Sample records for rbs-channeling measurement system

  1. Low energy RBS-channeling measurement system with the use of a time-of-flight scattered ion detector

    Hasegawa, Masataka; Kobayashi, Naoto; Hayashi, Nobuyuki [Electrotechnical Lab., Tsukuba, Ibaraki (Japan)


    We have developed a low energy Rutherford backscattering spectrometry-ion channeling measurement system for the analysis of thin films and solid surfaces with the use of several tens keV hydrogen ions and a time-of-flight particle energy spectrometer. For the detection of the scattered ions new TOF spectrometer has been developed, which consists of two micro-channel-plate detectors. The pulsing of the primary ion beam is not necessary for this type of TOF measurement, and it is possible to observe continues scattered ion beams. The dimension of whole system is very compact compared to the conventional RBS-channeling measurement system with the use of MeV He ions. The energy resolution, {delta} E/E, for 25 keV H{sup +} was 4.1%, which corresponds to the depth resolution of 4.8 nm for silicon. The depth resolution of our system is better than that of conventional RBS system with MeV helium ions and solid state detectors. We have demonstrated the ion channeling measurement by this system with 25 keV hydrogen ions. The system can be available well to the analysis of thin films and solid surfaces with the use of the ion channeling effect. The observation of the reaction between Fe and hydrogen terminated silicon surface was also demonstrated. (J.P.N.)

  2. Investigation on the strain of SiGe/Si heteroepitaxial system during high temperature annealing by RBS/Channeling


    The influence of the high temperature processing on the strain stored in SiGe hetero epilayer was studied by means of RBS/Channeling. Channeling angularscan along the < 110 > axial direction in the (100) plane was used to characterize the tetragonal distortion in the SiGe strained layer. The strained crystal structure parameters were acquired by combining the determination of strain with the elasticity theory. It is shown that the strain stored in the SiGe epilayer has significantly change (relaxation factor from 0.023 to 0.84) after high temperature annealing. The potential strain relaxation mechanisms were discussed.

  3. Damage properties in ion-implanted YbVO4 crystals using RBS/Channeling study

    Jia, Chuan-Lei; Wei, Zhi-Ning


    YbVO4 crystals are implanted with 3.0 MeV Ni ions and 600 keV H ions with fluences of 2.0-10.0×1014 cm-2 and 6.0×1016 cm-2, respectively. In addition, post-implantation thermal annealing is performed at selected temperatures. The disorder induced by implantation and the effect of the annealing on the recovery of the crystal lattice are investigated by RBS/Channeling measurements with the help of simulation code RUMP.

  4. Lattice location of impurities in semiconductors: a RBS/channeling and proton-induced x-ray emission study

    Kringhoj, P. [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences


    Rutherford backscattering spectrometry (RBS)/channeling and proton-induced x-ray emission (PIXE) are two well established and characterised techniques. Over the last three decades RBS/channeling measurements has been performed to extract the substitutional fraction of impurities in both elemental and compound semiconductors. However, due to the limitation of RBS, only elements heavier than the host crystal can be examined (except for a few elements, where a nuclear reaction or a resonance can be used). In silicon this limitation is acceptable, due to the low mass of Si, but in the III-V compounds (e.g. InP), the technique is limited to a few elements of hardly no technological or fundamental interest. One can overcome this by combining RBS/channeling with PIXE, where PIXE is applied to detect elements with a mass lower than the host crystal. In the present work, the lattice location of Ge in InP has been studied and compared to the group-III impurity Ga, and the group-VI impurity Se which is known to be a donor. The (RBS)/channeling technique has been used to detect not only the substitutional fraction, but also the relative population of the two sublattices. The half-width is approximately equal to the characteristic angle, {psi}{sub 1}. The channeling data obtained indicate that all three dopants are located exclusively on substitutional sites and that Ga is occuping the In position, Se theP position and that Ge is distributed equally between both sublattices. 6 refs., 1 tab., 3 figs.

  5. Analysis of multilayer film using RBS/channeling, sputtering/RBS and SIMS

    Zhao Guo Qing; Zhou Zhu Ying; Jiang Lei; Song Ling Gen; Yang Yu


    RBS/Channeling, Sputtering/RBS and SIMS analysis have been performed on the MBE-grown Si/Ge sub x Si sub 1 sub - sub x multilayer. The thickness, atomic ratio and crystalline perfectness of the epitaxial layer are determined by 2 MeV sup 4 He sup + RBS/Channeling analysis. By sputter etching of the sample with low energy Ar sup + ions, the thickness of epitaxial layer is reduced. Then RBS analysis of 2 MeV sup 4 He sup + ions on the etched sample yields information about the deeper layers, the interface of the multilayer samples and the concerned phenomena induced by sputter etching. The periodical structure of Si/Ge sub x Si sub 1 sub - sub x multilayer samples is clearly identified by the SIMS analysis before and after sputter etching

  6. Structural analysis of erbium {delta}-doped InP by OMVPE with RBS-channeling

    Yuhara, Junji; Takeda, Hitoshi; Matsubara, Naoki; Tabuchi, Masao; Fujiwara, Yasufumi; Morita, Kenji; Takeda, Yoshikazu [Nagoya Univ. (Japan). School of Engineering


    We have determined the lattice location of Er in InP {delta}-doped by OMVPE with RBS-channeling. Er concentrations along the <001> and <011> directions are same as random yields, while a significant flux peaking effect is seen for the <111> direction. These data suggest that Er atoms occupy the site equivalent to the hexahedral site in InP lattice. (author)

  7. Performance of resistive-charge position sensitive detectors for RBS/Channeling applications

    Miranda, P.A., E-mail: [Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, 2696-953 Sacavém (Portugal); Wahl, U. [Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, 2696-953 Sacavém (Portugal); Catarino, N. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 2696-953 Sacavém (Portugal); Ribeiro da Silva, M. [Centro de Física Nuclear da Universidade de Lisboa, Avenida Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Alves, E. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 2696-953 Sacavém (Portugal)


    The performance of two types of 1×1 cm{sup 2} photodiode position sensitive detectors (PSDs) based on resistive charge division was evaluated for their use in Rutherford Backscattering/Channeling (RBS/C) experiments in blocking geometry. Their energy resolution was first determined for ∼5.5MeV alpha particles from a radioactive sources, and values of full width half maximum (FWHM) of 22 keV and 33 keV were achieved using a shaping time constant of τ=2.0μs. Additional tests were performed using backscattered {sup 4}He particles from the 2.0 MeV beam of a Van de Graaff accelerator. While the 22 keV FWHM detector failed after exposure to less than 5×10{sup 6} cm{sup −24}He particles, the other did not show any noticeable deterioration due to radiation damage for a fluence of 4×10{sup 8} cm{sup −2}. For this type of PSD position resolution (τ=0.5μs) standard deviations of ΔL=0.072mm at ∼5.5MeV and ΔL=0.247mm at 1.1 MeV were achieved. RBS/Channeling experiments using PSD were performed on several crystalline samples, showing that this setup seems suitable for lattice location studies, particularly for heavy ions implantation (D≳10{sup 15}at/cm{sup 2}) on light substrates like Si, SiC, and AlN.

  8. Multidirectional channeling analysis of epitaxial CdTe layers using an automatic RBS/channeling system

    Wielunski, L.S.; Kenny, M.J. [CSIRO, Lindfield, NSW (Australia). Applied Physics Div.


    Rutherford Backscattering Spectrometry (RBS) is an ion beam analysis technique used in many fields. The high depth and mass resolution of RBS make this technique very useful in semiconductor material analysis [1]. The use of ion channeling in combination with RBS creates a powerful technique which can provide information about crystal quality and structure in addition to mass and depth resolution [2]. The presence of crystal defects such as interstitial atoms, dislocations or dislocation loops can be detected and profiled [3,4]. Semiconductor materials such as CdTe, HgTe and Hg+xCd{sub 1-x}Te generate considerable interest due to applications as infrared detectors in many technological areas. The present paper demonstrates how automatic RBS and multidirectional channeling analysis can be used to evaluate crystal quality and near surface defects. 6 refs., 1 fig.

  9. A Comparison of GaN Epilayers with Multiple Buffer Layers and with a Single Buffer Layer Grown on Si(111) Studied by HRXRD and RBS/Channeling

    DING Zhi-Bo; WANG Kun; YAO Shu-De


    @@ Two hexagonal GaN epilayers (samples A and B) with multiple buffer layers and single buffer layer are grown on Si (111) by metal-organic vapour phase epitaxy (MOVPE).From the results of Rutherford backscattering (RBS)/channeling and high resolution x-ray diffraction (HRXRD),we obtain the lattice constant (a and c) of two GaN epilayers (aA = 0.3190 nm,cA = 0.5184 nm and aB = 0.3192 nm,cB = 0.5179 nm),the crystal quality of two GaN epilayers ( XminA = 4.87%,XminB=7.35% along axis) and the tetragonal distortion eT of the two samples along depth (sample A is nearly fully relaxed,sample B is not relaxed enough).

  10. Measurement System & Calibration report

    Kock, Carsten Weber; Vesth, Allan

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this report...

  11. Systemic risk measures

    Guerra, Solange Maria; Silva, Thiago Christiano; Tabak, Benjamin Miranda; de Souza Penaloza, Rodrigo Andrés; de Castro Miranda, Rodrigo César


    In this paper we present systemic risk measures based on contingent claims approach and banking sector multivariate density. We also apply network measures to analyze bank common risk exposure. The proposed measures aim to capture credit risk stress and its potential to become systemic. These indicators capture not only individual bank vulnerability, but also the stress dependency structure between them. Furthermore, these measures can be quite useful for identifying systemically important banks. The empirical results show that these indicators capture with considerable fidelity the moments of increasing systemic risk in the Brazilian banking sector in recent years.

  12. Health System Measurement Project

    U.S. Department of Health & Human Services — The Health System Measurement Project tracks government data on critical U.S. health system indicators. The website presents national trend data as well as detailed...

  13. Measuring Systemic Risk

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    We present a simple model of systemic risk and we show that each financial institution's contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...

  14. Precision volume measurement system.

    Fischer, Erin E.; Shugard, Andrew D.


    A new precision volume measurement system based on a Kansas City Plant (KCP) design was built to support the volume measurement needs of the Gas Transfer Systems (GTS) department at Sandia National Labs (SNL) in California. An engineering study was undertaken to verify or refute KCP's claims of 0.5% accuracy. The study assesses the accuracy and precision of the system. The system uses the ideal gas law and precise pressure measurements (of low-pressure helium) in a temperature and computer controlled environment to ratio a known volume to an unknown volume.

  15. Measuring Systemic Risk

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas


    We present an economic model of systemic risk in which undercapitalization of the financial sector as a whole is assumed to harm the real economy, leading to a systemic risk externality. Each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall...... of components of SES to predict emerging systemic risk during the financial crisis of 2007–2009....

  16. Electrochemical thermodynamic measurement system

    Reynier, Yvan; Yazami, Rachid; Fultz, Brent T.


    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  17. Measurement System Reliability Assessment

    Kłos Ryszard


    Full Text Available Decision-making in problem situations is based on up-to-date and reliable information. A great deal of information is subject to rapid changes, hence it may be outdated or manipulated and enforce erroneous decisions. It is crucial to have the possibility to assess the obtained information. In order to ensure its reliability it is best to obtain it with an own measurement process. In such a case, conducting assessment of measurement system reliability seems to be crucial. The article describes general approach to assessing reliability of measurement systems.

  18. Measuring Systemic Risk

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    We present a simple model of systemic risk and we show that each financial institution's contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution's leverage and with its expected loss in the tail of the system's loss distribution. Institutions internalize their externality if they are ‘taxed’ based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular...

  19. Measuring Systemic Risk

    Heje Pedersen, Lasse

    We present a simple model of systemic risk and we show that each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution’s leverage and with its expected loss in the tail of the system’s loss distribution. Institutions internalize their externality if they are “taxed” based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular......, (i) the outcome of stress tests performed by regulators; (ii) the decline in equity valuations of large financial firms in the crisis; and, (iii) the widening of their credit default swap spreads....

  20. Calorimetric measuring systems

    Ritchie, Andrew Ewen; Pedersen, John Kim; Blaabjerg, Frede


    the system cooling requirement. A common problem is that high-frequency phenomena like proximity effect, skin effect, hysteresis losses, and eddy current losses appear in the systems. These losses are very difficult to treat both theoretically and in practice. It is often difficult to measure the effect......Power Electronics remains an emerging technology. New materials, new devices, and new circuit topologies reduce the cost, weight, and volume for important applications [1]. Two important factors in power electronic circuits are the switching speed of the devices and the total power losses...... in the system. If the switching speed can be increased, improvements may be possible (e.g., current ripple in an electrical machine or physical size of passive components may be reduced). On the other hand, increased switching speed may cause additional losses in a power electronic system and increase...

  1. Enterprise performance measurement systems

    Milija Bogavac


    Full Text Available Performance measurement systems are an extremely important part of the control and management actions, because in this way a company can determine its business potential, its market power, potential and current level of business efficiency. The significance of measurement consists in influencing the relationship between the results of reproduction (total volume of production, value of production, total revenue and profit and investments to achieve these results (factors of production spending and hiring capital in order to achieve the highest possible quality of the economy. (The relationship between the results of reproduction and investment to achieve them quantitatively determines economic success as the quality of the economy. Measuring performance allows the identification of the economic resources the company has, so looking at the key factors that affect its performance can help to determine the appropriate course of action.

  2. Wireless Acoustic Measurement System

    Anderson, Paul D.; Dorland, Wade D.; Jolly, Ronald L.


    A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server

  3. Thermal microstructure measurement system

    Carver, Michael J. (Inventor)


    A thermal microstructure measurement system (TMMS) operates autonomously h its own internal power supply and telemeters data to a platform. A thermal array is mounted on a cross-braced frame designed to orient itself normal to existing currents with fixed sensor positioning bars protruding from the cross bars. A plurality of matched thermistors, conductivity probes and inclinometers are mounted on the frame. A compass and pressure transducer are contained in an electronics package suspended below the array. The array is deployed on a taut mooring below a subsurface float. Data are digitized, transmitted via cable to a surface buoy and then telemetered to the platform where the data is processed via a computer, recorded and/or displayed. The platform computer also sends commands to the array via telemetry.

  4. Systems Measures of Water Distribution System Resilience

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Murray, Regan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walker, La Tonya Nicole [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)


    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  5. Measurement System and Calibration report

    Kock, Carsten Weber; Vesth, Allan

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this report...

  6. Measurement System and Calibration report

    Gómez Arranz, Paula; Villanueva, Héctor

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this repor...

  7. Measurement Systems Advisory Group


    noted with the aluminum wire used in the lacing. For these reasons the tests were concluded and deemed unsatisfactory. The second system tested was an...vehicle for "bringing many particulate pollutants into contact with the tape or magnetic heads, e.g., from deodorant spray powders, face powder and

  8. Measuring name system health

    Casalicchio, Emiliano; Caselli, M.; Coletta, Alessio; Di Blasi, Salvatore; Fovino, Igor Nai; Butts, Jonathan; Shenoi, Sujeet


    Modern critical infrastructure assets are exposed to security threats arising from their use of IP networks and the Domain Name System (DNS). This paper focuses on the health of DNS. Indeed, due to the increased reliance on the Internet, the degradation of DNS could have significant consequences for

  9. Measuring name system health

    Casalicchio, Emiliano; Caselli, Marco; Coletta, Alessio; Di Blasi, Salvatore; Fovino, Igor Nai; Butts, Jonathan; Shenoi, Sujeet


    Modern critical infrastructure assets are exposed to security threats arising from their use of IP networks and the Domain Name System (DNS). This paper focuses on the health of DNS. Indeed, due to the increased reliance on the Internet, the degradation of DNS could have significant consequences for

  10. Eddy Correlation Flux Measurement System

    Oak Ridge National Laboratory — The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat,...

  11. Carbon Dioxide Flux Measurement Systems

    Oak Ridge National Laboratory — The Southern Great Plains (SGP) carbon dioxide flux (CO2 flux) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), and sensible heat. The...

  12. Endovascular blood flow measurement system

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu


    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  13. Measuring Complexity of SAP Systems

    Ilja Holub


    Full Text Available The paper discusses the reasons of complexity rise in ERP system SAP R/3. It proposes a method for measuring complexity of SAP. Based on this method, the computer program in ABAP for measuring complexity of particular SAP implementation is proposed as a tool for keeping ERP complexity under control. The main principle of the measurement method is counting the number of items or relations in the system. The proposed computer program is based on counting of records in organization tables in SAP.

  14. Airborne Atmospheric Aerosol Measurement System

    Ahn, K.; Park, Y.; Eun, H.; Lee, H.


    It is important to understand the atmospheric aerosols compositions and size distributions since they greatly affect the environment and human health. Particles in the convection layer have been a great concern in global climate changes. To understand these characteristics satellite, aircraft, and radio sonde measurement methods have usually been used. An aircraft aerosol sampling using a filter and/or impactor was the method commonly used (Jay, 2003). However, the flight speed particle sampling had some technical limitations (Hermann, 2001). Moreover, the flight legal limit, altitude, prohibited airspace, flight time, and cost was another demerit. To overcome some of these restrictions, Tethered Balloon Package System (T.B.P.S.) and Recoverable Sonde System(R.S.S.) were developed with a very light optical particle counter (OPC), impactor, and condensation particle counter (CPC). Not only does it collect and measure atmospheric aerosols depending on altitudes, but it also monitors the atmospheric conditions, temperature, humidity, wind velocity, pressure, GPS data, during the measurement (Eun, 2013). In this research, atmospheric aerosol measurement using T.B.P.S. in Ansan area is performed and the measurement results will be presented. The system can also be mounted to an unmanned aerial vehicle (UAV) and create an aerial particle concentration map. Finally, we will present measurement data using Tethered Balloon Package System (T.B.P.S.) and R.S.S (Recoverable Sonde System).

  15. HLS bunch current measurement system


    Bunch current is an important parameter for studying the injection fill-pattern in the storage ring and the instability threshold of the bunch, and the bunch current monitor also is an indispensable tool for the top-up injection. A bunch current measurement (BCM) system has been developed to meet the needs of the upgrade project of Hefei Light Source (HLS). This paper presents the layout of the BCM system. The system based on a high-speed digital oscilloscope can be used to measure the bunch current and synchronous phase shift. To obtain the absolute value of bunch-by-bunch current, the calibration coefficient is measured and analyzed. Error analysis shows that the RMS of bunch current is less than 0.01 mA when bunch current is about 5 mA, which can meet project requirement.

  16. Measurement of mobile antenna systems

    Arai, Hiroyuki


    If you're involved with the design, installation or maintenance of mobile antenna systems, this thoroughly revised and updated edition of a classic Artech book offers you the most current and comprehensive coverage of all the mandatory measurement techniques you need for your work in the field. This Second Edition presents critical new material in key areas, including radiation efficiency measurement, mobile phone usage position, and MIMO (multiple-input/multiple-output) antennas.This unique resource provides in-depth examinations of all relevant mobile antenna measurement theories, along with

  17. Direction-dependent RBS channelling studies in ion implanted LiNbO3

    Wendler, E.; Becker, G.; Rensberg, J.; Schmidt, E.; Wolf, S.; Wesch, W.


    Damage formation in ion implanted LiNbO3 was studied by Rutherford backscattering spectrometry (RBS) along various directions of the LiNbO3 crystal. From the results obtained it can be unambiguously concluded that Nb atoms being displaced during ion implantation preferably occupy the free octahedron sites of the LiNbO3 lattice structure and most likely also form NbLi antisite defects.

  18. Direction-dependent RBS channelling studies in ion implanted LiNbO{sub 3}

    Wendler, E., E-mail:; Becker, G.; Rensberg, J.; Schmidt, E.; Wolf, S.; Wesch, W.


    Damage formation in ion implanted LiNbO{sub 3} was studied by Rutherford backscattering spectrometry (RBS) along various directions of the LiNbO{sub 3} crystal. From the results obtained it can be unambiguously concluded that Nb atoms being displaced during ion implantation preferably occupy the free octahedron sites of the LiNbO{sub 3} lattice structure and most likely also form Nb{sub Li} antisite defects.

  19. Tetragonal Distortion of InN Thin Films by RBS/Channeling

    DING Zhi-Bo; WU Wei; WANG Kun; FA Tao; YAO Shu-De


    Rutherford backscattering and channeling spectrometry (RBS/C) are used to identify the crystalline quality (Xmin = 4.87%) of an InN thin film as a function of depth,and make a non-destructive quantitative analysis of the structure,in order to analyze the tetragonal distortion of the InN thin film at the depth determined.

  20. Understanding Process Performance Measurement Systems

    Ljubica MilanoviÊ Glavan


    Full Text Available The purpose of this paper is to analyze the current state of Process Performance Measurement Systems (PPMS by means of a systematic review of literature. The PPMS literature is reviewed using a systematic approach. Based on an extensive literature review only twelve articles that contain the term PPMS in the title were found. The literature analysis showed that PPMS is a relatively new topic in the area of performance measurement. In order to understand PPMS, it was crucial to explain the concepts of business process management, business performance measurement and Performance Measurement System (PMS which are well known and used in the literature and practice. PPMS is a special type of PMS that should be used in process-oriented organizations. Limitations of this research lie in the fact that all the conclusions were derived only from the literature, not empirical research. The results presented in the paper continue towards providing an updated overview of the current state of performance measurement, especially PPMS in order to identify the existing research gaps on which ongoing and future research efforts regarding this topic can be focused.

  1. DC Magnetics Measurement System Design

    Mastny, Timothy


    This report will detail the updates to the magnetics measurement system design and testing procedures that are required for performing static (DC) magnetics testing of future flight hardware. An older magnetics testing system had to be integrated with new procedures and hardware to meet the demands of future testing programs and accommodate an upcoming magnetics tests. The next test will be for the Geostationary Operational Environmental Satellite R-Series (GOES-R), which will verify that the SAFT Battery component meets its specifications for magnetic cleanliness. The satellite is scheduled to launch in 2015 with magnetics testing to be completed on the battery in November 2012.

  2. Wireless sap flow measurement system

    Kuo, C.; Davis, T. W.; Tseng, C.; Cheng, C.; Liang, X.; Yu, P.


    This study exhibits a measurement system for wireless sensor networks to measure sap flow in multiple locations simultaneously. Transpiration is a major component of the land-surface system because it is indicative of the water movement between the soil and the air. Sap flow can be used to approximate transpiration. In forests, transpiration cannot be represented by the sap flow from a single tree. Multi-location sap flow measurements are required to show the heterogeneity caused by different trees or soil conditions. Traditional multi-location measurements require manpower and capital for data collection and instrument maintenance. Fortunately, multi-location measurements can be achieved by using the new technology of wireless sensor networks. With multi-hop communication protocol, data can be forwarded to the base station via multiple sensor nodes. This communication protocol can provide reliable data collection with the least power consumption. This study encountered two major problems. The first problem was signal amplification. The Crossbow IRIS mote was selected as the sensor node that receives the temperature data of the sap flow probe (thermocouple) through a MDA300 data acquisition board. However, the wireless sensor node could not directly receive any data from the thermocouples since the least significant bit value of the MDA300, 0.6 mV, is much higher than the voltage signal generated. Thus, the signal from the thermocouple must be amplified to exceed this threshold. The second problem is power management. A specific heat differential is required for the thermal dissipation method of measuring sap flow. Thus, an adjustable DC power supply is necessary for calibrating the heater's temperature settings. A circuit was designed to combine the signal amplifier and power regulator. The regulator has been designed to also provide power to the IRIS mote to extend battery life. This design enables wireless sap flow measurements in the forest. With the

  3. Stochastic measurements and systems implications

    Collins, J. L.; Greene, R. R.


    The U.S. Navy is defining the baseline performance of the current SSN ASW suite in the Arctic operating environment. This suite includes the AN/BQQ-5 sonar suit (including the Towed Array, the sphere and other sensor and processor sub-systems), communications subsystems and weapon systems (Mk 48 and ADCAP). An effective acoustic measurement program in the Arctic must support the evaluation of how well the different subsystems are able to carry out their assigned functions. Unique aspects of the operating environment in the Arctic include unusual noise properties, unusual transmission effects and an unusual sea surface. This report addresses those acoustic transmission effects which affect system performance due to fluctuations or spreads in the acoustic field space, angle time and frequency.

  4. Directional spectral emissivity measurement system

    Halyo, Nesim (Inventor); Pandey, Dhirendra K. (Inventor)


    Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

  5. Indicators System for Poverty Measurement

    Constantin Mitrut


    Full Text Available Poverty represents a life aspect which is focusing the attention of both the macroeconomic analysis and the international comparisons. In order to measure the level being recorded by this phenomenon, there is a system of indicators which are used in order to underline, in a correlated manner, a number of aspects which are characterizing, quality and quantity wise, the evolution of the poverty in a specific country or, to a larger extent, through comparative surveys, at international level. Despite the fact that they are not the only instrument being used within the process of comparison of the stages of social and economic development at the international level, however the poverty indicators are providing a clear significance to the worked out surveys. In fact, the very purpose of the economic activity consists of increasing welfare and, as much as possible, at least reducing, if not eradicating, the poverty. The present work is broadly presenting the methodology as well as, both theoretical and practical, the way of computing the poverty, making a synthesis of the specific used indicators.

  6. Measurement System and Calibration report

    Vesth, Allan; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...

  7. Mobile measurement system for wind turbines

    Kildemoes Moeller, T.


    The aim of this project `Udviklingsafproevning af smaa moellevinger` has been to develop a mobile measurement system for wind turbines. The following report describes the measurement system. The project has been financed by the Danish Ministry of Energy. (au)

  8. The Applications of Measurement System for Crankshaft

    DAI Shangping; GAO Li; GAO Kai


    This paper will introduce two types of multi-parameter co-measuring system and their application in the production. The first is crankshaft bent deformation measuring machine system. The second is the crankshaft pneumatic-electric measuring system. They have been used in final inspection procedure of automation line for crankshaft of automobie engine with good results, the structure principle and soft clash technological process of the measurement system are presented.

  9. Measures of Autonomic Nervous System


    Resiliency Model (TRM)* X* X* Trauma and Tension Releasing Exercises (TRE) Yoga (Asana) Postures X X Breathing Practices...MBSR) Yoga Nidra (iRest) X X *Study currently in progress utilizing these measures 7...measuring oxygen saturation of blood. The Doppler radar cardiopulmonary remote sensing unit and the wearable reflectance pulse oximeter have the benefit

  10. Introduction to control system performance measurements

    Garner, K C


    Introduction to Control System Performance Measurements presents the methods of dynamic measurements, specifically as they apply to control system and component testing. This book provides an introduction to the concepts of statistical measurement methods.Organized into nine chapters, this book begins with an overview of the applications of automatic control systems that pervade almost every area of activity ranging from servomechanisms to electrical power distribution networks. This text then discusses the common measurement transducer functions. Other chapters consider the basic wave

  11. Low Temperature Emissivity Measurement System

    Jignesh A. Patel


    Full Text Available The emissivity of a material is the relative ability of its surface to emit energy by radiation. It is the ratio of energy radiated by a particular material to energy radiated by a black body at the same temperature. Knowledge about the low temperature emissivity of materials and coatings can be essential to the design of fusion cryoplants and in the thermal modeling for space satellite missions. The emittance of materials at cryogenics temperatures often cannot be predicted from room temperature data, but for computing radiative loads and infrared backgrounds this cryogenic data is often required. Measurement of the cryogenic emissivity of a highly reflective surface is a significant challenge: little thermal power is radiated from the sample, and the background radiation. However some researchers have measured emissivity at various low temperature ranges. Present work reports, the various emissivity measurement setup and their considerations.

  12. Breathing detection with a portable impedance measurement system: first measurements.

    Cordes, Axel; Foussier, Jerome; Leonhardt, Steffen


    For monitoring the health status of individuals, detection of breathing and heart activity is important. From an electrical point of view, it is known that breathing and heart activity change the electrical impedance distribution in the human body over the time due to ventilation (high impedance) and blood shifts (low impedance). Thus, it is possible to detect both important vital parameters by measuring the impedance of the thorax or the region around lung and heart. For some measurement scenarios it is also essential to detect these parameters contactless. For instance, monitoring bus drivers health could help to limit accidents, but directly connected systems limit the drivers free moving space. One measurement technology for measuring the impedance changes in the chest without cables is the magnetic impedance tomography (MIT). This article describes a portable measurement system we developed for this scenario that allows to measure breathing contactless. Furthermore, first measurements with five volunteers were performed and analyzed.

  13. High Temperature Superconducting Maglev Measurement System

    Wang, Jia-Su; Wang, Su-Yu


    Three high temperature superconducting (HTS) Maglev measurement systems were successfully developed in the Applied Superconductivity Laboratory (ASCLab) of Southwest Jiaotong University, P. R. China. These systems include liquid nitrogen vessel, Permanent Magnet Guideway (PMG), data collection and processing, mechanical drive and Autocontrol features. This chapter described the three different measuring systems along with their theory of operations and workflow. The SCML-01 HTS Maglev measure...

  14. 600-GHz Electronically Tunable Vector Measurement System

    Dengler, Robert; Maiwald, Frank; Siegel, Peter


    A compact, high-dynamic-range, electronically tunable vector measurement system that operates in the frequency range from approximately 560 to approximately 635 GHz has been developed as a prototype of vector measurement systems that would be suitable for use in nearly-real-time active submillimeter-wave imaging. As used here, 'vector measurement system" signifies an instrumentation system that applies a radio-frequency (RF) excitation to an object of interest and measures the resulting amplitude and phase response, relative to either the applied excitatory signal or another reference signal related in a known way to applied excitatory signal.

  15. SQUID-based measuring systems

    M P Janawadkar; R Baskaran; R Nagendran; K Gireesan; N Harishkumar; Rita Saha; L S Vaidhyanathan; J Jayapandian; Y Hariharan; T S Radhakrishnan


    A program has been developed and initiated at the Indira Gandhi Centre for Atomic Research (IGCAR) for the utilization of SQUID sensors in various application areas. DC SQUID sensors based on Nb–AlO–Nb Josephson junctions have been designed and developed inhouse along with associated flux-locked loop (FLL) electronics. A compact low field SQUID magnetometer insertible in a liquid helium storage dewar has also been developed inhouse and is in use. Efforts to build a high field SQUID magnetometer, SQUID-DAC system, are in progress. A planar gradiometric DC SQUID sensor for non-destructive evaluation (NDE) application to be used in relatively unshielded environment has been designed and developed. An easily portable NDE cryostat with a small lift-off distance, to be used in external locations has been designed and tested. The magnetic field produced by a given two-dimensional current density distribution is inverted using the Fourier transform technique.

  16. Measurement of SIFT operating system overhead

    Palumbo, D. L.; Butler, R. W.


    The overhead of the software implemented fault tolerance (SIFT) operating system was measured. Several versions of the operating system evolved. Each version represents different strategies employed to improve the measured performance. Three of these versions are analyzed. The internal data structures of the operating systems are discussed. The overhead of the SIFT operating system was found to be of two types: vote overhead and executive task overhead. Both types of overhead were found to be significant in all versions of the system. Improvements substantially reduced this overhead; even with these improvements, the operating system consumed well over 50% of the available processing time.

  17. Electro-optical imaging system performance measurement

    Bijl, P.; Toet, A.; Valeton, J.M.


    The minimum resolvable temperature difference (MRTD), the minimum resolvable contrast (MRC), and the triangle orientation discrimination (TOD) are end-to-end EO system performance measures; that is, laboratory measures that characterize EO system performance with a human observer in the loop. Such s

  18. [Wireless ECG measurement system with capacitive coupling].

    Aleksandrowicz, Adrian; Walter, Marian; Leonhardt, Steffen


    This paper describes a measurement system that captures an electrocardiogram (ECG) using capacitively coupled electrodes. The measurement system was integrated into an off-the-shelf office chair (so-called "Aachen SmartChair"). Whereas for classical ECG measurement adhesive is used to attach conductively coupled electrodes to bare skin, the system presented allows ECG measurement through clothing without direct skin contact. Furthermore, a ZigBee communication module was integrated to allow wireless transmission of ECG data to a PC or an ICU patient monitor. For system validation, classical ECG using conductive electrodes was obtained simultaneously. First measurement results, including variations of cloth thickness and material, are presented and some of the system-specific problems of this approach are discussed.

  19. Microminiature Inertial Measurement System and Its Applications

    毛刚; 顾启泰


    The microminiature inertial measurement system, a new style of inertial measurement system, hasmany advantages compared with traditional systems, such as small size, Iow mass, low cost, low powerconsumption, high bearing capacity, and long life. Undoubtedly, it will have wide applications in military andcommercial fields. However, current micro inertial sensors do not have sufficient accuracy, so, its applicationsare limited to some extent. This paper describes a microminiature inertial measurement system and its design,operating theory and error control techniques. In addition, its performance and applications are evaluated.``

  20. Ocular microtremor measurement system: design and performance.

    Sheahan, N F; Coakley, D; Hegarty, F; Bolger, C; Malone, J


    The frequency of ocular microtremor (OMT) is related to the functional status of the brain stem, and thus OMT may be useful in the diagnosis and management of brain stem disorders. The paper discusses the design of an OMT measurement system and reports quantitative specifications for three portable systems. All systems use a piezo-electric element as the transducer, which measures the displacement of the sclera during eye rotations. The systems differ in the manner in which the signal is recorded. All systems can detect eye movements corresponding to displacements of the sclera ranging from 12 to over 3000 nm. The frequency responses of all systems are flat (< 2 dB deviation from peak response) between 20 and 150 Hz. The phase response shows deviations (< pi) at the extremes of this range, but qualitative comparison of input and measured signals demonstrates that phase distortion is not excessive. Thus all systems are acceptable for clinical studies involving OMT.

  1. Turbine gas temperature measurement and control system

    Webb, W. L.


    A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

  2. Measuring Fiscal Capacity of School Systems.

    Green, Harry A.

    Ways of measuring the fiscal capacity of school systems are examined in this paper, which presents a representative tax system model. Fiscal capacity is influenced by factors other than tax base size; the "ideal" model should address adjustments for variations in cost across communities and school systems. The first section examines the…

  3. The NIST Primary Radon-222 Measurement System

    Collé, R.; Hutchinson, J. M. R.; Unterweger, M. P.


    Within the United States, the national standard for radon measurements is embodied in a primary radon measurement system that has been maintained for over 50 years to accurately measure radon (222Rn) against international and national radium (226Ra) standards. In turn, all of the radon measurements made at the National Institute of Standards and Technology (NIST) and the radon transfer calibration standards and calibration services provided by NIST are directly related to this national radon ...

  4. System Entropy Measurement of Stochastic Partial Differential Systems

    Bor-Sen Chen


    Full Text Available System entropy describes the dispersal of a system’s energy and is an indication of the disorder of a physical system. Several system entropy measurement methods have been developed for dynamic systems. However, most real physical systems are always modeled using stochastic partial differential dynamic equations in the spatio-temporal domain. No efficient method currently exists that can calculate the system entropy of stochastic partial differential systems (SPDSs in consideration of the effects of intrinsic random fluctuation and compartment diffusion. In this study, a novel indirect measurement method is proposed for calculating of system entropy of SPDSs using a Hamilton–Jacobi integral inequality (HJII-constrained optimization method. In other words, we solve a nonlinear HJII-constrained optimization problem for measuring the system entropy of nonlinear stochastic partial differential systems (NSPDSs. To simplify the system entropy measurement of NSPDSs, the global linearization technique and finite difference scheme were employed to approximate the nonlinear stochastic spatial state space system. This allows the nonlinear HJII-constrained optimization problem for the system entropy measurement to be transformed to an equivalent linear matrix inequalities (LMIs-constrained optimization problem, which can be easily solved using the MATLAB LMI-toolbox (MATLAB R2014a, version 8.3. Finally, several examples are presented to illustrate the system entropy measurement of SPDSs.

  5. Analysis of measurement system as the mechatronics system

    Giniotis, V.; Grattan, K. T. V.; Rybokas, M.; Bručas, D.


    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  6. Analysis of measurement system as the mechatronics system

    Giniotis, V [Institute of Geodesy, Vilnius Gediminas Technical University, Vilnius, Lithuania, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Grattan, K T V [School of Engineering and Mathematical Sciences Electrical, Electronic and Information Eng, City University, Northampton Square, London EC1V 0HB (United Kingdom); Rybokas, M [Department of Information Technologies, Vilnius Gediminas Technical University, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Brucas, D, E-mail: gi@ap.vtu.l, E-mail:, E-mail: MRybokas@gama.l, E-mail: domka@ktv.l, E-mail: vg@ai.vgtu.l [Department of Geodesy and Cadastre, Vilnius Gediminas Technical University, Vilnius, Lithuania Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania)


    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  7. Dynamic Properties of Impulse Measuring Systems

    Pedersen, A.; Lausen, P.


    After some basic considerations the dynamic properties of the measuring system are subjected to a general examination based on a number of responses, characteristic of the system. It is demonstrated that an impulse circuit has an internal impedance different from zero, for which reason the intera......After some basic considerations the dynamic properties of the measuring system are subjected to a general examination based on a number of responses, characteristic of the system. It is demonstrated that an impulse circuit has an internal impedance different from zero, for which reason...

  8. Preparation Measurements and Assessment of Roof Systems

    Baláž Richard


    Full Text Available The Institute of Architectural Engineering at the Civil Engineering Faculty TU of Kosice, in its ongoing research, aims to monitor the physical properties of building envelope structures with emphasis placed on hydrothermal problems, at present. The research focuses on the assembly of equipment in climate chambers with their respective sample envelopes and fenestration systems, which are involved in a measuring experiment. The prime aim is to design a logical and transparent system for gathering, evaluating and storing hydrothermal related data. This contribution further illustrates the embedding system of measurement points in installed samples and the system of monitoring their physical properties over an annual period.

  9. Preparation Measurements and Assessment of Roof Systems

    Baláž, Richard; Bagoňa, Miloslav


    The Institute of Architectural Engineering at the Civil Engineering Faculty TU of Kosice, in its ongoing research, aims to monitor the physical properties of building envelope structures with emphasis placed on hydrothermal problems, at present. The research focuses on the assembly of equipment in climate chambers with their respective sample envelopes and fenestration systems, which are involved in a measuring experiment. The prime aim is to design a logical and transparent system for gathering, evaluating and storing hydrothermal related data. This contribution further illustrates the embedding system of measurement points in installed samples and the system of monitoring their physical properties over an annual period.

  10. Three-component laser anemometer measurement systems

    Goldman, Louis J.


    A brief overview of the different laser anemometer (LA) optical designs available is presented. Then, the LA techniques that can be used to design a three-component measurement system for annular geometries are described. Some of the facility design considerations unique to these LA systems are also addressed. Following this, the facilities and the LA systems that were used to successfully measure the three components of velocity in the blading of annular-flow machines are reviewed. Finally, possible LA system enhancements and future research directions are presented.

  11. SIMS: The SLAC Industrial Measurement System

    Bell, B.; /SLAC


    The development of electronic sensors and of small powerful computers, and their integration together have led to the development of what has come to be known as Industrial Measurement Technology (IMT). Industrial Measurement Systems feature one or more electronic sensors and a computer with powerful software. The software has three essential components: data collection, data reduction and data analysis. In the field of industrial surveying, the IMT system is the automated theodolite system, but other systems such as the laser tracker are on the horizon.

  12. Measurement system as a subsystem of the quality management system

    Ľubica Floreková


    Full Text Available Each measurement system and a control principle must be based on certain facts about the system behaviour (what, operation (how and structure (why. Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirements defines the measurement, analysis and improvement for each organization in order to present the products conformity, the quality management system conformity guarantee and for the continuously permanent improvement of effectivity, efficiency and economy of quality management system.

  13. Coordination of Passive Systems under Quantized Measurements

    De Persis, Claudio; Jayawardhana, Bayu


    In this paper we investigate a passivity approach to collective coordination and synchronization problems in the presence of quantized measurements and show that coordination tasks can be achieved in a practical sense for a large class of passive systems.

  14. Measurement of photometric characteristics of daylighting systems

    Aydinli, S.; Kaase, H. [Technical Univ., Berlin (Germany); Kischkoweit-Lopin, M. [Institut fuer Licht- und Bautechnik an der FH Koln, Cologne (Germany); Scartezzini, J. L.; Michel, L. [Ecole Poytechnuque Federale de Lausanne (Switzerland); Wienold, J.; Apian-Bennewitz, P. [Frauenhofer Institute for Solar Energy Systems, Freiburg (Germany)


    The photometric properties of daylighting systems determine the quality of the daylighting in the interior of a building, as well as the possible energy savings by the daylight responsive artificial lighting control systems. Photometric characteristics of daylighting systems and the principles of their measurements in laboratory facilities are described. Characteristics that depend on light incidence and observation of radiation can be measured using integrating sphere photometers or goniophotometers. Luminous transmittance measurements are usually carried out using integrating sphere photometers (cheaper and less time -consuming than measurements with a goniometer). Although the principles involved in the measurement are well understood, results frequently show certain deviations. The various errors that might be responsible for these deviations, whether attributable to the method, or the instrument, or the sample, are also discussed. 10 refs., 8 figs.

  15. Navigational and Environmental Measurement System (NEMS)

    Clem, T. D.


    The NEMS concept and design were initiated from the need to measure and record positional and environmental information during aircraft flights of developmental science research instrumentation. The unit was designed as a stand-alone system which could serve the needs of instruments whose developmental nature did not justify the cost and complexity of including these measurements within the instrument data system. Initially, the system was comprised of a Loran-C receiver and a portable IBM compatible computer recording position and time. Later, the system was interfaced with the Wallops aircraft inertial navigation system (INS), and various other sensors were supplied and shared by the Goddard science users. Real-time position mapping on video monitors was added for investigator's use and information. In 1987, the use of a Global Positioning System (GPS) receiver was included in some missions. A total configuration of the system and the various sensors which can be incorporated are shown.

  16. Automatic system for ionization chamber current measurements.

    Brancaccio, Franco; Dias, Mauro S; Koskinas, Marina F


    The present work describes an automatic system developed for current integration measurements at the Laboratório de Metrologia Nuclear of Instituto de Pesquisas Energéticas e Nucleares. This system includes software (graphic user interface and control) and a module connected to a microcomputer, by means of a commercial data acquisition card. Measurements were performed in order to check the performance and for validating the proposed design.

  17. Distance and Cable Length Measurement System

    Jonay Toledo


    Full Text Available A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement.

  18. Distance and Cable Length Measurement System

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay


    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169


    Zybtsev, Y.; I. Marmut


    The study has shown that the accuracy of brakes checking by inertial stands depends upon the applied methods of measurement of braking parameters (stand slowing down, braking distance, brakes triggering time, current speed) as well as the methods of metrological checking of measuring system canals.

  20. System for measuring electric resistance skin

    V. P. Kutsenko


    Full Text Available Introduction. To measure the electrical resistance of leather frequently used system for applying testing signals from external current sources or voltage. Power testing signals the maximum limit, when they Electro studies still have a negative impact on the human body. Formulation of the problem. To achieve this task the authors conducted research and developed a system, which is based to measure electrical skin resistance (ESR responsible allocation and measurement noise variance bioelectric signal is proportional to the resistance area of research. Main body. The paper studied and developed a system, based on measuring electrical skin resistance on the identification and measurement of the noise variance from the BAP bioelectric signal that is proportional to the resistance of the investigation. A functional block diagram of an automated algorithm for converting the useful and noise signal BAP, whose range does not differ fundamentally from those of the intrinsic noise of the input elements in ESR. The proposed method will improve the accuracy of the measurements ESR without the use of test pacing signal. The simulation results and experimental studies correlate that confirms the adequacy of this method the results of experimental measurements. Conclusions. For noise voltage BAT can measure their electrical resistance without signals tested, external sources of electric current or voltage and thereby completely eliminate the harmful effect of probing. Thanks to one of the Inverting periodic noise voltages multiplied and simultaneous detection variable component switching frequency, provided the allocation and measurement noise voltage acupuncture points, which is proportional to the resistance, and the intensity of the same order or less than the intrinsic noise of the measuring system. Use as medical acupuncture needle electrodes allows to measure not only the skin but also deep resistivity, which reflects the physiological state of internal

  1. Time measurment system at the SSC

    Arai, Yasuo [National Laboratory for High Energy Physics, Ibaraki (Japan)


    A proposal of time measurement system at the SSC experiment is described. An example of a possible scheme for central tracking chambers is shown. Designs of a preamp/shaper/discri chip and a time digitizer chip are described. A method to distribute system clock and power/cooling problems are also discussed.

  2. Internal Performance Measurement Systems: Problems and Solutions

    Jakobsen, Morten; Mitchell, Falconer; Nørreklit, Hanne


    . The analysis uses and extends N rreklit's (2000) critique of the BSC by applying the concepts developed therein to contemporary research on the BSC and to the development of practice in performance measurement. The analysis is of relevance for many companies in the Asia-Pacific area as an increasing numbers......This article pursues two aims: to identify problems and dangers related to the operational use of internal performance measurement systems of the Balanced Scorecard (BSC) type and to provide some guidance on how performance measurement systems may be designed to overcome these problems...

  3. Measuring Vulnerability in the Food System

    Paloviita, Ari; Puupponen, Antti; Kortetmäki, Teea; Silvasti, Tiina


    Food system vulnerability is an emerging concept for food security policies and food supply chain management. Hence, measuring food system vulnerability is necessary for developing appropriate food security policies and managing food supply chain vulnerabilities. In this paper, we aim to clarify the development process of food system vulnerability indicators. We conducted an abducted qualitative content analysis based on public documents of various Finnish organizations, including mi...

  4. Volatility Measurements Applied to Information Systems


    LISI Levels of Information Systems Integration NPV Net Present Value OEP Organizational Execution Plans ROI Return on Investment SIGINT Signals...IT system (Stikeleather, 2013). The interoperability performance can be measured with the Levels of Information Systems Interoperability ( LISI ), (DoD CIO, 2012). There are several IT evaluation methods including net present value (NPV), ROI, information economics, cost benefit analysis, and

  5. NKS MOMS. Final report. [Mobile Measurement Systems

    Nilssen, J. [Norwegian Radiation Protection Authority (NRPA) (Norway); Aage, H.K. [Danish Emergency Management Agency (DEMA) (Denmark); Palsson, S.E. [Icelandic Radiation Safety Authority (IRSA) (Iceland)


    Mobile car-borne measurement systems are an important asset in early phase emergency response in all Nordic countries. However, through the development of the systems in the different countries, there are considerable differences between the systems developed. This complicates Nordic cooperation and mutual assistance in emergency situations. This project aimed to facilitate harmonization of mobile measurement systems between the Nordic countries. The project focused on harmonizing data formats, information exchange and measurement strategies. Although the work done was funded by each member, the project established a good platform for cooperation which will hopefully continue beyond the scope of the project. A two-day seminar was held in May 2012, where all participants presented the current status (equipment, methods used etc.), in addition to invited speakers presenting development within the field of mobile detection and in situ measurements. Exchange of experiences and information on different measurement systems and practises in use was an important part of the seminar. The seminar was followed up by a small workshop during the REFOX exercise in Lund, Sweden, September 2012. Exchange of measurement data from the exercise was facilitated through a workspace proveded by NRPA as part of the MOMS project. The work done in this project will be presented at the NordEx12 seminar in March 2013. (Author)

  6. Systems and methods for measuring component matching

    Courter, Kelly J. (Inventor); Slenk, Joel E. (Inventor)


    Systems and methods for measuring a contour match between adjacent components are disclosed. In one embodiment, at least two pressure sensors are located between adjacent components. Each pressure sensor is adapted to obtain a pressure measurement at a location a predetermined distance away from the other pressure sensors, and to output a pressure measurement for each sensor location. An output device is adapted to receive the pressure measurements from at least two pressure sensors and display the pressure measurements. In one aspect, the pressure sensors include flexible thin film pressure sensors. In accordance with other aspects of the invention, a method is provided for measuring a contour match between two interfacing components including measuring at least one pressure applied to at least one sensor between the interfacing components.

  7. Telerobotic system performance measurement: motivation and methods

    Kondraske, George V.; Khoury, George J.


    Telerobotic systems (TRSs) and shared teleautonomous systems result from the integration of multiple sophisticated modules. Procedures used in systems integration design decision-making of such systems are frequently ad hoc compared to more quantitative and systematic methods employed elsewhere in engineering. Experimental findings associated with verification and validation (V&V) are often application-specific. Furthermore, models and measurement strategies do not exist which allow prediction of overall TRS performance in a given task based on knowledge of the performance characteristics of individual subsystems. This paper introduces the use of general systems performance theory (GSPT), developed by the senior author to help resolve similar problems in human performance, as a basis for: (1) measurement of overall TRS performance (viewing all system components, including the operator, as a single entity); (2) task decomposition; (3) development of a generic TRS model; and (4) the characterization of performance of subsystems comprising the generic model. GSPT uses a resource construct to model performance and resource economic principles to govern the interface of systems to tasks. It provides a comprehensive modeling/measurement strategy applicable to complex systems including both human and artificial components. Application is presented in the context of a distributed telerobotics network (Universities Space Automation and Robotics Consortium) as a testbed. Insight into the design of test protocols which elicit application-independent data (i.e., multi-purpose or reusable) is described. Although the work is motivated by space automation and robotics challenges, it is considered to be applicable to telerobotic systems in general.

  8. Foot Plantar Pressure Measurement System: A Review

    Yufridin Wahab


    Full Text Available Foot plantar pressure is the pressure field that acts between the foot and the support surface during everyday locomotor activities. Information derived from such pressure measures is important in gait and posture research for diagnosing lower limb problems, footwear design, sport biomechanics, injury prevention and other applications. This paper reviews foot plantar sensors characteristics as reported in the literature in addition to foot plantar pressure measurement systems applied to a variety of research problems. Strengths and limitations of current systems are discussed and a wireless foot plantar pressure system is proposed suitable for measuring high pressure distributions under the foot with high accuracy and reliability. The novel system is based on highly linear pressure sensors with no hysteresis.

  9. Linear systems a measurement based approach

    Bhattacharyya, S P; Mohsenizadeh, D N


    This brief presents recent results obtained on the analysis, synthesis and design of systems described by linear equations. It is well known that linear equations arise in most branches of science and engineering as well as social, biological and economic systems. The novelty of this approach is that no models of the system are assumed to be available, nor are they required. Instead, a few measurements made on the system can be processed strategically to directly extract design values that meet specifications without constructing a model of the system, implicitly or explicitly. These new concepts are illustrated by applying them to linear DC and AC circuits, mechanical, civil and hydraulic systems, signal flow block diagrams and control systems. These applications are preliminary and suggest many open problems. The results presented in this brief are the latest effort in this direction and the authors hope these will lead to attractive alternatives to model-based design of engineering and other systems.

  10. Thermoelectric property measurements with computer controlled systems

    Chmielewski, A. B.; Wood, C.


    A joint JPL-NASA program to develop an automated system to measure the thermoelectric properties of newly developed materials is described. Consideration is given to the difficulties created by signal drift in measurements of Hall voltage and the Large Delta T Seebeck coefficient. The benefits of a computerized system were examined with respect to error reduction and time savings for human operators. It is shown that the time required to measure Hall voltage can be reduced by a factor of 10 when a computer is used to fit a curve to the ratio of the measured signal and its standard deviation. The accuracy of measurements of the Large Delta T Seebeck coefficient and thermal diffusivity was also enhanced by the use of computers.

  11. A Critique of Health System Performance Measurement.

    Lynch, Thomas


    Health system performance measurement is a ubiquitous phenomenon. Many authors have identified multiple methodological and substantive problems with performance measurement practices. Despite the validity of these criticisms and their cross-national character, the practice of health system performance measurement persists. Theodore Marmor suggests that performance measurement invokes an "incantatory response" wrapped within "linguistic muddle." In this article, I expand upon Marmor's insights using Pierre Bourdieu's theoretical framework to suggest that, far from an aberration, the "linguistic muddle" identified by Marmor is an indicator of a broad struggle about the representation and classification of public health services as a public good. I present a case study of performance measurement from Alberta, Canada, examining how this representational struggle occurs and what the stakes are.

  12. Integration of optical measurement methods with flight parameter measurement systems

    Kopecki, Grzegorz; Rzucidlo, Pawel


    During the AIM (advanced in-flight measurement techniques) and AIM2 projects, innovative modern techniques were developed. The purpose of the AIM project was to develop optical measurement techniques dedicated for flight tests. Such methods give information about aircraft elements deformation, thermal loads or pressure distribution, etc. In AIM2 the development of optical methods for flight testing was continued. In particular, this project aimed at the development of methods that could be easily applied in flight tests in an industrial setting. Another equally important task was to guarantee the synchronization of the classical measuring system with cameras. The PW-6U glider used in flight tests was provided by the Rzeszów University of Technology. The glider had all the equipment necessary for testing the IPCT (image pattern correlation technique) and IRT (infrared thermometry) methods. Additionally, equipment adequate for the measurement of typical flight parameters, registration and analysis has been developed. This article describes the designed system, as well as presenting the system’s application during flight tests. Additionally, the results obtained in flight tests show certain limitations of the IRT method as applied.

  13. High Speed Laser 3D Measurement System

    SONG Yuan-he; FAN Chang-zhou; GUO Ying; LI Hong-wei; ZHAO Hong


    Using the method of line structure light produced by a laser diode,three dimensional profile measurement is deeply researched.A hardware circuit developed is used to get the center position of light section for the improvement of the measurement speed.A double CCD compensation technology is used to improve the measurement precision. An easy and effective calibration method of the least squares to fit the parameter of system structure is used to get the relative coordinate relationship of objects and images of light section in the directions of height and axis. Sensor scanning segment by segment and layer by layer makes the measurement range expand greatly.

  14. Web based Measurement System for Solar Radiation

    Shachi Awasthi


    Full Text Available We present in this paper, the principles of the measurement system for solar radiation, and our implementation using Web based data logging concept. The photocurrent produced by Silicon PN junction is used as a solar radiation transducer, to make it more viable we have used commercially available solar panels as our transducers. Using a silicon solar cell as sensor, a low cost solar radiometer can be constructed. The photocurrent produced by solar cell is electronically tailored to be measured and stored by our web based data acquisition and monitoring system. Measurement using real solar cell array gives a good measure of actual producible energy by solar arrays. Our portable instrument can be used in remote sites and substitutes the solar monitor and integrator, Current data of solar radiation can be monitored using Ethernet interface available in all PC, Laptops. We store the data into a secure digital card which can be retrieved to plot and analyse the data. We have developed system hardware and software based on ATmega32 AVR Microcontrollers and ENC28J60 Ethernet PHY and MAC network interface chip by Microchip. So the global irradiance data are obtained after correction using the instantaneous measurement of ambient temperature which allows us to calculate the junction temperature and consequently improve the precision of measurement of our data acquisition system.

  15. Fluid-filled blood pressure measurement systems.

    Li, J K; van Brummelen, A G; Noordergraaf, A


    The performance of catheter-manometer systems for the measurement of pulsatile pressure has been evaluated by both experimental techniques and theoretical considerations. The former approach has shown, on occasion, multiple maxima in the amplitude response. The latter has been approached in a variety of ways, ranging from extreme lumping to application of transmission line theory while employing different configurations in the system's representation. Multiple maxima have also been seen, The present paper identifies the sources of the differences found and compares the relative merits of various theoretical approaches. It introduces the compliance of the system as a figure of merit and provides a simple first-order approximation formula for evaluation of the quality of a system. Damping and impedance matching to improve the system's frequency response were studied. It was found that they were not needed in a very stiff or a very compliant system, nor should one worry about the representation of such a system.

  16. Coordinate metrology accuracy of systems and measurements

    Sładek, Jerzy A


    This book focuses on effective methods for assessing the accuracy of both coordinate measuring systems and coordinate measurements. It mainly reports on original research work conducted by Sladek’s team at Cracow University of Technology’s Laboratory of Coordinate Metrology. The book describes the implementation of different methods, including artificial neural networks, the Matrix Method, the Monte Carlo method and the virtual CMM (Coordinate Measuring Machine), and demonstrates how these methods can be effectively used in practice to gauge the accuracy of coordinate measurements. Moreover, the book includes an introduction to the theory of measurement uncertainty and to key techniques for assessing measurement accuracy. All methods and tools are presented in detail, using suitable mathematical formulations and illustrated with numerous examples. The book fills an important gap in the literature, providing readers with an advanced text on a topic that has been rapidly developing in recent years. The book...

  17. Measuring system of high polymers’ pyromagnetic effect

    张永忠; 罗迎社; 粟建新; 马敏伟; 杨占宇; 张亮


    The measurement system is the main equipment of the project.Based on the characteristic of experiment system,a sensor array is designed,and used to continually acquire the global magnetic field.A scientific scheme is developed to get the signal processing and temperature compensation for nondirective weak magnetic field.The software of sampling control system is given,which is complied using C language in Labwindows/CVI.Taking computer as main engine,the system can acquire the nondirective weak magnetic field automatically and continuously use the sensor array,the change of magnetic field can be shown in real-time and intuitively.

  18. Video integrated measurement system. [Diagnostic display devices

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.


    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  19. Development of limb volume measuring system

    Bhagat, P. K.; Kadaba, P. K.


    The mechanisms underlying the reductions in orthostatic tolerance associated with weightlessness are not well established. Contradictory results from measurements of leg volume changes suggest that altered venomotor tone and reduced blood flow may not be the only contributors to orthostatic intolerance. It is felt that a more accurate limb volume system which is insensitive to environmental factors will aid in better quantification of the hemodynamics of the leg. Of the varous limb volume techniques presently available, the ultrasonic limb volume system has proven to be the best choice. The system as described herein is free from environmental effects, safe, simple to operate and causes negligible radio frequency interference problems. The segmental ultrasonic ultrasonic plethysmograph is expected to provide a better measurement of limb volume change since it is based on cross-sectional area measurements.

  20. Differential Measurement Periodontal Structures Mapping System

    Companion, John A. (Inventor)


    This invention relates to a periodontal structure mapping system employing a dental handpiece containing first and second acoustic sensors for locating the Cemento-Enamel Junction (CEJ) and measuring the differential depth between the CEJ and the bottom of the periodontal pocket. Measurements are taken at multiple locations on each tooth of a patient, observed, analyzed by an optical analysis subsystem, and archived by a data storage system for subsequent study and comparison with previous and subsequent measurements. Ultrasonic transducers for the first and second acoustic sensors are contained within the handpiece and in connection with a control computer. Pressurized water is provided for the depth measurement sensor and a linearly movable probe sensor serves as the sensor for the CEJ finder. The linear movement of the CEJ sensor is obtained by a control computer actuated by the prober. In an alternate embodiment, the CEJ probe is an optical fiber sensor with appropriate analysis structure provided therefor.

  1. Eddy Correlation Flux Measurement System Handbook

    Cook, D. R. [Argonne National Lab. (ANL), Argonne, IL (United States)


    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration. The instruments used are: • a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature) • an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO2 concentration, and • an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at one SGP EF and at the NSA CF. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes. The SEBS at one SGP and one NSA site also support upwelling and downwelling PAR measurements to qualify those two locations as Ameriflux sites.

  2. Ozone measurement systems: associated instrumentation and calibration

    J. Bellido


    Full Text Available The harmful effects produced by ozone have lead to a vast regulation to define and establish the quality goals of ambient air, based on common methods and criteria. The surveillance nets of atmospheric pollution are worldwide extended systems and the applied technology for the ozone measurement is nowadays quite standardized. The aim of this paper is to give a general view of the most common systems used in the ozone measurement in ambient air from a practical point of view. The used instrumentation and the usual calibration methods will be described.

  3. Analysis for Measurement System Using Moving Range

    MA Yi-zhong; ZHAO Feng-yu; XU Ji-chao


    In order to control and continuous improve a production process, a good measurement system is essential. The assessment of a measurement system is known as a gauge repeatability and reproducibility (R&R) analysis. In this paper, the traditional method, analysis of variance (ANOVA), is reviewed and some drawbacks are pointed out. Then a new approach is introduced to estimate R&R. In the last part, an example is presented to show the efficiency of this approach and to demonstrate its application for front-line operation.

  4. Arterial compliance measurement using a noninvasive laser Doppler measurement system

    Hast, Jukka T.; Myllylae, Risto A.; Sorvoja, Hannu; Nissilae, Seppo M.


    The aim of this study was to study the elasticity of the arterial wall using a non-invasive laser Doppler measurement system. The elasticity of the arterial wall is described by its compliance factor, which can be determined when both blood pressure and the radial velocity of the arterial wall are known. To measure radical velocity we used a self- mixing interferometer. The compliance factors were measured from six healthy volunteers, whose ages were varied from 21 to 32. Although a single volunteer's compliance factor is presented as an example, this paper treated the volunteers as a group. First, the elastic modulus, which is inversely proportional to the compliance factor, was determined. Then, an exponential curve was fitted into the measured data and a characteristic equation for the elastic modulus of the arterial wall was determined. The elastic modulus was calculated at different pressures and the results were compared to the static incremental modulus of a dog's femoral artery. The results indicate that there is a correlation between human elastic and canine static incremental modulus for blood pressures varying from 60 to 110 mmHg.

  5. High temperature hall effect measurement system design, measurement and analysis

    Berkun, Isil

    A reliable knowledge of the transport properties of semiconductor materials is essential for the development and understanding of a number of electronic devices. In this thesis, the work on developing a Hall Effect measurement system with software based data acqui- sition and control for a temperature range of 300K-700K will be described. A system was developed for high temperature measurements of materials including single crystal diamond, poly-crystalline diamond, and thermoelectric compounds. An added capability for monitor- ing the current versus voltage behavior of the contacts was used for studying the influence of ohmic and non-ohmic contacts on Hall Effect measurements. The system has been primar- ily used for testing the transport properties of boron-doped single crystal diamond (SCD) deposited in a microwave plasma-assisted chemical vapor deposition (MPCVD) reactor [1]. Diamond has several outstanding properties that are of high interest for its development as an electronic material. These include a relatively wide band gap of 5.5 (eV), high thermal conductivity, high mobility, high saturation velocity, and a high breakdown voltage. For a temperature range of 300K-700K, IV curves, Hall mobilities and carrier concentrations are shown. Temperature dependent Hall effect measurements have shown carrier concentrations from below 1017cm --3 to approximately 1021 cm--3 with mobilities ranging from 763( cm2/V s) to 0.15(cm 2/V s) respectively. Simulation results have shown the effects of single and mixed carrier models, activation energies, effective mass and doping concentrations. These studies have been helpful in the development of single crystal diamond for diode applications. Reference materials of Ge and GaAs were used to test the Hall Effect system. The system was also used to characterize polycrystalline diamond deposited on glass for electrochemical applications, and Mg2(Si,Sn) compounds which are promising candidates of low-cost, light weight and non

  6. Combat-Ready Crew Performance Measurement System.


    station, as shown in Figure 11, must permit the transformacion of data collected through the five avenues shown in Figure 9 into a digital format...Measureti\\ent System: The performance measurement system consists of the following subsystems: (1) Data Acquisition. A hybrid audio/video/photo/ digital ...processing is provided. (2) Data Processing. A general purpose digital computer with standard peripherals is required, hi addition to executive and

  7. Measurement system for SSRF pulsed magnets

    PENG Chengcheng; GU Ming; LIU Bo; OUYANG Lianhua


    This paper describes the magnetic field measurement system for pulsed magnets in SSRF.The system consists of magnetic probes,analog active integrator,oscilloscope,stepper motor and a controller.An application program based on LabVIEW has been developed as main control unit.After the magnetic field mapping of a septum magnet prototype,it is verified that the test results accord with the results of theoretical calculation and computer simuladon.

  8. Reactivity Measurement and Analysis System (RMAS-7)

    Cordero, D.; Izquierdo, J.


    This paper tries to describe the Reactivity Measurement and Analysis System 7 (RMAS-7), which is an Areva’s hardware and software solution capable of accomplishing the physic startup tests in a work shift. RMAS-7 is a modular solution designed to be a powerful, convenient data collection and analysis system based on Ethernet communication network. This last feature allows RMAS-7 to have a distributed architecture. (Author)

  9. RBS-channeling study of radiation damage in Ar{sup +} implanted CuInSe{sub 2} crystals

    Yakushev, Michael V., E-mail: [Department of Physics, SUPA, Strathclyde University, Glasgow G4 0NG (United Kingdom); Ural Federal University, Ekaterinburg 620002 (Russian Federation); Institute of Solid State Chemistry of the Urals Branch of RAS, Ekaterinburg 620990 (Russian Federation); Volkov, Vladimir A. [Ural Federal University, Ekaterinburg 620002 (Russian Federation); Mursakulov, Niyazi N.; Sabzaliyeva, Chimnaz E. [Institute of Physics, National Academy of Sciences of Azerbaijan, H.Cavid ave., 33, AZ-1143 Baku (Azerbaijan); Martin, Robert W. [Department of Physics, SUPA, Strathclyde University, Glasgow G4 0NG (United Kingdom)


    Chalcopyrite solar cells are reported to have a high tolerance to irradiation by high energy electrons or ions, but the origin of this is not well understood. This work studies the evolution of damage in Ar{sup +}-bombarded CuInSe{sub 2} single crystal using Rutherford backscattering/channeling analysis. Ar{sup +} ions of 30 keV were implanted with doses in the range from 10{sup 12} to 3 × 10{sup 16} cm{sup −2} at room temperature. Implantation was found to create two layers of damage: (1) on the surface, caused by preferential sputtering of Se and Cu atoms; (2) at the layer of implanted Ar, possibly consisting of stacking faults and dislocation loops. The damage in the second layer was estimated to be less than 2% of the theoretical prediction suggesting efficient healing of primary implantation defects.

  10. A System for Unsteady Pressure Measurements Revisited

    Tijdeman, H.; Spiering, R.M.E.J.


    An overview is presented of some recent developments in the field of the design of effective sound absorbers. The first part deals with the application of socalled coupled tubes. For this purpose use is made of a system originally applied for unsteady pressure measurements on oscillating wind tunnel

  11. Distance Measures for Information System Reengineering

    Poels, G.; Viaene, S.; Dedene, G.; Wangler, B.; Bergman, L.


    We present an approach to assess the magnitude and impact of information system reengineering caused by business process change. This approach is based on two concepts: object-oriented business modeling and distance measurement. The former concept is used to visualize changes in the business layer

  12. Party System Compactness: Measurement and Consequences

    Alvarez, R. Michael; Nagler, Jonathan


    An important property of any party system is the set of choices it presents to the electorate. In this paper we analyze the distribution of parties relative to voters in the multidimensional issue space and introduce two measures of the dispersion of the parties in the issue space relative to the vo

  13. Measuring the Equity of School Finance Systems.

    Garms, Walter I.


    Presents a new method of measuring the adequacy and equity of school finance systems using the multiple regression technique. It enables the separation of provisions for differences in district wealth from differences in tax rate, and of both of these from the differences in provision for needs and costs. (Author/IRT)

  14. The system of blade's shape measuring

    Gorbachev, Alexey A.; Korotaev, Valery V.; Apehtin, Dmitri V.


    System that will allow visual and measuring control of blades is proposed. It based on triangulation method of measurement. This method implies using of elements described below: a receiving unit, source of structured light, processing and control unit, the monitor and power supply unit. Geometrical characteristics of the system are calculated. As a result we got numbers of receiving units and sources of structured light needed to monitor blade along its entire length. Theoretical error of system measurement is calculated. It depends on distance to the object, the base between receives unit and sources of structured light, resolution and physical size of image receive. Surface of blade is not flat this fact entails changing distance from object to receive unit. So the error of measurement will be different. The interval for researching was chosen from 90 to 130 mm. Error of measurement have steady upward trend from 0,08 to 0,017 mm all period between chosen distances. The physical model of control method is developed. As a result of its working picture of illuminated metal object was obtained. The program written in MatLab processes experimental picture, find lines of structure light and calculate dislocations of it. Then use this information to make a three-dimensional model of object.

  15. An Educational Application of Distributed Measurement Systems

    J. Saliga


    Full Text Available This paper describes an educational application of distributed measurement systems for the tutored and self-educational process that has been designed and applied at the Department of Electronics and Multimedial Telecommunications, Technical University of Kosice for students at the senior level of their study. The main goal of this activity has been to improve and spread our students' knowledge beyond the traditional university education in the area of measurement and communications. The students involved do not only play a passive role in the usage of a ready-made distributed measurement system by executing a remote measurement but they have the opportunity to participate in the process of design, carrying out and supervising an own simple distributed measurement system. To simplify their task, they may either use the graphical programming environment LabVIEW or the standard ANSI C language based on the programming environment Labwindows/CVI with ready-made instrument drivers (GPIB, serial and plug-in multifunction boards and basic software skeletons. The overview of the students' resources, task-solving steps and goals as well as the present results, experience and the expected future extensions are presented, too.

  16. Multidirectional four-dimensional shape measurement system

    Lenar, Janusz; Sitnik, Robert; Witkowski, Marcin


    Currently, a lot of different scanning techniques are used for 3D imaging of human body. Most of existing systems are based on static registration of internal structures using MRI or CT techniques as well as 3D scanning of outer surface of human body by laser triangulation or structured light methods. On the other hand there is an existing mature 4D method based on tracking in time the position of retro-reflective markers attached to human body. There are two main drawbacks of this solution: markers are attached to skin (no real skeleton movement is registered) and it gives (x, y, z, t) coordinates only in those points (not for the whole surface). In this paper we present a novel multidirectional structured light measurement system that is capable of measuring 3D shape of human body surface with frequency reaching 60Hz. The developed system consists of two spectrally separated and hardware-synchronized 4D measurement heads. The principle of the measurement is based on single frame analysis. Projected frame is composed from sine-modulated intensity pattern and a special stripe allowing absolute phase measurement. Several different geometrical set-ups will be proposed depending on type of movements that are to be registered.

  17. Acoustic CT system for temperature distribution measurement

    Shinji Ohyama; Toyofumi Oga; Kazuo Oshima; Junya Takayama


    In this paper,a measurement method for crosssectional temperature distribution is addressed. A novel method based on an acoustic CT technique is proposed. Specifically,the temperature distributions are estimated using the time of flight data of several ultrasonic propagation paths. The times of the flight data contain both temperature and wind effect,and the method to select only temperature component is introduced. A filtered back projection method is applied to reconstruct the temperature distributions from the time of flight data. An experimental system was designed and fabricated to realize simultaneous temperature and wind velocity distribution measurements. Through this system,the effectiveness of the proposed measurement method is confirmed.

  18. Dust Measurements in the Outer Solar System

    Grün, E; Landgraf, M; Grün, Eberhard; Krüger, Harald; Landgraf, Markus


    Dust measurements in the outer solar system are reviewed. Only the plasma wave instrument on board Voyagers 1 and 2 recorded impacts in the Edgeworth-Kuiper belt (EKB). Pioneers 10 and 11 measured a constant dust flux of 10-micron-sized particles out to 20 AU. Dust detectors on board Ulysses and Galileo uniquely identified micron-sized interstellar grains passing through the planetary system. Impacts of interstellar dust grains onto big EKB objects generate at least about a ton per second of micron-sized secondaries that are dispersed by Poynting-Robertson effect and Lorentz force. We conclude that impacts of interstellar particles are also responsible for the loss of dust grains at the inner edge of the EKB. While new dust measurements in the EKB are in an early planning stage, several missions (Cassini and STARDUST) are en route to analyze interstellar dust in much more detail.

  19. Sustainable Food Security Measurement: A Systemic Methodology

    Findiastuti, W.; Singgih, M. L.; Anityasari, M.


    Sustainable food security measures how a region provides food for its people without endangered the environment. In Indonesia, it was legally measured in Food Security and Vulnerability (FSVA). However, regard to sustainable food security policy, the measurement has not encompassed the environmental aspect. This will lead to lack of environmental aspect information for adjusting the next strategy. This study aimed to assess Sustainable Food security by encompassing both food security and environment aspect using systemic eco-efficiency. Given existing indicator of cereal production level, total emission as environment indicator was generated by constructing Causal Loop Diagram (CLD). Then, a stock-flow diagram was used to develop systemic simulation model. This model was demonstrated for Indonesian five provinces. The result showed there was difference between food security order with and without environmental aspect assessment.

  20. Improving competitiveness through performance-measurement systems.

    Stewart, L J; Lockamy, A


    Parallels exist between the competitive pressures felt by U.S. manufacturers over the past 30 years and those experienced by healthcare providers today. Increasing market deregulation, changing government policies, and growing consumerism have altered the healthcare arena. Responding to similar pressures, manufacturers adopted a strategic orientation driven by customer needs and expectations that led them to achieve high performance levels and surpass their competition. The adoption of integrated performance-measurement systems was instrumental in these firms' success. An integrated performance-measurement model for healthcare organizations can help to blend the organization's strategy with the demands of the contemporary healthcare environment. Performance-measurement systems encourage healthcare organizations to focus on their mission and vision by aligning their strategic objectives and resource-allocation decisions with customer requirements.

  1. Low cost automated precise time measurement system

    Alpert, A.; Liposchak, P.


    The Aerospace Guidance and Metrology Center (AGMC) has the responsibility for the dissemination of Precise Time and Time Interval (PTTI) to Air Force timing systems requiring microsecond time. In order to maintain traceability to the USNO Master Clock in Washington D.C., and accomplish efficient logging of time and frequency data on individual precision clocks, a simple automatic means of acquiring precise time has been devised. The Automatic Time Interval Measurement System (ATIMS) consists of a minicomputer (8K Memory), teletype terminal, electronic counter, Loran C receiver, time base generator and locally-manufactured relay matrix panel. During the measurement process, the computer controls the relay matrix which selects for comparison 13 atomic clocks against a reference clock and the reference versus Loran C. Through use of the system teletype, the operator is able to set the system clock (hours, minutes and seconds), examine and/or modify all clock data and constants, and set measurement intervals. This is done in a conversational manner. A logic flow diagram, system schematic, source listing and software components are included in the presentation.

  2. Multi-scale biomedical systems: measurement challenges

    Summers, R.


    Multi-scale biomedical systems are those that represent interactions in materials, sensors, and systems from a holistic perspective. It is possible to view such multi-scale activity using measurement of spatial scale or time scale, though in this paper only the former is considered. The biomedical application paradigm comprises interactions that range from quantum biological phenomena at scales of 10-12 for one individual to epidemiological studies of disease spread in populations that in a pandemic lead to measurement at a scale of 10+7. It is clear that there are measurement challenges at either end of this spatial scale, but those challenges that relate to the use of new technologies that deal with big data and health service delivery at the point of care are also considered. The measurement challenges lead to the use, in many cases, of model-based measurement and the adoption of virtual engineering. It is these measurement challenges that will be uncovered in this paper.

  3. Fully automated system for pulsed NMR measurements

    Cantor, David Milton


    A system is described which places many of the complex, tedious operations for pulsed NMR experiments under computer control. It automatically optimizes the experiment parameters of pulse length and phase, and precision, accuracy, and measurement speed are improved. The hardware interface between the computer and the NMR instrument is described. Design features, justification of the choices made between alternative design strategies, and details of the implementation of design goals are presented. Software features common to all the available experiments are discussed. Optimization of pulse lengths and phases is performed via a sequential search technique called Uniplex. Measurements of the spin-lattice and spin-spin relaxation times and of diffusion constants are automatic. Options for expansion of the system are explored along with some of the limitations of the system.

  4. Torsional ultrasonic wave based level measurement system

    Holcomb, David E. (Oak Ridge, TN); Kisner, Roger A. (Knoxville, TN)


    A level measurement system suitable for use in a high temperature and pressure environment to measure the level of coolant fluid within the environment, the system including a volume of coolant fluid located in a coolant region of the high temperature and pressure environment and having a level therein; an ultrasonic waveguide blade that is positioned within the desired coolant region of the high temperature and pressure environment; a magnetostrictive electrical assembly located within the high temperature and pressure environment and configured to operate in the environment and cooperate with the waveguide blade to launch and receive ultrasonic waves; and an external signal processing system located outside of the high temperature and pressure environment and configured for communicating with the electrical assembly located within the high temperature and pressure environment.

  5. Error measuring system of rotary Inductosyn

    Liu, Chengjun; Zou, Jibin; Fu, Xinghe


    The inductosyn is a kind of high-precision angle-position sensor. It has important applications in servo table, precision machine tool and other products. The precision of inductosyn is calibrated by its error. It's an important problem about the error measurement in the process of production and application of the inductosyn. At present, it mainly depends on the method of artificial measurement to obtain the error of inductosyn. Therefore, the disadvantages can't be ignored such as the high labour intensity of the operator, the occurrent error which is easy occurred and the poor repeatability, and so on. In order to solve these problems, a new automatic measurement method is put forward in this paper which based on a high precision optical dividing head. Error signal can be obtained by processing the output signal of inductosyn and optical dividing head precisely. When inductosyn rotating continuously, its zero position error can be measured dynamically, and zero error curves can be output automatically. The measuring and calculating errors caused by man-made factor can be overcome by this method, and it makes measuring process more quickly, exactly and reliably. Experiment proves that the accuracy of error measuring system is 1.1 arc-second (peak - peak value).

  6. Web based Measurement System for Solar Radiation

    Shachi Awasthi


    Full Text Available We present in this paper, the principles of themeasurement system for solar radiation, and ourimplementation using Web based data loggingconcept.The photocurrent produced by Silicon PNjunction is used as a solar radiation transducer, tomake it more viable we have used commerciallyavailable solar panels as our transducers. Using asilicon solar cell as sensor, a low cost solarradiometer can be constructed. The photocurrentproduced by solar cell is electronically tailored to bemeasured and stored by our web based dataacquisition and monitoring system. Measurementusing real solar cell array gives a good measure ofactual producible energy by solar arrays. Ourportable instrument can be used in remote sites andsubstitutes the solar monitor and integrator,Current data of solar radiation can be monitoredusing Ethernet interface available in all PC,Laptops. We store the data into a secure digital cardwhich can be retrieved to plot and analyse the data.We have developed system hardware andsoftware based on ATmega32 AVR Microcontrollersand ENC28J60 Ethernet PHY and MAC networkinterface chip by Microchip.So the global irradiance data are obtained aftercorrection using the instantaneous measurement ofambient temperature which allows us to calculatethe junction temperature and consequently improvethe precision of measurement of our dataacquisition system

  7. Measuring and Synthesizing Systems in Probabilistic Environments

    Chatterjee, Krishnendu; Jobstmann, Barbara; Singh, Rohit


    Often one has a preference order among the different systems that satisfy a given specification. Under a probabilistic assumption about the possible inputs, such a preference order is naturally expressed by a weighted automaton, which assigns to each word a value, such that a system is preferred if it generates a higher expected value. We solve the following optimal-synthesis problem: given an omega-regular specification, a Markov chain that describes the distribution of inputs, and a weighted automaton that measures how well a system satisfies the given specification under the given input assumption, synthesize a system that optimizes the measured value. For safety specifications and measures that are defined by mean-payoff automata, the optimal-synthesis problem amounts to finding a strategy in a Markov decision process (MDP) that is optimal for a long-run average reward objective, which can be done in polynomial time. For general omega-regular specifications, the solution rests on a new, polynomial-time al...

  8. Gear Transmission Error Measurement System Made Operational

    Oswald, Fred B.


    A system directly measuring the transmission error between the meshing spur or helical gears was installed at the NASA Glenn Research Center and made operational in August 2001. This system employs light beams directed by lenses and prisms through gratings mounted on the two gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. The device is capable of resolution better than 0.1 mm (one thousandth the thickness of a human hair). The measured transmission error can be displayed in a "map" that shows how the transmission error varies with the gear rotation or it can be converted to spectra to show the components at the meshing frequencies. Accurate transmission error data will help researchers better understand the mechanisms that cause gear noise and vibration and will lead to The Design Unit at the University of Newcastle in England specifically designed the new system for NASA. It is the only device in the United States that can measure dynamic transmission error at high rotational speeds. The new system will be used to develop new techniques to reduce dynamic transmission error along with the resulting noise and vibration of aeronautical transmissions.

  9. Communications System for Down-Hole Measurements

    Mijarez-Castro Rito


    Full Text Available Progressively deeper and hotter oil wells have driven design modification that enhances the performance in sensors and downhole electronic instruments. Oil reservoirs in Mexico are located at mean depths of 6,000 m; as a consequence, the requirements for measuring thermodynamic and geophysical parameters are challenging. This paper describes a bidirectional communication system that exchanges data from a down-hole high pressure and high temperature (HP/HT measurement tool to the surface installation. The communication medium is a 7 km mono-conductor 1K22 logging cable used also as a power supply transmission line. The system consists of a proprietary downhole measurement tool, composed of a HT/HP sensor and a high temperature DSP-based electronic device, and a data acquisition equipment located in the surface installation. The system employs a communication algorithm that automatically changes the carrier frequency of the modulation technique employed, to avoid issues derived from noise interference, cable attenuation and thermal drift of the front end passive elements. The laboratory tests results provide a firm basis for testing and evaluating the system in the field.

  10. Flavor release measurement from gum model system

    Ovejero-López, I.; Haahr, Anne-Mette; van den Berg, Frans W.J.


    Flavor release from a mint-flavored chewing gum model system was measured by atmospheric pressure chemical ionization mass spectroscopy (APCI-MS) and sensory time-intensity (TI). A data analysis method for handling the individual curves from both methods is presented. The APCI-MS data are ratio...... composition can be measured by both instrumental and sensory techniques, providing comparable information. The peppermint oil level (0.5-2% w/w) in the gum influenced both the retronasal concentration and the perceived peppermint flavor. The sweeteners' (sorbitol or xylitol) effect is less apparent. Sensory...

  11. Slot Antenna for Wireless Temperature Measurement Systems

    Acar, Öncel; Jakobsen, Kaj Bjarne


    This paper presents a novel clover-slot antenna for a surface-acoustic-wave sensor based wireless temperature measurement system. The slot is described by a parametric locus curve that has the shape of a clover. The antenna is operated at high temperatures, in rough environments, and has a 43......% fractional bandwidth at the 2.4 GHz ISM-band. The slot antenna has been optimized for excitation by a passive chip soldered onto it. Measurement results are compared with simulation results and show good agreements....

  12. Eddy Correlation Flux Measurement System (ECOR) Handbook

    Cook, DR


    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration.

  13. Electric Field Quantitative Measurement System and Method

    Generazio, Edward R. (Inventor)


    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  14. Fringe Projection Measurement System in Reverse Engineering

    林朝辉; 何海涛; 郭红卫; 陈明仪; 石璇; 俞涛


    Acquisition of physical data with high precision is a key step in reverse engineering ( RE). It is an important stimulative for the progress of reverse engineering with which various digitizing devices are invented, developed and made applicable. This paper introduces a three dimensional optical measurement method based on digital fringe projection technique in RE to improve the technique through its application. A practical example is presented and the result demonstrates the applicability and feasibility of the measurement system as well as the reliability and validity of relevant methods and algorithms.

  15. ARTUS: The tune measurement system at RHIC

    Drees, A.; Brennan, M.; Connolly, R.; Michnoff, R.; DeLong, J.


    The super-conducting Relativistic Heavy Ion Collider (RHIC) with two separate rings and six combined interaction regions will provide collisions between equal and unequal heavy ion species up to Au ions in typically 60 bunches. The betatron tunes of the two beams are among the most important parameters to be measured. The tunes have to be acquired at any moment during accelerator operation and in particular during the acceleration process. At RHIC the tune measurement device (ARTUS) consists of a fast horizontal and vertical kicker magnet and a dedicated beam position monitor in each ring. The system layout is described and first experiences from operation is reported.

  16. Noncontacting Optical Measurement And Inspection Systems

    Asher, Jeffrey A.; Jackson, Robert L.


    Product inspection continues to play a growing role in the improvement of quality and reduction of scrap. Recent emphasis on precision measurements and in-process inspection have been a driving force for the development of noncontacting sensors. Noncontacting sensors can provide long term, unattended use due to the lack of sensor wear. Further, in applications where, sensor contact can damage or geometrically change the part to be measured or inspected, noncontacting sensors are the only technical approach available. MTI is involved in the development and sale of noncontacting sensors and custom inspection systems. This paper will review the recent advances in noncontacting sensor development. Machine vision and fiber optics sensor systems are finding a wide variety of industrial inspection applications. This paper will provide detailed examples of several state-of-the-art applications for these noncontacting sensors.

  17. Plume Measurement System (PLUMES) Calibration Experiment


    Atle Lohrmann SonTek, Inc. 7940 Silverton Avenue, No. 105 San Diego, California 92126 and Craig Huhta JIMAR University of Hawaii, Honolulu, Hawaii 96822...Measurement System (PLUMES) Calibration Experiment by Age Lohrmann SonTek, Inc. 7940 Silverton Avenue, No. 105 San Diego, CA 92126 Craig Huhta JIMAR...PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) &. PERFORMING ORGANIZATION SonTek, Inc., 7940 Silverton Avenue, No. 105, San Diego, CA 92126 REPORT NUMBER

  18. Improved control of delayed measured systems

    Claussen, Jens Christian; Schuster, Heinz Georg


    In this paper, we address the question of how the control of delayed measured chaotic systems can be improved. Both unmodified Ott-Grebogi-Yorke control and difference control can be successfully applied only for a certain range of Lyapunov numbers depending on the delay time. We show that this limitation can be overcome by at least two classes of methods, namely, by rhythmic control and by the memory methods of linear predictive logging control and memory difference control.

  19. Optical tomography system for laboratory turbulence measurements

    McMackin, Lenore J.; Pierson, Robert E.; Hugo, Ronald J.; Truman, C. Randall


    We describe the design and operation of a high speed optical tomography system for measuring 2D images of a dynamic phase object at a rate of 5 kHz. Data from a set of eight Hartmann wavefront sensors is back-projected to produce phase images showing the details of the inner structure of a heated air flow. Series of reconstructions at different downstream locations illustrate the development of flow structure and the effect of acoustic flow forcing.

  20. Performance Measurement Systems: A Best Practices Study


    Vollman , 1990, p. 37). The use of self-directed work teams in this study, to make changes to the Performance Measurement Systems, using personnel from all...strategy and goals of the organization (Atkinson, et al, 1991, p. 86; Ernst and Young, 1990, p. 163). And as Dixon, Nanni and Vollman (1991) point out, a...Reaaining the Productive Edae, Massachusetts Institute of Technology, 1990. Dixon, J.R., Nanni, A.J., and Vollman , T.E., The N Performancge Challenge

  1. A portable magnetic induction measurement system (PIMS).

    Cordes, Axel; Foussier, Jérôme; Pollig, Daniel; Leonhardt, Steffen


    For contactless monitoring of ventilation and heart activity, magnetic induction measurements are applicable. As the technique is harmless for the human body, it is well suited for long-term monitoring solutions, e.g., bedside monitoring, monitoring of home care patients, and the monitoring of persons in critical occupations. For such settings, a two-channel portable magnetic induction system has been developed, which is small and light enough to be fitted in a chair or bed. Because demodulation, control, and filtering are implemented on a front-end digital signal processor, a PC is not required (except for visualization/data storage during research and development). The system can be connected to a local area network (LAN) or wireless network (WiFi), allowing to connect several devices to a large monitoring system, e.g., for a residential home for the elderly or a hospital with low-risk patients not requiring standard ECG monitoring. To visualize data streams, a Qt-based (Qt-framework by Nokia, Espoo, Finland) monitoring application has been developed, which runs on Netbook computers, laptops, or standard PCs. To induce and measure the magnetic fields, external coils and amplifiers are required. This article describes the system and presents results for monitoring respiration and heart activity in a (divan) bed and for respiration monitoring in a chair. Planar configurations and orthogonal coil setups were examined during the measurement procedures. The measurement data were streamed over a LAN to a monitoring PC running Matlab (The MathWorks Inc, Natick, MA, USA).

  2. Improvement an enterprises marketing performance measurement system

    Stanković Ljiljana


    Full Text Available Business conditions in which modern enterprises do business are more and more complex. The complexity of the business environment is caused by activities of external and internal factors, which imposes the need for the turn in management focus. One of key turns is related to the need of adaptation and development of new business performance evaluation systems. The evaluation of marketing contribution to business performance is very important however a complex task as well. The marketing theory and practice indicates the need for developing adequate standards and systems for evaluating the efficiency of marketing decisions. The better understanding of marketing standards and ways that managers use is a very important factor that affects the efficiency of strategic decision-making. The paper presents the results of researching the way in which managers perceive and apply marketing performance measures. The data that were received through the field research sample enabled the consideration of the managers' attitudes on practical ways of implementing marketing performance measurement and identifying measures that managers imply as used mostly in business practice.

  3. New Gear Transmission Error Measurement System Designed

    Oswald, Fred B.


    The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.


    Rowe, Nathan C [ORNL; Younkin, James R [ORNL; Smith, Steven E [ORNL; Chapman, Jeffrey Allen [ORNL; Dunn, Michael E [ORNL; Stewart, Scott L [ORNL


    SNAPSHOT is a software platform designed to eventually replace Holdup Measurement System 4 (HMS 4), which is the current state-of-the-art for acquisition and analysis of nondestructive assay measurement data for in situ nuclear materials, holdup, in support of criticality safety and material control and accounting. HMS 4 is over 10 years old and is currently unsustainable due to hardware and software incompatibilities that have arisen from advances in detector electronics, primarily updates to multi-channel analyzers (MCAs), and both computer and handheld operating systems. SNAPSHOT is a complete redesign of HMS 4 that addresses the issue of compatibility with modern MCAs and operating systems and that is designed with a flexible architecture to support long-term sustainability. It also provides an updated and more user friendly interface and is being developed under an NQA 1 software quality assurance (SQA) program to facilitate site acceptance for safety-related applications. This paper provides an overview of the SNAPSHOT project including details of the software development process, the SQA program, and the architecture designed to support sustainability.

  5. Measurements of system sharpness for two digital breast tomosynthesis systems.

    Marshall, N W; Bosmans, H


    The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF(0.50)) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm(-1) for the Inspiration system and from 2.50 to 1.20 mm(-1) for the Dimensions unit. The maximum deviation of measured MTF(0.50) from the calculated value was 13%. MTF(0.50) measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm(-1) for the Inspiration system and from 2.21 to 1.31 mm(-1) for the Dimensions system. The full-width half-maximum for the in

  6. Turbidity Measurement Using An Optical Tomography System

    Sallehuddin Bin Ibrahim


    Turbidity is used to describe water quality and it can be caused by the presence of suspended particles and organic matter such as algae, clay and silt. The measurement of turbidity level of water is vital to domestic water supplies since it is related to public health and water treatment process. This paper presents an investigation on an optical tomography system to estimate the turbidity level in a sample of water. The optical sensors consist of infrared light-emitting diodes (LED) as tran...

  7. Seafloor earthquake measurement system, SEMS IV

    Platzbecker, M.R.; Ehasz, J.P.; Franco, R.J.


    Staff of the Telemetry Technology Development Department (2664) have, in support of the U.S. Interior Department Mineral Management Services (MMS), developed and deployed the Seafloor Earthquake Measurement System IV (SEMS IV). The result of this development project is a series of three fully operational seafloor seismic monitor systems located at offshore platforms: Eureka, Grace, and Irene. The instrument probes are embedded from three to seven feet into the seafloor and hardwired to seismic data recorders installed top side at the offshore platforms. The probes and underwater cables were designed to survive the seafloor environment with an operation life of five years. The units have been operational for two years and have produced recordings of several minor earthquakes in that time. Sandia Labs will transfer operation of SEMS IV to MMS contractors in the coming months. 29 figs., 25 tabs.

  8. Turbidity Measurement Using An Optical Tomography System

    Sallehuddin Bin Ibrahim


    Full Text Available Turbidity is used to describe water quality and it can be caused by the presence of suspended particles and organic matter such as algae, clay and silt. The measurement of turbidity level of water is vital to domestic water supplies since it is related to public health and water treatment process. This paper presents an investigation on an optical tomography system to estimate the turbidity level in a sample of water. The optical sensors consist of infrared light-emitting diodes (LED as transmitters and photodiodes as the receivers where the projections of the sensors are designed in fan beam mode. The system was tested using a vertical flow pipe. The Independent Component Analysis (ICA method was used to display the concentration profile. Results obtained proved that the technique can provide the concentration profile representing the turbidity level of water.

  9. Material permeance measurement system and method

    Hallman, Jr., Russell Louis; Renner, Michael John [Oak Ridge, TN


    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  10. Design of computerized unbalance measuring system

    Karunakara, K.; Nambudiri, P.V.V.; Aradhya, S.; Kumar, E.M.; Channakeshava [Central Power Research Inst., Bangalore (India)


    In complex network, the connected loads may be of single phase or three phase. Increased trend of traction loads, Arc furnace load and thyristor devices necessitates check for voltage quality. Harmonics, flicker and unbalance are some of the factors influencing the voltage quality. Evaluation of voltage quality and applying correction, if required, are to be made depending upon the situation prevailing in the system. Under certain load conditions like arc furnace, traction and thyristor devices, the unbalance factor may vary every few cycles and for the unbalance correction, devices like static Var compensator (SVC) have to be used. These correcting devices have some time lag to effect corrections, thus measurement based on short time information will not give the true picture. To avoid erroneous conclusions from the short term data, an instrument based on an integrated value over fairly long duration was designed and fabricated by CPRI. This paper discusses about the design and calibration of the instrument and presents typical measured data on an electrical system by using this instrument.

  11. Behavioral System Feedback Measurement Failure: Sweeping Quality under the Rug

    Mihalic, Maria T.; Ludwig, Timothy D.


    Behavioral Systems rely on valid measurement systems to manage processes and feedback and to deliver contingencies. An examination of measurement system components designed to track customer service quality of furniture delivery drivers revealed the measurement system failed to capture information it was designed to measure. A reason for this…

  12. Units of measure in clinical information systems.

    Schadow, G; McDonald, C J; Suico, J G; Föhring, U; Tolxdorff, T


    The authors surveyed existing standard codes for units of measures, such as ISO 2955, ANSI X3.50, and Health Level 7's ISO+. Because these standards specify only the character representation of units, the authors developed a semantic model for units based on dimensional analysis. Through this model, conversion between units and calculations with dimensioned quantities become as simple as calculating with numbers. All atomic symbols for prefixes and units are defined in one small table. Huge permutated conversion tables are not required. This method is also simple enough to be widely implementable in today's information systems. To promote the application of the method the authors provide an open-source implementation of this method in JAVA. All existing code standards for units, however, are incomplete for practical use and require substantial changes to correct their many ambiguities. The authors therefore developed a code for units that is much more complete and free from ambiguities.

  13. SNR Degradation in Undersampled Phase Measurement Systems

    David Salido-Monzú


    Full Text Available A wide range of measuring applications rely on phase estimation on sinusoidal signals. These systems, where the estimation is mainly implemented in the digital domain, can generally benefit from the use of undersampling to reduce the digitizer and subsequent digital processing requirements. This may be crucial when the application characteristics necessarily imply a simple and inexpensive sensor. However, practical limitations related to the phase stability of the band-pass filter prior digitization establish restrictions to the reduction of noise bandwidth. Due to this, the undersampling intensity is practically defined by noise aliasing, taking into account the amount of signal-to-noise ratio (SNR reduction caused by it considering the application accuracy requirements. This work analyzes the relationship between undersampling frequency and SNR reduction, conditioned by the stability requirements of the filter that defines the noise bandwidth before digitization. The effect of undersampling is quantified in a practical situation where phase differences are measured by in-phase and quadrature (I/Q demodulation for an infrared ranging application.

  14. Free-form surface measuring method based on optical theodolite measuring system

    Yu, Caili


    The measurement for single-point coordinate, length and large-dimension curved surface in industrial measurement can be achieved through forward intersection measurement by the theodolite measuring system composed of several optical theodolites and one computer. The measuring principle of flexible large-dimension three-coordinate measuring system made up of multiple (above two) optical theodolites and composition and functions of the system have been introduced in this paper. Especially for measurement of curved surface, 3D measured data of spatial free-form surface is acquired through the theodolite measuring system and the CAD model is formed through surface fitting to directly generate CAM processing data.

  15. 22 CFR 226.15 - Metric system of measurement.


    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Metric system of measurement. 226.15 Section....S. NON-GOVERNMENTAL ORGANIZATIONS Pre-award Requirements § 226.15 Metric system of measurement. (a...) declares that the metric system is the preferred measurement system for U.S. trade and commerce....

  16. 45 CFR 74.15 - Metric system of measurement.


    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Metric system of measurement. 74.15 Section 74.15... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 74.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The...

  17. 22 CFR 145.15 - Metric system of measurement.


    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Metric system of measurement. 145.15 Section... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade...

  18. 15 CFR 14.15 - Metric system of measurement.


    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Metric system of measurement. 14.15... COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 14.15 Metric system of measurement. The Metric Conversion... system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  19. 36 CFR 1210.15 - Metric system of measurement.


    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Metric system of measurement... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade...

  20. 34 CFR 74.15 - Metric system of measurement.


    ... 34 Education 1 2010-07-01 2010-07-01 false Metric system of measurement. 74.15 Section 74.15... Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for...

  1. High speed high dynamic range high accuracy measurement system

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng


    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  2. Toward a formal theory of the measuring system

    Battista Rossi, Giovanni; Crenna, Francesco


    Measurement aims at obtaining a numerical description of objects/events/persons in real world by means of a measuring system. Measurement is widely used as a key way for obtaining high quality information from the real world. across disciplines. In the present day. there is growing consensus in holding that measurement is characterized by the use of something that qualifies as a “measuring system”. Therefore. we discuss sufficient conditions for an empirical system to qualify as a measuring system.


    M. Ćurić


    Full Text Available Measuring system of adverse weather phenomena. The adverse weather phenomena in nowadays are becoming an extraordinary problem in human life and human activity. Therefore, it seems very important to know the thresholds of adverse weather phenomena. These thresholds can be calculated in different ways, but some experience has shown that for weather elements which departures from normal follow the normal distribution suits to use the Gaussian curve of frequency distribution (temperature and pressure. For such weather elements the normal curve of frequency distribution may be used for classification of thresholds. For weather elements which departures do not depend on such a frequency distribution configuration (precipitation amounts may be used a decile method. For wind speed thresholds, the Beaufort scale units can be used for calculation. In this paper the threshold scales for four basic weather elemnts are presented. All these scales contain four steps each. They are defined: normal, above normal, much above normal and extraordinary above normal or normal, below normal, much below normal and extraordinary below normal. The examples by observations of Meteorological Observatory in Belgrade are presented.

  4. The Galileo System of Measurement: Preliminary Evidence for Precision, Stability, and Equivalance to Traditional Measures

    Gillham, James; Woelfel, Joseph


    Describes the Galileo system of measurement operations including reliability and validity data. Illustrations of some of the relations between Galileo measures and traditional procedures are provided. (MH)

  5. Calibration and Validation of Measurement System

    Kofoed, Jens Peter; Riemann, Sven; Knapp, Wilfried

    The report deals with the calibration of the measuring equipment on board the Wave Dragon, Nissum Bredning prototype.......The report deals with the calibration of the measuring equipment on board the Wave Dragon, Nissum Bredning prototype....

  6. Accounting System and Financial Performance Measurements

    Halíř, Zbyněk


    The paper concerns measuring and reporting of financial performance of an enterprise. Currently increasing emphasis is placed on performance measurement and management. Within performance measurement and management in general the role of financial performance is becoming increasingly important. The paper is concerned with measuring and reporting of financial performance of an enterprise primarily from manager’s point of view. In its first part it deals primarily with the connection between th...

  7. Gas exchange measurements in natural systems

    Broecker, W.S.; Peng, T.H.


    Direct knowledge of the rates of gas exchange in lakes and the ocean is based almost entirely on measurements of the isotopes /sup 14/C, /sup 222/Rn and /sup 3/He. The distribution of natural radiocarbon has yielded the average rate of CO/sub 2/ exchange for the ocean and for several closed basin lakes. That of bomb produced radiocarbon has been used in the same systems. The /sup 222/Rn to /sup 226/Ra ratio in open ocean surface water has been used to give local short term gas exchange rates. The radon method generally cannot be used in lakes, rivers, estuaries or shelf areas because of the input of radon from sediments. A few attempts have been made to use the excess /sup 3/He produced by decay of bomb produced tritium in lakes to give gas transfer rates. The uncertainty in the molecular diffusivity of helium and in the diffusivity dependence of the rate of gas transfer holds back the application of this method. A few attempts have been made to enrich the surface waters of small lakes with /sup 226/Ra and /sup 3/H in order to allow the use of the /sup 222/Rn and /sup 3/He methods. While these studies give broadly concordant results, many questions remain unanswered. The wind velocity dependence of gas exchange rate has yet to be established in field studies. The dependence of gas exchange rate on molecular diffusivity also remains in limbo. Finally, the degree of enhancement of CO/sub 2/ exchange through chemical reactions has been only partially explored. 49 references, 2 figures, 2 tables.

  8. Measurement system for resistive metal oxide sensors matrix

    Róg, Piotr; Rydosz, Artur; Brudnik, Andrzej


    The measurement system for laboratory array of gas sensors was constructed. The system can be used to measure the response characteristic of resistive metal oxide (MOx) gas sensors. Proposed system is flexible and reconfigurable easy, to perform high and low resistivity measurements.

  9. 32 CFR 22.530 - Metric system of measurement.


    ... CFR, 1991 Comp., p. 343), states that: (1) The metric system is the preferred measurement system for U... 32 National Defense 1 2010-07-01 2010-07-01 false Metric system of measurement. 22.530 Section 22... of measurement. (a) Statutory requirement. The Metric Conversion Act of 1975, as amended by...

  10. 40 CFR 30.15 - Metric system of measurement.


    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Metric system of measurement. 30.15... measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205), declares that the metric system is the preferred measurement system for U.S. trade and commerce. The...

  11. Measuring Force System Set-Up

    Cornelia Victoria Anghel


    Full Text Available In this paper, are presented the results of cutting force and torque measurements were undertaken by a 4-axis 9272 KISTLER dynamometer. The DynoWare software was used for processing of the measurements. We can conclude that the values of torque, cutting force were higher compared to dry drilling, as we expected.

  12. Patient-Reported Outcome Measures in Systemic Sclerosis (Scleroderma).

    Pellar, Russell E; Tingey, Theresa M; Pope, Janet Elizabeth


    Scleroderma (systemic sclerosis) is a rare autoimmune connective tissue disease that can damage multiple organs and reduce quality of life. Patient-reported outcome measures capture the patient's perspective. Some measures are specific to systemic sclerosis and others are general. Patient-reported outcomes in systemic sclerosis are important to aid in understanding the impact of systemic sclerosis on patients.

  13. On System Complexity: Identification, Measurement, and Management

    Casti, J.L.


    Attempts to axiomatize and formalize system complexity all leave a feeling of basic incompleteness and a sense of failure to grasp important aspects of the problem. This paper examines some of the root causes of these failures and outlines a framework for the consideration of complexity as an implicate, rather than explicate, property of systems in interaction.

  14. Methods and systems for measuring anions

    Masih, Dilshad


    Embodiments of the present disclosure provide for methods for detecting the presence and/or concentration of anions in a solution, systems for detecting the presence and/or concentration of anions in a solution, anion sensor systems, and the like.

  15. Measuring cell identity in noisy biological systems

    Kenneth D Birnbaum; Kussell, Edo


    Global gene expression measurements are increasingly obtained as a function of cell type, spatial position within a tissue and other biologically meaningful coordinates. Such data should enable quantitative analysis of the cell-type specificity of gene expression, but such analyses can often be confounded by the presence of noise. We introduce a specificity measure Spec that quantifies the information in a gene's complete expression profile regarding any given cell type, and an uncertainty me...


    Hennig, Wolfgang; Warburton, William K.; Fallu-Labruyere, A.; Sabourov, K.; Cooper, Matthew W.; McIntyre, Justin I.; Gleyzer, A.; Bean, Marc; Korpach, E.; Ungar, R. Kurt; Zhang, W.; Mekarski, P.; Ward, Rebecca; Biegalski, S.; Haas, Derek A.


    Many of the radioxenon detector systems used in the International Monitoring System and in other applications employ beta/gamma coincidence detection to achieve high sensitivity. In these systems, the coincidence detection is implemented by requiring simultaneous signals from separate beta and gamma detectors. While very sensitive to small amounts of radioxenon, this approach requires careful calibration and gain matching of several detectors and photomultiplier tubes. An alternative approach is the use of a phoswich detector in which beta-gamma coincidences are detected by pulse shape analysis. The phoswich requires only a single photomultiplier tube and thus is easier to set up and calibrate, and can be assembled into a more compact and robust system. In the past, we have developed a COTS detector system, named PhosWatch, which consists of a CsI(Tl)/BC-404 phoswich detector, digital readout electronics, and on-board software to perform the pulse shape analysis. Several units of this system have been manufactured and are now evaluated at several radioxenon research laboratories. In this paper, we will report results from production tests and some of the evaluations, including a side-by-side comparison of a SAUNA detector and a PhosWatch system using atmospheric radioxenon samples. In addition, we will show initial results obtained with a higher speed version of the readout electronics, digitizing at 500 MHz and thus able to better resolve the fast pulses from the BC-404.

  17. Design of MEMS accelerometer based acceleration measurement system for automobiles

    Venkatesh, K. Arun; Mathivanan, N.


    Design of an acceleration measurement system using a MEMS accelerometer to measure acceleration of automobiles in all the three axes is presented. Electronic stability control and anti-lock breaking systems in automobiles use the acceleration measurements to offer safety in driving. The system uses an ARM microcontroller to quantize the outputs of accelerometer and save the measurement data on a microSD card. A LabVIEW program has been developed to analyze the longitudinal acceleration measurement data and test the measurement system. Random noises generated and added with measurement data during measurement are filtered by a Kalman filter implemented in LabVIEW. Longitudinal velocity of the vehicle is computed from the measurement data and displayed on a graphical chart. Typical measurement of velocity of a vehicle at different accelerations and decelerations is presented.

  18. Study of the helicopter blade running elevation measurement system


    Helicopter blade running elevation measurement is an important measure target in helicopter blade dynamic balance experimentation. The elevation influences the helicopter's security and other performance capabilities. In testing, however, it has been difficult to measure the elevation when the rotor reaches high speeds. To get a simple, fast and highly accurate measurement system, photo electricity technology was applied to measuring the blade running elevation. Discussed is the measurement principle of blade running elevation, the design of the measurement system and analysis of the measurement precision.

  19. Distributed Force and Moment Measurement System Project

    National Aeronautics and Space Administration — The structural design of aircraft and their propulsion systems is a challenging task that requires accurate, flexible ground facilities capable of operating over the...

  20. An automated radar-signature measurement system

    Kruse, Juergen

    The design and operation of an automated measurement facility permitting determination of radar cross sections and location and characterization of scattering centers on aircraft models up to 4.5 m in length are described and illustrated with diagrams, drawings, graphs, and photographs. The facility comprises a 15 x 5.8 x 3.8-m measurement chamber, a rotating platform with maximum load 270 kg and elevation range from -5 to +35 deg (precision 0.1 deg), a tunable broadband 2-18-GHz transmitter, a phase-sensitive receiver, and control and data-processing computers. The analytical techniques employed to correct for measurement errors and to resolve scattering centers both longitudinally and transversely (two-dimensional representation) are explained and demonstrated. The facility is currently being used to develop and evaluate stealth-type aircraft designs.

  1. Hyperbolic contraction measuring systems for extensional flow

    Nyström, M.; Tamaddon Jahromi, H. R.; Stading, M.; Webster, M. F.


    In this paper an experimental method for extensional measurements on medium viscosity fluids in contraction flow is evaluated through numerical simulations and experimental measurements. This measuring technique measures the pressure drop over a hyperbolic contraction, caused by fluid extension and fluid shear, where the extensional component is assumed to dominate. The present evaluative work advances our previous studies on this experimental method by introducing several contraction ratios and addressing different constitutive models of varying shear and extensional response. The constitutive models included are those of the constant viscosity Oldroyd-B and FENE-CR models, and the shear-thinning LPTT model. Examining the results, the impact of shear and first normal stress difference on the measured pressure drop are studied through numerical pressure drop predictions. In addition, stream function patterns are investigated to detect vortex development and influence of contraction ratio. The numerical predictions are further related to experimental measurements for the flow through a 15:1 contraction ratio with three different test fluids. The measured pressure drops are observed to exhibit the same trends as predicted in the numerical simulations, offering close correlation and tight predictive windows for experimental data capture. This result has demonstrated that the hyperbolic contraction flow is well able to detect such elastic fluid properties and that this is matched by numerical predictions in evaluation of their flow response. The hyperbolical contraction flow technique is commended for its distinct benefits: it is straightforward and simple to perform, the Hencky strain can be set by changing contraction ratio, non-homogeneous fluids can be tested, and one can directly determine the degree of elastic fluid behaviour. Based on matching of viscometric extensional viscosity response for FENE-CR and LPTT models, a decline is predicted in pressure drop for

  2. Hyperbolic contraction measuring systems for extensional flow

    Nyström, M.; Tamaddon Jahromi, H. R.; Stading, M.; Webster, M. F.


    In this paper an experimental method for extensional measurements on medium viscosity fluids in contraction flow is evaluated through numerical simulations and experimental measurements. This measuring technique measures the pressure drop over a hyperbolic contraction, caused by fluid extension and fluid shear, where the extensional component is assumed to dominate. The present evaluative work advances our previous studies on this experimental method by introducing several contraction ratios and addressing different constitutive models of varying shear and extensional response. The constitutive models included are those of the constant viscosity Oldroyd-B and FENE-CR models, and the shear-thinning LPTT model. Examining the results, the impact of shear and first normal stress difference on the measured pressure drop are studied through numerical pressure drop predictions. In addition, stream function patterns are investigated to detect vortex development and influence of contraction ratio. The numerical predictions are further related to experimental measurements for the flow through a 15:1 contraction ratio with three different test fluids. The measured pressure drops are observed to exhibit the same trends as predicted in the numerical simulations, offering close correlation and tight predictive windows for experimental data capture. This result has demonstrated that the hyperbolic contraction flow is well able to detect such elastic fluid properties and that this is matched by numerical predictions in evaluation of their flow response. The hyperbolical contraction flow technique is commended for its distinct benefits: it is straightforward and simple to perform, the Hencky strain can be set by changing contraction ratio, non-homogeneous fluids can be tested, and one can directly determine the degree of elastic fluid behaviour. Based on matching of viscometric extensional viscosity response for FENE-CR and LPTT models, a decline is predicted in pressure drop for

  3. Measurement system analysis for binary tests

    Akkerhuis, T.S.


    Binary tests classify items into two categories such as reject/accept, positive/negative or guilty/innocent. A binary test’s proneness to measurement error is usually expressed in terms of the misclassification probabilities FAP (false acceptance probability) and FRP (false rejection probability).

  4. Creep measurements on curing epoxy systems

    Kammer, Charlotte; Szabo, Peter


    The chemical curing of a stoichiometric mixture of the diglycidyl ether of bisphenol A and a 1,3-bis-(aminomethyl)-cyclohexane is studied.Creep experiments are combined with measurements in a Differential Scanning Calorimeter (DSC) to determine the change in bulk viscosity due to network formation....

  5. Measuring the ROI on Knowledge Management Systems.

    Wickhorst, Vickie


    Defines knowledge management and corporate portals and provides a model that can be applied to assessing return on investment (ROI) for a knowledge management solution. Highlights include leveraging knowledge in an organization; assessing the value of human capital; and the Intellectual Capital Performance Measurement Model. (LRW)

  6. Measures of Autonomic Nervous System Regulation


    Tension-Release Practices Trauma Resiliency Model (TRM)* X* X* Trauma and Tension Releasing Exercises (TRE) Yoga (Asana...Mindfulness Based Stress Reduction (MBSR) Yoga Nidra (iRest) X X *Study currently in progress utilizing these measures 7...pulse oximeter have the benefit of being more portable; they do not require a trained technician and are more durable than the traditional EKG. The

  7. Creep measurements on curing epoxy systems

    Kammer, Charlotte; Szabo, Peter


    The chemical curing of a stoichiometric mixture of the diglycidyl ether of bisphenol A and a 1,3-bis-(aminomethyl)-cyclohexane is studied.Creep experiments are combined with measurements in a Differential Scanning Calorimeter (DSC) to determine the change in bulk viscosity due to network formation....

  8. 38 CFR 49.15 - Metric system of measurement.


    ... measurement. 49.15 Section 49.15 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The...

  9. Displacement measurement system for inverters using computer micro-vision

    Wu, Heng; Zhang, Xianmin; Gan, Jinqiang; Li, Hai; Ge, Peng


    We propose a practical system for noncontact displacement measurement of inverters using computer micro-vision at the sub-micron scale. The measuring method of the proposed system is based on a fast template matching algorithm with an optical microscopy. A laser interferometer measurement (LIM) system is built up for comparison. Experimental results demonstrate that the proposed system can achieve the same performance as the LIM system but shows a higher operability and stability. The measuring accuracy is 0.283 μm.

  10. Development of radiation detection and measurement systems

    Moon, B. S.; Ham, C. S.; Chung, C. E. and others


    This report contains descriptions on the following six items. The first item is the result of a study on CsI(TI) crystals with their light emitting characteristics and the result of a study on plastic scintillators. The second item is the result of a study on advanced radiation detectors and includes experiments for the effect of using a Compton suppressor with an HPGe detector. For the third item, we describe the results of a design work done using EGS4 for a thickness gauge, a density gauge, and a level gauge. The fourth item contains descriptions on the prototype circuit systems developed for a level gauge, a thickness gauge, and for a survey meter. The fifth part contains the computed tomography algorithm and a prototype scanning system developed for a CT system. As the sixth and the last item, we describe the prototype high precision heat source and the prototype heat-voltage converter which we have designed and fabricated.

  11. Beam Current Measurement and Adjustment System on AMS

    WUShao-yong; HEMING; SUSheng-yong; WANGZhen-jun; JIANGShan


    The beam current measurement and adjustment system of HI-13 tandem accelerator mass spectrometry detector system is consisted of the faraday cup, fluorescent target and a series of adjustable vertical slits(Fig. 1). The system's operation is very complicated and the transmission is low for the old system. A new system is instalated for improvement. We put the adjustable vertical slit, Faraday cup.

  12. Solar energy control system. [temperature measurement

    Currie, J. R. (Inventor)


    A solar energy control system for a hot air type solar energy heating system wherein thermocouples are arranged to sense the temperature of a solar collector, a space to be heated, and a top and bottom of a heat storage unit is disclosed. Pertinent thermocouples are differentially connected together, and these are employed to effect the operation of dampers, a fan, and an auxiliary heat source. In accomplishing this, the differential outputs from the thermocouples are amplified by a single amplifier by multiplexing techniques. Additionally, the amplifier is corrected as to offset by including as one multiplex channel a common reference signal.

  13. The Strategic Systems Therapies: Measuring the Models.

    Rohrbaugh, Michael

    As family therapy becomes a serious intellectual disipline, the relationships among its leading variations require closer examination. To examine similarities and differences among four closely related approaches (brief, problem-focused therapy; structural family therapy; strategic family therapy; and systemic family therapy) and to determine if…

  14. Measuring the global domain name system

    Casalicchio, E.; Caselli, M.; Coletta, A.; Shen, Xuemin


    The Internet is a worldwide distributed critical infrastructure, and it is composed of many vital components. While IP routing is the most important service, today the Domain Name System can be classified as the second most important, and has been defined as a critical infrastructure as well. DNS en

  15. Structure analysis and performance measurement of Chinese health delivery system


    Objective: Although evidence has already demonstrated that the performance of Health Delivery System (HDS) varies widely across nations, relatively little is known about the factors that give rise to these variations and the key point to improve the performance besides adjusting system structure. By setup of HDS performance measurement system on the base of association of financial, social, and environmental characteristics, we construct system dynamic model of HDS to simulate the invention policies. Methods:Performance measures were collected from HDS in 31 regions of China and combined with secondary data sources. Multivariate, linear, nonlinear regression and factor analysis models were used to estimate associations between system characteristics and the performance. Results: Performance varied significantly with the size, financial resources and organizational structure of HDS. Performance measurement system of health delivery system was developed to give the rank of all Chinese regions. Conclusion: Performance measurement system of HDS is the basic of HDS modeling by system dynamic.

  16. Measuring the orthogonality error of coil systems

    Heilig, B.; Csontos, A.; Pajunpää, K.; White, Tim; St. Louis, B.; Calp, D.


    Recently, a simple method was proposed for the determination of pitch angle between two coil axes by means of a total field magnetometer. The method is applicable when the homogeneous volume in the centre of the coil system is large enough to accommodate the total field sensor. Orthogonality of calibration coil systems used for calibrating vector magnetometers can be attained by this procedure. In addition, the method can be easily automated and applied to the calibration of delta inclination–delta declination (dIdD) magnetometers. The method was tested by several independent research groups, having a variety of test equipment, and located at differing geomagnetic observatories, including: Nurmijärvi, Finland; Hermanus, South Africa; Ottawa, Canada; Tihany, Hungary. This paper summarizes the test results, and discusses the advantages and limitations of the method.

  17. Measurement System for Energetic Materials Decomposition


    5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 5c. PROGRAM ELEMENT NUMBER 5b. GRANT NUMBER 5a. CONTRACT NUMBER Form Approved OMB NO...acknowledge ARO support from the start of the project to the date of this printing. List the papers, including journal references, in the following...The proposal sought funds to purchase a thermal analysis system which included thermogravametric analysis (TGA), differential scanning calorimetry

  18. System for water level measurement based on pressure transducer

    Paczesny, Daniel; Marzecki, Michał; Woyke, Michał; Tarapata, Grzegorz


    The paper reports system for water level measurement, which is designed to be used for measuring liquid levels in the tanks of an autonomous industrial cleaning robot. The selected method of measurement utilized by the designed system is based on pressure measurement. Such system is insensitive on vibrations, foams presence and liquid impurities. The influences of variable pressure on the measurements were eliminated by utilizing the differential method and as well as the system design. The system is capable of measuring water level in tanks up to 400 mm of height with accuracy of about 2,5%. The system was tested in a container during filling and emptying with various liquids. Performed tests exhibited the linearity of the sensor characteristic and the lack of hysteresis. Obtained sensitivity of the sensor prototype was approximately 6,2 mV/mm H2O.

  19. Accuracy of the photogrametric measuring system for large size elements

    M. Grzelka


    Full Text Available The aim of this paper is to present methods of estimating and guidelines for verifying the accuracy of optical photogrammetric measuringsystems, using for measurement of large size elements. Measuring systems applied to measure workpieces of a large size which oftenreach more than 10000mm require use of appropriate standards. Those standards provided by the manufacturer of photogrammetricsystems are certified and are inspected annually. To make sure that these systems work properly there was developed a special standardVDI / VDE 2634, "Optical 3D measuring systems. Imaging systems with point - by - point probing. " According to recommendationsdescribed in this standard research on accuracy of photogrametric measuring system was conducted using K class gauge blocks dedicatedto calibrate and test accuracy of classic CMMs. The paper presents results of research of estimation the actual error of indication for sizemeasurement MPEE for photogrammetric coordinate measuring system TRITOP.

  20. Recent measurements on scintillator-photodetector systems

    Sakai, E.


    The pulse height distributions from eleven kinds of scintillators coupled with a photomultiplier (PMT) and with a silicon photodiode were measured for gamma-ray energies between 14 keV and 1836 keV and compared. The numbers of photoelectrons from the PMT photocathode and those of electron-hole pairs in the photodiode were obtained. The intrinsic pulse height broadening was clearly demonstrated in NaI(T1), CsI(Na), CsI(T1) and CsI(pure) scintillators.

  1. A Raspberry Pi Based Portable Endoscopic 3D Measurement System

    Jochen Schlobohm


    Full Text Available Geometry measurements are very important to monitor a machine part’s health and performance. Optical measurement system have several advantages for the acquisition of a parts geometry: measurement speed, precision, point density and contactless operation. Measuring parts inside of assembled machines is also desirable to keep maintenance cost low. The Raspberry Pi is a small and cost efficient computer that creates new opportunities for compact measurement systems. We have developed a fringe projection system which is capable of measuring in very limited space. A Raspberry Pi 2 is used to generate the projection patterns, acquire the image and reconstruct the geometry. Together with a small LED projector, the measurement system is small and easy to handle. It consists of off-the-shelf products which are nonetheless capable of measuring with an uncertainty of less than 100 μ m .

  2. Study of Electro-Optical Measuring System for Measuring the Swaying of Rocket Launcher and Artillery Systems

    LI Yang; YAN Yu-feng; CAI Li-juan; LIU Zhen-bo


    A scheme is proposed, of that the axis of directional barrel is simulated by a laser beam and an electro-optical axial angle encoder is using to measure the swaying of rocket Muncher or artillery. The measuring principle is stated, and an electro-optical measuring system is designed, including automatic force-applying device, angle-measurement device and photodetecting screen. The measurement accuracy of the system is analyzed. The measuring error of system is less then 17.3"(0.08 mil).

  3. Speckle interferometric system to measure ocular microtremor

    Ryle, James P.; Al-Kalbani, Mohammed; Collins, Niamh; Gopinathan, Unnikrishnan; Boyle, Gerard; Coakley, Davis; Sheridan, John T.


    Ocular microtremor (OMT) is a biological high frequency (up to 150Hz) low amplitude (25-2500nm peak to peak) involuntary motion of the human eye. Clinical OMT investigations to date have used eye-contacting mechanical piezoelectric probes or piezoelectric strain gauges. Before contact can be made, the eye must first be anaesthetized. In some cases, this eyelid spasms occur making it impossible to measure OMT. Using the contact probe method, the eye motion is mechanically loaded. Results from clinical studies with this method to date have given electrical signal amplitudes from the probe proportional to the displacement, but not the exact displacement information. Recent studies suggest a number of clinical applications for OMT, these include monitoring the depth of anesthesia of a patient in surgery, prediction of outcome in coma, diagnosis of brain stem death. In addition to this, in patients with neurological disorders such as Multiple Sclerosis and Parkinson's disease, abnormal OMT frequency content is present. In this paper, we design a compact non-contact phase modulating optical fiber speckle interferometer to measure eye motions. We simulate OMT motion using a calibrated piezoelectric vibration simulator and compare results produced using a contact method with those using our optical non-contact method.

  4. Auto-measuring System of 3- Dimensional Human Body

    李勇; 尚保平; 付小莉; 尚会超


    To realize the automation of fashion industry measuring,designing and manufacturing, the auto-measurement of 3D size of human body is of great importance. The auto measurement system of 3D human body based on Charge Coupled Devices (CCD) and infrared sensors is presented in this paper. The system can measure the bare size of human body that excludes the effect of clothing quickly and accurately.

  5. A flexible microprocessor system for the measurement of cell size.


    A flexible system for the measurement of length and area is described. The system consists of the Reichert Jung MOP-1 area measuring device interfaced with a Commodore PET computer. Its use is illustrated by the planimetric measurement of cross sectional areas in histochemical preparations of normal and diseased muscle. While measurements are being made data can be displayed on the computer screen either in numerical form or as a frequency histogram together with simple statistical analyses. ...

  6. Measuring a System’s Attack Surface


    fold: • In terms of a state machine model of the system, we present formal definitions of attack, attack surface, and attack class. Our definitions are...versions. The rest of this paper is organized as follows. In Section 2, we introduce our state machine model and point out the key differences from...approach in Section 6 and compare it to related work in Section 7. We conclude in Section 8. 2 State Machine Model We use a state machine to model the

  7. Measurement of resilience and its application to enterprise information systems

    Wang, J. W.; Gao, F.; Ip, W. H.


    In this article, we present a measure for resilience in the context of enterprise information systems or service systems in a more general sense. Resilience of the system is a property of the system, which focuses on the recovery ability of the system after a partial damage of the system. Enterprise information systems such as enterprise resource planning, supply chain management, customer relationship management, manufacturing execution system, etc. play a critical role in the daily operation of modern enterprises by timely and sustainable delivery of information. Therefore, resilience is especially important for the enterprise information systems. The proposed measure for resilience is based on the recovery ability of the system, which departs from the existing approaches in literature and presents a unique contribution. An example is given to illustrate how the proposed measure works.

  8. A displacement measurement system based on optical triangulation method

    FU Xian-bin; LIU Bin; ZHANG Yu-cun


    A new displacement measurement system is described in this paper according to the basic principles of traditional laser triangulation method.The range of the traditional measuring method is enlarged by measuring in sections.Three independent CCDs,which are distributed uniformly along the optical axis,are used to achieve subsection measurement.The plane mirror is regarded as a virtual detector.When imaging beam is reflected by the plane mirror,the beam is imaged on the CCD.The designed system is equivalent to add a CCD.The feasibility of the displacement measurement system is verified by the experiment.

  9. [An integrated system of blood pressure measurement with bluetooth communication].

    Wang, Wei; Wang, Jing; Sun, Hongyang; Xu, Zuyang; Chai, Xinyu


    The development of the integrated blood pressure system with bluetooth communication function is introduced. Experimental results show that the system can complete blood pressure measurement and data transmission wireless effectively, which can be used in m-Health in future.

  10. Integrated optical measurement system for fluorescence spectroscopy in microfluidic channels

    Hübner, Jörg; Mogensen, Klaus Bo; Jørgensen, Anders Michael


    A transportable miniaturized fiber-pigtailed measurement system is presented which allows quantitative fluorescence detection in microliquid handling systems. The microliquid handling chips are made in silica on silicon technology and the optical functionality is monolithically integrated...... with the microfluidic channel system. This results in inherent stability and photolithographic alignment precision. Permanently attached optical fibers provide a rugged connection to the light source, detection, and data processing unit, which potentially allows field use of such systems. Fluorescence measurements...

  11. Design techniques for large scale linear measurement systems

    Candy, J.V.


    Techniques to design measurement schemes for systems modeled by large scale linear time invariant systems, i.e., physical systems modeled by a large number (> 5) of ordinary differential equations, are described. The techniques are based on transforming the physical system model to a coordinate system facilitating the design and then transforming back to the original coordinates. An example of a three-stage, four-species, extraction column used in the reprocessing of spent nuclear fuel elements is presented. The basic ideas are briefly discussed in the case of noisy measurements. An example using a plutonium nitrate storage vessel (reprocessing) with measurement uncertainty is also presented.


    Dejan Vidojevic


    Full Text Available This work presents basic elements of availability measurement methodology in complex technical systems according to business and users aspect. Methodology, which is primarily related to IT1 systems, is applied to and presented as a case study of Information system of Tax administration - DIS 2003. To achieve designed objectives of implemented methodology, it is necessary to provide "common" measurement from two different aspects: technical and business. The measurement result is system availability level as well as clear identification of critical components that influence the IT infrastructure stability and assure service continuity provided by the system.

  13. Advanced adhesion and friction measurement system

    Li, Meng; Huang, Wei; Wang, Xiaolei


    An advanced micro-force tester for investigating the micromechanical behavior of various patterned surfaces in dry and wet conditions is presented in this paper. The parallel slice-beam configuration of the tester not only eliminates the large load-dependent slope and tangential displacement at the free end that is found in a single beam system, but also performs a trans-scale deflection with high sensitivity and linearity for force sensing. Meanwhile, the simple structure is characterized by low cost, high efficiency, and ease of fabrication. An integrated nano- and micro-stage comprise the mobile table to produce a large stroke with high resolution, which is specifically required in wet adhesion testing because of the formation of a long liquid bridge. Preliminary experiments of adhesion and friction conducted using PDMS pillars with a plano-convex lens validated the feasibility of this setup.

  14. Competitiveness measurement system in the advertising sector.

    Poveda-Bautista, Rocío; García-Melón, Mónica; Baptista, Doris C


    In this paper a new approach to find indicators that can be used to measure companies' competitiveness and performance in an efficient and reliable way is presented. The aim is to assist managers of companies within a specific industrial sector by providing information about their relative position in the market so as to define better action plans that may improve the company's performance. The approach combines the use of the Analytic Network Process, a multicriteria decision method, with the Balanced Scorecard. It allows the definition of a number of competitiveness indicators based on the performance and setting of the advertising sector. In this way it is possible to obtain a Competitiveness Index that allows a company to know its relative position with respect to other companies in the sector, and establish a ranking of the companies ordered by their competitiveness level. A case study in the advertising industry of Venezuela is provided. Results show that improvement plans for the agencies analyzed should promote creativity, innovation and the use of new technologies, as a particular form of innovation. These factors were considered to be the most relevant indicators in the advertising sector. The participating experts agreed that the methodology is useful and an improvement over current competitiveness assessment methods.

  15. Application research of tune measurement system in Hefei light source

    Sun Bao Gen; Xu Hong Liang; Lu Ping; Wang Jun; Gao Yun Feng; Wang Li; LiuJinYing


    The author introduces the measurement and research of some beam parameters using tune measurement system for Hefei Light Source (HLS), which include the betatron tune, beta function, natural chromaticity, corrected chromaticity, and central frequency. Additionally, it also describes the measurement of the influence of DC clearing electrodes on the betatron tune shift and gives some measurement results. The measurement results are compared with the theoretical values and they are in good agreement

  16. Measuring Isotope Ratios Across the Solar System

    Webster, Chris R.; Mahaffy, Paul R.


    Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biology [1]. For the Allan Hills 84001 meteorite, for example, the (sup 1)(sup 3)C/(sup 1)(sup 2)C ratio identifies it as a Mars (SNC) meteorite; the ??K/??Ar ratio tells us the last time the rock cooled to solid, namely 4 Gya; isotope ratios in (sup 3)He, (sup 2)(sup 1)Ne and (sup 3)?Ar show it was in space (cosmic ray exposure) for 10-20 million years; (sup 1)?C dating that it sat in Antarctica for 13,000 years before discovery; and clumped isotope analysis of (sup 1)?O(sup 1)(sup 3)C(sup 1)?O in its carbonate that it was formed at 18+/-4 ?C in a near-surface aqueous environment [2]. Solar System Formation

  17. Measuring Isotope Ratios Across the Solar System

    Webster, Chris R.; Mahaffy, Paul R.


    Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biology [1]. For the Allan Hills 84001 meteorite, for example, the (sup 1)(sup 3)C/(sup 1)(sup 2)C ratio identifies it as a Mars (SNC) meteorite; the ??K/??Ar ratio tells us the last time the rock cooled to solid, namely 4 Gya; isotope ratios in (sup 3)He, (sup 2)(sup 1)Ne and (sup 3)?Ar show it was in space (cosmic ray exposure) for 10-20 million years; (sup 1)?C dating that it sat in Antarctica for 13,000 years before discovery; and clumped isotope analysis of (sup 1)?O(sup 1)(sup 3)C(sup 1)?O in its carbonate that it was formed at 18+/-4 ?C in a near-surface aqueous environment [2]. Solar System Formation

  18. System design description for surface moisture measurement system (SMMS)

    Vargo, G.F.


    The SMMS has been developed to measure moisture in the top few centimeters of tank waste. The SMMS development was initiated by the preliminary findings of SAR-033, and does not necessarily fulfill any established DQO. After the SAR-033 is released, if no significant changes are made, moisture measurements in the organic waste tanks will rapidly become a DQO. The SMMS was designed to be installed in any 4 inch or larger riser, and to allow maximum adjustability for riser lengths, and is used to deploy a sensor package on the waste surface within a 6 foot radius about the azimuth. The first sensor package will be a neutron probe.

  19. 3D Surface Morphology Measurement and Auto-focusing System

    CHEN Qi; ZANG Huai-pei


    When interference microscope measures the surface rough of the micromechanical device, as soon as the work distance of interference microscope and the depth of field is shortened, the interference images become slur for the measured object if there has small interference after clear focus. The auto-focusing system is introduced into the interference microscope, the system can obtain high definition interference image rapidly,and can improve the measuring velocity and measuring precision. The system is characterized by auto-focusing range of ±150 μm, auto-focusing precision of ±0.3 μm, auto-focusing time of 4~8 s.

  20. Measuring entanglement entropy in a quantum many-body system

    Rispoli, Matthew; Preiss, Philipp; Tai, Eric; Lukin, Alex; Schittko, Robert; Kaufman, Adam; Ma, Ruichao; Islam, Rajibul; Greiner, Markus


    The presence of large-scale entanglement is a defining characteristic of exotic quantum phases of matter. It describes non-local correlations between quantum objects, and is at the heart of quantum information sciences. However, measuring entanglement remains a challenge. This is especially true in systems of interacting delocalized particles, for which a direct experimental measurement of spatial entanglement has been elusive. Here we measure entanglement in such a system of itinerant particles using quantum interference of many-body twins. We demonstrate a novel approach to the measurement of entanglement entropy of any bosonic system, using a quantum gas microscope with tailored potential landscapes. This protocol enables us to directly measure quantum purity, Rényi entanglement entropy, and mutual information. In general, these experiments exemplify a method enabling the measurement and characterization of quantum phase transitions and in particular would be apt for studying systems such as magnetic ordering within the quantum Ising model.

  1. Upgrade of Beam Energy Measurement System at BEPC-II

    Zhang, Jian-Yong; Mo, Xiao-Hu; Guo, Di-Zhou; Wang, Jian-Li; Liu, Bai-Qi; Achasov, M N; Krasnov, A A; Muchnoi, N Yu; Pyata, E E; Mamoshkina, E V; Harris, F A


    The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise instruments are employed to realize the highly accurate measurement of positron/electron beam energy. During five year's running period, in order to meet the requirement of data taking and improve the capacity of measurement itself, the upgradation of system is continued, which involve the component reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the purchase of electric cooling system for high purity germanium detector, and the improvement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and efficient measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III.

  2. A Secure System Architecture for Measuring Instruments in Legal Metrology

    Daniel Peters


    Full Text Available Embedded systems show the tendency of becoming more and more connected. This fact combined with the trend towards the Internet of Things, from which measuring instruments are not immune (e.g., smart meters, lets one assume that security in measuring instruments will inevitably play an important role soon. Additionally, measuring instruments have adopted general-purpose operating systems to offer the user a broader functionality that is not necessarily restricted towards measurement alone. In this paper, a flexible software system architecture is presented that addresses these challenges within the framework of essential requirements laid down in the Measuring Instruments Directive of the European Union. This system architecture tries to eliminate the risks general-purpose operating systems have by wrapping them, together with dedicated applications, in secure sandboxes, while supervising the communication between the essential parts and the outside world.

  3. Research of optical rotation measurement system based on centroid algorithm

    Cao, Junjie; Jia, Hongzhi; Shen, Xinrong; Jiang, Shixin


    An optical rotation measurement system based on digital signal processor, modulated laser, and step motor rotating stage is established. Centroid algorithm featured fast and simple calculation is introduced to process light signals with or without sample to obtain the optical rotating angle through the step difference between two centroids. The system performance is proved experimentally with standard quartz tubes and glucose solutions. After various measurements, the relative error and precision of the system are determined to 0.4% and 0.004°, which demonstrates the reliable repeatability and high accuracy of whole measurement system.

  4. Rating PV Power and Energy: Cell, Module, and System Measurements

    Emery, Keith


    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  5. Modules of systems of measures on polarizable Carnot groups

    Brakalova, M.; Markina, I.; Vasil'ev, A.


    The paper presents a study of Fuglede's p-module of systems of measures in condensers in polarizable Carnot groups. In particular, we calculate the p-module of measures in spherical ring domains, find the extremal measures, and finally, extend a theorem by Rodin to these groups.

  6. A Reference Optical System of Laser Doppler Longitudinal Displacement Measurement

    张存满; 赵洋; 李达成


    In this paper, a new reference optical system is put forward to achieve longitudinal displacement measurement. An optical grating is used for frequency mixing and getting high SNR signals in the measurement. Conditions and methods for getting Doppler beat signals are presented.The experiments indicate that this optical syetem can be used to measure the longitudinal displacement with high accuracy.

  7. Multipartite entanglement in fermionic systems via a geometric measure

    Lari, Behzad; Joag, Pramod S


    We study multipartite entanglement in a system consisting of indistinguishable fermions. Specifically, we have proposed a geometric entanglement measure for N fermions distributed over 2L modes (single particle states). The measure is defined on the 2L qubit space isomorphic to the Fock space for 2L single particle states. This entanglement measure is defined for a given partition of 2L modes containing \\ge 2 subsets. We have shown, using a representative case, that the geometric measure is invariant under local unitaries corresponding to a given partition. We explicitly demonstrate the use of the measure to calculate multipartite entanglement in some correlated electron systems.


    Mykola Mykyychuk


    Full Text Available The authors offer to solve the problem of providing traceability of measurements by increasing metrological autonomy of in-plant measuring systems. The paper shows the expedience of increasing metrological autonomy by creating a "virtual" reference. There are analysed possible variants of implementation of the "virtual" reference, which will provide high metrological stability of measurements at insignificant additional expenses. The authors point out the necessity of creation of universal technical and programmatic means of mutual comparison for the in-plant measuring systems to increase the reliability of measurements in the conditions of metrological autonomy.

  9. Development of Precision Information Measuring System for Ultraviolet Radiation



    Full Text Available Results of studying the neural network method are presented to reduce the amount of calibration points for the multisensor (MS, in particular for the photodiode. This allows transmitting to the MS individual conversion function and provides the high accuracy of measurement. The structure of synthesized information-measuring system and its measuring channel has created for implementing of the proposed approach. A structural scheme is proposed as well for values transmitting the etalon measures to measuring systems. Its used to determine the errors of photodiodes, as those which are produced for customers. This assures the interchangeability of sensors when using the individual conversion function.

  10. A measurement system for thin elastohydrodynamic lubrication films

    WANG Xuefeng; GUO Feng; YANG Peiran


    An elastohydrodynamic lubrication(EHL)film measurement system using multi-beam interferometry is introduced in this paper.The measurement principle and the instrumentation are discussed.A simple and efficient method is suggested to obtain the fringe order of measured points.It is demonstrated that the presented measurement system can provide continuous measurement of lubricating films from nano to micro scales at a nano-level resolution,and can be used to investigate ultra-thin EHL films and tiny variations in EHL films.

  11. Measuring System of Magnetostriction Under AC Excitation Using Optical Methods

    Nakase, Tomoya; Nakano, Masanori; Fujiwara, F.; TAKAHASHI, N


    A measuring system for magnetostriction of silicon steel sheet using optical methods and a single sheet tester has been developed to establish a standard test method for IEC and JIS. Various factors affecting measurement accuracy and reproducibility of the developed system are examined. Two optical instruments, such as a laser Doppler vibrometer and a heterodyne displacement meter, are compared. 3-D characteristics of magnetostriction under ac excitation in the rolling direction are measured ...

  12. A Hand-Eye Vision Measuring System for Articulate Robots

    岁波; 都东; 陈强; 韩翔宇; 王力; 张骅


    To make dynamic measurements for an articulate robot, a hand-eye vision measuring system is built up.This system uses two charge coupled device (CCD) cameras mounted on the end-effector of the robot.System analysis is based on the stereovision theory and line-matching technology, using a computer to evaluate the dynamic performance parameters of an articulate robot from the two images captured by the two cameras.The measuring procedure includes four stages, namely, calibration, sampling, image processing, and calculation.The path accuracy of an articulate industrial robot was measured by this system.The results show that this system is a low-cost, easy to operate, and simple system for the dynamic performance testing of articulate robots.

  13. Observability of Airborne Passive Location System with Phase Difference Measurements

    Deng Xinpu; Wang Qiang; Zhong Danxing


    With a pair of antennas spaced apart, an airborne passive location system measures phase differences of emitting signals. Regarded as cyclic ambiguities, the moduli of the measurements traditionally are resolved by adding more antenna elements. This paper models the cyclic ambiguity as a component of the system state, of which the observability is analyzed and compared to that of the bear- ings-only passive location system. It is shown that the necessary and sufficient observability condition for the bearings-only passive location system is only the necessary observability condition for the passive location system with phase difference measurements, and that when the system state is observable, the cyclic ambiguities can be estimated by accumulating the phase difference measurements, thereby making the observer able to locate the emitter with high-precision.

  14. Practical compensation for nonlinear dynamic thrust measurement system

    Chen Lin


    Full Text Available The real dynamic thrust measurement system usually tends to be nonlinear due to the complex characteristics of the rig, pipes connection, etc. For a real dynamic measuring system, the nonlinearity must be eliminated by some adequate methods. In this paper, a nonlinear model of dynamic thrust measurement system is established by using radial basis function neural network (RBF-NN, where a novel multi-step force generator is designed to stimulate the nonlinearity of the system, and a practical compensation method for the measurement system using left inverse model is proposed. Left inverse model can be considered as a perfect dynamic compensation of the dynamic thrust measurement system, and in practice, it can be approximated by RBF-NN based on least mean square (LMS algorithms. Different weights are set for producing the multi-step force, which is the ideal input signal of the nonlinear dynamic thrust measurement system. The validity of the compensation method depends on the engine’s performance and the tolerance error 0.5%, which is commonly demanded in engineering. Results from simulations and experiments show that the practical compensation using left inverse model based on RBF-NN in dynamic thrust measuring system can yield high tracking accuracy than the conventional methods.

  15. Computer Generated Hologram System for Wavefront Measurement System Calibration

    Olczak, Gene


    Computer Generated Holograms (CGHs) have been used for some time to calibrate interferometers that require nulling optics. A typical scenario is the testing of aspheric surfaces with an interferometer placed near the paraxial center of curvature. Existing CGH technology suffers from a reduced capacity to calibrate middle and high spatial frequencies. The root cause of this shortcoming is as follows: the CGH is not placed at an image conjugate of the asphere due to limitations imposed by the geometry of the test and the allowable size of the CGH. This innovation provides a calibration system where the imaging properties in calibration can be made comparable to the test configuration. Thus, if the test is designed to have good imaging properties, then middle and high spatial frequency errors in the test system can be well calibrated. The improved imaging properties are provided by a rudimentary auxiliary optic as part of the calibration system. The auxiliary optic is simple to characterize and align to the CGH. Use of the auxiliary optic also reduces the size of the CGH required for calibration and the density of the lines required for the CGH. The resulting CGH is less expensive than the existing technology and has reduced write error and alignment error sensitivities. This CGH system is suitable for any kind of calibration using an interferometer when high spatial resolution is required. It is especially well suited for tests that include segmented optical components or large apertures.


    ZHANG Guoyu; SUN Tianxiang; WANG Lingyun; XU Xiping


    The system mathematical model of flexible 3D measuring system is built by theoretical analysis, and the theoretical formula for measuring space point coordinate is also derived.Frog-jumping based coordinate transform method is put forward in order to solve measuring problem for large size parts. The flog-jumping method is discussed, and the coordinate transform mathematical model is method of the space point coordinate compared to original value, and an advanced method is provided. Form the space point coordinate transform formula can derive the calculation measuring method for measuring large size parts.

  17. Exact Pointer Properties for Quantum System Projector Measurements with Application to Weak Measurements and Their Accuracy

    Parks, A D


    Exact pointer states are obtained for projection operator measurements performed upon pre-selected (PS) and upon pre- and post-selected (PPS) quantum systems. These states are used to provide simple exact expressions for both the pointer spatial probability distribution profiles and the mean values of arbitrary pointer observables associated with PS and PPS projection operator measurements that are valid for any strength of the interaction which couples a measurement pointer to the quantum system. These profiles and mean values are compared in order to identify the effects of post-selection upon projector measurement pointers. As a special case, these mean value results are applied to the weak measurement regime - yielding PS and PPS mean value expressions which are valid for any operator (projector or non-projector). Measurement sensitivities which are useful for estimating weak measurement accuracies for PS and PPS systems are also obtained and discussed.



    Based on the development of the non-contact measurement system of free-form surface, NURBS reconstruc-tion of measurement points of freeform surface is effectively realized by modifying the objective function and recursiveprocedure and calculating the optimum number of control points. The reconstruction precision is evaluated through Ja-cobi's transformation method. The feasibility of the measurement system and effectiveness of the reconstruction algo-rithm above are proved by experiment.

  19. Weighted measurement fusion Kalman estimator for multisensor descriptor system

    Dou, Yinfeng; Ran, Chenjian; Gao, Yuan


    For the multisensor linear stochastic descriptor system with correlated measurement noises, the fused measurement can be obtained based on the weighted least square (WLS) method, and the reduced-order state components are obtained applying singular value decomposition method. Then, the multisensor descriptor system is transformed to a fused reduced-order non-descriptor system with correlated noise. And the weighted measurement fusion (WMF) Kalman estimator of this reduced-order subsystem is presented. According to the relationship of the presented non-descriptor system and the original descriptor system, the WMF Kalman estimator and its estimation error variance matrix of the original multisensor descriptor system are presented. The presented WMF Kalman estimator has global optimality, and can avoid computing these cross-variances of the local Kalman estimator, compared with the state fusion method. A simulation example about three-sensors stochastic dynamic input and output systems in economy verifies the effectiveness.

  20. Research and development of the laser tracker measurement system

    Zhang, Z. L.; Zhou, W. H.; Lao, D. B.; Yuan, J.; Dong, D. F. F.; Ji, R. Y. Y.


    The working principle and system design of the laser tracker measurement system are introduced, as well as the key technologies and solutions in the implementation of the system. The design and implementation of the hardware and configuration of the software are mainly researched. The components of the hardware include distance measuring unit, angle measuring unit, tracking and servo control unit and electronic control unit. The distance measuring devices include the relative distance measuring device (IFM) and the absolute distance measuring device (ADM). The main component of the angle measuring device, the precision rotating stage, is mainly comprised of the precision axis and the encoders which are both set in the tracking head. The data processing unit, tracking and control unit and power supply unit are all set in the control box. The software module is comprised of the communication module, calibration and error compensation module, data analysis module, database management module, 3D display module and the man-machine interface module. The prototype of the laser tracker system has been accomplished and experiments have been carried out to verify the proposed strategies of the hardware and software modules. The experiments showed that the IFM distance measuring error is within 0.15mm, the ADM distance measuring error is within 3.5mm and the angle measuring error is within 3〞which demonstrates that the preliminary prototype can realize fundamental measurement tasks.

  1. 32 CFR 32.15 - Metric system of measurement.


    ... comply with requirements concerning the use of the metric system at 32 CFR 22.530. ... 32 National Defense 1 2010-07-01 2010-07-01 false Metric system of measurement. 32.15 Section 32..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 32.15 Metric system of...

  2. Life Cycle Thinking, Measurement and Management for Food System Sustainability.

    Pelletier, Nathan


    Food systems critically contribute to our collective sustainability outcomes. Improving food system sustainability requires life cycle thinking, measurement and management strategies. This article reviews the status quo and future prospects for bringing life cycle approaches to food system sustainability to the fore.

  3. Design of a mobile hydrological data measurement system

    Liu, Yunping; Wang, Tianmiao; Dai, Fenfen


    The current hydrological data acquisition is mainly used in the instrument measurement. Instrument measurement equipment is mainly fixed in a certain water area and the device is easy to be lost. In view of a series of problems, the dynamic measurement system is established by the method of unmanned surface vessel and embedded technology, which can realize any positions measurement of a lake. This method has many advantages, such as mobile convenience, saving money and so on.

  4. Design of High Precision Temperature Measurement System based on Labview

    Weimin Zhu; Jin Liu; Haima Yang; Chaochao Yan


    Using the LabVIEW software platform, a high precision temperature measuring device is designed based on the principle of the thermocouple. The system uses the STM32 MCU as the main control chip, using AD7076 analog digital converter. The converter has 8 channel, synchronous sampling, and bipolar input. Improving the precision of temperature measurement by cold end compensation, fitting and other measures. The test results show that, the device temperature measurement precision can reach ±0.1 ...

  5. A high accuracy broadband measurement system for time resolved complex bioimpedance measurements.

    Kaufmann, S; Malhotra, A; Ardelt, G; Ryschka, M


    Bioimpedance measurements are useful tools in biomedical engineering and life science. Bioimpedance is the electrical impedance of living tissue and can be used in the analysis of various physiological parameters. Bioimpedance is commonly measured by injecting a small well known alternating current via surface electrodes into an object under test and measuring the resultant surface voltages. It is non-invasive, painless and has no known hazards. This work presents a field programmable gate array based high accuracy broadband bioimpedance measurement system for time resolved bioimpedance measurements. The system is able to measure magnitude and phase of complex impedances under test in a frequency range of about 10-500 kHz with excitation currents from 10 µA to 5 mA. The overall measurement uncertainties stay below 1% for the impedance magnitude and below 0.5° for the phase in most measurement ranges. Furthermore, the described system has a sample rate of up to 3840 impedance spectra per second. The performance of the bioimpedance measurement system is demonstrated with a resistor based system calibration and with measurements on biological samples.

  6. Measurement of Supersonic Jet Noise with Optical Wave Microphone System

    Masataka KOSAKA; Kunisato SETO; MD. Tawhidul Islam KHAN; Yoichi NAKAZONO


    An optical wave microphone system is a new technique of sound measurement. This technique has been developed as a new plasma diagnostic technique to measure electron density fluctuations in the nuclear fusion research. Because the sound wave is a pressure or a density fluctuation, it is possible for this technique to measure the sound wave, too. The acoustical characteristics of the optical wave microphone system were examined by using a speaker as a first step. Next, feasibility of this device to measure jet noise was examined. It was found that the optical wave microphone system could measure the jet noise as well as a sound from speaker.Hence the optical wave microphone system can be considered one of the devices equivalent to condenser microphone. Because of these reason, this device is very convenient to scan the acoustic filed through jet flow from the inside to the out side and more preferable for not disturbing the observation field.

  7. Laser measurement and analysis of reposition error in polishing systems

    Liu, Weisen; Wang, Junhua; Xu, Min; He, Xiaoying


    In this paper, robotic reposition error measurement method based on laser interference remote positioning is presented, the geometric error is analyzed in the polishing system based on robot and the mathematical model of the tilt error is presented. Studies show that less than 1 mm error is mainly caused by the tilt error with small incident angle. Marking spot position with interference fringe enhances greatly the error measurement precision, the measurement precision of tilt error can reach 5 um. Measurement results show that reposition error of the polishing system is mainly from the tilt error caused by the motor A, repositioning precision is greatly increased after polishing system improvement. The measurement method has important applications in the actual error measurement with low cost, simple operation.

  8. Advanced Active-Magnetic-Bearing Thrust-Measurement System

    Imlach, Joseph; Kasarda, Mary; Blumber, Eric


    An advanced thrust-measurement system utilizes active magnetic bearings to both (1) levitate a floating frame in all six degrees of freedom and (2) measure the levitation forces between the floating frame and a grounded frame. This system was developed for original use in measuring the thrust exerted by a rocket engine mounted on the floating frame, but can just as well be used in other force-measurement applications. This system offers several advantages over prior thrust-measurement systems based on mechanical support by flexures and/or load cells: The system includes multiple active magnetic bearings for each degree of freedom, so that by selective use of one, some, or all of these bearings, it is possible to test a given article over a wide force range in the same fixture, eliminating the need to transfer the article to different test fixtures to obtain the benefit of full-scale accuracy of different force-measurement devices for different force ranges. Like other active magnetic bearings, the active magnetic bearings of this system include closed-loop control subsystems, through which the stiffness and damping characteristics of the magnetic bearings can be modified electronically. The design of the system minimizes or eliminates cross-axis force-measurement errors. The active magnetic bearings are configured to provide support against movement along all three orthogonal Cartesian axes, and such that the support along a given axis does not produce force along any other axis. Moreover, by eliminating the need for such mechanical connections as flexures used in prior thrust-measurement systems, magnetic levitation of the floating frame eliminates what would otherwise be major sources of cross-axis forces and the associated measurement errors. Overall, relative to prior mechanical-support thrust-measurement systems, this system offers greater versatility for adaptation to a variety of test conditions and requirements. The basic idea of most prior active

  9. Errors Associated With Excess Air Multipoint Measurement Systems

    Ramsunkar Charlene


    Full Text Available Boiler combustion air is generally controlled by the excess air content measured at the boiler economiser outlet using oxygen (O2 analysers. Due to duct geometry and dimensions, areas of high and low O2 concentrations in the flue gas duct occur, which poses a problem in obtaining a representative measurement of O2 in the flue gas stream. Multipoint systems as opposed to single point systems are more favourable to achieve representative readings. However, ash blockages and air leakages influence the accuracy of O2 measurement. The design of multipoint system varies across ESKOMs’ Power Stations. This research was aimed at evaluating the accuracy of the multipoint oxygen measurement system installed at Power Station A and to determine the systematic errors associated with different multipoint systems designs installed at Power Stations' A and B. Using flow simulation software, FloEFDTM and Flownex®, studies were conducted on two types of multipoint system designs This study established that significantly large errors, as high as 50%, were noted between the actual and measured flue gas O2. The design of the multipoint system extraction pipes also introduces significant errors, as high as 23%, in the O2 measured. The results indicated that the sampling errors introduced with Power Station A’s system can be significantly reduced by adopting the sampling pipe design installed at Power Station B.

  10. System security assessment in real-time using synchrophasor measurements

    Jóhannsson, Hjörtur; Wache, Markus


    assessment and sheds light on ongoing research activities that focus on exploiting wide-area synchrophasor measurements for real-time security assessment of sustainable power systems. At last, an mathematical mapping enabling informative visualization of the system state in respect to aperiodic rotor angle...... measures to ensure stable and secure operation of the system are necessary. Time stamped synchrophasor measurements lay the foundation for development of new real-time applications for security and stability assessment. The paper provides overview of existing solutions for synchrophasor based security...

  11. Visual Peoplemeter: A Vision-based Television Audience Measurement System

    SKELIN, A. K.


    Full Text Available Visual peoplemeter is a vision-based measurement system that objectively evaluates the attentive behavior for TV audience rating, thus offering solution to some of drawbacks of current manual logging peoplemeters. In this paper, some limitations of current audience measurement system are reviewed and a novel vision-based system aiming at passive metering of viewers is prototyped. The system uses camera mounted on a television as a sensing modality and applies advanced computer vision algorithms to detect and track a person, and to recognize attentional states. Feasibility of the system is evaluated on a secondary dataset. The results show that the proposed system can analyze viewer's attentive behavior, therefore enabling passive estimates of relevant audience measurement categories.

  12. Developing a lean measurement system to enhance process improvement

    Lewis P.


    Full Text Available A key ingredient to underpin process improvement is a robust, reliable, repeatable measurement system. Process improvement activity needs to be supported by accurate and precise data because effective decision making, within process improvement activity, demands the use of “hard” data. One of the oldest and most established process improvement methods is Deming’s Plan-Do-Check-Act (PDCA cycle which is reliant on the check phase, a measurement activity where data is being gathered and evaluated. Recent expansions of the PDCA such as the Six-Sigma Define-Measure-Analyse-Improve-Control (DMAIC methodology place significant importance upon measurement. The DMAIC cycle incorporates the regimented requirement for the inclusion of measurement system analysis (MSA into the breakthrough strategy. The call for MSA within the DMAIC cycle is to provide the improvement activity with a robust measurement system that will ensure a pertinent level of data during any validation process. The Lean methodology is heavily centred on the removal of the seven Mudas (wastes from a manufacturing process: defects, overproduction, transportation, waiting, inventory, motion and processing. The application of lean, particularly within the manufacturing industry, has led to a perception that measurement is a waste within a manufacturing process because measurement processes identify defective products. The metrologists’ pursuit for measurement excellence could be construed as a hindrance by the “cost down” demands being perpetrated from the same organisation’s lean policy. So what possible benefits does enforcing the regimes of the lean and quality philosophies upon the measurement process have and how does this ultimately enhance the process improvement activity? The key fundamental to embed with any process improvement is the removal of waste. The process improvement techniques embedded within lean and quality concepts are extremely powerful practices in the

  13. Defining pharmaceutical systems strengthening: concepts to enable measurement.

    Hafner, Tamara; Walkowiak, Helena; Lee, David; Aboagye-Nyame, Francis


    Pharmaceutical products are indispensable for improving health outcomes. An extensive body of work on access to and use of medicines has resulted in an assortment of tools measuring various elements of pharmaceutical systems. Until now however, there has been little attempt to conceptualize a pharmaceutical system as an entity and define its strengthening in a way that allows for measuring systems strengthening. The narrow focus of available tools limits their value in ascertaining which interventions result in stronger, more resilient systems. We sought to address this shortcoming by revisiting the current definitions, frameworks and assessment tools related to pharmaceutical systems. We conducted a comprehensive literature review and consulted with select pharmaceutical experts. On the basis of our review, we propose that a pharmaceutical system consists of all structures, people, resources, processes, and their interactions within the broader health system that aim to ensure equitable and timely access to safe, effective, quality pharmaceutical products and related services that promote their appropriate and cost-effective use to improve health outcomes. We further propose that pharmaceutical systems strengthening is the process of identifying and implementing strategies and actions that achieve coordinated and sustainable improvements in the critical components of a pharmaceutical system to make it more responsive and resilient and to enhance its performance for achieving better health outcomes. Finally, we established that, in addition to system performance and resilience, seven components of the pharmaceutical system are critical for measuring pharmaceutical systems strengthening: pharmaceutical products and related services; policy, laws and governance; regulatory systems; innovation, research and development, manufacturing, and trade; financing; human resources; and information. This work adds clarity to the concept of pharmaceutical systems and their

  14. System modeling based measurement error analysis of digital sun sensors

    WEI; M; insong; XING; Fei; WANG; Geng; YOU; Zheng


    Stringent attitude determination accuracy is required for the development of the advanced space technologies and thus the accuracy improvement of digital sun sensors is necessary.In this paper,we presented a proposal for measurement error analysis of a digital sun sensor.A system modeling including three different error sources was built and employed for system error analysis.Numerical simulations were also conducted to study the measurement error introduced by different sources of error.Based on our model and study,the system errors from different error sources are coupled and the system calibration should be elaborately designed to realize a digital sun sensor with extra-high accuracy.

  15. Calibration Techniques for Accurate Measurements by Underwater Camera Systems

    Mark Shortis


    Full Text Available Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  16. Calibration Techniques for Accurate Measurements by Underwater Camera Systems.

    Shortis, Mark


    Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  17. Coherent versus Measurement Feedback: Linear Systems Theory for Quantum Information

    Yamamoto, Naoki


    To control a quantum system via feedback, we generally have two options in choosing a control scheme. One is the coherent feedback, which feeds the output field of the system, through a fully quantum device, back to manipulate the system without involving any measurement process. The other one is measurement-based feedback, which measures the output field and performs a real-time manipulation on the system based on the measurement results. Both schemes have advantages and disadvantages, depending on the system and the control goal; hence, their comparison in several situations is important. This paper considers a general open linear quantum system with the following specific control goals: backaction evasion, generation of a quantum nondemolished variable, and generation of a decoherence-free subsystem, all of which have important roles in quantum information science. Some no-go theorems are proven, clarifying that those goals cannot be achieved by any measurement-based feedback control. On the other hand, it is shown that, for each control goal there exists a coherent feedback controller accomplishing the task. The key idea to obtain all the results is system theoretic characterizations of the above three notions in terms of controllability and observability properties or transfer functions of linear systems, which are consistent with their standard definitions.

  18. Coherent versus Measurement Feedback: Linear Systems Theory for Quantum Information

    Naoki Yamamoto


    Full Text Available To control a quantum system via feedback, we generally have two options in choosing a control scheme. One is the coherent feedback, which feeds the output field of the system, through a fully quantum device, back to manipulate the system without involving any measurement process. The other one is measurement-based feedback, which measures the output field and performs a real-time manipulation on the system based on the measurement results. Both schemes have advantages and disadvantages, depending on the system and the control goal; hence, their comparison in several situations is important. This paper considers a general open linear quantum system with the following specific control goals: backaction evasion, generation of a quantum nondemolished variable, and generation of a decoherence-free subsystem, all of which have important roles in quantum information science. Some no-go theorems are proven, clarifying that those goals cannot be achieved by any measurement-based feedback control. On the other hand, it is shown that, for each control goal there exists a coherent feedback controller accomplishing the task. The key idea to obtain all the results is system theoretic characterizations of the above three notions in terms of controllability and observability properties or transfer functions of linear systems, which are consistent with their standard definitions.


    WANG Yan-shuang; ZHANG Luo-ping; YANG Bo-yuan


    A ball-disc traction test rig is improved through the development of a lubricant traction measurement system,consisting of a resonance force sensitive quartz sensor,a circuit of the sensor and a rigid bracket jointed by a frictionless hinge.The traction coefficients of a kind of domestic lubricating oil were measured at various normal loads,rolling velocities,lubricant inlet temperatures and slide-to-roll ratios on a ball-disc traction test rig equipped with this traction measurement system.The results show that the traction test curve is smooth and the data enjoy a good accuracy,which indicates that the design of the lubricant traction measurement system is reasonable and the precision of the system is high,especially,at high temperature,high rolling speed and small slide-to-roll ratio.

  20. Absolute viscosity measured using instrumented parallel plate system

    Broyles, H. H.


    An automatic system measures the true average shear viscosity of liquids and viscoelastic materials, using the parallel plate method and automatically displays the results on a graphic record. This eliminates apparatus setup and extensive calculations.

  1. Method for effective dead time measurement in counting systems

    Vinagre, F.L.R. E-mail:; Conde, C.A.N


    The counting losses introduced by the dead time of a counting system are a limiting factor in counting measurements. The purpose of this work is to report an efficient method for the measurement of the effective dead time of a counting system and to characterize its dead time behavior, providing a way to investigate each experimental situation. The method, which we designate as Delayed and Mixed Pulses method, is based on the artificial piling-up of detector pulses with electronic pulses delayed by a specific time interval. It is applicable to the measurement of the effective dead time of a counting system, including both pile-up effects and the dead time characteristics of the elements of the counting chain. With counting systems relying on gaseous radiation detectors, we achieved a standard uncertainty of about 5-10% in the dead times measured.

  2. Oceanographic measurements from the Texas Automated Buoy System (TABS)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Texas Automated Buoy System contains daily oceanographic measurements from seven buoys off the Texas coast from Brownsville to Sabine. The Texas General Land...

  3. System design of welding dynamic displacement measurement using laser ESPI


    Based on the advantages of electronic speckle pattern interferometry(ESPI), such as non-contact, high precision, strong parasitic light resistance, and full-field measurement, a system for measuring welding dynamic displacement fields using ESPI was designed. The system consists of a 70mW He-Ne laser source, an optical path system, a computer-assisted frame grabber and a processing system. By measuring dynamic displacement fields on one LY2 aluminum alloy plate during an argon arc point welding, it can be proved that using ESPI to measure welding dynamic displacement fields is fully feasible, and this method can offer a solid experimental base for the structure mechanics.

  4. Design of multi-spectrum BRDF measurement system

    Zhongyi Zhao; Chao Qi; Jingmin Dai


    A multi-spectrum bidirectional reflectance distribution function (BRDF) measurement system was developed with the adoption of single reference standard measurement method. An arm-adjustable corner device was designed for the BRDF system. Changing the distance to the sample by moving the detector arm made the device applicable to different wavelengths. The system could be used for the spectrum range from visible light (0.6328 μm) to mid-far infrared (10.6 μm), the facular size between 0.8-3 cm.The rotating limit of detector arm was ±180°, the rotation range of sample holding table was 360°, and the angle resolution was 0.036°. A silicon carbide sample was measured using this system with reflectance zenith from -55° to +55°. According to the error analysis, the measurement uncertainty of this device was about 6.42%.

  5. Attitude angular measurement system based on MEMS accelerometer

    Luo, Lei


    For the purpose of monitoring the attitude of aircraft, an angular measurement system using a MEMS heat convection accelerometer is presented in this study. A double layers conditioning circuit that center around the single chip processor is designed and built. Professional display software with the RS232 standard is used to communicate between the sensor and the computer. Calibration experiments were carried out to characterize the measuring system with the range of - 90°to +90°. The curves keep good linearity with the practical angle. The maximum deviation occurs at the 90°where the value is 2.8°.The maximum error is 1.6% and the repeatability is measured to be 2.1%. Experiments proved that the developed measurement system is capable of measuring attitude angle.

  6. Calibration procedure of measuring system for vehicle wheel load estimation

    Kluziewicz, M.; Maniowski, M.


    The calibration procedure of wheel load measuring system is presented. Designed method allows estimation of selected wheel load components while the vehicle is in motion. Mentioned system is developed to determine friction forces between tire and road surface, basing on measured internal reaction forces in wheel suspension mechanism. Three strain gauge bridges and three-component piezoelectric load cell are responsible for internal force measurement in suspension components, two wire sensors are measuring displacements. External load is calculated via kinematic model of suspension mechanism implemented in Matlab environment. In the described calibration procedure, internal reactions are measured on a test stand while the system is loaded by a force of known direction and value.

  7. Uncertainty Measures in Ordered Information System Based on Approximation Operators

    Bingjiao Fan


    Full Text Available This paper focuses on constructing uncertainty measures by the pure rough set approach in ordered information system. Four types of definitions of lower and upper approximations and corresponding uncertainty measurement concepts including accuracy, roughness, approximation quality, approximation accuracy, dependency degree, and importance degree are investigated. Theoretical analysis indicates that all the four types can be used to evaluate the uncertainty in ordered information system, especially that we find that the essence of the first type and the third type is the same. To interpret and help understand the approach, experiments about real-life data sets have been conducted to test the four types of uncertainty measures. From the results obtained, it can be shown that these uncertainty measures can surely measure the uncertainty in ordered information system.

  8. Design of High Precision Temperature Measurement System based on Labview

    Weimin Zhu


    Full Text Available Using the LabVIEW software platform, a high precision temperature measuring device is designed based on the principle of the thermocouple. The system uses the STM32 MCU as the main control chip, using AD7076 analog digital converter. The converter has 8 channel, synchronous sampling, and bipolar input. Improving the precision of temperature measurement by cold end compensation, fitting and other measures. The test results show that, the device temperature measurement precision can reach ±0.1 °C, has the advantages of small size, high precision, and reliable performance, this high precision temperature measurement can be widely used in industrial production.

  9. Quadratic measurement and conditional state preparation in an optomechanical system

    A. Brawley, George; Vanner, Michael A.; Bowen, Warwick P.;


    We experimentally demonstrate, for the first time, quadratic measurement of mechanical motion in an optomechanical system. We use this nonlinear easurement to conditionally prepare classical non-Gaussian states of motion of a micro-mechanical oscillator.......We experimentally demonstrate, for the first time, quadratic measurement of mechanical motion in an optomechanical system. We use this nonlinear easurement to conditionally prepare classical non-Gaussian states of motion of a micro-mechanical oscillator....

  10. A System for Measurement of Convection Aboard Space Station

    Bogatyrev, Gennady P.; Gorbunov, Aleksei V; Putin, Gennady F.; Ivanov, Alexander I.; Nikitin, Sergei A.; Polezhaev, Vadim I.


    A simple device for direct measurement of buoyancy driven fluid flows in a low-gravity environment is proposed. A system connecting spacecraft accelerometers data and results of thermal convection in enclosure measurements and numerical simulations is developed. This system will permit also to evaluate the low frequency microacceleration component. The goal of the paper is to present objectives and current results of ground-based experimental and numerical modeling of this convection detector.

  11. Similarity measure application to fault detection of flight system

    KIM J H; LEE S H; WANG Hong-mei


    Fault detection technique is introduced with similarity measure. The characteristics of conventional similarity measure based on fuzzy number are discussed. With the help of distance measure, similarity measure is constructed explicitly. The designed distance-based similarity measure is applicable to general fuzzy membership functions including non-convex fuzzy membership function, whereas fuzzy number-based similarity measure has limitation to calculate the similarity of general fuzzy membership functions. The applicability of the proposed similarity measure to general fuzzy membership structures is proven by identifying the definition. To decide fault detection of flight system, the experimental data (pitching moment coefficients and lift coefficients) are transformed into fuzzy membership functions. Distance-based similarity measure is applied to the obtained fuzzy membership functions, and similarity computation and analysis are obtained with the fault and normal operation coefficients.

  12. Objective test and performance measurement of automotive crash warning systems

    Szabo, S.; Norcross, R. J.; Falco, J. A.


    The National Institute of Standards and Technology (NIST), under an interagency agreement with the United States Department of Transportation (DOT), is supporting development of objective test and measurement procedures for vehicle-based warning systems intended to warn an inattentive driver of imminent rear-end, road-departure and lane-change crash scenarios. The work includes development of track and on-road test procedures, and development of an independent measurement system, which together provide data for evaluating warning system performance. This paper will provide an overview of DOT's Integrated Vehicle-Based Safety System (IVBSS) program along with a review of the approach for objectively testing and measuring warning system performance.

  13. Notes on nonlocal projective measurements in relativistic systems

    Lin, Shih-Yuin


    In quantum mechanical bipartite systems, naive extensions of von Neumann's projective measurement to nonlocal variables can produce superluminal signals and thus violate causality. We analyze the projective quantum nondemolition state-verification in a two-spin system and see how the projection introduces nonlocality without entanglement. For the ideal measurements of "R-nonlocal" variables, we argue that causality violation can be resolved by introducing further restrictions on the post-measurement states, which makes the measurement "Q-nonlocal". After we generalize these ideas to quantum mechanical harmonic oscillators, we look into the projective measurements of the particle number of a single mode or a wave-packet of a relativistic quantum field in Minkowski space. It turns out that the causality-violating terms in the expectation values of the local operators, generated either by the ideal measurement of the "R-nonlocal" variable or the quantum nondemolition verification of a Fock state, are all suppres...

  14. Hierarchical, Three-Dimensional Measurement System for Crime Scene Scanning.

    Marcin, Adamczyk; Maciej, Sieniło; Robert, Sitnik; Adam, Woźniak


    We present a new generation of three-dimensional (3D) measuring systems, developed for the process of crime scene documentation. This measuring system facilitates the preparation of more insightful, complete, and objective documentation for crime scenes. Our system reflects the actual requirements for hierarchical documentation, and it consists of three independent 3D scanners: a laser scanner for overall measurements, a situational structured light scanner for more minute measurements, and a detailed structured light scanner for the most detailed parts of tscene. Each scanner has its own spatial resolution, of 2.0, 0.3, and 0.05 mm, respectively. The results of interviews we have conducted with technicians indicate that our developed 3D measuring system has significant potential to become a useful tool for forensic technicians. To ensure the maximum compatibility of our measuring system with the standards that regulate the documentation process, we have also performed a metrological validation and designated the maximum permissible length measurement error EMPE for each structured light scanner. In this study, we present additional results regarding documentation processes conducted during crime scene inspections and a training session.

  15. Space camera optical axis pointing precision measurement system

    Chen, Gang; Meng, Fanbo; Yang, Zijun; Guo, Yubo; Ye, Dong


    In order to realize the space camera which on satellite optical axis pointing precision measurement, a monocular vision measurement system based on object-image conjugate is established. In this system the algorithms such as object-image conjugate vision models and point by point calibration method are applied and have been verified. First, the space camera axis controller projects a laser beam to the standard screen for simulating the space camera's optical axis. The laser beam form a target point and has been captured by monocular vision camera. Then the two-dimensional coordinates of the target points on the screen are calculated by a new vision measurement model which based on a looking-up and matching table, the table has been generated by object-image conjugate algorithm through point by point calibration. Finally, compare the calculation of coordinates offered by measurement system with the theory of coordinate offered by optical axis controller, the optical axis pointing precision can be evaluated. Experimental results indicate that the absolute precision of measurement system up to 0.15mm in 2m×2m FOV. This measurement system overcome the nonlinear distortion near the edge of the FOV and can meet the requirement of space camera's optical axis high precision measurement and evaluation.

  16. Study on portable optical 3D coordinate measuring system

    Ren, Tongqun; Zhu, Jigui; Guo, Yinbiao


    A portable optical 3D coordinate measuring system based on digital Close Range Photogrammetry (CRP) technology and binocular stereo vision theory is researched. Three ultra-red LED with high stability is set on a hand-hold target to provide measuring feature and establish target coordinate system. Ray intersection based field directional calibrating is done for the intersectant binocular measurement system composed of two cameras by a reference ruler. The hand-hold target controlled by Bluetooth wireless communication is free moved to implement contact measurement. The position of ceramic contact ball is pre-calibrated accurately. The coordinates of target feature points are obtained by binocular stereo vision model from the stereo images pair taken by cameras. Combining radius compensation for contact ball and residual error correction, object point can be resolved by transfer of axes using target coordinate system as intermediary. This system is suitable for on-field large-scale measurement because of its excellent portability, high precision, wide measuring volume, great adaptability and satisfying automatization. It is tested that the measuring precision is near to +/-0.1mm/m.

  17. System for deflection measurements of floating dry docks

    Gorbachev, Alexey A.; Pantyushin, Anton V.; Serikova, Mariya G.; Korotaev, Valery V.; Timofeev, Aleksandr N.


    In this paper we introduce a system for deflection measurement of floating dry docks. The system contains two measurement channels observing opposite directions of the dock. It also includes set of reference marks, an industrial computer and a display. Each channel contains CMOS camera with long focal-length lens. Reference marks are implemented as IR LED arrays with 940 nm working wavelength for better performance within bad weather conditions (e.g. fog, rain, high humidity etc.). In the paper we demonstrate results of an analysis of different optical schemes for coupling the oppositely directed channels of the measurement unit and show that the scheme with two image sensors with separated lenses is an optimal option, because it allows usage of nonequidistant location of reference marks and demonstrates the least value of parasitic shift caused by rotations of the measuring unit. The developed system was tested both on specially-designed setup and in real infrastructure of a floating dry dock. The conducted tests proved that a measuring error of the system is smaller than +/- 1.5 mm within the measurement range of +/- 150 mm when deflection of 100 m dock is measured. Obtained results showed that the system demonstrates an ability to work in a harsh environment including poor weather conditions.

  18. System for Measuring Elevator Guide Rail Quality and Its Calibration


    A system for measuring the quality parameters of elevator guide rails is developed. The quality parameters the system can measure include straightness, flatness, squareness, width and height of the rail. The system consists of six parts:main guideway, auxiliary guideway, reference rail, saddle, control casing and measured rail. The guide rail to be measured is mounted on a bed.The straightness errors of surfaces are checked by five linear displacement sensors mounted on the saddle. The deviation of readings from the sensor, which is in contact with top guiding surface,gives the straightness error of the surface and height of the rail. The other four sensors are used to measure side guiding surfaces respectively and give other parameters including flatness on the surfaces, squareness, width and height of the rail. A novel calibration method is also developed to calibrate the straightness motion error of the system in horizontal and vertical directions. The deflection deformation of the measured rail is fitted by using a fourth-order polynomial. Experimental results show that the uncertainty of the system on the side surfaces after compensating the straightness motion error is less than 0.01 mm, and the uncertainty of the system on the top surface after compensating the straightness motion error and the deflection deformation of the rail is less than 0.03 mm.

  19. A measure of internal synergy of the collective system

    Novikov V.A.


    Full Text Available Background: The authors examine the methodology of HRM personnel management based on ratings. Proposed to represent a collective system that uses a matrix of pair relations as a system of linear differential equations. The condition of auto generation of an autonomous system can be determined by the application of the Laplace transformation to the system. This condition mainly depends on the main eigenvalue of dating relationships matrix. Assuming the oscillation frequency is straightly proportional to the system's synergy rating, a special algorithm of comparative evaluation of several collective systems was suggested. Methods: The calculation of the rating of internal synergies is based on the representation of the collective system as a system of linear differential equations, the coefficients of which are obtained by questionnaire survey of all members of the team. Internal representation of the system's synergism as a stimulation of an autonomous system allows using the eigenvector of the system as a measure of internal synergies. Results: The result of this method is the rating of members of interacting collective systems in terms of their contribution to the self-organization sharing behavior.  Conclusions:  Using a matrix of pair relations allows without direct programming and only using MathCad determines the measure of internal synergy of a collective system.  

  20. Consensus of Multiagent Systems with Sampled Information and Noisy Measurements

    Zhao-Jun Tang


    Full Text Available We consider consensus problems of first-order multiagent systems with sampled information and noisy measurements. A distributed stochastic approximation type algorithm is employed to attenuate the measurement noises. We provide conditions under which almost sure strong consensus is guaranteed for fixed and switching directed network topologies. Simulation results are provided to illustrate the theoretical results.

  1. Measurement System for Playout Delay of TV Signals

    Kooij, W.J.; Stokking, H.M.; Brandenburg, R. van; Boer, P.T. de


    TV signals are carried towards end-users using different (broadcast) technologies and by different providers. This is causing differences in the playout timing of the TV signal at different locations and devices. Authors have developed a measurement system for measuring the relative playout delay of

  2. Squeezing-enhanced measurement sensitivity in a cavity optomechanical system

    Kerdoncuff, Hugo; Hoff, Ulrich Busk; Harris, Glen I.;


    We determine the theoretical limits to squeezing-enhanced measurement sensitivity of mechanical motion in a cavity optomechanical system. The motion of a mechanical resonator is transduced onto quadrature fluctuations of a cavity optical field and a measurement is performed on the optical field e...

  3. Measurement System for Playout Delay of TV Signals

    Kooij, W.J.; Stokking, H.M.; Brandenburg, R. van; Boer, P.T. de


    TV signals are carried towards end-users using different (broadcast) technologies and by different providers. This is causing differences in the playout timing of the TV signal at different locations and devices. Authors have developed a measurement system for measuring the relative playout delay of

  4. 2 CFR 215.15 - Metric system of measurement.


    ... Programs” (56 FR 35801, 3 CFR, 1991 Comp., p. 343). ... 2 Grants and Agreements 1 2010-01-01 2010-01-01 false Metric system of measurement. 215.15 Section... measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C....

  5. 3D measurement system based on computer-generated gratings

    Zhu, Yongjian; Pan, Weiqing; Luo, Yanliang


    A new kind of 3D measurement system has been developed to achieve the 3D profile of complex object. The principle of measurement system is based on the triangular measurement of digital fringe projection, and the fringes are fully generated from computer. Thus the computer-generated four fringes form the data source of phase-shifting 3D profilometry. The hardware of system includes the computer, video camera, projector, image grabber, and VGA board with two ports (one port links to the screen, another to the projector). The software of system consists of grating projection module, image grabbing module, phase reconstructing module and 3D display module. A software-based synchronizing method between grating projection and image capture is proposed. As for the nonlinear error of captured fringes, a compensating method is introduced based on the pixel-to-pixel gray correction. At the same time, a least square phase unwrapping is used to solve the problem of phase reconstruction by using the combination of Log Modulation Amplitude and Phase Derivative Variance (LMAPDV) as weight. The system adopts an algorithm from Matlab Tool Box for camera calibration. The 3D measurement system has an accuracy of 0.05mm. The execution time of system is 3~5s for one-time measurement.

  6. Enhanced data consistency of a portable gait measurement system

    Lin, Hsien-I.; Chiang, Y. P.


    A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.

  7. Review of Prior U.S. Attribute Measurement Systems

    White, G K


    Attribute Measurement Systems have been developed and demonstrated several times in the United States over the last decade or so; under the Trilateral Initiative (1996-2002), FMTTD (Fissile Material Transparency Technology Demonstration, 2000), and NG-AMS (Next Generation Attribute Measurement System, 2005-2008). Each Attribute Measurement System has contributed to the growing body of knowledge regarding the use of such systems in warhead dismantlement and other Arms Control scenarios. The Trilateral Initiative, besides developing prototype hardware/software, introduced the topic to the international community. The 'trilateral' parties included the United States, the Russian Federation, and the International Atomic Energy Agency (IAEA). With the participation of a Russian delegation, the FMTTD demonstrated that measurements behind an information barrier are feasible while meeting host party security requirements. The NG-AMS system explored the consequences of maximizing the use of Commercial off the Shelf (COTS) equipment, which made construction easier, but authentication harder. The 3rd Generation Attribute Measurement System (3G-AMS) will further the scope of previous systems by including additional attributes and more rigor in authentication.

  8. Procurement performance measurement system in the health care industry.

    Kumar, Arun; Ozdamar, Linet; Ng, Chai Peng


    The rising operating cost of providing healthcare is of concern to health care providers. As such, measurement of procurement performance will enable competitive advantage and provide a framework for continuous improvement. The objective of this paper is to develop a procurement performance measurement system. The paper reviews the existing literature in procurement performance measurement to identify the key areas of purchasing performance. By studying the three components in the supply chain collectively with the resources, procedures and output, a model is been developed. Additionally, a balanced scorecard is proposed by establishing a set of generic measures and six perspectives. A case study conducted at the Singapore Hospital applies the conceptual model to describe the purchasing department and the activities within and outside the department. The results indicate that the material management department has already made a good start in measuring the procurement process through the implementation of the balanced scorecard. There are many data that are collected but not properly collated and utilized. Areas lacking measurement include cycle time of delivery, order processing time, effectiveness, efficiency and reliability. Though a lot of hard work was involved, the advantages of establishing a measurement system outweigh the costs and efforts involved in its implementation. Results of balanced scorecard measurements provide decision-makers with critical information on efficiency and effectiveness of the purchasing department's work. The measurement model developed could be used for any hospital procurement system.

  9. 24 CFR 84.15 - Metric system of measurement.


    ... business-related activities. Metric implementation may take longer where the use of the system is initially... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Metric system of measurement. 84.15 Section 84.15 Housing and Urban Development Office of the Secretary, Department of Housing and Urban...

  10. 10 CFR 600.115 - Metric system of measurement.


    ... 10 Energy 4 2010-01-01 2010-01-01 false Metric system of measurement. 600.115 Section 600.115 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL ASSISTANCE RULES Uniform..., Hospitals, and Other Nonprofit Organizations Pre-Award Requirements § 600.115 Metric system of...

  11. A robotic vision system to measure tree traits

    The autonomous measurement of tree traits, such as branching structure, branch diameters, branch lengths, and branch angles, is required for tasks such as robotic pruning of trees as well as structural phenotyping. We propose a robotic vision system called the Robotic System for Tree Shape Estimati...

  12. Evaluation of a load measurement system for cotton harvesters

    The objective of this work is to develop and characterize the performance of a system used onboard a cotton harvester for obtaining seed cotton weight data. This system can be used to measure seed cotton weight on a load by load basis, thereby enhancing the ability for a producer to conduct on-farm ...

  13. A comprehensive bibliography on effectiveness measurement of manufacturing systems

    Sandeep Grover


    Full Text Available Globalization has put fierce competition for manufacturing managers in terms of flexibility, smaller lead times, competitive costs, etc. To attain these capabilities, manufacturing managers are taking heedless decisions for investing in advanced manufacturing technologies, without measuring their actual effectiveness for their organisations. There is a need to measure the effectiveness of manufacturing systems to make better future policies and investment planning. This paper provides a comprehensive bibliography on the techniques and their rationale in the effectiveness measurement of advanced manufacturing systems. The paper cites 265 articles from a variety of published sources. The list contains published research mainly from 1990 to 2012 and a selected published work prior to 1990.

  14. An Introduction to CUSUM Charts for COntrolling Measurement Systems

    Madsen, Henrik


    This paper gives an introduction to the CUSUM technique for quality assurance of measuring sytems. A seperate paper (Madsen 1998) gives a more detailed description of the mathematics behind the CUSUM technique. Also a brief description of some of the international standards which could be used...... for quality assurance of a measuring system is provided.The CUSUM technique is weel suited for detection of even rather small (systematical) errors of a measuring system, and the technique gives also an estimate of the time point were the error occurred....

  15. An All Fiber White Light Interferometric Absolute Temperature Measurement System

    Jeonggon Harrison Kim


    Full Text Available Recently the author of this article proposed a new signal processing algorithm for an all fiber white light interferometer. In this article, an all fiber white light interferometric absolute temperature measurement system is presented using the previously proposed signal processing algorithm. Stability and absolute temperature measurement were demonstrated. These two tests demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe and 0.0005 fringe, respectively. A hysteresis test from 373K to 873K was also presented. Finally, robustness of the sensor system towards laser diode temperature drift, AFMZI temperature drift and PZT non-linearity was demonstrated.

  16. The new magnetic measurement system at the Advanced Photon Source.

    Eidelman, Y.; Deriy, B.; Makarov, O.; Vasserman, I.


    A new system for precise measurements of the field integrals and multipole components of the APS magnetic insertion devices is described. A stretched coil is used to measure magnetic field characteristics. The hardware includes a number of servomotors to move (translate or rotate) the coil and a fast data acquisition board to measure the coil signal. A PC under Linux is used as a control workstation. The user interface is written as a Tcl/tk script; the hardware is accessed from the script through a shared C-library. A description of the hardware system and the control program is given.

  17. The new Magnetic Measurement System at the Advanced Photon Source

    Eidelman, Y; Makarov, O P; Vasserman, I B; Eidelman, Yu.


    A new system for precise measurements of the field integrals and multipole components of the APS magnetic insertion devices is described. A stretched coil is used to measure magnetic field characteristics. The hardware includes a number of servomotors to move (translate or rotate) the coil and a fast data acquisition board to measure the coil signal. A PC under Linux is used as a control workstation. The user interface is written as a Tcl/tk script. The hardware is accessed from the script through a shared C-library. A description of the hardware system and the control program is given.

  18. Working principles of the energy measurement system at BEPC Ⅱ


    The proposed beam energy measurement system at BEPCⅡ is composed of three parts:the laser source and optics system,the laser-electron interaction system and the HPGe detector system.The working principles of each system are expounded together with the calculation for preliminary design.The normalizations of laser and electron beams are put forth and used for the evaluation of intensity of the backscattering photon.The simulation of HPGe detector is also performed for understanding the working properties.

  19. A time-dependent measuring system for welding deformation

    蔡志鹏; 赵海燕; 鹿安理; 史清宇; 施光凯


    In this paper the establishment and application of a time-dependent measuring system for welding deformation are presented which is established with high quality sensors shielded from strong welding interference. By using this system, vertical and horizontal displacements of the high temperature area are surveyed at the same time. And this system is also used for monitoring and controlling the deformation of real welded structures.



    Developing CNC measuring method on the base of coordinate machine can make the best of the hardware resource of CNC system and realize the integration of CAD/CAM/CAT. Based on the evenly spaced parallel planes scanning, a new adaptive digitizing approach for freeform surface namely arc length extrapolation is put forward. By this way, the digitizing approach can be added to the CNC system, while the system's hardware and software are not changed.

  1. Personal Computer System for Automatic Coronary Venous Flow Measurement

    Dew, Robert B.


    We developed an automated system based on an IBM PC/XT Personal computer to measure coronary venous blood flow during cardiac catheterization. Flow is determined by a thermodilution technique in which a cold saline solution is infused through a catheter into the coronary venous system. Regional temperature fluctuations sensed by the catheter are used to determine great cardiac vein and coronary sinus blood flow. The computer system replaces manual methods of acquiring and analyzing temperatur...

  2. Performance of the beam phase measurement system for LEDA

    Power, J. F.; Barr, D.; Gilpatrick, J. D.; Kasemir, K.; Shurter, R. B.; Stettler, M.


    The Low Energy Demonstration Accelerator (LEDA) facility diagnostics include beam phase measurements [1]. Beam signals at 350 MHz from capacitive probes are down-converted to 2 MHz for processing. The phase measurement process includes amplitude leveling, digital sampling of the I and Q vectors, DSP filtering and calibration, and serving of the data to the network. All hardware is fielded in the VXI format and controlled with a PC. Running under Windows NT, a LabVIEW® program controls the operation of the system and serves the data, via channel access, to the EPICS control system. The design and operational performance to date of the system is described.

  3. Foldable micro coils for a transponder system measuring intraocular pressure

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)


    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  4. Comparison of Laboratory Measurements for IR Imaging System Performance

    LI Sheng-cai; XU Zong-chang; XIAO Shun-wang


    Sensitivity and human performance are two important parameters for IR imaging system. Noise equivalent temperature difference (NETD) and minimum resolvable temperature difference (MRTD) can describe sensitivity and human performance of IR imaging system. So a lot of engineers apply themselves to studying the methods to measure NETD and MRTD for IR imaging system. The classical laboratory measurement methodologies for NETD and MRTD are introduced. And, two new approaches to three-dimensional (3-D) noise and MRTD/MRC are also portrayed, which can overcome some of the disadvantages existed in classical testing of NETD and MRTD. With the help of the new laboratory measurements, the disadvantages of the classical methods to measure NETD and MRTD can be solved.

  5. Optical Measurement System for Motion Characterization of Surface Mount Technology

    LI Song; AN Bing; ZHANG Tong-jun; XIE Yong-jun


    Advanced testing methods for the dynamics of mechanical microdevices are necessary to develop reliable,marketable microelectromechanical systems. A system for measuring the nanometer motions of microscopic structures has been demonstrated. Stop-action images of a target have been obtained with computer microvision,microscopic interferometry,and stroboscopic illuminator. It can be developed for measuring the in-plane-rigid-body motions,surface shapes,out-of-plane motions and deformations of microstructures. A new algorithm of sub-pixel step length correlation template matching is proposed to extract the in-plane displacement from vision images. Hariharan five-step phase-shift interferometry algorithm and unwrapping algorithms are adopted to measure the out-of-plane motions. It is demonstrated that the system can measure the motions of solder wetting in surface mount technology(SMT).

  6. Measuring entanglement entropy in a quantum many-body system.

    Islam, Rajibul; Ma, Ruichao; Preiss, Philipp M; Tai, M Eric; Lukin, Alexander; Rispoli, Matthew; Greiner, Markus


    Entanglement is one of the most intriguing features of quantum mechanics. It describes non-local correlations between quantum objects, and is at the heart of quantum information sciences. Entanglement is now being studied in diverse fields ranging from condensed matter to quantum gravity. However, measuring entanglement remains a challenge. This is especially so in systems of interacting delocalized particles, for which a direct experimental measurement of spatial entanglement has been elusive. Here, we measure entanglement in such a system of itinerant particles using quantum interference of many-body twins. Making use of our single-site-resolved control of ultracold bosonic atoms in optical lattices, we prepare two identical copies of a many-body state and interfere them. This enables us to directly measure quantum purity, Rényi entanglement entropy, and mutual information. These experiments pave the way for using entanglement to characterize quantum phases and dynamics of strongly correlated many-body systems.

  7. The AD and ELENA orbit, trajectory and intensity measurement systems

    Marco-Hernández, R.; Alves, D.; Angoletta, M. E.; Marqversen, O.; Molendijk, J.; Oponowicz, E.; Ruffieux, R.; Sánchez-Quesada, J.; SØby, L.


    This paper describes the new Antiproton Decelerator (AD) orbit measurement system and the Extra Low ENergy Antiproton ring (ELENA) orbit, trajectory and intensity measurement system. The AD machine at European Organization for Nuclear Research (CERN) is presently being used to decelerate antiprotons from 3.57 GeV/c to 100 MeV/c for matter vs anti-matter comparative studies. The ELENA machine, presently under commissioning, has been designed to provide an extra deceleration stage down to 13.7 MeV/c. The AD orbit system is based on 32 horizontal and 27 vertical electrostatic Beam Position Monitor (BPM) fitted with existing low noise front-end amplifiers while the ELENA system consists of 24 \\gls{BPM}s equipped with new low-noise head amplifiers. In both systems the front-end amplifiers generate a difference (delta) and a sum (sigma) signal which are sent to the digital acquisition system, placed tens of meters away from the AD or ELENA rings, where they are digitized and further processed. The beam position is calculated by dividing the difference signal by the sum signal either using directly the raw digitized data for measuring the turn-by-turn trajectory in the ELENA system or after down-mixing the signals to baseband for the orbit measurement in both machines. The digitized sigma signal will be used in the ELENA system to calculate the bunched beam intensity and the Schottky parameters with coasting beam after passing through different signal processing chain. The digital acquisition arrangement for both systems is based on the same hardware, also used in the ELENA Low Level Radio Frequency (LLRF) system, which follows the VME Switched Serial (VXS) enhancement of the Versa Module Eurocard 64x extension (VME64x) standard and includes VITA 57 standard Field Programmable Gate Array Mezzanine Card (FMC). The digital acquisition Field Programmable Gate Array (FPGA) and Digital Signal Processor (DSP) firmware shares many common functionalities with the LLRF system but

  8. Imaging Systems for Size Measurements of Debrisat Fragments

    Shiotani, B.; Scruggs, T.; Toledo, R.; Fitz-Coy, N.; Liou, J. C.; Sorge, M.; Huynh, T.; Opiela, J.; Krisko, P.; Cowardin, H.


    The overall objective of the DebriSat project is to provide data to update existing standard spacecraft breakup models. One of the key sets of parameters used in these models is the physical dimensions of the fragments (i.e., length, average-cross sectional area, and volume). For the DebriSat project, only fragments with at least one dimension greater than 2 mm are collected and processed. Additionally, a significant portion of the fragments recovered from the impact test are needle-like and/or flat plate-like fragments where their heights are almost negligible in comparison to their other dimensions. As a result, two fragment size categories were defined: 2D objects and 3D objects. While measurement systems are commercially available, factors such as measurement rates, system adaptability, size characterization limitations and equipment costs presented significant challenges to the project and a decision was made to develop our own size characterization systems. The size characterization systems consist of two automated image systems, one referred to as the 3D imaging system and the other as the 2D imaging system. Which imaging system to use depends on the classification of the fragment being measured. Both imaging systems utilize point-and-shoot cameras for object image acquisition and create representative point clouds of the fragments. The 3D imaging system utilizes a space-carving algorithm to generate a 3D point cloud, while the 2D imaging system utilizes an edge detection algorithm to generate a 2D point cloud. From the point clouds, the three largest orthogonal dimensions are determined using a convex hull algorithm. For 3D objects, in addition to the three largest orthogonal dimensions, the volume is computed via an alpha-shape algorithm applied to the point clouds. The average cross-sectional area is also computed for 3D objects. Both imaging systems have automated size measurements (image acquisition and image processing) driven by the need to quickly

  9. Remote optical sensor system for E-field measurements

    Heinzelmann, Robert; Stoehr, Andreas; Alder, Thomas; Kalinowski, D.; Schmidt, Manuel; Gross, Matthias; Jaeger, Dieter


    The concept of a remote optical sensor system for frequency selective electric field measurements will be presented. The system will be applicable to field measurement problems up to frequencies in the microwave regime. Additionally, it will provide minimum interference with the measured field, due to the optical fiber coupled sensor head. The electrooptic key components within the head of this sensor system are an array of photovoltaic cells and an electroabsorption waveguide modulator. Based on experimental results these components will be discussed and evaluated for the application within the sensor system. Furthermore, a novel fiber modulator coupling technique employing the monolithic integration of the device with InP V-grooves will be presented.

  10. Measurability and Safety Verification for Stochastic Hybrid Systems

    Fränzle, Martin; Hahn, Ernst Moritz; Hermanns, Holger;


    Dealing with the interplay of randomness and continuous time is important for the formal verification of many real systems. Considering both facets is especially important for wireless sensor networks, distributed control applications, and many other systems of growing importance. An important......-time behaviour is given by differential equations, as for usual hybrid systems, but the targets of discrete jumps are chosen by probability distributions. These distributions may be general measures on state sets. Also non-determinism is supported, and the latter is exploited in an abstraction and evaluation...... method that establishes safe upper bounds on reachability probabilities. To arrive there requires us to solve semantic intricacies as well as practical problems. In particular, we show that measurability of a complete system follows from the measurability of its constituent parts. On the practical side...

  11. Development of an integrated control and measurement system

    Manges, W.W.


    This thesis presents a tutorial on the issues involved in the development of a minicomputer-based, distributed intelligence data acquisition and process control system to support complex experimental facilities. The particular system discussed in this thesis is under development for the Atomic Vapor Laser Isotope Separation (AVLIS) Program at the Oak Ridge Gaseous Diffusion Plant (ORGDP). In the AVLIS program, we were careful to integrate the computer sections of the implementation into the instrumentation system rather than adding them as an appendage. We then addressed the reliability and availability of the system as a separate concern. Thus, our concept of an integrated control and measurement (ICAM) system forms the basis for this thesis. This thesis details the logic and philosophy that went into the development of this system and explains why the commercially available turn-key systems generally are not suitable. Also, the issues involved in the specification of the components for such an integrated system are emphasized.

  12. Bohmian mechanics, open quantum systems and continuous measurements

    Nassar, Antonio B


    This book shows how Bohmian mechanics overcomes the need for a measurement postulate involving wave function collapse. The measuring process plays a very important role in quantum mechanics. It has been widely analyzed within the Copenhagen approach through the Born and von Neumann postulates, with later extension due to Lüders. In contrast, much less effort has been invested in the measurement theory within the Bohmian mechanics framework. The continuous measurement (sharp and fuzzy, or strong and weak) problem is considered here in this framework. The authors begin by generalizing the so-called Mensky approach, which is based on restricted path integral through quantum corridors. The measuring system is then considered to be an open quantum system following a stochastic Schrödinger equation. Quantum stochastic trajectories (in the Bohmian sense) and their role in basic quantum processes are discussed in detail. The decoherence process is thereby described in terms of classical trajectories issuing from th...

  13. A complex network-based importance measure for mechatronics systems

    Wang, Yanhui; Bi, Lifeng; Lin, Shuai; Li, Man; Shi, Hao


    In view of the negative impact of functional dependency, this paper attempts to provide an alternative importance measure called Improved-PageRank (IPR) for measuring the importance of components in mechatronics systems. IPR is a meaningful extension of the centrality measures in complex network, which considers usage reliability of components and functional dependency between components to increase importance measures usefulness. Our work makes two important contributions. First, this paper integrates the literature of mechatronic architecture and complex networks theory to define component network. Second, based on the notion of component network, a meaningful IPR is brought into the identifying of important components. In addition, the IPR component importance measures, and an algorithm to perform stochastic ordering of components due to the time-varying nature of usage reliability of components and functional dependency between components, are illustrated with a component network of bogie system that consists of 27 components.

  14. Drone based measurement system for radiofrequency exposure assessment.

    Joseph, Wout; Aerts, Sam; Vandenbossche, Matthias; Thielens, Arno; Martens, Luc


    For the first time, a method to assess radiofrequency (RF) electromagnetic field (EMF) exposure of the general public in real environments with a true free-space antenna system is presented. Using lightweight electronics and multiple antennas placed on a drone, it is possible to perform exposure measurements. This technique will enable researchers to measure three-dimensional RF-EMF exposure patterns accurately in the future and at locations currently difficult to access. A measurement procedure and appropriate measurement settings have been developed. As an application, outdoor measurements are performed as a function of height up to 60 m for Global System for Mobile Communications (GSM) 900 MHz base station exposure. Bioelectromagnetics. © 2016 Wiley Periodicals, Inc.

  15. Low Power Shoe Integrated Intelligent Wireless Gait Measurement System

    Wahab, Y.; Mazalan, M.; Bakar, N. A.; Anuar, A. F.; Zainol, M. Z.; Hamzah, F.


    Gait analysis measurement is a method to assess and identify gait events and the measurements of dynamic, motion and pressure parameters involving the lowest part of the body. This significant analysis is widely used in sports, rehabilitation as well as other health diagnostic towards improving the quality of life. This paper presents a new system empowered by Inertia Measurement Unit (IMU), ultrasonic sensors, piezoceramic sensors array, XBee wireless modules and Arduino processing unit. This research focuses on the design and development of a low power ultra-portable shoe integrated wireless intelligent gait measurement using MEMS and recent microelectronic devices for foot clearance, orientation, error correction, gait events and pressure measurement system. It is developed to be cheap, low power, wireless, real time and suitable for real life in-door and out-door environment.

  16. Precise Measurement of Laser Power using an Optomechanical System

    Agatsuma, Kazuhiro; Ballmer, Stefan; DeSalvo, Giulia; Sakata, Shihori; Nishida, Erina; Kawamura, Seiji


    This paper shows a novel method to precisely measure the laser power using an optomechanical system. By measuring a mirror displacement caused by the reflection of an amplitude modulated laser beam, the number of photons in the incident continuous-wave laser can be precisely measured. We have demonstrated this principle by means of a prototype experiment uses a suspended 25 mg mirror as an mechanical oscillator coupled with the radiation pressure and a Michelson interferometer as the displacement sensor. A measurement of the laser power with an uncertainty of less than one percent (1 sigma) is achievable.

  17. A lidar system for measuring atmospheric pressure and temperature profiles

    Schwemmer, Geary K.; Dombrowski, Mark; Korb, C. Laurence; Milrod, Jeffry; Walden, Harvey


    The design and operation of a differential absorption lidar system capable of remotely measuring the vertical structure of tropospheric pressure and temperature are described. The measurements are based on the absorption by atmospheric oxygen of the spectrally narrowband output of two pulsed alexandrite lasers. Detailed laser output spectral characteristics, which are critical to successful lidar measurements, are presented. Spectral linewidths of 0.026 and 0.018 per cm for the lasers were measured with over 99.99 percent of the energy contained in three longitudinal modes.

  18. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu


    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.


    Petr Volf; Patrik Kutílek; Jiří Hozman; Rudolf Černý; Tomáš Koukolík; Jan Hejda


    The article deals with the design of a system for studying kinematics of movement of the vestibular system. Up to now there has not existed a system which would enable to measure the kinematic quantities of movement of the individual parts of the vestibular system within its coordinate system. The proposed system removes these deficiencies by suitable positioning of five gyro-accelerometric units on the helmet. The testing of the system took place under two conditions, during Unilateral Rotat...

  20. Method and System for Measuring Spinning YarnTension Using Image Measuring Technique

    梅顺齐; 宋志峰; 张智明


    A non-contact method and system for measuring spinning yarn tension is developed using an image processing technique and based on the theory of yarn balloon dynamics. The theoretical basis of the measurement is the relationship among yarn tension, balloon shape, and spinning parameters. The yarn tension is determined according to the geometric parameters of the balloon, which are measured from an image of the balloon. The digital image is captured with a CCD sensor, and processed in a computer using a wavelet transform technique. A measuring system is developed, and experiments are carried out. The results show that the proposed non-contact method is effective in the on-line measurement of spinning yarn tension for improving the degree of automation of the spinning machine.

  1. A System for Acoustic Field Measurement Employing Cartesian Robot

    Szczodrak Maciej


    Full Text Available A system setup for measurements of acoustic field, together with the results of 3D visualisations of acoustic energy flow are presented in the paper. Spatial sampling of the field is performed by a Cartesian robot. Automatization of the measurement process is achieved with the use of a specialized control system. The method is based on measuring the sound pressure (scalar and particle velocity(vector quantities. The aim of the system is to collect data with a high precision and repeatability. The system is employed for measurements of acoustic energy flow in the proximity of an artificial head in an anechoic chamber. In the measurement setup an algorithm for generation of the probe movement path is included. The algorithm finds the optimum path of the robot movement, taking into account a given 3D object shape present in the measurement space. The results are presented for two cases, first without any obstacle and the other - with an artificial head in the sound field.

  2. An inductive telemetric measurement system for humidity sensing

    Marioli, D.; Sardini, E.; Serpelloni, M.


    In some specific applications, the measuring environment can have unsuitable characteristics for a correct electronic functioning; it is not possible to connect a sensitive element to the conditioning electronics by standard cables or by a radiofrequency link. A possible solution could be a contactless link with a passive sensor inside the measuring environment and a readout outside. This paper discusses the telemetric system consisting of two contactless coupled planar inductors. The two inductors form a coupled transformer in air, with the primary one connected to the measurement electronics and the secondary one working as the sensitive element. A polymer deposited on the secondary one is sensible to the humidity, and changes its dielectric permittivity causing a variation of the inductor parasitic capacitance. A conditioning electronics measures frequency resonances, while the system extracts the corresponding capacitance values, compensating the distance variation as well. The whole system has been tested in the laboratory, and several results have been reported. These show about 200 fF variation over 1.7 pF for a change of the RH between 60% and 90% at a constant temperature of 22 °C. Moreover, the measured data are compensated on distance variation changing from 15 mm up to 30 mm. The complete explanation of the whole measurement system is described here. The low cost of the sensors and conditioning electronics implies a high diffusion in many application fields, from food packages to automotive.

  3. Temperature and voltage measurement in quantum systems far from equilibrium

    Shastry, Abhay; Stafford, Charles A.


    We show that a local measurement of temperature and voltage for a quantum system in steady state, arbitrarily far from equilibrium, with arbitrary interactions within the system, is unique when it exists. This is interpreted as a consequence of the second law of thermodynamics. We further derive a necessary and sufficient condition for the existence of a solution. In this regard, we find that a positive temperature solution exists whenever there is no net population inversion. However, when there is a net population inversion, we may characterize the system with a unique negative temperature. Voltage and temperature measurements are treated on an equal footing: They are simultaneously measured in a noninvasive manner, via a weakly coupled thermoelectric probe, defined by requiring vanishing charge and heat dissipation into the probe. Our results strongly suggest that a local temperature measurement without a simultaneous local voltage measurement, or vice versa, is a misleading characterization of the state of a nonequilibrium quantum electron system. These results provide a firm mathematical foundation for voltage and temperature measurements far from equilibrium.

  4. SPECTRON, a neutron noise measurement system in frequency domain.

    de Izarra, G; Jammes, C; Geslot, B; Di Salvo, J; Destouches, C


    This paper is dedicated to the presentation and validation of SPECTRON, a novel neutron noise measurement system developed at CEA Cadarache. The device is designed for the measurement of the β(eff) parameter (effective fraction of delayed neutrons) of experimental nuclear reactors using the Cohn-α method. An integrated electronic system is used to record the current from fission chambers. Spectra computed from measurement data are processed by a dedicated software in order to estimate the reactor transfer function and then the effective fraction of delayed neutrons as well as the prompt neutron generation time. After a review of the pile noise measurement method in current mode, the SPECTRON architecture is presented. Then, the validation procedure is described and experimental results are shown, supporting the proper functioning of this new measurement system. It is shown that every technical requirement needed for correct measurement of neutron noise is fulfilled. Measurements performed at MINERVE and EOLE, two experimental nuclear reactors at CEA Cadarache, in real conditions allowed us to validate SPECTRON.

  5. Calibration system for measuring the radon flux density.

    Onishchenko, A; Zhukovsky, M; Bastrikov, V


    The measurement of radon flux from soil surface is the useful tool for the assessment of radon-prone areas and monitoring of radon releases from uranium mining and milling residues. The accumulation chambers with hollow headspace and chambers with activated charcoal are the most used devices for these purposes. Systematic errors of the measurements strongly depend on the geometry of the chamber and diffusion coefficient of the radon in soil. The calibration system for the attestation of devices for radon flux measurements was constructed. The calibration measurements of accumulation chambers and chambers with activated charcoal were conducted. The good agreement between the results of 2D modelling of radon flux and measurements results was observed. It was demonstrated that reliable measurements of radon flux can be obtained by chambers with activated charcoal (equivalent volume ~75 l) or by accumulation chambers with hollow headspace of ~7-10 l and volume/surface ratio (height) of >15 cm.

  6. Certified quantum non-demolition measurement of material systems

    Mitchell, M. W.; Koschorreck, M.; Kubasik, M.; Napolitano, M.; Sewell, R. J.


    An extensive debate on quantum non-demolition (QND) measurement, reviewed in Grangier et al (1998 Nature 396 537), finds that true QND measurements must have both non-classical state-preparation capability and non-classical information-damage tradeoff. Existing figures of merit for these non-classicality criteria require direct measurement of the signal variable and are thus difficult to apply to optically-probed material systems. Here we describe a method to demonstrate both criteria without need for to direct signal measurements. Using a covariance matrix formalism and a general noise model, we compute meter observables for QND measurement triples, which suffice to compute all QND figures of merit. The result will allow certified QND measurement of atomic spin ensembles using existing techniques.

  7. Certified quantum non-demolition measurement of material systems

    Mitchell, Morgan W; Kubasik, Marcin; Napolitano, Mario; Sewell, Robert J


    An extensive debate on quantum non-demolition (QND) measurement, reviewed in Grangier et al. [Nature, {\\bf 396}, 537 (1998)], finds that true QND measurements must have both non-classical state-preparation capability and non-classical information-damage tradeoff. Existing figures of merit for these non-classicality criteria require direct measurement of the signal variable and are thus difficult to apply to optically-probed material systems. Here we describe a method to demonstrate both criteria without need for to direct signal measurements. Using a covariance matrix formalism and a general noise model, we compute meter observables for QND measurement triples, which suffice to compute all QND figures of merit. The result will allow certified QND measurement of atomic spin ensembles using existing techniques.

  8. Risk measures for power failures in transmission systems

    Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye


    We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.

  9. Risk measures for power failures in transmission systems.

    Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye


    We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.

  10. Mammographic density measurements are not affected by mammography system.

    Damases, Christine N; Brennan, Patrick C; McEntee, Mark F


    Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman's density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists' visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer's equipment affects a woman's MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation ([Formula: see text]; [Formula: see text]), while the VDG ([Formula: see text]; [Formula: see text]) and AvBD% ([Formula: see text]; [Formula: see text]) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS ([Formula: see text]; [Formula: see text]), however, the systems demonstrated an almost perfect agreement for VDG ([Formula: see text]; [Formula: see text]).

  11. Development of a Wireless Displacement Measurement System Using Acceleration Responses

    Billie F. Spencer Jr.


    Full Text Available Displacement measurements are useful information for various engineering applications such as structural health monitoring (SHM, earthquake engineering and system identification. Most existing displacement measurement methods are costly, labor-intensive, and have difficulties particularly when applying to full-scale civil structures because the methods require stationary reference points. Indirect estimation methods converting acceleration to displacement can be a good alternative as acceleration transducers are generally cost-effective, easy to install, and have low noise. However, the application of acceleration-based methods to full-scale civil structures such as long span bridges is challenging due to the need to install cables to connect the sensors to a base station. This article proposes a low-cost wireless displacement measurement system using acceleration. Developed with smart sensors that are low-cost, wireless, and capable of on-board computation, the wireless displacement measurement system has significant potential to impact many applications that need displacement information at multiple locations of a structure. The system implements an FIR-filter type displacement estimation algorithm that can remove low frequency drifts typically caused by numerical integration of discrete acceleration signals. To verify the accuracy and feasibility of the proposed system, laboratory tests are carried out using a shaking table and on a three storey shear building model, experimentally confirming the effectiveness of the proposed system.

  12. Towards a smart non-invasive fluid loss measurement system.

    Suryadevara, N K; Mukhopadhyay, S C; Barrack, L


    In this article, a smart wireless sensing non-invasive system for estimating the amount of fluid loss, a person experiences while physical activity is presented. The system measures three external body parameters, Heart Rate, Galvanic Skin Response (GSR, or skin conductance), and Skin Temperature. These three parameters are entered into an empirically derived formula along with the user's body mass index, and estimation for the amount of fluid lost is determined. The core benefit of the developed system is the affluence usage in combining with smart home monitoring systems to care elderly people in ambient assisted living environments as well in automobiles to monitor the body parameters of a motorist.

  13. Magnetic-Field-Response Measurement-Acquisition System

    Woodward, Stanley E.; Shams, Qamar A.; Fox, Robert L.; Taylor, Bryant D.


    A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a

  14. Research on Accuracy of Automatic System for Casting Measuring

    Jaworski J.


    Full Text Available Ensuring the required quality of castings is an important part of the production process. The quality control should be carried out in a fast and accurate way. These requirements can be met by the use of an optical measuring system installed on the arm of an industrial robot. In the article a methodology for assessing the quality of robotic measurement system to control certain feature of the casting, based on the analysis of repeatability and reproducibility is presented. It was shown that industrial robots equipped with optical measuring systems have the accuracy allowing their use in the process of dimensional control of castings manufactured by lost-wax process, permanent-mould casting, and pressure die-casting.

  15. Measurement system for nitrous oxide based on amperometric gas sensor

    Siswoyo, S.; Persaud, K. C.; Phillips, V. R.; Sneath, R.


    It has been well known that nitrous oxide is an important greenhouse gas, so monitoring and control of its concentration and emission is very important. In this work a nitrous oxide measurement system has been developed consisting of an amperometric sensor and an appropriate lab-made potentiostat that capable measuring picoampere current ranges. The sensor was constructed using a gold microelectrode as working electrode surrounded by a silver wire as quasi reference electrode, with tetraethyl ammonium perchlorate and dimethylsulphoxide as supporting electrolyte and solvent respectively. The lab-made potentiostat was built incorporating a transimpedance amplifier capable of picoampere measurements. This also incorporated a microcontroller based data acquisition system, controlled by a host personal computer using a dedicated computer program. The system was capable of detecting N2O concentrations down to 0.07 % v/v.

  16. Working fluid concentration measurement in solar air conditioning systems

    Romero, R.J.; Basurto-Pensado, M.A. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001. Col. Chamilpa, C.P. 62210, Cuernavaca, Morelos (Mexico); Jimenez-Heredia, A.H.; Sanchez-Mondragon, J.J. [Departamento de Optica, Instituto Nacional de Astrofisica Optica y Electronica, Luis Enrique Erro No. 1, Tonantzintla, Apartado Postal 51 y 216, C.P. 72000, Puebla (Mexico)


    In order to evaluate on-line corrosive electrolyte concentration in solar air conditioning systems, an optical technique to determine the concentration is being proposed. With this optical sensing method, it is possible to measure the percentage concentration of the aqueous corrosive lithium bromide solution at temperatures ranging from 25{sup o}C to 70{sup o}C and a maximum concentration of 60%. The measurement system is based on the refractive index of the solution and the data correlation, at several temperature and concentration values. The results of this work present a direct method for concentration measurement of corrosive liquids and also show the correlation among the three parameters: refractive index, temperature and weight concentration. This correlation can be used to develop the optical device for solar air conditioning systems to control and improve efficiency. (author)

  17. Measure of the Quantum Speedup in Closed and Open systems

    Xu, Zhen-Yu

    We construct a general measure for detecting the quantum speedup in both closed and open systems. This speed measure is based on the changing rate of the position of quantum states on a manifold with appropriate monotone Riemannian metrics. Any increase in speed is a clear signature of real dynamical speedup. To clarify the mechanisms of quantum speedup, we first introduce the concept of longitudinal and transverse types of speedup, and then apply the proposed measure to several typical closed and open quantum systems, illustrating that entanglement and the memory effect of the environment together can become resources for longitudinally or transversely accelerating dynamical evolution under certain conditions. Remarkably, a direct measurement of such speedup is feasible without the need for a tomographic reconstruction of the density matrix, which greatly enhances the feasibility of practical experimental tests. This work was supported by the National Natural Science Foundation of China (Grant No. 11204196).

  18. [A focused sound field measurement system by LabVIEW].

    Jiang, Zhan; Bai, Jingfeng; Yu, Ying


    In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.

  19. Characterization of defects in n-type 4H-SiC after high-energy N ion implantation by RBS-channeling and Raman spectroscopy

    Kummari, Venkata C.; Reinert, Tilo; Jiang, Weilin; McDaniel, Floyd D.; Rout, Bibhudutta


    Implantation with 1 MeV N ions was performed at room temperature in n-type 4H-SiC (0 0 0 1) at four implantation fluences (or doses in dpa (displacements per atom) at the damage peak) of 1.5 × 1013 (0.0034), 7.8 × 1013 (0.018), 1.5 × 1014 (0.034), and 7.8 × 1014 (0.178) ions/cm2, respectively. The evolution of disorder was studied using Rutherford backscattering spectrometry in channeling mode (RBS-C), Raman spectroscopy, and optical transmission. The disorder in the Si sub-lattice was found to be less than 10% for the dpa of 0.0034 and 0.0178 and increased to 40% and 60% for the dpa of 0.034 and 0.178 respectively. The normalized Raman intensity In, shows disorder of 41%, 69%, 77% and 100% for the dpa of 0.0034, 0.0178, 0.034 and 0.178, respectively. In this paper, the characterization of the defects produced due to the nitrogen implantation in 4H-SiC are presented and the results are discussed.

  20. Study on a transient optical fiber high temperature measurement system

    Cai, Lulu; Liu, Yusha; Wang, Yutian


    High temperature is one of the most important parameters in the fields of scientific research and industrial production. At present, thermocouple, thermo resistive and radiance thermometer are already technologically mature which can be adopted to measure the general temperature, but when it comes to the transient high temperature that changes pretty quickly in wretched conditions, those traditional pyrometers can not meet the requirements any more. In this paper, we designed a transient optical high temperature measurement system. First, design of the temperature measurement probe. The system took blackbody cavity sensor together with optical fiber to receive the measured signal, here, the integrated emissivity model of the blackbody cavity was established and the optimum structure parameters were confirmed. Secondly, design of the entire temperature measurement system. A contact-noncontact measurement method was applied, which is to make the blackbody cavity and the measured high-temperature source contact, the fiber probe and the blackbody cavity noncontact, as a result, the error caused by contact measurement is overcame and the precision is guaranteed at the same time. In addition, a fiber grating was introduced as the wavelength filter device which can realize the dynamic filter of narrow-band signals and reduce the impact of background light. Thirdly, signal processing. In this part, we applied labVIEW software and wavelet analysis method. All of the signal acquisition and processing were realized in the labVIEW environment. Through calling matlab in labVIEW, the signals from optical fiber detector were wavelet denoised and decomposed, thus the temperature information was extracted, and the temperature value was obtained. On basis of wavelet transformation, the paper adopted the 4dB wavelet with horizontal scale of 5 to realize the feature extraction and noise removal, parts of the signals before and after the wavelet noise removal were given and analyzed

  1. On reactive oxygen species measurement in living systems


    Studies devoted to the detection and measurement of free radicals in biological systems generally generated accepted methods of reactive oxygen species (ROS) level analysis. When out of control, ROS induces tissue damage, chronic inflammatory processes and cellular functional disturbances. Aerobic organisms have adapted to defense against ROS aggression by developing potent antioxidant mechanisms. Recent advances in ROS measurement methodology allow the study of ROS biology at a previously un...

  2. Multifractal Measure of Post Distribution in Post System

    CHEN Li; HUANG Deng-shi


    In order to investigate the true post distribution in the whole society, microelasticity (MIE) and macroelasticity (MAE) were defined by regarding all posts as a system. On this basis, the method for measuring post distribution was proposed. Using the Legendre dual transformation between MIE and MAE to highlight the probabilities of different levels, the post distribution were analyzed hierarchically. The two-scale Cantor model verified that the multifractal measure is applicable to the post distribution evolution process.

  3. Laser Tracker Calibration - Testing the Angle Measurement System -

    Gassner, Georg; Ruland, Robert; /SLAC


    Physics experiments at the SLAC National Accelerator Laboratory (SLAC) usually require high accuracy positioning, e. g. 100 {micro}m over a distance of 150 m or 25 {micro}m in a 10 x 10 x 3 meter volume. Laser tracker measurement systems have become one of the most important tools for achieving these accuracies when mapping components. The accuracy of these measurements is related to the manufacturing tolerances of various individual components, the resolutions of measurement systems, the overall precision of the assembly, and how well imperfections can be modeled. As with theodolites and total stations, one can remove the effects of most assembly and calibration errors by measuring targets in both direct and reverse positions and computing the mean to obtain the result. However, this approach does not compensate for errors originating from the encoder system. In order to improve and gain a better understanding of laser tracker angle measurement tolerances we extended our laboratory's capabilities with the addition of a horizontal angle calibration test stand. This setup is based on the use of a high precision rotary table providing an angular accuracy of better than 0.2 arcsec. Presently, our setup permits only tests of the horizontal angle measurement system. A test stand for vertical angle calibration is under construction. Distance measurements (LECOCQ & FUSS, 2000) are compared to an interferometer bench for distances of up to 32 m. Together both tests provide a better understanding of the instrument and how it should be operated. The observations also provide a reasonable estimate of covariance information of the measurements according to their actual performance for network adjustments.

  4. System and method for measuring fluorescence of a sample

    Riot, Vincent J.


    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  5. System and method for measuring fluorescence of a sample

    Riot, Vincent J


    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  6. Application of Phosphor Thermometry to a Galvanneal Temperature Measurement System

    Beshears, D.L.; Allison, S.W.; Andrews, W.H.; Cates, M.R.; Grann, E.B.; Manges, W.W.; McIntyre, T.J.; Scudiere, M.B.; Simpson, M.L.; Childs, R.M.; Vehec, J.; Zhang, L.


    The Galvanneal Temperature Measurement System (GTMS) was developed for the American Iron and Steel Institute by the Oak Ridge National Laboratory through a partnership with the National Steel Midwest Division in Portage, Indiana. The GTMS provides crucial on-line thermal process control information during the manufacturing of galvanneal steel. The system has been used with the induction furnaces to measure temperatures ranging from 840 to 1292 F with an accuracy of better than {+-}9 F. The GTMS provides accurate, reliable temperature information thus ensuring a high quality product, reducing waste, and saving energy. The production of uniform, high-quality galvanneal steel is only possible through strict temperature control.

  7. Surface moisture measurement system hardware acceptance test report

    Ritter, G.A., Westinghouse Hanford


    This document summarizes the results of the hardware acceptance test for the Surface Moisture Measurement System (SMMS). This test verified that the mechanical and electrical features of the SMMS functioned as designed and that the unit is ready for field service. The bulk of hardware testing was performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. The SMMS was developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks.

  8. Performance of the APS optical slope measuring system

    Qian, Jun, E-mail: [Advanced Photon Source, Argonne National Laboratory, 9700S. Cass Avenue, Argonne, 60439 (United States); Sullivan, Joe; Erdmann, Mark; Khounsary, Ali; Assoufid, Lahsen [Advanced Photon Source, Argonne National Laboratory, 9700S. Cass Avenue, Argonne, 60439 (United States)


    An optical slope measuring system (OSMS) was recently brought into operation at the Advanced Photon Source of the Argonne National Laboratory. This system is equipped with a precision autocollimator and a very accurate mirror-based pentaprism on a scanning stage and kept in an environment-controlled enclosure. This system has the capability to measure precision optics with sub-microradian rms slope errors as documented with a series of tests demonstrating accuracy, stability, reliability and repeatability. Measurements of a flat mirror with 0.2 μrad rms slope error are presented which show that the variation of the slope profile measurements with the mirror setting at different locations along the scanning direction is only 60 nrad and the corresponding height error profile has 2 nm rms. -- Highlights: ► This is the first time to present the APS OSMS in publication. ► The APS OSMS is capable to measure flat and near flat mirrors with slope error <100 nrad rms. ► The accuracy of the slope error measurements of a 350 mm long mirror is less than 60 nrad rms.

  9. WSN-Based Space Charge Density Measurement System.

    Deng, Dawei; Yuan, Haiwen; Lv, Jianxun; Ju, Yong


    It is generally acknowledged that high voltage direct current (HVDC) transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN) shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the construction of distributed space charge density monitoring system as it has longer distance and higher mobility. A distributed wireless system is designed for collecting and monitoring the space charge density under HVDC transmission lines, which has been widely applied in both Chinese state grid HVDC test base and power transmission projects. Experimental results of the measuring system demonstrated its adaptability in the complex electromagnetic environment under the transmission lines and the ability in realizing accurate, flexible, and stable demands for the measurement of space charge density.

  10. Study on risk measurement about ammunition-rocket system

    Gu Xiaohui; Zhao Youshou


    Modern ammunition-rocket system is a complicated multidisciplinary system. During its development,undetermined factors will bring many risks. This paper elaborates the importance of risk analysis approach to ammunition-rocket system development and analyses various methods of risk analysis and estimation. Combined with practical situation of weapon system development, the risk measurement function with characteristics of risk preference is given provided that the risk preference characteristic of behavior maker is risk neutral of fixed constant. The development risk analysis based on risk measurement function enables effective risk decision to be made on the basis of quantified risk.Taking anti-helicopter intelligent mine warhead as an example, the paper verifies the efficiency of the method and shows that it has a scientific and practical value.

  11. Guide to Flow Measurement for Electric Propulsion Systems

    Frieman, Jason D.; Walker, Mitchell L. R.; Snyder, Steve


    In electric propulsion (EP) systems, accurate measurement of the propellant mass flow rate of gas or liquid to the thruster and external cathode is a key input in the calculation of thruster efficiency and specific impulse. Although such measurements are often achieved with commercial mass flow controllers and meters integrated into propellant feed systems, the variability in potential propellant options and flow requirements amongst the spectrum of EP power regimes and devices complicates meter selection, integration, and operation. At the direction of the Committee on Standards for Electric Propulsion Testing, a guide was jointly developed by members of the electric propulsion community to establish a unified document that contains the working principles, methods of implementation and analysis, and calibration techniques and recommendations on the use of mass flow meters in laboratory and spacecraft electric propulsion systems. The guide is applicable to EP devices of all types and power levels ranging from microthrusters to high-power ion engines and Hall effect thrusters. The establishment of a community standard on mass flow metering will help ensure the selection of the proper meter for each application. It will also improve the quality of system performance estimates by providing comprehensive information on the physical phenomena and systematic errors that must be accounted for during the analysis of flow measurement data. This paper will outline the standard methods and recommended practices described in the guide titled "Flow Measurement for Electric Propulsion Systems."

  12. A miniature, low cost CTD system for coastal salinity measurements

    Broadbent, Heather A.; Ivanov, Stanislav Z.; Fries, David P.


    In this work we describe a small, low cost conductivity, temperature and depth (CTD) system for measurements of salinity in coastal waters. The system incorporates three low cost expendable sensors, a novel planar four-electrode conductivity cell, a planar resistive temperature device and a piezoelectric pressure sensor. The conductivity cell and the resistive temperature device were fabricated using novel printed circuit board (PCB) microelectromechanical (MEMS) techniques combined with a new thin-film material, liquid crystal polymer (LCP). Printed circuit board techniques allow for mass production of the sensors, thereby lowering the cost of the system. The three sensors are packaged so that they are independent of one another and can be quickly replaced if bio-fouled or damaged. Deployments in Bayboro Harbor, St Petersburg, FL demonstrate that the novel CTD systems are capable of obtaining highly resolved in situ salinity measurements comparable to measurements obtained using commercially available instruments. The estimated accuracies for the conductivity, temperature and pressure sensors are ±1.47%, ±0.546 °C and ±0.02 bar, respectively. This work indicates that a small, low cost CTD system with expendable/replaceable sensors can be used to provide accurate, precise and highly resolved conductivity, temperature and pressure measurements in a coastal environment.


    I. V. Zhukovytskyy


    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  14. Invariant measures and controllability of finite systems on compact manifolds

    Jouan, Philippe


    A control system is said to be finite if the Lie algebra generated by its vector fields is finite dimensional. Sufficient conditions for such a system on a compact manifold to be controllable are stated in terms of its Lie algebra. The proofs make use of the Equivalence Theorem of \\cite{Jouan09} and of the existence of an invariant measure on certain compact homogeneous spaces.

  15. Integration Of GPS And GLONASS Systems In Geodetic Satellite Measurements

    Maciuk, Kamil


    The article shows the results of satellites measurements elaborations using GPS & GLONASS signals. The aim of this article is to define the influence of adding GLONASS signals on position determination accuracy. It especially concerns areas with big horizon coverages. Object of the study were analysis of DOP coefficients, code and RTK solutions, and usage of satellite techniques in levelling. The performed studies and analysis show that integrated GPS-GLONASS satellite measurements provide possibility to achieve better results than measurements using single navigation satellite system (GPS).

  16. Workflow logs analysis system for enterprise performance measurement


    Workflow logs that record the execution of business processes offer very valuable data resource for real-time enterprise performance measurement. In this paper, a novel scheme that uses the technology of data warehouse and OLAP to explore workflow logs and create complex analysis reports for enterprise performance measurement is proposed. Three key points of this scheme are studied: 1) the measure set; 2) the open and flexible architecture for workflow logs analysis system; 3) the data models in WFMS and data warehouse. A case study that shows the validity of the scheme is also provided.

  17. Microscopic Faraday rotation measurement system using pulsed magnetic fields.

    Egami, Shigeki; Watarai, Hitoshi


    Microscopic Faraday rotation measurement system using a pulsed magnetic field has been constructed, which can be applied to micron sized diamagnetic and paramagnetic materials. A pulsed magnetic coil could generate a maximum magnetic flux density of about 12 T. The performance of the microscopic Faraday rotation apparatus was demonstrated by the measurement of the Verdet constant V of a polystyrene particle, after the calibration of the pulsed magnetic flux density using a glass plate as a standard material. Also, the magneto-optical rotation dispersion of some diamagnetic substances have been measured and analyzed with V=alambda(-2)+b. The values of a and b were compared to their magnetic susceptibilities.

  18. System to Measure Thermal Conductivity and Seebeck Coefficient for Thermoelectrics

    Kim, Hyun-Jung; Skuza, Jonathan R.; Park, Yeonjoon; King, Glen C.; Choi, Sang H.; Nagavalli, Anita


    The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at elevated temperatures. This has led to the implementation of nonstandardized practices that have further complicated the confirmation of reported high ZT materials. The major objective of the procedure described is for the simultaneous measurement of the Seebeck coefficient and thermal diffusivity within a given temperature range. These thermoelectric measurements must be precise, accurate, and reproducible to ensure meaningful interlaboratory comparison of data. The custom-built thermal characterization system described in this NASA-TM is specifically designed to measure the inplane thermal diffusivity, and the Seebeck coefficient for materials in the ranging from 73 K through 373 K.

  19. Non-disruptive measurement system of cell viability in bioreactors

    Rudek, F.; Nelsen, B. L.; Baselt, T.; Berger, T.; Wiele, M.; Prade, I.; Hartmann, P.


    Nutrient and oxygen transport, as well as the removal of metabolic waste are essential processes to support and maintain viable tissue. Current bioreactor technology used to grow tissue cultures in vitro has a fundamental limit to the thickness of tissues. Based on the low diffusion limit of oxygen a maximum tissue thickness of 200 μm is possible. The efficiency of those systems is currently under investigation. During the cultivation process of the artificial tissue in bioreactors, which lasts 28 days or longer, there are no possibilities to investigate the viability of cells. This work is designed to determine the influence of a non-disruptive cell viability measuring system on cellular activity. The measuring system uses a natural cellular marker produced during normal metabolic activity. Nicotinamide adenine dinucleotide (NADH) is a coenzyme naturally consumed and produced during cellular metabolic processes and has thoroughly been studied to determine the metabolic state of a cell. Measuring the fluorescence of NADH within the cell represents a non-disruptive marker for cell viability. Since the measurement process is optical in nature, NADH fluorescence also provides a pathway for sampling at different measurement depths within a given tissue sample. The measurement system we are using utilizes a special UV light source, to excite the NADH fluorescence state. However, the high energy potentially alters or harms the cells. To investigate the influence of the excitation signal, the cells were irradiated with a laser operating at a wavelength of 355 nm and examined for cytotoxic effects. The aim of this study was to develop a non-cytotoxic system that is applicable for large-scale operations during drug-tissue interaction testing.

  20. Design and research on inverted focometer measured focal length of measuring system

    Tong, Yilin; Han, Xuecai


    Inverted focometer is a transformation of the traditional focomete, and optical lens focal length is an important technical indicators of optical system.The inverted focometer was used to measure the optical lens focal length, an expression between the ruling span of poroo-plate glass and the focal length of measured optical system was deduced according to inverted focometer design, the S-F figure graphic representation was developed , the S-F graph which could express relation of data was obtained, and steps of designing poroo-plate glass were analyzed .The S-F figure graphic representation is simple, intuitive and easy to design.

  1. Software Sub-system in Loading Automatic Test System for the Measurement of Power Line Filters

    Yu Bo


    Full Text Available The loading automatic test system for measurement of power line filters are in urgent demand. So the software sub-system of the whole test system was proposed. Methods: structured the test system based on the virtual instrument framework, which consisted of lower and up computer and adopted the top down approach of design to perform the system and its modules, according to the measurement principle of the test system. Results: The software sub-system including human machine interface, data analysis and process software, expert system, communication software, control software in lower computer, etc. had been designed. Furthermore, it had been integrated into the entire test system. Conclusion: This sub-system provided a fiendly software platform for the whole test system, and had many advantages such as strong functions, high performances, low prices. It not only raises the test efficiency of EMI filters, but also renders some creativities.

  2. Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS)

    Bland, Geoffrey [NASA Goddard Space Flight Center (GSFC), Greenbelt, MD (United States)


    The use of small unmanned aircraft systems (sUAS) with miniature sensor systems for atmospheric research is an important capability to develop. The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) project, lead by Dr. Gijs de Boer of the Cooperative Institute for Research in Environmental Sciences (CIRES- a partnership of NOAA and CU-Boulder), is a significant milestone in realizing this new potential. This project has clearly demonstrated that the concept of sUAS utilization is valid, and miniature instrumentation can be used to further our understanding of the atmospheric boundary layer in the arctic.

  3. Global Precipitation Measurement (GPM) Mission: NASA Precipitation Processing System (PPS)

    Stocker, Erich Franz


    NASA is contributing the precipitation measurement data system PPS to support the GPM mission. PPS will distribute all GPM data products including NASA s GMI data products freely and quickly. PPS is implementing no system mechanisms for restricting access to GPM data. PPS is implementing no system mechanisms for charging for GPM data products. PPS will provide a number of geographical and parameter subsetting features available to its users. The first implementation of PPS (called PPS--) will assume processing of TRMM data effective 1 June 2008. TRMM realtime data will be available via PPS- to all users requesting access

  4. Real-time deformation measurement using a transportable shearography system

    Weijers, A. L.; van Brug, Hedser H.; Frankena, Hans J.


    A new system for deformation visualization has been developed, being a real time phase stepped shearing speckle interferometer. This system provides the possibility to measure quantitatively deformations of diffusely reflecting objects in an industrial environment. The main characteristics of this interferometer are its speed of operation and its reduced sensitivity to external disturbances. Apart from its semiconductor laser source, this system has a shoe-box size and is mounted on a tripod for easy handling during inspection. This paper describes the shearing speckle interferometry set-up, as it is developed at our laboratory and its potential for detecting defects.


    О. Сущенко


    Full Text Available The paper is devoted to research of the field of application of the modern information-measuringsystems inertial stabilization. The characteristics of the basic applications of the systems for theinertial stabilization of the information-measuring devices mounted at the ground vehicles, thedirection-finding devices, the optical sensors, the mobile antennas for satellite communication aredescribed in the paper. Basic features of these applications, which influence on organization of theeffective procedures for stabilizing systems design, are represented. The research results are ofinterest of the field of the wide class vehicle control systems

  6. Photonic Delay-line Phase Noise Measurement System


    combined 500-m and 6-km delay-line measurement system. Noise floor data are shown for the system with and without an EDFA . The laser power was 10 dBm...The optical power into the photodiode was 0 dBm without the EDFA and 11 dBm with are shown for the system with and without an EDFA as well as with a high-power laser. The output optical powers of the low and high-power

  7. Automatic quadrature control and measuring system. [using optical coupling circuitry

    Hamlet, J. F. (Inventor)


    A quadrature component cancellation and measuring system comprising a detection system for detecting the quadrature component from a primary signal, including reference circuitry to define the phase of the quadrature component for detection is described. A Raysistor optical coupling control device connects an output from the detection system to a circuit driven by a signal based upon the primary signal. Combining circuitry connects the primary signal and the circuit controlled by the Raysistor device to subtract quadrature components. A known current through the optically sensitive element produces a signal defining the magnitude of the quadrature component.

  8. Calorimetric Measuring Systems for Characterizing High Frequency Power Losses in Power Electronic Components and Systems

    Blaabjerg, Frede; Pedersen, John Kim; Ritchie, Andrew Ewen


    two different calorimetric measuring systems, one for power losses up to 50 W and one for power losses up to 1500 W. These differ in size and also the systems which can be analysed. The basic concept of calorimetry is discussed and the overall performance of the two systems is specified. Methods...... to calibrate such systems are proposed and different applications of the system are given. Two practical examples end the description of the research. It is concluded that such systems have a relative long time-constant but they are accurate and useful for precise power loss measurement....

  9. Job Performance Measurement System Trainer’s Manual.


    When assessing the job proficiency of individuals, it is essential that evaluators receive training to increase the accuracy of their ratings. A job ... performance measurement system trainer’s manual was developed for use in training Walk-Through Performance Testing test administrators and raters

  10. 45 CFR 2543.15 - Metric system of measurement.


    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Metric system of measurement. 2543.15 Section 2543.15 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON...

  11. gLite Workload Management System Performance Measurements

    Svraka, N; Belic, A; Bogojevic, A R


    In this paper an introduction to the gLite Grid middleware and one of its most important components, Workload Management System (WMS), responsible for management of user jobs is given.Useful performance metrics of gLite WMS are defined from a Grid application point of view, and preliminary results of performance measurements are presented and briefly analyzed.

  12. Design of Customer Satisfaction Measurement Index System of EMS Service


    This paper discusses the design of a customer satisfaction measurement index system of erpress mail service. It presents objectives and principles of the design based on hierarchical structures. We have devised a diagram for modeling customer satisfaction, and a detailed analysis of customer satisfaction is conducted. This paper presents our customer satisfaction model and analysis results.

  13. Pico amp measurement circuit with high system isolation

    Akins, J.H.


    An increase in sensitivity of 2000 can be achieved by modifying a Tektronics P6042 Hall Effect probe to accept 2000 turns as opposed to the standard single turn current input line. This increase in sensitivity coupled with a special self-zeroing amplifier allows the measurement of Pico-amps while maintaining high system isolation.

  14. A Computer Controlled Precision High Pressure Measuring System

    Sadana, S.; Yadav, S.; Jha, N.; Gupta, V. K.; Agarwal, R.; Bandyopadhyay, A. K.; Saxena, T. K.


    A microcontroller (AT89C51) based electronics has been designed and developed for high precision calibrator based on Digiquartz pressure transducer (DQPT) for the measurement of high hydrostatic pressure up to 275 MPa. The input signal from DQPT is converted into a square wave form and multiplied through frequency multiplier circuit over 10 times to input frequency. This input frequency is multiplied by a factor of ten using phased lock loop. Octal buffer is used to store the calculated frequency, which in turn is fed to microcontroller AT89C51 interfaced with a liquid crystal display for the display of frequency as well as corresponding pressure in user friendly units. The electronics developed is interfaced with a computer using RS232 for automatic data acquisition, computation and storage. The data is acquired by programming in Visual Basic 6.0. This system is interfaced with the PC to make it a computer controlled system. The system is capable of measuring the frequency up to 4 MHz with a resolution of 0.01 Hz and the pressure up to 275 MPa with a resolution of 0.001 MPa within measurement uncertainty of 0.025%. The details on the hardware of the pressure measuring system, associated electronics, software and calibration are discussed in this paper.

  15. 77 FR 20789 - Work Group on Measuring Systems for Taxis


    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF COMMERCE National Institute of Standards and Technology Work Group on Measuring Systems for Taxis AGENCY: National... Standards and Technology (NIST) is forming a Work Group (WG) to develop proposals to revise the...

  16. 10 CFR 600.306 - Metric system of measurement.


    ... 10 Energy 4 2010-01-01 2010-01-01 false Metric system of measurement. 600.306 Section 600.306 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL ASSISTANCE RULES Administrative Requirements for Grants and Cooperative Agreements With For-Profit Organizations General § 600.306...

  17. 7 CFR 3019.15 - Metric system of measurement.


    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Metric system of measurement. 3019.15 Section 3019.15 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER... HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 3019.15...

  18. Designing a 3rd generation, authenticatable attribute measurement system

    Thron, Jonathan [Los Alamos National Laboratory; Karpius, Peter [Los Alamos National Laboratory; Santi, Peter [Los Alamos National Laboratory; Smith, Morag [Los Alamos National Laboratory; Vo, Duc [Los Alamos National Laboratory; Williams, Richard [Los Alamos National Laboratory


    Attribute measurement systems (AMS) are designed to measure potentially sensitive items containing Special Nuclear Materials to determine if the items possess attributes which fall within an agreed-upon range. Such systems could be used in a treaty to inspect and verify the identity of items in storage without revealing any sensitive information associated with the item. An AMS needs to satisfy two constraints: the host party needs to be sure that none of their sensitive information is released, while the inspecting party wants to have confidence that the limited amount of information they see accurately reflects the properties of the item being measured. The former involves 'certifying' the system and the latter 'authenticating' it. Previous work into designing and building AMS systems have focused more on the questions of certifiability than on the questions of authentication - although a few approaches have been investigated. The next step is to build a 3rd generation AMS which (1) makes the appropriate measurements, (2) can be certified, and (3) can be authenticated (the three generations). This paper will discuss the ideas, options, and process of producing a design for a 3rd generation AMS.

  19. Authentication Assurance Level Application to the Inventory Sampling Measurement System

    Devaney, Mike M.; Kouzes, Richard T.; Hansen, Randy R.; Geelhood, Bruce D.


    This document concentrates on the identification of a standardized assessment approach for the verification of security functionality in specific equipment, the Inspection Sampling Measurement System (ISMS) being developed for MAYAK. Specifically, an Authentication Assurance Level 3 is proposed to be reached in authenticating the ISMS.

  20. 43 CFR 12.915 - Metric system of measurement.


    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Metric system of measurement. 12.915 Section 12.915 Public Lands: Interior Office of the Secretary of the Interior ADMINISTRATIVE AND AUDIT REQUIREMENTS AND COST PRINCIPLES FOR ASSISTANCE PROGRAMS Uniform Administrative Requirements for Grants...

  1. Measurement of Spray Drift with a Specifically Designed Lidar System.

    Gregorio, Eduard; Torrent, Xavier; Planas de Martí, Santiago; Solanelles, Francesc; Sanz, Ricardo; Rocadenbosch, Francesc; Masip, Joan; Ribes-Dasi, Manel; Rosell-Polo, Joan R


    Field measurements of spray drift are usually carried out by passive collectors and tracers. However, these methods are labour- and time-intensive and only provide point- and time-integrated measurements. Unlike these methods, the light detection and ranging (lidar) technique allows real-time measurements, obtaining information with temporal and spatial resolution. Recently, the authors have developed the first eye-safe lidar system specifically designed for spray drift monitoring. This prototype is based on a 1534 nm erbium-doped glass laser and an 80 mm diameter telescope, has scanning capability, and is easily transportable. This paper presents the results of the first experimental campaign carried out with this instrument. High coefficients of determination (R² > 0.85) were observed by comparing lidar measurements of the spray drift with those obtained by horizontal collectors. Furthermore, the lidar system allowed an assessment of the drift reduction potential (DRP) when comparing low-drift nozzles with standard ones, resulting in a DRP of 57% (preliminary result) for the tested nozzles. The lidar system was also used for monitoring the evolution of the spray flux over the canopy and to generate 2-D images of these plumes. The developed instrument is an advantageous alternative to passive collectors and opens the possibility of new methods for field measurement of spray drift.

  2. Sustainable Development Indicators in Poland: Measurement and System Evaluation

    Maria Urbaniec


    Full Text Available The aim of this article is to explore the strategic foundations related to the sustainable development measurement and to evaluate the current system of indicators for sustainable development monitoring in Poland. A review of mainstream literature on Sustainable Development Indicators (SDIs was conducted along with document-based descriptive analysis of secondary data and further critical literature analysis. Statistical databases have been used for the analysis. This research paper draws on several strands within the economic, social, environmental, as well as the institutional and political dimensions of sustainability measurement. The results indicate that Polish monitoring system of sustainable development is based on numerous strategic documents. There is no integrated strategy of sustainable development in Poland. The findings also suggest SDI structure has been dominated by social indicators. The evaluation of the Polish measurement system can help to find solutions that support change processes aimed at improving the implementation of sustainable development principles in policy making. This article contributes to existing literature on measurement and monitoring of sustainable development by applying SDIs in the public statistics as well as in the practices of decision making at policy level. Overall, this study extends the understanding of the importance of SDIs and implications of measurement by focusing on the importance of the sustainable development areas.

  3. Detailed Uncertainty Analysis of the ZEM-3 Measurement System

    Mackey, Jon; Sehirlioglu, Alp; Dynys, Fred


    The measurement of Seebeck coefficient and electrical resistivity are critical to the investigation of all thermoelectric systems. Therefore, it stands that the measurement uncertainty must be well understood to report ZT values which are accurate and trustworthy. A detailed uncertainty analysis of the ZEM-3 measurement system has been performed. The uncertainty analysis calculates error in the electrical resistivity measurement as a result of sample geometry tolerance, probe geometry tolerance, statistical error, and multi-meter uncertainty. The uncertainty on Seebeck coefficient includes probe wire correction factors, statistical error, multi-meter uncertainty, and most importantly the cold-finger effect. The cold-finger effect plagues all potentiometric (four-probe) Seebeck measurement systems, as heat parasitically transfers through thermocouple probes. The effect leads to an asymmetric over-estimation of the Seebeck coefficient. A thermal finite element analysis allows for quantification of the phenomenon, and provides an estimate on the uncertainty of the Seebeck coefficient. The thermoelectric power factor has been found to have an uncertainty of +9-14 at high temperature and 9 near room temperature.

  4. A flexible microprocessor system for the measurement of cell size.

    Round, J M; Jones, D A; Edwards, R H


    A flexible system for the measurement of length and area is described. The system consists of the Reichert Jung MOP-1 area measuring device interfaced with a Commodore PET computer. Its use is illustrated by the planimetric measurement of cross sectional areas in histochemical preparations of normal and diseased muscle. While measurements are being made data can be displayed on the computer screen either in numerical form or as a frequency histogram together with simple statistical analyses. Hard copy can be obtained from an attached printer. Mean values for fibre area in normal human skeletal muscle are reported. An alternative, widely used method of calculating fibre area from the lesser diameter was found to give a consistent underestimate of approximately 30% when compared with our planimetric method. In diseased muscle with abnormally shaped fibres the discrepancy is even larger; such fibres can be identified using a "form factor" which relates the area of a cell to its perimeter. This rapid, accurate and flexible system is also suitable for the measurement of many different types of graphical record.

  5. Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems

    Reitz, Sven; Schneider, Peter


    The goal is the development of a novel principle for the temperature acquisition of refrigerants in CO2 air conditioning systems. The new approach is based on measuring the temperature inside a pressure sensor, which is also needed in the system. On the basis of simulative investigations of different mounting conditions functional relations between measured and medium temperature will be derived.

  6. An Orbiting Standards Platform for communication satellite system RF measurements

    Wallace, R. G.; Woodruff, J. J.


    The Orbiting Standards Platform (OSP) is a proposed satellite dedicated to performing RF measurements on space communications systems. It would consist of a quasi-geostationary spacecraft containing an ensemble of calibrated RF sources and field strength meters operating in several microwave bands, and would be capable of accurately and conveniently measuring critical earth station and satellite RF performance parameters, such as EIRP, gain, figure of merit (G/T), crosspolarization, beamwidth, and sidelobe levels. The feasibility and utility of the OSP concept has been under joint study by NASA, NBS, Comsat and NTIA. A survey of potential OSP users was conducted by NTIA as part of this effort. The response to this survey, along with certain trends in satellite communications system design, indicates a growing need for such a measurement service.

  7. Directional pattern measurement of the BRAMS beacon antenna system

    Martínez Picar, A.; Marqué, C.; Anciaux, M.; Lamy, H.


    The typical methods for measuring antenna characteristics are mostly based on the use of remote transmitters or receivers. For antennas used in radio communications, calibrations are usually done on an antenna test stand using transmitters with known power output. In order to minimize the ground effects while performing measurements, it is necessary to place the transmitter or receiver high above ground with the aid of aircrafts. It is, however, necessary to determine precisely the coordinates of the airborne devices as well as to maintain high stability. This used to be excessively difficult to carry out, but recent advances in Unmanned Aerial Vehicle (UAV) technologies have brought a feasible option. In this paper, the results of using a low-cost system for measuring the directional pattern of BRAMS beacon antenna system based on an UAV are presented.

  8. Global positioning system: a new opportunity in physical activity measurement.

    Maddison, Ralph; Ni Mhurchu, Cliona


    Accurate measurement of physical activity is a pre-requisite to monitor population physical activity levels and design effective interventions. Global Positioning System (GPS) technology offers potential to improve the measurement of physical activity. This paper 1) reviews the extant literature on the application of GPS to monitor human movement, with a particular emphasis on free-living physical activity, 2) discusses issues associated with GPS use, and 3) provides recommendations for future research. Overall findings show that GPS is a useful tool to augment our understanding of physical activity by providing the context (location) of the activity and used together with Geographical Information Systems can provide some insight into how people interact with the environment. However, no studies have shown that GPS alone is a reliable and valid measure of physical activity.

  9. A digital coincidence measurement system using FPGA techniques

    Zhu Fengming; Hsieh, S.C.; Yen, W.W. [Department of Engineering and System Science, National Tsing Hua University, Hsinchu, 30043, Taiwan (China); Chou, H.P., E-mail: [Department of Engineering and System Science, National Tsing Hua University, Hsinchu, 30043, Taiwan (China)


    A field programmable gate array (FPGA) based digital coincidence system has been developed to use with NaI scintillators for field applications. The analog output signal from the photomultiplier anode is directly transferred into digital signals by pulse height for pulse width conversion. The digital signal contains the energy and timing information of the radiation events. The pulse width is then measured by a vernier type of time-to-digital converter (TDC). The timing information of radiation events is recorded and analyzed by a coincidence unit. Both the TDC unit and the coincidence unit are implemented using a commercial available FPGA board. The measured data is then sent to a personal computer for spectrum display. Efficiency as well as energy calibration has been performed. The system showed a timing resolution about 13 ns and an energy resolution of 12% for 0.511 MeV annihilation gammas; it also successfully demonstrated the background rejection ability through coincidence measurement.

  10. System, method, and apparatus for remote measurement of terrestrial biomass

    Johnson, Patrick W


    A system, method, and/or apparatus for remote measurement of terrestrial biomass contained in vegetative elements, such as large tree boles or trunks present in an area of interest, are provided. The method includes providing an airborne VHF radar system in combination with a LiDAR system, overflying the area of interest while directing energy toward the area of interest, using the VHF radar system to collect backscatter data from the trees as a function of incidence angle and frequency, and determining a magnitude of the biomass from the backscatter data and data from the laser radar system for each radar resolution cell. A biomass map is generated showing the magnitude of the biomass of the vegetative elements as a function of location on the map by using each resolution cell as a unique location thereon. In certain preferred embodiments, a single frequency is used with a linear array antenna.

  11. Embedded DAQ System Design for Temperature and Humidity Measurement

    Tarique Rafique Memon


    Full Text Available In this work, we have proposed a cost effective DAQ (Data Acquisition system design useful for local industries by using user friendly LABVIEW (Laboratory Virtual Instrumentation Electronic Workbench. The proposed system can measure and control different industrial parameters which can be presented in graphical icon format. The system design is proposed for 8-channels, whereas tested and recorded for two parameters i.e. temperature and RH (Relative Humidity. Both parameters are set as per upper and lower limits and controlled using relays. Embedded system is developed using standard microcontroller to acquire and process the analog data and plug-in for further processing using serial interface with PC using LABVIEW. The designed system is capable of monitoring and recording the corresponding linkage between temperature and humidity in industrial unit's and indicates the abnormalities within the process and control those abnormalities through relays

  12. Non-Contact Conductivity Measurement for Automated Sample Processing Systems

    Beegle, Luther W.; Kirby, James P.


    A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

  13. Impact of plasma noise on a direct thrust measurement system

    Pottinger, S. J.; Lamprou, D.; Knoll, A. K.; Lappas, V. J.


    In order to evaluate the accuracy and sensitivity of a pendulum-type thrust measurement system, a linear variable differential transformer (LVDT) and a laser optical displacement sensor have been used simultaneously to determine the displacement resulting from an applied thrust. The LVDT sensor uses an analog interface, whereas the laser sensor uses a digital interface to communicate the displacement readings to the data acquisition equipment. The data collected by both sensors show good agreement for static mass calibrations and validation with a cold gas thruster. However, the data obtained using the LVDT deviate significantly from that of the laser sensor when operating two varieties of plasma thrusters: a radio frequency (RF) driven plasma thruster, and a DC powered plasma thruster. Results establish that even with appropriate shielding and signal filtering the LVDT sensor is subject to plasma noise and radio frequency interactions which result in anomalous thrust readings. Experimental data show that the thrust determined using the LVDT system in a direct current plasma environment and a RF discharge is approximately a factor of three higher than the thrust values obtained using a laser sensor system for the operating conditions investigated. These findings are of significance to the electric propulsion community as LVDT sensors are often utilized in thrust measurement systems and accurate thrust measurement and the reproducibility of thrust data is key to analyzing thruster performance. Methods are proposed to evaluate system susceptibility to plasma noise and an effective filtering scheme presented for DC discharges.

  14. Gamma-ray scatter methods applied to industrial measurement systems

    Holstad, Marie Bueie


    Throughout the work presented in this dissertation it has been confirmed that the use of scattered gamma-radiation is a complex but useful tool in industrial measurement science. Scattered radiation has shown to be useful both when traditional measurement principles cannot be used (Chapter 4) and when more information about a system is needed than what is obtained with transmission measurements (Chapter 6). All three main projects (Chapters 4, 5 and 6) confirm that the sensitivity and accuracy of systems based on scattered gamma-radiation depends strongly on the geometry of the setup and that that presence of multiple scattered radiation makes the problems complex. Chapter 4 shows that multiple scattered gamma-radiation can be used for detection of changes in density where the dimensions are too large to use transmitted radiation. There is, however, an upper limit on the thickness of the absorbing medium also when scattered radiation is utilized. As seen in Chapter 5, multiple scattered gamma-radiation can in principle also be used in level gauges with very compact measurement geometries. The main challenges are the sensitivity to interfaces between materials with similar densities and low count rate. These challenges could not be overcome for level measurements in gravitational separator tanks. The results presented in Chapter 6 show that it is feasible to combine transmission and scatter measurements to characterize produced water in the oil and gas industry. (Author)

  15. A Framework of Performance Measurement System for Manufacturing Company

    Dermawan Wibisono


    Full Text Available In the current dynamic environment, measuring a company’s performance becomes exceedingly complex since Performance Measurements Systems (PMS not only measure a company’s performance but also reflect their organizational culture and philosophy. Designing and implementing PMS is an integral part of management control systems. However, traditional PMS are criticized for being obsolete, irrelevant to managerial decision making, unrelated to strategic objectives and detrimental to organizational improvements. Given the shortcomings of traditional PMS, there is need for a new framework that can lead to the design of a PMS that balances short-term and long-term measures, internal and external measures, and financial and operational measures. This paper presents issues associated with the needs of a dynamic PMS, observe past research achievements in PMS and review past PMS frameworks that have been introduced. The paper then proposes an improved methodology for the design of a realistic PMS and its effective implementation in a manufacturing environment with case for Indonesia’s company.

  16. Integrated three-dimensional shape and reflection properties measurement system.

    Krzesłowski, Jakub; Sitnik, Robert; Maczkowski, Grzegorz


    Creating accurate three-dimensional (3D) digitalized models of cultural heritage objects requires that information about surface geometry be integrated with measurements of other material properties like color and reflectance. Up until now, these measurements have been performed in laboratories using manually integrated (subjective) data analyses. We describe an out-of-laboratory bidirectional reflectance distribution function (BRDF) and 3D shape measurement system that implements shape and BRDF measurement in a single setup with BRDF uncertainty evaluation. The setup aligns spatial data with the angular reflectance distribution, yielding a better estimation of the surface's reflective properties by integrating these two modality measurements into one setup using a single detector. This approach provides a better picture of an object's intrinsic material features, which in turn produces a higher-quality digitalized model reconstruction. Furthermore, this system simplifies the data processing by combining structured light projection and photometric stereo. The results of our method of data analysis describe the diffusive and specular attributes corresponding to every measured geometric point and can be used to render intricate 3D models in an arbitrarily illuminated scene.

  17. Statistical analysis of complex systems with nonclassical invariant measures

    Fratalocchi, Andrea


    I investigate the problem of finding a statistical description of a complex many-body system whose invariant measure cannot be constructed stemming from classical thermodynamics ensembles. By taking solitons as a reference system and by employing a general formalism based on the Ablowitz-Kaup-Newell-Segur scheme, I demonstrate how to build an invariant measure and, within a one-dimensional phase space, how to develop a suitable thermodynamics. A detailed example is provided with a universal model of wave propagation, with reference to a transparent potential sustaining gray solitons. The system shows a rich thermodynamic scenario, with a free-energy landscape supporting phase transitions and controllable emergent properties. I finally discuss the origin of such behavior, trying to identify common denominators in the area of complex dynamics.

  18. A concise quantum efficiency measurement system for gaseous photomultipliers

    Moriya, Toru [Department of Physics, Yamagata University, Yamagata 990-8560 (Japan); Tokanai, Fuyuki, E-mail: [Department of Physics, Yamagata University, Yamagata 990-8560 (Japan); Okazaki, Keisuke; Sakurai, Hirohisa; Gunji, Shuichi [Department of Physics, Yamagata University, Yamagata 990-8560 (Japan); Kawabata, Hironobu; Sohtome, Takayuki [BUNKOUKEIKI Co., Ltd., Hachioji, Tokyo 192-0033 (Japan); Sumiyoshi, Takayuki [Graduate School of the Faculty of Science and Engineering, Tokyo Metropolitan University, Tokyo 192-0397 (Japan); Sugiyama, Hirioyuki; Okada, Teruyuki; Ohishi, Noboru [Electron Tube Division, Hamamatsu Photonics K.K., Shizuoka 438-0193 (Japan); Kishimoto, Syunji [Institute of Material Structure Science, KEK, Tsukuba 305-0801 (Japan)


    We have been developing gaseous photomultiplier tubes (PMTs) with a bialkali photocathode combined with micropattern gas detectors (MPGDs). The sensitivity of a PMT is described in terms of its quantum efficiency (QE). The QE is very important in many experiments, particularly when dealing with low photon statistics. A concise QE measurement system has been developed to evaluate the characteristics of a sealed gaseous PMT with a bialkali photocathode. This QE measurement system consists of a Xe arc lamp source, reflective optics and filters, a monochromator, and a reference Si photodiode detector. Using the system, we evaluated the QE, gain, and long-term stability of the gaseous PMT. Here, we report the results of our evaluation.

  19. The measurement procedure in the SEMONT monitoring system.

    Djuric, Nikola; Kljajic, Dragan; Kasas-Lazetic, Karolina; Bajovic, Vera


    The measurement procedure of the open area in situ electric field strength is presented, acquiring the real field data for testing of the Serbian electromagnetic field monitoring network (SEMONT) and its Internet portal. The SEMONT monitoring system introduces an advanced approach of wireless sensor network utilization for the continuous supervision of overall and cumulative level of electromagnetic field over the observed area. The aim of the SEMONT system is to become a useful tool for the national and municipal agencies for the environmental protection, regarding the electromagnetic pollution monitoring and the exposure assessment of the general population. Considering the public concern on the potentially harmful effects of the long-term exposure to electromagnetic radiation, as well as the public transparency principle that is incorporated into the Serbian law on non-ionizing radiation protection, the SEMONT monitoring system is designed for the long-term continuous monitoring, presenting real-time measurement results, and corresponding exposure assessment over the public Internet network.

  20. Study on Measuring System of Casing Machine Based on PLC

    Huiqiang Wang


    Full Text Available According to the technology requirements of measurement for animal casing, in this paper, we use PLC and touch screen as the control core, the electromechanical integration design ideas to research the methods and principles for casing measure, and analyze the mechanical structures and mechanical characteristics of casing machine. As the control core, the programmable logic controller (PLC ensures that the whole control system has high precision, high stability, high reliability during the operation time. Through PLC and touch screen well match with PLC which make the casing machine more convenient to operate the whole system. The configuration software form has a brief and intuitive interface on touch screen which makes it easy to use. The mechanical structure and control system of this casing machine are more stable, more reliable and with high anti-interference ability, and satisfies various requirements for animal casings, easy and convenient to operate.

  1. Water depth measurement using an airborne pulsed neon laser system

    Hoge, F. E.; Swift, R. N.; Frederick, E. B.


    The paper presents the water depth measurement using an airborne pulsed neon laser system. The results of initial base-line field test results of NASA airborne oceanographic lidar in the bathymetry mode are given, with water-truth measurements of depth and beam attenuation coefficients by boat taken at the same time as overflights to aid in determining the system's operational performance. The nadir-angle tests and field-of-view data are presented; this laser bathymetry system is an improvement over prior models in that (1) the surface-to-bottom pulse waveform is digitally recorded on magnetic tape, and (2) wide-swath mapping data may be routinely acquired using a 30 deg full-angle conical scanner.


    Petr Volf


    Full Text Available The article deals with the design of a system for studying kinematics of movement of the vestibular system. Up to now there has not existed a system which would enable to measure the kinematic quantities of movement of the individual parts of the vestibular system within its coordinate system. The proposed system removes these deficiencies by suitable positioning of five gyro-accelerometric units on the helmet. The testing of the system took place under two conditions, during Unilateral Rotation on Barany Chair and Head Impulse Test. During the testing, the system justified its application because the results show that the kinematic quantities of the movement of the left and right labyrinths of the vestibular system differ. The introduced device is mainly intended for application in clinical neurology with the aim to enable the physician to measure all linear and angular accelerations of the vestibular system during medical examinations.

  3. A Framework for Measuring Security as a System Property in Cyberphysical Systems

    Janusz Zalewski


    Full Text Available This paper addresses the challenge of measuring security, understood as a system property, of cyberphysical systems, in the category of similar properties, such as safety and reliability. First, it attempts to define precisely what security, as a system property, really is. Then, an application context is presented, in terms of an attack surface in cyberphysical systems. Contemporary approaches related to the principles of measuring software properties are also discussed, with emphasis on building models. These concepts are illustrated in several case studies, based on previous work of the authors, to conduct experimental security measurements.

  4. The Intelligent Measuring Sub-system in the Computer Integrated and Flexible Laser Processing System


    Based on the computer integrated and flexible laser p rocessing system, we developed an intelligent measuring sub-system. A novel mod el has been built to compensate the deviations of the main frame-structure, and a laser tracker system is applied to calibrate the accuracy of the system. Anal yzing the characteristics of all kind surfaces of automobile outer penal moulds and dies, the surface and border to be measured and processed are classified int o four types. A 2-D adaptive measuring method based ...

  5. Relative optical wavefront measurement in displacement measuring interferometer systems with sub-nm precision

    Meskers, A.J.H.; Voigt, D.; Spronck, J.W.


    Many error sources can affect the accuracy of displacement measuring interferometer systems. In heterodyne interferometry two laser source frequencies constitute the finally detected wavefront. When the wavefronts of these source frequencies are non-ideal and one of them walks off the detector, the

  6. Upgrade of PV Lab and Implementation of Automatic Measurement System : Photovoltaic Monitoring System

    Qureshi, Yasir Karim


    The report is focused on the implementation of a data acquisition system that will be used for measuring different parameters which are needed in solar panel behavior analysis. To accomplish the DAQ system a DAQ board has been designed and implemented. This DAQ board acquires measured climatic parameters that affect the PV module behavior and voltage and current of a PV module. The DAQ board may take measurements of multiple analog and digital signals that come from various sensors including ...

  7. Error analysis for a laser differential confocal radius measurement system.

    Wang, Xu; Qiu, Lirong; Zhao, Weiqian; Xiao, Yang; Wang, Zhongyu


    In order to further improve the measurement accuracy of the laser differential confocal radius measurement system (DCRMS) developed previously, a DCRMS error compensation model is established for the error sources, including laser source offset, test sphere position adjustment offset, test sphere figure, and motion error, based on analyzing the influences of these errors on the measurement accuracy of radius of curvature. Theoretical analyses and experiments indicate that the expanded uncertainty of the DCRMS is reduced to U=0.13  μm+0.9  ppm·R (k=2) through the error compensation model. The error analysis and compensation model established in this study can provide the theoretical foundation for improving the measurement accuracy of the DCRMS.

  8. CARS Temperature and Species Measurements For Air Vehicle Propulsion Systems

    Danehy, Paul M.; Gord, James R.; Grisch, Frederic; Klimenko, Dmitry; Clauss, Walter


    The coherent anti-Stokes Raman spectroscopy (CARS) method has recently been used in the United States and Europe to probe several different types of propulsion systems for air vehicles. At NASA Langley Research Center in the United States, CARS has been used to simultaneously measure temperature and the mole fractions of N2, O2 and H2 in a supersonic combustor, representative of a scramjet engine. At Wright- Patterson Air Force Base in the United States, CARS has been used to simultaneously measure temperature and mole fractions of N2, O2 and CO2, in the exhaust stream of a liquid-fueled, gas-turbine combustor. At ONERA in France and the DLR in Germany researchers have used CARS to measure temperature and species concentrations in cryogenic LOX-H2 rocket combustion chambers. The primary aim of these measurements has been to provide detailed flowfield information for computational fluid dynamics (CFD) code validation.

  9. Investigation of human body potential measured by a non-contact measuring system.

    Ichikawa, Norimitsu


    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body's voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not.

  10. a New Method for Measuring Macroparticulate Systems Applied to Measuring Syneresis of Renneted Milk Gels.

    Maynes, Jonathan R.

    Syneresis is an integral part of cheese manufacture. The rate and extent of syneresis affect the properties of cheese. There are many factors that affect syneresis, but measured results vary because of inaccuracies in measuring techniques. To better control syneresis, an accurate mathematical description must be developed. Current mathematical models describing syneresis are limited because of inherent error in measuring techniques used to develop them. Developing an accurate model requires an accurate way to measure syneresis. The curd becomes a particle in a whey suspension when the coagulum is cut. The most effective technique to measure particle size, without interference, is with light. Approximations to rigorous Maxwellian theory render useable results for a variety of particle sizes. Assumptions of Fraunhofer diffraction theory relate absorption to the cross sectional area of a particle that is much larger than the wavelength of light being used. By applying diffraction theory to the curd-whey system, this researcher designed a new apparatus to permit measurement of large particle systems. The apparatus was tested, and calibrated, with polyacrylic beads. Then the syneresis of curd was measured with this apparatus. The apparatus was designed to measure particles in suspension. Until some syneresis takes place, curd does not satisfy this condition. Theoretical assumptions require a monolayer of scattering centers. The sample container must be thin enough to preclude stacking of the particles. This presents a unique problem with curd. If the coagulum is cut in the sample cell, it adheres to the front and back surfaces and does not synerese. The curd must be coagulated and cut externally and transferred to the sample cell with a large amount of whey. This measurement technique has other limitations that may be overcome with commercially available accessories.

  11. Video-Camera-Based Position-Measuring System

    Lane, John; Immer, Christopher; Brink, Jeffrey; Youngquist, Robert


    A prototype optoelectronic system measures the three-dimensional relative coordinates of objects of interest or of targets affixed to objects of interest in a workspace. The system includes a charge-coupled-device video camera mounted in a known position and orientation in the workspace, a frame grabber, and a personal computer running image-data-processing software. Relative to conventional optical surveying equipment, this system can be built and operated at much lower cost; however, it is less accurate. It is also much easier to operate than are conventional instrumentation systems. In addition, there is no need to establish a coordinate system through cooperative action by a team of surveyors. The system operates in real time at around 30 frames per second (limited mostly by the frame rate of the camera). It continuously tracks targets as long as they remain in the field of the camera. In this respect, it emulates more expensive, elaborate laser tracking equipment that costs of the order of 100 times as much. Unlike laser tracking equipment, this system does not pose a hazard of laser exposure. Images acquired by the camera are digitized and processed to extract all valid targets in the field of view. The three-dimensional coordinates (x, y, and z) of each target are computed from the pixel coordinates of the targets in the images to accuracy of the order of millimeters over distances of the orders of meters. The system was originally intended specifically for real-time position measurement of payload transfers from payload canisters into the payload bay of the Space Shuttle Orbiters (see Figure 1). The system may be easily adapted to other applications that involve similar coordinate-measuring requirements. Examples of such applications include manufacturing, construction, preliminary approximate land surveying, and aerial surveying. For some applications with rectangular symmetry, it is feasible and desirable to attach a target composed of black and white

  12. Calibration of NASA Turbulent Air Motion Measurement System

    Barrick, John D. W.; Ritter, John A.; Watson, Catherine E.; Wynkoop, Mark W.; Quinn, John K.; Norfolk, Daniel R.


    A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.


    Modenov, A; Bulatov, M; Livke, A; Morkin, A; Razinkov, S; Safronov, S; Elmont, T; Langner, D; MacArthur, D; Mayo, D; Smith, M; Luke, S J


    This report describes the software development for the plutonium attribute verification system--AVNG. A brief synopsis of the technical solution for the measurement system is presented. The main tasks for the software development that is underway are formulated. The development tasks are shown in software structural flowcharts, measurement system state diagram and a description of the software. The current status of the AVNG software development is elucidated.

  14. An Air Bearing Rotating Coil Magnetic Measurement System

    Gottschalk, Stephen C; Taylor, David J; Thayer, William


    This paper describes a rotating coil magnetic measurement system supported on air bearings. The design is optimized for measurements of 0.1micron magnetic centerline changes on long, small aperture quadrupoles. Graphite impregnated epoxy resin is used for the coil holder and coil winding forms. Coil holder diameter is 11 mm with a length between supports of 750mm. A pair of coils is used to permit quadrupole bucking during centerline measurements. Coil length is 616mm, inner radius 1.82mm, outer radius 4.74mm. The key features of the mechanical system are simplicity; air bearings for accurate, repeatable measurements without needing warm up time and a vibration isolated stand that uses a steel-topped Newport optical table with air suspension. Coil rotation is achieved by a low noise servo motor controlled by a standalone Ethernet servo board running custom servo software. Coil calibration procedures that correct wire placement errors, tests for mechanical resonances, and other system checks will also be discu...

  15. Measuring the Impact of Information Systems in Malaysia

    Nur Fazidah Elias


    Full Text Available Information Systems researchers have employed a diversity of sometimes inconsistent measures of IS success, seldom explicating the rationale, thereby complicating the choice for future researchers. In response to these and other issues, Gable, Sedera and Chan introduced the IS-Impact measurement model. This model represents “the stream of net benefits from the Information System (IS, to date and anticipated, as perceived by all key-user-groups”. Although the IS-Impact model was rigorously validated in previous research, there is a need to further generalise and validate it in different context. This paper reported the findings of the ISImpact model revalidation study at four state governments in Malaysia with 232 users of a financial system that is currently being used at eleven state governments in Malaysia. Data was analysed following the guidelines for formative measurement validation using SmartPLS. Based on the PLS results, data supported the IS-Impact dimensions and measures thus confirming the validity of the ISImpact model in Malaysia. This indicates that the IS-Impact model is robust and can be used across different context.

  16. Application of Three-dimensional Body Measurement System


    The configuration principles and functions of the non-contact three-dimensional (3D) body measurement system (BMS)developed by the Textile/Clothing Technology Corporation ([TC]2) are described in this paper. The advantages of this new system, compared with traditional contact body measurement instruments ( Martin instruments ) are discussed by selecting 40 female undergraduates of Donghua University as the scan objects. In the experiments both the Martin instruments and [TC]2 BMS were used respectively. According to the data of different position ( Bust Circumference, Full Waist, Full Hips, Bust Height, Front Waist Height and Back Waist Height) obtained from both of the methods we can get the correlation coefficient which is close to 1, indicating that the results of both methods have comparability. Finally some suggestions for the further applications of the non-contact BMS in the apparel development of China are given. Ke ywords : Body measurement, anth ro pormetr y , non- contact 3D body measurement system, apparel industry, made-tomeasure (MTM).

  17. Measurement system analysis of viscometers used for drilling mud characterization

    Mat-Shayuti, M. S.; Adzhar, S. N.


    Viscometers in the Faculty of Chemical Engineering, University Teknologi MARA, are subject to heavy utilization from the members of the faculty. Due to doubts surrounding their result integrity and maintenance management, Measurement System Analysis was executed. 5 samples of drilling muds with varied barite content from 5 - 25 weight% were prepared and their rheological properties determined in 3 trials by 3 operators using the viscometers. Gage Linearity and Bias Study were performed using Minitab software and the result shows high biases in the range of 19.2% to 38.7%, with non-linear trend along the span of measurements. Gage Repeatability & Reproducibility (Nested) analysis later produces Percent Repeatability & Reproducibility more than 7.7% and Percent Tolerance above 30%. Lastly, good and marginal Distinct Categories output are seen among the results. Despite acceptable performance of the measurement system in Distinct Categories, the poor results in accuracy, linearity, and Percent Repeatability & Reproducibility render the gage generally not capable. Improvement to the measurement system is imminent.

  18. Portable light transmission measuring system for preserved corneas

    Ventura, Liliane; de Jesus, Gabriel Torres; de Oliveira, Gunter Camilo Dablas; Sousa, Sidney JF


    Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively. PMID:16372912

  19. Novel System for Continuous Measurements of Dissolved Gases in Liquids

    Baer, D. S.; Liem, J.; Owano, T. G.; Gupta, M.


    Measurements of dissolved gases in lakes, rivers and oceans may be used to quantify underwater greenhouse gas generation, air-surface exchange, and pollution migration. Studies involving quantification of dissolved gases typically require obtaining water samples (from streams, lakes, or ocean water) and transporting them to a laboratory, where they are degased. The gases obtained are then generally measured using gas chromatography and isotope ratio mass spectrometry for concentrations and isotope ratios, respectively. This conventional, off-line, discrete-sample methodology is time consuming and labor intensive, and thus severely inhibits detailed spatial and temporal mapping of dissolved gases. In this work, we describe the commercial development of a new portable membrane-based gas extraction system (18.75" x 18.88" x 10.69", 16 kg, 85 watts) that interfaces directly to our cavity enhanced laser absorption based (or Off-Axis ICOS) gas analyzers to continuously and quickly measure concentrations and isotope ratios of dissolved gases. By accurately controlling the water flow rate through the membrane contactor, gas pressure on the outside and water pressure on the inside of the membrane, the system can generate precise and highly reproducible results. Furthermore, the gas-phase mole fractions (parts per million, ppm) may be converted into dissolved gas concentrations (nM), by accurately measuring the gas flow rates in and out of the extraction system. We will present detailed laboratory test data that quantifies the performance (linearity, precision, and dynamic range) of the system for measurements of the concentrations and isotope ratios of dissolved greenhouse gases (methane, carbon dioxide, and nitrous oxide) continuously and in real time.

  20. Evaluation of an attributive measurement system in the automotive industry

    Simion, C.


    Measurement System Analysis (MSA) is a critical component for any quality improvement process. MSA is defined as an experimental and mathematical method of determining how much the variation within the measurement process contributes to overall process variability and it falls into two categories: attribute and variable. Most problematic measurement system issues come from measuring attribute data, which are usually the result of human judgment (visual inspection). Because attributive measurement systems are often used in some manufacturing processes, their assessment is important to obtain the confidence in the inspection process, to see where are the problems in order to eliminate them and to guide the process improvement. It was the aim of this paper to address such a issue presenting a case study made in a local company from the Sibiu region supplying products for the automotive industry, specifically the bag (a technical textile component, i.e. the fabric) for the airbag module. Because defects are inherent in every manufacturing process and in the field of airbag systems a minor defect can influence their performance and lives depend on the safety feature, there is a stringent visual inspection required on the defects of the bag material. The purpose of this attribute MSA was: to determine if all inspectors use the same criteria to determine “pass” from “fail” product (i.e. the fabric); to assess company inspection standards against customer's requirements; to determine how well inspectors are conforming to themselves; to identify how inspectors are conforming to a “known master,” which includes: how often operators ship defective product, how often operators dispose of acceptable product; to discover areas where training is required, procedures must be developed and standards are not available. The results were analyzed using MINITAB software with its module called Attribute Agreement Analysis. The conclusion was that the inspection process must

  1. A Generalized Spatial Measure for Resilience of Microbial Systems

    Renslow, Ryan S.; Lindemann, Stephen R.; Song, Hyun-Seob


    The emergent property of resilience is the ability of a system to return to an original state after a disturbance. Resilience may be used as an early warning system for significant or irreversible community transition, i.e., a community with diminishing or low resilience may be close to catastrophic shift in function or an irreversible collapse. Typically, resilience is quantified using recovery time, which may be difficult or impossible to directly measure in microbial systems. A recent study in the literature showed that under certain conditions, a set of spatial-based metrics termed recovery length, can be correlated to recovery time, and thus may be a reasonable alternative measure of resilience. As a limitation, however, this spatial metric of resilience is useful only for step-change perturbations. Building upon the concept of recovery length, we propose a more general form of the spatial metric of resilience that can be applied to any shape of perturbation profiles (i.e., a sharp or smooth gradient). We termed this new spatial measure “perturbation-adjusted spatial metric of resilience” (PASMORE). We demonstrate the applicability of the proposed metric using a mathematical model of a microbial mat. PASMORE can help identify when a system, such as a microbial community, is on the verge of collapse or nearing an irreversible transition across a tipping point.

  2. A new method for flow measurement in cryogenic systems

    Grohmann, S.


    A new method for mass flow measurement of fluids in pipes is presented; its novelty lies in the capability for intrinsic calibration. The method is founded on a concept, where two independent analytic expressions for the flow rate are formed from the same direct measurement readings (input parameters). If the input parameters were error-free, the two expressions would yield identical results, by definition. This fact can be used as goal function in a minimization routine that removes systematic errors of the inherently error-prone input parameters. The uncertainty of the mass flow measurement is then only influenced by statistical effects and is typically less than 1% with regard to the measured value. The new method is explained by a proof-of-principle that is based on measurements in a large-scale cryogenic system. The intrinsic calibrations can be executed in situ at any moment during operation of a plant, and with no need for a reference standard. While the new method is applicable in any system involving single-phase fluid flow, it offers particular advantages in cryogenic application.

  3. Technological measures of protection in the copyright system

    Radovanović Sanja


    Full Text Available Digital exploitation of works often exceed the limit to which the holder can control the exploitation of their intellectual creations, and the protection provided by legal norms are, in the era of a fast exchange of information, may prove to be insufficiently effective. For these reasons, the rights holders are increasingly opting for preventive care through placement of physical obstacles to the exploitation of copyright works, generic called technological protection measures (known as digital right management (DRM. Simultaneously with the development of the application of these measures flows the process of finding ways to circumvent them. Therefore, the effectiveness of technological measures depends on exactly the question of their legal protection, which now exists in most of modern legal systems. However, in the normative solutions there are differences, which reflect the problems in finding adequate forms of protection. They mostly stem from the fact that the sanctioning of circumvention (or preparatory actions of technological measures put into the question the purpose of copyright protection in general. Hence, in this paper we tried to point out the normative solutions accepted in modern legal systems and practical implications of what they have. Conclusion that arises is that the legal shaping of technological measures is not completed and that further technological developments open new dilemmas.

  4. Simultaneous perimeter measurement for 3D object with a binocular stereo vision measurement system

    Peng, Zhao; Guo-Qiang, Ni


    A simultaneous measurement scheme for multiple three-dimensional (3D) objects' surface boundary perimeters is proposed. This scheme consists of three steps. First, a binocular stereo vision measurement system with two CCD cameras is devised to obtain the two images of the detected objects' 3D surface boundaries. Second, two geodesic active contours are applied to converge to the objects' contour edges simultaneously in the two CCD images to perform the stereo matching. Finally, the multiple spatial contours are reconstructed using the cubic B-spline curve interpolation. The true contour length of every spatial contour is computed as the true boundary perimeter of every 3D object. An experiment on the bent surface's perimeter measurement for the four 3D objects indicates that this scheme's measurement repetition error decreases to 0.7 mm.

  5. Optical fiber sensors measurement system and special fibers improvement

    Jelinek, Michal; Hrabina, Jan; Hola, Miroslava; Hucl, Vaclav; Cizek, Martin; Rerucha, Simon; Lazar, Josef; Mikel, Bretislav


    We present method for the improvement of the measurement accuracy in the optical frequency spectra measurements based on tunable optical filters. The optical filter was used during the design and realization of the measurement system for the inspection of the fiber Bragg gratings. The system incorporates a reference block for the compensation of environmental influences, an interferometric verification subsystem and a PC - based control software implemented in LabView. The preliminary experimental verification of the measurement principle and the measurement system functionality were carried out on a testing rig with a specially prepared concrete console in the UJV Řež. The presented system is the laboratory version of the special nuclear power plant containment shape deformation measurement system which was installed in the power plant Temelin during last year. On the base of this research we started with preparation other optical fiber sensors to nuclear power plants measurement. These sensors will be based on the microstructured and polarization maintaining optical fibers. We started with development of new methods and techniques of the splicing and shaping optical fibers. We are able to made optical tapers from ultra-short called adiabatic with length around 400 um up to long tapers with length up to 6 millimeters. We developed new techniques of splicing standard Single Mode (SM) and Multimode (MM) optical fibers and splicing of optical fibers with different diameters in the wavelength range from 532 to 1550 nm. Together with development these techniques we prepared other techniques to splicing and shaping special optical fibers like as Polarization-Maintaining (PM) or hollow core Photonic Crystal Fiber (PCF) and theirs cross splicing methods with focus to minimalize backreflection and attenuation. The splicing special optical fibers especially PCF fibers with standard telecommunication and other SM fibers can be done by our developed techniques. Adjustment

  6. Measuring chromatic aberrations in imaging systems using plasmonic nanoparticles

    Gennaro, Sylvain D.; Roschuk, Tyler R.; Maier, Stefan A.; Oulton, Rupert F.


    Chromatic aberration in optical systems arises from the wavelength dependence of a glass's refractive index. Polychromatic rays incident upon an optical surface are refracted at slightly different angles and in traversing an optical system follow distinct paths creating images displaced according to color. Although arising from dispersion, it manifests as a spatial distortion correctable only with compound lenses with multiple glasses and accumulates in complicated imaging systems. While chromatic aberration is measured with interferometry, simple methods are attractive for their ease of use and low cost. In this letter we retrieve the longitudinal chromatic focal shift of high numerical aperture (NA) microscope objectives from the extinction spectra of metallic nanoparticles within the focal plane. The method is accurate for high NA objectives with apochromatic correction, and enables rapid assessment of the chromatic aberration of any complete microscopy systems, since it is straightforward to implement

  7. Integrated measure and control system for textile machinery

    Liu, Yuantao; Zhao, Jinzhi; Zhao, Zexiang


    In this paper, textile mechanical drive control is researched. Textile machinery integrated measure and control system is established. The system is composed of micro-computer, PLC, transducer, implement device, all kinds of detective components and industrial Ethernet etc. Technology of industrial field bus control and Internet technique are applied. The system is on a background of textile production technique, such as spring, woven, chemical fiber, non-woven, dyeing and finishing. A network based open integrated control system is developed. Various characteristics of production technique flow and textile machinery movement discipline are presented. Configuration software is introduced according to user's control tasks. Final remote automatic controls are finished. This may make development cost reduced, and development periods shortened. Some problems in textile machinery development process are solved, which may make transparency factory and remote development realized.

  8. Measuring reflective-band imaging systems for performance prediction

    Slonopas, Andre; Preece, Bradley L.; Haefner, David P.


    An objective performance of the reflective-band imaging systems is required in order to provide the warfighter with the right technology for a specific task. Various methods to measure and model performance in the visible (Vis) spectral regions have been proposed in the literature. This correspondence shows the influence of the spectral region averaging on the monochromatic modulation transfer function (MTF). This works unequivocally shows that the illumination source plays a crucial role in the accurate predictive analysis of the system performance. For accurate analysis the illumination sources need to be carefully considered for the atmospheric conditions. This work shows the possibility of using an LED configuration in the system performance analysis. Such configurations need rigorous calibration in order to become a valuable asset in system characterization.

  9. Dielectric properties measurement system at cryogenic temperatures and microwave frequencies

    Molla, J.; Ibarra, A.; Margineda, J.; Zamarro, J. M.; Hernandez, A.


    A system based on the resonant cavity method has been developed to measure the permittivity and loss tangent at 12-18 GHz over the temperature range 80 K to 300 K. Changes of permittivity as low as 0.01 % in the range 1 to 30, and 3 x 10{sup 6} for loss tangent values below 10{sup 2}, can be obtained without requiring temperature stability. The thermal expansion coefficient and resistivity factor of copper have been measured between 80 K and 300 K. Permittivity of sapphire and loss tangent of alumina of 99.9 % purity in the same temperature range are presented. (Author) 23 refs.

  10. Vision system for measuring wagon buffers’ lateral movements

    Barjaktarović Marko


    Full Text Available This paper presents a vision system designed for measuring horizontal and vertical displacements of a railway wagon body. The model comprises a commercial webcam and a cooperative target of an appropriate shape. The lateral buffer movement is determined by calculating target displacement in real time by processing the camera image in a LabVIEW platform using free OpenCV library. Laboratory experiments demonstrate an accuracy which is better than ±0.5 mm within a 50 mm measuring range.

  11. Custom modular electromagnetic induction system for shallow electrical conductivity measurements

    Mester, Achim; Zimmermann, Egon; Tan, Xihe; von Hebel, Christian; van der Kruk, Jan; van Waasen, Stefan


    Electromagnetic induction (EMI) is a contactless measurement method that offers fast and easy investigations of the shallow electrical conductivity, e.g. on the field-scale. Available frequency domain EMI systems offer multiple fixed transmitter-receiver (Tx-Rx) pairs with Tx-Rx separations between 0.3 and 4.0 m and investigation depths of up to six meters. Here, we present our custom EMI system that consists of modular sensor units that can either be transmitters or receivers, and a backpack containing the data acquisition system. The prototype system is optimized for frequencies between 5 and 30 kHz and Tx-Rx separations between 0.4 and 2.0 m. Each Tx and Rx signal is digitized separately and stored on a notebook computer. The soil conductivity information is determined after the measurements with advanced digital processing of the data using optimized correction and calibration procedures. The system stores the raw data throughout the entire procedure, which offers many advantages: (1) comprehensive accuracy and error analysis as well as the reproducibility of corrections and calibration procedures; (2) easy customizability of the number of Tx-/Rx-units and their arrangement and frequencies; (3) signals from simultaneously working transmitters can be separated within the received data using orthogonal signals, resulting in additional Tx-Rx pairs and maximized soil information; and (4) later improvements in the post-processing algorithms can be applied to old data sets. Exemplary, here we present an innovative setup with two transmitters and five receivers using orthogonal signals yielding ten Tx-Rx pairs. Note that orthogonal signals enable for redundant Tx-Rx pairs that are useful for verification of the transmitter signals and for data stacking. In contrast to commercial systems, only adjustments in the post-processing were necessary to realize such measurement configurations with flexibly combined Tx and Rx modules. The presented system reaches an accuracy of

  12. Error Ellipsoid Analysis for the Diameter Measurement of Cylindroid Components Using a Laser Radar Measurement System.

    Du, Zhengchun; Wu, Zhaoyong; Yang, Jianguo


    The use of three-dimensional (3D) data in the industrial measurement field is becoming increasingly popular because of the rapid development of laser scanning techniques based on the time-of-flight principle. However, the accuracy and uncertainty of these types of measurement methods are seldom investigated. In this study, a mathematical uncertainty evaluation model for the diameter measurement of standard cylindroid components has been proposed and applied to a 3D laser radar measurement system (LRMS). First, a single-point error ellipsoid analysis for the LRMS was established. An error ellipsoid model and algorithm for diameter measurement of cylindroid components was then proposed based on the single-point error ellipsoid. Finally, four experiments were conducted using the LRMS to measure the diameter of a standard cylinder in the laboratory. The experimental results of the uncertainty evaluation consistently matched well with the predictions. The proposed uncertainty evaluation model for cylindrical diameters can provide a reliable method for actual measurements and support further accuracy improvement of the LRMS.

  13. Dosimetric measurements and comparison studies in digital imaging system

    Jung, Ji-Young; Kim, Hee-Joung; Lee, Chang-Lae; Cho, Hyo-Min; Nam, Sora


    Number of radiologic exams using digital imaging systems has rapidly increased with advanced imaging technologies. However, it has not been paid attention to the radiation dose in clinical situations. It was the motivation to study radiation dosimetry in the DR system. The objective of this study was to measure beam quality and patient's dose using DR system and to compare them to both IEC standard and IAEA guidelines. The measured average dose for chest and abdomen was 1.376 mGy and 9.501 mGy, respectively, compared to 0.4 mGy and 10.0 mGy in IAEA guidelines. The results also indicated that the DR system has a lower radiation beam quality than that of the IEC standard. The results showed that the patients may be exposed higher radiation for chest exams and lower radiation for abdomen exams using DR system. IAEA Guidelines were prepared based on western people which may be different weight and height for patients compared them to Korean. In conclusion, a new guideline for acceptable DR dosimetry for Korean patients may need to be developed with further studies for large populations. We believe that this research greatly help to introduce the importance of the dosimetry in diagnostic radiology in Korea. And, a development of database for dosimetry in diagnostic radiology will become an opportunity of making aware of radiation safety of medical examination to patient.

  14. Universal digital strain gauge measurement system of aeroelastic deformation development

    Pavlov Anton


    Full Text Available This article presents description of the universal digital strain gauge system developed to measure the static and dynamic aeroelastic deformations of elasticity-scale models during the tests in aerodynamic tube and during in-flight tests of an experimental air vehicles. The main requirements for such devices are small size and possibility of operation in a wide temperature range. The article considers the dependence of zero offset from temperature. Functional diagram block and logic diagram of the build system are shown.

  15. Vibration intensity. Evaluation of a remote measuring system

    Carniel, Xavier


    Two differential laser vibrometers are compared to more classic vibration measuring instruments. A prototype differential laser vibrometer produced by the Centre Technique des Industries Mechaniques (CETIM) and the Photonetics company is tested. A system made up of two Polytec vibrometers is also tested. The Polytec vibrometer is the most accurate. It is a compact tool and uses fiber optic technology which allows positioning of the receptor heads at two neighboring points at the surface of the liquid studied. This type of differential laser vibrometer is shown to give better results than any inductor capacitor or ultrasound system.

  16. A magnetic suspension system for measuring liquid density

    Luz María Centeno González


    Full Text Available Density is a derived quantity of mass and length; it is defined as mass per volume unit and its SI unit is kg/m3. National metrology institutes have been designing and building their own magnetic suspension systems during the last 5 decades for making fluid density measurements; this has allowed them to carry out research into liquids and gases’ physical characteristics. This paper was aimed at designing and developing a magnetic suspension system for a magnetic balance used in determining liquid density to be used in CENAM’s metrology density laboratories.

  17. Indoor Inter-Robot Distance Measurement in Collaborative Systems

    FILOTE, C.


    Full Text Available This paper focuses on the problem of autonomous distance calculation between multiple mobile robots in collaborative systems. We propose and discuss two distinct methods, specifically developed under important design and functional constraints, such as the speed of operation, accuracy, energy and cost efficiency. Moreover, the methods are designed to be applied to indoor robotic systems and are independent of fixed landmarks. The measurement results, performed on the CORE-TX case study, show that the proposed solutions meet the design requirements previously specified.

  18. Research on cloud-based remote measurement and analysis system

    Gao, Zhiqiang; He, Lingsong; Su, Wei; Wang, Can; Zhang, Changfan


    The promising potential of cloud computing and its convergence with technologies such as cloud storage, cloud push, mobile computing allows for creation and delivery of newer type of cloud service. Combined with the thought of cloud computing, this paper presents a cloud-based remote measurement and analysis system. This system mainly consists of three parts: signal acquisition client, web server deployed on the cloud service, and remote client. This system is a special website developed using and Flex RIA technology, which solves the selective contradiction between two monitoring modes, B/S and C/S. This platform supplies customer condition monitoring and data analysis service by Internet, which was deployed on the cloud server. Signal acquisition device is responsible for data (sensor data, audio, video, etc.) collection and pushes the monitoring data to the cloud storage database regularly. Data acquisition equipment in this system is only conditioned with the function of data collection and network function such as smartphone and smart sensor. This system's scale can adjust dynamically according to the amount of applications and users, so it won't cause waste of resources. As a representative case study, we developed a prototype system based on Ali cloud service using the rotor test rig as the research object. Experimental results demonstrate that the proposed system architecture is feasible.

  19. Measuring logic complexity can guide pattern discovery in empirical systems

    Gherardi, Marco


    We explore a definition of complexity based on logic functions, which are widely used as compact descriptions of rules in diverse fields of contemporary science. Detailed numerical analysis shows that (i) logic complexity is effective in discriminating between classes of functions commonly employed in modelling contexts; (ii) it extends the notion of canalisation, used in the study of genetic regulation, to a more general and detailed measure; (iii) it is tightly linked to the resilience of a function's output to noise affecting its inputs. We demonstrate its utility by measuring it in empirical data on gene regulation, digital circuitry, and propositional calculus. Logic complexity is exceptionally low in these systems. The asymmetry between "on" and "off" states in the data correlates with the complexity in a non-null way; a model of random Boolean networks clarifies this trend and indicates a common hierarchical architecture in the three systems.

  20. Development of standard ionization chamber counting system for activity measurements

    Pyun, W B; Lee, H Y; Park, T S


    This study is to set up the activity measuring system using a 4 pi gamma ionization chamber as used mainly in national standards laboratories that are responsible for radionuclide metrology. The software for automatic control between the electrometer and personal computer is developed using Microsoft visual basic 4.0 and IEEE488 Interface. The reproducibility of this 4 pi gamma ionization chamber is about 0.02% and the background current is 0.054+-0.024 pA. this 4 pi gamma ionization chamber is calibrated by 6 standard gamma emitting radionuclides from KRISS. According to the result of this study, it is revealed that this 4 pi gamma ionization chamber counting system can be used as a secondary standard instrument for radioactivity measurement.

  1. Measuring the Aharonov-Anandan phase in multiport photonic systems.

    Wang, Kai; Weimann, Steffen; Nolte, Stefan; Perez-Leija, Armando; Szameit, Alexander


    Beyond the adiabatic limit, the Aharonov-Anandan phase is a generalized description of Berry's phase. In this regime, systems with time-independent Hamiltonians may also acquire observable geometric phases. Here we report on a measurement of the Aharonov-Anandan phase in photonics. Different from previous optical experiments on geometric phases, the implementation is based on light modes confined in evanescently coupled waveguides rather than polarization-like systems, thereby physical models in more than two-dimensional Hilbert spaces are achievable. In a tailored photonic lattice, we realize time-independent quantum-driven harmonic oscillators initially prepared in the vacuum state and achieve a measurement of the Aharonov-Anandan phase via integrated interferometry.

  2. Relating Standardized Visual Perception Measures to Simulator Visual System Performance

    Kaiser, Mary K.; Sweet, Barbara T.


    Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

  3. Change of measure in the lookdown particle system

    Hénard, Olivier


    We perform various changes of measure in the lookdown particle system of Donnelly and Kurtz. The first example is a product type h-transform related to conditioning a Generalized Fleming Viot process without mutation on coexistence of some genetic types in remote time. We give a pathwise construction of this h-transform by just "forgetting" some reproduction events in the lookdown particle system. We also provide an intertwining relationship for the Wright Fisher diffusion and explicit the associated pathwise decomposition. The second example, called the linear or additive h-transform, concerns a wider class of measure valued processes with spatial motion. Applications include: -a simple description of the additive h-transform of the Generalized Fleming Viot process, which confirms a suggestion of Overbeck for the usual Fleming Viot process -an immortal particle representation for the additive h-transform of the Dawson Watanabe process.

  4. Systems of elements preserving measure on varieties of groups

    Timoshenko, E I [Novosibirsk State Technical University, Novosibirsk (Russian Federation)


    It is proved that for any l, 1≤l≤r, a system of elements (v{sub 1},…,v{sub l}) of a free metabelian group S of rank r≥2 is primitive if and only if it preserves measure on the variety of metabelian groups A{sup 2}. From this we obtain the result that a system of elements (v{sub 1},…,v{sub l}) is primitive in the group S if and only if it is primitive in its profinite completion S-hat . Furthermore, it is proved that there exist a variety M and a nonprimitive element v∈F{sub r}(M) such that v preserves measure on M. Bibliography: 13 titles.

  5. System for improving measurement accuracy of transducer by measuring transducer temperature and resistance change using thermoelectric voltages

    Anderson, Karl F. (Inventor); Parker, Allen R., Jr. (Inventor)


    A constant current loop measuring system measures a property including the temperature of a sensor responsive to an external condition being measured. The measuring system includes thermocouple conductors connected to the sensor, sensing first and second induced voltages responsive to the external condition. In addition, the measuring system includes a current generator and reverser generating a constant current, and supplying the constant current to the thermocouple conductors in forward and reverse directions generating first and second measured voltages, and a determining unit receiving the first and second measured voltages from the current generator and reverser, and determining the temperature of the sensor responsive to the first and second measured voltages.

  6. System Identification using Measurements Subject to Stochastic Time Jitter


    When the sensors readings are perturbed by an unknown stochastic time jitter, classical system identification algorithms based on additive amplitude perturbations will give biased estimates. We here outline the maximum likelihood procedure, for the case of both time and amplitude noise, in the frequency domain, based on the measurement DFT. The method directly applies to output error continuous time models, while a simple sinusoid in noise example is used to illustrate the bias removal of the...

  7. Computer Simulation of Angle-measuring System of Photoelectric Theodolite

    Zeng, L [School of Electric Engineering and Automation, HIT, Harbin, 150080 (China); Zhao, Z W [Institute of Command and Technology of Equipment, Beijing, 101416 (China); Song, S L [Institute of Command and Technology of Equipment, Beijing, 101416 (China); Wang, L T [Unit 92941, PLA Huludao, Liaoning, 125000 (China)


    In this paper, a virtual test platform based on malfunction phenomena is designed, using the methods of computer simulation and numerical mask. It is used in the simulation training of angle-measuring system of photoelectric theodolite. Actual application proves that this platform supplies good condition for technicians making deep simulation training and presents a useful approach for the establishment of other large equipment simulation platforms.

  8. System Measures Errors Between Time-Code Signals

    Cree, David; Venkatesh, C. N.


    System measures timing errors between signals produced by three asynchronous time-code generators. Errors between 1-second clock pulses resolved to 2 microseconds. Basic principle of computation of timing errors as follows: central processing unit in microcontroller constantly monitors time data received from time-code generators for changes in 1-second time-code intervals. In response to any such change, microprocessor buffers count of 16-bit internal timer.

  9. Longitudinal evaluation of patient-reported outcomes measurement information systems measures in pediatric chronic pain.

    Kashikar-Zuck, Susmita; Carle, Adam; Barnett, Kimberly; Goldschneider, Kenneth R; Sherry, David D; Mara, Constance A; Cunningham, Natoshia; Farrell, Jennifer; Tress, Jenna; DeWitt, Esi Morgan


    The Patient-Reported Outcomes Measurement Information System (PROMIS) initiative is a comprehensive strategy by the National Institutes of Health to support the development and validation of precise instruments to assess self-reported health domains across healthy and disease-specific populations. Much progress has been made in instrument development, but there remains a gap in the validation of PROMIS measures for pediatric chronic pain. The purpose of this study was to investigate the construct validity and responsiveness to change of 7 PROMIS domains for the assessment of children (ages: 8-18) with chronic pain--Pain Interference, Fatigue, Anxiety, Depression, Mobility, Upper Extremity Function, and Peer Relationships. The PROMIS measures were administered at the initial visit and 2 follow-up visits at an outpatient chronic pain clinic (CPC; N = 82) and at an intensive amplified musculoskeletal pain day-treatment program (N = 63). Aim 1 examined construct validity of PROMIS measures by comparing them with corresponding "legacy" measures administered as part of usual care in the CPC sample. Aim 2 examined sensitivity to change in both CPC and amplified musculoskeletal pain samples. Longitudinal growth models showed that PROMIS' Pain Interference, Anxiety, Depression, Mobility, Upper Extremity, and Peer Relationship measures and legacy instruments generally performed similarly with slightly steeper slopes of improvement in legacy measures. All 7 PROMIS domains showed responsiveness to change. Results offered initial support for the validity of PROMIS measures in pediatric chronic pain. Further validation with larger and more diverse pediatric pain samples and additional legacy measures would broaden the scope of use of PROMIS in clinical research.

  10. Real-time control of sewer systems using turbidity measurements.

    Lacour, C; Schütze, M


    Real-time control (RTC) of urban drainage systems has been proven useful as a means to reduce pollution by combined sewer overflow discharges. So far, RTC has been investigated mainly with a sole focus on water quantity aspects. However, as measurement techniques for pollution of wastewater are advancing, pollution-based RTC might be of increasing interest. For example, turbidity data sets from an extensive measurement programme in two Paris catchments allow a detailed investigation of the benefits of using pollution-based data for RTC. This paper exemplifies this, comparing pollution-based RTC with flow-based RTC. Results suggest that pollution-based RTC indeed has some potential, particularly when measurements of water-quality characteristics are readily available.

  11. Digital measurement system for the LHC klystron high voltage modulator.

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  12. Measurements of Beam Ion Loss from the Compact Helical System

    D. S. Darrow, M. Isobe, Takashi Kondo, M. Sasao, and the CHS Group National Institute for Fusion Science, Toki, Gifu, Japan


    Beam ion loss from the Compact Helical System (CHS) has been measured with a scintillator-type probe. The total loss to the probe, and the pitch angle and gyroradius distributions of that loss, have been measured as various plasma parameters were scanned. Three classes of beam ion loss were observed at the probe position: passing ions with pitch angles within 10o of those of transition orbits, ions on transition orbits, and ions on trapped orbits, typically 15o or more from transition orbits. Some orbit calculations in this geometry have been performed in order to understand the characteristics of the loss. Simulation of the detector signal based upon the following of orbits from realistic beam deposition profiles is not able to reproduce the pitch angle distribution of the losses measured. Consequently it is inferred that internal plasma processes, whether magnetohydrodynamic modes, radial electric fields, or plasma turbulence, move previously confined beam ions to transition orbits, resulting in their loss.

  13. The design and implementation of the AVNG measurement system

    Macarthur, Duncan W [Los Alamos National Laboratory; Thron, Jonathan [Los Alamos National Laboratory; Razinkov, Sergey [RFNC-VNIIEF; Livke, Alexander [RFNC-VNIIEF; Kondratov, Sergey [RFNC-VNIIEF


    An attribute measurement system (AMS) measures a number of unclassified attributes of potentially classified material. By displaying these unclassified results only as red or green lights, the AMS protects potentially classified information while still generating confidence in the measurement result. The AVNG that we describe is an AMS built by RFNC-VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass >2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' In this presentation, we will describe the design of the AVNG neutron and gamma detector subsystems, as well as the design of the entire AMS incorporating these detectors. We will also describe the construction of the AVNG and the final design that was demonstrated in June 2009.

  14. A measurement system of magnetism parameters for motion control

    WANG Xiao-ming; HUANG Xu-yan; LEI Tao


    Magnetism parameters vary with the position and the speed of electromagnetic actuator's motion parts. The measurement unit presented in the paper can be applied to get the position and the speed feedback information from the measurement of electromagnetism parameters, and can constitute the untouched feedback sensing unit in the closed-loop motion control, and it adapts to the diversified feedback control of electromagnetic actuator. The digital miniaturization meter, based on MSP430 single chip processor, which can do the multiformance evaluation and improvement, and also the online quality control in production process. Both real-time data graph and data table can be displayed in the meter. The paper presents the system's structure, describes the principle, discusses the working modes, and shows the software flowchart and the measuring results.

  15. Photogrammetric Measurements of CEV Airbag Landing Attenuation Systems

    Barrows, Danny A.; Burner, Alpheus W.; Berry, Felecia C.; Dismond, Harriett R.; Cate, Kenneth H.


    High-speed photogrammetric measurements are being used to assess the impact dynamics of the Orion Crew Exploration Vehicle (CEV) for ground landing contingency upon return to earth. Test articles representative of the Orion capsule are dropped at the NASA Langley Landing and Impact Research (LandIR) Facility onto a sand/clay mixture representative of a dry lakebed from elevations as high as 62 feet (18.9 meters). Two different types of test articles have been evaluated: (1) half-scale metal shell models utilized to establish baseline impact dynamics and soil characterization, and (2) geometric full-scale drop models with shock-absorbing airbags which are being evaluated for their ability to cushion the impact of the Orion CEV with the earth s surface. This paper describes the application of the photogrammetric measurement technique and provides drop model trajectory and impact data that indicate the performance of the photogrammetric measurement system.

  16. 3D shape measurement system developed on mobile platform

    Wu, Zhoujie; Chang, Meng; Shi, Bowen; Zhang, Qican


    Three-dimensional (3-D) shape measurement technology based on structured light has become one hot research field inspired by the increasing requirements. Many methods have been implemented and applied in the industry applications, but most of their equipments are large and complex, cannot be portable. Meanwhile, the popularity of the smart mobile terminals, such as smart phones, provides a platform for the miniaturization and portability of this technology. The measurement system based on phase-shift algorithm and Gray-code pattern under the Android platform on a mobile phone is mainly studied and developed, and it has been encapsulated into a mobile phone application in order to reconstruct 3-D shape data in the employed smart phone easily and quickly. The experimental results of two measured object are given in this paper and demonstrate the application we developed in the mobile platform is effective.

  17. Improved position measurement of nanoelectromechanical systems using cross correlations

    Doiron, C. B.; Trauzettel, B.; Bruder, C.


    We consider position measurements using the cross-correlated output of two tunnel-junction position detectors. Using a fully quantum treatment, we calculate the equation of motion for the density matrix of the coupled detector detector mechanical-oscillator system. After discussing the presence of a bound on the peak-to-background ratio in a position measurement using a single detector, we show how one can use detector cross correlations to overcome this bound. We analyze two different possible experimental realizations of the cross-correlation measurement and show that in both cases, the maximum cross-correlated output is obtained when using twin detectors and applying equal bias to each tunnel junction. Furthermore, we show how the double-detector setup can be exploited to drastically reduce the added displacement noise of the oscillator.

  18. An upgraded interferometer-polarimeter system for broadband fluctuation measurements

    Parke, E., E-mail:; Ding, W. X.; Brower, D. L. [Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, California 90095 (United States); Duff, J. [Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)


    Measuring high-frequency fluctuations (above tearing mode frequencies) is important for diagnosing instabilities and transport phenomena. The Madison Symmetric Torus interferometer-polarimeter system has been upgraded to utilize improved planar-diode mixer technology. The new mixers reduce phase noise and allow more sensitive measurements of fluctuations at high frequency. Typical polarimeter rms phase noise values of 0.05°–0.07° are obtained with 400 kHz bandwidth. The low phase noise enables the resolution of fluctuations up to 250 kHz for polarimetry and 600 kHz for interferometry. The importance of probe beam alignment for polarimetry is also verified; previously reported tolerances of ≤0.1 mm displacement for equilibrium and tearing mode measurements minimize contamination due to spatial misalignment to within acceptable levels for chords near the magnetic axis.

  19. Phasor Measurement Units in the Eastern Danish power system

    Nielsen, Arne Hejde; Pedersen, Knud Ole Helgesen; Jørgensen, Preben


    In the Eastern Danish transmission system four Phasor Measurement Units (PMU’s) are installed at 400 kV and 132 kV voltage level. The PMU’s continuously record voltage and current phasors each 20 ms. Data are stored locally on the PMU’s and are also transferred to a database at Centre for Electric...... because of their self protection. Nysted offshore wind farm was among the wind power units that disconnected from the grid, and PMU data from that event are analyzed. The case illustrates the close relation between voltages, power flows and voltage phase angles over a wide area. The voltage phase angle...... measurements complements the traditional voltage and power flow measurements....

  20. Advanced wavefront measurement and analysis of laser system modeling

    Wolfe, C.R.; Auerback, J.M. [Lawrence Livermore National Lab., CA (United States)


    High spatial resolution measurements of the reflected or transmitted wavefronts of large aperture optical components used in high peak power laser systems is now possible. These measurements are produced by phase shifting interferometry. The wavefront data is in the form of 3-D phase maps that reconstruct the wavefront shape. The emphasis of this work is on the characterization of wavefront features in the mid-spatial wavelength range (from 0.1 to 10.0 mm) and has been accomplished for the first time. Wavefront structure from optical components with spatial wavelengths in this range are of concern because their effects in high peak power laser systems. At high peak power, this phase modulation can convert to large magnitude intensity modulation by non-linear processes. This can lead to optical damage. We have developed software to input the measured phase map data into beam propagation codes in order to model this conversion process. We are analyzing this data to: (1) Characterize the wavefront structure produced by current optical components, (2) Refine our understanding of laser system performance, (3) Develop a database from which future optical component specifications can be derived.

  1. Semantic Analysis of Tag Similarity Measures in Collaborative Tagging Systems

    Cattuto, Ciro; Hotho, Andreas; Stumme, Gerd


    Social bookmarking systems allow users to organise collections of resources on the Web in a collaborative fashion. The increasing popularity of these systems as well as first insights into their emergent semantics have made them relevant to disciplines like knowledge extraction and ontology learning. The problem of devising methods to measure the semantic relatedness between tags and characterizing it semantically is still largely open. Here we analyze three measures of tag relatedness: tag co-occurrence, cosine similarity of co-occurrence distributions, and FolkRank, an adaptation of the PageRank algorithm to folksonomies. Each measure is computed on tags from a large-scale dataset crawled from the social bookmarking system To provide a semantic grounding of our findings, a connection to WordNet (a semantic lexicon for the English language) is established by mapping tags into synonym sets of WordNet, and applying there well-known metrics of semantic similarity. Our results clearly expose differe...

  2. GPS water level measurements for Indonesia's Tsunami Early Warning System

    Schöne, T.; Pandoe, W.; Mudita, I.; Roemer, S.; Illigner, J.; Zech, C.; Galas, R.


    On Boxing Day 2004, a severe tsunami was generated by a strong earthquake in Northern Sumatra causing a large number of casualties. At this time, neither an offshore buoy network was in place to measure tsunami waves, nor a system to disseminate tsunami warnings to local governmental entities. Since then, buoys have been developed by Indonesia and Germany, complemented by NOAA's Deep-ocean Assessment and Reporting of Tsunamis (DART) buoys, and have been moored offshore Sumatra and Java. The suite of sensors for offshore tsunami detection in Indonesia has been advanced by adding GPS technology for water level measurements. The usage of GPS buoys in tsunami warning systems is a relatively new approach. The concept of the German Indonesian Tsunami Early Warning System (GITEWS) (Rudloff et al., 2009) combines GPS technology and ocean bottom pressure (OBP) measurements. Especially for near-field installations where the seismic noise may deteriorate the OBP data, GPS-derived sea level heights provide additional information. The GPS buoy technology is precise enough to detect medium to large tsunamis of amplitudes larger than 10 cm. The analysis presented here suggests that for about 68% of the time, tsunamis larger than 5 cm may be detectable.

  3. A generalized spatial measure for resilience of microbial systems

    Ryan S. Renslow


    Full Text Available The emergent property of resilience is the ability of a system to recover an original function after a disturbance. Resilience may be used as an early warning system for significant or irreversible community transition, i.e., a community with diminishing or low resilience may be close to catastrophic shift in function or an irreversible collapse. Typically, resilience is quantified using recovery time, which may be difficult or impossible to directly measure in microbial systems. A recent study in the literature showed that under certain conditions, a set of spatial-based metrics termed recovery length, can be correlated to recovery time, and thus may be a reasonable alternative measure of resilience. As a limitation, however, this spatial metric of resilience is useful only for step-change perturbations. Building upon the concept of recovery length, we propose a more general form of the spatial metric of resilience that can be applied to any shape of perturbation profiles (i.e., a sharp or smooth gradient. We termed this new spatial measure perturbation-adjusted spatial metric of resilience (PASMORE. We demonstrate the applicability of the proposed metric using a mathematical model of a microbial mat.

  4. Design of the new rigid endoscope distortion measurement system

    Zhai, Xiaohao; Liu, Xiaohua; Liu, Ming; Hui, Mei; Dong, Liquan; Zhao, Yuejin; Wang, Yakun; Li, Yonghui; Zhou, Peng


    Endoscopic imaging quality affects industrial safety and medical security. Rigid endoscope distortion is of great signification as one of optical parameters to evaluate the imaging quality. This paper introduces a new method of rigid endoscope distortion measurement, which is different from the common methods with low accuracy and fussy operation. It contains a Liquid Crystal Display (LCD) to display the target, a CCD to obtain the images with distortion, and a computer to process the images. The LCD is employed instead of common white screen. The autonomous control system of LCD makes it showing the test target designed for distortion, and its parameter is known. LCD control system can change the test target to satisfy the different demand for accuracy, which avoids replacing target frequently. The test system also contains a CCD to acquire images in the exit pupil position of rigid endoscope. Rigid endoscope distortion is regarded as centrosymmetric, and the MATLAB software automatically measures it by processing the images from CCD. The MATLAB software compares target images with that without distortion on LCD and calculates the results. Relative distortion is obtained at different field of view (FOV) radius. The computer plots the curve of relative distortion, abscissa means radius of FOV, ordinate means relative distortion. The industry standard shows that, the distortion at 70% field of view is pointed on the curve, which can be taken as an evaluation standard. This new measuring method achieves advantages of high precision, high degree of intelligence, excellent repeatability and gets calculation results quickly.

  5. Eye-safe lidar system for pesticide spray drift measurement.

    Gregorio, Eduard; Rocadenbosch, Francesc; Sanz, Ricardo; Rosell-Polo, Joan R


    Spray drift is one of the main sources of pesticide contamination. For this reason, an accurate understanding of this phenomenon is necessary in order to limit its effects. Nowadays, spray drift is usually studied by using in situ collectors which only allow time-integrated sampling of specific points of the pesticide clouds. Previous research has demonstrated that the light detection and ranging (lidar) technique can be an alternative for spray drift monitoring. This technique enables remote measurement of pesticide clouds with high temporal and distance resolution. Despite these advantages, the fact that no lidar instrument suitable for such an application is presently available has appreciably limited its practical use. This work presents the first eye-safe lidar system specifically designed for the monitoring of pesticide clouds. Parameter design of this system is carried out via signal-to-noise ratio simulations. The instrument is based on a 3-mJ pulse-energy erbium-doped glass laser, an 80-mm diameter telescope, an APD optoelectronic receiver and optomechanically adjustable components. In first test measurements, the lidar system has been able to measure a topographic target located over 2 km away. The instrument has also been used in spray drift studies, demonstrating its capability to monitor the temporal and distance evolution of several pesticide clouds emitted by air-assisted sprayers at distances between 50 and 100 m.

  6. Online measurement system for the surface inclination of metal workpieces

    Yin, Peng; Sun, Changku; Wang, Peng; Yang, Qian


    The online measurement of the metal surfaces' parameters plays an important role in many industrial fields. Because the surfaces of the machined metal pieces have the characteristics of strong reflection and high possibilities of scattered disturbing irradiation points, this paper designs an online measurement system based on the measurement principles of linear structured light to detect whether the parameters of the machined metal surfaces' height difference and inclination fulfill the compliance requirements, in which the grayscale gravity algorithm is applied to extract the sub-pixel coordinates of the center of laser, the least squares method is employed to fit the data and the Pauta criterion is utilized to remove the spurious points. The repeat accuracy of this system has been tested. The experimental results prove that the precision of inclination is 0.046° RMS under the speed of 40mm/sec, and the precision of height difference is 0.072mm RMS, which meets the design expectations. Hence, this system can be applied to online industrial detection of high speed and high precision.

  7. GPS water level measurements for Indonesia's Tsunami Early Warning System

    T. Schöne


    Full Text Available On Boxing Day 2004, a severe tsunami was generated by a strong earthquake in Northern Sumatra causing a large number of casualties. At this time, neither an offshore buoy network was in place to measure tsunami waves, nor a system to disseminate tsunami warnings to local governmental entities. Since then, buoys have been developed by Indonesia and Germany, complemented by NOAA's Deep-ocean Assessment and Reporting of Tsunamis (DART buoys, and have been moored offshore Sumatra and Java. The suite of sensors for offshore tsunami detection in Indonesia has been advanced by adding GPS technology for water level measurements.

    The usage of GPS buoys in tsunami warning systems is a relatively new approach. The concept of the German Indonesian Tsunami Early Warning System (GITEWS (Rudloff et al., 2009 combines GPS technology and ocean bottom pressure (OBP measurements. Especially for near-field installations where the seismic noise may deteriorate the OBP data, GPS-derived sea level heights provide additional information.

    The GPS buoy technology is precise enough to detect medium to large tsunamis of amplitudes larger than 10 cm. The analysis presented here suggests that for about 68% of the time, tsunamis larger than 5 cm may be detectable.

  8. Advanced Techniques for Power System Identification from Measured Data

    Pierre, John W.; Wies, Richard; Trudnowski, Daniel


    Time-synchronized measurements provide rich information for estimating a power-system's electromechanical modal properties via advanced signal processing. This information is becoming critical for the improved operational reliability of interconnected grids. A given mode's properties are described by its frequency, damping, and shape. Modal frequencies and damping are useful indicators of power-system stress, usually declining with increased load or reduced grid capacity. Mode shape provides critical information for operational control actions. This project investigated many advanced techniques for power system identification from measured data focusing on mode frequency and damping ratio estimation. Investigators from the three universities coordinated their effort with Pacific Northwest National Laboratory (PNNL). Significant progress was made on developing appropriate techniques for system identification with confidence intervals and testing those techniques on field measured data and through simulation. Experimental data from the western area power system was provided by PNNL and Bonneville Power Administration (BPA) for both ambient conditions and for signal injection tests. Three large-scale tests were conducted for the western area in 2005 and 2006. Measured field PMU (Phasor Measurement Unit) data was provided to the three universities. A 19-machine simulation model was enhanced for testing the system identification algorithms. Extensive simulations were run with this model to test the performance of the algorithms. University of Wyoming researchers participated in four primary activities: (1) Block and adaptive processing techniques for mode estimation from ambient signals and probing signals, (2) confidence interval estimation, (3) probing signal design and injection method analysis, and (4) performance assessment and validation from simulated and field measured data. Subspace based methods have been use to improve previous results from block

  9. Study of accurate volume measurement system for plutonium nitrate solution

    Hosoma, T. [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works


    It is important for effective safeguarding of nuclear materials to establish a technique for accurate volume measurement of plutonium nitrate solution in accountancy tank. The volume of the solution can be estimated by two differential pressures between three dip-tubes, in which the air is purged by an compressor. One of the differential pressure corresponds to the density of the solution, and another corresponds to the surface level of the solution in the tank. The measurement of the differential pressure contains many uncertain errors, such as precision of pressure transducer, fluctuation of back-pressure, generation of bubbles at the front of the dip-tubes, non-uniformity of temperature and density of the solution, pressure drop in the dip-tube, and so on. The various excess pressures at the volume measurement are discussed and corrected by a reasonable method. High precision-differential pressure measurement system is developed with a quartz oscillation type transducer which converts a differential pressure to a digital signal. The developed system is used for inspection by the government and IAEA. (M. Suetake)

  10. A wearable system for multi-segment foot kinetics measurement.

    Rouhani, H; Favre, J; Crevoisier, X; Aminian, K


    This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

  11. Making Health System Performance Measurement Useful to Policy Makers: Aligning Strategies, Measurement and Local Health System Accountability in Ontario

    Veillard, Jeremy; Huynh, Tai; Ardal, Sten; Kadandale, Sowmya; Klazinga, Niek S.; Brown, Adalsteinn D.


    This study examined the experience of the Ontario Ministry of Health and Long-Term Care in enhancing its stewardship and performance management role by developing a health system strategy map and a strategy-based scorecard through a process of policy reviews and expert consultations, and linking them to accountability agreements. An evaluation of the implementation and of the effects of the policy intervention has been carried out through direct policy observation over three years, document analysis, interviews with decision-makers and systematic discussion of findings with other authors and external reviewers. Cascading strategies at health and local health system levels were identified, and a core set of health system and local health system performance indicators was selected and incorporated into accountability agreements with the Local Health Integration Networks. despite the persistence of such challenges as measurement limitations and lack of systematic linkage to decision-making processes, these activities helped to strengthen substantially the ministry's performance management function. PMID:21286268

  12. Model incidence measurement using the SAAB Eloptopos system

    Fuijkschot, P. H.

    For measuring the angle of attack of models in the NLR transonic wind tunnel, a SAAB Eloptopos system was acquired. The system consists of two infrared light-emitting diodes mounted fore and aft in the fuselage of the model, two linear array CCD cameras, and special processors. The cameras are mounted on the sidewall of the wind tunnel and have a viewing angle of 60 deg in the vertical direction. Thanks to an individual calibration and a special optimizing algorithm the camera resolution is enhanced to 0.001 deg. At a viewing distance of 1 m the resulting resolution in angle of attack of the model is typically 0.0026 deg. The system is individually calibrated for each model under wind-off conditions, using an extremely accurate gravity-sensing inclinometer as a reference. This procedure ensures the required accuracy of 0.01 deg in angle of attack under wind-on conditions.

  13. Spectral characterization of dielectric materials using terahertz measurement systems

    Seligman, Jeffrey M.

    The performance of modern high frequency components and electronic systems are often limited by the properties of the materials from which they are made. Over the past decade, there has been an increased emphasis on the development of new, high performance dielectrics for use in high frequency systems. The development of these materials requires novel broadband characterization, instrumentation, and extraction techniques, from which models can be formulated. For this project several types of dielectric sheets were characterized at terahertz (THz) frequencies using quasi-optical (free-space) techniques. These measurement systems included a Fourier Transform Spectrometer (FTS, scalar), a Time Domain Spectrometer (TDS, vector), a Scalar Network Analyzer (SNA), and a THz Vector Network Analyzer (VNA). Using these instruments the THz spectral characteristics of dielectric samples were obtained. Polarization based anisotropy was observed in many of the materials measured using vector systems. The TDS was the most informative and flexible instrument for dielectric characterization at THz frequencies. To our knowledge, this is the first such comprehensive study to be performed. Anisotropy effects within materials that do not come into play at microwave frequencies (e.g. ~10 GHz) were found, in many cases, to increase measured losses at THz frequencies by up to an order of magnitude. The frequency dependent properties obtained during the course of this study included loss tangent, permittivity (index of refraction), and dielectric constant. The results were largely consistent between all the different systems and correlated closely to manufacturer specifications over a wide frequency range (325 GHz-1.5 THz). Anisotropic behavior was observed for some of the materials. Non-destructive evaluation and testing (NDE/NDT) techniques were used throughout. A precision test fixture was developed to accomplish these measurements. Time delay, insertion loss, and S-parameters were

  14. [A Digital System for Bioimpedance and Electrical Impedance Tomography Measurement System].

    Chen, Xiaoyan; Gao, Nana; Huang, Huafang


    A digital system for bioimpedance and electrical impedance tomography (EIT) measurement controlled by an ATmega16 microcontroller was constructed in our laboratory. There are eight digital electrodes using AD5933 to measure the impedance of the targets, and the data is transmitted to the computer wirelessly through nRF24L01. The structure of the system, circuit design, system testing, vitro measurements of animals' tissues and electrical impedance tomography are introduced specifically in this paper. The experimental results showed that the system relative error was 0.42%, and the signal noise ratio was 76.3 dB. The system not only can be used to measure the impedance by any two electrodes within the frequency of 1-100 kHz in a sweep scanning, but also can reconstruct the images of EIT. The animal experiments showed that the data was valid and plots were fitting with Cole-Cole theory. The testing verified the feasibility and effectiveness of the system. The images reconstructed of a salt-water tank are satisfactory and match with the actual distribution of the tank. The system improves the effectiveness of the front-end measuring signal and the stability of the system greatly.

  15. Vision System Measures Motions of Robot and External Objects

    Talukder, Ashit; Matthies, Larry


    A prototype of an advanced robotic vision system both (1) measures its own motion with respect to a stationary background and (2) detects other moving objects and estimates their motions, all by use of visual cues. Like some prior robotic and other optoelectronic vision systems, this system is based partly on concepts of optical flow and visual odometry. Whereas prior optoelectronic visual-odometry systems have been limited to frame rates of no more than 1 Hz, a visual-odometry subsystem that is part of this system operates at a frame rate of 60 to 200 Hz, given optical-flow estimates. The overall system operates at an effective frame rate of 12 Hz. Moreover, unlike prior machine-vision systems for detecting motions of external objects, this system need not remain stationary: it can detect such motions while it is moving (even vibrating). The system includes a stereoscopic pair of cameras mounted on a moving robot. The outputs of the cameras are digitized, then processed to extract positions and velocities. The initial image-data-processing functions of this system are the same as those of some prior systems: Stereoscopy is used to compute three-dimensional (3D) positions for all pixels in the camera images. For each pixel of each image, optical flow between successive image frames is used to compute the two-dimensional (2D) apparent relative translational motion of the point transverse to the line of sight of the camera. The challenge in designing this system was to provide for utilization of the 3D information from stereoscopy in conjunction with the 2D information from optical flow to distinguish between motion of the camera pair and motions of external objects, compute the motion of the camera pair in all six degrees of translational and rotational freedom, and robustly estimate the motions of external objects, all in real time. To meet this challenge, the system is designed to perform the following image-data-processing functions: The visual-odometry subsystem

  16. Force measuring optical tweezers system for long time measurements of P pili stability

    Andersson, Magnus; Fällman, Erik; Uhlin, Bernt Eric; Axner, Ove


    A force-measuring optical tweezers instrumentation and long time measurements of the elongation and retraction of bacterial fimbriae from Uropathogenic E. coli (UPEC) under strain are presented. The instrumentation is presented in some detail. Special emphasis is given to measures taken to reduce the influence of noise and drifts in the system and from the surrounding, which makes long term force measurements possible. Individual P pili from UPEC bacteria were used as a biological model system for repetitive unfolding and refolding cycles of bacterial fimbriae under equilibrium conditions. P pili have evolved into a three-dimensional helix-like structure, the PapA rod, that can be successively and significantly elongated and/or unfolded when exposed to external forces. The instrumentation is used for characterization of the force-vs.-elongation response of the PapA rod of individual P pili, with emphasis on the long time stability of the forced unfolding and refolding of the helical structure of the PapA rod. The results show that the PapA rod is capable of withstanding extensive strain, leading to a complete unfolding of the helical structure, repetitive times during the life cycle of a bacterium without any noticeable alteration of the mechanical properties of the P pili. This function is believed to be importance for UPEC bacteria in vivo since it provides a close contact to a host cell (which is an initial step of invasion) despite urine cleaning attempts.

  17. System Energy Assessment (SEA), Defining a Standard Measure of EROI for Energy Businesses as Whole Systems


    A more objective method for measuring the energy needs of businesses, System Energy Assessment (SEA), identifies the natural boundaries of businesses as self-managing net-energy systems, of controlled and self-managing parts. The method is demonstrated using a model Wind Farm case study, and applied to defining a true physical measure of its energy productivity for society (EROI-S), the global ratio of energy produced to energy cost. The traceable needs of business technology are combined wit...

  18. 4D measurement system for automatic location of anatomical structures

    Witkowski, Marcin; Sitnik, Robert; Kujawińska, Małgorzata; Rapp, Walter; Kowalski, Marcin; Haex, Bart; Mooshake, Sven


    Orthopedics and neurosciences are fields of medicine where the analysis of objective movement parameters is extremely important for clinical diagnosis. Moreover, as there are significant differences between static and dynamic parameters, there is a strong need of analyzing the anatomical structures under functional conditions. In clinical gait analysis the benefits of kinematical methods are undoubted. In this paper we present a 4D (3D + time) measurement system capable of automatic location of selected anatomical structures by locating and tracing the structures' position and orientation in time. The presented system is designed to help a general practitioner in diagnosing selected lower limbs' dysfunctions (e.g. knee injuries) and also determine if a patient should be directed for further examination (e.g. x-ray or MRI). The measurement system components are hardware and software. For the hardware part we adapt the laser triangulation method. In this way we can evaluate functional and dynamic movements in a contact-free, non-invasive way, without the use of potentially harmful radiation. Furthermore, opposite to marker-based video-tracking systems, no preparation time is required. The software part consists of a data acquisition module, an image processing and point clouds (point cloud, set of points described by coordinates (x, y, z)) calculation module, a preliminary processing module, a feature-searching module and an external biomechanical module. The paper briefly presents the modules mentioned above with the focus on the feature-searching module. Also we present some measurement and analysis results. These include: parameters maps, landmarks trajectories in time sequence and animation of a simplified model of lower limbs.

  19. An evaluation of the Wyoming gauge system for snowfall measurement

    Yang, D.; Kane, D.L.; Hinzman, L.D.; Goodison, B.E.; Metcalfe, J.R.; Louie, P.Y.T.; Leavesley, G.H.; Emerson, D.G.; Hanson, C.L.


    The Wyoming snow fence (shield) has been widely used with precipitation gauges for snowfall measurement at more than 25 locations in Alaska since the late 1970s. This gauge's measurements have been taken as the reference for correcting wind-induced gauge undercatch of snowfall in Alaska. Recently, this fence (shield) was tested in the World Meteorological Organization Solid Precipitation Measurement Intercomparison Project at four locations in the United States of America and Canada for six winter seasons. At the Intercomparison sites an octagonal vertical Double Fence with a Russian Tretyakov gauge or a Universal Belfort recording gauge was installed and used as the Intercomparison Reference (DFIR) to provide true snowfall amounts for this intercomparison experiment. The intercomparison data collected were compiled at the four sites that represent a variety of climate, terrain, and exposure. On the basis of these data sets the performance of the Wyoming gauge system for snowfall observations was carefully evaluated against the DFIR and snow cover data. The results show that (1) the mean snow catch efficiency of the Wyoming gauge compared with the DFIR is about 80-90%, (2) there exists a close linear relation between the measurements of the two gauge systems and this relation may serve as a transfer function to adjust the Wyoming gauge records to obtain an estimate of the true snowfall amount, (3) catch efficiency of the Wyoming gauge does not change with wind speed and temperature, and (4) Wyoming gauge measurements are generally compatible to the snowpack water equivalent at selected locations in northern Alaska. These results are important to our effort of determining true snowfall amounts in the high latitudes, and they are also useful for regional hydrologic and climatic analyses.

  20. Urban air quality measurements using a sensor-based system

    Ródenas, Mila; Hernández, Daniel; Gómez, Tatiana; López, Ramón; Muñoz, Amalia


    Air pollution levels in urban areas have increased the interest, not only of the scientific community but also of the general public, and both at the regional and at the European level. This interest has run in parallel to the development of miniaturized sensors, which only since very recently are suitable for air quality measurements. Certainly, their small size and price allows them to be used as a network of sensors capable of providing high temporal and spatial frequency measurements to characterize an area or city and with increasing potential, under certain considerations, as a complement of conventional methods. Within the frame of the LIFE PHOTOCITYTEX project (use of photocatalytic textiles to help reducing air pollution), CEAM has developed a system to measure gaseous compounds of importance for urban air quality characterization. This system, which allows an autonomous power supply, uses commercial NO, NO2, O3 and CO2 small sensors and incorporates measurements of temperature and humidity. A first version, using XBee boards (Radiofrequency) for communications has been installed in the urban locations defined by the project (tunnel and school), permitting the long-term air quality characterization of sites in the presence of the textiles. An improved second version of the system which also comprises a sensor for measuring particles and which uses GPRS for communications, has been developed and successfully installed in the city center of Valencia. Data are sent to a central server where they can be accessed by citizens in nearly real time and online and, in general, they can be utilized in the air quality characterization, for decision-making related to decontamination (traffic regulation, photocatalytic materials, etc.), in air quality models or in mobile applications of interest for the citizens. Within this work, temporal trends obtained with this system in different urban locations will be shown, discussing the impact of the characteristics of the

  1. On-road particle number measurements using a portable emission measurement system (PEMS)

    Gallus, Jens; Kirchner, Ulf; Vogt, Rainer; Börensen, Christoph; Benter, Thorsten


    In this study the on-road particle number (PN) performance of a Euro-5 direct-injection (DI) gasoline passenger car was investigated. PN emissions were measured using the prototype of a portable emission measurement system (PEMS). PN PEMS correlations with chassis dynamometer tests show a good agreement with a chassis dynamometer set-up down to emissions in the range of 1·1010 #/km. Parallel on-line soot measurements by a photo acoustic soot sensor (PASS) were applied as independent measurement technique and indicate a good on-road performance for the PN-PEMS. PN-to-soot ratios were 1.3·1012 #/mg, which was comparable for both test cell and on-road measurements. During on-road trips different driving styles as well as different road types were investigated. Comparisons to the world harmonized light-duty test cycle (WLTC) 5.3 and to European field operational test (euroFOT) data indicate the PEMS trips to be representative for normal driving. Driving situations in varying traffic seem to be a major contributor to a high test-to-test variability of PN emissions. However, there is a trend to increasing PN emissions with more severe driving styles. A cold start effect is clearly visible for PN, especially at low ambient temperatures down to 8 °C.

  2. International-Aerial Measuring System (I-AMS) Training Program

    Wasiolek, Piotre T. [National Security Technologies, LLC; Malchor, Russell L. [National Security Technologies, LLC; Maurer, Richard J. [National Security Technologies, LLC; Adams, Henry L. [National Security Technologies, LLC


    Since the Fukushima reactor accident in 2011, there has been an increased interest worldwide in developing national capabilities to rapidly map and assess ground contamination resulting from nuclear reactor accidents. The capability to rapidly measure the size of the contaminated area, determine the activity level, and identify the radionuclides can aid emergency managers and decision makers in providing timely protective action recommendations to the public and first responders. The development of an aerial detection capability requires interagency coordination to assemble the radiation experts, detection system operators, and aviation aircrews to conduct the aerial measurements, analyze and interpret the data, and provide technical assessments. The Office of International Emergency Management and Cooperation (IEMC) at the U.S. Department of Energy, National Nuclear Security Administration (DOE/NNSA) sponsors an International - Aerial Measuring System (I-AMS) training program for partner nations to develop and enhance their response to radiological emergencies. An initial series of courses can be conducted in the host country to assist in developing an aerial detection capability. As the capability develops and expands, additional experience can be gained through advanced courses with the opportunity to conduct aerial missions over a broad range of radiation environments.

  3. A New Method to Calibrate Robot Visual Measurement System

    Yali Wang


    Full Text Available This paper presents a new method to calibrate the robot visual measurement system. In the paper, a laser tracker is used to calibrate the robot twist angles. Each axis of the robot is moved to many positions and the positions measured by the laser tracker fit a plane. The normal vectors of the planes are the directions of the Z axes. According to the definition of the robot kinematics model parameters, the errors of the twist angles can be calculated. The joint angles zero offsets are calibrated by the constraint that the rotation relationship between the world frame and the robot base frame is relatively constant. A planar target with several parallel lines is used to obtain the pose of the camera relative to the planar target by the lines in the target plane and the vanishing line of the plane. The quantum behaved particle swarm optimization (QPSO algorithm is used to calculate the parameters. Experiments are performed and the results show that the accuracy of the robot visual measurement system is improved about 10 times after being calibrated.

  4. Temperature Measurement and Control System for Transtibial Prostheses: Functional Evaluation.

    Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Lee, Tat Hing; Safari, Mohammad Reza


    The accumulation of heat inside the prosthetic socket increases skin temperature and fosters perspiration, which consequently leads to high tissue stress, friction blister, discomfort, unpleasant odor, and decreased prosthesis suspension and use. In the present study, the prototype of a temperature measurement and control (TM&C) system was designed, fabricated, and functionally evaluated in a phantom model of the transtibial prosthetic socket. The TM&C system was comprised of 12 thermistors divided equally into two groups that arranged internal and external to a prosthetic silicone liner. Its control system was programmed to select the required heating or cooling function of a thermal pump to provide thermal equilibrium based on the amount of temperature difference from a defined set temperature, or the amount of difference between the mean temperature recorded by inside and outside thermistors. A thin layer of aluminum was used for thermal conduction between the thermal pump and different sites around the silicone liner. The results showed functionality of the TM&C system for thermoregulation inside the prosthetic socket. However, enhancing the structure of this TM&C system, increasing its thermal power, and decreasing its weight and cost are main priorities before further development.

  5. U. S. Department of Energy Aerial Measuring Systems

    J. J. Lease


    The Aerial Measuring Systems (AMS) is an aerial surveillance system. This system consists of remote sensing equipment to include radiation detectors; multispectral, thermal, radar, and laser scanners; precision cameras; and electronic imaging and still video systems. This equipment, in varying combinations, is mounted in an airplane or helicopter and flown at different heights in specific patterns to gather various types of data. This system is a key element in the US Department of Energy's (DOE) national emergency response assets. The mission of the AMS program is twofold--first, to respond to emergencies involving radioactive materials by conducting aerial surveys to rapidly track and map the contamination that may exist over a large ground area and second, to conduct routinely scheduled, aerial surveys for environmental monitoring and compliance purposes through the use of credible science and technology. The AMS program evolved from an early program, begun by a predecessor to the DOE--the Atomic Energy Commission--to map the radiation that may have existed within and around the terrestrial environments of DOE facilities, which produced, used, or stored radioactive materials.

  6. Photonic systems for high precision radial velocity measurements

    Halverson, Samuel


    I will discuss new instrumentation and techniques designed to maximize the Doppler radial velocity (RV) measurement precision of next generation exoplanet discovery instruments. These systems include a novel wavelength calibration device based on an all-fiber fabry-perot interferometer, a compact and efficient optical fiber image scrambler based on a single high-index ball lens, and a unique optical fiber mode mixer. These systems have been developed specifically to overcome three technological hurdles that have classically hindered high precision RV measurements in both the optical and near-infrared (NIR), namely: lack of available wavelength calibration sources, inadequate decoupling of the spectrograph from variable telescope illumination, and speckle-induced noise due to mode interference in optical fibers. The instrumentation presented here will be applied to the Habitable-zone Planet Finder, a NIR RV instrument designed to detect rocky planets orbiting in the habitable zones of nearby M-dwarfs, and represents a critical technological step towards the detection of potentially habitable Earth-like planets. While primarily focused in the NIR, many of these systems will be adapted to future optical RV instruments as well, such as NASA's new Extreme Precision Doppler Spectrometer for the WIYN telescope.

  7. Introduction of New Motion Measurement Equipment into Virtual Walk System

    Furukawa, Tatsuya; Itoh, Hideaki; Hori, Toshiyuki; Fukumoto, Hisao; Wakuya, Hiroshi; Ohchi, Masashi

    The “Virtual Walk System” has been developed to support rehabilitation therapy in homes. In the system, a user has been able to perform walking-like exercise on a fitness machine called a stepper. In front of the user, a projected image of a vast virtual reality space is generated by 3-dimensional computer graphics (3DCG). The user's movement is measured and the projected image changes just like the user is walking in the virtual space. Viewing the changing image, the user can enjoy the exercise. In this study, we have decomposed the virtual walk system into two modules (the measurement and control module operated by a microcomputer board and the 3DCG module operated by a personal computer) to facilitate rapid development. Then we have introduced two kinds of new equipment, i.e., a bicycle for cycling exercise and a treadmill for walking exercise. We have also developed a treadmill control system by which a user can easily change the walking speed during exercise.

  8. Rotational-resonance distance measurements in multi-spin systems.

    Verhoeven, Aswin; Williamson, Philip T F; Zimmermann, Herbert; Ernst, Matthias; Meier, Beat H


    It is demonstrated that internuclear distances can be evaluated from rotational-resonance (RR) experiments in uniformly (13)C-labelled compounds. The errors in the obtained distances are less than 10% without the need to know any parameters of the spin system except the isotropic chemical shifts of all spins. We describe the multi-spin system with a simple fictitious spin-1/2 model. The influence of the couplings to the passive spins (J and dipolar coupling) is described by an empirical constant offset from the rotational-resonance condition. Using simulated data for a three-spin system, we show that the two-spin model describes the rotational-resonance transfer curves well as long as none of the passive spins is close to a rotational-resonance condition with one of the active spins. The usability of the two-spin model is demonstrated experimentally using a sample of acetylcholine perchlorate with labelling schemes of various levels of complexity. Doubly-, triply-, and fully labelled compounds lead to strongly varying RR polarization-transfer curves but the evaluated distances using the two-spin model are identical within the expected error limits and coincide with the distance from the X-ray structure. Rotational-resonance distance measurements in fully labelled compounds allow, in particular, the measurement of weak couplings in the presence of strong couplings.

  9. Danish landfill gas plants with automatic measuring and regulation system

    Willumsen, H. [Danish Land Development Service (Denmark)


    The first landfill gas plants in the USA were established on large and deep landfills. A number of wells were made and connected to a horizontal suction pipe through which the gas was sucked from the landfill. Most of the gas extraction systems are still constructed that way. However, control and optimising of the gas extraction can be problematic when a great number of drillings are connected to the same suction pipe. Since 1981 the Danish Ministry of Energy has supported selected research and development projects in connection with extraction and utilisation of landfill gas from Danish landfills, including a pilot plant implemented in 1983. In 1985 a EU-financed demonstration plant was established in Viborg, Denmark. In connection with the pilot and EU demonstration plant an automatic measuring and regulation system was developed to secure optimal gas recovery, identical gas quality and furthermore, it has the advantage of remote monitoring and regulation which save operational costs. The automatic measuring and regulation system is in particular well-suited when the landfill is of a relatively low depth and where regulation of the extraction may cause problems embodied in atmospheric air being sucked down in the landfill causing fluctuation of the gas quality and consequently of the gas quantity. (Author)

  10. Perform Thermodynamics Measurements on Fuel Cycle Case Study Systems

    Martin, Leigh R. [Idaho National Lab. (INL), Idaho Falls, ID (United States)


    This document was prepared to meet FCR&D level 3 milestone M3FT-14IN0304022, “Perform Thermodynamics Measurements on Fuel Cycle Case Study Systems.” This work was carried out under the auspices of the Thermodynamics and Kinetics FCR&D work package. This document reports preliminary work in support of determining the thermodynamic parameters for the ALSEP process. The ALSEP process is a mixed extractant system comprised of a cation exchanger 2-ethylhexyl-phosphonic acid mono-2-ethylhexyl ester (HEH[EHP]) and a neutral solvating extractant N,N,N’,N’-tetraoctyldiglycolamide (TODGA). The extractant combination produces complex organic phase chemistry that is challenging for traditional measurement techniques. To neutralize the complexity, temperature dependent solvent extraction experiments were conducted with neat TODGA and scaled down concentrations of the ALSEP formulation to determine the enthalpies of extraction for the two conditions. A full set of thermodynamic data for Eu, Am, and Cm extraction by TODGA from 3.0 M HNO3 is reported. These data are compared to previous extraction results from a 1.0 M HNO3 aqueous medium, and a short discussion of the mixed HEH[EHP]/TODGA system results is offered.

  11. Accurate measurement of RF exposure from emerging wireless communication systems

    Letertre, Thierry; Monebhurrun, Vikass; Toffano, Zeno


    Isotropic broadband probes or spectrum analyzers (SAs) may be used for the measurement of rapidly varying electromagnetic fields generated by emerging wireless communication systems. In this paper this problematic is investigated by comparing the responses measured by two different isotropic broadband probes typically used to perform electric field (E-field) evaluations. The broadband probes are submitted to signals with variable duty cycles (DC) and crest factors (CF) either with or without Orthogonal Frequency Division Multiplexing (OFDM) modulation but with the same root-mean-square (RMS) power. The two probes do not provide accurate enough results for deterministic signals such as Worldwide Interoperability for Microwave Access (WIMAX) or Long Term Evolution (LTE) as well as for non-deterministic signals such as Wireless Fidelity (WiFi). The legacy measurement protocols should be adapted to cope for the emerging wireless communication technologies based on the OFDM modulation scheme. This is not easily achieved except when the statistics of the RF emission are well known. In this case the measurement errors are shown to be systematic and a correction factor or calibration can be applied to obtain a good approximation of the total RMS power.

  12. Conductivity measurements in a shear-banding wormlike micellar system.

    Photinos, Panos J; López-González, M R; Hoven, Corey V; Callaghan, Paul T


    Shear banding in the cetylpyridinium chloride/sodium salicylate micellar system is investigated using electrical conductivity measurements parallel to the velocity and parallel to the vorticity in a cylindrical Couette cell. The measurements show that the conductivity parallel to the velocity (vorticity) increases (decreases) monotonically with applied shear rate. The shear-induced anisotropy is over one order of magnitude lower than the anisotropy of the N(c) nematic phase. The steady-state conductivity measurements indicate that the anisotropy of the shear induced low-viscosity (high shear rate) phase is not significantly larger than the anisotropy of the high viscosity (low shear rate) phase. We estimate that the micelles in the shear induced low viscosity band are relatively short, with a characteristic length to diameter ratio of 5-15. The relaxation behavior following the onset of shear is markedly different above and below the first critical value γ1, in agreement with results obtained by other methods. The transient measurements show that the overall anisotropy of the sample decreases as the steady state is approached, i.e., the micellar length/the degree of order decrease.

  13. GHz measurements of correlated electron systems in high magnetic fields

    Edwards, R S


    This Thesis presents experiments performed on the high-frequency conductivity of materials in high magnetic fields. The angle dependence of resonances measured in the millimetre-wave absorption is studied using a rotating resonant cavity system, and the frequency dependence is measured using transmission techniques and a tuneable resonant cavity. Chapter 1 introduces the materials. These include the crystalline organic metals, the layered superconductor Sr sub 2 RUO sub 4 and the quantum Ising ferromagnet LiHoF sub 4. In Chapters 2 and 3, the necessary physics and experimental techniques for their investigation are outlined. Chapters 4 to 6 present measurements of cyclotron resonance in layered materials. Chapter 4 describes several models for the origin of cyclotron resonance harmonics, and describes the first definite measurement of the harmonics of a cyclotron resonance in an organic molecular metal, namely beta sup - (BEDT-TTF) sub 2 SF sub 5 CH sub 2 CF sub 2 SO sub 3. The angle dependence of the field p...

  14. Cosmic ray detection based measurement systems: a preliminary study

    Bodini, I.; Bonomi, G.; Cambiaghi, D.; Magalini, A.; Zenoni, A.


    Cosmic rays, mostly composed of high energy muons, continuously hit the Earth's surface (at sea level the rate is about 10 000 m-2 min-1). Various technologies are adopted for their detection and are widespread in the field of particle and nuclear physics. In this paper, cosmic ray muon detection techniques are assessed for measurement applications in engineering, where these methods could be suitable for several applications, with specific reference to situations where environmental conditions are weakly controlled and/or where the parts to be measured are hardly accessible. Since cosmic ray showering phenomena show statistical nature, the Monte Carlo technique has been adopted to numerically simulate a particular application, where a set of muon detectors are employed for alignment measurements on an industrial press. An analysis has been performed to estimate the expected measurement uncertainty and system resolution, which result to be strongly dependent on the dimensions and geometry of the set-up, on the presence of materials interposed between detectors and, ultimately, on the elapsed time available for the data taking.

  15. Measure Solar System Objects and Their Movements for Yourself!

    Clark, John D


    Instead of taking somebody's word about the basic size and distances for the solar system's objects, this book shows amateur astronomers how to measure these things for themselves. This is an enriching experience for any amateur astronomer - to understand and personally measure fundamental astronomical quantities and distances. A basic knowledge of geometry is required, but it is amazing how simple the ideas can be. Readers are led through the details as gently as possible - and in a light-hearted way - presuming that most will have half-forgotten most of the mathematics. The practical astronomical equipment recommended is no more than a typical commercially-made amateur telescope and a camera of some sort - these days a webcam works very well. Apart from that all the reader will need is access to a computer with internet service, the know-how to download free software, and an enthusiasm to expand his knowledge of the basics of scientific astronomy.

  16. Movement layout and adjustment for a specialized video measuring system

    Liu, Xinbo; Wang, Zhong; Zhu, Jigui; Zhang, Jin


    Specialized video measuring system (SVMS) is a kind of instruments diagnosing only one special type of part with high performance. In the design of a SVMS, it is necessary to consider the special requirements during the inspection of the parts. We take the video-based inspecting instrument for watch escapement (VIIWE) as an example of SVMS. A method based on least interferences is proposed to determine an optimized movement layout. The quality of image taken by an imaging lens with a limited depth of field (100 μm) may be degraded by two parameters, i.e., the perpendicularity of optical axis to workbench and the parallelism of probe movement plane to workbench. To optimize the two parameters, we calibrate the perpendicularity with a definition function, measure the parallelism with a dial indicator, and develop a mechanism of adjustment. The scheme about movement layout and adjustment has been successfully applied in the VIIWE.

  17. A wideband combined transducer for measuring system in sound tube

    PAN Yaozong; MO Xiping; LIU Yongping; CUI Zheng; ZHANG Tonggen


    A wideband transducer for sound tube system is presented, which combines longitudinal transducer and Class IV flextensional transducer to improve the performance at low frequency and broaden the working band. The equivalent circuit is obtained and used to analyze the coupling mechanism between longitudinal transducer and flextensional transducer. A prototype of the transducer is developed after optimizing the electro-acoustic performances by Finite Element Method. The standing wave in the sound tube stimulated by this transducer has been studied and the sound absorbing coefficients of two acoustic materials samples are measured using this sound tube, which shows that the transducer can meet the requirements of acoustic material measurement with the working band ranging from 1.4 kHz to 23 kHz.

  18. Developing a performance measurement system for public research centres

    Masella, C.


    Full Text Available This study aims at developing a performance measurement system (PMS for research and development (R&D activities carried out by public research centres. Public research institutions are characterized by multiple stakeholders with different needs, and the management of R&D activities requires balancing the multiple goals of different stakeholders. This characteristic is a key issue in the process of construction of the PMS. Empirical evidence is provided by an Italian public research centre, where the researchers carried out a project aimed to develop a PMS following action research principles. This project gave the possibility to researchers to interact with different stakeholders and integrate their different information needs in a comprehensive set of key performance indicators (KPIs. As a result, multidimensional framework for measuring R&D performance in a public research centre is proposed and a set of Key Performance Indicators is developed, suggesting implications for academics and practitioners.

  19. Predicting biological system objectives de novo from internal state measurements

    Maranas Costas D


    Full Text Available Abstract Background Optimization theory has been applied to complex biological systems to interrogate network properties and develop and refine metabolic engineering strategies. For example, methods are emerging to engineer cells to optimally produce byproducts of commercial value, such as bioethanol, as well as molecular compounds for disease therapy. Flux balance analysis (FBA is an optimization framework that aids in this interrogation by generating predictions of optimal flux distributions in cellular networks. Critical features of FBA are the definition of a biologically relevant objective function (e.g., maximizing the rate of synthesis of biomass, a unit of measurement of cellular growth and the subsequent application of linear programming (LP to identify fluxes through a reaction network. Despite the success of FBA, a central remaining challenge is the definition of a network objective with biological meaning. Results We present a novel method called Biological Objective Solution Search (BOSS for the inference of an objective function of a biological system from its underlying network stoichiometry as well as experimentally-measured state variables. Specifically, BOSS identifies a system objective by defining a putative stoichiometric "objective reaction," adding this reaction to the existing set of stoichiometric constraints arising from known interactions within a network, and maximizing the putative objective reaction via LP, all the while minimizing the difference between the resultant in silico flux distribution and available experimental (e.g., isotopomer flux data. This new approach allows for discovery of objectives with previously unknown stoichiometry, thus extending the biological relevance from earlier methods. We verify our approach on the well-characterized central metabolic network of Saccharomyces cerevisiae. Conclusion We illustrate how BOSS offers insight into the functional organization of biochemical networks

  20. Development of the Computerized Model of Performance-Based Measurement System to Measure Nurses' Clinical Competence.

    Liou, Shwu-Ru; Liu, Hsiu-Chen; Tsai, Shu-Ling; Cheng, Ching-Yu; Yu, Wei-Chieh; Chu, Tsui-Ping


    Critical thinking skills and clinical competence are for providing quality patient care. The purpose of this study is to develop the Computerized Model of Performance-Based Measurement system based on the Clinical Reasoning Model. The system can evaluate and identify learning needs for clinical competency and be used as a learning tool to increase clinical competency by using computers. The system includes 10 high-risk, high-volume clinical case scenarios coupled with questions testing clinical reasoning, interpersonal, and technical skills. Questions were sequenced to reflect patients' changing condition and arranged by following the process of collecting and managing information, diagnosing and differentiating urgency of problems, and solving problems. The content validity and known-groups validity was established. The Kuder-Richardson Formula 20 was 0.90 and test-retest reliability was supported (r = 0.78). Nursing educators can use the system to understand students' needs for achieving clinical competence, and therefore, educational plans can be made to better prepare students and facilitate their smooth transition to a future clinical environment. Clinical nurses can use the system to evaluate their performance-based abilities and weakness in clinical reasoning. Appropriate training programs can be designed and implemented to practically promote nurses' clinical competence and quality of patient care.