry of the transverse beam profile and the phase spaces. The work performed at PITZ includes preparation of several RF guns for their subsequent operation at FLASH and the European XFEL. RF conditioning of a gun cavity is one of the major steps of the preparation of a high brightness electron source required for modern FELs. A thorough procedure is applied to increase the peak and average RF power in the gun cavity, including an increase of the repetition rate and RF pulse length combined with a gun solenoid current sweep. The main goals of this thesis are: (1) an attempt of deep understanding of physical processes taking place during operation of a photoelectron gun (conditioning process, parameters adjustments); (2) definition of operational problems sources and explanation of the experimentally obtained results in the gun

  3. Stability and performance studies of the PITZ photoelectron gun

    International Nuclear Information System (INIS)

    Isaev, Igor

    2018-02-01

    The invention of free electron lasers (FELs) opened new opportunities for the investigation of natural phenomena. However, the operation of a FEL requires high energy, high peak current electron beams with very small transverse emittance which causes extreme requirements for the corresponding electron sources. Besides the high beam quality, the electron sources must have very high operational stability and reliability. One of the electron source types which satisfy FEL requirements is a photoelectron gun. Photoelectron guns combine photoemissive electron generation and direct acceleration in a Radio Frequency (RF) cavity. The Photo Injector Test facility at DESY, Zeuthen site (PITZ), was established as a test stand of the electron source for FELs like FLASH and the European XFEL in Hamburg. The studies of the beam emittance at PITZ showed that the gun is able to produce electron beams with emittance even smaller than it is required by XFEL specifications. But the experiments on the emittance revealed discrepancies between expected gun behavior and observation, such as the difference in optimal parameters for the smallest emittance value, asymmetry of the transverse beam profile and the phase spaces. The work performed at PITZ includes preparation of several RF guns for their subsequent operation at FLASH and the European XFEL. RF conditioning of a gun cavity is one of the major steps of the preparation of a high brightness electron source required for modern FELs. A thorough procedure is applied to increase the peak and average RF power in the gun cavity, including an increase of the repetition rate and RF pulse length combined with a gun solenoid current sweep. The main goals of this thesis are: (1) an attempt of deep understanding of physical processes taking place during operation of a photoelectron gun (conditioning process, parameters adjustments); (2) definition of operational problems sources and explanation of the experimentally obtained results in the gun

  4. The design of gridded pierce guns for accelerators

    International Nuclear Information System (INIS)

    True, R.

    1985-01-01

    It is vital to employ ultra-laminar beams in electron linacs to maximize charge transport to the target. This paper presents numerical and experimental design techniques which have led to significant improvements in gridded Pierce guns used in microwave tubes and electron linacs. The paper concludes with two gun/injector concepts which have demonstrated enhanced performance over standard triode Pierce guns

  5. Development of plasma cathode electron guns

    Science.gov (United States)

    Oks, Efim M.; Schanin, Peter M.

    1999-05-01

    The status of experimental research and ongoing development of plasma cathode electron guns in recent years is reviewed, including some novel upgrades and applications to various technological fields. The attractiveness of this kind of e-gun is due to its capability of creating high current, broad or focused beams, both in pulsed and steady-state modes of operation. An important characteristic of the plasma cathode electron gun is the absence of a thermionic cathode, a feature which leads to long lifetime and reliable operation even in the presence of aggressive background gas media and at fore-vacuum gas pressure ranges such as achieved by mechanical pumps. Depending on the required beam parameters, different kinds of plasma discharge systems can be used in plasma cathode electron guns, such as vacuum arcs, constricted gaseous arcs, hollow cathode glows, and two kinds of discharges in crossed E×B fields: Penning and magnetron. At the present time, plasma cathode electron guns provide beams with transverse dimension from fractional millimeter up to about one meter, beam current from microamperes to kiloamperes, beam current density up to about 100 A/cm2, pulse duration from nanoseconds to dc, and electron energy from several keV to hundreds of keV. Applications include electron beam melting and welding, surface treatment, plasma chemistry, radiation technologies, laser pumping, microwave generation, and more.

  6. Heterogeneous propellant internal ballistics: criticism and regeneration

    Science.gov (United States)

    Glick, R. L.

    2011-10-01

    Although heterogeneous propellant and its innately nondeterministic, chemically discrete morphology dominates applications, ballisticcharacterization deterministic time-mean burning rate and acoustic admittance measures' absence of explicit, nondeterministic information requires homogeneous propellant with a smooth, uniformly regressing burning surface: inadequate boundary conditions for heterogeneous propellant grained applications. The past age overcame this dichotomy with one-dimensional (1D) models and empirical knowledge from numerous, adequately supported motor developments and supplementary experiments. However, current cost and risk constraints inhibit this approach. Moreover, its fundamental science approach is more sensitive to incomplete boundary condition information (garbage-in still equals garbage-out) and more is expected. This work critiques this situation and sketches a path forward based on enhanced ballistic and motor characterizations in the workplace and approximate model and apparatus developments mentored by CSAR DNS capabilities (or equivalent).

  7. Cryogenic Propellant Feed System Analytical Tool Development

    Science.gov (United States)

    Lusby, Brian S.; Miranda, Bruno M.; Collins, Jacob A.

    2011-01-01

    The Propulsion Systems Branch at NASA s Lyndon B. Johnson Space Center (JSC) has developed a parametric analytical tool to address the need to rapidly predict heat leak into propellant distribution lines based on insulation type, installation technique, line supports, penetrations, and instrumentation. The Propellant Feed System Analytical Tool (PFSAT) will also determine the optimum orifice diameter for an optional thermodynamic vent system (TVS) to counteract heat leak into the feed line and ensure temperature constraints at the end of the feed line are met. PFSAT was developed primarily using Fortran 90 code because of its number crunching power and the capability to directly access real fluid property subroutines in the Reference Fluid Thermodynamic and Transport Properties (REFPROP) Database developed by NIST. A Microsoft Excel front end user interface was implemented to provide convenient portability of PFSAT among a wide variety of potential users and its ability to utilize a user-friendly graphical user interface (GUI) developed in Visual Basic for Applications (VBA). The focus of PFSAT is on-orbit reaction control systems and orbital maneuvering systems, but it may be used to predict heat leak into ground-based transfer lines as well. PFSAT is expected to be used for rapid initial design of cryogenic propellant distribution lines and thermodynamic vent systems. Once validated, PFSAT will support concept trades for a variety of cryogenic fluid transfer systems on spacecraft, including planetary landers, transfer vehicles, and propellant depots, as well as surface-based transfer systems. The details of the development of PFSAT, its user interface, and the program structure will be presented.

  8. Plasma focusing in coaxial gun

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.; El-Khalafawy, T.

    1986-01-01

    A capacitor bank has been discharged between two coaxial electrodes of 6.6 cm outer diameter, 3.2 cm inner diameter and length of 31.5 cm. filled with hydrogen gas at pressure of 310 μHg. Results show that, the axial and radial plasma current reach a maximum value at a position adjacent to the gun muzzle, at which the plasma focus occurs. The measurement of the electron temperature and density and azimuthal electric field along the axis of the expansion chamber, gives a maximum value at z∼18 cm from the gun muzzle, while the axial plasma current and velocity has a minimum value at that position. These results indicate that a second point of a plasma focus has been formed at z∼18 cm from the gun muzzle, along the axis of the expansion chamber

  9. An rf modulated electron gun pulser for linacs

    International Nuclear Information System (INIS)

    Legg, R.; Hartline, R.

    1991-01-01

    Present linac injector designs often make use of sub-harmonic prebuncher cavities to properly bunch the electron beam before injection into a buncher and subsequent accelerating cavities. This paper proposes an rf modulated thermionic gun which would allow the sub-harmonic buncher to be eliminated from the injector. The performance parameters for the proposed gun are 120 kV operating voltage, macropulse duration-single pulse mode 2 nsec, multiple pulse mode 100 nsec, rf modularing frequency 500 MHz, charge per micropulse 0.4 nC, macropulse repetition frequency 10 Hz (max). The gun pulser uses a grid modulated planar triode to drive the gun cathode. The grid driver takes advantage of recently developed modular CATV rf drivers, high performance solid state pulser devices, and high-frequency fiber optic transmitters for telecommunications. Design details are presented with associated SPICE runs simulating operation of the gun

  10. Perancangan Sistem Kontrol PID Untuk Pengendali Sumbu Elevasi Gun Pada Turret-Gun Kaliber 20 Milimeter

    Directory of Open Access Journals (Sweden)

    Dimas Kunto Ariwibowo

    2017-01-01

    Full Text Available Pertahanan negara pada hakikatnya adalah segala upaya pertahanan yang bersifat semesta yang didasarkan pada kesadaran atas hak dan kewajiban warga negara serta keyakinan pada kekuatan sendiri dengan tujuan untuk menjaga dan melindungi kedaulatan negara, keutuhan wilayah NKRI dan keselamatan segenap bangsa. Salah satu alat pendukung pertahanan yaitu senjata laras panjang, Turret-Gun.  Adapun langkah-langkah yang dilakukan dalam merancang pengendali PID Turret-Gun kaliber 20mm ini diawali dengan studi literatur serta studi lapangan mengenai mekanisme dan parameter-parameter yang terdapat pada Turret-Gun pada sumbu elevasi. Setelah itu dilakukan perancangan transmisi dan sistem kontrol Turret-Gun untuk dievaluasi grafik responnya yang akan digunakan sebagai acuan untuk merancang pengendali PID yang sesuai. Selanjutnya pengendali PID yang telah dirancang lalu disimulasikan, sehingga menghasilkan grafik respon yang sesuai dengan kriteria yang dibutuhkan. Hasil yang telah didapatkan dari penelitian ini adalah konstanta PID yang direkomendasikan untuk , , dan secara berturut-turut adalah sebesar 23061.024, 37820.07 dan 3515.4 yang menghasilkan transient response dengan nilai overshoot sebesar 19.9 % , steady state error sebesar 0 % serta settling time sebesar 0.935 detik. Hasil analisa kestabilan untuk sistem kontrol dengan konstanta PID tersebut menunjukkan bahwa sistem kontrol telah stabil, baik menggunakan metode Root Locus maupun metode Routh-Hurwitz.

  11. rf traveling-wave electron gun for photoinjectors

    Directory of Open Access Journals (Sweden)

    Mattia Schaer

    2016-07-01

    Full Text Available The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  12. An advanced GAP/AN/TAGN propellant : part 2 : stability and storage life

    Energy Technology Data Exchange (ETDEWEB)

    Judge, M.D. [Bristol Aerospace, Winnipeg, MB (Canada); Badeen, C.M.; Jones, D.E.G. [Natural Resources Canada, Ottawa, ON (Canada). Canadian Explosives Research Laboratory

    2007-07-15

    An advanced solid propellant was characterized. The propellant was based on a glycidyl azide polymer (GAP) energetic binder with an ammonium nitrate (AN) oxidizer, and contained a significant percentage of triaminoguanidine nitrate (TAGN). Raw ingredient accelerating rate calorimetry (ARC) was performed to determine self-heating rates. Thermal stability and heat flow calorimetry tests were also conducted. Ballistic analyses were conducted to determine the propellant's burn rate. The propellant was designed to produce non-toxic and non-acidic exhaust products. Results of the tests indicated that the propellant is safe for prolonged storage. The study demonstrated that propellant samples can be heated to temperatures up to 175 degrees C for several hours without combustion response. A mass loss of 62 per cent was observed at temperatures between 160 and 230 degrees C. The samples ignited almost immediately after being placed in a pre-heated block at temperatures higher than 175 degrees C. The propellant's burn rate was approximately twice that of standard AN propellants. The propellant will be further evaluated as a candidate for the propulsion of tactical rockets and missiles. 17 refs., 4 tabs., 6 figs.

  13. Evaluation of Smart Gun Technologies preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, D.R.

    1996-01-01

    The Smart Gun Technology Project has a goal to eliminate the capability of an unauthorized user from firing a law enforcement officer`s firearm by implementing {open_quote}smart{close_quote} technologies. Smart technologies are those that can in some manner identify an officer. This report will identify, describe, and grade various technologies as compared to the requirements that were obtained from officers. This report does not make a final recommendation for a smart gun technology, nor does it give the complete design of a smart gun system.

  14. Gun utopias? Firearm access and ownership in Israel and Switzerland.

    Science.gov (United States)

    Rosenbaum, Janet E

    2012-02-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim mass-casualty events are mitigated and deterred with three policies: (a) permissive gun laws, (b) widespread gun ownership, (c) and encouragement of armed civilians who can intercept shooters. They cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal one to four times annually. ICVS analysis finds the United States has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers' firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40 per cent after the Israeli army's 2006 reforms. Compared with the United States, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership.

  15. Investigation on the wake evolution of contra-rotating propeller using RANS computation and SPIV measurement

    Directory of Open Access Journals (Sweden)

    Kwang-Jun Paik

    2015-05-01

    Full Text Available The wake characteristics of Contra-Rotating Propeller (CRP were investigated using numerical simulation and flow measurement. The numerical simulation was carried out with a commercial CFD code based on a Reynolds Averaged Navier-Stokes (RANS equations solver, and the flow measurement was performed with Stereoscopic Particle Image Velocimetry (SPIV system. The simulation results were validated through the comparison with the experiment results measured around the leading edge of rudder to investigate the effect of propeller operation under the conditions without propeller, with forward propeller alone, and with both forward and aft propellers. The evolution of CRP wake was analyzed through velocity and vorticity contours on three transverse planes and one longitudinal plane based on CFD results. The trajectories of propeller tip vortex core in the cases with and without aft propeller were also compared, and larger wake contraction with CRP was confirmed.

  16. Deflagration of thermite - ammonium nitrate based propellant mixture

    Science.gov (United States)

    Duraes, Luisa; Morgado, Joel; Portugal, Antonio; Campos, Jose

    2001-06-01

    Reaction between iron oxide (Fe2O3) and aluminum (Al) is the reference of the classic thermite compositions. The efficency of the reaction, for a given initial composition of Fe2O3 and Al, is evaluated by the final temperature and by the mass ratio of Al2O3 /AlO in products of combustion (in condensed phase). In order to increase pressure in products of thermite reaction, the original composition is mixed, with an original twin screw extruder, with a propellant binder composed of ammonium and sodium nitrates, initialy solved in formamide (CH3NO) and mixed with a polyurethane solution. The products of combustion and pyrolysis of this binder, reacting with thermite products, generates high pressure and high temperature conditions. These experimental conditions are also predicted using THOR code. The study presents DSC and TGA results of components and mixtures, and correlates them to the ignition phenomena and reaction properties. The regression rate of combustion and final attained temperature and pressure, in a closed confinement, as a function of composition of thermite components/propellant binder, are presented and discussed. They show the influence of gaseous combustion and pyrolysis products of binder in final reaction.

  17. Gun Dynamics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Gun Dynamics Laboratory is a research multi-task facility, which includes two firing bays, a high bay area and a second floor laboratory space. The high bay area...

  18. A high voltage test stand for electron gun qualification for LINACs

    International Nuclear Information System (INIS)

    Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam

    2011-01-01

    An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

  19. Project Minerva: A low cost manned Mars mission based on indigenous propellant production

    Science.gov (United States)

    Beder, David; Bryan, Richard; Bui, Tuyen; Caviezel, Kelly; Cinnamon, Mark; Daggert, Todd; Folkers, Mike; Fornia, Mark; Hanks, Natasha; Hamilton, Steve

    1992-01-01

    Project Minerva is a low-cost manned Mars mission designed to deliver a crew of four to the Martian surface using only two sets of two launches from the Kennedy Space Center. Key concepts which make this mission realizable are the use of near-term technologies and in-situ propellant production, following the scenario originally proposed by R. Zubrin. The first set of launches delivers two unmanned payloads into low Earth orbit (LEO): the first payload consists of an Earth Return Vehicle (ERV), a propellant production plant, and a set of robotic vehicles; the second payload consists of the trans-Mars injection (TMI) upper stage. In LEO, the two payloads are docked and the configuration is injected into a Mars transfer orbit. The landing on Mars is performed with the aid of multiple aerobraking maneuvers. On the Martian surface, the propellant production plant uses a Sabatier/electrolysis type process to combine nine tons of hydrogen with carbon dioxide from the Martian atmosphere to produce over a hundred tons of liquid oxygen and liquid methane, which are later used as the propellants for the rover expeditions and the manned return journey of the ERV. The systems necessary for the flights to and from Mars, as well as those needed for the stay on Mars, are discussed. These systems include the transfer vehicle design, life support, guidance and communications, rovers and telepresence, power generation, and propellant manufacturing. Also included are the orbital mechanics, the scientific goals, and the estimated mission costs.

  20. Engineering design of the PLX- α coaxial gun

    Science.gov (United States)

    Cruz, E.; Brockington, S.; Case, A.; Luna, M.; Witherspoon, F. D.; Thio, Y. C. Francis; PLX-α Team

    2017-10-01

    We describe the engineering and technical improvements, as well as provide a detailed overview of the design choices, of the latest PLX- α coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The evolution of the latest Alpha gun is presented with emphasis on its upgraded performance. Changes include a faster more robust gas valve, better-quality ceramic insulator material and enhancements to overall design layout. These changes result in a gun with increased repeatability, reduced potential failure modes, improved fault tolerance and better than expected efficiency. A custom 600- μF, 5-kV pfn and a set of six inline sparkgap switches operated in parallel are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  1. Clostridium geopurificans strain MJ1 sp. nov., a strictly anaerobic bacterium that grows via fermentation and reduces the cyclic nitramine explosive hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX).

    Science.gov (United States)

    Kwon, Man Jae; Wei, Na; Millerick, Kayleigh; Popovic, Jovan; Finneran, Kevin

    2014-06-01

    A fermentative, non-spore forming, motile, rod-shaped bacterium, designated strain MJ1(T), was isolated from an RDX contaminated aquifer at a live-fire training site in Northwest NJ, United States. On the basis of 16S rRNA gene sequencing and DNA base composition, strain MJ1(T) was assigned to the Firmicutes. The DNA G+C content was 42.8 mol%. Fermentative growth was supported by glucose and citrate in a defined basal medium. The bacterium is a strict anaerobe that grows between at pH 6.0 and pH 8.0 and 18 and 37 °C. The culture did not grow with hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) as the electron acceptor or mineralize RDX under these conditions. However, MJ1(T) transformed RDX into MNX, methylenedinitramine, formaldehyde, formate, ammonium, nitrous oxide, and nitrate. The nearest phylogenetic relative with a validly published name was Desulfotomaculum guttoideum (95 % similarity). However, MJ1(T) was also related to Clostridium celerecrescens DSM 5628 (95 %), Clostridium indolis DSM 755 (94 %), and Clostridium sphenoides DSM 632 (94 %). DNA:DNA hybridization with these strains was between 6.7 and 58.7 percent. The dominant cellular fatty acids (greater than 5 % of the total, which was 99.0 % recovery) were 16:0 fatty acid methyl ester (FAME) (32.12 %), 18:1cis 11 dimethyl acetal (DMA) (16.47 %), 16:1cis 9 DMA (10.28 %), 16:1cis 9 FAME (8.10 %), and 18:1cis 9 DMA (5.36 %). On the basis of morphological, physiological, and phylogenetic data, Clostridium geopurificans is proposed as a new species in genus Clostridium, with strain MJ1(T) as the type strain.

  2. Mass Shootings, Mental Illness, and Gun Control.

    Science.gov (United States)

    Philpott-Jones, Sean

    2018-03-01

    In the wake of the Stoneman Douglas School shooting, Republican and Democratic leaders-like the American electorate they represent-remain sharply divided in their responses to gun violence. They are united in their condemnation of these mass shootings, but they disagree about whether stricter or looser gun control laws are the answer. Those on the right side of the political aisle suggest that the issue is one of mental illness rather than gun control. Conversely, those who are more liberal or progressive in their political learnings are quick to condemn attempts to reframe the issue of mass shootings as a mental health problem. Both sides are wrong. Mass shootings are indeed partially a mental health problem, albeit one poorly addressed by our current laws and policies. But the solution to mass shootings also needs to consider strategies that may reduce gun violence in general. © 2018 The Hastings Center.

  3. 14 CFR 35.23 - Propeller control system.

    Science.gov (United States)

    2010-01-01

    ... propeller effect under the intended operating conditions. (4) The failure or corruption of data or signals... corruption of airplane-supplied data does not result in hazardous propeller effects. (e) The propeller... effect. (2) Failures or malfunctions directly affecting the propeller control system in a typical...

  4. Advanced technologies available for future solid propellant grains

    Energy Technology Data Exchange (ETDEWEB)

    Thepenier, J. [SNPE Propulsion, St Medard en Jalles (France); Fonblanc, G. [SNPE Propulsion, Vert le Petit (France). Centre de Recherche de Bouchet

    2001-06-01

    Significant advances have been made during the last decade in several fields of solid propulsion: the advances have enabled new savings in the motor development phase and in recurring costs, because they help limit the number of prototypes and tests. The purpose of the paper is to describe the improvements achieved by SNPE in solid grain technologies, making these technologies available for new developments in more efficient and reliable future SRMs: new energetic molecules, new solid propellants, new processes for grain manufacturing, quick response grain design tools associated with advanced models for grain performance predictions. Using its expertise in chemical synthesis, SNPE develops new molecules to fit new energetic material requirements. Tests based on new propellant formulations have produced good results in the propellant performance/safety behavior ratio. New processes have been developed simultaneously to reduce the manufacturing costs of the new propellants. In addition, the grain design has been optimized by using the latest generation of predictive theoretical tools supported by a large data bank of experimental parameters resulting from over 30 years' experience in solid propulsion: computer-aided method for the preliminary grain design; advanced models for SRM operating and performance predictions. All these technologies are available for industrial applications in future developments of solid propellant grains. (author)

  5. Handgun waiting periods reduce gun deaths.

    Science.gov (United States)

    Luca, Michael; Malhotra, Deepak; Poliquin, Christopher

    2017-11-14

    Handgun waiting periods are laws that impose a delay between the initiation of a purchase and final acquisition of a firearm. We show that waiting periods, which create a "cooling off" period among buyers, significantly reduce the incidence of gun violence. We estimate the impact of waiting periods on gun deaths, exploiting all changes to state-level policies in the Unites States since 1970. We find that waiting periods reduce gun homicides by roughly 17%. We provide further support for the causal impact of waiting periods on homicides by exploiting a natural experiment resulting from a federal law in 1994 that imposed a temporary waiting period on a subset of states. Copyright © 2017 the Author(s). Published by PNAS.

  6. Contoured-gap coaxial guns for imploding plasma liner experiments

    Science.gov (United States)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  7. Unusual Case of Suicide With a Modified Trap Gun.

    Science.gov (United States)

    Vadysinghe, Amal; Dassanayake, Prasanna; Wickramasinghe, Medhani

    2017-06-01

    Trap gun is an illegal, locally manufactured gun with a basic trip system used to hunt wild animals. The body of a 28-year-old man was found in the jungle in supine position with both legs apart. A trap gun was between the legs pointing toward the cranial side of the body. It had 2 free wires that were not connected together. There was no evidence of foul play.The body had a single-entry wound (2.5-cm diameter) in the anterior chest, with blackening, burning, and tattooing. Six metal particles and nylon clothing material were embedded into soft tissue. No exit wound was found. Toxicology analysis reported an alcohol level of 72 mg/dL. The cause of death was multiple shrapnel injury to the chest at close to intermediate range by a single discharge from a trap gun. Circumstance was concluded as suicide.Ballistic and firearm experts opined that an illegal, manually operated, battery-powered ignition device was used to ignite the gun powder. We report the first case of suicide by a modified trap gun in literature.

  8. Field reversal produced by a plasma gun

    International Nuclear Information System (INIS)

    Hartman, C.W.; Condit, W.; Granneman, E.H.A.; Prono, D.; Smith, A.C. Jr.; Taska, J.; Turner, W.C.

    1980-01-01

    Experimental results are presented of the production of Field-Reversed Plasma with a high energy coaxial plasma gun. The gun is magnetized with solenoids inside the center electrode and outside the outer electrode so that plasma emerging from the gun entrains the radial fringer field at the muzzle. The plasma flow extends field lines propagating a high electrical conductivity, the flux inside the center electrode should be preserved. However, for low flux, the trapped flux exceeds by 2 or more the initial flux, possibly because of helical deformation of the current channel extending from the center electrode

  9. Alpha Fuels Environmental Test Facility impact gun

    International Nuclear Information System (INIS)

    Anderson, C.G.

    1978-01-01

    The Alpha Fuels Environmental Test Facility (AFETF) impact gun is a unique tool for impact testing 238 PuO 2 -fueled heat sources of up to 178-mm dia at velocities to 300 m/s. An environmentally-sealed vacuum chamber at the muzzle of the gun allows preheating of the projectile to 1,000 0 C. Immediately prior to impact, the heat source projectile is completely sealed in a vacuum-tight catching container to prevent escape of its radioactive contents should rupture occur. The impact velocity delivered by this gas-powered gun can be regulated to within +-2%

  10. Thermomechanical Impact of Polyurethane Potting on Gun Launched Electronics

    Directory of Open Access Journals (Sweden)

    A. S. Haynes

    2013-01-01

    Full Text Available Electronics packages in precision guided munitions are used in guidance and control units, mission computers, and fuze-safe-and-arm devices. They are subjected to high g-loads during gun launch, pyrotechnic shocks during flight, and high g-loads upon impact with hard targets. To enhance survivability, many electronics packages are potted after assembly. The purpose of the potting is to provide additional structural support and shock damping. Researchers at the US Army recently completed a series of dynamic mechanical tests on a urethane-based potting material to assess its behavior in an electronics assembly during gun launch and under varying thermal launch conditions. This paper will discuss the thermomechanical properties of the potting material as well as simulation efforts to determine the suitability of this potting compound for gun launched electronics. Simulation results will compare stresses and displacements for a simplified electronics package with and without full potting. An evaluation of the advantages and consequences of potting electronics in munitions systems will also be discussed.

  11. Design study on an independently-tunable-cells thermionic RF gun

    International Nuclear Information System (INIS)

    Hama, H.; Tanaka, T.; Hinode, F.; Kawai, M.

    2006-01-01

    Characteristics of a thermionic RF gun have been studied by a 3-D simulation code developed using an FDTD (Finite Difference Time Domain) method as a Maxwell's equations solver. The gun is consists of two independent power feeding cavities, so that we call it independently-tunable-cells (ITC)'-RF gun. The first cell is the cathode cell and the second one is an accelerating cell. The ITC gun can be operated at various modes of different RF-power ratio and phase between two cavities. Simulation study shows a velocity-bunching like effect may be occurred in the gun, so that the short pulse beam from the thermionic RF gun is a better candidate to produce the coherent THz synchrotron radiation. Expected bunch length with a total charge of ∼20 pC (1% energy width from the top energy) is around 200 fs (fwhm). Even the beam energy extracted from the gun is varied by which the input powers are changed, almost same shape of the longitudinal phase space can be produced by tuning the phase. (author)

  12. The effects of electromagnetic space-charge fields in RF photocathode guns

    International Nuclear Information System (INIS)

    Park, C.S.; Hess, M.

    2010-01-01

    In high-brightness rf photocathode guns, the effects of space-charge are important for electron bunches with high bunch charge. In an effort to accurately simulate the effects of these space-charge fields without the presence of numerical grid dispersion, a Green's function based code called IRPSS (Indiana Rf Photocathode Source Simulator) was developed. In this paper, we show the results of numerical simulations of the Argonne Wakefield Accelerator photocathode gun using IRPSS, and compare them with the results of an electrostatic Green's function version of IRPSS.

  13. Youth, Guns, and the Juvenile Justice System. Research Report.

    Science.gov (United States)

    Butts, Jeffrey; Coggeshall, Mark; Gouvis, Caterina; Mears, Daniel; Travis, Jeremy; Waul, Michelle; White, Ruth

    This report documents trends in youth gun violence and the response within the justice system, noting the growing variety of data resources available to investigate the effect of new gun laws on youth, communities, and public safety. The first section reviews recent trends, examining the major wave of gun violence in the United States during the…

  14. Guns, Suicide, COPD and Sleep

    Directory of Open Access Journals (Sweden)

    Robbins RA

    2018-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Within the past year two tragic events, the shootings in Las Vegas and Florida have renewed the debate about guns. The politics and the money that fuels the political debate have sharply divided politicians. As tragic as these mass shootings are, deaths by suicide far outnumber the loss of live in these shootings. In 2014 suicide was the tenth most common cause of death with 42,826 lives lost (1. Half of the suicides were by firearm (21,386. The medical profession has traditionally been reluctant to speak about politically sensitive issues such as abortion, sexuality, and guns. However, beginning early in this millennium some medical societies such as the American Academy of Pediatrics, the US Preventative Services Task Force and even the Department of Veterans Affairs were suggesting physicians ask patients about gun behavior, but a few patients complained (2-5. There were some anecdotal reports of patients feeling “pressured” to answer …

  15. Hydrodynamics of Ship Propellers

    DEFF Research Database (Denmark)

    Breslin, John P.; Andersen, Poul

    This book deals with flows over propellers operating behind ships, and the hydrodynamic forces and moments which the propeller generates on the shaft and on the ship hull.The first part of the text is devoted to fundamentals of the flow about hydrofoil sections (with and without cavitation...... of an intermittently cavitating propeller in a wake and the pressures and forces it exerts on the shaft and on the ship hull is examined. A final chapter discusses the optimization of efficiency of compound propulsors. The authors have taken care to clearly describe physical concepts and mathematical steps. Appendices...

  16. Electron gun for the positron generator

    International Nuclear Information System (INIS)

    Fukuda, S.; Ogawa, Y.; Saito, Y.

    1986-01-01

    A triode electron gun has been installed on the Positron Generator at KEK, and brought into test operation. It involves a grid-cathode assembly currently used in a planner triode. The cathode has a diameter of 10 mm and is coated with Ba-Sr-Ca oxide. Because of the short grid-cathode distance (0.18 mm), the relatively low grid pulse voltages makes it possible to draw a high current. The assembly has a small vacuum flange which allows its easy replacement. Emission current from the oxide cathode is sensitive to residual gases, therefore, the vacuum system is carefully made and the pressure is kept in the range of 10 -9 Torr even when the accelerator is on. The grid pulser is a line type pulser using multi-stage avalanche transistors as a switch. The pulse width of 10 nsec has been used for the test to investigate the gun characteristics. The performance of the gun has been tested with this pulser and the emission current of 9.7 A was achieved at an injection voltage of 110 kV. The characteristics of the gun are described together with the beam trace

  17. Water guns affect abundance and behavior of bigheaded carp and native fish differently

    Science.gov (United States)

    Rivera, Jose; Glover, David C.; Kocovsky, Patrick; Garvey, James E.; Gaikowski, Mark; Jensen, Nathan R.; Adams, Ryan F.

    2017-01-01

    Water guns have shown the potential to repel nuisance aquatic organisms. This study examines the effects of exposure to a 1966.4 cm3 seismic water gun array (two guns) on the abundance and behavior of Bighead Carp Hypophthalmichthys nobilis, Silver Carp H. molitrix (collectively referred to as bigheaded carp) and native fishes (e.g., Smallmouth Buffalo Ictiobus bubalus). Water guns were deployed in a channel that connects the Illinois River to backwater quarry pits that contained a large transient population of bigheaded carp. To evaluate the effect of water guns, mobile side-looking split-beam hydroacoustic surveys were conducted before, during and between replicated water gun firing periods. Water guns did not affect abundance of bigheaded carp, but abundance of native fish detected during the firing treatment was 43 and 34% lower than the control and water guns off treatments, respectively. The proximity of bigheaded carp to the water gun array was similar between the water guns on and water guns off treatments. In contrast, the closest detected native fish were detected farther from the water guns during the water guns on treatment (mean ± SE, 32.38 ± 3.32 m) than during the water guns off treatment (15.04 ± 1.59 m). The water gun array had a greater impact on native fish species than on bigheaded carp. Caution should be taken to the extrapolation of these results to other fish species and to fish exposed to water guns in different environments (e.g., reduced shoreline interaction) or exposure to a larger array of water guns, or for use of water guns for purposes other than a barrier.

  18. Water guns affect abundance and behavior of bigheaded carp and native fish differently

    Science.gov (United States)

    Rivera, Jose; Glover, David C.; Kocovsky, Patrick; Garvey, James E.; Gaikowski, Mark; Jensen, Nathan R.; Adams, Ryan F.

    2018-01-01

    Water guns have shown the potential to repel nuisance aquatic organisms. This study examines the effects of exposure to a 1966.4 cm3 seismic water gun array (two guns) on the abundance and behavior of Bighead Carp Hypophthalmichthys nobilis, Silver Carp H. molitrix (collectively referred to as bigheaded carp) and native fishes (e.g., Smallmouth Buffalo Ictiobus bubalus). Water guns were deployed in a channel that connects the Illinois River to backwater quarry pits that contained a large transient population of bigheaded carp. To evaluate the effect of water guns, mobile side-looking split-beam hydroacoustic surveys were conducted before, during and between replicated water gun firing periods. Water guns did not affect abundance of bigheaded carp, but abundance of native fish detected during the firing treatment was 43 and 34% lower than the control and water guns off treatments, respectively. The proximity of bigheaded carp to the water gun array was similar between the water guns on and water guns off treatments. In contrast, the closest detected native fish were detected farther from the water guns during the water guns on treatment (mean ± SE, 32.38 ± 3.32 m) than during the water guns off treatment (15.04 ± 1.59 m). The water gun array had a greater impact on native fish species than on bigheaded carp. Caution should be taken to the extrapolation of these results to other fish species and to fish exposed to water guns in different environments (e.g., reduced shoreline interaction) or exposure to a larger array of water guns, or for use of water guns for purposes other than a barrier.

  19. Gun utopias? Firearm access and ownership in Israel and Switzerland

    OpenAIRE

    Rosenbaum, Janet

    2011-01-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim that mass-casualty events are mitigated and deterred with three policies: (1) permissive gun laws, (2) widespread gun ownership, (3) encouragement of armed civilians who can intercept shooters, and cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source m...

  20. Simulations of S-band RF gun with RF beam control

    Science.gov (United States)

    Barnyakov, A. M.; Levichev, A. E.; Maltseva, M. V.; Nikiforov, D. A.

    2017-08-01

    The RF gun with RF control is discussed. It is based on the RF triode and two kinds of the cavities. The first cavity is a coaxial cavity with cathode-grid assembly where beam bunches are formed, the second one is an accelerating cavity. The features of such a gun are the following: bunched and relativistic beams in the output of the injector, absence of the back bombarding electrons, low energy spread and short length of the bunches. The scheme of the injector is shown. The electromagnetic field simulation and longitudinal beam dynamics are presented. The possible using of the injector is discussed.