WorldWideScience

Sample records for rbc count haemoglobin

  1. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  2. Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error.

    Science.gov (United States)

    Chan, Leo Li-Ying; Laverty, Daniel J; Smith, Tim; Nejad, Parham; Hei, Hillary; Gandhi, Roopali; Kuksin, Dmitry; Qiu, Jean

    2013-02-28

    Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs

  3. Relationship of white blood cell counts, haemoglobin and ESR with IHD

    International Nuclear Information System (INIS)

    Shahzad, F.; Shahzad Tawwab, S.; Abbas, A.

    2009-01-01

    To find any association of white blood cells, haemoglobin and ESR with ischemic heart disease in high risk native population. Methodology: The study included 93 male patients with Ischemic heart disease, between 40 and 60 years of age; 96 age and gender matched subjects. All study participants were non-diabetics. Complete blood cells count, haemoglobin and ESR levels were compared between the patient and control groups. Results: Total leukocyte counts along with neutrophils were significantly higher in the test group compared to the control population (p<0.001) and lymphocytes were significantly lower (p<0.001) in the patient group as compared to the control group. Haemoglobin levels were significantly lower (p<0.001) and ESR was higher (p=0.030) in the patient group as compared to the control group. Conclusion: Although, our findings of the study variables extend previous reports, the prevalence and prognostic importance of theses variables in IHD should be assessed in future experimental studies. These parameters could be important in public health because they are routinely measured by clinicians and may be helpful to predict the risk of future and secondary ischemic events in a high risk population. (author)

  4. RBC nuclear scan

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  5. Antioxidant activity of citrullus colocynthis pulp extract in the RBC's of alloxan-induced diabetic rats

    International Nuclear Information System (INIS)

    Dallak, M.; Jaliah, B.I.

    2010-01-01

    Previous studies in our laboratory showed that Citrullus colocynthis pulp seedless extract have antihyperglycemic and insulinotropic effects in alloxan induced diabetes. Reactive oxygen species have been implicated in the mechanism of damage of red blood cells and anaemia in diabetic patients. So the current study was carried out to investigate the protective role of citrullus colocynthis against oxidative stress in the RBC's of alloxan induced diabetic rats. Methods: Rats were divided into four groups each of ten rats, the first group was normal non diabetic rats given normal saline orally and was named control group, the second group was diabetic rats given normal saline orally and were named normal saline treated-diabetic rats, the third and fourth group were diabetic rats treated with the pulp extract or glibenclamide (a positive control) orally. Evaluations were made for haematological parameters in the blood and for lipid peroxidation and oxidative stress enzymes activities in the RBC's of all experimental rats. Results: The diabetic rats had a significant decrease (p<0.05) in total erythrocytes count and Packed Cell Volume (PCV) and a normal Haemoglobin (Hb) value in the blood. They also showed decreased levels of Thiobarbituric Acid Reactive Substances (TBARS) and decreased activities of Superoxide Dismutase (SOD) and Catalase (CAT) in the RBC's hemolysate. On other hand, oral administration of citrullus colocynthis or glibenclamide alleviated these altered parameters in the treated rats, they resulted in a significant increase (p<0.05) in the in total erythrocytes count and PCV (Haematocrit) values in the blood and caused a significant decreased levels of TBARS and increased activities of SOD and CAT in the RBC's of those diabetic treated rats when compared to diabetic rats given normal saline. The effect was more profound in citrullus colocynthis treated diabetic rats. Conclusion: Citrullus colocynthis pulp extract possesses a potent antioxidant property

  6. Characterization of blood donors with high haemoglobin concentration

    DEFF Research Database (Denmark)

    Magnussen, K; Hasselbalch, H C; Ullum, H

    2013-01-01

    Background and Objectives  The literature contains little on the prevalence and causes of high predonation haemoglobin levels among blood donors. This study aimed to characterize and develop an algorithm to manage would-be donors with polycythaemia. Materials and Methods  Between November 2009...... and November 2011, we offered haematology consultations to blood donors with repeated haemoglobin concentration (Hb) above the WHO limit for polycythaemia vera (PV) (10·2 and 11·5 mm/16·5 and 18·5 g/dl for women and men, respectively). Investigation of such donors included Hb, haematocrit, mean cell volume......, erythropoietin, ferritin, platelet count and leucocyte count, JAK2 V617 and JAK2 exon12 analysis, as well as other routine measurements. Results  Among 46 such donors, 39 had a history of smoking, which contributes to erythrocytosis. Two had PV, five had severe hypertension, one of them because of renal artery...

  7. Haemoglobin Rahere (beta Lys-Thr): A new high affinity haemoglobin associated with decreased 2, 3-diphosphoglycerate binding and relative polycythaemia.

    Science.gov (United States)

    Lorkin, P A; Stephens, A D; Beard, M E; Wrigley, P F; Adams, L; Lehmann, H

    1975-01-01

    A new haemoglobin with increased oxygen affinity, beta82 (EF6) lysine leads to threonine (Hb Rahere), was found during the investigation of a patient who was found to have a raised haemoglobin concentration after a routine blood count. The substitution affects one of the 2, 3-diphosphoglycerate binding sites, resulting in an increased affinity for oxygen, but both the haem-haem interaction and the alkaline Bohr effect are normal in the haemolysate. This variant had the same mobility as haemoglobin A on electrophoresis at alkaline pH but was detected by measuring the whole blood oxygen affinity; it could be separated from haemoglobin A, however, by electrophoresis in agar at acid pH. The raised haemoglobin concentration was mainly due to a reduction in plasma volume (a relative polycythaemia) and was associated with a persistently raised white blood count. This case emphasises the need to measure the oxygen affinity of haemoglobin in all patients with absolute or relative polycythaemia when some obvious cause is not evident. PMID:124

  8. Aspirin-mediated acetylation of haemoglobin increases in presence of high glucose concentration and decreases protein glycation

    Directory of Open Access Journals (Sweden)

    Francesco Finamore

    2015-09-01

    Full Text Available Glycation represents the first stage in the development of diabetic complications. Aspirin was shown to prevent sugars reacting with proteins, but the exact mechanism of this interaction was not well defined. We performed a quantitative analysis to calculate the levels of acetylation and glycation of haemoglobin, among others red blood cell (RBC proteins, using a label free approach. After glucose incubation, increases in the acetylation levels were seen for several haemoglobin subunits, while a parallel decrease of their glycation levels was observed after aspirin incubation. These results suggest that, a mutual influence between these two modifications, occur at protein level.

  9. High activity antioxidant enzymes protect flying-fox haemoglobin against damage: an evolutionary adaptation for flight?

    Science.gov (United States)

    Reinke, N B; O'Brien, G M

    2006-11-01

    Flying-foxes are better able to defend haemoglobin against autoxidation than non-volant mammals such as sheep. When challenged with the common physiological oxidant, hydrogen peroxide, haemolysates of flying-fox red blood cells (RBC) were far less susceptible to methaemoglobin formation than sheep. Challenge with 1-acetyl-2-phenylhydrazine (APH) caused only half as much methaemoglobin formation in flying-fox as in ovine haemolysates. When intact cells were challenged with phenazine methosulfate (PMS), flying-fox RBC partially reversed the oxidant damage, and reduced methaemoglobin from 40 to 20% over 2 h incubation, while ovine methaemoglobin remained at 40%. This reflected flying-fox cells' capacity to replenish GSH fast enough that it did not deplete beyond 50%, while ovine RBC GSH was depleted to around 20%. The greater capacity of flying-foxes to defend haemoglobin against oxidant damage may be explained in part by antioxidant enzymes catalase, superoxide dismutase and cytochrome-b ( 5 ) reductase having two- to four-fold higher activity than in sheep (P foxes.

  10. Structure of the haptoglobin-haemoglobin complex

    DEFF Research Database (Denmark)

    Andersen, Christian Brix Folsted; Torvund-Jensen, Morten; Nielsen, Marianne Jensby

    2012-01-01

    to oxidative modification after exposure to haem-induced reactive oxygen species are buried in the haptoglobin-haemoglobin interface, thus showing a direct protective role of haptoglobin. The haptoglobin loop previously shown to be essential for binding of haptoglobin-haemoglobin to the macrophage scavenger...... that the rigid dimeric complex can bind two receptors. Such receptor cross-linkage may facilitate scavenging and explain the increased functional affinity of multimeric haptoglobin-haemoglobin for CD163 (ref. 4)....

  11. Bone disease in haemoglobin disorders

    Directory of Open Access Journals (Sweden)

    Ersi Voskaridou

    2013-03-01

    Full Text Available Bone disease represents a prominent cause of morbidity in patients with thalassaemia and other haemoglobin disorders. The delay in sexual maturation, the presence of diabetes and hypothyroidism, the parathyroid gland dysfunction, the haemolytic anaemia, the progressive marrow expansion, the iron toxicity on osteoblasts, the iron chelators, and the deficiency of growth hormone or insulin growth factors have been identified as major causes of osteoporosis in thalassaemia. Adequate hormonal replacement, effective iron chelation, improvement of hemoglobin levels, calcium and vitamin D administration, physical activity, and smoking cessation are the main to-date measures for the management of the disease. During the last decade, novel pathogenetic data suggest that the reduced osteoblastic activity, which is believed to be the basic mechanism of bone loss in thalassemia, is accompanied by a comparable or even greater increase in bone resorption. Therefore, potent inhibitors of osteoclast activation, such as the aminobisphosphonates, arise as key drugs for the management of osteoporosis in thalassaemia patients and other haemoglobin disorders.

  12. Experimental evaluation of mechanical and electrical properties of RBC suspensions under flow. Role of RBC deformability

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2010-01-01

    Roč. 25, 3-4 (2010), s. 45-52 ISSN 1313-2458 Institutional research plan: CEZ:AV0Z20600510 Keywords : apparent viscosity * conductivity * RBC suspensions * dextran 70 * PEG 35 000 * glutaraldehyde Subject RIV: BK - Fluid Dynamics

  13. In vivo crossmatching with Tc-99m-RBC's and In-111-oxine-RBC's

    International Nuclear Information System (INIS)

    Marcus, C.S.; Myhre, B.A.; Angulo, M.C.; Salk, R.D.; Essex, C.E.

    1984-01-01

    In vitro crossmatching techniques are often inadequate for patients who have received multiple prior transfusions. These patients usually have multiple antibodies to minor blood groups, not all of which are necessarily important to vivo. It becomes increasingly difficult to obtain appropriate units for transfusion, and often units are used with hopes that a minor group antibody will not be significantly active in vivo. If a transfusion reaction occurs, the unit is stopped. The authors have developed and successfully tested a method whereby 1.5 to 3c of potential donor RBC's are labeled with 25-50 μCi of Tc-99m using the BNL kits. After injection, samples are drawn at 10, 20, 60, and 120 minutes and the RBC survival is measured. If it is desirable to test 2 units simultaneously, the authors use 400 μCi Tc-99m to label an RBC aliquot of one unit and 25 μCi In-111-oxine to label the other; both labeled aliquots are injected together. The method is simple and reliable. In addition to assessing compatibility, the authors may also estimate the % viability of transfused, compatible RBC's by starting with 400 μCi of Tc-99m and multiplying % survival at 24 hours by 1.2. For 24 hr. survival measurements of IN-111-oxine-RBC's, 25 μCi is adequate and no multiplication factor is necessary. The authors have performed 13 in vivo crossmatches, 4 of which were double, in 6 patients. One documented mild transfusion reaction occurred. There were no false positive or false negative results

  14. fasting blood glucose and glycosylated haemoglobin levels

    African Journals Online (AJOL)

    Prince Acheampong

    (HbA1c) levels of diabetes mellitus patients as an index of glycaemic control. It was a prospective case- finding study using laboratory and general practice records. ... range of glycosylated haemoglobins, and the cut-off values for some clinical .... quality of glycaemic control by glycated haemoglobin in out-patient diabetic ...

  15. Anaemia prevalence and factors associated with haemoglobin ...

    African Journals Online (AJOL)

    Information on social-clinical characteristics, cancer type and associated factors as well as haemoglobin level before and after radiation were obtained. The prevalence of anaemia was determined as a proportion and linear regression was used to determine factors associated with haemoglobin change. Results: A total of ...

  16. Misleading presentation of haemoglobin electrophoresis data | Adu ...

    African Journals Online (AJOL)

    Haemoglobinopathies are common in sub-Saharan Africa. As such haemoglobin electrophoresis are required to inform clinical decision making. However, haemoglobin electrophoresis is an assay that detects protein at either alkaline or acidic pH. Such assays do not interrogate gene sequences but rather the product of a ...

  17. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  18. RBC micromotors carrying multiple cargos towards potential theranostic applications

    Science.gov (United States)

    Wu, Zhiguang; Esteban-Fernández de Ávila, Berta; Martín, Aída; Christianson, Caleb; Gao, Weiwei; Thamphiwatana, Soracha Kun; Escarpa, Alberto; He, Qiang; Zhang, Liangfang; Wang, Joseph

    2015-08-01

    Red blood cell (RBC)-based micromotors containing both therapeutic and diagnostic modalities are described as a means for potential theranostic applications. In this natural RBC-based multicargo-loaded micromotor system, quantum dots (QDs), anti-cancer drug doxorubicin (DOX), and magnetic nanoparticles (MNPs), were co-encapsulated into RBC micromotors. The fluorescent emission of both QDs and DOX provides direct visualization of their loading inside the RBC motors at two distinct wavelengths. The presence of MNPs within the RBCs allows for efficient magnetic guidance under ultrasound propulsion along with providing the potential for magnetic resonance imaging. The simultaneous encapsulation of the imaging nanoparticles and therapeutic payloads within the same RBC micromotor has a minimal effect upon its propulsion behavior. The ability of the RBC micromotors to transport imaging and therapeutic agents at high speed and spatial precision through a complex microchannel network is also demonstrated. Such ability to load and transport diagnostic imaging agents and therapeutic drugs within a single cell-based motor, in addition to a lower toxicity observed once the drug is encapsulated within the multicargo RBC motor, opens the door to the development of theranostic micromotors that may simultaneously treat and monitor diseases.Red blood cell (RBC)-based micromotors containing both therapeutic and diagnostic modalities are described as a means for potential theranostic applications. In this natural RBC-based multicargo-loaded micromotor system, quantum dots (QDs), anti-cancer drug doxorubicin (DOX), and magnetic nanoparticles (MNPs), were co-encapsulated into RBC micromotors. The fluorescent emission of both QDs and DOX provides direct visualization of their loading inside the RBC motors at two distinct wavelengths. The presence of MNPs within the RBCs allows for efficient magnetic guidance under ultrasound propulsion along with providing the potential for magnetic

  19. Relationship between glycated haemoglobin and fasting plasma ...

    African Journals Online (AJOL)

    Emmanuel Musenge

    2016-07-30

    Jul 30, 2016 ... Relationship between glycated haemoglobin and fasting plasma glucose ... major stakeholders in the management of diabetes mellitus to consider FPG as an ..... HbA1c among customers of health examination services.

  20. Predicting postoperative haemoglobin changes after burn surgery

    African Journals Online (AJOL)

    Burn surgery is associated with significant peri-operative haemoglobin. (Hb) changes. ... operative factors predictive of an Hb <7 g/dL on the first day after surgery, which were ..... clinical judgement, taking into consideration the risk associated.

  1. Studies on RBC lipid and protein phosphorylation during blood bank storage

    International Nuclear Information System (INIS)

    Dumaswala, U.J.; Bryan, D.J.; Greenwalt, T.J.

    1986-01-01

    Recent evidence has suggested that phosphoinositides play a significant role in maintaining membrane structure and function. Their importance during blood bank storage is not understood. They have performed preliminary studies of the phosphoinositide synthetic pathway enzymes of RBC during blood bank storage. At 0 and 35 days of storage leaky ghosts were prepared and incubated with [γ- 32 P]ATP for 5 minutes at 30 C. One aliquot was subjected to acidified solvent extraction and thin layer chromatography. The labeled phosphoinositide -4,5 biphosphate (PIP 2 ), phosphoinositide-4 phosphate (PIP) and phosphatidic acid (PA) spots were scraped and counted by liquid scintillation spectrometry. Another aliquot was used for SDS-PAGE and the radioactivity associated with the β-spectrin was measured. These experiments suggest a decrease in RBC phosphoinositol and PIP-Kinases and β-spectrin kinase activities during blood bank storage. Further studies are being done to evaluate significance of these observations

  2. RBC micromotors carrying multiple cargos towards potential theranostic applications.

    Science.gov (United States)

    Wu, Zhiguang; Esteban-Fernández de Ávila, Berta; Martín, Aída; Christianson, Caleb; Gao, Weiwei; Thamphiwatana, Soracha Kun; Escarpa, Alberto; He, Qiang; Zhang, Liangfang; Wang, Joseph

    2015-08-28

    Red blood cell (RBC)-based micromotors containing both therapeutic and diagnostic modalities are described as a means for potential theranostic applications. In this natural RBC-based multicargo-loaded micromotor system, quantum dots (QDs), anti-cancer drug doxorubicin (DOX), and magnetic nanoparticles (MNPs), were co-encapsulated into RBC micromotors. The fluorescent emission of both QDs and DOX provides direct visualization of their loading inside the RBC motors at two distinct wavelengths. The presence of MNPs within the RBCs allows for efficient magnetic guidance under ultrasound propulsion along with providing the potential for magnetic resonance imaging. The simultaneous encapsulation of the imaging nanoparticles and therapeutic payloads within the same RBC micromotor has a minimal effect upon its propulsion behavior. The ability of the RBC micromotors to transport imaging and therapeutic agents at high speed and spatial precision through a complex microchannel network is also demonstrated. Such ability to load and transport diagnostic imaging agents and therapeutic drugs within a single cell-based motor, in addition to a lower toxicity observed once the drug is encapsulated within the multicargo RBC motor, opens the door to the development of theranostic micromotors that may simultaneously treat and monitor diseases.

  3. Effect of RBC concentrate transfusions on serum ferritin content in children with acute leukaemia.

    Science.gov (United States)

    Bebeshko, V G; Bruslova, E M; Tsvietkova, N M; Iatsemirskii, S M; Puchkareva, T I; Gonchar, L A; Krukovska, V V; Zelinska, A V; Mishchenko, L P

    2013-01-01

    To study the serum ferritin levels in children with acute leukemia, depending on the number of transfusions of RBC concentrate and period of disease. We studied the red blood count, serum iron and ferritin levels in 54 patients with acute leukemia before chemotherapy, at the time of a standardized treatment protocol, and after transfusions of RBC concentrates. In the debute of acute leukemia just before treatment lauch the serum ferritin in 81.5% of children was 2.3-2.5 higher than normal. The need for transfusion of RBC concentrates was higher under serum ferritin level exceeding 500 ng/mL. The association was established between ferritin content and age of the children, variant of acute leukemia and period of the disease. The level of serum ferritin can be used as a marker of ferrokinetic status for timely diagnosis of iron overload in children with acute leukemias and for application of treatment-and-prophylactic actions. Bebeshko V. G., Bruslova K. M., Cvjetkova N. M., Jacemyrskyj S. M., Pushkarova T. I., Gonchar L. O., Krukovska V. V., Zelinska A. V., Mishhenko L. P., 2013.

  4. Identification of the haemoglobin scavenger receptor

    DEFF Research Database (Denmark)

    Kristiansen, M; Graversen, Jonas Heilskov; Jacobsen, C

    2001-01-01

    Intravascular haemolysis is a physiological phenomenon as well as a severe pathological complication when accelerated in various autoimmune, infectious (such as malaria) and inherited (such as sickle cell disease) disorders. Haemoglobin released into plasma is captured by the acute phase protein...

  5. Changing reference intervals for haemoglobin in Denmark

    DEFF Research Database (Denmark)

    Ryberg-Nørholt, Judith; Frederiksen, Henrik; Nybo, Mads

    2017-01-01

    INTRODUCTION: Based on international experiences and altering demography the reference intervals (RI) for haemoglobin (Hb) concentrations in blood were changed in Denmark in 2013 from 113 - 161 g/L to 117 - 153 g/L for women and from 129 - 177 g/L to 134 - 170 g/L for men. The aim of this study w...

  6. Is glycosylated haemoglobin a marker of fertility?

    DEFF Research Database (Denmark)

    Hjollund, N H; Jensen, Tina Kold; Bonde, Jens Peter

    1999-01-01

    We performed a follow-up study of time to pregnancy in a population of first-time pregnancy planners without previous reproductive experience. The objective of this paper is to report and discuss a finding of a strong relationship between glycosylated haemoglobin (HbA1C) and fertility. A total...

  7. Predicting postoperative haemoglobin changes after burn surgery ...

    African Journals Online (AJOL)

    Background. Burn surgery is associated with significant blood loss and fluid shifts that cause rapid haemoglobin (Hb) changes during and after surgery. Understanding the relationship between intraoperative and postoperative (day 1) Hb changes may assist in avoiding postoperative anaemia and unnecessary ...

  8. Haemoglobin variants among voluntary blood donors in Jos, Nigeria ...

    African Journals Online (AJOL)

    This study aimed to determine the haemoglobin variants among voluntary blood donors in Jos. METHOD: Records of the age, sex, Haemoglobin level, and the haemoglobin genotype of all voluntary blood donors who donated blood at the National Blood Transfusion Service Centre, Jos, Nigeria between January 2011 and ...

  9. Strategi Perancangan Mutu Ripe Banana Chip (RBC Berbasis Harapan Konsumen

    Directory of Open Access Journals (Sweden)

    Bambang Herry P

    2016-11-01

    Full Text Available Ripe Banana Chip (RBC, merupakan salah satu jenis kripik yang dibuat dari pisang masak. RBC dapat dilakukan dengan menggunakan teknologi penggorengan vakum (vacum frying ataupun pembekuan (freezing. RBC pisang mas cukup banyak memiliki keunggulan dari nilai gizinya. Produk ini masih belum diketahui tingkat kesesuain mutunya dengan keinginan konsumen dilihat dari aspek fisik ataupun organoleptik. Tujuan penelitian ini agar dapat mengetahui rancangan mutu yang tepat untuk produk RBC pisang mas. Penelitian ini menggunakan tiga metode, diantaranya metode skoring, Customer Satisfaction Index (CSI, dan metode diagram tulang ikan. Hasil dari penelitian, yaitu : warna RBC dengan intensitas 5,56 (kuning dan skor 3,862 (suka ; informasi kemasan dengan intensitas 4,5 (setuju dan skor 3,534 (suka ; kenyamanan kemasan dengan intensitas 8,58 (nyaman dan skor 4,155 (suka ; keamanan kemasan dengan intensitas 8,15 (sangat aman dan skor 4,086 (suka ; ketebalan dengan intensitas 8,31(sangat tebal dan skor 1,604 (sangat tidak suka ; Oil dengan intensitas 4,86 (banyak dan skor 2,483 (tidak suka ; kerenyahan dengan intensitas 7,32 (keras dan skor 2,843 (cukup suka ; Easy of breaking dengan intensitas 5,17 (mudah dipatahkan dan skor 3,158 (cukup suka ; rasa manis dengan intensitas 7,89 (manis dan skor 3,208 (cukup suka ; rasa asam dengan intensitas 4,84 (agak asam dan skor 3,309 (cukup suka. Nilai CSI yang dihasilkan, yaitu sebesar 64% (puas. Strategi untuk meningkatkan mutu RBC diantaranya: mengurangi ukuran ketebalan bahan baku sebelum diproses; lebih dipertimbangkan lagi tingkat kematangan pisang; memberi pengarahan dan motivasi kepada pekerja; melakukan pengawasan saat produksi berlangsung; lebih memperhatikan keseragaman ukuran pisang, dan menggunakan alternatif lain dalam penirisan minyak, misalnya sentrifuse agar keberadaan minyak berkurang.

  10. Racial variations in booking haemoglobin of primigravidae in Malaysia: a prospective study.

    Science.gov (United States)

    Tan, Albert Chao Chiet; Leong, Eugene Weng Kong; Chua, Ai Chen; Moy, Foong Ming

    2013-05-01

    Variations in racial haemoglobin had been previously described in multiple studies locally and abroad. This study was conducted to quantify the differences in haemoglobin of booking primigravidae amongst the three major races in Malaysia at the antenatal clinic of University Malaya Medical Centre, Kuala Lumpur. One year prospective study of booking full blood count sample of primigravidae taken in one centre was conducted. Multiple comparative analyses of the booking haemoglobin were performed using the One-way ANOVA comparative mean test in each trimester. 622 primigravidae without any known history of haematological disorders were recruited into the study. The mean haemoglobin for the Indian race was the lowest compared to the two other races in the second and the third trimesters, and it was found to be statistically significant lower (p- value 0.001) than the Malay race in the second trimester. It was also found that the Indian race had a significantly higher incidence of moderate to severe anaemia (p- value: 0.029). The prevalence of anaemia in our study population is also significantly higher in the Indian population (p- value: 0.01). The findings from this study have established that there is racial preponderance to anaemia in pregnancy. The Indian race is at a higher risk of having anaemia in pregnancy particularly in the second trimester.

  11. Placentography with technetium-99m labelled RBC - an evaluation

    International Nuclear Information System (INIS)

    Jayachandran, C.A.; Benjamin, C.S.; Balakrishnan; Narasimhan

    1983-01-01

    During 1979-80, placentography was performed in 40 cases of pregnant women with third trimester bleeding. Random labelled RBC with sup(99m)Tc of activity 2-3 mci was used, depending upon the weight of the patient. In 98% of cases, the isotope finding was confirmed. (author)

  12. Experimental evaluation of mechanical and electrical properties of RBC suspensions under flow. Role of RBC aggregating agent

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2010-01-01

    Roč. 45, 2-4 (2010), s. 253-261 ISSN 1386-0291 R&D Projects: GA AV ČR IAA200600803 Institutional research plan: CEZ:AV0Z20600510 Keywords : apparent viscosity * conductivity * unsteady flow * RBC suspensions * dextrans * PEG Subject RIV: BK - Fluid Dynamics Impact factor: 2.838, year: 2010

  13. Is glycosylated haemoglobin a marker of fertility?

    DEFF Research Database (Denmark)

    Hjollund, N H; Jensen, T K; Bonde, J P

    1999-01-01

    We performed a follow-up study of time to pregnancy in a population of first-time pregnancy planners without previous reproductive experience. The objective of this paper is to report and discuss a finding of a strong relationship between glycosylated haemoglobin (HbA1C) and fertility. A total...... concentration of inhibin A. No association was found between HbA1C and psychosocial distress. The reduced fertility among women with high HbA1C may be due to an association with subclinical polycystic ovaries as indicated by the hormonal profile....

  14. Two novel haemoglobin variants that affect haemoglobin A1c measurement by ion-exchange chromatography

    NARCIS (Netherlands)

    Bots, Michael; Stroobants, An K.; Delzenne, Barend; Soeters, Maarten R.; de Vries, Johan E.; Weykamp, Cas W.; Norg, Roelf J. C.; Veldthuis, Martijn; van Zwieten, Rob

    2015-01-01

    Haemoglobin (Hb) variants are well-known factors interfering with accurate HbA1c testing. This report describes two novel Hb variants leading to inappropriate quantification of HbA1c by ion-exchange chromatography. Glycated forms of novel Hb variants were recognised in the blood of two patients with

  15. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting.

    Science.gov (United States)

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer(®) Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.

  16. Haemoglobin A1c : Historical overview and current concepts

    NARCIS (Netherlands)

    Lenters-Westra, Erna; Schindhelm, Roger K.; Bilo, Henk J.; Slingerland, Robbert J.

    Since the discovery of the relation between increased concentrations of fast haemoglobin fractions in patients with diabetes mellitus compared to concentrations in subjects without diabetes mellitus by Samuel Rahbar and co-workers in 1969, glycated haemoglobin A1c (HbA1c) has become a "gold

  17. Should haemoglobin A be used for the diagnosis of diabetes ...

    African Journals Online (AJOL)

    2011-04-05

    Apr 5, 2011 ... Review Article: Should haemoglobin A1c be used for the diagnosis of diabetes mellitus in South Africa? 122 .... and this is the basis for the high-performance liquid .... the ionic charge of the haemoglobin molecule, and this.

  18. Field evaluation of a novel haemoglobin measuring device ...

    African Journals Online (AJOL)

    Objective. To evaluate the use of a robust, cheap method for haemoglobin estimation by non-laboratory-trained personnel in a rural setting. Design. Comparative study. Setting. Tintswalo Hospital. Acomhoek. Participants. 7 nursing sisters, 4 medical students, 2 lay persons. Outcome measures. Haemoglobin estimates ...

  19. The effects of maternal haemoglobin as an indicator of maternal ...

    African Journals Online (AJOL)

    EB

    relationship could exist between MMA of mother-infant pairs and maternal nutritional indicator (haemoglobin). Objectives: This study reviewed the effects of maternal haemoglobin (Hb) on MMA of mother-infant pairs at birth. Methods: One hundred and fifty three mother-infant pairs were enrolled in this study using the ...

  20. The effects of maternal haemoglobin as an indicator of maternal ...

    African Journals Online (AJOL)

    Background: Maternal measles antibodies (MMA) are actively transferred through the placenta from mother to foetus. A relationship could exist between MMA of mother-infant pairs and maternal nutritional indicator (haemoglobin). Objectives: This study reviewed the effects of maternal haemoglobin (Hb) on MMA of ...

  1. Haemoglobin polymorphism in wild and cultured African catfish ...

    African Journals Online (AJOL)

    Haemoglobin polymorphism, haemoglobin concentration, blood group and genotypes of wild and cultured Clarias gariepinus were investigated. Blood samples of Clarias gariepinus collected from Lake Alau (wild) and Dalori fish farm (cultured) were subjected to cellulose acetate electrophoresis to reveal the activities of ...

  2. Evaluation of a reference material for glycated haemoglobin

    NARCIS (Netherlands)

    Weykamp, CW; Penders, TJ; Muskiet, FAJ; vanderSlik, W

    The use of lyophilized blood as a reference material for glycated haemoglobin was investigated with respect to IFCC criteria for calibrators and control materials. Ninety-two laboratories, using 11 methods, detected no changes in glycated haemoglobin content when the lyophilizate was stored for one

  3. Blood count in new onset atrial fibrillation after acute myocardial infarction - A hypothesis generating study

    Directory of Open Access Journals (Sweden)

    Klaus Distelmaier

    2014-01-01

    Interpretation & conclusions: This study shows a significant independent association between serum haemoglobin, haematocrit, erythrocyte count and occurrence of AF after AMI. However, the pathophysiologic mechanism underlying these associations and its potential clinical applicability need to be further elucidated.

  4. Low vs. high haemoglobin trigger for transfusion in vascular surgery

    DEFF Research Database (Denmark)

    Møller, A; Nielsen, H B; Wetterslev, J

    2017-01-01

    of the infrarenal aorta or infrainguinal arterial bypass surgery undergo a web-based randomisation to one of two groups: perioperative RBC transfusion triggered by hb ...-up of serious adverse events in the Danish National Patient Register within 90 days is pending. DISCUSSION: This trial is expected to determine whether a RBC transfusion triggered by hb

  5. Penelitian penentuan konstanta saturasi (Ks pada rbc unit

    Directory of Open Access Journals (Sweden)

    Prayitno Prayitno

    1992-04-01

    Full Text Available Kinetic of Rotating Biological Contractor have been investigated by manu researchers. In general the model emploued either saturation kinetic (following Monod equation or first order kinetic to describe substrate removal. In this experiment, saturation kinetic model was used to find out the saturation constant of the RBC unit. The influent fed into the unit was synthetic waste water with glucose as organic carbon sources. The flow was maintained constant at 20.4 1/d and COD influent resulted the saturation constant (Ks 11.17 mg/I with 20 hours of detention time.

  6. Effect of Processing and Storage on RBC function in vivo

    Science.gov (United States)

    Doctor, Allan; Spinella, Phil

    2012-01-01

    Red Blood Cell (RBC) transfusion is indicated to improve oxygen delivery to tissue, and for no other purpose. We have come to appreciate that donor RBCs are fundamentally altered during processing and storage, in a fashion that both impairs oxygen transport efficacy and introduces additional risk by perturbing both immune and coagulation systems. The protean biophysical and physiologic changes in RBC function arising from storage are termed the ‘storage lesion’; many have been understood for some time; for example, we know that the oxygen affinity of stored blood rises during the storage period1 and that intracellular allosteric regulators, notably 2,3-bisphosphoglyceric acid (DPG) and ATP, are depleted during storage. Our appreciation of other storage lesion features has emerged with improved understanding of coagulation, immune and vascular signaling systems. Herein we review key features of the ‘storage lesion’. Additionally, we call particular attention to the newly appreciated role of RBCs in regulating linkage between regional blood flow and regional O2 consumption by regulating the bioavailability of key vasoactive mediators in plasma, as well as discuss how processing and storage disturbs this key signaling function and impairs transfusion efficacy. PMID:22818545

  7. Reference values of glycosylated haemoglobin and fructosamin in dogs

    Directory of Open Access Journals (Sweden)

    Olair Carlos Beltrame

    2014-09-01

    Full Text Available Glycated haemoglobin and fructosamin levels are not commonly used to diagnosis Diabetes mellitus in dogs due to a lack of reference values. To estabilish the reference values and determination methods of glycated haemoglobin and frutosamine, both male and females, healthy dogs, 2-8 years old (n=100 were used. The methodologies used were the ionic resin and the kinetic method by the reduction of blue nitrotetrazolium, respectively. Medium values of glycated haemoglobin of 5.3-7.01% and 277.52-387. 30 for fructosamin established by Brazilian Diabetes Society methods can be adopted for dogs, both males and females.

  8. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  9. Characterization of haemoglobin from Actinorhizal plants – An in ...

    Indian Academy of Sciences (India)

    2013-10-01

    Oct 1, 2013 ... Actinorhizal plant; haemoglobin (Hb); homology modelling; vesicle ..... specifies the overall quality of the models and determines the extent to which .... service for the recognition of errors in three-dimensional struc- tures of ...

  10. Dietary pattern, haemoglobin and haematocrit status of pregnant ...

    African Journals Online (AJOL)

    Dietary pattern, haemoglobin and haematocrit status of pregnant women in Ogbaru ... Nigerian Journal of Nutritional Sciences ... 220 out of 733 pregnant women attending antenatal clinics in the health centres within the three communities.

  11. Multiple-capillary measurement of RBC speed, flux, and density with optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Wu, Weicheng; Lesage, Frederic; Boas, David A

    2013-11-01

    As capillaries exhibit heterogeneous and fluctuating dynamics even during baseline, a technique measuring red blood cell (RBC) speed and flux over many capillaries at the same time is needed. Here, we report that optical coherence tomography can capture individual RBC passage simultaneously over many capillaries located at different depths. Further, we demonstrate the ability to quantify RBC speed, flux, and linear density. This technique will provide a means to monitor microvascular flow dynamics over many capillaries at different depths at the same time.

  12. Investigation of haemoglobin polymorphism in Ogaden cattle

    Directory of Open Access Journals (Sweden)

    Sanjoy Kumar Pal

    2014-04-01

    Full Text Available Background and Aim: The Ogaden cattle is one among the tropical cattle breeds (Bos indicus widely distributed in eastern and south eastern part of Ethiopia. The breed has been evolved in arid and semi arid agro-ecological setup, but later on distributed and adapted to the wide agro-ecological zones. Because of its multi-purpose role, the Ogaden cattle have been used for milk, beef, and income generation. Information on the inherent genetic diversity is important in the design of breeding improvement programmes, making rational decisions on sustainable utilization and conservation of Animal Genetic Resources. Limited information is available about genetic variation of Ogaden breed at molecular level. The present investigation was aimed to study the biochemical polymorphism at the Hemoglobin (Hb locus. Materials and Methods: Blood samples collected from 105 Ogaden cattle maintained at Haramaya beef farm by jugular vein puncture were subjected to agarose gel electrophoresis [pH range 8.4-8.5] to study the polymorphic activities of haemoglobin. Results: Three types of phenotypes were detected i.e. a slow moving (AA band, fast moving (BB band and a combination of slow + fast moving bands (AB. The frequency of the fast moving band was less [13 (12.3%] than the slow moving band [57 (54.2%]. Both slow & fast moving phenotype was observed in 35 (33.3% animals. The gene frequency of HBA allele was 0.709 and that of HBB allele 0.291. Conclusion: The distribution of phenotypes was in agreement with codominant single gene inheritance. The Chi-square (χ2 test revealed that the population is under Hardy-Weinberg equilibrium.

  13. The effects of an overnight holding of whole blood at room temperature on haemoglobin modification and in vitro markers of red blood cell aging.

    Science.gov (United States)

    Eckstein, M; Zimmermann, R; Roth, T; Hauck-Dlimi, B; Strasser, E F; Xiang, W

    2015-05-01

    Some effects of the red blood cell (RBC) storage lesion are well documented whereas others are not. Whether a period of room temperature hold (RTH) during RBC production enhances the RBC storage lesion has remained controversial. In this study, we compared whole blood (WB)-derived RBCs produced after 24-h RTH with rapidly cooled (RC) RBCs and tested them for classical metabolic markers and signs of oxidative damage. SAGM-RBCs were prepared from mixed and split pairs (n = 12) of WB units. RBCs prepared after a 24-h period of RTH on day+1 after collection (RTH-RBCs) were compared with RC-RBCs. All RBCs were stored at 4°C for 42 days with assay of in vitro variables on days+1, +15, +22, +29 and +42. The study examined standard quality parameters, glutathione, catalase and superoxide dismutase (SOD) activities, and indicative markers of oxidative cell damage including post-translational haemoglobin modification, malondialdehyde (MDA), and phosphatidylserine expression. RTH-RBCs exhibited decreased levels of potassium (1·98 ± 0·26 vs. 5·23 ± 0·65 mmol/l) and of 2,3-diphosphoglycerate (2,3-DPG) on day+1 compared with RC-RBCs. Haemolysis rate on day+42 was higher in RTH-RBCs than in RC-RBCs (0·52 ± 0·13 vs. 0·37 ± 0·12%). The phosphatidylserine expression amounted to 0·25 ± 0·20% in RTH-RBCs and 0·07 ± 0·12% in RC-RBCs. Haemoglobin modification was not different between both RBC groups. RTH-RBCs showed slightly higher MDA concentration on days +29 and +42. RC-RBCs and RTH-RBCs show only small differences of classical in vitro parameters and no relevant differences in antioxidative metabolism and oxidative haemoglobin modification. These findings do not explain the loss observed in in vivo survival studies with RBCs. © 2015 International Society of Blood Transfusion.

  14. Changes in haematology, plasma biochemistry and erythrocyte ...

    African Journals Online (AJOL)

    olayemitoyin

    anaemia characterized by reduced values for packed cell volume (PCV), red blood cell count (RBC), haemoglobin (Hb) ... total white blood cell count, heterophil, lymphocyte and monocyte counts were ..... Theory, Analysis, and Correlation.

  15. Exercise and sports in haemoglobin disorders

    Directory of Open Access Journals (Sweden)

    D. Yazman

    2011-12-01

    Full Text Available Anaemia causes lower oxygen transport to tissues, interfering with normal physical development and may interfere with exercise and sports in thalassemia and Sickle-Cell-Disease (SCD l. Moreover, in SCD, the abnormal haemoglobin alters the erythrocyte shape and leads to pulmonary parenchymal damage, impaired vascular function and micro vascular complications. However, we now accept that, with regular blood transfusions and efficient oral or parenteral chelation modalities, many patients lead a normal development and life with little or no change from the lifestyle of their unaffected friends, although there are cognitive and emotional factors leading behaviour for participation in the social life and exercise, as studied by many scientists in Italy, United Kingdom, Greece and India. 贫血导致组织供氧不足,妨碍身体的正常发育,并可能干扰地中海贫血和镰状细胞病(SCD)患者的体育运动。更严重的是,在镰状细胞病患者体内,异常血红蛋白能改变红细胞形态,造成肺薄壁组织损害、血管功能损伤,并引起微血管并发症。 然而,意大利、英国、希腊和印度的多位科学家的研究表明:尽管认知因子和情感因子是参加社会生活和运动的主导行为,但只要患者定期输血和采用高效的口服或非口服螯合疗法,很多人都可以正常发育和生活,与未受感染的人群并无大的区别。

  16. Vessel calibre and haemoglobin effects on pulse oximetry

    International Nuclear Information System (INIS)

    McEwen, M P; Reynolds, K J; Bull, G P

    2009-01-01

    Despite its success as a clinical monitoring tool, pulse oximetry may be improved with respect to the need for empirical calibration and the reports of biases in readings associated with peripheral vasoconstriction and haemoglobin concentration. To effect this improvement, this work aims to improve the understanding of the photoplethysmography signal—as used by pulse oximeters—and investigates the effect of vessel calibre and haemoglobin concentration on pulse oximetry. The digital temperature and the transmission of a wide spectrum of light through the fingers of 57 people with known haemoglobin concentrations were measured and simulations of the transmission of that spectrum of light through finger models were performed. Ratios of pulsatile attenuations of light as used in pulse oximetry were dependent upon peripheral temperature and on blood haemoglobin concentration. In addition, both the simulation and in vivo results showed that the pulsatile attenuation of light through fingers was approximately proportional to the absorption coefficients of blood, only when the absorption coefficients were small. These findings were explained in terms of discrete blood vessels acting as barriers to light transmission through tissue. Due to the influence of discrete blood vessels on light transmission, pulse oximeter outputs tend to be dependent upon haemoglobin concentration and on the calibre of pulsing blood vessels—which are affected by vasoconstriction/vasodilation. The effects of discrete blood vessels may account for part of the difference between the Beer–Lambert pulse oximetry model and empirical calibration

  17. Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Kim, J G; Liu, H

    2007-01-01

    Near-infrared spectroscopy or imaging has been extensively applied to various biomedical applications since it can detect the concentrations of oxyhaemoglobin (HbO 2 ), deoxyhaemoglobin (Hb) and total haemoglobin (Hb total ) from deep tissues. To quantify concentrations of these haemoglobin derivatives, the extinction coefficient values of HbO 2 and Hb have to be employed. However, it was not well recognized among researchers that small differences in extinction coefficients could cause significant errors in quantifying the concentrations of haemoglobin derivatives. In this study, we derived equations to estimate errors of haemoglobin derivatives caused by the variation of haemoglobin extinction coefficients. To prove our error analysis, we performed experiments using liquid-tissue phantoms containing 1% Intralipid in a phosphate-buffered saline solution. The gas intervention of pure oxygen was given in the solution to examine the oxygenation changes in the phantom, and 3 mL of human blood was added twice to show the changes in [Hb total ]. The error calculation has shown that even a small variation (0.01 cm -1 mM -1 ) in extinction coefficients can produce appreciable relative errors in quantification of Δ[HbO 2 ], Δ[Hb] and Δ[Hb total ]. We have also observed that the error of Δ[Hb total ] is not always larger than those of Δ[HbO 2 ] and Δ[Hb]. This study concludes that we need to be aware of any variation in haemoglobin extinction coefficients, which could result from changes in temperature, and to utilize corresponding animal's haemoglobin extinction coefficients for the animal experiments, in order to obtain more accurate values of Δ[HbO 2 ], Δ[Hb] and Δ[Hb total ] from in vivo tissue measurements

  18. Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy

    Science.gov (United States)

    Kim, J. G.; Liu, H.

    2007-10-01

    Near-infrared spectroscopy or imaging has been extensively applied to various biomedical applications since it can detect the concentrations of oxyhaemoglobin (HbO2), deoxyhaemoglobin (Hb) and total haemoglobin (Hbtotal) from deep tissues. To quantify concentrations of these haemoglobin derivatives, the extinction coefficient values of HbO2 and Hb have to be employed. However, it was not well recognized among researchers that small differences in extinction coefficients could cause significant errors in quantifying the concentrations of haemoglobin derivatives. In this study, we derived equations to estimate errors of haemoglobin derivatives caused by the variation of haemoglobin extinction coefficients. To prove our error analysis, we performed experiments using liquid-tissue phantoms containing 1% Intralipid in a phosphate-buffered saline solution. The gas intervention of pure oxygen was given in the solution to examine the oxygenation changes in the phantom, and 3 mL of human blood was added twice to show the changes in [Hbtotal]. The error calculation has shown that even a small variation (0.01 cm-1 mM-1) in extinction coefficients can produce appreciable relative errors in quantification of Δ[HbO2], Δ[Hb] and Δ[Hbtotal]. We have also observed that the error of Δ[Hbtotal] is not always larger than those of Δ[HbO2] and Δ[Hb]. This study concludes that we need to be aware of any variation in haemoglobin extinction coefficients, which could result from changes in temperature, and to utilize corresponding animal's haemoglobin extinction coefficients for the animal experiments, in order to obtain more accurate values of Δ[HbO2], Δ[Hb] and Δ[Hbtotal] from in vivo tissue measurements.

  19. Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J G; Liu, H [Joint Graduate Program in Biomedical Engineering, University of Texas at Arlington/University of Texas Southwestern Medical Center at Dallas, Arlington, TX 76019 (United States)

    2007-10-21

    Near-infrared spectroscopy or imaging has been extensively applied to various biomedical applications since it can detect the concentrations of oxyhaemoglobin (HbO{sub 2}), deoxyhaemoglobin (Hb) and total haemoglobin (Hb{sub total}) from deep tissues. To quantify concentrations of these haemoglobin derivatives, the extinction coefficient values of HbO{sub 2} and Hb have to be employed. However, it was not well recognized among researchers that small differences in extinction coefficients could cause significant errors in quantifying the concentrations of haemoglobin derivatives. In this study, we derived equations to estimate errors of haemoglobin derivatives caused by the variation of haemoglobin extinction coefficients. To prove our error analysis, we performed experiments using liquid-tissue phantoms containing 1% Intralipid in a phosphate-buffered saline solution. The gas intervention of pure oxygen was given in the solution to examine the oxygenation changes in the phantom, and 3 mL of human blood was added twice to show the changes in [Hb{sub total}]. The error calculation has shown that even a small variation (0.01 cm{sup -1} mM{sup -1}) in extinction coefficients can produce appreciable relative errors in quantification of {delta}[HbO{sub 2}], {delta}[Hb] and {delta}[Hb{sub total}]. We have also observed that the error of {delta}[Hb{sub total}] is not always larger than those of {delta}[HbO{sub 2}] and {delta}[Hb]. This study concludes that we need to be aware of any variation in haemoglobin extinction coefficients, which could result from changes in temperature, and to utilize corresponding animal's haemoglobin extinction coefficients for the animal experiments, in order to obtain more accurate values of {delta}[HbO{sub 2}], {delta}[Hb] and {delta}[Hb{sub total}] from in vivo tissue measurements.

  20. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  1. Higher vs. lower haemoglobin threshold for transfusion in septic shock

    DEFF Research Database (Denmark)

    Rygård, S L; Holst, L B; Wetterslev, J

    2017-01-01

    . a lower haemoglobin threshold. METHODS: In post-hoc analyses of the full trial population of 998 patients from the Transfusion Requirements in Septic Shock (TRISS) trial, we investigated the intervention effect on 90-day mortality in patients with severe comorbidity (chronic lung disease, haematological......BACKGROUND: Using a restrictive transfusion strategy appears to be safe in sepsis, but there may be subgroups of patients who benefit from transfusion at a higher haemoglobin level. We explored if subgroups of patients with septic shock and anaemia had better outcome when transfused at a higher vs.......51), in those who had undergone surgery (P = 0.99) or in patients with septic shock by the new definition (P = 0.20). CONCLUSION: In exploratory analyses of a randomized trial in patients with septic shock and anaemia, we observed no survival benefit in any subgroups of transfusion at a haemoglobin threshold...

  2. Discriminating plants using the DNA barcode rbcLb: an appraisal based on a large data set.

    Science.gov (United States)

    Dong, Wenpan; Cheng, Tao; Li, Changhao; Xu, Chao; Long, Ping; Chen, Chumming; Zhou, Shiliang

    2014-03-01

    The ideal DNA barcode for plants remains to be discovered, and the candidate barcode rbcL has been met with considerable skepticism since its proposal. In fact, the variability within this gene has never been fully explored across all plant groups from algae to flowering plants, and its performance as a barcode has not been adequately tested. By analysing all of the rbcL sequences currently available in GenBank, we attempted to determine how well a region of rbcL performs as a barcode in species discrimination. We found that the rbcLb region was more variable than the frequently used rbcLa region. Both universal and plant group-specific primers were designed to amplify rbcLb, and the performance of rbcLa and rbcLb was tested in several ways. Using blast, both regions successfully identified all families and nearly all genera; however, the successful species identification rates varied significantly among plant groups, ranging from 24.58% to 85.50% for rbcLa and from 36.67% to 90.89% for rbcLb. Successful species discrimination ranged from 5.19% to 96.33% for rbcLa and from 22.09% to 98.43% for rbcLb in species-rich families, and from 0 to 88.73% for rbcLa and from 2.04% to 100% for rbcLb in species-rich genera. Both regions performed better for lower plants than for higher plants, although rbcLb performed significantly better than rbcLa overall, particularly for angiosperms. Considering the applicability across plants, easy and unambiguous alignment, high primer universality, high sequence quality and high species discrimination power for lower plants, we suggest rbcLb as a universal plant barcode. © 2013 John Wiley & Sons Ltd.

  3. Molecular cloning of RBCS genes in Selaginella and the evolution of the rbcS gene family

    Directory of Open Access Journals (Sweden)

    Wang Bo

    2015-01-01

    Full Text Available Rubisco small subunits (RBCS are encoded by a nuclear rbcS multigene family in higher plants and green algae. However, owing to the lack of rbcS sequences in lycophytes, the characteristics of rbcS genes in lycophytes is unclear. Recently, the complete genome sequence of the lycophyte Selaginella moellendorffii provided the first insight into the rbcS gene family in lycophytes. To understand further the characteristics of rbcS genes in other Selaginella, the full length of rbcS genes (rbcS1 and rbcS2 from two other Selaginella species were isolated. Both rbcS1 and rbcS2 genes shared more than 97% identity among three Selaginella species. RBCS proteins from Selaginella contained the Pfam RBCS domain F00101, which was a major domain of other plant RBCS proteins. To explore the evolution of the rbcS gene family across Selaginella and other plants, we identified and performed comparative analysis of the rbcS gene family among 16 model plants based on a genome-wide analysis. The results showed that (i two rbcS genes were obtained in Selaginella, which is the second fewest number of rbcS genes among the 16 representative plants; (ii an expansion of rbcS genes occurred in the moss Physcomitrella patens; (iii only RBCS proteins from angiosperms contained the Pfam PF12338 domains, and (iv a pattern of concerted evolution existed in the rbcS gene family. Our study provides new insights into the evolution of the rbcS gene family in Selaginella and other plants.

  4. The study of x-ray photo-electron spectroscopy of 99mTc-RBC

    International Nuclear Information System (INIS)

    Song Chunyi

    1994-01-01

    99m Tc-RBC are widely used as visualization agents for a blood pool. In this research 99m Tc-RBC was prepared by in vivo labeling. The chemical state and changes of 99m Tc atoms in 99m Tc-RBC was determined by x-ray photo-electron spectroscopy (XPS). The stability of 99m Tc-RBC is best shown by the determination of XPS at one hour or at two hours after labeling. There are two ways of coordination of bonding of RBC and 99m Tc: One is the coordination of 99m Tc with the oxygen atom which carries a negative charge of the carboxyl radical on the polypeptide bond, the other is the coordination of 99m Tc with a sulfur atom which caries the negative charge of cysteine. From the E b value of 99m Tc-RBC 99m Tc 3d5/2, it can be inferred that 99m Tc of 99m Tc-RBC is less than a trivalent. At the same time, the results of the determination by XPS with the compounds containing 99 TcO 4 - , 99 Tc(V), 99 Tc(IV) and 99 Tc(III) show that the chemical shift is lowered as the reduction state is lowered. Experimental results coincide with theoretical inferences

  5. An On-Chip RBC Deformability Checker Significantly Improves Velocity-Deformation Correlation

    Directory of Open Access Journals (Sweden)

    Chia-Hung Dylan Tsai

    2016-10-01

    Full Text Available An on-chip deformability checker is proposed to improve the velocity–deformation correlation for red blood cell (RBC evaluation. RBC deformability has been found related to human diseases, and can be evaluated based on RBC velocity through a microfluidic constriction as in conventional approaches. The correlation between transit velocity and amount of deformation provides statistical information of RBC deformability. However, such correlations are usually only moderate, or even weak, in practical evaluations due to limited range of RBC deformation. To solve this issue, we implemented three constrictions of different width in the proposed checker, so that three different deformation regions can be applied to RBCs. By considering cell responses from the three regions as a whole, we practically extend the range of cell deformation in the evaluation, and could resolve the issue about the limited range of RBC deformation. RBCs from five volunteer subjects were tested using the proposed checker. The results show that the correlation between cell deformation and transit velocity is significantly improved by the proposed deformability checker. The absolute values of the correlation coefficients are increased from an average of 0.54 to 0.92. The effects of cell size, shape and orientation to the evaluation are discussed according to the experimental results. The proposed checker is expected to be useful for RBC evaluation in medical practices.

  6. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  7. Impact of corpulence parameters and haemoglobin A1c on ...

    African Journals Online (AJOL)

    We assessed the utility of body mass index (BMI), waist circumference (WC), and glycosylated haemoglobin (HbA1c) levels in metabolic control for type 2 diabetic patients. ... The apoB/apoA-I ratio was more correlated with postprandial TC/HDL and LDL-c/HDL-c ratios in men and with postprandial TG/HDL-c in women.

  8. Abnormal haemoglobin variants, ABO and Rh blood groups among ...

    African Journals Online (AJOL)

    Background: Abnormal haemoglobin variants ( HbSS,AS,AC,SC,etc) have been known to be common among blacks. Patients with sickle cell disease are often faced with the risk of alloimmunization from allogeneic blood transfusion. Objectives: The study was designed to sample students population of African descents for ...

  9. Relationship Between Glycated Haemoglobin and Body Mass Index ...

    African Journals Online (AJOL)

    Blood pressure, Height, Weight were all measured and body mass index (BMI) calculated as weight (in kilograms) divided by height (in meters squared). Glycated haemoglobin was estimated using the ion exchange chromatography method. Result: A total of 100 healthy subjects, 50 males and 50 females, ages ranging ...

  10. Crystallization and preliminary crystallographic analysis of human glycosylated haemoglobin

    International Nuclear Information System (INIS)

    Syakhovich, Vitaly E.; Saraswathi, N. T.; Ruff, Marc; Bokut, Sergey B.; Moras, Dino

    2006-01-01

    Non enzymatic modification of haemoglobin by glucose plays an important role in diabetes pathogenesis. Here the purification, characterization and crystallization of human glycosylated haemoglobin are reported. Human glycosylated haemoglobin A 1C is a stable minor variant formed in vivo by post-translational modification of the main form of haemoglobin by glucose. Crystals of oxyHbA 1C were obtained using the hanging-drop vapour-diffusion method and PEG as precipitant. The diffraction pattern of the crystal extends to a resolution of 2.3 Å at 120 K. The crystals belong to space group C2, with unit-cell parameters a = 237.98, b = 59.27, c = 137.02 Å, α = 90.00, β = 125.40, γ = 90.00°. The presence of two and a half molecules per asymmetric unit gives a crystal volume per protein weight (V M ) of 9.70 Å 3 Da −1 and a solvent content of 49%

  11. Association of foetal haemoglobin with pancreatic enzymes in sickle ...

    African Journals Online (AJOL)

    Background/Aim: There are conflicting reports on the potential protective effects of foetal haemoglobin (HbF) in the elimination of symptoms of Sickle cell disease in the patients and reports which correlate the levels of HbF with pancreatic enzymes in SCD are scarce in the literature.This study correlates the levels of HbF on ...

  12. Non-invasive technology to determine the haemoglobin level of ...

    African Journals Online (AJOL)

    Background: Predonation haemoglobin (Hb) check has been done traditionally by the copper sulphate (CuSO4), or the haemocue haemoglobinometer methods. Both of these require a fingerprick of the donor to obtain capillary blood samples. It is thought that a non-invasive, but accurate method of Hb check will reduce ...

  13. Distribution of abo, rhesus blood groups and haemoglobin ...

    African Journals Online (AJOL)

    Summary: The distribution of ABO, Rhesus blood groups and haemoglobin electrophoresis among 200 undergraduate students of Niger Delta University, Bayelsa State, Nigeria randomly selected were studied. Blood samples were collected by venepuncture from the antecubital vein. The blood sample were transferred into ...

  14. Validation of the haemoglobin colour scale for screening blood ...

    African Journals Online (AJOL)

    blood donors for anaemia, using the WHO Haemoglobin Colour. Scale (HCS) for ... simple alternative for assessing anaemia.3,4 It does not aim to compete with a .... staff to see if similar levels of sensitivity and specificity are obtained. A more ...

  15. Crystallization and preliminary crystallographic analysis of human glycosylated haemoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Syakhovich, Vitaly E. [Department of Biochemistry and Biophysics, International Sakharov Environmental University, Dolgobrodskaya St 23, 220009 Minsk (Belarus); Saraswathi, N. T.; Ruff, Marc, E-mail: ruff@igbmc.u-strasbg.fr [Département de Biologie et Génomique Structurales, Institut de Génétique et de Biologie Moléculaire et Cellulaire, 1 Rue Laurent Fries, BP 10142, 67404 Illkirch (France); Bokut, Sergey B. [Department of Biochemistry and Biophysics, International Sakharov Environmental University, Dolgobrodskaya St 23, 220009 Minsk (Belarus); Moras, Dino [Département de Biologie et Génomique Structurales, Institut de Génétique et de Biologie Moléculaire et Cellulaire, 1 Rue Laurent Fries, BP 10142, 67404 Illkirch (France); Department of Biochemistry and Biophysics, International Sakharov Environmental University, Dolgobrodskaya St 23, 220009 Minsk (Belarus)

    2006-02-01

    Non enzymatic modification of haemoglobin by glucose plays an important role in diabetes pathogenesis. Here the purification, characterization and crystallization of human glycosylated haemoglobin are reported. Human glycosylated haemoglobin A{sub 1C} is a stable minor variant formed in vivo by post-translational modification of the main form of haemoglobin by glucose. Crystals of oxyHbA{sub 1C} were obtained using the hanging-drop vapour-diffusion method and PEG as precipitant. The diffraction pattern of the crystal extends to a resolution of 2.3 Å at 120 K. The crystals belong to space group C2, with unit-cell parameters a = 237.98, b = 59.27, c = 137.02 Å, α = 90.00, β = 125.40, γ = 90.00°. The presence of two and a half molecules per asymmetric unit gives a crystal volume per protein weight (V{sub M}) of 9.70 Å{sup 3} Da{sup −1} and a solvent content of 49%.

  16. Prevalence of haemoglobin variants among the Ika ethnic nationality ...

    African Journals Online (AJOL)

    McRoy

    2014-07-26

    Jul 26, 2014 ... mandatory genetic counseling and screening of all intending couples in order to avert the sickling gene pool in our population. REFERENCES. 1. Esan A.J, Omisakin C.T and Okkhuakhua. O. Frequency Distribution of Haemoglobin. Variants, ABO and Rhesus Blood Groups among Children in Ido/Osi Local.

  17. Haemoglobin genotype of children with severe malaria seen at the ...

    African Journals Online (AJOL)

    Abstract: Introduction: Types of haemoglobin (Hb) genotype have been found to be crucial to the rate of red blood cell parasite invasion, multiplication, and destruction as well as outcome of malaria disease. In a bid to provide more information on the relationship between Hb genotype and level of protection conferred by ...

  18. Point-of-care estimation of haemoglobin concentration in neonates ...

    African Journals Online (AJOL)

    Objective. The HemoCue is a point-of-care analytical system for haemoglobin concentration (Hb) measurement. Point-of-care testing has been validated in hospitals and outpatient departments to assist with urgent patient management by providing rapid laboratory test results. Method. In this prospective study we compared ...

  19. RBC-choline: changes by lithium and relation to prophylactic response

    International Nuclear Information System (INIS)

    Haag, M.; Haag, H.; Eisenried, F.; Greil, W.

    1984-01-01

    Red blod cell (RBC)- and plasma-choline levels were measured in patients on lithium (n=96), antidepressants (n=32) and neuroleptics (n=51) and in 25 healthy drug-free controls. Lithium patients exhibited highly increased RBC- and slightly increased plasma-choline levels compared with controls (P<0.001 and P<0.05, respectively); the choline ratio (RBC-/plasma-choline) was elevated almost to the same extent as RBC-choline (P<0.001). With antidepressants RBC-choline and choline ratios were slightly reduced (P<0.05), whereas neuroleptics showed no effect on choline levels. 79% of lithium patients were responders (reduction in hospitalizations with lithium) 21% were non-responders (no reduction or increase in hospitalizations). Choline ratio exhibited a significant relation to prophylactic lithium response, but lithium ratio did not. The percentage of non-responders was significantly higher in patients with a choline ratio exceeding 100 than in patients with a choline ratio below this cut-off (P<0.01). Thus, the increase of RBC-choline and choline ratios appears to be an effect specific for lithium and might be related to the outcome of lithium prophylaxis. (author)

  20. Isolation, expression and characterization of rbcL gene from Ulva prolifera J. Agardh (Ulvophyceae, Chlorophyta)

    Science.gov (United States)

    Shao, Zhanru; Li, Wei; Guo, Hui; Duan, Delin

    2015-12-01

    Ulva prolifera is a typical green alga in subtidal areas and can grow tremendously fast. A highly efficient Rubisco enzyme which is encoded by UpRbcL gene may contribute to the rapid growth. In this study, the full-length UpRbcL open reading frame (ORF) was identified, which encoded a protein of 474 amino acids. Phylogenetic analysis of UpRbcL sequences revealed that Chlorophyta had a closer genetic relationship with higher plants than with Rhodophyta and Phaeophyta. The two distinct residues (aa11 and aa91) were presumed to be unique for Rubisco catalytic activity. The predicted three-dimensional structure showed that one α/β-barrel existed in the C-terminal region, and the sites for Mg2+ coordination and CO2 fixation were also located in this region. Gene expression profile indicated that UpRbcL was expressed at a higher level under light exposure than in darkness. When the culture temperature reached 35°C, the expression level of UpRbcL was 2.5-fold lower than at 15°C, and the carboxylase activity exhibited 13.8-fold decrease. UpRbcL was heterologously expressed in E. coli and was purified by Ni2+ affinity chromatography. The physiological and biochemical characterization of recombinant Rubisco will be explored in the future.

  1. Experimental evaluation of mechanical and electrical properties of RBC suspensions in Dextran and PEG under flow II. Role of RBC deformability and morphology

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.; Gluhcheva, Y.

    2011-01-01

    Roč. 49, 1-4 (2011), s. 441-450 ISSN 1386-0291 Institutional research plan: CEZ:AV0Z20600510 Keywords : RBC suspensions * conductivity * Dextran 70 * Polyethylene glycol 35 000 (PEG) Subject RIV: BK - Fluid Dynamics Impact factor: 3.398, year: 2011

  2. Experimental evaluation of mechanical and electrical properties of RBC suspensions in Dextran and PEG under flow II. Role of RBC deformability and morphology

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.; Gluhcheva, Y.

    2011-01-01

    Roč. 49, 1-4 (2011), s. 441-450 ISSN 1386-0291 Institutional research plan: CEZ:AV0Z20600510 Keywords : RBC suspensions * conductivity * Dextran 70 * Polyethylene glycol 35 000 ( PEG ) Subject RIV: BK - Fluid Dynamics Impact factor: 3.398, year: 2011

  3. E.s.r. radiation studies of erythrocyte membrane-haemoglobin interaction

    International Nuclear Information System (INIS)

    Koter, M.; Kowalska, M.A.; Leyko, W.; Waterman, M.

    1977-01-01

    The dependence of the yield of free radicals in gamma-irradiated, freeze-dried erythrocyte membranes on their haemoglobin content was studied. A non-monotonous relationship was found, different from that observed in mixtures of freeze-dried membranes and haemoglobin, which suggests the existence of radiation-energy transfer between the membranes and bound haemoglobin. (author)

  4. Knowledge insufficient: the management of haemoglobin SC disease.

    Science.gov (United States)

    Pecker, Lydia H; Schaefer, Beverly A; Luchtman-Jones, Lori

    2017-02-01

    Although haemoglobin SC (HbSC) accounts for 30% of sickle cell disease (SCD) in the United States and United Kingdom, evidence-based guidelines for genotype specific management are lacking. The unique pathology of HbSC disease is complex, characterized by erythrocyte dehydration, intracellular sickling and increased blood viscosity. The evaluation and treatment of patients with HbSC is largely inferred from studies of SCD consisting mostly of haemoglobin SS (HbSS) patients. These studies are underpowered to allow definitive conclusions about HbSC. We review the pathophysiology of HbSC disease, including known and potential differences between HbSS and HbSC, and highlight knowledge gaps in HbSC disease management. Clinical and translational research is needed to develop targeted treatments and to validate management recommendations for efficacy, safety and impact on quality of life for people with HbSC. © 2016 John Wiley & Sons Ltd.

  5. Haemoglobins with multiple reactive sulfhydryl groups: reactions of ...

    African Journals Online (AJOL)

    The pH dependence profile of kapp for the slow phase resembles the titration curve of a monoprotic acid. Quantitative analysis indicates that the sulfhydryl group to which this phase may be attributed is linked to a single ionizable group with a pKa of 6.1 0.2. Examination of the structure of guinea pig haemoglobin near the ...

  6. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  7. SERUM MAGNESIUM, LIPID PROFILE AND GLYCATED HAEMOGLOBIN IN DIABETIC RETINOPATHY

    Directory of Open Access Journals (Sweden)

    Sunanda Vusikala

    2016-07-01

    Full Text Available BACKGROUND Diabetic retinopathy is one of the important microvascular complications of diabetes mellitus of long duration. Alterations in trace metals like magnesium and lipid profile was observed in diabetic retinopathy with hyperglycaemic status. AIM The study was taken up to assess the role of magnesium, lipid profile and glycated haemoglobin in diabetic retinopathy. MATERIALS AND METHODS A total of 80 subjects between 40-65 years were included in the study. Group 1 includes 20 age and sex matched healthy controls. Group 2 includes 30 cases of Diabetes mellitus without retinopathy. Group 3 includes 30 cases of Diabetes mellitus with retinopathy. RESULTS Magnesium was found to be significantly low in the diabetic group with retinopathy. Serum cholesterol and triglycerides were significantly elevated in the diabetic group with retinopathy. Fasting and Postprandial plasma glucose and glycated haemoglobin (HbA1c levels confirmed the glycaemic status of each of the groups. CONCLUSIONS Hypomagnesemia, hypercholesterolaemia, hypertriglyceridemia was observed in diabetic retinopathy along with increased levels of glycated haemoglobin in our study.

  8. d-Ribose as a Contributor to Glycated Haemoglobin

    Directory of Open Access Journals (Sweden)

    Xixi Chen

    2017-11-01

    Full Text Available Glycated haemoglobin (HbA1c is the most important marker of hyperglycaemia in diabetes mellitus. We show that d-ribose reacts with haemoglobin, thus yielding HbA1c. Using mass spectrometry, we detected glycation of haemoglobin with d-ribose produces 10 carboxylmethyllysines (CMLs. The first-order rate constant of fructosamine formation for d-ribose was approximately 60 times higher than that for d-glucose at the initial stage. Zucker Diabetic Fatty (ZDF rat, a common model for type 2 diabetes mellitus (T2DM, had high levels of d-ribose and HbA1c, accompanied by a decrease of transketolase (TK in the liver. The administration of benfotiamine, an activator of TK, significantly decreased d-ribose followed by a decline in HbA1c. In clinical investigation, T2DM patients with high HbA1c had a high level of urine d-ribose, though the level of their urine d-glucose was low. That is, d-ribose contributes to HbA1c, which prompts future studies to further explore whether d-ribose plays a role in the pathophysiological mechanism of T2DM.

  9. Red blood cell (RBC) suspensions in confined microflows: Pressure-flow relationship.

    Science.gov (United States)

    Stauber, Hagit; Waisman, Dan; Korin, Netanel; Sznitman, Josué

    2017-10-01

    Microfluidic-based assays have become increasingly popular to explore microcirculation in vitro. In these experiments, blood is resuspended to a desired haematocrit level in a buffer solution, where frequent choices for preparing RBC suspensions comprise notably Dextran and physiological buffer. Yet, the rational for selecting one buffer versus another is often ill-defined and lacks detailed quantification, including ensuing changes in RBC flow characteristics. Here, we revisit RBC suspensions in microflows and attempt to quantify systematically some of the differences emanating between buffers. We measure bulk flow rate (Q) of RBC suspensions, using PBS- and Dextran-40, as a function of the applied pressure drop (ΔP) for two hematocrits (∼0% and 23%). Two distinct microfluidic designs of varying dimensions are employed: a straight channel larger than and a network array similar to the size of individual RBCs. Using the resulting pressure-flow curves, we extract the equivalent hydrodynamic resistances and estimate the relative viscosities. These efforts are a first step in rigorously quantifying the influence of the 'background' buffer on RBC flows within microfluidic devices and thereby underline the importance of purposefully selecting buffer suspensions for microfluidic in vitro assays. Copyright © 2017. Published by Elsevier Ltd.

  10. Preoperative diagnosis of orbital cavernous hemangioma: a 99mTc-RBC SPECT study.

    Science.gov (United States)

    Burroni, Luca; Borsari, Giulia; Pichierri, Patrizia; Polito, Ennio; Toscano, Olga; Grassetto, Gaia; Al-Nahhas, Adil; Rubello, Domenico; Vattimo, Angelo Giuseppe

    2012-11-01

    This study aimed to describe 99mTc-labeled RBC scintigraphy as a diagnostic method for orbital cavernous hemangiomas and to evaluate this diagnostic tool according to surgical outcomes. Fifty-five patients with clinical and radiological (US, CT, and/or MRI) suspicion of unilateral cavernous hemangioma of the orbit underwent 99mTc-RBC SPECT study.Qualitative and semiquantitative evaluations were performed, and results were statistically analyzed. SPECT images showed focal uptake in the orbital mass in 36 of 55 patients. Nineteen patients had a negative scintigraphic pattern, with concordance of early and late absence of uptake of 99mTc-RBC.Our procedure showed 100% sensitivity and 88.9% specificity for the diagnosis of orbital cavernous hemangioma, with a positive predictive value of 90.9% and a negative predictive value of 100%. 99mTc-RBC imaging is safe, easy to perform, and highly accurate in providing adequate clinical and surgical management. As a noninvasive and highly specific method for diagnosing orbital hemangioma, 99mTc-RBC scintigraphy can avoid more invasive imaging or biopsy.

  11. Evaluation of serum homocysteine, high-sensitivity CRP, and RBC folate in patients with alopecia areata

    Directory of Open Access Journals (Sweden)

    Maryam Yousefi

    2014-01-01

    Full Text Available Introduction: Alopecia areata (AA is a common type of hair loss with an autoimmune basis. As the role of homocysteine (Hcys, folate, and CRP has been considered in some autoimmune diseases. Objectives: To evaluate homocysteine, folate and CRP level in AA. Methods: This study was performed on 29 patients who had AA for at least 6 months affecting more than 20% of scalp, and 32 healthy controls. Levels of serum Hcys, blood high-sensitivity CRP, and RBC folate were measured in all subjects. Results: The mean level of RBC folate was significantly lower in the patient group than that in controls (P < 0.001. Also, the level of RBC folate was significantly lower in patients with extensive forms of disease (alopecia totalis/alopecia universalis in comparison with more localized form (patchy hair loss (P < 0.05. Patients with higher "Severity of Alopecia Total" (SALT score had lower RBC folate, as well. Serum Hcys and blood high-sensitivity CRP levels did not show a significant difference in two groups. Conclusion: Patients with alopecia areata have lower level of RBC folate which is in negative correlation with both severity and extension of AA.

  12. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  13. Tc-99m Labeled Red Blood Cell by Ultra Tag RBC Kit in Patients Suspected of Gastrointestinal Bleeding

    International Nuclear Information System (INIS)

    Pusuwan, Pawana; Leaungwutiwong, Suraphong; Tocharoenchai, Chiraporn; Chaiwatanarat, Tawatchai; Sirisatipoch, Sasitorn; Rajadara, Samart; Naktong, Thanyada; Thanyarak, Sucheera

    2001-06-01

    Twenty patients suspected of gastrointestinal bleeding who underwent Tc-99m labeled red blood cell (RBC) by ultraTag RBC kit at Division of Nuclear Medicine, Bumrungrad Hospital between January 2000 and December 2002 were studied. The histories of patients together with either endoscopic results or angiographic findings or pathological reports were used as gold standards. Two by Two decision matrix was used for data analysis and the sensitivity together with specificity were calculated. The results show that the sensitivity and specificity of Tc-99m labeled RBC by ultraTag RBC kit are 87.5% and 91.7%, respectively. We conclude that Tc-99m labeled RBC by ultraTag RBC kit gives high percentages of sensitivity and specificity. Moreover, the image quality is improved because of the absence of free Tc-99m pertechnetate uptake in the stomach in all patients

  14. Haemostatic function and biomarkers of endothelial damage before and after RBC transfusion in patients with haematologic disease

    DEFF Research Database (Denmark)

    Larsen, A M; Leinøe, E B; Johansson, P I

    2015-01-01

    function and the endothelium) to RBC transfusion. MATERIALS AND METHODS: Blood was sampled from patients with various transfusion-dependent haematologic diseases before 1 and 24 h after RBC transfusion. Primary and secondary haemostasis was evaluated by whole-blood impedance aggregometry (Multiplate....... Compared to before transfusion, patients had slightly reduced coagulability 1 h after RBC transfusion, assessed by TEG. However, transfusion of older RBC products (>14 days) was associated with increased coagulability (all P level of syndecan-1 increased slightly 24 h after transfusion (median....... The changes observed were small to moderate and the clinical relevance of these findings should be investigated in larger studies....

  15. Estimation of adult and neonatal RBC lifespans in anemic neonates using RBCs labeled at several discrete biotin densities.

    Science.gov (United States)

    Kuruvilla, Denison J; Widness, John A; Nalbant, Demet; Schmidt, Robert L; Mock, Donald M; An, Guohua; Veng-Pedersen, Peter

    2017-06-01

    Prior conclusions that autologous neonatal red blood cells (RBC) have substantially shorter lifespans than allogeneic adult RBCs were not based on direct comparison of autologous neonatal vs. allogeneic adult RBCs performed concurrently in the same infant. Biotin labeling of autologous neonatal RBCs and allogeneic adult donor RBCs permits concurrent direct comparison of autologous vs. allogeneic RBC lifespan. RBCs from 15 allogeneic adult donors and from 15 very-low-birth-weight (VLBW) neonates were labeled at separate biotin densities and transfused simultaneously into the 15 neonates. Two mathematical models that account for the RBC differences were employed to estimate lifespans for the two RBC populations. Mean ± SD lifespan for adult allogeneic RBC was 70.1 ± 19.1 d, which is substantially shorter than the 120 d lifespan of both autologous and adult allogeneic RBC in healthy adults. Mean ± SD lifespan for neonatal RBC was 54.2 ± 11.3 d, which is only about 30% shorter than that of the adult allogeneic RBCs. This study provides evidence that extrinsic environmental factors primarily determine RBC survival (e.g., small bore of the capillaries of neonates, rate of oxygenation/deoxygenation cycles) rather than factors intrinsic to RBC.

  16. Complete Blood Count Reference Intervals for Healthy Han Chinese Adults

    Science.gov (United States)

    Mu, Runqing; Guo, Wei; Qiao, Rui; Chen, Wenxiang; Jiang, Hong; Ma, Yueyun; Shang, Hong

    2015-01-01

    Background Complete blood count (CBC) reference intervals are important to diagnose diseases, screen blood donors, and assess overall health. However, current reference intervals established by older instruments and technologies and those from American and European populations are not suitable for Chinese samples due to ethnic, dietary, and lifestyle differences. The aim of this multicenter collaborative study was to establish CBC reference intervals for healthy Han Chinese adults. Methods A total of 4,642 healthy individuals (2,136 males and 2,506 females) were recruited from six clinical centers in China (Shenyang, Beijing, Shanghai, Guangzhou, Chengdu, and Xi’an). Blood samples collected in K2EDTA anticoagulant tubes were analyzed. Analysis of variance was performed to determine differences in consensus intervals according to the use of data from the combined sample and selected samples. Results Median and mean platelet counts from the Chengdu center were significantly lower than those from other centers. Red blood cell count (RBC), hemoglobin (HGB), and hematocrit (HCT) values were higher in males than in females at all ages. Other CBC parameters showed no significant instrument-, region-, age-, or sex-dependent difference. Thalassemia carriers were found to affect the lower or upper limit of different RBC profiles. Conclusion We were able to establish consensus intervals for CBC parameters in healthy Han Chinese adults. RBC, HGB, and HCT intervals were established for each sex. The reference interval for platelets for the Chengdu center should be established independently. PMID:25769040

  17. Low-grade inflammation is associated with lower haemoglobin levels in healthy individuals

    DEFF Research Database (Denmark)

    Kotzé, S R; Pedersen, O B; Petersen, M S

    2016-01-01

    status. Results: LGI was associated with lower haemoglobin (0·08 mm lower [0·12 g/dl], 95% confidence interval (CI): −0·11–0·05) and increased risk of low haemoglobin (OR = 1·22, 95% CI: 1·05–1·43) in non-smokers. Conversely, LGI was associated with higher haemoglobin in smokers (0·12 mm [0·19 g/dl], 95......% CI: 0·06–0·18). Conclusion: In this first study of LGI and haemoglobin in healthy individuals, there was a negative association between LGI and haemoglobin in non-smokers. The association was positive in smokers, probably because smoking leads to both increased inflammation and increased haemoglobin...

  18. Platelet count is associated with cardiovascular disease, cancer and mortality

    DEFF Research Database (Denmark)

    Vinholt, P J; Hvas, A M; Frederiksen, H

    2016-01-01

    count (100-450×10(9)/L) and mortality, development of future cardiovascular disease (myocardial infarction, ischaemic stroke, or peripheral vascular disease), venous thromboembolism, bleeding or cancer in the general population. MATERIAL AND METHODS: We conducted a register-based cohort study of 21......,252 adults (≥20years) from the Danish General Suburban Population Study (GESUS). Laboratory results from GESUS were linked to information from national registers regarding morbidity and death. Cox proportional hazard regression was conducted with adjustment for age, sex, smoking status, haemoglobin......, leukocyte count, C-reactive protein and Charlson comorbidity index. RESULTS: We found a U-shaped relationship between mortality and platelet count. Mortality was significantly increased for platelet count 300×10(9)/L. When categorizing platelet count using the interval 201-250×10(9)/L...

  19. Erythrocyte survival studies in lymphomas : a prognostic appraisal. [/sup 51/Cr-labelled RBC

    Energy Technology Data Exchange (ETDEWEB)

    Sanyal, B; Subrahmanyam, K; Pant, G C [Banaras Hindu Univ. (India). Inst. of Medical Sciences

    1977-08-01

    Erythrocyte survival studies using /sup 51/Cr-labelled RBC's were conducted using 20 patients with Hodgkin's lymphoma and 10 control subjects. Hepatic, splenic, and cardiac areas were monitored for rapid detection of hypersplenism. The findings are discussed in relation to the prognosis of the disease in the patients.

  20. Time dependent variation of human blood conductivity as a method for an estimation of RBC aggregation

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2008-01-01

    Roč. 39, č. 1 (2008), s. 69-78 ISSN 1386-0291 Institutional research plan: CEZ:AV0Z20600510 Keywords : RBC aggregation * blood conductivity * low shear rate viscometry Subject RIV: BO - Biophysics Impact factor: 1.814, year: 2008

  1. 40 CFR 35.2035 - Rotating biological contractor (RBC) replacement grants.

    Science.gov (United States)

    2010-07-01

    ... treatment works owner, the applicant, its engineers, contractors, equipment manufacturers or suppliers; (b) The RBC failure has significantly increased the project's capital or operation and maintenance costs; (c) The modification/replacement project meets all requirements of EPA's construction grant and other...

  2. A gene phylogeny of the red algae (Rhodophyta) based on plastid rbcL.

    Science.gov (United States)

    Freshwater, D W; Fredericq, S; Butler, B S; Hommersand, M H; Chase, M W

    1994-01-01

    A phylogeny for the Rhodophyta has been inferred by parsimony analysis of plastid rbcL sequences representing 81 species, 68 genera, 38 families, and 17 orders of red algae; rbcL encodes the large subunit of ribulose-1,5-bisphosphate carboxylase/oxygenase. Levels of sequence divergence among species, genera, and families are high in red algae, typically much greater than those reported for flowering plants. The Rhodophyta traditionally consists of one class, Rhodophyceae, and two subclasses, Bangiophycidae and Florideophycidae. The Bangiophycidae with three orders (Porphyridiales, Compsopogonales, and Bangiales) appears to be polyphyletic, and the Florideophycidae with 17 orders is monophyletic in this study. The current classification of the Florideophycidae based on ultrastructure of pit connections is supported. With the exception of the Rhodogorgonales, which appears to be misplaced, orders with one or two pit-plug cap layers (Hildenbrandiales, Corallinales, Acrochaetiales, Palmanales, Batrachospermales, and Nemaliales) terminate long branches of basal position within Florideophycidae in the most parsimonious rbcL tree. Orders that lack typical cap layers but possess a cap membrane are resolved as a monophyletic clade sister to the Ahnfeltiales. The large order Gigartinales, which is distributed among five rbcL clades, is polyphyletic. Families that possess typical carrageenan in their cell walls are resolved as a terminal clade containing two family complexes centered around the Solieriaceae and Gigartinaceae. PMID:8041781

  3. 77 FR 50487 - Application To Export Electric Energy; RBC Energy Services LP

    Science.gov (United States)

    2012-08-21

    ... DEPARTMENT OF ENERGY [OE Docket No. EA-328-A] Application To Export Electric Energy; RBC Energy... electric energy from the United States to Canada pursuant to section 202(e) of the Federal Power Act (FPA... to transmit electric energy from the United States to Canada as a power marketer for a five-year term...

  4. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    Science.gov (United States)

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  5. Rheological and electrical properties of polymeric nanoparticle solutions and their influence on RBC suspensions

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Koseva, N.; Kowalczyk, A.; Říha, Pavel; Ivanov, I.

    2014-01-01

    Roč. 24, č. 3 (2014), s. 35190 ISSN 1430-6395 Institutional support: RVO:67985874 Keywords : nanoparticles and RBC suspensions * poly(acrylic acid) * rheology * electrical conductivity Subject RIV: BK - Fluid Dynamics Impact factor: 1.078, year: 2014 http://www.ar.ethz.ch/TMPPDF/24308140293.696/ApplRheol_24_35190.pdf

  6. Development of a kit for RBC labelling with 99mTc and its clinic evaluation

    International Nuclear Information System (INIS)

    Marafuschi, A.M.; Nowotny, G.A.; Palcos, M.C.; Rotta, M. del C.

    1980-01-01

    A kit for labelling red blood cells (RBC) with 99m Tc based on a Tin Pyrophosphate mixture freeze-dried and a saline solution saturated with nitrogen has been prepared for spleen and placenta scanning, circulatory studies and blood volume determinations. The stannous tin is intended to reduce the 99m Tc pertechnetate, obtained either from generators or from solvent extraction, to the appropriate valence state suitable for labelling. The technique is as follows: Add to the heparinized blood sample the Tin-Pyrophosphate mixture dissolved in the saline solution. After five minutes incubation time at room temperature the plasma is discarded by centrifugation. Following the addition of the tracer activity to the separated RBC, the supernatant is discarded after a second centrifugation. Depending on the test to be performed, the RBC are either resuspended in saline solution for blood pool or circulation studies or denaturalized at 49.5 deg C for spleen scanning. The labelling yield (95-88%) and its stability has been checked by in vitro measurements, up to four hours after labelling. The biological distribution and spleen uptake have been determined in rats and rabbits. The developed method proved to be adequate for labelling RBC with good labelling retention. An interesting application is shown in babies with congenital cardiac defects and suspected absence of the spleen, where the scan gave a good image of the existing spleen. (author) [es

  7. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  8. Purification, crystallization and preliminary X-ray diffraction studies of parakeet (Psittacula krameri) haemoglobin

    OpenAIRE

    Jaimohan, S. M.; Naresh, M. D.; Arumugam, V.; Mandal, A. B.

    2009-01-01

    Parakeet (Psittacula krameri) haemoglobin has been purified and crystallized under low salt buffered conditions. Preliminary analysis of the crystal that belonged to monoclinic system (C2) is reported.

  9. Simulator for training operators of electric substation: an approach via RBC-Paraconsistent; Simulador para treinamento de operadores de subestacao eletrica: um enfoque via RBC-paraconsistente

    Energy Technology Data Exchange (ETDEWEB)

    Lambert-Torres, G.; Martins, H.G.; Coutinho, M.P.; Goulart, J.D.C.; Soares, F.M.A. [Universidade Federal de Itajuba (UNIFEI), MG (Brazil). Dept. de Engenharia Eletrica], Emails: germanoltorres@gmail.com, helgagonzaga@gmail.com, maurilio.coutinho@gmail.com, janaina157@yahoo.com.br, francis.azevedo@gmail.com

    2009-07-01

    This article presents a combination of two techniques applied artificial intelligence to solve problems to Restoration of an Electric Substation: Casebased Reasoning - CBR and the Four Values Annotated Paraconsistent Logic - 4vAPL. The process occurs in the connection functions of belief, disbelief, specialty and temporality to LPA4v in the retrieval of cases to determine process diagnostic of an RBC. The field of CBR is applied in a recovery of an electric substation. The LPA4v is the support applied in problems that have inconsistent information, partials and undefined. Thus this study is closer of the real situations.

  10. [Corrected count].

    Science.gov (United States)

    1991-11-27

    The data of the 1991 census indicated that the population count of Brazil fell short of a former estimate by 3 million people. The population reached 150 million people with an annual increase of 2%, while projections in the previous decade expected an increase of 2.48% to 153 million people. This reduction indicates more widespread use of family planning (FP) and control of fertility among families of lower social status as more information is being provided to them. However, the Ministry of Health ordered an investigation of foreign family planning organizations because it was suspected that women were forced to undergo tubal ligation during vaccination campaigns. A strange alliance of left wing politicians and the Roman Catholic Church alleges a conspiracy of international FP organizations receiving foreign funds. The FP strategies of Bemfam and Pro-Pater offer women who have little alternative the opportunity to undergo tubal ligation or to receive oral contraceptives to control fertility. The ongoing government program of distributing booklets on FP is feeble and is not backed up by an education campaign. Charges of foreign interference are leveled while the government hypocritically ignores the grave problem of 4 million abortions a year. The population is expected to continue to grow until the year 2040 and then to stabilize at a low growth rate of .4%. In 1980, the number of children per woman was 4.4 whereas the 1991 census figures indicate this has dropped to 3.5. The excess population is associated with poverty and a forsaken caste in the interior. The population actually has decreased in the interior and in cities with 15,000 people. The phenomenon of the drop of fertility associated with rural exodus is contrasted with cities and villages where the population is 20% less than expected.

  11. IMPACT OF HAEMOGLOBIN LEVELS ON OUTCOMES IN ACUTE CORONARY SYNDROME

    Directory of Open Access Journals (Sweden)

    Shrirang Kishor Bhurchandi

    2017-07-01

    Full Text Available BACKGROUND It is observed that anaemia is a common problem in patients hospitalised for acute coronary syndromes. There have been reports in worldwide studies of an association between anaemia and poor prognosis in patients with Acute Coronary Syndromes (ACS. MATERIALS AND METHODS All consecutive patients having ST-elevation myocardial infarction, non-ST elevation myocardial infarction and unstable angina who were admitted in medicine ward, Medicine Intensive Care Unit (MICU, Cardiology Department (CRD, Cardiovascular and Thoracic Surgery (CVTS Department and incidentally found in other departments of Acharya Vinoba Bhave Rural Hospital admitted from 1st November 2014 to 31st December 2015 at AVBRH. Total 200 patients were included in the study. RESULTS Our study showed an association between haemoglobin levels and mean age (p=0.0001, gender (p=0.0001, risk factors like smoking (p=0.035, tobacco (p=0.001 and Killip’s class I (p=0.0001, III (p=0.0001 and IV (p=0.0001. On distribution of the MACE’s during hospital stay stratified with Hb levels, the results of analysis by Chi-square test showed that there were statistically significant differences at various haemoglobin levels in MACE’s as post-infarction angina, heart failure, VT/VF and death (p<0.05 for all. On distribution of the MACE’s during follow up on 30th day and on 180th day stratified with Hb levels, the results of analysis by Chi-square test showed that there were statistically significant differences at various haemoglobin levels in MACE’s as post-infarction angina, re-infarction, heart failure, VT/VF and death (p<0.05 for all. CONCLUSION To conclude our study results, it was found during the study that anaemia as an important risk factor was strongly associated with major adverse outcomes in patients with ACS. Our study suggested that there was a statistically significant correlation between the low Hb levels and MACE’s (post-infarction angina, re-infarction, heart

  12. Reference Ranges of Reticulocyte Haemoglobin Content in Preterm and Term Infants: A Retrospective Analysis.

    Science.gov (United States)

    Lorenz, Laila; Peter, Andreas; Arand, Jörg; Springer, Fabian; Poets, Christian F; Franz, Axel R

    2017-01-01

    Despite iron supplementation, some preterm infants develop iron deficiency (ID). The optimal iron status parameter for early detection of ID has yet to be determined. To establish reference ranges for reticulocyte haemoglobin content (Ret-He) in preterm and term infants and to identify confounding factors. Retrospective analyses of Ret-He and complete blood count in infants with a clinically indicated blood sample obtained within 24 h after birth. Mean (SD) Ret-He was 30.7 (3.0) pg in very preterm infants with a gestational age (GA) of pH (r = -0.07). There was a slight variation in Ret-He with mode of delivery [normal vaginal delivery: 32.3 (3.2) pg, secondary caesarean section (CS): 31.4 (3.0) pg, instrumental delivery: 31.3 (2.7) pg and elective CS: 31.2 (2.8) pg]. GA at birth has a negligible impact on Ret-He, and the lower limit of the normal reference range in newborns within 24 h after birth can be set to 25 pg. Moreover, Ret-He seems to be a robust parameter which is not influenced by perinatal factors within the first 24 h after birth. © 2016 S. Karger AG, Basel.

  13. Ethylene, nitric oxide and haemoglobins in plant tolerance to flooding

    DEFF Research Database (Denmark)

    Mur, Luis A J; Gupta, Kapuganti J; Chakraborty, U

    2015-01-01

    -tolerant species Rumex palustris and the model plant Arabidopsis thaliana have been extensively exploited to reveal some key molecular events. Our groups have recently demonstrated that nitric oxide (NO) triggers the biosynthesis of ethylene during stress and that NO plays key roles in PCD and the hyponastic......As much as 12% of the world's soils may suffer excess water so that flooding is a major limiting factor on crop production in many areas. Plants attempt to deal with submergence by forming root aerenchyma to facilitate oxygen diffusion from the shoot to the root, initiating a hyponastic response....... This chapter will detail our understanding of the roles of ethylene, NO and haemoglobin in flooding stress....

  14. Non-symbiotic haemoglobins-What's happening beyond nitric oxide scavenging?

    Science.gov (United States)

    Hill, Robert D

    2012-01-01

    Non-symbiotic haemoglobins have been an active research topic for over 30 years, during which time a considerable portfolio of knowledge has accumulated relative to their chemical and molecular properties, and their presence and mode of induction in plants. While progress has been made towards understanding their physiological role, there remain a number of unanswered questions with respect to their biological function. This review attempts to update recent progress in this area and to introduce a hypothesis as to how non-symbiotic haemoglobins might participate in regulating hormone signal transduction. Advances have been made towards understanding the structural nuances that explain some of the differences in ligand association characteristics of class 1 and class 2 non-symbiotic haemoglobins. Non-symbiotic haemoglobins have been found to function in seed development and germination, flowering, root development and differentiation, abiotic stress responses, pathogen invasion and symbiotic bacterial associations. Microarray analyses under various stress conditions yield uneven results relative to non-symbiotic haemoglobin expression. Increasing evidence of the role of nitric oxide (NO) in hormone responses and the known involvement of non-symbiotic haemoglobins in scavenging NO provide opportunities for fruitful research, particularly at the cellular level. Circumstantial evidence suggests that non-symbiotic haemoglobins may have a critical function in the signal transduction pathways of auxin, ethylene, jasmonic acid, salicylic acid, cytokinin and abscisic acid. There is a strong need for research on haemoglobin gene expression at the cellular level relative to hormone signal transduction.

  15. Net haemoglobin increase from reinfusion of refrigerated vs. frozen red blood cells after autologous blood transfusions

    DEFF Research Database (Denmark)

    Ashenden, M; Mørkeberg, Jakob Sehested

    2011-01-01

    BACKGROUND AND OBJECTIVES  Two main blood storage procedures can be used for storing red blood cells: refrigeration and freezing. Nevertheless, the efficiency of these procedures measured as the increase in haemoglobin after reinfusion compared with baseline has never been examined. The main...... objective was to examine which storage procedure yielded the largest increase in circulating haemoglobin after reinfusion compared to baseline. MATERIALS AND METHODS  Equal volumes of blood from 15 men were withdrawn and stored either frozen or refrigerated as packed red blood cells. Serial measures...... of circulating haemoglobin by carbon monoxide rebreathing provided an opportunity to monitor recovery from anaemia, as well as the net increase in circulating haemoglobin after transfusion. RESULTS  The post-thaw yield of haemoglobin in the bags was 72% after refrigerated storage compared with only 52% after...

  16. Rotational dynamics of C60 in Na2RbC60

    International Nuclear Information System (INIS)

    Christides, C.; Prassides, K.; Neumann, D.A.; Copley, J.R.D.; Mizuki, J.; Tanigaki, K.; Hirosawa, I.; Ebbesen, T.W.

    1993-01-01

    We have measured the low-energy neutron inelastic-scattering (NIS) spectra of superconducting Na 2 RbC 60 in the temperature range 50-350 K. Well-defined librational peaks are observed at 50 K at 2.83(17) meV (FWHM = 1.7(5) meV). They soften and broaden with increasing temperature. Their behaviour mimics that found in solid C 60 and differs markedly from K 3 C 60 . The rotational barrier for C 60 reorientations in Na 2 RbC 60 is somewhat higher than in pristine C 60 and approximately half as large as in K 3 C 60 . An order-disorder transition is anticipated at a temperature higher than that found in C 60 . (orig.)

  17. Download this PDF file

    African Journals Online (AJOL)

    GB

    RBC) count, mean corpuscular haemoglobin ... immunologic memory, and when their numbers are diminished or their .... Table 3: Classification of anemia, red cell morphology and indices among newly diagnosed TB patients. MCHC(pg). Total.

  18. effect of thermal stress of short duration on the red blood cell

    African Journals Online (AJOL)

    Dr Ivanc

    2013-05-01

    May 1, 2013 ... of red blood cell count (RBC), haemoglobin concentration, packed cell volume ... The temperature at which stress begins to occur ..... of Barton (2002) that PCV is a measure of the cellular ..... Tufts B (eds) Fish respiration.

  19. rbcL gene sequences provide evidence for the evolutionary lineages of leptosporangiate ferns.

    OpenAIRE

    Hasebe, M; Omori, T; Nakazawa, M; Sano, T; Kato, M; Iwatsuki, K

    1994-01-01

    Pteriodophytes have a longer evolutionary history than any other vascular land plant and, therefore, have endured greater loss of phylogenetically informative information. This factor has resulted in substantial disagreements in evaluating characters and, thus, controversy in establishing a stable classification. To compare competing classifications, we obtained DNA sequences of a chloroplast gene. The sequence of 1206 nt of the large subunit of the ribulose-bisphosphate carboxylase gene (rbc...

  20. Experimental method for the study of blood and RBC suspension conductivity under flow

    Czech Academy of Sciences Publication Activity Database

    Antonova, N.; Říha, Pavel; Ivanov, I.

    2014-01-01

    Roč. 67, č. 7 (2014), s. 995-1004 ISSN 1310-1331 Grant - others:The Ministry of Education and Science of Bulgaria(BG) BG051PO001-3.3-05/0001; The Ministry of Education, Youth and Science of Bulgaria(BG) DO-805/2012 Institutional support: RVO:67985874 Keywords : viscometric flow * conductivity * blood/RBC suspension microstructural changes Subject RIV: BK - Fluid Dynamics Impact factor: 0.284, year: 2014

  1. Neem leaf extract as potential modifier of free radical interaction with RBC membrane

    International Nuclear Information System (INIS)

    Patil, Shilpa M.; Kulkarni, Satish G.; Rane, Charusheela

    2004-01-01

    Full text: Neem tree (Azadirachta indica) is well known as village pharmacy due to its multifaceted medicinal action in curing countless health problems. The leaf extract of Neem is known to purify blood by removing toxins and neutralizing free radicals. Using gamma irradiation as free radical generation process the efficacy of neem leaf extract in combating free radical attack on RBC membrane has been explored. The results narrating role of concentration and dose dependency in this radio modulation will be discussed

  2. Phylogeny and intraspecific variability of holoparasitic Orobanche (Orobanchaceae) inferred from plastid rbcL sequences.

    Science.gov (United States)

    Manen, Jean-François; Habashi, Christine; Jeanmonod, Daniel; Park, Jeong-Mi; Schneeweiss, Gerald M

    2004-11-01

    The rbcL sequences of 106 specimens representing 28 species of the four recognized sections of Orobanche were analyzed and compared. Most sequences represent pseudogenes with premature stop codons. This study confirms that the American lineage (sects. Gymnocaulis and Myzorrhiza) contains potentially functional rbcL-copies with intact open reading frames and low rates of non-synonymous substitutions. For the first time, this is also shown for a member of the Eurasian lineage, O. coerulescens of sect. Orobanche, while all other investigated species of sects. Orobanche and Trionychon contain pseudogenes with distorted reading frames and significantly higher rates of non-synonymous substitutions. Phylogenetic analyses of the rbcL sequences give equivocal results concerning the monophyly of Orobanche, and the American lineage might be more closely related to Boschniakia and Cistanche than to the other sections of Orobanche. Additionally, species of sect. Trionychon phylogenetically nest in sect. Orobanche. This is in concordance with results from other plastid markers (rps2 and matK), but in disagreement with other molecular (nuclear ITS), morphological, and karyological data. This might indicate that the ancestor of sect. Trionychon has captured the plastid genome, or parts of it, of a member of sect. Orobanche. Apart from the phylogenetically problematic position of sect. Trionychon, the phylogenetic relationships within sect. Orobanche are similar to those inferred from nuclear ITS data and are close to the traditional groupings traditionally recognized based on morphology. The intraspecific variation of rbcL is low and is neither correlated with intraspecific morphological variability nor with host range. Ancestral character reconstruction using parsimony suggests that the ancestor of O. sect. Orobanche had a narrow host range.

  3. The impact of prematurity on fetal haemoglobin and how it can bias measurement of glycated haemoglobin

    DEFF Research Database (Denmark)

    Zachariassen, Gitte; Esberg, Gitte; Grytter, Carl

    Background: The extent to which fetal hemoglobin (HbF) concentrations are increased in premature infants at the age of six to eight months is only sporadically described. The influence of HbF on measurement of glycated haemoglobin (HbA1c) has not been investigated in this population. Methods......: As part of a nutritional study on premature children, HbF and HbA1c were measured in 46 premature infants at the age of six to eight months. Results: Median HbF percentage was 10.3% (range 2.0 to 39.2%). In a multiple regression model only birth weight (P = 0.002) and post-conceptional age (P ... significantly from unadjusted values (4.4±0.4%), (P premature infants at six to eight months of age. The clinical implication of this work is a renewed attention on the prolonged Hb...

  4. Purification, crystallization and preliminary X-ray diffraction studies on avian haemoglobin from pigeon (Columba livia)

    International Nuclear Information System (INIS)

    Sathya Moorthy, Pon.; Neelagandan, K.; Balasubramanian, M.; Ponnuswamy, M. N.

    2009-01-01

    Crystallization of pigeon haemoglobin at low pH (5.5) and high ionic concentration (1 M) using the hanging-drop vapour-diffusion method is reported. Haemoglobin is a physiologically significant metalloprotein that is involved in the exchange of gases for sustaining life. The respiratory system of birds is unique and complex compared with that of mammals. Many investigations of avian haemoglobins have revealed the presence of inositol pentaphosphate (IP5), a principal allosteric effector that is involved in regulation of their function. Structural investigations of avian haemoglobins are presently not adequate to explain their function. Efforts have been made in this direction in order to understand the oxygen-binding affinity involved in adapting to hypoxia in avian haemoglobins. Fresh whole blood was collected from pigeon (Columba livia) and purified using a DEAE cellulose anion-exchange chromatographic column. Crystallization of pigeon haemoglobin was accomplished using the hanging-drop vapour-diffusion method using PEG 3350 as a precipitant in 50 mM sodium acetate buffer pH 5.5 with 1 M NaCl. Data collection was carried out using a MAR345 image-plate detector system. The crystals diffracted to 2 Å resolution. Pigeon haemoglobin crystallizes in a triclinic space group, with two whole biological molecules in the asymmetric unit and with unit-cell parameters a = 55.005, b = 65.528, c = 104.370 Å, α = 78.742, β = 89.819, γ = 65.320°

  5. Differences in iron acquisition from human haemoglobin among strains of Actinobacillus actinomycetemcomitans

    DEFF Research Database (Denmark)

    Hayashida, H.; Poulsen, Knud; Kilian, Mogens

    2002-01-01

    . actinomycetemcomitans strains examined harboured a single genomic sequence with homology to the hgpA gene encoding haemoglobin-binding protein A in Haemophilus influenzae. However, in all three strains belonging to the JP2 clone and in one serotype e strain hgpA was a pseudogene. Seven other strains possessed...... a functional hgpA gene which, according to insertion mutagenesis experiments, was responsible for the ability of these strains to utilize haemoglobin as a source of iron. Thus, the presence of an hgpA pseudogene and the inability to use human haemoglobin as an iron source discriminate the high-toxic JP2 clone...

  6. Multiple and Periodic Measurement of RBC Aggregation and ESR in Parallel Microfluidic Channels under On-Off Blood Flow Control

    Directory of Open Access Journals (Sweden)

    Yang Jun Kang

    2018-06-01

    Full Text Available Red blood cell (RBC aggregation causes to alter hemodynamic behaviors at low flow-rate regions of post-capillary venules. Additionally, it is significantly elevated in inflammatory or pathophysiological conditions. In this study, multiple and periodic measurements of RBC aggregation and erythrocyte sedimentation rate (ESR are suggested by sucking blood from a pipette tip into parallel microfluidic channels, and quantifying image intensity, especially through single experiment. Here, a microfluidic device was prepared from a master mold using the xurography technique rather than micro-electro-mechanical-system fabrication techniques. In order to consider variations of RBC aggregation in microfluidic channels due to continuous ESR in the conical pipette tip, two indices (aggregation index (AI and erythrocyte-sedimentation-rate aggregation index (EAI are evaluated by using temporal variations of microscopic, image-based intensity. The proposed method is employed to evaluate the effect of hematocrit and dextran solution on RBC aggregation under continuous ESR in the conical pipette tip. As a result, EAI displays a significantly linear relationship with modified conventional ESR measurement obtained by quantifying time constants. In addition, EAI varies linearly within a specific concentration of dextran solution. In conclusion, the proposed method is able to measure RBC aggregation under continuous ESR in the conical pipette tip. Furthermore, the method provides multiple data of RBC aggregation and ESR through a single experiment. A future study will involve employing the proposed method to evaluate biophysical properties of blood samples collected from cardiovascular diseases.

  7. Establishment of reference intervals for complete blood count parameters during normal pregnancy in Beijing.

    Science.gov (United States)

    Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui

    2017-11-01

    To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (Ppregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.

  8. Molecular evolution of rbcL in three gymnosperm families: identifying adaptive and coevolutionary patterns

    LENUS (Irish Health Repository)

    Sen, Lin

    2011-06-03

    Abstract Background The chloroplast-localized ribulose-1, 5-biphosphate carboxylase\\/oxygenase (Rubisco), the primary enzyme responsible for autotrophy, is instrumental in the continual adaptation of plants to variations in the concentrations of CO2. The large subunit (LSU) of Rubisco is encoded by the chloroplast rbcL gene. Although adaptive processes have been previously identified at this gene, characterizing the relationships between the mutational dynamics at the protein level may yield clues on the biological meaning of such adaptive processes. The role of such coevolutionary dynamics in the continual fine-tuning of RbcL remains obscure. Results We used the timescale and phylogenetic analyses to investigate and search for processes of adaptive evolution in rbcL gene in three gymnosperm families, namely Podocarpaceae, Taxaceae and Cephalotaxaceae. To understand the relationships between regions identified as having evolved under adaptive evolution, we performed coevolutionary analyses using the software CAPS. Importantly, adaptive processes were identified at amino acid sites located on the contact regions among the Rubisco subunits and on the interface between Rubisco and its activase. Adaptive amino acid replacements at these regions may have optimized the holoenzyme activity. This hypothesis was pinpointed by evidence originated from our analysis of coevolution that supported the correlated evolution between Rubisco and its activase. Interestingly, the correlated adaptive processes between both these proteins have paralleled the geological variation history of the concentration of atmospheric CO2. Conclusions The gene rbcL has experienced bursts of adaptations in response to the changing concentration of CO2 in the atmosphere. These adaptations have emerged as a result of a continuous dynamic of mutations, many of which may have involved innovation of functional Rubisco features. Analysis of the protein structure and the functional implications of such

  9. Seasonal changes in cell mediated immune responses to soluble Plasmodium falciparum antigens in children with haemoglobin AA and haemoglobin AS

    DEFF Research Database (Denmark)

    Abu-Zeid, Y A; Abdulhadi, N H; Theander, T G

    1992-01-01

    of tuberculin (PPD). The lymphoproliferative responses to SPAg of the paired PBMC samples showed 2 distinct seasonal changes in relation to the haemoglobin phenotype. In HbAA children, the lymphoproliferative responses to SPAg were suppressed during the malaria season. In contrast, they were enhanced in Hb......AS children during the malaria season. No distinct seasonal change in the response to PPD was found in relation to the haemoglobin phenotype. The study points to the role of the sickle cell trait in modulating the cellular immune responses to falciparum malaria....

  10. Point-of-care estimation of haemoglobin concentration in all age ...

    African Journals Online (AJOL)

    Point-of-care estimation of haemoglobin concentration in all age groups in clinical ... and the results were compared using standard scatter and difference plots. ... Hb measurements with a smaller sample volume, improved turnaround time, ...

  11. Haemoglobin concentrations appear to be lower in indigenous Greenlanders than in Danes

    DEFF Research Database (Denmark)

    Milman, N; Byg, K E; Mulvad, G

    2001-01-01

    's correlation coefficient (rs). RESULTS: Greenlanders: Haemoglobin levels were not correlated with age or consumption of traditional foods, and were not significantly different in the three residential areas. Mean haemoglobin was higher in men, 146+/-9.6 (SD) g/L, than in women, 132+/-9.6 g/L (p... haemoglobin in iron-replete men with serum ferritin >32 microg/L (n=104) was 146+/-9.3 g/L, and in iron-replete women (n=68) 133+/-10.4 g/L (pwomen 118 g/L (7.3 mmol/L). The prevalence of iron deficiency anaemia...... (i.e. ferritin women) was 0% in men, 2.78% in women women >50 yr of age. Danes: Mean haemoglobin in men was 154+/-10.0 g/L and in women 138+/-10.4 g/L (p

  12. Low resolution solution structure of the Apo form of Escherichia coli haemoglobin protease Hbp.

    NARCIS (Netherlands)

    scott, D.J.; Grossman, J.G.; Tame, J.R.H.; Byron, O.; Wilson, K.S.; Otto, B.R.

    2002-01-01

    We have studied the solution properties of the apo form of the haemoglobin protease or "haemoglobinase", Hbp, a principal component of an important iron acquisition system in pathogenic Escherichia coli. Experimental determination of secondary structure content from circular dichroism (CD)

  13. Purification, crystallization and preliminary X-ray diffraction studies on avian haemoglobin from pigeon (Columba livia)

    Science.gov (United States)

    Sathya Moorthy, Pon.; Neelagandan, K.; Balasubramanian, M.; Ponnuswamy, M. N.

    2009-01-01

    Haemoglobin is a physiologically significant metalloprotein that is involved in the exchange of gases for sustaining life. The respiratory system of birds is unique and complex compared with that of mammals. Many investigations of avian haemoglobins have revealed the presence of inositol pentaphosphate (IP5), a principal allosteric effector that is involved in regulation of their function. Structural investigations of avian haemoglobins are presently not adequate to explain their function. Efforts have been made in this direction in order to understand the oxygen-binding affinity involved in adapting to hypoxia in avian haemoglobins. Fresh whole blood was collected from pigeon (Columba livia) and purified using a DEAE cellulose anion-exchange chromatographic column. Crystallization of pigeon haemoglobin was accomplished using the hanging-drop vapour-diffusion method using PEG 3350 as a precipitant in 50 mM sodium acetate buffer pH 5.5 with 1 M NaCl. Data collection was carried out using a MAR345 image-plate detector system. The crystals diffracted to 2 Å resolution. Pigeon haemoglobin crystallizes in a triclinic space group, with two whole biological molecules in the asymmetric unit and with unit-cell parameters a = 55.005, b = 65.528, c = 104.370 Å, α = 78.742, β = 89.819, γ = 65.320°. PMID:19194000

  14. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  15. Three-dimensional counting of morphologically normal human red blood cells via digital holographic microscopy

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu; Lee, Yeon H.

    2015-01-01

    Counting morphologically normal cells in human red blood cells (RBCs) is extremely beneficial in the health care field. We propose a three-dimensional (3-D) classification method of automatically determining the morphologically normal RBCs in the phase image of multiple human RBCs that are obtained by off-axis digital holographic microscopy (DHM). The RBC holograms are first recorded by DHM, and then the phase images of multiple RBCs are reconstructed by a computational numerical algorithm. To design the classifier, the three typical RBC shapes, which are stomatocyte, discocyte, and echinocyte, are used for training and testing. Nonmain or abnormal RBC shapes different from the three normal shapes are defined as the fourth category. Ten features, including projected surface area, average phase value, mean corpuscular hemoglobin, perimeter, mean corpuscular hemoglobin surface density, circularity, mean phase of center part, sphericity coefficient, elongation, and pallor, are extracted from each RBC after segmenting the reconstructed phase images by using a watershed transform algorithm. Moreover, four additional properties, such as projected surface area, perimeter, average phase value, and elongation, are measured from the inner part of each cell, which can give significant information beyond the previous 10 features for the separation of the RBC groups; these are verified in the experiment by the statistical method of Hotelling's T-square test. We also apply the principal component analysis algorithm to reduce the dimension number of variables and establish the Gaussian mixture densities using the projected data with the first eight principal components. Consequently, the Gaussian mixtures are used to design the discriminant functions based on Bayesian decision theory. To improve the performance of the Bayes classifier and the accuracy of estimation of its error rate, the leaving-one-out technique is applied. Experimental results show that the proposed method can

  16. Evaluation of correlation between nucleated red blood cell count in term newborns and meconium-stained amniotic fluid

    Directory of Open Access Journals (Sweden)

    Esmaeilian L

    2001-09-01

    Full Text Available Considering the incidence of meconium-stained amniotic fluid (MSAF in newborns and its complications, and also based on indirect reports pointing out relationship between nucleated red blood cell (nRBC, as a marker of chronic hypoxia, and MSAF in term newborns, and in order to determine this relationship more accurately, this study was done on women with uncomplicated singleton term pregnancy that admitted for delivery at Shariati hospital in year 2000. After excluding confounding factors on nRBC, case group who includes infants with MSAF, and control group who have clear amniotic fluid were determined. Maternal age and parity, gestational age, birth weight, apgar score, neonatal out come, and FHR pattern as well as newborn hemoglobin values were evaluated. Venous cord blood was analyzed for nRBC counts per 100 WBC. Case and control groups were divided according to nRBC counts with cutoff point of 10 and then compared statistically. From the samples, 117 cases and 67 controls were evaluated. Maternal and neonatal factors were similar in two situations. Number of nRBC was 3.75±4.8 in control group and 12.04±11.7 in case group (P<0.01 and it was abnormal (>10 in 9 percent of newborns with clear fluid and 32 percent of MSAF (P<0.01. Cord blood nRBC count increased when meconium is passed intrauterine. This suggests that cases with MSAF may be at risk of chronic hypoxia. Cohort research is recommended to study the affect of delivery mode on the neonatal outcome in cases with MSAF and to evaluate the cause of fetal hypoxia in uncomplicated pregnancy with MSAF.

  17. Tissue Characterization of Lemna gibba rbcS Promoter%浮萍rbcS启动子组织特性研究

    Institute of Scientific and Technical Information of China (English)

    黄凤珍; 李倩; 王友如

    2015-01-01

    A new rbcS (ribulose-1,5-bisphosphate carboxylase small subunit) promoter with the size of 1 438 bp (named SSU5C promoter) was cloned from Lemna gibba. SSU5C promoter was fused with the GUS reporter gene to construct a plant binary vector (pSSU5C-IGUS), and introduced into duckweed by agrogacterium-mediated trans-formation. The transgenic plantlets were generated. This study was focused on the tissue characterization of SSU5C promoter. GUS staining showed that SSU5C promoter drove GUS to express in the green tissue in leaf, stem and petiole of T1 tobacco, whereas no GUS activity was observed in root. In reproductive organs, the GUS activity was observed in corolla lobes, anther and stigma, no GUS activity was observed in other parts. It was obvious that rbcS promoter can not only express in the green tissue, but also can express in reproductive organs. The results lay a good doundation for the application of SSU5C in plant genetic engineering.%SSU5C启动子(全长1438 bp)是从浮萍基因组中新克隆的一个rb c S (ribulose-1,5-bisphosphate carbo-xylase small subunit)启动子。本研究将 SSU5C 启动子与GUS基因融合,成功构建植物双元表达载p SSU5C-IGUS,并利用农杆菌介导法转化烟草,获得转基因植株,探究SSU5C启动子在烟草中的组织表达特点。GUS检测结果表明:在T1烟草的营养器官中,SSU5C启动子主要驱动GUS基因在烟草叶片和叶柄、茎等绿色组织中表达,而在根部不表达;在生殖器官中,GUS基因主要在花冠裂片以及花药和柱头中表达。本研究首次发现浮萍rb c S启动子不仅在绿色组织中表达,而且在生殖器官中的花冠裂片以及花药和柱头中表达,这一发现可为SSU5C启动子在植物基因工程中的应用奠定基础。

  18. Discriminatory power of rbcL barcode locus for authentication of some of United Arab Emirates (UAE) native plants.

    Science.gov (United States)

    Maloukh, Lina; Kumarappan, Alagappan; Jarrar, Mohammad; Salehi, Jawad; El-Wakil, Houssam; Rajya Lakshmi, T V

    2017-06-01

    DNA barcoding of United Arab Emirates (UAE) native plants is of high practical and scientific value as the plants adapt to very harsh environmental conditions that challenge their identification. Fifty-one plant species belonged to 22 families, 2 monocots, and 20 eudicots; a maximum number of species being legumes and grasses were collected. To authenticate the morphological identification of the wild plant taxa, rbcL and matK regions were used in the study. The primer universality and discriminatory power of rbcL is 100%, while it is 35% for matK locus for these plant species. The sequences were submitted to GenBank; accession numbers were obtained for all the rbcL sequences and for 6 of matK sequences. We suggest rbcL as a promising barcode locus for the tested group of 51 plants. In the present study, an inexpensive, simple method of identification of rare desert plant taxa through rbcL barcode is being reported.

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  20. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  1. Purification, crystallization and preliminary X-ray analysis of haemoglobin from ostrich (Struthio camelus)

    International Nuclear Information System (INIS)

    Sundaresan, S. S.; Ramesh, P.; Sivakumar, K.; Ponnuswamy, M. N.

    2009-01-01

    Purification, crystallization and preliminary X-ray analysis of haemoglobin from ostrich (Struthio camelus) has been carried out under 293 K temperature conditions. The ostrich is a large flightless bird which contains inositol tetrakisphosphate in erythrocytes and its whole blood oxygen affinity is higher. Efforts have been made to explore the structure–function relationship of ostrich heamoglobin. Haemoglobin is a tetrameric protein that carries oxygen from the lungs to tissues and carbon dioxide from tissues back to the lungs. The oxygen-binding properties of haemoglobin are regulated through the binding of allosteric effectors. The respiratory system of avian species is unique and complex in nature when compared with that of mammals. In avian species, inositol pentaphosphate (inositol-P 5 ) is present in the erythrocytes of the adult and is thought to be the major factor responsible for the relatively high oxygen affinity of the whole blood. The ostrich (Struthio camelus) is a large flightless bird which contains inositol tetrakisphosphate (inositol-P 4 ) in its erythrocytes and its whole blood oxygen affinity is higher. Efforts have been made to explore the structure–function relationship of ostrich haemoglobin. Ostrich haemoglobin was purified using ion-exchange chromatography. Haemoglobin crystals were grown by the hanging-drop vapour-diffusion method using PEG 3350 as the precipitant in 50 mM phosphate buffer pH 7.2. Data were collected using a MAR345 image-plate detector system. The crystals of ostrich haemoglobin diffracted to 2.2 Å resolution. They belonged to the orthorhombic space group P2 1 2 1 2 1 with one whole biological molecule in the asymmetric unit; the unit-cell parameters were a = 80.93, b = 81.68, c = 102.05 Å

  2. Maternal haemoglobin and short-term neonatal outcome in preterm neonates.

    Directory of Open Access Journals (Sweden)

    Elodie Savajols

    Full Text Available To determine whether there is a significant association between maternal haemoglobin measured before delivery and short-term neonatal outcome in very preterm neonates.We included prospectively all live births occurring from 25 to 32+6 weeks of gestation in a tertiary care centre between January 1(st 2009 and December 31(st 2011. Outborn infants and infants presenting with lethal malformations were excluded. Three hundred and thirty-nine mothers and 409 infants met the inclusion criteria. For each mother-infant pair a prospective record of epidemiologic data was performed and maternal haemoglobin concentration recorded within 24 hours before delivery was retrospectively researched. Maternal haemoglobin was divided into quartiles with the second and the third one regarded as reference as they were composed of normal haemoglobin values. Short-term outcome was defined as poor in case of death during hospital stay and/or grades III/IV intraventricular haemorrhage and/or periventricular leukomalacia and/or necessity of ventriculoperitoneal shunt.The global rate of poor short-term neonatal outcome was 11.4% and was significantly associated with low maternal haemoglobin values. This association remained significant after adjustment for antenatal corticosteroids therapy, gestational age, parity, mechanism of preterm birth, mode of delivery and birth weight (aOR = 2.97 CI 95% [1.36-6.47]. There was no relation between short-term neonatal outcome and high maternal haemoglobin concentration values.We show that low maternal haemoglobin concentration at delivery is an independent risk factor for poor short-term neonatal outcome in very preterm neonates. This study is one of the first to show such an association within the preterm population.

  3. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  4. A Survey Of Normal Haematological Variables Among Adults In ...

    African Journals Online (AJOL)

    Main outcome measures: Haematological values of the following blood parameters were determined; Haemoglobin (Hb), Haematocrit(PCV), Erythrocyte (RBC) count, Leucocyte (WBC) count, Platelet count and the differential cells count (consisting of the Neutrophils, Eosinophils, Basophiles, Lymphocytes and Monocyte ...

  5. Physiologic Impact of Circulating RBC Microparticles upon Blood-Vascular Interactions

    Directory of Open Access Journals (Sweden)

    Ahmed S. Said

    2018-01-01

    Full Text Available Here, we review current data elucidating the role of red blood cell derived microparticles (RMPs in normal vascular physiology and disease progression. Microparticles (MPs are submicron-size, membrane-encapsulated vesicles derived from various parent cell types. MPs are produced in response to numerous stimuli that promote a sequence of cytoskeletal and membrane phospholipid changes and resulting MP genesis. MPs were originally considered as potential biomarkers for multiple disease processes and more recently are recognized to have pleiotropic biological effects, most notably in: promotion of coagulation, production and handling of reactive oxygen species, immune modulation, angiogenesis, and in initiating apoptosis. RMPs, specifically, form normally during RBC maturation in response to injury during circulation, and are copiously produced during processing and storage for transfusion. Notably, several factors during RBC storage are known to trigger RMP production, including: increased intracellular calcium, increased potassium leakage, and energy failure with ATP depletion. Of note, RMP composition differs markedly from that of intact RBCs and the nature/composition of RMP components are affected by the specific circumstances of RMP genesis. Described RMP bioactivities include: promotion of coagulation, immune modulation, and promotion of endothelial adhesion as well as influence upon vasoregulation via influence upon nitric oxide (NO bioavailability. Of particular relevance, RMPs scavenge NO more avidly than do intact RBCs; this physiology has been proposed to contribute to the impaired oxygen delivery homeostasis that may be observed following transfusion. In summary, RMPs are submicron particles released from RBCs, with demonstrated vasoactive properties that appear to disturb oxygen delivery homeostasis. The clinical impact of RMPs in normal and patho-physiology and in transfusion recipients is an area of continued investigation.

  6. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  7. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  8. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  9. Risk factors and consequences of maternal anaemia and elevated haemoglobin levels during pregnancy: a population-based prospective cohort study.

    Science.gov (United States)

    Gaillard, Romy; Eilers, Paul H C; Yassine, Siham; Hofman, Albert; Steegers, Eric A P; Jaddoe, Vincent W V

    2014-05-01

    To determine sociodemographic and life style-related risk factors and trimester specific maternal, placental, and fetal consequences of maternal anaemia and elevated haemoglobin levels in pregnancy. In a population-based prospective cohort study of 7317 mothers, we measured haemoglobin levels in early pregnancy [gestational age median 14.4 weeks (inter-quartile-range 12.5-17.5)]. Anaemia (haemoglobin ≤11 g/dl) and elevated haemoglobin levels (haemoglobin ≥13.2 g/dl) were defined according to the WHO criteria. Maternal blood pressure, placental function and fetal growth were measured in each trimester. Data on gestational hypertensive disorders and birth outcomes was collected from hospitals. Older maternal age, higher body mass index, primiparity and European descent were associated with higher haemoglobin levels (P pregnancy (mean differences 5.1 mmHg, 95% confidence interval [CI] 3.8, 6.5 and 4.1 mmHg, 95% CI 3.0, 5.2, respectively) and with a higher risk of third trimester uterine artery notching (RR 1.3, 95% CI 1.0, 1.7). As compared with maternal normal haemoglobin levels, not anaemia, but elevated haemoglobin levels were associated with fetal head circumference, length, and weight growth restriction from third trimester onwards (P pregnancy. Elevated haemoglobin levels are associated with increased risks of maternal, placental, and fetal complications. © 2014 John Wiley & Sons Ltd.

  10. [Effects of HiLo for two weeks on erythrocyte immune adhesion and leukocyte count of swimmers].

    Science.gov (United States)

    Zhao, Yong-Cai; Gao, Bing-Hong; Wu, Ge-Lin; Zhang, Jiu-Li

    2012-07-01

    To investigate the effects of living high-training low (HiLo) on innate immunity in blood of elite swimmers. Six female swimmers undertook HiLo for two weeks, erythrocyte adhesion function and counts of leukocyte were tested in different time of training period. Red blood cell C3b receptor ring rate (RBC-C3bRR) decreased and red blood cell immune complex matter ring rate (RBC-ICR) increased significantly (P < 0.05), the two markers returned to base line 1 week after training. Counts of leukocyte and granulocyte decreased significantly (P < 0.05), and they recovered 1 week after training; Counts of lymphocyte and monocyte decreased without significance during training and did not recovered after training. Immunity of erythrocyte and granulocyte decreased quickly, but lymphocyte and monocyte recovered slowly, swimmers were adaptive to the training.

  11. Haemoglobin variants may cause significant differences in haemoglobin A1c as measured by high-performance liquid chromatography and enzymatic methods in diabetic patients: a cross-sectional study.

    Science.gov (United States)

    Otabe, Shuichi; Nakayama, Hitomi; Ohki, Tsuyoshi; Soejima, Eri; Tajiri, Yuji; Yamada, Kentaro

    2017-07-01

    Background We aimed to determine whether the discrepancy between haemoglobin A1c values determined by high-performance liquid chromatography and enzymatic haemoglobin A1c measurements in diabetic patients was clinically relevant. Methods We randomly recruited 1421 outpatients undergoing diabetic treatment and follow-up who underwent at least three haemoglobin A1c measurements between April 2014 and March 2015 at our clinic. In 6369 samples, haemoglobin A1c was simultaneously measured by HA-8160 and MetaboLead (enzymatic assay), and the values were compared. Results haemoglobin A1c measurements by high-performance liquid chromatography and enzymatic assay were strongly correlated (correlation coefficient: 0.9828, linear approximation curve y = 0.9986x - 0.2507). Mean haemoglobin A1c (6.8 ± 1.0%) measured by high-performance liquid chromatography was significantly higher than that measured by enzymatic assay (6.5 ± 1.0%, P liquid chromatography than those from enzymatic assay. Of these, three had Hb Toranomon [β112 (G14) Cys→Trp]. The fourth had Hb Ube-2 [α68 (E17) Asn→Asp]. One other subject presented consistently higher haemoglobin A1c values (>1%) by high-performance liquid chromatography than those from enzymatic assay and was diagnosed with a -77 (T > C) mutation in the δ-globin gene. These unrelated asymptomatic subjects had normal erythrocyte profiles, without anaemia. Conclusions We showed that haemoglobin A1c values measured by high-performance liquid chromatography were significantly higher than those measured by enzymatic assay in diabetic subjects. However, when an oversized deviation (>0.7%) between glycaemic control status and haemoglobin A1c is apparent, clinicians should check the methods used to measure haemoglobin A1c and consider the possible presence of a haemoglobin variant.

  12. How Noninvasive Haemoglobin Measurement with Pulse CO-Oximetry Can Change Your Practice: An Expert Review

    Directory of Open Access Journals (Sweden)

    Gregor Lindner

    2013-01-01

    Full Text Available Trauma related haemorrhagic anaemia is rarely diagnosed by physical examination alone but typically includes measurement of blood haemoglobin, one of the most frequently ordered laboratory tests. Recently, noninvasive technologies have been developed that allow haemoglobin to be measured immediately without the need for intravenous access or having to take venous, arterial, or capillary blood. Moreover, with these technologies haemoglobin can be continuously measured in patients with active bleeding, to guide the start and stop of blood transfusions and to detect occult bleeding. Recent studies on the accuracy of the devices showed promising results in terms of accuracy of hemoglobin measurement compared to laboratory determination. The present review gives an overview on the technology itself and reviews the current literature on the subject.

  13. Hepcidin plasma levels are not associated with changes in haemoglobin in early rheumatoid arthritis patients

    DEFF Research Database (Denmark)

    Østgård, R D; Glerup, H; Jurik, A G

    2017-01-01

    Objective: A reduction in haemoglobin level is a frequent complication among rheumatoid arthritis (RA) patients. Hepcidin has been linked to disturbed erythropoiesis. The objective of this study was to investigate the longitudinal changes in hepcidin in patients with early RA. Method: Hepcidin...... with disease-modifying anti-rheumatic drugs (DMARDs) and with additional adalimumab (ADA, n = 42) or placebo (PLA, n = 38) during 52 weeks, using a treat-to-target strategy, aiming for a 28-joint Disease Activity Score (DAS28) levels [median (interquartile range)] were 9...... = 0.48, p levels of haemoglobin and hepcidin at baseline or during the 52 week follow-up. No change in haemoglobin levels was seen as a function of hepcidin changes. In a mixed statistical model, no single factor was connected with the regulation...

  14. Crystallization and diffraction patterns of the oxy and cyano forms of the Lucina pectinata haemoglobins complex

    International Nuclear Information System (INIS)

    Ruiz-Martínez, Carlos R.; Nieves-Marrero, Carlos A.; Estremera-Andújar, Rafael A.; Gavira, José A.; González-Ramírez, Luis A.; López-Garriga, Juan; García-Ruiz, Juan M.

    2008-01-01

    The native oxygen-carrier haemoglobins complex (HbII–III) is composed of haemoglobin II (HbII) and haemoglobin III (HbIII), which are found in the ctenidia tissue of the bivalve mollusc Lucina pectinata. This protein complex was isolated and purified from its natural source and crystallized using the vapour-diffusion and capillary counter-diffusion methods. The native oxygen-carrier haemoglobins complex (HbII–III) is composed of haemoglobin II (HbII) and haemoglobin III (HbIII), which are found in the ctenidia tissue of the bivalve mollusc Lucina pectinata. This protein complex was isolated and purified from its natural source and crystallized using the vapour-diffusion and capillary counter-diffusion methods. Oxy and cyano derivatives of the complex crystallized using several conditions, but the best crystals in terms of quality and size were obtained from sodium formate pH 5 using the counter-diffusion method in a single capillary. Crystals of the oxy and cyano complexes, which showed a ruby-red colour and nonsingular prismatic shapes, scattered X-rays to resolution limits of 2.15 and 2.20 Å, respectively, using a 0.886 Å synchrotron-radiation source. The crystals belonged to the tetragonal system, space group P4 2 2 1 2, with unit-cell parameters a = b = 74.07, c = 152.07 and a = b = 73.83, c = 152.49 Å for the oxy and cyano complexes, respectively. The asymmetric unit of both crystals is composed of a single copy of the heterodimer, with Matthew coefficients (V M ) of 3.08 and 3.06 Å 3 Da −1 for the oxy and cyano complexes, respectively, which correspond to a solvent content of approximately 60.0% by volume

  15. Decision Tree Algorithm-Generated Single-Nucleotide Polymorphism Barcodes of rbcL Genes for 38 Brassicaceae Species Tagging.

    Science.gov (United States)

    Yang, Cheng-Hong; Wu, Kuo-Chuan; Chuang, Li-Yeh; Chang, Hsueh-Wei

    2018-01-01

    DNA barcode sequences are accumulating in large data sets. A barcode is generally a sequence larger than 1000 base pairs and generates a computational burden. Although the DNA barcode was originally envisioned as straightforward species tags, the identification usage of barcode sequences is rarely emphasized currently. Single-nucleotide polymorphism (SNP) association studies provide us an idea that the SNPs may be the ideal target of feature selection to discriminate between different species. We hypothesize that SNP-based barcodes may be more effective than the full length of DNA barcode sequences for species discrimination. To address this issue, we tested a r ibulose diphosphate carboxylase ( rbcL ) S NP b arcoding (RSB) strategy using a decision tree algorithm. After alignment and trimming, 31 SNPs were discovered in the rbcL sequences from 38 Brassicaceae plant species. In the decision tree construction, these SNPs were computed to set up the decision rule to assign the sequences into 2 groups level by level. After algorithm processing, 37 nodes and 31 loci were required for discriminating 38 species. Finally, the sequence tags consisting of 31 rbcL SNP barcodes were identified for discriminating 38 Brassicaceae species based on the decision tree-selected SNP pattern using RSB method. Taken together, this study provides the rational that the SNP aspect of DNA barcode for rbcL gene is a useful and effective sequence for tagging 38 Brassicaceae species.

  16. Long-chain PUFA in Granulocytes, Mononuclear Cells, and RBC in Patients With Cystic Fibrosis: Relation to Liver Disease

    DEFF Research Database (Denmark)

    Jorgensen, Marianne H.; Ott, Peter; Michaelsen, Kim F.

    2012-01-01

    -related liver disease were matched with 20 CF patients without. Blood samples were analysed for liver biochemistry and haematology. Granulocytes, mononuclear cells, and RBC were separated by density gradient centrifugation, and fatty acid composition was measured by gas chromatography. Hepatic ultrasound...

  17. Role of the duplicated CCAAT box region in γ-globin gene regulation and hereditary persistence of fetal haemoglobin.

    NARCIS (Netherlands)

    A. Ronchi (Antonella); M. Berry (Meera); S. Raguz (Selina); A.M.A. Imam (Ali); N. Yannoutsos (Nikos); S. Ottolenghi (Sergio); F.G. Grosveld (Frank); N.O. Dillon (Niall)

    1996-01-01

    textabstractHereditary persistence of fetal haemoglobin (HPFH) is a clinically important condition in which a change in the developmental specificity of the gamma-globin genes results in varying levels of expression of fetal haemoglobin in the adult. The condition is benign and can significantly

  18. rbcL gene sequences provide evidence for the evolutionary lineages of leptosporangiate ferns.

    Science.gov (United States)

    Hasebe, M; Omori, T; Nakazawa, M; Sano, T; Kato, M; Iwatsuki, K

    1994-06-07

    Pteriodophytes have a longer evolutionary history than any other vascular land plant and, therefore, have endured greater loss of phylogenetically informative information. This factor has resulted in substantial disagreements in evaluating characters and, thus, controversy in establishing a stable classification. To compare competing classifications, we obtained DNA sequences of a chloroplast gene. The sequence of 1206 nt of the large subunit of the ribulose-bisphosphate carboxylase gene (rbcL) was determined from 58 species, representing almost all families of leptosporangiate ferns. Phlogenetic trees were inferred by the neighbor-joining and the parsimony methods. The two methods produced almost identical phylogenetic trees that provided insights concerning major general evolutionary trends in the leptosporangiate ferns. Interesting findings were as follows: (i) two morphologically distinct heterosporous water ferns, Marsilea and Salvinia, are sister genera; (ii) the tree ferns (Cyatheaceae, Dicksoniaceae, and Metaxyaceae) are monophyletic; and (iii) polypodioids are distantly related to the gleichenioids in spite of the similarity of their exindusiate soral morphology and are close to the higher indusiate ferns. In addition, the affinities of several "problematic genera" were assessed.

  19. OpenRBC: Redefining the Frontier of Red Blood Cell Simulations at Protein Resolution

    Science.gov (United States)

    Tang, Yu-Hang; Lu, Lu; Li, He; Grinberg, Leopold; Sachdeva, Vipin; Evangelinos, Constantinos; Karniadakis, George

    We present a from-scratch development of OpenRBC, a coarse-grained molecular dynamics code, which is capable of performing an unprecedented in silico experiment - simulating an entire mammal red blood cell lipid bilayer and cytoskeleton modeled by 4 million mesoscopic particles - on a single shared memory node. To achieve this, we invented an adaptive spatial searching algorithm to accelerate the computation of short-range pairwise interactions in an extremely sparse 3D space. The algorithm is based on a Voronoi partitioning of the point cloud of coarse-grained particles, and is continuously updated over the course of the simulation. The algorithm enables the construction of a lattice-free cell list, i.e. the key spatial searching data structure in our code, in O (N) time and space space with cells whose position and shape adapts automatically to the local density and curvature. The code implements NUMA/NUCA-aware OpenMP parallelization and achieves perfect scaling with up to hundreds of hardware threads. The code outperforms a legacy solver by more than 8 times in time-to-solution and more than 20 times in problem size, thus providing a new venue for probing the cytomechanics of red blood cells. This work was supported by the Department of Energy (DOE) Collaboratory on Mathematics for Mesoscopic Model- ing of Materials (CM4). YHT acknowledges partial financial support from an IBM Ph.D. Scholarship Award.

  20. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  1. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  3. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  4. Reliability and validity of non-invasive determined haemoglobin mass and blood volumes

    DEFF Research Database (Denmark)

    Fagoni, Nazzareno; Andersen, Andreas Breenfeldt; Oberholzer, Laura

    2018-01-01

    INTRODUCTION: The carbon monoxide (CO) rebreathing method used for the determination of haemoglobin mass (Hbmass ) is associated with blood sample analysis (in this study: Radiometer ABL800). As an alternative hereto the aim of the present study was to evaluate the use of a portable and non-invas...

  5. Serum Iron and Haemoglobin Estimation in Oral Submucous Fibrosis and Iron Deficiency Anaemia: A Diagnostic Approach.

    Science.gov (United States)

    Bhardwaj, Divya; Dinkar, Ajit D; Satoskar, Sujata K; Desai, Sapna Raut

    2016-12-01

    Oral Submucous Fibrosis (OSMF) is a premalignant condition with potential malignant behaviour characterized by juxta-epithelial fibrosis of the oral cavity. In the process of collagen synthesis, iron gets utilized, by the hydroxylation of proline and lysine, leading to decreased serum iron levels. The trace element like iron is receiving much attention in the detection of oral cancer and precancerous condition like OSMF as it was found to be significantly altered in these conditions. The aim of this study was to compare the haemoglobin and serum iron values of OSMF subjects with that of iron deficiency anaemia subjects. Total of 120 subjects were included, 40 subjects with the OSMF, 40 with the iron deficiency anemia without tobacco chewing habit, 40 healthy control subjects without OSMF and iron deficiency anaemia. A total of 5ml of venous blood was withdrawn from all the subjects and serum iron and haemoglobin levels were estimated for all the subjects. Estimation of iron was done using Ferrozine method and haemoglobin by Sahli's method. The statistical method applied were Kruskal Wallis, Mann Whitney and Pearson correlation coefficient test. There was a statistically significant difference in serum iron and haemoglobin level in all three groups (pauxillary test in assessment of prognosis of the disease.

  6. Nutrient Patterns Associated with Fasting Glucose and Glycated Haemoglobin Levels in a Black South African Population

    NARCIS (Netherlands)

    Chikowore, T.; Pisa, P.T.; Zyl, van Tertia; Feskens, E.J.M.; Wentzel-Viljoen, E.; Conradie, K.R.

    2017-01-01

    Type 2 diabetes (T2D) burden is increasing globally. However, evidence regarding nutrient patterns associated with the biomarkers of T2D is limited. This study set out to determine the nutrient patterns associated with fasting glucose and glycated haemoglobin the biomarkers of T2D. Factor analysis

  7. Haemoglobin modulates salicylate and jasmonate/ethylene-mediated resistance mechanisms against pathogens

    DEFF Research Database (Denmark)

    Mur, Luis A J; Sivakumaran, Anushen; Mandon, Julien

    2012-01-01

    Nitric oxide (NO) plays a role in defence against hemibiotrophic pathogens mediated by salicylate (SA) and also necrotrophic pathogens influenced by jasmonate/ethylene (JA/Et). This study examined how NO-oxidizing haemoglobins (Hb) encoded by GLB1, GLB2, and GLB3 in Arabidopsis could influence both...

  8. Inositol-P6 induced structural changes in duck major haemoglobin

    African Journals Online (AJOL)

    Bamiji Babalola

    2011-11-02

    Nov 2, 2011 ... of duck (Anas platyrhinchos) have been carried out in the presence of ... dependence profile of the apparent second-order rate constant of both oxy- and ... Key words: 5,5‟-Dithiobis (2-nitrobenzoate), duck, haemoglobin, inositol-P6, sulphydryl group. ... Saigo, 1999), thereby making it possible to detect the.

  9. Glycated haemoglobin may in future be reported as estimated mean blood glucose concentration--secondary publication

    DEFF Research Database (Denmark)

    Borg, R.; Nerup, J.; Nathan, D.M.

    2009-01-01

    Glycated haemoglobin (HbA 1c ) is widely used to determine levels of chronic glycaemia, to judge the adequacy of diabetes treatment and to adjust therapy. HbA 1c results are expressed as the percentage of HbA that is glycated. Day-to-day management is guided by self-monitoring of capillary glucose...

  10. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    Science.gov (United States)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  11. DNA Barcoding the Canadian Arctic Flora: Core Plastid Barcodes (rbcL + matK) for 490 Vascular Plant Species

    Science.gov (United States)

    Saarela, Jeffery M.; Sokoloff, Paul C.; Gillespie, Lynn J.; Consaul, Laurie L.; Bull, Roger D.

    2013-01-01

    Accurate identification of Arctic plant species is critical for understanding potential climate-induced changes in their diversity and distributions. To facilitate rapid identification we generated DNA barcodes for the core plastid barcode loci (rbcL and matK) for 490 vascular plant species, representing nearly half of the Canadian Arctic flora and 93% of the flora of the Canadian Arctic Archipelago. Sequence recovery was higher for rbcL than matK (93% and 81%), and rbcL was easier to recover than matK from herbarium specimens (92% and 77%). Distance-based and sequence-similarity analyses of combined rbcL + matK data discriminate 97% of genera, 56% of species, and 7% of infraspecific taxa. There is a significant negative correlation between the number of species sampled per genus and the percent species resolution per genus. We characterize barcode variation in detail in the ten largest genera sampled (Carex, Draba, Festuca, Pedicularis, Poa, Potentilla, Puccinellia, Ranunculus, Salix, and Saxifraga) in the context of their phylogenetic relationships and taxonomy. Discrimination with the core barcode loci in these genera ranges from 0% in Salix to 85% in Carex. Haplotype variation in multiple genera does not correspond to species boundaries, including Taraxacum, in which the distribution of plastid haplotypes among Arctic species is consistent with plastid variation documented in non-Arctic species. Introgression of Poa glauca plastid DNA into multiple individuals of P. hartzii is problematic for identification of these species with DNA barcodes. Of three supplementary barcode loci (psbA–trnH, psbK–psbI, atpF–atpH) collected for a subset of Poa and Puccinellia species, only atpF–atpH improved discrimination in Puccinellia, compared with rbcL and matK. Variation in matK in Vaccinium uliginosum and rbcL in Saxifraga oppositifolia corresponds to variation in other loci used to characterize the phylogeographic histories of these Arctic-alpine species. PMID

  12. The influence of sex on the haematological values of apparently ...

    African Journals Online (AJOL)

    Blood samples were collected from fifty apparently healthy adult Sahel goats, twenty five each of male and female in Maiduguri to assess the influence of sex on their haematology. The red blood cell (RBC) counts, white blood cell (WBC) counts, haemoglobin (Hb) concentration, packed cell volume (PCV), platelet counts, ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  15. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  16. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  17. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  18. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  1. Delimiting the species Neosiphonia yendoi (Rhodomelaceae, Rhodophyta) based on COI and rbcL genetic variation in Korea and Japan

    Science.gov (United States)

    Kim, Byeongseok; Yang, Mi Yeon; Kim, Myung Sook

    2016-09-01

    Although the marine red algal genus Neosiphonia is well characterized, many species of Neosiphonia are poorly understood. To correctly define the species delimitation of Neosiphonia yendoi using genetic variation, owing to the confusion over identification with " N. sphaerocarpa" from Korea, we investigated intensively the haplotype network of the mitochondrial COI and the plastid rbcL genes of specimens collected from Korea and Japan. The molecular analyses indicated that specimens collected in different sites of Korea and Japan belong to the same species, Neosiphonia yendoi and " Neosiphonia sphaerocarpa" from Korea, which is distinguished from N. sphaerocarpa from Florida and is allied with N. yendoi collected from the type locality, Muroran of Japan. A total of 29 COI and 13 rbcL haplotypes were found and the COI haplotype network shows evidence of a clear break between specimens from Jeju Island and all other locations of Korea, suggesting the possibility of cryptic diversity within N. yendoi.

  2. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  3. The relationship between helminth infections and low haemoglobin levels in Ethiopian children with blood type A.

    Science.gov (United States)

    Degarege, A; Yimam, Y; Madhivanan, P; Erko, B

    2017-05-01

    The current study was conducted to evaluate the nature of association of ABO blood type with helminth infection and related reduction in haemoglobin concentration. Stool samples were collected from 403 school-age children attending Tikur Wuha Elementary School from February to April 2011. Helminth infection was examined using formol-ether concentration and thick Kato-Katz (two slides per stool specimen) techniques. Haemoglobin level was determined using a HemoCue machine and ABO blood type was determined using the antisera haemagglutination test. Nutritional status was assessed using height and weight measurements. Out of 403 children examined, 169, 120, 96 and 18 had blood type O, A, B and AB, respectively. The prevalences of helminth infections were 46.9% for hookworm, 24.6% for Schistosoma mansoni, 4.2% for Ascaris lumbricoides, 1.7% for Trichuris trichiura and 58.3% for any helminth species. The relative odds of infection with at least one helminth species was significantly higher among children with blood type A (adjusted odds ratio (AOR), 2.10; 95% confidence interval (CI), 1.28-3.45) or blood type B (AOR, 2.08; 95% CI, 1.22-3.56) as compared to children with blood type O. Among children infected with helminths, mean haemoglobin concentration was lower in those with blood type A than those with blood type O (β, -0.36; 95% CI, -0.72 to -0.01). The relative odds of hookworm infection (AOR, 1.78; 95% CI, 1.08-2.92) and related reduction in haemogobin levels (β, -0.45; 95% CI, -0.84 to -0.04) was higher among children with blood type A as compared to those with blood type O. Although the difference was not significant, the relative odds of S. mansoni or A. lumbricoides infections and related reduction in haemoglobin levels was also higher in children with blood type A or B as compared to children with blood type O. In conclusion, children with blood type A are associated with an increased risk of helminth, particularly hookworm, infection and related reduction

  4. Contínua evolução da RBC: um obrigado a todos os colaboradores!

    Directory of Open Access Journals (Sweden)

    Bruno Telles

    2017-07-01

    Full Text Available Desde de seu nascimento, a RBC prima pela divulgação do conhecimento pericial tecnicamente validado e pela discussão de novos métodos e de casos. É o caminho que há de ser constantemente trilhado pelos profissionais da perícia para que não eivem seus laudos periciais e pareceres técnicos de vícios insanáveis cujas consequências seriam nefastas para a justiça. Não é à toa que o Corpo Editorial da RBC, com o imprescindível auxílio dos editores de sessão e dos avaliadores, não envida esforços na contínua evolução da revista em direção à qualidade. Prova disso é a permanente busca por indexação em vários meios e pela elevação dos índices de qualidade por qualificação externa. A RBC aparece no Latindex, no CrossRef, no Google Scholar, no Research Gate, no Directory of Open Access Journals (DOAJ, no Electronic Journal Library (EZ3, no Scilit, no Diadorim, na ABEC Brasil, na Universitäts Bibliothek UBL Leipzig e na Qualis/CAPES.

  5. RBC-/Cr-51/ half-life and albumin turnover in growing Beagle dogs during chronic radial acceleration

    Science.gov (United States)

    Beckman, D. A.; Evans, J. W.; Oyama, J.

    1979-01-01

    The effects of chronic centrifugation on growing Beagle dogs exposed to -2 or -2.6 Gx on albumin and RBC turnover rates, albumin concentration and space, and total blood volume were determined and compared with caged and run control of animals. Albumin-(I-125) and autologous RBC-(Cr-51) preparations were injected into all dogs at day 82 of the centrifugation periods, and the disappearance curves were determined by successive bleedings of the animals over the next 35 d, during which the centrifugation was continued. There were no differences in albumin turnover rates or space. Two populations of RBCs were found in both centrifugated groups, one with a normal half-life of 27 + or - 1 S.E.M. d, and one with a significantly (p less than 0.01) shorter half-life of 15 + or - 2 S.E.M. d. An absolute polycythemia was also observed in both centrifuged groups. The results suggest that chronic centrifugation acts through some as-yet unknown mechanism to affect RBC population kinetics.

  6. Awareness and distribution of ABO, Rhesus blood groups and haemoglobin phenotypes among medical undergraduates in a Nigerian university.

    Science.gov (United States)

    Akingbola, T S; Yuguda, S; Akinyemi, O O; Olomu, S

    2016-09-01

    In the past two decades the Nigerian government and religious organisations have put more emphasis on knowing the haemoglobin electrophoresis of school children and intending couples respectively. Knowledge of the distribution of blood groups and haemoglobin electrophoretic patterns among young people is vital for the prevention of haemoglobinopathies in the population and for providing effective blood banking services. Therefore, this study was designed to assess the frequency and awareness of blood group and haemoglobinphenotypes among a new set of fourth year clinical medical and dental students of the University of Ibadan, Nigeria. Data, including socio-demographics, self- reported blood group and haemoglobin phenotypes, were obtained from 155 students using a self-administered questionnaire. The ABO, Rhesus (Rh) blood groups and haemoglobin electrophoresis were determined by the tile (slide) technique and cellulose acetate at alkaline phrespectively. Only 43.9% of the participants knew their blood groups while less than a third (29.7%) knew their haemoglobin phenotypes. knowledge of both their blood groups and haemoglobin phenotypes was documented in as low as 20.6% of the respondents. The frequency of haemoglobin AA, AS, AC and. CC were 78.0%, 16.8%, 3.9% and 1.3% respectively. Similarly, the distribution of blood groups were: 0 RhD positive - 47.8%;0 RhD negative- 1.9%;ARhD positive- 21.9%; A RhD negative - 1.3%; B RhD positive - 23.2%; B RhD negative -1.3% and AB RhD positive - 2.6%. No participant was AB RhD negative. Participants who bad previously donated blood and those who were females were more likely to know their blood groups and haemoglobin phenotypes respectively (pblood groups and haemoglobin phenotypes among the medical and dental students was poor. Documentation and routine screening for haemoglobinphenotypes as well as blood grouping, accompanied by appropriate counseling should be institutionalised in Nigeriantertiary institutions.

  7. Epidemiology of RBC Transfusions in Patients With Severe Acute Kidney Injury: Analysis From the Randomized Evaluation of Normal Versus Augmented Level Study.

    Science.gov (United States)

    Bellomo, Rinaldo; Mårtensson, Johan; Kaukonen, Kirsi-Maija; Lo, Serigne; Gallagher, Martin; Cass, Alan; Myburgh, John; Finfer, Simon

    2016-05-01

    To assess the epidemiology and outcomes associated with RBC transfusion in patients with severe acute kidney injury requiring continuous renal replacement therapy. Post hoc analysis of data from a multicenter, randomized, controlled trial. Thirty-five ICUs in Australia and New Zealand. Cohort of 1,465 patients enrolled in the Randomized Evaluation of Normal versus Augmented Level replacement therapy study. Daily information on morning hemoglobin level and amount of RBC transfused were prospectively collected in the Randomized Evaluation of Normal versus Augmented Level study. We analyzed the epidemiology of such transfusions and their association with clinical outcomes. Overall, 977 patients(66.7%) received a total of 1,192 RBC units. By day 5, 785 of 977 transfused patients (80.4%) had received at least one RBC transfusion. Hemoglobin at randomization was lower in transfused than in nontransfused patients (94 vs 111 g/L; p regression analysis, RBC transfusion was independently associated with lower 90-day mortality (hazard ratio, 0.55; 95% CI, 0.38-0.79). However, we found no independent association between RBC transfusions and mortality when the analyses were restricted to patients surviving at least 5 days (hazard ratio, 1.29; 95% CI, 0.90-1.85). We found no independent association between RBC transfusion and renal replacement therapy-free days, mechanical ventilator-free days, or length of stay in ICU or hospital. In patients with severe acute kidney injury treated with continuous renal replacement therapy, we found no association of RBC transfusion with 90-day mortality or other patient-centered outcomes. The optimal hemoglobin threshold for RBC transfusion in such patients needs to be determined in future randomized controlled trials.

  8. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  9. Reconstructing a herbivore's diet using a novel rbcL DNA mini-barcode for plants.

    Science.gov (United States)

    Erickson, David L; Reed, Elizabeth; Ramachandran, Padmini; Bourg, Norman A; McShea, William J; Ottesen, Andrea

    2017-05-01

    Next Generation Sequencing and the application of metagenomic analyses can be used to answer questions about animal diet choice and study the consequences of selective foraging by herbivores. The quantification of herbivore diet choice with respect to native versus exotic plant species is particularly relevant given concerns of invasive species establishment and their effects on ecosystems. While increased abundance of white-tailed deer ( Odocoileus virginianus ) appears to correlate with increased incidence of invasive plant species, data supporting a causal link is scarce. We used a metabarcoding approach (PCR amplicons of the plant rbc L gene) to survey the diet of white-tailed deer (fecal samples), from a forested site in Warren County, Virginia with a comprehensive plant species inventory and corresponding reference collection of plant barcode and chloroplast sequences. We sampled fecal pellet piles and extracted DNA from 12 individual deer in October 2014. These samples were compared to a reference DNA library of plant species collected within the study area. For 72 % of the amplicons, we were able to assign taxonomy at the species level, which provides for the first time-sufficient taxonomic resolution to quantify the relative frequency at which native and exotic plant species are being consumed by white-tailed deer. For each of the 12 individual deer we collected three subsamples from the same fecal sample, resulting in sequencing 36 total samples. Using Qiime, we quantified the plant DNA found in all 36 samples, and found that variance within samples was less than variance between samples ( F  = 1.73, P  = 0.004), indicating additional subsamples may not be necessary. Species level diversity ranged from 60 to 93 OTUs per individual and nearly 70 % of all plant sequences recovered were from native plant species. The number of species detected did reduce significantly (range 4-12) when we excluded species whose OTU composed plants inventoried

  10. Purification, crystallization and preliminary X-ray diffraction studies of parakeet (Psittacula krameri) haemoglobin.

    Science.gov (United States)

    Jaimohan, S M; Naresh, M D; Arumugam, V; Mandal, A B

    2009-10-01

    Birds often show efficient oxygen management in order to meet the special demands of their metabolism. However, the structural studies of avian haemoglobins (Hbs) are inadequate for complete understanding of the mechanism involved. Towards this end, purification, crystallization and preliminary X-ray diffraction studies have been carried out for parakeet Hb. Parakeet Hb was crystallized as the met form in low-salt buffered conditions after extracting haemoglobin from crude blood by microcentrifugation and purifying the sample by column chromatography. Good-quality crystals were grown from 10% PEG 3350 and a crystal diffracted to about 2.8 A resolution. Preliminary diffraction data showed that the Hb crystal belonged to the monoclinic system (space group C2), with unit-cell parameters a = 110.68, b = 64.27, c = 56.40 A, beta = 109.35 degrees . Matthews volume analysis indicated that the crystals contained a half-tetramer in the asymmetric unit.

  11. The effect of 2,3-diphosphoglycerate on the oxygen dissociation curve of human haemoglobin.

    Science.gov (United States)

    Goodford, P J; Norrington, F E; Paterson, R A; Wootton, R

    1977-01-01

    1. Oxygen dissociation curves for concentrated human haemoglobin solutions (1.6 mmol dm-3 in haem) have been measured by mixing known quantities of oxy- and deoxyhaemoglobin solutions and measuring the resulting partial pressure of oxygen with an oxygen electrode. 2. Observations in the presence of 2,3-diphosphoglycerate support previous conclusions derived from experiments at low haemoglobin concentrations, the validity of which has been questioned. 3. The two affinity state model of Monod, Wyman & Changeux (1965) does not fully describe the actions of 2,3-diphosphoglycerate and a model in which this allosteric effector not only binds preferentially to the T state but also lowers the oxygen affinity of this state gives an improved fit to the data. PMID:604451

  12. Purification, crystallization and preliminary X-ray diffraction studies of parakeet (Psittacula krameri) haemoglobin

    International Nuclear Information System (INIS)

    Jaimohan, S. M.; Naresh, M. D.; Arumugam, V.; Mandal, A. B.

    2009-01-01

    Parakeet (Psittacula krameri) haemoglobin has been purified and crystallized under low salt buffered conditions. Preliminary analysis of the crystal that belonged to monoclinic system (C2) is reported. Birds often show efficient oxygen management in order to meet the special demands of their metabolism. However, the structural studies of avian haemoglobins (Hbs) are inadequate for complete understanding of the mechanism involved. Towards this end, purification, crystallization and preliminary X-ray diffraction studies have been carried out for parakeet Hb. Parakeet Hb was crystallized as the met form in low-salt buffered conditions after extracting haemoglobin from crude blood by microcentrifugation and purifying the sample by column chromatography. Good-quality crystals were grown from 10% PEG 3350 and a crystal diffracted to about 2.8 Å resolution. Preliminary diffraction data showed that the Hb crystal belonged to the monoclinic system (space group C2), with unit-cell parameters a = 110.68, b = 64.27, c = 56.40 Å, β = 109.35°. Matthews volume analysis indicated that the crystals contained a half-tetramer in the asymmetric unit

  13. Capillary crystallization and molecular-replacement solution of haemoglobin II from the clam Lucina pectinata

    International Nuclear Information System (INIS)

    Gavira, José A.; Jesus, Walleska de; Camara-Artigas, Ana; López-Garriga, Juan; García-Ruiz, Juan M.

    2006-01-01

    The haemoglobin II from the clam L. pectinata has been crystallized using counter-diffusion in single capillary in the presence of agarose to improve crystal quality. Initial phases have been obtained by molecular replacement. Haemoglobin II is one of three haemoglobins present in the cytoplasm of the Lucina pectinata mollusc that inhabits the Caribbean coast. Using HBII purified from its natural source, crystallization screening was performed using the counter-diffusion method with capillaries of 0.2 mm inner diameter. Crystals of HbII suitable for data collection and structure determination were grown in the presence of agarose at 0.1%(w/v) in order to improve their quality. The crystals belong to the tetragonal space group P4 2 2 1 2, with unit-cell parameters a = b = 73.92, c = 152.35 Å, and diffracted X-rays to a resolution of better than 2.0 Å. The asymmetric unit is a homodimer with a corresponding Matthews coefficient (V M ) of 3.15 Å 3 Da −1 and a solvent content of 61% by volume

  14. Haemoglobin, anaemia, dementia and cognitive decline in the elderly, a systematic review

    Directory of Open Access Journals (Sweden)

    Poulter Ruth

    2008-08-01

    Full Text Available Abstract Background Anaemia may increase risk of dementia or cognitive decline. There is also evidence that high haemoglobin levels increase risk of stroke, and consequently possible cognitive impairment. The elderly are more at risk of developing dementia and are also more likely to suffer from anaemia, although there is relatively little longitudinal literature addressing this association. Methods To evaluate the evidence for any relationship between incident cognitive decline or dementia in the elderly and anaemia or haemoglobin level, we conducted a systematic review and meta-analyses of peer reviewed publications. Medline, Embase and PsychInfo were searched for English language publications between 1996 and 2006. Criteria for inclusion were longitudinal studies of subjects aged ≥65, with primary outcomes of incident dementia or cognitive decline. Other designs were excluded. Results Three papers were identified and only two were able to be combined into a meta-analysis. The pooled hazard ratio for these two studies was 1.94 (95 percent confidence intervals of 1.32–2.87 showing a significantly increased risk of incident dementia with anaemia. It was not possible to investigate the effect of higher levels of haemoglobin. Conclusion Anaemia is one factor to bear in mind when evaluating risk of incident dementia. However, there are few data available and the studies were methodologically varied so a cautionary note needs to be sounded and our primary recommendation is that further robust research be carried out.

  15. Study of helminthiasis in pregnancy and its correlation with haemoglobin level.

    Science.gov (United States)

    K, Shrinivas; Radhika; R, Sreelatha; K, Kavitha

    2014-10-01

    To study types of worm infestation in pregnancy and to correlate helminthiasis with haemoglobin level in antenatal women presenting in 2nd and 3rd trimester. This prospective cross sectional hospital based study conducted at Vanivilas hospital attached to Bangalore medical college, over a period of sixmonths. Study included 500 pregnant women attending antenatal opd in 2nd and 3rd trimester, selected by systematic random sampling method. Parasitic examination and haemoglobin estimation done respectively with Stool and blood samples collected from study group. Presence of parasites was correlated with haemoglobin percentage. Helminthiasis was found in 62 women (12.4%). All infected women had single type helminth infection. Ascariasis was more commonly found than hookworm (10% Vs 2.4%). Anaemia of various degrees was found in 88.7% of women with helminthiasis as compared to 56.4% women without worm infestation (p-value Helminthiasis is a significant burden in pregnancy and it is associated with anaemia. Hence, the policy of universal administration of anthelminthic drug in pregnancy after first trimester, as recommended by WHO should be practically enforced besides health education.

  16. Effect of Vitamin C and Tablets Fe on Haemoglobin Levels Against Pregnant Women

    Directory of Open Access Journals (Sweden)

    Susilo Wirawan

    2016-01-01

    Full Text Available Background: Iron deficiency anaemia is the most common nutritional problem of pregnant women in Indonesia. The existing program/intervention has been implemented namely supplementation of iron pills for mothers at the third semester of pregnancy. This study aims to compare the effect of single and multiple micronutrients supplementation of iron and iron plus vitamin C. Methods: Type of the study is study experimental with the design of community intervention, implementing pre and post trials. Subjects were pregnant women at the second semester of pregnancy. Haemoglobin level was examinedby Cyanmet hemoglobin. Data analysis was done through independent and paired t-test. Results: showed that there were statistically signifi cant difference between the intervention and control group (p = 0.001. The haemoglobin level of the intervention group increased by 0.91 grm%, while the control group was 0.43 grm%. The proportion of anaemia amongpregnant mothers declined after intervention from 80.95 to 42.86 at the intervention group. Similarly, the proportion of anaemia of the control group reduced from 80.95% to 71.43% after the intervention. Conclusion: intervention with multiple micronutrients of Fe combined with vitamin C has more effect in changing the haemoglobin levels of pregnant mothers.Recommendation: Fe tablet administration should still be accompanied by vitamin C to help boost hemoglobin levels. Required for controlled administration of iron tablet, along with vitamin C so that the effect can be seen.

  17. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  18. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  19. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  20. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  1. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  2. Evaluation of haemoglobin (erythrogen): for improved somatic embryogenesis and plant regeneration in cotton (Gossypium hirsutum L. cv. SVPR 2).

    Science.gov (United States)

    Ganesan, M; Jayabalan, N

    2004-10-01

    Somatic embryogenesis in cotton (Gossypium hirsutum L.) is accelerated when the plant regeneration medium is supplemented with haemoglobin (erythrogen). In cotton SVPR 2 lines, a higher frequency of embryoid formation was observed when the medium contained 400 mg/l haemoglobin. Fresh weight of the callus, rate of embryoid induction, number of embryoids formed and the percentage of plant regeneration from somatic embryos were increased. Among the two different cultivars tested, MCU 11 showed no response to the presence of haemoglobin when compared to SVPR 2, and embryogenic callus formation was completely absent in the former. Medium containing MS salts, 100 mg/l myo-inositol , 0.3 mg/l thiamine-HCL, 0.3 mg/l Picloram (PIC), 0.1 mg/l kinetin and 400 mg/l haemoglobin effected a better response with respect to embryogenic callus induction. After 8 weeks of culture, a high frequency of embryoid induction was observed on medium containing MS basal salts, 100 mg/l myo-inositol, 0.3 mg/l PIC , 0.1 mg/l isopentenyl adenine, 1.0 g/l NH4NO3 and 400 mg/l haemoglobin. Plant regeneration was observed in 75.8% of the mature somatic embryos, and whole plant regeneration was achieved within 6-7 months of culture. The regenerated plantlets were fertile and similar to in vivo-grown, seed-derived plants except that they were phenotypically smaller. A positive influence of haemoglobin was observed at concentrations up to 400 mg/l at all stages of somatic embryogenesis. The increase in the levels of antioxidant enzyme activities, for example superoxide dismutase and peroxidase, indicated the presence of excess oxygen uptake and the stressed condition of the plant tissues that arose from haemoglobin supplementation. This increased oxygen uptake and haemoglobin-mediated stress appeared to accelerate somatic embryogenesis in cotton.

  3. The predictive value of current haemoglobin levels for incident tuberculosis and/or mortality during long-term antiretroviral therapy in South Africa: a cohort study.

    Science.gov (United States)

    Kerkhoff, Andrew D; Wood, Robin; Cobelens, Frank G; Gupta-Wright, Ankur; Bekker, Linda-Gail; Lawn, Stephen D

    2015-04-02

    Low haemoglobin concentrations may be predictive of incident tuberculosis (TB) and death in HIV-infected patients receiving antiretroviral therapy (ART), but data are limited and inconsistent. We examined these relationships retrospectively in a long-term South African ART cohort with multiple time-updated haemoglobin measurements. Prospectively collected clinical data on patients receiving ART for up to 8 years in a community-based cohort were analysed. Time-updated haemoglobin concentrations, CD4 counts and HIV viral loads were recorded, and TB diagnoses and deaths from all causes were ascertained. Anaemia severity was classified using World Health Organization criteria. TB incidence and mortality rates were calculated and Poisson regression models were used to identify independent predictors of incident TB and mortality, respectively. During a median follow-up of 5.0 years (IQR, 2.5-5.8) of 1,521 patients, 476 cases of incident TB and 192 deaths occurred during 6,459 person-years (PYs) of follow-up. TB incidence rates were strongly associated with time-updated anaemia severity; those without anaemia had a rate of 4.4 (95%CI, 3.8-5.1) cases/100 PYs compared to 10.0 (95%CI, 8.3-12.1), 26.6 (95%CI, 22.5-31.7) and 87.8 (95%CI, 57.0-138.2) cases/100 PYs in those with mild, moderate and severe anaemia, respectively. Similarly, mortality rates in those with no anaemia or mild, moderate and severe time-updated anaemia were 1.1 (95%CI, 0.8-1.5), 3.5 (95%CI, 2.7-4.8), 11.8 (95%CI, 9.5-14.8) and 28.2 (95%CI, 16.5-51.5) cases/100 PYs, respectively. Moderate and severe anaemia (time-updated) during ART were the strongest independent predictors for incident TB (adjusted IRR = 3.8 [95%CI, 3.0-4.8] and 8.2 [95%CI, 5.3-12.7], respectively) and for mortality (adjusted IRR = 6.0 [95%CI, 3.9-9.2] and adjusted IRR = 8.0 [95%CI, 3.9-16.4], respectively). Increasing severity of anaemia was associated with exceptionally high rates of both incident TB and mortality during

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  15. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  19. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  1. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  3. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  4. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  5. Arabidopsis Pol II-Dependent in Vitro Transcription System Reveals Role of Chromatin for Light-Inducible rbcS Gene Transcription1

    Science.gov (United States)

    Ido, Ayaka; Iwata, Shinya; Iwata, Yuka; Igarashi, Hisako; Hamada, Takahiro; Sonobe, Seiji; Sugiura, Masahiro; Yukawa, Yasushi

    2016-01-01

    In vitro transcription is an essential tool to study the molecular mechanisms of transcription. For over a decade, we have developed an in vitro transcription system from tobacco (Nicotiana tabacum)-cultured cells (BY-2), and this system supported the basic activities of the three RNA polymerases (Pol I, Pol II, and Pol III). However, it was not suitable to study photosynthetic genes, because BY-2 cells have lost their photosynthetic activity. Therefore, Arabidopsis (Arabidopsis thaliana) in vitro transcription systems were developed from green and etiolated suspension cells. Sufficient in vitro Pol II activity was detected after the minor modification of the nuclear soluble extracts preparation method; removal of vacuoles from protoplasts and L-ascorbic acid supplementation in the extraction buffer were particularly effective. Surprisingly, all four Arabidopsis Rubisco small subunit (rbcS-1A, rbcS-1B, rbcS-2B, and rbcS-3B) gene members were in vitro transcribed from the naked DNA templates without any light-dependent manner. However, clear light-inducible transcriptions were observed using chromatin template of rbcS-1A gene, which was prepared with a human nucleosome assembly protein 1 (hNAP1) and HeLa histones. This suggested that a key determinant of light-dependency through the rbcS gene transcription was a higher order of DNA structure (i.e. chromatin). PMID:26662274

  6. 浮萍中一个新rbcS基因启动子的克隆及分析%Analysis of a Novel rbcS Promoter Cloned in Duckweed

    Institute of Scientific and Technical Information of China (English)

    王友如

    2010-01-01

    为了分离组织特异性、诱导性的启动子,本研究根据新克隆的浮萍rbcS基因序列设计引物,采用改进的5'walking技术从浮萍基因组中克隆了一个新的rbcS基因启动子,命名为SSU5C基因启动子.序列分析表明:SSU5C基因启动子长度为1 543 bp,含有保守性元件TATA和CAAT box,并且含有水杨酸、脱落酸、赤霉素、茉莉酸甲酯等植物激素和葡萄糖等的保守顺式作用元件.In silico分析初步推测SSU5C基因启动子受多种信号途径的协调调控.

  7. Changes in haemoglobin levels according to changes in body mass index and smoking habits, a 20-year follow-up of a male cohort

    International Nuclear Information System (INIS)

    Skjelbakken, Tove; Dahl, Inger Marie S.; Wilsgaard, Tom; Langbakk, Bodil; Lochen, Maja-Lisa

    2006-01-01

    Haemoglobin level declines with increasing age in cross sectional studies. Little is known about the longitudinal changes of haemoglobin. Because both high or low haemoglobin levels increase mortality and morbidity we examined how changes in lifestyle factors like body mass index (BMI) and smoking habits influence cohort changes in haemoglobin level. In all, 4159 men aged 20-49 years at baseline were examined in 1974 and 1994-1995 in a longitudinal, population-based study from the municipality of Tromso, Northern Norway. Mean haemoglobin was 148 g/l. There was no difference in mean haemoglobin after 20 years in any strata of age. Mean BMI increased 2.1 kg/m 2 . The prevalence of smokers decreased 20.1 percentage points. In a multiple regression analysis increase in BMI was associated with increased haemoglobin change. Smoking cessation lowered mean haemoglobin 1.6 g/l compared to never smokers. Haemoglobin increased 0.8 g/l in smoking quitters whose BMI increased >2.5 kg/m 2 compared to a decrease of 6.7 g/l in weight reducers. There was a positive dose-response relationship between changes in cigarettes smoked per day and change in haemoglobin among consistent smokers. In conclusion, in contrast to cross sectional studies, mean haemoglobin did not change during 20 years ageing of relatively young men. This could be explained by higher BMI and less smoking. The increase in BMI affected haemoglobin change to such an extent that the reduction in haemoglobin due to smoking cessation was counteracted. Prospective studies are needed to address the health implications

  8. Maternal anaemia at delivery and haemoglobin evolution in children during their first 18 months of life using latent class analysis.

    Directory of Open Access Journals (Sweden)

    Kobto G Koura

    Full Text Available BACKGROUND: Anaemia during pregnancy and at delivery is an important public health problem in low- and middle-income countries. Its association with the children's haemoglobin level over time remains unclear. Our goals were to identify distinct haemoglobin level trajectories using latent class analysis and to assess the association between these trajectories and maternal anaemia and other risk factors. METHOD: A prospective study of children from birth to 18 months of life was conducted in a rural setting in Tori-Bossito, Benin. The main outcome measure was the haemoglobin levels repeatedly measured at 3, 6, 9, 12, 15 and 18 months. Variables were collected from the mothers at delivery and from their children at birth and during the follow-up. The analyses were performed by means of Latent Class Analysis which has never been used for this kind of data. All the analyses were performed with Stata software, version 11.0, using the generalized linear latent and mixed model (GLLAMM framework. RESULTS: We showed that 33.7% of children followed a low haemoglobin trajectory and 66.3% a high trajectory during the first 18 months of life. Newborn anaemia, placental malaria, malaria attack, sickle cell trait and male gender were significantly associated with a lower children's haemoglobin level over time, whereas maternal age, children living in a polygamous family and with good feeding practices had a higher Hb level in the first18 months. We also showed that maternal anaemia was a predictor for 'low haemoglobin level trajectory' group membership but have no significant effect on children haemoglobin level over time. CONCLUSION: Latent Class Analyses framework seems well suited to analyse longitudinal data under the hypothesis that different subpopulations of subjects are present in the data, each with its own set of parameters, with distinctive evolutions that themselves may reflect distinctive aetiologies.

  9. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    Science.gov (United States)

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Oral supplementation of vitamin E reduces osmotic fragility of RBC in hemolytic anemic patients with G6PD deficiency

    International Nuclear Information System (INIS)

    Sultana, N.; Begum, S.; Begum, N.; Ali, T.

    2009-01-01

    Vitamin E has role in maintaining the integrity of red cell member by preventing oxidation of polyunsaturated fatty acids, thus protects cells from oxidative stress-induced lysis in G6PD deficiency. Changes in osmotic fragility of RBC and some absolute values like MCV, MCH and MCHC may occur in haemolytic anaemic patients with G6PD deficiency. To observe the effects of vitamin E supplementation on these changes in order to evaluate the role of this anti-oxidant vitamin in reducing chronic haemolysis in G6PD deficient patients. A total number of 102 subjects with age ranged of 5 to 40 years of both sexes were included in the study. Among them 68 were G6PD enzyme deficient patients, of whom 34 were in supplemented group (experimental group) and 34 were in non-supplemented group (control group). The supplemented group received vitamin E supplementation for 60 consecutive days at a dose of 800 IU/day for adult and 400 IU/day for children ?12 years (in a divided dose, i.e., 4 times daily). Age and sex matched 34 apparently healthy subjects with normal blood G6PD level were taken to observe the base line data (healthy control) and also for comparison. All the G6PD deficient patients were selected from Out Patient Department (OPD) of Haematology, Banglabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh from July 2005 to June 2006 and all healthy subjects were selected from personal contact. Blood G6PD level, osmotic fragility of RBC were measured by standard techniques and MCV, MCH, and MCHC were obtained by calculation. All the parameters were measured on day 1 of their first visit and also were on day 60 in deficient group. Data were compared among the deficient groups, also in supplemented group just before and after supplementation. Analysis of data was done by appropriate statistical method. Mean starting and completing points of osmotic fragility of RBC were significantly higher but MCV. MCH, MCHC were significantly lower in patients suffering from

  11. Soluble haemoglobin is a marker of recent Plasmodium falciparum infections

    DEFF Research Database (Denmark)

    Jakobsen, P H; Bygbjerg, I C; Theander, T G

    1997-01-01

    Monoclonal antibodies (Mab) were raised against haemoglobin (Hb) associated with Plasmodium falciparum protein and used to develop an ELISA, measuring circulating levels of released Hb. This assay was evaluated in different malaria patients in parallel with ELISA assays for C-reactive protein (CR...... after treatment. Soluble Hb levels were associated with malariometric parameters in a similar fashion to haptoglobin. The new Mab-based assay for measuring soluble Hb in the peripheral blood of malaria patients may be useful for future epidemiological studies of malaria....

  12. Epidemiological evidence for the role of the haemoglobin receptor, HmbR, in meningococcal virulence

    OpenAIRE

    Harrison, Odile B.; Evans, Nicholas J.; Blair, Jessica M.; Grimes, Holly S.; Tinsley, Colin R.; Nassif, Xavier; Kriz, Paula; Ure, Roisin; Gray, Steve J.; Derrick, Jeremy P.; Maiden, Martin C.J.; Feavers, Ian M.

    2009-01-01

    The distribution of the haemoglobin receptor gene (hmbR) was investigated in disease and carried Neisseria meningitidis isolates revealing that the gene occurred at a significantly higher frequency in disease isolates compared to those obtained from carriage. Where hmbR was absent, the locus was occupied by the cassettes exl2 or exl3, or with a “pseudo hmbR” gene designated exl4. The hmbR locus in published N. meningitidis genomes, as well as N. gonorrhoeae and N. lactamica ST-640, exhibited ...

  13. Selection of GP. Mur antigen-negative RBC for blood recipients with anti-'Mia ' records decreases transfusion reaction rates in Taiwan.

    Science.gov (United States)

    Yang, C-A; Lin, J-A; Chang, C-W; Wu, K-H; Yeh, S-P; Ho, C-M; Chang, J-G

    2016-10-01

    To evaluate the clinical significance of GP. Mur antigen-negative blood selection for transfusion in patients with anti-'Mi a ' records. The GP. Mur RBC phenotype is prevalent (7·3%) in Taiwan. Antibodies against GP. Mur (anti-'Mi a ') are identified in 1·24% of our population, and anti-'Mi a ' screening using GP. Mur RBC has been routine for Taiwan's blood banks. However, due to the lack of commercial antibodies, only cross-matching was used to prevent transfusion of GP. Mur-positive blood to patients with anti-'Mi a ' in most hospitals. There is still a risk of GP. Mur-positive RBC exposure and subsequent anti-'Mi a '-related transfusion reactions. Since February 2014, GP. Mur antigen-negative RBCs identified by reaction with anti-'Mi a '-positive serum were selected for blood recipients with anti-'Mi a ' records. The transfusion reactions between January 2013 and January 2014 were compared with those that occurred between February 2014 and July 2015. The transfusion reaction rate was significantly higher in anti-'Mi a '-positive blood recipients compared to total subjects receiving an RBC transfusion before GP. Mur-negative donor RBC selection. After antigen-negative RBC selection, the transfusion reaction frequency in subjects with anti-'Mi a ' became similar to total blood recipients. IgG form anti-'Mi a ' antibodies were present in all cases of probable anti-'Mi a '-related transfusion reactions. The time required for anti-'Mi a ' boosting after transfusion was around 4-21 days. Selection of GP. Mur-negative RBC for transfusion to patients with anti-'Mi a ' records could decrease the rate of transfusion reaction and antibody boosting. This procedure should be incorporated into blood bank routines in areas where anti-'Mi a ' is prevalent. © 2016 British Blood Transfusion Society.

  14. Reflexiones sobre la estrategia de rehabilitación basada en la comunidad (RBC: la experiencia de un programa de RBC en Bolivia Reflections on community-based rehabilitation strategy (CBR: the experience of a CBR program in Bolivia

    Directory of Open Access Journals (Sweden)

    Urko Díaz-Aristizabal

    2012-01-01

    Full Text Available La Rehabilitación Basada en la Comunidad (RBC es una estrategia de desarrollo comunitario avalada por la Organización Mundial de la Salud (OMS, la Organización Internacional del Trabajo (OIT y la Organización de las Naciones Unidas para la Educación, la Ciencia y la Cultura (UNESCO, que persigue la rehabilitación, la igualdad de oportunidades y la integración social de las Personas con Discapacidad (PD en sus entornos. Con este objetivo promueve la colaboración entre las PD, sus familias y los diferentes actores de la comunidad involucrados, así como el liderazgo comunitario y la participación de las PD mediante el impulso de la colaboración multisectorial. Este artículo expone los antecedentes históricos y las características fundamentales de la estrategia de RBC a partir de un programa llevado a cabo por una fundación del departamento de Cochabamba (Bolivia, para después incidir en algunos aspectos referentes al contexto sociocultural, que especialmente en situaciones de interculturalidad, pueden determinar que un programa de RBC tenga éxito o esté abocado al fracaso.Community-Based Rehabilitation (CBR is a strategy for community development endorsed by the World Health Organization (WHO, the International Labor Office (ILO and the United Nations Educational, Scientific and Cultural Organization (UNESCO. It is designed to promote rehabilitation, equal opportunity and social inclusion of Disabled Persons (DP in their home communities by fostering cooperation among disabled individuals, their families, and other concerned social actors, it encourages community leadership and full social participation by DP through multi-sector cooperation. This article explores the historical antecedents and basic features of CBR strategy through an analysis of a directed culture change initiative developed by a foundation in the Cochabamba administrative region of Bolivia. Especially in intercultural environments, certain aspects of the socio

  15. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  16. New technology increases perioperative haemoglobin levels for paediatric cardiopulmonary bypass: what is the benefit?

    Science.gov (United States)

    Thuys, Clarke; Horton, Stephen; Bennett, Martin; Augustin, Simon

    2006-01-01

    Increasing perioperative haemoglobin level by reducing priming volume and maintaining a safe cardiopulmonary bypass (CPB) system is the aim of every perfusionist. In this study, we have compared the two membrane oxygenators and pump systems used for paediatric bypass at the Royal Children's Hospital on a regular basis since 1988. We looked at all patients who had the Cobe VPCML (Cobe Laboratories, Denver, CO, USA) and Terumo RX-05 (Terumo Corporation, Tokyo, Japan) oxygenators used for flows from 800 mL/min up to the maximum rated flow for the respective oxygenator from January 2002 until March 2004. The VPCML refers to using only the 0.4-m2 section of the oxygenator. The pump systems used were the Stöckert CAPS (Stöckert Instrumente GmbH, Munich, Germany) and Jostra HL 30 (Jostra AB, Lund, Sweden). Changing from the VPCML to the RX-05 resulted in a 37% reduction in priming volume. The introduction of the Jostra HL 30 with a custom-designed mast system reduced the priming volume by another 15%. This change in priming volume allowed a significant increase, from 6 to 34%, in the percentage of patients who received bloodless primes, and for those patients who received blood primes, an increase in haemoglobin (Hb) on bypass from 8.2 to 9.6 g/dL, on average.

  17. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  18. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. Analysis of RBC-microparticles in stored whole blood bags - a promising marker to detect blood doping in sports?

    Science.gov (United States)

    Voss, Sven Christian; Jaganjac, Morana; Al-Thani, Amna Mohamed; Grivel, Jean-Charles; Raynaud, Christophe Michel; Al-Jaber, Hind; Al-Menhali, Afnan Saleh; Merenkov, Zeyed Ahmad; Alsayrafi, Mohammed; Latiff, Aishah; Georgakopoulos, Costas

    2017-11-01

    Blood doping in sports is prohibited by the World Anti-Doping Agency (WADA). To find a possible biomarker for the detection of blood doping, we investigated the changes in blood stored in CPDA-1 blood bags of eight healthy subjects who donated one unit of blood. Aliquots were taken on days 0, 14, and 35. Platelet-free plasma was prepared and stored at -80°C until analysis on a flow cytometer dedicated for the analysis of microparticles (MPs). Changes in the number of red blood cell (RBC) -MPs were highly significant (p doping control but confirmation by a transfusion study is necessary. Copyright © 2017 John Wiley & Sons, Ltd.

  20. The effect of golimumab on haemoglobin levels in patients with rheumatoid arthritis, psoriatic arthritis or ankylosing spondylitis.

    Science.gov (United States)

    Furst, Daniel E; Kay, Jonathan; Wasko, Mary Chester; Keystone, Edward; Kavanaugh, Arthur; Deodhar, Atul; Murphy, Frederick T; Magnus, Jeanette H; Hsia, Elizabeth C; Hsu, Benjamin; Xu, Stephen; Rahman, Mahboob U; Doyle, Mittie K

    2013-10-01

    To evaluate the effect of golimumab on haemoglobin levels in patients with RA, PsA or AS. Secondary analysis was performed on integrated data from five randomized controlled studies: three RA, one PsA and one AS (2303 patients total). Golimumab 50 or 100 mg was injected s.c. every 4 weeks with or without MTX. Control groups received placebo injections plus MTX or background therapy. Patients with haemoglobin levels below the age- and sex-specific normal ranges were considered to have anaemia. Ferritin levels were used to distinguish anaemia of mixed aetiology (≥ 15 and <60 ng/ml) and anaemia of inflammation (≥ 60 ng/ml). Changes from baseline to weeks 14 and 24 in haemoglobin level were compared between treatment groups using an analysis of variance on the van der Waerden normal scores. At baseline, 21% of RA patients, 9% of PsA patients and 15% of AS patients had anaemia. Of these, 24%, 57% and 25%, respectively, had anaemia of inflammation. The median increase from baseline to week 14 in the haemoglobin level of anaemic patients was 0.3 g/dl in the control group and 0.9 g/dl in the golimumab group (P < 0.001). Haemoglobin levels improved within the subgroups of patients with anaemia of mixed aetiology (control, 0.4 g/dl vs golimumab, 0.7 g/dl) (P = 0.305) and with anaemia of inflammation (0.2 vs 1.4 g/dl, respectively) (P < 0.001). Compared with the control group, patients receiving golimumab treatment had significantly improved haemoglobin levels, particularly among patients with anaemia of inflammation.

  1. Modal Logics with Counting

    Science.gov (United States)

    Areces, Carlos; Hoffmann, Guillaume; Denis, Alexandre

    We present a modal language that includes explicit operators to count the number of elements that a model might include in the extension of a formula, and we discuss how this logic has been previously investigated under different guises. We show that the language is related to graded modalities and to hybrid logics. We illustrate a possible application of the language to the treatment of plural objects and queries in natural language. We investigate the expressive power of this logic via bisimulations, discuss the complexity of its satisfiability problem, define a new reasoning task that retrieves the cardinality bound of the extension of a given input formula, and provide an algorithm to solve it.

  2. Digital coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.; Ius, D.

    1996-01-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method. (orig.)

  3. Digital coincidence counting

    Science.gov (United States)

    Buckman, S. M.; Ius, D.

    1996-02-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.

  4. Comparative genome-wide analysis and evolutionary history of haemoglobin-processing and haem detoxification enzymes in malarial parasites.

    Science.gov (United States)

    Ponsuwanna, Patrath; Kochakarn, Theerarat; Bunditvorapoom, Duangkamon; Kümpornsin, Krittikorn; Otto, Thomas D; Ridenour, Chase; Chotivanich, Kesinee; Wilairat, Prapon; White, Nicholas J; Miotto, Olivo; Chookajorn, Thanat

    2016-01-29

    Malaria parasites have evolved a series of intricate mechanisms to survive and propagate within host red blood cells. Intra-erythrocytic parasitism requires these organisms to digest haemoglobin and detoxify iron-bound haem. These tasks are executed by haemoglobin-specific proteases and haem biocrystallization factors that are components of a large multi-subunit complex. Since haemoglobin processing machineries are functionally and genetically linked to the modes of action and resistance mechanisms of several anti-malarial drugs, an understanding of their evolutionary history is important for drug development and drug resistance prevention. Maximum likelihood trees of genetic repertoires encoding haemoglobin processing machineries within Plasmodium species, and with the representatives of Apicomplexan species with various host tropisms, were created. Genetic variants were mapped onto existing three-dimensional structures. Genome-wide single nucleotide polymorphism data were used to analyse the selective pressure and the effect of these mutations at the structural level. Recent expansions in the falcipain and plasmepsin repertoires are unique to human malaria parasites especially in the Plasmodium falciparum and P. reichenowi lineage. Expansion of haemoglobin-specific plasmepsins occurred after the separation event of Plasmodium species, but the other members of the plasmepsin family were evolutionarily conserved with one copy for each sub-group in every Apicomplexan species. Haemoglobin-specific falcipains are separated from invasion-related falcipain, and their expansions within one specific locus arose independently in both P. falciparum and P. vivax lineages. Gene conversion between P. falciparum falcipain 2A and 2B was observed in artemisinin-resistant strains. Comparison between the numbers of non-synonymous and synonymous mutations suggests a strong selective pressure at falcipain and plasmepsin genes. The locations of amino acid changes from non

  5. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy.

    Science.gov (United States)

    Zink, Stephen I; Ohki, Stephen K; Stein, Barry; Zambuto, Domenic A; Rosenberg, Ronald J; Choi, Jenny J; Tubbs, Daniel S

    2008-10-01

    The purpose of our study was to compare contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning for the evaluation of active lower gastrointestinal bleeding. Over 17 months, 55 patients (32 men, 23 women; age range, 21-92 years) were evaluated prospectively with contrast-enhanced MDCT using 100 mL of iopromide 300 mg I/mL. Technetium-99m-labeled RBC scans were obtained on 41 of 55 patients and select patients underwent angiography for attempted embolization. Each imaging technique was reviewed in a blinded fashion for sensitivity for detection of active bleeding as well as the active lower gastrointestinal bleeding location. Findings were positive on both examinations in eight patients and negative on both examinations in 20 patients. Findings were positive on contrast-enhanced MDCT and negative on (99m)Tc-labeled RBC in two patients; findings were negative on contrast-enhanced MDCT and positive on (99m)Tc-labeled RBC in 11 patients. Statistics showed significant disagreement, with simple agreement = 68.3%, kappa = 0.341, and p = 0.014. Sixteen of 60 (26.7%) contrast-enhanced MDCT scans were positive prospectively, with all accurately localizing the site of bleeding and identification of the underlying lesion in eight of 16 (50%). Nineteen of 41 (46.3%) (99m)Tc-labeled RBC scans were positive. Eighteen of 41 matched patients went on to angiography. In four of these 18 (22.2%) patients, the site of bleeding was confirmed by angiography, but in 14 of 18 (77.8%), the findings were negative. Contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning show significant disagreement for evaluation of active lower gastrointestinal bleeding. Contrast-enhanced MDCT appears effective for detection and localization in cases of active lower gastrointestinal bleeding in which hemorrhage is active at the time of CT.

  6. RBC acetyl cholinesterase: A poor man′s early diagnostic biomarker for familial alzheimer′s and Parkinson′s disease dementia

    Directory of Open Access Journals (Sweden)

    Himmatrao Saluba Bawaskar

    2015-01-01

    Full Text Available Objective: Analysis of red blood cell acetyl cholinesterase (AChE in a familial Alzheimer′s diseases (AD Parkinson′s disease dementia (PDD and their first generation. Setting: General hospital, Mahad district, Raigad. Patients and Methods: Clinically diagnosed patients of AD and PDD and their asymptomatic relatives. Their blood was collected in EDTA tube and transferred to laboratory at Mumbai. Result: Median red blood cell (RBC cholinesterase levels amongst PDD, their first generation asymptomatic relatives, familial AD, asymptomatic relatives of AD, healthy controls, farmers exposed to pesticides (positive control and other neurological condition without dementia (hypertension with TIA 1, sub-dural hematoma 2, hypothyroid 1, non-familial unilateral parkinsonism without dementia 3, writers cramps 2, hyponitremia 1 and cerebral palsy with non-fluent aphasia 1. Median values of RBC AChE were 19086.78 U/L, 15666.05 U/L, 9013.11 U/L, 7806.19 U/L, 14334.57 U/L, 9785.05 U/L and 13162.60 U/L, respectively. As compared to controls, RBC AChE levels were statistically significant among PDD (P = 0.004 and significantly lowered among familial AD patients (P = 0.010, relatives of patients (P = 0.010. Interpretations: Below the normal RBC AChE level is a potential biomarker in asymptomatic relatives of familial AD patients. RBC AChE is raised than normal level in patients suffering from PDD, where AChE inhibitors are helpful. However, RBC AChE level below the normal where AChE inhibitor may not be effective.

  7. A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Lim, Seok Tae; Kim, Dong Wook; Yim, Chang Yeol [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

  8. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  9. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Torricelli, Alessandro; Quaresima, Valentina; Pifferi, Antonio; Biscotti, Giovanni; Spinelli, Lorenzo; Taroni, Paola; Ferrari, Marco; Cubeddu, Rinaldo

    2004-01-01

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO 2 ) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO 2 was 73.0 ± 0.9 and 70.5 ± 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO 2 decreased (69.1 ± 1.8 and 63.8 ± 2.1% in MG and LG, respectively; P 2 and tHb

  10. Haemoglobin Pierre-Benite--a high affinity variant associated with relative polycythaemia.

    Science.gov (United States)

    Beard, M E; Potter, H C; Spearing, R L; Brennan, S O

    2001-12-01

    This is the second reported example of Hb Pierre--Benite (beta90 Glu-->Asp). This mutation is associated with increased oxygen affinity and polycythaemia. No instability was found and there was no charge shift detected by cellulose acetate electrophoresis at pH 8.3. The mutation was however, clearly indicated by electrospray ionization mass spectrometry (ESI MS), which showed an abnormal beta chain with a 14 Da decrease in mass. Blood volume studies documented a relative rather than a true polycythaemia and this finding has been reported in at least two other high affinity haemoglobin variants--Hb Heathrow and Hb Rahere. This finding led to delay in diagnosis because high oxygen affinity variants are conventionally considered to cause a true polycythaemia.

  11. Haemoglobin modulates NO emission and hyponasty under hypoxia-related stress in Arabidopsis thaliana

    DEFF Research Database (Denmark)

    Hebelstrup, Kim; van Zanten, Martijn; Mandon, Julien

    2012-01-01

    Nitric oxide (NO) and ethylene are signalling molecules that are synthesized in response to oxygen depletion. Non-symbiotic plant haemoglobins (Hbs) have been demonstrated to act in roots under oxygen depletion to scavenge NO. Using Arabidopsis thaliana plants, the online emission of NO or ethylene...... was directly quantified under normoxia, hypoxia (0.1–1.0% O2), or full anoxia. The production of both gases was increased with reduced expression of either of the Hb genes GLB1 or GLB2, whereas NO emission decreased in plants overexpressing these genes. NO emission in plants with reduced Hb gene expression......-nitrosylated compounds, and it is demonstrated that hypoxia substantially increased the content of S-nitrosylated compounds. A parallel up-regulation of Hb gene expression in the normoxic shoots of the flooded plants may reflect signal transmission from root to shoot via ethylene and a role for Hb in the shoots. Hb gene...

  12. [Role of erythrocyte cytoplasmic structures in changes in the affinity of haemoglobin for oxygen].

    Science.gov (United States)

    Bryzgalova, N Iu; Brazhe, N A; Iusipovich, A U; Maksimov, G V; Rubin, A B

    2009-01-01

    Changes in the refractive index of the cytoplasm and the affinity of haemoporphyrin of erythrocyte haemoglobin to oxygen (pH, 2,3-diphosphoglycerate) have been investigated using laser interference microscopy and Raman spectroscopy. It has been established that a decrease in pH and an increase in the content of 2,3-diphosphoglycerate are accompanied by changes in both the form of the cell and the refractive index of the cytoplasm and the affinity of haemoporphyrin of hemoglobin to oxygen. It has been shown that as pH is reduced, the capacity of haemoporphyrin for binding oxygen decreases and as the concentration of 2,3-diphosphoglycerate is increased, the ability of haemoporphyrin for oxygen reabsorption increases.

  13. Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.

    Science.gov (United States)

    Gough, Clare E; Saunders, Philo U; Fowlie, John; Savage, Bernard; Pyne, David B; Anson, Judith M; Wachsmuth, Nadine; Prommer, Nicole; Gore, Christopher J

    2012-09-01

    We compared changes in performance and total haemoglobin mass (tHb) of elite swimmers in the weeks following either Classic or Live High:Train Low (LHTL) altitude training. Twenty-six elite swimmers (15 male, 11 female, 21.4 ± 2.7 years; mean ± SD) were divided into two groups for 3 weeks of either Classic or LHTL altitude training. Swimming performances over 100 or 200 m were assessed before altitude, then 1, 7, 14 and 28 days after returning to sea-level. Total haemoglobin mass was measured twice before altitude, then 1 and 14 days after return to sea-level. Changes in swimming performance in the first week after Classic and LHTL were compared against those of Race Control (n = 11), a group of elite swimmers who did not complete altitude training. In addition, a season-long comparison of swimming performance between altitude and non-altitude groups was undertaken to compare the progression of performances over the course of a competitive season. Regardless of altitude training modality, swimming performances were substantially slower 1 day (Classic 1.4 ± 1.3% and LHTL 1.6 ± 1.6%; mean ± 90% confidence limits) and 7 days (0.9 ± 1.0% and 1.9 ± 1.1%) after altitude compared to Race Control. In both groups, performances 14 and 28 days after altitude were not different from pre-altitude. The season-long comparison indicated that no clear advantage was obtained by swimmers who completed altitude training. Both Classic and LHTL elicited ~4% increases in tHb. Although altitude training induced erythropoeisis, this physiological adaptation did not transfer directly into improved competitive performance in elite swimmers.

  14. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.

    Science.gov (United States)

    Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  15. Relationship between haemoglobin concentration and packed cell volume in cattle blood samples

    Directory of Open Access Journals (Sweden)

    Paa-Kobina Turkson

    2015-02-01

    Full Text Available A convention that has been adopted in medicine is to estimate haemoglobin (HB concentration as a third of packed cell volume (PCV or vice versa. The present research set out to determine whether a proportional relationship exists between PCV and Hb concentration in cattle blood samples, and to assess the validity of the convention of estimating Hb concentration as a third of PCV. A total of 440 cattle in Ghana from four breeds (Ndama, 110; West African Short Horn, 110; Zebu, 110 and Sanga, 110 were bled for haematological analysis, specifically packed cell volume, using the microhaematocrit technique and haemoglobin concentration using the cyanmethaemoglobin method. Means, standard deviations, standard errors of mean and 95% confidence intervals were calculated. Trendline analyses generated linear regression equations from scatterplots. For all the cattle, a significant and consistent relationship (r = 0.74 was found between Hb concentration and PCV (%. This was expressed as Hb concentration (g/dL = 0.28 PCV + 3.11. When the Hb concentration was estimated by calculating it as a third of PCV, the relationship was expressed in linear regression as Hb concentration (g/dL = 0.83 calculated Hb + 3.11. The difference in the means of determined (12.2 g/dL and calculated (10.9 g/dL Hb concentrations for all cattle was significant (p < 0.001, whereas the difference in the means of determined Hb and corrected calculated Hb was not significant. In conclusion, a simplified relationship of Hb (g/dL = (0.3 PCV + 3 may provide a better estimate of Hb concentration from the PCV of cattle.

  16. Haemoglobin C and S role in acquired immunity against Plasmodium falciparum malaria.

    Directory of Open Access Journals (Sweden)

    Federica Verra

    2007-10-01

    Full Text Available A recently proposed mechanism of protection for haemoglobin C (HbC; beta6Glu-->Lys links an abnormal display of PfEMP1, an antigen involved in malaria pathogenesis, on the surface of HbC infected erythrocytes together with the observation of reduced cytoadhesion of parasitized erythrocytes and impaired rosetting in vitro. We investigated the impact of this hypothesis on the development of acquired immunity against Plasmodium falciparum variant surface antigens (VSA encoding PfEMP1 in HbC in comparison with HbA and HbS carriers of Burkina Faso. We measured: i total IgG against a single VSA, A4U, and against a panel of VSA from severe malaria cases in human sera from urban and rural areas of Burkina Faso of different haemoglobin genotypes (CC, AC, AS, SC, SS; ii total IgG against recombinant proteins of P. falciparum asexual sporozoite, blood stage antigens, and parasite schizont extract; iii total IgG against tetanus toxoid. Results showed that the reported abnormal cell-surface display of PfEMP1 on HbC infected erythrocytes observed in vitro is not associated to lower anti- PfEMP1 response in vivo. Higher immune response against the VSA panel and malaria antigens were observed in all adaptive genotypes containing at least one allelic variant HbC or HbS in the low transmission urban area whereas no differences were detected in the high transmission rural area. In both contexts the response against tetanus toxoid was not influenced by the beta-globin genotype. These findings suggest that both HbC and HbS affect the early development of naturally acquired immunity against malaria. The enhanced immune reactivity in both HbC and HbS carriers supports the hypothesis that the protection against malaria of these adaptive genotypes might be at least partially mediated by acquired immunity against malaria.

  17. Malaria and gravidity interact to modify maternal haemoglobin concentrations during pregnancy

    Directory of Open Access Journals (Sweden)

    Ouédraogo Smaïla

    2012-10-01

    Full Text Available Abstract Background Primigravidity is one of the main risk factors for both malaria and anaemia. Since the implementation of intermittent preventive treatment (IPTp in sub-Saharan Africa, the relationship between anaemia and gravidity and its evolution during pregnancy has been little explored. This study aimed to evaluate the impact of gravidity on the variation of haemoglobin during pregnancy according to the timing of gestation. Methods Data from three studies carried out in nearby areas in south Benin (Ouidah, Comé, Allada between 2005 and 2012 were analysed. At inclusion (first antenatal visit, ANV1 women’s age, area of residence, schooling, gravidity, gestational age, weight and height were recorded. Thick blood smears were performed on ANV1, second visit (ANV2 and at delivery. In Allada, women’s serum ferritin and CRP concentrations were also assessed. The impact of gravidity on maternal haemoglobin (Hb was analysed using a logistic or linear regression depending on the outcome. The statistical significance was set to P Results In total, data from 3,591 pregnant women were analysed. Both univariate and multivariate analyses showed a constant association between Hb concentrations and gravidity in the three periods of Hb assessment (ANV1, ANV2 and delivery. Mean Hb concentration was significantly lower in primigravidae than in multigravidae at ANV1 (mean difference = -2.4 g/L, CI 95%: [-3.4, -1.4], P Conclusion In a context of IPTp, Hb levels improved progressively throughout pregnancy in primigravidae, likely as a result of reduction in malaria infection. In multigravidae, the improvement was less perceptible and anaemia was mainly due to iron deficiency.

  18. Let's Make Data Count

    Science.gov (United States)

    Budden, A. E.; Abrams, S.; Chodacki, J.; Cruse, P.; Fenner, M.; Jones, M. B.; Lowenberg, D.; Rueda, L.; Vieglais, D.

    2017-12-01

    The impact of research has traditionally been measured by citations to journal publications and used extensively for evaluation and assessment in academia, but this process misses the impact and reach of data and software as first-class scientific products. For traditional publications, Article-Level Metrics (ALM) capture the multitude of ways in which research is disseminated and used, such as references and citations within social media and other journal articles. Here we present on the extension of usage and citation metrics collection to include other artifacts of research, namely datasets. The Make Data Count (MDC) project will enable measuring the impact of research data in a manner similar to what is currently done with publications. Data-level metrics (DLM) are a multidimensional suite of indicators measuring the broad reach and use of data as legitimate research outputs. By making data metrics openly available for reuse in a number of different ways, the MDC project represents an important first step on the path towards the full integration of data metrics into the research data management ecosystem. By assuring researchers that their contributions to scholarly progress represented by data corpora are acknowledged, data level metrics provide a foundation for streamlining the advancement of knowledge by actively promoting desirable best practices regarding research data management, publication, and sharing.

  19. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  20. Blood haemoglobin concentrations are higher in smokers and heavy alcohol consumers than in non-smokers and abstainers-should we adjust the reference range?

    DEFF Research Database (Denmark)

    Milman, N.; Pedersen, Agnes N.

    2009-01-01

    The blood haemoglobin concentration is one of the most frequently used laboratory parameters in clinical practice. There is evidence that haemoglobin levels are influenced by tobacco smoking. The objective of this study was to evaluate the impact of smoking and alcohol consumption on haemoglobin.......001) and women (r = 0.08, p = 0.05). In non-smokers, alcohol consumption > 14 drinks/week and more than seven drinks/week for men and women, respectively, increased mean haemoglobin by 1.3% in men and by average 1.9% in women compared with those consuming a parts per thousand currency sign14 and less than...... small changes in haemoglobin do not justify the use of separate reference ranges in smokers and alcohol consumers....

  1. Association between glycated haemoglobin and the risk of congestive heart failure in diabetes mellitus : systematic review and meta-analysis

    NARCIS (Netherlands)

    Erqou, Sebhat; Lee, Chee-Tin Christine; Suffoletto, Matthew; Echouffo-Tcheugui, Justin B.; de Boer, Rudolf A.; van Melle, Joost P.; Adler, Amanda I.

    Clinical trials to date have not provided definitive evidence regarding the effects of glucose lowering on the incidence of congestive heart failure (CHF). We synthesized available prospective epidemiological data on the association between glycaemia measured by haemoglobin A(1c) (HbA(1c)) and

  2. Socioeconomic determinants of haemoglobin levels of African women are less important in areas with more health facilities: a multilevel analysis

    NARCIS (Netherlands)

    Haverkate, M; Smits, J.P.J.M.; Meijerink, H.; Ven, André van der

    2014-01-01

    BACKGROUND : The prevalence of anaemia in Africa is the highest in the world. Especially women are at risk because of blood loss during menstruation and increased iron requirements during pregnancy. This study examined determinants of the haemoglobin (Hb) level of African women at

  3. Effects of Rambutan Peel Extract to The Number of Erythrocytes and Haemoglobin in Rats Exposed to Cigarette Smoke

    Science.gov (United States)

    Lisdiana; Dewi, F. K.

    2017-04-01

    Cigarette smoke is one of the exogenous free radicals sources. When it is inhaled, its activity may damage the structure of erythrocyte membrane function. The impacts of free radicals can be reduced through the provision of antioxidants. Rambutan fruit peel contains the phenolic compound in the form of polyphenols that are antioxidants. The purpose of this study is to determine the effect of rambutan fruit peel extracts to the number of erythrocytes and haemoglobin in rats exposed to cigarette smoke. This design used Post Test Control Group Design. A sample of 25 rats was divided into five groups, each group consisting of 5 rats. The positive control group (K+) were given a standard food and drinking water. The negative control group (K) by three cigarettes, the treatment group (KP1, KP2, KP3) by three cigarettes and skin extract of rambutan each treatment group with a dose 15 mg/kg, 30 mg/kg and 45 mg/kg for 30 days. Data on the number of erythrocytes and haemoglobin in rat blood was analysed with LSD and to determine the optimum dosage was analysed by using regression test. Research results shown that the content of rambutan fruit peel extract may increase the number of erythrocytes and haemoglobin of blood. Conclusions from this research are the rambutan fruit peel extract at a dose of 45 mg/kg body weight can increase and maintain the number of erythrocytes and haemoglobin in the blood of rat exposed to cigarette smoke.

  4. Detection of haemoglobins with abnormal oxygen affinity by single blood gas analysis and 2,3-diphosphoglycerate measurement.

    Science.gov (United States)

    Guerrini, G; Morabito, A; Samaja, M

    2000-10-01

    The aim is to determine if a single measurement of blood 2,3-diphosphoglycerate combined with gas analysis (pH, PCO2, PO2 and saturation) can identify the cause of an altered blood-oxygen affinity: the presence of an abnormal haemoglobin or a red cell disorder. The population (n=94) was divided into healthy controls (A, n=14), carriers of red cell disorders (B, n=72) and carriers of high oxygen affinity haemoglobins (C, n=8). Those variables were measured both in samples equilibrated at selected PCO2 and PO2 and in venous blood. In the univariable approach applied to equilibrated samples, we correctly identified C subjects in 93.6% or 96.8% of the cases depending on the selected variable, the standard P50 (PO2 at which 50% of haemoglobin is oxygenated) or a composite variable calculated from the above measurements. After introducing the haemoglobin concentration as a further discriminating variable, the A and B subjects were correctly identified in 91.9% or 94.2% of the cases, respectively. These figures become 93.0% or 86.1%, and 93.7% or 94.9% of the cases when using direct readings from venous blood, thereby avoiding the blood equilibration step. This test is feasible also in blood samples stored at 4 degrees C for 48 h, or at room temperature for 8 h.

  5. Anaemia during pregnancy: impact on birth outcome and infant haemoglobin level during the first 18 months of life.

    Science.gov (United States)

    Koura, Ghislain K; Ouedraogo, Smaïla; Le Port, Agnès; Watier, Laurence; Cottrell, Gilles; Guerra, José; Choudat, Isabelle; Rachas, Antoine; Bouscaillou, Julie; Massougbodji, Achille; Garcia, André

    2012-03-01

    To determine the effect of maternal anaemia on pregnancy outcome and describe its impact on infant haemoglobin level in the first 18 months of life, we conducted a prospective study of 617 pregnant women and their children in Benin. Prevalence of maternal anaemia at delivery was 39.5%, and 61.1% of newborns were anaemic at birth. Maternal anaemia was not associated with low birth weight [OR = 1.2 (0.6-2.2)] or preterm birth [OR = 1.3 (0.7-2.4)], whereas the newborn's anaemia was related to maternal anaemia [OR = 1.8 (1.2-2.5)]. There was no association between an infant's haemoglobin level until 18 months and maternal anaemia. However, malaria attacks during follow-up, male gender and sickle cell trait were all associated with a lower infant haemoglobin level until 18 months, whereas good infant feeding practices and a polygamous family were positively associated with a higher haemoglobin level during the first 18 months of life. © 2011 Blackwell Publishing Ltd.

  6. Limited influence of haemoglobin variants on Plasmodium falciparum msp1 and msp2 alleles in symptomatic malaria

    NARCIS (Netherlands)

    Mockenhaupt, Frank P.; Ehrhardt, Stephan; Otchwemah, Rowland; Eggelte, Teunis A.; Anemana, Sylvester D.; Stark, Klaus; Bienzle, Ulrich; Kohne, Elisabeth

    2004-01-01

    Haemoglobin (Hb) S, HbC, and alpha(+)-thalassaemia confer protection from malaria. Accordingly, these traits may influence the multiplicity of infection (MOI) of Plasmodium falciparum and the presence of distinct parasite genotypes. In 840 febrile children in northern Ghana, we typed the P.

  7. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  8. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  9. Taxonomy, phylogenetics and biogeography of Chesneya (Fabaceae), evidenced from data of three sequences, ITS, trnS-trnG, and rbcL

    Science.gov (United States)

    Ming-Li Zhang; Zhi-Bin Wen; Xiao-Li Hao; Vyacheslav V. Byalt; Alexander P. Sukhorukov; Stewart C. Sanderson

    2015-01-01

    Plants of Central Asia have played a significant role in the origin of floras of Eurasia and the Northern Hemisphere. Chesneya, a small leguminous genus occurring in Central Asia, western Asia, and Tibet, is used to establish phylogenetic relationships and discuss the evolutionary and biogeographical history based on sequence data of ITS and trnS-trnG and rbcL.We...

  10. Use of rbcL and trnL-F as a two-locus DNA barcode for identification of NW-European ferns: an ecological perspective

    NARCIS (Netherlands)

    Groot, de G.A.; During, H.J.; Maas, J.W.; Schneider, H.; Erkens, R.H.J.

    2011-01-01

    Although consensus has now been reached on a general two-locus DNA barcode for land plants, the selected combination of markers (rbcL + matK) is not applicable for ferns at the moment. Yet especially for ferns, DNA barcoding is potentially of great value since fern gametophytes—while playing an

  11. Studies on Dasyaceae. 3. Towards a phylogeny of the Dasyaceae (Ceramiales, Rhodophyta), based on comparative rbcL gene sequences and morphology

    NARCIS (Netherlands)

    de Jong, Y.S D M; van der Wurff, A.W G; Stam, W.T.; Olsen, J.L.

    Phylogenetic analyses of the Dasyaceae based on sequence analysis of the large subunit of ribulose-1,5-bisphosphate carboxylase/oxygenase (rbcL) and 42 morphological characters are presented. Comparative sequence analysis confirms the general view of the Ceramiaceae as a primitive, paraphyletic

  12. RBC-coupled tPA prevents cerebrovasodilatory impairment and tissue injury in pediatric cerebral hypoxia/ischemia through inhibition of ERK MAPK unregulation

    Energy Technology Data Exchange (ETDEWEB)

    Ganguly, Kumkum [Los Alamos National Laboratory; Armstead, William M [U PENNSYLVANIA; Kiessling, J W [U PENNSYLVANIA; Chen, Xiao - Han [U PENNSYLVANIA; Smith, Douglas H [U PENNSYLVANA; Higazi, Abd Ar [U PENNSYLVANIA; Cines, Douglas B [U PENNSYLVANIA; Bdeir, Khalil [U PENNSYLVANIA; Zaitsev, Sergei [U PENNSYLVANIA; Muzykantov, Vladimir R [U PENNSYLVANIA

    2008-01-01

    Babies experience hypoxia (H) and ischemia (I) from stroke. The only approved treatment for stroke is fibrinolytic therapy with tissue-type plasminogen activator (tPA). However, tPA potentiates H/I-induced impairment of responses to cerebrovasodilators such as hypercapnia and hypotension, and blockade of tPA-mediated vasoactivity prevents this deleterious effect. Coupling tPA to RBCs reduces its CNS toxicity through spatially confining the drug to the vasculature. Mitogen activated protein kinase (MAPK), a family of at least 3 kinases, is upregulated after H/I. In this study we determined if RBC-tPA given before or after cerebral H/I would preserve responses to cerebrovasodilators and prevent neuronal injury mediated through the ERK MAPK pathway. Animals given RBC-tPA maintained responses to cerebrovasodilators at levels equivalent to pre-H/I values. CSF and brain parenchymal ERK MAPK was elevated by H/I and this upregulation was potentiated by tPA, but blunted by RBC-tPA. U 0126, an ERK MAPK antagonist, also maintained cerebrovasodilation post H/I. Neuronal degeneration in CA1 hippocampus and parietal cortex after H/I was exacerbated by tPA, but ameliorated by RBC-tPA and U 0126. These data suggest that coupling tPA to RBCs may offer a novel approach towards increasing the benefit/risk ratio of thrombolytic therapy for CNS disorders associated with H/I.

  13. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  14. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  15. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  16. Etiology of cardiogenic shock early after open-heart surgery: Assessment by Tc-99m RBC wall motion scintigraphy

    International Nuclear Information System (INIS)

    Bateman, T.; Gray, R.; Chaux, A.; Lee, M.; Matloff, J.; Raymond, M.; Berman, D.

    1984-01-01

    When life-threatening cardiogenic shock (CI 1.8 1/min/m/sup 2/, elevated right and left-side filling pressures) occurs early (0-48 hrs) after open-heart surgery, routine approaches frequently cannot distinguish between expected etiologies: (1) transient systolic failure of the LV, RV, or both, common early postoperatively (postop); (2) perioperative infarct of the LV or RV; (3) myocardial restriction due to active pericardial bleeding or to accumulated clots and fluid; (4) diminished LV reserve from aneurysmectomy; and (5) residual valvular regurgitation. Distinction is critical, because (1), (2), and (4) will be treated by optimizing preload and afterload; (3) with urgent (if active bleeding) or semi-urgent surgery; and (5) with repeat valvular surgery. In 22 pts with unexpected early postop cardiogenic shock, Tc-99m-RBC equilibrium radionuclide ventriculography revealed: global LV (3 pts) or RV (3 pts) dysfunction, new segmental LV dysfunction (2 pts), active bleeding (5 pts) and/or accumulated pericardial fluid ( 8 pts) with hyperdynamic LV and RV, and a small hyperdynamic LV without effusion (1 pt), providing a specific etiologic diagnosis in all cases. In the Cardiac Surgical ICU, therapeutic decisions frequently await and depend on the results of equilibrium radionuclide ventriculography, now routinely performed in postop pts with unexpected cardiogenic shock

  17. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats-Multiple factorial regression analysis.

    Science.gov (United States)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-02-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200-240g for 28days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight antagonism

  18. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats—Multiple factorial regression analysis

    International Nuclear Information System (INIS)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-01-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200–240 g for 28 days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15 mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000 mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight

  19. Foetal haemoglobin and disease severity in sickle cell anaemia patients in Kampala, Uganda

    Directory of Open Access Journals (Sweden)

    Mpalampa Lena

    2012-09-01

    Full Text Available Abstract Background Sickle cell anaemia (SCA is a major chronic health problem in Uganda. In patients with SCA, the level of foetal haemoglobin (HbF has been found to be important in influencing the clinical course of the disease. Thus populations with high levels of HbF like those in Saudi Arabia have been described as having a milder clinical course with fewer complications as compared to populations with lower levels. Disease modifying drugs can increase the Hb F levels and modify the presentation of SCA. Methods This was a cross sectional study in which we determined foetal haemoglobin levels and examined the relationship between HbF levels and disease severity in SCA patients in Mulago Hospital, Kampala, Uganda. We consecutively enrolled 216 children aged 1 year to 18 years with SCA attending the Sickle Cell Clinic at Mulago Hospital whose guardians had given consent. The history included age at onset of initial symptoms and diagnosis, number of hospitalisations and blood transfusions and other complications of SCA (cardiovascular accidents, avascular hip necrosis and priapism. A detailed physical examination was performed to assess the current state and help describe the disease severity for each patient. Blood samples were drawn for HbF levels. HbF levels ≥10% was defined as high. Results Of the 216 children, (80 37% had HbF levels ≥10%. Significant correlations were observed between HbF level and several clinical parameters independent of age including age at diagnosis (p value 0.013, number of hospitalisations (p value 0.024 and transfusions (p value 0.018 since birth. Conclusion A third of the children with SCA attending the Sickle cell clinic in Mulago Hospital have high HbF levels. Higher HbF level is associated with later onset of symptoms and presentation, and less severe disease characterised by fewer hospitalisations and blood transfusions. We suggest HbF levels should be determined at initial contact for patients with SCA to

  20. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  1. RBC urine test

    Science.gov (United States)

    ... measurement for a result of this test. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...

  2. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  3. Measuring glycated haemoglobin in women with gestational diabetes mellitus: How useful is it?

    Science.gov (United States)

    Wong, Vincent W; Chong, Shanley; Mediratta, Sahil; Jalaludin, Bin

    2017-06-01

    Glycated haemoglobin (HbA1c) is an important tool for assessing glycaemic status in patients with diabetes, but its usefulness in gestational diabetes mellitus (GDM), is unclear. The aim of this study is to evaluate whether HbA1c in women with GDM is valuable in predicting adverse pregnancy outcomes. A retrospective review of women with GDM who had HbA1c measured at diagnosis of GDM (GHb-diag) and at 36 weeks gestation (GHb-36 weeks) was conducted. The association between HbA1c and various pregnancy outcomes was assessed RESULTS: Among 1244 women with GDM in our cohort, both GHb-diag and GHb-36 weeks were independent predictors for large-for-gestation (LGA) babies (OR 1.06, P = 0.005 and OR 1.06, P = 0.002, respectively) and neonatal hypoglycaemia (OR 1.10, P 5.4% or 35 mmol/mol) at diagnosis of GDM should be monitored closely during pregnancy. However, there is not enough evidence to suggest that repeating HbA1c toward the end of pregnancy will provide additional information in predicting adverse pregnancy outcomes. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  4. Constitutive expression of Vitreoscilla haemoglobin in Sphingomonas elodea to improve gellan gum production.

    Science.gov (United States)

    Wu, X C; Chen, Y M; Li, Y D; Li, O; Zhu, L; Qian, C D; Tao, X L; Teng, Y

    2011-02-01

    To improve a commercially used strain for gellan production by exogenous Vitreoscilla haemoglobin (VHb). VHb gene was expressed in Sphingomonas elodea under the control of constitutive bla promoter. Biochemical activity of expressed VHb was confirmed by CO-difference spectra analysis that exhibited a characteristic absorption maximum at 419 nm. During cultivation, not only enhanced cell growth was detected, but also 20% improvement in gellan production was observed after 48 h of incubation, with a maximum yield of 16·82 g l(-1). Moreover, maximum sucrose conversion efficiency (g gellan per g sucrose) was 57·8, 20% higher than that of the parental strain. We further examined the polysaccharide production of VHb-expressing strain at different aeration levels in Erlenmeyer flasks. Again, in all cases, a significant enhancement of gellan production was observed, and the enhancement was more significant under oxygen-limiting conditions (up to 26·8%). VHb exhibited positive effect on cell growth and gellan yield of S. elodea, especially under hypoxic conditions. This is the first application of VHb as an effective metabolic engineering strategy in S. elodea to regulate cell growth and optimize gellan yield. © 2010 The Authors. Journal of Applied Microbiology © 2010 The Society for Applied Microbiology.

  5. Adaptation to extreme environments: structure-function relationships in Emperor penguin haemoglobin.

    Science.gov (United States)

    Tamburrini, M; Condò, S G; di Prisco, G; Giardina, B

    1994-04-15

    The functional properties of the single haemoglobin (Hb) of Emperor penguin (Aptenodytes forsteri) have been investigated at different temperatures as a function of proton and organic phosphate concentration. The complete amino acid sequence has been established. Comparison with that of human HbA shows 12 substitutions in the contact regions of alpha beta dimers. In addition to overall similarities shared with most of the avian Hbs previously described, this Hb shows significant differences, which could be related to the peculiar behaviour of this penguin. In particular we may consider that: (1) the shape of the Bohr effect curve seems well adapted for gas exchange during very prolonged dives, preserving penguin Hb from a sudden and not controlled stripping of oxygen; (2) the very minor enthalpy change observed at lower pH could be an example of molecular adaptation, through which oxygen delivery becomes essentially insensitive to exposure to the extremely low temperatures of the environment. Moreover, the small alkaline Bohr effect has been found to be only chloride-linked, since the pH dependence of the oxygen affinity is totally abolished in the absence of this ion. These functional characteristics are discussed on the basis of the primary structure of alpha and beta-chains.

  6. Relationship between changes in haemoglobin mass and maximal oxygen uptake after hypoxic exposure.

    Science.gov (United States)

    Saunders, Philo U; Garvican-Lewis, Laura A; Schmidt, Walter F; Gore, Christopher J

    2013-12-01

    Endurance athletes have been using altitude training for decades to improve near sea-level performance. The predominant mechanism is thought to be accelerated erythropoiesis increasing haemoglobin mass (Hb(mass)) resulting in a greater maximal oxygen uptake (VO₂(max)). Not all studies have shown a proportionate increase in VO₂(max) as a result of increased Hb(mass). The aim of this study was to determine the relationship between the two parameters in a large group of endurance athletes after altitude training. 145 elite endurance athletes (94 male and 51 female) who participated in various altitude studies as altitude or control participants were used for the analysis. Participants performed Hb(mass) and VO₂(max) testing before and after intervention. For the pooled data, the correlation between per cent change in Hb(mass) and per cent change in VO₂(max) was significant (pstatistical power, we conclude that altitude training of endurance athletes will result in an increase in VO₂(max) of more than half the magnitude of the increase in Hb(mass), which supports the use of altitude training by athletes. But race performance is not perfectly related to relative VO₂(max), and other non-haematological factors altered from altitude training, such as running economy and lactate threshold, may also be beneficial to performance.

  7. Stability and reliability of glycated haemoglobin measurements in blood samples stored at -20°C.

    Science.gov (United States)

    Venkataraman, Vijayachandrika; Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Jayashri, Ramamoorthy; Anbalagan, Viknesh Prabu; Akila, Bridgitte; Madhu, Sri Venkata; Lakshmy, Ramakrishnan; Mohan, Viswanathan

    2016-01-01

    To validate the stability of glycated haemoglobin (HbA1c) measurements in blood samples stored at -20°C for up to one month. The study group comprised 142 type 2 diabetic subjects visiting a tertiary centre for diabetes at Chennai city in south India. The HbA1c assay was done on a fasting blood sample using the Bio-Rad Variant machine on Day 0 (day of blood sample collection). Several aliquots were stored at -20°C and the assay was repeated on the 3rd, 7th, 15th, and 30th day after the sample collection. Bland-Altman plots were constructed and variation in the HbA1c levels on the different days was compared with the day 0 level. The median differences between HbA1c levels measured on Day 0 and the 3rd, 7th, 15th, and 30th day after blood collection were 0.0%, 0.2%, 0.3% and 0.5% respectively. Bland-Altman plot analysis showed that the differences between the day '0' and the different time points tend to get larger with time, but these were not clinically significant. HbA1c levels are relatively stable up to 2weeks, if blood samples are stored at -20°C. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Iron from haemoglobin and haemin modulates nucleotide hydrolysis in Trichomonas vaginalis.

    Science.gov (United States)

    Vieira, Patrícia de Brum; Silva, Nícolas Luiz Feijó; Kist, Luiza Wilges; Oliveira, Giovanna Medeiros Tavares de; Bogo, Maurício Reis; Carli, Geraldo Atillio de; Macedo, Alexandre José; Tasca, Tiana

    2015-04-01

    Extracellular ATP may act as a danger signalling molecule, inducing inflammation and immune responses in infection sites. The ectonucleotidases NTPDase and ecto-5'-nucleotidase are enzymes that modulate extracellular nucleotide levels; these enzymes have been previously characterised in Trichomonas vaginalis. Iron plays an important role in the complex trichomonal pathogenesis. Herein, the effects of iron on growth, nucleotide hydrolysis and NTPDase gene expression in T. vaginalis isolates from female and male patients were evaluated. Iron from different sources sustained T. vaginalis growth. Importantly, iron from haemoglobin (HB) and haemin (HM) enhanced NTPDase activity in isolates from female patients and conversely reduced the enzyme activity in isolates from male patients. Iron treatments could not alter the NTPDase transcript levels in T. vaginalis. Furthermore, our results reveal a distinct ATP, ADP and AMP hydrolysis profile between isolates from female and male patients influenced by iron from HB and HM. Our data indicate the participation of NTPDase and ecto-5'-nucleotidase in the establishment of trichomonas infection through ATP degradation and adenosine production influenced by iron.

  9. Iron from haemoglobin and haemin modulates nucleotide hydrolysis in Trichomonas vaginalis

    Directory of Open Access Journals (Sweden)

    Patrícia de Brum Vieira

    2015-04-01

    Full Text Available Extracellular ATP may act as a danger signalling molecule, inducing inflammation and immune responses in infection sites. The ectonucleotidases NTPDase and ecto-5’-nucleotidase are enzymes that modulate extracellular nucleotide levels; these enzymes have been previously characterised in Trichomonas vaginalis. Iron plays an important role in the complex trichomonal pathogenesis. Herein, the effects of iron on growth, nucleotide hydrolysis and NTPDase gene expression in T. vaginalis isolates from female and male patients were evaluated. Iron from different sources sustained T. vaginalis growth. Importantly, iron from haemoglobin (HB and haemin (HM enhanced NTPDase activity in isolates from female patients and conversely reduced the enzyme activity in isolates from male patients. Iron treatments could not alter the NTPDase transcript levels in T. vaginalis. Furthermore, our results reveal a distinct ATP, ADP and AMP hydrolysis profile between isolates from female and male patients influenced by iron from HB and HM. Our data indicate the participation of NTPDase and ecto-5’-nucleotidase in the establishment of trichomonas infection through ATP degradation and adenosine production influenced by iron.

  10. Glycated haemoglobin: A marker of circulating lipids in patients with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Sheikh Ishaq

    2017-01-01

    Full Text Available Introduction: Type 2 diabetes mellitus (T2DM is a group of metabolic disorder and is an independent risk factor for cardiovascular disease and dyslipidaemia. Patients with T2DM have dyslipidaemia at wavering degrees, characterised by increased levels of triglyceride and low-density lipoprotein-cholesterol and decreased levels of high-density lipoprotein (HDL-cholesterol. In the present study, we evaluated glycated haemoglobin (HbA1c as a marker of circulating lipids in patients with T2DM. Methods: Two hundred and thirty-nine patients with T2DM were enrolled for the study. A detailed biochemical and lipid profile was done for all patients. Results: Of 239 cases, 96 (40% were male and 143 (60% were female. Of 239 patients, 53 (22% patients with T2DM had controlled glycaemia (HbA1c <6.5 and 186 (78% patients had uncontrolled glycaemia (HbA1c ≥6.5. Pearson's correlation of HbA1c with all lipid parameters was statistically significant. HbA1c, however, had an inverse correlation with HDL and had a significant direct correlation with fasting blood glucose. Conclusion: The study reveals that HbA1c is not only a reliable glycaemic index but can also be used as an important indicator of dyslipidaemia in patients with T2DM.

  11. Haemoglobin status and predictors of anaemia among pregnant women in Mpigi, Uganda.

    Science.gov (United States)

    Ononge, Sam; Campbell, Oona; Mirembe, Florence

    2014-10-10

    Anaemia in pregnancy is a major public health problem especially in the low-income countries where it is highly prevalent. There has been no recent study in Uganda about the factors associated with anaemia in pregnancy. We aimed to assess the current haemoglobin (Hb) status and factors associated with anaemia (Hb anaemia were estimated using linear and logistic regression analysis. The mean Hb was 11.5 (± 1.38) g/dl and prevalence of anaemia (Hb anaemia in pregnancy were malaria infection (OR: 1.32, 95% CI: 1.11, 1.58), Human Immuno-deficiency Virus infection (OR: 2.13, 95% CI: 1.36, 2.90) and lack of iron supplementation (OR: 1.66, 95% CI: 1.36, 2.03). Intermittent presumptive treatment of malaria, maternal age and parity showed a weak association with anaemia in pregnancy The high prevalence of anaemia in pregnancy in our setting highlights the need to put more effort in the fight against malaria and HIV, and also ensure that pregnant women access iron supplements early in pregnancy.

  12. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  13. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  14. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  15. Reconstructing a herbivore’s diet using a novel rbcL DNA mini-barcode for plants

    Science.gov (United States)

    Erickson, David L.; Reed, Elizabeth; Ramachandran, Padmini; Bourg, Norman; McShea, William J.; Ottesen, Andrea

    2017-01-01

    Next Generation Sequencing and the application of metagenomic analyses can be used to answer questions about animal diet choice and study the consequences of selective foraging by herbivores. The quantification of herbivore diet choice with respect to native versus exotic plant species is particularly relevant given concerns of invasive species establishment and their effects on ecosystems. While increased abundance of white-tailed deer (Odocoileus virginianus) appears to correlate with increased incidence of invasive plant species, data supporting a causal link is scarce. We used a metabarcoding approach (PCR amplicons of the plant rbcL gene) to survey the diet of white-tailed deer (fecal samples), from a forested site in Warren County, Virginia with a comprehensive plant species inventory and corresponding reference collection of plant barcode and chloroplast sequences. We sampled fecal pellet piles and extracted DNA from 12 individual deer in October 2014. These samples were compared to a reference DNA library of plant species collected within the study area. For 72 % of the amplicons, we were able to assign taxonomy at the species level, which provides for the first time—sufficient taxonomic resolution to quantify the relative frequency at which native and exotic plant species are being consumed by white-tailed deer. For each of the 12 individual deer we collected three subsamples from the same fecal sample, resulting in sequencing 36 total samples. Using Qiime, we quantified the plant DNA found in all 36 samples, and found that variance within samples was less than variance between samples (F = 1.73, P = 0.004), indicating additional subsamples may not be necessary. Species level diversity ranged from 60 to 93 OTUs per individual and nearly 70 % of all plant sequences recovered were from native plant species. The number of species detected did reduce significantly (range 4–12) when we excluded species whose OTU composed behaviour may favour

  16. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  17. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  18. NIGERIAN VETERINARY JOURNAL

    African Journals Online (AJOL)

    ADEYEYE

    The effect of Guiera senegalensis leaf extract was investigated on the blood parameters of albino ... (PCV), Haemoglobin concentration (Hb), Red blood cell count (RBC) and White blood cell ... membranes in the infected hosts, confirming .... stable up to day 20 post infection. A ..... stimulating and anti-inflammatory effects.

  19. Structural studies of haemoglobin from pisces species shortfin mako shark (Isurus oxyrinchus) at 1.9 Å resolution

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, Pandian, E-mail: prms23@gmail.com [Samsung Biomedical Research Institute, Sungkyunkwan University School of Medicine, Suwon 440-746 (Korea, Republic of); University of Madras, Maraimalai Campus (Guindy), Chennai 600 025 (India); Sundaresan, S. S.; Sathya Moorthy, Pon.; Balasubramanian, M.; Ponnuswamy, M. N. [University of Madras, Maraimalai Campus (Guindy), Chennai 600 025 (India)

    2013-11-01

    Shortfin mako shark haemoglobin adopts an unliganded deoxy T state conformation, which is shown from the quaternary structural features, interface interactions and heme binding sites of different subunits of haemoglobin with high-resolution X-ray data. Haemoglobin (Hb) is a tetrameric iron-containing protein that carries oxygen from the lungs to tissues and carbon dioxide from tissues back to the lungs. Pisces are the advanced aquatic vertebrates capable of surviving at wide depth ranges. The shortfin mako shark (SMS) is the pelagic, largest, fastest and most sophisticated species of the shark kingdom with well developed eyes. Mostly the pisces species are cold blooded in nature. Distinctly, the SMSs are warm-blooded animals with an advanced circulatory system. SMSs are capable of maintaining elevated muscle temperatures up to 33 K above the ambient water temperatures at a depth of 150–500 m. SMSs have a diverged air-breathing mechanism compared with other vertebrates. The haemoglobin molecule consists of four polypeptide chains, namely two α chains, each with 140 amino acids and two β chains each having 136 amino acids. The SMS Hb was found to crystallize in monoclinic space group P2{sub 1} using the hanging-drop vapour-diffusion method at room temperature. The crystal packing parameters for the SMS Hb structure contain one whole biological molecule in the asymmetric unit with a solvent content of 47%. The SMS Hb quaternary structural features interface–interface interactions and heme binding sites are discussed with different state Hbs and the results reveal that SMS Hb adopts an unliganded deoxy T state conformation.

  20. Structural studies of haemoglobin from pisces species shortfin mako shark (Isurus oxyrinchus) at 1.9 Å resolution

    International Nuclear Information System (INIS)

    Ramesh, Pandian; Sundaresan, S. S.; Sathya Moorthy, Pon.; Balasubramanian, M.; Ponnuswamy, M. N.

    2013-01-01

    Shortfin mako shark haemoglobin adopts an unliganded deoxy T state conformation, which is shown from the quaternary structural features, interface interactions and heme binding sites of different subunits of haemoglobin with high-resolution X-ray data. Haemoglobin (Hb) is a tetrameric iron-containing protein that carries oxygen from the lungs to tissues and carbon dioxide from tissues back to the lungs. Pisces are the advanced aquatic vertebrates capable of surviving at wide depth ranges. The shortfin mako shark (SMS) is the pelagic, largest, fastest and most sophisticated species of the shark kingdom with well developed eyes. Mostly the pisces species are cold blooded in nature. Distinctly, the SMSs are warm-blooded animals with an advanced circulatory system. SMSs are capable of maintaining elevated muscle temperatures up to 33 K above the ambient water temperatures at a depth of 150–500 m. SMSs have a diverged air-breathing mechanism compared with other vertebrates. The haemoglobin molecule consists of four polypeptide chains, namely two α chains, each with 140 amino acids and two β chains each having 136 amino acids. The SMS Hb was found to crystallize in monoclinic space group P2 1 using the hanging-drop vapour-diffusion method at room temperature. The crystal packing parameters for the SMS Hb structure contain one whole biological molecule in the asymmetric unit with a solvent content of 47%. The SMS Hb quaternary structural features interface–interface interactions and heme binding sites are discussed with different state Hbs and the results reveal that SMS Hb adopts an unliganded deoxy T state conformation

  1. The Crossmatch/Issue Ratio:  Use of a Novel Quality Indicator and Results of an International Survey on RBC Crossmatching and Issuing Practices

    DEFF Research Database (Denmark)

    Yazer, Mark H; Alcantara, Ramir; Beizai, Pouneh

    2016-01-01

    OBJECTIVES: To understand the worldwide scope of RBC crossmatching and issuing practices and measure efficiency using a novel quality indicator, the crossmatch/issue (C/I) ratio. METHODS: An electronic survey was disseminated to hospital transfusion services collecting details about RBC...... crossmatching and issuing practices. Respondents were asked to enumerate the number of RBCs crossmatched and issued at their institutions during the 2014 calendar year to calculate the C/I ratio. RESULTS: Fifty-two survey responses were received, mostly from North American transfusion services (28/52, 54......%). The electronic crossmatch was the most common technique (n = 29), and most respondents performed the crossmatch at the time that an order for RBCs was received in the transfusion service (even if an order to issue the RBCs was not received). Data to calculate the C/I ratio were supplied by 22 respondents...

  2. R and G color component competition of RGB image decomposition as a criterion to register RBC agglutinates for blood group typing.

    Science.gov (United States)

    Doubrovski, Valeri A; Ganilova, Yuliya A; Zabenkov, Igor V

    2014-03-01

    A new approach of the criterion assignment for registration of erythrocyte agglutinates to instrumentally determine blood group type is suggested. The criterion is based on comparison of R and G components of RGB decomposition of microscopy digital image taken for the blood-serum mixture sample. For the chosen experimental conditions, the minimal size (area) of RBC agglutinate to be registered by the criterion suggested is estimated theoretically. The proposed method was tested experimentally on the example of monitoring agglutinates in flow. The encouraging experimental results were obtained for improvement of the resolving power of the method; the optimal experimental conditions were revealed for maximum resolution. Though the suggested method was realized for dynamic (flow) blood group determination, it could also be applied for diagnostics in a stationary environment. This approach increases the reliability of RBC agglutinates registration and, hence, blood group typing. The results may be used to develop the apparatus for automated determination of human blood group.

  3. Effects of prolonged compression on the variations of haemoglobin oxygenation-assessment by spectral analysis of reflectance spectrophotometry signals

    International Nuclear Information System (INIS)

    Li, Zengyong; Tam, Eric W C; Mak, Arthur F T; Lau, Roy Y C

    2006-01-01

    The consequences of rhythmical flow motion for nutrition and the oxygen supply to tissue are largely unknown. In this study, the periodic variations of haemoglobin oxygenation in compressed and uncompressed skin were evaluated with a reflection spectrometer using an in vivo Sprague-Dawley rat model. Skin compression was induced over the trochanter area by a locally applied external pressure of 13.3 kPa (100 mmHg) via a specifically designed pneumatic indentor. A total of 19 rats were used in this study. The loading duration is 6 h per day for four consecutive days. Haemoglobin oxygenation variations were quantified using spectral analysis based on wavelets' transformation. The results found that in both compressed and uncompressed skin, periodic variations of the haemoglobin oxygenation were characterized by two frequencies in the range of 0.01-0.05 Hz and 0.15-0.4 Hz. These frequency ranges coincide with those of the frequency range of the endothelial-related metabolic and myogenic activities found in the flow motion respectively. Tissue compression following the above loading schedule induced a significant decrease in the spectral amplitudes of frequency interval 0.01-0.05 Hz during the pre-occlusion period on day 3 and day 4 as compared to that on day 1 (p 2 consumption rates of arteriolar walls. The modification of vessel wall oxygen consumption might substantially affect the available oxygen supply to the compressed tissue. This mechanism might be involved in the process leading to pressure ulcer formation

  4. Purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies of great cormorant (Phalacrocorax carbo) haemoglobin

    International Nuclear Information System (INIS)

    Jagadeesan, G.; Malathy, P.; Gunasekaran, K.; Harikrishna Etti, S.; Aravindhan, S.

    2014-01-01

    The great cormorant hemoglobin has been isolated, purified and crystallized and the three dimensional structure is solved using molecular replacement technique. Haemoglobin is the iron-containing oxygen-transport metalloprotein that is present in the red blood cells of all vertebrates. In recent decades, there has been substantial interest in attempting to understand the structural basis and functional diversity of avian haemoglobins. Towards this end, purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies have been carried out on cormorant (Phalacrocorax carbo) haemoglobin. Crystals were grown by the hanging-drop vapour-diffusion method using PEG 3350, NaCl and glycerol as precipitants. The crystals belonged to the trigonal system P3 1 21, with unit-cell parameters a = b = 55.64, c = 153.38 Å, β = 120.00°; a complete data set was collected to a resolution of 3.5 Å. Matthews coefficient analysis indicated that the crystals contained a half-tetramer in the asymmetric unit

  5. Pathophysiological effects and changes in potassium, ionised calcium, glucose and haemoglobin early after severe blunt chest trauma.

    Science.gov (United States)

    Rocksén, David; Gryth, Dan; Druid, Henrik; Gustavsson, Jenny; Arborelius, Ulf P

    2012-05-01

    Severe lung contusion is often observed after blunt chest trauma due to traffic accidents or fall from heights, but may also occur after a non-penetrating ballistic impact against body armour. Such trauma has been designated behind armour blunt trauma (BABT). Our aim in the present study has been to evaluate pathophysiological changes and compensatory mechanisms that occur early after such severe lung contusion. Twelve pigs wearing body armour were shot with a 7.62mm assault rifle to produce a standardised pulmonary contusion. Exposed animals were compared with five control animals shot with blank ammunition. Physiological parameters and levels of potassium, glucose, haemoglobin, calcium, lactate and pH were monitored for two hours after the shot. The impact induced severe pulmonary contusion with apnoea, desaturation and hypotension in all exposed animals. Increased haemoglobin, glucose and severe hyperkalaemia were seen shortly after impact. Seven of twelve animals died due to the trauma. Dense cardiac tissue was observed during post mortem examination in six of the animals that died during the experimental course. In conclusion, this study has shown that life-threatening hyperkalaemia occurs early after severe lung contusion. Moreover, dense cardiac tissue and early increase of haemoglobin and glucose are intriguing findings that should be investigated in future studies. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies of great cormorant (Phalacrocorax carbo) haemoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Jagadeesan, G. [Presidency College, Chennai 600 005 (India); Malathy, P.; Gunasekaran, K. [University of Madras, Chennai 600 025 (India); Harikrishna Etti, S. [GKM College of Engineering and Technology, Kamaraj Salai, Chennai 600 063 (India); Aravindhan, S., E-mail: aravindhanpresidency@gmail.com [Presidency College, Chennai 600 005 (India)

    2014-10-25

    The great cormorant hemoglobin has been isolated, purified and crystallized and the three dimensional structure is solved using molecular replacement technique. Haemoglobin is the iron-containing oxygen-transport metalloprotein that is present in the red blood cells of all vertebrates. In recent decades, there has been substantial interest in attempting to understand the structural basis and functional diversity of avian haemoglobins. Towards this end, purification, crystallization, preliminary X-ray diffraction and molecular-replacement studies have been carried out on cormorant (Phalacrocorax carbo) haemoglobin. Crystals were grown by the hanging-drop vapour-diffusion method using PEG 3350, NaCl and glycerol as precipitants. The crystals belonged to the trigonal system P3{sub 1}21, with unit-cell parameters a = b = 55.64, c = 153.38 Å, β = 120.00°; a complete data set was collected to a resolution of 3.5 Å. Matthews coefficient analysis indicated that the crystals contained a half-tetramer in the asymmetric unit.

  7. Effects of a diphenyl-ether herbicide, oxyfluorfen, on human BFU-E/CFU-E development and haemoglobin synthesis.

    Science.gov (United States)

    Rio, B; Parent-Massin, D; Lautraite, S; Hoellinger, H

    1997-02-01

    The diphenyl-ether herbicides exert their phytotoxic activity by preventing chlorophyll formation in plants as a result of inhibition of protoporphyrinogen oxidase. This enzyme is the last step of the common pathway for chlorophyll and haem biosynthesis. The aim of this work is to determine whether herbicide inhibitors of plant protoporphyrinogen oxidase could act on the human protoporphyrinogen oxidase involved in haemoglobin synthesis and cause heamatologic diseases. Human erythroblastic progenitors (BFU-E/CFU-E: Burst Forming Unit-Erythroid and Colony Forming Unit-Erythroid) were exposed to oxyfluorfen, a diphenyl-ether herbicide in the presence of erythropoietin, and the haematoxicity evaluated in vitro by scoring the development of BFU-E/CFU-E colonies after 7 and 14 days of culture. The toxic effect on differentiation has been evaluated using four criteria: morphology, total protein, total porphyrin, and haemoglobin content. The study of BFU-E/CFU-E proliferation and differentiation showed a cytotoxic effect of oxyfluorfen only at very high concentrations. In contrast, haemoglobin synthesis can be inhibited by concentration of oxyfluorfen (10(-4) M) that have no adverse effect on cellular proliferation.

  8. Impact of nutrition education on knowledge and haemoglobin status of hill women in Uttarakhand State of India.

    Science.gov (United States)

    Upadhyay, S; Kumar, A R; Raghuvanshi, R S; Singh, B B

    2011-12-01

    This study aimed to examine the impact of the use of single vs. combination of media on nutritional knowledge and haemoglobin status of women in a rural hill area in Uttarakhand State, India. Women from three villages were selected randomly and divided into three groups namely, print media group (n = 59), multimedia group (n = 53) and control group (n = 111). The print media group was exposed to nutrition education through the use of calendars on anaemia for 60 days; the multimedia group was given nutrition education through a combination of media including calendars, video films, and group discussions for 60 days. At pre-exposure stage, 62.7% of the women in the print media group, 67.9% of the multimedia group, and 66.7% of the control group had a low nutrition knowledge level. After exposure, the print media group and the multimedia group showed a significant rise in nutrition knowledge, with the multimedia group scoring significantly higher than the print media group. Overall, 69.1% of the women were anaemic with mean haemoglobin concentration of 10.74 +/- 0.86 g/dl. A non-significant rise in mean haemoglobin concentrations in the experimental groups was found at post-exposure stage. Calendars and video films are effective in increasing nutrition knowledge of illiterate hill women. Use of mass media programmes of longer duration should be encouraged to combat the nutritional problems of rural communities.

  9. RBC deformability and amino acid concentrations after hypo-osmotic challenge may reflect chronic cell hydration status in healthy young men

    Science.gov (United States)

    Stookey, Jodi D; Klein, Alexis; Hamer, Janice; Chi, Christine; Higa, Annie; Ng, Vivian; Arieff, Allen; Kuypers, Frans A; Larkin, Sandra; Perrier, Erica; Lang, Florian

    2013-01-01

    Biomarkers of chronic cell hydration status are needed to determine whether chronic hyperosmotic stress increases chronic disease risk in population-representative samples. In vitro, cells adapt to chronic hyperosmotic stress by upregulating protein breakdown to counter the osmotic gradient with higher intracellular amino acid concentrations. If cells are subsequently exposed to hypo-osmotic conditions, the adaptation results in excess cell swelling and/or efflux of free amino acids. This study explored whether increased red blood cell (RBC) swelling and/or plasma or urine amino acid concentrations after hypo-osmotic challenge might be informative about relative chronic hyperosmotic stress in free-living men. Five healthy men (20–25 years) with baseline total water intake below 2 L/day participated in an 8-week clinical study: four 2-week periods in a U-shaped A-B-C-A design. Intake of drinking water was increased by +0.8 ± 0.3 L/day in period 2, and +1.5 ± 0.3 L/day in period 3, and returned to baseline intake (0.4 ± 0.2 L/day) in period 4. Each week, fasting blood and urine were collected after a 750 mL bolus of drinking water, following overnight water restriction. The periods of higher water intake were associated with significant decreases in RBC deformability (index of cell swelling), plasma histidine, urine arginine, and urine glutamic acid. After 4 weeks of higher water intake, four out of five participants had ½ maximal RBC deformability below 400 mmol/kg; plasma histidine below 100 μmol/L; and/or undetectable urine arginine and urine glutamic acid concentrations. Work is warranted to pursue RBC deformability and amino acid concentrations after hypo-osmotic challenge as possible biomarkers of chronic cell hydration. PMID:24303184

  10. Phylogeny of the Juncaceae based on rbcL sequences, with special emphasis on Luzula DC. and Juncus L

    DEFF Research Database (Denmark)

    Drábková, L.; Kirschner, J.; Seberg, Ole

    2003-01-01

    Cladistic analysis of rbcL nucleotide sequences was applied to 58 taxa representing most subgenera and sections of Luzula and Juncus, chosen to reflect morphological and geographical diversity of both genera. Additionally, representatives of all other genera of the Juncaceae and two taxa from the......-supported clade is represented by an assemblage of representatives of five genera and species distributed in the Southern Hemisphere: Juncus capensis and J. lomatophyllus (both from section Graminifolii), Rostkovia, Distichia, Marsippospermum, and Patosia....

  11. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  12. A segment of rbcL gene as a potential tool for forensic discrimination of Cannabis sativa seized at Rio de Janeiro, Brazil.

    Science.gov (United States)

    Mello, I C T; Ribeiro, A S D; Dias, V H G; Silva, R; Sabino, B D; Garrido, R G; Seldin, L; de Moura Neto, Rodrigo Soares

    2016-03-01

    Cannabis sativa, known by the common name marijuana, is the psychoactive drug most widely distributed in the world. Identification of Cannabis cultivars may be useful for association to illegal crops, which may reveal trafficking routes and related criminal groups. This study provides evidence for the performance of a segment of the rbcL gene, through genetic signature, as a tool for identification for C. sativa samples apprehended by the Rio de Janeiro Police, Brazil. The PCR amplified and further sequenced the fragment of approximately 561 bp of 24 samples of C. sativa rbcL gene and showed the same nucleotide sequences, suggesting a possible genetic similarity or identical varieties. Comparing with other Cannabaceae family sequences, we have found 99% of similarity between the Rio de Janeiro sequence and three other C. sativa rbcL genes. These findings suggest that the fragment utilized at this study is efficient in identifying C. sativa samples, therefore, useful in genetic discrimination of samples seized in forensic cases.

  13. Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.

    Science.gov (United States)

    Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A

    2018-02-01

    Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.

  14. HAEMOGLOBIN LEVEL AS A RISK FACTOR FOR LOWER RESPIRATORY TRACT INFECTIONS

    Directory of Open Access Journals (Sweden)

    Harishchandra Venkata Yanamandala

    2017-06-01

    Full Text Available BACKGROUND Lower Respiratory Tract Infection (LRTI is an inflammation of the airways, pulmonary tissue below the larynx level. Children who are below 5 years of age suffer about 5-6 episodes of LRTI per year on an average. 1,2 The largest cause of death in children worldwide is pneumonia. If the haemoglobin level is below 11 g/dL 3 , then the child is considered as anaemic. In children, LRTIs associated with anaemia occur more commonly than in adults. Pneumonia kills about an estimated 1.1 million children under the age of 5 years old worldwide. It is more prevalent in South East Asia and Africa. 3,4,5 Anaemia is a condition in which the number of RBCs is very low to meet the body’s physiologic needs. The most common cause of anaemia is deficiency of iron. In both developing and developed countries, anaemia is a common health problem. This study is a prospective study, which was conducted to assess the low haemoglobin level as a risk factor for developing LRTI in children. MATERIALS AND METHODS This is a prospective study, which was conducted in 75 children who attended the outpatient unit of Department of Paediatrics, Gitam Institute of Medical Sciences and Research. It was conducted during the period between December 2015 to December 2016. By the symptoms and signs, pneumonia was diagnosed. Exclusion Criteria- Children who had congenital malformations of chest wall, severe systemic illness and protein malfunction. All children’s height and weight were recorded to assess the nutritional status. RESULTS C-Reactive Protein Estimation (CRP was more than 6 mg/L in 34 (45.3% patients in the study group, 11 (14.7% in the control group. Mantoux test was positive for 17 (22.6% among study group and none in the control group. Pneumonia as per radiological evidence was present in 49 (65.3% and hyperinflation of lungs in 26 (34.7% among the study group. X-ray reports were normal in 8 cases (10.7%. Age was not found to be a significant factor, which

  15. Effect of whey guava beverage supplementation on haemoglobin level of school going children

    Directory of Open Access Journals (Sweden)

    Divya .

    2014-12-01

    Full Text Available Introduction: Iron deficiency is estimated to affect one-half of the school going children in developing countries and school years are opportune time to intervene. Rationale: No coherent, co-ordinate and effective health services are available in the country for below 16 years. So attempt was made to know real scenario of iron deficiency. Objectives: To assess the effect of whey guava beverage supplementation on the haemoglobin level of school going children. Methodology:  An experimental research design was taken to conduct the study in which 200 children of 6≥and7≥ years in low socio economic status of both the genders were taken. For hemoglobin testing Sahil’s hemoglobinometer was used. Each child in experimental group was given 200ml of whey guava beverage for 90 days except holidays. Results and Discussion: The initial mean Hb levels of 6≥and7≥ year’s old boys and girls of control groups and experimental groups were ranging from 9.50 to 10.24 which were 79.17% to 85.33%. The results revealed that almost all the respondents were anaemic. After 90 days of feeding supplement the final mean Hb levels of 6≥7 years old boys and girls of control group  ranged from 10.10 to 10.65 which was 84.17% to 88.75%. Whereas in experimental group it ranged from 11.06 to 11.42 which were 91.92% to 95.17%. The study clearly evidences that the respondents in experimental group had improved with more Hb levels when compared to control group. Also children who were suffering from anaemia in experimental group became normal. Conclusion: Distribution of whey guava beverage through school feeding program may prove as an outstanding strategy to combat iron deficiency in school children.

  16. Haemoglobin-mediated response to hyper-thermal stress in the keystone species Daphnia magna.

    Science.gov (United States)

    Cuenca Cambronero, Maria; Zeis, Bettina; Orsini, Luisa

    2018-01-01

    Anthropogenic global warming has become a major geological and environmental force driving drastic changes in natural ecosystems. Due to the high thermal conductivity of water and the effects of temperature on metabolic processes, freshwater ecosystems are among the most impacted by these changes. The ability to tolerate changes in temperature may determine species long-term survival and fitness. Therefore, it is critical to identify coping mechanisms to thermal and hyper-thermal stress in aquatic organisms. A central regulatory element compensating for changes in oxygen supply and ambient temperature is the respiratory protein haemoglobin (Hb). Here, we quantify Hb plastic and evolutionary response in Daphnia magna subpopulations resurrected from the sedimentary archive of a lake with known history of increase in average temperature and recurrence of heat waves. By measuring constitutive changes in crude Hb protein content among subpopulations, we assessed evolution of the Hb gene family in response to temperature increase. To quantify the contribution of plasticity in the response of this gene family to hyper-thermal stress, we quantified changes in Hb content in all subpopulations under hyper-thermal stress as compared to nonstressful temperature. Further, we tested competitive abilities of genotypes as a function of their Hb content, constitutive and induced. We found that Hb-rich genotypes have superior competitive abilities as compared to Hb-poor genotypes under hyper-thermal stress after a period of acclimation. These findings suggest that whereas long-term adjustment to higher occurrence of heat waves may require a combination of plasticity and genetic adaptation, plasticity is most likely the coping mechanism to hyper-thermal stress in the short term. Our study suggests that with higher occurrence of heat waves, Hb-rich genotypes may be favoured with potential long-term impact on population genetic diversity.

  17. Glycated haemoglobin (HbA1c), diabetes and trajectories of change in episodic memory performance.

    Science.gov (United States)

    Pappas, Colleen; Andel, Ross; Infurna, Frank J; Seetharaman, Shyam

    2017-02-01

    As the ageing population grows, it is important to identify strategies to moderate cognitive ageing. We examined glycated haemoglobin (HbA1c) and diabetes in relation to level and change in episodic memory in older adults with and without diabetes. Data from 4419 older adults with (n=950) and without (n=3469) diabetes participating in a nationally representative longitudinal panel study (the Health and Retirement Study) were examined. Average baseline age was 72.66 years and 58% were women. HbA1c was measured in 2006 and episodic memory was measured using immediate and delayed list recall over 4 biennial waves between 2006 and 2012. Growth curve models were used to assess trajectories of episodic memory change. In growth curve models adjusted for age, sex, education, race, depressive symptoms and waist circumference, higher HbA1c levels and having diabetes were associated with poorer baseline episodic memory (p=0.036 and HbA1c on episodic memory decline was smaller than the effect of age. The results were stronger for women than men and were not modified by age or race. When the main analyses were estimated for those with and without diabetes separately, HbA1c was significantly linked to change in episodic memory only among those with diabetes. Higher HbA1c and diabetes were both associated with declines in episodic memory, with this relationship further exacerbated by having diabetes and elevated HbA1c. HbA1c appeared more important for episodic memory performance among women than men. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Year-to-year variability in haemoglobin mass response to two altitude training camps.

    Science.gov (United States)

    McLean, Blake D; Buttifant, David; Gore, Christopher J; White, Kevin; Kemp, Justin

    2013-12-01

    To quantify the year-to-year variability of altitude-induced changes in haemoglobin mass (Hb(mass)) in elite team-sport athletes. 12 Australian-Footballers completed a 19-day (ALT1) and 18-day (ALT2) moderate altitude (∼2100 m), training camp separated by 12 months. An additional 20 participants completed only one of the two training camps (ALT1 additional n=9, ALT2 additional n=11). Total Hb(mass) was assessed using carbon monoxide rebreathing before (PRE), after (POST₁) and 4 weeks after each camp. The typical error of Hb(mass) for the pooled data of all 32 participants was 2.6%. A contemporary statistics analysis was used with the smallest worthwhile change set to 2% for Hb(mass). POST₁ Hb(mass) was very likely increased in ALT1 (3.6 ± 1.6%, n=19; mean ± ∼90 CL) as well as ALT2 (4.4 ± 1.3%, n=23) with an individual responsiveness of 1.3% and 2.2%, respectively. There was a small correlation between ALT1 and ALT2 (R=0.21, p=0.59) for a change in Hb(mass), but a moderately inverse relationship between the change in Hb(mass) and initial relative Hb(mass) (g/kg (R=-0.51, p=0.04)). Two preseason moderate altitude camps 1 year apart yielded a similar (4%) mean increase in Hb(mass) of elite footballers, with an individual responsiveness of approximately half the group mean effect, indicating that most players gained benefit. Nevertheless, the same individuals generally did not change their Hb(mass) consistently from year to year. Thus, a 'responder' or 'non-responder' to altitude for Hb(mass) does not appear to be a fixed trait.

  19. Metabolic and Cardiovascular Ageing Indices in Relation to Glycated Haemoglobin in Healthy and Diabetic Subjects.

    Science.gov (United States)

    Suvarna H I, Shruthi; Moodithaya, Shailaja; Sharma, Raghava

    2017-01-01

    Ageing is a natural phenomenon that has tremendous amount of control over normal physiological functions. Diabetes mellitus and ageing share common symptoms like stiffness and loss of functioning of tissues due to cross-liked proteins and free radicals. Glycated Haemoglobin (HbA1c) is often used as a stable cumulative index of glycemic control and has shown that even in non-diabetic adults, there is a steady increase in HbA1c levels with age. Aim of the study is to evaluate the strength of association of HbA1c with metabolic and cardiovascular ageing indices in subjects between the age group of 40 to 60 yrs. A total of 220 subjects, with (n=110) and without (n=110) diabetes were assessed for the metabolic and cardiovascular ageing indices. BMI, waist hip ratio, fat percentage, Fasting blood sugar and HbA1c were assessed as metabolic ageing indices. The cardiovascular ageing indices measured were resting heart rate, blood pressure and heart rate variability. Ageing indices were compared between subjects with and without diabetes using independent' t' test and showed that the T2DM group exhibit significant accelerated ageing as compared to that of the controls. Pearson's and partial correlation coefficient was used to assess the association of HbA1c with the ageing indices without and with controlling for chronological age, indicated that, strength of association of levels of HBA1c with cardiovascular and other metabolic indices of ageing is statistically significant. The study concludes that the tightness of glycemic control has a significant impact on the biological ageing process. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  20. Tubal origin of ovarian cancer - the double-edged sword of haemoglobin.

    Science.gov (United States)

    Lin, Shiou-Fu; Gerry, Emily; Shih, Ie-Ming

    2017-05-01

    Ovarian high-grade serous carcinoma (HGSC) is the most malignant neoplasm of the gynaecological tract. While the origins of many human malignant neoplasms are clear, the origin of HGSC remains poorly understood. This lack of knowledge limits our understanding of its pathogenesis and compromises efforts devoted to developing better early detection tools and effective preventative interventions. The paradigm of the tubal origin of HGSC has been advanced since the initial report of dysplastic lesions (now known as serous tubal intraepithelial carcinomas or STICs) that morphologically resemble HGSC in the Fallopian tube. These were observed in a group of patients with a genetic predisposition to ovarian cancer who were undergoing risk-reducing salpingo-oophorectomy. Since then, a series of clinico-pathological and molecular studies have characterized STICs and their concurrent HGSCs, and the results support the new paradigm of a tubal origin of many 'ovarian' HGSCs. Reactive oxygen species-containing ovulatory follicular fluid has been thought to be the major culprit behind DNA damage in tubal epithelial cells, leading to either cell death or, if the cells survive, mutagenesis. A recent report from this journal demonstrates that ferryl haemoglobin (Hb) in peritoneal fluid could prevent cell death from DNA-damaged fimbrial epithelial cells, facilitating ovulation-induced carcinogenesis of tubal epithelium. This timely study provides new insight into the tumour initiation event in HGSC. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  1. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  2. Behaviour of perioperative values of haemoglobin, haematocrit and red blood cells in elderly patients undergoing lower limb arthroplasty: a retrospective cohort study on non-transfused patients.

    Science.gov (United States)

    Drago, L; De Vecchi, E; Romano', C L; Vassena, C; Banfi, G

    2013-01-01

    Little is known on how elderly patients recover pre-operative haemoglobin, haematocrit and red blood cell levels after total hip and knee arthroplasties. In this study we aimed to evaluate blood loss and recovery blood levels in relation to gender, type of surgery and preoperative haemoglobin values. We conducted a retrospective cohort study on 187 patients over 65 years of age who underwent total knee or total hip arthroplasty between January 2008 and December 2009. Preoperative blood analysis was carried out within 40 days prior to intervention followed by a 15-day postoperative follow-up. Haemoglobin recovery values in anaemic patients versus healthy patients was also estimated. All tested values decreased significantly during the first 3-5 postoperative days. Haemoglobin levels decreased statistically significantly more in males than in females, while no significant differences were observed for haematocrit and erythrocytes. Recovery of haemoglobin values did not differ significantly between healthy patients and patients with preoperative haemoglobin below 120 g/L. Furthermore, our data showed a higher blood loss in total hip arthroplasty, whilst recovery rates showed to be higher after a total knee arthroplasty procedure. In conclusion, the type of intervention and gender played an important role in blood loss and recovery rates in total joint arthroplasty.

  3. Reconstructing a herbivore’s diet using a novel rbcL DNA mini-barcode for plants

    Science.gov (United States)

    Erickson, David L.; Reed, Elizabeth; Ramachandran, Padmini; Bourg, Norman; McShea, William J.; Ottesen, Andrea

    2017-01-01

    Next Generation Sequencing and the application of metagenomic analyses can be used to answer questions about animal diet choice and study the consequences of selective foraging by herbivores. The quantification of herbivore diet choice with respect to native versus exotic plant species is particularly relevant given concerns of invasive species establishment and their effects on ecosystems. While increased abundance of white-tailed deer (Odocoileus virginianus) appears to correlate with increased incidence of invasive plant species, data supporting a causal link is scarce. We used a metabarcoding approach (PCR amplicons of the plant rbcL gene) to survey the diet of white-tailed deer (fecal samples), from a forested site in Warren County, Virginia with a comprehensive plant species inventory and corresponding reference collection of plant barcode and chloroplast sequences. We sampled fecal pellet piles and extracted DNA from 12 individual deer in October 2014. These samples were compared to a reference DNA library of plant species collected within the study area. For 72 % of the amplicons, we were able to assign taxonomy at the species level, which provides for the first time—sufficient taxonomic resolution to quantify the relative frequency at which native and exotic plant species are being consumed by white-tailed deer. For each of the 12 individual deer we collected three subsamples from the same fecal sample, resulting in sequencing 36 total samples. Using Qiime, we quantified the plant DNA found in all 36 samples, and found that variance within samples was less than variance between samples (F = 1.73, P = 0.004), indicating additional subsamples may not be necessary. Species level diversity ranged from 60 to 93 OTUs per individual and nearly 70 % of all plant sequences recovered were from native plant species. The number of species detected did reduce significantly (range 4–12) when we excluded species whose OTU composed <1 % of each

  4. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  5. [Complete blood count reference values of donated cord blood from Korean neonates].

    Science.gov (United States)

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Kim, Byoung Jae; Hwang, Kyu Ri; Kim, Jin Ju; Roh, Eun Youn

    2009-06-01

    In the public cord blood (CB) banks, only safe CB units with adequate cell doses are processed and stored. Complete blood count (CBC) of CB is crucial for estimating total nucleated cells (TNC) and screening suitable CB units without hematologic abnormalities. We analyzed CBC parameters of the donated CB from healthy Korean neonates to establish CBC reference values. A total of 2,129 Korean CB units, donated and processed during the period from August 2007 to December 2007, were enrolled. We measured hemoglobin (Hb), white blood cell (WBC) count, differential count of WBC, platelets and nucleated red blood cell (nRBC) count by XE-2100 automated hematology analyzer (Sysmex, Japan), and estimated reference value of each parameter by using parametric (Mean+/-2SD) and/or non-parametric methods (2.5-97.5 percentile). And also, we compared the result of each parameter in relation to sex of neonates and delivery method. Because the differences of CBC values among different subgroups were not remarkable, we established the reference intervals as follows without subgroup division: Hb, 9.0-14.4 g/dL; WBC count, 5.6-18.5 x 10(3)/microL; differential count of WBC (neutrophils, 40.8-72.4%; lymphocytes, 17.2-46.7%; monocytes, 4.9-12.8%; eosinophils, 0.7-7.0%; basophils, 0.0-1.6%); platelet, 130-287 x 10(3)/microL; nRBCs, 0.0-13.1/100 WBC. We established cord blood CBC reference values of healthy Korean neonates using a large-scale CB units. The established CBC reference values from our study will be useful as basic data for CBC interpretation and assessment of transplant suitability of donated CB.

  6. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  7. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  8. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  9. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  10. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  11. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  12. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  13. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  14. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  15. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  16. Data analytics identify glycated haemoglobin co-markers for type 2 diabetes mellitus diagnosis.

    Science.gov (United States)

    Jelinek, Herbert F; Stranieri, Andrew; Yatsko, Andrew; Venkatraman, Sitalakshmi

    2016-08-01

    Glycated haemoglobin (HbA1c) is being more commonly used as an alternative test for the identification of type 2 diabetes mellitus (T2DM) or to add to fasting blood glucose level and oral glucose tolerance test results, because it is easily obtained using point-of-care technology and represents long-term blood sugar levels. HbA1c cut-off values of 6.5% or above have been recommended for clinical use based on the presence of diabetic comorbidities from population studies. However, outcomes of large trials with a HbA1c of 6.5% as a cut-off have been inconsistent for a diagnosis of T2DM. This suggests that a HbA1c cut-off of 6.5% as a single marker may not be sensitive enough or be too simple and miss individuals at risk or with already overt, undiagnosed diabetes. In this study, data mining algorithms have been applied on a large clinical dataset to identify an optimal cut-off value for HbA1c and to identify whether additional biomarkers can be used together with HbA1c to enhance diagnostic accuracy of T2DM. T2DM classification accuracy increased if 8-hydroxy-2-deoxyguanosine (8-OhdG), an oxidative stress marker, was included in the algorithm from 78.71% for HbA1c at 6.5% to 86.64%. A similar result was obtained when interleukin-6 (IL-6) was included (accuracy=85.63%) but with a lower optimal HbA1c range between 5.73 and 6.22%. The application of data analytics to medical records from the Diabetes Screening programme demonstrates that data analytics, combined with large clinical datasets can be used to identify clinically appropriate cut-off values and identify novel biomarkers that when included improve the accuracy of T2DM diagnosis even when HbA1c levels are below or equal to the current cut-off of 6.5%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Root Effect Haemoglobins in Fish May Greatly Enhance General Oxygen Delivery Relative to Other Vertebrates.

    Directory of Open Access Journals (Sweden)

    Jodie L Rummer

    Full Text Available The teleost fishes represent over half of all extant vertebrates; they occupy nearly every body of water and in doing so, occupy a diverse array of environmental conditions. We propose that their success is related to a unique oxygen (O2 transport system involving their extremely pH-sensitive haemoglobin (Hb. A reduction in pH reduces both Hb-O2 affinity (Bohr effect and carrying capacity (Root effect. This, combined with a large arterial-venous pH change (ΔpHa-v relative to other vertebrates, may greatly enhance tissue oxygen delivery in teleosts (e.g., rainbow trout during stress, beyond that in mammals (e.g., human. We generated oxygen equilibrium curves (OECs at five different CO2 tensions for rainbow trout and determined that, when Hb-O2 saturation is 50% or greater, the change in oxygen partial pressure (ΔPO2 associated with ΔpHa-v can exceed that of the mammalian Bohr effect by at least 3-fold, but as much as 21-fold. Using known ΔpHa-v and assuming a constant arterial-venous PO2 difference (Pa-vO2, Root effect Hbs can enhance O2 release to the tissues by 73.5% in trout; whereas, the Bohr effect alone is responsible for enhancing O2 release by only 1.3% in humans. Disequilibrium states are likely operational in teleosts in vivo, and therefore the ΔpHa-v, and thus enhancement of O2 delivery, could be even larger. Modeling with known Pa-vO2 in fish during exercise and hypoxia indicates that O2 release from the Hb and therefore potentially tissue O2 delivery may double during exercise and triple during some levels of hypoxia. These characteristics may be central to performance of athletic fish species such as salmonids, but may indicate that general tissue oxygen delivery may have been the incipient function of Root effect Hbs in fish, a trait strongly associated with the adaptive radiation of teleosts.

  18. The Effect of Date (Phoenix dactylifera Juice on Haemoglobin Level An Experimental Study in Iron Supplemented Rats

    Directory of Open Access Journals (Sweden)

    Ady Try Himawan Zen

    2013-06-01

    Full Text Available There has been more research on the iron supplementation. Date juice has been shown to be rich in iron. It has been reported to increase the hemoglobin level in rats. Few studies has been conducted on the effect of date juice on the hemoglobin level in male white Wistar rats fed low iron diet.This research was conducted to evaluate the effect of (Phoenix dactylifera juice on haemoglobin level in iron supplemented rats. In this experimental study using post test control group design, 24 male white Wistar rats were divided into 4 groups. G-I served as the control group (standard diet and aquadest. G II was given the low Fe diet and aquadest for 21 d. G-III,IV were given the low fe diet and aquadest plus date juice at the concentration of 50%, 100% respectively. The treatment was given for 14 days. Spectrophotometer was used to assess the haemoglobin level of rats. One way anova followed by Post Hoc LSD was applied for the data analysis. Mean of hemoglobin (g/dl level for the four groups were 12,03, 7.72, 9.25, 10.35 respectively. Test resulted in p<0.05. Post Hoc LSD test resulted in a significant different between K-I and G-II, G-III, G-IV ;G-II and G-III, G-IV ;G-III and G-IV. In conclusion, date juice increases the haemoglobin level in male white rats fed on the low fe diet.

  19. Novel haemoglobin-derived antimicrobial peptides from chicken (Gallus gallus) blood: purification, structural aspects and biological activity.

    Science.gov (United States)

    Vasilchenko, A S; Rogozhin, E A; Vasilchenko, A V; Kartashova, O L; Sycheva, M V

    2016-12-01

    To purify and characterize antimicrobial peptides derived from the acid extract of Gallus gallus blood cells. Two polypeptides (i.e. CHb-1 and CHb-2) with antibacterial activity were detected in the acidic extract of blood cells from chicken (G. gallus). The isolated peptides that possessed a potent antibacterial activity were purified using a two-step chromatography procedure that involved solid-phase extraction of a total protein/peptide extract followed by thin fractionation by reversed-phase high performance liquid chromatography (RP-HPLC). The molecular masses of the purified peptides were similar and were 4824·4 and 4825·2 Da, which have been measured by matrix-assisted laser desorption/ionization mass spectrometry (MALDI TOF MS). Their amino acid sequences were determined by Edman degradation and showed that the peptides were fully identical to the two fragments of G. gallus α-haemoglobin localized into different subunits (A and D respectively). The peptides were active in micromolar concentrations against Gram-negative Escherichia coli K12 TG1. Using the 1-N-phenylnaphthylamine, the FITC-dextran labelled probes and the live/dead staining allowed to show the hemocidin mode of action and estimate the pore size. In this study, for the first time, α-haemoglobin from chicken (G. gallus) has been investigated as a donor of the two high homologous native peptide fragments that possess potent antibacterial activity in vitro. These are membrane-active peptides and their mechanism of action against E. coli involves a toroidal pore formation. The obtained results expand the perception of the role of haemoglobin in a living system, describing it as a source of multifunction substances. Additionally, the data presented in this paper may contribute to the development of new, cost-effective, antimicrobial agents. © 2016 The Society for Applied Microbiology.

  20. Effects of prolonged compression on the variations of haemoglobin oxygenation-assessment by spectral analysis of reflectance spectrophotometry signals

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zengyong; Tam, Eric W C; Mak, Arthur F T; Lau, Roy Y C [Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong (China)

    2006-11-07

    The consequences of rhythmical flow motion for nutrition and the oxygen supply to tissue are largely unknown. In this study, the periodic variations of haemoglobin oxygenation in compressed and uncompressed skin were evaluated with a reflection spectrometer using an in vivo Sprague-Dawley rat model. Skin compression was induced over the trochanter area by a locally applied external pressure of 13.3 kPa (100 mmHg) via a specifically designed pneumatic indentor. A total of 19 rats were used in this study. The loading duration is 6 h per day for four consecutive days. Haemoglobin oxygenation variations were quantified using spectral analysis based on wavelets' transformation. The results found that in both compressed and uncompressed skin, periodic variations of the haemoglobin oxygenation were characterized by two frequencies in the range of 0.01-0.05 Hz and 0.15-0.4 Hz. These frequency ranges coincide with those of the frequency range of the endothelial-related metabolic and myogenic activities found in the flow motion respectively. Tissue compression following the above loading schedule induced a significant decrease in the spectral amplitudes of frequency interval 0.01-0.05 Hz during the pre-occlusion period on day 3 and day 4 as compared to that on day 1 (p < 0.05). In contrast, at a frequency range of 0.15-0.4 Hz, prolonged compression caused a significant increase in spectral amplitude during the pre-occlusion period in the compressed tissue on day 3 (p = 0.041) and day 4 (p = 0.024) compared to that in the uncompressed tissue on day 1. These suggested that the variations of the haemoglobin oxygenation were closely related to the endothelial-related metabolic and myogenic activities. Increased amplitude in the frequency interval 0.15-0.4 Hz indicated an increased workload of the vascular smooth muscle and could be attributed to the increase of O{sub 2} consumption rates of arteriolar walls. The modification of vessel wall oxygen consumption might

  1. A two-locus global DNA barcode for land plants: the coding rbcL gene complements the non-coding trnH-psbA spacer region.

    Science.gov (United States)

    Kress, W John; Erickson, David L

    2007-06-06

    A useful DNA barcode requires sufficient sequence variation to distinguish between species and ease of application across a broad range of taxa. Discovery of a DNA barcode for land plants has been limited by intrinsically lower rates of sequence evolution in plant genomes than that observed in animals. This low rate has complicated the trade-off in finding a locus that is universal and readily sequenced and has sufficiently high sequence divergence at the species-level. Here, a global plant DNA barcode system is evaluated by comparing universal application and degree of sequence divergence for nine putative barcode loci, including coding and non-coding regions, singly and in pairs across a phylogenetically diverse set of 48 genera (two species per genus). No single locus could discriminate among species in a pair in more than 79% of genera, whereas discrimination increased to nearly 88% when the non-coding trnH-psbA spacer was paired with one of three coding loci, including rbcL. In silico trials were conducted in which DNA sequences from GenBank were used to further evaluate the discriminatory power of a subset of these loci. These trials supported the earlier observation that trnH-psbA coupled with rbcL can correctly identify and discriminate among related species. A combination of the non-coding trnH-psbA spacer region and a portion of the coding rbcL gene is recommended as a two-locus global land plant barcode that provides the necessary universality and species discrimination.

  2. The influence of irradiation potential on the degree of conversion and mechanical properties of two bulk-fill flowable RBC base materials.

    Science.gov (United States)

    Finan, Leah; Palin, William M; Moskwa, Natalia; McGinley, Emma Louise; Fleming, Garry J P

    2013-08-01

    To assess the depth of cure claims of two bulk-fill flowable RBC bases (SDR and x-tra base) using Fourier transform infrared (FTIR) spectroscopy, biaxial flexure strength (BFS), and Vickers hardness number (VHN) for specimen depths of 8mm (in 1mm increments). The degree of conversion (DC) was measured by monitoring the peak height (6164cm(-1)) of specimens (11.0±0.1mm diameter, 1.0±0.1mm thickness) during light irradiation for 20s using a quartz tungsten halogen light curing unit at 650±26mW/cm(2). DC was measured up to 120s post irradiation and repeated (n=3) for irradiation depths up to 8mm (in 1mm increments). Further series (n=20) of eight discs were prepared, stacked, light irradiated and numbered from one to eight (distance from the LCU). The specimens were stored at 37±1°C for 24h and BFS tested with the fracture fragments used to determine the VHN for each specimen. X-tra base can be irradiated to 8mm without a change in DC, something the SDR material cannot claim. However, the DC results confirm both bulk-fill flowable RBC bases have a depth of cure in excess of 4mm. One-way ANOVAs of BFS and VHN data showed significant differences between irradiation depths for x-tra base and SDR with increasing irradiation depth (4mm) resulting in significant reductions in mean BFS and VHN. The claims that the bulk-fill flowable RBC bases have a depth of cure in excess of 4mm can be confirmed but the differing chemistry of the resin formulations and filler characteristics contribute to significant differences in DC, BFS and VHN data between the two materials tested. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia; Measurement of cerebral blood volume (CBV) with sup 99m Tc-RBC SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo (Hokkaido Neurosurgical Memorial Hospital (Japan)); Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi

    1990-03-01

    To evaluate the efficacy of tests for selecting patients with hemodynamic compromise, measurement of cerebral blood volume (CBV) with {sup 99m}Tc-RBC single photon emission computed tomography (SPECT) was performed in thirteen patients with occlusive cerebrovascular disease, and was compared with results obtained by {sup 133}Xe SPECT and acetazolamide (Diamox) test. All patients in our study suffered TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery, although plain CT scan or MRI revealed no or, if any, only localized infarcted lesions. Regional cerebral blood volume (rCBV) was measured with {sup 99m}Tc-RBC SPECT and regional cerebral blood flow (rCBF) was measured with {sup 133}Xe SPECT before and after intravenous injection of 10 - 12 mg/kg acetazolamide (Diamox). Our results suggest that the ipsilateral rCBV/rCBF (mean transit time) is a more sensitive index of the cerebral perfusion reserve than the use of only rCBV or rCBF of the ipsilateral hemisphere. Also, the ipsilateral rCBV/rCBF is significantly correlated (r= -0.72) with the Diamox reactivity of rCBF, which is considered to represent the cerebral vasodilatory capacity in patients with chronic cerebral ischemia. Postoperative SPECT study revealed remarkable improvement of ipsilateral rCBV/rCBF and Diamox reactivity in four patients who underwent EC/IC bypass surgery to improve the hemodynamic compromise. In conclusion, our results suggest that the measurement of rCBV/rCBF with {sup 133}Xe SPECT and {sup 99m}Tc-RBC SPECT is useful for detecting the hemodynamic compromise in patients with occlusive cerebrovascular disease. (author).

  4. Increased microerythrocyte count in homozygous alpha(+-thalassaemia contributes to protection against severe malarial anaemia.

    Directory of Open Access Journals (Sweden)

    Freya J I Fowkes

    2008-03-01

    Full Text Available The heritable haemoglobinopathy alpha(+-thalassaemia is caused by the reduced synthesis of alpha-globin chains that form part of normal adult haemoglobin (Hb. Individuals homozygous for alpha(+-thalassaemia have microcytosis and an increased erythrocyte count. Alpha(+-thalassaemia homozygosity confers considerable protection against severe malaria, including severe malarial anaemia (SMA (Hb concentration 1.1 x 10(12/l as a result of the reduced mean cell Hb in homozygous alpha(+-thalassaemia. In addition, children homozygous for alpha(+-thalassaemia require a 10% greater reduction in erythrocyte count than children of normal genotype (p = 0.02 for Hb concentration to fall to 50 g/l, the cutoff for SMA. We estimated that the haematological profile in children homozygous for alpha(+-thalassaemia reduces the risk of SMA during acute malaria compared to children of normal genotype (relative risk 0.52; 95% confidence interval [CI] 0.24-1.12, p = 0.09.The increased erythrocyte count and microcytosis in children homozygous for alpha(+-thalassaemia may contribute substantially to their protection against SMA. A lower concentration of Hb per erythrocyte and a larger population of erythrocytes may be a biologically advantageous strategy against the significant reduction in erythrocyte count that occurs during acute infection with the malaria parasite Plasmodium falciparum. This haematological profile may reduce the risk of anaemia by other Plasmodium species, as well as other causes of anaemia. Other host polymorphisms that induce an increased erythrocyte count and microcytosis may confer a similar advantage.

  5. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  6. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  7. Card counting in continuous time

    OpenAIRE

    Andersson, Patrik

    2012-01-01

    We consider the problem of finding an optimal betting strategy for a house-banked casino card game that is played for several coups before reshuffling. The sampling without replacement makes it possible to take advantage of the changes in the expected value as the deck is depleted, making large bets when the game is advantageous. Using such a strategy, which is easy to implement, is known as card counting. We consider the case of a large number of decks, making an approximat...

  8. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  9. Haemoglobin mass and running time trial performance after recombinant human erythropoietin administration in trained men.

    Directory of Open Access Journals (Sweden)

    Jérôme Durussel

    Full Text Available UNLABELLED: Recombinant human erythropoietin (rHuEpo increases haemoglobin mass (Hb(mass and maximal oxygen uptake (v O(2 max. PURPOSE: This study defined the time course of changes in Hb(mass, v O(2 max as well as running time trial performance following 4 weeks of rHuEpo administration to determine whether the laboratory observations would translate into actual improvements in running performance in the field. METHODS: 19 trained men received rHuEpo injections of 50 IU•kg(-1 body mass every two days for 4 weeks. Hb(mass was determined weekly using the optimized carbon monoxide rebreathing method until 4 weeks after administration. v O(2 max and 3,000 m time trial performance were measured pre, post administration and at the end of the study. RESULTS: Relative to baseline, running performance significantly improved by ∼6% after administration (10:30±1:07 min:sec vs. 11:08±1:15 min:sec, p<0.001 and remained significantly enhanced by ∼3% 4 weeks after administration (10:46±1:13 min:sec, p<0.001, while v O(2 max was also significantly increased post administration (60.7±5.8 mL•min(-1•kg(-1 vs. 56.0±6.2 mL•min(-1•kg(-1, p<0.001 and remained significantly increased 4 weeks after rHuEpo (58.0±5.6 mL•min(-1•kg(-1, p = 0.021. Hb(mass was significantly increased at the end of administration compared to baseline (15.2±1.5 g•kg(-1 vs. 12.7±1.2 g•kg(-1, p<0.001. The rate of decrease in Hb(mass toward baseline values post rHuEpo was similar to that of the increase during administration (-0.53 g•kg(-1•wk(-1, 95% confidence interval (CI (-0.68, -0.38 vs. 0.54 g•kg(-1•wk(-1, CI (0.46, 0.63 but Hb(mass was still significantly elevated 4 weeks after administration compared to baseline (13.7±1.1 g•kg(-1, p<0.001. CONCLUSION: Running performance was improved following 4 weeks of rHuEpo and remained elevated 4 weeks after administration compared to baseline. These field performance effects coincided with r

  10. Soluble CD163, a product of monocyte/macrophage activation, is inversely associated with haemoglobin levels in placental malaria.

    Directory of Open Access Journals (Sweden)

    Caroline Lin Lin Chua

    Full Text Available In Plasmodium falciparum malaria, activation of monocytes and macrophages (monocytes/macrophages can result in the production of various inflammatory mediators that contribute to immunopathology. Soluble CD163 (sCD163 is a specific marker of monocyte/macrophage activation typically found at increased levels during various inflammatory conditions and can be associated with poor clinical outcomes. To better understand the relationships between levels of sCD163 and clinical parameters in women with placental malaria, we measured plasma sCD163 levels in maternal peripheral and placental blood compartments at delivery and determined their correlations with birth weight and maternal haemoglobin concentrations. sCD163 levels were negatively correlated with birth weight only in the placental compartment (r = -0.145, p = 0.03 and were inversely correlated with maternal haemoglobin concentrations, both in peripheral blood (r = -0.238, p = 0.0004 and in placental blood (r = -0.259, p = 0.0001. These inverse relationships suggest a potential role for monocyte/macrophage activation in the pathogenesis of malaria in pregnancy, particularly in relation to malaria-associated anaemia.

  11. Structural and Functional Characterization of a New Double Variant Haemoglobin (HbG-Philadelphia/Duarte α(2)β(2)).

    Science.gov (United States)

    Fais, Antonella; Casu, Mariano; Ruggerone, Paolo; Ceccarelli, Matteo; Porcu, Simona; Era, Benedetta; Anedda, Roberto; Sollaino, Maria Carla; Galanello, Renzo; Corda, Marcella

    2011-01-01

    WE REPORT THE FIRST CASE OF COSEGREGATION OF TWO HAEMOGLOBINS (HBS): HbG-Philadelphia [α68(E17)Asn → Lys] and HbDuarte [β62(E6)Ala → Pro]. The proband is a young patient heterozygous also for β°-thalassaemia. We detected exclusively two haemoglobin variants: HbDuarte and HbG-Philadelphia/Duarte. Functional study of the new double variant HbG-Philadelphia/Duarte exhibited an increase in oxygen affinity, with a slight decrease of cooperativity and Bohr effect. This functional behaviour is attributed to β62Ala → Pro instead of α68Asn → Lys substitution. Indeed, HbG-Philadelphia isolated in our laboratory from blood cells donor carrier for this variant is not affected by any functional modification, whereas purified Hb Duarte showed functional properties very similar to the double variant. NMR and MD simulation studies confirmed that the presence of Pro instead of Ala at the β62 position produces displacement of the E helix and modifications of the tertiary structure. The substitution α68(E17)Asn → Lys does not cause significant structural and dynamical modifications of the protein. A possible structure-based rational of substitution effects is suggested.

  12. Influence of iron deficiency in the radiopharmaceutical behavior of red blood cells labeled with 99mTc(99mTC-RBC)

    International Nuclear Information System (INIS)

    Calmanovici, G.; Salgueiro, M.J.; Pernas, L.; Collia, N.; Leonardi, N.; Zubillaga, M.

    2005-01-01

    Full text: Red blood cells (RBCs) labeled with 99m Tc are commonly used in the evaluation of cardiac function, gastrointestinal tract bleeding, red blood cell volume or splenic sequestration. Generally stannous ion is used as reducing agent. A proposed mechanism is that once the stannous ion (Sn) and the pertechnetate ( 99m Tc) reach the interior of the RBC, the radionuclide is mainly house in the β-chain of hemoglobin. The aim of this study was to determine if hemoglobin content reduction, an indicator of iron deficiency anemia, could affect the efficiency of RBC labeling and the biological distribution of this radiopharmaceutical. We studied 30 rats fed for 3 weeks after weaning with diets with iron contents of 6.5 ppm (group A), 18 ppm (group B) and 100 ppm (control). For all groups, the labeling yields were always higher than 97%; the percentage of radioactivity was mostly founded in blood with almost negligible radioactivity the rest of the studied organs. We can conclude that the decrease in hemoglobin content, an indicator of iron deficiency anemia, does not interfere neither in the labeling nor in the biodistribution of red blood cells labeled with 99m Tc. (author)

  13. Implications of resin-based composite (RBC) restoration on cuspal deflection and microleakage score in molar teeth: Placement protocol and restorative material.

    Science.gov (United States)

    McHugh, Lauren E J; Politi, Ioanna; Al-Fodeh, Rami S; Fleming, Garry J P

    2017-09-01

    To assess the cuspal deflection of standardised large mesio-occluso-distal (MOD) cavities in third molar teeth restored using conventional resin-based composite (RBC) or their bulk fill restorative counterparts compared with the unbound condition using a twin channel deflection measuring gauge. Following thermocycling, the cervical microleakage of the restored teeth was assessed to determine marginal integrity. Standardised MOD cavities were prepared in forty-eight sound third molar teeth and randomly allocated to six groups. Restorations were placed in conjunction with (and without) a universal bonding system and resin restorative materials were irradiated with a light-emitting-diode light-curing-unit. The dependent variable was the restoration protocol, eight oblique increments for conventional RBCs or two horizontal increments for the bulk fill resin restoratives. The cumulative buccal and palatal cuspal deflections from a twin channel deflection measuring gauge were summed, the restored teeth thermally fatigued, immersed in 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage score. The one-way analysis of variance (ANOVA) identified third molar teeth restored using conventional RBC materials had significantly higher mean total cuspal deflection values compared with bulk fill resin restorative restoration (all pmaterial selection is vital in the absence of clinical data. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Ulva and Enteromorpha (Ulvaceae, Chlorophyta) from two sides of the Yellow Sea: analysis of nuclear rDNA ITS and plastid rbcL sequence data

    Science.gov (United States)

    Wang, Jinfeng; Li, Nan; Jiang, Peng; Boo, Sung Min; Lee, Wook Jae; Cui, Yulin; Lin, Hanzhi; Zhao, Jin; Liu, Zhengyi; Qin, Song

    2010-07-01

    Ulvacean green seaweeds are common worldwide; they formed massive green tides in the Yellow Sea in recent years, which caused marine ecological problems as well as a social issue. We investigated two major genera of the Ulvaceae, Ulva and Enteromorpha, and collected the plastid rbcL and nuclear ITS sequences of specimens of the genera in two sides of the Yellow Sea and analyzed them. Phylogenetic trees of rbcL data show the occurrence of five species of Enteromorpha ( E. compressa, E. flexuosa, E. intestinalis, E. linza and E. prolifera) and three species of Ulva ( U. pertusa, U. rigida and U. ohnoi). However, we found U. ohnoi, which is known as a subtropical to tropical species, at two sites on Jeju Island, Korea. Four ribotypes in partial sequences of 5.8S rDNA and ITS2 from E. compressa were also found. Ribotype network analysis revealed that the common ribotype, occurring in China, Korea and Europe, is connected with ribotypes from Europe and China/Japan. Although samples of the same species were collected from both sides of the Yellow Sea, intraspecific genetic polymorphism of each species was low among samples collected worldwide.

  15. Common antigenic determinants of haemoglobin as basis of immunological cross-reactivity between chironomid species (Diptera, Chironomidae): studies with human and animal sera.

    Science.gov (United States)

    Baur, X; Dewair, M; Haegele, K; Prelicz, H; Scholl, A; Tichy, H

    1983-01-01

    Chironomids, of which approximately 10,000 species exist, are reported to cause severe immediate type allergic diseases in man. In the present study, immunological cross-reactivity between 14 chironomid species from different continents was proven by RAST inhibition, double immunodiffusion and a new allergoprint technique, based upon PAGE separation of insect crude extracts. Using isolated chironomid haemoglobins and sera of sensitized persons, as well as rabbit antibodies against larval crude extract or against the haemoglobin fraction of Chironomus thummi, it could be proven that cross-reactivity derives at least predominantly from haemoglobin components with common antigenic determinants in the different species. Images Fig. 2 Fig. 7 Fig. 8 Fig. 9 PMID:6197219

  16. Local descriptive body weight and dietary norms, food availability, and 10-year change in glycosylated haemoglobin in an Australian population-based biomedical cohort

    Directory of Open Access Journals (Sweden)

    Suzanne J. Carroll

    2017-02-01

    Full Text Available Abstract Background Individual-level health outcomes are shaped by environmental risk conditions. Norms figure prominently in socio-behavioural theories yet spatial variations in health-related norms have rarely been investigated as environmental risk conditions. This study assessed: 1 the contributions of local descriptive norms for overweight/obesity and dietary behaviour to 10-year change in glycosylated haemoglobin (HbA1c, accounting for food resource availability; and 2 whether associations between local descriptive norms and HbA1c were moderated by food resource availability. Methods HbA1c, representing cardiometabolic risk, was measured three times over 10 years for a population-based biomedical cohort of adults in Adelaide, South Australia. Residential environmental exposures were defined using 1600 m participant-centred road-network buffers. Local descriptive norms for overweight/obesity and insufficient fruit intake (proportion of residents with BMI ≥ 25 kg/m2 [n = 1890] or fruit intake of <2 serves/day [n = 1945], respectively were aggregated from responses to a separate geocoded population survey. Fast-food and healthful food resource availability (counts were extracted from a retail database. Separate sets of multilevel models included different predictors, one local descriptive norm and either fast-food or healthful food resource availability, with area-level education and individual-level covariates (age, sex, employment status, education, marital status, and smoking status. Interactions between local descriptive norms and food resource availability were tested. Results HbA1c concentration rose over time. Local descriptive norms for overweight/obesity and insufficient fruit intake predicted greater rates of increase in HbA1c. Neither fast-food nor healthful food resource availability were associated with change in HbA1c. Greater healthful food resource availability reduced the rate of increase in HbA1c

  17. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  18. Cross-sectional relationship between haemoglobin concentration and measures of physical and cognitive function in an older rural South African population.

    Science.gov (United States)

    Payne, Collin F; Davies, Justine I; Gomez-Olive, F Xavier; Hands, Katherine J; Kahn, Kathleen; Kobayashi, Lindsay C; Tipping, Brent; Tollman, Stephen M; Wade, Alisha; Witham, Miles D

    2018-04-21

    Age cohort differences in haemoglobin concentrations and associations with physical and cognitive performance among populations of lower income and middle-income countries have not previously been described. We examined the association between these factors among older men and women in rural South Africa. We analysed cross-sectional data from a population-based study of rural South African men and women aged 40 and over (n=4499), with data drawn from questionnaire responses, a cognitive battery, objective physical function tests and blood tests. Anaemia was defined as a haemoglobin concentration age, grip strength, walk speed and a latent cognitive function z-score for men and women separately. We used unadjusted correlations and linear models to adjust for comorbidities and inflammation. In total, 1042 (43.0%) women and 833 (40.1%) men were anaemic. Haemoglobin concentrations were inversely correlated with age for men but not for women; in adjusted analyses, haemoglobin was 0.3 g/dL lower per decade older for men (95% CI 0.2 to 0.4 g/dL). In adjusted analyses, haemoglobin concentration was independently associated with grip strength in women (B=0.391, 95% CI 0.177 to 0.605), but this did not reach significance in men (B=0.266, 95% CI -0.019 to 0.552); no associations were observed between haemoglobin levels and walk speed or cognitive score. Anaemia was prevalent in this study population of middle-aged and older, rural South African adults, but in contrast to high-income countries, it was not associated with poor physical or cognitive function. Our findings need to be replicated in other populations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Nearest neighbors by neighborhood counting.

    Science.gov (United States)

    Wang, Hui

    2006-06-01

    Finding nearest neighbors is a general idea that underlies many artificial intelligence tasks, including machine learning, data mining, natural language understanding, and information retrieval. This idea is explicitly used in the k-nearest neighbors algorithm (kNN), a popular classification method. In this paper, this idea is adopted in the development of a general methodology, neighborhood counting, for devising similarity functions. We turn our focus from neighbors to neighborhoods, a region in the data space covering the data point in question. To measure the similarity between two data points, we consider all neighborhoods that cover both data points. We propose to use the number of such neighborhoods as a measure of similarity. Neighborhood can be defined for different types of data in different ways. Here, we consider one definition of neighborhood for multivariate data and derive a formula for such similarity, called neighborhood counting measure or NCM. NCM was tested experimentally in the framework of kNN. Experiments show that NCM is generally comparable to VDM and its variants, the state-of-the-art distance functions for multivariate data, and, at the same time, is consistently better for relatively large k values. Additionally, NCM consistently outperforms HEOM (a mixture of Euclidean and Hamming distances), the "standard" and most widely used distance function for multivariate data. NCM has a computational complexity in the same order as the standard Euclidean distance function and NCM is task independent and works for numerical and categorical data in a conceptually uniform way. The neighborhood counting methodology is proven sound for multivariate data experimentally. We hope it will work for other types of data.

  20. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  1. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  2. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  3. Prevalence of positive urinary dipstick analysis (leucocyte esterase, nitrite, haemoglobin, or glucose) in a population of 3645 adult subjects--consequence for measurement of urinary albumin excretion rate

    DEFF Research Database (Denmark)

    Clausen, P; Jensen, J S; Borch-Johnsen, K

    1998-01-01

    OBJECTIVES: To assess prevalence of positive urinary dipstick analysis for leucocyte esterase, nitrite, haemoglobin, or glucose in the general population and measure the urinary albumin excretion rate (UAER) in subjects with or without a positive dipstick analysis. DESIGN: A cross-sectional study...... of 3645 subjects. SETTING: An unselected urban population study. MAIN OUTCOME MEASURES: Prevalence data of positive dipstick analyses and UAER values. RESULTS: Prevalence data of a positive dipstick analysis were 12%, 4%, 3% and 6%, respectively, for leucocyte esterase, nitrite, haemoglobin, and glucose...

  4. Deworming drugs for soil-transmitted intestinal worms in children: effects on nutritional indicators, haemoglobin, and school performance

    Science.gov (United States)

    Taylor-Robinson, David C; Maayan, Nicola; Soares-Weiser, Karla; Donegan, Sarah; Garner, Paul

    2015-01-01

    Background The World Health Organization (WHO) recommends treating all school children at regular intervals with deworming drugs in areas where helminth infection is common. As the intervention is often claimed to have important health, nutrition, and societal effects beyond the removal of worms, we critically evaluated the evidence on benefits. Objectives To summarize the effects of giving deworming drugs to children to treat soil-transmitted helminths on weight, haemoglobin, and cognition; and the evidence of impact on physical well-being, school attendance, school performance, and mortality. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register (14 April 2015); Cochrane Central Register of Controlled Trials (CENTRAL), published in the Cochrane Library (2015, Issue 4); MEDLINE (2000 to 14 April 2015); EMBASE (2000 to 14 April 2015); LILACS (2000 to 14 April 2015); the metaRegister of Controlled Trials (mRCT); and reference lists, and registers of ongoing and completed trials up to 14 April 2015. Selection criteria We included randomized controlled trials (RCTs) and quasi-RCTs comparing deworming drugs for soil-transmitted helminths with placebo or no treatment in children aged 16 years or less, reporting on weight, haemoglobin, and formal tests of intellectual development. We also sought data on school attendance, school performance, and mortality. We included trials that combined health education with deworming programmes. Data collection and analysis At least two review authors independently assessed the trials, evaluated risk of bias, and extracted data. We analysed continuous data using the mean difference (MD) with 95% confidence intervals (CIs). Where data were missing, we contacted trial authors. We used outcomes at time of longest follow-up. The evidence quality was assessed using GRADE. This edition of the Cochrane Review adds the DEVTA trial from India, and draws on an independent analytical replication of a trial from

  5. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  6. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  7. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  8. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  9. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  10. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all

  11. Validation of the Hemo_Control instrument for determination of B-haemoglobin concentration in primary health care

    DEFF Research Database (Denmark)

    Aakre, Kristin; Bliksrud, Yngve; Frøyshov, Bess

    2009-01-01

    of the Hemo_Control instrument were calculated after measuring the concentration of venous samples under standardized conditions; by experienced laboratory technicians in a hospital laboratory, and venous and capillary samples under conditions similar to where the instrument is intended for use; by personnel...... was lower than the quality goal of +/- 5% considered acceptable for patient care. High within series imprecision (5.5%) was observed for measurements of capillary blood samples in one of the primary care centres, whereas adequate analytical performance was obtained at the other centre. The Hemo_Control......OBJECTIVE: The aim of this study was to evaluate the analytical performance of a new portable haemoglobinometer, Hemo_Control (EKF-diagnostic, GmbH, Germany), which measures haemoglobin concentration in venous and capillary samples. METHOD: The within series and between series imprecision...

  12. [Peroxynitrite effect on the haemoglobin oxygen affinity in vitro in presence of different partial pressure of carbon dioxide].

    Science.gov (United States)

    Stepuro, T L; Zinchuk, V V

    2011-08-01

    Peroxynitrite (ONOO-) besides its toxic possesses regulatory action that includes the modulation of oxygen binding properties of blood. The aim of this work was to estimate ONOO- effect on the haemoglobin oxygen affinity (HOA) in vitro in presence of different partial pressure of carbon dioxide (CO2). The ONOO- presence in venous blood in conditions of hypercapnia induced oxyhaemoglobin dissociation curve shift leftward while in hypocapnic conditions the result of a different character was obtained. The revealed effect of ONOO- is realized, possibly, through various modifications ofhaemoglobin whose formation is dependent on the CO2 pressure. The ONOO- influences the HOA in different manner that can be important in regulation of blood oxygenation in lungs and maintenance of oxygen consumption in tissues.

  13. Preferred temperature of juvenile Atlantic cod Gadus morhua with different haemoglobin genotypes at normoxia and moderate hypoxia

    DEFF Research Database (Denmark)

    Petersen, M.F.; Steffensen, J.F.

    2003-01-01

    .2+/-1.5 degrees C while HbI-1 cod preferred 15.4+/-1.1 degrees C, and this preference was significant. The effect of hypoxia (35% oxygen saturation) on the preferred temperature was also measured. Previous studies showed that the preferred temperature of fish decreases during hypoxia, and this was the case for Hb......I-1 cod, which preferred 9.8+/-1.8 degrees C during hypoxia, whereas HbI-2 cod did not show this effect. The results indicate that environmental temperature changes will lead to a distributional change in the different haemoglobin types of Atlantic cod, global warming providing an advantage for HbI-1...... cod. However, since HbI-1 cod prefer a low temperature under hypoxic conditions, a combination of increased water temperature and hypoxia could be unfavourable for Atlantic cod stocks....

  14. Effect of moderate hypoxia at three acclimation temperatures on stress responses in Atlantic cod with different haemoglobin types

    DEFF Research Database (Denmark)

    Methling, Caroline; Aluru, Neelakanteswar; Vijayan, Mathilakath M

    2010-01-01

    in a difference in stress response to hypoxia exposure. Two hsp70-isoforms (labelled a and b) were detected and they differed in expression in the gills but not in the liver of Atlantic cod. Acclimation temperature significantly affected the expression of hsp70 in the liver, and in an isoform-specific manner...... in the gills. Hypoxia exposure increased the expression of hsp70 in the liver, but not the gills, of cod and this response was not influenced by the acclimation temperature. The expression of hsp70 in both tissues did not differ between fish with different haemoglobin types. Acclimation temperature...... hypoxic exposure influence the organismal and cellular stress responses in Atlantic cod. We hypothesise that HbI-2 fish are more tolerant to short-term hypoxic episodes than HbI-1 fish, and this adaptation may be independent of tissue hsp70 expression....

  15. Position statement of the Australian Diabetes Society: individualisation of glycated haemoglobin targets for adults with diabetes mellitus.

    Science.gov (United States)

    Cheung, N Wah; Conn, Jennifer J; d'Emden, Michael C; Gunton, Jenny E; Jenkins, Alicia J; Ross, Glynis P; Sinha, Ashim K; Andrikopoulos, Sofianos; Colagiuri, Stephen; Twigg, Stephen M

    2009-09-21

    Tight glycaemic control reduces the risk of development and progression of organ complications in people with type 1 or type 2 diabetes. In this position statement, the Australian Diabetes Society recommends a general target glycated haemoglobin (HbA(1c)) level of position statement also provides guidelines for the individualisation of glycaemic targets to a tighter or lesser degree, with a recommended target HbA(1c) level of diabetes and its duration, pregnancy, diabetes medication being taken, presence of cardiovascular disease, risk of and problems from hypoglycaemia, and comorbidities. Management of diabetes also includes: adequate control of other cardiovascular risk factors, including weight, blood pressure and lipid serum levels; antiplatelet therapy; and smoking cessation.

  16. Hemoglobin, red blood cell count, hematocrit and derived parameters for diagnosing anemia in elderly males

    International Nuclear Information System (INIS)

    Khan, Z.; Nawaz, M.

    2013-01-01

    Anemia is one of the most common micronutrient deficiency in our community. Nutritional anaemias are caused when there is an inadequate body store of a specific nutrient needed for hemoglobin synthesis. The most common nutrient deficiency is of iron. Therefore, a cross-sectional survey was conducted on the healthy elderly male, aged >= 40 and 77 years (n=60) volunteers in order to assess their blood parameters, such as hemoglobin concentration (Hb), hematocrit (HCT), red blood cell count (RBC), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) for the diagnosis of anemia. The demographic results showed mean values (50.10+-8.79) years for age, 66-68 +- 1.95 inches for height , 71.43 +- 6.43 kg body weight, 98.34+-0.48 degree F body temperature, 124 +- 8.67 systolic blood pressure, 82.17 +- 4.15 diastolic pressure while, The pulse rate was found to be 74.63 +- 7.02/minute. Similarly, mean values for lean body weight (LBW) found to be 49.9+-2.89, ideal body weight (IBW) 60.9 +- 4.49, body surface area (BSA) was 1.8 +- 0.1 m2 whereas, body mass index (BMI) showed mean value 24.9 +- 2.6 kg/m2. More so, overall mean Hb found to be 13.60 g/dl, RBC 4.6 mill/mm3, HCT/PCV 43%, MCV 92.95fl, MCH 29.42 pg and MCHC was found to be 31.73 g/dl. The normal range of Hb for men was 13-17 g/dl and 31.67% of the subjects participated in the study was considered to be anemic showing less Hb than normal range. The volunteers were suggested to improve the dietary habits and to take iron supplements in order to overcome the iron deficiency anemia. (author)

  17. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  18. Activating mitochondrial function and haemoglobin expression with EH-201, an inducer of erythropoietin in neuronal cells, reverses memory impairment.

    Science.gov (United States)

    Horng, Lin-Yea; Hsu, Pei-Lun; Chen, Li-Wen; Tseng, Wang-Zou; Hsu, Kai-Tin; Wu, Chia-Ling; Wu, Rong-Tsun

    2015-10-01

    Memory impairment can be progressive in neurodegenerative diseases, and physiological ageing or brain injury, mitochondrial dysfunction and oxidative stress are critical components of these issues. An early clinical study has demonstrated cognitive improvement during erythropoietin treatment in patients with chronic renal failure. As erythropoietin cannot freely cross the blood-brain barrier, we tested EH-201 (2,3,5,4'-tetrahydroxystilbene-2-O-β-d-glucoside, also known as TSG), a low MW inducer of erythropoietin, for its therapeutic effects on memory impairment in models of neurodegenerative diseases, physiological ageing or brain injury. The effects of EH-201 were investigated in astrocytes and PC12 neuronal-like cells. In vivo, we used sleep-deprived (SD) mice as a stress model, amyloid-β (Aβ)-injected mice as a physiological ageing model and kainic acid (KA)-injected mice as a brain damage model to assess the therapeutic effects of EH-201. EH-201 induced expression of erythropoietin, PPAR-γ coactivator 1α (PGC-1α) and haemoglobin in astrocytes and PC12 neuronal-like cells. In vivo, EH-201 treatment restored memory impairment, as assessed by the passive avoidance test, in SD, Aβ and KA mouse models. In the hippocampus of mice given EH-201 in their diet, levels of erythropoietin, PGC-1α and haemoglobin were increased The induction of endogenous erythropoietin in neuronal cells by inducers such as EH-201 might be a therapeutic strategy for memory impairment in neurodegenerative disease, physiological ageing or traumatic brain injury. © 2015 The Authors. British Journal of Pharmacology published by John Wiley & Sons Ltd on behalf of The British Pharmacological Society.

  19. Trimester-specific reference intervals for haemoglobin A(1c) (HbA(1c)) in pregnancy.

    LENUS (Irish Health Repository)

    O'Connor, Catherine

    2011-11-26

    Abstract Background: Diabetes in pregnancy imposes additional risks to both mother and infant. These increased risks are considered to be primarily related to glycaemic control which is monitored by means of glycated haemoglobin (HbA(1c)). The correlation of HbA(1c) with clinical outcomes emphasises the need to measure HbA(1c) accurately, precisely and for correct interpretation, comparison to appropriately defined reference intervals. Since July 2010, the HbA(1c) assay in Irish laboratories is fully metrologically traceable to the IFCC standard. The objective was to establish trimester-specific reference intervals in pregnancy for IFCC standardised HbA(1c) in non-diabetic Caucasian women. Methods: The authors recruited 311 non-diabetic Caucasian pregnant (n=246) and non-pregnant women (n=65). A selective screening based on risk factors for gestational diabetes was employed. All subjects had a random plasma glucose <7.7 mmol\\/L and normal haemoglobin level. Pregnancy trimester was defined as trimester 1 (T1, n=40) up to 12 weeks +6 days, trimester 2 (T2, n=106) 13-27 weeks +6 days, trimester 3 (T3, n=100) >28 weeks to term. Results: The normal HbA(1c) reference interval for Caucasian non-pregnant women was 29-37 mmol\\/mol (Diabetes Control and Complications Trial; DCCT: 4.8%-5.5%), T1: 24-36 mmol\\/mol (DCCT: 4.3%-5.4%), T2: 25-35 mmol\\/mol (DCCT: 4.4%-5.4%) and T3: 28-39 mmol\\/mol (DCCT: 4.7%-5.7%). HbA(1c) was significantly decreased in trimesters 1 and 2 compared to non-pregnant women. Conclusions: HbA(1c) trimester-specific reference intervals are required to better inform the management of pregnancies complicated by diabetes.

  20. Discrete calculus methods for counting

    CERN Document Server

    Mariconda, Carlo

    2016-01-01

    This book provides an introduction to combinatorics, finite calculus, formal series, recurrences, and approximations of sums. Readers will find not only coverage of the basic elements of the subjects but also deep insights into a range of less common topics rarely considered within a single book, such as counting with occupancy constraints, a clear distinction between algebraic and analytical properties of formal power series, an introduction to discrete dynamical systems with a thorough description of Sarkovskii’s theorem, symbolic calculus, and a complete description of the Euler-Maclaurin formulas and their applications. Although several books touch on one or more of these aspects, precious few cover all of them. The authors, both pure mathematicians, have attempted to develop methods that will allow the student to formulate a given problem in a precise mathematical framework. The aim is to equip readers with a sound strategy for classifying and solving problems by pursuing a mathematically rigorous yet ...

  1. Counting paths with Schur transitions

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Pablo [Department of Physics and Astronomy, University of Lethbridge, Lethbridge, Alberta, T1K 3M4 (Canada); Kemp, Garreth [Department of Physics, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Véliz-Osorio, Alvaro, E-mail: aveliz@gmail.com [Mandelstam Institute for Theoretical Physics, University of the Witwatersrand, WITS 2050, Johannesburg (South Africa); School of Physics and Astronomy, Queen Mary, University of London, Mile End Road, London E1 4NS (United Kingdom)

    2016-10-15

    In this work we explore the structure of the branching graph of the unitary group using Schur transitions. We find that these transitions suggest a new combinatorial expression for counting paths in the branching graph. This formula, which is valid for any rank of the unitary group, reproduces known asymptotic results. We proceed to establish the general validity of this expression by a formal proof. The form of this equation strongly hints towards a quantum generalization. Thus, we introduce a notion of quantum relative dimension and subject it to the appropriate consistency tests. This new quantity finds its natural environment in the context of RCFTs and fractional statistics; where the already established notion of quantum dimension has proven to be of great physical importance.

  2. Mass counting of radioactivity samples

    International Nuclear Information System (INIS)

    Oesterlin, D.L.; Obrycki, R.F.

    1977-01-01

    A method and apparatus for concurrently counting a plurality of radioactive samples is claimed. The position sensitive circuitry of a scintillation camera is employed to sort electrical pulses resulting from scintillations according to the geometrical locations of scintillations causing those pulses. A scintillation means, in the form of a scintillating crystal material or a liquid scintillator, is positioned proximate to an array of radioactive samples. Improvement in the accuracy of pulse classification may be obtained by employing collimating means. If a plurality of scintillation crystals are employed to measure the iodine-125 content of samples, a method and means are provided for correcting for variations in crystal light transmission properties, sample volume, and sample container radiation absorption. 2 claims, 7 drawing figures

  3. The inherited diseases of haemoglobin are an emerging global health burden

    Directory of Open Access Journals (Sweden)

    S. Fucharoen

    2011-12-01

    Full Text Available Thalasseamia is one of the common genetic disorders. A genetic defect causes reduction of the globin chains leading to chronic haemolytic anaemia from birth. The mainstay of treatment is blood transfusion to maintain adequate levels of the haemoglobin. Secondary iron overload in β-thalassaemia patients is secondary to multiple blood transfusions and increased iron absorption. Excesses iron potentially catalyses free-radicals generation and impairment in cellular function and integrity. Extensive iron-induced injury develops in the heart, liver, pancreas and endocrine system. In regularly transfused patients, in the absence of iron-chelation therapy, death from iron-induced heart failure occurs by the mid-teenage years. Conventional treatment with the parenteral iron chelator desferrioxamine improves mortality but it is too expensive for middle and lowincome countries. Oral iron chelators, such as deferiprone (L1 and deferasirox, appear to be promising, however, they are still too expensive or need special monitoring. Serum ferritin has been used for many years as a guide for chelation therapy. However, recent studies demonstrated that using serum ferritin or liver iron measurements as a monitor of iron-chelation intensive therapy would have been discontinued long before the iron had cleared from the heart. There is evidence of the value of myocardial T2* measurements by MRI for the detection of early cardiac iron overload which cannot be predicted by liver iron or serum ferritin and for the monitoring of iron-chelation therapy. The major problem is the expensiveness of MRI measurement. In conclusion, the problem of iron chelation in low-income countries may be summarized as follows: i drugs, are not available in every countries that need the medicine, ii the cost of drugs is too high for most low income countries, iii there is poor education of doctor, parents/ patients and local government about the benefit of iron chelation, iv there is need

  4. Bamboo tea: reduction of taxonomic complexity and application of DNA diagnostics based on rbcL and matK sequence data

    Science.gov (United States)

    Häser, Annette

    2016-01-01

    Background Names used in ingredient lists of food products are trivial and in their nature rarely precise. The most recent scientific interpretation of the term bamboo (Bambusoideae, Poaceae) comprises over 1,600 distinct species. In the European Union only few of these exotic species are well known sources for food ingredients (i.e., bamboo sprouts) and are thus not considered novel foods, which would require safety assessments before marketing of corresponding products. In contrast, the use of bamboo leaves and their taxonomic origin is mostly unclear. However, products containing bamboo leaves are currently marketed. Methods We analysed bamboo species and tea products containing bamboo leaves using anatomical leaf characters and DNA sequence data. To reduce taxonomic complexity associated with the term bamboo, we used a phylogenetic framework to trace the origin of DNA from commercially available bamboo leaves within the bambusoid subfamily. For authentication purposes, we introduced a simple PCR based test distinguishing genuine bamboo from other leaf components and assessed the diagnostic potential of rbcL and matK to resolve taxonomic entities within the bamboo subfamily and tribes. Results Based on anatomical and DNA data we were able to trace the taxonomic origin of bamboo leaves used in products to the genera Phyllostachys and Pseudosasa from the temperate “woody” bamboo tribe (Arundinarieae). Currently available rbcL and matK sequence data allow the character based diagnosis of 80% of represented bamboo genera. We detected adulteration by carnation in four of eight tea products and, after adapting our objectives, could trace the taxonomic origin of the adulterant to Dianthus chinensis (Caryophyllaceae), a well known traditional Chinese medicine with counter indications for pregnant women. PMID:27957401

  5. Self-care activities and glycated haemoglobin in Iranian patients with type 2 diabetes: can coping styles and social support have a buffering role?

    Science.gov (United States)

    Shayeghian, Zeinab; Aguilar-Vafaie, Maria E; Besharat, Mohammad Ali; Amiri, Parisa; Parvin, Mahmoud; Gillani, Kobra Roohi; Hassanabadi, Hamidreza

    2015-01-01

    Diabetes self-care is a key element in the overall management of diabetes. However, the importance of psychosocial factors for successful disease management is under investigated. This study aimed at exploring the role of coping styles and social support in the relationship between self-care activities and glycated haemoglobin in patients with type 2 diabetes. One hundred adults (60% female, aged 40-70 years) with type 2 diabetes completed questionnaires assessing self-care activities, coping styles and social support. In addition, a blood test was performed to obtain glycated haemoglobin levels. Result showed significant relationships of glycated haemoglobin with self-care activities, coping styles and social support. Regression analysis indicated that social support had a moderating role on the relationship between self-care activities and glycated haemoglobin, such that, at very high levels of social support the association, between Self-Care and HbA1c disappears. Findings indicate that health care providers, within the context of the Iranian social and cultural situation, should pay more attention to psychosocial factors when addressing self-care activities. Delineation of the role of coping styles and social support might be useful for identifying patients in need of particular counselling and support for improving self-care activities and HbA1c levels.

  6. Purification, crystallization and preliminary crystallographic studies of haemoglobin from mongoose (Helogale parvula) in two different crystal forms induced by pH variation.

    Science.gov (United States)

    Mohamed Abubakkar, M; Saraboji, K; Ponnuswamy, M N

    2013-02-01

    Haemoglobin (Hb) is a respiratory pigment; it is a tetrameric protein that ferries oxygen from the lungs to tissues and transports carbon dioxide on the return journey. The oxygen affinity of haemoglobin is regulated by the concentration of oxygen surrounding it and several efforts have revealed the shapes of Hb in different states and with different functions. However, study of the molecular basis of Hbs from low-oxygen-affinity species is critically needed in order to increase the understanding of the mechanism behind oxygen adaptation. The present study reports the preliminary crystallographic study of low-oxygen-affinity haemoglobin from mongoose, a burrowing mammal. Haemoglobin from mongoose was purified by anion-exchange chromatography, crystallized using the hanging-drop vapour-diffusion method and diffraction data sets were collected from monoclinic (2.3 Å resolution) and orthorhombic (2.9 Å resolution) crystal forms obtained by pH variation. The monoclinic and orthorhombic asymmetric units contained half and a whole biological molecule, respectively.

  7. The predictive value of current haemoglobin levels for incident tuberculosis and/or mortality during long-term antiretroviral therapy in South Africa: a cohort study

    NARCIS (Netherlands)

    Kerkhoff, Andrew D.; Wood, Robin; Cobelens, Frank G.; Gupta-Wright, Ankur; Bekker, Linda-Gail; Lawn, Stephen D.

    2015-01-01

    Low haemoglobin concentrations may be predictive of incident tuberculosis (TB) and death in HIV-infected patients receiving antiretroviral therapy (ART), but data are limited and inconsistent. We examined these relationships retrospectively in a long-term South African ART cohort with multiple

  8. Different functional modulation by heterotropic ligands (2,3-diphosphoglycerate and chlorides) of the two haemoglobins from fallow-deer (Dama dama).

    Science.gov (United States)

    Angeletti, M; Pucciarelli, S; Priori, A M; Canofeni, S; Barra, D; Fioretti, E; Coletta, M

    2001-02-01

    Two haemoglobin components have been identified and purified from fallow-deer (Dama dama) erythrocytes. They are present in similar amounts and the two tetrameric molecules share the same alpha chain, while two different beta chains are detected in the two components. The beta chains differ by 14 residues, even though they both have 145 amino-acid residues, which account for a molecular mass of 16,023 and 16,064 Da, respectively, while alpha chain has 141 residues, yielding a molecular mass of 15,142 Da. Compared with human Hb, the N-terminal region of both beta chains shows deletion of Val beta 1 and the replacement of His beta 2 by a methionyl residue, a modification which is common to most ruminant haemoglobins. Although both isolated components show a low intrinsic affinity for oxygen, meaningful differences between the two haemoglobins have been found with respect to the effect of heterotropic effectors, such as 2,3-diphosphoglycerate and chloride ions. In view of the high sequence homology between the two components, the different effect of heterotropic ligands has been tentatively correlated to possible localized structural variations between beta chains of the two haemoglobin components.

  9. Randomised feasibility study of a more liberal haemoglobin trigger for red blood cell transfusion compared to standard practice in anaemic cancer patients treated with chemotherapy

    DEFF Research Database (Denmark)

    Yakymenko, D.; Frandsen, K. B.; Christensen, I. J.

    2017-01-01

    Objectives: The primary objective of this feasibility study was to identify quality of life (QoL) scores and symptom scales as tools for measuring patient-reported outcomes (PRO) associated with haemoglobin level in chemotherapy-treated cancer patients. Secondary objectives included comparing QoL......-An, FACT-An TOI, fatigue and dyspnoea. Conclusions: QoL scores of physical and functional domains as well as self-reported anaemia-related symptoms correlated well with haemoglobin level in chemotherapy-treated cancer patients.......Objectives: The primary objective of this feasibility study was to identify quality of life (QoL) scores and symptom scales as tools for measuring patient-reported outcomes (PRO) associated with haemoglobin level in chemotherapy-treated cancer patients. Secondary objectives included comparing Qo......L and symptoms between randomisation arms. Background: Anaemia in cancer patients undergoing chemotherapy is associated with decreased QoL. One treatment option is red blood cell transfusion (RBCT). However, the optimal haemoglobin trigger for transfusion is unknown. Methods: Patients were randomised...

  10. CORD BLOOD NUCLEATED RED BLOOD CELL COUNT: A SIMPLE BEDSIDE TEST OF PERINATAL ASPHYXIA AND ITS CORRELATION WITH IMMEDIATE OUTCOME

    Directory of Open Access Journals (Sweden)

    Ramesh Chand

    2016-07-01

    Full Text Available BACKGROUND Asphyxia is a leading cause of foetal neonatal mortality and morbidity. Nucleated red blood cell count (NRBC produced as compensatory response to asphyxia in foetus and NRBC level can be correlated to asphyxia. Because the present indices are unhelpful in the diagnosis and prediction of the severity of asphyxia, we wished to investigate the relationship between the nucleated RBC count and the severity & immediate outcome of perinatal asphyxia. METHOD This prospective comparative study was conducted in maternity ward of Obstetrics & Gynaecology Department and Paediatric Department of GSVM Medical College, Kanpur (Central UP, from January 2014 to September 2014. Newborns of term gestation were selected after satisfying inclusion criteria and were divided in 2 groups. The control group consisted 60 normal newborns and case group had 60 asphyxiated newborns. The cord blood was collected soon after birth, investigated for pH and making smears that were stained with Leishman’s stain. NRBCs were counted against 100 WBCs. The statistical analysis was done using IMSTAT. RESULTS The mean NRBC count in the study group was 22.63±6.95 as compared to 4.75±2.04 in the control group (p=<0.0001. The NRBC count was significantly higher in low pH, neonates with low Apgar scores of < 3 at 1 minutes, newborns with HIE stage III & in neonates who were neurological abnormal at discharge (P=0.0001. CONCLUSIONS A simple, easy to do, cost effective bedside test, such as NRBC count at time of delivery is a good marker of perinatal asphyxia & its forthcoming immediate neurological outcome.

  11. The effect on haemoglobin of the use of iron cooking pots in rural Malawian households in an area with high malaria prevalence: a randomized trial.

    Science.gov (United States)

    Geerligs, Paul Prinsen; Brabin, Bernard; Mkumbwa, Albert; Broadhead, Robin; Cuevas, Luis E

    2003-04-01

    Innovative low-cost sustainable strategies are required to reduce the high prevalence of iron-deficiency anaemia in developing countries. We undertook a community-based randomized controlled intervention trial to assess the effects of cooking in iron or aluminium cooking pots in Malawian households in an area with high malaria prevalence. Analysis was by intention to treat and consistency of use. The primary outcomes were change in haemoglobin and iron status. The study population comprised 164 participants eating from aluminium cooking pots and 158 from iron cooking pots. The mean haemoglobin change was significantly increased after 6 weeks in adults who consistently ate from an iron cooking pot (+3.6 g/l compared to -3.2 g/l, mean difference between groups 6.8 g/l, 95% CI +0.86, +12.74). In children, no significant haemoglobin change was observed in consistent pot users, although they showed a significant reduction in iron deficiency (iron 8.6 ZP/g and aluminium 10.8 ZP/g, mean difference 2.2 ZP/g, 95% CI +1.08, +3.32). Rural Malawian adults in a high malaria transmission area who consistently consume food prepared in iron cooking pots show a significant rise in haemoglobin after 6 weeks use. Children showed a reduction in iron deficiency, but no significant improvement in haemoglobin, possibly because of their high malaria parasite prevalence. Using iron cooking pots in developing countries could provide an innovative way to prevent iron deficiency and anaemia in malarious areas where regular iron supplementation is problematic.

  12. Counting Zero: Rethinking Feminist Epistemologies

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2017-10-01

    Full Text Available This article concerns feminist engagements with epistemologies. Feminist epistemologies have revealed and challenged the exclusions and denigrations at work in knowledge production processes. And yet, the emphasis on the partiality of knowledge and the non-innocence of any subject position also cast doubt on the possibility of feminist political communities. In view of this, it has been argued that the very parameter of epistemology poses limitations for feminism, for it leads to either political paralysis or prescriptive politics that in fact undoes the political of politics. From a different perspective, decolonial feminists argue for radical epistemic disobedience and delinking the move beyond the confines of Western systems of knowledge and its extractive knowledge economy. Nevertheless, the oppositional logic informs both feminist epistemologies and its critiques, which I argue is symptomatic of the epistemic habits of academic feminism. This article ends with a preliminary reconsideration of the question of origin through the figure of zero. It asks whether it might be possible to conceive of feminist epistemologies as performing the task of counting zero – accounting for origin, wholeness, and universality – that takes into account specificities without forfeiting coalition and claims to knowledge.

  13. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  14. Leveraging multiple datasets for deep leaf counting

    OpenAIRE

    Dobrescu, Andrei; Giuffrida, Mario Valerio; Tsaftaris, Sotirios A

    2017-01-01

    The number of leaves a plant has is one of the key traits (phenotypes) describing its development and growth. Here, we propose an automated, deep learning based approach for counting leaves in model rosette plants. While state-of-the-art results on leaf counting with deep learning methods have recently been reported, they obtain the count as a result of leaf segmentation and thus require per-leaf (instance) segmentation to train the models (a rather strong annotation). Instead, our method tre...

  15. Resonance ionization spectroscopy: Counting noble gas atoms

    International Nuclear Information System (INIS)

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-01-01

    The purpose of this paper is to describe new work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions). When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. We show that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective. (orig./FKS)

  16. The hematology of captive Bobtail lizards (Tiliqua rugosa): blood counts, light microscopy, cytochemistry, and ultrastructure.

    Science.gov (United States)

    Moller, Cheryl A; Gaál, Tibor; Mills, Jennifer N

    2016-12-01

    Bobtail lizards (Tiliqua rugosa) are native to Australia. The only previous study on the hematology of this species documented just 6 animals. The aims of this study were to characterize the light microscopy, ultrastructure and cytochemistry of blood cells, and evaluate CBCs of captive Bobtail lizards. Over 2 consecutive summers, heparinized venous blood was collected from the ventral coccygeal vein of 46 clinically healthy, captive indoor- or outdoor-housed adult Bobtails. Complete blood cell counts and smear evaluations were performed, and cytochemical stains and transmission electron microscopy were used to further characterize blood cells. The eosinophils of this species were uniformly vacuolated: a unique feature not previously reported in reptiles. Heterophils were the predominant leukocyte, with fewer lymphocytes, azurophilic and nonazurophilic monocytes, occasional eosinophils, and basophils. Thrombocytes were frequently clumped. Slight polychromasia (0-15% of erythrocytes) was typically present. Hemogregarine parasites were seen on some smears. The range of CBC results was often wide. The PCV ranged from 11% to 38%. Total plasma proteins by refractometry were between 3.5 and 7.8 g/dL. Hemoglobin ranged between 2.6 and 12.6 g/dL by the modified hemoglobin-hydroxylamine method. Manual RBC count was 0.35-1.27 × 10 6 /μL, and WBC count was 2.86-22.66 × 10 3 /μL. Bobtail lizards housed outdoors had lower PCVs than indoor-housed animals. Bobtails with hemogregarine infections had lower PCVs than noninfected lizards. Ranges for CBC data were often very wide, influenced by preanalytic and analytic factors. Hemogregarine infection is associated with a decreased PCV, suggesting that some hemogregarine species are pathogenic in this population. © 2016 American Society for Veterinary Clinical Pathology.

  17. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  18. Haematological parameters and recurrent aphthous stomatitis

    International Nuclear Information System (INIS)

    Khan, N. F.; Saeed, M.; Chaudhary, S.

    2013-01-01

    Objective: To find out the relationship between recurrent aphthous stomatitis (RAS) with deficiencies of haemoglobin, haematocrit, serum vitamin B12, serum Ferritin and red blood cells (RBC) Folate level. Study Design: An analytical cross-sectional study. Place and Duration of Study: Department of Oral Health Sciences, Shaikh Zayed Federal Postgraduate Medical Complex, Lahore, from February to July 2008. Methodology: Sixty consecutive subjects with active RAS were taken as the aphthous group; 60 age and gender matched subjects without RAS were as the Non-Aphthous group. Five milliliter blood was taken from both groups to evaluate the levels of serum B12, and RBC Folate through radio immuno assay and serum ferritin with enzyme linked immuno-sorbent assay tests. Complete blood count was carried out to determine the level of haemoglobin and haematocrit in both groups. Proportion of subjects with lower values was compared using 2 text of proportions with significance at p < 0.05. Results: Serum Ferritin (p = 0.001), haematocrit (p < 0.001), RBC Folate (p < 0.001) and serum B12 (p < 0.001) were significantly lower in the RAS group. Combined deficiency state (haemoglobin, serum Ferritin, haematocrit, RBC Folate and serum B12) was identified in 13% (n = 8) RAS patients. Conclusion: Frequency of haematinic deficiencies was high in RAS patients. Serum B12 and RBC Folate were significantly low in aphthous group. (author)

  19. Use of Laser Assisted Optical Rotational Cell Analyzer (LoRRca MaxSis in the Diagnosis of RBC Membrane Disorders, Enzyme Defects, and Congenital Dyserythropoietic Anemias: A Monocentric Study on 202 Patients

    Directory of Open Access Journals (Sweden)

    Anna Zaninoni

    2018-04-01

    Full Text Available Chronic hemolytic anemias are a group of heterogeneous diseases mainly due to abnormalities of red cell (RBC membrane and metabolism. The more common RBC membrane disorders, classified on the basis of blood smear morphology, are hereditary spherocytosis (HS, elliptocytosis, and hereditary stomatocytoses (HSt. Among RBC enzymopathies, the most frequent is pyruvate kinase (PK deficiency, followed by glucose-6-phosphate isomerase, pyrimidine 5′ nucleotidase P5′N, and other rare enzymes defects. Because of the rarity and heterogeneity of these diseases, diagnosis may be often challenging despite the availability of a variety of laboratory tests. The ektacytometer laser-assisted optical rotational cell analyser (LoRRca MaxSis, able to assess the RBC deformability in osmotic gradient conditions (Osmoscan analysis, is a useful diagnostic tool for RBC membrane disorders and in particular for the identification of hereditary stomatocytosis. Few data are so far available in other hemolytic anemias. We evaluated the diagnostic power of LoRRca MaxSis in a large series of 140 patients affected by RBC membrane disorders, 37 by enzymopathies, and 16 by congenital diserythropoietic anemia type II. Moreover, nine patients with paroxysmal nocturnal hemoglobinuria (PNH were also investigated. All the hereditary spherocytoses, regardless the biochemical defect, showed altered Osmoscan curves, with a decreased Elongation Index (EI max and right shifted Omin; hereditary elliptocytosis (HE displayed a trapezoidal curve and decreased EImax. Dehydrated hereditary stomatocytosis (DHSt caused by PIEZO1 mutations was characterized by left-shifted curve, whereas KCNN4 mutations were associated with a normal curve. Congenital diserythropoietic anemia type II and RBC enzymopathies had Osmoscan curve within the normal range except for glucosephosphate isomerase (GPI deficient cases who displayed an enlarged curve associated with significantly increased Ohyper, offering a

  20. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  1. Is It Counting, or Is It Adding?

    Science.gov (United States)

    Eisenhardt, Sara; Fisher, Molly H.; Thomas, Jonathan; Schack, Edna O.; Tassell, Janet; Yoder, Margaret

    2014-01-01

    The Common Core State Standards for Mathematics (CCSSI 2010) expect second grade students to "fluently add and subtract within 20 using mental strategies" (2.OA.B.2). Most children begin with number word sequences and counting approximations and then develop greater skill with counting. But do all teachers really understand how this…

  2. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  3. Lazy reference counting for the Microgrid

    NARCIS (Netherlands)

    Poss, R.; Grelck, C.; Herhut, S.; Scholz, S.-B.

    2012-01-01

    This papers revisits non-deferred reference counting, a common technique to ensure that potentially shared large heap objects can be reused safely when they are both input and output to computations. Traditionally, thread-safe reference counting exploit implicit memory-based communication of counter

  4. A Word Count of Modern Arabic Prose.

    Science.gov (United States)

    Landau, Jacob M.

    This book presents a word count of Arabic prose based on 60 twentieth-century Egyptian books. The text is divided into an alphabetical list and a word frequency list. This word count is intended as an aid in the: (1) writing of primers and the compilation of graded readers, (2) examination of the vocabulary selection of primers and readers…

  5. 2013 Kids Count in Colorado! Community Matters

    Science.gov (United States)

    Colorado Children's Campaign, 2013

    2013-01-01

    "Kids Count in Colorado!" is an annual publication of the Children's Campaign, providing state and county level data on child well-being factors including child health, education, and economic status. Since its first release 20 years ago, "Kids Count in Colorado!" has become the most trusted source for data and information on…

  6. Complete blood count reference values of cord blood in Taiwan and the influence of gender and delivery route on them.

    Science.gov (United States)

    Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey

    2011-06-01

    Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (pTaiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.

  7. Evaluación de la estrategia de rehabilitación de base comunitaria (RBC desde la perspectiva de la comunidad y los equipos locales de rehabilitación

    Directory of Open Access Journals (Sweden)

    Alejandro Guajardo Córdoba

    2015-09-01

    Full Text Available A través de este proyecto de investigación se evalúo, desde la perspectiva de la comunidad y los equipos locales de rehabilitación en Chile, los distintos niveles de intervención de la RBC. Así, el objetivo que guío esta investigación fue evaluar el impacto social percibido y la aceptabilidad social de la estrategia de Rehabilitación de Base Comunitaria (RBC desde la perspectiva de la comunidad y los equipos locales de rehabilitación. El marco metodológico fue definido bajo los parámetros de una investigación cualitativa de carácter descriptivo y transversal. El universo de estudio correspondió a las comunas que contaban con programas de RBC que se desarrollan a nivel nacional como parte de la política nacional de discapacidad y rehabilitación en salud. Los criterios que guiaron el proceso de muestreo fueron los de pertinencia y suficiencia de la información, por lo que  se optó  por un muestreo estructural. El procesamiento de los datos se realizó mediante análisis de contenido semánticamente orientado, siguiendo una estratega intensiva, es decir, se analizó toda la información producida durante la fase de terreno. Los resultados dan cuenta de la RBC como una estrategia  con variadas formas de implementación y desarrollo que se relaciona con la historia local, el perfil de la comunidad, perfil del centro,  perfil de usuarias/ios y las características de vinculación municipal con el programa de rehabilitación. El estudio identifica en la estrategia de RBC tres modelos de acción: biomédico, biopsicosocial y comunitario.

  8. A Systematic Review of Known Mechanisms of Hydroxyurea-induced Foetal Haemoglobin for Treatment of Sickle Cell Disease

    Science.gov (United States)

    Pule, Gift D.; Mowla, Shaheen; Novitzky, Nicolas; Wiysonge, Charles S.; Wonkam, Ambroise

    2016-01-01

    Aims To report on molecular mechanisms of foetal haemoglobin (HbF) induction by hydroxyurea (HU) for the treatment of Sickle Cell Disease (SCD). Study Design Systematic review. Results Studies have provided consistent associations between genomic variations in HbF-promoting loci and variable HbF level in response to HU. Numerous signal transduction pathways have been implicated, through the identification of key genomic variants in BCL11A, HBS1L-MYB, SAR1 or XmnI polymorphism that predispose the response to the treatment, and signal transduction pathways, that modulate γ-globin expression (cAMP/cGMP; Giα/JNK/Jun; methylation and microRNA). Three main molecular pathways have been reported: 1) Epigenetic modifications, transcriptional events and signalling pathways involved in HU-mediated response, 2) Signalling pathways involving HU-mediated response and 3) Post-transcriptional pathways (regulation by microRNAs). Conclusions The complete picture of HU-mediated mechanisms of HbF production in SCD remains elusive. Research on post-transcriptional mechanisms could lead to therapeutic targets that may minimize alterations to the cellular transcriptome. PMID:26327494

  9. Distribution of glycated haemoglobin and its determinants in Korean youth and young adults: a nationwide population-based study.

    Science.gov (United States)

    Seo, Ji-Young; Hwang, Seung-Sik; Kim, Jae Hyun; Lee, Young Ah; Lee, Seong Yong; Shin, Choong Ho; Yang, Sei Won

    2018-01-31

    The present study aimed to describe the distribution of and to investigate the factors associated with glycated haemoglobin (HbA1c) values in Korean youth (10-19 years old) and young adults (20-29 years old). Data from the Korea Health and Nutrition Examination Survey (2011-2015) were used. A total of 6,418 participants (male 3,140 [53.2%]) aged 10-29 years were included in the analysis. Percentiles of HbA1c were calculated and HbA1c values were compared according to age, sex, and associated factors. The mean HbA1c values (% [mmol/mol]) were 5.42 ± 0.01 (35.7 ± 0.1) for youths and 5.32 ± 0.01 (34.7 ± 0.1) for young adults (P distribution of HbA1c values in Korean youth and young adults. There were significant differences in the level of HbA1c according to age and sex.

  10. Effect of dietary Fe-deficiency on growth organ weight, haemoglobin formation and 59Fe-retention in rats

    International Nuclear Information System (INIS)

    Sinha, R.K.; Gautam, D.

    1985-01-01

    Rats of the experimental group consuming diets adequate in all respects, but deficient in iron (5 ppm iron in contrast to 50 ppm iron for the control group) were found to suffer from moderate to severe anaemia (Hb 7.39 ± 0.2 g/100 ml, in contrast to 13.88 ± 0.19 g/100 ml for the control group; PCV per cent 27.88 ± 0.76 in contrast to 43.82 ± 0.65 for the control group) whereas they had satisfactory growth rates and normal outward appearance in all respects. However, their spleen and heart weight/g of body weight were also found to be significantly reduced, though liver and kidney weights remained normal. Their 59 Fe retention was considerably more than that of the control group indicating iron absorption and uptake were entirely dependent on iron-storage or haemoglobin status of the body. The results indicated that even for almost normal growth and a deceptive normal outward appearance a subject could be actually morbid because of Fe-deficiency anaemia under conditions of otherwise adequate diets and sedentary activity. (author)

  11. Changes in levels of haemoglobin A1c during the first 6 years after diagnosis of clinical type 2 diabetes

    DEFF Research Database (Denmark)

    Olivarius, Niels de Fine; Siersma, V.; Hansen, Lars Jørgen

    2009-01-01

    in HbA(1c) was investigated in a multivariate mixed model. RESULTS: During the first year after diabetes diagnosis, HbA(1c) dropped to near normal average level and then started rising almost linearly. A sharp rise in long-term glycaemic level was observed in approximately a quarter of the patients......OBJECTIVE: To assess the variability in levels of glycosylated haemoglobin (HbA(1c)) during the first six years after diagnosis of clinical type 2 diabetes in relation to possible predictors. MATERIAL AND METHODS: Data were from a population-based sample from general practice of 581 newly diagnosed...... diabetic patients aged 40 or over. Estimation of HbA(1c) was centralized. The changes in levels of HbA(1c) were described by HbA(1c) at diagnosis and a regression line fitted to the HbA(1c) measurements after 1-year follow-up for each patient. The predictive effect of patient characteristics for changes...

  12. Alpha- and beta-cell abnormalities in haemoglobin A1c-defined prediabetes and type 2 diabetes

    DEFF Research Database (Denmark)

    Calanna, Salvatore; Scicali, Roberto; Di Pino, Antonino

    2014-01-01

    New recommendations for the use of glycated haemoglobin A1c (HbA1c) to diagnose prediabetes and type 2 diabetes have changed the constitution of the two populations. We aimed to investigate the pathophysiological characteristics of individuals with HbA1c-defined prediabetes and type 2 diabetes......, respectively. Ten subjects with HbA1c-defined prediabetes, i.e. HbA1c from 5.7 to 6.4 % (39-46 mmol/mol), eight newly diagnosed patients with HbA1c-defined type 2 diabetes [HbA1c ≥6.5 % (≥48 mmol/mol)], and ten controls with HbA1c lower than 5.7 % (.... Subjects with HbA1c-defined prediabetes showed significantly lower insulinogenic index (P = 0.02), disposition index (P = 0.001), and glucagon suppression compared with controls; and similar (P = NS) insulinogenic index and glucagon suppression and higher disposition index (P = 0.02) compared to HbA1c...

  13. Comparative clinical evaluation of glycosylated haemoglobin level in healthy and chronic periodontitis patients: A chairside diagnostic method.

    Science.gov (United States)

    Srinivasa, T S; Agrawal, Parul; Goyal, Pravesh; Farista, Sana; Sowmya, N K; Deonani, Sushmita

    2015-01-01

    Glycosylated haemoglobin (HbA1c) level can consequently be interpreted as an average of the blood glucose present over the past 3-4 months. Periodontitis is associated with glycemic control in patients with diabetes. The purpose of this study was to determine the level of HbA1c in healthy and periodontitis patients who were previously not diagnosed with diabetes mellitus. A total of 40 patients were selected for study and divided into two groups. Group 1 included patients with a healthy periodontium, and Group 2 included patients suffering from chronic periodontitis. Finger stick blood was collected by special collection unit (A1CNOW+® Bayer Health Care, Tarrytown New York, USA), for estimating level of HbA1c. Both groups showed similar HbA1c levels clinically with slight increase in levels in the test group, but was statistically significant (test--5.66 ± 0.35%, control--5.17 ± 0.3% P = 0.003). Indians are at a high-risk of developing periodontitis and diabetes. These data suggest a possible link between periodontitis and glycemic control in nondiabetic individuals, periodontal disease may be a potential contributor to the development of type 2 diabetes.

  14. Comparative clinical evaluation of glycosylated haemoglobin level in healthy and chronic periodontitis patients: A chairside diagnostic method

    Directory of Open Access Journals (Sweden)

    T S Srinivasa

    2015-01-01

    Full Text Available Objective and Background: Glycosylated haemoglobin (HbA1c level can consequently be interpreted as an average of the blood glucose present over the past 3-4 months. Periodontitis is associated with glycemic control in patients with diabetes. The purpose of this study was to determine the level of HbA1c in healthy and periodontitis patients who were previously not diagnosed with diabetes mellitus. Materials and Methods: A total of 40 patients were selected for study and divided into two groups. Group 1 included patients with a healthy periodontium, and Group 2 included patients suffering from chronic periodontitis. Finger stick blood was collected by special collection unit (A1CNOW +® Bayer Health Care, Tarrytown New York, USA, for estimating level of HbA1c. Result: Both groups showed similar HbA1c levels clinically with slight increase in levels in the test group, but was statistically significant (test - 5.66 ± 0.35%, control - 5.17 ± 0.3% P = 0.003. Conclusion: Indians are at a high-risk of developing periodontitis and diabetes. These data suggest a possible link between periodontitis and glycemic control in nondiabetic individuals, periodontal disease may be a potential contributor to the development of type 2 diabetes.

  15. Grateloupia tenuis Wang et Luan sp. nov. (Halymeniaceae, Rhodophyta: A New Species from South China Sea Based on Morphological Observation and rbcL Gene Sequences Analysis

    Directory of Open Access Journals (Sweden)

    Ling Yu

    2013-01-01

    Full Text Available Grateloupia tenuis Wang et Luan sp. nov. is a new species described from Lingshui, Hainan Province, South China Sea. Based on the external form and internal structure, combined with rbcL gene sequence analysis, Grateloupia tenuis is distinct from other Grateloupia species as follows: (1 thalli is slippery and cartilaginous in texture; possess fewer branches, relatively slight main axes, and two or three dichotomous branches; (2 cortex is 5-6 layers; medulla is solid when young, but hollow in old branches; reproductive structures are dispersed in main axes of thalli and lower portions of branchlets; exhibits Grateloupia-type auxiliary cell ampullae; (3 the four studied G. tenuis sequences were positioned in a large Grateloupia clade of Halymeniaceae, which included sister group generitype G. filicina with 68 bp differences; G. tenuis was determined to be a sister taxon to the G. catenata, G. ramosissima, G. orientalis, and G. filiformis subclade. The pairwise distances between G. tenuis and these species were 39 to 50 bp. The sequences of G. tenuis differed by 81–108 bp from the sequences of other samples in Grateloupia; there are 114–133 bp changes between G. tenuis and other genera of Halymeniaceae. In final analysis, we considered Grateloupia tenuis Wang et Luan sp. nov. to be a new species of genus Grateloupia.

  16. Grateloupia tenuis Wang et Luan sp. nov. (Halymeniaceae, Rhodophyta): a new species from South China Sea based on morphological observation and rbcL gene sequences analysis.

    Science.gov (United States)

    Yu, Ling; Wang, Hongwei; Luan, Rixiao

    2013-01-01

    Grateloupia tenuis Wang et Luan sp. nov. is a new species described from Lingshui, Hainan Province, South China Sea. Based on the external form and internal structure, combined with rbcL gene sequence analysis, Grateloupia tenuis is distinct from other Grateloupia species as follows: (1) thalli is slippery and cartilaginous in texture; possess fewer branches, relatively slight main axes, and two or three dichotomous branches; (2) cortex is 5-6 layers; medulla is solid when young, but hollow in old branches; reproductive structures are dispersed in main axes of thalli and lower portions of branchlets; exhibits Grateloupia-type auxiliary cell ampullae; (3) the four studied G. tenuis sequences were positioned in a large Grateloupia clade of Halymeniaceae, which included sister group generitype G. filicina with 68 bp differences; G. tenuis was determined to be a sister taxon to the G. catenata, G. ramosissima, G. orientalis, and G. filiformis subclade. The pairwise distances between G. tenuis and these species were 39 to 50 bp. The sequences of G. tenuis differed by 81-108 bp from the sequences of other samples in Grateloupia; there are 114-133 bp changes between G. tenuis and other genera of Halymeniaceae. In final analysis, we considered Grateloupia tenuis Wang et Luan sp. nov. to be a new species of genus Grateloupia.

  17. Grateloupia ramosa Wang & Luan sp. nov. (Halymeniaceae, Rhodophyta), a new species from China based on morphological evidence and comparative rbcL sequences

    Science.gov (United States)

    Cao, Cuicui; Liu, Miao; Guo, Shaoru; Zhao, Dan; Luan, Rixiao; Wang, Hongwei

    2016-03-01

    Grateloupia ramosa Wang & Luan sp. nov. (Halymeniaceae, Rhodophyta) is newly described from Hainan Province, southern China. The organism has the following morphological features: (1) purplish red, cartilaginous and lubricous thalli 5-10 cm in height; (2) compressed percurrent axes bearing abundant branches with opposite arrangement; (3) claw-like apices on top, constricted to 2-4 cm at the base; (4) cortex consisting of 3-6 layers of elliptical or anomalous cells and a medulla covered by compact medullary filaments; (5) reproductive structures distributed throughout the thallus, especially centralized at the bottom of the end portion of the branches; and (6) 4-celled Carpogonial branches and 3-celled auxiliary-cell branches, both of the Grateloupia-type. The morphological diff erences were supported by molecular phylogenetics based on ribulose-1, 5-bisphosphate carboxylase/oxygenase ( rbcL) gene sequence analysis. There was only a 1 bp divergence between specimens collected from Wenchang and Lingshui of Hainan province. The new species was embedded in the large Grateloupia clade of the Halymeniaceae. The pairwise distances between G. ramosa and other species within Grateloupia ranged from 26 to 105 bp, within pairwise distances of 13-111 bp between species of the large genus Grateloupia in Halymeniaceae. Thus, we propose this new species as G. ramosa Wang & Luan sp. nov.

  18. Grateloupia tenuis Wang et Luan sp. nov. (Halymeniaceae, Rhodophyta): A New Species from South China Sea Based on Morphological Observation and rbcL Gene Sequences Analysis

    Science.gov (United States)

    Wang, Hongwei; Luan, Rixiao

    2013-01-01

    Grateloupia tenuis Wang et Luan sp. nov. is a new species described from Lingshui, Hainan Province, South China Sea. Based on the external form and internal structure, combined with rbcL gene sequence analysis, Grateloupia tenuis is distinct from other Grateloupia species as follows: (1) thalli is slippery and cartilaginous in texture; possess fewer branches, relatively slight main axes, and two or three dichotomous branches; (2) cortex is 5-6 layers; medulla is solid when young, but hollow in old branches; reproductive structures are dispersed in main axes of thalli and lower portions of branchlets; exhibits Grateloupia-type auxiliary cell ampullae; (3) the four studied G. tenuis sequences were positioned in a large Grateloupia clade of Halymeniaceae, which included sister group generitype G. filicina with 68 bp differences; G. tenuis was determined to be a sister taxon to the G. catenata, G. ramosissima, G. orientalis, and G. filiformis subclade. The pairwise distances between G. tenuis and these species were 39 to 50 bp. The sequences of G. tenuis differed by 81–108 bp from the sequences of other samples in Grateloupia; there are 114–133 bp changes between G. tenuis and other genera of Halymeniaceae. In final analysis, we considered Grateloupia tenuis Wang et Luan sp. nov. to be a new species of genus Grateloupia. PMID:24455703

  19. Phylogeny of the Celastraceae inferred from 26S nuclear ribosomal DNA, phytochrome B, rbcL, atpB, and morphology.

    Science.gov (United States)

    Simmons, M P; Savolainen, V; Clevinger, C C; Archer, R H; Davis, J I

    2001-06-01

    Phylogenetic relationships within Celastraceae (spindle-tree family) were inferred from nucleotide sequence characters from the 5' end of 26S nuclear ribosomal DNA (including expansion segments D1-D3; 84 species sampled), phytochrome B (58 species), rbcL (31 species), atpB (23 species), and morphology (94 species). Among taxa of questionable affinity, Forsellesia is a member of Crossosomataceae, and Goupia is excluded from Celastraceae. However, Brexia, Canotia, Lepuropetalon, Parnassia, Siphonodon, and Stackhousiaceae are supported as members of Celastraceae. Gymnosporia and Tricerma are distinct from Maytenus, Cassine is supported as distinct from Elaeodendron, and Dicarpellum is distinct from Salacia. Catha, Maytenus, and Pristimera are not resolved as natural genera. Hippocrateaceae (including Plagiopteron and Lophopetalum) are a clade nested within a paraphyletic Celastraceae. These data also suggest that the Loesener's classification of Celastraceae sensu stricto and Hallé's classification of Hippocrateaceae are artificial. The diversification of the fruit and aril within Celastraceae appears to be complex, with multiple origins of most fruit and aril forms. Copyright 2001 Academic Press.

  20. Restoration of Haemoglobin Level Using Hydrodynamic Gene Therapy with Erythropoietin Does Not Alleviate the Disease Progression in an Anaemic Mouse Model for TGFβ1-Induced Chronic Kidney Disease

    DEFF Research Database (Denmark)

    Pedersen, Lea Hougaard; Wogensen, Lise; Marcussen, N.

    2015-01-01

    . The experiment is conducted by hydrodynamic gene transfer of a plasmid encoding murine Epo in a transgenic mouse model that overexpresses TGF-β1 locally in the kidneys. This model develops anaemia due to chronic kidney disease characterised by thickening of the glomerular basement membrane, deposition...... of mesangial matrix and mild interstitial fibrosis. A group of age matched wildtype littermates are treated accordingly. After a single hydrodynamic administration of plasmid DNA containing murine EPO gene, sustained high haemoglobin levels are observed in both transgenic and wildtype mice from 7.5 ± 0.6 mmol...... treatment in this model of chronic kidney disease normalises haemoglobin levels but has no effect on kidney fibrosis or function....

  1. A comparison of post-op haemoglobin levels and allogeneic blood transfusion rates following total knee arthroplasty without drainage or with reinfusion drains.

    Science.gov (United States)

    Hazarika, Shariff; Bhattacharya, Rajarshi; Bhavikatti, Mainudden; Dawson, Matthew

    2010-02-01

    The effects of re-infusion drains on the rate of allogeneic blood transfusion and post-op haemoglobin levels in Total Knee Arthroplasty were examined. A group of 22 patients undergoing primary Total Knee Arthroplasty using a CBCII Constavac Stryker re-infusion drainage system were compared with a group of 30 patients, matched for age, sex and type of prosthesis but without any drain usage. The re-infusion drain.group had a significantly lower day 1 and day 3 post-operative haemoglobin compared to the non-drainage group. The re-infusion drain group had a higher allogenic transfusion rate compared to the non-drainage group. There were no significant differences between the two groups regarding the rate of wound and transfusion related complications and mean length of post-operative stay. We found that reinfusion drains were ineffective in reducing allogeneic transfusion requirements as compared with non-drainage in total knee arthroplasty.

  2. Rapid screening for glucose-6-phosphate dehydrogenase deficiency and haemoglobin polymorphisms in Africa by a simple high-throughput SSOP-ELISA method

    DEFF Research Database (Denmark)

    Enevold, Anders; Vestergaard, Lasse S; Lusingu, John

    2005-01-01

    was available. METHODS: A simple and rapid technique was developed to detect the most prominent single nucleotide polymorphisms (SNPs) in the HbB and G6PD genes. The method is able to detect the different haemoglobin polymorphisms A, S, C and E, as well as G6PD polymorphisms B, A and A- based on PCR......-amplification followed by a hybridization step using sequence-specific oligonucleotide probes (SSOPs) specific for the SNP variants and quantified by ELISA. RESULTS: The SSOP-ELISA method was found to be specific, and compared well to the commonly used PCR-RFLP technique. Identical results were obtained in 98......% (haemoglobin) and 95% (G6PD) of the tested 90 field samples from a high-transmission area in Tanzania, which were used to validate the new technique. CONCLUSION: The simplicity and accuracy of the new methodology makes it suitable for application in settings where resources are limited. It would serve...

  3. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  4. An Adaptive Smoother for Counting Measurements

    International Nuclear Information System (INIS)

    Kondrasovs Vladimir; Coulon Romain; Normand Stephane

    2013-06-01

    Counting measurements associated with nuclear instruments are tricky to carry out due to the stochastic process of the radioactivity. Indeed events counting have to be processed and filtered in order to display a stable count rate value and to allow variations monitoring in the measured activity. Smoothers (as the moving average) are adjusted by a time constant defined as a compromise between stability and response time. A new approach has been developed and consists in improving the response time while maintaining count rate stability. It uses the combination of a smoother together with a detection filter. A memory of counting data is processed to calculate several count rate estimates using several integration times. These estimates are then sorted into the memory from short to long integration times. A measurement position, in terms of integration time, is then chosen into this memory after a detection test. An inhomogeneity into the Poisson counting process is detected by comparison between current position estimate and the other estimates contained into the memory in respect with the associated statistical variance calculated with homogeneous assumption. The measurement position (historical time) and the ability to forget an obsolete data or to keep in memory a useful data are managed using the detection test result. The proposed smoother is then an adaptive and a learning algorithm allowing an optimization of the response time while maintaining measurement counting stability and converging efficiently to the best counting estimate after an effective change in activity. This algorithm has also the specificity to be low recursive and thus easily embedded into DSP electronics based on FPGA or micro-controllers meeting 'real life' time requirements. (authors)

  5. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  6. Radiation Counting System Software Using Visual Basic

    International Nuclear Information System (INIS)

    Nanda Nagara; Didi Gayani

    2009-01-01

    It has been created a Gamma Radiation Counting System using interface card, which paired with Personal Computer (PC) and operated by the Visual Basic program. The program was set through varied menu selections such as ”Multi Counting” , ”Counting and Record” and ”View Data”. An interface card for data acquisition was formed by using AMD9513 components as a counter and timer which can be programmed. This counting system was tested and used in waste facility in PTNBR and the result is quite good. (author)

  7. Algorithm for counting large directed loops

    Energy Technology Data Exchange (ETDEWEB)

    Bianconi, Ginestra [Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Gulbahce, Natali [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, NM 87545 (United States)

    2008-06-06

    We derive a Belief-Propagation algorithm for counting large loops in a directed network. We evaluate the distribution of the number of small loops in a directed random network with given degree sequence. We apply the algorithm to a few characteristic directed networks of various network sizes and loop structures and compare the algorithm with exhaustive counting results when possible. The algorithm is adequate in estimating loop counts for large directed networks and can be used to compare the loop structure of directed networks and their randomized counterparts.

  8. Counts and colors of faint galaxies

    International Nuclear Information System (INIS)

    Kron, R.G.

    1980-01-01

    The color distribution of faint galaxies is an observational dimension which has not yet been fully exploited, despite the important constraints obtainable for galaxy evolution and cosmology. Number-magnitude counts alone contain very diluted information about the state of things because galaxies from a wide range in redshift contribute to the counts at each magnitude. The most-frequently-seen type of galaxy depends on the luminosity function and the relative proportions of galaxies of different spectral classes. The addition of color as a measured quantity can thus considerably sharpen the interpretation of galaxy counts since the apparent color depends on the redshift and rest-frame spectrum. (Auth.)

  9. A measurement technique for counting processes

    International Nuclear Information System (INIS)

    Cantoni, V.; Pavia Univ.; De Lotto, I.; Valenziano, F.

    1980-01-01

    A technique for the estimation of first and second order properties of a stationary counting process is presented here which uses standard instruments for analysis of a continuous stationary random signal. (orig.)

  10. Why calories count: from science to politics

    National Research Council Canada - National Science Library

    Nestle, Marion; Nesheim, Malden C

    2012-01-01

    .... They are also hard to understand. In Why Calories Count, Marion Nestle and Malden Nesheim explain in clear and accessible language what calories are and how they work, both biologically and politically...

  11. CoC Housing Inventory Count Reports

    Data.gov (United States)

    Department of Housing and Urban Development — Continuum of Care (CoC) Homeless Assistance Programs Housing Inventory Count Reports are a snapshot of a CoC’s housing inventory, available at the national and state...

  12. White Blood Cell Counts and Malaria

    National Research Council Canada - National Science Library

    McKenzie, F. E; Prudhomme, Wendy A; Magill, Alan J; Forney, J. R; Permpanich, Barnyen; Lucas, Carmen; Gasser, Jr., Robert A; Wongsrichanalai, Chansuda

    2005-01-01

    White blood cells (WBCs) were counted in 4697 individuals who presented to outpatient malaria clinics in Maesod, Tak Province, Thailand, and Iquitos, Peru, between 28 May and 28 August 1998 and between 17 May and 9 July 1999...

  13. VSRR Provisional Drug Overdose Death Counts

    Data.gov (United States)

    U.S. Department of Health & Human Services — This data contains provisional counts for drug overdose deaths based on a current flow of mortality data in the National Vital Statistics System. National...

  14. Low white blood cell count and cancer

    Science.gov (United States)

    ... gov/ency/patientinstructions/000675.htm Low white blood cell count and cancer To use the sharing features on this page, please enable JavaScript. White blood cells (WBCs) fight infections from bacteria, viruses, fungi, and ...

  15. Regression Models For Multivariate Count Data.

    Science.gov (United States)

    Zhang, Yiwen; Zhou, Hua; Zhou, Jin; Sun, Wei

    2017-01-01

    Data with multivariate count responses frequently occur in modern applications. The commonly used multinomial-logit model is limiting due to its restrictive mean-variance structure. For instance, analyzing count data from the recent RNA-seq technology by the multinomial-logit model leads to serious errors in hypothesis testing. The ubiquity of over-dispersion and complicated correlation structures among multivariate counts calls for more flexible regression models. In this article, we study some generalized linear models that incorporate various correlation structures among the counts. Current literature lacks a treatment of these models, partly due to the fact that they do not belong to the natural exponential family. We study the estimation, testing, and variable selection for these models in a unifying framework. The regression models are compared on both synthetic and real RNA-seq data.

  16. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  17. Atom counting with accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kutschera, Walter

    1995-01-01

    A brief review of the current status and some recent applications of accelerator mass spectrometry (AMS) are presented. Some connections to resonance ionization mass spectroscopy (RIS) as the alternate atom counting method are discussed

  18. Glucose-6-Phosphate Dehydrogenase Deficiency and Haemoglobin Drop after Sulphadoxine-Pyrimethamine Use for Intermittent Preventive Treatment of Malaria during Pregnancy in Ghana - A Cohort Study.

    Directory of Open Access Journals (Sweden)

    Ruth Owusu

    Full Text Available Sulphadoxine-Pyrimethamine (SP is still the only recommended antimalarial for use in intermittent preventive treatment of malaria during pregnancy (IPTp in some malaria endemic countries including Ghana. SP has the potential to cause acute haemolysis in G6PD deficient people resulting in significant haemoglobin (Hb drop but there is limited data on post SP-IPTp Hb drop. This study determined the difference, if any in proportions of women with significant acute haemoglobin drop between G6PD normal, partial deficient and full deficient women after SP-IPTp.Prospectively, 1518 pregnant women who received SP for IPTp as part of their normal antenatal care were enrolled. Their G6PD status were determined at enrollment followed by assessments on days 3, 7,14 and 28 to document any adverse effects and changes in post-IPTp haemoglobin (Hb levels. The three groups were comparable at baseline except for their mean Hb (10.3 g/dL for G6PD normal, 10.8 g/dL for G6PD partial deficient and 10.8 g/dL for G6PD full defect women.The prevalence of G6PD full defect was 2.3% and 17.0% for G6PD partial defect. There was no difference in the proportions with fractional Hb drop ≥ 20% as compared to their baseline value post SP-IPTp among the 3 groups on days 3, 7, 14. The G6PD full defect group had the highest median fractional drop at day 7. There was a weak negative correlation between G6PD activity and fractional Hb drop. There was no statistical difference between the three groups in the proportions of those who started the study with Hb ≥ 8g/dl whose Hb level subsequently fell below 8g/dl post-SP IPTp. No study participant required transfusion or hospitalization for severe anaemia.There was no significant difference between G6PD normal and deficient women in proportions with significant acute haemoglobin drop post SP-IPTp and lower G6PD enzyme activity was not strongly associated with significant acute drug-induced haemoglobin drop post SP-IPTp but a larger

  19. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  20. How to count an introduction to combinatorics

    CERN Document Server

    Allenby, RBJT

    2010-01-01

    What's It All About? What Is Combinatorics? Classic Problems What You Need to Know Are You Sitting Comfortably? Permutations and Combinations The Combinatorial Approach Permutations CombinationsApplications to Probability Problems The Multinomial Theorem Permutations and Cycles Occupancy Problems Counting the Solutions of Equations New Problems from Old A ""Reduction"" Theorem for the Stirling Numbers The Inclusion-Exclusion Principle Double Counting Derangements A Formula for the Stirling NumbersStirling and Catalan Numbers Stirling Numbers Permutations and Stirling Numbers Catalan Numbers Pa

  1. Accuracy and precision in activation analysis: counting

    International Nuclear Information System (INIS)

    Becker, D.A.

    1974-01-01

    Accuracy and precision in activation analysis was investigated with regard to counting of induced radioactivity. The various parameters discussed include configuration, positioning, density, homogeneity, intensity, radioisotopic purity, peak integration, and nuclear constants. Experimental results are presented for many of these parameters. The results obtained indicate that counting errors often contribute significantly to the inaccuracy and imprecision of analyses. The magnitude of these errors range from less than 1 percent to 10 percent or more in many cases

  2. Remote system for counting of nuclear pulses

    International Nuclear Information System (INIS)

    Nieves V, J.A.; Garcia H, J.M.; Aguilar B, M.A.

    1999-01-01

    In this work, it is describe technically the remote system for counting of nuclear pulses, an integral system of the project radiological monitoring in a petroleum distillation tower. The system acquires the counting of incident nuclear particles in a nuclear detector which process this information and send it in serial form, using the RS-485 toward a remote receiver, which can be a Personal computer or any other device capable to interpret the communication protocol. (Author)

  3. Altitude training and haemoglobin mass from the optimised carbon monoxide rebreathing method determined by a meta-analysis.

    Science.gov (United States)

    Gore, Christopher J; Sharpe, Ken; Garvican-Lewis, Laura A; Saunders, Philo U; Humberstone, Clare E; Robertson, Eileen Y; Wachsmuth, Nadine B; Clark, Sally A; McLean, Blake D; Friedmann-Bette, Birgit; Neya, Mitsuo; Pottgiesser, Torben; Schumacher, Yorck O; Schmidt, Walter F

    2013-12-01

    To characterise the time course of changes in haemoglobin mass (Hbmass) in response to altitude exposure. This meta-analysis uses raw data from 17 studies that used carbon monoxide rebreathing to determine Hbmass prealtitude, during altitude and postaltitude. Seven studies were classic altitude training, eight were live high train low (LHTL) and two mixed classic and LHTL. Separate linear-mixed models were fitted to the data from the 17 studies and the resultant estimates of the effects of altitude used in a random effects meta-analysis to obtain an overall estimate of the effect of altitude, with separate analyses during altitude and postaltitude. In addition, within-subject differences from the prealtitude phase for altitude participant and all the data on control participants were used to estimate the analytical SD. The 'true' between-subject response to altitude was estimated from the within-subject differences on altitude participants, between the prealtitude and during-altitude phases, together with the estimated analytical SD. During-altitude Hbmass was estimated to increase by ∼1.1%/100 h for LHTL and classic altitude. Postaltitude Hbmass was estimated to be 3.3% higher than prealtitude values for up to 20 days. The within-subject SD was constant at ∼2% for up to 7 days between observations, indicative of analytical error. A 95% prediction interval for the 'true' response of an athlete exposed to 300 h of altitude was estimated to be 1.1-6%. Camps as short as 2 weeks of classic and LHTL altitude will quite likely increase Hbmass and most athletes can expect benefit.

  4. Bridging Theory and Experiment to Address Structural Properties of Truncated Haemoglobins: Insights from Thermobifida fusca HbO.

    Science.gov (United States)

    Howes, Barry D; Boechi, Leonardo; Boffi, Alberto; Estrin, Dario E; Smulevich, Giulietta

    2015-01-01

    In this chapter, we will discuss the paradigmatic case of Thermobifida fusca (Tf-trHb) HbO in its ferrous and ferric states and its behaviour towards a battery of possible ligands. This choice was dictated by the fact that it has been one of the most extensively studied truncated haemoglobins, both in terms of spectroscopic and molecular dynamics studies. Tf-trHb typifies the structural properties of group II trHbs, as the active site is characterized by a highly polar distal environment in which TrpG8, TyrCD1, and TyrB10 provide three potential H-bond donors in the distal cavity capable of stabilizing the incoming ligands. The role of these residues in key topological positions, and their interplay with the iron-bound ligands, has been addressed in studies carried out on the CO, F(-), OH(-), CN(-), and HS(-) adducts formed with the wild-type protein and a combinatorial set of mutants, in which the distal polar residues, TrpG8, TyrCD1, and TyrB10, have been singly, doubly, or triply replaced by a Phe residue. In this context, such a complete analysis provides an excellent benchmark for the investigation of the relationship between protein structure and function, allowing one to translate physicochemical properties of the active site into the observed functional behaviour. Tf-trHb will be compared with other members of the group II trHbs and, more generally, with members of the other trHb subgroups. © 2015 Elsevier Ltd. All rights reserved.

  5. Crystallization and preliminary structural analysis of the giant haemoglobin from Glossoscolex paulistus at 3.2 Å

    Energy Technology Data Exchange (ETDEWEB)

    Bachega, J. F. R., E-mail: bachega@ursa.if.sc.usp.br; Bleicher, L.; Horjales, E. R. [Centro de Biotecnologia Molecular Estrutural, Instituto de Fisica de São Carlos, Universidade de São Paulo, São Carlos - SP, CEP 13566-590 (Brazil); Santiago, P. S. [Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos - SP, CEP 13566-590 (Brazil); Garratt, R. C. [Centro de Biotecnologia Molecular Estrutural, Instituto de Fisica de São Carlos, Universidade de São Paulo, São Carlos - SP, CEP 13566-590 (Brazil); Tabak, M., E-mail: bachega@ursa.if.sc.usp.br [Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos - SP, CEP 13566-590 (Brazil)

    2011-01-01

    Diffraction data to 3.2 Å from crystals of the 3.6 MDa erythrocruorin from a Brazilian earthworm represent the highest resolution reported to date for similar complexes. An unambiguous molecular replacement solution shows the particle to belong to the type I class. Glossoscolex paulistus is a free-living earthworm encountered in south-east Brazil. Its oxygen transport requirements are undertaken by a giant extracellular haemoglobin, or erythrocruorin (HbGp), which has an approximate molecular mass of 3.6 MDa and, by analogy with its homologue from Lumbricus terrestris (HbLt), is believed to be composed of a total of 180 polypeptide chains. In the present work the full 3.6 MDa particle in its cyanomet state was purified and crystallized using sodium citrate or PEG8000 as precipitant. The crystals contain one-quarter of the full particle in the asymmetric unit of the I222 cell and have parameters of a = 270.8 Å, b = 320.3 Å and c = 332.4 Å. Diffraction data were collected to 3.15 Å using synchrotron radiation on beamline X29A at the Brookhaven National Laboratory and represent the highest resolution data described to date for similar erythrocruorins. The structure was solved by molecular replacement using a search model corresponding to one-twelfth of its homologue from HbLt. This revealed that HbGp belongs to the type I class of erythrocruorins and provided an interpretable initial electron density map in which many features including the haem groups and disulfide bonds could be identified.

  6. Haemoglobin Fontainebleau (HBA2: c. 64G>C) in Oman: molecular and haematological characteristics and interaction with various haemoglobinopathies.

    Science.gov (United States)

    Daar, Shahina; Al Zadjali, Shoaib; Alkindi, Salam; Wali, Yasser; Al-Rawas, Abdulhakeem; Al-Haddabi, Humood; Al-Riyami, Arwa Z

    2018-04-01

    To describe the laboratory features of haemoglobin Fontainebleau (Hb FB) and its interactions with various α and β globin gene mutations in the Omani population. Over a period of 10 years, a total of 94 blood samples were suspected to have an α variant on HPLC at the Sultan Qaboos University Hospital, Muscat, Oman. Molecular testing was performed using PCR based techniques to define the variant and to analyse other interacting mutations in either α or β globin genes. Of 94 subjects, molecular analysis confirmed the Hb FB variant in 55 samples (38 non-cord and 17 cord blood). A total of 36/38 non-cord samples were heterozygous for the variant, while all 17 cord blood samples were heterozygotes. A total of 43/55 individuals had a concomitant α and/or β globin gene mutation. Hb FB is the the most common α variant in the Omani population. We report the different HPLC profiles of this variant that we observed, with and without other haemoglobinopathies in non-cord and cord blood samples. This is the first report describing the HPLC profiles of this α globin chain variant on 1 year follow-up testing of cord blood samples. With careful analysis by HPLC, it is possible not only to identify Hb FB but also to predict any concomitant α and/or β globin gene mutations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Malaria in Pregnancy Is a Predictor of Infant Haemoglobin Concentrations during the First Year of Life in Benin, West Africa.

    Directory of Open Access Journals (Sweden)

    Manfred Accrombessi

    Full Text Available Anaemia is an increasingly recognized health problem in Africa, particularly in infants and pregnant women. Although malaria is known to be the main risk factor of anaemia in both groups, the consequences of maternal factors, particularly malaria in pregnancy (MiP, on infant haemoglobin (Hb concentrations during the first months of life are still unclear.We followed-up a cohort of 1005 Beninese pregnant women from the beginning of pregnancy until delivery. A subsample composed of the first 400 offspring of these women were selected at birth and followed until the first year of life. Placental histology and blood smear at 1st clinical antenatal visit (ANC, 2nd ANC and delivery were used to assess malaria during pregnancy. Infant Hb concentrations were measured at birth, 6, 9 and 12 months of age. A mixed multi-level model was used to assess the association between MiP and infant Hb variations during the first 12 months of life.Placental malaria (difference mean [dm] = - 2.8 g/L, 95% CI [-5.3, -0.3], P = 0.03 and maternal peripheral parasitaemia at delivery (dm = - 4.6 g/L, 95% CI [-7.9, -1.3], P = 0.007 were the main maternal factors significantly associated with infant Hb concentrations during the first year of life. Poor maternal nutritional status and malaria infection during infancy were also significantly associated with a decrease in infant Hb.Antimalarial control and nutritional interventions before and during pregnancy should be reinforced to reduce specifically the incidence of infant anaemia, particularly in Sub-Saharan countries.

  8. Recursive algorithms for phylogenetic tree counting.

    Science.gov (United States)

    Gavryushkina, Alexandra; Welch, David; Drummond, Alexei J

    2013-10-28

    In Bayesian phylogenetic inference we are interested in distributions over a space of trees. The number of trees in a tree space is an important characteristic of the space and is useful for specifying prior distributions. When all samples come from the same time point and no prior information available on divergence times, the tree counting problem is easy. However, when fossil evidence is used in the inference to constrain the tree or data are sampled serially, new tree spaces arise and counting the number of trees is more difficult. We describe an algorithm that is polynomial in the number of sampled individuals for counting of resolutions of a constraint tree assuming that the number of constraints is fixed. We generalise this algorithm to counting resolutions of a fully ranked constraint tree. We describe a quadratic algorithm for counting the number of possible fully ranked trees on n sampled individuals. We introduce a new type of tree, called a fully ranked tree with sampled ancestors, and describe a cubic time algorithm for counting the number of such trees on n sampled individuals. These algorithms should be employed for Bayesian Markov chain Monte Carlo inference when fossil data are included or data are serially sampled.

  9. Preverbal and verbal counting and computation.

    Science.gov (United States)

    Gallistel, C R; Gelman, R

    1992-08-01

    We describe the preverbal system of counting and arithmetic reasoning revealed by experiments on numerical representations in animals. In this system, numerosities are represented by magnitudes, which are rapidly but inaccurately generated by the Meck and Church (1983) preverbal counting mechanism. We suggest the following. (1) The preverbal counting mechanism is the source of the implicit principles that guide the acquisition of verbal counting. (2) The preverbal system of arithmetic computation provides the framework for the assimilation of the verbal system. (3) Learning to count involves, in part, learning a mapping from the preverbal numerical magnitudes to the verbal and written number symbols and the inverse mappings from these symbols to the preverbal magnitudes. (4) Subitizing is the use of the preverbal counting process and the mapping from the resulting magnitudes to number words in order to generate rapidly the number words for small numerosities. (5) The retrieval of the number facts, which plays a central role in verbal computation, is mediated via the inverse mappings from verbal and written numbers to the preverbal magnitudes and the use of these magnitudes to find the appropriate cells in tabular arrangements of the answers. (6) This model of the fact retrieval process accounts for the salient features of the reaction time differences and error patterns revealed by experiments on mental arithmetic. (7) The application of verbal and written computational algorithms goes on in parallel with, and is to some extent guided by, preverbal computations, both in the child and in the adult.

  10. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  11. A report of a Hepatozoon canis infection in a dog with transmissible venereal tumour

    Directory of Open Access Journals (Sweden)

    Namakkal Rajamanickam Senthil

    2015-10-01

    Full Text Available In the present study, a case of a Hepatozoan canis infection in a dog with a sexually transmissible venereal tumour is reported. Haematological examination revealed marked decrease in haemoglobin, PCV and RBC counts and the blood smear revealed rouleaux formation of RBC, hypochromasia, leptocytes and neutrophilia. Neutrophils were parasitized with both non-nucleated and stained nucleated forms of H. canis. Serum biochemistry results showed elevated levels of alkaline phosphatise, whereas blood urea nitrogen, creatinine, total protein, albumin and globulin were in the normal range.

  12. Population genetic structure and phylogeographical pattern of a relict tree fern, Alsophila spinulosa (Cyatheaceae), inferred from cpDNA atpB- rbcL intergenic spacers.

    Science.gov (United States)

    Su, Yingjuan; Wang, Ting; Zheng, Bo; Jiang, Yu; Chen, Guopei; Gu, Hongya

    2004-11-01

    Sequences of chloroplast DNA (cpDNA) atpB- rbcL intergenic spacers of individuals of a tree fern species, Alsophila spinulosa, collected from ten relict populations distributed in the Hainan and Guangdong provinces, and the Guangxi Zhuang region in southern China, were determined. Sequence length varied from 724 bp to 731 bp, showing length polymorphism, and base composition was with high A+T content between 63.17% and 63.95%. Sequences were neutral in terms of evolution (Tajima's criterion D=-1.01899, P>0.10 and Fu and Li's test D*=-1.39008, P>0.10; F*=-1.49775, P>0.10). A total of 19 haplotypes were identified based on nucleotide variation. High levels of haplotype diversity (h=0.744) and nucleotide diversity (Dij=0.01130) were detected in A. spinulosa, probably associated with its long evolutionary history, which has allowed the accumulation of genetic variation within lineages. Both the minimum spanning network and neighbor-joining trees generated for haplotypes demonstrated that current populations of A. spinulosa existing in Hainan, Guangdong, and Guangxi were subdivided into two geographical groups. An analysis of molecular variance indicated that most of the genetic variation (93.49%, P<0.001) was partitioned among regions. Wright's isolation by distance model was not supported across extant populations. Reduced gene flow by the Qiongzhou Strait and inbreeding may result in the geographical subdivision between the Hainan and Guangdong + Guangxi populations (FST=0.95, Nm=0.03). Within each region, the star-like pattern of phylogeography of haplotypes implied a population expansion process during evolutionary history. Gene genealogies together with coalescent theory provided significant information for uncovering phylogeography of A. spinulosa.

  13. [Reference values of neonatal erythrocyte and leukocyte count in Bamako, Mali].

    Science.gov (United States)

    Diallo, Dapa Aly; Diawara, Faoumata; Guindo, Aldiouma; Touré, Moustaph; Traoré, Mamadou; Fofana, Aïssata Traoré; Dembélé, Albdoul K; Guindo, Agnès; Diallo, Yacouba Lazare; Diallo, Oumahane; Baraika, Ag Mohamed; Dolo, Amadou Ingré

    2013-01-01

    Reference values for blood cell count are not established at birth in Mali. This study aimed to determine reference values for erythrocyte and leukocyte at birth in Bamako. Blood was collected from the umbilical cord immediately following its clamping and studied for complete blood cell count in 481 newborns with a birth weight > 2500g, Apgar score ≤ 7 at 5 or 10 minutes, without abnormal hemoglobin mutations and whose mothers were willing in Bamako, Mali. Other than the median and mean values, 2.5 and 97.5 percentiles were calculated. The findings suggest that the normal reference values following a timely clamping of the umbilical cord were (mean ± 1SD and range): RBC = 4,00 ± 0,46.1012/L (3,13 - 4,89), Hb = 14,12 ± 1,49 g/dL (11,20 - 17,00), Hct = 40,27 ± 4,71% (31,62 - 50,18), MCV = 101 ± 5 fl (91 - 112), MCHC = 35,37 ± 2,16 pg/cellule (30,70 - 39,59), MCH = 35,06 ± 0,93 g/dL (33,40 - 36,90), RDW = 17,79 ± 7,33% (15,50 - 20,39), Reticulocytes (109/L) = 133,081 ± 29,95 (66,62 - 200,86), GB (109/L) = 13,24 ± 7,23 (7,20 - 23,70), PMN (109/L) = 7,16 ± 4,70 (3,07 - 14,22), PME (109/L) = 0,28 ± 0,26 (0 - 0,98), PMB(109/L) = 0,05 ± 0,09 (0 - 0,31), Lymphocytes (109/L) = 4,49 ± 2,45 (1,96 - 9,42), Monocytes (10 9 /L) = 1,06 ± 0,73 (0,21 - 2,54), myelocytes = 1.43 ± 1.51%, erythroblasts = 4.52 ± 7.83%. It should be noted that male babies had a lower neutrophil count than female newborns. By taking into account these results when interpreting the blood cell count in Malian newborn infants, costly misdiagnoses should be considerably decreased in a population struggling with low incomes. Le comitée de rédaction se réserve le droit de revoyer aux auteurs avant toute soumission à l'avis des lecteurs les manuscrits qui ne seraient pas conformes à ces modalités de présentation. En outre il leur conseille de sonserver un examplaire du manuscrit, des figures et des tableaux.

  14. Photon counting and fluctuation of molecular movement

    International Nuclear Information System (INIS)

    Inohara, Koichi

    1978-01-01

    The direct measurement of the fluctuation of molecular motions, which provides with useful information on the molecular movement, was conducted by introducing photon counting method. The utilization of photon counting makes it possible to treat the molecular system consisting of a small number of molecules like a radioisotope in the detection of a small number of atoms, which are significant in biological systems. This method is based on counting the number of photons of the definite polarization emitted in a definite time interval from the fluorescent molecules excited by pulsed light, which are bound to the marked large molecules found in a definite spatial region. Using the probability of finding a number of molecules oriented in a definite direction in the definite spatial region, the probability of counting a number of photons in a definite time interval can be calculated. Thus the measurable count rate of photons can be related with the fluctuation of molecular movement. The measurement was carried out under the condition, in which the probability of the simultaneous arrival of more than two photons at a detector is less than 1/100. As the experimental results, the resolving power of photon-counting apparatus, the frequency distribution of the number of photons of some definite polarization counted for 1 nanosecond are shown. In the solution, the variance of the number of molecules of 500 on the average is 1200, which was estimated from the experimental data by assuming normal distribution. This departure from the Poisson distribution means that a certain correlation does exist in molecular movement. In solid solution, no significant deviation was observed. The correlation existing in molecular movement can be expressed in terms of the fluctuation of the number of molecules. (Nakai, Y.)

  15. Phylogeny of Salsoleae s.l. (Chenopodiaceae) based on DNA sequence data from ITS, psbB-psbH, and rbcL, with emphasis on taxa of northwestern China

    Science.gov (United States)

    Zhi-Bin Wen; Ming-Li Zhang; Ge-Lin Zhu; Stewart C. Sanderson

    2010-01-01

    To reconstruct phylogeny and verify the monophyly of major subgroups, a total of 52 species representing almost all species of Salsoleae s.l. in China were sampled, with analysis based on three molecular markers (nrDNA ITS, cpDNA psbB-psbH and rbcL), using maximum parsimony, maximum likelihood, and Bayesian inference methods. Our molecular evidence provides strong...

  16. Noun Countability; Count Nouns and Non-count Nouns, What are the Syntactic Differences Between them?

    Directory of Open Access Journals (Sweden)

    Azhar A. Alkazwini

    2016-11-01

    Full Text Available Words that function as the subjects of verbs, objects of verbs or prepositions and which can have a plural form and possessive ending are known as nouns. They are described as referring to persons, places, things, states, or qualities and might also be used as an attributive modifier. In this paper, classes and subclasses of nouns shall be presented, then, noun countability branching into count and non-count nous shall be discussed. A number of present examples illustrating differences between count and non-count nouns and this includes determiner-head-co-occurrence restrictions of number, subject-verb agreement, in addition to some exceptions to this agreement rule shall be discussed. Also, the lexically inherent number in nouns and how inherently plural nouns are classified in terms of (+/- count are illustrated. This research will discuss partitive construction of count and non-count nouns, nouns as attributive modifier and, finally, conclude with the fact that there are syntactic difference between count and non-count in the English Language.

  17. Benjamin Thompson, Count Rumford Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    1967-01-01

    Men of Physics: Benjamin Thompson - Count Rumford: Count Rumford on the Nature of Heat covers the significant contributions of Count Rumford in the fields of physics. Count Rumford was born with the name Benjamin Thompson on March 23, 1753, in Woburn, Massachusetts. This book is composed of two parts encompassing 11 chapters, and begins with a presentation of Benjamin Thompson's biography and his interest in physics, particularly as an advocate of an """"anti-caloric"""" theory of heat. The subsequent chapters are devoted to his many discoveries that profoundly affected the physical thought

  18. IMPACT OF 10 SESSIONS OF WHOLE BODY CRYOSTIMULATION ON AEROBIC AND ANAEROBIC CAPACITY AND ON SELECTED BLOOD COUNT PARAMETERS

    Directory of Open Access Journals (Sweden)

    Tomasz Dybek

    2012-01-01

    Full Text Available The systemic effect of low temperature suggests that sessions in a cryogenic chamber might improve athletes’ capacity as a standard element of training. Therefore the authors decided to evaluate the impact of 10 sessions of whole body cryostimulation (WBCT on aerobic and anaerobic efficiency as well as on selected blood count parameters. The study group included 32 volunteers – 16 women and 16 men. The volunteers underwent 10 sessions of WBCT in a cryogenic chamber. Blood samples (RBC, WBC, PLT, HGB, HCT were taken, and aerobic and anaerobic efficiency and lactate concentration in capillary blood were measured before the first session and one day after the last one. No significant differences were observed in values of aerobic capacity after 10 sessions of WBCT. There was a rising trend in men and a declining trend in women. The lactate concentration did not differ significantly before and after WBCT. A slight rise in aerobic and anaerobic threshold was observed in men, while in women the values slightly fell. The Wingate test showed no significant differences in results before and after cryostimulation. Only the TOBT was significantly shorter in men (6.12±1.49 vs 3.79±1.14 s. The WBCT sessions resulted in a significant rise of the haematological parameters both in women and men, excluding HCT, which showed a statistically insignificant rise. Ten sessions of whole body cryostimulation did not affect aerobic or anaerobic capacity in the tested group, although it improved the blood count parameters.

  19. Studies on the chronological alterations of blood counts on the radiological technicians at health centers in Japan (1957 - 1975)

    International Nuclear Information System (INIS)

    Endo, Kouichi; Ishizaka, Masatsuna

    1977-01-01

    From the nine health surveys made on clinical radiation technicians working at health centers during the 18 years from 1957 to 1975, 679 technicians on whom blood examinations were made for not less than ten consecutive years were sampled to investigate for chronological alterations in their blood parameters. The radiation protective means at the health centers have made rapid progress ever since the atomic bomb experiment in 1954, and the dose of exposure to radiation then began to decrease. On the other hand, it was in about 1960 that the measurement of individual exposure doses began to be made on 60% of all the technicians. Chronological alterations in the average blood counts of these technicians under the abovementioned situation were such that RBC and hemoglobin level continued to increase from 1963 until about 1967, but then began to decrease, and that WBC was as low as 5,883/mm 3 in 1957, but tended to increase though slightly at each of the subsequent surveys, and was increased to 6,570/mm 3 in 1975, that is, WBC has been approaching the normal count of 6,774/mm 3 in the Japanese, with a significant difference at a not more than 1% level of significance in each survey year. For the purpose of preventing radiation hazard, further efforts should be made to protect the technicians from exposure to radiation and to control their health. (auth.)

  20. Blood Count Tests: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish WBC count (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Blood Count Tests ... WBC count Show More Show Less Related Health Topics Bleeding Disorders Blood Laboratory Tests National Institutes of ...

  1. The nutritional status affects the complete blood count of goats experimentally infected with Haemonchus contortus.

    Science.gov (United States)

    Cériac, S; Jayles, C; Arquet, R; Feuillet, D; Félicité, Y; Archimède, H; Bambou, J-C

    2017-11-09

    Gastrointestinal nematode (GIN) remains the most important pathogenic constraint of small ruminant production worldwide. The improvement of the host immune response against GIN though breeding for improved animal resistance, vaccination and nutritional supplementation appear as very promising methods. The objective of this study was to investigate the effect of four nutritional status differing in protein and energy levels (Hay: 5.1 MJ/Kg of dry matter (DM) and 7.6% of crude protein (CP), Ban: 8.3 MJ/Kg of DM and 7.5% of CP, Soy: 7.6 MJ/Kg of DM and 17.3% of CP, BS: 12.7 MJ/Kg of DM and 7.4% of CP) on the haematological disturbances due to Haemonchus contortus infection in Creole kid goats. No significant effect of the nutritional status was observed for faecal egg count (FEC) but the experimental infection induced haematological disturbances whose intensity and lengthening were dependent on the nutritional status. A transient marked regenerative macrocytic hypochromic anaemia as revealed by a decrease of packed cell volume (PCV), red blood cells (RBC) and hemoglobin and an increase of reticulocytes was observed in all infected groups except Hay. In this latter, the anaemia settled until the end of the experiment. Furthermore, H. contortus induced a thrombocytopenia significantly more pronounced in the group under the lowest nutritional status in term of protein (Hay and Ban). A principal component analysis revealed that the variables that discriminated the nutritional status were the average daily gain (ADG) and the PCV, considered as measures of the level of resilience to H. contortus infection. Moreover, the variables that discriminated infected and non-infected animals were mostly related to the biology of RBC (i.e. size and hemoglobin content) and they were correlated with FEC. The severity and the lengthening of the regenerative anaemia and the thrombocytopenia induced by H. contortus have been affected by the nutritional status. The protein enriched

  2. It counts who counts: an experimental evaluation of the importance of observer effects on spotlight count estimates

    DEFF Research Database (Denmark)

    Sunde, Peter; Jessen, Lonnie

    2013-01-01

    observers with respect to their ability to detect and estimate distance to realistic animal silhouettes at different distances. Detection probabilities were higher for observers experienced in spotlighting mammals than for inexperienced observers, higher for observers with a hunting background compared...... with non-hunters and decreased as function of age but were independent of sex or educational background. If observer-specific detection probabilities were applied to real counting routes, point count estimates from inexperienced observers without a hunting background would only be 43 % (95 % CI, 39...

  3. Protecting count queries in study design.

    Science.gov (United States)

    Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A

    2012-01-01

    Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.

  4. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  5. The influence of carbon monoxide bolus on the measurement of total haemoglobin mass using the optimized CO-rebreathing method

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M; Ingham, S A; Fudge, B W

    2014-01-01

    The optimized carbon monoxide (CO) rebreathing method (oCOR-method) is routinely used to measure total haemoglobin mass (tHbmass). The tHbmass measure is subject to a test-retest typical error of ∼2%, mostly from the precision of carboxyhaemoglobin (HbCO) measurement. We hypothesized that tHbmass would be robust to differences in the bolus of CO administered during the oCOR-method. Twelve participants (ten males and two females; age 27 ± 6 yr, height 177 ± 11 cm and mass 73.9 ± 12.1 kg) completed the oCOR-method on four occasions. Different bolus of CO were administered (LOW: 0.6 ml kg −1 ; MED 1 : 1.0 ml kg −1  and HIGH: 1.4 ml kg −1 ); to determine the reliability of MED 1 , a second trial was conducted (MED 2 ). tHbmass was found to be significantly less from the HIGH CO bolus (776 ± 148 g) when compared to the LOW CO (791 ± 149 g) or MED 1  CO (788 ± 149 g) trials. MED 2  CO was 785 ± 150 g. The measurement of tHbmass is repeatable to within 0.8%, but a small and notable difference was seen when using a HIGH CO bolus (1.4 to 1.9% less), potentially due to differences in CO uptake kinetics. Previously, an improved precision of the oCOR-method was thought to require a higher bolus of CO (i.e. larger ▵%HbCO), as commercial hemoximeters only estimate %HbCO levels to a single decimal place (usually ± 0.1%). With the new hemoximeter used in this study, a bolus of 1.0 ml kg −1  allows adequate precision with acceptable safety. (note)

  6. Defining a glycated haemoglobin (HbA1c) level that predicts increased risk of penile implant infection.

    Science.gov (United States)

    Habous, Mohamad; Tal, Raanan; Tealab, Alaa; Soliman, Tarek; Nassar, Mohammed; Mekawi, Zenhom; Mahmoud, Saad; Abdelwahab, Osama; Elkhouly, Mohamed; Kamr, Hatem; Remeah, Abdallah; Binsaleh, Saleh; Ralph, David; Mulhall, John

    2018-02-01

    To re-evaluate the role of diabetes mellitus (DM) as a risk factor for penile implant infection by exploring the association between glycated haemoglobin (HbA1c) levels and penile implant infection rates and to define a threshold value that predicts implant infection. We conducted a multicentre prospective study including all patients undergoing penile implant surgery between 2009 and 2015. Preoperative, perioperative and postoperative management were identical for the entire cohort. Univariate analysis was performed to define predictors of implant infection. The HbA1c levels were analysed as continuous variables and sequential analysis was conducted using 0.5% increments to define a threshold level predicting implant infection. Multivariable analysis was performed with the following factors entered in the model: DM, HbA1C level, patient age, implant type, number of vascular risk factors (VRFs), presence of Peyronie's disease (PD), body mass index (BMI), and surgeon volume. A receiver operating characteristic (ROC) curve was generated to define the optimal HbA1C threshold for infection prediction. In all, 902 implant procedures were performed over the study period. The mean patient age was 56.6 years. The mean HbA1c level was 8.0%, with 81% of men having a HbA1c level of >6%. In all, 685 (76%) implants were malleable and 217 (24%) were inflatable devices; 302 (33.5%) patients also had a diagnosis of PD. The overall infection rate was 8.9% (80/902). Patients who had implant infection had significantly higher mean HbA1c levels, 9.5% vs 7.8% (P HbA1c level, we found infection rates were: 1.3% with HbA1c level of 9.5% (P HbA1c level, whilst a high-volume surgeon had a protective effect and was associated with a reduced infection risk. Using ROC analysis, we determined that a HbA1c threshold level of 8.5% predicted infection with a sensitivity of 80% and a specificity of 65%. Uncontrolled DM is associated with increased risk of infection after penile implant surgery

  7. Haemoglobin changes and risk of anaemia following treatment for uncomplicated falciparum malaria in sub-Saharan Africa.

    Science.gov (United States)

    Zwang, Julien; D'Alessandro, Umberto; Ndiaye, Jean-Louis; Djimdé, Abdoulaye A; Dorsey, Grant; Mårtensson, Andreas A; Karema, Corine; Olliaro, Piero L

    2017-06-23

    Anaemia is common in malaria. It is important to quantitate the risk of anaemia and to distinguish factors related to the natural history of disease from potential drug toxicity. Individual-patient data analysis based on nine randomized controlled trials of treatments of uncomplicated falciparum malaria from 13 sub-Saharan African countries. Risk factors for reduced haemoglobin (Hb) concentrations and anaemia on presentation and after treatment were analysed using mixed effect models. Eight thousand eight hundred ninety-seven patients (77.0% <5 years-old) followed-up through 28 days treated with artemisinin combination therapy (ACT, 90%, n = 7968) or non-ACT. At baseline, under 5's had the highest risk of anaemia (77.6% vs. 32.8%) and higher parasitaemia (43,938 μl) than older subjects (2784 μl). Baseline anaemia increased the risk of parasitological recurrence. Hb began to fall after treatment start. In under 5's the estimated nadir was ~35 h (range 29-48), with a drop of -12.8% from baseline (from 9.8 g/dl to 8.7 g/dl, p = 0.001); in under 15's, the mean Hb decline between day 0-3 was -4.7% (from 9.4 to 9.0 g/dl, p = 0.001). The degree of Hb loss was greater in patients with high pre-treatment Hb and parasitaemia and with slower parasite reduction rates, and was unrelated to age. Subsequently, Hb increased linearly (+0.6%/day) until day 28, to reach +13.8% compared to baseline. Severe anaemia (<5 g/dl, 2 per 1000 patients) was transient and all patients recovered after day 14, except one case of very severe anaemia associated with parasite recurrence at day 28. There was no systematic difference in Hb concentrations between treatments and no case of delayed anaemia. On presentation with acute malaria young children with high parasitaemia have the highest risk of anaemia. The majority of patients experience a drop in Hb while on treatment as early as day 1-2, followed by a linear increase through follow-up. The degree of the early Hb dip is

  8. BMI in relation to sperm count

    DEFF Research Database (Denmark)

    Sermondade, N; Faure, C; Fezeu, L

    2013-01-01

    BACKGROUND The global obesity epidemic has paralleled a decrease in semen quality. Yet, the association between obesity and sperm parameters remains controversial. The purpose of this report was to update the evidence on the association between BMI and sperm count through a systematic review...... with meta-analysis. METHODS A systematic review of available literature (with no language restriction) was performed to investigate the impact of BMI on sperm count. Relevant studies published until June 2012 were identified from a Pubmed and EMBASE search. We also included unpublished data (n = 717 men...... studies were included in the meta-analysis, resulting in a sample of 13 077 men from the general population and attending fertility clinics. Data were stratified according to the total sperm count as normozoospermia, oligozoospermia and azoospermia. Standardized weighted mean differences in sperm...

  9. Multiple sample, radioactive particle counting apparatus

    International Nuclear Information System (INIS)

    Reddy, R.R.V.; Kelso, D.M.

    1978-01-01

    An apparatus is described for determining the respective radioactive particle sample count being emitted from radioactive particle containing samples. It includes means for modulating the information on the radioactive particles being emitted from the samples, coded detecting means for sequentially detecting different respective coded combinations of the radioactive particles emitted from more than one but less than all of the samples, and processing the modulated information to derive the sample count for each sample. It includes a single light emitting crystal next to a number of samples, an encoder belt sequentially movable between the crystal and the samples. The encoder belt has a coded array of apertures to provide corresponding modulated light pulses from the crystal, and a photomultiplier tube to convert the modulated light pulses to decodable electrical signals for deriving the respective sample count

  10. CERN_DxCTA counting mode chip

    CERN Document Server

    Moraes, D; Nygård, E

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e−, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  11. CERNDxCTA counting mode chip

    International Nuclear Information System (INIS)

    Moraes, D.; Kaplon, J.; Nygard, E.

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e - , for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors

  12. Detection limits for radioanalytical counting techniques

    International Nuclear Information System (INIS)

    Hartwell, J.K.

    1975-06-01

    In low-level radioanalysis it is usually necessary to test the sample net counts against some ''Critical Level'' in order to determine if a given result indicates detection. This is an interpretive review of the work by Nicholson (1963), Currie (1968) and Gilbert (1974). Nicholson's evaluation of three different computational formulas for estimation of the ''Critical Level'' is discussed. The details of Nicholson's evaluation are presented along with a basic discussion of the testing procedures used. Recommendations are presented for calculation of confidence intervals, for reporting of analytical results, and for extension of the derived formula to more complex cases such as multiple background counts, multiple use of a single background count, and gamma spectrometric analysis

  13. Effects of plutonium redistribution on lung counting

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1976-01-01

    Early counts of Pu deposition in lungs will tend to overestimate lung contents since calibrations are performed with a uniform distribution and since a more favorable geometry exists in contaminated subjects because the activity is closer to the periphery of the lungs. Although the concentration into the outer regions of the lungs continues as evidenced by the autopsy studies, the counts performed by L X-rays will probably underestimate the lung content; because, simplistically, the geometry several years after exposure consists of a spherical shell with a point of activity in the center. This point of activity represents concentration in the lymph nodes from which the 60 keV gamma of 241 Am will be counted, but from which few of the L X-rays will be counted (this is an example of interorgan distribution). When a correction is made to the L X-ray intensity, the lymph node contribution will tend to increase the amount subtracted while correcting for 241 Am X-rays. It is doubtful that the relative increase in X-ray intensity by concentration in the pleural and sub-pleural regions will compensate for this effect. This will make the plutonium burden disappear while the 241 Am can still be detected. This effect has been observed in a case where counts with an intraesophageal probe indicated a substantial lymph node burden. In order to improve the accuracy of in vivo plutonium measurements, an improved understanding of pulmonary distribution and of distribution effects on in vivo counting are required

  14. INFLUENCIA DE LA CARGA ORGÁNICA SOBRE LA EFICIENCIA DE REACTORES RBC DE TRES ETAPAS EN EL TRATAMIENTO DE UN EFLUENTE INDUSTRIAL SINTÉTICO

    Directory of Open Access Journals (Sweden)

    Elisabeth Behling de Calmón

    2012-01-01

    Full Text Available El presente artículo incluye el estudio de la influencia de la carga orgánica (CO sobre la eficiencia de reactores biológicos rotativos de contacto (RBC, aerobios de tres etapas, al tratar un efluente industrial sintético, con la finalidad de establecer la adecuación del efluente final con respecto a los límites de descarga establecidos en la normativa de Venezuela. Durante la experimentación, se evaluaron pH, alcalinidad total, oxígeno disuelto, demanda biológica de oxígeno (DBO, demanda química de oxígeno (DQO, sólidos suspendidos totales (SST, nitrógeno total Kjeldahl (NTK, NH 4 + , NO 2 - y NO 3 - , de acuerdo con los métodos estándares. La variación de la CO aplicada se obtuvo mediante modificación del tiempo de retención hidráulico (TRH, (24, 12 y 6 h, y se mantuvo constante la DQO de entrada (influente sintético de sacarosa+ urea. La mayor eficiencia de remoción de DQO se obtuvo para un CO global de 11,68 gDQO/m 2 .d (96,25%; TRH=12 h. Para los TRH 24 y 12 h, la eficiencia de remoción global de N-total fue de 66,92 y 62,95%, respectivamente. La mayor remoción de C y de N se obtuvo en la primera etapa de los reactores y se logró cumplir con el límite venezolano permisible de descarga para DQO (<350 mg/L. La posible ocurrencia del proceso de nitrificación repercutió sobre el aumento de las concentraciones de nitrógeno inorgánico en el efluente final.

  15. Targeting, Monitoring and Effect of Oral Iron Therapy on Haemoglobin Levels in Older Patients Discharged to Primary Care from Inpatient Rehabilitation: A Cohort Study Using Routinely Collected Data.

    Science.gov (United States)

    Thomson, Zach; Hands, Katherine J; Witham, Miles D

    2016-08-01

    Oral iron is commonly prescribed to older patients with suspected or confirmed iron-deficiency anaemia; however, few studies have examined the effectiveness of oral iron therapy in the real world in this population. We therefore determined the prevalence of iron deficiency in older people prescribed oral iron, examined the response mounted to therapy and ascertained predictors of response to oral iron. We analysed a routinely collected, linked dataset from older patients who had undergone inpatient rehabilitation between 1999 and 2011. An initial analysis examined patients within this cohort who were prescribed iron after rehabilitation and derived three groups based upon their ferritin and transferrin indices: probably, possibly and not iron deficient. A second analysis compared pre- and post-treatment haemoglobin to determine the degree of response to iron therapy across each category of deficiency. Finally, patient demographics, linked biochemistry data and comorbid disease based on International Classification of Disease (ICD-10) codes from previous hospital admissions were used in regression modelling to evaluate factors affecting response to therapy. A total of 490 patients were prescribed oral iron within 90 days of rehabilitation discharge. Of these, 413 (84 %) had iron indices performed; 94 (23 %) were possibly deficient, 224 (54 %) were probably deficient, and 95 (23 %) were not deficient. Of the 490 patients, 360 had both pre- and post-treatment haemoglobin data and iron indices; probably deficient patients mounted a slightly greater response to oral iron (17 vs. 12 g/L for not deficient; p < 0.05). Only pre-treatment haemoglobin, mean cell volume and lower gastrointestinal pathology were significant predictors of a response to oral iron therapy. Notably, acid-suppressant use was not a predictor of response. We conclude that many older patients are exposed to oral iron without good evidence of either iron deficiency or a significant response to

  16. Diagnostic applications of newborn screening for α-thalassaemias, haemoglobins E and H disorders using isoelectric focusing on dry blood spots.

    Science.gov (United States)

    Jindatanmanusan, Punyanuch; Riolueang, Suchada; Glomglao, Waraporn; Sukontharangsri, Yaowapa; Chamnanvanakij, Sangkae; Torcharus, Kitti; Viprakasit, Vip

    2014-03-01

    Neonatal screening for haemoglobin (Hb) disorders is a standard of care in several developed countries with the main objective to detect Hb S. Such practice has not been established in Thailand where α-thalassaemia and haemoglobin E (Hb E) are highly prevalent. Early identification of thalassaemias could be helpful and strengthen the programme for prevention and control for severe thalassaemias. Data from isoelectric focusing (IEF) and Isoscan® for detecting types and amount (%) of each haemoglobin in 350 newborn's dried blood spots were analysed and compared with the comprehensive genotype analysis by DNA studies as a gold standard. Based on genetic profiles, there were 10 different categories: (1) normal (n = 227), (2) α(+)-thalassaemia trait (n = 14), (3) α(0)-thalassaemia trait (n = 13), (4) β(0)-thalassaemia trait (n = 7), (5) Hb E trait (n = 72), (6) Hb E trait with α(0)-thalassaemia or homozygous α(+)-thalassaemia (n = 5), (7) Hb E trait with α(+)-thalassaemia trait (n = 5), (8) homozygous Hb E (n = 3), (9) homozygous Hb E with α(0)-thalassaemia trait (n = 1) and (10) Hb H disease (n = 3). The presence of Hb Bart's and Hb E were used to identify cases with α-thalassaemia and Hb E, respectively. We set 0.25% of Hb Bart's and 1.5% of Hb E as a cut-off level to detect α(+)-thalassaemia trait (sensitivity 92.86% and specificity 74.0%) and Hb E trait with 100% of both sensitivity and specificity for IEF diagnosis. Although molecular diagnosis seems to be better for definitive diagnosis of thalassaemia syndromes at birth, however, using our reference range described herein, IEF can be applied in a resource-limiting setting with acceptable reliability.

  17. Count-to-count time interval distribution analysis in a fast reactor

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.

    1973-01-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs

  18. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    1974-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers which give homogeneous monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous monophasic-appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  19. Counting dyons in N=4 string theory

    CERN Document Server

    Dijkgraaf, R; Verlinde, Herman L

    1997-01-01

    We present a microscopic index formula for the degeneracy of dyons in four-dimensional N=4 string theory. This counting formula is manifestly symmetric under the duality group, and its asymptotic growth reproduces the macroscopic Bekenstein-Hawking entropy. We give a derivation of this result in terms of the type II five-brane compactified on K3, by assuming that its fluctuations are described by a closed string theory on its world-volume. We find that the degeneracies are given in terms of the denominator of a generalized super Kac-Moody algebra. We also discuss the correspondence of this result with the counting of D-brane states.

  20. Isospectral discrete and quantum graphs with the same flip counts and nodal counts

    Science.gov (United States)

    Juul, Jonas S.; Joyner, Christopher H.

    2018-06-01

    The existence of non-isomorphic graphs which share the same Laplace spectrum (to be referred to as isospectral graphs) leads naturally to the following question: what additional information is required in order to resolve isospectral graphs? It was suggested by Band, Shapira and Smilansky that this might be achieved by either counting the number of nodal domains or the number of times the eigenfunctions change sign (the so-called flip count) (Band et al 2006 J. Phys. A: Math. Gen. 39 13999–4014 Band and Smilansky 2007 Eur. Phys. J. Spec. Top. 145 171–9). Recent examples of (discrete) isospectral graphs with the same flip count and nodal count have been constructed by Ammann by utilising Godsil–McKay switching (Ammann private communication). Here, we provide a simple alternative mechanism that produces systematic examples of both discrete and quantum isospectral graphs with the same flip and nodal counts.

  1. Meat and cancer: haemoglobin and haemin in a low-calcium diet promote colorectal carcinogenesis at the aberrant crypt stage in rats

    Science.gov (United States)

    Pierre, Fabrice; Taché, Sylviane; Petit, Claude R; Van Der Meer, Roelof; Corpet, Denis E

    2003-01-01

    High intake of red meat, but not of white meat, is associated with an increased risk of colon cancer. However, red meat does not promote cancer in rodents. Haemin, added to low-calcium diets, increases colonic proliferation, and haemoglobin, added to high-fat diets, increases the colon tumour incidence in rats, an effect possibly due to peroxyl radicals. We thus speculated that haem might be the promoting agent in meat, and that prevention strategies could use calcium and antioxidants. These hypotheses were tested in rats at the aberrant crypt foci (ACF) stage at 100 days. F344 rats (n=124) were given an injection of azoxymethane and were then randomised to 11 groups fed with low-calcium (20μmol/g) AIN76-based diets, containing 5% safflower oil. Haemin (0.25, 0.5 and 1.5μmol/g) or haemoglobin (1.5 and 3 μmol haem/g) was added to five experimental diets, compared to a control diet without haem. Three other high-haemin diets (1.5μmol/g) were supplemented with calcium (250μmol/g), antioxidant butylated hydroxyanisole and rutin (0.05% each), and olive oil, which replaced safflower oil. Faecal water was assayed for lipid peroxidation by thiobarbituric acid reactive substances (TBARs) test, and for cytolytic activity. Haemin strikingly increased the ACF size, dose-dependently, from 2.6 to 11.4 crypts/ACF (all p<0.001). The high-haemin diet also increased the number of ACF per colon (p<0.001). Promotion was associated with increased faecal water TBARs and cytotoxicity. Calcium, olive oil, and antioxidants each inhibited the haemin-induced ACF promotion, and normalised the faecal TBARs and cytotoxicity. The haemoglobin diets increased the number of ACF and faecal TBARs, but not the ACF size or the faecal cytotoxicity. In conclusion, dietary haemin is the most potent known ACF promoter. Haemoglobin is also a potent promoter of colorectal carcinogenesis. The results suggest that myoglobin in red meat could promote colon cancer. Diets high in calcium, or in oxidation

  2. Effect of supplements: Probiotics and probiotic plus honey on blood cell counts and serum IgA in patients receiving pelvic radiotherapy

    Directory of Open Access Journals (Sweden)

    Hajar-Alsadat Mansouri-Tehrani

    2015-01-01

    Full Text Available Background: Radiotherapy is frequently used in treatment approaches of pelvic malignancies. Nevertheless, it has some known systemic effects on blood cells and the immune system that possibly results in their susceptibility to infection. Probiotics are live microbial food ingredients that provide a health advantage to the consumer. Honey has prebiotic properties. The aim of this clinical trial was to investigate probable effects of probiotic or probiotics plus honey on blood cell counts and serum IgA levels in patients receiving pelvic radiotherapy. Materials and Methods: Sixty-seven adult patients with pelvic cancer were enrolled. Patients were randomized to receive either: (1 Probiotic capsules (including: Lactobacillus casei, Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus bulgaricus, Bifidobacterium breve, Bifidobacterium longum, and Streptococcus thermophiles (n = 22, (2 probiotic capsules plus honey (n = 21 or (3 placebo capsules (n = 24 all for 6 weeks. Blood and serum samples were collected for one week before radiotherapy and 24-72 h after the end of radiotherapy. Results: White blood cells (WBC, red blood cells (RBC, platelet counts, and serum IgA level were not significantly changed in patients taking probiotic (alone or plus honey during pelvic radiotherapy. The mean decrease in RBC count was 0.52, 0.18, and 0.23 × 10 6 cells/μL, WBC count was 2.3, 1.21, and 1.34 × 10 3 cells/μL and platelet count was, 57.6, 53.3, and 66.35 × 10 3 cells/μL for the probiotic, probiotic plus honey, and placebo groups, respectively. The mean decrease of serum IgA was 22.53, 29.94, and 40.73 mg/dL for the probiotic, probiotic plus honey, and placebo groups, respectively. Conclusion: The observed nonsignificant effect of probiotics may be in favor of local effects of this product in the gut rather than systemic effects, however, as a trend toward a benefit was indicated, further studies are necessary in order to extract effects of

  3. Effect of supplements: Probiotics and probiotic plus honey on blood cell counts and serum IgA in patients receiving pelvic radiotherapy.

    Science.gov (United States)

    Mansouri-Tehrani, Hajar-Alsadat; Rabbani-Khorasgani, Mohammad; Hosseini, Sayyed Mohsen; Mokarian, Fariborz; Mahdavi, Hoda; Roayaei, Mahnaz

    2015-07-01

    Radiotherapy is frequently used in treatment approaches of pelvic malignancies. Nevertheless, it has some known systemic effects on blood cells and the immune system that possibly results in their susceptibility to infection. Probiotics are live microbial food ingredients that provide a health advantage to the consumer. Honey has prebiotic properties. The aim of this clinical trial was to investigate probable effects of probiotic or probiotics plus honey on blood cell counts and serum IgA levels in patients receiving pelvic radiotherapy. Sixty-seven adult patients with pelvic cancer were enrolled. Patients were randomized to receive either: (1) Probiotic capsules (including: Lactobacillus casei, Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus bulgaricus, Bifidobacterium breve, Bifidobacterium longum, and Streptococcus thermophiles) (n = 22), (2) probiotic capsules plus honey (n = 21) or (3) placebo capsules (n = 24) all for 6 weeks. Blood and serum samples were collected for one week before radiotherapy and 24-72 h after the end of radiotherapy. White blood cells (WBC), red blood cells (RBC), platelet counts, and serum IgA level were not significantly changed in patients taking probiotic (alone or plus honey) during pelvic radiotherapy. The mean decrease in RBC count was 0.52, 0.18, and 0.23 × 10(6) cells/μL, WBC count was 2.3, 1.21, and 1.34 × 10(3) cells/μL and platelet count was, 57.6, 53.3, and 66.35 × 10(3) cells/μL for the probiotic, probiotic plus honey, and placebo groups, respectively. The mean decrease of serum IgA was 22.53, 29.94, and 40.73 mg/dL for the probiotic, probiotic plus honey, and placebo groups, respectively. The observed nonsignificant effect of probiotics may be in favor of local effects of this product in the gut rather than systemic effects, however, as a trend toward a benefit was indicated, further studies are necessary in order to extract effects of probiotics or probiotic plus honey on hematologic and

  4. Nevada Kids Count Data Book, 1997.

    Science.gov (United States)

    We Can, Inc., Las Vegas, NV.

    This Kids Count data book is the first to examine statewide indicators of the well being of Nevada's children. The statistical portrait is based on 15 indicators of child well being: (1) percent low birth-weight babies; (2) infant mortality rate; (3) percent of children in poverty; (4) percent of children in single-parent families; (5) percent of…

  5. Isospectral graphs with identical nodal counts

    International Nuclear Information System (INIS)

    Oren, Idan; Band, Ram

    2012-01-01

    According to a recent conjecture, isospectral objects have different nodal count sequences (Gnutzmann et al 2005 J. Phys. A: Math. Gen. 38 8921–33). We study generalized Laplacians on discrete graphs, and use them to construct the first non-trivial counterexamples to this conjecture. In addition, these examples demonstrate a surprising connection between isospectral discrete and quantum graphs. (paper)

  6. Phase-space quark counting rule

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Gin, Chao; Lo, Shui-Yin [Academia Sinica, Beijing (China). Inst. of High Energy Physics

    1981-05-21

    A simple quark counting rule based on the phase-space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter-free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions.

  7. Statistical tests to compare motif count exceptionalities

    Directory of Open Access Journals (Sweden)

    Vandewalle Vincent

    2007-03-01

    Full Text Available Abstract Background Finding over- or under-represented motifs in biological sequences is now a common task in genomics. Thanks to p-value calculation for motif counts, exceptional motifs are identified and represent candidate functional motifs. The present work addresses the related question of comparing the exceptionality of one motif in two different sequences. Just comparing the motif count p-values in each sequence is indeed not sufficient to decide if this motif is significantly more exceptional in one sequence compared to the other one. A statistical test is required. Results We develop and analyze two statistical tests, an exact binomial one and an asymptotic likelihood ratio test, to decide whether the exceptionality of a given motif is equivalent or significantly different in two sequences of interest. For that purpose, motif occurrences are modeled by Poisson processes, with a special care for overlapping motifs. Both tests can take the sequence compositions into account. As an illustration, we compare the octamer exceptionalities in the Escherichia coli K-12 backbone versus variable strain-specific loops. Conclusion The exact binomial test is particularly adapted for small counts. For large counts, we advise to use the likelihood ratio test which is asymptotic but strongly correlated with the exact binomial test and very simple to use.

  8. Photon counting with small pore microchannel plates

    International Nuclear Information System (INIS)

    Martindale, A.; Lapington, J.S.; Fraser, G.W.

    2007-01-01

    We describe the operation of microchannel plates (MCPs) with 3.2μm diameter channels as photon counting detectors of soft X-rays. Gain and temporal resolution measurements are compared with theoretical scaling laws for channel diameter. A minimum pulse width of 264ps is observed for a two stage multiplier at a total bias voltage of ∼1930V

  9. Alabama Kids Count 2002 Data Book.

    Science.gov (United States)

    Curtis, Apreill; Bogie, Don

    This Kids Count data book examines statewide trends in well-being of Alabamas children. The statistical portrait is based on 18 indicators in the areas of child health, education, safety, and security: (1) infant mortality rate; (2) low weight births; (3) child health index; (4) births to unmarried teens; (5) first grade retention; (6) school…

  10. Alabama Kids Count 2001 Data Book.

    Science.gov (United States)

    Curtis, Apreill; Bogie, Don

    This Kids Count data book examines statewide trends in well-being for Alabama's children. The statistical portrait is based on 17 indicators in the areas of health, education, safety, and security. The indicators are: (1) infant mortality rate; (2) low weight births; (3) child health index; (4) births to unmarried teens; (5) first grade retention;…

  11. Spontaneous Non-verbal Counting in Toddlers

    Science.gov (United States)

    Sella, Francesco; Berteletti, Ilaria; Lucangeli, Daniela; Zorzi, Marco

    2016-01-01

    A wealth of studies have investigated numerical abilities in infants and in children aged 3 or above, but research on pre-counting toddlers is sparse. Here we devised a novel version of an imitation task that was previously used to assess spontaneous focusing on numerosity (i.e. the predisposition to grasp numerical properties of the environment)…

  12. Stalking the count. Dracula, Fandom and Tourism

    NARCIS (Netherlands)

    S.L. Reijnders (Stijn)

    2011-01-01

    textabstractLarge numbers of tourists travel to Transylvania every year, looking for traces of Count Dracula. This article investigates why people feel the need to connect fictional stories, such as Dracula, with identifiable physical locations, and why they subsequently want to visit these

  13. Liquid scintillation counting (LSC) - an overview

    International Nuclear Information System (INIS)

    Ravi, S.; Mathew, K.M.

    2005-01-01

    In Liquid Scintillation Counting, the amount of light produced is proportional to the amount of radiation present in the sample and the energy of the light produced is proportional to the energy of the radiation that is present in the sample. This makes LSC a very convenient tool to measure radioactivity

  14. Counting Women's Work in Vietnam | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2017-07-31

    Jul 31, 2017 ... These gender equality indicators are shedding light on girls' and women's ... Young people do a tremendous amount of unpaid care work at the ages when ... Read the report "Counting Women's Work in Vietnam" · View the ...

  15. Going Online to Make Learning Count

    Science.gov (United States)

    Brigham, Cathy; Klein-Collins, Rebecca

    2011-01-01

    Adult students often come to higher education with college-level learning that they have acquired outside of the classroom--from the workplace, military service, self-study, or hobbies. For decades, many forward-thinking colleges and universities have been offering services to evaluate that learning and award it college credit that counts towards…

  16. Health Advocacy--Counting the Costs

    Science.gov (United States)

    Dyall, Lorna; Marama, Maria

    2010-01-01

    Access to, and delivery of, safe and culturally appropriate health services is increasingly important in New Zealand. This paper will focus on counting the costs of health advocacy through the experience of a small non government charitable organisation, the Health Advocates Trust, (HAT) which aimed to provide advocacy services for a wide range of…

  17. The Fallacy of Word-Counts.

    Science.gov (United States)

    Engels, L.K.

    1968-01-01

    The greatest fallacy of word counts, the author maintains, lies in the fact that advocates of frequency lists stress the high percentage without telling the whole truth. It has become common to pretend that a frequency list of 3,000 words covers 95 percent of the language, that it enables a person to speak and understand a foreign language by…

  18. Differential white cell count by centrifugal microfluidics.

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  19. Counting Subspaces of a Finite Vector Space

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 15; Issue 11. Counting Subspaces of a Finite Vector Space – 1. Amritanshu Prasad. General Article Volume 15 Issue 11 November 2010 pp 977-987. Fulltext. Click here to view fulltext PDF. Permanent link:

  20. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control