WorldWideScience

Sample records for rbc membrane stiffness

  1. Neem leaf extract as potential modifier of free radical interaction with RBC membrane

    International Nuclear Information System (INIS)

    Patil, Shilpa M.; Kulkarni, Satish G.; Rane, Charusheela

    2004-01-01

    Full text: Neem tree (Azadirachta indica) is well known as village pharmacy due to its multifaceted medicinal action in curing countless health problems. The leaf extract of Neem is known to purify blood by removing toxins and neutralizing free radicals. Using gamma irradiation as free radical generation process the efficacy of neem leaf extract in combating free radical attack on RBC membrane has been explored. The results narrating role of concentration and dose dependency in this radio modulation will be discussed

  2. Myosin IIA interacts with the spectrin-actin membrane skeleton to control red blood cell membrane curvature and deformability.

    Science.gov (United States)

    Smith, Alyson S; Nowak, Roberta B; Zhou, Sitong; Giannetto, Michael; Gokhin, David S; Papoin, Julien; Ghiran, Ionita C; Blanc, Lionel; Wan, Jiandi; Fowler, Velia M

    2018-05-08

    The biconcave disk shape and deformability of mammalian RBCs rely on the membrane skeleton, a viscoelastic network of short, membrane-associated actin filaments (F-actin) cross-linked by long, flexible spectrin tetramers. Nonmuscle myosin II (NMII) motors exert force on diverse F-actin networks to control cell shapes, but a function for NMII contractility in the 2D spectrin-F-actin network of RBCs has not been tested. Here, we show that RBCs contain membrane skeleton-associated NMIIA puncta, identified as bipolar filaments by superresolution fluorescence microscopy. MgATP disrupts NMIIA association with the membrane skeleton, consistent with NMIIA motor domains binding to membrane skeleton F-actin and contributing to membrane mechanical properties. In addition, the phosphorylation of the RBC NMIIA heavy and light chains in vivo indicates active regulation of NMIIA motor activity and filament assembly, while reduced heavy chain phosphorylation of membrane skeleton-associated NMIIA indicates assembly of stable filaments at the membrane. Treatment of RBCs with blebbistatin, an inhibitor of NMII motor activity, decreases the number of NMIIA filaments associated with the membrane and enhances local, nanoscale membrane oscillations, suggesting decreased membrane tension. Blebbistatin-treated RBCs also exhibit elongated shapes, loss of membrane curvature, and enhanced deformability, indicating a role for NMIIA contractility in promoting membrane stiffness and maintaining RBC biconcave disk cell shape. As structures similar to the RBC membrane skeleton exist in many metazoan cell types, these data demonstrate a general function for NMII in controlling specialized membrane morphology and mechanical properties through contractile interactions with short F-actin in spectrin-F-actin networks.

  3. Calculation of reaction forces in the boiler supports using the method of equivalent stiffness of membrane wall.

    Science.gov (United States)

    Sertić, Josip; Kozak, Dražan; Samardžić, Ivan

    2014-01-01

    The values of reaction forces in the boiler supports are the basis for the dimensioning of bearing steel structure of steam boiler. In this paper, the application of the method of equivalent stiffness of membrane wall is proposed for the calculation of reaction forces. The method of equalizing displacement, as the method of homogenization of membrane wall stiffness, was applied. On the example of "Milano" boiler, using the finite element method, the calculation of reactions in the supports for the real geometry discretized by the shell finite element was made. The second calculation was performed with the assumption of ideal stiffness of membrane walls and the third using the method of equivalent stiffness of membrane wall. In the third case, the membrane walls are approximated by the equivalent orthotropic plate. The approximation of membrane wall stiffness is achieved using the elasticity matrix of equivalent orthotropic plate at the level of finite element. The obtained results were compared, and the advantages of using the method of equivalent stiffness of membrane wall for the calculation of reactions in the boiler supports were emphasized.

  4. Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall

    Directory of Open Access Journals (Sweden)

    Josip Sertić

    2014-01-01

    Full Text Available The values of reaction forces in the boiler supports are the basis for the dimensioning of bearing steel structure of steam boiler. In this paper, the application of the method of equivalent stiffness of membrane wall is proposed for the calculation of reaction forces. The method of equalizing displacement, as the method of homogenization of membrane wall stiffness, was applied. On the example of “Milano” boiler, using the finite element method, the calculation of reactions in the supports for the real geometry discretized by the shell finite element was made. The second calculation was performed with the assumption of ideal stiffness of membrane walls and the third using the method of equivalent stiffness of membrane wall. In the third case, the membrane walls are approximated by the equivalent orthotropic plate. The approximation of membrane wall stiffness is achieved using the elasticity matrix of equivalent orthotropic plate at the level of finite element. The obtained results were compared, and the advantages of using the method of equivalent stiffness of membrane wall for the calculation of reactions in the boiler supports were emphasized.

  5. The effects of membrane cholesterol and simvastatin on red blood cell deformability and ATP release.

    Science.gov (United States)

    Forsyth, Alison M; Braunmüller, Susanne; Wan, Jiandi; Franke, Thomas; Stone, Howard A

    2012-05-01

    It is known that deformation of red blood cells (RBCs) is linked to ATP release from the cells. Further, membrane cholesterol has been shown to alter properties of the cell membrane such as fluidity and bending stiffness. Membrane cholesterol content is increased in some cardiovascular diseases, for example, in individuals with acute coronary syndromes and chronic stable angina, and therefore, because of the potential clinical relevance, we investigated the influence of altered RBC membrane cholesterol levels on ATP release. Because of the correlation between statins and reduced membrane cholesterol in vivo, we also investigated the effects of simvastatin on RBC deformation and ATP release. We found that reducing membrane cholesterol increases cell deformability and ATP release. We also found that simvastatin increases deformability by acting directly on the membrane in the absence of the liver, and that ATP release was increased for cells with enriched cholesterol after treatment with simvastatin. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Use of Laser Assisted Optical Rotational Cell Analyzer (LoRRca MaxSis in the Diagnosis of RBC Membrane Disorders, Enzyme Defects, and Congenital Dyserythropoietic Anemias: A Monocentric Study on 202 Patients

    Directory of Open Access Journals (Sweden)

    Anna Zaninoni

    2018-04-01

    Full Text Available Chronic hemolytic anemias are a group of heterogeneous diseases mainly due to abnormalities of red cell (RBC membrane and metabolism. The more common RBC membrane disorders, classified on the basis of blood smear morphology, are hereditary spherocytosis (HS, elliptocytosis, and hereditary stomatocytoses (HSt. Among RBC enzymopathies, the most frequent is pyruvate kinase (PK deficiency, followed by glucose-6-phosphate isomerase, pyrimidine 5′ nucleotidase P5′N, and other rare enzymes defects. Because of the rarity and heterogeneity of these diseases, diagnosis may be often challenging despite the availability of a variety of laboratory tests. The ektacytometer laser-assisted optical rotational cell analyser (LoRRca MaxSis, able to assess the RBC deformability in osmotic gradient conditions (Osmoscan analysis, is a useful diagnostic tool for RBC membrane disorders and in particular for the identification of hereditary stomatocytosis. Few data are so far available in other hemolytic anemias. We evaluated the diagnostic power of LoRRca MaxSis in a large series of 140 patients affected by RBC membrane disorders, 37 by enzymopathies, and 16 by congenital diserythropoietic anemia type II. Moreover, nine patients with paroxysmal nocturnal hemoglobinuria (PNH were also investigated. All the hereditary spherocytoses, regardless the biochemical defect, showed altered Osmoscan curves, with a decreased Elongation Index (EI max and right shifted Omin; hereditary elliptocytosis (HE displayed a trapezoidal curve and decreased EImax. Dehydrated hereditary stomatocytosis (DHSt caused by PIEZO1 mutations was characterized by left-shifted curve, whereas KCNN4 mutations were associated with a normal curve. Congenital diserythropoietic anemia type II and RBC enzymopathies had Osmoscan curve within the normal range except for glucosephosphate isomerase (GPI deficient cases who displayed an enlarged curve associated with significantly increased Ohyper, offering a

  7. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  8. RBC nuclear scan

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  9. Red blood cell (RBC) membrane proteomics--Part I: Proteomics and RBC physiology.

    Science.gov (United States)

    Pasini, Erica M; Lutz, Hans U; Mann, Matthias; Thomas, Alan W

    2010-01-03

    Membrane proteomics is concerned with accurately and sensitively identifying molecules involved in cell compartmentalisation, including those controlling the interface between the cell and the outside world. The high lipid content of the environment in which these proteins are found often causes a particular set of problems that must be overcome when isolating the required material before effective HPLC-MS approaches can be performed. The membrane is an unusually dynamic cellular structure since it interacts with an ever changing environment. A full understanding of this critical cell component will ultimately require, in addition to proteomics, lipidomics, glycomics, interactomics and study of post-translational modifications. Devoid of nucleus and organelles in mammalian species other than camelids, and constantly in motion in the blood stream, red blood cells (RBCs) are the sole mammalian oxygen transporter. The fact that mature mammalian RBCs have no internal membrane-bound organelles, somewhat simplifies proteomics analysis of the plasma membrane and the fact that it has no nucleus disqualifies microarray based methods. Proteomics has the potential to provide a better understanding of this critical interface, and thereby assist in identifying new approaches to diseases. (c) 2009 Elsevier B.V. All rights reserved.

  10. Stiffness of RBC optical confinement affected by optical clearing

    Science.gov (United States)

    Grishin, Oleg V.; Fedosov, Ivan V.; Tuchin, Valery V.

    2017-03-01

    In vivo optical trapping is a novel applied direction of an optical manipulation, which enables one to noninvasive measurement of mechanical properties of cells and tissues in living animals directly. But an application area of this direction is limited because strong scattering of many biological tissues. An optical clearing enables one to decrease the scattering and therefore increase a depth of light penetration, decrease a distortion of light beam, improve a resolution in imaging applications. Now novel methods had appeared for a measurement an optical clearing degree at a cellular level. But these methods aren't applicable in vivo. In this paper we present novel measurement method of estimate of the optical clearing, which are based on a measurement of optical trap stiffness. Our method may be applicable in vivo.

  11. The effect of a negative capacitance circuit on the out-of-plane dissipation and stiffness of a piezoelectric membrane

    International Nuclear Information System (INIS)

    Korde, Umesh A; Wickersham, Miles A; Carr, Stephen G

    2008-01-01

    This paper investigates the out-of-plane dynamics of a piezoelectric membrane with a negative capacitance circuit connected in parallel. The theoretically possible large changes in stiffness and dissipation could, at full implementation, enable the design of selectively electroded piezoelectric skins that are spatially and temporally highly adaptive. A tunable negative capacitance circuit is here connected in parallel with a polyvinylidene fluoride (PVDF) membrane (Date et al 2000 J. Appl. Phys. 87 863–8). The goal of this paper is to investigate the extent to which such a circuit may influence the out-of-plane stiffness and dissipation characteristics and the associated vibration response of a PVDF membrane strip. We consider strips with a non-vanishing thickness and under a constant boundary-applied tension. As our analytical and experimental results for harmonic loading show, successful application of the method on out-of-plane dynamics is possible with a correct choice of the circuit parameters, and the out-of-plane stiffness and dissipation and the associated vibration response near the first resonance can be altered noticeably by adjusting the circuit settings

  12. Red Blood Cell Membrane-Cloaked Nanoparticles For Drug Delivery

    Science.gov (United States)

    Carpenter, Cody Westcott

    Herein we describe the development of the Red Blood Cell coated nanoparticle, RBC-NP. Purified natural erythrocyte membrane is used to coat drug-loaded poly(lacticco-glycolic acid) (PLGA). Synthetic PLGA co-polymer is biocompatible and biodegradable and has already received US FDA approval for drug-delivery and diagnostics. This work looks specifically at the retention of immunosuppressive proteins on RBC-NPs, right-sidedness of natural RBC membranes interfacing with synthetic polymer nanoparticles, sustained and retarded drug release of RBC-NPs as well as further surface modification of RBC-NPs for increased targeting of model cancer cell lines.

  13. In vivo crossmatching with Tc-99m-RBC's and In-111-oxine-RBC's

    International Nuclear Information System (INIS)

    Marcus, C.S.; Myhre, B.A.; Angulo, M.C.; Salk, R.D.; Essex, C.E.

    1984-01-01

    In vitro crossmatching techniques are often inadequate for patients who have received multiple prior transfusions. These patients usually have multiple antibodies to minor blood groups, not all of which are necessarily important to vivo. It becomes increasingly difficult to obtain appropriate units for transfusion, and often units are used with hopes that a minor group antibody will not be significantly active in vivo. If a transfusion reaction occurs, the unit is stopped. The authors have developed and successfully tested a method whereby 1.5 to 3c of potential donor RBC's are labeled with 25-50 μCi of Tc-99m using the BNL kits. After injection, samples are drawn at 10, 20, 60, and 120 minutes and the RBC survival is measured. If it is desirable to test 2 units simultaneously, the authors use 400 μCi Tc-99m to label an RBC aliquot of one unit and 25 μCi In-111-oxine to label the other; both labeled aliquots are injected together. The method is simple and reliable. In addition to assessing compatibility, the authors may also estimate the % viability of transfused, compatible RBC's by starting with 400 μCi of Tc-99m and multiplying % survival at 24 hours by 1.2. For 24 hr. survival measurements of IN-111-oxine-RBC's, 25 μCi is adequate and no multiplication factor is necessary. The authors have performed 13 in vivo crossmatches, 4 of which were double, in 6 patients. One documented mild transfusion reaction occurred. There were no false positive or false negative results

  14. Derivative expansion of one-loop effective energy of stiff membranes with tension

    Science.gov (United States)

    Borelli, M. E. S.; Kleinert, H.; Schakel, Adriaan M. J.

    1999-03-01

    With help of a derivative expansion, the one-loop corrections to the energy functional of a nearly flat, stiff membrane with tension due to thermal fluctuations are calculated in the Monge parametrization. Contrary to previous studies, an arbitrary tilt of the surface is allowed to exhibit the nontrivial relations between the different, highly nonlinear terms accompanying the ultraviolet divergences. These terms are shown to have precisely the same form as those in the original energy functional, as necessary for renormalizability. Also infrared divergences arise. These, however, are shown to cancel in a nontrivial way.

  15. Studies on RBC lipid and protein phosphorylation during blood bank storage

    International Nuclear Information System (INIS)

    Dumaswala, U.J.; Bryan, D.J.; Greenwalt, T.J.

    1986-01-01

    Recent evidence has suggested that phosphoinositides play a significant role in maintaining membrane structure and function. Their importance during blood bank storage is not understood. They have performed preliminary studies of the phosphoinositide synthetic pathway enzymes of RBC during blood bank storage. At 0 and 35 days of storage leaky ghosts were prepared and incubated with [γ- 32 P]ATP for 5 minutes at 30 C. One aliquot was subjected to acidified solvent extraction and thin layer chromatography. The labeled phosphoinositide -4,5 biphosphate (PIP 2 ), phosphoinositide-4 phosphate (PIP) and phosphatidic acid (PA) spots were scraped and counted by liquid scintillation spectrometry. Another aliquot was used for SDS-PAGE and the radioactivity associated with the β-spectrin was measured. These experiments suggest a decrease in RBC phosphoinositol and PIP-Kinases and β-spectrin kinase activities during blood bank storage. Further studies are being done to evaluate significance of these observations

  16. MPP1 directly interacts with flotillins in erythrocyte membrane - Possible mechanism of raft domain formation.

    Science.gov (United States)

    Biernatowska, Agnieszka; Augoff, Katarzyna; Podkalicka, Joanna; Tabaczar, Sabina; Gajdzik-Nowak, Weronika; Czogalla, Aleksander; Sikorski, Aleksander F

    2017-11-01

    Flotillins are prominent, oligomeric protein components of erythrocyte (RBC) membrane raft domains and are considered to play an important structural role in lateral organization of the plasma membrane. In our previous work on erythroid membranes and giant plasma membrane vesicles (GPMVs) derived from them we have shown that formation of functional domains (resting state rafts) depends on the presence of membrane palmitoylated protein 1 (MPP1/p55), pointing to its new physiological role. Exploration of the molecular mechanism of MPP1 function in organizing membrane domains described here, through searching for its molecular partners in RBC membrane by using different methods, led to the identification of the raft-marker proteins, flotillin 1 and flotillin 2, as hitherto unreported direct MPP1 binding-partners in the RBC membrane. These proteins are found in high molecular-weight complexes in native RBC membrane and, significantly, their presence was shown to be separate from the well-known protein 4.1-dependent interactions of MPP1 with membrane proteins. Furthermore, FLIM analysis revealed that loss of the endogenous MPP1-flotillins interactions resulted in significant changes in RBC membrane-fluidity, emphasizing the physiological importance of such interactions in vivo. Therefore, our data establish a new perspective on the role of MPP1 in erythroid cells and suggests that direct MPP1-flotillins interactions could be the major driving-force behind the formation of raft domains in RBC. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  17. A gene phylogeny of the red algae (Rhodophyta) based on plastid rbcL.

    Science.gov (United States)

    Freshwater, D W; Fredericq, S; Butler, B S; Hommersand, M H; Chase, M W

    1994-01-01

    A phylogeny for the Rhodophyta has been inferred by parsimony analysis of plastid rbcL sequences representing 81 species, 68 genera, 38 families, and 17 orders of red algae; rbcL encodes the large subunit of ribulose-1,5-bisphosphate carboxylase/oxygenase. Levels of sequence divergence among species, genera, and families are high in red algae, typically much greater than those reported for flowering plants. The Rhodophyta traditionally consists of one class, Rhodophyceae, and two subclasses, Bangiophycidae and Florideophycidae. The Bangiophycidae with three orders (Porphyridiales, Compsopogonales, and Bangiales) appears to be polyphyletic, and the Florideophycidae with 17 orders is monophyletic in this study. The current classification of the Florideophycidae based on ultrastructure of pit connections is supported. With the exception of the Rhodogorgonales, which appears to be misplaced, orders with one or two pit-plug cap layers (Hildenbrandiales, Corallinales, Acrochaetiales, Palmanales, Batrachospermales, and Nemaliales) terminate long branches of basal position within Florideophycidae in the most parsimonious rbcL tree. Orders that lack typical cap layers but possess a cap membrane are resolved as a monophyletic clade sister to the Ahnfeltiales. The large order Gigartinales, which is distributed among five rbcL clades, is polyphyletic. Families that possess typical carrageenan in their cell walls are resolved as a terminal clade containing two family complexes centered around the Solieriaceae and Gigartinaceae. PMID:8041781

  18. Investigation of membrane mechanics using spring networks: application to red-blood-cell modelling.

    Science.gov (United States)

    Chen, Mingzhu; Boyle, Fergal J

    2014-10-01

    In recent years a number of red-blood-cell (RBC) models have been proposed using spring networks to represent the RBC membrane. Some results predicted by these models agree well with experimental measurements. However, the suitability of these membrane models has been questioned. The RBC membrane, like a continuum membrane, is mechanically isotropic throughout its surface, but the mechanical properties of a spring network vary on the network surface and change with deformation. In this work spring-network mechanics are investigated in large deformation for the first time via an assessment of the effect of network parameters, i.e. network mesh, spring type and surface constraint. It is found that a spring network is conditionally equivalent to a continuum membrane. In addition, spring networks are employed for RBC modelling to replicate the optical tweezers test. It is found that a spring network is sufficient for modelling the RBC membrane but strain-hardening springs are required. Moreover, the deformation profile of a spring network is presented for the first time via the degree of shear. It is found that spring-network deformation approaches continuous as the mesh density increases. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Transformation of membrane nanosurface of red blood cells under hemin action

    Science.gov (United States)

    Kozlova, Elena; Chernysh, Alexander; Moroz, Victor; Gudkova, Olga; Sergunova, Victoria; Kuzovlev, Artem

    2014-08-01

    Hemin is the product of hemoglobin oxidation. Some diseases may lead to a formation of hemin. The accumulation of hemin causes destruction of red blood cells (RBC) membranes. In this study the process of development of topological defects of RBC membranes within the size range from nanoscale to microscale levels is shown. The formation of the grain-like structures in the membrane (``grains'') with typical sizes of 120-200 nm was experimentally shown. The process of formation of ``grains'' was dependent on the hemin concentration and incubation time. The possible mechanism of membrane nanostructure alterations is proposed. The kinetic equations of formation and transformation of small and medium topological defects were analyzed. This research can be used to study the cell intoxication and analyze the action of various agents on RBC membranes.

  20. RBC micromotors carrying multiple cargos towards potential theranostic applications

    Science.gov (United States)

    Wu, Zhiguang; Esteban-Fernández de Ávila, Berta; Martín, Aída; Christianson, Caleb; Gao, Weiwei; Thamphiwatana, Soracha Kun; Escarpa, Alberto; He, Qiang; Zhang, Liangfang; Wang, Joseph

    2015-08-01

    Red blood cell (RBC)-based micromotors containing both therapeutic and diagnostic modalities are described as a means for potential theranostic applications. In this natural RBC-based multicargo-loaded micromotor system, quantum dots (QDs), anti-cancer drug doxorubicin (DOX), and magnetic nanoparticles (MNPs), were co-encapsulated into RBC micromotors. The fluorescent emission of both QDs and DOX provides direct visualization of their loading inside the RBC motors at two distinct wavelengths. The presence of MNPs within the RBCs allows for efficient magnetic guidance under ultrasound propulsion along with providing the potential for magnetic resonance imaging. The simultaneous encapsulation of the imaging nanoparticles and therapeutic payloads within the same RBC micromotor has a minimal effect upon its propulsion behavior. The ability of the RBC micromotors to transport imaging and therapeutic agents at high speed and spatial precision through a complex microchannel network is also demonstrated. Such ability to load and transport diagnostic imaging agents and therapeutic drugs within a single cell-based motor, in addition to a lower toxicity observed once the drug is encapsulated within the multicargo RBC motor, opens the door to the development of theranostic micromotors that may simultaneously treat and monitor diseases.Red blood cell (RBC)-based micromotors containing both therapeutic and diagnostic modalities are described as a means for potential theranostic applications. In this natural RBC-based multicargo-loaded micromotor system, quantum dots (QDs), anti-cancer drug doxorubicin (DOX), and magnetic nanoparticles (MNPs), were co-encapsulated into RBC micromotors. The fluorescent emission of both QDs and DOX provides direct visualization of their loading inside the RBC motors at two distinct wavelengths. The presence of MNPs within the RBCs allows for efficient magnetic guidance under ultrasound propulsion along with providing the potential for magnetic

  1. Erythrocyte membrane-coated nanogel for combinatorial antivirulence and responsive antimicrobial delivery against Staphylococcus aureus infection.

    Science.gov (United States)

    Zhang, Yue; Zhang, Jianhua; Chen, Wansong; Angsantikul, Pavimol; Spiekermann, Kevin A; Fang, Ronnie H; Gao, Weiwei; Zhang, Liangfang

    2017-10-10

    We reported an erythrocyte membrane-coated nanogel (RBC-nanogel) system with combinatorial antivirulence and responsive antibiotic delivery for the treatment of methicillin-resistant Staphylococcus aureus (MRSA) infection. RBC membrane was coated onto the nanogel via a membrane vesicle templated in situ gelation process, whereas the redox-responsiveness was achieved by using a disulfide bond-based crosslinker. We demonstrated that the RBC-nanogels effectively neutralized MRSA-associated toxins in extracellular environment and the toxin neutralization in turn promoted bacterial uptake by macrophages. In intracellular reducing environment, the RBC-nanogels showed an accelerated drug release profile, which resulted in more effective bacterial inhibition. When added to the macrophages infected with intracellular MRSA bacteria, the RBC-nanogels significantly inhibited bacterial growth compared to free antibiotics and non-responsive nanogel counterparts. These results indicate the great potential of the RBC-nanogel system as a new and effective antimicrobial agent against MRSA infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Red blood cell membrane-camouflaged melanin nanoparticles for enhanced photothermal therapy.

    Science.gov (United States)

    Jiang, Qin; Luo, Zimiao; Men, Yongzhi; Yang, Peng; Peng, Haibao; Guo, Ranran; Tian, Ye; Pang, Zhiqing; Yang, Wuli

    2017-10-01

    Photothermal therapy (PTT) has represented a promising noninvasive approach for cancer treatment in recent years. However, there still remain challenges in developing non-toxic and biodegradable biomaterials with high photothermal efficiency in vivo. Herein, we explored natural melanin nanoparticles extracted from living cuttlefish as effective photothermal agents and developed red blood cell (RBC) membrane-camouflaged melanin (Melanin@RBC) nanoparticles as a platform for in vivo antitumor PTT. The as-obtained natural melanin nanoparticles demonstrated strong absorption at NIR region, higher photothermal conversion efficiency (∼40%) than synthesized melanin-like polydopamine nanoparticles (∼29%), as well as favorable biocompatibility and biodegradability. It was shown that RBC membrane coating on melanin nanoparticles retained their excellent photothermal property, enhanced their blood retention and effectively improved their accumulation at tumor sites. With the guidance of their inherited photoacoustic imaging capability, optimal accumulation of Melanin@RBC at tumors was achieved around 4 h post intravenous injection. Upon irradiation by an 808-nm laser, the developed Melanin@RBC nanoparticles exhibited significantly higher PTT efficacy than that of bare melanin nanoparticles in A549 tumor-bearing mice. Given that both melanin nanoparticles and RBC membrane are native biomaterials, the developed Melanin@RBC platform could have great potential in clinics for anticancer PTT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. RBC micromotors carrying multiple cargos towards potential theranostic applications.

    Science.gov (United States)

    Wu, Zhiguang; Esteban-Fernández de Ávila, Berta; Martín, Aída; Christianson, Caleb; Gao, Weiwei; Thamphiwatana, Soracha Kun; Escarpa, Alberto; He, Qiang; Zhang, Liangfang; Wang, Joseph

    2015-08-28

    Red blood cell (RBC)-based micromotors containing both therapeutic and diagnostic modalities are described as a means for potential theranostic applications. In this natural RBC-based multicargo-loaded micromotor system, quantum dots (QDs), anti-cancer drug doxorubicin (DOX), and magnetic nanoparticles (MNPs), were co-encapsulated into RBC micromotors. The fluorescent emission of both QDs and DOX provides direct visualization of their loading inside the RBC motors at two distinct wavelengths. The presence of MNPs within the RBCs allows for efficient magnetic guidance under ultrasound propulsion along with providing the potential for magnetic resonance imaging. The simultaneous encapsulation of the imaging nanoparticles and therapeutic payloads within the same RBC micromotor has a minimal effect upon its propulsion behavior. The ability of the RBC micromotors to transport imaging and therapeutic agents at high speed and spatial precision through a complex microchannel network is also demonstrated. Such ability to load and transport diagnostic imaging agents and therapeutic drugs within a single cell-based motor, in addition to a lower toxicity observed once the drug is encapsulated within the multicargo RBC motor, opens the door to the development of theranostic micromotors that may simultaneously treat and monitor diseases.

  4. Erythrocyte membrane-coated gold nanocages for targeted photothermal and chemical cancer therapy

    Science.gov (United States)

    Zhu, Dao-Ming; Xie, Wei; Xiao, Yu-Sha; Suo, Meng; Zan, Ming-Hui; Liao, Qing-Quan; Hu, Xue-Jia; Chen, Li-Ben; Chen, Bei; Wu, Wen-Tao; Ji, Li-Wei; Huang, Hui-Ming; Guo, Shi-Shang; Zhao, Xing-Zhong; Liu, Quan-Yan; Liu, Wei

    2018-02-01

    Recently, red blood cell (RBC) membrane-coated nanoparticles have attracted much attention because of their excellent immune escapability; meanwhile, gold nanocages (AuNs) have been extensively used for cancer therapy due to their photothermal effect and drug delivery capability. The combination of the RBC membrane coating and AuNs may provide an effective approach for targeted cancer therapy. However, few reports have shown the utilization of combining these two technologies. Here, we design erythrocyte membrane-coated gold nanocages for targeted photothermal and chemical cancer therapy. First, anti-EpCam antibodies were used to modify the RBC membranes to target 4T1 cancer cells. Second, the antitumor drug paclitaxel (PTX) was encapsulated into AuNs. Then, the AuNs were coated with the modified RBC membranes. These new nanoparticles were termed EpCam-RPAuNs. We characterized the capability of the EpCam-RPAuNs for selective tumor targeting via exposure to near-infrared irradiation. The experimental results demonstrate that EpCam-RPAuNs can effectively generate hyperthermia and precisely deliver the antitumor drug PTX to targeted cells. We also validated the biocompatibility of the EpCam-RAuNs in vitro. By combining the molecularly modified targeting RBC membrane and AuNs, our approach provides a new way to design biomimetic nanoparticles to enhance the surface functionality of nanoparticles. We believe that EpCam-RPAuNs can be potentially applied for cancer diagnoses and therapies.

  5. Physiologic Impact of Circulating RBC Microparticles upon Blood-Vascular Interactions

    Directory of Open Access Journals (Sweden)

    Ahmed S. Said

    2018-01-01

    Full Text Available Here, we review current data elucidating the role of red blood cell derived microparticles (RMPs in normal vascular physiology and disease progression. Microparticles (MPs are submicron-size, membrane-encapsulated vesicles derived from various parent cell types. MPs are produced in response to numerous stimuli that promote a sequence of cytoskeletal and membrane phospholipid changes and resulting MP genesis. MPs were originally considered as potential biomarkers for multiple disease processes and more recently are recognized to have pleiotropic biological effects, most notably in: promotion of coagulation, production and handling of reactive oxygen species, immune modulation, angiogenesis, and in initiating apoptosis. RMPs, specifically, form normally during RBC maturation in response to injury during circulation, and are copiously produced during processing and storage for transfusion. Notably, several factors during RBC storage are known to trigger RMP production, including: increased intracellular calcium, increased potassium leakage, and energy failure with ATP depletion. Of note, RMP composition differs markedly from that of intact RBCs and the nature/composition of RMP components are affected by the specific circumstances of RMP genesis. Described RMP bioactivities include: promotion of coagulation, immune modulation, and promotion of endothelial adhesion as well as influence upon vasoregulation via influence upon nitric oxide (NO bioavailability. Of particular relevance, RMPs scavenge NO more avidly than do intact RBCs; this physiology has been proposed to contribute to the impaired oxygen delivery homeostasis that may be observed following transfusion. In summary, RMPs are submicron particles released from RBCs, with demonstrated vasoactive properties that appear to disturb oxygen delivery homeostasis. The clinical impact of RMPs in normal and patho-physiology and in transfusion recipients is an area of continued investigation.

  6. Evaluation of antioxidant capacity and membrane stabilizing ...

    African Journals Online (AJOL)

    Both the leaf and root of C. adenocaulis were extracted with 70% ethanol to yield the ... ELE and ERE were able to protect red blood cell (RBC) membrane against ... antioxidant, anti-inflammatory, lipid peroxidation, membrane stabilization.

  7. A robust mass spectrometry method for rapid profiling of erythrocyte ghost membrane proteomes.

    Science.gov (United States)

    Fye, Haddy K S; Mrosso, Paul; Bruce, Lesley; Thézénas, Marie-Laëtitia; Davis, Simon; Fischer, Roman; Rwegasira, Gration L; Makani, Julie; Kessler, Benedikt M

    2018-01-01

    Red blood cell (RBC) physiology is directly linked to many human disorders associated with low tissue oxygen levels or anemia including chronic obstructive pulmonary disease, congenital heart disease, sleep apnea and sickle cell anemia. Parasites such as Plasmodium spp. and phylum Apicomplexa directly target RBCs, and surface molecules within the RBC membrane are critical for pathogen interactions. Proteomics of RBC membrane 'ghost' fractions has therefore been of considerable interest, but protocols described to date are either suboptimal or too extensive to be applicable to a larger set of clinical cohorts. Here, we describe an optimised erythrocyte isolation protocol from blood, tested for various storage conditions and explored using different fractionation conditions for isolating ghost RBC membranes. Liquid chromatography mass spectrometry (LC-MS) analysis on a Q-Exactive Orbitrap instrument was used to profile proteins isolated from the comparative conditions. Data analysis was run on the MASCOT and MaxQuant platforms to assess their scope and diversity. The results obtained demonstrate a robust method for membrane enrichment enabling consistent MS based characterisation of > 900 RBC membrane proteins in single LC-MS/MS analyses. Non-detergent based membrane solubilisation methods using the tissue and supernatant fractions of isolated ghost membranes are shown to offer effective haemoglobin removal as well as diverse recovery including erythrocyte membrane proteins of high and low abundance. The methods described in this manuscript propose a medium to high throughput framework for membrane proteome profiling by LC-MS of potential applicability to larger clinical cohorts in a variety of disease contexts.

  8. RBC-choline: changes by lithium and relation to prophylactic response

    International Nuclear Information System (INIS)

    Haag, M.; Haag, H.; Eisenried, F.; Greil, W.

    1984-01-01

    Red blod cell (RBC)- and plasma-choline levels were measured in patients on lithium (n=96), antidepressants (n=32) and neuroleptics (n=51) and in 25 healthy drug-free controls. Lithium patients exhibited highly increased RBC- and slightly increased plasma-choline levels compared with controls (P<0.001 and P<0.05, respectively); the choline ratio (RBC-/plasma-choline) was elevated almost to the same extent as RBC-choline (P<0.001). With antidepressants RBC-choline and choline ratios were slightly reduced (P<0.05), whereas neuroleptics showed no effect on choline levels. 79% of lithium patients were responders (reduction in hospitalizations with lithium) 21% were non-responders (no reduction or increase in hospitalizations). Choline ratio exhibited a significant relation to prophylactic lithium response, but lithium ratio did not. The percentage of non-responders was significantly higher in patients with a choline ratio exceeding 100 than in patients with a choline ratio below this cut-off (P<0.01). Thus, the increase of RBC-choline and choline ratios appears to be an effect specific for lithium and might be related to the outcome of lithium prophylaxis. (author)

  9. Synthetic nanoparticles camouflaged with biomimetic erythrocyte membranes for reduced reticuloendothelial system uptake

    International Nuclear Information System (INIS)

    Rao, Lang; Xu, Jun-Hua; Cai, Bo; Liu, Huiqin; Li, Ming; Jia, Yan; Xiao, Liang; Guo, Shi-Shang; Liu, Wei; Zhao, Xing-Zhong

    2016-01-01

    Suppression of the reticuloendothelial system (RES) uptake is one of the most challenging tasks in nanomedicine. Coating stratagems using polymers, such as poly(ethylene glycol) (PEG), have led to great success in this respect. Nevertheless, recent observations of immunological response toward these synthetic polymers have triggered a search for better alternatives. In this work, natural red blood cell (RBC) membranes are camouflaged on the surface of Fe 3 O 4 nanoparticles for reducing the RES uptake. In vitro macrophage uptake, in vivo biodistribution and pharmacokinetic studies demonstrate that the RBC membrane is a superior alternative to the current gold standard PEG for nanoparticle ‘stealth’. Furthermore, we systematically investigate the in vivo potential toxicity of RBC membrane-coated nanoparticles by blood biochemistry, whole blood panel examination and histology analysis based on animal models. The combination of synthetic nanoparticles and natural cell membranes embodies a novel and biomimetic nanomaterial design strategy and presents a compelling property of functional materials for a broad range of biomedical applications. (paper)

  10. The effect of alcohols on red blood cell mechanical properties and membrane fluidity depends on their molecular size.

    Science.gov (United States)

    Sonmez, Melda; Ince, Huseyin Yavuz; Yalcin, Ozlem; Ajdžanović, Vladimir; Spasojević, Ivan; Meiselman, Herbert J; Baskurt, Oguz K

    2013-01-01

    The role of membrane fluidity in determining red blood cell (RBC) deformability has been suggested by a number of studies. The present investigation evaluated alterations of RBC membrane fluidity, deformability and stability in the presence of four linear alcohols (methanol, ethanol, propanol and butanol) using ektacytometry and electron paramagnetic resonance (EPR) spectroscopy. All alcohols had a biphasic effect on deformability such that it increased then decreased with increasing concentration; the critical concentration for reversal was an inverse function of molecular size. EPR results showed biphasic changes of near-surface fluidity (i.e., increase then decrease) and a decreased fluidity of the lipid core; rank order of effectiveness was butanol > propanol > ethanol > methanol, with a significant correlation between near-surface fluidity and deformability (r = 0.697; palcohol enhanced the impairment of RBC deformability caused by subjecting cells to 100 Pa shear stress for 300 s, with significant differences from control being observed at higher concentrations of all four alcohols. The level of hemolysis was dependent on molecular size and concentration, whereas echinocytic shape transformation (i.e., biconcave disc to crenated morphology) was observed only for ethanol and propanol. These results are in accordance with available data obtained on model membranes. They document the presence of mechanical links between RBC deformability and near-surface membrane fluidity, chain length-dependence of the ability of alcohols to alter RBC mechanical behavior, and the biphasic response of RBC deformability and near-surface membrane fluidity to increasing alcohol concentrations.

  11. Investigating effects of nano-particles infiltration on mechanical properties of cell membrane using atomic force microscopy

    Science.gov (United States)

    Zhang, XiaoYue; Zhang, Yong; Zheng, Yue; Wang, Biao

    2012-06-01

    In this paper, we introduce our finding of the effects of C60 nanoparticles (NP) infiltration on mechanical properties of cell and its membrane. Atomic force microscopy (AFM) is used to perform indentation on both normal and C60 infiltrated red blood cells (RBC) to gain data of mechanical characteristics of the membrane. Our results show that the mechanical properties of human RBC membrane seem to be altered due to the presence of C60 NPs. The resistance and ultimate strength of the C60 infiltrated RBC membrane significantly decrease. We also explain the mechanism of how C60 NPs infiltration changes the mechanical properties of the cell membrane by predicting the structural change of the lipid bilayer caused by the C60 infiltration at molecular level and analyze the interactions among molecules in the lipid bilayer. The potential hazards and application of the change in mechanical characteristics of the RBCs membrane are also discussed. Nanotoxicity of C60 NPs may be significant for some biological cells.

  12. The effect of alcohols on red blood cell mechanical properties and membrane fluidity depends on their molecular size.

    Directory of Open Access Journals (Sweden)

    Melda Sonmez

    Full Text Available The role of membrane fluidity in determining red blood cell (RBC deformability has been suggested by a number of studies. The present investigation evaluated alterations of RBC membrane fluidity, deformability and stability in the presence of four linear alcohols (methanol, ethanol, propanol and butanol using ektacytometry and electron paramagnetic resonance (EPR spectroscopy. All alcohols had a biphasic effect on deformability such that it increased then decreased with increasing concentration; the critical concentration for reversal was an inverse function of molecular size. EPR results showed biphasic changes of near-surface fluidity (i.e., increase then decrease and a decreased fluidity of the lipid core; rank order of effectiveness was butanol > propanol > ethanol > methanol, with a significant correlation between near-surface fluidity and deformability (r = 0.697; p<0.01. The presence of alcohol enhanced the impairment of RBC deformability caused by subjecting cells to 100 Pa shear stress for 300 s, with significant differences from control being observed at higher concentrations of all four alcohols. The level of hemolysis was dependent on molecular size and concentration, whereas echinocytic shape transformation (i.e., biconcave disc to crenated morphology was observed only for ethanol and propanol. These results are in accordance with available data obtained on model membranes. They document the presence of mechanical links between RBC deformability and near-surface membrane fluidity, chain length-dependence of the ability of alcohols to alter RBC mechanical behavior, and the biphasic response of RBC deformability and near-surface membrane fluidity to increasing alcohol concentrations.

  13. Biophysics of malarial parasite exit from infected erythrocytes.

    Science.gov (United States)

    Chandramohanadas, Rajesh; Park, YongKeun; Lui, Lena; Li, Ang; Quinn, David; Liew, Kingsley; Diez-Silva, Monica; Sung, Yongjin; Dao, Ming; Lim, Chwee Teck; Preiser, Peter Rainer; Suresh, Subra

    2011-01-01

    Upon infection and development within human erythrocytes, P. falciparum induces alterations to the infected RBC morphology and bio-mechanical properties to eventually rupture the host cells through parasitic and host derived proteases of cysteine and serine families. We used previously reported broad-spectrum inhibitors (E64d, EGTA-AM and chymostatin) to inhibit these proteases and impede rupture to analyze mechanical signatures associated with parasite escape. Treatment of late-stage iRBCs with E64d and EGTA-AM prevented rupture, resulted in no major RBC cytoskeletal reconfiguration but altered schizont morphology followed by dramatic re-distribution of three-dimensional refractive index (3D-RI) within the iRBC. These phenotypes demonstrated several-fold increased iRBC membrane flickering. In contrast, chymostatin treatment showed no 3D-RI changes and caused elevated fluctuations solely within the parasitophorous vacuole. We show that E64d and EGTA-AM supported PV breakdown and the resulting elevated fluctuations followed non-Gaussian pattern that resulted from direct merozoite impingement against the iRBC membrane. Optical trapping experiments highlighted reduced deformability of the iRBC membranes upon rupture-arrest, more specifically in the treatments that facilitated PV breakdown. Taken together, our experiments provide novel mechanistic interpretations on the role of parasitophorous vacuole in maintaining the spherical schizont morphology, the impact of PV breakdown on iRBC membrane fluctuations leading to eventual parasite escape and the evolution of membrane stiffness properties of host cells in which merozoites were irreversibly trapped, recourse to protease inhibitors. These findings provide a comprehensive, previously unavailable, body of information on the combined effects of biochemical and biophysical factors on parasite egress from iRBCs.

  14. An On-Chip RBC Deformability Checker Significantly Improves Velocity-Deformation Correlation

    Directory of Open Access Journals (Sweden)

    Chia-Hung Dylan Tsai

    2016-10-01

    Full Text Available An on-chip deformability checker is proposed to improve the velocity–deformation correlation for red blood cell (RBC evaluation. RBC deformability has been found related to human diseases, and can be evaluated based on RBC velocity through a microfluidic constriction as in conventional approaches. The correlation between transit velocity and amount of deformation provides statistical information of RBC deformability. However, such correlations are usually only moderate, or even weak, in practical evaluations due to limited range of RBC deformation. To solve this issue, we implemented three constrictions of different width in the proposed checker, so that three different deformation regions can be applied to RBCs. By considering cell responses from the three regions as a whole, we practically extend the range of cell deformation in the evaluation, and could resolve the issue about the limited range of RBC deformation. RBCs from five volunteer subjects were tested using the proposed checker. The results show that the correlation between cell deformation and transit velocity is significantly improved by the proposed deformability checker. The absolute values of the correlation coefficients are increased from an average of 0.54 to 0.92. The effects of cell size, shape and orientation to the evaluation are discussed according to the experimental results. The proposed checker is expected to be useful for RBC evaluation in medical practices.

  15. Molecular cloning of RBCS genes in Selaginella and the evolution of the rbcS gene family

    Directory of Open Access Journals (Sweden)

    Wang Bo

    2015-01-01

    Full Text Available Rubisco small subunits (RBCS are encoded by a nuclear rbcS multigene family in higher plants and green algae. However, owing to the lack of rbcS sequences in lycophytes, the characteristics of rbcS genes in lycophytes is unclear. Recently, the complete genome sequence of the lycophyte Selaginella moellendorffii provided the first insight into the rbcS gene family in lycophytes. To understand further the characteristics of rbcS genes in other Selaginella, the full length of rbcS genes (rbcS1 and rbcS2 from two other Selaginella species were isolated. Both rbcS1 and rbcS2 genes shared more than 97% identity among three Selaginella species. RBCS proteins from Selaginella contained the Pfam RBCS domain F00101, which was a major domain of other plant RBCS proteins. To explore the evolution of the rbcS gene family across Selaginella and other plants, we identified and performed comparative analysis of the rbcS gene family among 16 model plants based on a genome-wide analysis. The results showed that (i two rbcS genes were obtained in Selaginella, which is the second fewest number of rbcS genes among the 16 representative plants; (ii an expansion of rbcS genes occurred in the moss Physcomitrella patens; (iii only RBCS proteins from angiosperms contained the Pfam PF12338 domains, and (iv a pattern of concerted evolution existed in the rbcS gene family. Our study provides new insights into the evolution of the rbcS gene family in Selaginella and other plants.

  16. Experimental evaluation of mechanical and electrical properties of RBC suspensions under flow. Role of RBC deformability

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2010-01-01

    Roč. 25, 3-4 (2010), s. 45-52 ISSN 1313-2458 Institutional research plan: CEZ:AV0Z20600510 Keywords : apparent viscosity * conductivity * RBC suspensions * dextran 70 * PEG 35 000 * glutaraldehyde Subject RIV: BK - Fluid Dynamics

  17. Discriminating plants using the DNA barcode rbcLb: an appraisal based on a large data set.

    Science.gov (United States)

    Dong, Wenpan; Cheng, Tao; Li, Changhao; Xu, Chao; Long, Ping; Chen, Chumming; Zhou, Shiliang

    2014-03-01

    The ideal DNA barcode for plants remains to be discovered, and the candidate barcode rbcL has been met with considerable skepticism since its proposal. In fact, the variability within this gene has never been fully explored across all plant groups from algae to flowering plants, and its performance as a barcode has not been adequately tested. By analysing all of the rbcL sequences currently available in GenBank, we attempted to determine how well a region of rbcL performs as a barcode in species discrimination. We found that the rbcLb region was more variable than the frequently used rbcLa region. Both universal and plant group-specific primers were designed to amplify rbcLb, and the performance of rbcLa and rbcLb was tested in several ways. Using blast, both regions successfully identified all families and nearly all genera; however, the successful species identification rates varied significantly among plant groups, ranging from 24.58% to 85.50% for rbcLa and from 36.67% to 90.89% for rbcLb. Successful species discrimination ranged from 5.19% to 96.33% for rbcLa and from 22.09% to 98.43% for rbcLb in species-rich families, and from 0 to 88.73% for rbcLa and from 2.04% to 100% for rbcLb in species-rich genera. Both regions performed better for lower plants than for higher plants, although rbcLb performed significantly better than rbcLa overall, particularly for angiosperms. Considering the applicability across plants, easy and unambiguous alignment, high primer universality, high sequence quality and high species discrimination power for lower plants, we suggest rbcLb as a universal plant barcode. © 2013 John Wiley & Sons Ltd.

  18. Strategi Perancangan Mutu Ripe Banana Chip (RBC Berbasis Harapan Konsumen

    Directory of Open Access Journals (Sweden)

    Bambang Herry P

    2016-11-01

    Full Text Available Ripe Banana Chip (RBC, merupakan salah satu jenis kripik yang dibuat dari pisang masak. RBC dapat dilakukan dengan menggunakan teknologi penggorengan vakum (vacum frying ataupun pembekuan (freezing. RBC pisang mas cukup banyak memiliki keunggulan dari nilai gizinya. Produk ini masih belum diketahui tingkat kesesuain mutunya dengan keinginan konsumen dilihat dari aspek fisik ataupun organoleptik. Tujuan penelitian ini agar dapat mengetahui rancangan mutu yang tepat untuk produk RBC pisang mas. Penelitian ini menggunakan tiga metode, diantaranya metode skoring, Customer Satisfaction Index (CSI, dan metode diagram tulang ikan. Hasil dari penelitian, yaitu : warna RBC dengan intensitas 5,56 (kuning dan skor 3,862 (suka ; informasi kemasan dengan intensitas 4,5 (setuju dan skor 3,534 (suka ; kenyamanan kemasan dengan intensitas 8,58 (nyaman dan skor 4,155 (suka ; keamanan kemasan dengan intensitas 8,15 (sangat aman dan skor 4,086 (suka ; ketebalan dengan intensitas 8,31(sangat tebal dan skor 1,604 (sangat tidak suka ; Oil dengan intensitas 4,86 (banyak dan skor 2,483 (tidak suka ; kerenyahan dengan intensitas 7,32 (keras dan skor 2,843 (cukup suka ; Easy of breaking dengan intensitas 5,17 (mudah dipatahkan dan skor 3,158 (cukup suka ; rasa manis dengan intensitas 7,89 (manis dan skor 3,208 (cukup suka ; rasa asam dengan intensitas 4,84 (agak asam dan skor 3,309 (cukup suka. Nilai CSI yang dihasilkan, yaitu sebesar 64% (puas. Strategi untuk meningkatkan mutu RBC diantaranya: mengurangi ukuran ketebalan bahan baku sebelum diproses; lebih dipertimbangkan lagi tingkat kematangan pisang; memberi pengarahan dan motivasi kepada pekerja; melakukan pengawasan saat produksi berlangsung; lebih memperhatikan keseragaman ukuran pisang, dan menggunakan alternatif lain dalam penirisan minyak, misalnya sentrifuse agar keberadaan minyak berkurang.

  19. Red blood cell (RBC) suspensions in confined microflows: Pressure-flow relationship.

    Science.gov (United States)

    Stauber, Hagit; Waisman, Dan; Korin, Netanel; Sznitman, Josué

    2017-10-01

    Microfluidic-based assays have become increasingly popular to explore microcirculation in vitro. In these experiments, blood is resuspended to a desired haematocrit level in a buffer solution, where frequent choices for preparing RBC suspensions comprise notably Dextran and physiological buffer. Yet, the rational for selecting one buffer versus another is often ill-defined and lacks detailed quantification, including ensuing changes in RBC flow characteristics. Here, we revisit RBC suspensions in microflows and attempt to quantify systematically some of the differences emanating between buffers. We measure bulk flow rate (Q) of RBC suspensions, using PBS- and Dextran-40, as a function of the applied pressure drop (ΔP) for two hematocrits (∼0% and 23%). Two distinct microfluidic designs of varying dimensions are employed: a straight channel larger than and a network array similar to the size of individual RBCs. Using the resulting pressure-flow curves, we extract the equivalent hydrodynamic resistances and estimate the relative viscosities. These efforts are a first step in rigorously quantifying the influence of the 'background' buffer on RBC flows within microfluidic devices and thereby underline the importance of purposefully selecting buffer suspensions for microfluidic in vitro assays. Copyright © 2017. Published by Elsevier Ltd.

  20. Modification of host erythrocyte membranes by trypsin and chymotrypsin treatments and effects on the in vitro growth of bovine and equine Babesia parasites.

    Science.gov (United States)

    Okamura, Masashi; Yokoyama, Naoaki; Takabatake, Noriyuki; Okubo, Kazuhiro; Ikehara, Yuzuru; Igarashi, Ikuo

    2007-02-01

    In the present study, we investigated the effects of protease pretreatments of host erythrocytes (RBC) on the in vitro growth of bovine Babesia parasites (Babesia bovis and B. bigemina) and equine Babesia parasites (B. equi and B. caballi). The selected proteases, trypsin and chymotrypsin, clearly modified several membrane proteins of both bovine and equine RBC, as demonstrated by SDS-PAGE analysis; however, the protease treatments also modified the sialic acid content exclusively in bovine RBC, as demonstrated by lectin blot analysis. An in vitro growth assay using the protease-treated RBC showed that the trypsin-treated bovine RBC, but not the chymotrypsin-treated ones, significantly reduced the growth of B. bovis and B. bigemina as compared to the control. In contrast, the growth of B. equi and B. caballi was not affected by any of these proteases. Thus, the bovine, but not the equine, Babesia parasites require the trypsin-sensitive membrane (sialoglyco) proteins to infect the RBC.

  1. The study of x-ray photo-electron spectroscopy of 99mTc-RBC

    International Nuclear Information System (INIS)

    Song Chunyi

    1994-01-01

    99m Tc-RBC are widely used as visualization agents for a blood pool. In this research 99m Tc-RBC was prepared by in vivo labeling. The chemical state and changes of 99m Tc atoms in 99m Tc-RBC was determined by x-ray photo-electron spectroscopy (XPS). The stability of 99m Tc-RBC is best shown by the determination of XPS at one hour or at two hours after labeling. There are two ways of coordination of bonding of RBC and 99m Tc: One is the coordination of 99m Tc with the oxygen atom which carries a negative charge of the carboxyl radical on the polypeptide bond, the other is the coordination of 99m Tc with a sulfur atom which caries the negative charge of cysteine. From the E b value of 99m Tc-RBC 99m Tc 3d5/2, it can be inferred that 99m Tc of 99m Tc-RBC is less than a trivalent. At the same time, the results of the determination by XPS with the compounds containing 99 TcO 4 - , 99 Tc(V), 99 Tc(IV) and 99 Tc(III) show that the chemical shift is lowered as the reduction state is lowered. Experimental results coincide with theoretical inferences

  2. Elastic behavior of a red blood cell with the membrane's nonuniform natural state: equilibrium shape, motion transition under shear flow, and elongation during tank-treading motion.

    Science.gov (United States)

    Tsubota, Ken-Ichi; Wada, Shigeo; Liu, Hao

    2014-08-01

    Direct numerical simulations of the mechanics of a single red blood cell (RBC) were performed by considering the nonuniform natural state of the elastic membrane. A RBC was modeled as an incompressible viscous fluid encapsulated by an elastic membrane. The in-plane shear and area dilatation deformations of the membrane were modeled by Skalak constitutive equation, while out-of-plane bending deformation was formulated by the spring model. The natural state of the membrane with respect to in-plane shear deformation was modeled as a sphere ([Formula: see text]), biconcave disk shape ([Formula: see text]) and their intermediate shapes ([Formula: see text]) with the nonuniformity parameter [Formula: see text], while the natural state with respect to out-of-plane bending deformation was modeled as a flat plane. According to the numerical simulations, at an experimentally measured in-plane shear modulus of [Formula: see text] and an out-of-plane bending rigidity of [Formula: see text] of the cell membrane, the following results were obtained. (i) The RBC shape at equilibrium was biconcave discoid for [Formula: see text] and cupped otherwise; (ii) the experimentally measured fluid shear stress at the transition between tumbling and tank-treading motions under shear flow was reproduced for [Formula: see text]; (iii) the elongation deformation of the RBC during tank-treading motion from the simulation was consistent with that from in vitro experiments, irrespective of the [Formula: see text] value. Based on our RBC modeling, the three phenomena (i), (ii), and (iii) were mechanically consistent for [Formula: see text]. The condition [Formula: see text] precludes a biconcave discoid shape at equilibrium (i); however, it gives appropriate fluid shear stress at the motion transition under shear flow (ii), suggesting that a combined effect of [Formula: see text] and the natural state with respect to out-of-plane bending deformation is necessary for understanding details of the

  3. Experimental evaluation of mechanical and electrical properties of RBC suspensions under flow. Role of RBC aggregating agent

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2010-01-01

    Roč. 45, 2-4 (2010), s. 253-261 ISSN 1386-0291 R&D Projects: GA AV ČR IAA200600803 Institutional research plan: CEZ:AV0Z20600510 Keywords : apparent viscosity * conductivity * unsteady flow * RBC suspensions * dextrans * PEG Subject RIV: BK - Fluid Dynamics Impact factor: 2.838, year: 2010

  4. Preoperative diagnosis of orbital cavernous hemangioma: a 99mTc-RBC SPECT study.

    Science.gov (United States)

    Burroni, Luca; Borsari, Giulia; Pichierri, Patrizia; Polito, Ennio; Toscano, Olga; Grassetto, Gaia; Al-Nahhas, Adil; Rubello, Domenico; Vattimo, Angelo Giuseppe

    2012-11-01

    This study aimed to describe 99mTc-labeled RBC scintigraphy as a diagnostic method for orbital cavernous hemangiomas and to evaluate this diagnostic tool according to surgical outcomes. Fifty-five patients with clinical and radiological (US, CT, and/or MRI) suspicion of unilateral cavernous hemangioma of the orbit underwent 99mTc-RBC SPECT study.Qualitative and semiquantitative evaluations were performed, and results were statistically analyzed. SPECT images showed focal uptake in the orbital mass in 36 of 55 patients. Nineteen patients had a negative scintigraphic pattern, with concordance of early and late absence of uptake of 99mTc-RBC.Our procedure showed 100% sensitivity and 88.9% specificity for the diagnosis of orbital cavernous hemangioma, with a positive predictive value of 90.9% and a negative predictive value of 100%. 99mTc-RBC imaging is safe, easy to perform, and highly accurate in providing adequate clinical and surgical management. As a noninvasive and highly specific method for diagnosing orbital hemangioma, 99mTc-RBC scintigraphy can avoid more invasive imaging or biopsy.

  5. Multiple-capillary measurement of RBC speed, flux, and density with optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Wu, Weicheng; Lesage, Frederic; Boas, David A

    2013-11-01

    As capillaries exhibit heterogeneous and fluctuating dynamics even during baseline, a technique measuring red blood cell (RBC) speed and flux over many capillaries at the same time is needed. Here, we report that optical coherence tomography can capture individual RBC passage simultaneously over many capillaries located at different depths. Further, we demonstrate the ability to quantify RBC speed, flux, and linear density. This technique will provide a means to monitor microvascular flow dynamics over many capillaries at different depths at the same time.

  6. Enteropathogenic Escherichia coli translocate Tir and form an intimin-Tir intimate attachment to red blood cell membranes.

    Science.gov (United States)

    Shaw, Robert K; Daniell, Sarah; Frankel, Gad; Knutton, Stuart

    2002-05-01

    Type III secretion allows bacteria to inject effector proteins into host cells. In enteropathogenic Escherichia coli (EPEC) the type III secreted protein, Tir, is translocated to the host-cell plasma membrane where it functions as a receptor for the bacterial adhesin intimin, leading to intimate bacterial attachment and "attaching and effacing" (A/E) lesion formation. To study EPEC type III secretion the interaction of EPEC with monolayers of red blood cells (RBCs) has been exploited and in a recent study [Shaw, R. K., Daniell, S., Ebel, F., Frankel, G. & Knutton, S. (2001 ). Cell Microbiol 3, 213-222] it was shown that EPEC induced haemolysis of RBCs and translocation of EspD, a putative pore-forming type III secreted protein in the RBC membrane. Here it is demonstrated that EPEC are able to translocate and correctly insert Tir into the RBC membrane and produce an intimin-Tir intimate bacterial attachment, identical to that seen in A/E lesions. Following translocation Tir did not undergo any change in apparent molecular mass or become tyrosine-phosphorylated and there was no focusing of RBC cytoskeletal actin beneath intimately adherent bacteria, and no pedestal formation. This study, employing an RBC model of infection, has demonstrated that Tir translocation can be separated from host-cell-mediated Tir modifications; the data show that the EPEC type III protein translocation apparatus is sufficient to deliver and correctly insert Tir into host-cell membranes independent of eukaryotic cell functions.

  7. Atomic Force Microscopy Study on the Stiffness of Nanosized Liposomes Containing Charged Lipids.

    Science.gov (United States)

    Takechi-Haraya, Yuki; Goda, Yukihiro; Sakai-Kato, Kumiko

    2018-06-18

    It has recently been recognized that the mechanical properties of lipid nanoparticles play an important role during in vitro and in vivo behaviors such as cellular uptake, blood circulation, and biodistribution. However, there have been no quantitative investigations of the effect of commonly used charged lipids on the stiffness of nanosized liposomes. In this study, by means of atomic force microscopy (AFM), we quantified the stiffness of nanosized liposomes composed of neutrally charged lipids combined with positively or negatively charged lipids while simultaneously imaging the liposomes in aqueous medium. Our results showed that charged lipids, whether negatively or positively charged, have the effect of reducing the stiffness of nanosized liposomes, independently of the saturation degree of the lipid acyl chains; the measured stiffness values of liposomes containing charged lipids are 30-60% lower than those of their neutral counterpart liposomes. In addition, we demonstrated that the Laurdan generalized polarization values, which are related to the hydration degree of the liposomal membrane interface and often used as a qualitative indicator of liposomal membrane stiffness, do not directly correlate with the physical stiffness values of the liposomes prepared in this study. However, our results indicate that direct quantitative AFM measurement is a valuable method to gain molecular-scale information about how the hydration degree of liposomal interfaces reflects (or does not reflect) liposome stiffness as a macroscopic property. Our AFM method will contribute to the quantitative characterization of the nano-bio interaction of nanoparticles and to the optimization of the lipid composition of liposomes for clinical use.

  8. Convection due to an unstable density difference across a permeable membrane

    Science.gov (United States)

    Puthenveettil, Baburaj A.; Arakeri, Jaywant H.

    We study natural convection driven by unstable concentration differences of sodium chloride (NaCl) across a horizontal permeable membrane at Rayleigh numbers (Ra) of 1010 to 1011 and Schmidt number (Sc)=600. A layer of brine lies over a layer of distilled water, separated by the membrane, in square-cross-section tanks. The membrane is permeable enough to allow a small flow across it at higher driving potentials. Based on the predominant mode of transport across the membrane, three regimes of convection, namely an advection regime, a diffusion regime and a combined regime, are identified. The near-membrane flow in all the regimes consists of sheet plumes formed from the unstable layers of fluid near the membrane. In the advection regime observed at higher concentration differences (Bb) show a common log-normal probability density function at all Ra. We propose a phenomenology which predicts /line{lambda}_b sqrt{Z_w Z_{V_i}}, where Zw and Z_{V_i} are, respectively, the near-wall length scales in Rayleighnard convection (RBC) and due to the advection velocity. In the combined regime, which occurs at intermediate values of C/2)4/3. At lower driving potentials, in the diffusion regime, the flux scaling is similar to that in turbulent RBC.

  9. Estimation of adult and neonatal RBC lifespans in anemic neonates using RBCs labeled at several discrete biotin densities.

    Science.gov (United States)

    Kuruvilla, Denison J; Widness, John A; Nalbant, Demet; Schmidt, Robert L; Mock, Donald M; An, Guohua; Veng-Pedersen, Peter

    2017-06-01

    Prior conclusions that autologous neonatal red blood cells (RBC) have substantially shorter lifespans than allogeneic adult RBCs were not based on direct comparison of autologous neonatal vs. allogeneic adult RBCs performed concurrently in the same infant. Biotin labeling of autologous neonatal RBCs and allogeneic adult donor RBCs permits concurrent direct comparison of autologous vs. allogeneic RBC lifespan. RBCs from 15 allogeneic adult donors and from 15 very-low-birth-weight (VLBW) neonates were labeled at separate biotin densities and transfused simultaneously into the 15 neonates. Two mathematical models that account for the RBC differences were employed to estimate lifespans for the two RBC populations. Mean ± SD lifespan for adult allogeneic RBC was 70.1 ± 19.1 d, which is substantially shorter than the 120 d lifespan of both autologous and adult allogeneic RBC in healthy adults. Mean ± SD lifespan for neonatal RBC was 54.2 ± 11.3 d, which is only about 30% shorter than that of the adult allogeneic RBCs. This study provides evidence that extrinsic environmental factors primarily determine RBC survival (e.g., small bore of the capillaries of neonates, rate of oxygenation/deoxygenation cycles) rather than factors intrinsic to RBC.

  10. Relationship between Static Stiffness and Modal Stiffness of Structures

    Directory of Open Access Journals (Sweden)

    Tianjian Ji Tianjian Ji

    2010-02-01

    Full Text Available This paper derives the relationship between the static stiffness and modal stiffness of a structure. The static stiffness and modal stiffness are two important concepts in both structural statics and dynamics. Although both stiffnesses indicate the capacity of the structure to resist deformation, they are obtained using different methods. The former is calculated by solving the equations of equilibrium and the latter can be obtained by solving an eigenvalue problem. A mathematical relationship between the two stiffnesses was derived based on the definitions of two stiffnesses. This relationship was applicable to a linear system and the derivation of relationships does not reveal any other limitations. Verification of the relationship was given by using several examples. The relationship between the two stiffnesses demonstrated that the modal stiffness of the fundamental mode was always larger than the static stiffness of a structure if the critical point and the maximum mode value are at the same node, i.e. for simply supported beam and seven storeys building are 1.5% and 15% respectively. The relationship could be applied into real structures, where the greater the number of modes being considered, the smaller the difference between the modal stiffness and the static stiffness of a structure.

  11. Oxidative Stress Parameters and Erythrocyte Membrane Adenosine Triphosphatase Activities in Streptozotocin-induced Diabetic Rats Administered Aqueous Preparation of Kalanchoe Pinnata Leaves.

    Science.gov (United States)

    Menon, Nikhil; Sparks, Jean; Omoruyi, Felix O

    2016-01-01

    Diabetes mellitus is a chronic metabolic disease that according to the World Health Organization affects more than 382 million people. The rise in diabetes mellitus coupled with the lack of an effective treatment has led many to investigate medicinal plants to identify a viable alternative. To evaluate red blood cell (RBC) membrane adenosine triphosphatase (ATPase) activities and antioxidant levels in streptozotocin-induced diabetic rats administered aqueous preparation of Kalanchoe pinnata leaves. Diabetes mellitus was induced in rats by a single administration of streptozotocin (60 mg/kg). Diabetic rats were then treated with aqueous K. pinnata preparation (three mature leaves ~ 9.96 g/70 kg body weight or about 0.14 g/kg body weight/day) for 30 days. Serum glucose, RBC membrane ATPase activities, and antioxidant levels were determined. We noted weight loss and reduced food consumption in the treated diabetic group. Serum glucose levels were reduced in the treated diabetic group compared to the other groups. Superoxide dismutase activity and glutathione levels were not significantly elevated in the treated group compared to the diabetic group. However, serum catalase activity was significantly (P < 0.05) increased in the treated diabetic group compared to the other groups. Serum thiobarbituric acid reactive substances were not significantly altered among the groups. There was a significant (P < 0.05) increase in Mg(2+) ATPase activity and a nonsignificant increase in Na(+)/K(+) ATPase activity in the RBC membrane of the treated diabetic group compared to the diabetic group. The consumption of aqueous preparation of K. pinnata may accrue benefits in the management of diabetes by lowering oxidative stress often associated with the disease and improving the availability of cellular magnesium through an increase in the magnesium ATPase pump in the RBC membrane for increased cellular metabolism of glucose through the glycolytic pathway. We noted weight loss and

  12. Substrate stiffness affects skeletal myoblast differentiation in vitro

    Directory of Open Access Journals (Sweden)

    Sara Romanazzo, Giancarlo Forte, Mitsuhiro Ebara, Koichiro Uto, Stefania Pagliari, Takao Aoyagi, Enrico Traversa and Akiyoshi Taniguchi

    2012-01-01

    Full Text Available To maximize the therapeutic efficacy of cardiac muscle constructs produced by stem cells and tissue engineering protocols, suitable scaffolds should be designed to recapitulate all the characteristics of native muscle and mimic the microenvironment encountered by cells in vivo. Moreover, so not to interfere with cardiac contractility, the scaffold should be deformable enough to withstand muscle contraction. Recently, it was suggested that the mechanical properties of scaffolds can interfere with stem/progenitor cell functions, and thus careful consideration is required when choosing polymers for targeted applications. In this study, cross-linked poly-ε-caprolactone membranes having similar chemical composition and controlled stiffness in a supra-physiological range were challenged with two sources of myoblasts to evaluate the suitability of substrates with different stiffness for cell adhesion, proliferation and differentiation. Furthermore, muscle-specific and non-related feeder layers were prepared on stiff surfaces to reveal the contribution of biological and mechanical cues to skeletal muscle progenitor differentiation. We demonstrated that substrate stiffness does affect myogenic differentiation, meaning that softer substrates can promote differentiation and that a muscle-specific feeder layer can improve the degree of maturation in skeletal muscle stem cells.

  13. Phase separation of the plasma membrane in human red blood cells as a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus.

    Science.gov (United States)

    Maulucci, Giuseppe; Cordelli, Ermanno; Rizzi, Alessandro; De Leva, Francesca; Papi, Massimiliano; Ciasca, Gabriele; Samengo, Daniela; Pani, Giovambattista; Pitocco, Dario; Soda, Paolo; Ghirlanda, Giovanni; Iannello, Giulio; De Spirito, Marco

    2017-01-01

    Glycosylation, oxidation and other post-translational modifications of membrane and transmembrane proteins can alter lipid density, packing and interactions, and are considered an important factor that affects fluidity variation in membranes. Red blood cells (RBC) membrane physical state, showing pronounced alterations in Type 1 diabetes mellitus (T1DM), could be the ideal candidate for monitoring the disease progression and the effects of therapies. On these grounds, the measurement of RBC membrane fluidity alterations can furnish a more sensitive index in T1DM diagnosis and disease progression than Glycosylated hemoglobin (HbA1c), which reflects only the information related to glycosylation processes. Here, through a functional two-photon microscopy approach we retrieved fluidity maps at submicrometric scale in RBC of T1DM patients with and without complications, detecting an altered membrane equilibrium. We found that a phase separation between fluid and rigid domains occurs, triggered by systemic effects on membranes fluidity of glycation and oxidation. The phase separation patterns are different among healthy, T1DM and T1DM with complications patients. Blood cholesterol and LDL content are positively correlated with the extent of the phase separation patterns. To quantify this extent a machine learning approach is employed to develop a Decision-Support-System (DSS) able to recognize different fluidity patterns in RBC. Preliminary analysis shows significant differences(pBlood cells is a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus, and could allow customization and the selection of medical treatments in T1DM in clinical settings, and enable the early detection of complications.

  14. Elastic metamaterial beam with remotely tunable stiffness

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Wei [University of Michigan–Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai 200240 (China); Yu, Zhengyue [School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Wang, Xiaole [School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Lai, Yun [College of Physics, Optoelectronics and Energy & Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou 215006 (China); Yellen, Benjamin B., E-mail: yellen@duke.edu [University of Michigan–Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai 200240 (China); Department of Mechanical Engineering and Materials Science, Duke University, P.O. Box 90300, Hudson Hall, Durham, North Carolina 27708 (United States)

    2016-02-07

    We demonstrate a dynamically tunable elastic metamaterial, which employs remote magnetic force to adjust its vibration absorption properties. The 1D metamaterial is constructed from a flat aluminum beam milled with a linear array of cylindrical holes. The beam is backed by a thin elastic membrane, on which thin disk-shaped permanent magnets are mounted. When excited by a shaker, the beam motion is tracked by a Laser Doppler Vibrometer, which conducts point by point scanning of the vibrating element. Elastic waves are unable to propagate through the beam when the driving frequency excites the first elastic bending mode in the unit cell. At these frequencies, the effective mass density of the unit cell becomes negative, which induces an exponentially decaying evanescent wave. Due to the non-linear elastic properties of the membrane, the effective stiffness of the unit cell can be tuned with an external magnetic force from nearby solenoids. Measurements of the linear and cubic static stiffness terms of the membrane are in excellent agreement with experimental measurements of the bandgap shift as a function of the applied force. In this implementation, bandgap shifts by as much as 40% can be achieved with ∼30 mN of applied magnetic force. This structure has potential for extension in 2D and 3D, providing a general approach for building dynamically tunable elastic metamaterials for applications in lensing and guiding elastic waves.

  15. Elastic metamaterial beam with remotely tunable stiffness

    Science.gov (United States)

    Qian, Wei; Yu, Zhengyue; Wang, Xiaole; Lai, Yun; Yellen, Benjamin B.

    2016-02-01

    We demonstrate a dynamically tunable elastic metamaterial, which employs remote magnetic force to adjust its vibration absorption properties. The 1D metamaterial is constructed from a flat aluminum beam milled with a linear array of cylindrical holes. The beam is backed by a thin elastic membrane, on which thin disk-shaped permanent magnets are mounted. When excited by a shaker, the beam motion is tracked by a Laser Doppler Vibrometer, which conducts point by point scanning of the vibrating element. Elastic waves are unable to propagate through the beam when the driving frequency excites the first elastic bending mode in the unit cell. At these frequencies, the effective mass density of the unit cell becomes negative, which induces an exponentially decaying evanescent wave. Due to the non-linear elastic properties of the membrane, the effective stiffness of the unit cell can be tuned with an external magnetic force from nearby solenoids. Measurements of the linear and cubic static stiffness terms of the membrane are in excellent agreement with experimental measurements of the bandgap shift as a function of the applied force. In this implementation, bandgap shifts by as much as 40% can be achieved with ˜30 mN of applied magnetic force. This structure has potential for extension in 2D and 3D, providing a general approach for building dynamically tunable elastic metamaterials for applications in lensing and guiding elastic waves.

  16. Isolation, expression and characterization of rbcL gene from Ulva prolifera J. Agardh (Ulvophyceae, Chlorophyta)

    Science.gov (United States)

    Shao, Zhanru; Li, Wei; Guo, Hui; Duan, Delin

    2015-12-01

    Ulva prolifera is a typical green alga in subtidal areas and can grow tremendously fast. A highly efficient Rubisco enzyme which is encoded by UpRbcL gene may contribute to the rapid growth. In this study, the full-length UpRbcL open reading frame (ORF) was identified, which encoded a protein of 474 amino acids. Phylogenetic analysis of UpRbcL sequences revealed that Chlorophyta had a closer genetic relationship with higher plants than with Rhodophyta and Phaeophyta. The two distinct residues (aa11 and aa91) were presumed to be unique for Rubisco catalytic activity. The predicted three-dimensional structure showed that one α/β-barrel existed in the C-terminal region, and the sites for Mg2+ coordination and CO2 fixation were also located in this region. Gene expression profile indicated that UpRbcL was expressed at a higher level under light exposure than in darkness. When the culture temperature reached 35°C, the expression level of UpRbcL was 2.5-fold lower than at 15°C, and the carboxylase activity exhibited 13.8-fold decrease. UpRbcL was heterologously expressed in E. coli and was purified by Ni2+ affinity chromatography. The physiological and biochemical characterization of recombinant Rubisco will be explored in the future.

  17. The effect of curvature on the undulation spectrum of Red Blood Cell membranes

    Science.gov (United States)

    Kuriabova, Tatiana; Henle, Mark L.; Levine, Alex J.

    2009-03-01

    The human red blood cell (RBC) membrane has a composite structure of a fluid lipid bilayer tethered to an elastic 2D spectrin network. The study of the mechanical properties of RBCs is crucial to our understanding of their ability withstand large amplitude deformations during their passage through the microvasculature. The linear mechanical response of this composite membrane can be measured by observing its undulatory dynamics in thermal equilibrium, i.e. microrheology. Previous models of these dynamics postulated an effective surface tension. In this talk, we show that surface tension is not necessary. Rather, the coupling of membrane bending to spectrin network compression by curvature can account for the observed dynamics. We use a simplified theoretical model to describe the undulatory dynamics of RBCs, measured experimentally by the Popescu group.ootnotetextG. Popescu et al. ``Imaging red blood cell dynamics by quantitative phase microscopy, Blood Cells, Molecules, and Diseases, (2008), in print'' Analyzing their data using our model, we observe dramatic changes in RBC membrane elasticity associated with cells' morphological transition from discocytes to echinocyte to spherocyte.

  18. Tc-99m Labeled Red Blood Cell by Ultra Tag RBC Kit in Patients Suspected of Gastrointestinal Bleeding

    International Nuclear Information System (INIS)

    Pusuwan, Pawana; Leaungwutiwong, Suraphong; Tocharoenchai, Chiraporn; Chaiwatanarat, Tawatchai; Sirisatipoch, Sasitorn; Rajadara, Samart; Naktong, Thanyada; Thanyarak, Sucheera

    2001-06-01

    Twenty patients suspected of gastrointestinal bleeding who underwent Tc-99m labeled red blood cell (RBC) by ultraTag RBC kit at Division of Nuclear Medicine, Bumrungrad Hospital between January 2000 and December 2002 were studied. The histories of patients together with either endoscopic results or angiographic findings or pathological reports were used as gold standards. Two by Two decision matrix was used for data analysis and the sensitivity together with specificity were calculated. The results show that the sensitivity and specificity of Tc-99m labeled RBC by ultraTag RBC kit are 87.5% and 91.7%, respectively. We conclude that Tc-99m labeled RBC by ultraTag RBC kit gives high percentages of sensitivity and specificity. Moreover, the image quality is improved because of the absence of free Tc-99m pertechnetate uptake in the stomach in all patients

  19. Evaluation of serum homocysteine, high-sensitivity CRP, and RBC folate in patients with alopecia areata

    Directory of Open Access Journals (Sweden)

    Maryam Yousefi

    2014-01-01

    Full Text Available Introduction: Alopecia areata (AA is a common type of hair loss with an autoimmune basis. As the role of homocysteine (Hcys, folate, and CRP has been considered in some autoimmune diseases. Objectives: To evaluate homocysteine, folate and CRP level in AA. Methods: This study was performed on 29 patients who had AA for at least 6 months affecting more than 20% of scalp, and 32 healthy controls. Levels of serum Hcys, blood high-sensitivity CRP, and RBC folate were measured in all subjects. Results: The mean level of RBC folate was significantly lower in the patient group than that in controls (P < 0.001. Also, the level of RBC folate was significantly lower in patients with extensive forms of disease (alopecia totalis/alopecia universalis in comparison with more localized form (patchy hair loss (P < 0.05. Patients with higher "Severity of Alopecia Total" (SALT score had lower RBC folate, as well. Serum Hcys and blood high-sensitivity CRP levels did not show a significant difference in two groups. Conclusion: Patients with alopecia areata have lower level of RBC folate which is in negative correlation with both severity and extension of AA.

  20. Association of Gastrocnemius Muscle Stiffness With Passive Ankle Joint Stiffness and Sex-Related Difference in the Joint Stiffness.

    Science.gov (United States)

    Chino, Kintaro; Takashi, Hideyuki

    2017-11-15

    Passive ankle joint stiffness is affected by all structures located within and over the joint, and is greater in men than in women. Localized muscle stiffness can be assessed by ultrasound shear wave elastography, and muscle architecture such as fascicle length and pennation angle can be measured by B-mode ultrasonography. Thus, we assessed localized muscle stiffness of the medial gastrocnemius (MG) with consideration of individual variability in the muscle architecture, and examined the association of the muscle stiffness with passive ankle joint stiffness and the sex-related difference in the joint stiffness. Localized muscle stiffness of the MG in 16 men and 17 women was assessed at 10° and 20° plantar flexion, neutral anatomical position, 10° and 20° dorsiflexion. Fascicle length and pennation angle of the MG were measured at these joint positions. Passive ankle joint stiffness was determined by the ankle joint angle-torque relationship. Localized MG muscle stiffness was not significantly correlated with passive ankle joint stiffness, and did not show significant sex-related difference, even when considering the muscle architecture. This finding suggest that muscle stiffness of the MG would not be a prominent factor to determine passive ankle joint stiffness and the sex-related difference in the joint stiffness.

  1. Phase separation of the plasma membrane in human red blood cells as a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Giuseppe Maulucci

    Full Text Available Glycosylation, oxidation and other post-translational modifications of membrane and transmembrane proteins can alter lipid density, packing and interactions, and are considered an important factor that affects fluidity variation in membranes. Red blood cells (RBC membrane physical state, showing pronounced alterations in Type 1 diabetes mellitus (T1DM, could be the ideal candidate for monitoring the disease progression and the effects of therapies. On these grounds, the measurement of RBC membrane fluidity alterations can furnish a more sensitive index in T1DM diagnosis and disease progression than Glycosylated hemoglobin (HbA1c, which reflects only the information related to glycosylation processes. Here, through a functional two-photon microscopy approach we retrieved fluidity maps at submicrometric scale in RBC of T1DM patients with and without complications, detecting an altered membrane equilibrium. We found that a phase separation between fluid and rigid domains occurs, triggered by systemic effects on membranes fluidity of glycation and oxidation. The phase separation patterns are different among healthy, T1DM and T1DM with complications patients. Blood cholesterol and LDL content are positively correlated with the extent of the phase separation patterns. To quantify this extent a machine learning approach is employed to develop a Decision-Support-System (DSS able to recognize different fluidity patterns in RBC. Preliminary analysis shows significant differences(p<0.001 among healthy, T1DM and T1DM with complications patients. The development of an assay based on Phase separation of the plasma membrane of the Red Blood cells is a potential tool for diagnosis and progression monitoring of type 1 diabetes mellitus, and could allow customization and the selection of medical treatments in T1DM in clinical settings, and enable the early detection of complications.

  2. Haemostatic function and biomarkers of endothelial damage before and after RBC transfusion in patients with haematologic disease

    DEFF Research Database (Denmark)

    Larsen, A M; Leinøe, E B; Johansson, P I

    2015-01-01

    function and the endothelium) to RBC transfusion. MATERIALS AND METHODS: Blood was sampled from patients with various transfusion-dependent haematologic diseases before 1 and 24 h after RBC transfusion. Primary and secondary haemostasis was evaluated by whole-blood impedance aggregometry (Multiplate....... Compared to before transfusion, patients had slightly reduced coagulability 1 h after RBC transfusion, assessed by TEG. However, transfusion of older RBC products (>14 days) was associated with increased coagulability (all P level of syndecan-1 increased slightly 24 h after transfusion (median....... The changes observed were small to moderate and the clinical relevance of these findings should be investigated in larger studies....

  3. Experimental evaluation of mechanical and electrical properties of RBC suspensions in Dextran and PEG under flow II. Role of RBC deformability and morphology

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.; Gluhcheva, Y.

    2011-01-01

    Roč. 49, 1-4 (2011), s. 441-450 ISSN 1386-0291 Institutional research plan: CEZ:AV0Z20600510 Keywords : RBC suspensions * conductivity * Dextran 70 * Polyethylene glycol 35 000 ( PEG ) Subject RIV: BK - Fluid Dynamics Impact factor: 3.398, year: 2011

  4. Experimental evaluation of mechanical and electrical properties of RBC suspensions in Dextran and PEG under flow II. Role of RBC deformability and morphology

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.; Gluhcheva, Y.

    2011-01-01

    Roč. 49, 1-4 (2011), s. 441-450 ISSN 1386-0291 Institutional research plan: CEZ:AV0Z20600510 Keywords : RBC suspensions * conductivity * Dextran 70 * Polyethylene glycol 35 000 (PEG) Subject RIV: BK - Fluid Dynamics Impact factor: 3.398, year: 2011

  5. Investigating the effect of cell substrate on cancer cell stiffness by optical tweezers.

    Science.gov (United States)

    Yousafzai, Muhammad Sulaiman; Coceano, Giovanna; Bonin, Serena; Niemela, Joseph; Scoles, Giacinto; Cojoc, Dan

    2017-07-26

    The mechanical properties of cells are influenced by their microenvironment. Here we report cell stiffness alteration by changing the cell substrate stiffness for isolated cells and cells in contact with other cells. Polydimethylsiloxane (PDMS) is used to prepare soft substrates with three different stiffness values (173, 88 and 17kPa respectively). Breast cancer cells lines, namely HBL-100, MCF-7 and MDA-MB-231 with different level of aggressiveness are cultured on these substrates and their local elasticity is investigated by vertical indentation of the cell membrane. Our preliminary results show an unforeseen behavior of the MDA-MB-231 cells. When cultured on glass substrate as isolated cells, they are less stiff than the other two types of cells, in agreement with the general statement that more aggressive and metastatic cells are softer. However, when connected to other cells the stiffness of MDA-MB-231 cells becomes similar to the other two cell lines. Moreover, the stiffness of MDA-MB-231 cells cultured on soft PDMS substrates is significantly higher than the stiffness of the other cell types, demonstrating thus the strong influence of the environmental conditions on the mechanical properties of the cells. Copyright © 2017. Published by Elsevier Ltd.

  6. Rotational dynamics of C60 in Na2RbC60

    International Nuclear Information System (INIS)

    Christides, C.; Prassides, K.; Neumann, D.A.; Copley, J.R.D.; Mizuki, J.; Tanigaki, K.; Hirosawa, I.; Ebbesen, T.W.

    1993-01-01

    We have measured the low-energy neutron inelastic-scattering (NIS) spectra of superconducting Na 2 RbC 60 in the temperature range 50-350 K. Well-defined librational peaks are observed at 50 K at 2.83(17) meV (FWHM = 1.7(5) meV). They soften and broaden with increasing temperature. Their behaviour mimics that found in solid C 60 and differs markedly from K 3 C 60 . The rotational barrier for C 60 reorientations in Na 2 RbC 60 is somewhat higher than in pristine C 60 and approximately half as large as in K 3 C 60 . An order-disorder transition is anticipated at a temperature higher than that found in C 60 . (orig.)

  7. Placentography with technetium-99m labelled RBC - an evaluation

    International Nuclear Information System (INIS)

    Jayachandran, C.A.; Benjamin, C.S.; Balakrishnan; Narasimhan

    1983-01-01

    During 1979-80, placentography was performed in 40 cases of pregnant women with third trimester bleeding. Random labelled RBC with sup(99m)Tc of activity 2-3 mci was used, depending upon the weight of the patient. In 98% of cases, the isotope finding was confirmed. (author)

  8. Discriminatory power of rbcL barcode locus for authentication of some of United Arab Emirates (UAE) native plants.

    Science.gov (United States)

    Maloukh, Lina; Kumarappan, Alagappan; Jarrar, Mohammad; Salehi, Jawad; El-Wakil, Houssam; Rajya Lakshmi, T V

    2017-06-01

    DNA barcoding of United Arab Emirates (UAE) native plants is of high practical and scientific value as the plants adapt to very harsh environmental conditions that challenge their identification. Fifty-one plant species belonged to 22 families, 2 monocots, and 20 eudicots; a maximum number of species being legumes and grasses were collected. To authenticate the morphological identification of the wild plant taxa, rbcL and matK regions were used in the study. The primer universality and discriminatory power of rbcL is 100%, while it is 35% for matK locus for these plant species. The sequences were submitted to GenBank; accession numbers were obtained for all the rbcL sequences and for 6 of matK sequences. We suggest rbcL as a promising barcode locus for the tested group of 51 plants. In the present study, an inexpensive, simple method of identification of rare desert plant taxa through rbcL barcode is being reported.

  9. Coupling between the Output Force and Stiffness in Different Variable Stiffness Actuators

    Directory of Open Access Journals (Sweden)

    Amir Jafari

    2014-08-01

    Full Text Available The fundamental objective in developing variable stiffness actuators is to enable the actuator to deliberately tune its stiffness. This is done through controlling the energy flow extracted from internal power units, i.e., the motors of a variable stiffness actuator (VSA. However, the stiffness may also be unintentionally affected by the external environment, over which, there is no control. This paper analysis the correlation between the external loads, applied to different variable stiffness actuators, and their resultant output stiffness. Different types of variable stiffness actuators have been studied considering springs with different types of nonlinearity. The results provide some insights into how to design the actuator mechanism and nonlinearity of the springs in order to increase the decoupling between the load and stiffness in these actuators. This would significantly widen the application range of a variable stiffness actuator.

  10. Defected red blood cell membranes and direct correlation with the uraemic milieu: the connection with the decreased red blood cell lifespan observed in haemodialysis patients

    International Nuclear Information System (INIS)

    Stamopoulos, D; Manios, E; Gogola, V; Grapsa, E; Bakirtzi, N

    2012-01-01

    Together with impaired production of erythropoietin and iron deficiency, the decreased lifespan of red blood cells (RBCs) is a main factor contributing to the chronic anaemia observed in haemodialysis (HD) patients. Atomic force microscopy is employed in this work to thoroughly survey the membrane of intact RBCs (iRBCs) of HD patients in comparison to those of healthy donors, aiming to obtain direct information on the structural status of RBCs that can be related to their decreased lifespan. We observed that the iRBC membrane of the HD patients is overpopulated with extended circular defects, termed ‘orifices’, that have typical dimension ranging between 0.2 and 1.0 μm. The ‘orifice’ index—that is, the mean population of ‘orifices’ per top membrane surface—exhibits a pronounced relative increase of order 54 ± 12% for the HD patients as compared to healthy donors. Interestingly, for the HD patients, the ‘orifice’ index, which relates to the structural status of the RBC membrane, correlates strongly with urea concentration, which is a basic index of the uraemic milieu. Thus, these results indicate that the uraemic milieu downgrades the structural status of the RBC membrane, possibly triggering biochemical processes that result in their premature elimination from the circulation. This process could decrease the lifespan of RBCs, as observed in HD patients. (paper)

  11. 40 CFR 35.2035 - Rotating biological contractor (RBC) replacement grants.

    Science.gov (United States)

    2010-07-01

    ... treatment works owner, the applicant, its engineers, contractors, equipment manufacturers or suppliers; (b) The RBC failure has significantly increased the project's capital or operation and maintenance costs; (c) The modification/replacement project meets all requirements of EPA's construction grant and other...

  12. Inward cholesterol gradient of the membrane system in P. falciparum-infected erythrocytes involves a dilution effect from parasite-produced lipids

    Directory of Open Access Journals (Sweden)

    Fuyuki Tokumasu

    2014-05-01

    Full Text Available Plasmodium falciparum (Pf infection remodels the human erythrocyte with new membrane systems, including a modified host erythrocyte membrane (EM, a parasitophorous vacuole membrane (PVM, a tubulovesicular network (TVN, and Maurer's clefts (MC. Here we report on the relative cholesterol contents of these membranes in parasitized normal (HbAA and hemoglobin S-containing (HbAS, HbAS erythrocytes. Results from fluorescence lifetime imaging microscopy (FLIM experiments with a cholesterol-sensitive fluorophore show that membrane cholesterol levels in parasitized erythrocytes (pRBC decrease inwardly from the EM, to the MC/TVN, to the PVM, and finally to the parasite membrane (PM. Cholesterol depletion of pRBC by methyl-β-cyclodextrin treatment caused a collapse of this gradient. Lipid and cholesterol exchange data suggest that the cholesterol gradient involves a dilution effect from non-sterol lipids produced by the parasite. FLIM signals from the PVM or PM showed little or no difference between parasitized HbAA vs HbS-containing erythrocytes that differed in lipid content, suggesting that malaria parasites may regulate the cholesterol contents of the PVM and PM independently of levels in the host cell membrane. Cholesterol levels may affect raft structures and the membrane trafficking and sorting functions that support Pf survival in HbAA, HbAS and HbSS erythrocytes.

  13. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    Science.gov (United States)

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  14. Association of n3 and n6 polyunsaturated fatty acids in red blood cell membrane and plasma with severity of normal tension glaucoma

    Directory of Open Access Journals (Sweden)

    Man Yu

    2015-06-01

    Full Text Available AIM:To determine whether red blood cell (RBC membrane and plasma lipids, particularly long-chain polyunsaturated fatty acids such as eicosapentaenoic acid (EPA, docosahexaenoic acid (DHA, arachidonic acid (AA are significantly correlated with severity of normal tension glaucoma (NTG.METHODS:This study included 35 patients with NTG and 12 healthy normal control subjects, matched for age and sex with the study group. The stage of glaucoma was determined according to the Hodapp-Parrish-Anderson classification. Lipids were extracted from RBC membranes and plasma, and fatty acid methyl esters prepared and analyzed by gas chromatography-mass spectrometry (GC-MS.RESULTS:When RBC lipids were analyzed, the levels of EPA, the levels of DHA and the ratio of n3 to n6 were positively associated with the Humphrey Perimetry mean deviation (MD score (r=0.617, P<0.001; r=0.727, P<0.001 and r=0.720, P<0.001, respectively, while the level of AA was negatively associated with the MD score (r=-0.427, P=0.001. When plasma lipids were analyzed, there was a significant positive relationship between the levels of EPA and the MD score (r=0.648, P<0.001, and the levels of AA were inversely correlated with the MD score (r=-0.638, P<0.001.CONCLUSION:The levels of n3 and n6 polyunsaturated fatty acids in RBC membrane and plasma lipids were associated with severity of NTG.

  15. Effects of Hypoxia on Erythrocyte Membrane Properties—Implications for Intravascular Hemolysis and Purinergic Control of Blood Flow

    Directory of Open Access Journals (Sweden)

    Ryszard Grygorczyk

    2017-12-01

    Full Text Available Intravascular hemolysis occurs in hereditary, acquired, and iatrogenic hemolytic conditions but it could be also a normal physiological process contributing to intercellular signaling. New evidence suggests that intravascular hemolysis and the associated release of adenosine triphosphate (ATP may be an important mechanism for in vivo local purinergic signaling and blood flow regulation during exercise and hypoxia. However, the mechanisms that modulate hypoxia-induced RBC membrane fragility remain unclear. Here, we provide an overview of the role of RBC ATP release in the regulation of vascular tone and prevailing assumptions on the putative release mechanisms. We show importance of intravascular hemolysis as a source of ATP for local purinergic regulation of blood flow and discuss processes that regulate membrane propensity to rupture under stress and hypoxia.

  16. Marked increase in rat red blood cell membrane protein glycosylation by one-month treatment with a cafeteria diet

    Directory of Open Access Journals (Sweden)

    Laia Oliva

    2015-07-01

    Full Text Available Background and Objectives. Glucose, an aldose, spontaneously reacts with protein amino acids yielding glycosylated proteins. The compounds may reorganize to produce advanced glycosylation products, which regulatory importance is increasingly being recognized. Protein glycosylation is produced without the direct intervention of enzymes and results in the loss of function. Glycosylated plasma albumin, and glycosylated haemoglobin are currently used as index of mean plasma glucose levels, since higher glucose availability results in higher glycosylation rates. In this study we intended to detect the early changes in blood protein glycosylation elicited by an obesogenic diet.Experimental Design. Since albumin is in constant direct contact with plasma glucose, as are the red blood cell (RBC membranes, we analyzed their degree or glycosylation in female and male rats, either fed a standard diet or subjected to a hyper-energetic self-selected cafeteria diet for 30 days. This model produces a small increase in basal glycaemia and a significant increase in body fat, leaving the animals in the initial stages of development of metabolic syndrome. We also measured the degree of glycosylation of hemoglobin, and the concentration of glucose in contact with this protein, that within the RBC. Glycosylation was measured by colorimetric estimation of the hydroxymethylfurfural liberated from glycosyl residues by incubation with oxalate.Results. Plasma glucose was higher in cafeteria diet and in male rats, both independent effects. However, there were no significant differences induced by sex or diet in either hemoglobin or plasma proteins. Purified RBC membranes showed a marked effect of diet: higher glycosylation in cafeteria rats, which was more marked in females (not in controls. In any case, the number of glycosyl residues per molecule were higher in hemoglobin than in plasma proteins (after correction for molecular weight. The detected levels of glucose in

  17. OroSTIFF: Face-referenced measurement of perioral stiffness in health and disease.

    Science.gov (United States)

    Chu, Shin-Ying; Barlow, Steven M; Kieweg, Douglas; Lee, Jaehoon

    2010-05-28

    A new device and automated measurement technology known as OroSTIFF is described to characterize non-participatory perioral stiffness in healthy adults for eventual application to patients with orofacial movement disorders associated with neuromotor disease, traumatic injury, or congenital clefts of the upper lip. Previous studies of perioral biomechanics required head stabilization for extended periods of time during measurement, which precluded sampling patients with involuntary body/head movements (dyskinesias), or pediatric subjects. The OroSTIFF device is face-referenced and avoids the complications associated with head-restraint. Supporting data of non-participatory perioral tissue stiffness using OroSTIFF are included from 10 male and 10 female healthy subjects. The OroSTIFF device incorporates a pneumatic glass air cylinder actuator instrumented for pressure, and an integrated subminiature displacement sensor to encode lip aperture. Perioral electromyograms were simultaneously sampled to confirm passive muscle state for the superior and inferior divisions of the orbicularis oris muscles. Perioral stiffness, derived as a quotient from resultant force (DeltaF) and interangle span (DeltaX), was modeled with multilevel regression techniques. Real-time calculation of the perioral stiffness function demonstrated a significant quadratic relation between imposed interangle stretch and resultant force. This stiffness growth function also differed significantly between males and females. This study demonstrates the OroSTIFF 'proof-of-concept' for cost-effective non-invasive stimulus generation and derivation of perioral stiffness in a group of healthy unrestrained adults, and a case study to illustrate the dose-dependent effects of Levodopa on perioral stiffness in an individual with advanced Parkinson's disease who exhibited marked dyskinesia and rigidity. Copyright 2010 Elsevier Ltd. All rights reserved.

  18. Deformation analysis of a film-overlapped micro-pump membrane structure

    International Nuclear Information System (INIS)

    Lee, Fu-Shin; Wang, Pi-Wen; Chen, Chih-Hsiung

    2008-01-01

    A novel approach is developed to study a film-overlapped membrane structure. Meanwhile, the established model is employed to design the micro-pump membrane structure and to evaluate its pumping efficiency. Two-dimensional coupling effects between the overlapping actuator films and the deformable membrane are thoroughly investigated, including the influences on the membrane from the overlapping films' elongation effects, Poisson's ratio effects and shear strain effects. Overall deformations and interactions for the three-layer membrane structures are accurately calculated through exercising the developed model, in contrast to what difficulties are usually encountered in carrying out FEM methods with very thin elements meshed for the actuator films. Furthermore, this study demonstrates that the high stiffness of the actuating metal films needs to be reflected in the equivalent stiffness of the membrane structures, especially when the sizes of the actuator films become compatible with the sizes of the membranes. Hence, the optimal micro-pumping efficiency of a membrane structure is acquired upon exercising the developed model, and larger sizes of the actuating films do not definitely obtain larger pumping efficiencies for the electromagnetically actuated micro-pumps

  19. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  20. Epidemiology of RBC Transfusions in Patients With Severe Acute Kidney Injury: Analysis From the Randomized Evaluation of Normal Versus Augmented Level Study.

    Science.gov (United States)

    Bellomo, Rinaldo; Mårtensson, Johan; Kaukonen, Kirsi-Maija; Lo, Serigne; Gallagher, Martin; Cass, Alan; Myburgh, John; Finfer, Simon

    2016-05-01

    To assess the epidemiology and outcomes associated with RBC transfusion in patients with severe acute kidney injury requiring continuous renal replacement therapy. Post hoc analysis of data from a multicenter, randomized, controlled trial. Thirty-five ICUs in Australia and New Zealand. Cohort of 1,465 patients enrolled in the Randomized Evaluation of Normal versus Augmented Level replacement therapy study. Daily information on morning hemoglobin level and amount of RBC transfused were prospectively collected in the Randomized Evaluation of Normal versus Augmented Level study. We analyzed the epidemiology of such transfusions and their association with clinical outcomes. Overall, 977 patients(66.7%) received a total of 1,192 RBC units. By day 5, 785 of 977 transfused patients (80.4%) had received at least one RBC transfusion. Hemoglobin at randomization was lower in transfused than in nontransfused patients (94 vs 111 g/L; p regression analysis, RBC transfusion was independently associated with lower 90-day mortality (hazard ratio, 0.55; 95% CI, 0.38-0.79). However, we found no independent association between RBC transfusions and mortality when the analyses were restricted to patients surviving at least 5 days (hazard ratio, 1.29; 95% CI, 0.90-1.85). We found no independent association between RBC transfusion and renal replacement therapy-free days, mechanical ventilator-free days, or length of stay in ICU or hospital. In patients with severe acute kidney injury treated with continuous renal replacement therapy, we found no association of RBC transfusion with 90-day mortality or other patient-centered outcomes. The optimal hemoglobin threshold for RBC transfusion in such patients needs to be determined in future randomized controlled trials.

  1. Oral supplementation of vitamin E reduces osmotic fragility of RBC in hemolytic anemic patients with G6PD deficiency

    International Nuclear Information System (INIS)

    Sultana, N.; Begum, S.; Begum, N.; Ali, T.

    2009-01-01

    haemolytic anaemia due to G6PD deficiency in comparison to those of the healthy control. After supplementation with vitamin E starting and completing points of osmotic fragility of RBC were significantly decreased whereas, MCV, MCH, MCHC were significantly increased towards those of healthy of healthy control in supplemented group of patients in comparison to those of their pre-supplemented (day-1) and non-supplemented groups both on day 1 and day 60. From this study it may be concluded that, disturbances of some of the haematological parameter like higher osmotic fragility of RBC and lower MCV, MCH, MCHC occur in G6PD deficient haemolytic anaemic patients, which returned towards normal after supplementation of vitamin E, which clearly indicates? the role of this anti-oxidant vitamin in maintaining red cell membrane integrity and thereby decreases the rate of haemolysis in this group of patients. So, vitamin E can be supplemented along with other drugs for better management of the patients. (author)

  2. Development of a kit for RBC labelling with 99mTc and its clinic evaluation

    International Nuclear Information System (INIS)

    Marafuschi, A.M.; Nowotny, G.A.; Palcos, M.C.; Rotta, M. del C.

    1980-01-01

    A kit for labelling red blood cells (RBC) with 99m Tc based on a Tin Pyrophosphate mixture freeze-dried and a saline solution saturated with nitrogen has been prepared for spleen and placenta scanning, circulatory studies and blood volume determinations. The stannous tin is intended to reduce the 99m Tc pertechnetate, obtained either from generators or from solvent extraction, to the appropriate valence state suitable for labelling. The technique is as follows: Add to the heparinized blood sample the Tin-Pyrophosphate mixture dissolved in the saline solution. After five minutes incubation time at room temperature the plasma is discarded by centrifugation. Following the addition of the tracer activity to the separated RBC, the supernatant is discarded after a second centrifugation. Depending on the test to be performed, the RBC are either resuspended in saline solution for blood pool or circulation studies or denaturalized at 49.5 deg C for spleen scanning. The labelling yield (95-88%) and its stability has been checked by in vitro measurements, up to four hours after labelling. The biological distribution and spleen uptake have been determined in rats and rabbits. The developed method proved to be adequate for labelling RBC with good labelling retention. An interesting application is shown in babies with congenital cardiac defects and suspected absence of the spleen, where the scan gave a good image of the existing spleen. (author) [es

  3. Effect of RBC concentrate transfusions on serum ferritin content in children with acute leukaemia.

    Science.gov (United States)

    Bebeshko, V G; Bruslova, E M; Tsvietkova, N M; Iatsemirskii, S M; Puchkareva, T I; Gonchar, L A; Krukovska, V V; Zelinska, A V; Mishchenko, L P

    2013-01-01

    To study the serum ferritin levels in children with acute leukemia, depending on the number of transfusions of RBC concentrate and period of disease. We studied the red blood count, serum iron and ferritin levels in 54 patients with acute leukemia before chemotherapy, at the time of a standardized treatment protocol, and after transfusions of RBC concentrates. In the debute of acute leukemia just before treatment lauch the serum ferritin in 81.5% of children was 2.3-2.5 higher than normal. The need for transfusion of RBC concentrates was higher under serum ferritin level exceeding 500 ng/mL. The association was established between ferritin content and age of the children, variant of acute leukemia and period of the disease. The level of serum ferritin can be used as a marker of ferrokinetic status for timely diagnosis of iron overload in children with acute leukemias and for application of treatment-and-prophylactic actions. Bebeshko V. G., Bruslova K. M., Cvjetkova N. M., Jacemyrskyj S. M., Pushkarova T. I., Gonchar L. O., Krukovska V. V., Zelinska A. V., Mishhenko L. P., 2013.

  4. Multiple and Periodic Measurement of RBC Aggregation and ESR in Parallel Microfluidic Channels under On-Off Blood Flow Control

    Directory of Open Access Journals (Sweden)

    Yang Jun Kang

    2018-06-01

    Full Text Available Red blood cell (RBC aggregation causes to alter hemodynamic behaviors at low flow-rate regions of post-capillary venules. Additionally, it is significantly elevated in inflammatory or pathophysiological conditions. In this study, multiple and periodic measurements of RBC aggregation and erythrocyte sedimentation rate (ESR are suggested by sucking blood from a pipette tip into parallel microfluidic channels, and quantifying image intensity, especially through single experiment. Here, a microfluidic device was prepared from a master mold using the xurography technique rather than micro-electro-mechanical-system fabrication techniques. In order to consider variations of RBC aggregation in microfluidic channels due to continuous ESR in the conical pipette tip, two indices (aggregation index (AI and erythrocyte-sedimentation-rate aggregation index (EAI are evaluated by using temporal variations of microscopic, image-based intensity. The proposed method is employed to evaluate the effect of hematocrit and dextran solution on RBC aggregation under continuous ESR in the conical pipette tip. As a result, EAI displays a significantly linear relationship with modified conventional ESR measurement obtained by quantifying time constants. In addition, EAI varies linearly within a specific concentration of dextran solution. In conclusion, the proposed method is able to measure RBC aggregation under continuous ESR in the conical pipette tip. Furthermore, the method provides multiple data of RBC aggregation and ESR through a single experiment. A future study will involve employing the proposed method to evaluate biophysical properties of blood samples collected from cardiovascular diseases.

  5. Strength and stiffness of uniaxially tensioned reinforced concrete panels subjected to membrane shear. Technical report

    International Nuclear Information System (INIS)

    Hilmy, S.I.; White, R.N.; Gergely, P.

    1982-06-01

    This report presents experimental and analytical results on internal pressurization effects and seismic shear effects in a concrete containment vessel that is cracked by tension in one direction only. The experimental program, which was restricted to 6 in. thick flat specimens with two-way reinforcement, included establishment of (a) extensional stiffness for uniaxially tensioned specimens stressed to 0.6fy, and (b) shear strength and stiffness of these cracked specimens with tension levels ranging from 0 to 0.9fy; values were about 10 to 15 percent higher than in similar biaxially tensioned specimens. Eleven (11) specimens were tested (6 in monotonic shear and 5 in reversing cyclic shear)

  6. Modeling of the axon membrane skeleton structure and implications for its mechanical properties.

    Directory of Open Access Journals (Sweden)

    Yihao Zhang

    2017-02-01

    Full Text Available Super-resolution microscopy recently revealed that, unlike the soma and dendrites, the axon membrane skeleton is structured as a series of actin rings connected by spectrin filaments that are held under tension. Currently, the structure-function relationship of the axonal structure is unclear. Here, we used atomic force microscopy (AFM to show that the stiffness of the axon plasma membrane is significantly higher than the stiffnesses of dendrites and somata. To examine whether the structure of the axon plasma membrane determines its overall stiffness, we introduced a coarse-grain molecular dynamics model of the axon membrane skeleton that reproduces the structure identified by super-resolution microscopy. Our proposed computational model accurately simulates the median value of the Young's modulus of the axon plasma membrane determined by atomic force microscopy. It also predicts that because the spectrin filaments are under entropic tension, the thermal random motion of the voltage-gated sodium channels (Nav, which are bound to ankyrin particles, a critical axonal protein, is reduced compared to the thermal motion when spectrin filaments are held at equilibrium. Lastly, our model predicts that because spectrin filaments are under tension, any axonal injuries that lacerate spectrin filaments will likely lead to a permanent disruption of the membrane skeleton due to the inability of spectrin filaments to spontaneously form their initial under-tension configuration.

  7. Modeling of the axon membrane skeleton structure and implications for its mechanical properties.

    Science.gov (United States)

    Zhang, Yihao; Abiraman, Krithika; Li, He; Pierce, David M; Tzingounis, Anastasios V; Lykotrafitis, George

    2017-02-01

    Super-resolution microscopy recently revealed that, unlike the soma and dendrites, the axon membrane skeleton is structured as a series of actin rings connected by spectrin filaments that are held under tension. Currently, the structure-function relationship of the axonal structure is unclear. Here, we used atomic force microscopy (AFM) to show that the stiffness of the axon plasma membrane is significantly higher than the stiffnesses of dendrites and somata. To examine whether the structure of the axon plasma membrane determines its overall stiffness, we introduced a coarse-grain molecular dynamics model of the axon membrane skeleton that reproduces the structure identified by super-resolution microscopy. Our proposed computational model accurately simulates the median value of the Young's modulus of the axon plasma membrane determined by atomic force microscopy. It also predicts that because the spectrin filaments are under entropic tension, the thermal random motion of the voltage-gated sodium channels (Nav), which are bound to ankyrin particles, a critical axonal protein, is reduced compared to the thermal motion when spectrin filaments are held at equilibrium. Lastly, our model predicts that because spectrin filaments are under tension, any axonal injuries that lacerate spectrin filaments will likely lead to a permanent disruption of the membrane skeleton due to the inability of spectrin filaments to spontaneously form their initial under-tension configuration.

  8. Arabidopsis Pol II-Dependent in Vitro Transcription System Reveals Role of Chromatin for Light-Inducible rbcS Gene Transcription1

    Science.gov (United States)

    Ido, Ayaka; Iwata, Shinya; Iwata, Yuka; Igarashi, Hisako; Hamada, Takahiro; Sonobe, Seiji; Sugiura, Masahiro; Yukawa, Yasushi

    2016-01-01

    In vitro transcription is an essential tool to study the molecular mechanisms of transcription. For over a decade, we have developed an in vitro transcription system from tobacco (Nicotiana tabacum)-cultured cells (BY-2), and this system supported the basic activities of the three RNA polymerases (Pol I, Pol II, and Pol III). However, it was not suitable to study photosynthetic genes, because BY-2 cells have lost their photosynthetic activity. Therefore, Arabidopsis (Arabidopsis thaliana) in vitro transcription systems were developed from green and etiolated suspension cells. Sufficient in vitro Pol II activity was detected after the minor modification of the nuclear soluble extracts preparation method; removal of vacuoles from protoplasts and L-ascorbic acid supplementation in the extraction buffer were particularly effective. Surprisingly, all four Arabidopsis Rubisco small subunit (rbcS-1A, rbcS-1B, rbcS-2B, and rbcS-3B) gene members were in vitro transcribed from the naked DNA templates without any light-dependent manner. However, clear light-inducible transcriptions were observed using chromatin template of rbcS-1A gene, which was prepared with a human nucleosome assembly protein 1 (hNAP1) and HeLa histones. This suggested that a key determinant of light-dependency through the rbcS gene transcription was a higher order of DNA structure (i.e. chromatin). PMID:26662274

  9. Limit cycles and stiffness control with variable stiffness actuators

    NARCIS (Netherlands)

    Carloni, Raffaella; Marconi, L.

    2012-01-01

    Variable stiffness actuators realize highly dynamic systems, whose inherent mechanical compliance can be properly exploited to obtain a robust and energy-efficient behavior. The paper presents a control strategy for variable stiffness actuators with the primarily goal of tracking a limit cycle

  10. RBC acetyl cholinesterase: A poor man′s early diagnostic biomarker for familial alzheimer′s and Parkinson′s disease dementia

    Directory of Open Access Journals (Sweden)

    Himmatrao Saluba Bawaskar

    2015-01-01

    Full Text Available Objective: Analysis of red blood cell acetyl cholinesterase (AChE in a familial Alzheimer′s diseases (AD Parkinson′s disease dementia (PDD and their first generation. Setting: General hospital, Mahad district, Raigad. Patients and Methods: Clinically diagnosed patients of AD and PDD and their asymptomatic relatives. Their blood was collected in EDTA tube and transferred to laboratory at Mumbai. Result: Median red blood cell (RBC cholinesterase levels amongst PDD, their first generation asymptomatic relatives, familial AD, asymptomatic relatives of AD, healthy controls, farmers exposed to pesticides (positive control and other neurological condition without dementia (hypertension with TIA 1, sub-dural hematoma 2, hypothyroid 1, non-familial unilateral parkinsonism without dementia 3, writers cramps 2, hyponitremia 1 and cerebral palsy with non-fluent aphasia 1. Median values of RBC AChE were 19086.78 U/L, 15666.05 U/L, 9013.11 U/L, 7806.19 U/L, 14334.57 U/L, 9785.05 U/L and 13162.60 U/L, respectively. As compared to controls, RBC AChE levels were statistically significant among PDD (P = 0.004 and significantly lowered among familial AD patients (P = 0.010, relatives of patients (P = 0.010. Interpretations: Below the normal RBC AChE level is a potential biomarker in asymptomatic relatives of familial AD patients. RBC AChE is raised than normal level in patients suffering from PDD, where AChE inhibitors are helpful. However, RBC AChE level below the normal where AChE inhibitor may not be effective.

  11. Whole body gamma radiation effects on rheological behaviour (deformability) of rat erythrocytes

    International Nuclear Information System (INIS)

    Soliman, M.S.

    2004-01-01

    This study was designed to determine the effect of whole body gamma irradiation on the rheological behaviour of rat erythrocytes (deformability). Animals were divided into 4 irradiated groups and 4 control groups according to their sacrificing time intervals (1 st, 3 rd, 5 th and 7 th days) post-irradiation with dose (6 Gy). In all animals and at the previous time intervals, red blood cell (RBC) membrane proteins electrophoretic pattern, RBC membrane lipids levels (cholesterol and phospholipids), RBC electrolytes levels (sodium, potassium and calcium), corpuscular osmotic fragility and RBC morphological by scanning electron microscopy were determined. Highly significant increase in membrane cholesterol, RBC sodium, calcium and corpuscular osmotic fragility accompanied by highly significant decrease in membrane phospholipids, RBC potassium and RBC deformability were found. No changes in membrane proteins electrophoretic patterns were detected. Morphologically, there were increase in the incidences of echinocytes and spherocytes development, which were time dependent. According to the previous results, irradiation promotes alterations in RBC shape (echinocytosis), membrane skeletal dysfunction, membrane lipid peroxidation, increase in membrane cholesterol/phospholipid content, changes in membrane electrolyte permeability and decrease then increase in osmotic fragility. These alterations in turn led to decrease in cellular deformability as a result of increased membrane rigidity and also due to cells dehydration caused by excess leakage of potassium ions from the RBCs

  12. Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error.

    Science.gov (United States)

    Chan, Leo Li-Ying; Laverty, Daniel J; Smith, Tim; Nejad, Parham; Hei, Hillary; Gandhi, Roopali; Kuksin, Dmitry; Qiu, Jean

    2013-02-28

    Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs

  13. Growth of plasmodium falciparum in human erythrocytes containing abnormal membrane proteins

    International Nuclear Information System (INIS)

    Schulman, S.; Roth, E.F. Jr.; Cheng, B.; Rybicki, A.C.; Sussman, I.I.; Wong, M.; Nagel, R.L.; Schwartz, R.S.; Wang, W.; Ranney, H.M.

    1990-01-01

    To evaluate the role of erythrocyte (RBC) membrane proteins in the invasion and maturation of Plasmodium falciparum, the authors have studied, in culture, abnormal RBCs containing quantitative or qualitative membrane protein defects. These defects included hereditary spherocytosis (HS) due to decreases in the content of spectrin [HS(Sp + )], hereditary elliptocytosis (HE) due to protein 4.1 deficiency [HE(4.1 0 )], HE due to a spectrin αI domain structural variant that results in increased content of spectrin dimers [HE(Spα I/65 )], and band 3 structural variants. Parasite invasion, measured by the initial uptake of [ 3 H]hypoxanthine 18 hr after inoculation with merozoites, was normal in all of the pathologic RBCs. In contrast, RBCs from six HS(Sp + ) subjects showed marked growth inhibition that became apparent after the first or second growth cycle. The extent of decreased parasite growth in HS(Sp + ) RBCs closely correlated with the extent of RBC spectrin deficiency. Homogeneous subpopulations of dense HS RBCs exhibited decreased parasite growth to the same extent as did HS whole blood. RBCs from four HE subjects showed marked parasite growth and development

  14. Phylogeny and intraspecific variability of holoparasitic Orobanche (Orobanchaceae) inferred from plastid rbcL sequences.

    Science.gov (United States)

    Manen, Jean-François; Habashi, Christine; Jeanmonod, Daniel; Park, Jeong-Mi; Schneeweiss, Gerald M

    2004-11-01

    The rbcL sequences of 106 specimens representing 28 species of the four recognized sections of Orobanche were analyzed and compared. Most sequences represent pseudogenes with premature stop codons. This study confirms that the American lineage (sects. Gymnocaulis and Myzorrhiza) contains potentially functional rbcL-copies with intact open reading frames and low rates of non-synonymous substitutions. For the first time, this is also shown for a member of the Eurasian lineage, O. coerulescens of sect. Orobanche, while all other investigated species of sects. Orobanche and Trionychon contain pseudogenes with distorted reading frames and significantly higher rates of non-synonymous substitutions. Phylogenetic analyses of the rbcL sequences give equivocal results concerning the monophyly of Orobanche, and the American lineage might be more closely related to Boschniakia and Cistanche than to the other sections of Orobanche. Additionally, species of sect. Trionychon phylogenetically nest in sect. Orobanche. This is in concordance with results from other plastid markers (rps2 and matK), but in disagreement with other molecular (nuclear ITS), morphological, and karyological data. This might indicate that the ancestor of sect. Trionychon has captured the plastid genome, or parts of it, of a member of sect. Orobanche. Apart from the phylogenetically problematic position of sect. Trionychon, the phylogenetic relationships within sect. Orobanche are similar to those inferred from nuclear ITS data and are close to the traditional groupings traditionally recognized based on morphology. The intraspecific variation of rbcL is low and is neither correlated with intraspecific morphological variability nor with host range. Ancestral character reconstruction using parsimony suggests that the ancestor of O. sect. Orobanche had a narrow host range.

  15. Antioxidant activity of citrullus colocynthis pulp extract in the RBC's of alloxan-induced diabetic rats

    International Nuclear Information System (INIS)

    Dallak, M.; Jaliah, B.I.

    2010-01-01

    Previous studies in our laboratory showed that Citrullus colocynthis pulp seedless extract have antihyperglycemic and insulinotropic effects in alloxan induced diabetes. Reactive oxygen species have been implicated in the mechanism of damage of red blood cells and anaemia in diabetic patients. So the current study was carried out to investigate the protective role of citrullus colocynthis against oxidative stress in the RBC's of alloxan induced diabetic rats. Methods: Rats were divided into four groups each of ten rats, the first group was normal non diabetic rats given normal saline orally and was named control group, the second group was diabetic rats given normal saline orally and were named normal saline treated-diabetic rats, the third and fourth group were diabetic rats treated with the pulp extract or glibenclamide (a positive control) orally. Evaluations were made for haematological parameters in the blood and for lipid peroxidation and oxidative stress enzymes activities in the RBC's of all experimental rats. Results: The diabetic rats had a significant decrease (p<0.05) in total erythrocytes count and Packed Cell Volume (PCV) and a normal Haemoglobin (Hb) value in the blood. They also showed decreased levels of Thiobarbituric Acid Reactive Substances (TBARS) and decreased activities of Superoxide Dismutase (SOD) and Catalase (CAT) in the RBC's hemolysate. On other hand, oral administration of citrullus colocynthis or glibenclamide alleviated these altered parameters in the treated rats, they resulted in a significant increase (p<0.05) in the in total erythrocytes count and PCV (Haematocrit) values in the blood and caused a significant decreased levels of TBARS and increased activities of SOD and CAT in the RBC's of those diabetic treated rats when compared to diabetic rats given normal saline. The effect was more profound in citrullus colocynthis treated diabetic rats. Conclusion: Citrullus colocynthis pulp extract possesses a potent antioxidant property

  16. Penelitian penentuan konstanta saturasi (Ks pada rbc unit

    Directory of Open Access Journals (Sweden)

    Prayitno Prayitno

    1992-04-01

    Full Text Available Kinetic of Rotating Biological Contractor have been investigated by manu researchers. In general the model emploued either saturation kinetic (following Monod equation or first order kinetic to describe substrate removal. In this experiment, saturation kinetic model was used to find out the saturation constant of the RBC unit. The influent fed into the unit was synthetic waste water with glucose as organic carbon sources. The flow was maintained constant at 20.4 1/d and COD influent resulted the saturation constant (Ks 11.17 mg/I with 20 hours of detention time.

  17. Development of a stiffness-angle law for simplifying the measurement of human hair stiffness.

    Science.gov (United States)

    Jung, I K; Park, S C; Lee, Y R; Bin, S A; Hong, Y D; Eun, D; Lee, J H; Roh, Y S; Kim, B M

    2018-04-01

    This research examines the benefits of caffeine absorption on hair stiffness. To test hair stiffness, we have developed an evaluation method that is not only accurate, but also inexpensive. Our evaluation method for measuring hair stiffness culminated in a model, called the Stiffness-Angle Law, which describes the elastic properties of hair and can be widely applied to the development of hair care products. Small molecules (≤500 g mol -1 ) such as caffeine can be absorbed into hair. A common shampoo containing 4% caffeine was formulated and applied to hair 10 times, after which the hair stiffness was measured. The caffeine absorption of the treated hair was observed using Fourier-transform infrared spectroscopy (FTIR) with a focal plane array (FPA) detector. Our evaluation method for measuring hair stiffness consists of a regular camera and a support for single strands of hair. After attaching the hair to the support, the bending angle of the hair was observed with a camera and measured. Then, the hair strand was weighed. The stiffness of the hair was calculated based on our proposed Stiffness-Angle Law using three variables: angle, weight of hair and the distance the hair was pulled across the support. The caffeine absorption was confirmed by FTIR analysis. The concentration of amide bond in the hair certainly increased due to caffeine absorption. After caffeine was absorbed into the hair, the bending angle and weight of the hair changed. Applying these measured changes to the Stiffness-Angle Law, it was confirmed that the hair stiffness increased by 13.2% due to caffeine absorption. The theoretical results using the Stiffness-Angle Law agree with the visual examinations of hair exposed to caffeine and also the known results of hair stiffness from a previous report. Our evaluation method combined with our proposed Stiffness-Angle Law effectively provides an accurate and inexpensive evaluation technique for measuring bending stiffness of human hair. © 2018

  18. Selection of GP. Mur antigen-negative RBC for blood recipients with anti-'Mia ' records decreases transfusion reaction rates in Taiwan.

    Science.gov (United States)

    Yang, C-A; Lin, J-A; Chang, C-W; Wu, K-H; Yeh, S-P; Ho, C-M; Chang, J-G

    2016-10-01

    To evaluate the clinical significance of GP. Mur antigen-negative blood selection for transfusion in patients with anti-'Mi a ' records. The GP. Mur RBC phenotype is prevalent (7·3%) in Taiwan. Antibodies against GP. Mur (anti-'Mi a ') are identified in 1·24% of our population, and anti-'Mi a ' screening using GP. Mur RBC has been routine for Taiwan's blood banks. However, due to the lack of commercial antibodies, only cross-matching was used to prevent transfusion of GP. Mur-positive blood to patients with anti-'Mi a ' in most hospitals. There is still a risk of GP. Mur-positive RBC exposure and subsequent anti-'Mi a '-related transfusion reactions. Since February 2014, GP. Mur antigen-negative RBCs identified by reaction with anti-'Mi a '-positive serum were selected for blood recipients with anti-'Mi a ' records. The transfusion reactions between January 2013 and January 2014 were compared with those that occurred between February 2014 and July 2015. The transfusion reaction rate was significantly higher in anti-'Mi a '-positive blood recipients compared to total subjects receiving an RBC transfusion before GP. Mur-negative donor RBC selection. After antigen-negative RBC selection, the transfusion reaction frequency in subjects with anti-'Mi a ' became similar to total blood recipients. IgG form anti-'Mi a ' antibodies were present in all cases of probable anti-'Mi a '-related transfusion reactions. The time required for anti-'Mi a ' boosting after transfusion was around 4-21 days. Selection of GP. Mur-negative RBC for transfusion to patients with anti-'Mi a ' records could decrease the rate of transfusion reaction and antibody boosting. This procedure should be incorporated into blood bank routines in areas where anti-'Mi a ' is prevalent. © 2016 British Blood Transfusion Society.

  19. Posttraumatic stiff elbow

    Directory of Open Access Journals (Sweden)

    Ravi Mittal

    2017-01-01

    Full Text Available Posttraumatic stiff elbow is a frequent and disabling complication and poses serious challenges for its management. In this review forty studies were included to know about the magnitude of the problem, causes, pathology, prevention, and treatment of posttraumatic stiff elbow. These studies show that simple measures such as internal fixation, immobilization in extension, and early motion of elbow joint are the most important steps that can prevent elbow stiffness. It also supports conservative treatment in selected cases. There are no clear guidelines about the choice between the numerous procedures described in literature. However, this review article disproves two major beliefs-heterotopic ossification is a bad prognostic feature, and passive mobilization of elbow causes elbow stiffness.

  20. Stiffening of Red Blood Cells Induced by Cytoskeleton Disorders: A Joint Theory-Experiment Study.

    Science.gov (United States)

    Lai, Lipeng; Xu, Xiaofeng; Lim, Chwee Teck; Cao, Jianshu

    2015-12-01

    The functions and elasticities of the cell are largely related to the structures of the cytoskeletons underlying the lipid bilayer. Among various cell types, the red blood cell (RBC) possesses a relatively simple cytoskeletal structure. Underneath the membrane, the RBC cytoskeleton takes the form of a two-dimensional triangular network, consisting of nodes of actins (and other proteins) and edges of spectrins. Recent experiments focusing on the malaria-infected RBCs (iRBCs) show that there is a correlation between the elongation of spectrins in the cytoskeletal network and the stiffening of the iRBCs. Here we rationalize the correlation between these two observations by combining the wormlike chain model for single spectrins and the effective medium theory for the network elasticity. We specifically focus on how the disorders in the cytoskeletal network affect its macroscopic elasticity. Analytical and numerical solutions from our model reveal that the stiffness of the membrane increases with increasing end-to-end distances of spectrins, but has a nonmonotonic dependence on the variance of the end-to-end distance distributions. These predictions are verified quantitatively by our atomic force microscopy and micropipette aspiration measurements of iRBCs. The model may, from a molecular level, provide guidelines for future identification of new treatment methods for RBC-related diseases, such as malaria infection. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  1. Radioiodinated, photoactivatable phosphatidylcholine and phosphatidylserine: transfer properties and differential photoreactive interaction with human erythrocyte membrane proteins

    International Nuclear Information System (INIS)

    Schroit, A.J.; Madsen, J.; Ruoho, A.E.

    1987-01-01

    An isotopically labeled cross-linking reagent, succinimido 3-(3-[ 125 I]iodo-4-azidophenyl)propionate, has been synthesized and coupled to 1-acyl-2-(aminocaproyl)phosphatidylcholine according to previously described procedures. 125 I- and N 3 -labeled phosphatidylserine ( 125 I-N 3 -PS) was produced from the phosphatidylcholine (PC) analog by phospholipase D catalyzed base exchange in the presence of L-serine. These phospholipid analogues are photoactivatable, are labeled with 125 I at high specific activity, completely incorporate into synthetic vesicles, and spontaneously transfer between membranes. When an excess of acceptor vesicles or red blood cells (RBC) was mixed with a population of donor vesicles containing the 125 I-N 3 -phospholipids, approximately 40% of the analogues transferred to the acceptor population. After transfer in the dark to RBC, all of the 125 I-N 3 -PC incorporated into the cells could be removed by washing with serum, whereas the 125 I-N 3 -PS could not. After photolabeling of intact RBC, ∼50% of the PC and 20% of the PS cross-linked to membrane proteins as determined by their insolubility in CHCl 3 /MeOH. Analysis of probe distribution by sodium dodecyl sulfate-polyacrylamide gel electrophoresis revealed that 125 I-N 3 -PS preferentially labeled a M/sub r/ 30,000 peptide which contained ∼30% of the protein-bound label

  2. Piezoelectric Sensor to Measure Soft and Hard Stiffness with High Sensitivity for Ultrasonic Transducers

    Directory of Open Access Journals (Sweden)

    Yan-Rui Li

    2015-06-01

    Full Text Available During dental sinus lift surgery, it is important to monitor the thickness of the remaining maxilla to avoid perforating the sinus membrane. Therefore, a sensor should be integrated into ultrasonic dental tools to prevent undesirable damage. This paper presents a piezoelectric (PZT sensor installed in an ultrasonic transducer to measure the stiffness of high and low materials. Four design types using three PZT ring materials and a split PZT for actuator and sensor ring materials were studied. Three sensor locations were also examined. The voltage signals of the sensor and the displacement of the actuator were analyzed to distinguish the low and high stiffness. Using sensor type T1 made of the PZT-1 material and the front location A1 provided a high sensitivity of 2.47 Vm/kN. The experimental results demonstrated that our design can measure soft and hard stiffness.

  3. Effect of Processing and Storage on RBC function in vivo

    Science.gov (United States)

    Doctor, Allan; Spinella, Phil

    2012-01-01

    Red Blood Cell (RBC) transfusion is indicated to improve oxygen delivery to tissue, and for no other purpose. We have come to appreciate that donor RBCs are fundamentally altered during processing and storage, in a fashion that both impairs oxygen transport efficacy and introduces additional risk by perturbing both immune and coagulation systems. The protean biophysical and physiologic changes in RBC function arising from storage are termed the ‘storage lesion’; many have been understood for some time; for example, we know that the oxygen affinity of stored blood rises during the storage period1 and that intracellular allosteric regulators, notably 2,3-bisphosphoglyceric acid (DPG) and ATP, are depleted during storage. Our appreciation of other storage lesion features has emerged with improved understanding of coagulation, immune and vascular signaling systems. Herein we review key features of the ‘storage lesion’. Additionally, we call particular attention to the newly appreciated role of RBCs in regulating linkage between regional blood flow and regional O2 consumption by regulating the bioavailability of key vasoactive mediators in plasma, as well as discuss how processing and storage disturbs this key signaling function and impairs transfusion efficacy. PMID:22818545

  4. Membrane shape modulates transmembrane protein distribution.

    Science.gov (United States)

    Aimon, Sophie; Callan-Jones, Andrew; Berthaud, Alice; Pinot, Mathieu; Toombes, Gilman E S; Bassereau, Patricia

    2014-01-27

    Although membrane shape varies greatly throughout the cell, the contribution of membrane curvature to transmembrane protein targeting is unknown because of the numerous sorting mechanisms that take place concurrently in cells. To isolate the effect of membrane shape, we used cell-sized giant unilamellar vesicles (GUVs) containing either the potassium channel KvAP or the water channel AQP0 to form membrane nanotubes with controlled radii. Whereas the AQP0 concentrations in flat and curved membranes were indistinguishable, KvAP was enriched in the tubes, with greater enrichment in more highly curved membranes. Fluorescence recovery after photobleaching measurements showed that both proteins could freely diffuse through the neck between the tube and GUV, and the effect of each protein on membrane shape and stiffness was characterized using a thermodynamic sorting model. This study establishes the importance of membrane shape for targeting transmembrane proteins and provides a method for determining the effective shape and flexibility of membrane proteins. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy.

    Science.gov (United States)

    Zink, Stephen I; Ohki, Stephen K; Stein, Barry; Zambuto, Domenic A; Rosenberg, Ronald J; Choi, Jenny J; Tubbs, Daniel S

    2008-10-01

    The purpose of our study was to compare contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning for the evaluation of active lower gastrointestinal bleeding. Over 17 months, 55 patients (32 men, 23 women; age range, 21-92 years) were evaluated prospectively with contrast-enhanced MDCT using 100 mL of iopromide 300 mg I/mL. Technetium-99m-labeled RBC scans were obtained on 41 of 55 patients and select patients underwent angiography for attempted embolization. Each imaging technique was reviewed in a blinded fashion for sensitivity for detection of active bleeding as well as the active lower gastrointestinal bleeding location. Findings were positive on both examinations in eight patients and negative on both examinations in 20 patients. Findings were positive on contrast-enhanced MDCT and negative on (99m)Tc-labeled RBC in two patients; findings were negative on contrast-enhanced MDCT and positive on (99m)Tc-labeled RBC in 11 patients. Statistics showed significant disagreement, with simple agreement = 68.3%, kappa = 0.341, and p = 0.014. Sixteen of 60 (26.7%) contrast-enhanced MDCT scans were positive prospectively, with all accurately localizing the site of bleeding and identification of the underlying lesion in eight of 16 (50%). Nineteen of 41 (46.3%) (99m)Tc-labeled RBC scans were positive. Eighteen of 41 matched patients went on to angiography. In four of these 18 (22.2%) patients, the site of bleeding was confirmed by angiography, but in 14 of 18 (77.8%), the findings were negative. Contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning show significant disagreement for evaluation of active lower gastrointestinal bleeding. Contrast-enhanced MDCT appears effective for detection and localization in cases of active lower gastrointestinal bleeding in which hemorrhage is active at the time of CT.

  6. Arterial stiffness and cognitive impairment.

    Science.gov (United States)

    Li, Xiaoxuan; Lyu, Peiyuan; Ren, Yanyan; An, Jin; Dong, Yanhong

    2017-09-15

    Arterial stiffness is one of the earliest indicators of changes in vascular wall structure and function and may be assessed using various indicators, such as pulse-wave velocity (PWV), the cardio-ankle vascular index (CAVI), the ankle-brachial index (ABI), pulse pressure (PP), the augmentation index (AI), flow-mediated dilation (FMD), carotid intima media thickness (IMT) and arterial stiffness index-β. Arterial stiffness is generally considered an independent predictor of cardiovascular and cerebrovascular diseases. To date, a significant number of studies have focused on the relationship between arterial stiffness and cognitive impairment. To investigate the relationships between specific arterial stiffness parameters and cognitive impairment, elucidate the pathophysiological mechanisms underlying the relationship between arterial stiffness and cognitive impairment and determine how to interfere with arterial stiffness to prevent cognitive impairment, we searched PUBMED for studies regarding the relationship between arterial stiffness and cognitive impairment that were published from 2000 to 2017. We used the following key words in our search: "arterial stiffness and cognitive impairment" and "arterial stiffness and cognitive impairment mechanism". Studies involving human subjects older than 30years were included in the review, while irrelevant studies (i.e., studies involving subjects with comorbid kidney disease, diabetes and cardiac disease) were excluded from the review. We determined that arterial stiffness severity was positively correlated with cognitive impairment. Of the markers used to assess arterial stiffness, a higher PWV, CAVI, AI, IMT and index-β and a lower ABI and FMD were related to cognitive impairment. However, the relationship between PP and cognitive impairment remained controversial. The potential mechanisms linking arterial stiffness and cognitive impairment may be associated with arterial pulsatility, as greater arterial pulsatility

  7. DNA Barcoding the Canadian Arctic Flora: Core Plastid Barcodes (rbcL + matK) for 490 Vascular Plant Species

    Science.gov (United States)

    Saarela, Jeffery M.; Sokoloff, Paul C.; Gillespie, Lynn J.; Consaul, Laurie L.; Bull, Roger D.

    2013-01-01

    Accurate identification of Arctic plant species is critical for understanding potential climate-induced changes in their diversity and distributions. To facilitate rapid identification we generated DNA barcodes for the core plastid barcode loci (rbcL and matK) for 490 vascular plant species, representing nearly half of the Canadian Arctic flora and 93% of the flora of the Canadian Arctic Archipelago. Sequence recovery was higher for rbcL than matK (93% and 81%), and rbcL was easier to recover than matK from herbarium specimens (92% and 77%). Distance-based and sequence-similarity analyses of combined rbcL + matK data discriminate 97% of genera, 56% of species, and 7% of infraspecific taxa. There is a significant negative correlation between the number of species sampled per genus and the percent species resolution per genus. We characterize barcode variation in detail in the ten largest genera sampled (Carex, Draba, Festuca, Pedicularis, Poa, Potentilla, Puccinellia, Ranunculus, Salix, and Saxifraga) in the context of their phylogenetic relationships and taxonomy. Discrimination with the core barcode loci in these genera ranges from 0% in Salix to 85% in Carex. Haplotype variation in multiple genera does not correspond to species boundaries, including Taraxacum, in which the distribution of plastid haplotypes among Arctic species is consistent with plastid variation documented in non-Arctic species. Introgression of Poa glauca plastid DNA into multiple individuals of P. hartzii is problematic for identification of these species with DNA barcodes. Of three supplementary barcode loci (psbA–trnH, psbK–psbI, atpF–atpH) collected for a subset of Poa and Puccinellia species, only atpF–atpH improved discrimination in Puccinellia, compared with rbcL and matK. Variation in matK in Vaccinium uliginosum and rbcL in Saxifraga oppositifolia corresponds to variation in other loci used to characterize the phylogeographic histories of these Arctic-alpine species. PMID

  8. Estimating Gear Teeth Stiffness

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2013-01-01

    The estimation of gear stiffness is important for determining the load distribution between the gear teeth when two sets of teeth are in contact. Two factors have a major influence on the stiffness; firstly the boundary condition through the gear rim size included in the stiffness calculation...... and secondly the size of the contact. In the FE calculation the true gear tooth root profile is applied. The meshing stiffness’s of gears are highly non-linear, it is however found that the stiffness of an individual tooth can be expressed in a linear form assuming that the contact length is constant....

  9. RBC-/Cr-51/ half-life and albumin turnover in growing Beagle dogs during chronic radial acceleration

    Science.gov (United States)

    Beckman, D. A.; Evans, J. W.; Oyama, J.

    1979-01-01

    The effects of chronic centrifugation on growing Beagle dogs exposed to -2 or -2.6 Gx on albumin and RBC turnover rates, albumin concentration and space, and total blood volume were determined and compared with caged and run control of animals. Albumin-(I-125) and autologous RBC-(Cr-51) preparations were injected into all dogs at day 82 of the centrifugation periods, and the disappearance curves were determined by successive bleedings of the animals over the next 35 d, during which the centrifugation was continued. There were no differences in albumin turnover rates or space. Two populations of RBCs were found in both centrifugated groups, one with a normal half-life of 27 + or - 1 S.E.M. d, and one with a significantly (p less than 0.01) shorter half-life of 15 + or - 2 S.E.M. d. An absolute polycythemia was also observed in both centrifuged groups. The results suggest that chronic centrifugation acts through some as-yet unknown mechanism to affect RBC population kinetics.

  10. Trabecular meshwork stiffness in glaucoma.

    Science.gov (United States)

    Wang, Ke; Read, A Thomas; Sulchek, Todd; Ethier, C Ross

    2017-05-01

    Alterations in stiffness of the trabecular meshwork (TM) may play an important role in primary open-angle glaucoma (POAG), the second leading cause of blindness. Specifically, certain data suggest an association between elevated intraocular pressure (IOP) and increased TM stiffness; however, the underlying link between TM stiffness and IOP remains unclear and requires further study. We here first review the literature on TM stiffness measurements, encompassing various species and based on a number of measurement techniques, including direct approaches such as atomic force microscopy (AFM) and uniaxial tension tests, and indirect methods based on a beam deflection model. We also briefly review the effects of several factors that affect TM stiffness, including lysophospholipids, rho-kinase inhibitors, cytoskeletal disrupting agents, dexamethasone (DEX), transforming growth factor-β 2 (TGF-β 2 ), nitric oxide (NO) and cellular senescence. We then describe a method we have developed for determining TM stiffness measurement in mice using a cryosection/AFM-based approach, and present preliminary data on TM stiffness in C57BL/6J and CBA/J mouse strains. Finally, we investigate the relationship between TM stiffness and outflow facility between these two strains. The method we have developed shows promise for further direct measurements of mouse TM stiffness, which may be of value in understanding mechanistic relations between outflow facility and TM biomechanical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Effects of an elastic membrane on tube waves in permeable formations

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Johnson, D

    1996-10-01

    In this paper, the modified properties were calculated for tube wave propagation in a fluid-filled borehole penetrating a permeable rock due to the presence of a mudcake which forms on the borehole wall. The mudcake was characterized by an impermeable elastic layer. The mudcake partial sealing mechanism was simulated using a finite membrane stiffness. Consequently, it was shown that the mudcake can reduce, but not eliminate, the permeability effects on the tube wave slowness and attenuation. Moreover, this paper discusses a variety of values for the relevant parameters especially the mudcake thickness and membrane stiffness. The important combinations of mudcake parameters were clarified by using an analytic expression for the low-frequency limit.

  12. Artificial muscles with adjustable stiffness

    International Nuclear Information System (INIS)

    Mutlu, Rahim; Alici, Gursel

    2010-01-01

    This paper reports on a stiffness enhancement methodology based on using a suitably designed contact surface with which cantilevered-type conducting polymer bending actuators are in contact during operation. The contact surface constrains the bending behaviour of the actuators. Depending on the topology of the contact surface, the resistance of the polymer actuators to deformation, i.e. stiffness, is varied. As opposed to their predecessors, these polymer actuators operate in air. Finite element analysis and modelling are used to quantify the effect of the contact surface on the effective stiffness of a trilayer cantilevered beam, which represents a one-end-free, the-other-end-fixed polypyrrole (PPy) conducting polymer actuator under a uniformly distributed load. After demonstrating the feasibility of the adjustable stiffness concept, experiments were conducted to determine the stiffness of bending-type conducting polymer actuators in contact with a range (20–40 mm in radius) of circular contact surfaces. The numerical and experimental results presented demonstrate that the stiffness of the actuators can be varied using a suitably profiled contact surface. The larger the radius of the contact surface is, the higher is the stiffness of the polymer actuators. The outcomes of this study suggest that, although the stiffness of the artificial muscles considered in this study is constant for a given geometric size, and electrical and chemical operation conditions, it can be changed in a nonlinear fashion to suit the stiffness requirement of a considered application. The stiffness enhancement methodology can be extended to other ionic-type conducting polymer actuators

  13. A variable stiffness joint with electrospun P(VDF-TrFE-CTFE) variable stiffness springs

    NARCIS (Netherlands)

    Carloni, Raffaella; Lapp, Valerie I.; Cremonese, Andrea; Belcari, Juri; Zucchelli, Andrea

    This letter presents a novel rotational variable stiffness joint that relies on one motor and a set of variable stiffness springs. The variable stiffness springs are leaf springs with a layered design, i.e., an electro-active layer of electrospun aligned nanofibers of poly(vinylidene

  14. Pharmacological modulation of arterial stiffness.

    LENUS (Irish Health Repository)

    Boutouyrie, Pierre

    2011-09-10

    Arterial stiffness has emerged as an important marker of cardiovascular risk in various populations and reflects the cumulative effect of cardiovascular risk factors on large arteries, which in turn is modulated by genetic background. Arterial stiffness is determined by the composition of the arterial wall and the arrangement of these components, and can be studied in humans non-invasively. Age and distending pressure are two major factors influencing large artery stiffness. Change in arterial stiffness with drugs is an important endpoint in clinical trials, although evidence for arterial stiffness as a therapeutic target still needs to be confirmed. Drugs that independently affect arterial stiffness include antihypertensive drugs, mostly blockers of the renin-angiotensin-aldosterone system, hormone replacement therapy and some antidiabetic drugs such as glitazones. While the quest continues for \\'de-stiffening drugs\\

  15. Mammalian Auditory Hair Cell Bundle Stiffness Affects Frequency Tuning by Increasing Coupling along the Length of the Cochlea.

    Science.gov (United States)

    Dewey, James B; Xia, Anping; Müller, Ulrich; Belyantseva, Inna A; Applegate, Brian E; Oghalai, John S

    2018-06-05

    The stereociliary bundles of cochlear hair cells convert mechanical vibrations into the electrical signals required for auditory sensation. While the stiffness of the bundles strongly influences mechanotransduction, its influence on the vibratory response of the cochlear partition is unclear. To assess this, we measured cochlear vibrations in mutant mice with reduced bundle stiffness or with a tectorial membrane (TM) that is detached from the sensory epithelium. We found that reducing bundle stiffness decreased the high-frequency extent and sharpened the tuning of vibratory responses obtained postmortem. Detaching the TM further reduced the high-frequency extent of the vibrations but also lowered the partition's resonant frequency. Together, these results demonstrate that the bundle's stiffness and attachment to the TM contribute to passive longitudinal coupling in the cochlea. We conclude that the stereociliary bundles and TM interact to facilitate passive-wave propagation to more apical locations, possibly enhancing active-wave amplification in vivo. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.

  16. 浮萍中一个新rbcS基因启动子的克隆及分析%Analysis of a Novel rbcS Promoter Cloned in Duckweed

    Institute of Scientific and Technical Information of China (English)

    王友如

    2010-01-01

    为了分离组织特异性、诱导性的启动子,本研究根据新克隆的浮萍rbcS基因序列设计引物,采用改进的5'walking技术从浮萍基因组中克隆了一个新的rbcS基因启动子,命名为SSU5C基因启动子.序列分析表明:SSU5C基因启动子长度为1 543 bp,含有保守性元件TATA和CAAT box,并且含有水杨酸、脱落酸、赤霉素、茉莉酸甲酯等植物激素和葡萄糖等的保守顺式作用元件.In silico分析初步推测SSU5C基因启动子受多种信号途径的协调调控.

  17. Decision Tree Algorithm-Generated Single-Nucleotide Polymorphism Barcodes of rbcL Genes for 38 Brassicaceae Species Tagging.

    Science.gov (United States)

    Yang, Cheng-Hong; Wu, Kuo-Chuan; Chuang, Li-Yeh; Chang, Hsueh-Wei

    2018-01-01

    DNA barcode sequences are accumulating in large data sets. A barcode is generally a sequence larger than 1000 base pairs and generates a computational burden. Although the DNA barcode was originally envisioned as straightforward species tags, the identification usage of barcode sequences is rarely emphasized currently. Single-nucleotide polymorphism (SNP) association studies provide us an idea that the SNPs may be the ideal target of feature selection to discriminate between different species. We hypothesize that SNP-based barcodes may be more effective than the full length of DNA barcode sequences for species discrimination. To address this issue, we tested a r ibulose diphosphate carboxylase ( rbcL ) S NP b arcoding (RSB) strategy using a decision tree algorithm. After alignment and trimming, 31 SNPs were discovered in the rbcL sequences from 38 Brassicaceae plant species. In the decision tree construction, these SNPs were computed to set up the decision rule to assign the sequences into 2 groups level by level. After algorithm processing, 37 nodes and 31 loci were required for discriminating 38 species. Finally, the sequence tags consisting of 31 rbcL SNP barcodes were identified for discriminating 38 Brassicaceae species based on the decision tree-selected SNP pattern using RSB method. Taken together, this study provides the rational that the SNP aspect of DNA barcode for rbcL gene is a useful and effective sequence for tagging 38 Brassicaceae species.

  18. Contínua evolução da RBC: um obrigado a todos os colaboradores!

    Directory of Open Access Journals (Sweden)

    Bruno Telles

    2017-07-01

    Full Text Available Desde de seu nascimento, a RBC prima pela divulgação do conhecimento pericial tecnicamente validado e pela discussão de novos métodos e de casos. É o caminho que há de ser constantemente trilhado pelos profissionais da perícia para que não eivem seus laudos periciais e pareceres técnicos de vícios insanáveis cujas consequências seriam nefastas para a justiça. Não é à toa que o Corpo Editorial da RBC, com o imprescindível auxílio dos editores de sessão e dos avaliadores, não envida esforços na contínua evolução da revista em direção à qualidade. Prova disso é a permanente busca por indexação em vários meios e pela elevação dos índices de qualidade por qualificação externa. A RBC aparece no Latindex, no CrossRef, no Google Scholar, no Research Gate, no Directory of Open Access Journals (DOAJ, no Electronic Journal Library (EZ3, no Scilit, no Diadorim, na ABEC Brasil, na Universitäts Bibliothek UBL Leipzig e na Qualis/CAPES.

  19. Cholesterol-dependent energy transfer between fluorescent proteins-insights into protein proximity of APP and BACE1 in different membranes in Niemann-Pick type C disease cells.

    Science.gov (United States)

    von Einem, Bjoern; Weber, Petra; Wagner, Michael; Malnar, Martina; Kosicek, Marko; Hecimovic, Silva; Arnim, Christine A F von; Schneckenburger, Herbert

    2012-11-26

    Förster resonance energy transfer (FRET) -based techniques have recently been applied to study the interactions between β-site APP-cleaving enzyme-GFP (BACE1-GFP) and amyloid precursor protein-mRFP (APP-mRFP) in U373 glioblastoma cells. In this context, the role of APP-BACE1 proximity in Alzheimer's disease (AD) pathogenesis has been discussed. FRET was found to depend on intracellular cholesterol levels and associated alterations in membrane stiffness. Here, NPC1 null cells (CHO-NPC1-/-), exhibiting increased cholesterol levels and disturbed cholesterol transport similar to that observed in Niemann-Pick type C disease (NPC), were used to analyze the influence of altered cholesterol levels on APP-BACE1 proximity. Fluorescence lifetime measurements of whole CHO-wild type (WT) and CHO-NPC1-/- cells (EPI-illumination microscopy), as well as their plasma membranes (total internal reflection fluorescence microscopy, TIRFM), were performed. Additionally, generalized polarization (GP) measurements of CHO-WT and CHO-NPC1-/- cells incubated with the fluorescence marker laurdan were performed to determine membrane stiffness of plasma- and intracellular-membranes. CHO-NPC1-/- cells showed higher membrane stiffness at intracellular- but not plasma-membranes, equivalent to cholesterol accumulation in late endosomes/lysosomes. Along with higher membrane stiffness, the FRET efficiency between BACE1-GFP and APP-mRFP was reduced at intracellular membranes, but not within the plasma membrane of CHO-NPC1-/-. Our data show that FRET combined with TIRF is a powerful technique to determine protein proximity and membrane fluidity in cellular models of neurodegenerative diseases.

  20. Measurement and Treatment of Passive Muscle Stiffness

    DEFF Research Database (Denmark)

    Kirk, Henrik

    , which aimed to investigate: 1) The development of a clinical method to evaluate and distinguish neural (reflex mediated stiffness) and non-neural (passive muscle stiffness) components of muscle stiffness in adults with CP by objective and reliable measurements. 2) The association between increased...... and reliability of the method, and argue for the use of the method in the clinical practice. The device is able to distinguish between passive muscle stiffness and reflex-mediated stiffness in subjects with CP. It shows good high intrarater and interrater reliability in evaluation of passive muscle stiffness...... to measure muscle stiffness, and distinguish between passive muscle stiffness and reflex-mediated stiffness. Furthermore, it is a reliable device to measure changes in passive ROM. Treatment of passive muscle stiffness should be directed towards intense training, comprising many repetitions with a functional...

  1. 77 FR 50487 - Application To Export Electric Energy; RBC Energy Services LP

    Science.gov (United States)

    2012-08-21

    ... DEPARTMENT OF ENERGY [OE Docket No. EA-328-A] Application To Export Electric Energy; RBC Energy... electric energy from the United States to Canada pursuant to section 202(e) of the Federal Power Act (FPA... to transmit electric energy from the United States to Canada as a power marketer for a five-year term...

  2. Transversal stiffness of fibers and desmin content in leg muscles of rats under gravitational unloading of various durations.

    Science.gov (United States)

    Ogneva, I V

    2010-12-01

    The aim of this research was the analysis of structural changes in various parts of the sarcolemma and contractile apparatus of muscle fibers by measuring their transversal stiffness by atomic force microscopy under gravitational unloading. Soleus, medial gastrocnemius, and tibialis anterior muscles of Wistar rats were the objects of the study. Gravitational unloading was carried out by antiorthostatic suspension of hindlimbs for 1, 3, 7, and 12 days. It was shown that the transversal stiffness of different parts of the contractile apparatus of soleus muscle fibers decreases during gravitational unloading in the relaxed, calcium-activated, and rigor states, the fibers of the medial gastrocnemius show no changes, whereas the transversal stiffness of tibialis anterior muscle increases. Thus the transversal stiffness of the sarcolemma in the relaxed state is reduced in all muscles, which may be due to the direct action of gravity as an external mechanical factor that can influence the tension on a membrane. The change of sarcolemma stiffness in activated fibers, which is due probably to the transfer of tension from the contractile apparatus, correlates with the dynamics of changes in the content of desmin.

  3. On gear tooth stiffness evaluation

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard; Jørgensen, Martin Felix

    2014-01-01

    The estimation of gear stiffness is important for determining the load distribution between the gear teeth when two sets of teeth are in contact. Two factors have a major influence on the stiffness; firstly the boundary condition through the gear rim size included in the stiffness calculation...

  4. Quantum statistical mechanics of nonrelativistic membranes: crumpling transition at finite temperature

    Science.gov (United States)

    Borelli, M. E. S.; Kleinert, H.; Schakel, Adriaan M. J.

    2000-03-01

    The effect of quantum fluctuations on a nearly flat, nonrelativistic two-dimensional membrane with extrinsic curvature stiffness and tension is investigated. The renormalization group analysis is carried out in first-order perturbative theory. In contrast to thermal fluctuations, which soften the membrane at large scales and turn it into a crumpled surface, quantum fluctuations are found to stiffen the membrane, so that it exhibits a Hausdorff dimension equal to two. The large-scale behavior of the membrane is further studied at finite temperature, where a nontrivial fixed point is found, signaling a crumpling transition.

  5. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear...... viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three...

  6. Erythrocyte swelling and membrane hole formation in hypotonic media as studied by conductometry.

    Science.gov (United States)

    Pribush, A; Meyerstein, D; Hatskelzon, L; Kozlov, V; Levi, I; Meyerstein, N

    2013-02-01

    Hypoosmotic swelling of erythrocytes and the formation of membrane holes were studied by measuring the dc conductance (G). In accordance with the theoretical predictions, these processes are manifested by a decrease in G followed by its increase. Thus, unlike the conventional osmotic fragility test, the proposed methodological approach allows investigations of both the kinetics of swelling and the erythrocyte fragility. It is shown that the initial rate of swelling and the equilibrium size of the cells are affected by the tonicity of a hypotonic solution and the membrane rheological properties. Because the rupture of biological membranes is a stochastic process, a time-dependent increase in the conductance follows an integral distribution function of the membrane lifetime. The main conclusion which stems from reported results is that information about rheological properties of red blood cell (RBC) membranes and the resistivity of RBCs to a certain osmotic shock may be extracted from conductance signals.

  7. Erythrocyte survival studies in lymphomas : a prognostic appraisal. [/sup 51/Cr-labelled RBC

    Energy Technology Data Exchange (ETDEWEB)

    Sanyal, B; Subrahmanyam, K; Pant, G C [Banaras Hindu Univ. (India). Inst. of Medical Sciences

    1977-08-01

    Erythrocyte survival studies using /sup 51/Cr-labelled RBC's were conducted using 20 patients with Hodgkin's lymphoma and 10 control subjects. Hepatic, splenic, and cardiac areas were monitored for rapid detection of hypersplenism. The findings are discussed in relation to the prognosis of the disease in the patients.

  8. Molecular cloning of human protein 4.2: A major component of the erythrocyte membrane

    International Nuclear Information System (INIS)

    Sung, L.A.; Chien, Shu; Lambert, K.; Chang, Longsheng; Bliss, S.A.; Bouhassira, E.E.; Nagel, R.L.; Schwartz, R.S.; Rybicki, A.C.

    1990-01-01

    Protein 4.2 (P4.2) comprises ∼5% of the protein mass of human erythrocyte (RBC) membranes. Anemia occurs in patients with RBCs deficient in P4.2, suggesting a role for this protein in maintaining RBC stability and integrity. The authors now report the molecular cloning and characterization of human RBC P4.2 cDNAs. By immunoscreening a human reticulocyte cDNA library and by using the polymerase chain reaction, two cDNA sequences of 2.4 and 2.5 kilobases (kb) were obtained. These cDNAs differ only by a 90-base-air insert in the longer isoform located three codons downstream from the putative initiation site. The 2.4- and 2.5-kb cDNAs predict proteins of ∼77 and ∼80 kDa, respectively, and the authenticity was confirmed by sequence identity with 46 amino acids of three cyanogen bromide-cleaved peptides of P4.2. Northern blot analysis detected a major 2.4-kb RNA species in reticulocytes. Isolation of two P4.2 cDNAs implies existence of specific regulation of P4.2 expression in human RBCs. Human RBC P4.2 has significant homology with human factor XIII subunit a and guinea pig liver transglutaminase. Sequence alignment of P4.2 with these two transglutaminases, however, revealed that P4.2 lacks the critical cysteine residue required for the enzymatic crosslinking of substrates

  9. LSODE, 1. Order Stiff or Non-Stiff Ordinary Differential Equations System Initial Value Problems

    International Nuclear Information System (INIS)

    Hindmarsh, A.C.; Petzold, L.R.

    2005-01-01

    1 - Description of program or function: LSODE (Livermore Solver for Ordinary Differential Equations) solves stiff and non-stiff systems of the form dy/dt = f. In the stiff case, it treats the Jacobian matrix df/dy as either a dense (full) or a banded matrix, and as either user-supplied or internally approximated by difference quotients. It uses Adams methods (predictor-corrector) in the non-stiff case, and Backward Differentiation Formula (BDF) methods (the Gear methods) in the stiff case. The linear systems that arise are solved by direct methods (LU factor/solve). The LSODE source is commented extensively to facilitate modification. Both a single-precision version and a double-precision version are available. 2 - Methods: It is assumed that the ODEs are given explicitly, so that the system can be written in the form dy/dt = f(t,y), where y is the vector of dependent variables, and t is the independent variable. LSODE contains two variable-order, variable- step (with interpolatory step-changing) integration methods. The first is the implicit Adams or non-stiff method, of orders one through twelve. The second is the backward differentiation or stiff method (or BDF method, or Gear's method), of orders one through five. 3 - Restrictions on the complexity of the problem: The differential equations must be given in explicit form, i.e., dy/dt = f(y,t). Problems with intermittent high-speed transients may cause inefficient or unstable performance

  10. Molecular evolution of rbcL in three gymnosperm families: identifying adaptive and coevolutionary patterns

    LENUS (Irish Health Repository)

    Sen, Lin

    2011-06-03

    Abstract Background The chloroplast-localized ribulose-1, 5-biphosphate carboxylase\\/oxygenase (Rubisco), the primary enzyme responsible for autotrophy, is instrumental in the continual adaptation of plants to variations in the concentrations of CO2. The large subunit (LSU) of Rubisco is encoded by the chloroplast rbcL gene. Although adaptive processes have been previously identified at this gene, characterizing the relationships between the mutational dynamics at the protein level may yield clues on the biological meaning of such adaptive processes. The role of such coevolutionary dynamics in the continual fine-tuning of RbcL remains obscure. Results We used the timescale and phylogenetic analyses to investigate and search for processes of adaptive evolution in rbcL gene in three gymnosperm families, namely Podocarpaceae, Taxaceae and Cephalotaxaceae. To understand the relationships between regions identified as having evolved under adaptive evolution, we performed coevolutionary analyses using the software CAPS. Importantly, adaptive processes were identified at amino acid sites located on the contact regions among the Rubisco subunits and on the interface between Rubisco and its activase. Adaptive amino acid replacements at these regions may have optimized the holoenzyme activity. This hypothesis was pinpointed by evidence originated from our analysis of coevolution that supported the correlated evolution between Rubisco and its activase. Interestingly, the correlated adaptive processes between both these proteins have paralleled the geological variation history of the concentration of atmospheric CO2. Conclusions The gene rbcL has experienced bursts of adaptations in response to the changing concentration of CO2 in the atmosphere. These adaptations have emerged as a result of a continuous dynamic of mutations, many of which may have involved innovation of functional Rubisco features. Analysis of the protein structure and the functional implications of such

  11. Endogenous sphingomyelin segregates into submicrometric domains in the living erythrocyte membrane[S

    Science.gov (United States)

    Carquin, Mélanie; Pollet, Hélène; Veiga-da-Cunha, Maria; Cominelli, Antoine; Van Der Smissen, Patrick; N’kuli, Francisca; Emonard, Hervé; Henriet, Patrick; Mizuno, Hideaki; Courtoy, Pierre J.; Tyteca, Donatienne

    2014-01-01

    We recently reported that trace insertion of exogenous fluorescent (green BODIPY) analogs of sphingomyelin (SM) into living red blood cells (RBCs), partially spread onto coverslips, labels submicrometric domains, visible by confocal microscopy. We here extend this feature to endogenous SM, upon binding of a SM-specific nontoxic (NT) fragment of the earthworm toxin, lysenin, fused to the red monomeric fluorescent protein, mCherry [construct named His-mCherry-NT-lysenin (lysenin*)]. Specificity of lysenin* binding was verified with composition-defined liposomes and by loss of 125I-lysenin* binding to erythrocytes upon SM depletion by SMase. The 125I-lysenin* binding isotherm indicated saturation at 3.5 × 106 molecules/RBC, i.e., ∼3% of SM coverage. Nonsaturating lysenin* concentration also labeled sub­micrometric domains on the plasma membrane of partially spread erythrocytes, colocalizing with inserted green BODIPY-SM, and abrogated by SMase. Lysenin*-labeled domains were stable in time and space and were regulated by temperature and cholesterol. The abundance, size, positioning, and segregation of lysenin*-labeled domains from other lipids (BODIPY-phosphatidylcholine or -glycosphingolipids) depended on membrane tension. Similar lysenin*-labeled domains were evidenced in RBCs gently suspended in 3D-gel. Taken together, these data demonstrate submicrometric compartmentation of endogenous SM at the membrane of a living cell in vitro, and suggest it may be a genuine feature of erythrocytes in vivo. PMID:24826836

  12. Integrated investigation approach for determining mechanical properties of poly-silicon membranes

    OpenAIRE

    Brueckner, J.; Dehe, A.; Auerswald, E.; Dudek, R.; Michel, B.; Rzepka, S.

    2014-01-01

    A methodology is presented for determining mechanical properties of free-standing thin films such as poly-silicon membranes. The integrated investigation approach comprises test structure development, mechanical testing, and numerical simulation. All membrane test structures developed and manufactured consist of the same material but have different stiffness due to variations in the geometric design. The mechanical tests apply microscopic loads utilizing a nanoindentation tool. Young's modulu...

  13. Properties and determination of the interface stiffness

    International Nuclear Information System (INIS)

    Du Danxu; Zhang Hao; Srolovitz, David J.

    2007-01-01

    The chemical potential of a curved interface contains a term that is proportional to the product of the interface curvature and the interface stiffness. In crystalline materials, the interface stiffness is a tensor. This paper examines several basic issues related to the properties of the interface stiffness, especially the determination of the interface stiffness in particular directions (i.e. the commonly used scalar form of the interface stiffness). Of the five parameters that describe an arbitrary grain boundary, only those describing the inclination are crucial for the scalar stiffness. We also examine the influence of crystal symmetry on the stiffness tensor for both free surfaces and grain boundaries. This results in substantial simplifications for cases in which interfaces possess mirror or rotational symmetries. An efficient method for determining the interface stiffness tensor using atomistic simulations is proposed

  14. A Novel Variable Stiffness Mechanism Capable of an Infinite Stiffness Range and Unlimited Decoupled Output Motion

    Directory of Open Access Journals (Sweden)

    Stefan Groothuis

    2014-06-01

    Full Text Available In this paper, a novel variable stiffness mechanism is presented, which is capable of achieving an output stiffness with infinite range and an unlimited output motion, i.e., the mechanism output is completely decoupled from the rotor motion, in the zero stiffness configuration. The mechanism makes use of leaf springs, which are engaged at different positions by means of two movable supports, to realize the variable output stiffness. The Euler–Bernoulli leaf spring model is derived and validated through experimental data. By shaping the leaf springs, it is shown that the stiffness characteristic of the mechanism can be changed to fulfill different application requirements. Alternative designs can achieve the same behavior with only one leaf spring and one movable support pin.

  15. Stiffness of desiccating insect wings

    International Nuclear Information System (INIS)

    Mengesha, T E; Vallance, R R; Mittal, R

    2011-01-01

    The stiffness of insect wings is typically determined through experimental measurements. Such experiments are performed on wings removed from insects. However, the wings are subject to desiccation which typically leads to an increase in their stiffness. Although this effect of desiccation is well known, a comprehensive study of the rate of change in stiffness of desiccating insect wings would be a significant aid in planning experiments as well as interpreting data from such experiments. This communication presents a comprehensive experimental analysis of the change in mass and stiffness of gradually desiccating forewings of Painted Lady butterflies (Vanessa cardui). Mass and stiffness of the forewings of five butterflies were simultaneously measured every 10 min over a 24 h period. The averaged results show that wing mass declined exponentially by 21.1% over this time period with a time constant of 9.8 h, while wing stiffness increased linearly by 46.2% at a rate of 23.4 μN mm -1 h -1 . For the forewings of a single butterfly, the experiment was performed over a period of 1 week, and the results show that wing mass declined exponentially by 52.2% with a time constant of 30.2 h until it reached a steady-state level of 2.00 mg, while wing stiffness increased exponentially by 90.7% until it reached a steady-state level of 1.70 mN mm -1 . (communication)

  16. Stiffness of desiccating insect wings

    Energy Technology Data Exchange (ETDEWEB)

    Mengesha, T E; Vallance, R R [Department of Mechanical Engineering, The George Washington University, 738 Phillips Hall, 801 22nd St NW, Washington, DC 20052 (United States); Mittal, R, E-mail: vallance@gwu.edu [Department of Mechanical Engineering, Johns Hopkins University, 126 Latrobe Hall, 3400 N Charles Street, Baltimore, MD 21218 (United States)

    2011-03-15

    The stiffness of insect wings is typically determined through experimental measurements. Such experiments are performed on wings removed from insects. However, the wings are subject to desiccation which typically leads to an increase in their stiffness. Although this effect of desiccation is well known, a comprehensive study of the rate of change in stiffness of desiccating insect wings would be a significant aid in planning experiments as well as interpreting data from such experiments. This communication presents a comprehensive experimental analysis of the change in mass and stiffness of gradually desiccating forewings of Painted Lady butterflies (Vanessa cardui). Mass and stiffness of the forewings of five butterflies were simultaneously measured every 10 min over a 24 h period. The averaged results show that wing mass declined exponentially by 21.1% over this time period with a time constant of 9.8 h, while wing stiffness increased linearly by 46.2% at a rate of 23.4 {mu}N mm{sup -1} h{sup -1}. For the forewings of a single butterfly, the experiment was performed over a period of 1 week, and the results show that wing mass declined exponentially by 52.2% with a time constant of 30.2 h until it reached a steady-state level of 2.00 mg, while wing stiffness increased exponentially by 90.7% until it reached a steady-state level of 1.70 mN mm{sup -1}. (communication)

  17. Shoulder Stiffness : Current Concepts and Concerns

    NARCIS (Netherlands)

    Itoi, Eiji; Arce, Guillermo; Bain, Gregory I.; Diercks, Ronald L.; Guttmann, Dan; Imhoff, Andreas B.; Mazzocca, Augustus D.; Sugaya, Hiroyuki; Yoo, Yon-Sik

    Shoulder stiffness can be caused by various etiologies such as immobilization, trauma, or surgical interventions. The Upper Extremity Committee of ISAKOS defined the term "frozen shoulder" as idiopathic stiff shoulder, that is, without a known cause. Secondary stiff shoulder is a term that should be

  18. Fractional order models of viscoelasticity as an alternative in the analysis of red blood cell (RBC) membrane mechanics.

    Science.gov (United States)

    Craiem, Damian; Magin, Richard L

    2010-01-20

    New lumped-element models of red blood cell mechanics can be constructed using fractional order generalizations of springs and dashpots. Such 'spring-pots' exhibit a fractional order viscoelastic behavior that captures a wide spectrum of experimental results through power-law expressions in both the time and frequency domains. The system dynamics is fully described by linear fractional order differential equations derived from first order stress-strain relationships using the tools of fractional calculus. Changes in the composition or structure of the membrane are conveniently expressed in the fractional order of the model system. This approach provides a concise way to describe and quantify the biomechanical behavior of membranes, cells and tissues.

  19. The link between exercise and titin passive stiffness.

    Science.gov (United States)

    Lalande, Sophie; Mueller, Patrick J; Chung, Charles S

    2017-09-01

    What is the topic of this review? This review focuses on how in vivo and molecular measurements of cardiac passive stiffness can predict exercise tolerance and how exercise training can reduce cardiac passive stiffness. What advances does it highlight? This review highlights advances in understanding the relationship between molecular (titin-based) and in vivo (left ventricular) passive stiffness, how passive stiffness modifies exercise tolerance, and how exercise training may be therapeutic for cardiac diseases with increased passive stiffness. Exercise can help alleviate the negative effects of cardiovascular disease and cardiovascular co-morbidities associated with sedentary behaviour; this may be especially true in diseases that are associated with increased left ventricular passive stiffness. In this review, we discuss the inverse relationship between exercise tolerance and cardiac passive stiffness. Passive stiffness is the physical property of cardiac muscle to produce a resistive force when stretched, which, in vivo, is measured using the left ventricular end diastolic pressure-volume relationship or is estimated using echocardiography. The giant elastic protein titin is the major contributor to passive stiffness at physiological muscle (sarcomere) lengths. Passive stiffness can be modified by altering titin isoform size or by post-translational modifications. In both human and animal models, increased left ventricular passive stiffness is associated with reduced exercise tolerance due to impaired diastolic filling, suggesting that increased passive stiffness predicts reduced exercise tolerance. At the same time, exercise training itself may induce both short- and long-term changes in titin-based passive stiffness, suggesting that exercise may be a treatment for diseases associated with increased passive stiffness. Direct modification of passive stiffness to improve exercise tolerance is a potential therapeutic approach. Titin passive stiffness itself may

  20. Efficient Method for Calculating the Composite Stiffness of Parabolic Leaf Springs with Variable Stiffness for Vehicle Rear Suspension

    Directory of Open Access Journals (Sweden)

    Wen-ku Shi

    2016-01-01

    Full Text Available The composite stiffness of parabolic leaf springs with variable stiffness is difficult to calculate using traditional integral equations. Numerical integration or FEA may be used but will require computer-aided software and long calculation times. An efficient method for calculating the composite stiffness of parabolic leaf springs with variable stiffness is developed and evaluated to reduce the complexity of calculation and shorten the calculation time. A simplified model for double-leaf springs with variable stiffness is built, and a composite stiffness calculation method for the model is derived using displacement superposition and material deformation continuity. The proposed method can be applied on triple-leaf and multileaf springs. The accuracy of the calculation method is verified by the rig test and FEA analysis. Finally, several parameters that should be considered during the design process of springs are discussed. The rig test and FEA analytical results indicate that the calculated results are acceptable. The proposed method can provide guidance for the design and production of parabolic leaf springs with variable stiffness. The composite stiffness of the leaf spring can be calculated quickly and accurately when the basic parameters of the leaf spring are known.

  1. Hydration Status Is Associated with Aortic Stiffness, but Not with Peripheral Arterial Stiffness, in Chronically Hemodialysed Patients

    Directory of Open Access Journals (Sweden)

    Daniel Bia

    2015-01-01

    Full Text Available Background. Adequate fluid management could be essential to minimize high arterial stiffness observed in chronically hemodialyzed patients (CHP. Aim. To determine the association between body fluid status and central and peripheral arterial stiffness levels. Methods. Arterial stiffness was assessed in 65 CHP by measuring the pulse wave velocity (PWV in a central arterial pathway (carotid-femoral and in a peripheral pathway (carotid-brachial. A blood pressure-independent regional arterial stiffness index was calculated using PWV. Volume status was assessed by whole-body multiple-frequency bioimpedance. Patients were first observed as an entire group and then divided into three different fluid status-related groups: normal, overhydration, and dehydration groups. Results. Only carotid-femoral stiffness was positively associated (P<0.05 with the hydration status evaluated through extracellular/intracellular fluid, extracellular/Total Body Fluid, and absolute and relative overhydration. Conclusion. Volume status and overload are associated with central, but not peripheral, arterial stiffness levels with independence of the blood pressure level, in CHP.

  2. Fractional order models of viscoelasticity as an alternative in the analysis of red blood cell (RBC) membrane mechanics

    International Nuclear Information System (INIS)

    Craiem, Damian; Magin, Richard L

    2010-01-01

    New lumped-element models of red blood cell mechanics can be constructed using fractional order generalizations of springs and dashpots. Such 'spring-pots' exhibit a fractional order viscoelastic behavior that captures a wide spectrum of experimental results through power-law expressions in both the time and frequency domains. The system dynamics is fully described by linear fractional order differential equations derived from first order stress–strain relationships using the tools of fractional calculus. Changes in the composition or structure of the membrane are conveniently expressed in the fractional order of the model system. This approach provides a concise way to describe and quantify the biomechanical behavior of membranes, cells and tissues. (perspective)

  3. Rheological and electrical properties of polymeric nanoparticle solutions and their influence on RBC suspensions

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Koseva, N.; Kowalczyk, A.; Říha, Pavel; Ivanov, I.

    2014-01-01

    Roč. 24, č. 3 (2014), s. 35190 ISSN 1430-6395 Institutional support: RVO:67985874 Keywords : nanoparticles and RBC suspensions * poly(acrylic acid) * rheology * electrical conductivity Subject RIV: BK - Fluid Dynamics Impact factor: 1.078, year: 2014 http://www.ar.ethz.ch/TMPPDF/24308140293.696/ApplRheol_24_35190.pdf

  4. VCODE, Ordinary Differential Equation Solver for Stiff and Non-Stiff Problems

    International Nuclear Information System (INIS)

    Cohen, Scott D.; Hindmarsh, Alan C.

    2001-01-01

    1 - Description of program or function: CVODE is a package written in ANSI standard C for solving initial value problems for ordinary differential equations. It solves both stiff and non stiff systems. In the stiff case, it includes a variety of options for treating the Jacobian of the system, including dense and band matrix solvers, and a preconditioned Krylov (iterative) solver. 2 - Method of solution: Integration is by Adams or BDF (Backward Differentiation Formula) methods, at user option. Corrector iteration is by functional iteration or Newton iteration. For the solution of linear systems within Newton iteration, users can select a dense solver, a band solver, a diagonal approximation, or a preconditioned Generalized Minimal Residual (GMRES) solver. In the dense and band cases, the user can supply a Jacobian approximation or let CVODE generate it internally. In the GMRES case, the pre-conditioner is user-supplied

  5. Simulator for training operators of electric substation: an approach via RBC-Paraconsistent; Simulador para treinamento de operadores de subestacao eletrica: um enfoque via RBC-paraconsistente

    Energy Technology Data Exchange (ETDEWEB)

    Lambert-Torres, G.; Martins, H.G.; Coutinho, M.P.; Goulart, J.D.C.; Soares, F.M.A. [Universidade Federal de Itajuba (UNIFEI), MG (Brazil). Dept. de Engenharia Eletrica], Emails: germanoltorres@gmail.com, helgagonzaga@gmail.com, maurilio.coutinho@gmail.com, janaina157@yahoo.com.br, francis.azevedo@gmail.com

    2009-07-01

    This article presents a combination of two techniques applied artificial intelligence to solve problems to Restoration of an Electric Substation: Casebased Reasoning - CBR and the Four Values Annotated Paraconsistent Logic - 4vAPL. The process occurs in the connection functions of belief, disbelief, specialty and temporality to LPA4v in the retrieval of cases to determine process diagnostic of an RBC. The field of CBR is applied in a recovery of an electric substation. The LPA4v is the support applied in problems that have inconsistent information, partials and undefined. Thus this study is closer of the real situations.

  6. Wrinkling reduction of membrane structure by trimming edges

    Directory of Open Access Journals (Sweden)

    Mingjun Liu

    2017-05-01

    Full Text Available Thin membranes have negligible bending stiffness, compressive stresses inevitably lead to wrinkling. Therefore, it is important to keep the surface of membrane structures flat in order to guarantee high precision. Edge-trimming is an effective method to passively diminish wrinkles, however a key difficulty in this process is the determination of the optimal trimming level. In this paper, regular polygonal membrane structures subjected to equal radial forces were analyzed, and a new stress field distribution model for arc-edge square membrane structure was proposed to predict the optimal trimming level. This model is simple and applicable to any polygonal membrane structures. Comparison among the results of the finite element analysis, and the experimental and analytical results showed that the proposed model accurately described the stress field distribution and guaranteed that there are no wrinkles appear inside the effective inscribed circle region for the optimal trimming level.

  7. Effects of fiber density and plasma modification of nanofibrous membranes on the adhesion and growth of HaCaT keratinocytes.

    Science.gov (United States)

    Bacakova, Marketa; Lopot, Frantisek; Hadraba, Daniel; Varga, Marian; Zaloudkova, Margit; Stranska, Denisa; Suchy, Tomas; Bacakova, Lucie

    2015-01-01

    It may be possible to regulate the cell colonization of biodegradable polymer nanofibrous membranes by plasma treatment and by the density of the fibers. To test this hypothesis, nanofibrous membranes of different fiber densities were treated by oxygen plasma with a range of plasma power and exposure times. Scanning electron microscopy and mechanical tests showed significant modification of nanofibers after plasma treatment. The intensity of the fiber modification increased with plasma power and exposure time. The exposure time seemed to have a stronger effect on modifying the fiber. The mechanical behavior of the membranes was influenced by the plasma treatment, the fiber density, and their dry or wet state. Plasma treatment increased the membrane stiffness; however, the membranes became more brittle. Wet membranes displayed significantly lower stiffness than dry membranes. X-ray photoelectron spectroscopy (XPS) analysis showed a slight increase in oxygen-containing groups on the membrane surface after plasma treatment. Plasma treatment enhanced the adhesion and growth of HaCaT keratinocytes on nanofibrous membranes. The cells adhered and grew preferentially on membranes of lower fiber densities, probably due to the larger area of void spaces between the fibers. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. Real-Time Vision-Based Stiffness Mapping †.

    Science.gov (United States)

    Faragasso, Angela; Bimbo, João; Stilli, Agostino; Wurdemann, Helge Arne; Althoefer, Kaspar; Asama, Hajime

    2018-04-26

    This paper presents new findings concerning a hand-held stiffness probe for the medical diagnosis of abnormalities during palpation of soft-tissue. Palpation is recognized by the medical community as an essential and low-cost method to detect and diagnose disease in soft-tissue. However, differences are often subtle and clinicians need to train for many years before they can conduct a reliable diagnosis. The probe presented here fills this gap providing a means to easily obtain stiffness values of soft tissue during a palpation procedure. Our stiffness sensor is equipped with a multi degree of freedom (DoF) Aurora magnetic tracker, allowing us to track and record the 3D position of the probe whilst examining a tissue area, and generate a 3D stiffness map in real-time. The stiffness probe was integrated in a robotic arm and tested in an artificial environment representing a good model of soft tissue organs; the results show that the sensor can accurately measure and map the stiffness of a silicon phantom embedded with areas of varying stiffness.

  9. Real-Time Vision-Based Stiffness Mapping †

    Directory of Open Access Journals (Sweden)

    Angela Faragasso

    2018-04-01

    Full Text Available This paper presents new findings concerning a hand-held stiffness probe for the medical diagnosis of abnormalities during palpation of soft-tissue. Palpation is recognized by the medical community as an essential and low-cost method to detect and diagnose disease in soft-tissue. However, differences are often subtle and clinicians need to train for many years before they can conduct a reliable diagnosis. The probe presented here fills this gap providing a means to easily obtain stiffness values of soft tissue during a palpation procedure. Our stiffness sensor is equipped with a multi degree of freedom (DoF Aurora magnetic tracker, allowing us to track and record the 3D position of the probe whilst examining a tissue area, and generate a 3D stiffness map in real-time. The stiffness probe was integrated in a robotic arm and tested in an artificial environment representing a good model of soft tissue organs; the results show that the sensor can accurately measure and map the stiffness of a silicon phantom embedded with areas of varying stiffness.

  10. Dynamic stiffness of suction caissons - vertical vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    The dynamic response of offshore wind turbines are affected by the properties of the foundation and the subsoil. The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three-dimensional coupled Boundary Element/Finite Element model. Comparisons are made with known analytical and numerical solutions in order to evaluate the static and dynamic behaviour of the Boundary Element/Finite Element model. The vertical frequency dependent stiffness has been determined for different combinations of the skirt length, Poisson's ratio and the ratio between soil stiffness and skirt stiffness. Finally the dynamic behaviour at high frequencies is investigated. (au)

  11. RBC-coupled tPA prevents cerebrovasodilatory impairment and tissue injury in pediatric cerebral hypoxia/ischemia through inhibition of ERK MAPK unregulation

    Energy Technology Data Exchange (ETDEWEB)

    Ganguly, Kumkum [Los Alamos National Laboratory; Armstead, William M [U PENNSYLVANIA; Kiessling, J W [U PENNSYLVANIA; Chen, Xiao - Han [U PENNSYLVANIA; Smith, Douglas H [U PENNSYLVANA; Higazi, Abd Ar [U PENNSYLVANIA; Cines, Douglas B [U PENNSYLVANIA; Bdeir, Khalil [U PENNSYLVANIA; Zaitsev, Sergei [U PENNSYLVANIA; Muzykantov, Vladimir R [U PENNSYLVANIA

    2008-01-01

    Babies experience hypoxia (H) and ischemia (I) from stroke. The only approved treatment for stroke is fibrinolytic therapy with tissue-type plasminogen activator (tPA). However, tPA potentiates H/I-induced impairment of responses to cerebrovasodilators such as hypercapnia and hypotension, and blockade of tPA-mediated vasoactivity prevents this deleterious effect. Coupling tPA to RBCs reduces its CNS toxicity through spatially confining the drug to the vasculature. Mitogen activated protein kinase (MAPK), a family of at least 3 kinases, is upregulated after H/I. In this study we determined if RBC-tPA given before or after cerebral H/I would preserve responses to cerebrovasodilators and prevent neuronal injury mediated through the ERK MAPK pathway. Animals given RBC-tPA maintained responses to cerebrovasodilators at levels equivalent to pre-H/I values. CSF and brain parenchymal ERK MAPK was elevated by H/I and this upregulation was potentiated by tPA, but blunted by RBC-tPA. U 0126, an ERK MAPK antagonist, also maintained cerebrovasodilation post H/I. Neuronal degeneration in CA1 hippocampus and parietal cortex after H/I was exacerbated by tPA, but ameliorated by RBC-tPA and U 0126. These data suggest that coupling tPA to RBCs may offer a novel approach towards increasing the benefit/risk ratio of thrombolytic therapy for CNS disorders associated with H/I.

  12. Time dependent variation of human blood conductivity as a method for an estimation of RBC aggregation

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2008-01-01

    Roč. 39, č. 1 (2008), s. 69-78 ISSN 1386-0291 Institutional research plan: CEZ:AV0Z20600510 Keywords : RBC aggregation * blood conductivity * low shear rate viscometry Subject RIV: BO - Biophysics Impact factor: 1.814, year: 2008

  13. Fin Ray Stiffness and Fin Morphology Control Ribbon-Fin-Based Propulsion.

    Science.gov (United States)

    Liu, Hanlin; Taylor, Bevan; Curet, Oscar M

    2017-06-01

    Ribbon-fin-based propulsion has rich locomotor capabilities that can enhance the mobility and performance of underwater vehicles navigating in complex environments. Bony fishes using this type of propulsion send one or multiple traveling waves along an elongated fin with the actuation of highly flexible rays that are interconnected by an elastic membrane. In this work, we study how the use of flexible rays and different morphology can affect the performance of ribbon-fin propulsion. We developed a physical model composed of 15 rays that are interconnected with an elastic membrane. We tested four different ray flexural stiffness and four aspect ratios. The robotic model was tested in a low-turbulence flume under two flow conditions ([Formula: see text] wavelength/s). In two experimental sets, we measured fin kinematics, net surge forces, and power consumption. Using these data, we perform a thrust and power analysis of the undulating fin. We present the thrust coefficient, power coefficient, and propulsive efficiency. We find that the thrust generation was linear with the enclosed area swept by the fin, and square of the relative velocity between the incoming flow and traveling wave. The thrust coefficient levels off around 0.5. In addition, for our parameter range, we find that the power consumption scales by the cube of the effective tangential velocity of the rays [Formula: see text] (A is the amplitude of the ray oscillating motion, and [Formula: see text] is the angular velocity). We show that a decay in stiffness decreases both thrust production and power consumption. However, for rays with high flexural stiffness, the difference in thrust compared with rigid rays is minimal. Moreover, our results show that flexible rays can improve the propulsive efficiency compared with a rigid counterpart. Finally, we find that the morphology of ribbon fin affects its propulsive efficiency. For the aspect ratio considered in our experiments, [Formula: see text] was the most

  14. Observer-Based Human Knee Stiffness Estimation.

    Science.gov (United States)

    Misgeld, Berno J E; Luken, Markus; Riener, Robert; Leonhardt, Steffen

    2017-05-01

    We consider the problem of stiffness estimation for the human knee joint during motion in the sagittal plane. The new stiffness estimator uses a nonlinear reduced-order biomechanical model and a body sensor network (BSN). The developed model is based on a two-dimensional knee kinematics approach to calculate the angle-dependent lever arms and the torques of the muscle-tendon-complex. To minimize errors in the knee stiffness estimation procedure that result from model uncertainties, a nonlinear observer is developed. The observer uses the electromyogram (EMG) of involved muscles as input signals and the segmental orientation as the output signal to correct the observer-internal states. Because of dominating model nonlinearities and nonsmoothness of the corresponding nonlinear functions, an unscented Kalman filter is designed to compute and update the observer feedback (Kalman) gain matrix. The observer-based stiffness estimation algorithm is subsequently evaluated in simulations and in a test bench, specifically designed to provide robotic movement support for the human knee joint. In silico and experimental validation underline the good performance of the knee stiffness estimation even in the cases of a knee stiffening due to antagonistic coactivation. We have shown the principle function of an observer-based approach to knee stiffness estimation that employs EMG signals and segmental orientation provided by our own IPANEMA BSN. The presented approach makes realtime, model-based estimation of knee stiffness with minimal instrumentation possible.

  15. Modulation of erythrocyte membrane mechanical stability by 2,3-diphosphoglycerate in the neonatal poikilocytosis/elliptocytosis syndrome.

    OpenAIRE

    Mentzer, W C; Iarocci, T A; Mohandas, N; Lane, P A; Smith, B; Lazerson, J; Hays, T

    1987-01-01

    To explain the transient anemia and poikilocytosis seen during infancy in hereditary elliptocytosis (HE), we resealed erythrocyte (RBC) ghosts from affected children or their elliptocytic parents with 2,3-diphosphoglycerate (DPG) (0-8 mM), a compound that dissociates membrane skeletons, then measured ghost mechanical stability in the ektacytometer. Without added 2,3-DPG, ghost mechanical stability was subnormal in infantile poikilocytosis (IP) and HE but was even more abnormal in hereditary p...

  16. Optimization of a quasi-zero-stiffness isolator

    International Nuclear Information System (INIS)

    Carrella, A.; Brennan, M. J.; Waters, T. P.

    2007-01-01

    The frequency range over which a mount can isolate a mass from a vibrating base (or vice versa) is often limited by the mount stiffness required to support the weight of the mass. This compromise can be made more favourable by employing non-linear mounts with a softening spring characteristic such that small excursions about the static equilibrium position result in small dynamic spring forces and a correspondingly low natural frequency. This paper concerns the force-displacement characteristic of a so-called quasi-zero-stiffness (QZS) mechanism which is characterised by an appreciable static stiffness but very small (theoretically zero) dynamic stiffness. The mechanism studied comprises a vertical spring acting in parallel with two further springs which, when inclined at an appropriate angle to the vertical, produce a cancelling negative stiffness effect. Analysis of the system shows that a QZS characteristic can be obtained if the systems parameters (angle of inclination and ratio of spring stiffness) are opportunely chosen. By introducing the additional criterion that the displacement of the system be largest without exceeding a desired (low) value of stiffness an optimal set of parameter values is derived. Under sufficiently large displacements the stiffness of the QZS mechanism can eventually exceed that of the simple mass-spring system and criteria for this detrimental scenario to arise are presented

  17. Transversal stiffness and beta-actin and alpha-actinin-4 content of the M. soleus fibers in the conditions of a 3-day reloading after 14-day gravitational unloading.

    Science.gov (United States)

    Ogneva, I V

    2011-01-01

    The aim of the work was to analyze the structural changes in different parts of the sarcolemma and contractile apparatus of muscle fibers by measuring their transversal stiffness by atomic force microscopy in a three-day reloading after a 14-day gravity disuse, which was carried out by hind-limbs suspension. The object of the study was the soleus muscle of the Wistar rat. It was shown that after 14 days of disuse, there was a reduction of transversal stiffness of all points of the sarcolemma and contractile apparatus. Readaptation for 3 days leads to complete recovery of the values of the transversal stiffness of the sarcolemma and to partial value recovery of the contractile apparatus. The changes in transversal stiffness of sarcolemma correlate with beta-actin and alpha-actinin-4 in membrane protein fractions.

  18. Experimental method for the study of blood and RBC suspension conductivity under flow

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2014-01-01

    Roč. 67, č. 7 (2014), s. 995-1004 ISSN 1310-1331 Grant - others:The Ministry of Education and Science of Bulgaria(BG) BG051PO001-3.3-05/0001; The Ministry of Education, Youth and Science of Bulgaria(BG) DO-805/2012 Institutional support: RVO:67985874 Keywords : viscometric flow * conductivity * blood/RBC suspension microstructural changes Subject RIV: BK - Fluid Dynamics Impact factor: 0.284, year: 2014

  19. rbcL gene sequences provide evidence for the evolutionary lineages of leptosporangiate ferns.

    OpenAIRE

    Hasebe, M; Omori, T; Nakazawa, M; Sano, T; Kato, M; Iwatsuki, K

    1994-01-01

    Pteriodophytes have a longer evolutionary history than any other vascular land plant and, therefore, have endured greater loss of phylogenetically informative information. This factor has resulted in substantial disagreements in evaluating characters and, thus, controversy in establishing a stable classification. To compare competing classifications, we obtained DNA sequences of a chloroplast gene. The sequence of 1206 nt of the large subunit of the ribulose-bisphosphate carboxylase gene (rbc...

  20. Constitutive Modelling of Resins in the Stiffness Domain

    Science.gov (United States)

    Klasztorny, M.

    2004-09-01

    An analytic method for inverting the constitutive compliance equations of viscoelasticity for resins is developed. These equations describe the HWKK/H rheological model, which makes it possible to simulate, with a good accuracy, short-, medium- and long-term viscoelastic processes in epoxy and polyester resins. These processes are of first-rank reversible isothermal type. The time histories of deviatoric stresses are simulated with three independent strain history functions of fractional and normal exponential types. The stiffness equations are described by two elastic and six viscoelastic constants having a clear physic meaning (three long-term relaxation coefficients and three relaxation times). The time histories of axiatoric stresses are simulated as perfectly elastic. The inversion method utilizes approximate constitutive stiffness equations of viscoelasticity for the HWKK/H model. The constitutive compliance equations for the model are a basis for determining the exact complex shear stiffness, whereas the approximate constitutive stiffness equations are used for determining the approximate complex shear stiffness. The viscoelastic constants in the stiffness domain are derived by equating the exact and approximate complex shear stiffnesses. The viscoelastic constants are obtained for Epidian 53 epoxy and Polimal 109 polyester resins. The accuracy of the approximate constitutive stiffness equations are assessed by comparing the approximate and exact complex shear stiffnesses. The constitutive stiffness equations for the HWKK/H model are presented in uncoupled (shear/bulk) and coupled forms. Formulae for converting the constants of shear viscoelasticity into the constants of coupled viscoelasticity are given as well.

  1. Grape extract protects against γ-radiation-induced membrane damage strains of human erythrocytes

    International Nuclear Information System (INIS)

    Das, Subir Kumar

    2017-01-01

    The membrane integrity of circulating red blood cells (RBCs) is compromised by the deleterious actions of γ-radiation in humans. Grapes are the richest source of antioxidants due to presence of potentially bioactive phytochemicals. The objective of the present study was to assess the radioprotective actions of grape extracts against the γ-radiation-induced membrane permeability of human erythrocytes. The scavenging activities in seeds of grape in DPPH, hydrogen peroxide and hydroxyl radicals, were higher than skin or pulp of different cultivars. Grape extracts also showed appreciable extent of total antioxidant capacity and effective antihemolytic action. Grape extracts significantly ameliorated the γ-radiation-induced increase of the levels of thiobarbituric acid-reactive substances (TBARS, an index of lipid peroxidation) in the RBC membrane ghosts. Stored blood showed higher levels of K + ion as compared to the normal blood which was elevated by γ-radiation. Membrane ATPase was inhibited by the exposure to γ-radiation.Treatment of RBCs with the grape extracts prior to the exposure of γ-radiation significantly mitigated these changes in the erythrocyte membranes caused by the lower dose of radiation (4 Gy). (author)

  2. The stiffness change and the increase in the ultimate capacity for a stiff pile resulting from a cyclic loading

    DEFF Research Database (Denmark)

    Lada, Aleksandra; Ibsen, Lars Bo; Nicolai, Giulio

    In the paper the experimental results of small-scale tests on a stiff monopile are presented to outline the change in stiffness during the cyclic loading and the change in the ultimate pile capacity. The results confirm the increase of stiffness and the increase in bearing capacity resulting from...

  3. Analytical study of a quasi-zero stiffness coupling using a torsion magnetic spring with negative stiffness

    Science.gov (United States)

    Zheng, Yisheng; Zhang, Xinong; Luo, Yajun; Zhang, Yahong; Xie, Shilin

    2018-02-01

    By now, many translation quasi-zero stiffness (QZS) mechanisms have been proposed to overcome the restriction between the isolation frequency range and the load bearing capacity of linear isolators. The couplings of rotor systems undertake the functions of transmitting static driving torque and isolating disturbing torque simultaneously, which creates the demand of torsion QZS mechanisms. Hence a QZS coupling is presented in this paper, where a torsion magnetic spring (TMS) composed of two coaxial ring magnet arrangements in repulsive configuration is employed to produce negative torsion stiffness to counteract the positive stiffness of a rubber spring. In this paper, the expressions of magnetic torque and stiffness are given firstly and verified by finite element simulations; and the effect of geometric parameters of the TMS on its stiffness characteristic is analyzed in detail, which contributes to the optimal design of the TMS. Then dynamic analysis of the QZS coupling is performed and the analytical expression of the torque transmissibility is achieved based on the Harmonic Balance Method. Finally, simulation of the torque transmissibility is carried out to reveal how geometric parameters of the TMS affect the isolation performance.

  4. Lack of Aquaporin 3 in bovine erythrocyte membranes correlates with low glycerol permeation.

    Science.gov (United States)

    Campos, Elisa; Moura, Teresa F; Oliva, Abel; Leandro, Paula; Soveral, Graça

    2011-05-13

    In general, erythrocytes are highly permeable to water, urea and glycerol. However, expression of aquaporin isoforms in erythrocytes appears to be species characteristic. In the present study, human (hRBC) and bovine (bRBC) erythrocytes were chosen for comparative studies due to their significant difference in membrane glycerol permeability. Osmotic water permeability (P(f)) at 23°C was (2.89 ± 0.37) × 10(-2) and (5.12 ± 0.61) × 10(-2)cms(-1) for human and bovine cells, respectively, with similar activation energies for water transport. Glycerol permeability (P(gly)) for human ((1.37 ± 0.26) × 10(-5)cms(-1)) differed in three orders of magnitude from bovine erythrocytes ((5.82 ± 0.37) × 10(-8)cms(-1)) that also showed higher activation energy for glycerol transport. When compared to human, bovine erythrocytes showed a similar expression pattern of AQP1 glycosylated forms on immunoblot analysis, though in slight higher levels, which could be correlated with the 1.5-fold larger P(f) found. However, AQP3 expression was not detectable. Immunofluorescence analysis confirmed the absence of AQP3 expression in bovine erythrocyte membranes. In conclusion, lack of AQP3 in bovine erythrocytes points to the lipid pathway as responsible for glycerol permeation and explains the low glycerol permeability and high E(a) for transport observed in ruminants. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Stiffness of Railway Soil-Steel Structures

    Directory of Open Access Journals (Sweden)

    Machelski Czesław

    2015-12-01

    Full Text Available The considerable influence of the soil backfill properties and that of the method of compacting it on the stiffness of soil-steel structures is characteristic of the latter. The above factors (exhibiting randomness become apparent in shell deformation measurements conducted during construction and proof test loading. A definition of soil-shell structure stiffness, calculated on the basis of shell deflection under the service load, is proposed in the paper. It is demonstrated that the stiffness is the inverse of the deflection influence function used in structural mechanics. The moving load methodology is shown to be useful for testing, since it makes it possible to map the shell deflection influence line also in the case of group loads (concentrated forces, as in bridges. The analyzed cases show that the shell’s span, geometry (static scheme and the height of earth fill influence the stiffness of the structure. The soil-steel structure’s characteristic parameter in the form of stiffness k is more suitable for assessing the quality of construction works than the proposed in code geometric index ω applied to beam structures. As shown in the given examples, parameter k is more effective than stiffness parameter λ used to estimate the deformation of soil-steel structures under construction. Although the examples concern railway structures, the methodology proposed in the paper is suitable also for road bridges.

  6. Stiffness of Railway Soil-Steel Structures

    Science.gov (United States)

    Machelski, Czesław

    2015-12-01

    The considerable influence of the soil backfill properties and that of the method of compacting it on the stiffness of soil-steel structures is characteristic of the latter. The above factors (exhibiting randomness) become apparent in shell deformation measurements conducted during construction and proof test loading. A definition of soil-shell structure stiffness, calculated on the basis of shell deflection under the service load, is proposed in the paper. It is demonstrated that the stiffness is the inverse of the deflection influence function used in structural mechanics. The moving load methodology is shown to be useful for testing, since it makes it possible to map the shell deflection influence line also in the case of group loads (concentrated forces), as in bridges. The analyzed cases show that the shell's span, geometry (static scheme) and the height of earth fill influence the stiffness of the structure. The soil-steel structure's characteristic parameter in the form of stiffness k is more suitable for assessing the quality of construction works than the proposed in code geometric index ω applied to beam structures. As shown in the given examples, parameter k is more effective than stiffness parameter λ used to estimate the deformation of soil-steel structures under construction. Although the examples concern railway structures, the methodology proposed in the paper is suitable also for road bridges.

  7. A segment of rbcL gene as a potential tool for forensic discrimination of Cannabis sativa seized at Rio de Janeiro, Brazil.

    Science.gov (United States)

    Mello, I C T; Ribeiro, A S D; Dias, V H G; Silva, R; Sabino, B D; Garrido, R G; Seldin, L; de Moura Neto, Rodrigo Soares

    2016-03-01

    Cannabis sativa, known by the common name marijuana, is the psychoactive drug most widely distributed in the world. Identification of Cannabis cultivars may be useful for association to illegal crops, which may reveal trafficking routes and related criminal groups. This study provides evidence for the performance of a segment of the rbcL gene, through genetic signature, as a tool for identification for C. sativa samples apprehended by the Rio de Janeiro Police, Brazil. The PCR amplified and further sequenced the fragment of approximately 561 bp of 24 samples of C. sativa rbcL gene and showed the same nucleotide sequences, suggesting a possible genetic similarity or identical varieties. Comparing with other Cannabaceae family sequences, we have found 99% of similarity between the Rio de Janeiro sequence and three other C. sativa rbcL genes. These findings suggest that the fragment utilized at this study is efficient in identifying C. sativa samples, therefore, useful in genetic discrimination of samples seized in forensic cases.

  8. Single motor–variable stiffness actuator using bistable switching mechanisms for independent motion and stiffness control

    NARCIS (Netherlands)

    Groothuis, Stefan; Carloni, Raffaella; Stramigioli, Stefano

    This paper presents a proof of concept of a variable stiffness actuator (VSA) that uses only one (high power) input motor. In general, VSAs use two (high power) motors to be able to control both the output position and the output stiffness, which possibly results in a heavy, and bulky system. In

  9. Red blood cell populations and membrane levels of peroxiredoxin 2 as candidate biomarkers to reveal blood doping.

    Science.gov (United States)

    Marrocco, Cristina; Pallotta, Valeria; D'alessandro, Angelo; Alves, Gilda; Zolla, Lello

    2012-05-01

    Blood doping represents one main trend in doping strategies. Blood doping refers to the practice of boosting the number of red blood cells (RBCs) in the bloodstream in order to enhance athletic performance, by means of blood transfusions, administration of erythropoiesis-stimulating substances, blood substitutes, natural or artificial altitude facilities, and innovative gene therapies. While detection of recombinant EPO and homologous transfusion is already feasible through electrophoretic, mass spectrometry or flow cytometry-based approaches, no method is currently available to tackle doping strategies relying on autologous transfusions. We exploited an in vitro model of autologous transfusion through a 1:10 dilution of concentrated RBCs after 30 days of storage upon appropriate dilution in freshly withdrawn RBCs from the same donor. Western blot towards membrane Prdx2 and Percoll density gradients were exploited to assess their suitability as biomarkers of transfusion. Membrane Prdx2 was visible in day 30 samples albeit not in day 0, while it was still visible in the 1:10 dilution of day 30 in day 0 RBCs. Cell gradients also highlighted changes in the profile of the RBC subpopulations upon dilution of stored RBCs in the fresh ones. From this preliminary in vitro investigation it emerges that Prdx2 and RBC populations might be further tested as candidate biomarkers of blood doping through autologous transfusion, though it is yet to be assessed whether the kinetics in vivo of Prdx2 exposure in the membrane of transfused RBCs will endow a sufficient time-window to allow reliable anti-doping testing.

  10. A sequence in subdomain 2 of DBL1α of Plasmodium falciparum erythrocyte membrane protein 1 induces strain transcending antibodies.

    Directory of Open Access Journals (Sweden)

    Karin Blomqvist

    Full Text Available Immunity to severe malaria is the first level of immunity acquired to Plasmodium falciparum. Antibodies to the variant antigen PfEMP1 (P. falciparum erythrocyte membrane protein 1 present at the surface of the parasitized red blood cell (pRBC confer protection by blocking microvascular sequestration. Here we have generated antibodies to peptide sequences of subdomain 2 of PfEMP1-DBL1α previously identified to be associated with severe or mild malaria. A set of sera generated to the amino acid sequence KLQTLTLHQVREYWWALNRKEVWKA, containing the motif ALNRKE, stained the live pRBC. 50% of parasites tested (7/14 were positive both in flow cytometry and immunofluorescence assays with live pRBCs including both laboratory strains and in vitro adapted clinical isolates. Antibodies that reacted selectively with the sequence REYWWALNRKEVWKA in a 15-mer peptide array of DBL1α-domains were also found to react with the pRBC surface. By utilizing a peptide array to map the binding properties of the elicited anti-DBL1α antibodies, the amino acids WxxNRx were found essential for antibody binding. Complementary experiments using 135 degenerate RDSM peptide sequences obtained from 93 Ugandan patient-isolates showed that antibody binding occurred when the amino acids WxLNRKE/D were present in the peptide. The data suggests that the ALNRKE sequence motif, associated with severe malaria, induces strain-transcending antibodies that react with the pRBC surface.

  11. Big bang nucleosynthesis with a stiff fluid

    International Nuclear Information System (INIS)

    Dutta, Sourish; Scherrer, Robert J.

    2010-01-01

    Models that lead to a cosmological stiff fluid component, with a density ρ S that scales as a -6 , where a is the scale factor, have been proposed recently in a variety of contexts. We calculate numerically the effect of such a stiff fluid on the primordial element abundances. Because the stiff fluid energy density decreases with the scale factor more rapidly than radiation, it produces a relatively larger change in the primordial helium-4 abundance than in the other element abundances, relative to the changes produced by an additional radiation component. We show that the helium-4 abundance varies linearly with the density of the stiff fluid at a fixed fiducial temperature. Taking ρ S10 and ρ R10 to be the stiff fluid energy density and the standard density in relativistic particles, respectively, at T=10 MeV, we find that the change in the primordial helium abundance is well-fit by ΔY p =0.00024(ρ S10 /ρ R10 ). The changes in the helium-4 abundance produced by additional radiation or by a stiff fluid are identical when these two components have equal density at a 'pivot temperature', T * , where we find T * =0.55 MeV. Current estimates of the primordial 4 He abundance give the constraint on a stiff fluid energy density of ρ S10 /ρ R10 <30.

  12. Direct measurement of the intrinsic ankle stiffness during standing.

    Science.gov (United States)

    Vlutters, M; Boonstra, T A; Schouten, A C; van der Kooij, H

    2015-05-01

    Ankle stiffness contributes to standing balance, counteracting the destabilizing effect of gravity. The ankle stiffness together with the compliance between the foot and the support surface make up the ankle-foot stiffness, which is relevant to quiet standing. The contribution of the intrinsic ankle-foot stiffness to balance, and the ankle-foot stiffness amplitude dependency remain a topic of debate in the literature. We therefore developed an experimental protocol to directly measure the bilateral intrinsic ankle-foot stiffness during standing balance, and determine its amplitude dependency. By applying fast (40 ms) ramp-and-hold support surface rotations (0.005-0.08 rad) during standing, reflexive contributions could be excluded, and the amplitude dependency of the intrinsic ankle-foot stiffness was investigated. Results showed that reflexive activity could not have biased the torque used for estimating the intrinsic stiffness. Furthermore, subjects required less recovery action to restore balance after bilateral rotations in opposite directions compared to rotations in the same direction. The intrinsic ankle-foot stiffness appears insufficient to ensure balance, ranging from 0.93±0.09 to 0.44±0.06 (normalized to critical stiffness 'mgh'). This implies that changes in muscle activation are required to maintain balance. The non-linear stiffness decrease with increasing rotation amplitude supports the previous published research. With the proposed method reflexive effects can be ruled out from the measured torque without any model assumptions, allowing direct estimation of intrinsic stiffness during standing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Flexibility contra Stiffness: The Phragmoplast as a Physical Barrier for Beads But Not for Vesicles[OA

    Science.gov (United States)

    Esseling-Ozdoba, Agnieszka; Kik, Richard A.; van Lammeren, André A.M.; Kleijn, J. Mieke; Emons, Anne Mie C.

    2010-01-01

    In plant cells, Golgi vesicles are transported to the division plane to fuse with each other, forming the cell plate, the initial membrane-bordered cell wall separating daughter cells. Vesicles, but not organelles, move through the phragmoplast, which consists of two opposing cylinders of microtubules and actin filaments, interlaced with endoplasmic reticulum membrane. To study physical aspects of this transport/inhibition process, we microinjected fluorescent synthetic 1,2-dioleoyl-sn-glycero-3-phospho-rac-1-glycerol (DOPG) vesicles and polystyrene beads into Tradescantia virginiana stamen hair cells. The phragmoplast was nonselective for DOPG vesicles of a size up to 150 nm in diameter but was a physical barrier for polystyrene beads having a diameter of 20 and 40 nm and also when beads were coated with the same DOPG membrane. We conclude that stiffness is a parameter for vesicle transit through the phragmoplast and discuss that cytoskeleton configurations can physically block such transit. PMID:19939943

  14. Observed variations of monopile foundation stiffness

    DEFF Research Database (Denmark)

    Kallehave, Dan; Thilsted, C.L.; Diaz, Alberto Troya

    2015-01-01

    full-scale measurements obtained from one offshore wind turbine structure located within Horns Reef II offshore wind farm. Data are presented for a 2.5 years period and covers normal operating conditions and one larger storm event. A reduction of the pile-soil stiffness was observed during the storm...... events, followed by a complete regain to a pre-storm level when the storm subsided. In additional, no long term variations of the pile-soil stiffness was observed. The wind turbine is located in dense to very dense sand deposits.......The soil-structure stiffness of monopile foundations for offshore wind turbines has a high impact on the fatigue loading during normal operating conditions. Thus, a robust design must consider the evolution of pile-soil stiffness over the lifetime of the wind farm. This paper present and discuss...

  15. Stiff Hands

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Stiff Hands Email to a friend * required fields ...

  16. A Stewart isolator with high-static-low-dynamic stiffness struts based on negative stiffness magnetic springs

    Science.gov (United States)

    Zheng, Yisheng; Li, Qingpin; Yan, Bo; Luo, Yajun; Zhang, Xinong

    2018-05-01

    In order to improve the isolation performance of passive Stewart platforms, the negative stiffness magnetic spring (NSMS) is employed to construct high static low dynamic stiffness (HSLDS) struts. With the NSMS, the resonance frequencies of the platform can be reduced effectively without deteriorating its load bearing capacity. The model of the Stewart isolation platform with HSLDS struts is presented and the stiffness characteristic of its struts is studied firstly. Then the nonlinear dynamic model of the platform including both geometry nonlinearity and stiffness nonlinearity is established; and its simplified dynamic model is derived under the condition of small vibration. The effect of nonlinearity on the isolation performance is also evaluated. Finally, a prototype is built and the isolation performance is tested. Both simulated and experimental results demonstrate that, by using the NSMS, the resonance frequencies of the Stewart isolator are reduced and the isolation performance in all six directions is improved: the isolation frequency band is increased and extended to a lower-frequency level.

  17. Dynamics of membrane nanotubes coated with I-BAR

    Science.gov (United States)

    Barooji, Younes F.; Rørvig-Lund, Andreas; Semsey, Szabolcs; Reihani, S. Nader S.; Bendix, Poul M.

    2016-07-01

    Membrane deformation is a necessary step in a number of cellular processes such as filopodia and invadopodia formation and has been shown to involve membrane shaping proteins containing membrane binding domains from the IRSp53-MIM protein family. In reconstituted membranes the membrane shaping domains can efficiently deform negatively charged membranes into tubules without any other proteins present. Here, we show that the IM domain (also called I-BAR domain) from the protein ABBA, forms semi-flexible nanotubes protruding into Giant Unilamellar lipid Vesicles (GUVs). By simultaneous quantification of tube intensity and tubular shape we find both the diameter and stiffness of the nanotubes. I-BAR decorated tubes were quantified to have a diameter of ~50 nm and exhibit no stiffening relative to protein free tubes of the same diameter. At high protein density the tubes are immobile whereas at lower density the tubes diffuse freely on the surface of the GUV. Bleaching experiments of the fluorescently tagged I-BAR confirmed that the mobility of the tubes correlates with the mobility of the I-BAR on the GUV membrane. Finally, at low density of I-BAR the protein upconcentrates within tubes protruding into the GUVs. This implies that I-BAR exhibits strong preference for negatively curved membranes.

  18. Numerical analysis of a red blood cell flowing through a thin micropore.

    Science.gov (United States)

    Omori, Toshihiro; Hosaka, Haruki; Imai, Yohsuke; Yamaguchi, Takami; Ishikawa, Takuji

    2014-01-01

    Red blood cell (RBC) deformability plays a key role in microcirculation, especially in vessels that have diameters even smaller than the nominal cell size. In this study, we numerically investigate the dynamics of an RBC in a thin micropore. The RBC is modeled as a capsule with a thin hyperelastic membrane. In a numerical simulation, we employ a boundary element method for fluid mechanics and a finite element method for membrane mechanics. The resulting RBC deformation towards the flow direction is suppressed considerably by increased cytoplasm viscosity, whereas the gap between the cell membrane and solid wall becomes smaller with higher cytoplasm viscosity. We also measure the transit time of the RBC and find that nondimensional transit time increases nonlinearly with respect to the viscosity ratio, whereas it is invariant to the capillary number. In conclusion, cytoplasmic viscosity plays a key role in the dynamics of an RBC in a thin pore. The results of this study will be useful for designing a microfluidic device to measure cytoplasmic viscosity.

  19. A novel energy-efficient rotational variable stiffness actuator

    NARCIS (Netherlands)

    Rao, S.; Carloni, Raffaella; Stramigioli, Stefano

    This paper presents the working principle, the design and realization of a novel rotational variable stiffness actuator, whose stiffness can be varied independently of its output angular position. This actuator is energy-efficient, meaning that the stiffness of the actuator can be varied by keeping

  20. Large strain variable stiffness composites for shear deformations with applications to morphing aircraft skins

    Science.gov (United States)

    McKnight, G. P.; Henry, C. P.

    2008-03-01

    Morphing or reconfigurable structures potentially allow for previously unattainable vehicle performance by permitting several optimized structures to be achieved using a single platform. The key to enabling this technology in applications such as aircraft wings, nozzles, and control surfaces, are new engineered materials which can achieve the necessary deformations but limit losses in parasitic actuation mass and structural efficiency (stiffness/weight). These materials should exhibit precise control of deformation properties and provide high stiffness when exercised through large deformations. In this work, we build upon previous efforts in segmented reinforcement variable stiffness composites employing shape memory polymers to create prototype hybrid composite materials that combine the benefits of cellular materials with those of discontinuous reinforcement composites. These composites help overcome two key challenges for shearing wing skins: the resistance to out of plane buckling from actuation induced shear deformation, and resistance to membrane deflections resulting from distributed aerodynamic pressure loading. We designed, fabricated, and tested composite materials intended for shear deformation and address out of plane deflections in variable area wing skins. Our designs are based on the kinematic engineering of reinforcement platelets such that desired microstructural kinematics is achieved through prescribed boundary conditions. We achieve this kinematic control by etching sheets of metallic reinforcement into regular patterns of platelets and connecting ligaments. This kinematic engineering allows optimization of materials properties for a known deformation pathway. We use mechanical analysis and full field photogrammetry to relate local scale kinematics and strains to global deformations for both axial tension loading and shear loading with a pinned-diamond type fixture. The Poisson ratio of the kinematically engineered composite is ~3x higher than

  1. Stiffness and the automatic selection of ODE codes

    International Nuclear Information System (INIS)

    Shampine, L.F.

    1984-01-01

    The author describes the basic ideas behind the most popular methods for the numerical solution of ordinary differential equations (ODEs). He takes up the qualitative behavior of solutions of ODEs and its relation ot the propagation of numerical error. Codes for ODEs are intended either for stiff problems or for non-stiff problems. The difference is explained. Users of codes do not have the information needed to recognize stiffness. A code, DEASY, which automatically recognizes stiffness and selects a suitable method is described

  2. Tattoo-Like Strain Gauges Based on Silicon Nano-Membranes

    Science.gov (United States)

    Lu, Nanshu

    2012-02-01

    This talk reports the in vivo measurement of tissue deformation through adhesive-free, conformable lamination of a tattoo-like elastic strain gauge consisted of piezoresistive silicon nano-membranes strategically integrated with tissue-like elastomeric substrates. The mechanical deformation in soft tissues cannot yet be directly quantified due to the lack of enabling tools. While stiff strain gauges for structural health monitoring have long existed, biological tissues are soft, curvilinear and highly deformable in contrast to civil or aerospace structures. An ultra-thin, ultra-soft, tattoo-like strain gauge that can conform to the convoluted surface of human body and stay attached during locomotion will be able to directly quantify tissue deformation without affecting the mechanical behavior of the tissue. While single crystalline silicon is known to have the highest gauge factor and best elastic response, it is intrinsically stiff and brittle. To achieve strain gauges with high compliance, high stretchability and reasonable sensitivity, single crystalline silicon nano-membranes will be transfer-printed onto polymeric support through carefully engineered stamps. The thickness and length of the Si strip will be chosen according to theoretical and numerical mechanics analysis which takes into account for the tradeoff between stretchability and sensitivity.

  3. Multi-fingered haptic palpation utilizing granular jamming stiffness feedback actuators

    International Nuclear Information System (INIS)

    Li, Min; Sareh, Sina; Seneviratne, Lakmal D; Wurdemann, Helge A; Althoefer, Kaspar; Ranzani, Tommaso; Dasgupta, Prokar

    2014-01-01

    This paper describes a multi-fingered haptic palpation method using stiffness feedback actuators for simulating tissue palpation procedures in traditional and in robot-assisted minimally invasive surgery. Soft tissue stiffness is simulated by changing the stiffness property of the actuator during palpation. For the first time, granular jamming and pneumatic air actuation are combined to realize stiffness modulation. The stiffness feedback actuator is validated by stiffness measurements in indentation tests and through stiffness discrimination based on a user study. According to the indentation test results, the introduction of a pneumatic chamber to granular jamming can amplify the stiffness variation range and reduce hysteresis of the actuator. The advantage of multi-fingered palpation using the proposed actuators is proven by the comparison of the results of the stiffness discrimination performance using two-fingered (sensitivity: 82.2%, specificity: 88.9%, positive predicative value: 80.0%, accuracy: 85.4%, time: 4.84 s) and single-fingered (sensitivity: 76.4%, specificity: 85.7%, positive predicative value: 75.3%, accuracy: 81.8%, time: 7.48 s) stiffness feedback. (paper)

  4. RBC deformability and amino acid concentrations after hypo-osmotic challenge may reflect chronic cell hydration status in healthy young men

    Science.gov (United States)

    Stookey, Jodi D; Klein, Alexis; Hamer, Janice; Chi, Christine; Higa, Annie; Ng, Vivian; Arieff, Allen; Kuypers, Frans A; Larkin, Sandra; Perrier, Erica; Lang, Florian

    2013-01-01

    Biomarkers of chronic cell hydration status are needed to determine whether chronic hyperosmotic stress increases chronic disease risk in population-representative samples. In vitro, cells adapt to chronic hyperosmotic stress by upregulating protein breakdown to counter the osmotic gradient with higher intracellular amino acid concentrations. If cells are subsequently exposed to hypo-osmotic conditions, the adaptation results in excess cell swelling and/or efflux of free amino acids. This study explored whether increased red blood cell (RBC) swelling and/or plasma or urine amino acid concentrations after hypo-osmotic challenge might be informative about relative chronic hyperosmotic stress in free-living men. Five healthy men (20–25 years) with baseline total water intake below 2 L/day participated in an 8-week clinical study: four 2-week periods in a U-shaped A-B-C-A design. Intake of drinking water was increased by +0.8 ± 0.3 L/day in period 2, and +1.5 ± 0.3 L/day in period 3, and returned to baseline intake (0.4 ± 0.2 L/day) in period 4. Each week, fasting blood and urine were collected after a 750 mL bolus of drinking water, following overnight water restriction. The periods of higher water intake were associated with significant decreases in RBC deformability (index of cell swelling), plasma histidine, urine arginine, and urine glutamic acid. After 4 weeks of higher water intake, four out of five participants had ½ maximal RBC deformability below 400 mmol/kg; plasma histidine below 100 μmol/L; and/or undetectable urine arginine and urine glutamic acid concentrations. Work is warranted to pursue RBC deformability and amino acid concentrations after hypo-osmotic challenge as possible biomarkers of chronic cell hydration. PMID:24303184

  5. A novel variable stiffness mechanism for dielectric elastomer actuators

    Science.gov (United States)

    Li, Wen-Bo; Zhang, Wen-Ming; Zou, Hong-Xiang; Peng, Zhi-Ke; Meng, Guang

    2017-08-01

    In this paper, a novel variable stiffness mechanism is proposed for the design of a variable stiffness dielectric elastomer actuator (VSDEA) which combines a flexible strip with a DEA in a dielectric elastomer minimum energy structure. The DEA induces an analog tuning of the transverse curvature of the strip, thus conveniently providing a voltage-controllable flexural rigidity. The VSDEA tends to be a fully flexible and compact structure with the advantages of simplicity and fast response. Both experimental and theoretical investigations are carried out to reveal the variable stiffness performances of the VSDEA. The effect of the clamped location on the bending stiffness of the VSDEA is analyzed, and then effects of the lengths, the loading points and the applied voltages on the bending stiffness are experimentally investigated. An analytical model is developed to verify the availability of this variable stiffness mechanism, and the theoretical results demonstrate that the bending stiffness of the VSDEA decreases as the applied voltage increases, which agree well with the experimental data. Moreover, the experimental results show that the maximum change of the relative stiffness can reach about 88.80%. It can be useful for the design and optimization of active variable stiffness structures and DEAs for soft robots, vibration control, and morphing applications.

  6. Hybrid continuum-coarse-grained modeling of erythrocytes

    Science.gov (United States)

    Lyu, Jinming; Chen, Paul G.; Boedec, Gwenn; Leonetti, Marc; Jaeger, Marc

    2018-06-01

    The red blood cell (RBC) membrane is a composite structure, consisting of a phospholipid bilayer and an underlying membrane-associated cytoskeleton. Both continuum and particle-based coarse-grained RBC models make use of a set of vertices connected by edges to represent the RBC membrane, which can be seen as a triangular surface mesh for the former and a spring network for the latter. Here, we present a modeling approach combining an existing continuum vesicle model with a coarse-grained model for the cytoskeleton. Compared to other two-component approaches, our method relies on only one mesh, representing the cytoskeleton, whose velocity in the tangential direction of the membrane may be different from that of the lipid bilayer. The finitely extensible nonlinear elastic (FENE) spring force law in combination with a repulsive force defined as a power function (POW), called FENE-POW, is used to describe the elastic properties of the RBC membrane. The mechanical interaction between the lipid bilayer and the cytoskeleton is explicitly computed and incorporated into the vesicle model. Our model includes the fundamental mechanical properties of the RBC membrane, namely fluidity and bending rigidity of the lipid bilayer, and shear elasticity of the cytoskeleton while maintaining surface-area and volume conservation constraint. We present three simulation examples to demonstrate the effectiveness of this hybrid continuum-coarse-grained model for the study of RBCs in fluid flows.

  7. Neuronal Differentiation Modulated by Polymeric Membrane Properties.

    Science.gov (United States)

    Morelli, Sabrina; Piscioneri, Antonella; Drioli, Enrico; De Bartolo, Loredana

    2017-01-01

    In this study, different collagen-blend membranes were successfully constructed by blending collagen with chitosan (CHT) or poly(lactic-co-glycolic acid) (PLGA) to enhance their properties and thus create new biofunctional materials with great potential use for neuronal tissue engineering and regeneration. Collagen blending strongly affected membrane properties in the following ways: (i) it improved the surface hydrophilicity of both pure CHT and PLGA membranes, (ii) it reduced the stiffness of CHT membranes, but (iii) it did not modify the good mechanical properties of PLGA membranes. Then, we investigated the effect of the different collagen concentrations on the neuronal behavior of the membranes developed. Morphological observations, immunocytochemistry, and morphometric measures demonstrated that the membranes developed, especially CHT/Col30, PLGA, and PLGA/Col1, provided suitable microenvironments for neuronal growth owing to their enhanced properties. The most consistent neuronal differentiation was obtained in neurons cultured on PLGA-based membranes, where a well-developed neuronal network was achieved due to their improved mechanical properties. Our findings suggest that tensile strength and elongation at break are key material parameters that have potential influence on both axonal elongation and neuronal structure and organization, which are of fundamental importance for the maintenance of efficient neuronal growth. Hence, our study has provided new insights regarding the effects of membrane mechanical properties on neuronal behavior, and thus it may help to design and improve novel instructive biomaterials for neuronal tissue engineering. © 2017 S. Karger AG, Basel.

  8. Lower Body Stiffness Modulation Strategies in Well Trained Female Athletes.

    Science.gov (United States)

    Millett, Emma L; Moresi, Mark P; Watsford, Mark L; Taylor, Paul G; Greene, David A

    2016-10-01

    Millett, EL, Moresi, MP, Watsford, ML, Taylor, PG, and Greene, DA. Lower body stiffness modulation strategies in well trained female athletes. J Strength Cond Res 30(10): 2845-2856, 2016-Lower extremity stiffness quantifies the relationship between the amount of leg compression and the external load to which the limb are subjected. This study aimed to assess differences in leg and joint stiffness and the subsequent kinematic and kinetic control mechanisms between athletes from various training backgrounds. Forty-seven female participants (20 nationally identified netballers, 13 high level endurance athletes and 14 age and gender matched controls) completed a maximal unilateral countermovement jump, drop jump and horizontal jump to assess stiffness. Leg stiffness, joint stiffness and associated mechanical parameters were assessed with a 10 camera motion analysis system and force plate. No significant differences were evident for leg stiffness measures between athletic groups for any of the tasks (p = 0.321-0.849). However, differences in joint stiffness and its contribution to leg stiffness, jump performance outcome measures and stiffness control mechanisms were evident between all groups. Practitioners should consider the appropriateness of the task utilised in leg stiffness screening. Inclusion of mechanistic and/or more sports specific tasks may be more appropriate for athletic groups.

  9. Stiffness Evolution in Frozen Sands Subjected to Stress Changes

    KAUST Repository

    Dai, Sheng; Santamarina, Carlos

    2017-01-01

    Sampling affects all soils, including frozen soils and hydrate-bearing sediments. The authors monitor the stiffness evolution of frozen sands subjected to various temperature and stress conditions using an oedometer cell instrumented with P-wave transducers. Experimental results show the stress-dependent stiffness of freshly remolded sands, the dominant stiffening effect of ice, creep after unloading, and the associated exponential decrease in stiffness with time. The characteristic time for stiffness loss during creep is of the order of tens of minutes; therefore it is inevitable that frozen soils experience sampling disturbances attributable to unloading. Slow unloading minimizes stiffness loss; conversely, fast unloading causes a pronounced reduction in stiffness probably attributable to the brittle failure of ice or ice-mineral bonding.

  10. Stiffness Evolution in Frozen Sands Subjected to Stress Changes

    KAUST Repository

    Dai, Sheng

    2017-04-21

    Sampling affects all soils, including frozen soils and hydrate-bearing sediments. The authors monitor the stiffness evolution of frozen sands subjected to various temperature and stress conditions using an oedometer cell instrumented with P-wave transducers. Experimental results show the stress-dependent stiffness of freshly remolded sands, the dominant stiffening effect of ice, creep after unloading, and the associated exponential decrease in stiffness with time. The characteristic time for stiffness loss during creep is of the order of tens of minutes; therefore it is inevitable that frozen soils experience sampling disturbances attributable to unloading. Slow unloading minimizes stiffness loss; conversely, fast unloading causes a pronounced reduction in stiffness probably attributable to the brittle failure of ice or ice-mineral bonding.

  11. Experimental Challenges to Stiffness as a Transport Paradigm

    Science.gov (United States)

    Luce, T. C.

    2017-10-01

    Transport in plasmas is treated experimentally as a relationship between gradients and fluxes in analogy to the random-walk problem. Gyrokinetic models often predict strong increases in local flux for small increases in local gradient when above a threshold, holding all other parameters fixed. This has been named `stiffness'. The radial scalelength is then expected to vary little with source strength as a result of high stiffness. To probe the role of ExB shearing on stiffness in the DIII-D tokamak, two neutral beam injection power scans in H-mode plasmas were specially crafted-one with constant, low torque and one with increasing torque. The ion heat, electron heat, and ion toroidal momentum transport do not show expected signatures of stiffness, while the ion particle transport does. The ion heat transport shows the clearest discrepancy; the normalized heat flux drops with increasing inverse ion temperature scalelength. ExB shearing affects the transport magnitude, but not the scalelength dependence. Linear gyrofluid (TGLF) and nonlinear gyrokinetic (GYRO) predictions show stiff ion heat transport around the experimental profiles. The ion temperature gradient required to match the ion heat flux with increasing auxiliary power is not correctly described by TGLF, even when parameters are varied within the experimental uncertainties. TGLF also underpredicts transport at smaller radii, but overpredicts transport at larger radii. Independent of the theory/experiment comparison, it is not clear that the theoretical definition of stiffness yields any prediction about parameter scans such as the power scans here, because the quantities that must be held fixed to quantify stiffness are varied. A survey of recent literature indicated that profile resilience is routinely attributed to stiffness, but simple model calculations show profile resilience does not imply stiffness. Taken together, these observations challenge the use of local stiffness as a paradigm for explaining

  12. Long-chain PUFA in Granulocytes, Mononuclear Cells, and RBC in Patients With Cystic Fibrosis: Relation to Liver Disease

    DEFF Research Database (Denmark)

    Jorgensen, Marianne H.; Ott, Peter; Michaelsen, Kim F.

    2012-01-01

    -related liver disease were matched with 20 CF patients without. Blood samples were analysed for liver biochemistry and haematology. Granulocytes, mononuclear cells, and RBC were separated by density gradient centrifugation, and fatty acid composition was measured by gas chromatography. Hepatic ultrasound...

  13. Stiffness Evaluation of High Temperature Superconductor Bearing Stiffness for 10 kWh Superconductor Flywheel Energy Storage System

    International Nuclear Information System (INIS)

    Park, B. J.; Jung, S. Y.; Lee, J. P.; Park, B. C.; Kim, C. H.; Han, S. C.; Du, S. G.; Han, Y. H.; Sung, T. H.

    2009-01-01

    A superconductor flywheel energy storage(SFES) system is mainly act an electro-mechanical battery which transfers mechanical energy into electrical form and vice versa. SFES system consists of a pair of non-contacting High Temperature Superconductor (HTS) bearings with a very low frictional loss. But it is essential to design an efficient HTS bearing considering with rotor dynamic properties through correct calculation of stiffness in order to support a huge composite flywheel rotor with high energy storage density. Static properties of HTS bearings provide data to solve problems which may occur easily in a running system. Since stiffness to counter vibration is the main parameter in designing an HTS bearing system, we investigate HTS bearing magnetic force through static properties between the Permanent Magnet(PM) and HTS. We measured axial / radial stiffness and found bearing stiffness can be easily changed by activated vibration direction between PM and HTS bulk. These results are used to determine the optimal design for a 10 kWh SFES.

  14. Stiffness and damping in mechanical design

    National Research Council Canada - National Science Library

    Rivin, Eugene I

    1999-01-01

    ... important conceptual issues are stiffness of mechanical structures and their components and damping in mechanical systems sensitive to and/or generating vibrations. Stiffness and strength are the most important criteria for many mechanical designs. However, although there are hundreds of books on various aspects of strength, and strength issues ar...

  15. The Effect of Shoe Insole Stiffness on Leg Stiffness during Stance Phase of Running in Two Different Speeds ‎among Active Men

    Directory of Open Access Journals (Sweden)

    Zeinab Tazike-Lemeski

    2016-08-01

    Full Text Available Introduction: The effect of shoe insoles with different characteristics and in different running speeds on lower-limb stiffness is still ‎controversial. The aim of this study was to investigate the effect of two types of insoles (soft and semi-rigid in two ‎different running speeds on leg stiffness during stance phase of running among active men.‎ Materials and Methods: ‎15 male students without any background of lower extremity injury were selected. Subjects were asked to run with ‎two controlled velocities of 3.0 ± 0.2 and 5.0 ± 0.1 m/s in control and insole conditions (soft and semi-rigid on a ‎force plate, placed on the middle of 15-meter runway. The cinematics and cinetics of motion were measured and ‎calculated using 5 video cameras and one force plate. The leg stiffness was achieved via dividing the vertical ‎ground reaction force by leg compression. Two-factor repeated measures ANOVA was used to test the hypothesis at ‎the significance level of P £ 0.050.‎ Results: There was a significant difference between the two types of insoles on leg stiffness. In fact, semi-rigid insole significantly increased leg stiffness (P < 0.001. However, this discrepancy was not related to the running speed (P = 0.999. In addition, there was no significant difference between the two different speeds on leg stiffness (P = 0.632. Conclusion: It seems that the increase in shoe insole stiffness may increase the leg stiffness. Furthermore, the effect of insole ‎stiffness is not related to the running speed, and leg stiffness will remains constant in low to medium running speeds.‎

  16. Force-dependent breaching of the basement membrane.

    Science.gov (United States)

    Chang, Tammy T; Thakar, Dhruv; Weaver, Valerie M

    2017-01-01

    Clinically, non-invasive carcinomas are confined to the epithelial side of the basement membrane and are classified as benign, whereas invasive cancers invade through the basement membrane and thereby acquire the potential to metastasize. Recent findings suggest that, in addition to protease-mediated degradation and chemotaxis-stimulated migration, basement membrane invasion by malignant cells is significantly influenced by the stiffness of the associated interstitial extracellular matrix and the contractility of the tumor cells that is dictated in part by their oncogenic genotype. In this review, we highlight recent findings that illustrate unifying molecular mechanisms whereby these physical cues contribute to tissue fibrosis and malignancy in three epithelial organs: breast, pancreas, and liver. We also discuss the clinical implications of these findings and the biological properties and clinical challenges linked to the unique biology of each of these organs. Copyright © 2017 International Society of Matrix Biology. Published by Elsevier B.V. All rights reserved.

  17. Optical Assay of Erythrocyte Function in Banked Blood

    Science.gov (United States)

    Bhaduri, Basanta; Kandel, Mikhail; Brugnara, Carlo; Tangella, Krishna; Popescu, Gabriel

    2014-09-01

    Stored red blood cells undergo numerous biochemical, structural, and functional changes, commonly referred to as storage lesion. How much these changes impede the ability of erythrocytes to perform their function and, as result, impact clinical outcomes in transfusion patients is unknown. In this study we investigate the effect of the storage on the erythrocyte membrane deformability and morphology. Using optical interferometry we imaged red blood cell (RBC) topography with nanometer sensitivity. Our time-lapse imaging quantifies membrane fluctuations at the nanometer scale, which in turn report on cell stiffness. This property directly impacts the cell's ability to transport oxygen in microvasculature. Interestingly, we found that cells which apparently maintain their normal shape (discocyte) throughout the storage period, stiffen progressively with storage time. By contrast, static parameters, such as mean cell hemoglobin content and morphology do not change during the same period. We propose that our method can be used as an effective assay for monitoring erythrocyte functionality during storage time.

  18. The stable stiffness triangle - drained sand during deformation cycles

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    2017-01-01

    Cyclic, drained sand stiffness was observed using the Danish triaxial appa- ratus. New, deformation dependant soil property (the stable stiffness triangle) was detected. Using the the stable stiffness triangle, secant stiffness of drained sand was plausible to predict (and control) even during ir...... findings can find application in off-shore, seismic and other engi- neering practice, or inspire new branches of research and modelling wherever dynamic, cyclic or transient loaded sand is encountered....

  19. Pipe elbow stiffness coefficients including shear and bend flexibility factors for use in direct stiffness codes

    International Nuclear Information System (INIS)

    Perry, R.F.

    1977-01-01

    Historically, developments of computer codes used for piping analysis were based upon the flexibility method of structural analysis. Because of the specialized techniques employed in this method, the codes handled systems composed of only piping elements. Over the past ten years, the direct stiffness method has gained great popularity because of its systematic solution procedure regardless of the type of structural elements composing the system. A great advantage is realized with a direct stiffness code that combines piping elements along with other structural elements such as beams, plates, and shells, in a single model. One common problem, however, has been the lack of an accurate pipe elbow element that would adequately represent the effects of transverse shear and bend flexibility factors. The purpose of the present paper is to present a systematic derivation of the required 12x12 stiffness matrix and load vectors for a three dimensional pipe elbow element which includes the effects of transverse shear and pipe bend flexibility according to the ASME Boiler and Pressure Vessel Code, Section III. The results are presented analytically and as FORTRAN subroutines to be directly incorporated into existing direct stiffness codes. (Auth.)

  20. Direct measurement of the intrinsic ankle stiffness during standing

    NARCIS (Netherlands)

    Vlutters, Mark; Vlutters, M.; Boonstra, Tjitske; Schouten, Alfred Christiaan; van der Kooij, Herman

    2015-01-01

    Ankle stiffness contributes to standing balance, counteracting the destabilizing effect of gravity. The ankle stiffness together with the compliance between the foot and the support surface make up the ankle-foot stiffness, which is relevant to quiet standing. The contribution of the intrinsic

  1. Operator-Based Preconditioning of Stiff Hyperbolic Systems

    International Nuclear Information System (INIS)

    Reynolds, Daniel R.; Samtaney, Ravi; Woodward, Carol S.

    2009-01-01

    We introduce an operator-based scheme for preconditioning stiff components encountered in implicit methods for hyperbolic systems of partial differential equations posed on regular grids. The method is based on a directional splitting of the implicit operator, followed by a characteristic decomposition of the resulting directional parts. This approach allows for solution to any number of characteristic components, from the entire system to only the fastest, stiffness-inducing waves. We apply the preconditioning method to stiff hyperbolic systems arising in magnetohydro- dynamics and gas dynamics. We then present numerical results showing that this preconditioning scheme works well on problems where the underlying stiffness results from the interaction of fast transient waves with slowly-evolving dynamics, scales well to large problem sizes and numbers of processors, and allows for additional customization based on the specific problems under study

  2. Biomechanical constraints on the feedforward regulation of endpoint stiffness.

    Science.gov (United States)

    Hu, Xiao; Murray, Wendy M; Perreault, Eric J

    2012-10-01

    Although many daily tasks tend to destabilize arm posture, it is still possible to have stable interactions with the environment by regulating the multijoint mechanics of the arm in a task-appropriate manner. For postural tasks, this regulation involves the appropriate control of endpoint stiffness, which represents the stiffness of the arm at the hand. Although experimental studies have been used to evaluate endpoint stiffness control, including the orientation of maximal stiffness, the underlying neural strategies remain unknown. Specifically, the relative importance of feedforward and feedback mechanisms has yet to be determined due to the difficulty separately identifying the contributions of these mechanisms in human experiments. This study used a previously validated three-dimensional musculoskeletal model of the arm to quantify the degree to which the orientation of maximal endpoint stiffness could be changed using only steady-state muscle activations, used to represent feedforward motor commands. Our hypothesis was that the feedforward control of endpoint stiffness orientation would be significantly constrained by the biomechanical properties of the musculoskeletal system. Our results supported this hypothesis, demonstrating substantial biomechanical constraints on the ability to regulate endpoint stiffness throughout the workspace. The ability to regulate stiffness orientation was further constrained by additional task requirements, such as the need to support the arm against gravity or exert forces on the environment. Together, these results bound the degree to which slowly varying feedforward motor commands can be used to regulate the orientation of maximum arm stiffness and provide a context for better understanding conditions in which feedback control may be needed.

  3. Formation of carrageenan-CaCO{sub 3} bioactive membranes

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Lucas F.B.; Maniglia, Bianca C.; Pereira, Lourivaldo S.; Tapia-Blácido, Delia R.; Ramos, Ana P., E-mail: anapr@ffclrp.usp.br

    2016-01-01

    The high biocompatibility and resorbability of polymeric membranes have encouraged their use to manufacture medical devices. Here, we report on the preparation of membranes consisting of carrageenan, a naturally occurring sulfated polysaccharide that forms helical structures in the presence of calcium ions. We incorporated CaCO{sub 3} particles into the membranes to enhance their bioactivity and mechanical properties. Infrared spectroscopy and X-ray diffraction data confirmed CaCO{sub 3} incorporation into the polymeric matrix. We tested the bioactivity of the samples by immersing them in a solution that mimics the ionic composition and pH of the human body fluid. The hybrid membranes generated hydroxyapatite, as attested by X-ray diffraction data. Scanning electron and atomic force microscopies aided investigation of membrane topography before and after CaCO{sub 3} deposition. The wettability and surface free energy, evaluated by contact angle measures, increased in the presence of CaCO{sub 3} particles. These parameters are important for membrane implantation in the body. Moreover, membrane stiffness was up to 110% higher in the presence of the inorganic particles, as revealed by Young's modulus. - Highlights: • Hybrid kappa and iota carrageenan-CaCO{sub 3} membranes were formed. • The hybrid membrane's origin hydroxyapatite after exposure to simulated body fluid • The carrageenan's specificity to bind Ca{sup 2+} ions tailors the surface properties.

  4. Tissue Characterization of Lemna gibba rbcS Promoter%浮萍rbcS启动子组织特性研究

    Institute of Scientific and Technical Information of China (English)

    黄凤珍; 李倩; 王友如

    2015-01-01

    A new rbcS (ribulose-1,5-bisphosphate carboxylase small subunit) promoter with the size of 1 438 bp (named SSU5C promoter) was cloned from Lemna gibba. SSU5C promoter was fused with the GUS reporter gene to construct a plant binary vector (pSSU5C-IGUS), and introduced into duckweed by agrogacterium-mediated trans-formation. The transgenic plantlets were generated. This study was focused on the tissue characterization of SSU5C promoter. GUS staining showed that SSU5C promoter drove GUS to express in the green tissue in leaf, stem and petiole of T1 tobacco, whereas no GUS activity was observed in root. In reproductive organs, the GUS activity was observed in corolla lobes, anther and stigma, no GUS activity was observed in other parts. It was obvious that rbcS promoter can not only express in the green tissue, but also can express in reproductive organs. The results lay a good doundation for the application of SSU5C in plant genetic engineering.%SSU5C启动子(全长1438 bp)是从浮萍基因组中新克隆的一个rb c S (ribulose-1,5-bisphosphate carbo-xylase small subunit)启动子。本研究将 SSU5C 启动子与GUS基因融合,成功构建植物双元表达载p SSU5C-IGUS,并利用农杆菌介导法转化烟草,获得转基因植株,探究SSU5C启动子在烟草中的组织表达特点。GUS检测结果表明:在T1烟草的营养器官中,SSU5C启动子主要驱动GUS基因在烟草叶片和叶柄、茎等绿色组织中表达,而在根部不表达;在生殖器官中,GUS基因主要在花冠裂片以及花药和柱头中表达。本研究首次发现浮萍rb c S启动子不仅在绿色组织中表达,而且在生殖器官中的花冠裂片以及花药和柱头中表达,这一发现可为SSU5C启动子在植物基因工程中的应用奠定基础。

  5. The study of stiffness modulus values for AC-WC pavement

    Science.gov (United States)

    Lubis, AS; Muis, Z. A.; Iskandar, T. D.

    2018-02-01

    One of the parameters of the asphalt mixture in order for the strength and durability to be achieved as required is the stress-and-strain showing the stiffness of a material. Stiffness modulus is a very necessary factor that will affect the performance of asphalt pavements. If the stiffness modulus value decreases there will be a cause of aging asphalt pavement crack easily when receiving a heavy load. The high stiffness modulus asphalt concrete causes more stiff and resistant to bending. The stiffness modulus value of an asphalt mixture material can be obtained from the theoretical (indirect methods) and laboratory test results (direct methods). For the indirect methods used Brown & Brunton method, and Shell Bitumen method; while for the direct methods used the UMATTA tool. This study aims to determine stiffness modulus values for AC-WC pavement. The tests were conducted in laboratory that used 3 methods, i.e. Brown & Brunton Method, Shell Bitumen Method and Marshall Test as a substitute tool for the UMATTA tool. Hotmix asphalt made from type AC-WC with pen 60/70 using a mixture of optimum bitumen content was 5.84% with a standard temperature variation was 60°C and several variations of temperature that were 30, 40, 50, 70 and 80°C. The stiffness modulus value results obtained from Brown & Brunton Method, Shell Bitumen Method and Marshall Test which were 1374,93 Mpa, 235,45 Mpa dan 254,96 Mpa. The stiffness modulus value decreases with increasing temperature of the concrete asphalt. The stiffness modulus value from the Bitumen Shell method and the Marshall Test has a relatively similar value.The stiffness modulus value from the Brown & Brunton method is greater than the Bitumen Shell method and the Marshall Test, but can not measure the stiffness modulus value at temperature above 80°C.

  6. Simvastatin Ameliorates Matrix Stiffness-Mediated Endothelial Monolayer Disruption.

    Directory of Open Access Journals (Sweden)

    Marsha C Lampi

    Full Text Available Arterial stiffening accompanies both aging and atherosclerosis, and age-related stiffening of the arterial intima increases RhoA activity and cell contractility contributing to increased endothelium permeability. Notably, statins are 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA reductase inhibitors whose pleiotropic effects include disrupting small GTPase activity; therefore, we hypothesized the statin simvastatin could be used to attenuate RhoA activity and inhibit the deleterious effects of increased age-related matrix stiffness on endothelial barrier function. Using polyacrylamide gels with stiffnesses of 2.5, 5, and 10 kPa to mimic the physiological stiffness of young and aged arteries, endothelial cells were grown to confluence and treated with simvastatin. Our data indicate that RhoA and phosphorylated myosin light chain activity increase with matrix stiffness but are attenuated when treated with the statin. Increases in cell contractility, cell-cell junction size, and indirect measurements of intercellular tension that increase with matrix stiffness, and are correlated with matrix stiffness-dependent increases in monolayer permeability, also decrease with statin treatment. Furthermore, we report that simvastatin increases activated Rac1 levels that contribute to endothelial barrier enhancing cytoskeletal reorganization. Simvastatin, which is prescribed clinically due to its ability to lower cholesterol, alters the endothelial cell response to increased matrix stiffness to restore endothelial monolayer barrier function, and therefore, presents a possible therapeutic intervention to prevent atherogenesis initiated by age-related arterial stiffening.

  7. Washout of water-soluble vitamins and of homocysteine during haemodialysis: effect of high-flux and low-flux dialyser membranes.

    Science.gov (United States)

    Heinz, Judith; Domröse, Ute; Westphal, Sabine; Luley, Claus; Neumann, Klaus H; Dierkes, Jutta

    2008-10-01

    Vitamin deficiencies are common in patients with end-stage renal disease (ESRD) owing to dietary restrictions, drug-nutrient interactions, changes in metabolism, and vitamin losses during dialysis. The present study investigated the levels of serum and red blood cell (RBC) folate, plasma pyridoxal-5'-phosphate (PLP), serum cobalamin, blood thiamine, blood riboflavin, and plasma homocysteine (tHcy) before and after haemodialysis treatment. Vitamin and tHcy blood concentrations were measured in 30 patients with ESRD before and after dialysis session either with low-flux (n = 15) or high-flux (n = 15) dialysers. After the dialysis procedure, significantly lower concentrations of serum folate (37%), plasma PLP (35%), blood thiamine (6%) and blood riboflavin (7%) were observed. No significant changes were found for serum cobalamin or for RBC folate. There were no differences in the washout of water-soluble vitamins between treatments with low-flux and high-flux membranes. Furthermore, a 41% lower concentration in tHcy was observed. The percentage decrease in tHcy was significantly greater in the patients treated with high-flux dialysers (48% vs 37%; P vitamins measured (r =-0.867, P water-soluble vitamins after dialysis, independently of the dialyser membrane. The monitoring of the vitamin status is essential in patients treated with high-flux dialysers as well as in patients treated with low-flux dialysers.

  8. Modulation of erythrocyte membrane mechanical stability by 2,3-diphosphoglycerate in the neonatal poikilocytosis/elliptocytosis syndrome.

    Science.gov (United States)

    Mentzer, W C; Iarocci, T A; Mohandas, N; Lane, P A; Smith, B; Lazerson, J; Hays, T

    1987-01-01

    To explain the transient anemia and poikilocytosis seen during infancy in hereditary elliptocytosis (HE), we resealed erythrocyte (RBC) ghosts from affected children or their elliptocytic parents with 2,3-diphosphoglycerate (DPG) (0-8 mM), a compound that dissociates membrane skeletons, then measured ghost mechanical stability in the ektacytometer. Without added 2,3-DPG, ghost mechanical stability was subnormal in infantile poikilocytosis (IP) and HE but was even more abnormal in hereditary pyropoikilocytosis (HPP). Addition of 2,3-DPG (2.55 mM) to IP or HE ghosts, decreased their stability to that of HPP ghosts (without 2,3-DPG). Nonphysiological 2,3-DPG levels (6-8 mM) were required to elicit a similar effect in normal ghosts. The data suggest that free 2,3-DPG, present in neonatal RBC as a consequence of diminished binding to HbF, may render HE susceptible to in vivo fragmentation. The developmental switch from fetal to adult hemoglobin, by diminishing available free 2,3-DPG, may explain the abatement of poikilocytosis and hemolytic anemia that accompanies maturation. Images PMID:3818955

  9. Analysis of Dynamic Stiffness of Bridge Cap-Pile System

    Directory of Open Access Journals (Sweden)

    Jinhui Chu

    2018-01-01

    Full Text Available In order to investigate the applicability of dynamic stiffness for bridge cap-pile system, a laboratory test was performed. A numerical model was also built for this type of system. The impact load was applied on the cap top and the dynamic stiffness was analysed. Then, the effect of the effective friction area between pile and soil was also considered. Finally, the dynamic stiffness relationship between the single pile and the cap-pile system was also compared. The results show that the dynamic stiffness is a sensitive index and can well reflect the static characteristics of the pile at the elastic stage. There is a significant positive correlation between the vertical dynamic stiffness index and bearing capacity of the cap-pile system in the similar formation environment. For the cap-pile system with four piles, the dynamic stiffness is about four times as large as the single pile between 10 and 20 Hz.

  10. Stiff quantum polymers

    OpenAIRE

    Kleinert, H.

    2009-01-01

    At ultralow temperatures, polymers exhibit quantum behavior, which is calculated here for the second and fourth moments of the end-to-end distribution in the large-stiffness regime. The result should be measurable for polymers in wide optical traps.

  11. Arterial Stiffness in Children: Pediatric Measurement and Considerations

    Science.gov (United States)

    Savant, Jonathan D.; Furth, Susan L.; Meyers, Kevin E.C.

    2014-01-01

    Background Arterial stiffness is a natural consequence of aging, accelerated in certain chronic conditions, and predictive of cardiovascular events in adults. Emerging research suggests the importance of arterial stiffness in pediatric populations. Methods There are different indices of arterial stiffness. The present manuscript focuses on carotid-femoral pulse wave velocity and pulse wave analysis, although other methodologies are discussed. Also reviewed are specific measurement considerations for pediatric populations and the literature describing arterial stiffness in children with certain chronic conditions (primary hypertension, obesity, diabetes, chronic kidney disease, hypercholesterolemia, genetic syndromes involving vasculopathy, and solid organ transplant recipients). Conclusions The measurement of arterial stiffness in children is feasible and, under controlled conditions, can give accurate information about the underlying state of the arteries. This potentially adds valuable information about the functionality of the cardiovascular system in children with a variety of chronic diseases well beyond that of the brachial artery blood pressure. PMID:26587447

  12. Enhancement of the blood compatibility of dialyzer membranes by the physical adsorption of human thrombomodulin (ART-123).

    Science.gov (United States)

    Omichi, Masaaki; Matsusaki, Michiya; Kato, Shinya; Maruyama, Ikuro; Akashi, Mitsuru

    2010-11-01

    ART-123 is a recombinant soluble human thrombomodulin (hTM) with excellent anticoagulant activity. We focused on improving the blood compatibility of the polysulfone-polyvinylpyrrolidone dialyzer surface by the physical adsorption of ART-123 onto the surface. The blood compatibility of the dialyzer with the hTM adsorbed membrane was evaluated by measuring the differential pressure between the arterial and the venous pressures and by blood parameters during blood circulation. The hTM adsorbed dialyzer membrane inhibited blood clot formation without heparin administration due to the anticoagulant activity of hTM for over 4 h. The physically adsorbed hTM was stable during blood circulation, and it did not affect activated clotting time, which is significant drawback of heparin administration, and blood cell counts of RBC, WBC, or platelets. The physical adsorption of hTM onto the dialyzer membrane will be a simple and safe method to prevent blood coagulation during dialysis instead of heparin administration. © 2010 Wiley Periodicals, Inc.

  13. Ball Bearing Stiffnesses- A New Approach Offering Analytical Expressions

    Science.gov (United States)

    Guay, Pascal; Frikha, Ahmed

    2015-09-01

    Space mechanisms use preloaded ball bearings in order to withstand the severe vibrations during launch.The launch strength requires the calculation of the bearing stiffness, but this calculation is complex. Nowadays, there is no analytical expression that gives the stiffness of a bearing. Stiffness is computed using an iterative algorithm such as Newton-Raphson, to solve the nonlinear system of equations.This paper aims at offering a simplified analytical approach, based on the assumption that the contact angle is constant. This approach gives analytical formulas of the stiffness of preloaded ball bearing.

  14. Plant fibre composites - porosity and stiffness

    DEFF Research Database (Denmark)

    Madsen, Bo; Thygesen, Anders; Lilholt, Hans

    2009-01-01

    Plant fibre composites contain typically a relatively large amount of porosity which influences their performance. A model, based on a modified rule of mixtures, is presented to include the influence of porosity on the composite stiffness. The model integrates the volumetric composition...... of the composites with their mechanical properties. The fibre weight fraction is used as an independent parameter to calculate the complete volumetric composition. A maximum obtainable stiffness of the composites is calculated at a certain transition fibre weight fraction, which is characterised by a best possible...... combination of high fibre volume fraction and low porosity. The model is validated with experimental data from the literature on several types of composites. A stiffness diagram is presented to demonstrate that the calculations can be used for tailoring and design of composites with a given profile...

  15. Molecular Cues Guiding Matrix Stiffness in Liver Fibrosis

    Directory of Open Access Journals (Sweden)

    Takaoki Saneyasu

    2016-01-01

    Full Text Available Tissue and matrix stiffness affect cell properties during morphogenesis, cell growth, differentiation, and migration and are altered in the tissue remodeling following injury and the pathological progression. However, detailed molecular mechanisms underlying alterations of stiffness in vivo are still poorly understood. Recent engineering technologies have developed powerful techniques to characterize the mechanical properties of cell and matrix at nanoscale levels. Extracellular matrix (ECM influences mechanical tension and activation of pathogenic signaling during the development of chronic fibrotic diseases. In this short review, we will focus on the present knowledge of the mechanisms of how ECM stiffness is regulated during the development of liver fibrosis and the molecules involved in ECM stiffness as a potential therapeutic target for liver fibrosis.

  16. Low frequency acoustic properties of bilayer membrane acoustic metamaterial with magnetic oscillator

    Directory of Open Access Journals (Sweden)

    Nansha Gao

    2017-07-01

    Full Text Available A bilayer membrane acoustic metamaterial was proposed to overcome the influence of the mass law on traditional acoustic materials and obtain a lightweight thin-layer structure that can effectively isolate low frequency noise. The finite element analysis (FEA results agree well with the experimental results. It is proved that the sound transmission losses (STLs of the proposed structures are higher than those of same surface density acoustic materials. The introduction of the magnetic mass block is different from the traditional design method, in which only a passive mass block is fixed on the membrane. The magnetic force will cause tension in the membrane, increase membrane prestress, and improve overall structural stiffness. The effects of the geometry size on the STLs are discussed in detail. The kind of method presented in this paper can provide a new means for engineering noise control. Keywords: Bilayer membrane acoustic metamaterial, Low frequency sound insulation, Sound transmission loss, Magnet oscillator

  17. Membranes: A Variety of Energy Landscapes for Many Transfer Opportunities.

    Science.gov (United States)

    Bacchin, Patrice

    2018-02-22

    A membrane can be represented by an energy landscape that solutes or colloids must cross. A model accounting for the momentum and the mass balances in the membrane energy landscape establishes a new way of writing for the Darcy law. The counter-pressure in the Darcy law is no longer written as the result of an osmotic pressure difference but rather as a function of colloid-membrane interactions. The ability of the model to describe the physics of the filtration is discussed in detail. This model is solved in a simplified energy landscape to derive analytical relationships that describe the selectivity and the counter-pressure from ab initio operating conditions. The model shows that the stiffness of the energy landscape has an impact on the process efficiency: a gradual increase in interactions (such as with hourglass pore shape) can reduce the separation energetic cost. It allows the introduction of a new paradigm to increase membrane efficiency: the accumulation that is inherent to the separation must be distributed across the membrane. Asymmetric interactions thus lead to direction-dependent transfer properties and the membrane exhibits diode behavior. These new transfer opportunities are discussed.

  18. Reflexiones sobre la estrategia de rehabilitación basada en la comunidad (RBC: la experiencia de un programa de RBC en Bolivia Reflections on community-based rehabilitation strategy (CBR: the experience of a CBR program in Bolivia

    Directory of Open Access Journals (Sweden)

    Urko Díaz-Aristizabal

    2012-01-01

    Full Text Available La Rehabilitación Basada en la Comunidad (RBC es una estrategia de desarrollo comunitario avalada por la Organización Mundial de la Salud (OMS, la Organización Internacional del Trabajo (OIT y la Organización de las Naciones Unidas para la Educación, la Ciencia y la Cultura (UNESCO, que persigue la rehabilitación, la igualdad de oportunidades y la integración social de las Personas con Discapacidad (PD en sus entornos. Con este objetivo promueve la colaboración entre las PD, sus familias y los diferentes actores de la comunidad involucrados, así como el liderazgo comunitario y la participación de las PD mediante el impulso de la colaboración multisectorial. Este artículo expone los antecedentes históricos y las características fundamentales de la estrategia de RBC a partir de un programa llevado a cabo por una fundación del departamento de Cochabamba (Bolivia, para después incidir en algunos aspectos referentes al contexto sociocultural, que especialmente en situaciones de interculturalidad, pueden determinar que un programa de RBC tenga éxito o esté abocado al fracaso.Community-Based Rehabilitation (CBR is a strategy for community development endorsed by the World Health Organization (WHO, the International Labor Office (ILO and the United Nations Educational, Scientific and Cultural Organization (UNESCO. It is designed to promote rehabilitation, equal opportunity and social inclusion of Disabled Persons (DP in their home communities by fostering cooperation among disabled individuals, their families, and other concerned social actors, it encourages community leadership and full social participation by DP through multi-sector cooperation. This article explores the historical antecedents and basic features of CBR strategy through an analysis of a directed culture change initiative developed by a foundation in the Cochabamba administrative region of Bolivia. Especially in intercultural environments, certain aspects of the socio

  19. DPD simulation on the dynamics of a healthy and infected red blood cell in flow through a constricted channel

    Science.gov (United States)

    Hoque, Sazid Zamal; Anand, D. Vijay; Patnaik, B. S. V.

    2017-11-01

    The state of the red blood cell (either healthy or infected RBC) will influence its deformation dynamics. Since the pathological condition related to RBC, primarily originates from a single cell infection, therefore, it is important to relate the deformation dynamics to the mechanical properties (such as, bending rigidity and membrane elasticity). In the present study, numerical simulation of a healthy and malaria infected RBC in a constricted channel is analyzed. The flow simulations are carried out using finite sized dissipative particle dynamics (FDPD) method in conjunction with a discrete model that represents the membrane of the RBC. The numerical equivalent of optical tweezers test is validated against the experimental studies. Two different types of constrictions, viz., a converging-diverging type tapered channel and a stenosed microchannel are considered for the simulation. The effect of degree of constriction and the flow rate effect on the RBC is investigated. It was observed that, as the flow rate decreases, the infected RBC completely blocks the micro vessel. The transit time for infected cell drastically increases compared to healthy RBC. Our simulations indicate that, there is a critical flow rate below which infected RBC cannot pass through the micro capillary.

  20. Is chronic obstructive pulmonary disease associated with increased arterial stiffness?

    DEFF Research Database (Denmark)

    Janner, Julie H; McAllister, David A; Godtfredsen, Nina S

    2012-01-01

    We hypothesize that airflow limitation is associated with increasing arterial stiffness and that having COPD increases a non-invasive measure of arterial stiffness - the aortic augmentation index (AIx) - independently of other CVD risk factors.......We hypothesize that airflow limitation is associated with increasing arterial stiffness and that having COPD increases a non-invasive measure of arterial stiffness - the aortic augmentation index (AIx) - independently of other CVD risk factors....

  1. A Rapid Aeroelasticity Optimization Method Based on the Stiffness characteristics

    OpenAIRE

    Yuan, Zhe; Huo, Shihui; Ren, Jianting

    2018-01-01

    A rapid aeroelasticity optimization method based on the stiffness characteristics was proposed in the present study. Large time expense in static aeroelasticity analysis based on traditional time domain aeroelasticity method is solved. Elastic axis location and torsional stiffness are discussed firstly. Both torsional stiffness and the distance between stiffness center and aerodynamic center have a direct impact on divergent velocity. The divergent velocity can be adjusted by changing the cor...

  2. Damper modules with adapted stiffness ratio

    Energy Technology Data Exchange (ETDEWEB)

    Sonnenburg, R.; Stretz, A. [ZF Sachs AG, Entwicklungszentrum, Schweinfurt (Germany)

    2011-07-15

    A mechanism for the excitation of piston rod vibrations in automotive damper modules is discussed by a simple model. An improved nonlinear model based on elasticity effects leads to good simulation results. It is shown theoretically and experimentally that the adaptation of the stiffness of the piston rod bushing to the ''stiffness'' of the damper force characteristic can eliminate the piston rod oscillations completely. (orig.)

  3. Rotational and peak torque stiffness of rugby shoes.

    Science.gov (United States)

    Ballal, Moez S; Usuelli, Federico Giuseppe; Montrasio, Umberto Alfieri; Molloy, Andy; La Barbera, Luigi; Villa, Tomaso; Banfi, Giuseppe

    2014-09-01

    Sports people always strive to avoid injury. Sports shoe designs in many sports have been shown to affect traction and injury rates. The aim of this study is to demonstrate the differing stiffness and torque in rugby boots that are designed for the same effect. Five different types of rugby shoes commonly worn by scrum forwards were laboratory tested for rotational stiffness and peak torque on a natural playing surface generating force patterns that would be consistent with a rugby scrum. The overall internal rotation peak torque was 57.75±6.26 Nm while that of external rotation was 56.55±4.36 Nm. The Peak internal and external rotational stiffness were 0.696±0.1 and 0.708±0.06 Nm/deg respectively. Our results, when compared to rotational stiffness and peak torques of football shoes published in the literature, show that shoes worn by rugby players exert higher rotational and peak torque stiffness compared to football shoes when tested on the same natural surfaces. There was significant difference between the tested rugby shoes brands. In our opinion, to maximize potential performance and lower the potential of non-contact injury, care should be taken in choosing boots with stiffness appropriate to the players main playing role. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Pharmacological targeting of membrane rigidity: implications on cancer cell migration and invasion

    International Nuclear Information System (INIS)

    Braig, Simone; Stoiber, Katharina; Zahler, Stefan; Vollmar, Angelika M

    2015-01-01

    The invasive potential of cancer cells strongly depends on cellular stiffness, a physical quantity that is not only regulated by the mechanical impact of the cytoskeleton but also influenced by the membrane rigidity. To analyze the specific role of membrane rigidity in cancer progression, we treated cancer cells with the Acetyl-CoA carboxylase inhibitor Soraphen A and revealed an alteration of the phospholipidome via mass spectrometry. Migration, invasion, and cell death assays were employed to relate this alteration to functional consequences, and a decrease of migration and invasion without significant impact on cell death has been recorded. Fourier fluctuation analysis of giant plasma membrane vesicles showed that Soraphen A increases membrane rigidity of carcinoma cell membranes. Mechanical measurements of the creep deformation response of whole intact cells were performed using the optical stretcher. The increase in membrane rigidity was observed in one cell line without changing the creep deformation response indicating no restructuring of the cytoskeleton. These data indicate that the increase of membrane rigidity alone is sufficient to inhibit invasiveness of cancer cells, thus disclosing the eminent role of membrane rigidity in migratory processes. (paper)

  5. Static stiffness modeling of a novel hybrid redundant robot machine

    International Nuclear Information System (INIS)

    Li Ming; Wu Huapeng; Handroos, Heikki

    2011-01-01

    This paper presents a modeling method to study the stiffness of a hybrid serial-parallel robot IWR (Intersector Welding Robot) for the assembly of ITER vacuum vessel. The stiffness matrix of the basic element in the robot is evaluated using matrix structural analysis (MSA); the stiffness of the parallel mechanism is investigated by taking account of the deformations of both hydraulic limbs and joints; the stiffness of the whole integrated robot is evaluated by employing the virtual joint method and the principle of virtual work. The obtained stiffness model of the hybrid robot is analytical and the deformation results of the robot workspace under certain external load are presented.

  6. Stiffness requirement of flexible skin for variable trailing-edge camber wing

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The method for analyzing the deformation of flexible skin under the air loads was developed based on the panel method and finite element method.The deformation of flexible skin under air pressures and effects of the local deformation on the aerodynamic characteristics were discussed.Numerical results show that the flexible skin on the upper surface of trailing-edge will bubble under the air loads and the bubble has a powerful effect on the aerodynamic pressure near the surface of local deforma-tion.Then the stiffness requirements for flexible skin of variable trailing-edge were given by using the Jacobs rule,i.e.,the maximum displacement of skin is not greater than 0.1% of wing chord.Results show that the in-plane stiffness can be reduced by increasing the ratio of bending stiffness to in-plane stiffness.Although the deformation of flexible skin increases with the in-plane stiffness decreasing,it depends on the bending stiffness.When the bending stiffness exceeds critical value,the deformation of flexible skin only depends on the bending stiffness and has nothing to do with the in-plane stiffness.The conclusions can be used for the structural design of flexible skin.

  7. Subspace methods for identification of human ankle joint stiffness.

    Science.gov (United States)

    Zhao, Y; Westwick, D T; Kearney, R E

    2011-11-01

    Joint stiffness, the dynamic relationship between the angular position of a joint and the torque acting about it, describes the dynamic, mechanical behavior of a joint during posture and movement. Joint stiffness arises from both intrinsic and reflex mechanisms, but the torques due to these mechanisms cannot be measured separately experimentally, since they appear and change together. Therefore, the direct estimation of the intrinsic and reflex stiffnesses is difficult. In this paper, we present a new, two-step procedure to estimate the intrinsic and reflex components of ankle stiffness. In the first step, a discrete-time, subspace-based method is used to estimate a state-space model for overall stiffness from the measured overall torque and then predict the intrinsic and reflex torques. In the second step, continuous-time models for the intrinsic and reflex stiffnesses are estimated from the predicted intrinsic and reflex torques. Simulations and experimental results demonstrate that the algorithm estimates the intrinsic and reflex stiffnesses accurately. The new subspace-based algorithm has three advantages over previous algorithms: 1) It does not require iteration, and therefore, will always converge to an optimal solution; 2) it provides better estimates for data with high noise or short sample lengths; and 3) it provides much more accurate results for data acquired under the closed-loop conditions, that prevail when subjects interact with compliant loads.

  8. Pulling a polymer with anisotropic stiffness near a sticky wall

    International Nuclear Information System (INIS)

    Tabbara, R; Owczarek, A L

    2012-01-01

    We solve exactly a two-dimensional partially directed walk model of a semi-flexible polymer that has one end tethered to a sticky wall, while a pulling force away from the adsorbing surface acts on the free end of the walk. This model generalizes a number of previously considered adsorption models by incorporating individual horizontal and vertical stiffness effects, in competition with a variable pulling angle. A solution to the corresponding generating function is found by means of the kernel method. While the phases and related phase transitions are similar in nature to those found previously the analysis of the model in terms of its physical variables highlights various novel structures in the shapes of the phase diagrams and related behaviour of the polymer. We review the results of previously considered sub-cases, augmenting these findings to include analysis with respect to the model’s physical variables—namely, temperature, pulling force, pulling angle away from the surface, stiffness strength and the ratio of vertical to horizontal stiffness potentials, with our subsequent analysis for the general model focusing on the effect that stiffness has on this pulling angle range. In analysing the model with stiffness we also pay special attention to the case where only vertical stiffness is included. The physical analysis of this case reveals behaviour more closely resembling that of an upward pulling force acting on a polymer than it does of a model where horizontal stiffness acts. The stiffness–temperature phase diagram exhibits re-entrance for low temperatures, previously only seen for three-dimensional or co-polymer models. For the most general model we delineate the shift in the physical behaviour as we change the ratio of vertical to horizontal stiffness between the horizontal-only and the vertical-only stiffness regimes. We find that a number of distinct physical characteristics will only be observed for a model where the vertical stiffness dominates

  9. Delimiting the species Neosiphonia yendoi (Rhodomelaceae, Rhodophyta) based on COI and rbcL genetic variation in Korea and Japan

    Science.gov (United States)

    Kim, Byeongseok; Yang, Mi Yeon; Kim, Myung Sook

    2016-09-01

    Although the marine red algal genus Neosiphonia is well characterized, many species of Neosiphonia are poorly understood. To correctly define the species delimitation of Neosiphonia yendoi using genetic variation, owing to the confusion over identification with " N. sphaerocarpa" from Korea, we investigated intensively the haplotype network of the mitochondrial COI and the plastid rbcL genes of specimens collected from Korea and Japan. The molecular analyses indicated that specimens collected in different sites of Korea and Japan belong to the same species, Neosiphonia yendoi and " Neosiphonia sphaerocarpa" from Korea, which is distinguished from N. sphaerocarpa from Florida and is allied with N. yendoi collected from the type locality, Muroran of Japan. A total of 29 COI and 13 rbcL haplotypes were found and the COI haplotype network shows evidence of a clear break between specimens from Jeju Island and all other locations of Korea, suggesting the possibility of cryptic diversity within N. yendoi.

  10. Transfusion Associated Hyperkalemia and Cardiac Arrest in an Infant after Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Do Wan Kim

    2015-05-01

    Full Text Available Cardiac arrest associated with hyperkalemia during red blood cell transfusion is a rare but fatal complication. Herein, we report a case of transfusion-associated cardiac arrest following the initiation of extracorporeal membrane oxygenation support in a 9-month old infant. Her serum potassium level was increased to 9.0 mEq/L, soon after the newly primed circuit with pre-stored red blood cell (RBC was started and followed by sudden cardiac arrest. Eventually, circulation was restored and the potassium level decreased to 5.1 mEq/L after 5 min. Extracorporeal membrane oxygenation (ECMO priming is a relatively massive transfusion into a pediatric patient. Thus, to prevent cardiac arrest during blood-primed ECMO in neonates and infants, freshly irradiated and washed RBCs should be used when priming the ECMO circuit, to minimize the potassium concentration. Also, physicians should be aware of all possible complications associated with transfusions during ECMO.

  11. Influence of stiffness on CHF for horizontal tubes under LPLF conditions

    Energy Technology Data Exchange (ETDEWEB)

    Baburajan, P.K. [Nuclear Safety Analysis Division, AERB, Niyamak Bhavan, 400094 (India); Bisht, Govind Singh [Department of Mechanical Engineering, IIT Bombay, 400076 (India); Gaikwad, Avinash J. [Nuclear Safety Analysis Division, AERB, Niyamak Bhavan, 400094 (India); Prabhu, S.V., E-mail: svprabhu@iitb.ac.in [Department of Mechanical Engineering, IIT Bombay, 400076 (India)

    2014-10-01

    Highlights: • Effect of stiffness on the CHF in horizontal tube under LPLF conditions is studied. • CHF increases with the increase in stiffness. • Correlation for the prediction of CHF as a function of stiffness is developed. • Correlation for mass flux at CHF in terms of stiffness and initial mass flux is given. • RELAP5 is capable of predicting the effect of stiffness on CHF. - Abstract: Studies reported in the past on critical heat flux (CHF) are mostly limited to vertical flow, large channel diameter, high pressure and high mass flux. Since horizontal flow is commonly encountered in boiler tubes, refrigerating equipments and nuclear reactor fuel channels (PHWR), there is a need to understand horizontal flow CHF, generate sufficient experimental database and to develop reliable predictive method. Few studies are reported on the effect of upstream flow restrictions on flow instabilities and CHF. The present work investigates the effect of upstream flow restriction on CHF in horizontal flow at near atmospheric pressure conditions. In the present study, stiffness is defined as the ratio of upstream flow restriction pressure drop to the test section pressure drop. The classification of a flow boiling system as soft or stiff on the basis of quantification of the stiffness is attempted. Experimental data shows an increase in the CHF with the increase in the stiffness for a given initial mass flux. A correlation for the prediction of CHF under various stiffness conditions is developed. A correlation is suggested to predict the mass flux at CHF as a function of stiffness and initial mass flux. Modeling and transient analysis of the stiffness effect on CHF is carried out using the thermal hydraulic system code RELAP5. The predicted phenomena are in agreement with the experimental observations.

  12. Fatigue crack paths under the influence of changes in stiffness

    Directory of Open Access Journals (Sweden)

    G. Kullmer

    2016-02-01

    Full Text Available An important topic of the Collaborative Research Centre TRR 30 of the Deutsche Forschungsgemeinschaft (DFG is the crack growth behaviour in graded materials. In addition, the growth of cracks in the neighbourhood of regions and through regions with different material properties belongs under this topic. Due to the different material properties, regions with differing stiffness compared to the base material may arise. Regions with differing stiffness also arise from ribs, grooves or boreholes. Since secure findings on the propagation behaviour of fatigue cracks are essential for the evaluation of the safety of components and structures, the growth of cracks near changes in stiffness has to be considered, too. Depending on the way a crack penetrates the zone of influence of such a change in stiffness and depending on whether this region is more compliant or stiffer than the surrounding area the crack may grow towards or away from this region. Both cases result in curved crack paths that cannot be explained only by the global loading situation. To evaluate the influence of regions with differing stiffness on the path of fatigue cracks the paths and the stress intensity factors of cracks growing near and through regions with differing stiffness are numerically determined with the program system ADAPCRACK3D. Therefore, arrangements of changes in stiffness modelled as material inclusions with stiffness properties different from the base material or modelled as ribs and grooves are systematically varied to develop basic conclusions about the crack growth behaviour near and through changes in stiffness.

  13. On prestress stiffness analysis of bolt-plate contact assemblies

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard; Pedersen, Pauli

    2008-01-01

    , but with finite element (FE) and contact analysis, it is possible to find the stiffness of the member. In the case of many connections and for practical applications, it is not suitable to make a full FE analysis. The purpose of the present paper is to find simplified expressions for the stiffness of the member......, including the case when the width of the member is limited. The calculation of the stiffness is based on the FE, including the solution to the contact problem, and we express the stiffness as a function of the elastic energy in the structure, whereby the definition of the displacements related...

  14. Low frequency noise reduction using stiff light composite panels

    Institute of Scientific and Technical Information of China (English)

    DENG Yongchang; LIN Weizheng

    2003-01-01

    The experiment presented in this paper is to investigate and analyze the noise reduction at low frequency using stiff light composite panels. Since these composite panels are made of lightweight and stiff materials, this actuation strategy will enable the creation of composite panels for duct noise control without using traditional heavy structural mass. The results suggest that the mass-spring resonance absorption in the case of a comparatively stiff thick panel with a thin flexible plate is more efficient with minimum weight, when subjected to low-frequency (<500 Hz). The efficiency of the panel absorber depends on the mass of the thin flexible plate and the stiffness of the panel.

  15. Elastin in large artery stiffness and hypertension

    Science.gov (United States)

    Wagenseil, Jessica E.; Mecham, Robert P.

    2012-01-01

    Large artery stiffness, as measured by pulse wave velocity (PWV), is correlated with high blood pressure and may be a causative factor in essential hypertension. The extracellular matrix components, specifically the mix of elastin and collagen in the vessel wall, determine the passive mechanical properties of the large arteries. Elastin is organized into elastic fibers in the wall during arterial development in a complex process that requires spatial and temporal coordination of numerous proteins. The elastic fibers last the lifetime of the organism, but are subject to proteolytic degradation and chemical alterations that change their mechanical properties. This review discusses how alterations in the amount, assembly, organization or chemical properties of the elastic fibers affect arterial stiffness and blood pressure. Strategies for encouraging or reversing alterations to the elastic fibers are addressed. Methods for determining the efficacy of these strategies, by measuring elastin amounts and arterial stiffness, are summarized. Therapies that have a direct effect on arterial stiffness through alterations to the elastic fibers in the wall may be an effective treatment for essential hypertension. PMID:22290157

  16. Advanced damper with negative structural stiffness elements

    International Nuclear Information System (INIS)

    Dong, Liang; Lakes, Roderic S

    2012-01-01

    Negative stiffness is understood as the occurrence of a force in the same direction as the imposed deformation. Structures and composites with negative stiffness elements enable a large amplification in damping. It is shown in this work, using an experimental approach, that when a flexible flat-ends column is aligned in a post-buckled condition, a negative structural stiffness and large hysteresis (i.e., high damping) can be achieved provided the ends of the column undergo tilting from flat to edge contact. Stable axial dampers with initial modulus equivalent to that of the parent material and with enhanced damping were designed and built using constrained negative stiffness effects entailed by post-buckled press-fit flat-ends columns. Effective damping of approximately 1 and an effective stiffness–damping product of approximately 1.3 GPa were achieved in such stable axial dampers consisting of PMMA columns. This is a considerable improvement for this figure of merit (i.e., the stiffness–damping product), which generally cannot exceed 0.6 GPa for currently used damping layers. (paper)

  17. Systematic profiling of spatiotemporal tissue and cellular stiffness in the developing brain.

    Science.gov (United States)

    Iwashita, Misato; Kataoka, Noriyuki; Toida, Kazunori; Kosodo, Yoichi

    2014-10-01

    Accumulating evidence implicates the significance of the physical properties of the niche in influencing the behavior, growth and differentiation of stem cells. Among the physical properties, extracellular stiffness has been shown to have direct effects on fate determination in several cell types in vitro. However, little evidence exists concerning whether shifts in stiffness occur in vivo during tissue development. To address this question, we present a systematic strategy to evaluate the shift in stiffness in a developing tissue using the mouse embryonic cerebral cortex as an experimental model. We combined atomic force microscopy measurements of tissue and cellular stiffness with immunostaining of specific markers of neural differentiation to correlate the value of stiffness with the characteristic features of tissues and cells in the developing brain. We found that the stiffness of the ventricular and subventricular zones increases gradually during development. Furthermore, a peak in tissue stiffness appeared in the intermediate zone at E16.5. The stiffness of the cortical plate showed an initial increase but decreased at E18.5, although the cellular stiffness of neurons monotonically increased in association with the maturation of the microtubule cytoskeleton. These results indicate that tissue stiffness cannot be solely determined by the stiffness of the cells that constitute the tissue. Taken together, our method profiles the stiffness of living tissue and cells with defined characteristics and can therefore be utilized to further understand the role of stiffness as a physical factor that determines cell fate during the formation of the cerebral cortex and other tissues. © 2014. Published by The Company of Biologists Ltd.

  18. Evaluating pulp stiffness from fibre bundles by ultrasound

    Science.gov (United States)

    Karppinen, Timo; Montonen, Risto; Määttänen, Marjo; Ekman, Axel; Myllys, Markko; Timonen, Jussi; Hæggström, Edward

    2012-06-01

    A non-destructive ultrasonic tester was developed to measure the stiffness of pulp bundles. The mechanical properties of pulp are important when estimating the behaviour of paper under stress. Currently available pulp tests are tedious and alter the fibres structurally and mechanically. The developed tester employs (933 ± 15) kHz tweezer-like ultrasonic transducers and time-of-flight measurement through (9.0 ± 2.5) mm long and (0.8 ± 0.1) mm thick fibre bundles kept at (19.1 ± 0.4) °C and (62 ± 1)% RH. We determined the stiffness of soft wood pulps produced by three kraft pulping modifications: standard kraft pulp, (5.2 ± 0.4) GPa, prehydrolysis kraft pulp, (4.3 ± 0.4) GPa, and alkali extracted prehydrolysis kraft pulp, (3.3 ± 0.4) GPa. Prehydrolysis and alkali extraction processes mainly lowered the hemicellulose content of the pulps, which essentially decreased the fibre-wall stiffness hence impairing the stiffness of the fibre networks. Our results indicate that the method allows ranking of pulps according to their stiffness determined from bundle-like samples taken at an early phase of the papermaking process.

  19. A new variable stiffness suspension system: passive case

    Directory of Open Access Journals (Sweden)

    O. M. Anubi

    2013-02-01

    Full Text Available This paper presents the design, analysis, and experimental validation of the passive case of a variable stiffness suspension system. The central concept is based on a recently designed variable stiffness mechanism. It consists of a horizontal control strut and a vertical strut. The main idea is to vary the load transfer ratio by moving the location of the point of attachment of the vertical strut to the car body. This movement is controlled passively using the horizontal strut. The system is analyzed using an L2-gain analysis based on the concept of energy dissipation. The analyses, simulation, and experimental results show that the variable stiffness suspension achieves better performance than the constant stiffness counterpart. The performance criteria used are; ride comfort, characterized by the car body acceleration, suspension deflection, and road holding, characterized by tire deflection.

  20. Association of Parental Hypertension With Arterial Stiffness in Nonhypertensive Offspring

    DEFF Research Database (Denmark)

    Andersson, Charlotte; Quiroz, Rene; Enserro, Danielle

    2016-01-01

    High arterial stiffness seems to be causally involved in the pathogenesis of hypertension. We tested the hypothesis that offspring of parents with hypertension may display higher arterial stiffness before clinically manifest hypertension, given that hypertension is a heritable condition. We compa......, in this community-based sample of young, nonhypertensive adults, we observed greater arterial stiffness in offspring of parents with hypertension. These observations are consistent with higher vascular stiffness at an early stage in the pathogenesis of hypertension.......High arterial stiffness seems to be causally involved in the pathogenesis of hypertension. We tested the hypothesis that offspring of parents with hypertension may display higher arterial stiffness before clinically manifest hypertension, given that hypertension is a heritable condition. We...... compared arterial tonometry measures in a sample of 1564 nonhypertensive Framingham Heart Study third-generation cohort participants (mean age: 38 years; 55% women) whose parents were enrolled in the Framingham Offspring Study. A total of 468, 715, and 381 participants had 0 (referent), 1, and 2 parents...

  1. VARIABLE STIFFNESS HAND PROSTHESIS: A SYSTEMATIC REVIEW

    Directory of Open Access Journals (Sweden)

    S. Cecilia Tapia-Siles

    2017-06-01

    Full Text Available Prosthetics is an important field in engineering due to the large number of amputees worldwide and the associated problems such as limited functionality of the state of the art. An important functionality of the human hand is its capability of adjusting the stiffness of the joints depending on the currently performed task. For the development of new technology it is important to understand the limitations of existing resources. As part of our efforts to develop a variable stiffness grasper for developing countries a systematic review was performed covering technology of body powered and myoelectric hand prosthesis. Focus of the review is readiness of prosthetic hands regarding their capability of controlling the stiffness of the end effector. Publications sourced through three different digital libraries were systematically reviewed on the basis of the PRISMA standard. We present a search strategy as well as the PRISMA assessment of the resulting records which covered 321 publications. The records were assessed and the results are presented for the ability of devices to control their joint stiffness. The review indicates that body powered prosthesis are preferred to myoelectric hands due to the reduced cost, the simplicity of use and because of their inherent ability to provide feedback to the user. Stiffness control was identified but has not been fully covered in the current state of the art. In addition we summarise the identified requirements on prosthetic hands as well as related information which can support the development of new prosthetics.

  2. Effect of long-term isometric training on core/torso stiffness.

    Science.gov (United States)

    Lee, Benjamin C Y; McGill, Stuart M

    2015-06-01

    Although core stiffness enhances athletic performance traits, controversy exists regarding the effectiveness of isometric vs. dynamic core training methods. This study aimed to determine whether long-term changes in stiffness can be trained, and if so, what is the most effective method. Twenty-four healthy male subjects (23 ± 3 years; 1.8 ± 0.06 m; 77.5 ± 10.8 kg) were recruited for passive and active stiffness measurements before and after a 6-week core training intervention. Twelve subjects (22 ± 2 years; 1.8 ± 0.08 m; 78.3 ± 12.3 kg) were considered naive to physical and core exercise. The other 12 subjects (24 ± 3 years; 1.8 ± 0.05 m; 76.8 ± 9.7 kg) were Muay Thai athletes (savvy). A repeated-measures design compared core training methods (isometric vs. dynamic, with a control group) and subject training experience (naive vs. savvy) before and after a 6-week training period. Passive stiffness was assessed on a "frictionless" bending apparatus and active stiffness assessed through a quick release mechanism. Passive stiffness increased after the isometric training protocol. Dynamic training produced a smaller effect, and as expected, there was no change in the control group. Active stiffness did not change in any group. Comparisons between subject and training groups did not reveal any interactions. Thus, an isometric training approach was superior in terms of enhancing core stiffness. This is important since increased core stiffness enhances load bearing ability, arrests painful vertebral micromovements, and enhances ballistic distal limb movement. This may explain the efficacy reported for back and knee injury reduction.

  3. [Metabolic syndrome and aortic stiffness].

    Science.gov (United States)

    Simková, A; Bulas, J; Murín, J; Kozlíková, K; Janiga, I

    2010-09-01

    The metabolic syndrome (MS) is a cluster of risk factors that move the patient into higher level of risk category of cardiovascular disease and the probability of type 2 diabetes mellitus manifestation. Definition of MS is s based on the presence of selected risk factors as: abdominal obesity (lager waist circumpherence), atherogenic dyslipidemia (low value of HDL-cholesterol and increased level of triglycerides), increased fasting blood glucose (or type 2 DM diagnosis), higher blood pressure or antihypertensive therapy. In 2009 there were created harmonizing criteria for MS definition; the condition for assignment of MS is the presence of any 3 criteria of 5 mentioned above. The underlying disorder of MS is an insulin resistance or prediabetes. The patients with MS more frequently have subclinical (preclinical) target organ disease (TOD) which is the early sings of atherosclerosis. Increased aortic stiffness is one of the preclinical diseases and is defined by pathologically increased carotidofemoral pulse wave velocity in aorta (PWV Ao). With the aim to assess the influence of MS on aortic stiffness we examined the group of women with arterial hypertension and MS and compare them with the group of women without MS. The aortic stiffness was examined by Arteriograph--Tensiomed, the equipment working on the oscillometric principle in detection of pulsations of brachial artery. This method determines the global aortic stiffness based on the analysis of the shape of pulse curve of brachial artery. From the cohort of 49 pts 31 had MS, the subgroups did not differ in age or blood pressure level. The mean number of risk factors per person in MS was 3.7 comparing with 1.7 in those without MS. In the MS group there was more frequently abdominal obesity present (87% vs 44%), increased fasting blood glucose (81% vs 22%) and low HDL-cholesterol level. The pulse wave velocity in aorta, PWV Ao, was significantly higher in patients with MS (mean value 10,19 m/s vs 8,96 m

  4. Sway‐dependent changes in standing ankle stiffness caused by muscle thixotropy

    Science.gov (United States)

    Sakanaka, Tania E.; Lakie, Martin

    2016-01-01

    Key points The passive stiffness of the calf muscles contributes to standing balance, although the properties of muscle tissue are highly labile.We investigated the effect of sway history upon intrinsic ankle stiffness and demonstrated reductions in stiffness of up to 43% during conditions of increased baseline sway.This sway dependence was most apparent when using low amplitude stiffness‐measuring perturbations, and the short‐range stiffness component was smaller during periods of high sway.These characteristics are consistent with the thixotropic properties of the calf muscles causing the observed changes in ankle stiffness.Periods of increased sway impair the passive stabilization of standing, demanding more active neural control of balance. Abstract Quiet standing is achieved through a combination of active and passive mechanisms, consisting of neural control and intrinsic mechanical stiffness of the ankle joint, respectively. The mechanical stiffness is partly determined by the calf muscles. However, the viscoelastic properties of muscle are highly labile, exhibiting a strong dependence on movement history. By measuring the effect of sway history upon ankle stiffness, the present study determines whether this lability has consequences for the passive stabilization of human standing. Ten subjects stood quietly on a rotating platform whose axis was collinear with the ankle joint. Ankle sway was increased by slowly tilting this platform in a random fashion, or decreased by fixing the body to a board. Ankle stiffness was measured by using the same platform to simultaneously apply small, brief perturbations (ankle stiffness by up to 43% compared to the body‐fixed condition. Normal quiet stance was associated with intermediate values. The effect was most apparent when using smaller perturbation amplitudes to measure stiffness (0.1 vs. 0.6 deg). Furthermore, torque responses exhibited a biphasic pattern, consisting of an initial steep rise followed by a

  5. Determination of Ankle and Metatarsophalangeal Stiffness During Walking and Jogging.

    Science.gov (United States)

    Mager, Fabian; Richards, Jim; Hennies, Malika; Dötzel, Eugen; Chohan, Ambreen; Mbuli, Alex; Capanni, Felix

    2018-05-29

    Forefoot stiffness has been shown to influence joint biomechanics. However, little or no data exists on metatarsophalangeal stiffness. Twenty-four healthy rearfoot strike runners were recruited from a staff and student population at the University of Central Lancashire. Five repetitions of shod, self-selected speed level walking and jogging were performed. Kinetic and kinematic data were collected using retro-reflective markers placed on the lower limb and foot, to create a three-segment foot model using the Calibrated Anatomical System Technique. Ankle and metatarsophalangeal moments and angles were calculated. Stiffness values were calculated using a linear best fit line of moment versus of angle plots. Paired t-tests were used to compare values between walking and jogging conditions. Significant differences were seen in ankle range of motion (ROM), but not in metatarsophalangeal ROM. Maximum moments were significantly greater in the ankle during jogging, but these were not significantly different at the metatarsophalangeal joint. Average ankle joint stiffness exhibited significantly lower stiffness when walking compared to jogging. However, the metatarsophalangeal joint exhibited significantly greater stiffness when walking compared to jogging. A greater understanding of forefoot stiffness may inform the development of footwear, prosthetic feet and orthotic devices, such as ankle-foot orthoses for walking and sporting activities.

  6. Dynamically tuned magnetostrictive spring with electrically controlled stiffness

    Science.gov (United States)

    Scheidler, Justin J.; Asnani, Vivake M.; Dapino, Marcelo J.

    2016-03-01

    This paper presents the design and testing of an electrically controllable magnetostrictive spring that has a dynamically tunable stiffness (i.e., a magnetostrictive Varispring). The device enables in situ stiffness tuning or stiffness switching for vibration control applications. Using a nonlinear electromechanical transducer model and an analytical solution of linear, mechanically induced magnetic diffusion, Terfenol-D is shown to have a faster rise time to stepped voltage inputs and a significantly higher magnetic diffusion cut-off frequency relative to Galfenol. A Varispring is manufactured using a laminated Terfenol-D rod. Further rise time reductions are achieved by minimizing the rod’s diameter and winding the electromagnet with larger wire. Dynamic tuning of the Varispring’s stiffness is investigated by measuring the Terfenol-D rod’s strain response to dynamic, compressive, axial forces in the presence of sinusoidal or square wave control currents. The Varispring’s rise time is \\lt 1 ms for 1 A current switches. Continuous modulus changes up to 21.9 GPa and 500 Hz and square wave modulus changes (dynamic {{Δ }}E effect) up to 12.3 GPa and 100 Hz are observed. Stiffness tunability and tuning bandwidth can be considerably increased by operating about a more optimal bias stress and improving the control of the electrical input.

  7. Evaluación de la estrategia de rehabilitación de base comunitaria (RBC desde la perspectiva de la comunidad y los equipos locales de rehabilitación

    Directory of Open Access Journals (Sweden)

    Alejandro Guajardo Córdoba

    2015-09-01

    Full Text Available A través de este proyecto de investigación se evalúo, desde la perspectiva de la comunidad y los equipos locales de rehabilitación en Chile, los distintos niveles de intervención de la RBC. Así, el objetivo que guío esta investigación fue evaluar el impacto social percibido y la aceptabilidad social de la estrategia de Rehabilitación de Base Comunitaria (RBC desde la perspectiva de la comunidad y los equipos locales de rehabilitación. El marco metodológico fue definido bajo los parámetros de una investigación cualitativa de carácter descriptivo y transversal. El universo de estudio correspondió a las comunas que contaban con programas de RBC que se desarrollan a nivel nacional como parte de la política nacional de discapacidad y rehabilitación en salud. Los criterios que guiaron el proceso de muestreo fueron los de pertinencia y suficiencia de la información, por lo que  se optó  por un muestreo estructural. El procesamiento de los datos se realizó mediante análisis de contenido semánticamente orientado, siguiendo una estratega intensiva, es decir, se analizó toda la información producida durante la fase de terreno. Los resultados dan cuenta de la RBC como una estrategia  con variadas formas de implementación y desarrollo que se relaciona con la historia local, el perfil de la comunidad, perfil del centro,  perfil de usuarias/ios y las características de vinculación municipal con el programa de rehabilitación. El estudio identifica en la estrategia de RBC tres modelos de acción: biomédico, biopsicosocial y comunitario.

  8. Effects of mechanical properties and geometric conditions on stiffness of Hyperboloid Shallow Shell

    Directory of Open Access Journals (Sweden)

    Zhao Lihong

    2015-01-01

    Full Text Available The experiment models based on the hyperboloid shallow shells that represent automobile panel's surface features are established. The effects of material properties and geometric conditions condition on the stiffness of hyperboloid shallow shell are investigated experimentally. The influences of panel thickness and geometric conditions on stiffness are very obvious. Stiffness increases with increasing of the panel thickness, and stiffness doubled as increasing in thickness with 0.1 mm. The effect of thickness on stiffness is far greater than that of blank holding force. The greater the arc height of punch, the greater the stiffness. And stiffness increases nearly by five times with arc height of punch is from 3mm to 9mm. The effect of arc height of punch on stiffness is far greater than that of materials mechanical properties. The stiffness is varied with different panel material properties by the same forming and stiffness test conditions. The decrease of yield strength is beneficial to the panel stiffness. The appropriate choice of materials and forming process condition is important in meeting necessary requirements for the energy-saving, lightweight and reducing wind resistance design in automotive industry.

  9. Interpenetrating network hydrogel membranes of sodium alginate and poly(vinyl alcohol) for controlled release of prazosin hydrochloride through skin.

    Science.gov (United States)

    Kulkarni, Raghavendra V; Sreedhar, V; Mutalik, Srinivas; Setty, C Mallikarjun; Sa, Biswanath

    2010-11-01

    Interpenetrating network (IPN) hydrogel membranes of sodium alginate (SA) and poly(vinyl alcohol) (PVA) were prepared by solvent casting method for transdermal delivery of an anti-hypertensive drug, prazosin hydrochloride. The prepared membranes were thin, flexible and smooth. The X-ray diffraction studies indicated the amorphous dispersion of drug in the membranes. Differential scanning calorimetric analysis confirmed the IPN formation and suggests that the membrane stiffness increases with increased concentration of glutaraldehyde (GA) in the membranes. All the membranes were permeable to water vapors depending upon the extent of cross-linking. The in vitro drug release study was performed through excised rat abdominal skin; drug release depends on the concentrations of GA in membranes. The IPN membranes extended drug release up to 24 h, while SA and PVA membranes discharged the drug quickly. The primary skin irritation and skin histopathology study indicated that the prepared IPN membranes were less irritant and safe for skin application. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Intraventricular filling under increasing left ventricular wall stiffness and heart rates

    Science.gov (United States)

    Samaee, Milad; Lai, Hong Kuan; Schovanec, Joseph; Santhanakrishnan, Arvind; Nagueh, Sherif

    2015-11-01

    Heart failure with normal ejection fraction (HFNEF) is a clinical syndrome that is prevalent in over 50% of heart failure patients. HFNEF patients show increased left ventricle (LV) wall stiffness and clinical diagnosis is difficult using ejection fraction (EF) measurements. We hypothesized that filling vortex circulation strength would decrease with increasing LV stiffness irrespective of heart rate (HR). 2D PIV and hemodynamic measurements were acquired on LV physical models of varying wall stiffness under resting and exercise HRs. The LV models were comparatively tested in an in vitro flow circuit consisting of a two-element Windkessel model driven by a piston pump. The stiffer LV models were tested in comparison with the least stiff baseline model without changing pump amplitude, circuit compliance and resistance. Increasing stiffness at resting HR resulted in diminishing cardiac output without lowering EF below 50% as in HFNEF. Increasing HR to 110 bpm in addition to stiffness resulted in lowering EF to less than 50%. The circulation strength of the intraventricular filling vortex diminished with increasing stiffness and HR. The results suggest that filling vortex circulation strength could be potentially used as a surrogate measure of LV stiffness. This research was supported by the Oklahoma Center for Advancement of Science and Technology (HR14-022).

  11. Biomechanics of hair cell kinocilia: experimental measurement of kinocilium shaft stiffness and base rotational stiffness with Euler–Bernoulli and Timoshenko beam analysis

    Science.gov (United States)

    Spoon, Corrie; Grant, Wally

    2011-01-01

    Vestibular hair cell bundles in the inner ear contain a single kinocilium composed of a 9+2 microtubule structure. Kinocilia play a crucial role in transmitting movement of the overlying mass, otoconial membrane or cupula to the mechanotransducing portion of the hair cell bundle. Little is known regarding the mechanical deformation properties of the kinocilium. Using a force-deflection technique, we measured two important mechanical properties of kinocilia in the utricle of a turtle, Trachemys (Pseudemys) scripta elegans. First, we measured the stiffness of kinocilia with different heights. These kinocilia were assumed to be homogenous cylindrical rods and were modeled as both isotropic Euler–Bernoulli beams and transversely isotropic Timoshenko beams. Two mechanical properties of the kinocilia were derived from the beam analysis: flexural rigidity (EI) and shear rigidity (kGA). The Timoshenko model produced a better fit to the experimental data, predicting EI=10,400 pN μm2 and kGA=247 pN. Assuming a homogenous rod, the shear modulus (G=1.9 kPa) was four orders of magnitude less than Young's modulus (E=14.1 MPa), indicating that significant shear deformation occurs within deflected kinocilia. When analyzed as an Euler–Bernoulli beam, which neglects translational shear, EI increased linearly with kinocilium height, giving underestimates of EI for shorter kinocilia. Second, we measured the rotational stiffness of the kinocilium insertion (κ) into the hair cell's apical surface. Following BAPTA treatment to break the kinocilial links, the kinocilia remained upright, and κ was measured as 177±47 pN μm rad–1. The mechanical parameters we quantified are important for understanding how forces arising from head movement are transduced and encoded by hair cells. PMID:21307074

  12. The effect of short-term isometric training on core/torso stiffness.

    Science.gov (United States)

    Lee, Benjamin; McGill, Stuart

    2017-09-01

    "Core" exercise is a basic part of many physical training regimens with goals ranging from rehabilitation of spine and knee injuries to improving athletic performance. Core stiffness has been proposed to perform several functions including reducing pain by minimising joint micro-movements, and enhancing strength and speed performance. This study probes the links between a training approach and immediate but temporary changes in stiffness. Passive and active stiffness was measured on 24 participants; 12 having little to no experience in core training (inexperienced), and the other 12 being athletes experienced to core training methods; before and after a 15 min bout of isometric core exercises. Passive stiffness was assessed on a "frictionless" bending apparatus and active stiffness assessed via a quick release mechanism. Short-term isometric core training increased passive and active stiffness in most directions for both inexperienced and experienced participants, passive left lateral bend among experienced participants being the exception (P core stiffness, in this case following a single session. This may influence performance and injury resilience for a brief period.

  13. Dynamic Stiffness Transfer Function of an Electromechanical Actuator Using System Identification

    Science.gov (United States)

    Kim, Sang Hwa; Tahk, Min-Jea

    2018-04-01

    In the aeroelastic analysis of flight vehicles with electromechanical actuators (EMAs), an accurate prediction of flutter requires dynamic stiffness characteristics of the EMA. The dynamic stiffness transfer function of the EMA with brushless direct current (BLDC) motor can be obtained by conducting complicated mathematical calculations of control algorithms and mechanical/electrical nonlinearities using linearization techniques. Thus, system identification approaches using experimental data, as an alternative, have considerable advantages. However, the test setup for system identification is expensive and complex, and experimental procedures for data collection are time-consuming tasks. To obtain the dynamic stiffness transfer function, this paper proposes a linear system identification method that uses information obtained from a reliable dynamic stiffness model with a control algorithm and nonlinearities. The results of this study show that the system identification procedure is compact, and the transfer function is able to describe the dynamic stiffness characteristics of the EMA. In addition, to verify the validity of the system identification method, the simulation results of the dynamic stiffness transfer function and the dynamic stiffness model were compared with the experimental data for various external loads.

  14. Martial arts training attenuates arterial stiffness in middle aged adults.

    Science.gov (United States)

    Douris, Peter C; Ingenito, Teresa; Piccirillo, Barbara; Herbst, Meredith; Petrizzo, John; Cherian, Vincen; McCutchan, Christopher; Burke, Caitlin; Stamatinos, George; Jung, Min-Kyung

    2013-09-01

    Arterial stiffness increases with age and is related to an increased risk of coronary artery disease. Poor trunk flexibility has been shown to be associated with arterial stiffness in middle-aged subjects. The purpose of our research study was to measure arterial stiffness and flexibility in healthy middle-aged martial artists compared to age and gender matched healthy sedentary controls. Ten martial artists (54.0 ± 2.0 years), who practice Soo Bahk Do (SBD), a Korean martial art, and ten sedentary subjects (54.7 ± 1.8 years) for a total of twenty subjects took part in this cross-sectional study. Arterial stiffness was assessed in all subjects using pulse wave velocity (PWV), a recognized index of arterial stiffness. Flexibility of the trunk and hamstring were also measured. The independent variables were the martial artists and matched sedentary controls. The dependent variables were PWV and flexibility. There were significant differences, between the SBD practitioners and sedentary controls, in PWV (P = 0.004), in trunk flexibility (P= 0.002), and in hamstring length (P= 0.003). The middle-aged martial artists were more flexible in their trunk and hamstrings and had less arterial stiffness compared to the healthy sedentary controls. The flexibility component of martial art training or flexibility exercises in general may be considered as a possible intervention to reduce the effects of aging on arterial stiffness.

  15. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  16. Stiffness Coefficients of Mortise and Tenon Joints used on Wooden Window Profiles

    Directory of Open Access Journals (Sweden)

    Milan Podlena

    2016-04-01

    Full Text Available Samples of corner joints of wooden rectangular windows, with widths of 78 and 92 mm, were used to determine the stiffness of tenon and mortise joints. Two series of samples were loaded statically in the angular plane of compression and tension, so that the bending moment could be derived. The objective of the experiment was to determine the existing correlations between the stiffness in maximum strength and the stiffness in the elastic area for both types of tests. After strength tests were carried out, the annual ring width of the samples was measured to determine whether this factor affects the stiffness of the joints. The results showed that there was a relatively strong correlation between the stiffness in the elastic area and the maximum load. A two-factor analysis of variance confirmed that the type of load did not affect the stiffness of the joint, but the type of joint (width does significantly affect the stiffness. Therefore, the width of annual rings was positively correlated with the stiffness of the joints.

  17. Variable stiffness and damping MR isolator

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X Z; Wang, X Y; Li, W H; Kostidis, K [University of Wollongong, School of Mechanical, Materials and Mechatronic Engineering, NSW 2522 (Australia)], E-mail: weihuali@uow.edu.au

    2009-02-01

    This paper presents the development of a magnetorheological (MR) fluid-based variable stiffness and damping isolator for vibration suppressions. The MR fluid isolator used a sole MR control unit to achieve the variable stiffness and damping in stepless and relative large scope. A mathematical model of the isolator was derived, and a prototype of the MR fluid isolator was fabricated and its dynamic behavior was measured in vibration under various applied magnetic fields. The parameters of the model under various magnetic fields were identified and the dynamic performances of isolator were evaluated.

  18. Studies on Dasyaceae. 3. Towards a phylogeny of the Dasyaceae (Ceramiales, Rhodophyta), based on comparative rbcL gene sequences and morphology

    NARCIS (Netherlands)

    de Jong, Y.S D M; van der Wurff, A.W G; Stam, W.T.; Olsen, J.L.

    Phylogenetic analyses of the Dasyaceae based on sequence analysis of the large subunit of ribulose-1,5-bisphosphate carboxylase/oxygenase (rbcL) and 42 morphological characters are presented. Comparative sequence analysis confirms the general view of the Ceramiaceae as a primitive, paraphyletic

  19. Effect of lumped mass and support stiffness on pipe seismic response

    International Nuclear Information System (INIS)

    Chang, P.S.Y.

    1986-01-01

    In performing pipe stress analysis, generic support stiffness values are typically used to predict the response of the piping systems. Consistent design of every support to match the generic stiffness value is difficult. The difference between the actual and generic stiffness may affect the results of pipe stresses and support reactions. The objective of this study is to develop an acceptance criteria for the actual support stiffness and to avoid unnecessary reanalysis. The support mass in the restraint direction and mass within the pipe span can also affect the piping system behavior and this study will discuss this mass effect as well. Added mass and change in support stiffness will cause the piping system to shift frequency

  20. Optimization of a variable-stiffness skin for morphing high-lift devices

    International Nuclear Information System (INIS)

    Thuwis, G A A; Abdalla, M M; Gürdal, Z

    2010-01-01

    One of the possibilities for the next generation of smart high-lift devices is to use a seamless morphing structure. A passive composite variable-stiffness skin as a solution to the dilemma of designing the structure to have high enough stiffness to withstand aerodynamic loading and low stiffness to enable morphing is proposed. The variable-stiffness skin is achieved by allowing for a spatial fibre angle and skin thickness variation on a morphing high-lift system. The stiffness distribution is tailored to influence the deformation of the structure beneficially. To design a realistic stiffness distribution, it is important to take aerodynamic and actuation loads into account during the optimization. A two-dimensional aero-servo-elastic framework is created for this purpose. Skin optimization is performed using a gradient-based optimizer, where sensitivity information is found through application of the adjoint method. The implementation of the aero-servo-elastic environment is addressed and initial optimization results presented. The results indicate that a variable-stiffness skin increases the design space. Moreover, the importance of taking the change in aerodynamic loads due to morphing skin deformation into account during optimization is demonstrated

  1. Accurate spring constant calibration for very stiff atomic force microscopy cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Grutzik, Scott J.; Zehnder, Alan T. [Field of Theoretical and Applied Mechanics, Cornell University, Ithaca, New York 14853 (United States); Gates, Richard S.; Gerbig, Yvonne B.; Smith, Douglas T.; Cook, Robert F. [Nanomechanical Properties Group, Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    2013-11-15

    There are many atomic force microscopy (AFM) applications that rely on quantifying the force between the AFM cantilever tip and the sample. The AFM does not explicitly measure force, however, so in such cases knowledge of the cantilever stiffness is required. In most cases, the forces of interest are very small, thus compliant cantilevers are used. A number of methods have been developed that are well suited to measuring low stiffness values. However, in some cases a cantilever with much greater stiffness is required. Thus, a direct, traceable method for calibrating very stiff (approximately 200 N/m) cantilevers is presented here. The method uses an instrumented and calibrated nanoindenter to determine the stiffness of a reference cantilever. This reference cantilever is then used to measure the stiffness of a number of AFM test cantilevers. This method is shown to have much smaller uncertainty than previously proposed methods. An example application to fracture testing of nanoscale silicon beam specimens is included.

  2. Accurate spring constant calibration for very stiff atomic force microscopy cantilevers

    International Nuclear Information System (INIS)

    Grutzik, Scott J.; Zehnder, Alan T.; Gates, Richard S.; Gerbig, Yvonne B.; Smith, Douglas T.; Cook, Robert F.

    2013-01-01

    There are many atomic force microscopy (AFM) applications that rely on quantifying the force between the AFM cantilever tip and the sample. The AFM does not explicitly measure force, however, so in such cases knowledge of the cantilever stiffness is required. In most cases, the forces of interest are very small, thus compliant cantilevers are used. A number of methods have been developed that are well suited to measuring low stiffness values. However, in some cases a cantilever with much greater stiffness is required. Thus, a direct, traceable method for calibrating very stiff (approximately 200 N/m) cantilevers is presented here. The method uses an instrumented and calibrated nanoindenter to determine the stiffness of a reference cantilever. This reference cantilever is then used to measure the stiffness of a number of AFM test cantilevers. This method is shown to have much smaller uncertainty than previously proposed methods. An example application to fracture testing of nanoscale silicon beam specimens is included

  3. Exchange stiffness of Ca-doped YIG

    Science.gov (United States)

    Avgin, I.; Huber, D. L.

    1994-05-01

    An effective medium theory for the zero-temperature exchange stiffness of uncompensated Ca-doped YIG is presented. The theory is based on the assumption that the effect of the Ca impurities is to produce strong, random ferromagnetic interactions between spins on the a and d sublattices. In the simplest version of the theory, a fraction, x, of the ad exchange integrals are large and positive, x being related to the Ca concentration. The stiffness is calculated as function of x for arbitrary perturbed ad exchange integral, Jxad. For Jxad≳(1/5)‖8Jaa+3Jdd‖, with Jaa and Jdd denoting the aa and dd exchange integrals, respectively, there is a critical concentration, Xc, such that when x≳Xc, the stiffness is complex. It is suggested that Xc delineates the region where there are significant departures from colinearity in the ground state of the Fe spins. Extension of the theory to a model where the Ca doping is assumed to generate Fe4+ ions on the tetrahedral sites is discussed. Possible experimental tests of the theory are mentioned.

  4. A multiwell platform for studying stiffness-dependent cell biology.

    Science.gov (United States)

    Mih, Justin D; Sharif, Asma S; Liu, Fei; Marinkovic, Aleksandar; Symer, Matthew M; Tschumperlin, Daniel J

    2011-01-01

    Adherent cells are typically cultured on rigid substrates that are orders of magnitude stiffer than their tissue of origin. Here, we describe a method to rapidly fabricate 96 and 384 well platforms for routine screening of cells in tissue-relevant stiffness contexts. Briefly, polyacrylamide (PA) hydrogels are cast in glass-bottom plates, functionalized with collagen, and sterilized for cell culture. The Young's modulus of each substrate can be specified from 0.3 to 55 kPa, with collagen surface density held constant over the stiffness range. Using automated fluorescence microscopy, we captured the morphological variations of 7 cell types cultured across a physiological range of stiffness within a 384 well plate. We performed assays of cell number, proliferation, and apoptosis in 96 wells and resolved distinct profiles of cell growth as a function of stiffness among primary and immortalized cell lines. We found that the stiffness-dependent growth of normal human lung fibroblasts is largely invariant with collagen density, and that differences in their accumulation are amplified by increasing serum concentration. Further, we performed a screen of 18 bioactive small molecules and identified compounds with enhanced or reduced effects on soft versus rigid substrates, including blebbistatin, which abolished the suppression of lung fibroblast growth at 1 kPa. The ability to deploy PA gels in multiwell plates for high throughput analysis of cells in tissue-relevant environments opens new opportunities for the discovery of cellular responses that operate in specific stiffness regimes.

  5. A multiwell platform for studying stiffness-dependent cell biology.

    Directory of Open Access Journals (Sweden)

    Justin D Mih

    Full Text Available Adherent cells are typically cultured on rigid substrates that are orders of magnitude stiffer than their tissue of origin. Here, we describe a method to rapidly fabricate 96 and 384 well platforms for routine screening of cells in tissue-relevant stiffness contexts. Briefly, polyacrylamide (PA hydrogels are cast in glass-bottom plates, functionalized with collagen, and sterilized for cell culture. The Young's modulus of each substrate can be specified from 0.3 to 55 kPa, with collagen surface density held constant over the stiffness range. Using automated fluorescence microscopy, we captured the morphological variations of 7 cell types cultured across a physiological range of stiffness within a 384 well plate. We performed assays of cell number, proliferation, and apoptosis in 96 wells and resolved distinct profiles of cell growth as a function of stiffness among primary and immortalized cell lines. We found that the stiffness-dependent growth of normal human lung fibroblasts is largely invariant with collagen density, and that differences in their accumulation are amplified by increasing serum concentration. Further, we performed a screen of 18 bioactive small molecules and identified compounds with enhanced or reduced effects on soft versus rigid substrates, including blebbistatin, which abolished the suppression of lung fibroblast growth at 1 kPa. The ability to deploy PA gels in multiwell plates for high throughput analysis of cells in tissue-relevant environments opens new opportunities for the discovery of cellular responses that operate in specific stiffness regimes.

  6. Generating random walks and polygons with stiffness in confinement

    International Nuclear Information System (INIS)

    Diao, Y; Ernst, C; Saarinen, S; Ziegler, U

    2015-01-01

    The purpose of this paper is to explore ways to generate random walks and polygons in confinement with a bias toward stiffness. Here the stiffness refers to the curvature angle between two consecutive edges along the random walk or polygon. The stiffer the walk (polygon), the smaller this angle on average. Thus random walks and polygons with an elevated stiffness have lower than expected curvatures. The authors introduced and studied several generation algorithms with a stiffness parameter s>0 that regulates the expected curvature angle at a given vertex in which the random walks and polygons are generated one edge at a time using conditional probability density functions. Our generating algorithms also allow the generation of unconfined random walks and polygons with any desired mean curvature angle. In the case of random walks and polygons confined in a sphere of fixed radius, we observe that, as expected, stiff random walks or polygons are more likely to be close to the confinement boundary. The methods developed here require that the random walks and random polygons be rooted at the center of the confinement sphere. (paper)

  7. Wide-range stiffness gradient PVA/HA hydrogel to investigate stem cell differentiation behavior.

    Science.gov (United States)

    Oh, Se Heang; An, Dan Bi; Kim, Tae Ho; Lee, Jin Ho

    2016-04-15

    Although stiffness-controllable substrates have been developed to investigate the effect of stiffness on cell behavior and function, the use of separate substrates with different degrees of stiffness, substrates with a narrow range stiffness gradient, toxicity of residues, different surface composition, complex fabrication procedures/devices, and low cell adhesion are still considered as hurdles of conventional techniques. In this study, a cylindrical polyvinyl alcohol (PVA)/hyaluronic acid (HA) hydrogel with a wide-range stiffness gradient (between ∼20kPa and ∼200kPa) and cell adhesiveness was prepared by a liquid nitrogen (LN2)-contacting gradual freezing-thawing method that does not use any additives or specific devices to produce the stiffness gradient hydrogel. From an in vitro cell culture using the stiffness gradient PVA/HA hydrogel, it was observed that human bone marrow mesenchymal stem cells have favorable stiffness ranges for induction of differentiation into specific cell types (∼20kPa for nerve cell, ∼40kPa for muscle cell, ∼80kPa for chondrocyte, and ∼190kPa for osteoblast). The PVA/HA hydrogel with a wide range of stiffness spectrum can be a useful tool for basic studies related with the stem cell differentiation, cell reprogramming, cell migration, and tissue regeneration in terms of substrate stiffness. It is postulated that the stiffness of the extracellular matrix influences cell behavior. To prove this concept, various techniques to prepare substrates with a stiffness gradient have been developed. However, the narrow ranges of stiffness gradient and complex fabrication procedures/devices are still remained as limitations. Herein, we develop a substrate (hydrogel) with a wide-range stiffness gradient using a gradual freezing-thawing method which does not need specific devices to produce a stiffness gradient hydrogel. From cell culture experiments using the hydrogel, it is observed that human bone marrow mesenchymal stem cells have

  8. Optimization of a variable-stiffness skin for morphing high-lift devices

    NARCIS (Netherlands)

    Thuwis, G.A.A.; Abdalla, M.M.; Gürdal, Z.

    2010-01-01

    One of the possibilities for the next generation of smart high-lift devices is to use a seamless morphing structure. A passive composite variable-stiffness skin as a solution to the dilemma of designing the structure to have high enough stiffness to withstand aerodynamic loading and low stiffness to

  9. Design of a Variable Stiffness Soft Dexterous Gripper

    Science.gov (United States)

    Nefti-Meziani, Samia; Davis, Steve

    2017-01-01

    Abstract This article presents the design of a variable stiffness, soft, three-fingered dexterous gripper. The gripper uses two designs of McKibben muscles. Extensor muscles that increase in length when pressurized are used to form the fingers of the gripper. Contractor muscles that decrease in length when pressurized are then used to apply forces to the fingers through tendons, which cause flexion and extension of the fingers. The two types of muscles are arranged to act antagonistically and this means that by raising the pressure in all of the pneumatic muscles, the stiffness of the system can be increased without a resulting change in finger position. The article presents the design of the gripper, some basic kinematics to describe its function, and then experimental results demonstrating the ability to adjust the bending stiffness of the gripper's fingers. It has been demonstrated that the fingers' bending stiffness can be increased by more than 150%. The article concludes by demonstrating that the fingers can be closed loop position controlled and are able to track step and sinusoidal inputs. PMID:29062630

  10. Bone metabolism and arterial stiffness after renal transplantation.

    Science.gov (United States)

    Cseprekál, Orsolya; Kis, Eva; Dégi, Arianna A; Kerti, Andrea; Szabó, Attila J; Reusz, György S

    2014-01-01

    To assess the relationship between bone and vascular disease and its changes over time after renal transplantation. Metabolic bone disease (MBD) is common in chronic kidney disease (CKD) and is associated with cardiovascular (CV) disease. Following transplantation (Tx), improvement in CV disease has been reported; however, data regarding changes in bone disease remain controversial. Bone turnover and arterial stiffness (pulse wave velocity (PWV)) were assessed in 47 Tx patients (38 (3-191) months after Tx). Bone alkaline phosphatase (BALP), osteocalcin (OC) and beta-crosslaps were significantly higher in Tx patients, and decreased significantly after one year. There was a negative correlation between BALP, OC and steroid administered (r = -0.35; r = -0.36 respectively). PWV increased in the Tx group (1.15 SD). In patients with a follow up of bone turnover and arterial stiffness are present following kidney transplantation. While bone turnover decreases with time, arterial stiffness correlates initially with bone turnover, after which the influence of cholesterol becomes significant. Non-invasive estimation of bone metabolism and arterial stiffness may help to assess CKD-MBD following renal transplantation.

  11. Evidence for a Role for the Plasma Membrane in the Nanomechanical Properties of the Cell Wall as Revealed by an Atomic Force Microscopy Study of the Response of Saccharomyces cerevisiae to Ethanol Stress.

    Science.gov (United States)

    Schiavone, Marion; Formosa-Dague, Cécile; Elsztein, Carolina; Teste, Marie-Ange; Martin-Yken, Helene; De Morais, Marcos A; Dague, Etienne; François, Jean M

    2016-08-01

    A wealth of biochemical and molecular data have been reported regarding ethanol toxicity in the yeast Saccharomyces cerevisiae However, direct physical data on the effects of ethanol stress on yeast cells are almost nonexistent. This lack of information can now be addressed by using atomic force microscopy (AFM) technology. In this report, we show that the stiffness of glucose-grown yeast cells challenged with 9% (vol/vol) ethanol for 5 h was dramatically reduced, as shown by a 5-fold drop of Young's modulus. Quite unexpectedly, a mutant deficient in the Msn2/Msn4 transcription factor, which is known to mediate the ethanol stress response, exhibited a low level of stiffness similar to that of ethanol-treated wild-type cells. Reciprocally, the stiffness of yeast cells overexpressing MSN2 was about 35% higher than that of the wild type but was nevertheless reduced 3- to 4-fold upon exposure to ethanol. Based on these and other data presented herein, we postulated that the effect of ethanol on cell stiffness may not be mediated through Msn2/Msn4, even though this transcription factor appears to be a determinant in the nanomechanical properties of the cell wall. On the other hand, we found that as with ethanol, the treatment of yeast with the antifungal amphotericin B caused a significant reduction of cell wall stiffness. Since both this drug and ethanol are known to alter, albeit by different means, the fluidity and structure of the plasma membrane, these data led to the proposition that the cell membrane contributes to the biophysical properties of yeast cells. Ethanol is the main product of yeast fermentation but is also a toxic compound for this process. Understanding the mechanism of this toxicity is of great importance for industrial applications. While most research has focused on genomic studies of ethanol tolerance, we investigated the effects of ethanol at the biophysical level and found that ethanol causes a strong reduction of the cell wall rigidity (or

  12. Evidence for a Role for the Plasma Membrane in the Nanomechanical Properties of the Cell Wall as Revealed by an Atomic Force Microscopy Study of the Response of Saccharomyces cerevisiae to Ethanol Stress

    Science.gov (United States)

    Schiavone, Marion; Formosa-Dague, Cécile; Elsztein, Carolina; Teste, Marie-Ange; Martin-Yken, Helene; De Morais, Marcos A.; Dague, Etienne

    2016-01-01

    ABSTRACT A wealth of biochemical and molecular data have been reported regarding ethanol toxicity in the yeast Saccharomyces cerevisiae. However, direct physical data on the effects of ethanol stress on yeast cells are almost nonexistent. This lack of information can now be addressed by using atomic force microscopy (AFM) technology. In this report, we show that the stiffness of glucose-grown yeast cells challenged with 9% (vol/vol) ethanol for 5 h was dramatically reduced, as shown by a 5-fold drop of Young's modulus. Quite unexpectedly, a mutant deficient in the Msn2/Msn4 transcription factor, which is known to mediate the ethanol stress response, exhibited a low level of stiffness similar to that of ethanol-treated wild-type cells. Reciprocally, the stiffness of yeast cells overexpressing MSN2 was about 35% higher than that of the wild type but was nevertheless reduced 3- to 4-fold upon exposure to ethanol. Based on these and other data presented herein, we postulated that the effect of ethanol on cell stiffness may not be mediated through Msn2/Msn4, even though this transcription factor appears to be a determinant in the nanomechanical properties of the cell wall. On the other hand, we found that as with ethanol, the treatment of yeast with the antifungal amphotericin B caused a significant reduction of cell wall stiffness. Since both this drug and ethanol are known to alter, albeit by different means, the fluidity and structure of the plasma membrane, these data led to the proposition that the cell membrane contributes to the biophysical properties of yeast cells. IMPORTANCE Ethanol is the main product of yeast fermentation but is also a toxic compound for this process. Understanding the mechanism of this toxicity is of great importance for industrial applications. While most research has focused on genomic studies of ethanol tolerance, we investigated the effects of ethanol at the biophysical level and found that ethanol causes a strong reduction of the cell

  13. The protective effect of aqueous extracts of roselle (Hibiscus sabdariffa L. UKMR-2) against red blood cell membrane oxidative stress in rats with streptozotocin-induced diabetes

    OpenAIRE

    Mohamed, Jamaludin; Shing, Saw Wuan; Idris, Muhd Hanis Md; Budin, Siti Balkis; Zainalabidin, Satirah

    2013-01-01

    OBJECTIVES: The aim of this study was to investigate the protective effects of aqueous extracts of roselle (Hibiscus sabdariffa L. UKMR-2) against red blood cell (RBC) membrane oxidative stress in rats with streptozotocin-induced diabetes. METHODS: Forty male Sprague-Dawley rats weighing 230-250 g were randomly divided into four groups (n = 10 rats each): control group (N), roselle-treated control group, diabetic group, and roselle-treated diabetic group. Roselle was administered by force-f...

  14. Identification of a parametric, discrete-time model of ankle stiffness.

    Science.gov (United States)

    Guarin, Diego L; Jalaleddini, Kian; Kearney, Robert E

    2013-01-01

    Dynamic ankle joint stiffness defines the relationship between the position of the ankle and the torque acting about it and can be separated into intrinsic and reflex components. Under stationary conditions, intrinsic stiffness can described by a linear second order system while reflex stiffness is described by Hammerstein system whose input is delayed velocity. Given that reflex and intrinsic torque cannot be measured separately, there has been much interest in the development of system identification techniques to separate them analytically. To date, most methods have been nonparametric and as a result there is no direct link between the estimated parameters and those of the stiffness model. This paper presents a novel algorithm for identification of a discrete-time model of ankle stiffness. Through simulations we show that the algorithm gives unbiased results even in the presence of large, non-white noise. Application of the method to experimental data demonstrates that it produces results consistent with previous findings.

  15. Hemoglobin redox reactions and red blood cell aging.

    Science.gov (United States)

    Rifkind, Joseph M; Nagababu, Enika

    2013-06-10

    The physiological mechanism(s) for recognition and removal of red blood cells (RBCs) from circulation after 120 days of its lifespan is not fully understood. Many of the processes thought to be associated with the removal of RBCs involve oxidative stress. We have focused on hemoglobin (Hb) redox reactions, which is the major source of RBC oxidative stress. The importance of Hb redox reactions have been shown to originate in large parts from the continuous slow autoxidation of Hb producing superoxide and its dramatic increase under hypoxic conditions. In addition, oxidative stress has been shown to be associated with redox reactions that originate from Hb reactions with nitrite and nitric oxide (NO) and the resultant formation of highly toxic peroxynitrite when NO reacts with superoxide released during Hb autoxidation. The interaction of Hb, particularly under hypoxic conditions with band 3 of the RBC membrane is critical for the generating the RBC membrane changes that trigger the removal of cells from circulation. These changes include exposure of antigenic sites, increased calcium leakage into the RBC, and the resultant leakage of potassium out of the RBC causing cell shrinkage and impaired deformability. The need to understand the oxidative damage to specific membrane proteins that result from redox reactions occurring when Hb is bound to the membrane. Proteomic studies that can pinpoint the specific proteins damaged under different conditions will help elucidate the cellular aging processes that result in cells being removed from circulation.

  16. Extension of elastic stiffness formula for leaf type holddown spring assembly

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kee Nam; Kang, Heung Seok; Yoon, Kyung Ho; Kim, Hyung Kyu [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-09-01

    Based on the Euler beam theory and the strain energy method, an elastic stiffness formula of the holddown spring assembly consisting of several leaves was previously derived. The formula was known to be useful to estimate the elastic stiffness of the holddown spring assembly only with the geometric data and the material properties of the leaf. Recently, it was reported that the elastic stiffness from the formula deviated much from the test results as the number of leaves was increased. In this study, in order to resolve such an increasing deviation as the increasing number of leaves, the formula has been extended to be able to consider normal forces and friction forces acting on interfaces between the leaves. The elastic stiffness analysis on specimens of leaf type holddown springs has been carried out using the extended formula and the analysis results are compared with the test results. As a result of comparisons, it is found that the extended formula is able to evaluate the elastic stiffness of the holddown spring assembly within an error range of 10%, irrespective of the number of leaves. In addition, it is found that the effect of shear forces and axial forces on the elastic stiffness of the holddown spring assembly is only below 0.2% of the elastic stiffness, and therefore the greatest portion of the elastic stiffness of the holddown spring assembly is attributed to the bending moment. (author). 13 refs., 10 figs., 12 tabs.

  17. Dynamic Functional Stiffness Index of the Ankle Joint During Daily Living.

    Science.gov (United States)

    Argunsah Bayram, Hande; Bayram, Mehmed B

    2018-03-30

    Exploring ankle joint physiologic functional stiffness is crucial for improving the design of prosthetic feet that aim to mimic normal gait. We hypothesized that ankle joint stiffness would vary among the different activities of daily living and that the magnitude of the stiffness would indicate the degree of energy storage element sufficiency in terms of harvesting and returning energy. We examined sagittal plane ankle moment versus flexion angle curves from 12 healthy subjects during the daily activities. The slopes of these curves were assessed to find the calculated stiffness during the peak energy return and harvest phases. For the energy return and harvest phases, stiffness varied from 0.016 to 0.283 Nm/kg° and 0.025 and 0.858 Nm/kg°, respectively. The optimum stiffness during the energy return phase was 0.111 ± 0.117 Nm/kg° and during the energy harvest phase was 0.234 ± 0.327 Nm/kg°. Ankle joint stiffness varied significantly during the activities of daily living, indicating that an energy storage unit with a constant stiffness would not be sufficient in providing energy regenerative gait during all activities. The present study was directed toward the development of a complete data set to determine the torque-angle properties of the ankle joint to facilitate a better design process. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Parametric study of roof diaphragm stiffness requirements

    International Nuclear Information System (INIS)

    Jones, W.D.; Tenbus, M.A.

    1991-01-01

    A common assumption made in performing a dynamic seismic analysis for a building is that the roof/floor system is open-quotes rigidclose quotes. This assumption would appear to be reasonable for many of the structures found in nuclear power plants, since many of these structures are constructed of heavily reinforced concrete having floor/roof slabs at least two feet in thickness, and meet the code requirements for structural detailing for seismic design. The roofs of many Department of Energy (DOE) buildings at the Oak Ridge Y-12 Plant in Oak Ridge, Tennessee, have roofs constructed of either metal, precast concrete or gypsum plank deck overlaid with rigid insulation, tar and gravel. In performing natural phenomena hazard assessments for one such facility, it was assumed that the existing roof performed first as a flexible diaphragm (zero stiffness) and then, rigid (infinitely stiff). For the flexible diaphragm model it was determined that the building began to experience significant damage around 0.09 g's. For the rigid diaphragm model it was determined that no significant damage was observed below 0.20 g's. A Conceptual Design Report has been prepared for upgrading/replacing the roof of this building. The question that needed to be answered here was, open-quotes How stiff should the new roof diaphragm be in order to satisfy the rigid diaphragm assumption and, yet, be cost effective?close quotes. This paper presents a parametric study of a very simple structural system to show that the design of roof diaphragms needs to consider both strength and stiffness (frequency) requirements. This paper shows how the stiffness of a roof system affects the seismically induced loads in the lateral, vertical load resisting elements of a building and provides guidance in determining how open-quotes rigidclose quotes a roof system should be in order to accomplish a cost effective design

  19. R and G color component competition of RGB image decomposition as a criterion to register RBC agglutinates for blood group typing.

    Science.gov (United States)

    Doubrovski, Valeri A; Ganilova, Yuliya A; Zabenkov, Igor V

    2014-03-01

    A new approach of the criterion assignment for registration of erythrocyte agglutinates to instrumentally determine blood group type is suggested. The criterion is based on comparison of R and G components of RGB decomposition of microscopy digital image taken for the blood-serum mixture sample. For the chosen experimental conditions, the minimal size (area) of RBC agglutinate to be registered by the criterion suggested is estimated theoretically. The proposed method was tested experimentally on the example of monitoring agglutinates in flow. The encouraging experimental results were obtained for improvement of the resolving power of the method; the optimal experimental conditions were revealed for maximum resolution. Though the suggested method was realized for dynamic (flow) blood group determination, it could also be applied for diagnostics in a stationary environment. This approach increases the reliability of RBC agglutinates registration and, hence, blood group typing. The results may be used to develop the apparatus for automated determination of human blood group.

  20. Comparative study of diastolic filling under varying left ventricular wall stiffness

    Science.gov (United States)

    Mekala, Pritam; Santhanakrishnan, Arvind

    2014-11-01

    Pathological remodeling of the human cardiac left ventricle (LV) is observed in hypertensive heart failure as a result of pressure overload. Myocardial stiffening occurs in these patients prior to chronic maladaptive changes, resulting in increased LV wall stiffness. The goal of this study was to investigate the change in intraventricular filling fluid dynamics inside a physical model of the LV as a function of wall stiffness. Three LV models of varying wall stiffness were incorporated into an in vitro flow circuit driven by a programmable piston pump. Windkessel elements were used to tune the inflow and systemic pressure in the model with least stiffness to match healthy conditions. Models with stiffer walls were comparatively tested maintaining circuit compliance, resistance and pump amplitude constant. 2D phase-locked PIV measurements along the central plane showed that with increase in wall stiffness, the peak velocity and cardiac output inside the LV decreased. Further, inflow vortex ring propagation toward the LV apex was reduced with increasing stiffness. The above findings indicate the importance of considering LV wall relaxation characteristics in pathological studies of filling fluid dynamics.

  1. Leg stiffness during phases of countermovement and take-off in vertical jump.

    Science.gov (United States)

    Struzik, Artur; Zawadzki, Jerzy

    2013-01-01

    With respect to cyclic movements such as human gait, running or hopping, leg stiffness is a little variable parameter. The aim of this study was to investigate changes in leg stiffness during the phase of countermovement and take-off when performing a single maximum counter-movement jump. Kistler force plates and a BTS SMART system for comprehensive motion analysis were employed in the study. The study covered a group of 12 athletes from university basketball teams. Leg stiffness was calculated in those parts of countermovement and take-off phases where its level is relatively constant and the relationship F(Δl) is similar to linear one. Mean total stiffness (±SD) in both legs in the countermovement phase amounted to 6.5 ± 1.5 kN/m, whereas during the take-off phase this value was 6.9 ± 1 kN/m. No statistically significant differences were found between leg stiffness during the countermovement phase and takeoff phase in the study group at the level of significance set at α = 0.05. This suggests that the leg stiffness in phase of countermovement and phase of take-off are much similar to each other, despite different function of both phases. Similar to cyclic movements, leg stiffness turned out relatively constant when performing a single vertical jump. There are also reported statistically significant correlations between body mass, body height, length of lower limbs and leg stiffness. The stiffness analysed by the authors should be understood as quasi-stiffness because the measurements of ΔF(Δl) were made during transient states where inertia and dumping forces are likely to affect the final result.

  2. Critical appraisal of the differential effects of antihypertensive agents on arterial stiffness

    Directory of Open Access Journals (Sweden)

    Francesca Kum

    2010-06-01

    Full Text Available Francesca Kum, Janaka KarallieddeUnit for Metabolic Medicine, Cardiovascular Division, Kings College-Waterloo Campus, King’s College London, United KingdomAbstract: Increased central arterial stiffness, involving accelerated vascular ageing of the aorta, is a powerful and independent risk factor for early mortality and provides prognostic information above and beyond traditional risk factors for cardiovascular disease (CVD. Central arterial stiffness is an important determinant of pulse pressure; therefore, any pathological increase may result in left ventricular hypertrophy and impaired coronary perfusion. Central artery stiffness can be assessed noninvasively by measurement of aortic pulse wave velocity, which is the gold standard for measurement of arterial stiffness. Earlier, it was believed that changes in arterial stiffness, which are primarily influenced by long-term pressure-dependent structural changes, may be slowed but not reversed by pharmacotherapy. Recent studies with drugs that inhibit the renin–angiotensin–aldosterone system, advanced glycation end products crosslink breakers, and endothelin antagonists suggest that blood pressure (BP-independent reduction and reversal of arterial stiffness are feasible. We review the recent literature on the differential effect of antihypertensive agents either as monotherapy or combination therapy on arterial stiffness. Arterial stiffness is an emerging therapeutic target for CVD risk reduction; however, further clinical trials are required to confirm whether BP-independent changes in arterial stiffness directly translate to a reduction in CVD events.Keywords: aortic pulse wave velocity, augmentation index, blood pressure, renin–angiotensin–aldosterone system

  3. A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Lim, Seok Tae; Kim, Dong Wook; Yim, Chang Yeol [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

  4. Flexural Stiffness of Myosin Va Subdomains as Measured from Tethered Particle Motion

    Science.gov (United States)

    Michalek, Arthur J.; Kennedy, Guy G.; Warshaw, David M.; Ali, M. Yusuf

    2015-01-01

    Myosin Va (MyoVa) is a processive molecular motor involved in intracellular cargo transport on the actin cytoskeleton. The motor's processivity and ability to navigate actin intersections are believed to be governed by the stiffness of various parts of the motor's structure. Specifically, changes in calcium may regulate motor processivity by altering the motor's lever arm stiffness and thus its interhead communication. In order to measure the flexural stiffness of MyoVa subdomains, we use tethered particle microscopy, which relates the Brownian motion of fluorescent quantum dots, which are attached to various single- and double-headed MyoVa constructs bound to actin in rigor, to the motor's flexural stiffness. Based on these measurements, the MyoVa lever arm and coiled-coil rod domain have comparable flexural stiffness (0.034 pN/nm). Upon addition of calcium, the lever arm stiffness is reduced 40% as a result of calmodulins potentially dissociating from the lever arm. In addition, the flexural stiffness of the full-length MyoVa construct is an order of magnitude less stiff than both a single lever arm and the coiled-coil rod. This suggests that the MyoVa lever arm-rod junction provides a flexible hinge that would allow the motor to maneuver cargo through the complex intracellular actin network. PMID:26770194

  5. Technical Validation of ARTSENS–An Image Free Device for Evaluation of Vascular Stiffness

    Science.gov (United States)

    Radhakrishnan, Ravikumar; Kusmakar, Shitanshu; Thrivikraman, Arya Sree; Sivaprakasam, Mohanasankar

    2015-01-01

    Vascular stiffness is an indicator of cardiovascular health, with carotid artery stiffness having established correlation to coronary heart disease and utility in cardiovascular diagnosis and screening. State of art equipment for stiffness evaluation are expensive, require expertise to operate and not amenable for field deployment. In this context, we developed ARTerial Stiffness Evaluation for Noninvasive Screening (ARTSENS), a device for image free, noninvasive, automated evaluation of vascular stiffness amenable for field use. ARTSENS has a frugal hardware design, utilizing a single ultrasound transducer to interrogate the carotid artery, integrated with robust algorithms that extract arterial dimensions and compute clinically accepted measures of arterial stiffness. The ability of ARTSENS to measure vascular stiffness in vivo was validated by performing measurements on 125 subjects. The accuracy of results was verified with the state-of-the-art ultrasound imaging-based echo-tracking system. The relation between arterial stiffness measurements performed in sitting posture for ARTSENS measurement and sitting/supine postures for imaging system was also investigated to examine feasibility of performing ARTSENS measurements in the sitting posture for field deployment. This paper verified the feasibility of the novel ARTSENS device in performing accurate in vivo measurements of arterial stiffness. As a portable device that performs automated measurement of carotid artery stiffness with minimal operator input, ARTSENS has strong potential for use in large-scale screening. PMID:27170892

  6. Superfluid phase stiffness in electron doped superconducting Gd-123

    Science.gov (United States)

    Das, P.; Ghosh, Ajay Kumar

    2018-05-01

    Current-voltage characteristics of Ce substituted Gd-123 superconductor exhibits nonlinearity below a certain temperature below the critical temperature. An exponent is extracted using the nonlinearity of current-voltage relation. Superfluid phase stiffness has been studied as a function of temperature following the Ambegaokar-Halperin-Nelson-Siggia (AHNS) theory. Phase stiffness of the superfluid below the superconducting transition is found to be sensitive to the change in the carrier concentration in superconducting system. There may be a crucial electron density which affects superfluid stiffness strongly. Electron doping is found to be effective even if the coupling of the superconducting planes is changed.

  7. Variable stiffness corrugated composite structure with shape memory polymer for morphing skin applications

    Science.gov (United States)

    Gong, Xiaobo; Liu, Liwu; Scarpa, Fabrizio; Leng, Jinsong; Liu, Yanju

    2017-03-01

    This work presents a variable stiffness corrugated structure based on a shape memory polymer (SMP) composite with corrugated laminates as reinforcement that shows smooth aerodynamic surface, extreme mechanical anisotropy and variable stiffness for potential morphing skin applications. The smart composite corrugated structure shows a low in-plane stiffness to minimize the actuation energy, but also possess high out-of-plane stiffness to transfer the aerodynamic pressure load. The skin provides an external smooth aerodynamic surface because of the one-sided filling with the SMP. Due to variable stiffness of the shape memory polymer the morphing skin exhibits a variable stiffness with a change of temperature, which can help the skin adjust its stiffness according different service environments and also lock the temporary shape without external force. Analytical models related to the transverse and bending stiffness are derived and validated using finite element techniques. The stiffness of the morphing skin is further investigated by performing a parametric analysis against the geometry of the corrugation and various sets of SMP fillers. The theoretical and numerical models show a good agreement and demonstrate the potential of this morphing skin concept for morphing aircraft applications. We also perform a feasibility study of the use of this morphing skin in a variable camber morphing wing baseline. The results show that the morphing skin concept exhibits sufficient bending stiffness to withstand the aerodynamic load at low speed (less than 0.3 Ma), while demonstrating a large transverse stiffness variation (up to 191 times) that helps to create a maximum mechanical efficiency of the structure under varying external conditions.

  8. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    Science.gov (United States)

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Water retention properties of stiff silt

    Directory of Open Access Journals (Sweden)

    Barbara Likar

    2017-06-01

    Full Text Available Recent research into the behaviour of soils has shown that it is in fact much more complex than can be described by the mechanics of saturated soils. Nowadays the trend of investigations has shifted towards the unsaturated state. Despite the signifiant progress that has been made so far, there are still a lot of unanswered questions related to the behaviour of unsaturated soils. For this reason, in the fild of geotechnics some new concepts are developed, which include the study of soil suction. Most research into soil suction has involved clayey and silty material, whereas up until recently no data have been available about measurements in very stiff preconsolidated sandy silt. Very stiff preconsolidated sandy silt is typical of the Krško Basin, where it is planned that some very important geotechnical structures will be built, so that knowledge about the behaviour of such soils at increased or decreased water content is essential. Several different methods can be used for soil suction measurements. In the paper the results of measurements carried out on very stiff preconsolidated sandy silt in a Bishop - Wesley double-walled triaxial cell are presented and compared with the results of soil suction measurements performed by means of a potentiometer (WP4C. All the measurement results were evaluated taking into account already known results given in the literature, using the three most commonly used mathematical models. Until now a lot of papers dealing with suction measurements in normal consolidated and preconsolidated clay have been published. Measurements on very stiff preconsolidated sandy silt, as presented in this paper were not supported before.

  10. Modelling, simulation and experiment of the spherical flexible joint stiffness

    Directory of Open Access Journals (Sweden)

    S. Li

    2018-02-01

    Full Text Available The spherical flexible joint is extensively used in engineering. It is designed to provide flexibility in rotation while bearing vertical compression load. The linear rotational stiffness of the flexible joint is formulated. The rotational stiffness of the bonded rubber layer is related to inner radius, thickness and two edge angles. FEM is used to verify the analytical solution and analyze the stiffness. The Mooney–Rivlin, Neo Hooke and Yeoh constitutive models are used in the simulation. The experiment is taken to obtain the material coefficient and validate the analytical and FEM results. The Yeoh model can reflect the deformation trend more accurately, but the error in the nearly linear district is bigger than the Mooney–Rivlin model. The Mooney–Rivlin model can fit the test result very well and the analytical solution can also be used when the rubber deformation in the flexible joint is small. The increase of Poisson's ratio of the rubber layers will enhance the vertical compression stiffness but barely have effect on the rotational stiffness.

  11. In vivo determination of hepatic stiffness using steady-state free precession magnetic resonance elastography.

    Science.gov (United States)

    Klatt, Dieter; Asbach, Patrick; Rump, Jens; Papazoglou, Sebastian; Somasundaram, Rajan; Modrow, Jens; Braun, Jürgen; Sack, Ingolf

    2006-12-01

    The objective of this study was to introduce an magnetic resonance elastography (MRE) protocol based on fractional motion encoding and planar wave acquisition for rapid measurements of in vivo human liver stiffness. Vibrations of a remote actuator membrane were fed by a rigid rod to the patient's surface beneath the right costal arch resulting in axial shear deflections of the liver. Data acquisition was performed using a balanced steady-state free precession (bSSFP) sequence incorporating oscillating gradients for motion sensitization. Tissue vibrations of frequency fv = 51 Hz were tuned by twice the sequence repetition time (1/fv = 2TR). Twenty axial images acquired by time-resolved through-plane wave encoding were used for planar elasticity reconstruction. The MRE data acquisition was achieved within 4 breathholds of 17 seconds each. The method was applied to 12 healthy volunteers and 2 patients with diffuse liver disease (fibrosis grade 3). MRE data acquisition was successful in all volunteers and patients. The elastic moduli were measured with values between 1.99 +/- 0.16 and 5.77 +/- 0.88 kPa. Follow-up studies demonstrated the reproducibility of the method and revealed a difference of 0.74 +/- 0.47 kPa (P analysis of the strain wave field captured by axial wave images. The measured data indicate individual variations of hepatic stiffness in healthy volunteers.

  12. A METHOD OF DETERMINING THE COORDINATES OF THE STIFFNESS CENTER AND THE STIFFNESS PRINCIPAL AXIS OF THE VIBRATING SYSTEM WITH DAMPING

    OpenAIRE

    Dang Xuan Truong; Tran Duc Chinh

    2014-01-01

    The report presents a methodology to determine the directions of the stiffness principal axis (in this case subject to the linear displacement and forced rotation angle) of a solid object interact with the surrounding environment by resilient bearing supports. The results also show that determining the coordinates of the stiffness center in the vibrating system with damping factors is necessary in our research.

  13. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding...... soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients...... for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been...

  14. Single-cell mechanics--An experimental-computational method for quantifying the membrane-cytoskeleton elasticity of cells.

    Science.gov (United States)

    Tartibi, M; Liu, Y X; Liu, G-Y; Komvopoulos, K

    2015-11-01

    The membrane-cytoskeleton system plays a major role in cell adhesion, growth, migration, and differentiation. F-actin filaments, cross-linkers, binding proteins that bundle F-actin filaments to form the actin cytoskeleton, and integrins that connect the actin cytoskeleton network to the cell plasma membrane and extracellular matrix are major cytoskeleton constituents. Thus, the cell cytoskeleton is a complex composite that can assume different shapes. Atomic force microscopy (AFM)-based techniques have been used to measure cytoskeleton material properties without much attention to cell shape. A recently developed surface chemical patterning method for long-term single-cell culture was used to seed individual cells on circular patterns. A continuum-based cell model, which uses as input the force-displacement response obtained with a modified AFM setup and relates the membrane-cytoskeleton elastic behavior to the cell geometry, while treating all other subcellular components suspended in the cytoplasmic liquid (gel) as an incompressible fluid, is presented and validated by experimental results. The developed analytical-experimental methodology establishes a framework for quantifying the membrane-cytoskeleton elasticity of live cells. This capability may have immense implications in cell biology, particularly in studies seeking to establish correlations between membrane-cytoskeleton elasticity and cell disease, mortality, differentiation, and migration, and provide insight into cell infiltration through nonwoven fibrous scaffolds. The present method can be further extended to analyze membrane-cytoskeleton viscoelasticity, examine the role of other subcellular components (e.g., nucleus envelope) in cell elasticity, and elucidate the effects of mechanical stimuli on cell differentiation and motility. This is the first study to decouple the membrane-cytoskeleton elasticity from cell stiffness and introduce an effective approach for measuring the elastic modulus. The

  15. Finding trap stiffness of optical tweezers using digital filters.

    Science.gov (United States)

    Almendarez-Rangel, Pedro; Morales-Cruzado, Beatriz; Sarmiento-Gómez, Erick; Pérez-Gutiérrez, Francisco G

    2018-02-01

    Obtaining trap stiffness and calibration of the position detection system is the basis of a force measurement using optical tweezers. Both calibration quantities can be calculated using several experimental methods available in the literature. In most cases, stiffness determination and detection system calibration are performed separately, often requiring procedures in very different conditions, and thus confidence of calibration methods is not assured due to possible changes in the environment. In this work, a new method to simultaneously obtain both the detection system calibration and trap stiffness is presented. The method is based on the calculation of the power spectral density of positions through digital filters to obtain the harmonic contributions of the position signal. This method has the advantage of calculating both trap stiffness and photodetector calibration factor from the same dataset in situ. It also provides a direct method to avoid unwanted frequencies that could greatly affect calibration procedure, such as electric noise, for example.

  16. Potential Relationship between Passive Plantar Flexor Stiffness and Running Performance.

    Science.gov (United States)

    Ueno, Hiromasa; Suga, Tadashi; Takao, Kenji; Tanaka, Takahiro; Misaki, Jun; Miyake, Yuto; Nagano, Akinori; Isaka, Tadao

    2018-02-01

    The present study aimed to determine the relationship between passive stiffness of the plantar flexors and running performance in endurance runners. Forty-eight well-trained male endurance runners and 24 untrained male control subjects participated in this study. Plantar flexor stiffness during passive dorsiflexion was calculated from the slope of the linear portion of the torque-angle curve. Of the endurance runners included in the present study, running economy in 28 endurance runners was evaluated by measuring energy cost during three 4-min trials (14, 16, and 18 km/h) of submaximal treadmill running. Passive stiffness of the plantar flexors was significantly higher in endurance runners than in untrained subjects. Moreover, passive plantar flexor stiffness in endurance runners was significantly correlated with a personal best 5000-m race time. Furthermore, passive plantar flexor stiffness in endurance runners was significantly correlated with energy cost during submaximal running at 16 km/h and 18 km/h, and a trend towards such significance was observed at 14 km/h. The present findings suggest that stiffer plantar flexors may help achieve better running performance, with greater running economy, in endurance runners. Therefore, in the clinical setting, passive stiffness of the plantar flexors may be a potential parameter for assessing running performance. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Pathogen inactivation by riboflavin and ultraviolet light illumination accelerates the red blood cell storage lesion and promotes eryptosis.

    Science.gov (United States)

    Qadri, Syed M; Chen, Deborah; Schubert, Peter; Perruzza, Darian L; Bhakta, Varsha; Devine, Dana V; Sheffield, William P

    2017-03-01

    Pathogen reduction treatment using riboflavin and ultraviolet light illumination (Mirasol) effectively reduces the risk of transfusion-transmitted infections. This treatment is currently licensed for only platelets and plasma products, while its application to whole blood (WB) to generate pathogen-inactivated red blood cells (RBCs) is under development. RBC storage lesion, constituting numerous morphologic and biochemical changes, influences RBC quality and limits shelf life. Stored RBCs further show enhanced susceptibility to RBC programmed cell death (eryptosis) characterized by increased cytosolic Ca 2+ -provoked membrane phosphatidylserine (PS) externalization. Using a "pool-and-split" approach, we examined multiple variables of RBC storage lesion and eryptosis in RBC units, derived from Mirasol-treated or untreated WB, after 4 to 42 days of storage, under blood bank conditions. In comparison to untreated RBC units, Mirasol treatment significantly altered membrane microvesiculation, supernatant hemoglobin, osmotic fragility, and intracellular adenosine triphosphate levels but did not influence membrane CD47 expression and 2,3-diphosphoglycerate levels. Mirasol-treated RBCs showed significantly higher PS exposure after 42, but not after not more than 21, days of storage, which was accompanied by enhanced cytosolic Ca 2+ activity, ceramide abundance, and oxidative stress, but not p38 kinase activation. Mirasol treatment significantly augmented PS exposure, Ca 2+ entry, and protein kinase C activation after energy depletion, a pathophysiologic cell stressor. Mirasol-treated RBCs were, however, more resistant to cell shrinkage. Prolonged storage of Mirasol-treated RBCs significantly increases the proportion of eryptotic RBCs, while even short-term storage enhances the susceptibility of RBCs to stress-induced eryptosis, which could reduce posttransfusion RBC recovery in patients. © 2016 AABB.

  18. The Crossmatch/Issue Ratio:  Use of a Novel Quality Indicator and Results of an International Survey on RBC Crossmatching and Issuing Practices

    DEFF Research Database (Denmark)

    Yazer, Mark H; Alcantara, Ramir; Beizai, Pouneh

    2016-01-01

    OBJECTIVES: To understand the worldwide scope of RBC crossmatching and issuing practices and measure efficiency using a novel quality indicator, the crossmatch/issue (C/I) ratio. METHODS: An electronic survey was disseminated to hospital transfusion services collecting details about RBC...... crossmatching and issuing practices. Respondents were asked to enumerate the number of RBCs crossmatched and issued at their institutions during the 2014 calendar year to calculate the C/I ratio. RESULTS: Fifty-two survey responses were received, mostly from North American transfusion services (28/52, 54......%). The electronic crossmatch was the most common technique (n = 29), and most respondents performed the crossmatch at the time that an order for RBCs was received in the transfusion service (even if an order to issue the RBCs was not received). Data to calculate the C/I ratio were supplied by 22 respondents...

  19. A Variable Stiffness Analysis Model for Large Complex Thin-Walled Guide Rail

    Directory of Open Access Journals (Sweden)

    Wang Xiaolong

    2016-01-01

    Full Text Available Large complex thin-walled guide rail has complicated structure and no uniform low rigidity. The traditional cutting simulations are time consuming due to huge computation especially in large workpiece. To solve these problems, a more efficient variable stiffness analysis model has been propose, which can obtain quantitative stiffness value of the machining surface. Applying simulate cutting force in sampling points using finite element analysis software ABAQUS, the single direction variable stiffness rule can be obtained. The variable stiffness matrix has been propose by analyzing multi-directions coupling variable stiffness rule. Combining with the three direction cutting force value, the reasonability of existing processing parameters can be verified and the optimized cutting parameters can be designed.

  20. Arterial stiffness in normotensive and hypertensive subjects: Frequency in community pharmacies.

    Science.gov (United States)

    Rodilla Sala, Enrique; Adell Alegre, Manuel; Giner Galvañ, Vicente; Perseguer Torregrosa, Zeneida; Pascual Izuel, Jose Maria; Climent Catalá, María Teresa

    2017-12-07

    Arterial stiffness (AS) is a well-recognized target organ lesion. This study aims to determine: 1) the frequency of AS in community pharmacies; 2) if stiffened subjects identified by brachial oscillometry have more CV risk factors than normal subjects, and 3) the dependence of stiffness on using either age-adjusted values or a fixed threshold. Observational, cross-sectional study in 32 community pharmacies of the Valencia Community, between November/2015 and April/2016. Stiffness was as pulse wave velocity (PWV) measured with a semi-automatic, validated device (Mobil-O-Graph ® , IEM), followed by a 10-item questionnaire. Mean age of the 1,427 consecutive recruited patients was 56.6 years. Overall proportion of patients with AS was 17.4% with age-adjusted PWV (9.4% in normotensives, 28.3% in hypertensives). Multivariate logistic regression showed independent association of stiffness in normotensives with male gender, obesity, higher pulse pressure and heart rate, in hypertensives, with higher pulse pressure and lower age. AS was globally found in 20.5% of subjects, defining stiffness by PWV>10m/s (6.2% in normotensives, 40.2% in hypertensives). It was associated with higher age and pulse pressure in both groups. Concordance in classifying stiffness was 74.6%. Frequency of AS varied between 17.4-20.5%. Age-adjusted stiffness is associated in normotensives with male gender, pulse pressure, obesity and heart rate, in hypertensives with pulse pressure and inversely to age. Stiffness by 10m/s is determined by higher pulse pressure and higher age. Both definitions of PWV are not interchangeable. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  1. Experimental study on vertical static stiffnesses of polycal wire rope isolators

    Science.gov (United States)

    Balaji, P. S.; Moussa, Leblouba; Khandoker, Noman; Yuk Shyh, Ting; Rahman, M. E.; Hieng Ho, Lau

    2017-07-01

    Wire rope isolator is one of the most effective isolation system that can be used to attenuate the vibration disturbances and shocks during the operation of machineries. This paper presents the results of investigation on static elastic stiffnesses (both in tension and in compression) of Polycal Wire Rope Isolator (PWRI) under quasi-static monotonic loading conditions. It also studied effect of variations in height and width of PWRI on its static stiffnesses. Suitable experimental setup was designed and manufactured to meet the test conditions. The results show that their elastic stiffnesses for both tension and compression loading conditions are highly influenced by their geometric dimensions. It is found that their compressive stiffness reduced by 55% for an increment of 20% in their height to width ratio. Therefore, the stiffness of PWRI can be fine-tuned by controlling their dimensions according to the requirements of the application.

  2. A Solvent-Free Surface Suspension Melt Technique for Making Biodegradable PCL Membrane Scaffolds for Tissue Engineering Applications

    Directory of Open Access Journals (Sweden)

    Ratima Suntornnond

    2016-03-01

    Full Text Available In tissue engineering, there is limited availability of a simple, fast and solvent-free process for fabricating micro-porous thin membrane scaffolds. This paper presents the first report of a novel surface suspension melt technique to fabricate a micro-porous thin membrane scaffolds without using any organic solvent. Briefly, a layer of polycaprolactone (PCL particles is directly spread on top of water in the form of a suspension. After that, with the use of heat, the powder layer is transformed into a melted layer, and following cooling, a thin membrane is obtained. Two different sizes of PCL powder particles (100 µm and 500 µm are used. Results show that membranes made from 100 µm powders have lower thickness, smaller pore size, smoother surface, higher value of stiffness but lower ultimate tensile load compared to membranes made from 500 µm powder. C2C12 cell culture results indicate that the membrane supports cell growth and differentiation. Thus, this novel membrane generation method holds great promise for tissue engineering.

  3. A METHOD OF DETERMINING THE COORDINATES OF THE STIFFNESS CENTER AND THE STIFFNESS PRINCIPAL AXIS OF THE VIBRATING SYSTEM WITH DAMPING

    Directory of Open Access Journals (Sweden)

    Dang Xuan Truong

    2014-12-01

    Full Text Available The report presents a methodology to determine the directions of the stiffness principal axis (in this case subject to the linear displacement and forced rotation angle of a solid object interact with the surrounding environment by resilient bearing supports. The results also show that determining the coordinates of the stiffness center in the vibrating system with damping factors is necessary in our research.

  4. Acute changes in arterial stiffness following exercise in people with metabolic syndrome.

    Science.gov (United States)

    Radhakrishnan, Jeyasundar; Swaminathan, Narasimman; Pereira, Natasha M; Henderson, Keiran; Brodie, David A

    This study aims to examine the changes in arterial stiffness immediately following sub-maximal exercise in people with metabolic syndrome. Ninety-four adult participants (19-80 years) with metabolic syndrome gave written consent and were measured for arterial stiffness using a SphygmoCor (SCOR-PVx, Version 8.0, Atcor Medical Private Ltd, USA) immediately before and within 5-10min after an incremental shuttle walk test. The arterial stiffness measures used were pulse wave velocity (PWV), aortic pulse pressure (PP), augmentation pressure, augmentation index (AI), subendocardial viability ratio (SEVR) and ejection duration (ED). There was a significant increase (pexercise. Exercise capacity had a strong inverse correlation with arterial stiffness and age (pExercise capacity is inversely related to arterial stiffness and age in people with metabolic syndrome. Exercise induced changes in arterial stiffness measured using pulse wave analysis is an important tool that provides further evidence in studying cardiovascular risk in metabolic syndrome. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  5. Spatially varying small-strain stiffness in soils subjected to K0 loading

    KAUST Repository

    Kim, Hyun-Ki; Santamarina, Carlos

    2017-01-01

    Grain-scale characteristics and formation history determine spatial variability in granular masses. We investigate the effect of spatially varying stiffness on the load-deformation response under zero-lateral strain conditions using numerical simulations of correlated random fields, where the granular medium is represented by a non-linear stress-dependent meso-scale model. Results show that stiffness heterogeneity results in higher global compressibility as compared to the homogeneous medium with the same arithmetic mean stiffness. Furthermore, the non-homogeneous stress field that develops inside the granular mass is characterized by focused load transfer along columnar regions, higher stress anisotropy and lower horizontal-to-vertical stress ratio K0 than in a granular medium of homogenous stiffness. As the applied stress increases, the inherent stress-dependent response of the granular material leads to a more homogenous stress field. While greater variance in stiffness causes lower global stiffness, a longer correlation length results in greater variance in global mechanical response among multiple realizations.

  6. Spatially varying small-strain stiffness in soils subjected to K0 loading

    KAUST Repository

    Kim, Hyun-Ki

    2017-08-08

    Grain-scale characteristics and formation history determine spatial variability in granular masses. We investigate the effect of spatially varying stiffness on the load-deformation response under zero-lateral strain conditions using numerical simulations of correlated random fields, where the granular medium is represented by a non-linear stress-dependent meso-scale model. Results show that stiffness heterogeneity results in higher global compressibility as compared to the homogeneous medium with the same arithmetic mean stiffness. Furthermore, the non-homogeneous stress field that develops inside the granular mass is characterized by focused load transfer along columnar regions, higher stress anisotropy and lower horizontal-to-vertical stress ratio K0 than in a granular medium of homogenous stiffness. As the applied stress increases, the inherent stress-dependent response of the granular material leads to a more homogenous stress field. While greater variance in stiffness causes lower global stiffness, a longer correlation length results in greater variance in global mechanical response among multiple realizations.

  7. Parametric instability of spinning elastic rings excited by fluctuating space-fixed stiffnesses

    Science.gov (United States)

    Liu, Chunguang; Cooley, Christopher G.; Parker, Robert G.

    2017-07-01

    This study investigates the vibration of rotating elastic rings that are dynamically excited by an arbitrary number of space-fixed discrete stiffnesses with periodically fluctuating stiffnesses. The rotating, elastic ring is modeled using thin-ring theory with radial and tangential deformations. Primary and combination instability regions are determined in closed-form using the method of multiple scales. The ratio of peak-to-peak fluctuation to average discrete stiffness is used as the perturbation parameter, so the resulting perturbation analysis is not limited to small mean values of discrete stiffnesses. The natural frequencies and vibration modes are determined by discretizing the governing equations using Galerkin's method. Results are demonstrated for compliant gear applications. The perturbation results are validated by direct numerical integration of the equations of motion and Floquet theory. The bandwidths of the instability regions correlate with the fractional strain energy stored in the discrete stiffnesses. For rings with multiple discrete stiffnesses, the phase differences between them can eliminate large amplitude response under certain conditions.

  8. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  9. Mixed, Nonsplit, Extended Stability, Stiff Integration of Reaction Diffusion Equations

    KAUST Repository

    Alzahrani, Hasnaa H.

    2016-01-01

    A tailored integration scheme is developed to treat stiff reaction-diffusion prob- lems. The construction adapts a stiff solver, namely VODE, to treat reaction im- plicitly together with explicit treatment of diffusion. The second-order Runge

  10. Increase in Leg Stiffness Reduces Joint Work During Backpack Carriage Running at Slow Velocities.

    Science.gov (United States)

    Liew, Bernard; Netto, Kevin; Morris, Susan

    2017-10-01

    Optimal tuning of leg stiffness has been associated with better running economy. Running with a load is energetically expensive, which could have a significant impact on athletic performance where backpack carriage is involved. The purpose of this study was to investigate the impact of load magnitude and velocity on leg stiffness. We also explored the relationship between leg stiffness and running joint work. Thirty-one healthy participants ran overground at 3 velocities (3.0, 4.0, 5.0 m·s -1 ), whilst carrying 3 load magnitudes (0%, 10%, 20% weight). Leg stiffness was derived using the direct kinetic-kinematic method. Joint work data was previously reported in a separate study. Linear models were used to establish relationships between leg stiffness and load magnitude, velocity, and joint work. Our results found that leg stiffness did not increase with load magnitude. Increased leg stiffness was associated with reduced total joint work at 3.0 m·s -1 , but not at faster velocities. The association between leg stiffness and joint work at slower velocities could be due to an optimal covariation between skeletal and muscular components of leg stiffness, and limb attack angle. When running at a relatively comfortable velocity, greater leg stiffness may reflect a more energy efficient running pattern.

  11. Tailoring the mechanical properties by molecular integration of flexible and stiff polymer networks.

    Science.gov (United States)

    Wan, Haixiao; Shen, Jianxiang; Gao, Naishen; Liu, Jun; Gao, Yangyang; Zhang, Liqun

    2018-03-28

    Designing a multiple-network structure at the molecular level to tailor the mechanical properties of polymeric materials is of great scientific and technological importance. Through the coarse-grained molecular dynamics simulation, we successfully construct an interpenetrating polymer network (IPN) composed of a flexible polymer network and a stiff polymer network. First, we find that there is an optimal chain stiffness for a single network (SN) to achieve the best stress-strain behavior. Then we turn to study the mechanical behaviors of IPNs. The result shows that the stress-strain behaviors of the IPNs appreciably exceed the sum of that of the corresponding single flexible and stiff network, which highlights the advantage of the IPN structure. By systematically varying the stiffness of the stiff polymer network of the IPNs, optimal stiffness also exists to achieve the best performance. We attribute this to a much larger contribution of the non-bonded interaction energy. Last, the effect of the component concentration ratio is probed. With the increase of the concentration of the flexible network, the stress-strain behavior of the IPNs is gradually enhanced, while an optimized concentration (around 60% molar ration) of the stiff network occurs, which could result from the dominant role of the enthalpy rather than the entropy. In general, our work is expected to provide some guidelines to better tailor the mechanical properties of the IPNs made of a flexible network and a stiff network, by manipulating the stiffness of the stiff polymer network and the component concentration ratio.

  12. Triceps-surae musculotendinous stiffness: relative differences between obese and non-obese postmenopausal women.

    Science.gov (United States)

    Faria, Aurélio; Gabriel, Ronaldo; Abrantes, João; Brás, Rui; Moreira, Helena

    2009-12-01

    There is a lack of research into the relationship between obesity and muscle-tendon unit stiffness in postmenopausal women. Muscle-tendon unit stiffness appears to affect human motion performance and excessive and insufficient stiffness can increase the risk of bone and soft tissue injuries, respectively. The aim of this study was to investigate the relationship between muscle-tendon unit stiffness and obesity in postmenopausal women. 105 postmenopausal women (58 [SD 5.5] years) participated. Four groups (normal weight, pre-obese, obesity class I and obesity class II) were defined according World Health Organization classification of body mass index. The ankle muscle-tendon unit stiffness was assessed in vivo with a free oscillation technique using a load of 30% of maximal voluntary isometric contraction. ANOVA shows significant difference in muscle-tendon unit stiffness among the groups defined (Pnormal weight-pre-obese; normal weight-obesity class I and normal weight-obesity class II. The normal weight group had stiffness of 15789 (SD 2969) N/m, pre-obese of 19971 (SD 3678) N/m, obesity class I of 21435 (SD 4295) N/m, and obesity class II of 23497 (SD 1776) N/m. Obese subjects may have increased muscle-tendon unit stiffness because of fat infiltration in leg skeletal muscles, range of motion restrictions and stability/posture reasons and might be more predisposed to develop musculoskeletal injuries. Normal weight group had identical stiffness values to those reported in studies where subjects were not yet menopausal, suggesting that stiffness might not be influenced by menopause.

  13. Graphene oxide improves the biocompatibility of collagen membranes in an in vitro model of human primary gingival fibroblasts.

    Science.gov (United States)

    De Marco, Patrizia; Zara, Susi; De Colli, Marianna; Radunovic, Milena; Lazović, Vladimir; Ettorre, Valeria; Di Crescenzo, Antonello; Piattelli, Adriano; Cataldi, Amelia; Fontana, Antonella

    2017-09-13

    Commercial collagen membranes are used in oral surgical procedures as scaffolds for bone deposition in guided bone regeneration. Here, we have enriched them with graphene oxide (GO) via a simple non-covalent functionalization, exploiting the capacity of oxygenated carbon functional moieties of GO to interact through hydrogen bonding with collagen. In the present paper, the GO-coated membranes have been characterized in terms of stability, nano-roughness, biocompatibility and induction of inflammatory response in human primary gingival fibroblast cells. The obtained coated membranes are demonstrated not to leak GO in the bulk solution, and to change some features of the membrane, such as stiffness and adhesion between the membrane and the atomic force microscopy (AFM) tip. Moreover, the presence of GO increases the roughness and the total surface exposed to the cells, as demonstrated by AFM analyses. The obtained material is biocompatible, and does not induce inflammation in the tested cells.

  14. Diffusion properties of band 3 in human erythrocytes

    Science.gov (United States)

    Spector, Jeffrey O.

    The plasma membrane of the human erythrocyte (RBC) is a six fold symmetric network held together at various pinning points by several multi-protein complexes. This unique architecture is what gives the RBC its remarkable material properties and any disruptions to the network can have severe consequences for the cell. Band 3 is a major transmembrane protein that plays the role of linking the fluid lipid bilayer to the cytoskeletal network. To interrogate the structural integrity of the RBC membrane we have tracked individual band 3 molecules in RBCs displaying a variety of pathologies that are all a consequence of membrane or network related defects. These diseases are spherocytosis, elliptocytosis, and pyropokilocytosis. We have also investigated the protein related diseases sickle cell, and south east asian ovalocytosis. To assess the impact that the network has on the dynamic organization of the cell we have also studied the mobility of band 3 in RBC progenitor cells. Individual band 3 molecules were imaged at 120 frames/second and their diffusion coefficients and compartment sizes recorded. The distributions of the compartment sizes combined with the information about the short and long time diffusion of band 3 has given us insight into the architecture of the membrane in normal and diseased cells. The observation that different membrane pathologies can be distinguished, even to the point of different molecular origins of the same disease, implies that the mobility of transmembrane proteins may be a useful tool for characterizing the "health" of the membrane.

  15. Betel nut chewing associated with increased risk of arterial stiffness.

    Science.gov (United States)

    Wei, Yu-Ting; Chou, Yu-Tsung; Yang, Yi-Ching; Chou, Chieh-Ying; Lu, Feng-Hwa; Chang, Chih-Jen; Wu, Jin-Shang

    2017-11-01

    Betel nut chewing is associated with certain cardiovascular outcomes. Subclinical atherosclerosis may be one link between betel nut chewing and cardiovascular risk. Few studies have examined the association between chewing betel nut and arterial stiffness. The aim of this study was thus to determine the relationship between betel nut chewing and arterial stiffness in a Taiwanese population. We enrolled 7540 eligible subjects in National Cheng Kung University Hospital from October 2006 to August 2009. The exclusion criteria included history of cerebrovascular events, coronary artery disease, and taking lipid-lowering drugs, antihypertensives, and hypoglycemic agents. Increased arterial stiffness was defined as brachial-ankle pulse wave velocity (baPWV) ≥1400cm/s. According to their habit of betel nut use, the subjects were categorized into non-, ex-, and current chewers. The prevalence of increased arterial stiffness was 32.7, 43.3, and 43.2% in non-, ex- and current chewers, respectively (p=0.011). Multiple logistic regression analysis revealed that ex-chewers (odds ratio [OR] 1.69, 95% confidence interval (CI)=1.08-2.65) and current chewers (OR 2.29, 95% CI=1.05-4.99) had elevated risks of increased arterial stiffness after adjustment for co-variables. Both ex- and current betel nut chewing were associated with a higher risk of increased arterial stiffness. Stopping betel nut chewing may thus potentially be beneficial to reduce cardiovascular risk, based on the principals of preventive medicine. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Sex Differences in Limb and Joint Stiffness in Recreational Runners

    Directory of Open Access Journals (Sweden)

    Sinclair Jonathan

    2015-09-01

    Full Text Available Purpose. Female runners are known to be at greater risk from chronic running injuries than age-matched males, although the exact mechanisms are often poorly understood. The aim of the current investigation was to determine if female recreational runners exhibit distinct limb and joint stiffness characteristics in relation to their male counterparts. Methods. Fourteen male and fourteen female runners ran over a force platform at 4.0 m · s-1. Lower limb kinematics were collected using an eight-camera optoelectric motion capture system operating at 250 Hz. Measures of limb and joint stiffness were calculated as a function of limb length and joint moments divided by the extent of limb and joint excursion. All stiffness and joint moment parameters were normalized to body mass. Sex differences in normalized limb and knee and ankle joint stiffness were examined statistically using independent samples t tests. Results. The results indicate that normalized limb (male = 0.18 ± 0.07, female = 0.37 ± 0.10 kN · kg · m-1 and knee stiffness (male = 5.59 ± 2.02, female = 7.34 ± 1.78 Nm · kg · rad-1 were significantly greater in female runners. Conclusions. On the basis that normalized knee and limb stiffness were shown to be significantly greater in female runners, the findings from the current investigation may provide further insight into the aetiology of the distinct injury patterns observed between sexes.

  17. Stiff-Person Syndrome and Graves’ Disease

    Directory of Open Access Journals (Sweden)

    Lais Moreira Medeiros MD

    2016-12-01

    Full Text Available A 9-year-old female child presented with a history of falls, weight loss, diffuse leg pain, and progressive gait disorder, following 1 previous event described as a tonic–clonic seizure. She had increased thyroid volume, brisk symmetric reflexes, abnormal gait, and painful spasms of the paraspinal musculature. Thyroid function tests indicated biochemical hyperthyroidism, and thyrotropin receptor antibodies were positive. Her electromyography showed continuous activation of normal motor units of the paraspinal and proximal lower extremity muscles. The patient had a diagnosis of Graves’ disease with associated stiff-person syndrome, with elevated anti–glutamic acid decarboxylase antibody levels. After intravenous immunoglobulin therapy, her ambulation was substantially improved and the symptoms of stiff-person syndrome decreased dramatically.

  18. An L-stable method for solving stiff hydrodynamics

    Science.gov (United States)

    Li, Shengtai

    2017-07-01

    We develop a new method for simulating the coupled dynamics of gas and multi-species dust grains. The dust grains are treated as pressure-less fluids and their coupling with gas is through stiff drag terms. If an explicit method is used, the numerical time step is subject to the stopping time of the dust particles, which can become extremely small for small grains. The previous semi-implicit method [1] uses second-order trapezoidal rule (TR) on the stiff drag terms and it works only for moderately small size of the dust particles. This is because TR method is only A-stable not L-stable. In this work, we use TR-BDF2 method [2] for the stiff terms in the coupled hydrodynamic equations. The L-stability of TR-BDF2 proves essential in treating a number of dust species. The combination of TR-BDF2 method with the explicit discretization of other hydro terms can solve a wide variety of stiff hydrodynamics equations accurately and efficiently. We have implemented our method in our LA-COMPASS (Los Alamos Computational Astrophysics Suite) package. We have applied the code to simulate some dusty proto-planetary disks and obtained very good match with astronomical observations.

  19. Hormones and arterial stiffness in patients with chronic kidney disease.

    Science.gov (United States)

    Gungor, Ozkan; Kircelli, Fatih; Voroneanu, Luminita; Covic, Adrian; Ok, Ercan

    2013-01-01

    Cardiovascular disease constitutes the major cause of mortality in patients with chronic kidney disease. Arterial stiffness is an important contributor to the occurrence and progression of cardiovascular disease. Various risk factors, including altered hormone levels, have been suggested to be associated with arterial stiffness. Based on the background that chronic kidney disease predisposes individuals to a wide range of hormonal changes, we herein review the available data on the association between arterial stiffness and hormones in patients with chronic kidney disease and summarize the data for the general population.

  20. Cellular shear stiffness reflects progression of arsenic-induced transformation during G1

    DEFF Research Database (Denmark)

    Muñoz, Alexandra; Eldridge, Will J; Jakobsen, Nina Munkholt

    2017-01-01

    epithelial cells were exposed to sodium arsenite to initiate early stages of transformation. Exposed cells were cultured in soft agar to further transformation and select for clonal populations exhibiting anchorage independent growth. Shear stiffness of various cell populations in G1 was assessed using...... reduced stiffness relative to control clonal lines, which were cultured in soft agar but did not receive arsenic treatment. The relative standard deviation of the stiffness of Arsenic clones was reduced compared to control clones, as well as to the arsenic exposed cell population. Cell stiffness...

  1. Research on a novel high stiffness axial passive magnetic bearing for DGMSCMG

    International Nuclear Information System (INIS)

    Sun, Jinji; Wang, Chun'e; Le, Yun

    2016-01-01

    To increase the displacement stiffness and decrease power loss of double gimbals magnetically suspended control momentum gyro (DGMSCMG), this paper researches a new structure of axial passive magnetic bearing (APMB). Different from the existing APMB, the proposed APMB is composed of segmented permanent magnets and magnetic rings. The displacement stiffness and angular stiffness expressions are derived by equivalent magnetic circuit method and infinitesimal method based on the end magnetic flux. The relationships are analyzed between stiffness and structure parameters such as length of air gap, length of permanent magnet, height of permanent magnet and end length of magnetic ring. Besides, the axial displacement stiffness measurement method of the APMB is proposed, and it verified the correctness of proposed theoretical method. The DGMSCMG prototype is manufactured and the slow-down characteristic experiment is carried out, and the experimental result reflects the low power loss feature of the APMB. - Highlights: • A novel high stiffness axial passive magnetic bearing for DGMSCMG. • The proposed APMB is composed of segmented permanent magnets and magnetic rings. • The APMB is analyzed by EMCM and infinitesimal method based on the end magnetic flux. • The axial displacement stiffness measurement method of the APMB is proposed. • The DGMSCMG is manufactured and proved the correctness of theoretical analysis.

  2. Theoretical and experimental studies on in-plane stiffness of integrated container structure

    Directory of Open Access Journals (Sweden)

    Xiaoxiong Zha

    2016-03-01

    Full Text Available This article presents analytical, numerical, and experimental studies on the in-plane stiffness of container buildings. First, based on diaphragm theory, parallel corrugated direction stiffness of corrugated sheet has been deduced, and based on energy method, shear modulus of two elastic principal directions of orthotropic plate has been deduced, and through stiffness conversion method, the stiffness relationship between parallel corrugated direction and vertical corrugated direction has been obtained. Combined with container frame, the container stiffness of loading end and non-loading end, as bottom side beam fixed, has been obtained. Second, through the software Abaqus, full-scale container model has been established. The loading–displacement curve of finite element model has been compared with theoretical analysis and has a good agreement. Third, through 20 and 40 ft container, corresponding experimental verification has been done, and by comparison of container stiffness, the theoretical analysis and finite element simulation have been verified. Finally, based on verified finite element model, parametric analysis of corrugated sheet size, corrugated sheeting cross section, elasticity modulus of top side beam, and every plate action for container stiffness have been given. Research result has made feasible in design and construction of container buildings and can provide some references to corresponding specification preparation.

  3. Evolution of RLSB, a nuclear-encoded S1 domain RNA binding protein associated with post-transcriptional regulation of plastid-encoded rbcL mRNA in vascular plants.

    Science.gov (United States)

    Yerramsetty, Pradeep; Stata, Matt; Siford, Rebecca; Sage, Tammy L; Sage, Rowan F; Wong, Gane Ka-Shu; Albert, Victor A; Berry, James O

    2016-06-29

    RLSB, an S-1 domain RNA binding protein of Arabidopsis, selectively binds rbcL mRNA and co-localizes with Ribulose-1,5-bisphosphate carboxylase/oxygenase (Rubisco) within chloroplasts of C3 and C4 plants. Previous studies using both Arabidopsis (C3) and maize (C4) suggest RLSB homologs are post-transcriptional regulators of plastid-encoded rbcL mRNA. While RLSB accumulates in all Arabidopsis leaf chlorenchyma cells, in C4 leaves RLSB-like proteins accumulate only within Rubisco-containing bundle sheath chloroplasts of Kranz-type species, and only within central compartment chloroplasts in the single cell C4 plant Bienertia. Our recent evidence implicates this mRNA binding protein as a primary determinant of rbcL expression, cellular localization/compartmentalization, and photosynthetic function in all multicellular green plants. This study addresses the hypothesis that RLSB is a highly conserved Rubisco regulatory factor that occurs in the chloroplasts all higher plants. Phylogenetic analysis has identified RLSB orthologs and paralogs in all major plant groups, from ancient liverworts to recent angiosperms. RLSB homologs were also identified in algae of the division Charophyta, a lineage closely related to land plants. RLSB-like sequences were not identified in any other algae, suggesting that it may be specific to the evolutionary line leading to land plants. The RLSB family occurs in single copy across most angiosperms, although a few species with two copies were identified, seemingly randomly distributed throughout the various taxa, although perhaps correlating in some cases with known ancient whole genome duplications. Monocots of the order Poales (Poaceae and Cyperaceae) were found to contain two copies, designated here as RLSB-a and RLSB-b, with only RLSB-a implicated in the regulation of rbcL across the maize developmental gradient. Analysis of microsynteny in angiosperms revealed high levels of conservation across eudicot species and for both paralogs in

  4. The influence of irradiation potential on the degree of conversion and mechanical properties of two bulk-fill flowable RBC base materials.

    Science.gov (United States)

    Finan, Leah; Palin, William M; Moskwa, Natalia; McGinley, Emma Louise; Fleming, Garry J P

    2013-08-01

    To assess the depth of cure claims of two bulk-fill flowable RBC bases (SDR and x-tra base) using Fourier transform infrared (FTIR) spectroscopy, biaxial flexure strength (BFS), and Vickers hardness number (VHN) for specimen depths of 8mm (in 1mm increments). The degree of conversion (DC) was measured by monitoring the peak height (6164cm(-1)) of specimens (11.0±0.1mm diameter, 1.0±0.1mm thickness) during light irradiation for 20s using a quartz tungsten halogen light curing unit at 650±26mW/cm(2). DC was measured up to 120s post irradiation and repeated (n=3) for irradiation depths up to 8mm (in 1mm increments). Further series (n=20) of eight discs were prepared, stacked, light irradiated and numbered from one to eight (distance from the LCU). The specimens were stored at 37±1°C for 24h and BFS tested with the fracture fragments used to determine the VHN for each specimen. X-tra base can be irradiated to 8mm without a change in DC, something the SDR material cannot claim. However, the DC results confirm both bulk-fill flowable RBC bases have a depth of cure in excess of 4mm. One-way ANOVAs of BFS and VHN data showed significant differences between irradiation depths for x-tra base and SDR with increasing irradiation depth (4mm) resulting in significant reductions in mean BFS and VHN. The claims that the bulk-fill flowable RBC bases have a depth of cure in excess of 4mm can be confirmed but the differing chemistry of the resin formulations and filler characteristics contribute to significant differences in DC, BFS and VHN data between the two materials tested. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Human arm stiffness and equilibrium-point trajectory during multi-joint movement.

    Science.gov (United States)

    Gomi, H; Kawato, M

    1997-03-01

    By using a newly designed high-performance manipulandum and a new estimation algorithm, we measured human multi-joint arm stiffness parameters during multi-joint point-to-point movements on a horizontal plane. This manipulandum allows us to apply a sufficient perturbation to subject's arm within a brief period during movement. Arm stiffness parameters were reliably estimated using a new algorithm, in which all unknown structural parameters could be estimated independent of arm posture (i.e., constant values under any arm posture). Arm stiffness during transverse movement was considerably greater than that during corresponding posture, but not during a longitudinal movement. Although the ratios of elbow, shoulder, and double-joint stiffness were varied in time, the orientation of stiffness ellipses during the movement did not change much. Equilibrium-point trajectories that were predicted from measured stiffness parameters and actual trajectories were slightly sinusoidally curved in Cartesian space and their velocity profiles were quite different from the velocity profiles of actual hand trajectories. This result contradicts the hypothesis that the brain does not take the dynamics into account in movement control depending on the neuromuscular servo mechanism; rather, it implies that the brain needs to acquire some internal models of controlled objects.

  6. Sabot Front Borerider Stiffness vs. Dispersion: Finding the Knee in the Curve

    Directory of Open Access Journals (Sweden)

    Alan F. Hathaway

    2001-01-01

    Full Text Available In the design of armor piercing, fin-stabilized, discarding sabot projectiles, the radial stiffness of the sabot front borerider has a significant impact on the projectile's dispersion and is, therefore, an important design consideration. Whether designing a new projectile or trying to improve an existing design, projectile designers can achieve front borerider stiffness without understanding its affect on dispersion characteristics. There is a knee in the stiffness vs. dispersion curve at which a change in the sabot front borerider stiffness will have a significant impact on dispersion or no impact at all depending on whether the stiffness is increased or decreased. The subject of this paper is an analytical approach to quantitatively determine the knee in the curve. Results from using this approach on the M865 APFSDS projectile are also presented.

  7. Validation of the omega-3 fatty acid intake measured by a web-based food frequency questionnaire against omega-3 fatty acids in red blood cells in men with prostate cancer.

    Science.gov (United States)

    Allaire, J; Moreel, X; Labonté, M-È; Léger, C; Caron, A; Julien, P; Lamarche, B; Fradet, V

    2015-09-01

    The objective of this study was to evaluate the ability of a web-based self-administered food frequency questionnaire (web-FFQ) to assess the omega-3 (ω-3) fatty acids (FAs) intake of men affected with prostate cancer (PCa) against a biomarker. The study presented herein is a sub-study from a phase II clinical trial. Enrolled patients afflicted with PCa were included in the sub-study analysis if the FA profiles from the red blood cell (RBC) membranes and FA intakes at baseline were both determined at the time of the data analysis (n=60). Spearman's correlation coefficients were calculated to estimate the correlations between FA intakes and their proportions in the RBC membranes. Intakes of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) were highly correlated with their respective proportions in the RBC membranes (both rs=0.593, Pstudies carried out in men with PCa.

  8. Knee joint stiffness in individuals with and without knee osteoarthritis: a preliminary study.

    Science.gov (United States)

    Oatis, Carol A; Wolff, Edward F; Lennon, Sandra K

    2006-12-01

    Descriptive, case-matched comparison. To compare the knee joint stiffness and damping coefficients of individuals with knee osteoarthritis (KOA) to those of age- and gender-matched individuals without KOA. A secondary purpose was to investigate relationships between these coefficients and complaints of stiffness in individuals with KOA. KOA is a leading cause of disability, and stiffness is a common complaint in individuals with KOA. Yet the most common method of assessing knee joint stiffness is through a self-report questionnaire. Stiffness and damping coefficients at the knee were calculated in 10 volunteers (mean age +/- SD, 64.1+/-15.5 years) with KOA and compared to coefficients from age-and gender-matched individuals without KOA, collected in a previous study (mean age +/- SD, 62.1+/-13.9 years). Stiffness and damping coefficients were calculated from the angular motion of the knee during a relaxed oscillation. Spearman correlation coefficients were calculated between stiffness and damping coefficients and WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) scores for subjects with KOA. Independent 2-tailed t tests revealed significantly larger damping coefficients (P = .035) among those with KOA (95% CI, 0.10-2.32 Nm s/rad). Spearman rank correlations revealed a significant positive relationship (r = .85, P = .003) between the damping coefficient and the stiffness subscore of the WOMAC. This study offers preliminary data demonstrating the feasibility of measuring stiffness and damping coefficients in individuals with KOA. Additionally, the damping coefficient is increased in people with KOA when compared to age- and gender-matched individuals without KOA. The damping coefficient appears to be associated with the complaints of stiffness reported by the WOMAC.

  9. Evaluation of stiffness feedback for hard nodule identification on a phantom silicone model.

    Science.gov (United States)

    Li, Min; Konstantinova, Jelizaveta; Xu, Guanghua; He, Bo; Aminzadeh, Vahid; Xie, Jun; Wurdemann, Helge; Althoefer, Kaspar

    2017-01-01

    Haptic information in robotic surgery can significantly improve clinical outcomes and help detect hard soft-tissue inclusions that indicate potential abnormalities. Visual representation of tissue stiffness information is a cost-effective technique. Meanwhile, direct force feedback, although considerably more expensive than visual representation, is an intuitive method of conveying information regarding tissue stiffness to surgeons. In this study, real-time visual stiffness feedback by sliding indentation palpation is proposed, validated, and compared with force feedback involving human subjects. In an experimental tele-manipulation environment, a dynamically updated color map depicting the stiffness of probed soft tissue is presented via a graphical interface. The force feedback is provided, aided by a master haptic device. The haptic device uses data acquired from an F/T sensor attached to the end-effector of a tele-manipulated robot. Hard nodule detection performance is evaluated for 2 modes (force feedback and visual stiffness feedback) of stiffness feedback on an artificial organ containing buried stiff nodules. From this artificial organ, a virtual-environment tissue model is generated based on sliding indentation measurements. Employing this virtual-environment tissue model, we compare the performance of human participants in distinguishing differently sized hard nodules by force feedback and visual stiffness feedback. Results indicate that the proposed distributed visual representation of tissue stiffness can be used effectively for hard nodule identification. The representation can also be used as a sufficient substitute for force feedback in tissue palpation.

  10. Evaluation of stiffness feedback for hard nodule identification on a phantom silicone model.

    Directory of Open Access Journals (Sweden)

    Min Li

    Full Text Available Haptic information in robotic surgery can significantly improve clinical outcomes and help detect hard soft-tissue inclusions that indicate potential abnormalities. Visual representation of tissue stiffness information is a cost-effective technique. Meanwhile, direct force feedback, although considerably more expensive than visual representation, is an intuitive method of conveying information regarding tissue stiffness to surgeons. In this study, real-time visual stiffness feedback by sliding indentation palpation is proposed, validated, and compared with force feedback involving human subjects. In an experimental tele-manipulation environment, a dynamically updated color map depicting the stiffness of probed soft tissue is presented via a graphical interface. The force feedback is provided, aided by a master haptic device. The haptic device uses data acquired from an F/T sensor attached to the end-effector of a tele-manipulated robot. Hard nodule detection performance is evaluated for 2 modes (force feedback and visual stiffness feedback of stiffness feedback on an artificial organ containing buried stiff nodules. From this artificial organ, a virtual-environment tissue model is generated based on sliding indentation measurements. Employing this virtual-environment tissue model, we compare the performance of human participants in distinguishing differently sized hard nodules by force feedback and visual stiffness feedback. Results indicate that the proposed distributed visual representation of tissue stiffness can be used effectively for hard nodule identification. The representation can also be used as a sufficient substitute for force feedback in tissue palpation.

  11. Cryotherapy induces an increase in muscle stiffness.

    Science.gov (United States)

    Point, M; Guilhem, G; Hug, F; Nordez, A; Frey, A; Lacourpaille, L

    2018-01-01

    Although cold application (ie, cryotherapy) may be useful to treat sports injuries and to prevent muscle damage, it is unclear whether it has adverse effects on muscle mechanical properties. This study aimed to determine the effect of air-pulsed cryotherapy on muscle stiffness estimated using ultrasound shear wave elastography. Myoelectrical activity, ankle passive torque, shear modulus (an index of stiffness), and muscle temperature of the gastrocnemius medialis were measured before, during an air-pulsed cryotherapy (-30°C) treatment of four sets of 4 minutes with 1-minute recovery in between and during a 40 minutes postcryotherapy period. Muscle temperature significantly decreased after the second set of treatment (10 minutes: 32.3±2.5°C; Pcryotherapy induces an increase in muscle stiffness. This acute change in muscle mechanical properties may lower the amount of stretch that the muscle tissue is able to sustain without subsequent injury. This should be considered when using cryotherapy in athletic practice. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. The relationship between passive stiffness and evoked twitch properties: the influence of muscle CSA normalization

    International Nuclear Information System (INIS)

    Ryan, E D; Thompson, B J; Sobolewski, E J; Herda, T J; Costa, P B; Walter, A A; Cramer, J T

    2011-01-01

    Passive stiffness measurements are often used as a clinical tool to examine a muscle's passive lengthening characteristics. The purpose of this study was to examine the relationship between passive stiffness and evoked twitch properties prior to and following normalization of passive stiffness to muscle cross-sectional area (CSA). Ten healthy volunteers (mean ± SD age = 23 ± 3 year) performed passive range of motion, evoked twitch, and muscle CSA assessments of the plantar flexor muscles. Passive stiffness was determined from the slope of the final 5° of the angle–torque curve. Peak twitch torque (PTT) and rate of torque development (RTD) were determined via transcutaneous electrical stimulation, and muscle CSA was assessed using a peripheral quantitative computed tomography scanner. Pearson product moment correlation coefficients (r) were used to assess the relationships between passive stiffness and PTT and RTD and normalized passive stiffness (passive stiffness . muscle CSA −1 ) and PTT and RTD. Significant positive relationships were observed between passive stiffness and PTT (P = 0.003, r = 0.828) and RTD (P = 0.003, r = 0.825). There were no significant relationships between normalized passive stiffness and PTT (P = 0.290, r = 0.372) or RTD (P = 0.353, r = 0.329) demonstrating that stiffness did not account for a significant portion of the variance in twitch properties. Passive stiffness was largely influenced by the amount of muscle tissue in this study. Future studies that examine muscle stiffness and its relationship with performance measures, among different populations, and following various interventions may consider normalizing stiffness measurements to muscle CSA

  13. Stiffness Analysis and Comparison of 3-PPR Planar Parallel Manipulators with Actuation Compliance

    DEFF Research Database (Denmark)

    Wu, Guanglei; Bai, Shaoping; Kepler, Jørgen Asbøl

    2012-01-01

    In this paper, the stiffness of 3-PPR planar parallel manipulator (PPM) is analyzed with the consideration of nonlinear actuation compliance. The characteristics of the stiffness matrix pertaining to the planar parallel manipulators are analyzed and discussed. Graphic representation of the stiffn...... of the stiffness characteristics by means of translational and rotational stiffness mapping is developed. The developed method is illustrated with an unsymmetrical 3-PPR PPM, being compared with its structure-symmetrical counterpart....

  14. Explicit formulation of an anisotropic Allman/DKT 3-node thin triangular flat shell elements

    Science.gov (United States)

    Ertas, A.; Krafcik, J. T.; Ekwaro-Osire, S.

    A simple, explicit formulation of the stiffness matrix for an anisotropic, 3-node, thin triangular, flat shell element in global coordinates is presented. An Allman triangle is used for membrane stiffness. The membrane stiffness matrix is explicitly derived by applying an Allman transformation to a Felippa 6-node linear strain triangle (LST). Bending stiffness is incorporated by the use of a discrete Kirchhoff triangle (DKT) bending triangle. Stiffness terms resulting from anisotropic membrane-bending coupling are included by integrating, in area coordinates, membrane and bending strain-displacement matrices.

  15. Role of flexural stiffness of leukocyte microvilli in adhesion dynamics

    Science.gov (United States)

    Wu, Tai-Hsien; Qi, Dewei

    2018-03-01

    Previous work reported that microvillus deformation has an important influence on dynamics of cell adhesion. However, the existing studies were limited to the extensional deformation of microvilli and did not consider the effects of their bending deformation on cell adhesion. This Rapid Communication investigates the effects of flexural stiffness of microvilli on the rolling process related to adhesion of leukocytes by using a lattice-Boltzmann lattice-spring method (LLM) combined with adhesive dynamics (AD) simulations. The simulation results reveal that the flexural stiffness of microvilli and their bending deformation have a profound effect on rolling velocity and adhesive forces. As the flexural stiffness of the microvilli decreases, their bending angles increase, resulting in an increase in the number of receptor-ligand bonds and adhesive bonding force and a decrease in the rolling velocity of leukocytes. The effects of flexural stiffness on deformation and adhesion represent crucial factors involved in cell adhesion.

  16. Evaluation of arterial stiffness in nondiabetic chronic kidney disease patients

    Directory of Open Access Journals (Sweden)

    Bodanapu Mastanvalli

    2017-01-01

    Full Text Available Chronic kidney disease (CKD is a growing problem worldwide. Clinical and epidemiologic studies have shown that structural and functional changes that occur in major arteries are a major contributing factor to the high mortality in uremic patients. Recent studies have shown a stepwise increase of the carotid-femoral pulse wave velocity (cfPWV from CKD Stage 1 to Stage 5. We evaluated the cfPWV and augmentation index (AIx, as indirect markers of arterial stiffness in patients with nondiabetic CKD and compared the values with normal population; we also evaluated the relationship between various stages of CKD and arterial stiffness markers. This cross-sectional study was carried out in the Department of Nephrology for a duration of two years from January 15, 2012, to January 14, 2014. Fifty patients with nondiabetic CKD were studied along with 50 healthy volunteers who did not have CKD, who served as controls. Assessment of arterial stiffness (blood pressure, PWV, heart rate, aortic augmentation pressure, and AIx was performed using the PeriScope device. PWV positively correlated with systolic and diastolic blood pressure, mean aortic arterial pressure, serum creatinine, and serum uric acid and negatively correlated with estimated glomerular filtration rate. Arterial stiffness increased as CKD stage increased and was higher in nondiabetic CKD group than in the general population. Arterial stiffness progressed gradually from CKD Stage 2 to 5, and then abruptly, in dialysis patients. Measures to decrease the arterial stiffness and its influence on decreasing cardiovascular events need further evaluation.

  17. Dietary fat intake and red blood cell fatty acid composition of children and women from three different geographical areas in South Africa.

    Science.gov (United States)

    Ford, Rosalyn; Faber, Mieke; Kunneke, Ernesta; Smuts, Cornelius M

    2016-06-01

    Dietary fat intake, particularly the type of fat, is reflected in the red blood cell (RBC) fatty acid (FA) profile and is vital in growth, development and health maintenance. The FA profile (%wt/wt) of RBC membrane phospholipids (as determined by gas chromatography) and dietary intake (as determined by 24h recall) was assessed in 2-6y old South African children and their caregivers randomly selected from three communities, i.e. an urban Northern Cape community (urban-NC; n=104), an urban coastal Western Cape community (urban-WC; n=93) and a rural Limpopo Province community (rural-LP; n=102). Mean RBC FA values across groups were compared using ANOVA and Bonferroni post-hoc test while controlling for age and gender (children); median dietary intake values were compared using a Kruskal-Wallis test. Dietary intakes for total fat, saturated FAs and polyunsaturated FAs were higher in the two urban areas compared to the rural area. Total fat intake in rural-LP, and omega-3 FA dietary intake in all three areas were lower than the South African adopted guidelines. Dietary SFA intake in both urban areas was higher than recommended by South African guidelines; this was reflected in the RBC membrane FA profile. Rural-LP children had the lowest intake of omega-3 and omega-6 FAs yet presented with the highest RBC docosahexaenoic acid (DHA) profile and highest arachidonic acid percentage. Although differences observed in dietary fat intake between the two urban and the rural area were reflected in the RBC membrane total phospholipid FA profile, the lowest total fat and α-linolenic acid (ALA) intake by rural children that presented with the highest RBC DHA profile warrants further investigation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Vascular Stiffness and Increased Pulse Pressure in the Aging Cardiovascular System

    Directory of Open Access Journals (Sweden)

    Jochen Steppan

    2011-01-01

    Full Text Available Aging leads to a multitude of changes in the cardiovascular system, including systolic hypertension, increased central vascular stiffness, and increased pulse pressure. In this paper we will review the effects of age-associated increased vascular stiffness on systolic blood pressure, pulse pressure, augmentation index, and cardiac workload. Additionally we will describe pulse wave velocity as a method to measure vascular stiffness and review the impact of increased vascular stiffness as an index of vascular health and as a predictor of adverse cardiovascular outcomes. Furthermore, we will discuss the underlying mechanisms and how these may be modified in order to change the outcomes. A thorough understanding of these concepts is of paramount importance and has therapeutic implications for the increasingly elderly population.

  19. One-loop potential in the new string model with negative stiffness

    International Nuclear Information System (INIS)

    Kleinert, H.; Chervyakov, A.M.; Nesterenko, V.V.

    1996-01-01

    The color-electric flux tube between quarks has a finite thickness therefore also a finite curvature stiffness. Contrary to earlier rigid-string proposal by Polyakov and Kleinert and motivated by the properties of a magnetic flux tube in a type-II superconductor, we put forward the hypothesis that the stiffness is negative. We set up and study the properties of an idealized string model with such negative stiffness. In contrast to the rigid string, the propagator in the new model has no unphysical pole. One-loop calculations show that the model generates an interquark potential which does not contain the square root singularity even for moderate values of a negative stiffness. At large distances, the potential has usual linearly rising term with the universal Luescher correction

  20. MINIMUM BRACING STIFFNESS FOR MULTI-COLUMN SYSTEMS: THEORY

    OpenAIRE

    ARISTIZÁBAL-OCHOA, J. DARÍO

    2011-01-01

    A method that determines the minimum bracing stiffness required by a multi-column elastic system to achieve non-sway buckling conditions is proposed. Equations that evaluate the required minimum stiffness of the lateral and torsional bracings and the corresponding “braced" critical buckling load for each column of the story level are derived using the modified stability functions. The following effects are included: 1) the types of end connections (rigid, semirigid, and simple); 2) the bluepr...

  1. Online Identification and Verification of the Elastic Coupling Torsional Stiffness

    Directory of Open Access Journals (Sweden)

    Wanyou Li

    2016-01-01

    Full Text Available To analyze the torsional vibration of a diesel engine shaft, the torsional stiffness of the flexible coupling is a key kinetic parameter. Since the material properties of the elastic element of the coupling might change after a long-time operation due to the severe working environment or improper use and the variation of such properties will change dynamic feature of the coupling, it will cause a relative large calculation error of torsional vibration to the shaft system. Moreover, the torsional stiffness of the elastic coupling is difficult to be determined, and it is inappropriate to measure this parameter by disassembling the power unit while it is under normal operation. To solve these problems, this paper comes up with a method which combines the torsional vibration test with the calculation of the diesel shafting and uses the inherent characteristics of shaft torsional vibration to identify the dynamic stiffness of the elastic coupling without disassembling the unit. Analysis results show that it is reasonable and feasible to identify the elastic coupling dynamic torsional stiffness with this method and the identified stiffness is accurate. Besides, this method provides a convenient and practical approach to examine the dynamic behavior of the long running elastic coupling.

  2. COMPARISON OF CD46 EXPRESSION ON THE INNER ACROSOMAL MEMBRANE OF SPERMS FROM NORMOSPERMIC AND ASTHENOSPERMIC INDIVIDUALS

    Directory of Open Access Journals (Sweden)

    M NASR ESFAHANI

    2003-03-01

    Full Text Available Introduction: CD46 is a membrane cofactor protein (MCP of complement system wich is present on the membrane of all somatic cells except RBC. It is also present on the inner acrosmal membrane of human sperm. Thus, the aim of this study was to compare the expression of this prote, in on the inner acrosmal membrane of sperms from normospermic and asthenospermic individuals. Method: Semen from 6 normospermic and 17 asthenospermic individuals were examined for CD46 expression. After solublization of sperms in solublizing detergent, the solublized sperm membrane was separated from the rest of cell organelles by centrifugation. Solublized sperm membrane were divide to equal parts and SOS-PAGE gel was canied out in paired on the same gel for each sample. Western blot was carried out on half of the gel and then the nitrocellose papers were stained by a monocolonal Ab and HRP conjugate Ab. The other half were stained by silver stain for identification of MW. Results: After scoring the stained nitrocellose papen in each groups, no statistical significant difference was observed for C046 expression between the two groups. However, a significant Spearmen correlation was observed between CD46 expression and sperm motility (r=0.597, P=0.003. The MW of C046 was between 36 to 45 KD. with a mean of 42 KD. Discussion: This is the first report of a positive Spearmen correlation between sperm CD46 expression and sperm motility which suggest that there might be relation between CD46 expression and sperm motility.

  3. The effect of eccentric and concentric calf muscle training on Achilles tendon stiffness.

    Science.gov (United States)

    Morrissey, Dylan; Roskilly, Anna; Twycross-Lewis, Richard; Isinkaye, Tomide; Screen, Hazel; Woledge, Roger; Bader, Dan

    2011-03-01

    To compare in vivo effects of eccentric and concentric calf muscle training on Achilles tendon stiffness, in subjects without tendinopathy. Thirty-eight recreational athletes completed 6 weeks eccentric (6 males, 13 females, 21.6  ±  2.2 years) or concentric training (8 males, 11 females, 21.1  ±  2.0 years). Achilles tendon stiffness, tendon modulus and single-leg jump height were measured before and after intervention. Exercise adherence was recorded using a diary. All data are reported as mean  ±  SD. Groups were matched for height and weight but the eccentric training group were more active at baseline (P Tendon stiffness was higher in the eccentrically trained group at baseline compared to the concentrically trained group (20.9  ±  7.3 N/mm v 13.38  ±  4.66 N/mm; P = 0.001) and decreased significantly after eccentric training (to 17.2 ( ±  5.9) N/mm (P = 0.035)). There was no stiffness change in the concentric group (P = 0.405). Stiffness modulus showed similar changes to stiffness. An inverse correlation was found between initial, and subsequent, reduction in stiffness (r = -0.66). Jump height did not change and no correlation between stiffness change and adherence was observed in either group (r = 0.01). Six weeks of eccentric training can alter Achilles tendon stiffness while a matched concentric programme shows no similar effects. Studies in patients with Achilles tendinopathy are warranted.

  4. Hypertension, Diabetes Type II, and Their Association: Role of Arterial Stiffness.

    Science.gov (United States)

    Smulyan, Harold; Lieber, Ari; Safar, Michel E

    2016-01-01

    In patients with both hypertension and type II diabetes, the systolic blood pressure (SBP) increases linearly with age, while that of diastolic blood pressure (DBP) declines curvilinearly as early as age 45, all suggesting the development of increased arterial stiffness. Increased stiffness is an important, independent, and significant risk predictor in subjects with hypertension and diabetes. In patients with both diseases, stiffness assessed at the same mean arterial pressure (MAP) was significantly higher in diabetic patients. Arterial stiffness is related to age, heart rate (HR), and MAP, but in diabetic patients, it also related to diabetes duration and insulin treatment (IT). In the metabolic syndrome (MetSyn), diabetes also acts on the small arteries through capillary rarefaction to reduce the effective length of the arterial tree, increases the reflected pulse wave and thus the pulse pressure (PP). These studies indicate that diabetes and hypertension additively contribute to increased pulsatility and suggest that any means to reduce stiffness would be beneficial in these conditions. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Matrix Stiffness Corresponding to Strictured Bowel Induces a Fibrogenic Response in Human Colonic Fibroblasts

    Science.gov (United States)

    Johnson, Laura A.; Rodansky, Eva S.; Sauder, Kay L.; Horowitz, Jeffrey C.; Mih, Justin D.; Tschumperlin, Daniel J.; Higgins, Peter D.

    2013-01-01

    Background Crohn’s disease is characterized by repeated cycles of inflammation and mucosal healing which ultimately progress to intestinal fibrosis. This inexorable progression towards fibrosis suggests that fibrosis becomes inflammation-independent and auto-propagative. We hypothesized that matrix stiffness regulates this auto-propagation of intestinal fibrosis. Methods The stiffness of fresh ex vivo samples from normal human small intestine, Crohn’s disease strictures, and the unaffected margin were measured with a microelastometer. Normal human colonic fibroblasts were cultured on physiologically normal or pathologically stiff matrices corresponding to the physiological stiffness of normal or fibrotic bowel. Cellular response was assayed for changes in cell morphology, α-smooth muscle actin (αSMA) staining, and gene expression. Results Microelastometer measurements revealed a significant increase in colonic tissue stiffness between normal human colon and Crohn’s strictures as well as between the stricture and adjacent tissue margin. In Ccd-18co cells grown on stiff matrices corresponding to Crohn’s strictures, cellular proliferation increased. Pathologic stiffness induced a marked change in cell morphology and increased αSMA protein expression. Growth on a stiff matrix induced fibrogenic gene expression, decreased matrix metalloproteinase and pro-inflammatory gene expression, and was associated with nuclear localization of the transcriptional cofactor MRTF-A. Conclusions Matrix stiffness, representative of the pathological stiffness of Crohn’s strictures, activates human colonic fibroblasts to a fibrogenic phenotype. Matrix stiffness affects multiple pathways suggesting the mechanical properties of the cellular environment are critical to fibroblast function and may contribute to autopropagation of intestinal fibrosis in the absence of inflammation, thereby contributing to the intractable intestinal fibrosis characteristic of Crohn’s disease. PMID

  6. Delay-controlled primary and stochastic resonances of the SD oscillator with stiffness nonlinearities

    Science.gov (United States)

    Yang, Tao; Cao, Qingjie

    2018-03-01

    This work presents analytical studies of the stiffness nonlinearities SD (smooth and discontinuous) oscillator under displacement and velocity feedback control with a time delay. The SD oscillator can capture the qualitative characteristics of quasi-zero-stiffness and negative-stiffness. We focus mainly on the primary resonance of the quasi-zero-stiffness SD oscillator and the stochastic resonance (SR) of the negative-stiffness SD oscillator. Using the averaging method, we have been analyzed the amplitude response of the quasi-zero-stiffness SD oscillator. In this regard, the optimum time delay for changing the control intensity according to the optimization standard proposed can be obtained. For the optimum time delay, increasing the displacement feedback intensity is advantageous to suppress the vibrations in resonant regime where vibration isolation is needed, however, increasing the velocity feedback intensity is advantageous to strengthen the vibrations. Moreover, the effects of time-delayed feedback on the SR of the negative-stiffness SD oscillator are investigated under harmonic forcing and Gaussian white noise, based on the Langevin and Fokker-Planck approaches. The time-delayed feedback can enhance the SR phenomenon where vibrational energy harvesting is needed. This paper established the relationship between the parameters and vibration properties of a stiffness nonlinearities SD which provides the guidance for optimizing time-delayed control for vibration isolation and vibrational energy harvesting of the nonlinear systems.

  7. Stiffness Matters: Part II - The Effects of Plate Stiffness on Load-Sharing and the Progression of Fusion Following ACDF In Vivo.

    Science.gov (United States)

    Peterson, Joshua M; Chlebek, Carolyn; Clough, Ashley M; Wells, Alexandra K; Batzinger, Kathleen E; Houston, John M; Kradinova, Katerina; Glennon, Joseph C; DiRisio, Darryl J; Ledet, Eric H

    2018-03-19

    Real time in vivo measurement of forces in the cervical spine of goats following anterior cervical discectomy and fusion (ACDF). To measure interbody forces in the cervical spine during the time course of fusion following ACDF with plates of different stiffnesses. Following ACDF, the biomechanics of the arthrodesis is largely dictated by the plate. The properties of the plate prescribe the extent of load-sharing through the disc space versus the extent of stress-shielding. Load-sharing promotes interbody bone formation and stress-shielding can inhibit maturation of bone. However, these principles have never been validated in vivo. Measuring in vivo biomechanics of the cervical spine is critical to understanding the complex relationships between implant design, interbody loading, load-sharing, and the progression of fusion. Anterior cervical plates of distinct bending stiffnesses were placed surgically following ACDF in goats. A validated custom force-sensing interbody implant was placed in the disc space to measure load-sharing in the spine. Interbody loads were measured in vivo in real time during the course of fusion for each plate. Interbody forces during flexion/extension were highly dynamic. In animals that received high stiffness plates, maximum forces were in extension whereas in animals that received lower stiffness plates, maximum forces were in flexion. As fusion progressed, interbody load magnitude decreased. The magnitude of interbody forces in the cervical spine is dynamic and correlates to activity and posture of the head and neck. The magnitude and consistency of forces in the interbody space correlates to plate stiffness with more compliant plates resulting in more consistent load-sharing. The magnitude of interbody forces decreases as fusion matures suggesting that smart interbody implants may be used as a diagnostic tool to indicate the progression of interbody fusion. N/A.

  8. Probing the stiffness of isolated nucleoli by atomic force microscopy.

    Science.gov (United States)

    Louvet, Emilie; Yoshida, Aiko; Kumeta, Masahiro; Takeyasu, Kunio

    2014-04-01

    In eukaryotic cells, ribosome biogenesis occurs in the nucleolus, a membraneless nuclear compartment. Noticeably, the nucleolus is also involved in several nuclear functions, such as cell cycle regulation, non-ribosomal ribonucleoprotein complex assembly, aggresome formation and some virus assembly. The most intriguing question about the nucleolus is how such dynamics processes can occur in such a compact compartment. We hypothesized that its structure may be rather flexible. To investigate this, we used atomic force microscopy (AFM) on isolated nucleoli. Surface topography imaging revealed the beaded structure of the nucleolar surface. With the AFM's ability to measure forces, we were able to determine the stiffness of isolated nucleoli. We could establish that the nucleolar stiffness varies upon drastic morphological changes induced by transcription and proteasome inhibition. Furthermore, upon ribosomal proteins and LaminB1 knockdowns, the nucleolar stiffness was increased. This led us to propose a model where the nucleolus has steady-state stiffness dependent on ribosome biogenesis activity and requires LaminB1 for its flexibility.

  9. Stiff, light, strong and ductile: nano-structured High Modulus Steel.

    Science.gov (United States)

    Springer, H; Baron, C; Szczepaniak, A; Uhlenwinkel, V; Raabe, D

    2017-06-05

    Structural material development for lightweight applications aims at improving the key parameters strength, stiffness and ductility at low density, but these properties are typically mutually exclusive. Here we present how we overcome this trade-off with a new class of nano-structured steel - TiB 2 composites synthesised in-situ via bulk metallurgical spray-forming. Owing to the nano-sized dispersion of the TiB 2 particles of extreme stiffness and low density - obtained by the in-situ formation with rapid solidification kinetics - the new material has the mechanical performance of advanced high strength steels, and a 25% higher stiffness/density ratio than any of the currently used high strength steels, aluminium, magnesium and titanium alloys. This renders this High Modulus Steel the first density-reduced, high stiffness, high strength and yet ductile material which can be produced on an industrial scale. Also ideally suited for 3D printing technology, this material addresses all key requirements for high performance and cost effective lightweight design.

  10. MR elastography analysis of stiffness change induced by muscle contraction. President award proceedings

    International Nuclear Information System (INIS)

    Hata, Junichi; Yano, Keichi; Numano, Tomokazu; Yagi, Kazuo; Mizuhara, Kazuyuki; Washio, Toshikatsu; Homma, Kazuhiro; Takamoto, Koichi; Saijyo, Toshio

    2012-01-01

    Magnetic resonance elastography (MRE) was originally advocated in 1995 and has been the subject of recent attention. We employed MRE to characterize the stiffness of skeletal muscle of the lower thigh and changes in that stiffness. We obtained MRE images using a gradient recalled echo pulse sequence with parameters: repetition time (TR)/echo time (TE), 20/3.6 ms; number of excitations (NEX), 3; flip angle, 20deg; matrix, 512 x 512; scan time, 32 s; flex coil; and vibration frequency, 50 Hz. We made a vibration pad of 2 divergence types to excite the lower thigh from both sides evenly. When contraction and relaxation about the skeletal muscles, we enforced MRE. We drew regions of interest (ROI) on the stiffness images and measured it by using sclerometer to compare stiffness. We MRE enabled visualization of changes in the stiffness of skeletal muscles as a result of contraction and relaxation. The lateral gastrocnemius and soleus muscle demonstrated significant difference in stiffness at muscle contraction. MRE also permitted measurement of deep muscle using the muscle sclerometer. MRE allows evaluation of stiffness in a given biological section from the surface to deep tissue. (author)

  11. Unclassified haemolytic anaemia with splenomegaly and erythrocyte cation abnormalities - a disease of the spleen

    International Nuclear Information System (INIS)

    Bernard, J.F.; Bournier, O.; Renoux, M.; Charron, D.; Boivin, P.

    1976-01-01

    An unclassified case of haemolytic anaemia with voluminous splenomegaly is reported. This anaemia was normocytic without any specific morphologic aspect of red blood cells (RBC); Coombs test was negative; the osmotic fragility was normal; the increased autohaemolysis was not affected by the presence of glucose; Hb studies were normal; no RBC enzyme deficiency was found; RBC lipids and membrane proteins were normal; there was a marked reduction in RBC survival with exclusive splenic uptake of erythrocytes. Before splenectomy, RBC cations and water content were abnormal: 1) the RBC water was decreased moderately; 2) the RBC sodium was about twice the normal mean with an increased 22 Na turn-over; 3) the RBC potassium was markedly reduced and 42 K influx was twice the normal mean; 4) the RBC calcium content was increased. Splenectomy was followed by rapid disappearance of haemolysis and RBC water and cation disturbances. Because of this extremely rapid disappearance after splenectomy the authors suggest this case of haemolytic anaemia could be a primary disease of the spleen. (author)

  12. The conundrum of arterial stiffness, elevated blood pressure, and aging.

    Science.gov (United States)

    AlGhatrif, Majd; Lakatta, Edward G

    2015-02-01

    Isolated systolic hypertension is a major health burden that is expanding with the aging of our population. There is evidence that central arterial stiffness contributes to the rise in systolic blood pressure (SBP); at the same time, central arterial stiffening is accelerated in patients with increased SBP. This bidirectional relationship created a controversy in the field on whether arterial stiffness leads to hypertension or vice versa. Given the profound interdependency of arterial stiffness and blood pressure, this question seems intrinsically challenging, or probably naïve. The aorta's function of dampening the pulsatile flow generated by the left ventricle is optimal within a physiological range of distending pressure that secures the required distal flow, keeps the aorta in an optimal mechanical conformation, and minimizes cardiac work. This homeostasis is disturbed by age-associated, minute alterations in aortic hemodynamic and mechanical properties that induce short- and long-term alterations in each other. Hence, it is impossible to detect an "initial insult" at an epidemiological level. Earlier manifestations of these alterations are observed in young adulthood with a sharp decline in aortic strain and distensibility accompanied by an increase in diastolic blood pressure. Subsequently, aortic mechanical reserve is exhausted, and aortic remodeling with wall stiffening and dilatation ensue. These two phenomena affect pulse pressure in opposite directions and different magnitudes. With early remodeling, there is an increase in pulse pressure, due to the dominance of arterial wall stiffness, which in turn accelerates aortic wall stiffness and dilation. With advanced remodeling, which appears to be greater in men, the effect of diameter becomes more pronounced and partially offsets the effect of wall stiffness leading to plateauing in pulse pressure in men and slower increase in pulse pressure (PP) than that of wall stiffness in women. The complex nature of

  13. Evidence that breast tissue stiffness is associated with risk of breast cancer.

    Science.gov (United States)

    Boyd, Norman F; Li, Qing; Melnichouk, Olga; Huszti, Ella; Martin, Lisa J; Gunasekara, Anoma; Mawdsley, Gord; Yaffe, Martin J; Minkin, Salomon

    2014-01-01

    Evidence from animal models shows that tissue stiffness increases the invasion and progression of cancers, including mammary cancer. We here use measurements of the volume and the projected area of the compressed breast during mammography to derive estimates of breast tissue stiffness and examine the relationship of stiffness to risk of breast cancer. Mammograms were used to measure the volume and projected areas of total and radiologically dense breast tissue in the unaffected breasts of 362 women with newly diagnosed breast cancer (cases) and 656 women of the same age who did not have breast cancer (controls). Measures of breast tissue volume and the projected area of the compressed breast during mammography were used to calculate the deformation of the breast during compression and, with the recorded compression force, to estimate the stiffness of breast tissue. Stiffness was compared in cases and controls, and associations with breast cancer risk examined after adjustment for other risk factors. After adjustment for percent mammographic density by area measurements, and other risk factors, our estimate of breast tissue stiffness was significantly associated with breast cancer (odds ratio = 1.21, 95% confidence interval = 1.03, 1.43, p = 0.02) and improved breast cancer risk prediction in models with percent mammographic density, by both area and volume measurements. An estimate of breast tissue stiffness was associated with breast cancer risk and improved risk prediction based on mammographic measures and other risk factors. Stiffness may provide an additional mechanism by which breast tissue composition is associated with risk of breast cancer and merits examination using more direct methods of measurement.

  14. Radioprotective activity of the Piper betle-derived phenolic, allylpyrocatechol against gamma-ray induced hemolysis of human red blood cells

    International Nuclear Information System (INIS)

    Meenakshi, K.; Chattopadhyay, S.

    2016-01-01

    As an oxidative shuttle, human (RBCs) are most susceptible to oxidative damages leading to multiple diseases including haemolytic anemia that is a major public health problem in the developing countries. The present effort was aimed at formulating some natural phenolic compounds isolated from piper betle - allylpyrocatechol (APC) to prevent the alterations in the RBC membrane. The biochemical parameters which are considered as biomarkers of redox balance primarily contribute to damages in RBC membrane during gamma radiation induced oxidative stress were investigated

  15. Efficient and Specific Analysis of Red Blood Cell Glycerophospholipid Fatty Acid Composition

    OpenAIRE

    Klem, Sabrina; Klingler, Mario; Demmelmair, Hans; Koletzko, Berthold

    2012-01-01

    BACKGROUND: Red blood cell (RBC) n-3 fatty acid status is related to various health outcomes. Accepted biological markers for the fatty acid status determination are RBC phospholipids, phosphatidylcholine, and phosphatidyletholamine. The analysis of these lipid fractions is demanding and time consuming and total phospholipid n-3 fatty acid levels might be affected by changes of sphingomyelin contents in the RBC membrane during n-3 supplementation. AIM: We developed a method for the specific a...

  16. A variable stiffness mechanism for steerable percutaneous instruments: integration in a needle.

    Science.gov (United States)

    De Falco, Iris; Culmone, Costanza; Menciassi, Arianna; Dankelman, Jenny; van den Dobbelsteen, John J

    2018-06-04

    Needles are advanced tools commonly used in minimally invasive medical procedures. The accurate manoeuvrability of flexible needles through soft tissues is strongly determined by variations in tissue stiffness, which affects the needle-tissue interaction and thus causes needle deflection. This work presents a variable stiffness mechanism for percutaneous needles capable of compensating for variations in tissue stiffness and undesirable trajectory changes. It is composed of compliant segments and rigid plates alternately connected in series and longitudinally crossed by four cables. The tensioning of the cables allows the omnidirectional steering of the tip and the stiffness tuning of the needle. The mechanism was tested separately under different working conditions, demonstrating a capability to exert up to 3.6 N. Afterwards, the mechanism was integrated into a needle, and the overall device was tested in gelatine phantoms simulating the stiffness of biological tissues. The needle demonstrated the capability to vary deflection (from 11.6 to 4.4 mm) and adapt to the inhomogeneity of the phantoms (from 21 to 80 kPa) depending on the activation of the variable stiffness mechanism. Graphical abstract ᅟ.

  17. Fabrication of hydrogels with steep stiffness gradients for studying cell mechanical response.

    Directory of Open Access Journals (Sweden)

    Raimon Sunyer

    Full Text Available Many fundamental cell processes, such as angiogenesis, neurogenesis and cancer metastasis, are thought to be modulated by extracellular matrix stiffness. Thus, the availability of matrix substrates having well-defined stiffness profiles can be of great importance in biophysical studies of cell-substrate interaction. Here, we present a method to fabricate biocompatible hydrogels with a well defined and linear stiffness gradient. This method, involving the photopolymerization of films by progressively uncovering an acrylamide/bis-acrylamide solution initially covered with an opaque mask, can be easily implemented with common lab equipment. It produces linear stiffness gradients of at least 115 kPa/mm, extending from ∼1 kPa to 240 kPa (in units of Young's modulus. Hydrogels with less steep gradients and narrower stiffness ranges can easily be produced. The hydrogels can be covalently functionalized with uniform coatings of proteins that promote cell adhesion. Cell spreading on these hydrogels linearly correlates with hydrogel stiffness, indicating that this technique effectively modifies the mechanical environment of living cells. This technique provides a simple approach that produces steeper gradients, wider rigidity ranges, and more accurate profiles than current methods.

  18. Measurement of stiffness of standing trees and felled logs using acoustics: A review.

    Science.gov (United States)

    Legg, Mathew; Bradley, Stuart

    2016-02-01

    This paper provides a review on the use of acoustics to measure stiffness of standing trees, stems, and logs. An outline is given of the properties of wood and how these are related to stiffness and acoustic velocity throughout the tree. Factors are described that influence the speed of sound in wood, including the different types of acoustic waves which propagate in tree stems and lumber. Acoustic tools and techniques that have been used to measure the stiffness of wood are reviewed. The reasons for a systematic difference between direct and acoustic measurements of stiffness for standing trees, and methods for correction, are discussed. Other techniques, which have been used in addition to acoustics to try to improve stiffness measurements, are also briefly described. Also reviewed are studies which have used acoustic tools to investigate factors that influence the stiffness of trees. These factors include different silvicultural practices, geographic and environmental conditions, and genetics.

  19. Response of stiff piles in sand to long-term cyclic lateral loading

    DEFF Research Database (Denmark)

    Bakmar, Christian LeBlanc; Houlsby, Guy T.; Byrne, Byron W.

    2010-01-01

    . To address this, a series of laboratory tests were conducted where a stiff pile in drained sand was subjected to between 8000 and 60000 cycles of combined moment and horizontal loading. A typical design for an offshore wind turbine monopile was used as a basis for the study, to ensure that pile dimensions...... and loading ranges were realistic. A complete non-dimensional framework for stiff piles in sand is presented and applied to interpret the test results. The accumulated rotation was found to be dependent on relative density and was strongly affected by the characteristics of the applied cyclic load. The pile...... stiffness increased with number of cycles, which contrasts with the current methodology where static p - y curves are degraded to account for cyclic loading. Methods are presented to predict the change in stiffness and the accumulated rotation of a stiff pile due to long-term cyclic loading. The use...

  20. Comparison of the Mechanical Properties of Early Leukocyte- and Platelet-Rich Fibrin versus PRGF/Endoret Membranes

    Directory of Open Access Journals (Sweden)

    Hooman Khorshidi

    2016-01-01

    Full Text Available Objectives. The mechanical properties of membranes are important factors in the success of treatment and clinical handling. The goal of this study was to compare the mechanical properties of early leukocyte- and platelet-rich fibrin (L-PRF versus PRGF/Endoret membrane. Materials and Methods. In this experimental study, membranes were obtained from 10 healthy male volunteers. After obtaining 20 cc venous blood from each volunteer, 10 cc was used to prepare early L-PRF (group 1 and the rest was used to get a membrane by PRGF-Endoret system (group 2. Tensile loads were applied to specimens using universal testing machine. Tensile strength, stiffness, and toughness of the two groups of membranes were calculated and compared by paired t-test. Results. The mean tensile strength and toughness were higher in group 1 with a significant difference (P0.05. Conclusions. The results showed that early L-PRF membranes had stronger mechanical properties than membranes produced by PRGF-Endoret system. Early L-PRF membranes might have easier clinical handling and could be a more proper scaffold in periodontal regenerative procedures. The real results of the current L-PRF should be in fact much higher than what is reported here.

  1. Comparison of the Mechanical Properties of Early Leukocyte- and Platelet-Rich Fibrin versus PRGF/Endoret Membranes.

    Science.gov (United States)

    Khorshidi, Hooman; Raoofi, Saeed; Bagheri, Rafat; Banihashemi, Hodasadat

    2016-01-01

    Objectives. The mechanical properties of membranes are important factors in the success of treatment and clinical handling. The goal of this study was to compare the mechanical properties of early leukocyte- and platelet-rich fibrin (L-PRF) versus PRGF/Endoret membrane. Materials and Methods. In this experimental study, membranes were obtained from 10 healthy male volunteers. After obtaining 20 cc venous blood from each volunteer, 10 cc was used to prepare early L-PRF (group 1) and the rest was used to get a membrane by PRGF-Endoret system (group 2). Tensile loads were applied to specimens using universal testing machine. Tensile strength, stiffness, and toughness of the two groups of membranes were calculated and compared by paired t-test. Results. The mean tensile strength and toughness were higher in group 1 with a significant difference (P 0.05). Conclusions. The results showed that early L-PRF membranes had stronger mechanical properties than membranes produced by PRGF-Endoret system. Early L-PRF membranes might have easier clinical handling and could be a more proper scaffold in periodontal regenerative procedures. The real results of the current L-PRF should be in fact much higher than what is reported here.

  2. Vibration Isolation System Using Negative Stiffness(Advances in Motion and Vibration Control Technology)

    OpenAIRE

    水野, 毅; 高崎, 正也

    2003-01-01

    A new vibration isolation system using negative stiffness realized by active control technique is proposed in this paper. The serial connection of a normal spring and a suspension system with negative stiffness enables the isolation system to have low stiffness for vibration from the ground and high (theoretically infinite) stiffness against direct disturbance acting on the isolation table. A control method of realizing negative stiffness with a linear actuator is presented in an analytical f...

  3. Modifiable risk factors for increased arterial stiffness in outpatient nephrology.

    Directory of Open Access Journals (Sweden)

    Usama Elewa

    Full Text Available Arterial stiffness, as measured by pulse wave velocity (PWV, is an independent predictor of cardiovascular events and mortality. Arterial stiffness increases with age. However, modifiable risk factors such as smoking, BP and salt intake also impact on PWV. The finding of modifiable risk factors may lead to the identification of treatable factors, and, thus, is of interest to practicing nephrologist. We have now studied the prevalence and correlates of arterial stiffness, assessed by PWV, in 191 patients from nephrology outpatient clinics in order to identify modifiable risk factors for arterial stiffness that may in the future guide therapeutic decision-making. PWV was above normal levels for age in 85/191 (44.5% patients. Multivariate analysis showed that advanced age, systolic BP, diabetes mellitus, serum uric acid and calcium polystyrene sulfonate therapy or calcium-containing medication were independent predictors of PWV. A new parameter, Delta above upper limit of normal PWV (Delta PWV was defined to decrease the weight of age on PWV values. Delta PWV was calculated as (measured PWV - (upper limit of the age-adjusted PWV values for the general population. Mean±SD Delta PWV was 0.76±1.60 m/sec. In multivariate analysis, systolic blood pressure, active smoking and calcium polystyrene sulfonate therapy remained independent predictors of higher delta PWV, while age, urinary potassium and beta blocker therapy were independent predictors of lower delta PWV. In conclusion, arterial stiffness was frequent in nephrology outpatients. Systolic blood pressure, smoking, serum uric acid, calcium-containing medications, potassium metabolism and non-use of beta blockers are modifiable factors associated with increased arterial stiffness in Nephrology outpatients.

  4. Fitness as a determinant of arterial stiffness in healthy adult men: a cross-sectional study.

    Science.gov (United States)

    Chung, Jinwook; Kim, Milyang; Jin, Youngsoo; Kim, Yonghwan; Hong, Jeeyoung

    2018-01-01

    Fitness is known to influence arterial stiffness. This study aimed to assess differences in cardiorespiratory endurance, muscular strength, and flexibility according to arterial stiffness, based on sex and age. We enrolled 1590 healthy adults (men: 1242, women: 348) who were free of metabolic syndrome. We measured cardiorespiratory endurance in an exercise stress test on a treadmill, muscular strength by a grip test, and flexibility by upper body forward-bends from a standing position. The brachial-ankle pulse wave velocity test was performed to measure arterial stiffness before the fitness test. Cluster analysis was performed to divide the patients into groups with low (Cluster 1) and high (Cluster 2) arterial stiffness. According to the k-cluster analysis results, Cluster 1 included 624 men and 180 women, and Cluster 2 included 618 men and 168 women. Men in the middle-aged group with low arterial stiffness demonstrated higher cardiorespiratory endurance, muscular strength, and flexibility than those with high arterial stiffness. Similarly, among men in the old-aged group, the cardiorespiratory endurance and muscular strength, but not flexibility, differed significantly according to arterial stiffness. Women in both clusters showed similar cardiorespiratory endurance, muscular strength, and flexibility regardless of their arterial stiffness. Among healthy adults, arterial stiffness was inversely associated with fitness in men but not in women. Therefore, fitness seems to be a determinant for arterial stiffness in men. Additionally, regular exercise should be recommended for middle-aged men to prevent arterial stiffness.

  5. Study of stiffness and bearing capacity degradation of reinforced concrete beams under constant-amplitude fatigue.

    Science.gov (United States)

    Liu, Fangping; Zhou, Jianting; Yan, Lei

    2018-01-01

    For a reinforced concrete beam subjected to fatigue loads, the structural stiffness and bearing capacity will gradually undergo irreversible degeneration, leading to damage. Moreover, there is an inherent relationship between the stiffness and bearing capacity degradation and fatigue damage. In this study, a series of fatigue tests are performed to examine the degradation law of the stiffness and bearing capacity. The results pertaining to the stiffness show that the stiffness degradation of a reinforced concrete beam exhibits a very clear monotonic decreasing "S" curve, i.e., the stiffness of the beam decreases significantly at the start of the fatigue loading, it undergoes a linear decline phase in the middle for a long loading period, and before the failure, the bearing capacity decreases drastically again. The relationship between the residual stiffness and residual bearing capacity is determined based on the assumption that the residual stiffness and residual bearing capacity depend on the same damage state, and then, the bearing capacity degradation model of the reinforced concrete beam is established based on the fatigue stiffness. Through the established model and under the premise of the known residual stiffness degradation law, the degradation law of the bearing capacity is determined by using at least one residual bearing capacity test data, for which the parameters of the stiffness degradation function are considered as material constants. The results of the bearing capacity show that the bearing capacity degradation of the reinforced concrete beam also exhibits a very clear monotonic decreasing "S" curve, which is consistent with the stiffness degradation process and in good agreement with the experiment. In this study, the stiffness and bearing capacity degradation expressions are used to quantitatively describe their occurrence in reinforced concrete beams. In particular, the expression of the bearing capacity degradation can mitigate numerous

  6. Research on Biomimetic Models and Nanomechanical Behaviour of Membranous Wings of Chinese Bee Apis cerana cerana Fabricius

    Directory of Open Access Journals (Sweden)

    Yanru Zhao

    2018-01-01

    Full Text Available The structures combining the veins and membranes of membranous wings of the Chinese bee Apis cerana cerana Fabricius into a whole have excellent load-resisting capacity. The membranous wings of Chinese bees were taken as research objects and the mechanical properties of a biomimetic model of membranous wings as targets. In order to understand and learn from the biosystem and then make technical innovation, the membranous wings of Chinese bees were simulated and analysed with reverse engineering and finite element method. The deformations and stress states of the finite element model of membranous wings were researched under the concentrated force, uniform load, and torque. It was found that the whole model deforms evenly and there are no unusual deformations arising. The displacements and deformations are small and transform uniformly. It was indicated that the veins and membranes combine well into a whole to transmit loads effectively, which illustrates the membranous wings of Chinese bees having excellent integral mechanical behaviour and structure stiffness. The realization of structure models of the membranous wings of Chinese bees and analysis of the relativity of structures and performances or functions will provide an inspiration for designing biomimetic thin-film materials with superior load-bearing capacity.

  7. Longitudinal relaxation of initially straight flexible and stiff polymers

    Science.gov (United States)

    Dimitrakopoulos, Panagiotis; Dissanayake, Inuka

    2004-11-01

    The present talk considers the relaxation of a single flexible or stiff polymer chain from an initial straight configuration in a viscous solvent. This problem commonly arises when strong flows are turned off in both industrial and biological applications. The problem is also motivated by recent experiments with single biopolymer molecules relaxing after being fully extended by applied forces as well as by the recent development of micro-devices involving stretched tethered biopolymers. Our results are applicable to a wide array of synthetic polymers such as polyacrylamides, Kevlar and polyesters as well as biopolymers such as DNA, actin filaments, microtubules and MTV. In this talk we discuss the mechanism of the polymer relaxation as was revealed through Brownian Dynamics simulations covering a broad range of time scales and chain stiffness. After the short-time free diffusion, the chain's longitudinal reduction at early intermediate times is shown to constitute a universal behavior for any chain stiffness caused by a quasi-steady relaxation of tensions associated with the deforming action of the Brownian forces. Stiff chains are shown to exhibit a late intermediate-time longitudinal reduction associated with a relaxation of tensions affected by the deforming Brownian and the restoring bending forces. The longitudinal and transverse relaxations are shown to obey different laws, i.e. the chain relaxation is anisotropic at all times. In the talk, we show how from the knowledge of the relaxation mechanism, we can predict and explain the polymer properties including the polymer stress and the solution birefringence. In addition, a generalized stress-optic law is derived valid for any time and chain stiffness. All polymer properties which depend on the polymer length are shown to exhibit two intermediate-time behaviors with the early one to constitute a universal behavior for any chain stiffness. This work was supported in part by the Minta Martin Research Fund. The

  8. Music decreases aortic stiffness and wave reflections.

    Science.gov (United States)

    Vlachopoulos, Charalambos; Aggelakas, Angelos; Ioakeimidis, Nikolaos; Xaplanteris, Panagiotis; Terentes-Printzios, Dimitrios; Abdelrasoul, Mahmoud; Lazaros, George; Tousoulis, Dimitris

    2015-05-01

    Music has been related to cardiovascular health and used as adjunct therapy in patients with cardiovascular disease. Aortic stiffness and wave reflections are predictors of cardiovascular risk. We investigated the short-term effect of classical and rock music on arterial stiffness and wave reflections. Twenty healthy individuals (22.5±2.5 years) were studied on three different occasions and listened to a 30-min music track compilation (classical, rock, or no music for the sham procedure). Both classical and rock music resulted in a decrease of carotid-femoral pulse wave velocity (PWV) immediately after the end of music listening (all pclassical or rock music in a more sustained way (nadir by 6.0% and 5.8%, respectively, at time zero post-music listening, all pmusic preference was taken into consideration, both classical and rock music had a more potent effect on PWV in classical aficionados (by 0.20 m/s, p=0.003 and 0.13 m/s, p=0.015, respectively), whereas there was no effect in rock aficionados (all p=NS). Regarding wave reflections, classical music led to a more potent response in classical aficionados (AIx decrease by 9.45%), whereas rock led to a more potent response to rock aficionados (by 10.7%, all pMusic, both classical and rock, decreases aortic stiffness and wave reflections. Effect on aortic stiffness lasts for as long as music is listened to, while classical music has a sustained effect on wave reflections. These findings may have important implications, extending the spectrum of lifestyle modifications that can ameliorate arterial function. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. A comparative study on free vibration analysis of delaminated torsion stiff and bending stiff composite shells

    International Nuclear Information System (INIS)

    Dey, Sudip; Karmakar, Amit

    2013-01-01

    This paper presents a finite element method to compare the effects of delamination on free vibration of graphite-epoxy bending stiff and torsion stiff composite pretwisted shallow conical shells. The generalized dynamic equilibrium equation is derived from Lagrange's equation of motion neglecting the Coriolis effect for moderate rotational speeds. An eight noded isoparametric plate bending element is employed incorporating rotary inertia and effects of transverse shear deformation based on Mindlin's theory. The multipoint constraint; algorithm is utilized to ensure the compatibility of deformation and equilibrium of resultant forces and moments at the delamination crack front. The standard eigen value problem is solved by applying the QR iteration algorithm. Mode shapes for typical configurations are also depicted. Numerical results obtained are the first known non-dimensional frequencies which could serve as reference solutions for the future investigators.

  10. Dynamic Bending and Torsion Stiffness Derivation from Modal Curvatures and Torsion Rates

    Science.gov (United States)

    MAECK, J.; DE ROECK, G.

    1999-08-01

    In order to maintain the reliability of civil engineering structures, considerable effort is currently spent on developing a non-destructive vibration testing method for monitoring the structural integrity of constructions. The technique must be able to observe damage, secondly to localize the damage; and finally to give an idea of the severity of the damage. Within the framework of relating changes of measured modal parameters to changes in the integrity of the structure, it is important to be able to determine the dynamic stiffness in each section of the structure from measured modal characteristics.A damaged structure results in a dynamic stiffness reduction of the cracked sections. The dynamic stiffnesses provide directly an indication of the extension of the cracked zones in the structure. The dynamic stiffness reduction can also be associated with a degree of cracking in a particular zone.In an experimental programme, a concrete beam of 6 m length is subjected to an increasing static load to produce cracks. After each static perload, the beam is tested dynamically in a free-free set-up. The change in modal parameters is then related to damage in the beam.The technique that will be presented in the paper to predict the damage location and intensity is a direct stiffness derivation from measured modal displacement derivatives. Using the bending modes, the dynamic bending stiffness can be derived from modal curvatures. Using the torsional modes, the dynamic torsion stiffness can be derived from modal torsion rates.

  11. Comparison of cervical spine stiffness in individuals with chronic nonspecific neck pain and asymptomatic individuals.

    Science.gov (United States)

    Ingram, Lewis A; Snodgrass, Suzanne J; Rivett, Darren A

    2015-03-01

    Clinical measurement, cross-sectional. To determine if spinal joint stiffness is different in individuals with nonspecific neck pain, and whether stiffness magnitude is associated with pain intensity and disability. Manual therapists commonly evaluate spinal joint stiffness in patients presenting with nonspecific neck pain. However, a relationship between stiffness and neck pain has not yet been demonstrated. Spinal stiffness at C7 was objectively measured in participants with chronic nonspecific neck pain whose symptomatic spinal level was identified as C7 (n = 12) and in age- and sex-matched asymptomatic controls (n = 12). Stiffness (slope of the linear region of the force-displacement curve) was quantified using a device that applied 5 standardized mechanical force cycles to the C7 spinous process, while concurrently measuring displacement and resistance to movement. Stiffness was compared between groups using an independent t test. Spearman rho and Pearson r were used to determine the extent to which stiffness magnitude was associated with pain intensity (visual analog scale) and level of disability (Neck Disability Index), respectively, in the group with neck pain. Participants with nonspecific neck pain had greater spinal joint stiffness at C7 compared with asymptomatic individuals (mean difference, 1.78 N/mm; 95% confidence interval: 0.28, 3.27; P = .022). However, stiffness magnitude in the group with neck pain was not associated (P>.05) with pain intensity or level of disability. These preliminary results suggest that cervical spine stiffness may be greater in the presence of nonspecific neck pain. However, judgments regarding pain intensity and level of disability should not be inferred from examinations of spinal joint stiffness.

  12. A prototype of a novel energy efficient variable stiffness actuator

    NARCIS (Netherlands)

    Visser, L.C.; Carloni, Raffaella; Klijnstra, F.; Stramigioli, Stefano

    In this work, we present a proof of concept of a novel variable stiffness actuator. The actuator design is based on the conceptual design proposed in earlier work, and is such that the apparent output stiffness of the actuator can be changed independently of the output position and without any

  13. Taxonomy, phylogenetics and biogeography of Chesneya (Fabaceae), evidenced from data of three sequences, ITS, trnS-trnG, and rbcL

    Science.gov (United States)

    Ming-Li Zhang; Zhi-Bin Wen; Xiao-Li Hao; Vyacheslav V. Byalt; Alexander P. Sukhorukov; Stewart C. Sanderson

    2015-01-01

    Plants of Central Asia have played a significant role in the origin of floras of Eurasia and the Northern Hemisphere. Chesneya, a small leguminous genus occurring in Central Asia, western Asia, and Tibet, is used to establish phylogenetic relationships and discuss the evolutionary and biogeographical history based on sequence data of ITS and trnS-trnG and rbcL.We...

  14. Inverse axial mounting stiffness design for lithographic projection lenses.

    Science.gov (United States)

    Wen-quan, Yuan; Hong-bo, Shang; Wei, Zhang

    2014-09-01

    In order to balance axial mounting stiffness of lithographic projection lenses and the image quality under dynamic working conditions, an easy inverse axial mounting stiffness design method is developed in this article. Imaging quality deterioration at the wafer under different axial vibration levels is analyzed. The desired image quality can be determined according to practical requirements, and axial vibrational tolerance of each lens is solved with the damped least-squares method. Based on adaptive interval adjustment, a binary search algorithm, and the finite element method, the axial mounting stiffness of each lens can be traveled in a large interval, and converges to a moderate numerical solution which makes the axial vibrational amplitude of the lens converge to its axial vibrational tolerance. Model simulation is carried out to validate the effectiveness of the method.

  15. Membrane Vesicles of Group B Streptococcus Disrupt Feto-Maternal Barrier Leading to Preterm Birth.

    Directory of Open Access Journals (Sweden)

    Manalee Vishnu Surve

    2016-09-01

    Full Text Available Infection of the genitourinary tract with Group B Streptococcus (GBS, an opportunistic gram positive pathogen, is associated with premature rupture of amniotic membrane and preterm birth. In this work, we demonstrate that GBS produces membrane vesicles (MVs in a serotype independent manner. These MVs are loaded with virulence factors including extracellular matrix degrading proteases and pore forming toxins. Mice chorio-decidual membranes challenged with MVs ex vivo resulted in extensive collagen degradation leading to loss of stiffness and mechanical weakening. MVs when instilled vaginally are capable of anterograde transport in mouse reproductive tract. Intra-amniotic injections of GBS MVs in mice led to upregulation of pro-inflammatory cytokines and inflammation mimicking features of chorio-amnionitis; it also led to apoptosis in the chorio-decidual tissue. Instillation of MVs in the amniotic sac also resulted in intrauterine fetal death and preterm delivery. Our findings suggest that GBS MVs can independently orchestrate events at the feto-maternal interface causing chorio-amnionitis and membrane damage leading to preterm birth or fetal death.

  16. Membrane Vesicles of Group B Streptococcus Disrupt Feto-Maternal Barrier Leading to Preterm Birth

    Science.gov (United States)

    Sthanam, Lakshmi Kavitha; Srivastava, Rohit; Basu, Bhakti; Dutta, Suryendu; Sen, Shamik; Modi, Deepak

    2016-01-01

    Infection of the genitourinary tract with Group B Streptococcus (GBS), an opportunistic gram positive pathogen, is associated with premature rupture of amniotic membrane and preterm birth. In this work, we demonstrate that GBS produces membrane vesicles (MVs) in a serotype independent manner. These MVs are loaded with virulence factors including extracellular matrix degrading proteases and pore forming toxins. Mice chorio-decidual membranes challenged with MVs ex vivo resulted in extensive collagen degradation leading to loss of stiffness and mechanical weakening. MVs when instilled vaginally are capable of anterograde transport in mouse reproductive tract. Intra-amniotic injections of GBS MVs in mice led to upregulation of pro-inflammatory cytokines and inflammation mimicking features of chorio-amnionitis; it also led to apoptosis in the chorio-decidual tissue. Instillation of MVs in the amniotic sac also resulted in intrauterine fetal death and preterm delivery. Our findings suggest that GBS MVs can independently orchestrate events at the feto-maternal interface causing chorio-amnionitis and membrane damage leading to preterm birth or fetal death. PMID:27583406

  17. Bio-inspired composites with functionally graded platelets exhibit enhanced stiffness.

    Science.gov (United States)

    Tapse, Sanjay; S, Anup

    2017-11-09

    Unidirectional composites inspired from biological materials such as nacre, are composed of stiff platelets arranged in a staggered manner within a soft matrix. Elaborate analyses have been conducted on the aforementioned composites and they are found to have excellent mechanical properties like stiffness, strength and fracture toughness. The superior properties exhibited by these composites have been proved to be the result of its unique structure. An emerging development in the field of composite structures is Functionally Graded Composites(FGC), whose properties vary spatially and possess enhanced thermo-mechanical properties. In this paper, the platelets are functionally graded with its Young's Modulus varying parabolically along the length. Two different models - namely, Tension Shear Chain Model and Minimisation of Complementary Energy Model have been employed to obtain the stiffness of the overall composite analytically. The effect of various parameters that define the composite model such as overlapping length between any two neighbouring platelets, different gradation parameters and platelet aspect ratio on the overall mechanical properties have been studied. Composites with functionally graded platelets are found to possess enhanced stiffness (upto 14% higher) for certain values of these parameters. The obtained solutions have been validated using Finite Element Analysis. Bio-inspired composites with functionally graded platelets can be engineered for structural applications, such as in automobile, aerospace and aircraft industry, where stiffness plays a crucial role. © 2017 IOP Publishing Ltd.

  18. A two-locus global DNA barcode for land plants: the coding rbcL gene complements the non-coding trnH-psbA spacer region.

    Science.gov (United States)

    Kress, W John; Erickson, David L

    2007-06-06

    A useful DNA barcode requires sufficient sequence variation to distinguish between species and ease of application across a broad range of taxa. Discovery of a DNA barcode for land plants has been limited by intrinsically lower rates of sequence evolution in plant genomes than that observed in animals. This low rate has complicated the trade-off in finding a locus that is universal and readily sequenced and has sufficiently high sequence divergence at the species-level. Here, a global plant DNA barcode system is evaluated by comparing universal application and degree of sequence divergence for nine putative barcode loci, including coding and non-coding regions, singly and in pairs across a phylogenetically diverse set of 48 genera (two species per genus). No single locus could discriminate among species in a pair in more than 79% of genera, whereas discrimination increased to nearly 88% when the non-coding trnH-psbA spacer was paired with one of three coding loci, including rbcL. In silico trials were conducted in which DNA sequences from GenBank were used to further evaluate the discriminatory power of a subset of these loci. These trials supported the earlier observation that trnH-psbA coupled with rbcL can correctly identify and discriminate among related species. A combination of the non-coding trnH-psbA spacer region and a portion of the coding rbcL gene is recommended as a two-locus global land plant barcode that provides the necessary universality and species discrimination.

  19. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia; Measurement of cerebral blood volume (CBV) with sup 99m Tc-RBC SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo (Hokkaido Neurosurgical Memorial Hospital (Japan)); Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi

    1990-03-01

    To evaluate the efficacy of tests for selecting patients with hemodynamic compromise, measurement of cerebral blood volume (CBV) with {sup 99m}Tc-RBC single photon emission computed tomography (SPECT) was performed in thirteen patients with occlusive cerebrovascular disease, and was compared with results obtained by {sup 133}Xe SPECT and acetazolamide (Diamox) test. All patients in our study suffered TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery, although plain CT scan or MRI revealed no or, if any, only localized infarcted lesions. Regional cerebral blood volume (rCBV) was measured with {sup 99m}Tc-RBC SPECT and regional cerebral blood flow (rCBF) was measured with {sup 133}Xe SPECT before and after intravenous injection of 10 - 12 mg/kg acetazolamide (Diamox). Our results suggest that the ipsilateral rCBV/rCBF (mean transit time) is a more sensitive index of the cerebral perfusion reserve than the use of only rCBV or rCBF of the ipsilateral hemisphere. Also, the ipsilateral rCBV/rCBF is significantly correlated (r= -0.72) with the Diamox reactivity of rCBF, which is considered to represent the cerebral vasodilatory capacity in patients with chronic cerebral ischemia. Postoperative SPECT study revealed remarkable improvement of ipsilateral rCBV/rCBF and Diamox reactivity in four patients who underwent EC/IC bypass surgery to improve the hemodynamic compromise. In conclusion, our results suggest that the measurement of rCBV/rCBF with {sup 133}Xe SPECT and {sup 99m}Tc-RBC SPECT is useful for detecting the hemodynamic compromise in patients with occlusive cerebrovascular disease. (author).

  20. Electrothermally Actuated Microbeams With Varying Stiffness

    KAUST Repository

    Tella, Sherif Adekunle

    2017-11-03

    We present axially loaded clamped-guided microbeams that can be used as resonators and actuators of variable stiffness, actuation, and anchor conditions. The applied axial load is implemented by U-shaped electrothermal actuators stacked at one of the beams edges. These can be configured and wired in various ways, which serve as mechanical stiffness elements that control the operating resonance frequency of the structures and their static displacement. The experimental results have shown considerable increase in the resonance frequency and mid-point deflection of the microbeam upon changing the end conditions of the beam. These results can be promising for applications requiring large deflection and high frequency tunability, such as filters, memory devices, and switches. The experimental results are compared to multi-physics finite-element simulations showing good agreement among them.

  1. Substrate stiffness promotes latent TGF-β1 activation in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Pang, Mingshu; Teng, Yao; Huang, Jianyong; Yuan, Yuan; Lin, Feng; Xiong, Chunyang

    2017-01-01

    Hepatocellular carcinoma (HCC) was usually coupled with increased stiffness of the extracellular matrix (ECM) and elevated level of transforming growth factor-β1 (TGF-β1). However, the mechanism by which substrate rigidity modulated TGF-β1 signaling transduction remained unknown. This paper investigated the molecular mechanism of how matrix stiffness regulating TGF-β1 signaling in HCC cells. By means of stiffness tunable collagen I-coated polyacrylamide (PA) gels, we found that the expressions of β1 integrin, p-FAK Y397 and p-Smad2 upregulated on stiffer gels as well as the content of TGF-β1 in culture media of HCC cells, which were inhibited by RGD blocking peptides, Y-27632 (ROCK inhibitor) or Blebbistatin (myosin II inhibitor). Cellular traction force was also significantly higher when plated on stiffer substrates but dramatically decreased after treatment with Y-27632 or Blebbistatin. Furthermore, the upregulation of p-Smad2 in the HCC cells on stiffer PA gels induced by exogenetic latent TGF-β1 was downregulated in the presence of RGD peptides. The nuclear translocation of Smad2 induced by latent TGF-β1 was inhibited by Y-27632 or Blebbistatin. Our results suggested that the extracellular matrix stiffness regulated latent TGF-β1 activation by cytoskeletal tension in HCC cells, showing that matrix stiffness was a key regulator involving the TGF-β1 activity in HCC cells. The current study presented a mechanism of how hepatocirrhosis developed into liver cancer. - Highlights: • TGF-β1 signaling pathway regulated by ECM stiffness was studied in hepatocellular carcinoma. • Matrix stiffness promoted latent TGF-β1 activation via β1 integrin-FAK-Rho GTPase pathway. • A mechanism of how hepatocirrhosis developed into liver cancer was presented.

  2. Detection and quantification of Duffy antigen on bovine red blood cell membranes using a polyclonal antibody

    Directory of Open Access Journals (Sweden)

    Ana Teresa B.F. Antonangelo

    2012-09-01

    Full Text Available Babesiosis is one of the most important diseases affecting livestock agriculture worldwide. Animals from the subspecies Bos taurus indicus are more resistant to babesiosis than those from Bos taurus taurus. The genera Babesia and Plasmodium are Apicomplexa hemoparasites and share features such as invasion of red blood cells (RBC. The glycoprotein Duffy is the only human erythrocyte receptor for Pasmodium vivax and a mutation which abolishes expression of this glycoprotein on erythrocyte surfaces is responsible for making the majority of people originating from the indigenous populations of West Africa resistant to P. vivax. The current work detected and quantified the Duffy antigen on Bos taurus indicus and Bos taurus taurus erythrocyte surfaces using a polyclonal antibody in order to investigate if differences in susceptibility to Babesia are due to different levels of Duffy antigen expression on the RBCs of these animals, as is known to be the case in human beings for interactions of Plasmodium vivax-Duffy antigen. ELISA tests showed that the antibody that was raised against Duffy antigens detected the presence of Duffy antigen in both subspecies and that the amount of this antigen on those erythrocyte membranes was similar. These results indicate that the greater resistance of B. taurus indicus to babesiosis cannot be explained by the absence or lower expression of Duffy antigen on RBC surfaces.

  3. Comparative study on stiffness properties of WOODCAST and conventional casting materials.

    Science.gov (United States)

    Pirhonen, Eija; Pärssinen, Antti; Pelto, Mika

    2013-08-01

    Plaster-of-Paris and synthetic materials (e.g. fibreglass) have been in clinical use as casting materials for decades. An innovative casting material, WOODCAST, brings interesting alternatives to the traditional materials. The aim of this study was to compare the stiffness properties of the WOODCAST material to traditional casting materials. In immobilization by casting, materials with variable stiffness properties are required. Ring stiffness of cylindrical samples correlates well with cast rigidity. For load-bearing structures, the use of the WOODCAST Splint is recommended as equally high stiffness was obtained with the WOODCAST Splint as was with fibreglass. The WOODCAST 2 mm product is optimal for structures where some elasticity is required, and WOODCAST Ribbon can be used in any WOODCAST structure where further reinforcement is needed. The results show that WOODCAST material can be used in replacing traditional casting materials used in extremity immobilization. The mechanical properties of casting material play an important role in safe and effective fracture immobilization. Stiffness properties of the WOODCAST casting material and conventional materials - fibreglass and plaster-of-Paris - were analysed in this study. The WOODCAST Splint appears to compare favorably with traditional materials such as Scotchcast.

  4. Inheritance and performance of the stiff-strawed mutant in Vicia faba L

    International Nuclear Information System (INIS)

    Frauen, M.; Sass, O.

    1990-01-01

    Full text: The tall and leafy types are considered to produce more vegetative mass than is necessary for high grain yield. A mutant with stunted growth, smaller leaves with dark green colour, and a stiff stem showing excellent lodging resistance, found special interest among breeders. This stiff-stem growth-type was selected as a spontaneous mutation in a breeding population. A stiff-stem line was crossed with the varieties 'Alfred' and 'Minica'. The stiff-stem recombinants showed a 20% shorter plant height, excellent lodging resistance, higher harvest index and a promise of 30% yield increase. The monogenic inheritance of the mutant trait is an advantage for further breeding work. We propose the symbol st for the new allele. (author)

  5. Controlling cyclic stiffness of a foundation, by manipulating the deformation history

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    2018-01-01

    Offshore wind turbines are slender structures, dynamic response of which depends on foundation stiffness. Unfortunately, foundations embedded in sand can become disturbed, their stiffness can increase and decrease episodically. To investigate the phenomenon governing loss and recovery of stiffnes...

  6. Contact stiffness considerations when simulating tyre/road noise

    Science.gov (United States)

    Winroth, Julia; Kropp, Wolfgang; Hoever, Carsten; Höstmad, Patrik

    2017-11-01

    Tyre/road simulation tools that can capture tyre vibrations, rolling resistance and noise generation are useful for understanding the complex processes that are involved and thereby promoting further development and optimisation. The most detailed tyre/road contact models use a spatial discretisation of the contact and assume an interfacial stiffness to account for the small-scale roughness within the elements. This interfacial stiffness has been found to have a significant impact on the simulated noise emissions but no thorough investigations of this sensitivity have been conducted. Three mechanisms are thought to be involved: The horn effect, the modal composition of the vibrational field of the tyre and the contact forces exciting the tyre vibrations. This study used a numerical tyre/road noise simulation tool based on physical relations to investigate these aspects. The model includes a detailed time-domain contact model with linear or non-linear contact springs that accounts for the effect of local tread deformation on smaller length scales. Results confirm that an increase in contact spring stiffness causes a significant increase of the simulated tyre/road noise. This is primarily caused by a corresponding increase in the contact forces, resulting in larger vibrational amplitudes. The horn effect and the modal composition are relatively unaffected and have minor effects on the radiated noise. A more detailed non-linear contact spring formulation with lower stiffness at small indentations results in a reduced high-frequency content in the contact forces and the simulated noise.

  7. Force and stiffness characteristics of superconducting bearing prototype

    International Nuclear Information System (INIS)

    Matveev, V.; Nizhelskiy, N.; Poluschenko, O.

    2004-01-01

    The radial-axial superconducting bearing prototype was designed, fabricated and tested. The YBaCuO high-temperature superconducting (HTS) monodomain disks diameter 28 mm and thickness of h = 4; 6; 8; 10 mm, capable to trap magnetic field 1 T, were fabricated to be employed in bearing prototype. Force interaction of single field cooled HTS disks with NdFeB magnets depending on disk thickness under 1 mm magnet air gap was studied. It was found that the increase in disk thickness results in reducing radial stiffness and in growing axial one. The results obtained were used for optimization of HTS-PM arrangement, and for developing the bearing design. The designed bearing incorporates a rotor with 7 HTS disks of 4 mm thickness, total mass 90 g, and stator with two pairs of permanent annular magnets of NdFeB. It is established that the force-displacement dependencies of the bearing have three zones: non-hysteresis (elastic) zone with high stiffness up to 560 N/mm; zone of elastic interaction with stiffness 190 N/mm; hysteretic zone with stiffness 150 N/mm in which a rotor residual displacement being observed after unloading. The outer bearing diameter is 130 mm, thickness 30 mm, and mass 1.8 kg. The maximal radial load capacity of the bearing is 190 N at the rotor displacement of 1.3 mm, and the maximal axial load capacity is 85 N at the displacement of 1 mm

  8. Measurements of the weak bonding interfacial stiffness by using air-coupled ultrasound

    Directory of Open Access Journals (Sweden)

    Wen-Lin Wu

    2017-12-01

    Full Text Available An air-coupled ultrasonic method, focusing on the problem that weak bonding interface is difficult to accurately measure using conventional nondestructive testing technique, is proposed to evaluate the bond integrity. Based on the spring model and the potential function theory, a theoretical model is established to predict the through-transmission spectrum in double-layer adhesive structure. The result of a theoretical algorithm shows that all the resonant transmission peaks move towards higher frequency with the increase of the interfacial stiffness. The reason for these movements is related to either the normal stiffness (KN or the transverse stiffness (KT. A method to optimize the measurement parameters (i.e. the incident angle and testing frequency is put forward through analyzing the relationship between the resonant transmission peaks and the interfacial spring stiffness at the frequency below 1MHz. The air-coupled ultrasonic testing experiments at the normal and oblique incident angle respectively are carried out to verify the theoretical analysis and to accurately measure the interfacial stiffness of double-layer adhesive composite plate. The experimental results are good agreement with the results from the theoretical algorithm, and the relationship between bonding time and interfacial stiffness is presented at the end of this paper.

  9. Shoe midsole longitudinal bending stiffness and running economy, joint energy, and EMG.

    Science.gov (United States)

    Roy, Jean-Pierre R; Stefanyshyn, Darren J

    2006-03-01

    It has been shown that mechanical energy is dissipated at the metatarsophalangeal (MTP) joint during running and jumping. Furthermore, increasing the longitudinal bending stiffness of the midsole significantly reduced the energy dissipated at the MTP joint and increased jump performance. It was hypothesized that increasing midsole longitudinal bending stiffness would also lead to improvements in running economy. This study investigated the influence of midsole longitudinal bending stiffness on running economy (performance variable) and evaluated the local effects on joint energetics and muscular activity. Carbon fiber plates were inserted into running shoe midsoles and running economy, joint energy, and electromyographic (EMG) data were collected on 13 subjects. Approximately a 1% metabolic energy savings was observed when subjects ran in a stiff midsole relative to the control midsole. Subjects with a greater body mass had a greater decrease in oxygen consumption rates in the stiff midsole relative to the control midsole condition. The stiffer midsoles showed no significant differences in energy absorption at the MTP joint compared with the control shoe. Finally, no significant changes were observed in muscular activation. Increasing midsole longitudinal bending stiffness led to improvements in running economy, yet the underlying mechanisms that can be attributed to this improvement are still not fully understood.

  10. Three new models for evaluation of standard involute spur gear mesh stiffness

    Science.gov (United States)

    Liang, Xihui; Zhang, Hongsheng; Zuo, Ming J.; Qin, Yong

    2018-02-01

    Time-varying mesh stiffness is one of the main internal excitation sources of gear dynamics. Accurate evaluation of gear mesh stiffness is crucial for gear dynamic analysis. This study is devoted to developing new models for spur gear mesh stiffness evaluation. Three models are proposed. The proposed model 1 can give very accurate mesh stiffness result but the gear bore surface must be assumed to be rigid. Enlighted by the proposed model 1, our research discovers that the angular deflection pattern of the gear bore surface of a pair of meshing gears under a constant torque basically follows a cosine curve. Based on this finding, two other models are proposed. The proposed model 2 evaluates gear mesh stiffness by using angular deflections at different circumferential angles of an end surface circle of the gear bore. The proposed model 3 requires using only the angular deflection at an arbitrary circumferential angle of an end surface circle of the gear bore but this model can only be used for a gear with the same tooth profile among all teeth. The proposed models are accurate in gear mesh stiffness evaluation and easy to use. Finite element analysis is used to validate the accuracy of the proposed models.

  11. Use of rbcL and trnL-F as a two-locus DNA barcode for identification of NW-European ferns: an ecological perspective

    NARCIS (Netherlands)

    Groot, de G.A.; During, H.J.; Maas, J.W.; Schneider, H.; Erkens, R.H.J.

    2011-01-01

    Although consensus has now been reached on a general two-locus DNA barcode for land plants, the selected combination of markers (rbcL + matK) is not applicable for ferns at the moment. Yet especially for ferns, DNA barcoding is potentially of great value since fern gametophytes—while playing an

  12. Biological augmentation of rotator cuff repair using bFGF-loaded electrospun poly(lactide-co-glycolide fibrous membranes

    Directory of Open Access Journals (Sweden)

    Zhao S

    2014-05-01

    Full Text Available Song Zhao,1,* Jingwen Zhao,3,* Shikui Dong,1 Xiaoqiao Huangfu,1 Bin Li,2,3 Huilin Yang,2,3 Jinzhong Zhao,1 Wenguo Cui2,31Department of Arthroscopic Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 2Orthopedic Institute, Soochow University, Suzhou, Jiangsu, 3Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, People's Republic of China *These authors contributed equally to this work Abstract: Clinically, rotator cuff tear (RCT is among the most common shoulder pathologies. Despite significant advances in surgical techniques, the re-tear rate after rotator cuff (RC repair remains high. Insufficient healing capacity is likely the main factor for reconstruction failure. This study reports on a basic fibroblast growth factor (bFGF-loaded electrospun poly(lactide-co-glycolide (PLGA fibrous membrane for repairing RCT. Implantable biodegradable bFGF–PLGA fibrous membranes were successfully fabricated using emulsion electrospinning technology and then characterized and evaluated with in vitro and in vivo cell proliferation assays and repairs of rat chronic RCTs. Emulsion electrospinning fabricated ultrafine fibers with a core-sheath structure which secured the bioactivity of bFGF in a sustained manner for 3 weeks. Histological observations showed that electrospun fibrous membranes have excellent biocompatibility and biodegradability. At 2, 4, and 8 weeks after in vivo RCT repair surgery, electrospun fibrous membranes significantly increased the area of glycosaminoglycan staining at the tendon–bone interface compared with the control group, and bFGF–PLGA significantly improved collagen organization, as measured by birefringence under polarized light at the healing enthesis compared with the control and PLGA groups. Biomechanical testing showed that the electrospun fibrous membrane groups had a greater ultimate load-to-failure and stiffness than the control group at 4

  13. Influence of iron deficiency in the radiopharmaceutical behavior of red blood cells labeled with 99mTc(99mTC-RBC)

    International Nuclear Information System (INIS)

    Calmanovici, G.; Salgueiro, M.J.; Pernas, L.; Collia, N.; Leonardi, N.; Zubillaga, M.

    2005-01-01

    Full text: Red blood cells (RBCs) labeled with 99m Tc are commonly used in the evaluation of cardiac function, gastrointestinal tract bleeding, red blood cell volume or splenic sequestration. Generally stannous ion is used as reducing agent. A proposed mechanism is that once the stannous ion (Sn) and the pertechnetate ( 99m Tc) reach the interior of the RBC, the radionuclide is mainly house in the β-chain of hemoglobin. The aim of this study was to determine if hemoglobin content reduction, an indicator of iron deficiency anemia, could affect the efficiency of RBC labeling and the biological distribution of this radiopharmaceutical. We studied 30 rats fed for 3 weeks after weaning with diets with iron contents of 6.5 ppm (group A), 18 ppm (group B) and 100 ppm (control). For all groups, the labeling yields were always higher than 97%; the percentage of radioactivity was mostly founded in blood with almost negligible radioactivity the rest of the studied organs. We can conclude that the decrease in hemoglobin content, an indicator of iron deficiency anemia, does not interfere neither in the labeling nor in the biodistribution of red blood cells labeled with 99m Tc. (author)

  14. Artificial neural networks for stiffness estimation in magnetic resonance elastography.

    Science.gov (United States)

    Murphy, Matthew C; Manduca, Armando; Trzasko, Joshua D; Glaser, Kevin J; Huston, John; Ehman, Richard L

    2018-07-01

    To investigate the feasibility of using artificial neural networks to estimate stiffness from MR elastography (MRE) data. Artificial neural networks were fit using model-based training patterns to estimate stiffness from images of displacement using a patch size of ∼1 cm in each dimension. These neural network inversions (NNIs) were then evaluated in a set of simulation experiments designed to investigate the effects of wave interference and noise on NNI accuracy. NNI was also tested in vivo, comparing NNI results against currently used methods. In 4 simulation experiments, NNI performed as well or better than direct inversion (DI) for predicting the known stiffness of the data. Summary NNI results were also shown to be significantly correlated with DI results in the liver (R 2  = 0.974) and in the brain (R 2  = 0.915), and also correlated with established biological effects including fibrosis stage in the liver and age in the brain. Finally, repeatability error was lower in the brain using NNI compared to DI, and voxel-wise modeling using NNI stiffness maps detected larger effects than using DI maps with similar levels of smoothing. Artificial neural networks represent a new approach to inversion of MRE data. Summary results from NNI and DI are highly correlated and both are capable of detecting biologically relevant signals. Preliminary evidence suggests that NNI stiffness estimates may be more resistant to noise than an algebraic DI approach. Taken together, these results merit future investigation into NNIs to improve the estimation of stiffness in small regions. Magn Reson Med 80:351-360, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Integración por cuantificación de sistemas stiff

    Directory of Open Access Journals (Sweden)

    Gustavo Migoni

    2007-07-01

    Full Text Available Resumen: Este artículo presenta un nuevo método de integración numérica de ecuaciones diferenciales ordinarias basado en la cuantificación de las variables de estado. Utilizando conceptos de integración implícita, el nuevo método denominado BQSS (Backward Quantized State Systems permite integrar sistemas stiff de manera eficiente. Siendo el primer método de cuantificación para sistemas stiff, BQSS es en sí un método explícito, por lo que la contribución es importante en el contexto general de los métodos de integración numérica. Además de presentar el método, el artículo estudia las principales propiedades teóricas del mismo, aborda aspectos prácticos de la implementación del algoritmo y presenta resultados de simulación sobre dos sistemas stiff. Palabras clave: Métodos de Integración Numérica, Sistemas Stiff, Integración por Cuantificación

  16. Stiff person case misdiagnosed as conversion disorder: A case report.

    Science.gov (United States)

    Razmeh, Saeed; Habibi, Amir Hasan; Sina, Farzad; Alizadeh, Elham; Eslami, Monireh

    2017-01-01

    Stiff person syndrome (SPS) is a rare neurological disease resulting in stiffness and spasm of muscles. It initially affects the axial muscles and then spread to limb muscles. Emotional stress exacerbated the symptoms and signs of the disease. The pathophysiology of the disease is caused by the decreased level of the glutamic acid decarboxylase (GAD) activity due to an autoantibody against GAD that decreases the level of gamma-aminobutyric acid (GABA). In this paper, we present a case of atypical presentation of SPS with lower limb stiffness misdiagnosed as conversion disorder. We report a patient with atypical presentation of SPS with lower limb stiffness and gait disorder misdiagnosed as conversion disorder for a year. Her antithyroid peroxidase antibody (anti-TPO Ab) level was 75 IU (normal value: 0-34 IU). Intravenous immunoglobulin (IVIG) was administered (2gr/kg, 5 days) for the patient that showed significant improvement in the follow-up visit. It is essential that in any patient with bizarre gait disorder and suspicious to conversion disorder due to the reversibility of symptoms, SPS and other movement disorder should be considered.

  17. Comparative numerical solutions of stiff Ordinary differential equations using magnus series expansion method

    Directory of Open Access Journals (Sweden)

    SURE KÖME

    2014-12-01

    Full Text Available In this paper, we investigated the effect of Magnus Series Expansion Method on homogeneous stiff ordinary differential equations with different stiffness ratios. A Magnus type integrator is used to obtain numerical solutions of two different examples of stiff problems and exact and approximate results are tabulated. Furthermore, absolute error graphics are demonstrated in detail.

  18. An EKF-based approach for estimating leg stiffness during walking.

    Science.gov (United States)

    Ochoa-Diaz, Claudia; Menegaz, Henrique M; Bó, Antônio P L; Borges, Geovany A

    2013-01-01

    The spring-like behavior is an inherent condition for human walking and running. Since leg stiffness k(leg) is a parameter that cannot be directly measured, many techniques has been proposed in order to estimate it, most of them using force data. This paper intends to address this problem using an Extended Kalman Filter (EKF) based on the Spring-Loaded Inverted Pendulum (SLIP) model. The formulation of the filter only uses as measurement information the Center of Mass (CoM) position and velocity, no a priori information about the stiffness value is known. From simulation results, it is shown that the EKF-based approach can generate a reliable stiffness estimation for walking.

  19. Influence of inhaled nicotine source on arterial stiffness.

    Science.gov (United States)

    Szołtysek-Bołdys, Izabela; Sobczak, Andrzej; Zielińska-Danch, Wioleta; Bartoń, Aleksandra; Koszowski, Bartosz; Kośmider, Leon

    2014-01-01

    Tobacco smoking leads to changes in hemodynamic parameters such as heart rate and systolic or diastolic blood pressure. It has a direct influence on the elasticity of blood vessels and increases arterial stiffness, which can result in development of atherosclerosis. Data show that the nicotine in tobacco smoke probably is responsible for these changes. Electronic cigarettes (e-cigarettes) were supposedly a healthier alternative to combustible cigarettes because they imitate a process of cigarettes smoking but generate nicotine aerosol without the toxic substances from tobacco combustion. However, the use of e-cigarettes is still controversial because their toxicity, safety and long term use health impact have not been sufficiently studied. The aim of this study was to evaluate changes in arterial stiffness parameters after smoking a cigarette or e-cigarette use. Fifteen healthy women, aged 19-25 years old, smoking ≥5 cigarettes per day for at least two years participated in the study. A non-invasive measurement of arterial stiffness parameters - Stiffness Index (SI) and Reflection Index (RI) - was conducted and systolic and diastolic blood pressure and heart rate were measured before and after smoking a conventional cigarette as well as use of an e-cigarette. Statistically significant changes in the SI and RI were observed before and after smoking of a conventional cigarette [SI: 6.75m/s (6.66 - 6.85, 95% CI) vs 6.56m/s (6.46 - 6.65. 95% CI), p=0.0056; RI: 54.0% (51.5 - 56.7, 95% CI) vs 49.6% (47.5 - 51.8, 95% CI), p=0.010]. The use of e-cigarettes resulted in no statistically significant changes in the SI and RI. After both product use systolic and diastolic blood pressure and heart rate increased but the changes were not statistically significant. In contrast to conventional cigarette use, the use of electronic cigarettes causes no changes in arterial stiffness. This may indicate lower bioavailability of nicotine from the e-cigarette or an additional effect of

  20. Physical degradation of membrane electrode assemblies undergoing freeze/thaw cycling: Micro-structure effects

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. [Fuel Cell Dynamics and Diagnostics Laboratory, Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 (United States); Research and Development Division, Hyundai Motor Company, Yongin 446-912 (Korea); Mench, M.M. [Fuel Cell Dynamics and Diagnostics Laboratory, Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 (United States)

    2007-11-22

    The objective of this work is to investigate physical damage of polymer electrolyte fuel cell (PEFC) materials subjected to freeze/thaw cycling. Effects of membrane electrode assembly micro-structures (catalyst layer cracking, membrane thickness, and membrane reinforcement) and diffusion media with micro-porous layers were analyzed by comparing scanning electron microscopy images of freeze/thaw cycled samples (-40 C/70 C) with those of virgin material and thermal cycled samples without freezing (5 C/70 C). Ex situ testing performed in this study has revealed a strong direction for the material choices in the PEFC and confirmed the previous computational model in the literature [S. He, M.M. Mench, J. Electrochem. Soc., 153 (2006) A1724-A1731; S. He, S.H. Kim, M.M. Mench, J. Electrochem. Soc., in press]. Specifically, the membrane electrode assemblies were found to be a source of water that can damage the catalyst layers under freeze/thaw conditions. Damage was found to occur almost exclusively under the channel, and not under the land (the graphite that touches the diffusion media). Conceptually, the best material to mitigate freeze-damage is a crack free virgin catalyst layer on a reinforced membrane that is as thin as possible, protected by a stiff diffusion media. (author)

  1. Computational local stiffness analysis of biological cell: High aspect ratio single wall carbon nanotube tip

    Energy Technology Data Exchange (ETDEWEB)

    TermehYousefi, Amin, E-mail: at.tyousefi@gmail.com [Department of Human Intelligence Systems, Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology (Kyutech) (Japan); Bagheri, Samira; Shahnazar, Sheida [Nanotechnology & Catalysis Research Centre (NANOCAT), IPS Building, University Malaya, 50603 Kuala Lumpur (Malaysia); Rahman, Md. Habibur [Department of Computer Science and Engineering, University of Asia Pacific, Green Road, Dhaka-1215 (Bangladesh); Kadri, Nahrizul Adib [Department of Biomedical Engineering, Faculty of Engineering, University Malaya, 50603 Kuala Lumpur (Malaysia)

    2016-02-01

    Carbon nanotubes (CNTs) are potentially ideal tips for atomic force microscopy (AFM) due to the robust mechanical properties, nanoscale diameter and also their ability to be functionalized by chemical and biological components at the tip ends. This contribution develops the idea of using CNTs as an AFM tip in computational analysis of the biological cells. The proposed software was ABAQUS 6.13 CAE/CEL provided by Dassault Systems, which is a powerful finite element (FE) tool to perform the numerical analysis and visualize the interactions between proposed tip and membrane of the cell. Finite element analysis employed for each section and displacement of the nodes located in the contact area was monitored by using an output database (ODB). Mooney–Rivlin hyperelastic model of the cell allows the simulation to obtain a new method for estimating the stiffness and spring constant of the cell. Stress and strain curve indicates the yield stress point which defines as a vertical stress and plan stress. Spring constant of the cell and the local stiffness was measured as well as the applied force of CNT-AFM tip on the contact area of the cell. This reliable integration of CNT-AFM tip process provides a new class of high performance nanoprobes for single biological cell analysis. - Graphical abstract: This contribution develops the idea of using CNTs as an AFM tip in computational analysis of the biological cells. The proposed software was ABAQUS 6.13 CAE/CEL provided by Dassault Systems. Finite element analysis employed for each section and displacement of the nodes located in the contact area was monitored by using an output database (ODB). Mooney–Rivlin hyperelastic model of the cell allows the simulation to obtain a new method for estimating the stiffness and spring constant of the cell. Stress and strain curve indicates the yield stress point which defines as a vertical stress and plan stress. Spring constant of the cell and the local stiffness was measured as well

  2. Mechanically stiff, electrically conductive composites of polymers and carbon nanotubes

    Science.gov (United States)

    Worsley, Marcus A.; Kucheyev, Sergei O.; Baumann, Theodore F.; Kuntz, Joshua D.; Satcher, Jr., Joe H.; Hamza, Alex V.

    2015-07-21

    Using SWNT-CA as scaffolds to fabricate stiff, highly conductive polymer (PDMS) composites. The SWNT-CA is immersing in a polymer resin to produce a SWNT-CA infiltrated with a polymer resin. The SWNT-CA infiltrated with a polymer resin is cured to produce the stiff and electrically conductive composite of carbon nanotube aerogel and polymer.

  3. Mechanically stiff, electrically conductive composites of polymers and carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Worsley, Marcus A.; Kucheyev, Sergei O.; Baumann, Theodore F.; Kuntz, Joshua D.; Satcher, Jr., Joe H.; Hamza, Alex V.

    2017-10-17

    Using SWNT-CA as scaffolds to fabricate stiff, highly conductive polymer (PDMS) composites. The SWNT-CA is immersing in a polymer resin to produce a SWNT-CA infiltrated with a polymer resin. The SWNT-CA infiltrated with a polymer resin is cured to produce the stiff and electrically conductive composite of carbon nanotube aerogel and polymer.

  4. Current front stiffness of European vehicles with regard to compatibility

    NARCIS (Netherlands)

    Huibers, J.; Beer, E. de

    2001-01-01

    EuroNCAP tests are carried out since 1997. The test procedure in general is comparable to the EC Directive 96/79 with a test speed of 64 km/h. This increased test speed implies a higher frontal stiffness for new vehicle designs in order to achieve a high ranking. This frontal stiffness is one of the

  5. Application of force-length curve for determination of leg stiffness during a vertical jump.

    Science.gov (United States)

    Struzik, Artur; Zawadzki, Jerzy

    2016-01-01

    The aim of this study was to present the methodology for estimation of a leg stiffness during a countermovement jump. The question was asked whether leg stiffness in the countermovement and take-off phases are similar to each other as demonstrated in previous reports. It was also examined whether the stiffness in left lower limb is similar to the one in right lower limb. The research was conducted on 35 basketball players. Each participant performed three countermovement jumps with arm swing to the maximum height. Measurements employed a Kistlerforce plate and a BTS SMART system for motion analysis. Leg stiffness (understood as an inclination of the curve of ground reaction forces vs. length) was computed for these parts of countermovement and take-off phases where its value was relatively constant and F(Δl) relationship was similar to linear. Mean value (±SD) of total stiffness of both lower limbs in the countermovement phase was 7.1 ± 2.3 kN/m, whereas this value in the take-off phase was 7.5 ± 1 kN/m. No statistically significant differences were found between the leg stiffness in the countermovement and the take-off phases. No statistically significant differences were found during the comparison of the stiffness in the right and left lower limb. The calculation methodology allows us to estimate the value of leg stiffness based on the actual shape of F(Δl) curve rather than on extreme values of ΔF and Δl. Despite different tasks of the countermovement and the take-off phases, leg stiffness in these phases is very similar. Leg stiffness during a single vertical jump maintains a relatively constant value in the parts with a small value of acceleration.

  6. Matrix stiffness reverses the effect of actomyosin tension on cell proliferation.

    Science.gov (United States)

    Mih, Justin D; Marinkovic, Aleksandar; Liu, Fei; Sharif, Asma S; Tschumperlin, Daniel J

    2012-12-15

    The stiffness of the extracellular matrix exerts powerful effects on cell proliferation and differentiation, but the mechanisms transducing matrix stiffness into cellular fate decisions remain poorly understood. Two widely reported responses to matrix stiffening are increases in actomyosin contractility and cell proliferation. To delineate their relationship, we modulated cytoskeletal tension in cells grown across a physiological range of matrix stiffnesses. On both synthetic and naturally derived soft matrices, and across a panel of cell types, we observed a striking reversal of the effect of inhibiting actomyosin contractility, switching from the attenuation of proliferation on rigid substrates to the robust promotion of proliferation on soft matrices. Inhibiting contractility on soft matrices decoupled proliferation from cytoskeletal tension and focal adhesion organization, but not from cell spread area. Our results demonstrate that matrix stiffness and actomyosin contractility converge on cell spreading in an unexpected fashion to control a key aspect of cell fate.

  7. Static and dynamic light scattering by red blood cells: A numerical study.

    Science.gov (United States)

    Mauer, Johannes; Peltomäki, Matti; Poblete, Simón; Gompper, Gerhard; Fedosov, Dmitry A

    2017-01-01

    Light scattering is a well-established experimental technique, which gains more and more popularity in the biological field because it offers the means for non-invasive imaging and detection. However, the interpretation of light-scattering signals remains challenging due to the complexity of most biological systems. Here, we investigate static and dynamic scattering properties of red blood cells (RBCs) using two mesoscopic hydrodynamics simulation methods-multi-particle collision dynamics and dissipative particle dynamics. Light scattering is studied for various membrane shear elasticities, bending rigidities, and RBC shapes (e.g., biconcave and stomatocyte). Simulation results from the two simulation methods show good agreement, and demonstrate that the static light scattering of a diffusing RBC is not very sensitive to the changes in membrane properties and moderate alterations in cell shapes. We also compute dynamic light scattering of a diffusing RBC, from which dynamic properties of RBCs such as diffusion coefficients can be accessed. In contrast to static light scattering, the dynamic measurements can be employed to differentiate between the biconcave and stomatocytic RBC shapes and generally allow the differentiation based on the membrane properties. Our simulation results can be used for better understanding of light scattering by RBCs and the development of new non-invasive methods for blood-flow monitoring.

  8. Impact of morning stiffness on working behaviour and performance in people with rheumatoid arthritis.

    Science.gov (United States)

    Mattila, Kalle; Buttgereit, Frank; Tuominen, Risto

    2014-12-01

    Work disability remains a considerable problem for many patients with rheumatoid arthritis (RA). Morning stiffness is a symptom of RA associated with early retirement from work and with impaired functional ability. We aimed to explore the patient's perception of the impact of morning stiffness on the working life of patients with RA. A survey was conducted in 11 European countries. Patients of working age, with RA for ≥6 months and morning stiffness ≥3 mornings a week, were interviewed by telephone using a structured questionnaire. Responses were assessed in the total sample and in subgroups defined by severity and duration of morning stiffness and by country. A total of 1,061 respondents completed the survey, 534 were working, 224 were retired and the rest were, i.e. homemakers and unemployed. Among the 534 working respondents, RA-related morning stiffness affected work performance (47 %), resulted in late arrival at work (33 %) and required sick leave in the past month (15 %). Of the 224 retired respondents, 159 (71 %) stopped working earlier than their expected retirement age, with 64 % giving RA-related morning stiffness as a reason. There was a differential impact of increasing severity and increasing duration of morning stiffness on the various parameters studied. There were notable inter-country differences in the impact of RA-related morning stiffness on ability to work and on retirement. This large survey showed that from the patient's perspective, morning stiffness reduces the ability to work in patients with RA and contributes to early retirement.

  9. Effect of chain stiffness on the structure of single-chain polymer nanoparticles

    DEFF Research Database (Denmark)

    Moreno, Angel J; Bacova, Petra; Lo Verso, Federica

    2018-01-01

    of the domains is in all cases similar to that of Gaussian chains or rings, irrespective of the stiffness and degree of cross-linking. It is the spatial arrangement of the domains which determines the global structure of the SCNP (sparse Gaussian-like object or crumpled globule). Since intramolecular stiffness...... or 'crumpled' globular behaviour for very stiff SCNPs. We characterize domains in the SCNPs. These are weakly deformable regions that can be seen as disordered analogues of domains in disordered proteins. Increasing stiffness leads to bigger and less deformable domains. Surprisingly, the scaling behaviour...... can be varied through the specific chemistry of the precursor or by introducing bulky side groups in its backbone, our results propose a new strategy to tune the global structure of SCNPs. ....

  10. On the influence of the foundation stiffness in the structural dynamic response

    International Nuclear Information System (INIS)

    Halbritter, A.L.; Koishi, N.; Stukart, R.N.L.

    1984-01-01

    To consider the influence of the foundation on the structural dynamic analysis, it is usual to represent the foundation stiffness by springs and the damping by snubbers, in the structural model. The stiffness and the damping values of the foundation can be determined by approximate methods based on simplifying assumptions, using, for example, the formula derived from the half space theory or numerical methods. The foundation stiffness has a great influence on the dynamic characteristics of the structure (eigenvalues and eigenvectors), and together with the damping influence the structural dynamic response. In this paper the influence of the foundation stiffness on the floor response spectra of the reactor building of a NPP of 1300 MW PWR of KWU type is studied. (Author) [pt

  11. Gait Selection and Transition of Passivity-Based Bipeds with Adaptable Ankle Stiffness

    Directory of Open Access Journals (Sweden)

    Yan Huang

    2012-10-01

    Full Text Available Stable bipedal walking is one of the most important components of humanoid robot design, which can help us better understand natural human walking. In this paper, to study gait selection and gait transition of efficient bipedal walking, we proposed a dynamic bipedal walking model with an upper body, flat feet and compliant joints. The model can achieve stable cyclic motion with different walking gaits. The hip actuation and ankle stiffness behavior of the model are quite similar to those of human normal walking. In simulation, we studied the influence of hip actuation and ankle stiffness on walking performance of each gait. The effects of ankle stiffness on gait selection are also analyzed. Gait transition is realized by adjusting ankle stiffness during walking.

  12. Assessment of impact factors on shear wave based liver stiffness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Wenwu, E-mail: lingwenwubing@163.com [Department of Ultrasound, West China Hospital of Sichuan University, Chengdu 610041 (China); Lu, Qiang, E-mail: wsluqiang@126.com [Department of Ultrasound, West China Hospital of Sichuan University, Chengdu 610041 (China); Quan, Jierong, E-mail: quanjierong@163.com [Department of Ultrasound, West China Hospital of Sichuan University, Chengdu 610041 (China); Ma, Lin, E-mail: malin2010US@163.com [Department of Ultrasound, West China Hospital of Sichuan University, Chengdu 610041 (China); Luo, Yan, E-mail: huaxiluoyan@gmail.com [Department of Ultrasound, West China Hospital of Sichuan University, Chengdu 610041 (China)

    2013-02-15

    Shear wave based ultrasound elastographies have been implemented as non-invasive methods for quantitative assessment of liver stiffness. Nonetheless, there are only a few studies that have investigated impact factors on liver stiffness measurement (LSM). Moreover, standard examination protocols for LSM are still lacking in clinical practice. Our study aimed to assess the impact factors on LSM to establish its standard examination protocols in clinical practice. We applied shear wave based elastography point quantification (ElastPQ) in 21 healthy individuals to determine the impact of liver location (segments I–VIII), breathing phase (end-inspiration and end-expiration), probe position (sub-costal and inter-costal position) and examiner on LSM. Additional studies in 175 healthy individuals were also performed to determine the influence of gender and age on liver stiffness. We found significant impact of liver location on LSM, while the liver segment V displayed the lowest coefficient of variation (CV 21%). The liver stiffness at the end-expiration was significantly higher than that at the end-inspiration (P = 2.1E−05). The liver stiffness was 8% higher in men than in women (3.8 ± 0.7 kPa vs. 3.5 ± 0.4 kPa, P = 0.0168). In contrast, the liver stiffness was comparable in the different probe positions, examiners and age groups (P > 0.05). In conclusion, this study reveals significant impact from liver location, breathing phase and gender on LSM, while furthermore strengthening the necessity for the development of standard examination protocols on LSM.

  13. Effect of Oral Docosahexaenoic Acid (DHA) Supplementation on DHA Levels and Omega-3 Index in Red Blood Cell Membranes of Breast Cancer Patients.

    Science.gov (United States)

    Molfino, Alessio; Amabile, Maria I; Mazzucco, Sara; Biolo, Gianni; Farcomeni, Alessio; Ramaccini, Cesarina; Antonaroli, Simonetta; Monti, Massimo; Muscaritoli, Maurizio

    2017-01-01

    Rationale: Docosahexaenoic acid (DHA) in cell membrane may influence breast cancer (BC) patients' prognosis, affecting tumor cells sensitivity to chemo- and radio-therapy and likely modulating inflammation. The possibility of identifying BC patients presenting with low DHA levels and/or low ability of DHA incorporation into cell membrane might help to treat this condition. Methods: We enrolled BC patients and healthy controls, recording their seafood dietary intake. DHA in form of algal oil was administered for 10 consecutive days (2 g/day). Blood samples were collected at baseline (T0) and after 10 days of supplementation (T1) to assess DHA, omega-3 index, as the sum of DHA + eicosapentaenoic acid (EPA), in red blood cells (RBC) membranes and plasma tumor necrosis factor-alpha and interleukin-6 levels. Pre- and post-treatment fatty acid profiles were obtained by gas-chromatography. Parametric and non-parametric tests were performed, as appropriate, and P -value DHA and omega-3 index increased from T0 to T1 in the 3 groups of BC patients and in controls ( P DHA incorporation between each group of BC patients and between patients and controls, except for M group, which incorporated higher DHA levels with respect to controls (β = 0.42; P = 0.03). No association was documented between cytokines levels and DHA and omega-3 index at baseline and after DHA supplementation. Independent of the presence of BC, women considered as "good seafood consumers" showed at baseline DHA and omega-3 index higher with respect to "low seafood consumers" ( P = 0.04; P = 0.007, respectively). After supplementation, the increase in DHA levels was greater in "low seafood consumers" with respect to "good seafood consumers" ( P DHA supplementation was associated with increased DHA levels and omega-3 index in RBC membranes of BC cancer patients, independent of the type of BC presentation, and in controls. BRCA1/2 mutation, as well as low seafood consuming habits in both BC patients and healthy

  14. A mechanism to compensate undesired stiffness in joints of prosthetic hands

    NARCIS (Netherlands)

    Smit, G.; Plettenbrug, D.H.; Van der Helm, F.C.T.

    2014-01-01

    Background: Cosmetic gloves that cover a prosthetic hand have a parasitic positive stiffness that counteracts the flexion of a finger joint. Objectives: Reducing the required input torque to move a finger of a prosthetic hand by compensating the parasitic stiffness of the cosmetic glove. Study

  15. Ursodeoxycholic acid treatment is associated with improvement of liver stiffness in cystic fibrosis patients.

    Science.gov (United States)

    van der Feen, Cathelijne; van der Doef, Hubert P J; van der Ent, Cornelis K; Houwen, Roderick H J

    2016-11-01

    Ursodeoxycholic acid (UDCA) might prevent progression of cystic fibrosis liver disease, but objective parameters for its effect are lacking. We used liver stiffness measurements to evaluate the effect of Ursodeoxycholic acid. Paired measurements of liver stiffness were done in 73 patients without UDCA and in 32 patients with UDCA. In the latter group, 6 patients had cirrhosis; in 15 patients, UDCA was started based on Colombo criteria, and in 11 patients for other reasons. In patients without UDCA, liver stiffness increased: 0.19 (-0.03 to 0.59)kPa/year. Liver stiffness also increased in patients with cirrhosis: 4.6 (0.67-12.4)kPa/year. In patients who had UDCA based on Colombo criteria, a decrease of liver stiffness was observed: 0.70 (-1.6 to 0.55)kPa/year (P=0.01). In patients on UDCA for other reasons, liver stiffness increased: 0.23 (-0.20 to 0.51)kPa/year. UDCA reduced liver stiffness in patients with well-defined, mild liver disease. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  16. Attenuation of Red Blood Cell Storage Lesions with Vitamin C

    Directory of Open Access Journals (Sweden)

    Kimberly Sanford

    2017-07-01

    Full Text Available Stored red blood cells (RBCs undergo oxidative stress that induces deleterious metabolic, structural, biochemical, and molecular changes collectively referred to as “storage lesions”. We hypothesized that vitamin C (VitC, reduced or oxidized would reduce red cell storage lesions, thus prolonging their storage duration. Whole-blood-derived, leuko-reduced, SAGM (saline-adenine-glucose-mannitol-preserved RBC concentrates were equally divided into four pediatric storage bags and the following additions made: (1 saline (saline; (2 0.3 mmol/L reduced VitC (Lo VitC; (3 3 mmol/L reduced VitC (Hi VitC; or (4 0.3 mmol/L oxidized VitC (dehydroascorbic acid, DHA as final concentrations. Biochemical and rheological parameters were serially assessed at baseline (prior to supplementation and Days 7, 21, 42, and 56 for RBC VitC concentration, pH, osmotic fragility by mechanical fragility index, and percent hemolysis, LDH release, glutathione depletion, RBC membrane integrity by scanning electron microscopy, and Western blot for β-spectrin. VitC exposure (reduced and oxidized significantly increased RBC antioxidant status with varying dynamics and produced trends in reduction in osmotic fragility and increases in membrane integrity. Conclusion: VitC partially protects RBC from oxidative changes during storage. Combining VitC with other antioxidants has the potential to improve long-term storage of RBC.

  17. A new design of dielectric elastomer membrane resonator with tunable resonant frequencies and mode shapes

    Science.gov (United States)

    Li, Yunlong; Oh, Inkyu; Chen, Jiehao; Hu, Yuhang

    2018-06-01

    Conventional membrane resonators are bulky, and once the geometries and materials are fixed in the fabricated device, the resonators’ characteristics are fixed. In this work, we introduce the active membrane, dielectric elastomer (DE), into the resonator design. Attaching a stiffer passive membrane onto the active DE membrane forms a two-layer system, which generates an out-of-plane deformation when the DE is actuated through a DC voltage applied across the thickness of the DE membrane. When an AC voltage is applied, the two-layer system can generate an out-of-plane oscillation which enables its use as membrane resonators. Both experiments and simulations are carried out to study the dynamic characteristics of the system. The resonant frequencies and mode shapes of the resonator can be tuned through the passive layer properties such as the modulus, thickness, density, and size. The effective stiffness of the DE film changes as the magnitude of the voltage applied on the film changes, which provides an active way to tune the dynamic characteristics of the two-layer resonator even after the device is set. The system is also light weight, low cost, and easy to fabricate, and has great potential in many engineering applications.

  18. Mathematical Models Suggest Facilitated Fatty Acids Crossing of the Luminal Membrane in the Cardiac Muscle.

    Science.gov (United States)

    Barta, Efrath

    2017-02-01

    Long-chain fatty acids cross a few membranes on their way from the capillary blood to the cardiomyocyte cytosol, where they are utilized as an essential source of energy. Details of the transport mechanism across those membranes remained elusive despite decades of laboratory and theoretical work. Here we inspect several optional scenarios for the crossing of the luminal membrane of the endothelial cell, the first barrier that should be crossed: a passive diffusion, facilitation by receptors for albumin and facilitation by fatty acids transporters. Related measured rate constants are incorporated in a theoretical simulation that is based on reaction-diffusion equations. Asymptotic analytical solutions for the resulting stiff boundary value problems are formulated based on singular perturbations theory. We conclude that a passive diffusion has to be supplemented with facilitation mechanisms in order to meet energy requirements. Binding sites for albumin, scattered on the membrane face, might enhance the flux provided that they internalize the captured fatty acids and speed up the dissociation of the albumin-fatty acids complex. As such enhancement is moderate, another mechanism seems to be essential for an adequate supply of fatty acids. Lack of experimental data prohibits us from computing the quantitative effect of membrane fatty acids transporters but their involvement in the membrane crossing is inferred.

  19. A novel magnetorheological elastomer isolator with negative changing stiffness for vibration reduction

    International Nuclear Information System (INIS)

    Yang, J; Sun, S S; Li, W H; Alici, G; Du, H; Deng, H X

    2014-01-01

    Magneto-rheological elastomers (MREs) have attracted notable credits in the development of smart isolators and absorbers due to their controllable stiffness and damping properties. For the purpose of mitigating unwanted structural and/or machinery vibrations, the traditional MRE-based isolators have been generally proven effective because the MR effect can increase the stiffness when the magnetic field is strengthened. This study presents a novel MRE isolator that experienced reduced stiffness when the applied current was increased. This innovative work was accomplished by applying a hybrid magnet (electromagnet and permanent magnets) onto a multilayered MRE structure. To characterise this negative changing stiffness concept, a multilayered MRE isolator with a hybrid magnet was first designed, fabricated and then tested to measure its properties. An obvious reduction of the effective stiffness and natural frequency of the proposed MRE isolator occurred when the current was continuously adjusted. This device could also work as a conventional MRE isolator as its effective stiffness and natural frequency also increased when a negative current was applied. Further testing was carried out on a one-degree-of-freedom system to assess how effectively this device could isolate vibration. In this experiment, two cases were considered; in each case, the vibration of the primary system was obviously attenuated under ON-OFF control logic, thus demonstrating the feasibility of this novel design as an alternative adaptive vibration isolator. (paper)

  20. Increased Stiffness in Aged Skeletal Muscle Impairs Muscle Progenitor Cell Proliferative Activity.

    Directory of Open Access Journals (Sweden)

    Grégory Lacraz

    Full Text Available Skeletal muscle aging is associated with a decreased regenerative potential due to the loss of function of endogenous stem cells or myogenic progenitor cells (MPCs. Aged skeletal muscle is characterized by the deposition of extracellular matrix (ECM, which in turn influences the biomechanical properties of myofibers by increasing their stiffness. Since the stiffness of the MPC microenvironment directly impacts MPC function, we hypothesized that the increase in muscle stiffness that occurs with aging impairs the behavior of MPCs, ultimately leading to a decrease in regenerative potential.We showed that freshly isolated individual myofibers from aged mouse muscles contain fewer MPCs overall than myofibers from adult muscles, with fewer quiescent MPCs and more proliferative and differentiating MPCs. We observed alterations in cultured MPC behavior in aged animals, where the proliferation and differentiation of MPCs were lower and higher, respectively. These alterations were not linked to the intrinsic properties of aged myofibers, as shown by the similar values for the cumulative population-doubling values and fusion indexes. However, atomic force microscopy (AFM indentation experiments revealed a nearly 4-fold increase in the stiffness of the MPC microenvironment. We further showed that the increase in stiffness is associated with alterations to muscle ECM, including the accumulation of collagen, which was correlated with higher hydroxyproline and advanced glycation end-product content. Lastly, we recapitulated the impaired MPC behavior observed in aging using a hydrogel substrate that mimics the stiffness of myofibers.These findings provide novel evidence that the low regenerative potential of aged skeletal muscle is independent of intrinsic MPC properties but is related to the increase in the stiffness of the MPC microenvironment.

  1. Arterial Stiffness and Functional Outcome in Acute Ischemic Stroke

    OpenAIRE

    Lee, Yeong-Bae; Park, Joo-Hwan; Kim, Eunja; Kang, Chang-Ki; Park, Hyeon-Mi

    2014-01-01

    Objective Arterial stiffness is a common change associated with aging and can be evaluated by measuring pulse wave velocity (PWV) between sites in the arterial tree, with the stiffer artery having the higher PWV. Arterial stiffness is associated with the risk of stroke in the general population and of fatal stroke in hypertensive patients. This study is to clarify whether PWV value predicts functional outcome of acute ischemic stroke. Methods One hundred patients were enrolled with a diagnosi...

  2. Experimental challenges to stiffness as a transport paradigm

    Science.gov (United States)

    Luce, T. C.; Burrell, K. H.; Holland, C.; Marinoni, A.; Petty, C. C.; Smith, S. P.; Austin, M. E.; Grierson, B. A.; Zeng, L.

    2018-02-01

    Two power scans were carried out in H-mode plasmas in DIII-D; one employed standard co-current neutral beam injection (NBI), while the other used a mixture of co-current and counter-current NBI to scan power while holding the torque to a low fixed value. Analysis of the ion and electron heat transport, ion toroidal angular momentum transport, and thermal deuterium transport from these scans is presented. Invariance of the gradients or gradient scalelengths, as might be expected from stiff transport, was not generally observed. When invariance was seen, it was not accompanied by a strong increase in transport, except in the case of the absolute deuterium ion transport. Conduction in the ion channel is the dominant energy loss mechanism. The variation of the ion heat transport with applied power is similar for the co-injection and fixed torque scans, indicating that E  ×  B shearing is not determining the plasma response to additional power. There is however, a quantitative difference in the transport between the two scans, indicating E  ×  B shearing does play a role in the transport. Comparison of these results with a previous experiment that directly probed stiffness at a single radius leads to the following conclusion: while local stiffness as formally defined may hold, invariance of the gradients or normalized scalelengths does not follow from stiff transport in more practical scaling experiments, such as the power scans discussed here. Possible reasons for the lack of correspondence between the local picture and the global expectations are discussed.

  3. Mixed, Nonsplit, Extended Stability, Stiff Integration of Reaction Diffusion Equations

    KAUST Repository

    Alzahrani, Hasnaa H.

    2016-07-26

    A tailored integration scheme is developed to treat stiff reaction-diffusion prob- lems. The construction adapts a stiff solver, namely VODE, to treat reaction im- plicitly together with explicit treatment of diffusion. The second-order Runge-Kutta- Chebyshev (RKC) scheme is adjusted to integrate diffusion. Spatial operator is de- scretised by second-order finite differences on a uniform grid. The overall solution is advanced over S fractional stiff integrations, where S corresponds to the number of RKC stages. The behavior of the scheme is analyzed by applying it to three simple problems. The results show that it achieves second-order accuracy, thus, preserving the formal accuracy of the original RKC. The presented development sets the stage for future extensions, particularly, to multidimensional reacting flows with detailed chemistry.

  4. Stiffness analysis for the micromagnetic standard problem No. 4

    International Nuclear Information System (INIS)

    Tsiantos, Vassilios D.; Suess, Dieter; Schrefl, Thomas; Fidler, Josef

    2001-01-01

    In this article solutions to micromagnetic standard problem No. 4, a 500-nmx125-nm-wide NiFe film, are presented. A three-dimensional-finite element simulation based on the solution of the Gilbert equation has been used. The simulations show that two different reversal mechanisms occur for the two different applied fields. For a field at 170 degree counterclockwise from the saturation direction there is a nonuniform rotation of magnetization towards the direction of the applied field, with the magnetization at the ends rotating faster than the magnetization in the center. For a field at 190 degree counterclockwise from the saturation direction the magnetization at the ends and in the center rotate in opposite directions leading to the formation of a 360 degree wall after 0.22 ns associated with a peak in the exchange energy. Moreover, the time for the magnetization component parallel to the long axis to cross the zero is 0.136 and 0.135 ns for field 1 and field 2, respectively. The stiffness of the problem has been investigated solving the system of ordinary differential equations with a nonstiff method (Adams) and a stiff one (backward differentiation formula, BDF). For the measure of stiffness the ratio of the total number of time steps (nst) taken by the two solvers, that is nst(Adams)/nst(BDF), has been used. This ratio is 0.784 for field 1 and 0.593 for field 2, which means that the nonstiff method (Adams) uses larger time steps than the stiff method (BDF) and consequently the systems are not stiff. The average time step for the Adams method was 0.2 ps for both fields. [copyright] 2001 American Institute of Physics

  5. Reduced prosthetic stiffness lowers the metabolic cost of running for athletes with bilateral transtibial amputations.

    Science.gov (United States)

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-04-01

    Inspired by the springlike action of biological legs, running-specific prostheses are designed to enable athletes with lower-limb amputations to run. However, manufacturer's recommendations for prosthetic stiffness and height may not optimize running performance. Therefore, we investigated the effects of using different prosthetic configurations on the metabolic cost and biomechanics of running. Five athletes with bilateral transtibial amputations each performed 15 trials on a force-measuring treadmill at 2.5 or 3.0 m/s. Athletes ran using each of 3 different prosthetic models (Freedom Innovations Catapult FX6, Össur Flex-Run, and Ottobock 1E90 Sprinter) with 5 combinations of stiffness categories (manufacturer's recommended and ± 1) and heights (International Paralympic Committee's maximum competition height and ± 2 cm) while we measured metabolic rates and ground reaction forces. Overall, prosthetic stiffness [fixed effect (β) = 0.036; P = 0.008] but not height ( P ≥ 0.089) affected the net metabolic cost of transport; less stiff prostheses reduced metabolic cost. While controlling for prosthetic stiffness (in kilonewtons per meter), using the Flex-Run (β = -0.139; P = 0.044) and 1E90 Sprinter prostheses (β = -0.176; P = 0.009) reduced net metabolic costs by 4.3-4.9% compared with using the Catapult prostheses. The metabolic cost of running improved when athletes used prosthetic configurations that decreased peak horizontal braking ground reaction forces (β = 2.786; P = 0.001), stride frequencies (β = 0.911; P < 0.001), and leg stiffness values (β = 0.053; P = 0.009). Remarkably, athletes did not maintain overall leg stiffness across prosthetic stiffness conditions. Rather, the in-series prosthetic stiffness governed overall leg stiffness. The metabolic cost of running in athletes with bilateral transtibial amputations is influenced by prosthetic model and stiffness but not height. NEW & NOTEWORTHY We measured the

  6. The Passive Series Stiffness That Optimizes Torque Tracking for a Lower-Limb Exoskeleton in Human Walking

    Directory of Open Access Journals (Sweden)

    Juanjuan Zhang

    2017-12-01

    Full Text Available This study uses theory and experiments to investigate the relationship between the passive stiffness of series elastic actuators and torque tracking performance in lower-limb exoskeletons during human walking. Through theoretical analysis with our simplified system model, we found that the optimal passive stiffness matches the slope of the desired torque-angle relationship. We also conjectured that a bandwidth limit resulted in a maximum rate of change in torque error that can be commanded through control input, which is fixed across desired and passive stiffness conditions. This led to hypotheses about the interactions among optimal control gains, passive stiffness and desired quasi-stiffness. Walking experiments were conducted with multiple angle-based desired torque curves. The observed lowest torque tracking errors identified for each combination of desired and passive stiffnesses were shown to be linearly proportional to the magnitude of the difference between the two stiffnesses. The proportional gains corresponding to the lowest observed errors were seen inversely proportional to passive stiffness values and to desired stiffness. These findings supported our hypotheses, and provide guidance to application-specific hardware customization as well as controller design for torque-controlled robotic legged locomotion.

  7. Theoretical Design and Characteristics Analysis of a Quasi-Zero Stiffness Isolator Using a Disk Spring as Negative Stiffness Element

    Directory of Open Access Journals (Sweden)

    Lingshuai Meng

    2015-01-01

    Full Text Available This paper presents a novel quasi-zero stiffness (QZS isolator designed by combining a disk spring with a vertical linear spring. The static characteristics of the disk spring and the QZS isolator are investigated. The optimal combination of the configurative parameters is derived to achieve a wide displacement range around the equilibrium position in which the stiffness has a low value and changes slightly. By considering the overloaded or underloaded conditions, the dynamic equations are established for both force and displacement excitations. The frequency response curves (FRCs are obtained by using the harmonic balance method (HBM and confirmed by the numerical simulation. The stability of the steady-state solution is analyzed by applying Floquet theory. The force, absolute displacement, and acceleration transmissibility are defined to evaluate the isolation performance. Effects of the offset displacement, excitation amplitude, and damping ratio on the QZS isolator and the equivalent system (ELS are studied. The results demonstrate that the QZS isolator for overloaded or underloaded can exhibit different stiffness characteristics with changing excitation amplitude. If loaded with an appropriate mass, excited by not too large amplitude, and owned a larger damper, the QZS isolator can possess better isolation performance than its ELS in low frequency range.

  8. Substrate Stiffness Controls Osteoblastic and Chondrocytic Differentiation of Mesenchymal Stem Cells without Exogenous Stimuli.

    Directory of Open Access Journals (Sweden)

    Rene Olivares-Navarrete

    Full Text Available Stem cell fate has been linked to the mechanical properties of their underlying substrate, affecting mechanoreceptors and ultimately leading to downstream biological response. Studies have used polymers to mimic the stiffness of extracellular matrix as well as of individual tissues and shown mesenchymal stem cells (MSCs could be directed along specific lineages. In this study, we examined the role of stiffness in MSC differentiation to two closely related cell phenotypes: osteoblast and chondrocyte. We prepared four methyl acrylate/methyl methacrylate (MA/MMA polymer surfaces with elastic moduli ranging from 0.1 MPa to 310 MPa by altering monomer concentration. MSCs were cultured in media without exogenous growth factors and their biological responses were compared to committed chondrocytes and osteoblasts. Both chondrogenic and osteogenic markers were elevated when MSCs were grown on substrates with stiffness <10 MPa. Like chondrocytes, MSCs on lower stiffness substrates showed elevated expression of ACAN, SOX9, and COL2 and proteoglycan content; COMP was elevated in MSCs but reduced in chondrocytes. Substrate stiffness altered levels of RUNX2 mRNA, alkaline phosphatase specific activity, osteocalcin, and osteoprotegerin in osteoblasts, decreasing levels on the least stiff substrate. Expression of integrin subunits α1, α2, α5, αv, β1, and β3 changed in a stiffness- and cell type-dependent manner. Silencing of integrin subunit beta 1 (ITGB1 in MSCs abolished both osteoblastic and chondrogenic differentiation in response to substrate stiffness. Our results suggest that substrate stiffness is an important mediator of osteoblastic and chondrogenic differentiation, and integrin β1 plays a pivotal role in this process.

  9. Evaluation of stiffness feedback for hard nodule identification on a phantom silicone model

    OpenAIRE

    Li, M.; Konstantinova, J.; Xu, G.; He, B.; Aminzadeh, V.; Xie, J.; Wurdemann, H.; Althoefer, K.

    2017-01-01

    Haptic information in robotic surgery can significantly improve clinical outcomes and help detect hard soft-tissue inclusions that indicate potential abnormalities. Visual representation of tissue stiffness information is a cost-effective technique. Meanwhile, direct force feedback, although considerably more expensive than visual representation, is an intuitive method of conveying information regarding tissue stiffness to surgeons. In this study, real-time visual stiffness feedback by slidin...

  10. Structural damage of chicken red blood cells exposed to platinum nanoparticles and cisplatin

    DEFF Research Database (Denmark)

    Kutwin, Marta; Sawosz, Ewa; Jaworski, Sławomir

    2014-01-01

    of platinum nanoparticles (NP-Pt) and cisplatin with blood compartments are important for future applications. This study investigated structural damage, cell membrane deformation and haemolysis of chicken embryo red blood cells (RBC) after treatment with cisplatin and NP-Pt. Cisplatin (4 μg/ml) and NP-Pt (2......,6 μg/ml), when incubated with chicken embryo RBC, were detrimental to cell structure and induced haemolysis. The level of haemolytic injury was increased after cisplatin and NP-Pt treatments compared to the control group. Treatment with cisplatin caused structural damage to cell membranes...

  11. Spleen Stiffness Correlates with the Presence of Ascites but Not Esophageal Varices in Chronic Hepatitis C Patients

    Directory of Open Access Journals (Sweden)

    Kazuyo Mori

    2013-01-01

    Full Text Available Although spleen stiffness has recently been identified as potential surrogate marker for portal hypertension, the relationship between spleen stiffness and portal hypertension has not been fully elucidated. We attempted to determine the relationship between the liver or spleen stiffness and the presence of ascites or esophageal varices by acoustic radiation force impulse (ARFI imaging. A total of 33 chronic hepatitis C (CHC patients (median age 68; range 51–84 were enrolled. We evaluated the relationship between the liver or spleen stiffness and indicators of portal hypertension as well as clinical and biochemical parameters. Fourteen healthy volunteers were used for validating the accuracy of AFRI imaging. The liver and spleen stiffness increased significantly with progression of liver disease. A significant positive correlation was observed between the liver and spleen stiffness. However, spleen stiffness, but not liver stiffness, was significantly associated with the presence of ascites (, while there was no significant association between the spleen stiffness and spleen index/presence of esophageal varices in CHC patients. The area under the receiver operating characteristic curve based on the spleen stiffness was 0.80. In conclusion, spleen stiffness significantly correlates with the presence of ascites but not esophageal varices in CHC patients.

  12. Effects of plyometric and isometric training on muscle and tendon stiffness in vivo.

    Science.gov (United States)

    Kubo, Keitaro; Ishigaki, Tomonobu; Ikebukuro, Toshihiro

    2017-08-01

    The purpose of this study was to compare the effects of plyometric and isometric training on tendon properties during ramp and ballistic contractions and muscle stiffness under passive and active conditions. Eleven subjects completed 12 weeks (3 days/week) of a unilateral training program for the plantar flexors. They performed plyometric training on one side (PLY) and isometric training on the other side (ISO). Active muscle stiffness in the medial gastrocnemius muscle was calculated according to changes in estimated muscle force and fascicle length during fast stretching after submaximal isometric contractions. Passive muscle stiffness was also calculated from estimated passive muscle force and fascicle length during slow passive stretching. Stiffness and hysteresis of tendon structures were measured using ultrasonography during ramp and ballistic contractions. Passive muscle stiffness and tendon hysteresis did not change for PLY or ISO Active muscle stiffness significantly increased for PLY, but not for ISO Tendon stiffness during ramp and ballistic contractions increased significantly for ISO, but not for PLY In addition, tendon elongation values at force production levels beyond 100 N during ballistic contractions increased for PLY These results suggest that plyometric training (but not isometric training) enhances the extensibility of tendon structures during ballistic contractions and active muscle stiffness during fast stretching, and these changes may be related to improved performances during stretch-shortening cycle exercises. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  13. Hemodynamic and arterial stiffness differences between African-Americans and Caucasians after maximal exercise.

    Science.gov (United States)

    Yan, Huimin; Ranadive, Sushant M; Heffernan, Kevin S; Lane, Abbi D; Kappus, Rebecca M; Cook, Marc D; Wu, Pei-Tzu; Sun, Peng; Harvey, Idethia S; Woods, Jeffrey A; Wilund, Kenneth R; Fernhall, Bo

    2014-01-01

    African-American (AA) men have higher arterial stiffness and augmentation index (AIx) than Caucasian-American (CA) men. Women have greater age-associated increases in arterial stiffness and AIx than men. This study examined racial and sex differences in arterial stiffness and central hemodynamics at rest and after an acute bout of maximal exercise in young healthy individuals. One hundred young, healthy individuals (28 AA men, 24 AA women, 25 CA men, and 23 CA women) underwent measurements of aortic blood pressure (BP) and arterial stiffness at rest and 15 and 30 min after an acute bout of graded maximal aerobic exercise. Aortic BP and AIx were derived from radial artery applanation tonometry. Aortic stiffness (carotid-femoral) was measured via pulse wave velocity. Aortic stiffness was increased in AA subjects but not in CA subjects (P < 0.05) after an acute bout of maximal cycling exercise, after controlling for body mass index. Aortic BP decreased after exercise in CA subjects but not in AA subjects (P < 0.05). Women exhibited greater reductions in AIx after maximal aerobic exercise compared with men (P < 0.05). In conclusion, race and sex impact vascular and central hemodynamic responses to exercise. Young AA and CA subjects exhibited differential responses in central stiffness and central BP after acute maximal exercise. Premenopausal women had greater augmented pressure at rest and after maximal aerobic exercise than men. Future research is needed to examine the potential mechanisms.

  14. Stiffness, resilience, compressibility

    Energy Technology Data Exchange (ETDEWEB)

    Leu, Bogdan M. [Argonne National Laboratory, Advanced Photon Source (United States); Sage, J. Timothy, E-mail: jtsage@neu.edu [Northeastern University, Department of Physics and Center for Interdisciplinary Research on Complex Systems (United States)

    2016-12-15

    The flexibility of a protein is an important component of its functionality. We use nuclear resonance vibrational spectroscopy (NRVS) to quantify the flexibility of the heme iron environment in the electron-carrying protein cytochrome c by measuring the stiffness and the resilience. These quantities are sensitive to structural differences between the active sites of different proteins, as illustrated by a comparative analysis with myoglobin. The elasticity of the entire protein, on the other hand, can be probed quantitatively from NRVS and high energy-resolution inelastic X-ray scattering (IXS) measurements, an approach that we used to extract the bulk modulus of cytochrome c.

  15. Soft Robotic Haptic Interface with Variable Stiffness for Rehabilitation of Neurologically Impaired Hand Function

    Directory of Open Access Journals (Sweden)

    Frederick Sebastian

    2017-12-01

    Full Text Available The human hand comprises complex sensorimotor functions that can be impaired by neurological diseases and traumatic injuries. Effective rehabilitation can bring the impaired hand back to a functional state because of the plasticity of the central nervous system to relearn and remodel the lost synapses in the brain. Current rehabilitation therapies focus on strengthening motor skills, such as grasping, employ multiple objects of varying stiffness so that affected persons can experience a wide range of strength training. These devices have limited range of stiffness due to the rigid mechanisms employed in their variable stiffness actuators. This paper presents a novel soft robotic haptic device for neuromuscular rehabilitation of the hand, which is designed to offer adjustable stiffness and can be utilized in both clinical and home settings. The device eliminates the need for multiple objects by employing a pneumatic soft structure made with highly compliant materials that act as the actuator of the haptic interface. It is made with interchangeable sleeves that can be customized to include materials of varying stiffness to increase the upper limit of the stiffness range. The device is fabricated using existing 3D printing technologies, and polymer molding and casting techniques, thus keeping the cost low and throughput high. The haptic interface is linked to either an open-loop system that allows for an increased pressure during usage or closed-loop system that provides pressure regulation in accordance to the stiffness the user specifies. Preliminary evaluation is performed to characterize the effective controllable region of variance in stiffness. It was found that the region of controllable stiffness was between points 3 and 7, where the stiffness appeared to plateau with each increase in pressure. The two control systems are tested to derive relationships between internal pressure, grasping force exertion on the surface, and displacement using

  16. Arterial stiffness in 10-year-old children: current and early determinants.

    Science.gov (United States)

    Schack-Nielsen, Lene; Mølgaard, Christian; Larsen, Dorthe; Martyn, Christopher; Michaelsen, Kim Fleischer

    2005-12-01

    It has been suggested that CVD has its origins in early life. An impairment of fetal growth and early postnatal nutrition may have programming effects on cardiovascular physiology. In addition, traditional risk factors for CVD may initiate the atherosclerotic process during childhood. We explored the effect of fat intake, physical activity and lipid profile in childhood, and birth weight, growth during infancy and breast-feeding on arterial stiffness in a cohort study of ninety-three 10-year-old children followed during infancy and re-examined at the age of 10 years. Arterial stiffness in two arterial segments (aorto-radial and aorto-femoral) was measured as pulse wave velocity. Arterial stiffness was inversely associated with physical activity (a regression coefficient in cm/s (95 % CI) of -6.8 (-11.2, -2.4) and -3.9 (-6.9, -0.8) per h of high physical activity/d in the aorto-radial and aorto-femoral segments, respectively). Arterial stiffness was also positively associated with dietary fat energy percentage (3.1 (95 % CI 0.9, 5.2) and 1.8 (95 % CI 0.2, 3.2) per fat energy percentage in the aorto-radial and aorto-femoral segments, respectively) but was not related to body composition, insulin resistance or lipid profile. Arterial stiffness was also positively associated with duration of breast-feeding for the aorto-femoral segment only (2.1 (95 % CI 0.4, 3.7) per month) but was not associated with growth in early life. In conclusion, patterns of physical activity and diet, and history of breast-feeding in infancy, have an influence on the stiffness of the large arteries in children. The long-term effects of this are unknown.

  17. A comparison of muscle stiffness and musculoarticular stiffness of the knee joint in young athletic males and females.

    Science.gov (United States)

    Wang, Dan; De Vito, Giuseppe; Ditroilo, Massimiliano; Fong, Daniel T P; Delahunt, Eamonn

    2015-06-01

    The objective of this study was to investigate the gender-specific differences in peak torque (PT), muscle stiffness (MS) and musculoarticular stiffness (MAS) of the knee joints in a young active population. Twenty-two male and twenty-two female recreational athletes participated. PT of the knee joint extensor musculature was assessed on an isokinetic dynamometer, MS of the vastus lateralis (VL) muscle was measured in both relaxed and contracted conditions, and knee joint MAS was quantified using the free oscillation technique. Significant gender differences were observed for all dependent variables. Females demonstrated less normalized PT (mean difference (MD)=0.4Nm/kg, p=0.005, η(2)=0.17), relaxed MS (MD=94.2N/m, pjoint injury incidence and prevalence in females when compared to males. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Correlations among measures of knee stiffness, gait performance and complaints in individuals with knee osteoarthritis.

    Science.gov (United States)

    Oatis, Carol A; Wolff, Edward F; Lockard, Margery A; Michener, Lori A; Robbins, Steven J

    2013-03-01

    Stiffness is a common complaint in individuals with knee osteoarthritis and is a component of the osteoarthritis diagnosis. Yet the relationship between stiffness and function is poorly understood and methods to quantify stiffness are limited. Using a cross-sectional observational design with 66 subjects with knee osteoarthritis, stiffness and damping coefficients were calculated from a relaxed knee oscillation procedure. Gait parameters were measured using an electronic walkway. Self-reported pain, stiffness, and function were measured with the Western Ontario and McMaster Osteoarthritis Index. Correlation and Alexander's normalized-t approximation analyses were used to assess associations among the variables. Subset analysis was performed on subjects with and without tibiofemoral joint crepitus. Slight to moderate correlations existed between stiffness and damping coefficients and most gait parameters ((| r |=0.30-0.56; PMcMaster Osteoarthritis Index scores and all gait parameters (| r |=0.35-0.62; Pcoefficient was only slightly associated with patient-rated Western Ontario and McMaster Osteoarthritis Index stiffness subscale scores. Subset analysis revealed significant correlations that differed between those with and without crepitus. These findings suggest that laboratory measured stiffness and damping coefficients, Western Ontario and McMaster Osteoarthritis Index scores and gait-related measurements assess different aspects related to movement in individuals with knee osteoarthritis. Stiffness and damping coefficients may offer the ability to explain gait changes in the knee that are independent of a person's perceptions particularly in the early stages of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Reduction of magneto rheological dampers stiffness by incorporating of an eddy current damper

    Science.gov (United States)

    Asghar Maddah, Ali; Hojjat, Yousef; Reza Karafi, Mohammad; Reza Ashory, Mohammad

    2017-05-01

    In this paper, a hybrid damper is developed to achieve lower stiffness compared to magneto rheological dampers. The hybrid damper consists of an eddy current damper (ECD) and a Magneto Rheological Damper (MRD). The aim of this research is to reduce the stiffness of MRDs with equal damping forces. This work is done by adding an eddy current passive damper to a semi-active MRD. The ECDs are contactless dampers which show an almost viscous damping behavior without increasing the stiffness of a system. However, MRDs increase damping and stiffness of a system simultaneously, when a magnetic field is applied. Damping of each part is studied theoretically and experimentally. A semi-empirical model is developed to explain the viscoelastic behavior of the damper. The experimental results showed that the hybrid damper is able to dissipate energy as much as those of MRDs while its stiffness is 12% lower at a zero excitation current.

  20. Lamb Wave Stiffness Characterization of Composites Undergoing Thermal-Mechanical Aging

    Science.gov (United States)

    Seale, Michael D.; Madaras, Eric I.

    2004-01-01

    The introduction of new, advanced composite materials into aviation systems requires a thorough understanding of the long term effects of combined thermal and mechanical loading upon those materials. Analytical methods investigating the effects of intense thermal heating combined with mechanical loading have been investigated. The damage mechanisms and fatigue lives were dependent on test parameters as well as stress levels. Castelli, et al. identified matrix dominated failure modes for out-of-phase cycling and fiber dominated damage modes for in-phase cycling. In recent years, ultrasonic methods have been developed that can measure the mechanical stiffness of composites. To help evaluate the effect of aging, a suitably designed Lamb wave measurement system is being used to obtain bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system works by exciting an antisymmetric Lamb wave and calculating the velocity at each frequency from the known transducer separation and the measured time-of-flight. The same peak in the waveforms received at various distances is used to measure the time difference between the signals. The velocity measurements are accurate and repeatable to within 1% resulting in reconstructed stiffness values repeatable to within 4%. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. A mechanical scanner is used to move the sensors over the surface to map the time-of-flight, velocity, or stiffnesses of the entire specimen. Access to only one side of the material is required and no immersion or couplants are required because the sensors are dry coupled to the surface of the plate. In this study, the elastic stiffnesses D(sub 11), D(sub 22), A(sub 44), and A(sub 55) as well as time-of-flight measurements for composite samples that have undergone combined thermal and mechanical aging for

  1. Nanodefects of membranes cause destruction of packed red blood cells during long-term storage

    International Nuclear Information System (INIS)

    Kozlova, Elena; Chernysh, Aleksandr; Moroz, Victor; Sergunova, Victoria; Gudkova, Olga; Kuzovlev, Artem

    2015-01-01

    Packed red blood cells (PRBC) are used for blood transfusion. PRBC were stored for 30 days under 4 °C in hermetic blood bags with CPD anticoagulant-preservative solution. Hematocrit was 50–55%. The distortions of PRBC membranes nanostructure and cells morphology during storage were studied by atomic force microscopy. Basic measurements were performed at the day 2, 6, 9, 16, 23 and 30 of storage and additionally 2–3 days after it. Topological defects occurred on RBC membranes by day 9. They appeared as domains with grain-like structures (“grains”) sized up to 200 nm. These domains were appeared in almost all cells. Later these domains merged and formed large defects on cells. It was the formation of domains with the “grains” which was onset process leading eventually to destruction of PRBC. Possible mechanisms of transformation of PRBC and their membrane are related to the alterations of spectrin cytoskeleton. During this storage period potassium ions and lactat concentrations increased, pH decreased, intracellular concentration of reduced glutathione diminished in the preservative solution. Changes of PRBC morphology were detected within the entire period of PRBC storage. Discocytes predominated at the days 1 and 2. By day 30 PRBC transformed into irreversible echinocytes and spheroechinocytes. Study of defects of membranes nanostructure may form the basis of assessing the quality of the stored PRBC. This method may allow to work out the best recommendations for blood transfusion. - Highlights: • Domains with “grains” are formed on membranes surface on 9–16 days of PRBC storage. • The development of domains is the reason of irreversible changes of PRBC structure. • The origin of domains is the consequence of alterations of spectrin cytoskeleton. • Study of nanostructure may form basis of assessing the quality of the stored PRBC

  2. Nanodefects of membranes cause destruction of packed red blood cells during long-term storage

    Energy Technology Data Exchange (ETDEWEB)

    Kozlova, Elena, E-mail: waterlake@mail.ru [V.A. Negovsky Scientific Research Institute of General Reanimatology, Moscow (Russian Federation); I.M. Sechenov First Moscow State Medical University, Moscow (Russian Federation); Chernysh, Aleksandr [V.A. Negovsky Scientific Research Institute of General Reanimatology, Moscow (Russian Federation); I.M. Sechenov First Moscow State Medical University, Moscow (Russian Federation); Moroz, Victor; Sergunova, Victoria; Gudkova, Olga; Kuzovlev, Artem [V.A. Negovsky Scientific Research Institute of General Reanimatology, Moscow (Russian Federation)

    2015-10-01

    Packed red blood cells (PRBC) are used for blood transfusion. PRBC were stored for 30 days under 4 °C in hermetic blood bags with CPD anticoagulant-preservative solution. Hematocrit was 50–55%. The distortions of PRBC membranes nanostructure and cells morphology during storage were studied by atomic force microscopy. Basic measurements were performed at the day 2, 6, 9, 16, 23 and 30 of storage and additionally 2–3 days after it. Topological defects occurred on RBC membranes by day 9. They appeared as domains with grain-like structures (“grains”) sized up to 200 nm. These domains were appeared in almost all cells. Later these domains merged and formed large defects on cells. It was the formation of domains with the “grains” which was onset process leading eventually to destruction of PRBC. Possible mechanisms of transformation of PRBC and their membrane are related to the alterations of spectrin cytoskeleton. During this storage period potassium ions and lactat concentrations increased, pH decreased, intracellular concentration of reduced glutathione diminished in the preservative solution. Changes of PRBC morphology were detected within the entire period of PRBC storage. Discocytes predominated at the days 1 and 2. By day 30 PRBC transformed into irreversible echinocytes and spheroechinocytes. Study of defects of membranes nanostructure may form the basis of assessing the quality of the stored PRBC. This method may allow to work out the best recommendations for blood transfusion. - Highlights: • Domains with “grains” are formed on membranes surface on 9–16 days of PRBC storage. • The development of domains is the reason of irreversible changes of PRBC structure. • The origin of domains is the consequence of alterations of spectrin cytoskeleton. • Study of nanostructure may form basis of assessing the quality of the stored PRBC.

  3. Rotational stiffness of American football shoes affects ankle biomechanics and injury severity.

    Science.gov (United States)

    Button, Keith D; Braman, Jerrod E; Davison, Mark A; Wei, Feng; Schaeffer, Maureen C; Haut, Roger C

    2015-06-01

    While previous studies have investigated the effect of shoe-surface interaction on injury risk, few studies have examined the effect of rotational stiffness of the shoe. The hypothesis of the current study was that ankles externally rotated to failure in shoes with low rotational stiffness would allow more talus eversion than those in shoes with a higher rotational stiffness, resulting in less severe injury. Twelve (six pairs) cadaver lower extremities were externally rotated to gross failure while positioned in 20 deg of pre-eversion and 20 deg of predorsiflexion by fixing the distal end of the foot, axially loading the proximal tibia, and internally rotating the tibia. One ankle in each pair was constrained by an American football shoe with a stiff upper, while the other was constrained by an American football shoe with a flexible upper. Experimental bone motions were input into specimen-specific computational models to examine levels of ligament elongation to help understand mechanisms of ankle joint failure. Ankles in flexible shoes allowed 6.7±2.4 deg of talus eversion during rotation, significantly greater than the 1.7±1.0 deg for ankles in stiff shoes (p = 0.01). The significantly greater eversion in flexible shoes was potentially due to a more natural response of the ankle during rotation, possibly affecting the injuries that were produced. All ankles failed by either medial ankle injury or syndesmotic injury, or a combination of both. Complex (more than one ligament or bone) injuries were noted in 4 of 6 ankles in stiff shoes and 1 of 6 ankles in flexible shoes. Ligament elongations from the computational model validated the experimental injury data. The current study suggested flexibility (or rotational stiffness) of the shoe may play an important role in both the severity of ankle injuries for athletes.

  4. Salt Bridge Formation between the I-BAR Domain and Lipids Increases Lipid Density and Membrane Curvature.

    Science.gov (United States)

    Takemura, Kazuhiro; Hanawa-Suetsugu, Kyoko; Suetsugu, Shiro; Kitao, Akio

    2017-07-28

    The BAR domain superfamily proteins sense or induce curvature in membranes. The inverse-BAR domain (I-BAR) is a BAR domain that forms a straight "zeppelin-shaped" dimer. The mechanisms by which IRSp53 I-BAR binds to and deforms a lipid membrane are investigated here by all-atom molecular dynamics simulation (MD), binding energy analysis, and the effects of mutation experiments on filopodia on HeLa cells. I-BAR adopts a curved structure when crystallized, but adopts a flatter shape in MD. The binding of I-BAR to membrane was stabilized by ~30 salt bridges, consistent with experiments showing that point mutations of the interface residues have little effect on the binding affinity whereas multiple mutations have considerable effect. Salt bridge formation increases the local density of lipids and deforms the membrane into a concave shape. In addition, the point mutations that break key intra-molecular salt bridges within I-BAR reduce the binding affinity; this was confirmed by expressing these mutants in HeLa cells and observing their effects. The results indicate that the stiffness of I-BAR is important for membrane deformation, although I-BAR does not act as a completely rigid template.

  5. Magnetic resonance elastography: Feasibility of liver stiffness measurements in healthy volunteers at 3 T

    International Nuclear Information System (INIS)

    Mannelli, L.; Godfrey, E.; Graves, M.J.; Patterson, A.J.; Beddy, P.; Bowden, D.; Joubert, I.; Priest, A.N.; Lomas, D.J.

    2012-01-01

    Aim: To demonstrate the feasibility of obtaining liver stiffness measurements with magnetic resonance elastography (MRE) at 3 T in normal healthy volunteers using the same technique that has been successfully applied at 1.5 T. Methods and materials: The study was approved by the local ethics committee and written informed consent was obtained from all volunteers. Eleven volunteers (mean age 35 ± 9 years) with no history of gastrointestinal, hepatobiliary, or cardiovascular disease were recruited. The magnetic resonance imaging (MRI) protocol included a gradient echo-based MRE sequence using a 60 Hz pneumatic excitation. The MRE images were processed using a local frequency estimation inversion algorithm to provide quantitative stiffness maps. Adequate image quality was assessed subjectively by demonstrating the presence of visible propagating waves within the liver parenchyma underlying the driver location. Liver stiffness values were obtained using manually placed regions of interest (ROI) outlining the liver margins on the gradient echo wave images, which were then mapped onto the corresponding stiffness image. The mean stiffness values from two adjacent sections were recorded. Results: Eleven volunteers underwent MRE. The quality of the MRE images was adequate in all the volunteers. The mean liver stiffness for the group was 2.3 ± 0.38 kPa (ranging from 1.7–2.8 kPa). Conclusions: This preliminary work using MRE at 3 T in healthy volunteers demonstrates the feasibility of liver stiffness evaluation at 3 T without modification of the approach used at 1.5 T. Adequate image quality and normal MRE values were obtained in all volunteers. The obtained stiffness values were in the range of those reported for healthy volunteers in previous studies at 1.5 T. There was good interobserver reproducibility in the stiffness measurements.

  6. Magnetic resonance elastography: Feasibility of liver stiffness measurements in healthy volunteers at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Mannelli, L., E-mail: mannellilorenzo@yahoo.it [Department of Radiology, Addenbrooke' s Hospital and University of Cambridge, Cambridge (United Kingdom); Department of Radiology, University of Washington, Seattle, WA (United States); Godfrey, E.; Graves, M.J.; Patterson, A.J.; Beddy, P.; Bowden, D.; Joubert, I.; Priest, A.N.; Lomas, D.J. [Department of Radiology, Addenbrooke' s Hospital and University of Cambridge, Cambridge (United Kingdom)

    2012-03-15

    Aim: To demonstrate the feasibility of obtaining liver stiffness measurements with magnetic resonance elastography (MRE) at 3 T in normal healthy volunteers using the same technique that has been successfully applied at 1.5 T. Methods and materials: The study was approved by the local ethics committee and written informed consent was obtained from all volunteers. Eleven volunteers (mean age 35 {+-} 9 years) with no history of gastrointestinal, hepatobiliary, or cardiovascular disease were recruited. The magnetic resonance imaging (MRI) protocol included a gradient echo-based MRE sequence using a 60 Hz pneumatic excitation. The MRE images were processed using a local frequency estimation inversion algorithm to provide quantitative stiffness maps. Adequate image quality was assessed subjectively by demonstrating the presence of visible propagating waves within the liver parenchyma underlying the driver location. Liver stiffness values were obtained using manually placed regions of interest (ROI) outlining the liver margins on the gradient echo wave images, which were then mapped onto the corresponding stiffness image. The mean stiffness values from two adjacent sections were recorded. Results: Eleven volunteers underwent MRE. The quality of the MRE images was adequate in all the volunteers. The mean liver stiffness for the group was 2.3 {+-} 0.38 kPa (ranging from 1.7-2.8 kPa). Conclusions: This preliminary work using MRE at 3 T in healthy volunteers demonstrates the feasibility of liver stiffness evaluation at 3 T without modification of the approach used at 1.5 T. Adequate image quality and normal MRE values were obtained in all volunteers. The obtained stiffness values were in the range of those reported for healthy volunteers in previous studies at 1.5 T. There was good interobserver reproducibility in the stiffness measurements.

  7. Contact stiffness and damping of liquid films in dynamic atomic force microscope

    International Nuclear Information System (INIS)

    Xu, Rong-Guang; Leng, Yongsheng

    2016-01-01

    The mechanical properties and dissipation behaviors of nanometers confined liquid films have been long-standing interests in surface force measurements. The correlation between the contact stiffness and damping of the nanoconfined film is still not well understood. We establish a novel computational framework through molecular dynamics (MD) simulation for the first time to study small-amplitude dynamic atomic force microscopy (dynamic AFM) in a simple nonpolar liquid. Through introducing a tip driven dynamics to mimic the mechanical oscillations of the dynamic AFM tip-cantilever assembly, we find that the contact stiffness and damping of the confined film exhibit distinct oscillations within 6-7 monolayer distances, and they are generally out-of-phase. For the solid-like film with integer monolayer thickness, further compression of the film before layering transition leads to higher stiffness and lower damping, while much lower stiffness and higher damping occur at non-integer monolayer distances. These two alternating mechanisms dominate the mechanical properties and dissipation behaviors of simple liquid films under cyclic elastic compression and inelastic squeeze-out. Our MD simulations provide a direct picture of correlations between the structural property, mechanical stiffness, and dissipation behavior of the nanoconfined film.

  8. Contact stiffness and damping of liquid films in dynamic atomic force microscope

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Rong-Guang; Leng, Yongsheng, E-mail: leng@gwu.edu [Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC 20052 (United States)

    2016-04-21

    The mechanical properties and dissipation behaviors of nanometers confined liquid films have been long-standing interests in surface force measurements. The correlation between the contact stiffness and damping of the nanoconfined film is still not well understood. We establish a novel computational framework through molecular dynamics (MD) simulation for the first time to study small-amplitude dynamic atomic force microscopy (dynamic AFM) in a simple nonpolar liquid. Through introducing a tip driven dynamics to mimic the mechanical oscillations of the dynamic AFM tip-cantilever assembly, we find that the contact stiffness and damping of the confined film exhibit distinct oscillations within 6-7 monolayer distances, and they are generally out-of-phase. For the solid-like film with integer monolayer thickness, further compression of the film before layering transition leads to higher stiffness and lower damping, while much lower stiffness and higher damping occur at non-integer monolayer distances. These two alternating mechanisms dominate the mechanical properties and dissipation behaviors of simple liquid films under cyclic elastic compression and inelastic squeeze-out. Our MD simulations provide a direct picture of correlations between the structural property, mechanical stiffness, and dissipation behavior of the nanoconfined film.

  9. Simultaneous measurement of eye stiffness and contact area for living human eyes.

    Science.gov (United States)

    Kurita, Yuichi; Iida, Yoshichika; Kaneko, Makoto; Mishima, Hiromu K; Katakura, Seiki; Kiuchi, Yoshiaki

    2007-01-01

    Goldmann applanation tonometry is commonly used for measuring IOP (IntraOcular Pressure) to diagnose glaucoma. However, the measured IOP by the applanation tonometry is valid only under the assumption that all the subjects have the same structural eye stiffness. Abnormal eye stiffness makes abnormal corneal deformation and thus the current applanation tonometer misestimates the IOP. This study challenges to measure the eye stiffness in vivo with a non-invasive approach for detecting the abnormal deformation. The deformation of the cornea and the contact area between the probe and the cornea are simultaneously captured by cameras during the experiment. Experimental results show that some subjects have different relationship among the force, the displacement and the contact area even with same IOP. The proposed eye stiffness measurement can help detecting the abnormal deformation and the eyes with misestimated IOP.

  10. Stiffness Customization and Patterning for Property Modulation of Silicone-Based Soft Pneumatic Actuators.

    Science.gov (United States)

    Sun, Yi; Yap, Hong Kai; Liang, Xinquan; Guo, Jin; Qi, Peng; Ang, Marcelo H; Yeow, Chen-Hua

    2017-09-01

    Soft pneumatic actuators (SPAs), as novel types of motion drivers for robotic devices, excel in many applications, such as rehabilitation and biomimicry, which demand compliance and softness. To further expand their scope of utilization, the SPAs should be customizable to meet the distinctive requirements of different applications. This article proposes a novel perspective on the SPA working mechanism based on stiffness distribution and then presents a versatile method called stiffness customization and patterning (SCP) for SPA body stiffness layout as a novel attempt to customize SPAs with distinctive properties. We fabricated a hybrid type of material combining unstretchable material and silicone with customizable aggregated elasticity. The tensile results showed that embedding unstretchable material directly increases the stiffness of the hybrid material sample, and our stress-strain model for SCP is able to adequately predict the elasticity of hybrid samples with specific material ratios. By applying this approach to bending-type SPAs, we are able to mitigate SPA buckling, a main failure mode of SPAs, and improve the SPA tip force by using hybrid material with globally increased stiffness. We also diversify bending modalities with different stiffness configurations in the hybrid material. SCP offers numerous ways to engineer SPAs for more applications.

  11. Time dependency of morphological remodeling of endothelial cells in response to substrate stiffness

    Science.gov (United States)

    Goli-Malekabadi, Zahra; Tafazzoli-shadpour, Mohammad; Tamayol, Ali; Seyedjafari, Ehsan

    2017-01-01

    Introduction: Substrate stiffness regulates cellular behavior as cells experience different stiffness values of tissues in the body. For example, endothelial cells (ECs) covering the inner layer of blood vessels are exposed to different stiffness values due to various pathologic and physiologic conditions. Despite numerous studies, cells by time span sense mechanical properties of the substrate, but the response is not well understood. We hypothesized that time is a major determinant influencing the behavior of cells seeded on substrates of varying stiffness. Methods: We monitored cell spreading, internal structure, 3D topography, and the viability of ECs over 24 hours of culture on polydimethylsiloxane (PDMS) substrates with two different degrees of elastic modulus. Results: Despite significant differences in cell spreading after cell seeding, cells showed a similar shape and internal structure after 24 hours of culture on both soft and stiff substrates. However, 3D topographical images confirmed existence of rich lamellipodia and filopodia around the cells cultured on stiffer PDMS substrates. Conclusion: It was concluded that the response of ECs to the substrate stiffness was time dependent with initial enhanced cellular spreading and viability on stiffer substrates. Results can provide a better comprehension of cell mechanotransduction for tissue engineering applications. PMID:28546952

  12. Laminar shear stress modulates endothelial luminal surface stiffness in a tissue-specific manner.

    Science.gov (United States)

    Merna, Nick; Wong, Andrew K; Barahona, Victor; Llanos, Pierre; Kunar, Balvir; Palikuqi, Brisa; Ginsberg, Michael; Rafii, Shahin; Rabbany, Sina Y

    2018-04-17

    Endothelial cells form vascular beds in all organs and are exposed to a range of mechanical forces that regulate cellular phenotype. We sought to determine the role of endothelial luminal surface stiffness in tissue-specific mechanotransduction of laminar shear stress in microvascular mouse cells and the role of arachidonic acid in mediating this response. Microvascular mouse endothelial cells were subjected to laminar shear stress at 4 dynes/cm 2 for 12 hours in parallel plate flow chambers that enabled real-time optical microscopy and atomic force microscopy measurements of cell stiffness. Lung endothelial cells aligned parallel to flow, while cardiac endothelial cells did not. This rapid alignment was accompanied by increased cell stiffness. The addition of arachidonic acid to cardiac endothelial cells increased alignment and stiffness in response to shear stress. Inhibition of arachidonic acid in lung endothelial cells and embryonic stem cell-derived endothelial cells prevented cellular alignment and decreased cell stiffness. Our findings suggest that increased endothelial luminal surface stiffness in microvascular cells may facilitate mechanotransduction and alignment in response to laminar shear stress. Furthermore, the arachidonic acid pathway may mediate this tissue-specific process. An improved understanding of this response will aid in the treatment of organ-specific vascular disease. © 2018 John Wiley & Sons Ltd.

  13. Augmented vascular smooth muscle cell stiffness and adhesion when hypertension is superimposed on aging.

    Science.gov (United States)

    Sehgel, Nancy L; Sun, Zhe; Hong, Zhongkui; Hunter, William C; Hill, Michael A; Vatner, Dorothy E; Vatner, Stephen F; Meininger, Gerald A

    2015-02-01

    Hypertension and aging are both recognized to increase aortic stiffness, but their interactions are not completely understood. Most previous studies have attributed increased aortic stiffness to changes in extracellular matrix proteins that alter the mechanical properties of the vascular wall. Alternatively, we hypothesized that a significant component of increased vascular stiffness in hypertension is due to changes in the mechanical and adhesive properties of vascular smooth muscle cells, and that aging would augment the contribution from vascular smooth muscle cells when compared with the extracellular matrix. Accordingly, we studied aortic stiffness in young (16-week-old) and old (64-week-old) spontaneously hypertensive rats and Wistar-Kyoto wild-type controls. Systolic and pulse pressures were significantly increased in young spontaneously hypertensive rats when compared with young Wistar-Kyoto rats, and these continued to rise in old spontaneously hypertensive rats when compared with age-matched controls. Excised aortic ring segments exhibited significantly greater elastic moduli in both young and old spontaneously hypertensive rats versus Wistar-Kyoto rats. were isolated from the thoracic aorta, and stiffness and adhesion to fibronectin were measured by atomic force microscopy. Hypertension increased both vascular smooth muscle cell stiffness and vascular smooth muscle cell adhesion, and these increases were both augmented with aging. By contrast, hypertension did not affect histological measures of aortic collagen and elastin, which were predominantly changed by aging. These findings support the concept that stiffness and adhesive properties of vascular smooth muscle cells are novel mechanisms contributing to the increased aortic stiffness occurring with hypertension superimposed on aging. © 2014 American Heart Association, Inc.

  14. Arterial stiffness and wave reflection: sex differences and relationship with left ventricular diastolic function.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Palmieri, Vittorio; Homma, Shunichi; Rundek, Tatjana; Elkind, Mitchell S V; Sacco, Ralph L; Di Tullio, Marco R

    2012-08-01

    Increased arterial stiffness and wave reflection have been reported in heart failure with normal ejection fraction (HFNEF) and in asymptomatic left ventricular (LV) diastolic dysfunction, a precursor of HFNEF. It is unclear whether women, who have higher frequency of HFNEF, are more vulnerable than men to the deleterious effects of arterial stiffness on LV diastolic function. We investigated, in a large community-based cohort, whether sex differences exist in the relationship among arterial stiffness, wave reflection, and LV diastolic function. Arterial stiffness and wave reflection were assessed in 983 participants from the Cardiovascular Abnormalities and Brain Lesions study using applanation tonometry. The central pulse pressure/stroke volume index, total arterial compliance, pulse pressure amplification, and augmentation index were used as parameters of arterial stiffness and wave reflection. LV diastolic function was evaluated by 2-dimensional echocardiography and tissue-Doppler imaging. Arterial stiffness and wave reflection were greater in women compared with men, independent of body size and heart rate (all Pfunction in both sexes. Further adjustment for cardiovascular risk factors attenuated these relationships; however, a higher central pulse pressure/stroke volume index predicted LV diastolic dysfunction in women (odds ratio, 1.54; 95% confidence intervals, 1.03 to 2.30) and men (odds ratio, 2.09; 95% confidence interval, 1.30 to 3.39), independent of other risk factors. In conclusion, in our community-based cohort study, higher arterial stiffness was associated with worse LV diastolic function in men and women. Women's higher arterial stiffness, independent of body size, may contribute to their greater susceptibility to develop HFNEF.

  15. Verification and sensitivity analysis on the elastic stiffness of the leaf type holddown spring assembly

    International Nuclear Information System (INIS)

    Song, Kee Nam

    1998-01-01

    The elastic formula of leaf type hold down spring(HDS) assembly is verified by comparing the values of elastic stiffness with the characteristic test results of the HDS's specimens. The comparisons show that the derived elastic stiffness formula is useful in reliably estimating the elastic stiffness of leaf type HDS assembly. The elastic stiffness sensitivity of leaf type HDS assembly is analyzed using the formula and its gradient vectors obtained from the mid-point formula. As a result of sensitivity analysis, the elastic stiffness sensitivity with respect to each design variable is quantified and design variables of large sensitivity are identified. Among the design variables, leaf thickness is identified as the most sensitive design variable to the elastic of leaf type HDS assembly. In addition, the elastic stiffness sensitivity, with respect to design variable, is in power-law type correlation to the base thickness of the leaf. (author)

  16. Muscle contributions to elbow joint rotational stiffness in preparation for sudden external arm perturbations.

    Science.gov (United States)

    Holmes, Michael W R; Keir, Peter J

    2014-04-01

    Understanding joint stiffness and stability is beneficial for assessing injury risk. The purpose of this study was to examine joint rotational stiffness for individual muscles contributing to elbow joint stability. Fifteen male participants maintained combinations of three body orientations (standing, supine, sitting) and three hand preloads (no load, solid tube, fluid filled tube) while a device imposed a sudden elbow extension. Elbow angle and activity from nine muscles were inputs to a biomechanical model to determine relative contributions to elbow joint rotational stiffness, reported as percent of total stiffness. A body orientation by preload interaction was evident for most muscles (Psafety.

  17. Controlled lecithin release from a hierarchical architecture on blood-contacting surface to reduce hemolysis of stored red blood cells.

    Science.gov (United States)

    Shi, Qiang; Fan, Qunfu; Ye, Wei; Hou, Jianwen; Wong, Shing-Chung; Xu, Xiaodong; Yin, Jinghua

    2014-06-25

    Hemolysis of red blood cells (RBCs) caused by implant devices in vivo and nonpolyvinyl chloride containers for RBC preservation in vitro has recently gained much attention. To develop blood-contacting biomaterials with long-term antihemolysis capability, we present a facile method to construct a hydrophilic, 3D hierarchical architecture on the surface of styrene-b-(ethylene-co-butylene)-b-styrene elastomer (SEBS) with poly(ethylene oxide) (PEO)/lecithin nano/microfibers. The strategy is based on electrospinning of PEO/lecithin fibers onto the surface of poly [poly(ethylene glycol) methyl ether methacrylate] [P(PEGMEMA)]-modified SEBS, which renders SEBS suitable for RBC storage in vitro. We demonstrate that the constructed 3D architecture is composed of hydrophilic micro- and nanofibers, which transforms to hydrogel networks immediately in blood; the controlled release of lecithin is achieved by gradual dissolution of PEO/lecithin hydrogels, and the interaction of lecithin with RBCs maintains the membrane flexibility and normal RBC shape. Thus, the blood-contacting surface reduces both mechanical and oxidative damage to RBC membranes, resulting in low hemolysis of preserved RBCs. This work not only paves new way to fabricate high hemocompatible biomaterials for RBC storage in vitro, but provides basic principles to design and develop antihemolysis biomaterials for implantation in vivo.

  18. A comparison and update of direct kinematic-kinetic models of leg stiffness in human running.

    Science.gov (United States)

    Liew, Bernard X W; Morris, Susan; Masters, Ashleigh; Netto, Kevin

    2017-11-07

    Direct kinematic-kinetic modelling currently represents the "Gold-standard" in leg stiffness quantification during three-dimensional (3D) motion capture experiments. However, the medial-lateral components of ground reaction force and leg length have been neglected in current leg stiffness formulations. It is unknown if accounting for all 3D would alter healthy biologic estimates of leg stiffness, compared to present direct modelling methods. This study compared running leg stiffness derived from a new method (multiplanar method) which includes all three Cartesian axes, against current methods which either only include the vertical axis (line method) or only the plane of progression (uniplanar method). Twenty healthy female runners performed shod overground running at 5.0 m/s. Three-dimensional motion capture and synchronised in-ground force plates were used to track the change in length of the leg vector (hip joint centre to centre of pressure) and resultant projected ground reaction force. Leg stiffness was expressed as dimensionless units, as a percentage of an individual's bodyweight divided by standing leg length (BW/LL). Leg stiffness using the line method was larger than the uniplanar method by 15.6%BW/LL (P method by 24.2%BW/LL (P stiffness from the uniplanar method was larger than the multiplanar method by 8.5%BW/LL (6.5 kN/m) (P stiffness estimate with the multiplanar method. Given that limb movements typically occur in 3D, the new multiplanar method provides the most complete accounting of all force and length components in leg stiffness calculation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Development and assessment of a practical stiffness reduction method for the in-plane design of steel frames

    OpenAIRE

    Kucukler, M; Gardner, L; Macorini, L

    2016-01-01

    In this paper, the development and assessment of a stiffness reduction method for the in-plane design of steel frames is presented. The adopted stiffness reduction approach is implemented by reducing the flexural stiffnesses (EI) of the members of a steel frame by considering the first-order forces they are subjected to through the stiffness reduction functions and performing Geometrically Nonlinear Analysis (i.e. second-order elastic analysis). Since the presented approach uses stiffness red...

  20. Circadian blood pressure variability in type 1 diabetes subjects and their nondiabetic siblings - influence of erythrocyte electron transfer.

    Science.gov (United States)

    Matteucci, Elena; Consani, Cristina; Masoni, Maria Chiara; Giampietro, Ottavio

    2010-10-05

    Normotensive non-diabetic relatives of type 1 diabetes (T1D) patients have an abnormal blood pressure response to exercise testing that is associated with indices of metabolic syndrome and increased oxidative stress. The primary aim of this study was to investigate the circadian variability of blood pressure and the ambulatory arterial stiffness index (AASI) in healthy siblings of T1D patients vs healthy control subjects who had no first-degree relative with T1D. Secondary aims of the study were to explore the influence of both cardiovascular autonomic function and erythrocyte electron transfer activity as oxidative marker on the ambulatory blood pressure profile. Twenty-four hour ambulatory blood pressure monitoring (ABPM) was undertaken in 25 controls, 20 T1D patients and 20 siblings. In addition to laboratory examination (including homeostasis model assessment of insulin sensitivity) and clinical testing of autonomic function, we measured the rate of oxidant-induced erythrocyte electron transfer to extracellular ferricyanide (RBC vfcy). Systolic blood pressure (SBP) midline-estimating statistic of rhythm and pulse pressure were higher in T1D patients and correlated positively with diabetes duration and RBC vfcy; autonomic dysfunction was associated with diastolic BP ecphasia and increased AASI. Siblings had higher BMI, lower insulin sensitivity, larger SBP amplitude, and higher AASI than controls. Daytime SBP was positively, independently associated with BMI and RBC vfcy. Among non-diabetic people, there was a significant correlation between AASI and fasting plasma glucose. Siblings of T1D patients exhibited a cluster of sub-clinical metabolic abnormalities associated with consensual perturbations in BP variability. Moreover, our findings support, in a clinical setting, the proposed role of transplasma membrane electron transport systems in vascular pathobiology.

  1. Circadian blood pressure variability in type 1 diabetes subjects and their nondiabetic siblings - influence of erythrocyte electron transfer

    Directory of Open Access Journals (Sweden)

    Masoni Maria

    2010-10-01

    Full Text Available Abstract Background Normotensive non-diabetic relatives of type 1 diabetes (T1D patients have an abnormal blood pressure response to exercise testing that is associated with indices of metabolic syndrome and increased oxidative stress. The primary aim of this study was to investigate the circadian variability of blood pressure and the ambulatory arterial stiffness index (AASI in healthy siblings of T1D patients vs healthy control subjects who had no first-degree relative with T1D. Secondary aims of the study were to explore the influence of both cardiovascular autonomic function and erythrocyte electron transfer activity as oxidative marker on the ambulatory blood pressure profile. Methods Twenty-four hour ambulatory blood pressure monitoring (ABPM was undertaken in 25 controls, 20 T1D patients and 20 siblings. In addition to laboratory examination (including homeostasis model assessment of insulin sensitivity and clinical testing of autonomic function, we measured the rate of oxidant-induced erythrocyte electron transfer to extracellular ferricyanide (RBC vfcy. Results Systolic blood pressure (SBP midline-estimating statistic of rhythm and pulse pressure were higher in T1D patients and correlated positively with diabetes duration and RBC vfcy; autonomic dysfunction was associated with diastolic BP ecphasia and increased AASI. Siblings had higher BMI, lower insulin sensitivity, larger SBP amplitude, and higher AASI than controls. Daytime SBP was positively, independently associated with BMI and RBC vfcy. Among non-diabetic people, there was a significant correlation between AASI and fasting plasma glucose. Conclusions Siblings of T1D patients exhibited a cluster of sub-clinical metabolic abnormalities associated with consensual perturbations in BP variability. Moreover, our findings support, in a clinical setting, the proposed role of transplasma membrane electron transport systems in vascular pathobiology.

  2. Effect of Acute Resistance Exercise on Carotid Artery Stiffness and Cerebral Blood Flow Pulsatility

    Directory of Open Access Journals (Sweden)

    Wesley K Lefferts

    2014-03-01

    Full Text Available Arterial stiffness is associated with cerebral flow pulsatility. Arterial stiffness increases following acute resistance exercise (RE. Whether this acute RE-induced vascular stiffening affects cerebral pulsatility remains unknown. Purpose: To investigate the effects of acute RE on common carotid artery (CCA stiffness and cerebral blood flow velocity (CBFv pulsatility. Methods: Eighteen healthy men (22 ± 1 yr; 23.7 ± 0.5 kg∙m-2 underwent acute RE (5 sets, 5-RM bench press, 5 sets 10-RM bicep curls with 90 s rest intervals or a time control condition (seated rest in a randomized order. CCA stiffness (β-stiffness, Elastic Modulus (Ep and hemodynamics (pulsatility index, forward wave intensity and reflected wave intensity were assessed using a combination of Doppler ultrasound, wave intensity analysis and applanation tonometry at baseline and 3 times post-RE. CBFv pulsatility index was measured with transcranial Doppler at the middle cerebral artery (MCA. Results: CCA β-stiffness, Ep and CCA pulse pressure significantly increased post-RE and remained elevated throughout post-testing (p 0.05. There were significant increases in forward wave intensity post-RE (p0.05. Conclusion: Although acute RE increases CCA stiffness and pressure pulsatility, it may not affect CCA or MCA flow pulsatility. Increases in pressure pulsatility may be due to increased forward wave intensity and not pressure from wave reflections.

  3. Modeling and simulating the neuromuscular mechanisms regulating ankle and knee joint stiffness during human locomotion.

    Science.gov (United States)

    Sartori, Massimo; Maculan, Marco; Pizzolato, Claudio; Reggiani, Monica; Farina, Dario

    2015-10-01

    This work presents an electrophysiologically and dynamically consistent musculoskeletal model to predict stiffness in the human ankle and knee joints as derived from the joints constituent biological tissues (i.e., the spanning musculotendon units). The modeling method we propose uses electromyography (EMG) recordings from 13 muscle groups to drive forward dynamic simulations of the human leg in five healthy subjects during overground walking and running. The EMG-driven musculoskeletal model estimates musculotendon and resulting joint stiffness that is consistent with experimental EMG data as well as with the experimental joint moments. This provides a framework that allows for the first time observing 1) the elastic interplay between the knee and ankle joints, 2) the individual muscle contribution to joint stiffness, and 3) the underlying co-contraction strategies. It provides a theoretical description of how stiffness modulates as a function of muscle activation, fiber contraction, and interacting tendon dynamics. Furthermore, it describes how this differs from currently available stiffness definitions, including quasi-stiffness and short-range stiffness. This work offers a theoretical and computational basis for describing and investigating the neuromuscular mechanisms underlying human locomotion. Copyright © 2015 the American Physiological Society.

  4. Analysis of contact stiffness in ultrasound atomic force microscopy: three-dimensional time-dependent ultrasound modeling

    International Nuclear Information System (INIS)

    Piras, Daniele; Sadeghian, Hamed

    2017-01-01

    Ultrasound atomic force microscopy (US-AFM) has been used for subsurface imaging of nanostructures. The contact stiffness variations have been suggested as the origin of the image contrast. Therefore, to analyze the image contrast, the local changes in the contact stiffness due to the presence of subsurface features should be calculated. So far, only static simulations have been conducted to analyze the local changes in the contact stiffness and, consequently, the contrast in US-AFM. Such a static approach does not fully represent the real US-AFM experiment, where an ultrasound wave is launched either into the sample or at the tip, which modulates the contact stiffness. This is a time-dependent nonlinear dynamic problem rather than a static and stationary one. This paper presents dynamic 3D ultrasound analysis of contact stiffness in US-AFM (in contrast to static analysis) to realistically predict the changes in contact stiffness and thus the changes in the subsurface image contrast. The modulation frequency also influences the contact stiffness variations and, thus, the image contrast. The three-dimensional time-dependent ultrasound analysis will greatly aid in the contrast optimization of subsurface nano imaging with US-AFM. (paper)

  5. Investigation of shape memory of red blood cells using optical tweezers and quantitative phase microscopy

    Science.gov (United States)

    Cardenas, Nelson; Mohanty, Samarendra K.

    2012-03-01

    RBC has been shown to possess shape memory subsequent to shear-induced shape transformation. However, this property of RBC may not be generalized to all kinds of stresses. Here, we report our observation on the action of radiation pressure forces on RBC's shape memory using optical manipulation and quantitative phase microscopy (OMQPM). QPM, based on Mach-Zehnder interferrometry, allowed measurement of dynamic changes of shape of RBC in optical tweezers at different trapping laser powers. In high power near-infrared optical tweezers (>200mW), the RBC was found to deform significantly due to optical forces. Upon removal of the tweezers, hysteresis in recovering its original resting shape was observed. In very high power tweezers or long-term stretching events, shape memory was almost erased. This irreversibility of the deformation may be due to temperature rise or stress-induced phase transformation of lipids in RBC membrane.

  6. Spinal Stiffness in Prone and Upright Postures During 0-1.8 g Induced by Parabolic Flight.

    Science.gov (United States)

    Swanenburg, Jaap; Meier, Michael L; Langenfeld, Anke; Schweinhardt, Petra; Humphreys, B Kim

    2018-06-01

    The purpose of this study was to analyze posterior-to-anterior spinal stiffness in Earth, hyper-, and microgravity conditions during both prone and upright postures. During parabolic flight, the spinal stiffness of the L3 vertebra of a healthy 37-yr-old man was measured in normal Earth gravity (1.0 g), hypergravity (1.8 g), and microgravity (0.0 g) conditions induced in the prone and upright positions. Differences in spinal stiffness were significant across all three gravity conditions in the prone and upright positions. Most effect sizes were large; however, in the upright posture, the effect size between Earth gravity and microgravity was medium. Significant differences in spinal stiffness between the prone and upright positions were found during Earth gravity and hypergravity conditions. No difference was found between the two postures during microgravity conditions. Based on repeated measurements of a single individual, our results showed detectable changes in posterior-to-anterior spinal stiffness. Spinal stiffness increased during microgravity and decreased during hypergravity conditions. In microgravity conditions, posture did not impact spinal stiffness. More data on spinal stiffness in variable gravitational conditions is needed to confirm these results.Swanenburg J, Meier ML, Langenfeld A, Schweinhardt P, Humphreys BK. Spinal stiffness in prone and upright postures during 0-1.8 g induced by parabolic flight. Aerosp Med Hum Perform. 2018; 89(6):563-567.

  7. Inverse relationship between physical activity and arterial stiffness in adults with hypertension.

    Science.gov (United States)

    O'Donovan, Cuisle; Lithander, Fiona E; Raftery, Tara; Gormley, John; Mahmud, Azra; Hussey, Juliette

    2014-02-01

    Physical activity has beneficial effects on arterial stiffness among healthy adults. There is a lack of data on this relationship in adults with hypertension. The majority of studies which have examined physical activity and arterial stiffness have used subjective measures of activity. The aim of this study was to investigate the relationship between objectively measured habitual physical activity and arterial stiffness in individuals with newly diagnosed essential hypertension. Adults attending an outpatient hypertension clinic were recruited into this cross sectional study. Physical activity was measured using a triaxial accelerometer. Pulse wave velocity (PWV) and augmentation index (AIx) were measured using applanation tonometry. Participant's full lipid profile and glucose were determined through the collection of a fasting blood sample. Fifty-three adults [51(14) years, 26 male] participated, 16 of whom had the metabolic syndrome. Inactivity was positively correlated with PWV (r = .53, P arterial stiffness among adults with hypertension.

  8. Cardiovascular Health and Arterial Stiffness: The Maine Syracuse Longitudinal Study

    Science.gov (United States)

    Crichton, Georgina E; Elias, Merrill F; Robbins, Michael A

    2014-01-01

    Ideal cardiovascular health is a recently defined construct by the American Heart Association (AHA) to promote cardiovascular disease reduction. Arterial stiffness is a major risk factor for cardiovascular disease. The extent to which the presence of multiple prevalent cardiovascular risk factors and health behaviors is associated with arterial stiffness is unknown. The aim of this study was to examine the association between the AHA construct of cardiovascular health and arterial stiffness, as indexed by pulse wave velocity and pulse pressure. The AHA health metrics, comprising of four health behaviors (smoking, body mass index, physical activity, and diet) and three health factors (total cholesterol, blood pressure, and fasting plasma glucose) were evaluated among 505 participants in the Maine-Syracuse Longitudinal Study. Outcome measures were carotid-femoral pulse wave velocity (PWV) and pulse pressure measured at 4 to 5-year follow-up. Better cardiovascular health, comprising both health factors and behaviors, was associated with lower arterial stiffness, as indexed by pulse wave velocity and pulse pressure. Those with at least five health metrics at ideal levels had significantly lower PWV (9.8 m/s) than those with two or less ideal health metrics (11.7 m/s) (P<0.001). This finding remained with the addition of demographic and PWV-related variables (P=0.004). PMID:24384629

  9. Influence of Passive Joint Stiffness on Proprioceptive Acuity in Individuals With Functional Instability of the Ankle.

    Science.gov (United States)

    Marinho, Hellen Veloso Rocha; Amaral, Giovanna Mendes; de Souza Moreira, Bruno; Araújo, Vanessa Lara; Souza, Thales Rezende; Ocarino, Juliana Melo; da Fonseca, Sérgio Teixeira

    2017-12-01

    Study Design Controlled laboratory study, cross-sectional. Background Deficits in ankle proprioceptive acuity have been reported in persons with functional instability of the ankle. Passive stiffness has been proposed as a possible mechanism underlying proprioceptive acuity. Objective To compare proprioceptive acuity and passive ankle stiffness in persons with and without functional ankle instability, and to assess the influence of passive joint stiffness on proprioceptive acuity in persons with functional ankle instability. Methods A sample of 18 subjects with and 18 without complaints of functional ankle instability following lateral ankle sprain participated. An isokinetic dynamometer was used to compare motion perception threshold, passive position sense, and passive ankle stiffness between groups. To evaluate the influence of passive stiffness on proprioceptive acuity, individuals in the lateral functional ankle instability group were divided into 2 subgroups: "high" and "low" passive ankle stiffness. Results The functional ankle instability group exhibited increased motion perception threshold when compared with the corresponding limb of the control group. Between-group differences were not found for passive position sense and passive ankle stiffness. Those in the functional ankle instability group with higher passive ankle stiffness had smaller motion perception thresholds than those with lower passive ankle stiffness. Conclusion Unlike motion perception threshold, passive position sense is not affected by the presence of functional ankle instability. Passive ankle stiffness appears to influence proprioceptive acuity in persons with functional ankle instability. J Orthop Sports Phys Ther 2017;47(12):899-905. Epub 7 Oct 2017. doi:10.2519/jospt.2017.7030.

  10. Dynamic behavior of ultra large graphene-based membranes using electrothermal transduction

    Science.gov (United States)

    Al-mashaal, A. K.; Wood, G. S.; Torin, A.; Mastropaolo, E.; Newton, M. J.; Cheung, R.

    2017-12-01

    This letter reports an experimental study of an electrothermal actuator made from an ultra-large graphene-based bilayer thin film with a diameter to thickness aspect ratio of ˜10 000. Suspended thin films consisting of multilayer graphene and 350-500 nm-thick Poly(methyl methacrylate) have been transferred over circular cavities with a diameter of 3.5 mm. The use of bilayer materials with different mechanical and thermal properties results in thin film structures that can be induced to vibrate mechanically under the electrothermal transduction mechanism. The dynamic response of the bilayer has been investigated electrothermally by driving the structures with a combination of alternating current and direct current actuation voltages ( Va c and Vd c) and characterizing their resonant frequencies. It has been found that the bilayer thin film structure behaves as a membrane. In addition, the actuation configurations affect not only the amplitude of vibration but also the tuning of the resonant frequency of the vibrating membranes. The existence of Joule heating-induced tension lowers the mechanical stiffness of the membrane and hence shifts the resonant frequency downwards by -108187 ppm. A resonant frequency of 3.26 kHz with a vibration amplitude of 4.34 nm has been achieved for 350 nm-thick membranes under actuation voltages of 1 V of Va c and 8 V of Vd c.

  11. Increased muscle belly and tendon stiffness in patients with Parkinson's disease, as measured by myotonometry.

    Science.gov (United States)

    Marusiak, Jarosław; Jaskólska, Anna; Budrewicz, Sławomir; Koszewicz, Magdalena; Jaskólski, Artur

    2011-09-01

    Based on Davis's law, greater tonus of the muscle belly in individuals with Parkinson's disease can create greater tension in the tendon, leading to structural adjustment and an increase in tendon stiffness. Our study aimed to separately assess passive stiffness in the muscle belly and tendon in medicated patients with Parkinson's disease, using myotonometry. We tested 12 patients with Parkinson's disease and 12 healthy matched controls. Passive stiffness of muscle belly and tendon was estimated by myotonometry, electromyography, and mechanomyography in relaxed biceps and triceps brachii muscles. Compared with controls, patients with Parkinson's disease had higher stiffness in the muscle belly and tendon of the biceps brachii and in the tendon of the triceps brachii. In patients with Parkinson's disease, there was a positive correlation between muscle belly stiffness and parkinsonian rigidity in the biceps brachii. Patients with Parkinson's disease have higher passive stiffness of the muscle belly and tendon than healthy matched controls. Copyright © 2011 Movement Disorder Society.

  12. Mass and stiffness calibration of nanowires using thermally driven vibration

    International Nuclear Information System (INIS)

    Kiracofe, D R; Raman, A; Yazdanpanah, M M

    2011-01-01

    Cantilevered or suspended nanowires show promise for force or mass sensing applications due to their small mass, high force sensitivity and high frequency bandwidth. To use these as quantitative sensors, their bending stiffness or mass must be calibrated experimentally, often using thermally driven vibration. However, this can be difficult because nanowires are slightly asymmetric, which results in two spatially orthogonal bending eigenmodes with closely spaced frequencies. This asymmetry presents problems for traditional stiffness calibration methods, which equate the measured thermal vibration spectrum near a resonance to that of a single eigenmode. Moreover, the principal axes may be arbitrarily rotated with respect to the measurement direction. In this work, the authors propose a method for calibrating the bending stiffness and mass of such nanowires' eigenmodes using a single measurement taken at an arbitrary orientation with respect to the principal axes.

  13. The effects of resistance exercise training on arterial stiffness in metabolic syndrome.

    Science.gov (United States)

    DeVallance, E; Fournier, S; Lemaster, K; Moore, C; Asano, S; Bonner, D; Donley, D; Olfert, I M; Chantler, P D

    2016-05-01

    Arterial stiffness is a strong independent risk factor for cardiovascular disease and is elevated in individuals with metabolic syndrome (MetS). Resistance training is a popular form of exercise that has beneficial effects on muscle mass, strength, balance and glucose control. However, it is unknown whether resistance exercise training (RT) can lower arterial stiffness in patients with MetS. Thus, the aim of this study was to examine whether a progressive RT program would improve arterial stiffness in MetS. A total of 57 subjects (28 healthy sedentary subjects; 29 MetS) were evaluated for arterial structure and function, including pulse wave velocity (cfPWV: arterial stiffness), before and after an 8-week period of RT or continuation of sedentary lifestyle. We found that 8 weeks of progressive RT increased skeletal muscle strength in both Con and MetS, but did not change arterial stiffness in either MetS (cfPWV; Pre 7.9 ± 0.4 m/s vs. Post 7.7 ± 0.4 m/s) or healthy controls (cfPWV; Pre 6.9 ± 0.3 m/s vs. Post 7.0 ± 0.3 m/s). However, when cfPWV is considered as a continuous variable, high baseline measures of cfPWV tended to show a decrease in cfPWV following RT. Eight weeks of progressive RT did not decrease the group mean values of arterial stiffness in individuals with MetS or healthy controls.

  14. Effect of chain stiffness on the structure of single-chain polymer nanoparticles

    Science.gov (United States)

    Moreno, Angel J.; Bacova, Petra; Lo Verso, Federica; Arbe, Arantxa; Colmenero, Juan; Pomposo, José A.

    2018-01-01

    Polymeric single-chain nanoparticles (SCNPs) are soft nano-objects synthesized by purely intramolecular cross-linking of single polymer chains. By means of computer simulations, we investigate the conformational properties of SCNPs as a function of the bending stiffness of their linear polymer precursors. We investigate a broad range of characteristic ratios from the fully flexible case to those typical of bulky synthetic polymers. Increasing stiffness hinders bonding of groups separated by short contour distances and increases looping over longer distances, leading to more compact nanoparticles with a structure of highly interconnected loops. This feature is reflected in a crossover in the scaling behaviour of several structural observables. The scaling exponents change from those characteristic for Gaussian chains or rings in θ-solvents in the fully flexible limit, to values resembling fractal or ‘crumpled’ globular behaviour for very stiff SCNPs. We characterize domains in the SCNPs. These are weakly deformable regions that can be seen as disordered analogues of domains in disordered proteins. Increasing stiffness leads to bigger and less deformable domains. Surprisingly, the scaling behaviour of the domains is in all cases similar to that of Gaussian chains or rings, irrespective of the stiffness and degree of cross-linking. It is the spatial arrangement of the domains which determines the global structure of the SCNP (sparse Gaussian-like object or crumpled globule). Since intramolecular stiffness can be varied through the specific chemistry of the precursor or by introducing bulky side groups in its backbone, our results propose a new strategy to tune the global structure of SCNPs.

  15. The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness.

    Science.gov (United States)

    Shepherd, Max K; Rouse, Elliott J

    2017-12-01

    Most commercially available prosthetic feet do not exhibit a biomimetic torque-angle relationship, and are unable to modulate their mechanics to assist with other mobility tasks, such as stairs and ramps. In this paper, we present a quasi-passive ankle-foot prosthesis with a customizable torque-angle curve and an ability to quickly modulate ankle stiffness between tasks. The customizable torque-angle curve is obtained with a cam-based transmission and a fiberglass leaf spring. To achieve variable stiffness, the leaf spring's support conditions can be actively modulated by a small motor, shifting the torque-angle curve to be more or less stiff. We introduce the design, characterize the available torque-angle curves, and present kinematics from a transtibial amputee subject performing level-ground walking, stair ascent/descent, and ramp ascent/descent. The subject exhibited a more normative range of motion on stairs and ramps at lower stiffness levels, and preferred different stiffness levels for each task. Paired with an appropriate intent recognition system, our novel ankle prosthesis could improve gait biomechanics during walking and many other mobility tasks.

  16. Influence of Pre-Storage Irradiation on the Oxidative Stress Markers, Membrane Integrity, Size and Shape of the Cold Stored Red Blood Cells.

    Science.gov (United States)

    Antosik, Adam; Czubak, Kamila; Gajek, Arkadiusz; Marczak, Agnieszka; Glowacki, Rafal; Borowczyk, Kamila; Zbikowska, Halina Malgorzata

    2015-05-01

    To investigate the extent of oxidative damage and changes in morphology of manually isolated red blood cells (RBCs) from whole blood, cold stored (up to 20 days) in polystyrene tubes and subjected to pre-storage irradiation (50 Gy) and to compare the properties of SAGM-preserved RBCs stored under experimental conditions (polystyrene tubes) with RBCs from standard blood bag storage. The percentage of hemolysis as well as the extracellular activity of LDH, thiobarbituric acid-reactive substances, reduced glutathione (GSH), and total antioxidant capacity (TAC) were measured. Changes in the topology of RBC membrane, shape, and size were evaluated by flow cytometry and judged against microscopy images. Irradiation caused significant LDH release as well as increased hemolysis and lipid peroxidation, GSH depletion, and reduction of TAC. Prolonged storage of irradiated RBCs resulted in phosphatidylserine exposure on the cell surface. By day 20, approximately 60% of RBCs displayed non-discoid shape. We did not notice significant differences in percentage of altered cells and cell volume between RBCs exposed to irradiation and those not exposed. Irradiation of RBC transfusion units with a dose of 50 Gy should be avoided. For research purposes such as studying the role of antioxidants, storage of small volumes of RBCs derived from the same donor would be more useful, cheaper, and blood-saving.

  17. The Variable Stiffness Actuator vsaUT-II: Mechanical Design, Modeling, and Identification

    NARCIS (Netherlands)

    Groothuis, Stefan; Rusticelli, Giacomo; Zucchelli, Andrea; Stramigioli, Stefano; Carloni, Raffaella

    In this paper, the rotational variable stiffness actuator vsaUT-II is presented. This actuation system is characterized by the property that the apparent stiffness at the actuator output can be varied independently from its position. This behavior is realized by implementing a variable transmission

  18. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    Science.gov (United States)

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  19. Breast tissue stiffness estimation for surgical guidance using gravity-induced excitation.

    Science.gov (United States)

    Griesenauer, Rebekah H; Weis, Jared A; Arlinghaus, Lori R; Meszoely, Ingrid M; Miga, Michael I

    2017-06-21

    Tissue stiffness interrogation is fundamental in breast cancer diagnosis and treatment. Furthermore, biomechanical models for predicting breast deformations have been created for several breast cancer applications. Within these applications, constitutive mechanical properties must be defined and the accuracy of this estimation directly impacts the overall performance of the model. In this study, we present an image-derived computational framework to obtain quantitative, patient specific stiffness properties for application in image-guided breast cancer surgery and interventions. The method uses two MR acquisitions of the breast in different supine gravity-loaded configurations to fit mechanical properties to a biomechanical breast model. A reproducibility assessment of the method was performed in a test-retest study using healthy volunteers and was further characterized in simulation. In five human data sets, the within subject coefficient of variation ranged from 10.7% to 27% and the intraclass correlation coefficient ranged from 0.91-0.944 for assessment of fibroglandular and adipose tissue stiffness. In simulation, fibroglandular content and deformation magnitude were shown to have significant effects on the shape and convexity of the objective function defined by image similarity. These observations provide an important step forward in characterizing the use of nonrigid image registration methodologies in conjunction with biomechanical models to estimate tissue stiffness. In addition, the results suggest that stiffness estimation methods using gravity-induced excitation can reliably and feasibly be implemented in breast cancer surgery/intervention workflows.

  20. A case of stiff-person syndrome due to secondary adrenal insufficiency.

    Science.gov (United States)

    Mizuno, Yuri; Yamaguchi, Hiroo; Uehara, Taira; Yamashita, Kenichiro; Yamasaki, Ryo; Kira, Jun-Ichi

    2017-06-28

    We report a case of flexion contractures in a patient's legs secondary to postpartum hypopituitarism. A 56-year-old woman presented with a 3-year history of worsening flexion contractures of the hips and knees. On admission, her hips and knees could not be extended, and she had muscle stiffness and tenderness to palpation of the lower extremities. We first suspected stiff-person syndrome or Isaacs' syndrome because of her muscle stiffness. However, multiple hormones did not respond to stimulation tests, and an MRI of the brain showed atrophy of the pituitary gland with an empty sella. A subsequent interview revealed that she had suffered a severe hemorrhage while delivering her third child. She was diagnosed with panhypopituitarism and started on cortisol replacement therapy. After 1 week of treatment with hydrocortisone (10 mg/day), her symptoms quickly improved. We then added 75 μg/day of thyroid hormone. During the course of her treatment, autoantibodies against VGKC complex were found to be weakly positive. However, we considered the antibodies to be unrelated to her disease, because her symptoms improved markedly with low-dose steroid treatment. There are a few reports describing flexion contractures of the legs in patients with primary and secondary adrenal insufficiency. As these symptoms are similar to those seen in stiff-person syndrome, adrenal and pituitary insufficiency should be taken into account to achieve the correct diagnosis and treatment in patients with flexion contractures and muscle stiffness.

  1. Breast tissue stiffness estimation for surgical guidance using gravity-induced excitation

    Science.gov (United States)

    Griesenauer, Rebekah H.; Weis, Jared A.; Arlinghaus, Lori R.; Meszoely, Ingrid M.; Miga, Michael I.

    2017-06-01

    Tissue stiffness interrogation is fundamental in breast cancer diagnosis and treatment. Furthermore, biomechanical models for predicting breast deformations have been created for several breast cancer applications. Within these applications, constitutive mechanical properties must be defined and the accuracy of this estimation directly impacts the overall performance of the model. In this study, we present an image-derived computational framework to obtain quantitative, patient specific stiffness properties for application in image-guided breast cancer surgery and interventions. The method uses two MR acquisitions of the breast in different supine gravity-loaded configurations to fit mechanical properties to a biomechanical breast model. A reproducibility assessment of the method was performed in a test-retest study using healthy volunteers and was further characterized in simulation. In five human data sets, the within subject coefficient of variation ranged from 10.7% to 27% and the intraclass correlation coefficient ranged from 0.91-0.944 for assessment of fibroglandular and adipose tissue stiffness. In simulation, fibroglandular content and deformation magnitude were shown to have significant effects on the shape and convexity of the objective function defined by image similarity. These observations provide an important step forward in characterizing the use of nonrigid image registration methodologies in conjunction with biomechanical models to estimate tissue stiffness. In addition, the results suggest that stiffness estimation methods using gravity-induced excitation can reliably and feasibly be implemented in breast cancer surgery/intervention workflows.

  2. Effect of moisture absorption on damping and dynamic stiffness of carbon fiber/epoxy composites

    Energy Technology Data Exchange (ETDEWEB)

    Zai, Behzad Ahmed; Park, M. K.; Mehboob, Hassan; Ali, Rashid [Myongji University, Yongin (Korea, Republic of); Choi, H. S. [Korean Air Daejeon (Korea, Republic of)

    2009-11-15

    In this paper, the damping and dynamic stiffness of UHN125C carbon fiber/epoxy composite beam was experimentally measured. The effect of fiber orientation angle and stacking sequences on damping, resonance frequency, and dynamic stiffness was discussed with a focus on the effect of moisture absorption. Dried specimens were immersed in distilled water for a certain period to absorb water for 8, 16, and 24 d, respectively, and the moisture content absorbed in the specimen was measured. Furthermore, using the impact hammer technique, the measurements of dynamic responses were conducted on a cantilever beam specimen with one end clamped by bolts and metal plates. The damping properties in terms of loss factor were approximated by half-power bandwidth technique. The dynamic stiffness was evaluated using resonance frequency as a function of moisture content. The damping increased with the increase of moisture content: however, the dynamic stiffness reduced with the reduction of resonance frequency. The results of the dynamic stiffness were aided by measuring the dynamic strain using DBU-120A strain-indicating software. The increment in the dynamic strain strengthened the results obtained for dynamic stiffness

  3. Micromechanical contact stiffness devices and application for calibrating contact resonance atomic force microscopy

    Science.gov (United States)

    Rosenberger, Matthew R.; Chen, Sihan; Prater, Craig B.; King, William P.

    2017-01-01

    This paper reports the design, fabrication, and characterization of micromechanical devices that can present an engineered contact stiffness to an atomic force microscope (AFM) cantilever tip. These devices allow the contact stiffness between the AFM tip and a substrate to be easily and accurately measured, and can be used to calibrate the cantilever for subsequent mechanical property measurements. The contact stiffness devices are rigid copper disks of diameters 2-18 μm integrated onto a soft silicone substrate. Analytical modeling and finite element simulations predict the elastic response of the devices. Measurements of tip-sample interactions during quasi-static force measurements compare well with modeling simulation, confirming the expected elastic response of the devices, which are shown to have contact stiffness 32-156 N m-1. To demonstrate one application, we use the disk sample to calibrate three resonant modes of a U-shaped AFM cantilever actuated via Lorentz force, at approximately 220, 450, and 1200 kHz. We then use the calibrated cantilever to determine the contact stiffness and elastic modulus of three polymer samples at these modes. The overall approach allows cantilever calibration without prior knowledge of the cantilever geometry or its resonance modes, and could be broadly applied to both static and dynamic measurements that require AFM calibration against a known contact stiffness.

  4. Whole-body vibration as a potential countermeasure for dynapenia and arterial stiffness

    Directory of Open Access Journals (Sweden)

    Arturo Figueroa

    2016-09-01

    Full Text Available Age-related decreases in muscle mass and strength are associated with decreased mobility, quality of life, and increased cardiovascular risk. Coupled with the prevalence of obesity, the risk of death becomes substantially greater. Resistance training (RT has a well-documented beneficial impact on muscle mass and strength in young and older adults, although the high-intensity needed to elicit these adaptations may have a detrimental or negligible impact on vascular function, specifically on arterial stiffness. Increased arterial stiffness is associated with systolic hypertension, left ventricular hypertrophy, and myocardial ischemia. Therefore, improvements of muscle strength and arterial function are important in older adults. Recently, whole-body vibration (WBV exercise, a novel modality of strength training, has shown to exhibit similar results on muscle strength as RT in a wide-variety of populations, with the greatest impact in elderly individuals with limited muscle function. Additionally, WBV training has been shown to have beneficial effects on vascular function by reducing arterial stiffness. This article reviews relevant publications reporting the effects of WBV on muscle strength and/or arterial stiffness. Findings from current studies suggest the use of WBV training as an alternative modality to traditional RT to countermeasure the age-related detriments in muscle strength and arterial stiffness in older adults.

  5. Whole-body vibration as a potential countermeasure for dynapenia and arterial stiffness.

    Science.gov (United States)

    Figueroa, Arturo; Jaime, Salvador J; Alvarez-Alvarado, Stacey

    2016-09-01

    Age-related decreases in muscle mass and strength are associated with decreased mobility, quality of life, and increased cardiovascular risk. Coupled with the prevalence of obesity, the risk of death becomes substantially greater. Resistance training (RT) has a well-documented beneficial impact on muscle mass and strength in young and older adults, although the high-intensity needed to elicit these adaptations may have a detrimental or negligible impact on vascular function, specifically on arterial stiffness. Increased arterial stiffness is associated with systolic hypertension, left ventricular hypertrophy, and myocardial ischemia. Therefore, improvements of muscle strength and arterial function are important in older adults. Recently, whole-body vibration (WBV) exercise, a novel modality of strength training, has shown to exhibit similar results on muscle strength as RT in a wide-variety of populations, with the greatest impact in elderly individuals with limited muscle function. Additionally, WBV training has been shown to have beneficial effects on vascular function by reducing arterial stiffness. This article reviews relevant publications reporting the effects of WBV on muscle strength and/or arterial stiffness. Findings from current studies suggest the use of WBV training as an alternative modality to traditional RT to countermeasure the age-related detriments in muscle strength and arterial stiffness in older adults.

  6. Effect of upper body position on arterial stiffness: influence of hydrostatic pressure and autonomic function.

    Science.gov (United States)

    Schroeder, Elizabeth C; Rosenberg, Alexander J; Hilgenkamp, Thessa I M; White, Daniel W; Baynard, Tracy; Fernhall, Bo

    2017-12-01

    To evaluate changes in arterial stiffness with positional change and whether the stiffness changes are due to hydrostatic pressure alone or if physiological changes in vasoconstriction of the conduit arteries play a role in the modulation of arterial stiffness. Thirty participants' (male = 15, 24 ± 4 years) upper bodies were positioned at 0, 45, and 72° angles. Pulse wave velocity (PWV), cardio-ankle vascular index, carotid beta-stiffness index, carotid blood pressure (cBP), and carotid diameters were measured at each position. A gravitational height correction was determined using the vertical fluid column distance (mmHg) between the heart and carotid artery. Carotid beta-stiffness was calibrated using three methods: nonheight corrected cBP of each position, height corrected cBP of each position, and height corrected cBP of the supine position (theoretical model). Low frequency systolic blood pressure variability (LFSAP) was analyzed as a marker of sympathetic activity. PWV and cardio-ankle vascular index increased with position (P hydrostatic pressure. Arterial stiffness indices based on Method 2 were not different from Method 3 (P = 0.65). LFSAP increased in more upright positions (P pressure did not (P > 0.05). Arterial stiffness increases with a more upright body position. Carotid beta-stiffness needs to be calibrated accounting for hydrostatic effects of gravity if measured in a seated position. It is unclear why PWV increased as this increase was independent of blood pressure. No difference between Methods 2 and 3 presumably indicates that the beta-stiffness increases are only pressure dependent, despite the increase in vascular sympathetic modulation.

  7. The role of red blood cell deformability and Na,K-ATPase function in selected risk factors of cardiovascular diseases in humans: focus on hypertension, diabetes mellitus and hypercholesterolemia.

    Science.gov (United States)

    Radosinska, J; Vrbjar, N

    2016-09-19

    Deformability of red blood cells (RBC) is the ability of RBC to change their shape in order to pass through narrow capillaries in circulation. Deterioration in deformability of RBC contributes to alterations in microcirculatory blood flow and delivery of oxygen to tissues. Several factors are responsible for maintenance of RBC deformability. One of them is the Na,K-ATPase known as crucial enzyme in maintenance of intracellular ionic homeostasis affecting thus regulation of cellular volume and consequently RBC deformability. Decreased deformability of RBC has been found to be the marker of adverse outcomes in cardiovascular diseases (CVD) and the presence of cardiovascular risk factors influences rheological properties of the blood. This review summarizes knowledge concerning the RBC deformability in connection with selected risk factors of CVD, including hypertension, hyperlipidemia, and diabetes mellitus, based exclusively on papers from human studies. We attempted to provide an update on important issues regarding the role of Na,K-ATPase in RBC deformability. In patients suffering from hypertension as well as diabetes mellitus the Na,K-ATPase appears to be responsible for the changes leading to alterations in RBC deformability. The triggering factor for changes of RBC deformability during hypercholesterolemia seems to be the increased content of cholesterol in erythrocyte membranes.

  8. Experimental Investigation of Stiffness Characteristics and Damping Properties of a Metallic Rubber Material

    Science.gov (United States)

    Lu, Ch. Zh.; Li, Jingyuan; Zhou, Bangyang; Li, Shuang

    2017-09-01

    The static stiffness and dynamic damping properties of a metallic rubber material (MR) were investigated, which exhibited a nonlinear deformation behavior. Its static stiffness is analyzed and discussed. The effects of structural parameters of MR and experimental conditions on its shock absorption capacity were examined by dynamic tests. Results revealed excellent elastic and damping properties of the material. Its stiffness increased with density, but decreased with thickness. The damping property of MR varied with its density, thickness, loading frequency, and amplitude.

  9. [Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study].

    Science.gov (United States)

    Buchvald, P; Čapek, L; Barsa, P

    2015-01-01

    PURPOSE OF THE STUDY The aim of the experiment was to compare the bending stiffness of an intact odontoid process with bending stiffness after its simulated type II fracture was fixed with a single lag screw. The experiment was done with a desire to answer the question of whether a single osteosynthetic screw is sufficient for good fixation of a type II odontoid fracture. MATERIAL AND METHODS The C2 vertebrae of six cadavers were used. With simultaneous measurement of odontoid bending stiffness, the occurrence of a fracture (type IIA, Grauer's modification of the Anderson- D'Alonzo classification) was simulated using action exerted by a tearing machine in the direction perpendicular to the odontoid axis. Each odontoid fracture was subsequently treated by direct osteosynthesis with a single lag screw inserted in the axial direction by a standard surgical procedure in order to provide conditions similar to those achieved by routine surgical management. The treated odontoid process was subsequently subjected to the same tearing machine loading as applied to it at the start of the experiment. The bending stiffness measured was then compared with that found before the fracture occurred. The results were statistically evaluated by the t-test for paired samples at the level of significance α = 0.05. RESULTS The average value of bending stiffness for odontoid processes of intact vertebrae at the moment of fracture occurrence was 318.3 N/mm. After single axial lag screw fixation of the fracture, the average bending stiffness for the odontoid processes treated was 331.3 N/mm. DISCUSSION Higher values of bending stiffness after screw fixation were found in all specimens and, in comparison with the values recorded before simulated fractures, the increase was statistically significant. CONCLUSIONS The results of our measurements suggest that the single lag screw fixation of a type IIA odontoid fracture will provide better stability for the fracture fragment-C2 body complex on

  10. Variant Exported Blood-Stage Proteins Encoded by Plasmodium Multigene Families Are Expressed in Liver Stages Where They Are Exported into the Parasitophorous Vacuole.

    Directory of Open Access Journals (Sweden)

    Aurélie Fougère

    2016-11-01

    Full Text Available Many variant proteins encoded by Plasmodium-specific multigene families are exported into red blood cells (RBC. P. falciparum-specific variant proteins encoded by the var, stevor and rifin multigene families are exported onto the surface of infected red blood cells (iRBC and mediate interactions between iRBC and host cells resulting in tissue sequestration and rosetting. However, the precise function of most other Plasmodium multigene families encoding exported proteins is unknown. To understand the role of RBC-exported proteins of rodent malaria parasites (RMP we analysed the expression and cellular location by fluorescent-tagging of members of the pir, fam-a and fam-b multigene families. Furthermore, we performed phylogenetic analyses of the fam-a and fam-b multigene families, which indicate that both families have a history of functional differentiation unique to RMP. We demonstrate for all three families that expression of family members in iRBC is not mutually exclusive. Most tagged proteins were transported into the iRBC cytoplasm but not onto the iRBC plasma membrane, indicating that they are unlikely to play a direct role in iRBC-host cell interactions. Unexpectedly, most family members are also expressed during the liver stage, where they are transported into the parasitophorous vacuole. This suggests that these protein families promote parasite development in both the liver and blood, either by supporting parasite development within hepatocytes and erythrocytes and/or by manipulating the host immune response. Indeed, in the case of Fam-A, which have a steroidogenic acute regulatory-related lipid transfer (START domain, we found that several family members can transfer phosphatidylcholine in vitro. These observations indicate that these proteins may transport (host phosphatidylcholine for membrane synthesis. This is the first demonstration of a biological function of any exported variant protein family of rodent malaria parasites.

  11. Specific adaptations of neuromuscular control and knee joint stiffness following sensorimotor training.

    Science.gov (United States)

    Gruber, M; Bruhn, S; Gollhofer, A

    2006-08-01

    The aim of this study was to examine how fixations of the ankle joint during sensorimotor training (SMT) influence adaptations in mechanical stiffness and neuromuscular control of the knee joint. Sixty-three healthy subjects were randomly assigned to three training groups that differed in their degree of ankle joint fixation, which was either barefooted, with an ankle brace or with a ski boot. Mechanical knee joint stiffness and reflex control of m. vastus medialis, m. vastus lateralis, m. biceps femoris, and m. semitendinosus were tested during force controlled anterior tibial displacements. This force was applied as both a fast and a slow stimulus. After the training period the group that trained barefooted showed an increase in mechanical stiffness of the knee joint from 79 +/- 21 (Mean +/- SD) N/mm to 110 +/- 38 N/mm (p boots was able to improve knee joint stiffness from 67 +/- 26 N/mm to 96 +/- 47 N/mm (p knee joint injuries.

  12. Development of membrane mechanical function during terminal stages of primitive erythropoiesis in mice.

    Science.gov (United States)

    Waugh, Richard E; Huang, Yu-Shan; Arif, Binish J; Bauserman, Richard; Palis, James

    2013-04-01

    During murine embryogenesis, primitive erythroblasts enter the circulation as immature nucleated cells and progressively mature as a semisynchronous cohort, enucleating between E12.5 and E16.5. In this report, we examine the mechanical properties of these cells to determine how their mechanical development differs from that of definitive erythroid cells, which mature extravascularly in protected marrow microenvironments. Primitive erythroid cells acquire normal membrane deformability by E12.5 (i.e., as late stage erythroblasts) and maintain the same level of surface stiffness through E17.5. During this same period, the strength of association between the membrane bilayer and the underlying skeleton increases, as indicated by an approximate doubling of the energy required to separate bilayer from skeleton. At the same time, these cells undergo dramatic changes in surface area and volume, losing 35% of their surface area and 50% of their volume from E14.5 to E17.5. Interestingly, membrane remodeling proceeded regardless of whether the cells completed enucleation. These data suggest that in primitive erythroid cells, unlike their definitive counterparts, the critical maturational processes of membrane remodeling and enucleation are uncoupled. Copyright © 2013 ISEH - Society for Hematology and Stem Cells. Published by Elsevier Inc. All rights reserved.

  13. Non-invasive evaluation of liver stiffness after splenectomy in rabbits with CCl4-induced liver fibrosis.

    Science.gov (United States)

    Wang, Ming-Jun; Ling, Wen-Wu; Wang, Hong; Meng, Ling-Wei; Cai, He; Peng, Bing

    2016-12-14

    To investigate the diagnostic performance of liver stiffness measurement (LSM) by elastography point quantification (ElastPQ) in animal models and determine the longitudinal changes in liver stiffness by ElastPQ after splenectomy at different stages of fibrosis. Liver stiffness was measured in sixty-eight rabbits with CCl 4 -induced liver fibrosis at different stages and eight healthy control rabbits by ElastPQ. Liver biopsies and blood samples were obtained at scheduled time points to assess liver function and degree of fibrosis. Thirty-one rabbits with complete data that underwent splenectomy at different stages of liver fibrosis were then included for dynamic monitoring of changes in liver stiffness by ElastPQ and liver function according to blood tests. LSM by ElastPQ was significantly correlated with histologic fibrosis stage ( r = 0.85, P fibrosis, moderate fibrosis, and cirrhosis, respectively. Longitudinal monitoring of the changes in liver stiffness by ElastPQ showed that early splenectomy (especially F1) may delay liver fibrosis progression. ElastPQ is an available, convenient, objective and non-invasive technique for assessing liver stiffness in rabbits with CCl 4 -induced liver fibrosis. In addition, liver stiffness measurements using ElastPQ can dynamically monitor the changes in liver stiffness in rabbit models, and in patients, after splenectomy.

  14. Ingesting a small amount of beer reduces arterial stiffness in healthy humans.

    Science.gov (United States)

    Nishiwaki, Masato; Kora, Naoki; Matsumoto, Naoyuki

    2017-08-01

    Epidemiological studies reveal a J-shaped association between alcohol consumption and arterial stiffness, with arterial stiffening lower among mild-to-moderate drinkers than heavy drinkers or nondrinkers. This study aimed to examine the effects of ingesting a small amount of beer, corresponding to the amount consumed per day by a mild drinker, on arterial stiffness. Eleven men (20-22 years) participated, in random order and on different days, in four separate trials. The participants each drank 200 or 350 mL of alcohol-free beer (AFB200 and AFB350) or beer (B200 and B350), and were monitored for 90 min postingestion. There were no significant changes in arterial stiffness among trials that ingested AF200 or AF350. However, among trials ingesting B200 and B350, breath alcohol concentrations increased significantly, while indexes of arterial stiffness decreased significantly for approximately 60 min: carotid-femoral pulse wave velocity (B200: -0.6 ± 0.2 m/sec; B350: -0.6 ± 0.2 m/sec); brachial-ankle pulse wave velocity (B200: -53 ± 18 cm/sec; B350: -57 ± 19 cm/sec); and cardio-ankle vascular index (B200: -0.4 ± 0.1 unit; B350: -0.3 ± 0.1 unit). Furthermore, AFB showed no effect on arterial stiffness, regardless of whether or not it contained sugar, and no significant difference in antioxidant capacity was found between AFB and B. This is the first study to demonstrate that acute ingestion of relatively small amounts of beer reduces arterial stiffness (for approximately 60 min). Our data also suggest that the reduction in arterial stiffness induced by ingestion of beer is largely attributable to the effects of alcohol. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  15. Custom 3D Printable Silicones with Tunable Stiffness.

    Science.gov (United States)

    Durban, Matthew M; Lenhardt, Jeremy M; Wu, Amanda S; Small, Ward; Bryson, Taylor M; Perez-Perez, Lemuel; Nguyen, Du T; Gammon, Stuart; Smay, James E; Duoss, Eric B; Lewicki, James P; Wilson, Thomas S

    2018-02-01

    Silicone elastomers have broad versatility within a variety of potential advanced materials applications, such as soft robotics, biomedical devices, and metamaterials. A series of custom 3D printable silicone inks with tunable stiffness is developed, formulated, and characterized. The silicone inks exhibit excellent rheological behavior for 3D printing, as observed from the printing of porous structures with controlled architectures. Herein, the capability to tune the stiffness of printable silicone materials via careful control over the chemistry, network formation, and crosslink density of the ink formulations in order to overcome the challenging interplay between ink development, post-processing, material properties, and performance is demonstrated. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Numerical investigation of the relationship between magnetic stiffness and minor loop size in the HTS levitation system

    Directory of Open Access Journals (Sweden)

    Yong Yang

    2017-10-01

    Full Text Available The effect of minor loop size on the magnetic stiffness has not been paid attention to by most researchers in experimental and theoretical studies about the high temperature superconductor (HTS magnetic levitation system. In this work, we numerically investigate the average magnetic stiffness obtained by the minor loop traverses Δz (or Δx varying from 0.1 mm to 2 mm in zero field cooling and field cooling regimes, respectively. The approximate values of the magnetic stiffness with zero traverse are obtained using the method of linear extrapolation. Compared with the average magnetic stiffness gained by any minor loop traverse, these approximate values are Not always close to the average magnetic stiffness produced by the smallest size of minor loops. The relative deviation ranges of average magnetic stiffness gained by the usually minor loop traverse (1 or 2 mm are presented by the ratios of approximate values to average stiffness for different moving processes and two typical cooling conditions. The results show that most of average magnetic stiffness are remarkably influenced by the sizes of minor loop, which indicates that the magnetic stiffness obtained by a single minor loop traverse Δz or Δx, for example, 1 or 2 mm, can be generally caused a large deviation.

  17. Comparative study of a muscle stiffness sensor and electromyography and mechanomyography under fatigue conditions.

    Science.gov (United States)

    Han, Hyonyoung; Jo, Sungho; Kim, Jung

    2015-07-01

    This paper proposes the feasibility of a stiffness measurement for muscle contraction force estimation under muscle fatigue conditions. Bioelectric signals have been widely studied for the estimation of the contraction force for physical human-robot interactions, but the correlation between the biosignal and actual motion is decreased under fatigue conditions. Muscle stiffness could be a useful contraction force estimator under fatigue conditions because it measures the same physical quantity as the muscle contraction that generates the force. Electromyography (EMG), mechanomyography (MMG), and a piezoelectric resonance-based active muscle stiffness sensor were used to analyze the biceps brachii under isometric muscle fatigue conditions with reference force sensors at the end of the joint. Compared to EMG and MMG, the change in the stiffness signal was smaller (p fatigue condition changed fatigue conditions. This result indicates that the muscle stiffness signal is less sensitive to muscle fatigue than other biosignals. This investigation provides insights into methods of monitoring and compensating for muscle fatigue.

  18. Use of the dynamic stiffness method to interpret experimental data from a nonlinear system

    Science.gov (United States)

    Tang, Bin; Brennan, M. J.; Gatti, G.

    2018-05-01

    The interpretation of experimental data from nonlinear structures is challenging, primarily because of dependency on types and levels of excitation, and coupling issues with test equipment. In this paper, the use of the dynamic stiffness method, which is commonly used in the analysis of linear systems, is used to interpret the data from a vibration test of a controllable compressed beam structure coupled to a test shaker. For a single mode of the system, this method facilitates the separation of mass, stiffness and damping effects, including nonlinear stiffness effects. It also allows the separation of the dynamics of the shaker from the structure under test. The approach needs to be used with care, and is only suitable if the nonlinear system has a response that is predominantly at the excitation frequency. For the structure under test, the raw experimental data revealed little about the underlying causes of the dynamic behaviour. However, the dynamic stiffness approach allowed the effects due to the nonlinear stiffness to be easily determined.

  19. An acoustic startle alters knee joint stiffness and neuromuscular control.

    Science.gov (United States)

    DeAngelis, A I; Needle, A R; Kaminski, T W; Royer, T R; Knight, C A; Swanik, C B

    2015-08-01

    Growing evidence suggests that the nervous system contributes to non-contact knee ligament injury, but limited evidence has measured the effect of extrinsic events on joint stability. Following unanticipated events, the startle reflex leads to universal stiffening of the limbs, but no studies have investigated how an acoustic startle influences knee stiffness and muscle activation during a dynamic knee perturbation. Thirty-six individuals were tested for knee stiffness and muscle activation of the quadriceps and hamstrings. Subjects were seated and instructed to resist a 40-degree knee flexion perturbation from a relaxed state. During some trials, an acoustic startle (50 ms, 1000 Hz, 100 dB) was applied 100 ms prior to the perturbation. Knee stiffness, muscle amplitude, and timing were quantified across time, muscle, and startle conditions. The acoustic startle increased short-range (no startle: 0.044 ± 0.011 N·m/deg/kg; average startle: 0.047 ± 0.01 N·m/deg/kg) and total knee stiffness (no startle: 0.036 ± 0.01 N·m/deg/kg; first startle 0.027 ± 0.02 N·m/deg/kg). Additionally, the startle contributed to decreased [vastus medialis (VM): 13.76 ± 33.6%; vastus lateralis (VL): 6.72 ± 37.4%] but earlier (VM: 0.133 ± 0.17 s; VL: 0.124 ± 0.17 s) activation of the quadriceps muscles. The results of this study indicate that the startle response can significantly disrupt knee stiffness regulation required to maintain joint stability. Further studies should explore the role of unanticipated events on unintentional injury. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Arterial Stiffness in Nonhypertensive Type 2 Diabetes Patients in Ghana

    Directory of Open Access Journals (Sweden)

    Kwame Yeboah

    2016-01-01

    Full Text Available Background. Increased arterial stiffness is an independent cardiovascular risk factor in diabetes patients and general population. However, the contribution of diabetes to arterial stiffness is often masked by coexistent obesity and hypertension. In this study, we assessed arterial stiffness in nonhypertensive, nonobese type 2 diabetes (T2DM patients in Ghana. Methods. In case-control design, 166 nonhypertensive, nonobese participants, comprising 96 T2DM patients and 70 nondiabetes controls, were recruited. Peripheral and central blood pressure (BP indices were measured, and arterial stiffness was assessed as aortic pulse wave velocity (PWVao, augmentation index (AIx, cardioankle vascular index (CAVI, and heart-ankle pulse wave velocity (haPWV. Results. With similar peripheral and central BP indices, T2DM patients had higher PWVao (8.3 ± 1 versus 7.8 ± 1.3, p=0.044 and CAVI (7.9 ± 1.2 versus 6.9 ± 0.7, p=0.021 than nondiabetic control. AIx and haPWV were similar between T2DM and nondiabetic controls. Multiple regression models showed that, in the entire study participants, the major determinants of PWVao were diabetes status, age, gender, systolic BP, and previous smoking status (β = 0.22, 0.36, 0.48, 0.21, and 0.25, resp.; all p<0.05; the determinants of CAVI were diabetes status, age, BMI, heart rate, HbA1c, total cholesterol, HDL cholesterol, and previous smoking status (β = 0.21, 0.38, 0.2, 0.18, 0.24. 0.2, −0.19, and 0.2, resp.; all p<0.05. Conclusion. Our findings suggest that nonhypertensive, nonobese T2DM patients have increased arterial stiffness without appreciable increase in peripheral and central pressure indices.