  1. Non-destructive testing of rocket propellant quality using -X-ray radiography

    International Nuclear Information System (INIS)

    Arayaprecha, W.

    1979-01-01

    Currently, X-rays radiography has been used extensively in various industries. In this thesis, X-rays has been used in the study of compaction of rocket propellant. For a rocket, to gain an accurate guidance result, the propellant used must be mixed and compacted thoroughly. The quality control of the production of propellant sticks must be carefully done. In this study of non-destructive quality testing of rocket propellant, at first the ultrasonic rays was used to test its homogeneity. However, because the density of the propellant was too low, the test equipment could not detect any reflected signals from the propellant being tested. Then the new procedure using X-rays radiography was tried. The variables in the test procedure were voltage, amperage and the focal-film distance. Also different types of films were used. The results of this experiment were then used to construct an exposure chart for testing the homogeneity of the rocket propellant. The advantage of this chart is that a tester can use this table with propellant sticks of different sizes if they have similar density to the density specified in the chart. Also, it is not necessary that the mixture of the testing propellant be the same as the ones used to construct this chart

  2. Characteristics and quality test of X-ray with CZT detector

    International Nuclear Information System (INIS)

    Rianto, Sugeng

    2000-01-01

    The study examines the use of direct measurements of x-ray spectra for testing the quality of x-ray beam by using a peltier-cooled CZT detector under different conditions. The typical calibration of the spectrometry system shows that the energy resolution of the system is 1,2 keV at 122 keV of 57 Co. The utilization CZT based spectrometer for assessing the quality of x-ray machine on its spectra show that the CZT could accurately measure the spectra at various kVp, m As and filtration, except at the kVp greater than 140 and m As higher than 2 without added filtration. A comparison of CZT with the field instruments showed that there is a reasonable agreement between the Keithley and CZT at lower energies regardless of filtration however at high energies there is a large difference.In contrast the discrepancy between the CZT and Nero increased at lower photon energies particularly for high filtration

  3. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  4. A set of X-ray test objects for quality control in television fluoroscopy

    International Nuclear Information System (INIS)

    Hay, G.A.; Clarke, O.F.; Coleman, N.J.; Cowen, A.R.

    1985-01-01

    The history of performance testing in Leeds of television fluoroscopic systems is briefly outlined. Using the visual, physical and technological requirements as a basis, a set of nine test objects for quality control in television fluoroscopy is described. The factors measured by the test objects are listed in the introduction; the test objects and their function are fully described in the remainder of the paper. The test objects, in conjunction with a television oscilloscope, give both subjective and objective information about the X-ray system. Three of the test objects enable the physicist or engineer to adjust certain aspects of the performance of the X-ray system. The set of nine test objects is available commercially. (author)

  5. Testing of quality of welded joints using heavy-current pulse X-ray apparatuses

    International Nuclear Information System (INIS)

    Gusev, E.A.; Firstov, V.G.

    1988-01-01

    The possibilities of carrying out of radiographic and electroradiographic testing of quality of welded joints using heavy-current pulse X-ray apparatuses under the mode of single pulses are shown. Basic quantitative characteristics of radiographic testing permitting to detect the focus distance, sensitivity behaviour and optical density of image are presented. Peculiarities of electroradiographic image formation under the mode of single pulses of nanosecond range are analysed. The outlook of heavy-current pulse X-ray apparatus application under the mode of single pulses in industry is estimated

  6. X-ray beam qualities for dental radiology purposes

    International Nuclear Information System (INIS)

    Santos, Marcus Aurelio P. dos; Fragoso, Maria da Conceicao de F.; Lima, Ricardo de A.; Hazim, Clovis A.

    2009-01-01

    In order to establish characteristics or properties of equipment for diagnostic radiology, e.g. ion chambers and semiconductor detectors, calibration laboratories offer a set of well-defined radiation conditions, called X-ray qualities, which can be used for many Physics studies and medical purposes. The standardization of radiation qualities has been carried out in several fields of study, but little attention has been given to the area of dental radiology, mainly for medical and physical applications using single-phase units with half-wave rectification. For this reason, a single-phase dental unit with adjustable peak voltage and tube current, called 'variable potential X-ray equipment', was developed aiming to define X-ray beam qualities for test and calibrations purposes. X-ray spectra at 50, 60 and 70 kVp were determined by using a CdTe detector and compared with those obtained for ten commercial X-ray dental units. As a result of this study, a set of X-ray qualities for the variable potential X-ray equipment was determined. The X-ray qualities spectra were utilized as reference for determination of a new set of X-ray qualities characterized for a constant potential X-ray equipment. Thus, sets of X-ray qualities were standardized and implemented in two X-ray laboratories: one with the variable potential X-ray equipment and other with constant potential X-ray equipment. These reference X-ray beam qualities should be used for test and calibration purposes involving scientific studies and services. (author)

  7. On the methods of determination of x-ray sources protection quality in x-ray diagnostic equipment

    International Nuclear Information System (INIS)

    Vladimirov, L.V.

    1973-01-01

    Existing procedures for assessing the quality of shielding of X-ray radiators are compared; these procedures are shown to have a number of shortcomings and to be very time-consuming. A procedure is offered in which shielding quality is tested in two stages: (1) X-ray tests aimed at determining the quality of protection of the X-ray tube unit; and (2) dosimeter tests proper. The results of measurements are compared with maximum permissible dosage rate

  8. Polar gamma ray mode for testing weld quality natural gas pipeline

    International Nuclear Information System (INIS)

    Shahout, A. M.; Mahmood, A.Sh.

    2005-01-01

    The polar gamma-ray radiography method was studied extensively, gamma ray from Ir 192 source was used to detect weld defects in the main gas pipeline extending from Kh oms to Tripoli, gamma ray radiographic inspections were carried out according to the Astm(1) standards, and the radiographs were analyzed according to quality specifications API(2) standard-1104. The polar gamma ray mode has been applied to specimens of weld joints of pipes used in this pipeline in the reg [the kilometer 118(3)] and [the kilometer 123], and weld joints in the SLR 7 stz in the region [the kilometer 125]. The results obtained from gamma-rays have discussed and analyzed

  9. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  10. Quality assurance and image improvement in diagnostic radiology with X-rays

    International Nuclear Information System (INIS)

    Evans, S.H.

    1988-01-01

    Basic quality assurance tests for x-ray sets are considered (tube potential, timing, output, H-V layer, focal-spot size, alignment and perpendicularity of the light-beam diaphragm) together with more specific quality-assurance tests such as tomographic tests, image intensifier and mammographic tests. (UK)

  11. Quality assurance for diagnostic X-ray machines in Tanzania

    International Nuclear Information System (INIS)

    Sungita, Y.Y.; Mdoe, S.L.; Ngatunga, J.; Kitosi, A.E.; Muhogora, W.E.

    1998-01-01

    In this presentation it is being discussed a close relationship between the prevention of accidents involving apparatus that generates the ionizing radiation (x-ray tubes etc.) and the need to perform quality control procedures and make follow-up corrective maintenance procedures. A summary of results of quality control performance of x-ray machines in certain centers in Tanzania is tabled and measures to overcome some of the observed problems are recommended. The number of X-ray units inspected were 219, out of which 123 were working, 75 were out of order, 6 units were not yet installed and those which are working with faulty parts were 15. The performance of quality assurance for X-Ray units (57) tested showed that 36.8% didn't qualify. About 80% of these equipment are more than 15 years old. (author)

  12. Quality control of diagnostic x-ray equipment and film processing

    International Nuclear Information System (INIS)

    1993-01-01

    According to the section 40 of the Radiation Act (592/92), the licensee is required in Finland to make the arrangements to control the function of the radiation equipment and related facilities used for medical procedures. The guide explains how quality control can be organized for diagnostic x-ray equipment. It also gives recommendations for constancy tests for conventional x-ray radiographic and fluoroscopic equipment and for film processing. The recommendations are based on the publications and statements of the International Committee for Radiation Protection (ICRP) and standardization organizations. The intention is that the operators of x-ray equipment or the maintenance personnel are able to perform the quality control tests presented in the guide

  13. Quality control of diagnostic x-ray units

    International Nuclear Information System (INIS)

    Marinkovic, O.; Milacic, S.; Jovicic, D.; Tanaskovic, I.

    2001-01-01

    The quality control program for diagnostic x-ray units has started at the Institute of Occupational and Radiological Health during 1990. It includes, among other measurements, reproducibility of dose, high voltage and exposure time. Dose reproducibility was less than 5% for 70% of tested x-ray units. The exposure time and high voltage reproducibility were less than 5% in 60% cases. The cassettes with amplifying foils made from components of rare earth are used in 10% of all x-ray departments. It is very important to work as much as it is possible to modernize general infrastructure as the radiological protection of patients would be better. (author)

  14. Quality assurance through constancy control for X-ray film processors

    International Nuclear Information System (INIS)

    Weberling, R.

    1982-01-01

    A control method to check the reproduction of X-ray film processors and necessary instruments is presented. The application of a light sensitometer allows the production of test films daily, independent of X-ray exposures, X-ray film cassettes and X-ray intensifying screens. The optical densities on the test films will be read by means of a densitometer and the results are plotted on a special control chart. A limitation through optical densities of +-0,15 for Speed Index and +-0,20 for Contrast Index determines the tolerance variation for X-ray film processors. Targets of this control method are uniform image quality, dose reduction and saving of cost. (orig.) [de

  15. Quality assurance in X-ray diagnostic radiology - Report II

    International Nuclear Information System (INIS)

    Fosmark, H.; Rozycki, Z.

    1987-01-01

    In the context of an analysis of technical quality assurance in Norwegian X-ray departments, a survey has been carried out in 21 laboratories in 4 hospitals. The tests were restricted to equipment used in general radiography, and the parameters analysed were of kV (using an electronic penetrameter), exposure time, waveform, output and automatic exposure control systems. In addition, a trial to compare overall performance in radiography and fluoroscopy was performed with a PMMP test phantom (SPRI). The survey is presented in two reports. The first one covers details of procedures and equipment. In this second report results are given and discussed. The results show that most of the equipment does function satifactorily, but also demonstrate the need to introduce quality assurance in X-ray departments

  16. Computer board for radioactive ray test

    International Nuclear Information System (INIS)

    Zuo Mingfu

    1996-05-01

    The present status of the radioactive-ray test system for industrial applications, the newly designed computer board for overcoming the shortcomings of the current system are described. The functions, measurement principles and the feature of the board as well as the test results for this board are discussed. The board puts together many functions of the radioactive-ray test system, such as energy calibration, MCS, etc.. It also provides many other subordinate practical function such as motor control, ADC and so on. The board summarizes two sets of test parts into one and therefore composes a powerful unit for the system. Not only can it replace all units in a normal test system for signal analysis, signal process, data management, and motor control, but also can be used in more complex test systems, such as those for double source/double energy/double channel testing, multichannel testing, position testing and core positioning, etc.. The board makes the test system more easier to achieve miniaturization, computerization goals, and therefore improves the quality of the test and reduces the cost of the system. (10 refs., 8 figs.)

  17. Bone quality analysis using X-ray microtomography and microfluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Sales, E.; Lima, I. [Nuclear Instrumentation Laboratory, PEN/COPPE/UFRJ, PO Box: 68509, 21.941-972, Rio de Janeiro (Brazil); Assis, J.T. de [Polytechnic Institute, DEMEC/UERJ (Brazil); Gomez, W. [Department of Electrical Engineering, Center of the National Polytechnic Institute (Mexico); Pereira, W.C.A. [Biomedical Engineering Program, COPPE/UFRJ, Rio de Janeiro (Brazil); Lopes, R.T., E-mail: ricardo@lin.ufrj.br [Nuclear Instrumentation Laboratory, PEN/COPPE/UFRJ, PO Box: 68509, 21.941-972, Rio de Janeiro (Brazil)

    2012-07-15

    Bone quality is an evaluation index often applied in order to interpret clinical observations made upon bone health, such as bone mineral density, micro and macro architecture, and mineral content. Conventional inspection techniques do not provide full information on trabecular bone quality. This study shows the high resolution potential and the non-destructive character of X-ray microtomography and microfluorescence upon the application of such techniques for evaluating bone quality. The mineral content assessment was performed by two-dimensional concentration mappings of calcium, zinc, and strontium. The results showed significant changes in bone morphology. - Highlights: Black-Right-Pointing-Pointer This study shows bone microarchitectural evaluation by X-ray microtomography and microfluorescence. Black-Right-Pointing-Pointer For this purpose, lumbar vertebrae of Wistar rats have been used as test subjects. Black-Right-Pointing-Pointer X-ray techniques proved to have an excellent perfomance in quantifying bone mineral content.

  18. Computer-supported quality control in X-ray diagnosis

    International Nuclear Information System (INIS)

    Maier, W.; Klotz, E.

    1989-01-01

    Quality control of X-ray facilities in radiological departments of large hospitals is possible only if the instrumentation used for measurements is interfaced to a computer. The central computer helps to organize the measurements as well as analyse and record the results. It can also be connected to a densitometer and camera for evaluating radiographs of test devices. Other quality control tests are supported by a mobile station with equipment for non-invasive dosimetry measurements. Experience with a computer-supported system in quality control of film and film processing is described and the evaluation methods of ANSI and the German industrial standard DIN are compared. The disadvantage of these methods is the exclusion of film quality parameters, which can make processing control almost worthless. (author)

  19. Characteristics of X ray calibration fields for performance test of radiation measuring instruments

    International Nuclear Information System (INIS)

    Shimizu, Shigeru; Takahashi, Fumiaki; Sawahata, Tadahiro; Tohnami, Kohichi; Kikuchi, Hiroshi; Murayama, Takashi

    1999-02-01

    Performance test and calibration of the radiation measuring instruments for low energy photons are made using the X ray calibration fields which are monochromatically characterized by filtration of continuous X ray spectrum. The X ray calibration field needs to be characterized by some quality conditions such as quality index and homogeneity coefficient. The present report describes quality conditions, spectrum and some characteristics of X ray irradiation fields in the Facility of Radiation Standard of the Japan Atomic Energy Research Institute (FRS-JAERI). Fifty nine X ray qualities with the quality index of 0.6, 0.7, 0.8 and 0.9 were set for the tube voltages between 10 kV and 350 kV. Estimation of X ray spectrum measured with a Ge detector was made in terms of exposure, ambient dose equivalent and fluence for all the obtained qualities. Practical irradiation field was determined as the dose distribution uniformity is within ±3%. The obtained results improve the quality of X ray calibration fields and calibration accuracy. (author)

  20. Technical quality assurance in conventional radiography by X-ray assistants

    International Nuclear Information System (INIS)

    Juran, R.; Buehler, G.; Schmidt, D.

    1989-01-01

    Without the X-ray assistant, regularly involved in everyday practice, technical quality assurance can hardly be accomplished. Therefore a model for the organization of quality assurance was developed and tested in practice. It implies accountable technical checks by the technician, that are controlled by a quality supervisor, and are subsequently evaluated by the radiation physics department. This positively influences quality consciousness of the radiographers and therefore the quality itself. (author)

  1. Using a tandem ionization chamber for quality control of X-ray beams

    International Nuclear Information System (INIS)

    Yoshizumi, Maira T.; Caldas, Linda V.E.

    2011-01-01

    X-ray beam qualities are defined by both the mean energies and by the half-value layers (HVL). Many international protocols use the half-value layer and the beam voltage to characterize the X-ray beam quality. A quality control program for X-ray equipment includes the constancy check of beam qualities, i.e., the periodical verification of the half-value layer, which can be a time consumable procedure. A tandem ionization chamber, developed at Instituto de Pesquisas Energeticas e Nucleares, was used to determine the HVL and its constancy for five radiotherapy standard beam qualities. This ionization chamber is composed by two sensitive volumes with inner electrodes made of different materials: aluminum and graphite. The beam quality constancy check test was performed during two months and the maximum variation obtained was 1.24% for the radiation beam quality T-10. This result is very satisfactory according to national recommendations. (author)

  2. The main tests for quality control in X-ray equipment of radiodiagnosis

    International Nuclear Information System (INIS)

    Ferreira, R.S.

    1988-01-01

    All aspects of the relation between patient, examination and diagnosis for controling the quality in radiodiagnosis are showed. The bundle collimation for decreasing the scattered radiation in patient and the systems for measuring the exposure time are described. The yield valuation and the tension for X-rays tube are also cited. (C.G.C.) [pt

  3. The introduction of compulsory compliance testing of medical diagnostic x-ray equipment in Western Australia

    International Nuclear Information System (INIS)

    Rafferty, M. W.; Jacob, C. S.

    1995-01-01

    Performance testing of medical diagnostic X-ray equipment can reveal equipment faults which, while not always clinically detectable, may contribute to reduced image quality and unnecessary radiation exposure of both patients and staff. Routine testing of such equipment is highly desirable to identify such faults and allows them to be rectified. The Radiological council of Western Australia is moving towards requiring compulsory compliance testing of all (new and existing) medical diagnostic X-ray equipment that all new mobile radiographic and new mammographic X-ray equipment be issued with a compliance test certificate as a prerequisite for registration. Workbooks which provide details of the tests required and recommended test methods have been prepared for medical radiographic (mobile and fixed), fluoroscopic and mammographic X-ray equipment. It is intended that future workbooks include details of the tests and methods for dental and computed tomography X-ray units. The workbooks are not limited to the compliance testing of items as specified in the Regulations, but include tests for other items such as film processing, darkrooms and image quality (for fluoroscopic equipment). Many of the workbook tests could be used within a regular quality assurance program for diagnostic X-ray equipment. Persons who conduct such compliance tests will need to be licensed and have all test certificates endorsed by a qualified expert. Suitable training and assessment of compliance testers will be required. Notification of such tests (including non-compliant items and corrective actions taken) will be required by the Radiological Council as a condition of equipment registration. 9 refs

  4. Automated Quality Assurance of Medical Digital X-Ray Equipment

    International Nuclear Information System (INIS)

    Zelikman, Mikhail; Kruchinin, Sergey

    2013-06-01

    Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector's output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object's digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital x-ray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector's noise variance and detector's gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector's surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine

  5. ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, R A; Anderson, S G; Barty, C P; Chu, T S; Ebbers, C A; Gibson, D J; Hartemann, F V; Adolphsen, C; Jongewaard, E N; Raubenheimer, T; Tantawi, S G; Vlieks, A E; Wang, J W

    2010-05-12

    In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

  6. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  7. Testing FlexRay ECUs with a hardware-in-the-loop simulator; Test von FlexRay-Steuergeraeten am Hardware-in-the-Loop Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Stroop, J.; Koehl, S. [dSPACE GmbH, Paderborn (Germany); Peller, M.; Riedesser, P. [BMW AG, Muenchen (Germany)

    2005-07-01

    To master the data communication of complex and safety relevant systems within future vehicles, the BMW Group prepares the application of FlexRay. The accompanying development process plays an important role for the quality, stability and reliability of those systems. Hardware-in-the-loop simulation and test stands are indispensable constituents and they are an integral part of the validation process. The following contribution describes the technology that is used within the BMW Group in more detail, especially in terms of communication networks with FlexRay. (orig.)

  8. Analyze for the Quality Control of General X-ray Systems in Capital region

    International Nuclear Information System (INIS)

    Kang, Byung Sam; Lee, Kang Min; Shin, Woo Yong; Park, Soon Chul; Choi, Hak Dong; Cho, Yong Kwon

    2012-01-01

    Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

  9. Image quality assessment and medical physics evaluation of different portable dental X-ray units.

    Science.gov (United States)

    Pittayapat, Pisha; Oliveira-Santos, Christiano; Thevissen, Patrick; Michielsen, Koen; Bergans, Niki; Willems, Guy; Debruyckere, Deborah; Jacobs, Reinhilde

    2010-09-10

    Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay 60 kVp, Nomad 60 kVp and Rextar 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Statistical analysis showed good quality imaging for all system, with the combination of Nomad and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p1m: Rextar <0.2 microGy, MinRay <0.1 microGy). The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  11. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1996-09-01

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  12. Programs and procedures for assessing quality of spectral gamma-ray borehole data for the UGTA

    International Nuclear Information System (INIS)

    Conaway, J.G.

    1998-01-01

    This report describes the procedures and computer programs used to process spectral gamma-ray borehole logging data in the UGTA (UnderGround Test Area) program at the NTS (Nevada Test Site) to assess data quality. These programs and procedures were used to analyze data from five boreholes in the UGTA program. Development of these computer programs and procedures required considerable effort and the primary purpose of this report is to provide continuity with future activities related to spectral gamma-ray borehole logging in the UGTA program. This is especially important because of the long time interval between cessation of logging in April, 1996 and the next round of activity, which has not yet occurred. This report should also be useful if any quality control issues arise regarding past or forthcoming spectral gamma-ray log analyses. In the characterization work underway at the Nevada Test Site Underground Test Area, the logging contractor, Western Atlas, agreed to identify five artificial nuclides based on their gamma-ray signatures. Those nuclides are 60 Co, 106 Ru, 125 Sb, 134 Cs, and 137 Cs. In the case of 106 Ru, which is not a gamma emitter, any detected gamma rays come from the daughter nuclide 106 Rh which has a half-life of 30 s. With such a short half-life, 106 Rh can be considered to be in equilibrium with 106 Ru under most conditions so the result is the same as if the gamma rays were emitted by the 106 Ru. The Western Atlas spectral gamma-ray curve plots from a given borehole present detailed qualitative information on the apparent distribution of natural and artificial nuclides with depth in the borehole. The computer programs and procedures described in this report were used to provide a quality analysis of the contractor's processed data and to work with the contractor to validate and/or refine their existing automatic processing. This was done using a procedure that was developed and tested successfully in earlier work at the NTS; the revised

  13. X-ray calibration qualities

    International Nuclear Information System (INIS)

    Burns, J.E.

    1998-01-01

    Since the recent publication of IAEA Technical Reports Series No. 374 ''Calibration of Dosimeters Used in Radiotheraphy'', there have been a number of queries about the origin of, and the rationale behind, the X-ray qualities recommended for calibration purposes. The simple answer is that these are the qualities derived at the UK National Physical Laboratory (NPL) in 1971 for calibration of therapy-level dosimeters and which are still in use for that purpose. As some SSDLs may have difficulties in adopting these exact combinations of kV and filtration. This paper discusses the basic ideas involved, and how to go about deriving a different series of qualities

  14. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    Inservice testing of safety-related components at nuclear power plants is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section 11 of the Code state test method and frequency requirements for pumps and valves, respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  15. Quality assurance test of a real time radiography system

    International Nuclear Information System (INIS)

    Yadav, R.K.; Rama, R.; Sharma, A.; Kannan, R.

    2005-01-01

    Any radiation generating equipment can be used and marketed in India only after obtaining specific type approval certificate from the Competent Authority i.e. Chairman, Atomic Energy Regulatory Board (AERB), Mumbai. Recently AERB has enforced a directive that the Industrial X-ray machines should also be permitted to use only after getting NOC or type approval. Type approval is granted based upon the satisfactory QA test report of the radiation generating equipment. X-ray machines with Real Time Radiography (RTR) facility are used in industrial radiography for faster inspection of equipment's and products online. A standard test protocol was developed for QA tests of a real time radiography system. This will be helpful for evaluation of an industrial X-ray machine. Also above procedure can be used to check a RTR system each day or a system-qualification can be done when the image quality diminishes as recommended by American Society of Testing Material (ASTM). Various tests carried out on a constant potential 450 kV, 10 mA industrial X-ray machine having real time radiography facility to monitor the products online, is described in this paper. (author)

  16. Quality criteria for chest X-ray image

    International Nuclear Information System (INIS)

    Krieg, R.

    1985-01-01

    A distinction has to be made between invariable and variable criteria in the determination of chest X-ray picture quality criteria. The invariable criteria are defined by the properties of the object and the psychophysiological laws of perception and cognition, and the variable criteria are determined by the prevailing state of the art of technology. An agreement on these criteria is based on the knowledge of the nature and the technical conditions of X-ray picture production and reproduction. The slogan 'the best picture at the lowest dose' dominates, too, the discussion centering around the X-ray picture of the chest, its quality and criteria. (orig./MG) [de

  17. Which points deserve special attention in the new guidelines on X-ray use (testing guidelines for experts and quality assurance guidelines)?

    International Nuclear Information System (INIS)

    Ewen, K.; Lauber, I.

    2004-01-01

    Two important guidelines for the application of X-rays in medicine became effective on 1 October 2003 and 1 December 2003. These are testing guidelines for experts and quality assurance guidelines. Both guidelines are very extensive and not always easy to interpret. In the present paper the authors try to explain in detail some chapters important for radiology and to make the necessary technical background transparent. Both authors took an essential part in forming the guidelines. (orig.) [de

  18. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    This document discusses inservice testing of safety-related components at nuclear power plants which is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section XI of the Code state test method and frequency requirements for pumps and valves respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  19. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  20. Tuning of the cosmic-ray test system of the BESIII drift chamber

    International Nuclear Information System (INIS)

    Wu Zhi; Liu Jianbei; Qin Zhonghua; Wu Linghui; Chen Chang; Chen Yuanbo; Chen Mali; Chen Xihui; Dong Mingyi; Guan Beiju; Huang Jie; Jiang Xiaoshan; Jin Yan; Li Fei; Li Renying; Li Xiaonan; Lei Guangkun; Liu Rongguang; Luo Xiaolan; Ma Xiaoyan; Sheng Huayi; Sun Hansheng; Tang Xiao; Wang Lan; Wang Liang; Xu Meihang; Zhang Jian; Zhang Hongyu; Zhang Yinhong; Zhao Yubin; Zhao Pingping; Zhu Kejun; Zhu Qiming; Zhuang Bao'an

    2010-01-01

    The BESIII drift chamber and its subsystems need a cosmic-ray test after the chamber construction to check the chamber construction quality, testing the joint operation of the whole system and the performance of the chamber. The noise performance, drift time and charge measurements, and the scanning of channels were examined specifically. The preliminary results of the test indicate that the whole system works well. (authors)

  1. Test facility for astronomical x-ray optics

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Lewis, Robert A.; Bordas, J.

    1990-01-01

    Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earth's atmosphere. These devices require a large collection aperture and the imaging of an x-ray source that is essentially placed at infinity. The ideal testing system for these optical elements has to appro......Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earth's atmosphere. These devices require a large collection aperture and the imaging of an x-ray source that is essentially placed at infinity. The ideal testing system for these optical elements has...... to approximate that encountered under working conditions; however, the testing of these optical elements is notoriously difficult with conventional x-ray generators. Synchrotron radiation (SR) sources are sufficiently brilliant to produce a nearly perfect parallel beam over a large area while still retaining...... a flux considerably higher than that available from conventional x-ray generators. A facility designed for the testing of x-ray optics, particularly in connection with x-ray telescopes, is described. It is proposed that this facility will be accommodated at the Synchrotron Radiation Source...

  2. [Quality assurance from the viewpoint of the x-ray film industry].

    Science.gov (United States)

    von Volkmann, T

    1992-08-01

    The parameters of a film-screen-combination are listed in the directive to section 16 of the german X-ray Regulation. These parameters are determined by methods described in DIN standards and published by the manufacturer. Comparable but less precise parameters are determined in the Acceptance Test. For physical reasons it is not possible to determine the speed of an X-ray film or the intensification factor of a screen separately. The films, screens and processing chemicals delivered by the members of the manufacturer association ZVEI are kept below a deviation (expressed as relative contribution to the system speed S) of +/- 10% for the majority of products, the upper limit is +/- 15%. Poor storage and transport conditions may adversely affect the quality of X-ray films. A special labeling of the film box shall serve to guarantee safe distribution channels. The processing conditions are adjusted at the Acceptance Test according to the manufacturers recommendations. The Constancy Test of film processing serves to maintain these correct conditions. Methods deviating from the DIN-method are of limited (Bayerische method) or no value (Stuttgart method).

  3. Constancy check of beam quality in conventional diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Alessandro M.; Badin, Romulo S.; Leite, Marina S.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment

  4. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  5. From quality control to quality systems in x-ray radiology. Step by step approach

    International Nuclear Information System (INIS)

    Gendrutis Morkunas; Julius Ziliukas

    2007-01-01

    Complete test of publication follows. Quality systems in x-ray radiology as in any area of medical exposure is an important tool of optimization of radiation protection. Creation of these systems is related with a number of problems: limited resources, lack of knowledge and experience, negative attitude of hospitals staff and administration, lack of advice from outside. Problems related with transitionary period might be softened by the step by step approach. The following steps might be indicated: providing information on quality systems to hospital staff and administration, simple quality control procedures done by outside experts in hospitals, preparation of quality related procedures by hospital staff, practical implementation of quality control procedures done by hospital staff, preparation of quality manual by hospital staff, its integration into common quality system of hospital (if it is available) and constant development, measurements of performance indicators (e.g., patients' doses) and introduction of corrective measures if necessary, dissemination of experience by expert organizations and more advanced hospitals. These steps are to be discussed in the presentations based on Lithuanian experience since 1998.

  6. VETA-I x ray test analysis

    Science.gov (United States)

    Brissenden, R. J. V.; Chartas, G.; Freeman, M. D.; Hughes, J. P.; Kellogg, E. M.; Podgorski, W. A.; Schwartz, D. A.; Zhao, P.

    1992-01-01

    This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report.

  7. The Northern regional programme for the acceptance testing of X-ray equipment

    International Nuclear Information System (INIS)

    Faulkner, K.; Harrison, R.M.; Kotre, C.J.; Smith, S.; Davies, M.; Barker, P.

    1989-01-01

    Since 1984 the UK Northern Regional Medical Physics Department has participated in a regional acceptance testing programme for all X-ray equipment from mobile units to computed tomography scanners. Organizational and radiation physics aspects of the programme are described. Three levels of tests are performed by physicists: the first on installation, the second after 3 months, the final visit just prior to the end of the manufacturers warranty. The second test is only performed if any aspect of performance requires rechecking as a result of the first. Acceptance test protocols are based on those published by the Institute of Physical Sciences in Medicine. Details limiting values for the acceptance test measurements are given. In some instances testing has resulted in modifications to the design and construction of X-ray equipment. Acceptance testing is important in determining a baseline standard of performance against which routine quality assurance may be assessed. (author)

  8. The Northern Regional Programme for the acceptance testing of X-ray equipment

    International Nuclear Information System (INIS)

    Faulkner, K.; Harrison, R.M.; Kotre, C.J.; Smith, S.; Davies, M.; Barker, P.

    1989-01-01

    Since 1984 the Regional Medical Physics Department has participated in a regional acceptance testing programme for all X-ray equipment from mobile units to computed tomography scanners. The organizational and radiation physics aspects of the programme are described. Three levels of tests are performed by physicists: the first on installation, the second after 3 months, and the final visit just prior to the end of the manufacturer's warranty. The second test is only performed if any aspect of performance requires rechecking as a result of the first visit. Acceptance test protocols are based on those published by the Institute of Physical Sciences in Medicine. Details of the limiting values for the acceptance test measurements are given. The results of the programme are discussed. In some instances the testing has resulted in modifications to the design and construction of X-ray equipment. Acceptance testing is important in determining a baseline standard of performance against which routine quality assurance may be assessed. (author)

  9. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  10. The performance test of anti-scattering x-ray grid with inclined shielding material by MCNP code simulation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jun Woo; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2016-06-15

    The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination.

  11. X-ray quality increasing system controlled by single-chip microcomputer in single phase fluoroscopy unit

    International Nuclear Information System (INIS)

    Wang Qiaolin; Gu Hongmei

    2004-01-01

    Objective: To decrease the amount of radiation that doctor and patient receives by increasing X-ray quality. Methods: Using Single-chip Microcomputer technology, test and modulate AC(Alternating Current) from high voltage generator by IGBT. X-ray tube generates X-rays only at high energy area. Thus the amount of radiation decreases. Results: The tube current decreases remarkably and the amount of radiation that doctor and patient receives decreases effectively. Conclusion: the system can effectively decrease the amount of radiation and is widely applicable to the upgrade of all kinds of single phase X-ray units. (authors)

  12. Results of evaluation of quality control measurement instrument of x-ray diagnostic equipment by non-invasive method

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Elbern, Alvin W.

    1996-01-01

    This work shows the results of the tests realized on Santa Rita Hospital (Porto Alegre), using a non invasive quality control measurement instrument, developed in this University for fast measurement of essential parameters of X-rays diagnostic equipment. In the tests we used a diagnostics Siemens X ray, model Heliofos 4E as our standard equipment. The linearity test of sensor probe and the exposure rate calibration was performed, with a Palmer Dosimeter. For the kVp and exposure time we used a RTI commercial instrument. (author)

  13. X-ray testing of fiber composite plastics

    International Nuclear Information System (INIS)

    Altmann, O.; Lembke, B.

    1984-01-01

    Besides the ultrasonic test, X-raying is the most important non-destructive test procedure for supporting fibre composite structures. This report presents some auxiliary means and test results regarding the limits of fault detectibility during the X-raying of fiber composite structures, preferrably carbon fiber laminates (CFRP). (orig.) [de

  14. A quality measurement study of a diagnostic x-ray

    International Nuclear Information System (INIS)

    Nishitani, Motohiro; Fujimoto, Nobuhisa; Yamada, Katsuhiko

    1982-01-01

    It is important to check periodically the quality and quantity of the X-rays emitted, in order to obtain the best possible performance from your diagnostic X-ray apparatus. The best way of checking the exact quality of the X-ray is to measure the spectrum of the X-ray, but it is not an easy task to carry out. The second way is to plot the attenuation curve of the X-rays. We have developed a method to plot the attenuation curve by a single exposure, utilizing J.r. Greening's empirical formula. The output of the three cavity ionization chambers, one with 7 mmAl filter, another with a 3 mmAl and the third without any filter, exposed to the same X-ray, were put into a microcomputer. The programming was arranged to display the attenuation curve of the X-rays, effective energy of the X-rays, the 1st HVL and the 2nd HVL on the CRT. The attenuation curves of the X-rays, emitted at a tube voltage at between 60 and 140 kV obtained by this method, agreed with the experimental results with an error of +-4 %. The effective energy obtained by this method agreed with the experimental data with an error of +-1 %. (author)

  15. A Test Facility For Astronomical X-Ray Optics

    DEFF Research Database (Denmark)

    Lewis, R. A.; Bordas, J.; Christensen, Finn Erland

    1989-01-01

    Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earths atmosphere. These devices require a large collection aperture and the imaging of an x-ray source which is essentially placed at infinity. The ideal testing system for these optical elements has...... to approximate that encountered under working conditions, however the testing of these optical elements is notoriously difficult with conventional x-ray generators. Synchrotron Radiation (SR) sources are sufficiently brilliant to produce a nearly perfect parallel beam over a large area whilst still retaining...... a flux considerably higher than that available from conventional x-ray generators. A facility designed for the testing of x-ray optics, particularly in connection with x-ray telescopes is described below. It is proposed that this facility will be accommodated at the Synchrotron Radiation Source...

  16. Metrological analysis of constancy tests in conventional medical X-ray equipment

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Oliveira, Paulo Marcio C.; Squair, Peterson L.; Soares, Carlos M.; Silva, Teogenes A. da

    2005-01-01

    Constancy tests in x-ray diagnostic machines should follow performance requirements with the aim to verify their safety and quality and to protect workers, patients and public members that are or may be exposed to ionizing radiation risks. In the Brazilian state of Minas Gerais, from 1999 to 2004, 110 radiometric and evaluation reports of x-ray machines were issued by accredited professionals. Most of the reports did not provide the estimation of the measurement uncertainty that should be part of the results; it means that there is a lack of metrological care in such reports which may cause difficulties to get a conclusive analysis. In this work, relevant sources of uncertainties were identified and estimated for the following tests carried out in a conventional x-ray machine: high voltage accuracy and reproducibility, air kerma rate repeatability and linearity and half-value layer determination. This work gives details on the methodology and the expanded and combined uncertainty values for each measuring procedure, which may be adopted as representative values for analysis of radiometric report. (author)

  17. Image guided radiotherapy. Quality control of X ray equipment. S.F.P.M. report nr 29

    International Nuclear Information System (INIS)

    Delpon, Gregory; Aubignac, Leone; Bramoulle, Celine; Boutry, Christine; Guerin, Lucie; Lafay, Frederic; Benoit, David; Garcia, Robin; Jaegle, Enric; Vieillevigne, Laure; Dedieu, Veronique; Ferrrer, Ludovic; Guillhem, Marie-Therese; Lacaze, Brigitte; Mazurier, Jocelyne; Simon, Luc

    2014-01-01

    This report presents different X ray imagery systems used for positioning support in external radiation therapy, and installed in treatment rooms. If portal imagery systems and rail-mounted tomodensitometry systems are not addressed in this document, the authors distinguish and describe various embedded systems in which devices are directly mounted on the treatment apparatus (X-Ray Volume Imaging by Elekta, On Board Imager by Varian), peripheral systems which are independent from the machine (Cyberknife by Accuray and Exatrac by BrainLab), MVCT or Mega Voltage Computed Tomography systems (Tomotherapy by Accuray), and MVCBCT or Megavoltage Cone Beam Computed Tomography systems (Artiste by Siemens). After a brief presentation of these systems, the author present various aspects of quality controls (list, periodicity, test tolerance, tested objects), and then more precisely describe the above-mentioned systems. For each of them, the following aspects are addressed: generator, geometry, image quality, dose, environment and safety, gating module, quality controls

  18. Evaluation of quality control in the college of medical radiological sciences, conventional x-ray department

    International Nuclear Information System (INIS)

    Babiker, Esameldeen Mohamed Tom

    2002-02-01

    Quality control in diagnostic radiography aims to ensure continuous production of diagnostic images with optimum quality, using minimum necessary dose to the patients and staff. Therefore an ineffective quality control program can lead to poor quality images that can impair diagnosis, increase operating costs and contribute to unnecessary radiation exposure to both patients and staff. Apply basic quality control program is responsibility of each x-ray facility, and to achieve maximum benefits, all levels of management and technical staff must support and participate in operating the programme. The main parameters to be monitored during the quality control programme include: dose consistency, k Vp accuracy, k Vp variations, exposure timer accuracy, besides checking image receptors, recording system and processing conditions. The aims of this project is to evaluate the quality control in the x-ray department of the college of medical radiologic sciences. The evaluation was an experimental study done by checking the operational status of the radiographic equipment, beside data collection using questionnaires regarding quality control. In the applied experiments the results show that there is a noted variation in the accuracy of k Vp, exposure timer and also in the dose consistency. The obtained results from image receptors and processing system showed noted variations too. The results of the questionnaire and direct interviewing showed other causes of quality degradation such as absence of test tools, the status of the equipment, absence of regular quality control testing, in addition to absence of an organized team to deal with quality. (Author)

  19. Quality control of pediatric chest X-rays in diagnostic centers with and without pediatric competence

    International Nuclear Information System (INIS)

    Alt, C.D.; Engelmann, D.; Schenk, J.P.; Troeger, J.

    2006-01-01

    Purpose: Radiation protection in pediatric radiology is very important because of the particular sensitivity of radiosensitive organs in younger patients. Optimized image quality supports radiation protection and should be targeted. In our study we examined the quality of pediatric chest X-rays at diagnostic centers (university hospitals and other large clinics). We then evaluated differences in image quality in departments without pediatric competence (R) and departments with pediatric competence (PR). Materials and Methods: Our study was based on 313 conventional chest X-rays from 207 patients (192 p.a./a.p. and 121 lateral, 43 from R, 258 from PR and 12 neither from R nor KR) and 38 digital chest X-rays from 26 patients (25 p.a./a.p. and 13 lateral, 1 from R and 37 from PR). All patients (age 0 - 18 years) are from Nephroblastoma-Study SIOP-93/01-GPOH. We examined all initial chest X-rays, which were sent to us for evaluation upon request between 4/3/2002 and 6/14/2002. The examined parameters were: exposure, centering of the X-rays/patient positioning, collimation and sharpness. The X-rays were evaluated on a scale from 1 (best result) to 5 (worst result), resulting in an overall score of A = optimum, B = minor problems, C = major problems, or D = unusable. The optical density, the center of the image and the relative field size were also measured. Statistical tests (Mann-Whitney-U and log regression) were carried out on the conventional images. The study was performed retrospectively. The exposure, sharpness and optical density of the digital X-rays were not analyzed. Results: In the case of all conventional X-rays, the quality of the centering of the X-rays/patient positioning and collimation was moderate (average scale value: 2.4 and 2.8), and the quality of the exposure and sharpness was good and very good (average scale value: 1.9 and 1.5). The quality of the chest X-rays in departments with additional pediatric radiological expertise was better mainly in

  20. Quality assurance and independent dosimetry for an intraoperative x-ray device

    International Nuclear Information System (INIS)

    Eaton, D. J.

    2012-01-01

    Purpose: Quality assurance is an essential component of accurate and safe radiotherapy delivery, and should include measurements which are independent of manufacturer-provided calibration. However, the physical and dosimetric properties of the INTRABEAM compact mobile 50 kV x-ray source are different from conventional kilovoltage therapy units and few reports describe methods for independent checks, frequencies, or tolerances for quality assurance tests. Methods: Based on the available evidence and local experience, methods are described for determination of the key dosimetric parameters: beam quality, output, isotropy, and depth doses. Internal system checks are also described, along with measurements of long-term stability. Results: A small volume parallel plate ionization chamber in a liquid water tank is the gold standard for measurements with this unit, but solid water-equivalent materials, thermoluminescent dosimeters and radiochromic film can all be used as practical alternatives with an accuracy of 5%–10%. The main cause of measurement uncertainty is positioning of the detector in the steep dose gradient, but energy dependence should also be considered. Conclusions: A quality assurance schedule with suggested tolerances is proposed, which includes both internal tests, before each treatment and on a monthly basis, and independent tests every year or after servicing or recalibration.

  1. Avaliação da qualidade de sementes de cedro (Cedrela fissilis - meliaceae pelo teste de raios X Evaluation of the seed quality in Cedrela fissilis - (meliaceae by X-ray test

    Directory of Open Access Journals (Sweden)

    Tathiana Elisa Masetto

    2008-12-01

    Full Text Available O teste de raios X tem se demonstrado uma técnica muito eficiente no controle de qualidade de sementes de espécies florestais, caracterizando fases do desenvolvimento, danos causados por secagem, beneficiamento e predação, entre outros. Objetivouse com este trabalho avaliar a qualidade física de sementes de cedro (Cedrela fissilis pelo teste de raios X. Para isso, após o beneficiamento, as sementes de cedro foram expostas às seguintes condições de intensidade de radiação e tempos (25 Kv durante 60/30 segundos e 30 Kv durante 40 segundos para determinar o padrão de raios X. De acordo com a anatomia visualizada pela imagem radiográfica, as sementes foram classificadas em Sementes Cheias, Sementes Com Danos, Sementes Mal Formadas e Sementes Vazias. Em seguida, foi realizado o teste de germinação em BOD, utilizando-se substrato de papel umedecido dentro de caixas para germinação, sob 25ºC e luz branca constante. Ao final de 20 dias, foram registrados os números de plântulas normais, anormais e sementes mortas. Pelos resultados obtidos, a intensidade de radiação de 25 Kv durante 60 segundos permitiu melhor visualização das características internas e os danos observados pela imagem radiográfica afetaram a germinação das sementes, reduzindo a qualidade do lote.The X-ray has showed to be a very efficient technique in the quality control of forest tree seeds, characterizing development phases, damages caused by dehydration, improvement and infestation, among others. The aim of this work was to evaluate the physical quality of cedar seeds (Cedrela fissilis by X-ray test. For this, the cedar seeds were exposed at the following conditions of radiation intensity and times (25 Kv during 60/30 seconds and 30 Kv during 40 seconds to determine the pattern of X-rays. According to the anatomy visualized by the radiographic image, seeds were classified in Full Seeds; Seeds With Damages, Deformed Seeds and Empty Seeds. Soon after, the

  2. Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav, E-mail: sstoupin@aps.anl.gov; Shvyd’ko, Yuri; Trakhtenberg, Emil; Liu, Zunping; Lang, Keenan; Huang, Xianrong; Wieczorek, Michael; Kasman, Elina; Hammonds, John; Macrander, Albert; Assoufid, Lahsen [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-07-27

    We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

  3. Cosmic rays and tests of fundamental principles

    Science.gov (United States)

    Gonzalez-Mestres, Luis

    2011-03-01

    It is now widely acknowledged that cosmic rays experiments can test possible new physics directly generated at the Planck scale or at some other fundamental scale. By studying particle properties at energies far beyond the reach of any man-made accelerator, they can yield unique checks of basic principles. A well-known example is provided by possible tests of special relativity at the highest cosmic-ray energies. But other essential ingredients of standard theories can in principle be tested: quantum mechanics, uncertainty principle, energy and momentum conservation, effective space-time dimensions, hamiltonian and lagrangian formalisms, postulates of cosmology, vacuum dynamics and particle propagation, quark and gluon confinement, elementariness of particles…Standard particle physics or string-like patterns may have a composite origin able to manifest itself through specific cosmic-ray signatures. Ultra-high energy cosmic rays, but also cosmic rays at lower energies, are probes of both "conventional" and new Physics. Status, prospects, new ideas, and open questions in the field are discussed.

  4. Cosmic rays and tests of fundamental principles

    International Nuclear Information System (INIS)

    Gonzalez-Mestres, Luis

    2011-01-01

    It is now widely acknowledged that cosmic rays experiments can test possible new physics directly generated at the Planck scale or at some other fundamental scale. By studying particle properties at energies far beyond the reach of any man-made accelerator, they can yield unique checks of basic principles. A well-known example is provided by possible tests of special relativity at the highest cosmic-ray energies. But other essential ingredients of standard theories can in principle be tested: quantum mechanics, uncertainty principle, energy and momentum conservation, effective space-time dimensions, hamiltonian and lagrangian formalisms, postulates of cosmology, vacuum dynamics and particle propagation, quark and gluon confinement, elementariness of particles... Standard particle physics or string-like patterns may have a composite origin able to manifest itself through specific cosmic-ray signatures. Ultra-high energy cosmic rays, but also cosmic rays at lower energies, are probes of both 'conventional' and new Physics. Status, prospects, new ideas, and open questions in the field are discussed.

  5. Quality control and batch testing of MRPC modules for BESIII ETOF upgrade

    Science.gov (United States)

    Liu, Z.; Li, X.; Sun, Y. J.; Li, C.; Heng, Y. K.; Chen, T. X.; Dai, H. L.; Shao, M.; Sun, S. S.; Tang, Z. B.; Yang, R. X.; Wu, Z.; Wang, X. Z.

    2017-12-01

    The end-cap time-of-flight (ETOF) system for the Beijing Spectrometer III (BESIII) has been upgraded using the Multi-gap Resistive Plate Chamber (MRPC) technology (Williams et al., 1999; Li et al., 2001; Blanco et al., 2003; Fonte et al., 2013, [1-4]). A set of quality-assurance procedures has been developed to guarantee the performances of the 72 mass-produced MRPC modules installed. The cosmic ray batch testing show that the average detection efficiency of the MRPC modules is about 95%. Two different calibration methods indicate that MRPCs' time resolution can reach 60 ps in the cosmic ray test.

  6. Quality image and incident air kerma evaluation in X-ray chest exams

    International Nuclear Information System (INIS)

    Campos de O, P. M.; Do Carmo S, P.; De Sousa L, M. A.; Da Silva, T. A.

    2017-10-01

    The procedures optimization for obtaining diagnostic quality images is an important factor to the patients radiation levels submitted to diagnostic radiology examinations was the lowest as reasonably practicable. Two methodologies for image quality parameters evaluation were applied in the routine of three diagnostic radiology clinics (A, B and C), two with digital image processing and one with chemical processing in Belo Horizonte, Brazil. The incident air kerma was evaluated for the radiographic techniques used in the clinic routine chest exams, approved in accordance with European Image Quality Criteria. It was possible to determine that the Fluke Biomedical X-ray Phantom test objects coupled to the Leeds Test Objects (TOR CDR) obtained better results than Gammex s Radiographic Survey Phantom (RSV), because the low and high contrast structures present in the RSV were not visualized in lower energies. The three clinics presented very similar results in all image quality parameters in the evaluation with the TOR CDR test object. However, clinic C presented an low contrast structures result 28.1 % lower than clinical B, although the average Ka,i to obtain their images was 33.4 % superior. The clinic A results present the best relation between image quality and radiation dose in patients. It was verified the optimization doses possibility in diagnostic radiology services with digital processing system, without significant reduction in image quality. Patients submitted to the highest radiation levels belonged to the clinic that presented the worst results in the image quality parameters evaluated. (Author)

  7. Radiation safety and quality in diagnostic x-ray imaging 2001

    International Nuclear Information System (INIS)

    Servomaa, A.; Parviainen, T.

    2001-05-01

    The obligations of the medical exposure directive (97/43/Euratom) for hospitals dominate the current activities in radiation protection in medical radiology. The directive gives special emphasis to radiation exposure of children, to examinations with high radiation doses and to radiation exposure in health screening programmes. The most important examinations with high doses are radiological interventions, where even acute skin effects are possible, and the computed tomography where the number of CT examinations makes only about 5% from the total number of x-ray examinations but the collective effective dose about 40% from the combined collective effective dose of all x-ray examinations. In the research projects financed by the European Commission, radiation exposures to paediatric patients have been measured in radiography, fluoroscopy and CT, and various dose assessment methods have been compared to develop a method for national follow-up of patients' radiation dose. The newest research project is focused on dosimetry and quality assurance in interventional radiology and digital imaging. Other actual topics are the development of radiation protection regulations and quality systems, education and training programmes, and clinical audits. This report deals with new radiation protection guides and recommendations and the education and training of radiological staff in radiation protection. One important topic is the development of national follow-up method of radiation exposure to patients and comparison of various dose assessment methods. Quality assurance in health care and in paediatric radiology, and the acceptance test and quality assurance measurements of radiological equipment are also described. (orig.)

  8. Hartman Testing of X-Ray Telescopes

    Science.gov (United States)

    Saha, Timo T.; Biskasch, Michael; Zhang, William W.

    2013-01-01

    Hartmann testing of x-ray telescopes is a simple test method to retrieve and analyze alignment errors and low-order circumferential errors of x-ray telescopes and their components. A narrow slit is scanned along the circumference of the telescope in front of the mirror and the centroids of the images are calculated. From the centroid data, alignment errors, radius variation errors, and cone-angle variation errors can be calculated. Mean cone angle, mean radial height (average radius), and the focal length of the telescope can also be estimated if the centroid data is measured at multiple focal plane locations. In this paper we present the basic equations that are used in the analysis process. These equations can be applied to full circumference or segmented x-ray telescopes. We use the Optical Surface Analysis Code (OSAC) to model a segmented x-ray telescope and show that the derived equations and accompanying analysis retrieves the alignment errors and low order circumferential errors accurately.

  9. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  10. Radiation safety and quality control assurance in X-ray diagnostics 1998

    International Nuclear Information System (INIS)

    Servomaa, A.

    1998-03-01

    The report is based on a seminar course of lectures 'Radiation safety and quality assurance in X-ray diagnostics 1998' organized by the Radiation and Nuclear Safety Authority (STUK) in Finland. The lectures included actual information on X-ray examinations: methods of quality assurance, methods of measuring and calculating patient doses, examination frequencies, patient doses, occupational doses, and radiation risks. Paediatric X-ray examinations and interventional procedures were the most specific topics. The new Council Directive 97/43/Euratom on medical exposure, and the European Guidelines on quality criteria for diagnostic radiographic images, were discussed in several lectures. Lectures on general radiation threats and preparedness, examples of radiation accidents, and emergency preparedness in hospitals were also included. (editor)

  11. Quality assurance in diagnostic radiology in Hungary - first experiences in acceptance testing

    International Nuclear Information System (INIS)

    Porubszky, T.; Pellet, S.; Ballay, L.; Talian, L.; Giczi, F.

    2003-01-01

    It is a general experience that optimum imaging with minimum patient doses, moreover, the safe operation and long life of X-ray equipment can be assured by regular measurement of technical parameters and checking of their constancy (routine performance testing) only. These tests are generally known as quality control, while together with the so-called corrective actions and its management it is called (physical-technical) quality assurance (QA). In the European Union, Directive 97/43/EURATOM about radiation protection of patients requires - among others - the good practice of (physical-technical) quality assurance. In Hungary, Decree No. 31/2001. (X.3.) of the Minister of Health harmonizes all of its requirements. Acceptance testing of new diagnostic X-ray equipment is assigned to NPHC-NRIRR. QA has been a daily practice in radiation therapy and nuclear medicine for a long time. A National Patient Dose Assessment Programme has also successfully run since 1989. We had, however, only few preliminaries in QA in diagnostic radiology in the second half of the eighties. Nowadays there are running QA programmes in some hospitals and mammography centres. he testing activity of our institute is independent from manufacturers, it is run within the frame of an accredited testing laboratory, using calibrated measuring instruments and based on valid international standards. So the started way of implementing QA in diagnostic radiology needs a lot of further efforts, adapting experiences of other countries, and also some financial help to reach an acceptable level in the EU. (authors)

  12. X-rays for industry: Non-destructive testing helps Malaysia’s competitiveness

    International Nuclear Information System (INIS)

    Plonsky, Brian

    2015-01-01

    Industrial testing using nuclear technology has contributed to the competitiveness of Malaysia’s manufacturing sector, industry players have said. The country has also built itself an export niche in South-East Asia, offering non-destructive testing (NDT) with nuclear devices to manufacturers in neighbouring countries. “The fact that we can get NDT services of a good quality level at a very reasonable price allows us to spend more money on inspection, and thus improve our competitiveness as well as the level of safety of our plant,” said Zamaludin Ali, senior engineer at oil company PETRONAS. Before the development of a local NDT industry and accreditation system for testing services, PETRONAS and other companies in Malaysia had to rely on foreign NDT providers, or local companies hiring operators certified abroad, he explained. NDT using nuclear techniques involves the use of ionizing radiation to test the quality of finished products. It is based on the same principle as X-rays used in hospitals. Oil pipes, boilers, pressure vessels, aircraft equipment and ships are among the products whose quality is tested with the technique. The IAEA has played an important role in helping Malaysia to establish accredited training agencies and a certification system, and to promote NDT technologies such as radiographic testing. As a result of this longstanding partnership, over 50 companies in Malaysia, employing more than 2000 technicians, are certified to carry out NDT testing.

  13. Quality control of X-ray irradiator by biological markers

    International Nuclear Information System (INIS)

    Miura, Miwa; Lukmanul Hakkim, F.; Yoshida, Masahiro; Matsuda, Naoki; Morita, Naoko

    2011-01-01

    The exposure of animals or cultured cells to radiation is the essential and common step in experimental researches to elucidate biological effects of radiation. When an X-ray generator is used as a radiation source, physical parameters including dose, dose rate, and the energy spectrum of X-ray play crucial roles in biological outcome. Therefore, those parameters are the important points to be checked in quality control and to be carefully considered in advance to the irradiation to obtain the accurate and reproductive results. Here we measured radiation dose emitted from the X-ray irradiator for research purposes by using clonogenic survival of cultured mammalian cells as a biological marker in parallel with physical dosimetry. The results drawn from both methods exhibited good consistency in the dose distribution on the irradiation stage. Furthermore, the close relationship was observed between cell survival and the photon energy spectrum by using different filter components. These results suggest that biological dosimetry is applicable to quality control of X-ray irradiator in adjunct to physical dosimetry and that it possibly helps better understanding of the optimal irradiating condition by X-ray users in life-science field. (author)

  14. Image quality testing of assembled IR camera modules

    Science.gov (United States)

    Winters, Daniel; Erichsen, Patrik

    2013-10-01

    Infrared (IR) camera modules for the LWIR (8-12_m) that combine IR imaging optics with microbolometer focal plane array (FPA) sensors with readout electronics are becoming more and more a mass market product. At the same time, steady improvements in sensor resolution in the higher priced markets raise the requirement for imaging performance of objectives and the proper alignment between objective and FPA. This puts pressure on camera manufacturers and system integrators to assess the image quality of finished camera modules in a cost-efficient and automated way for quality control or during end-of-line testing. In this paper we present recent development work done in the field of image quality testing of IR camera modules. This technology provides a wealth of additional information in contrast to the more traditional test methods like minimum resolvable temperature difference (MRTD) which give only a subjective overall test result. Parameters that can be measured are image quality via the modulation transfer function (MTF) for broadband or with various bandpass filters on- and off-axis and optical parameters like e.g. effective focal length (EFL) and distortion. If the camera module allows for refocusing the optics, additional parameters like best focus plane, image plane tilt, auto-focus quality, chief ray angle etc. can be characterized. Additionally, the homogeneity and response of the sensor with the optics can be characterized in order to calculate the appropriate tables for non-uniformity correction (NUC). The technology can also be used to control active alignment methods during mechanical assembly of optics to high resolution sensors. Other important points that are discussed are the flexibility of the technology to test IR modules with different form factors, electrical interfaces and last but not least the suitability for fully automated measurements in mass production.

  15. Gamma ray induced fruit quality variations in banana variety Nendran (Musa Paradasiaca L.)

    International Nuclear Information System (INIS)

    Radha Devi, D.S.; Nayer, N.K.

    1992-01-01

    Gamma ray induced fruit quality variation was envisaged to analyse the direct effect of Co 60 gamma rays in banana variety Nendran. Fruit quality analysis showed that the total soluble solids and acidity decreased and total sugar and sugar acid ratio increased with increase in dose of gamma ray exposures. (author). 5 refs., 1 tab

  16. Cosmic-ray test and temperature effects of MRPC

    International Nuclear Information System (INIS)

    Yue Qian; Li Yuanjing; Cheng Jianping; Wang Yi; Li Jin; Lai Yongfang; Li Qinghua; Tang Le

    2004-01-01

    A comic-ray test system has been built for testing the performance of MRPC modules. Some methods have been studied to improve the time resolution of the cosmic-ray test based on this testing system. The time resolutions of about 84 ps and 75 ps can be achieved for MRPC and its reference time, respectively. The temperature effects of MRPC have also been researched and some useful results are obtained. (author)

  17. Microfocus X-ray imaging of Brazil nuts for quality control

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Margareth Kazuyo Kobayashi Dias, E-mail: mkfranco@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Yokaichiya, Fabiano, E-mail: fabiano.yokaichiya@helmholtz-berlin.de [Department Quantum Phenomena in Novel Materials, Helmholtz Zentrum Berlim für Materialien und Energie GmbH, Berlin (Germany); Kardjilov, Nikolay, E-mail: kardjilov@helmholtz-berlim.de [Institut Angewandte Materialforschung, Helmholtz Zentrum Berlim für Materialien und Energie GmbH, Berlin (Germany); Ferraz, Antonio Carlos de Oliveira, E-mail: carlos@feagri.unicamp.br [Universidade Estadual de Campinas (FEAGRI/UNICAMP), SP (Brazil). Faculdade de Engenharia Agricola

    2015-07-15

    Non-destructive quality assessment of food prior to processing is desirable in commercial facilities due to its non-invasive nature, for economic reasons and for its safety appeals. Grading Brazil nuts in this way allows for the separation of undesirable nuts to avoid contamination during the automatic nut shelling process. The aim of this study was to evaluate the feasibility of X-ray phase contrast enhanced imaging in assessing nut quality. For this goal, details of the imaging technique are described and phase contrast X-ray and microtomography imaging of nut samples are investigated. Both high quality (i.e. 'sound' nuts as well as treated nuts were examined. It was concluded that both the X-ray imaging and tomography techniques have the potential to discriminate morphological features of the nut and to identify 'sound' kernels from atypical ones. Larger nuts and nuts with a larger gap area between shell and kernel were concluded to have more atypical formations. Both techniques also seemed promising for use in automatic sorting lines. However, by using microtomography, the visualization of finer formations not noticeable in the X-ray images was possible. Further studies shall be carried out to investigate the nature of these formations, how they affect nut quality and their evolution with storage time. (author)

  18. Microfocus X-ray imaging of Brazil nuts for quality control

    International Nuclear Information System (INIS)

    Franco, Margareth Kazuyo Kobayashi Dias; Yokaichiya, Fabiano; Kardjilov, Nikolay; Ferraz, Antonio Carlos de Oliveira

    2015-01-01

    Non-destructive quality assessment of food prior to processing is desirable in commercial facilities due to its non-invasive nature, for economic reasons and for its safety appeals. Grading Brazil nuts in this way allows for the separation of undesirable nuts to avoid contamination during the automatic nut shelling process. The aim of this study was to evaluate the feasibility of X-ray phase contrast enhanced imaging in assessing nut quality. For this goal, details of the imaging technique are described and phase contrast X-ray and microtomography imaging of nut samples are investigated. Both high quality (i.e. 'sound' nuts as well as treated nuts were examined. It was concluded that both the X-ray imaging and tomography techniques have the potential to discriminate morphological features of the nut and to identify 'sound' kernels from atypical ones. Larger nuts and nuts with a larger gap area between shell and kernel were concluded to have more atypical formations. Both techniques also seemed promising for use in automatic sorting lines. However, by using microtomography, the visualization of finer formations not noticeable in the X-ray images was possible. Further studies shall be carried out to investigate the nature of these formations, how they affect nut quality and their evolution with storage time. (author)

  19. [Problems of the effective energy used as a quality expression of diagnostic X-ray].

    Science.gov (United States)

    Kato, Hideki; Hayashi, Naoki; Suzuki, Shoichi; Ando, Sho; Miyamoto, Mami; Wakasugi, Nao; Suzuki, Shizuma

    2011-01-01

    The effective energy has been generally used as a method of handily expressing an X-ray quality by one numerical value. The effective energy is a concept derived from "Half Value Layer (HVL)" that is the expressing parameter of beam quality based on the attenuation of the primary X-ray by a material. When beam quality is expressed by using HVL and / or the effective energy, it is necessary to describe the tube potential, the rectification method, and the homogeneity coefficient, etc. in parallel. However, recently feelings are that the effective energy should be handled like an absolute numerical value to physical characteristics of X-rays. In this paper, it was theoretically clarified that the effective energy had a different value depending on the absorber material used for the HVL measurement. In addition, the errors when physical characteristics of the X-rays were evaluated using the effective energy was also examined. Physical characteristics, such as interactions to the material of mono-energetic X-ray, are not equal to that of X-rays with a wide energy spectrum. It is not an easy comparison to express the quality of the diagnostic X-rays, and to calculate physical characteristics of the X-rays by using the effective energy. It is necessary to design a new method of expressing the quality of X-rays that takes the place of the "effective energy."

  20. Facility for testing and certification of medical x-ray films at BARC

    International Nuclear Information System (INIS)

    Sharma, Reena; Jayalakshmi, V.; Nair, C.P.R.

    2006-12-01

    The major problem faced in the x-ray department with regard to x-ray films is the non consistent image quality of x-ray films leading to lesions missed/ wrong diagnosis and as a result retakes of the examination and increased radiation dosage to the patient. This report illustrates the methodology adopted by this Division towards implementation of quality assurance of the basic imaging devices namely the medical x-ray films. The characteristics properties desirable in x-ray films are the qualitative response of the emulsion to standard set of exposure and processing conditions in terms of speed, contrast and density. It should be consistent for exposure conditions in a custom built equipment simulating the quantum and type of energy that would be received by the film during diagnostic examinations. The phantom, geometrical set up and beam quality specifications as per the ISO standards required for x-ray sensitometry have been described in this report. (author)

  1. Physical-technical quality control for medical x-ray apparatus

    International Nuclear Information System (INIS)

    Aalbers, A.H.L.

    1989-01-01

    The technical aspects of quality control in medial x-ray diagnostics are discussed. It is recommended to hurry, also in the Netherlands, on the basis of already existing starting-up's abroad, with drawing up quality standards and judgement criteria. (author). 6 refs.; 2 figs.; 1 tab

  2. Quality assessment of the digitalization process of analog x-ray images

    International Nuclear Information System (INIS)

    Georgieva, D.

    2014-01-01

    Computer-assisted diagnosis enabled doctors for a second point-of-view on the test results. This improves the diseases' early detection and significantly reduces the chance of errors. These methods very nicely complemented the possibilities of digital medical imaging apparatus, but in analog images their applicability and results entirely depend on the quality of analog images digitalisation. Today many standards and remarks for good practices discuss the digital apparatus image quality but the digitalisation process of analog medical images is not a part of them. Medical imaging apparatus have become digital, but within an entirely digital medical environment is necessary for their ability to blend with the old analog medical imaging carriers. The life of patients doesn't start with the beginning of digital era and for the aim of tracking diseases it is necessary to use the new digital images as well as older analog ones. For the generation of 40-50 years a large archive of images is piled up, which should be accounted of in the diagnosis process. This article is the author's study of the digitalized image quality problem. It offers a new approach to the x-ray image digitalisation - getting the HDR-image by optical sensor. After the HDR-image generation method offers to be used a digital signal processing to improve the quality of the final 16 bit gray scale medical image. The new method for medical image enhancement is proposed - it improves the image contrast, it increases or preserves the dynamic range and it doesn't lead to the loss of small low contrast structures in the image. Key words: Quality of Digital X-Rays Images

  3. Image quality of medical X-ray systems

    International Nuclear Information System (INIS)

    Hoen, P.J. 't.

    1980-01-01

    The quality of images made by medical X-ray systems can only be properly described if the visual system is also taken into account. In this thesis, the visual threshold contrast of edges, bars and disks has been chosen as the criterion. Since these objects resemble medical objects like tumour-mass outlines, blood vessels and micro-calcifications, a correlation with X-ray practice is possible. Only the conventional X-ray systems are considered, but a brief analysis of computerized tomography is given. Considerable attention is paid to unsharpness and the minimization of its influence on the threshold contrast, to the influence of the noise on the threshold contrast, and to the contrast formation as such. The consequences for the dose administered to the patient are also briefly analysed. (Auth.)

  4. Quality control assessment of diagnostic x-ray facilities in Ghana

    International Nuclear Information System (INIS)

    Amoako, J.K.; Charles, D.F.; Oppong-Adu, C.; Schandorf, C.

    2009-01-01

    Twenty-three X-ray machines located at 20 different hospitals in Ghana were assessed for quality assurance and control. The radiographic parameters evaluated were tube voltage and current, tube output consistency variation with kilovoltage (kV) and current-time (mAs) factor, exposure time accuracy and beam quality as measured by half-value layer. The photographic parameters assessed were type of films, level of film fogging, film speed, contrast index and film processing temperature. Twenty two of the machines were ∼ 99 % output consistency with standard kVp and mAs. Twelve of the machines had output linearity deviation of less than the acceptable 5 %, while 22 machines were within the accepted kVp deviation of 5 %. The film processing temperature at most hospitals exceeded the required level, due to the absence of air conditioners in the darkrooms. The darkroom quality control at all the facilities was very high. Fogging of films was minimal as indicated by the Base + Fog value of 0.3, speed index of film was ∼ 1.65 and contrast index was comparable to the acceptable value of 1.5. The level of timer accuracy was greater than 95 % for all the X-ray machines with the exception of one. The general quality control status of all the X-ray machines and darkrooms assessed were acceptable and within the quality assurance standards. (au)

  5. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from equipment suppliers of manufacturers in new and existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing quality status of the equipment. A working group has developed guidelines for these acceptance tests. Items to be measured are reported and proposed limiting values and their tolerances are discussed. (author)

  6. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from the equipment suppliers or manufacturers in new and also existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing the quality status of the equipment. A working group has developed guidelines for these acceptance tests. The items to be measured are reported and the proposed limiting values and their tolerances are discussed. (author)

  7. Skin Reactions and Quality of Life after X-Ray Therapy of Basal Cell Carcinoma

    International Nuclear Information System (INIS)

    Skiveren, J.; Daugbjerg, H.; Wulf, H. C.; Mikkelsen, M. R.

    2012-01-01

    Background. Advanced basal cell carcinoma (BCC) is often treated by surgery or X-ray therapy. The consequences of X-ray therapy on the patients health-related quality-of-life (HRQOL) have so far not been described. Objectives. To quantify quality of life in BCC patients before and after X-ray therapy compared with matched healthy controls. Materials. Twenty-five patients (mean age 69) with BCC completed the Dermatology Life Quality Index (DLQI) before and two weeks and three months after X-ray therapy and their results were compared with the DLQI scores for 25 matched controls. Results. Compared to the healthy controls the patients' DLQI score was significantly higher before and 2 weeks after X-ray therapy ( ρ=0.005;ρ=0.000). The patients' DLQI score decreased significantly from baseline to three months after X-ray therapy (ρ=0.024), when it became similar to that of the healthy controls (ρ=0.819). Three months after X-ray therapy eight patients had no skin reactions, 11 had slight atrophy, pigmentation change, and/or some hair loss, four had patch atrophy, moderate telangiectasia, and/or total hair loss. Conclusions. BCC has a negative effect on patients' quality of life. The study shows that HRQOL normalises shortly after X-ray therapy, despite minor skin manifestations.

  8. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  9. Quality management systems in radiology

    Directory of Open Access Journals (Sweden)

    Geoffrey K. Korir

    2013-08-01

    Objective: To assess the level of quality management systems in X-ray medical facilities in Kenya. Methods: Quality management inspection, quality control performance tests and patient radiation exposure were assessed in 54 representative X-ray medical facilities. Additionally, a survey of X-ray examination frequency was conducted in 140 hospitals across the country. Results: The overall findings placed the country’s X-ray imaging quality management systems at 61±3% out of a possible 100%. The most and the least quality assurance performance indicators were general radiography X-ray equipment quality control tests at 88±4%, and the interventional cardiology adult examinations below diagnostic reference level at 25±1%, respectively. Conclusions: The study used a systematic evidence-based approach for the assessment of national quality management systems in radiological practice in clinical application, technical conduct of the procedure, image quality criteria, and patient characteristics as part of the quality management programme.

  10. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment; Desenvolvimento de um dispositivo artesanal para os testes de colimação e alinhamento do raio central em equipamentos médicos de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S., E-mail: elizabethberbr@live.com [Universidade José de Souza Herdy (UNINGRANRIO), Nova Iguaçu, RJ (Brazil)

    2017-07-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden.

  11. German standard and German X-ray guide lines as a guide for quality assurance in X-ray diagnosis

    International Nuclear Information System (INIS)

    Pychlau, P.

    1985-01-01

    The German standard DIN 6868 (in preparation) and parts of the German X-ray Ordinance of 1973 deal with quality assurance in X-ray diagnosis. It is shown that both documents support each other and are a guidance for daily work. (author)

  12. Quality control procedure for a general diagnostic x-ray machine

    International Nuclear Information System (INIS)

    Md Saion Salikin; Mazlyfarina Mohamad

    2001-01-01

    Performance tests of a particular medical diagnostic x-ray machine have to be carried out regularly in order to ensure that the machine always complies with the required standard. A performance report which is prepared based on the performance tests on the x-ray machine is used as one of the requirement by the authority for issuance and renewal licence to operate and use of the x-ray machine in a clinic or hospital. The Ministry of Health will only issue a licence to the clinic or hospital to use and operate x-ray machines, if the machines have complied with the standards. The clinic or hospital may get the service to carry out performance tests on a diagnostic x-ray machine from any licence H holder, issued by the authority under Atomic Energy Licensing Act 1984. A comparative study between the standard procedure and other procedures on performance test of a general diagnostic x-ray machine is carried out and presented in brief in this paper. The criteria for compliance or otherwise as required by the Ministry of Health Malaysia is discussed and explained in brief. (Author)

  13. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization

    International Nuclear Information System (INIS)

    Holmes, D.R. Jr.; Bove, A.A.; Wondrow, M.A.; Gray, J.E.

    1986-01-01

    A newly developed video x-ray progressive scanning system improves image quality, decreases radiation exposure, and can be added to any pulsed fluoroscopic x-ray system using a video display without major system modifications. With use of progressive video scanning, the radiation entrance exposure rate measured with a vascular phantom was decreased by 32 to 53% in comparison with a conventional fluoroscopic x-ray system. In addition to this substantial decrease in radiation exposure, the quality of the image was improved because of less motion blur and artifact. Progressive video scanning has the potential for widespread application to all pulsed fluoroscopic x-ray systems. Use of this technique should make cardiac catheterization procedures and all other fluoroscopic procedures safer for the patient and the involved medical and paramedical staff

  14. Quality assessment of coffee beans with ESR and gamma-ray irradiation

    International Nuclear Information System (INIS)

    Ikeya, Motoji; Baffa, F.O.; Mascarenhas, Sergio

    1989-01-01

    Peroxy radical formation in raw coffee beans of different qualities and origins from all over the world has been studied with electron spin resonance (ESR) analysis. The γ-ray equivalent absorbed dose (ED) which creates the same concentration of radicals is obtained by the additive γ-ray irradiation of the coffee beans. The ED and the cup quality is somewhat inversely related suggesting that the peroxidation of the unsaturated fatty acid is somewhat indicative of the degree of the aromatic decomposition and rancidity. (author)

  15. Quality control for dental X-rays equipment and film developers

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1998-01-01

    Quality control in five dental X-ray equipments, film and film developers was done. It was for evaluating the radiologic practices in the odontologic services too. This work was made based on international standards, the results will be used for future works in quality assurance in dental radiology

  16. X-ray Computed Tomography Image Quality Indicator (IQI) Development

    Data.gov (United States)

    National Aeronautics and Space Administration — Phase one of the program is to identify suitable x-ray Computed Tomography (CT) Image Quality Indicator (IQI) design(s) that can be used to adequately capture CT...

  17. Quality control assessment of diagnostic X-ray facilities in Ghana ...

    African Journals Online (AJOL)

    Twenty-three X-ray machines located at 20 different hospitals in Ghana were assessed for quality assurance and control. The radiographic parameters evaluated were tube voltage and current, tube output consistency variation with kilovoltage (kV) and current-time (mAs) factor, exposure time accuracy and beam quality as ...

  18. Soft X-ray Foucault test: A path to diffraction-limited imaging

    Science.gov (United States)

    Ray-Chaudhuri, A. K.; Ng, W.; Liang, S.; Cerrina, F.

    1994-08-01

    We present the development of a soft X-ray Foucault test capable of characterizing the imaging properties of a soft X-ray optical system at its operational wavelength and its operational configuration. This optical test enables direct visual inspection of imaging aberrations and provides real-time feedback for the alignment of high resolution soft X-ray optical systems. A first application of this optical test was carried out on a Mo-Si multilayer-coated Schwarzschild objective as part of the MAXIMUM project. Results from the alignment procedure are presented as well as the possibility for testing in the hard X-ray regime.

  19. Quality assurance in X-ray medical diagnosis - a physicist's viewpoint

    International Nuclear Information System (INIS)

    Moores, B.M.

    1985-01-01

    The role of quality assurance in the overall framework of costs, risks and benefits in X-ray medical diagnosis is outlined. Justification for implementing quality assurance is highlighted in terms of the nature and extent of radiological practice, the levels of exposure involved and the cost of providing the service. Quality assurance is discussed in terms of (i) quantitation/assessment; (ii) administration/ management; (iii) organisation; (iv) implementation. In particular, the need to implement quality assurance cost-effectively is discussed. (author)

  20. Automatic TV X-ray unit for testing aluminium castings

    International Nuclear Information System (INIS)

    Morgunov, V.I.; Firstov, V.G.; Kisin, V.I.; Savostenok, M.I.

    1989-01-01

    The automatic TV X-ray unit for testing of aluminum alloy castings in a flow is described. The unit includes RAP-150/300 X-ray apparatus and PI-60TK TV X-ray device. The biological protection chamber and the common control board are the main functional units. The tests of the unit have shown that as regards its characteristics it is not worse than its foreign-made analogues, for example, devices of the DP-35 and DP-38 type of the 'Seifert' company

  1. Crystal quality analysis and improvement using x-ray topography

    International Nuclear Information System (INIS)

    Maj, J.; Goetze, K.; Macrander, A.; Zhong, Y.; Huang, X.; Maj, L.

    2008-01-01

    The Topography X-ray Laboratory of the Advanced Photon Source (APS) at Argonne National Laboratory operates as a collaborative effort with APS users to produce high performance crystals for APS X-ray beamline experiments. For many years the topography laboratory has worked closely with an on-site optics shop to help ensure the production of crystals with the highest quality, most stress-free surface finish possible. It has been instrumental in evaluating and refining methods used to produce high quality crystals. Topographical analysis has shown to be an effective method to quantify and determine the distribution of stresses, to help identify methods that would mitigate the stresses and improve the Rocking curve, and to create CCD images of the crystal. This paper describes the topography process and offers methods for reducing crystal stresses in order to substantially improve the crystal optics.

  2. Investigation of clinical conditions affecting quality control in a dental X-ray unit

    International Nuclear Information System (INIS)

    Akiyama, Hironori; Koseki, Takakazu; Itagaki, Keisuke; Yotsui, Yoritaka; Gamoh, Shoko; Shimizutani, Kimishige

    2011-01-01

    In this study, to clarify quality control issues in a dental X-ray unit, we surveyed the uniformity and safety of absorbed doses and exposure time from dental X-ray units, and evaluated image quality of intraoral radiography at Osaka Dental University Hospital. Measurements of dose and exposure time were carried out five times and the mean was calculated at twenty-two dental X-ray units in our university hospital using the standard parameters for the mandibular molar region in adults. Intraoral radiography for evaluation of image quality was taken using D-speed films under the standard parameters for the mandibular molar region in adults and E-speed films for pediatric patients. Evaluation of image quality was performed by three oral radiologists. Dose and exposure time differed significantly among units. Image quality of intraoral radiography using D-speed films was not significantly better than that of E-speed films. This study demonstrated that it is necessary to establish a uniform dose and exposure time and to change D-speed films to E-speed films when obtaining intraoral radiography in our hospital. (author)

  3. Characterization of radiation qualities used in diagnostic X-ray

    International Nuclear Information System (INIS)

    Bero, M.; Zahili, M.; Al Ahmad, M.

    2013-12-01

    This study aims to adjust the radiation beams emitted from X-ray tubes installed at the National Radiation Metrology Laboratory in the field of diagnostic radiology (radiology and mammography) according to the IAEA protocol code number TRS 457, the second goal of this study is to establish various radiation qualities used fordiagnostic radiology applications: RQR, RQA and RQT and the radiation qualities related to mammography applications: RQA-M and RQR-M (author).

  4. An analysis of the ArcCHECK-MR diode array's performance for ViewRay quality assurance.

    Science.gov (United States)

    Ellefson, Steven T; Culberson, Wesley S; Bednarz, Bryan P; DeWerd, Larry A; Bayouth, John E

    2017-07-01

    The ArcCHECK-MR diode array utilizes a correction system with a virtual inclinometer to correct the angular response dependencies of the diodes. However, this correction system cannot be applied to measurements on the ViewRay MR-IGRT system due to the virtual inclinometer's incompatibility with the ViewRay's multiple simultaneous beams. Additionally, the ArcCHECK's current correction factors were determined without magnetic field effects taken into account. In the course of performing ViewRay IMRT quality assurance with the ArcCHECK, measurements were observed to be consistently higher than the ViewRay TPS predictions. The goals of this study were to quantify the observed discrepancies and test whether applying the current factors improves the ArcCHECK's accuracy for measurements on the ViewRay. Gamma and frequency analysis were performed on 19 ViewRay patient plans. Ion chamber measurements were performed at a subset of diode locations using a PMMA phantom with the same dimensions as the ArcCHECK. A new method for applying directionally dependent factors utilizing beam information from the ViewRay TPS was developed in order to analyze the current ArcCHECK correction factors. To test the current factors, nine ViewRay plans were altered to be delivered with only a single simultaneous beam and were measured with the ArcCHECK. The current correction factors were applied using both the new and current methods. The new method was also used to apply corrections to the original 19 ViewRay plans. It was found the ArcCHECK systematically reports doses higher than those actually delivered by the ViewRay. Application of the current correction factors by either method did not consistently improve measurement accuracy. As dose deposition and diode response have both been shown to change under the influence of a magnetic field, it can be concluded the current ArcCHECK correction factors are invalid and/or inadequate to correct measurements on the ViewRay system. © 2017 The

  5. Quality control procedure for dental x-ray film processing

    International Nuclear Information System (INIS)

    Tingey, D.R.C.

    1983-08-01

    Methods of obtaining the optimum processing from dental films are discussed. A method of quality control of developing conditions for dental x-ray films has been developed. It is relatively easy to maintain and is sufficiently accurate for practical purposes

  6. Reduction of patient doses in X-ray diagnosis using quality control tests on image and equipment

    International Nuclear Information System (INIS)

    Milu, C.; Tomulescu, V.; Sorescu, Anca; Vladareanu, M.; Olteanu, B.; Enachescu, B.; Zaharia, N.; Lesaru, M.

    1997-01-01

    In the frame of a research program under the contract with the International Atomic Energy Agency (IAEA), several patient dose measurements were performed using thermoluminescent dosemeters (TLDs) before and after application of Quality Control tests and patient dose reduction methods. The paper evidenced the practical influence factors (like the need of use of high voltage technique) and possibilities for dose reduction keeping the image quality. (authors)

  7. Precision test method by x-ray absorbent clay

    International Nuclear Information System (INIS)

    Nakadai, Toru; Matsukawa, Hideyuki; Sekita, Jun-ichiro; Murakoshi, Atsushi.

    1982-01-01

    In X-ray penetration photography of such as welds with reinforcing metal and castings of complex shape, the X-ray absorbent clay developed to eliminate various disadvantages of the conventional absorbents was further studied for better application. The results of the usage are as follows. Because the X-ray absorbent is clay, it is flexible in form, and gives good adhesion to test objects. In the welds and castings mentioned, it is effective for reducing the scattered ray, accordingly, it results in superior images. The following matters are described: contrast in radiographs, the required conditions for X-ray absorbents in general, the properties of the absorbent (absorption coefficient, consistency, density), improvement in radiographs by means of the X-ray absorbent clay (wall thickness compensation, masking, the application together with narrow-field irradiation photography). (Mori, K.)

  8. Compliance and quality control monitoring of diagnostic X-ray facilities in Dar es Salaam city, Tanzania

    Energy Technology Data Exchange (ETDEWEB)

    Nkuba, Leonid L.; Nyanda, Pendo B., E-mail: leonid.nkuba@taec.or.tz [Tanzania Atomic Energy Commission, Radiation Control Directorate, Dar es Salaam (Tanzania, United Republic of)

    2017-09-01

    The compliance evaluation and quality control measurements on 60 diagnostic X-ray units were performed. The results on legal compliance show that 25 % of X-ray facilities operated without or with an expired license. The rest of the centers were new and had already applied for license and others had valid licenses. For basic requirements compliance, 47 % of X-ray facilities did not have the changing cubicles, 37 % of X-ray facilities did not post radiation warning sign and symbols also 46 % of units were found either without protective gear or operated by unqualified personnel. The QC test results showed that 93 % had X-ray tube voltage within the tolerance limit of 10 % and HVL ≥ 2.3 mmAl, at 80 kV was observed in 98.2 % of the units, whereas 98 % of exposure had acceptable kV reproducibility within the tolerance limit of 5 %. Of the X-ray generators assessed, 93 % had tolerable mAs linearity. 93 % and 97 % had acceptable beam alignment and light beam diaphragm. Of the assessed units, 13 (93 %) had tube leakage < 1000 μGy/hr at 1m. For shielding tests, 47 % of units had radiation levels above 0.5 μSv/hr at the main door leading to the X-ray rooms and the registration area. The dose rates > 10 μSv/hr were recorded at viewing windows, walls and doors of control cubicles and behind the doors of changing cubicles. These dose rates indicating higher health risk to workers and member of public. (author)

  9. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  10. Device for the automatic X-ray testing of welded joints of pipes

    International Nuclear Information System (INIS)

    Ries, K.; Hannoschieck, K.; Rozic, K.M.; Basler, G.

    1979-01-01

    The notification flows of the tested pipes determined by the ultrasonic inspection are transmitted to the X-ray film automatic charger in the X-ray test room. The roll table for the pipes from the ultrasonic inspection to the X-ray test room is provided with an arrangement for weld detection and tube lathe, so that the X-ray films can be set on the corresponding spot by means of a cantilever. (RW) [de

  11. Study on the quality assurance of diagnostic X-ray machines and assessment of the absorbed dose to patients

    Science.gov (United States)

    Hassan, G. M.; Rabie, N.; Mustafa, K. A.; Abdel-Khalik, S. S.

    2012-09-01

    Radiation exposure and image quality in X-ray diagnostic radiology provide a clear understanding of the relationship between the radiation dose delivered to a patient and image quality in optimizing medical diagnostic radiology. Because a certain amount of radiation is unavoidably delivered to patients, this should be as low as reasonably achievable. Several X-ray diagnostic machines were used at different medical diagnostic centers in Egypt for studying the beam quality and the dose delivered to the patient. This article studies the factors affecting the beam quality, such as the kilo-volt peak (kVp), exposure time (mSc), tube current (mAs) and the absorbed dose in (μGy) for different examinations. The maximum absorbed dose measured per mAs was 594±239 and 12.5±3.7 μGy for the abdomen and the chest, respectively, while the absorbed dose at the elbow was 18±6 μGy, which was the minimum dose recorded. The compound and expanded uncertainties accompanying these measurements were 4±0.35% and 8±0.7%, respectively. The measurements were done through quality control tests as acceptance procedures.

  12. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  13. Trabecular bone analysis in CT and X-ray images of the proximal femur for the assessment of local bone quality.

    Science.gov (United States)

    Fritscher, Karl; Grunerbl, Agnes; Hanni, Markus; Suhm, Norbert; Hengg, Clemens; Schubert, Rainer

    2009-10-01

    Currently, conventional X-ray and CT images as well as invasive methods performed during the surgical intervention are used to judge the local quality of a fractured proximal femur. However, these approaches are either dependent on the surgeon's experience or cannot assist diagnostic and planning tasks preoperatively. Therefore, in this work a method for the individual analysis of local bone quality in the proximal femur based on model-based analysis of CT- and X-ray images of femur specimen will be proposed. A combined representation of shape and spatial intensity distribution of an object and different statistical approaches for dimensionality reduction are used to create a statistical appearance model in order to assess the local bone quality in CT and X-ray images. The developed algorithms are tested and evaluated on 28 femur specimen. It will be shown that the tools and algorithms presented herein are highly adequate to automatically and objectively predict bone mineral density values as well as a biomechanical parameter of the bone that can be measured intraoperatively.

  14. A status report on dual energy x-ray absorptiometry quality control in Korea

    International Nuclear Information System (INIS)

    Kim, Jung Su; Ro, Young Hoon; Lee, In Ju; Kim, Jung Min; Kim, Sung Su; Kim, Kyoung Ah

    2016-01-01

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude

  15. A status report on dual energy x-ray absorptiometry quality control in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su [Dept. of Radiogic Technology, Chungbuk Health and Science University, Cheongju (Korea, Republic of); Ro, Young Hoon; Lee, In Ju; Kim, Jung Min [Dept. of Bio-convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); Kim, Sung Su [Dept. of Healthcare Management, Cheongju University, Cheongju (Korea, Republic of); Kim, Kyoung Ah [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-12-15

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

  16. Segmentation of Overlapping Shapes using Test Ray Intersections

    DEFF Research Database (Denmark)

    Rasmusson, Allan

    As the use of digital images have become standard in everyday bioimaging, people are naturally trying to utilize computer algorithms for automating laborious and repetetive image analysis tasks. A preliminary task is the segmentation of structures of interest from digital images. This may in itself....... This may, however, quickly lead to the implementation of complex descriptions of any possible configuration the overlapping shapes may appear in. Presented here is a new approach to segment overlapping shapes which utilizes information gained from probing the image with test rays. Test rays intersections...

  17. Fully automatic X-ray testing in monitoring manufacture - theoretical background and practical experience

    International Nuclear Information System (INIS)

    Roye, W.; Kosanetzky, J.

    1992-01-01

    The trend to ever-increasing automation has not passed by industrial X-ray test technique. As in other fields, there is a development away from manual testing via automated island solutions to including the X-ray test in comprehensive CIM concepts. Wholly new requirements are made of industrial X-ray technique here. High certainty of testing with exact determination of faults and measurements, high test speed by quick handling of the test samples, statistical evaluation with the possibility of process control and sufficient flexibility of the test system are just some of the characteristics of future X-ray test systems. (orig.) [de

  18. Evaluation of the quality parameters of mobile X-ray units equipment used for radiodiagnostic in public institutions of Sergipe

    International Nuclear Information System (INIS)

    Oliveira, Celso A.; Santos, Lucas R. dos; Silva, Fabio A.R.; Souza, Divanizia N.

    2008-01-01

    This project was started having as main objective to observe the diagnosis quality offered by mobile x-ray units utilized in a health care institution. In this work we are reporting the first results obtained from three equipment used by a public institution inspected on the state of Sergipe, Brazil. During the verification visits at institution the radiology technicians were questioned about specific maintenances performed on the equipment and the operating procedures used. Moreover, some beams parameters were verified as dose, dose rate, and peak voltage and exposition time. The obtained results showed a good index of reproducibility and linearity of the operation parameters, of the kerma air rate and exposition time. However, to the kVp tests were observed variations up to 20% between the nominal value used and the value measured on the X-ray units. The test results of the focal point are in accordance with the acceptable standards. The analyses of equipment and the answered questionnaire showed that have not been performed periodic maintenances in the equipment, therefore some of the equipment do not present satisfactory requirements of operating, their do not make use of luminous field nether collimator or the scale meter to checking the source to surface distance. The main factor that can explains the negative results is the absence of a continue quality program associated with the unsatisfactory maintenances. The health care institutions evaluated are introducing a permanent quality program to the X-ray devices. (author)

  19. Paediatric x-ray radiation dose reduction and image quality analysis.

    Science.gov (United States)

    Martin, L; Ruddlesden, R; Makepeace, C; Robinson, L; Mistry, T; Starritt, H

    2013-09-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.

  20. Paediatric x-ray radiation dose reduction and image quality analysis

    International Nuclear Information System (INIS)

    Martin, L; Ruddlesden, R; Mistry, T; Starritt, H; Makepeace, C; Robinson, L

    2013-01-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%–55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children. (paper)

  1. Establishment of standard x-ray qualities to be used in diagnostic level at SSDLs

    International Nuclear Information System (INIS)

    A-Aziz, R.O.

    2007-08-01

    The objective of the present work is to modify x-ray machine (used by the secondary standard dosimetry laboratory in Sudan) to produce x-ray qualities suitable for the calibration at diagnostic level. It based on experimental evaluations. The importance of this study appears in development of protocols to calibrate the instruments used in diagnostic radiology in by good response of the instruments and low cost. In particular, the half value layer (HVL) values for the following qualities 40, 60, 80, 100, 120 and 150 were determined using various attenuation layers. Ionization chamber was used to determine the free air kerma rate at a distance of 100 cm from the x-ray generator. The obtained HVL values were compared with standard values of diagnostic levels. It was observed that the HVL of the present x-ray machine in most qualities are smaller than the standard ones. An approved method (described in the standard IEC 61267) was applied to determine the amount of additional filtration required to meet the standard values. The results show that the available cupper layers were not suitable for this purpose as most of the x-ray was absorbed in the material. Aluminum layers, on the other hand , show good performances to reduce the beams to the desired levels. The amount of additional filtration (from aluminum layers) needed in order to establish standard x-ray qualities to be used in diagnostic level were determined.(Author)

  2. The safety of food products requires X-ray testing

    International Nuclear Information System (INIS)

    Lardiere, C.

    2017-01-01

    Food safety through standards and regulations imposes food products to be tested for the presence of alien elements. So far metal detectors have been used to detect metal parts, now they have been progressively replaced with X-ray scanners that allow the detection of a lot more contaminants. The improvement of algorithms for image processing combined with the availability of ever more powerful PC have led to the routine use of X-ray testing on industrial processes. Technological progress has made X-ray testing more efficient: while previously a power of 500 W was necessary to cross a 10 cm thickness of water, now only 100 W is necessary. The main advantage of X-ray testing is to be able to test food even packed in metal containers and to detect if the container is deformed. Another advantages is to be able to detect a lot of elements like pieces of glass, small stones or bits of bones. The minimal size to be detected is 0.5 mm for stainless steels and 2 mm for glass or bones. Usually metal detectors are set at the end of the production line just before packaging but in some cases they can be included in the line in order to protect the next machine that intervenes to process the food. (A.C.)

  3. Long-term stability of beam quality and output of conventional X-ray units.

    Science.gov (United States)

    Fukuda, Atsushi; Matsubara, Kosuke; Miyati, Tosiaki

    2015-01-01

    Conventional diagnostic X-ray units are used for radiographic imaging in many countries. For obtaining entrance surface doses, a numerical dose determination method has been applied in Japan. Although this technique is effective, it has to account for errors, particularly fluctuations, due to the beam quality and output of X-ray tubes. As a part of our quality control procedures, we recorded the entrance surface air kerma, tube voltage, and half-value layer measurements made for four diagnostic X-ray tubes over a 103-week period. The entrance surface air kerma for one of the four X-ray tubes had increased significantly by 11.4 % over 1 year from its initial setting, whereas the tube voltages and half-value layers did not deviate significantly from their initial values. Medical physicists and radiological technologists should be aware of this fluctuation for diagnostic X-ray tubes and take it into consideration when calculating the entrance surface air kerma.

  4. Feature-based analysis for quality assessment of x-ray computed tomography measurements

    International Nuclear Information System (INIS)

    Nardelli, Vitor C; Arenhart, Francisco A; Donatelli, Gustavo D; Porath, Maurício C; Niggemann, Christian; Schmitt, Robert

    2012-01-01

    This paper presents an approach to assess the quality of the data extracted with computed tomography (CT) measuring systems to perform geometrical evaluations. The approach consists in analyzing the error features introduced by the CT measuring system during the extraction operation. The analysis of the features is performed qualitatively (using graphical analysis tools) and/or quantitatively (by means of the root-mean-square deviation parameter of the error features). The approach was used to analyze four sets of measurements performed with an industrial x-ray cone beam CT measuring system. Three test parts were used in the experiments: a high accuracy manufacturing multi-wave standard, a calibrated step cylinder and a calibrated production part. The results demonstrate the usefulness of the approach to gain knowledge on CT measuring processes and improve the quality of CT geometrical evaluations. Advantages and limitations of the approach are discussed. (paper)

  5. X-ray quality control using TLD-100

    International Nuclear Information System (INIS)

    Rojas S, D. A.; Garcia V, E.; Azorin N, J.; Gaona, E.

    2017-10-01

    The use of thermoluminescent dosimeters in the area of medical physics and especially in radiology is of great importance to guarantee the quality of a given study, for this reason the need to verify by means of measurements for quality control in X-rays using thermoluminescent dosimeters of LiF:Mg,Ti was raised. For this, measurements of air Kerma, beam efficiency (reproducibility and linearity) and determination of the hemi-reductive layer were carried out, where previously the dosimeters were used, the graphs of the linear equation were used to obtain the absorbed dose of each dosimeter and thus the results of the absorbed dose calculated analytically against the value estimated by an electronic dosimeter were compared; it was found that the values of the absorbed dose are quantities similar to those stipulated by the electronic dosimeter. These measurements made it possible to verify the quality of the equipment that was used in the comparison. (Author)

  6. Long-term stability of beam quality and output of conventional X-ray units

    OpenAIRE

    Fukuda, Atsushi; Matsubara, Kosuke; Miyati, Toshiaki

    2015-01-01

    Conventional diagnostic X-ray units are used for radiographic imaging in many countries. For obtaining entrance surface doses, a numerical dose determination method has been applied in Japan. Although this technique is effective, it has to account for errors, particularly fluctuations, due to the beam quality and output of X-ray tubes. As a part of our quality control procedures, we recorded the entrance surface air kerma, tube voltage, and half-value layer measurements made for four diagnost...

  7. Quality audits of the remote-controlled automatically-driven gamma ray afterloading equipment used in brachytherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Zackova, H.; Horakova, I.

    2001-01-01

    To reach safety and precise application of ionisation radiation to patients Atomic act declares, in its Article no. 7, requirements for medical exposure. There are also given -among others -the demands to i nstall the quality assurance programmes (QA) for medical actions and functions . Since 1997, when the act has been adopted, a set of five Recommendations of State Office for Nuclear Safety (SONS ) for radiotherapy has been prepared to instruct users how to prepare quality control system (i.e. system of tests required by of the regulation no.184/1997 Sb. -acceptance, status and constancy tests) for main types of sources used in radiotherapy for treatment of the patients. Among them also the Recommendation on QA in brachytherapy has been issued by SONS in 1998. National Radiation Protection Institute (NRPI) has been performing the regular in situ quality audits in which the chosen parameters (which could seriously influence the dose to the patients -i.e. absorbed dose, main geometrical and radiation parameters etc ) are independently checked by the NRPI experts. System of Quality Audits on the sources used in teletherapy has been introduced in 1997 and at present time they are smoothly carried out according the SONS's demands. This work describes the process of installing of the Quality Audit system on brachytherapy. The work described here forms the only part of the activities, which have been carrying out by the department of dosimetry gamma and X-rays of NRPI to support supervisions of SONS in the field of radiation protection in radiotherapy .Quality audits in brachytherapy will extend the possibilities of NRPI. The Methods NRPI 43-01.30 prepared by NRPI could be used as documentation for all types of test which are at present time required by Czech legislation for the remote-controlled automatically-driven gamma-ray afterloading equipment used in brachytherapy. (authors)

  8. A setup to perform X-ray irradiation tests on scintillating fibres for the SciFi project

    CERN Document Server

    Gavardi, Laura; Joram, Christian; Kristic, Robert

    2017-01-01

    An X-ray setup has been installed at CERN. The setup will serve for quality assurance purposes related to the acceptance of $11'000~ \\text{km}$ of scintillating plastic fibres for the SciFi detector of LHCb. The X-ray tube has a tungsten target and can be powered up to 60kV, 30mA. The setup is intended to monitor the relative radiation response of the different fibre batches. The dose rate absorbed by the fibre under test can be tuned, adjusting the settings of the X-ray tube and adding aluminium filters of different thicknesses. When operating the X-ray tube without filters at a high voltage of $40\\rm \\,kV$ and an anode current of $30\\rm \\,mA$, the dose rate is about $23\\rm \\,Gy/min$. The maximum dose of about $35\\rm \\,kGy$ expected in the SciFi Tracker can be thus reached in about $1\\rm \\,day$.

  9. [Quality assurance in human genetic testing].

    Science.gov (United States)

    Stuhrmann-Spangenberg, Manfred

    2015-02-01

    Advances in technical developments of genetic diagnostics for more than 50 years, as well as the fact that human genetic testing is usually performed only once in a lifetime, with additional impact for blood relatives, are determining the extraordinary importance of quality assurance in human genetic testing. Abidance of laws, directives, and guidelines plays a major role. This article aims to present the major laws, directives, and guidelines with respect to quality assurance of human genetic testing, paying careful attention to internal and external quality assurance. The information on quality assurance of human genetic testing was obtained through a web-based search of the web pages that are referred to in this article. Further information was retrieved from publications in the German Society of Human Genetics and through a PubMed-search using term quality + assurance + genetic + diagnostics. The most important laws, directives, and guidelines for quality assurance of human genetic testing are the gene diagnostics law (GenDG), the directive of the Federal Medical Council for quality control of clinical laboratory analysis (RiliBÄK), and the S2K guideline for human genetic diagnostics and counselling. In addition, voluntary accreditation under DIN EN ISO 15189:2013 offers a most recommended contribution towards quality assurance of human genetic testing. Legal restraints on quality assurance of human genetic testing as mentioned in § 5 GenDG are fulfilled once RiliBÄK requirements are followed.

  10. X ray spectra and qualities for use in diagnostic radiology and equipment calibration

    International Nuclear Information System (INIS)

    Souza, Karla Cristina de

    1996-12-01

    The goal of this work was the standardization of radiation qualities of diagnostic X ray equipment of the Assay Laboratory of the Institute for Radiation Protection and Dosimetry (IRD) of the National Commission of Nuclear Energy, Brazil. X ray spectra were determined from pulse height distribution measured directly on the primary beam using a high pure planar Ge detector. A program was developed to convert pulse height distribution into radiation spectra in the range from 20 to 150 keV. X ray qualities based on those used by the 'Physikalish-Technish Bundesantalt' (PTB) primary laboratory were implanted in three radiological equipment of the Assay Laboratory. These qualities simulate radiation beams on patients submitted to typical radiological examinations. Besides the spectrometric system, a reference measurement system based on an ionization chamber calibrated in air kerma was used to establish parameters such as kilovoltage, first and second half-value layer, mean energy, effective energy and inherent filtration. Our data have shown that the implantation of these radiation qualities in the Assay Laboratory results on a metrological basis for calibration of dose measurement assemblies and kV-meters, like those used by IRD to evaluate the parameters of X ray equipment around the country. A catalogue of spectral data resulting from this work is a data bank that allows various applications like dose calculation using Monte Carlo simulation techniques. (author)

  11. Recent developments in detectors/phantoms for dosimetry, X-ray quality assurance and imaging

    International Nuclear Information System (INIS)

    Sankaran, A.

    2009-01-01

    During the past years, many new developments have taken place in detectors/phantoms for high energy photon and electron dosimetry (for radiotherapy), protection monitoring, X-ray quality assurance and X-ray imaging (for radiodiagnosis). A variety of detectors and systems, quality assurance (QA) gadgets and special phantoms have been developed for diverse applications. This paper discusses the important developments with some of which the author was actively associated in the past. For dosimetry and QA of 60 Co and high energy X-ray units, state-of-the-art radiation field analyzers, matrix ion chambers, MOSFET devices and Gafchromic films are described. OSL detectors find wide use in radiotherapy dosimetry and provide a good alternative for personnel monitoring. New systems introduced for QA/dosimetry of X-ray units and CT scanners include: multi-function instruments for simultaneous measurement of kVp, dose, time, X-ray waveform and HVT on diagnostic X-ray units; pencil chamber with head and body phantoms for CTDI check on CT scanners. Examples of phantoms used for dosimetry and imaging are given. Advancements in the field of diagnostic X-ray imaging (with applications in portal imaging/dosimetry of megavoltage X-ray units) have led to emergence of: film-replacement systems employing CCD-scintillator arrays, computed radiography (CR) using storage phosphor plate; digital radiography (DR), using a pixel-matrix of amorphous selenium, or amorphous silicon diode coupled to scintillator. All these provide (a) in radiotherapy, accurate dose delivery to tumour, saving the surrounding tissues and (b) in radiodiagnosis, superior image quality with low patient exposure. Lastly, iPODs and flash drives are utilized for storage of gigabyte-size images encountered in medical and allied fields. Although oriented towards medical applications, some of these have been of great utility in other fields, such as industrial radiography as well as a host of other research areas. (author)

  12. Ronchi test for characterization of nanofocusing optics at a hard x-ray free-electron laser.

    Science.gov (United States)

    Nilsson, Daniel; Uhlén, Fredrik; Holmberg, Anders; Hertz, Hans M; Schropp, Andreas; Patommel, Jens; Hoppe, Robert; Seiboth, Frank; Meier, Vivienne; Schroer, Christian G; Galtier, Eric; Nagler, Bob; Lee, Hae Ja; Vogt, Ulrich

    2012-12-15

    We demonstrate the use of the classical Ronchi test to characterize aberrations in focusing optics at a hard x-ray free-electron laser. A grating is placed close to the focus and the interference between the different orders after the grating is observed in the far field. Any aberrations in the beam or the optics will distort the interference fringes. The method is simple to implement and can provide single-shot information about the focusing quality. We used the Ronchi test to measure the aberrations in a nanofocusing Fresnel zone plate at the Linac Coherent Light Source at 8.194 keV.

  13. EOL3 M0 X-ray Tomography Test Results

    CERN Document Server

    Avramidou, R; Bozhko, N; Borisov, A; Goriatchev, V; Goriatchev, S; Gushin, V; Fakhroutdinov, R; Kojine, A; Kononov, A; Larionov, A; Salomatin, Yu I; Schuh, S; Sedykh, Yu; Tchougouev, A

    2001-01-01

    Results of X-ray tomography test of EOL3 module 0 chamber is presented in the note. Peculiarities of the X-ray tomography of the chamber are discussed. Comparison of the tomography results with predictions of the production site measurements is made.

  14. HPHT growth and x-ray characterization of high-quality type IIa diamond.

    Science.gov (United States)

    Burns, R C; Chumakov, A I; Connell, S H; Dube, D; Godfried, H P; Hansen, J O; Härtwig, J; Hoszowska, J; Masiello, F; Mkhonza, L; Rebak, M; Rommevaux, A; Setshedi, R; Van Vaerenbergh, P

    2009-09-09

    The trend in synchrotron radiation (x-rays) is towards higher brilliance. This may lead to a very high power density, of the order of hundreds of watts per square millimetre at the x-ray optical elements. These elements are, typically, windows, polarizers, filters and monochromators. The preferred material for Bragg diffracting optical elements at present is silicon, which can be grown to a very high crystal perfection and workable size as well as rather easily processed to the required surface quality. This allows x-ray optical elements to be built with a sufficient degree of lattice perfection and crystal processing that they may preserve transversal coherence in the x-ray beam. This is important for the new techniques which include phase-sensitive imaging experiments like holo-tomography, x-ray photon correlation spectroscopy, coherent diffraction imaging and nanofocusing. Diamond has a lower absorption coefficient than silicon, a better thermal conductivity and lower thermal expansion coefficient which would make it the preferred material if the crystal perfection (bulk and surface) could be improved. Synthetic HPHT-grown (high pressure, high temperature) type Ib material can readily be produced in the necessary sizes of 4-8 mm square and with a nitrogen content of typically a few hundred parts per million. This material has applications in the less demanding roles such as phase plates: however, in a coherence-preserving beamline, where all elements must be of the same high quality, its quality is far from sufficient. Advances in HPHT synthesis methods have allowed the growth of type IIa diamond crystals of the same size as type Ib, but with substantially lower nitrogen content. Characterization of this high purity type IIa material has been carried out with the result that the crystalline (bulk) perfection of some of the HPHT-grown materials is approaching the quality required for the more demanding applications such as imaging applications and imaging

  15. X-Ray Microtomography (μCT as a Useful Tool for Visualization and Interpretation of Shear Strength Test Results

    Directory of Open Access Journals (Sweden)

    Stefaniuk Damian

    2015-02-01

    Full Text Available The paper demonstrates the applicability of X-ray microtomography (ìCT to analysis of the results of shear strength examinations of clayey soils. The method of X-ray three-dimensional imaging offers new possibilities in soil testing. The work focuses on a non-destructive method of evaluation of specimen quality used in shear tests and mechanical behavior of soil. The paper presents the results of examination of 4 selected clayey soils. Specimens prepared for the triaxial test have been scanned using ìCT before and after the triaxial compression tests. The shear strength parameters of the soils have been estimated. Changes in soil structure caused by compression and shear failure have been presented as visualizations of the samples tested. This allowed for improved interpretation and evaluation of soil strength parameters and recognition of pre-existing fissures and the exact mode of failure. Basic geometrical parameters have been determined for selected cross-sections of specimens after failure. The test results indicate the utility of the method applied in soil testing.

  16. Safety assessment and quality control of medical x-ray facilities in some hospitals in Ghana

    International Nuclear Information System (INIS)

    Darko, E.O.; Charles, D.F.

    1998-01-01

    Safety assessment and quality control measurements of diagnostic x-ray installations were carried out in five hospitals in Ghana. The study was focused on the siting, design and construction of the buildings housing the x-ray units, assessment of safety systems and devices and measurements of the technical performance, and film processing conditions. The location, inadequacies in the design/construction, unavailability of relevant safety systems and devices, violation of basic safety principles and poor performance of some of the x-ray facilities indicate the need to improve quality control programmes, safety culture and enforcement of regulatory standards in diagnostic x-ray examinations in Ghana. (author). 8 refs., 11 tabs., 8 figs

  17. Automatic analysis of quality of images from X-ray digital flat detectors

    International Nuclear Information System (INIS)

    Le Meur, Y.

    2009-04-01

    Since last decade, medical imaging has grown up with the development of new digital imaging techniques. In the field of X-ray radiography, new detectors replace progressively older techniques, based on film or x-ray intensifiers. These digital detectors offer a higher sensibility and reduced overall dimensions. This work has been prepared with Trixell, the world leading company in flat detectors for medical radiography. It deals with quality control on digital images stemming from these detectors. High quality standards of medical imaging impose a close analysis of the defects that can appear on the images. This work describes a complete process for quality analysis of such images. A particular focus is given on the detection task of the defects, thanks to methods well adapted to our context of spatially correlated defects in noise background. (author)

  18. Current aspects in the development of the quality control in the conventional X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Velkova, K.

    2004-01-01

    The role of the X-ray diagnostic radiology as one of the main factors forming the general public dose is indisputable. Following the requirement for justification of the application of X-rays for medical purposes, certain criteria for assessment of the parameters of the X-ray diagnostic equipment are formed and maximum permissible values defined. The latter are developed by the international and national radiation protection organizations and introduced both in the international and national legislation. The importance of the quality assurance concept for the radiation protection of the patient and staff in diagnostic radiology turned the quality control into main toll for obtaining high quality images with minimum dose to the patient and staff. X-ray diagnostics is one of the most common methods used in the medical practice. This is the main reason for the increase of the quality control protocols, winch makes their handling difficult. The latest developments in this area bring forward the idea for the development of specialized quality control software, which is capable of: 1) full or semi-automated calculation and assessment of the parameters of the X-ray diagnostic units; 2) tools for data handling and access; 3) tools for data analysis based on predefined procedures

  19. Automatic weld joint X-ray inspection

    International Nuclear Information System (INIS)

    Richter, H.U.; Linke, D.; Siems, K.D.; Kruse, H.; Schuetze, E.

    1990-01-01

    A gantry mounted robotic x-ray inspection unit has been developed for the series testing of small and medium sized welded components (pipe bends and nozzles). The unit features computer controlled positioning of the x-ray tube and x-ray image amplifier. Image quality classes 2 and even 1 could be achieved without difficulty. (author)

  20. NIRO: a database of all X-ray units in use in Lower Saxony to improve radiation protection and quality control

    International Nuclear Information System (INIS)

    Brueggemeyer, H.; Siewert, T.

    1995-01-01

    The paper gives an overview on the structure and intention of a database on all X ray units in Lower Saxony. For every X ray unit tested some technical and administrative data were sent to the database. All institutions and authorities in Lower Saxony related to X ray safety are connected to the database. As all X ray units are re-inspected every 5 years this data is used to update the data. This database is a tool to identify and supervise all x ray units, to find all units of a special type in case of defect clusters, for statistical purposes and for administration demands. Some examples for possible statistical evaluations are given. This database has become a very important and helpful tool to secure a good and complete performance of radiation protection and quality control throughout Lower Saxony. (Author)

  1. First results of the cosmic rays test of the RPC of the ATLAS muon spectrometer at LHC

    CERN Document Server

    Alviggi, M G; Caprio, M A; Carlino, G; De Asmundis, R; Della Pietra, M; Della Volpe, D; Iengo, P; Patricelli, S; Sekhniaidze, G

    2004-01-01

    The trigger for the Barrel Muon Spectrometer of the ATLAS experiment at LHC will be given by means of Resistive Plate Chambers working in avalanche mode. Before being mounted on the experimental apparatus each RPC chamber will undergo detailed quality control tests. A dedicated cosmic rays test station with good tracking resolution is operational in Naples University and INFN laboratory. All working parameters of RPCs are monitored and measured. Moreover, the uniformity of the efficiency on the whole surface is measured. A brief description of the test station and results for the first 148 Units will be presented.

  2. The Ferrara hard X-ray facility for testing/calibrating hard X-ray focusing telescopes

    Science.gov (United States)

    Loffredo, Gianluca; Frontera, Filippo; Pellicciotta, Damiano; Pisa, Alessandro; Carassiti, Vito; Chiozzi, Stefano; Evangelisti, Federico; Landi, Luca; Melchiorri, Michele; Squerzanti, Stefano

    2005-12-01

    We will report on the current configuration of the X-ray facility of the University of Ferrara recently used to perform reflectivity tests of mosaic crystals and to calibrate the experiment JEM X aboard Integral. The facility is now located in the technological campus of the University of Ferrara in a new building (named LARIX laboratory= LARge Italian X-ray facility) that includes a tunnel 100 m long with, on the sides, two large experimental rooms. The facility is being improved for determining the optical axis of mosaic crystals in Laue configuration, for calibrating Laue lenses and hard X-ray mirror prototypes.

  3. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  4. Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India.

    Science.gov (United States)

    Sonawane, A U; Singh, Meghraj; Sunil Kumar, J V K; Kulkarni, Arti; Shirva, V K; Pradhan, A S

    2010-10-01

    We conducted a radiological safety and quality assurance (QA) audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements stipulated by the national regulatory body. The audit mainly covered accuracy check of accelerating potential (kVp), linearity of tube current (mA station) and timer, congruence of radiation and optical field, and total filtration; in addition, we also reviewed medical X-ray diagnostic installations with reference to room layout of X-ray machines and conduct of radiological protection survey. A QA kit consisting of a kVp Test-O-Meter (ToM) (Model RAD/FLU-9001), dose Test-O-Meter (ToM) (Model 6001), ionization chamber-based radiation survey meter model Gun Monitor and other standard accessories were used for the required measurements. The important areas where there was noncompliance with the national safety code were: inaccuracy of kVp calibration (23%), lack of congruence of radiation and optical field (23%), nonlinearity of mA station (16%) and timer (9%), improper collimator/diaphragm (19.6%), faulty adjustor knob for alignment of field size (4%), nonavailability of warning light (red light) at the entrance of the X-ray room (29%), and use of mobile protective barriers without lead glass viewing window (14%). The present study on the radiological safety status of diagnostic X-ray installations may be a reasonably good representation of the situation in the country as a whole. The study contributes significantly to the improvement of radiological safety by the way of the steps already taken and by providing a vital feed back to the national regulatory body.

  5. Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India

    International Nuclear Information System (INIS)

    Sonawane, A.U.; Singh, Meghraj; Sunil Kumar, J.V.K.; Kulkarni, Arti; Shirva, V.K.; Pradhan, A.S.

    2010-01-01

    We conducted a radiological safety and quality assurance (QA) audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements stipulated by the national regulatory body. The audit mainly covered accuracy check of accelerating potential (kVp), linearity of tube current (mA station) and timer, congruence of radiation and optical field, and total filtration; in addition, we also reviewed medical X-ray diagnostic installations with reference to room layout of X-ray machines and conduct of radiological protection survey. A QA kit consisting of a kVp Test-O-Meter (ToM) (Model RAD/FLU-9001), dose Test-O-Meter (ToM) (Model 6001), ionization chamber-based radiation survey meter model Gun Monitor and other standard accessories were used for the required measurements. The important areas where there was noncompliance with the national safety code were: inaccuracy of kVp calibration (23%), lack of congruence of radiation and optical field (23%), nonlinearity of mA station (16%) and timer (9%), improper collimator/diaphragm (19.6%), faulty adjustor knob for alignment of field size (4%), nonavailability of warning light (red light) at the entrance of the X-ray room (29%), and use of mobile protective barriers without lead glass viewing window (14%). The present study on the radiological safety status of diagnostic X-ray installations may be a reasonably good representation of the situation in the country as a whole. The study contributes significantly to the improvement of radiological safety by the way of the steps already taken and by providing a vital feed back to the national regulatory body. (author)

  6. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  7. The research on x-ray nondestructive testing and image processing technology of explosive components

    International Nuclear Information System (INIS)

    Shi, C.; Zhai, X.; Liu, Z.; Lin, H.

    2004-01-01

    The explosive components will inevitably produce defects such as impurity, crack and degumming during production and storage, therefore the inside substance of the explosive components must be examined and the findings concerned must be identified and estimated in order to ensure the quality and service life of the explosive components. Firstly, some analyses are conducted on the usual X-ray NDT system theory, and the simulation explosive component is made with some pre-built defects such as debonding, cracks, blow holes, impurities, and non-uniform density. The image testing system most fit for the explosive components is established. Secondly, the ways of X-ray digital image processing are discussed; the obtained images are enhanced and restored through the self-accommodating build-up arithmetic and proper restoring methods. By means of the results of the overall comparison and analysis of the digital image processing technology, it is clearly indicated that it is feasible to use X-ray digital-imaging ways to carry out the NDT of explosive components and identify the inside defects. (author)

  8. Software quality testing process analysis

    OpenAIRE

    Mera Paz, Julián

    2016-01-01

    Introduction: This article is the result of reading, review, analysis of books, magazines and articles well known for their scientific and research quality, which have addressed the software quality testing process. The author, based on his work experience in software development companies, teaching and other areas, has compiled and selected information to argue and substantiate the importance of the software quality testing process. Methodology: the existing literature on the software qualit...

  9. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment

    International Nuclear Information System (INIS)

    Costa, A.M.; Caldas, L.V.E.

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy responses of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities. (author)

  10. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    Science.gov (United States)

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  11. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  12. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    International Nuclear Information System (INIS)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  13. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  14. Low-Energy Microfocus X-Ray Source for Enhanced Testing Capability in the Stray Light Facility

    Science.gov (United States)

    Gaskin, Jessica; O'Dell, Stephen; Kolodziejczak, Jeff

    2015-01-01

    Research toward high-resolution, soft x-ray optics (mirrors and gratings) necessary for the next generation large x-ray observatories requires x-ray testing using a low-energy x-ray source with fine angular size (energy microfocus (approximately 0.1 mm spot) x-ray source from TruFocus Corporation that mates directly to the Stray Light Facility (SLF). MSFC X-ray Astronomy team members are internationally recognized for their expertise in the development, fabrication, and testing of grazing-incidence optics for x-ray telescopes. One of the key MSFC facilities for testing novel x-ray instrumentation is the SLF. This facility is an approximately 100-m-long beam line equipped with multiple x-ray sources and detectors. This new source adds to the already robust compliment of instrumentation, allowing MSFC to support additional internal and community x-ray testing needs.

  15. Radiation safety and quality in diagnostic x-ray imaging 2001; Saeteilyturvallisuus ja laatu roentgendiagnostiikassa 2001

    Energy Technology Data Exchange (ETDEWEB)

    Servomaa, A.; Parviainen, T. (eds.)

    2001-05-01

    The obligations of the medical exposure directive (97/43/Euratom) for hospitals dominate the current activities in radiation protection in medical radiology. The directive gives special emphasis to radiation exposure of children, to examinations with high radiation doses and to radiation exposure in health screening programmes. The most important examinations with high doses are radiological interventions, where even acute skin effects are possible, and the computed tomography where the number of CT examinations makes only about 5% from the total number of x-ray examinations but the collective effective dose about 40% from the combined collective effective dose of all x-ray examinations. In the research projects financed by the European Commission, radiation exposures to paediatric patients have been measured in radiography, fluoroscopy and CT, and various dose assessment methods have been compared to develop a method for national follow-up of patients' radiation dose. The newest research project is focused on dosimetry and quality assurance in interventional radiology and digital imaging. Other actual topics are the development of radiation protection regulations and quality systems, education and training programmes, and clinical audits. This report deals with new radiation protection guides and recommendations and the education and training of radiological staff in radiation protection. One important topic is the development of national follow-up method of radiation exposure to patients and comparison of various dose assessment methods. Quality assurance in health care and in paediatric radiology, and the acceptance test and quality assurance measurements of radiological equipment are also described. (orig.)

  16. Quality assurance of measurement of X-ray system/ YXLON-MG325 for calibration of radiation measuring instrument

    International Nuclear Information System (INIS)

    Nazaroh; Assef Firnando Firmansyah; Gatot Wurdiyanto; Nurman Rajagukguk

    2016-01-01

    Quality assurance of measurements is all of the planned activities and systematic measurements, which is needed to provide adequate confidence that a product / service will meet the quality requirements specified. The objective of measurement quality assurance is to ensure that results of measurement was adequate (traceable and accurate), so that the entire measurement process, components and relevant factors that influence should be considered, monitored and controlled. X-ray /YXLON- MG325 is an X-ray that has a bipolar potential with power 4.5 kW and a maximum tube voltage of 325 kV so as to have the energy and the dose rate that is high enough for various purposes such as radiography, radioscopy, scanning tomography and for calibration / test. To ensure the quality measurements on the X-ray / YXLON-MG325, it has been carried out beam homogeneity measurement using an Ionization Chamber detector (IC) 0.016 cm"3 coupled with Unidose PTW electrometer and the beam was homogeneous, in the range of ±8.75 cm. Besides that, the linearity determination was done using an IC detector 2575C / #576, volume 600 CC coupled with Unidose PTW electrometer, and the result was linear, with correlation coefficient, r was 1. Determination of the first and second HVL in the energy range of (60-200) kV, using an IC detector volume 600 CC coupled with a Keithley electrometer, and the result was: First HVL, Y = 0.0274x - 1.5435, r = 0.996, Second HVL, Y = 0.056x - 3.1375, r = 0.996.In this paper was presented output measurement of X-ray/YXLON-MG325 at N (80), I = 20 mA, FOC = 5.5 mm, in term of air Kerma rate, Ka, was (335.1 ± 3.9%) μGy/minutes, and in term of personal dose equivalent, Hp (10) was (630 ± 4%) μSv/minutes. (author)

  17. Radiation safety and quality control assurance in X-ray diagnostics 1998; Saeteilyturvallisuus ja laadunvarmistus roentgendiagnostiikassa 1998

    Energy Technology Data Exchange (ETDEWEB)

    Servomaa, A [ed.

    1998-03-01

    The report is based on a seminar course of lectures `Radiation safety and quality assurance in X-ray diagnostics 1998` organized by the Radiation and Nuclear Safety Authority (STUK) in Finland. The lectures included actual information on X-ray examinations: methods of quality assurance, methods of measuring and calculating patient doses, examination frequencies, patient doses, occupational doses, and radiation risks. Paediatric X-ray examinations and interventional procedures were the most specific topics. The new Council Directive 97/43/Euratom on medical exposure, and the European Guidelines on quality criteria for diagnostic radiographic images, were discussed in several lectures. Lectures on general radiation threats and preparedness, examples of radiation accidents, and emergency preparedness in hospitals were also included. (editor)

  18. Testing of x-ray microtomography systems using a traceable geometrical standard

    International Nuclear Information System (INIS)

    Carmignato, S; Dreossi, D; Mancini, L; Tromba, G; Marinello, F; Savio, E

    2009-01-01

    X-ray computed microtomography is an interesting imaging technique for many applications, and is also very promising in the field of coordinate metrology at the micro scale. The main advantage with respect to traditional tactile-probing or optical coordinate measurement systems is that x-ray tomography can acquire dimensional and geometrical data for both inner and outer surfaces, without accessibility restrictions. However, there are no accepted test procedures available so far and measurement uncertainty is unknown in many cases, due to complex and numerous error sources. The paper presents the first results of a test procedure implemented for determining the errors of indication for length measurements of x-ray microtomography systems, using a new reference standard featuring a regular array of inner and outer cylindrical shapes. The developed test method allows the determination of specific characteristics of x-ray microtomography systems and can be used for the correction of systematic errors

  19. NASA X-Ray Observatory Completes Tests Under Harsh Simulated Space Conditions

    Science.gov (United States)

    1998-07-01

    NASA's most powerful X-ray observatory has successfully completed a month-long series of tests in the extreme heat, cold, and airless conditions it will encounter in space during its five-year mission to shed new light on some of the darkest mysteries of the universe. The Advanced X-ray Astrophysics Facility was put through the rigorous testing as it was alternately heated and cooled in a special vacuum chamber at TRW Space and Electronics Group in Redondo Beach, Calif., NASA's prime contractor for the observatory. "Successful completion of thermal vacuum testing marks a significant step in readying the observatory for launch aboard the Space Shuttle in January," said Fred Wojtalik, manager of the Observatory Projects Office at NASA's Marshall Space Flight Center in Huntsville, Ala. "The observatory is a complex, highly sophisticated, precision instrument," explained Wojtalik. "We are pleased with the outcome of the testing, and are very proud of the tremendous team of NASA and contractor technicians, engineers and scientists that came together and worked hard to meet this challenging task." Testing began in May after the observatory was raised into the 60-foot thermal vacuum chamber at TRW. Testing was completed on June 20. During the tests the Advanced X-ray Astrophysics Facility was exposed to 232 degree heat and 195 degree below zero Fahrenheit cold. During four temperature cycles, all elements of the observatory - the spacecraft, telescope, and science instruments - were checked out. Computer commands directing the observatory to perform certain functions were sent from test consoles at TRW to all Advanced X-ray Astrophysics Facility components. A team of contractor and NASA engineers and scientists monitored and evaluated the results. Commands were also sent from, and test data monitored at, the Advanced X-ray Astrophysics Facility Operations Control Center in Cambridge, Mass., as part of the test series. The observatory will be managed and controlled from

  20. Effect of gamma-ray on olive fruits quality, enzyme activities and issued oil

    International Nuclear Information System (INIS)

    Mejri, Sonia

    2007-01-01

    The results described in the present work concern the study of changes in gamma ray irradiated olive fruit (Tunisian variety: C hemlali ) quality along the storage time processing and the quality of olive oil issued. The study focused on the changes related to the microbiological, physico-chemical properties, as well as pectinase activities in olive after irradiation. We also have been interested in the final product quality after oil extraction. The results of non irradiated olives were presented for comparative purposes. Mature olive fruits were treated with 0.5, 1 and 1.5 kGy gamma ray radiation. Olive fruits were then stored for one month. Irradiation at 1.5 kGy allows the almost total destruction of the total aerobic germs, yeasts and moulds. Concerning physico-chemical parameters, the increase of the dose level generated an improvement in water retention capacity and decreased the rate of polysaccharides hydrolyzes olives. Moreover, the irradiation dose of 0.5 kGy induced the increase in pectinase activities thanks to the improvement of the protein extraction yield. The gamma ray irradiation of olive fruit seems to not decrease olive oil oxidative stability in the studied samples. Finally, gamma ray radiation was able to improve the yield of extraction of the oil and insaponifiable fraction as polyphenols and beta carotenes. (Author)

  1. Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India

    Directory of Open Access Journals (Sweden)

    Sonawane A

    2010-01-01

    Full Text Available We conducted a radiological safety and quality assurance (QA audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements stipulated by the national regulatory body. The audit mainly covered accuracy check of accelerating potential (kVp, linearity of tube current (mA station and timer, congruence of radiation and optical field, and total filtration; in addition, we also reviewed medical X-ray diagnostic installations with reference to room layout of X-ray machines and conduct of radiological protection survey. A QA kit consisting of a kVp Test-O-Meter (ToM (Model RAD/FLU-9001, dose Test-O-Meter (ToM (Model 6001, ionization chamber-based radiation survey meter model Gun Monitor and other standard accessories were used for the required measurements. The important areas where there was noncompliance with the national safety code were: inaccuracy of kVp calibration (23%, lack of congruence of radiation and optical field (23%, nonlinearity of mA station (16% and timer (9%, improper collimator/diaphragm (19.6%, faulty adjustor knob for alignment of field size (4%, nonavailability of warning light (red light at the entrance of the X-ray room (29%, and use of mobile protective barriers without lead glass viewing window (14%. The present study on the radiological safety status of diagnostic X-ray installations may be a reasonably good representation of the situation in the country as a whole. The study contributes significantly to the improvement of radiological safety by the way of the steps already taken and by providing a vital feed back to the national regulatory body.

  2. Application of newly developed Fluoro-QC software for image quality evaluation in cardiac X-ray systems.

    Science.gov (United States)

    Oliveira, M; Lopez, G; Geambastiani, P; Ubeda, C

    2018-05-01

    A quality assurance (QA) program is a valuable tool for the continuous production of optimal quality images. The aim of this paper is to assess a newly developed automatic computer software for image quality (IR) evaluation in fluoroscopy X-ray systems. Test object images were acquired using one fluoroscopy system, Siemens Axiom Artis model (Siemens AG, Medical Solutions Erlangen, Germany). The software was developed as an ImageJ plugin. Two image quality parameters were assessed: high-contrast spatial resolution (HCSR) and signal-to-noise ratio (SNR). The time between manual and automatic image quality assessment procedures were compared. The paired t-test was used to assess the data. p Values of less than 0.05 were considered significant. The Fluoro-QC software generated faster IQ evaluation results (mean = 0.31 ± 0.08 min) than manual procedure (mean = 4.68 ± 0.09 min). The mean difference between techniques was 4.36 min. Discrepancies were identified in the region of interest (ROI) areas drawn manually with evidence of user dependence. The new software presented the results of two tests (HCSR = 3.06, SNR = 5.17) and also collected information from the DICOM header. Significant differences were not identified between manual and automatic measures of SNR (p value = 0.22) and HCRS (p value = 0.46). The Fluoro-QC software is a feasible, fast and free to use method for evaluating imaging quality parameters on fluoroscopy systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  4. Bureau of radiological health compliance testing procedures for cabinet S-ray systems

    International Nuclear Information System (INIS)

    Miller, E.A.; Sprau, D.

    1976-01-01

    A manual has been developed by the Bureau of Radiological Health of the Food and Drug Administration to establish procedures for the routine field testing of cabinet x-ray systems to determine compliance with the Federal Performance Standard for Cabinet X-Ray Systems, 21 CFR 1020.40. The manual provides specific instructions for testing each model of cabinet x-ray system. Results from the inspection are recorded on a data from which is designed to permit automatic data processing

  5. Field testing for cosmic ray soft errors in semiconductor memories

    International Nuclear Information System (INIS)

    O'Gorman, T.J.; Ross, J.M.; Taber, A.H.; Ziegler, J.F.; Muhlfeld, H.P.; Montrose, C.J.; Curtis, H.W.; Walsh, J.L.

    1996-01-01

    This paper presents a review of experiments performed by IBM to investigate the causes of soft errors in semiconductor memory chips under field test conditions. The effects of alpha-particles and cosmic rays are separated by comparing multiple measurements of the soft-error rate (SER) of samples of memory chips deep underground and at various altitudes above the earth. The results of case studies on four different memory chips show that cosmic rays are an important source of the ionizing radiation that causes soft errors. The results of field testing are used to confirm the accuracy of the modeling and the accelerated testing of chips

  6. A distribution-free test for anomalous gamma-ray spectra

    International Nuclear Information System (INIS)

    Chan, Kung-sik; Li, Jinzheng; Eichinger, William; Bai, Er-Wei

    2014-01-01

    Gamma-ray spectra are increasingly acquired in monitoring cross-border traffic, or in an area search for lost or orphan special nuclear material (SNM). The signal in such data is generally weak, resulting in poorly resolved spectra, thereby making it hard to detect the presence of SNM. We develop a new test for detecting anomalous spectra by characterizing the complete shape change in a spectrum from background radiation; the proposed method may serve as a tripwire for routine screening for SNM. We show that, with increasing detection time, the limiting distribution of the test is given by some functional of the Brownian bridge. The efficacy of the proposed method is illustrated by simulations. - Highlights: • We develop a new non-parametric test for detecting anomalous gamma-ray spectra. • The proposed test has good empirical power for detecting weak signals. • It can serve as an effective tripwire for invoking more thorough scrutiny of the source

  7. X-ray Spectroscopy for Quality Control of Chemotherapy Drugs

    International Nuclear Information System (INIS)

    Greaves, E. D.; Barros, H.; Bermudez, J.; Sajo-Bohus, L.; Angeli-Greaves, M.

    2007-01-01

    We develop a method, employing Compton peak standardization and the use of matrix-matched spiked samples with Total Reflection X-ray Fluorescence (TXRF), for the determination of platinum plasma concentrations of patients undergoing chemotherapy with Pt-bearing drugs. Direct blood plasma analysis attains Pt detection limits of 70 ng/ml. Measurement results of prescribed drug doses are compared to achieved blood Pt concentrations indicating a lack of expected correlations. Direct analysis of Pt-containing infused drugs from a variety of suppliers indicates cases of abnormal concentrations which raises quality control issues. We demonstrate the potential usefulness of the method for pharmacokinetic studies or for routine optimization and quality control of Pt chemotherapy treatments

  8. Analytical quality control of neutron activation analysis by interlaboratory comparison and proficiency test

    International Nuclear Information System (INIS)

    Kim, S. H.; Moon, J. H.; Jeong, Y. S.

    2002-01-01

    Two air filters (V-50, P-50) artificially loaded with urban dust were provided from IAEA and trace elements to study inter-laboratory comparison and proficiency test were determined using instrumental neutron activation analysis non-destructively. Standard reference material(Urban Particulate Matter, NIST SRM 1648) of National Institute of Standard and Technology was used for internal analytical quality control. About 20 elements in each loaded filter sample were determined, respectively. Our analytical data were compared with statistical results using neutron activation analysis, particle induced X-ray emission spectrometry, inductively coupled plasma mass spectroscopy, etc., which were collected from 49 laboratories of 40 countries. From the results that were statistically re-treated with reported values, Z-scores of our analytical values are within ±2. In addition, the results of proficiency test are passed and accuracy and precision of the analytical values are reliable. Consequently, it was proved that analytical quality control for the analysis of air dust samples is reasonable

  9. The quality of high-energy X-ray beams

    International Nuclear Information System (INIS)

    LaRiviere, P.D.

    1989-01-01

    Supplement 17 of the British Journal of Radiology is a survey of central-axis depth doses for radiotherapy machines, patterned largely on BJR Supplement 11 (1972). Inspection of high-energy X-ray depth doses for a 10 x 10 cm field at an SSD of 100 cm disclosed large differences between the two sets of data, especially for qualities above 8 MV, e.g. a depth dose of 80% at 10 cm is rated at about 19 MV according to BJR Supplement 11, and 23 MV according to BJR Supplement 17. It was found that Supplement 17 depth-dose data above 8 MV were erratic, but Supplement 11 data could be represented by an analytical expression, providing a unique means of assigning MV quality. It was also found that dose-weighted average energy of the filtered beam plotted smoothly against depth dose. For dosimetric purposes, it is suggested that this parameter be used as a true measure of beam quality, removing discrepancies introduced by the use of nominal MV for this purpose. (author)

  10. Precision scan-imaging for paperboard quality inspection utilizing X-ray fluorescence

    Science.gov (United States)

    Norlin, B.; Reza, S.; Fröjdh, C.; Nordin, T.

    2018-01-01

    Paperboard is typically made up of a core of cellulose fibers [C6H10O5] and a coating layer of [CaCO3]. The uniformity of these layers is a critical parameter for the printing quality. Current quality control methods include chemistry based visual inspection methods as well as X-ray based methods to measure the coating thickness. In this work we combine the X-ray fluorescence signals from the Ca atoms (3.7 keV) in the coating and from a Cu target (8.0 keV) placed behind the paper to simultaneously measure both the coating and the fibers. Cu was selected as the target material since its fluorescence signal is well separated from the Ca signal while its fluorescence's still are absorbed sufficiently in the paper. A laboratory scale setup is built using stepper motors, a silicon drift detector based spectrometer and a collimated X-ray beam. The spectroscopic image is retrieved by scanning the paperboard surface and registering the fluorescence signals from Ca and Cu. The exposure time for this type of setups can be significantly improved by implementing spectroscopic imaging sensors. The material contents in the layers can then be retrieved from the absolute and relative intensities of these two signals.

  11. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  12. Image quality analysis of vibration effects In C-arm-flat panel X-ray imaging

    NARCIS (Netherlands)

    Snoeren, R.M.; Kroon, J.N.; With, de P.H.N.

    2011-01-01

    The motion of C-arm scanning X-ray systems may result in vibrations of the imaging sub-system. In this paper, we connect C-arm system vibrations to Image Quality (IQ) deterioration for 2D angiography and 3D cone beam X-ray imaging, using large Flat Panel detectors. Vibrations will affect the

  13. Acceptance testing and quality assurance of Simulix evolution radiotherapy simulator

    International Nuclear Information System (INIS)

    Sinha, Ashutosh; Singh, Navin; Gurjar, Om Prakash; Bagdare, Priyusha

    2015-01-01

    The success of radiotherapy depends on precise treatment simulation and proper patient positioning. The simulator is a conventional radiographic and fluoroscopic system which emulates the geometrical positions of radiotherapy treatment unit. Hence, the acceptance tests and quality assurance (QA) of the simulator are important prior to its commissioning for the safe and precise clinical use. The verification of mechanical and optical readouts, field size, isocenter, optical and radiation field congruence were performed. The X-ray beam parameters were tested for kVp, mAs and consistency of radiation output. The flat panel detector performance was checked with respect to resolution, low contrast sensitivity (LCS), automatic dose rate control (ADRC), and gray image resolution (GIR). Gantry, table, and imaging system collision possibility was checked. Radiation survey around the room was also performed. The field size test for digital readout and on graph paper, the results of isocenter checkup for rotation of gantry, collimator, and couch, and the deviations observed in auto stop for various movements were found within the tolerance limits. Optical field and radiation field was found congruent. All the lasers were found aligned with the established isocenter. Maximum deviation for set and measured kV was found to be 3% in fluoro mode. The maximum deviation observed in mAs was 1.5% in 3-point as well as in 2-point film exposed mode. The X-ray output was found consistent. The results of tests for resolution, LCS, ADRC, and GIR of the flat panel detector were within tolerance limits. All the six safety interlocks were found working. Radiation level around the room was found within the acceptable limits. All the tests carried out were found within the tolerance limits. The data which has been taken in this study will provide basic support to the routine QA of the simulator. (author)

  14. Entrance surface dose and image quality: Comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia

    International Nuclear Information System (INIS)

    Hambali, A. S.; Ng, K. H.; Abdullah, B. J. J.; Wang, H. B.; Jamal, N.; Spelic, D. C.; Suleiman, O. H.

    2009-01-01

    This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia. (authors)

  15. Self-masking noise subtraction (SMNS) in digital X-ray tomosynthesis for the improvement of tomographic image quality

    International Nuclear Information System (INIS)

    Oh, J.E.; Cho, H.S.; Choi, S.I.; Park, Y.O.; Lee, M.S.; Cho, H.M.; Yang, Y.J.; Je, U.K.; Woo, T.H.; Lee, H.K.

    2011-01-01

    In this paper, we proposed a simple and effective reconstruction algorithm, the so-called self-masking noise subtraction (SMNS), in digital X-ray tomosynthesis to reduce the tomographic blur that is inherent in the conventional tomosynthesis based upon the shift-and-add (SAA) method. Using the SAA and the SMNS algorithms, we investigated the influence of tomographic parameters such as tomographic angle (θ) and angle step (Δθ) on the image quality, measuring the signal-difference-to-noise ratio (SDNR). Our simulation results show that the proposed algorithm seems to be efficient in reducing the tomographic blur and, thus, improving image sharpness. We expect the simulation results to be useful for the optimal design of a digital X-ray tomosynthesis system for our ongoing application of nondestructive testing (NDT).

  16. Seed viability of five wild Saudi Arabian species by germination and X-ray tests.

    Science.gov (United States)

    Al-Hammad, B A; Al-Ammari, B S

    2017-09-01

    Our objective was to evaluate the usefulness of the germination vs. the X-ray test in determining the initial viability of seeds of five wild species ( Moringa peregrina , Abrus precatorius , Arthrocnemum macrostachyum , Acacia ehrenbergiana and Acacia tortilis ) from Saudi Arabia. Usually several days were required to determine the viability of all five species via germination tests. However, X-ray test will give immediate results on filled/viable seeds. Seeds of all species, except Acacia ehrenbergiana and Acacia tortilis showed high viability in both germination (96-72% at 25/15 °C, 94-70% at 35/25 °C) and X-ray (100-80%) test. Furthermore, there was a general agreement between the germination (19%, 14% at 25/15 °C and 17% and 12% at 35/25 °C) and X-ray (8%, 4%) tests in which seed viability of Acacia ehrenbergiana and Acacia tortilis was very low due to insect damaged embryo as shown in X-ray analysis. Seeds of Abruspreca torius have physical dormancy, which was broken by scarification in concentrated sulfuric acid (10 min), and they exhibited high viability in both the germination (83% at 25/15 °C and 81% at 35/25 °C) and X-ray (96%) tests. Most of the nongerminated seeds of the five species except those of Acacia ehrenbergiana and Acacia tortilis , were alive as judged by the tetrazolium test (TZ). Thus, for the five species examined, the X-ray test was proved to be a good and rapid predictor of seed viability.

  17. Flying spin qualities testing of airplane

    Directory of Open Access Journals (Sweden)

    Kostić Čedomir J.

    2015-01-01

    Full Text Available In this paper is presented the theoretical analysis of origins and characteristics of spinning motion. There are precise explanation of every stage spin flight and basic meaning of notion. Personated equation of motion in spin and equitation of motion airplane in settled spin motion, analysis of them and general recommendation for pilots for recovering from spins. Introduced in valid military and civil specifications flight test demonstration requirements for departure resistance and flying stall and spin qualities testing of airplane. Special attention was given on predicting departure, stall and spin susceptibility and theoretical analysis in the name of magnify flight testing security. There are explanation of test equipment and methodology of flying qualities testing of airplanes. Like a support of this theme are described method and results of flight stall and spin qualities testing of airplane G-4(N-62 super see-gull with precise recommendation for pilots for recovering from spins, from TOC SLI VS (Technical testing center, department for fight testing Air Force of Serbia.

  18. TU-F-18C-03: X-Ray Scatter Correction in Breast CT: Advances and Patient Testing

    International Nuclear Information System (INIS)

    Ramamurthy, S; Sechopoulos, I

    2014-01-01

    Purpose: To further develop and perform patient testing of an x-ray scatter correction algorithm for dedicated breast computed tomography (BCT). Methods: A previously proposed algorithm for x-ray scatter signal reduction in BCT imaging was modified and tested with a phantom and on patients. A wireless electronic positioner system was designed and added to the BCT system that positions a tungsten plate in and out of the x-ray beam. The interpolation used by the algorithm was replaced with a radial basis function-based algorithm, with automated exclusion of non-valid sampled points due to patient motion or other factors. A 3D adaptive noise reduction filter was also introduced to reduce the impact of scatter quantum noise post-reconstruction. The impact on image quality of the improved algorithm was evaluated using a breast phantom and seven patient breasts, using quantitative metrics such signal difference (SD) and signal difference-to-noise ratios (SDNR) and qualitatively using image profiles. Results: The improvements in the algorithm resulted in a more robust interpolation step, with no introduction of image artifacts, especially at the imaged object boundaries, which was an issue in the previous implementation. Qualitative evaluation of the reconstructed slices and corresponding profiles show excellent homogeneity of both the background and the higher density features throughout the whole imaged object, as well as increased accuracy in the Hounsfield Units (HU) values of the tissues. Profiles also demonstrate substantial increase in both SD and SDNR between glandular and adipose regions compared to both the uncorrected and system-corrected images. Conclusion: The improved scatter correction algorithm can be reliably used during patient BCT acquisitions with no introduction of artifacts, resulting in substantial improvement in image quality. Its impact on actual clinical performance needs to be evaluated in the future. Research Agreement, Koning Corp., Hologic

  19. Impact of large x-ray beam collimation on image quality

    Science.gov (United States)

    Racine, Damien; Ba, Alexandre; Ott, Julien G.; Bochud, François O.; Verdun, Francis R.

    2016-03-01

    Large X-ray beam collimation in computed tomography (CT) opens the way to new image acquisition techniques and improves patient management for several clinical indications. The systems that offer large X-ray beam collimation enable, in particular, a whole region of interest to be investigated with an excellent temporal resolution. However, one of the potential drawbacks of this option might be a noticeable difference in image quality along the z-axis when compared with the standard helical acquisition mode using more restricted X-ray beam collimations. The aim of this project is to investigate the impact of the use of large X-ray beam collimation and new iterative reconstruction on noise properties, spatial resolution and low contrast detectability (LCD). An anthropomorphic phantom and a custom made phantom were scanned on a GE Revolution CT. The images were reconstructed respectively with ASIR-V at 0% and 50%. Noise power spectra, to evaluate the noise properties, and Target Transfer Functions, to evaluate the spatial resolution, were computed. Then, a Channelized Hotelling Observer with Gabor and Dense Difference of Gaussian channels was used to evaluate the LCD using the Percentage correct as a figure of merit. Noticeable differences of 3D noise power spectra and MTF have been recorded; however no significant difference appeared when dealing with the LCD criteria. As expected the use of iterative reconstruction, for a given CTDIvol level, allowed a significant gain in LCD in comparison to ASIR-V 0%. In addition, the outcomes of the NPS and TTF metrics led to results that would contradict the outcomes of CHO model observers if used for a NPWE model observer (Non- Prewhitening With Eye filter). The unit investigated provides major advantages for cardiac diagnosis without impairing the image quality level of standard chest or abdominal acquisitions.

  20. Constancy tests radiography X-ray devices with CR system

    International Nuclear Information System (INIS)

    Durdikova, M.; Zakova, M.

    2005-01-01

    The paper presents the changes in QAP (Quality Assurance Program) as consequence of digitalisation of medical facilities. Digitalisation brings many advantages - more comfort for personal use, images are easy achievable and transferable to workstation, fine quality images by postprocessing are easily achievable. But it must be taken into account that due to simplicity of image make it is sometimes taken more images then necessary .There are two possible ways of digitalisation in radiography: to exchange conventional developer machine by Computer Radiography (CR), that means to use CR reader and cassette with phosphor plate - un-direct digitalisation or to use special radiography X-ray devices with flat-panel detector -direct radiography. (authors)

  1. Digital computed radiography in industrial X-ray testing

    International Nuclear Information System (INIS)

    Osterloh, K.; Onel, Y.; Zscherpel, U.; Ewert, U.

    2001-01-01

    Computed radiography is used for X-ray testing in many industrial applications. There are different systems depending on the application, e.g. fast systems for detection of material inhomogeneities and slower systems with higher local resolution for detection of cracks and fine details, e.g. in highly stressed areas or in welded seams. The method is more dynamic than film methods, and digital image processing is possible during testing [de

  2. Materials testing by computerized tomography with neutrons and gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    El-Ghobary, A M; Bakkoush, F A; Megahid, R M [Reactor and Neutron Physics Department, Nuclear Research Center, A.E.A., Cairo (Egypt)

    1997-12-31

    The method of computerized tomography by fast neutrons and gamma-rays are used for inspecting and testing of materials by non-destructive technique. The transmission technique was applied using narrow collimated beams of reactor neutrons and gamma-ray. The neutron and gamma-rays transmitted through the object inspection were measured by means of a neutron gamma detector with Ne - 213 liquid organic scintillator. The undesired pulses of neutrons or gamma-rays are rejected from the transmitted beam by a discrimination technique based on the difference in the decay part of light pulse produced by recoil electrons or recoil protons. The transmitted neutrons or gamma-rays for different projections used to get the image of the section through the object investigated using the method of filtered back projection (FBP) algorithm. 8 figs.

  3. Exposure of patients and creation of system of quality assurance in conventional x-ray radiology in Lithuania

    International Nuclear Information System (INIS)

    Morkunas, G.; Ziliukas, J.

    1999-01-01

    One of the most important sources of exposure is medical application of ionizing radiation. X-ray examination comprise a significant part of medical exposure. Doses received by patients and quality of diagnostic images are to be optimized. Measurements of these doses were started by the Radiation Protection Centre in 1997. These measurements are performed in randomly selected x-ray departments all around Lithuania during examinations of chest and lumbar spine. Dose and parameters related to exposure and patient are registered. Quality control measurements by PMX-III are being performed on each x-ray machine used for examination. The results show that in many cases the guidance levels are of entrance surface dose for standard patient determined by the Basic Radiation Protection Standard of Lithuania are exceeded. Quality control of x-ray machines performed in 1997-1999 shows that more than 30% of these machines did not comply with the requirements though in many cases shortcomings are minor and easily removed. (au)

  4. Interferometric and optical tests of water window imaging x ray microscopes

    Science.gov (United States)

    Johnson, R. Barry

    1993-01-01

    Interferometric tests of Schwarzchild X-ray Microscope are performed to evaluate the optical properties and alignment of the components. Photographic measurements of the spatial resolution, focal properties, and vignetting characteristics of the prototype Water Window Imaging X-ray Microscope are made and analyzed.

  5. Seed viability of five wild Saudi Arabian species by germination and X-ray tests

    Directory of Open Access Journals (Sweden)

    B.A. Al-Hammad

    2017-09-01

    Full Text Available Our objective was to evaluate the usefulness of the germination vs. the X-ray test in determining the initial viability of seeds of five wild species (Moringa peregrina, Abrus precatorius, Arthrocnemum macrostachyum, Acacia ehrenbergiana and Acacia tortilis from Saudi Arabia. Usually several days were required to determine the viability of all five species via germination tests. However, X-ray test will give immediate results on filled/viable seeds. Seeds of all species, except Acacia ehrenbergiana and Acacia tortilis showed high viability in both germination (96–72% at 25/15 °C, 94–70% at 35/25 °C and X-ray (100–80% test. Furthermore, there was a general agreement between the germination (19%, 14% at 25/15 °C and 17% and 12% at 35/25 °C and X-ray (8%, 4% tests in which seed viability of Acacia ehrenbergiana and Acacia tortilis was very low due to insect damaged embryo as shown in X-ray analysis. Seeds of Abruspreca torius have physical dormancy, which was broken by scarification in concentrated sulfuric acid (10 min, and they exhibited high viability in both the germination (83% at 25/15 °C and 81% at 35/25 °C and X-ray (96% tests. Most of the nongerminated seeds of the five species except those of Acacia ehrenbergiana and Acacia tortilis, were alive as judged by the tetrazolium test (TZ. Thus, for the five species examined, the X-ray test was proved to be a good and rapid predictor of seed viability.

  6. Pursuing the Qualities of a "Good" Test

    Science.gov (United States)

    Coniam, David

    2014-01-01

    This article examines the issue of the quality of teacher-produced tests, limiting itself in the current context to objective, multiple-choice tests. The article investigates a short, two-part 20-item English language test. After a brief overview of the key test qualities of reliability and validity, the article examines the two subtests in terms…

  7. Diagnostic X-ray equipment evaluation in Brazil

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Peixoto, J.E.; Reis, V.R.G.

    1980-01-01

    A survey of the diagnostic X-ray equipment in use in Brazil is presented. Procedures for testing radiation quality (kilovoltage and filtration), tube output, beam collimation and protection devices are described and results of tests are tabulated. (H.K.)

  8. Quality-assurance techniques used with automated analysis of gamma-ray spectra

    International Nuclear Information System (INIS)

    Killian, E.W.; Koeppen, L.D.; Femec, D.A.

    1994-01-01

    In the course of developing gamma-ray spectrum analysis algorithms for use by the Radiation Measurements Laboratory at the Idaho National Engineering Laboratory (INEL), several techniques have been developed that enhance and verify the quality of the analytical results. The use of these quality-assurance techniques is critical when gamma-ray analysis results from low-level environmental samples are used in risk assessment or site restoration and cleanup decisions. This paper describes four of the quality-assurance techniques that are in routine use at the laboratory. They are used for all types of samples, from reactor effluents to environmental samples. The techniques include: (1) the use of precision pulsers (with subsequent removal) to validate the correct operation of the spectrometer electronics for each and every spectrum acquired, (2) the use of naturally occurring and cosmically induced radionuclides in samples to help verify that the data acquisition and analysis were performed properly, (3) the use of an ambient background correction technique that involves superimposing (open-quotes mappingclose quotes) sample photopeak fitting parameters onto multiple background spectra for accurate and more consistent quantification of the background activities, (4) the use of interactive, computer-driven graphics to review the automated locating and fitting of photopeaks and to allow for manual fitting of photopeaks

  9. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  10. Impact of quality control radiation doses received by patients undergoing abdomen x-ray examination in ten hospitals

    International Nuclear Information System (INIS)

    Aghahadi, B.; Zhang, Z.; Zareh, S.; Sarkar, S.; Tayebi, P. S.

    2006-01-01

    The X-ray machines used for radiodiagnosis should meet certain quality assurance programmes. These are necessary to have good quality radiographs at reasonably low exposure to patients. Materials and Methods: Dose reduction methods in abdomen X-ray examination were carried out in 10 hospitals in Tehran. This paper presents the work, which was implemented on 200 patients and evaluated using the entrance skin dose in the Anterior-Posterior abdomen projection measured directly at the center of the X-ray field. In addition, the machine room, and dark room parameters, as well as work practices and repeat rates were studied. Results: The quality control parameters and the entrance skin dose were evaluated utilizing an anthropologic phantom to define the optimal exposure condition at all hospitals before and after quality control . Results show that after using the quality control parameters and optimization of the exposure conditions, the mean of mAs and entrance skin dose can be decreased by 62% and 65% respectively. Conclusion: The quality of the radiographs generally increased. The reported method is easily implemented in any clinical situation where optimization of abdomen radiography is necessary

  11. Surface quality inspection of PbWO4 crystals by grazing incidence X-ray diffraction

    International Nuclear Information System (INIS)

    Mengucci, P.; Di Cristoforo, A.; Lebeau, M.; Majni, G.; Paone, N.; Pietroni, P.; Rinaldi, D.

    2005-01-01

    High-quality scintillating crystals are required for applications in radiographic systems and high-energy physics detectors to achieve the specified optical properties. In order to study the state of the single crystals surface we propose the use of the grazing incidence X-ray diffraction (GID) technique. This technique allows performing a depth profiling of the sample by changing the incidence angle of the X-ray beam with respect to the sample surface. In this work, two samples of a large PbWO 4 (PWO) single crystal exhibiting different surface roughness values have been studied. Results have shown that GID is a suitable technique for surface quality inspection

  12. Comparison of the results for quality implementation of low energy X rays

    International Nuclear Information System (INIS)

    Affonseca, M; Ochoa, R; Almeida, C.E. de; Peixoto, J.G.

    2001-01-01

    It describes the comparison of the results for qualities implementation of low energy X rays, using a pan tak tube, HF 160, which has tungsten white, beryllium window, is water-cooled and it has a 160 K B generator [es

  13. Muskuloskeletal radiography as a specialty. A quality improvement project on positioning of musculoskeletal x-rays with a multimethodology and multidisciplinary approach

    DEFF Research Database (Denmark)

    Jensen, Janni; Torfing, Trine

    treatment and/or unfavorable outcome for the patient. Guidelines developed by “European Guidelines on Quality Criteria for Diagnostic Radiographic Images” provide quality assessment tools regarding the technical aspect of x-rays (i.e. noise and resolution). One could argue what the quality of a perfectly......, i.e. the radiographers working with muskuloskeletal x-rays are specialized within this field. The primary purposes of this project are to perform continuous quantitative quality assessment and improvement of positioning of muskuloskeletal x-rays. Methods It has not yet been possible to find any...... of muskuloskeletal x-rays held by a radiologist, a reporting radiographer and an orthopedic surgeon, all from OUH • Radiographers are offered one-hour individual sessions with a reporting radiographer reviewing their own X-rays discussing positioning and pathology focusing on the association between positioning...

  14. Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums

    International Nuclear Information System (INIS)

    Park, Jong Kil; Maeng, Seong Jun; Lee, Yeon Ee; Hwang, Tae Won

    2008-01-01

    The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: the proper X-ray energy is under 3 MeV to test the drums of 320 β and less; both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  15. Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.

    Science.gov (United States)

    Lester, Sally; Harr, K E; Rishniw, Mark; Pion, Paul

    2013-01-15

    Quality assurance is an implied concept inherent in every consumer's purchase of a product or service. In laboratory testing, quality assurance encompasses preanalytic (sampling, transport, and handling prior to testing), analytic (measurement), and postanalytic (reporting and interpretation) factors. Quality-assurance programs require that procedures are in place to detect errors in all 3 components and that the procedures are characterized by both documentation and correction of errors. There are regulatory bodies that provide mandatory standards for and regulation of human medical laboratories. No such regulations exist for veterinary laboratory testing. The American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards Committee was formed in 1996 in response to concerns of ASVCP members about quality assurance and quality control in laboratories performing veterinary testing. Guidelines for veterinary laboratory testing have been developed by the ASVCP. The purpose of this report was to provide an overview of selected quality-assurance concepts and to provide recommendations for quality control for in-clinic biochemistry testing in general veterinary practice.

  16. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  17. Testing of X-ray radiometric enrichnment of polymetallic ores

    International Nuclear Information System (INIS)

    Eliseev, N.I.; Panova, N.I.; Kirbitova, N.V.; Shramm, E.O.; Efremov, Yu.G.

    1987-01-01

    Testing of X-ray radiometric method of sorting of polymetallic ores using the developed X-ray radiometric device was conducted. It was shown that introduction of preliminary concentration at the factory made the method of fragment separation to be the perspective one, enabling to elevate the factory production with respect to commercial ore and reduce the cost of ore processing. In the case of preliminary concentration, conducted at the mine, it is advisable to perform ore sorting in the flow formed to monolayer

  18. A device for checking the speeds and quality of X-ray films and efficiency of film processors

    International Nuclear Information System (INIS)

    Crooks, H.E.

    1980-01-01

    In order to carry out quality assurance tests of X-ray films, screens and processors, a standard exposure source of utmost reliability is desirable. The performance of apparatus containing yellow-green light emitting radioactive tritium activated phosphor, known as Betalight, is described. Over a period of 2 1/2 years, variations in film speeds up to +- 20% from nominally the same types of film have been observed. Additionally, substandard developer has been easily identified with the use of this device. The device is cheap and easy to manufacture, accurate and simple to use. (U.K.)

  19. The influence of the oblique incident X-ray that affected the image quality of the X-ray CCD sensor

    International Nuclear Information System (INIS)

    Suzuki, Yosuke; Matsumoto, Nobue; Morita, Hiroshi; Ohkawa, Hiromitsu

    1998-01-01

    The influence of the oblique incident X-ray that affected the image quality of the X-ray CCD sensor was examined and its correction was investigated. CDR was adopted in this study and evaluated image quality, by measuring MTF. The oblique projection was clinically permissible to about an oblique incident angle of 40 degrees although it exerts an influence on the magnifying power and density. The estimation of the oblique entrance direction and oblique incident angle was possible, by developing an oblique incident correction marker. When an oblique incident angle of θ degrees was measured, a correction is possible, by compressing the image cos (θ) times perpendicular to the rotational axis of CCD sensor. There was small decline of MTF, in the image where a correction for the influence of oblique incidence was made. By observation of the digital subtracted picture of the image after correction of oblique projection and that of normal, the resemblance in the two images indicated that this correction method was reasonable. (author)

  20. Design, Construction, and Testing of Lightweight X-ray Mirror Modules

    Science.gov (United States)

    McClelland, Ryan S.; Biskach, Michael P.; Chan, Kai-Wing; Espina, Rebecca A.; Hohl, Bruce R.; Matson, Elizabeth A.; Saha, Timo C.; Zhang, William W.

    2013-01-01

    Lightweight and high resolution optics are needed for future space-based X-ray telescopes to achieve advances in high-energy astrophysics. The Next Generation X-ray Optics (NGXO) team at NASA GSFC is nearing mission readiness for a 10 arc-second Half Power Diameter (HPD) slumped glass mirror technology while laying the groundwork for a future 1-2 arc-second technology based on polished silicon mirrors. Technology Development Modules (TDMs) have been designed, fabricated, integrated with mirrors segments, and extensively tested to demonstrate technology readiness. Tests include X-ray performance, thermal vacuum, acoustic load, and random vibration. The thermal vacuum and acoustic load environments have proven relatively benign, while the random vibration environment has proven challenging due to large input amplification at frequencies above 500 Hz. Epoxy selection, surface preparation, and larger bond area have increased bond strength while vibration isolation has decreased vibration amplification allowing for space launch requirements to be met in the near term. The next generation of TDMs, which demonstrates a lightweight structure supporting more mirror segments, is currently being fabricated. Analysis predicts superior performance characteristics due to the use of E-60 Beryllium-Oxide Metal Matrix Composite material, with only a modest cost increase. These TDMs will be larger, lighter, stiffer, and stronger than the current generation. Preliminary steps are being taken to enable mounting and testing of 1-2 arc-second mirror segments expected to be available in the future. A Vertical X-ray Test Facility (VXTF) will minimize module gravity distortion and allow for less constrained mirror mounts, such as fully kinematic mounts. Permanent kinematic mounting into a modified TDM has been demonstrated to achieve 2 arc-second level distortion free alignment.

  1. Development of improved x-ray optics for analytical x-ray microbeams. CRADA final report for CRADA Number Y-1294-0283

    International Nuclear Information System (INIS)

    Carpenter, D.A.; Gao, N.; Xiao, Q.F.; Ponomarev, I.

    1996-01-01

    The purpose of this CRADA was to develop improved glass capillary, x-ray optics for analytical x-ray microbeam applications. X-Ray Optical Systems, Inc. (XOS) designed and fabricated capillary optics and LMES tested those optics for x-ray microanalytical applications using its unique X-Ray Microprobe. Tapered capillaries with 3-microm and 8-microm output openings were fabricated and tested. The tapered capillaries had better spectral quality for x-ray microfluorescence (XRMF) analysis, than non-tapered, straight capillaries that are currently used in the system. X-ray beam count-rates for the tapered capillaries were also greater than the straight capillaries. Two monolithic, polycapillary optics were fabricated and tested. The polycapillary optics produced focal spots of 40 and 100 microm. Beam intensities for the polycapillaries were, respective, 44 and 18 times the intensities found in straight 50-microm and 100-microm capillaries. High-sensitivity scanning will be possible because of the enhanced intensity of the polycapillary optic. LMES and the DP program will benefit from improved capabilities for nondestructive x-ray microanalysis, while XOS will benefit from test results that will enhance the marketability of their products

  2. Physics-based optimization of image quality in 3D X-ray flat-panel cone-beam imaging

    NARCIS (Netherlands)

    Snoeren, R.M.

    2012-01-01

    This thesis describes the techniques for modeling and control of 3D X-ray cardiovascular systems in terms of Image Quality and patient dose, aiming at optimizing the diagnostic quality. When aiming at maximum Image Quality (IQ), a cascaded system constituted from inter-dependent imaging components,

  3. X ray reflection masks: Manufacturing, characterization and first tests

    Science.gov (United States)

    Rahn, Stephen

    1992-09-01

    SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  4. Assessment of image quality in x-ray radiography imaging using a small plasma focus device

    International Nuclear Information System (INIS)

    Kanani, A.; Shirani, B.; Jabbari, I.; Mokhtari, J.

    2014-01-01

    This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm. - Highlights: • We investigated a small plasma focus as pulsed x-ray source for radiography applications. • The image quality was studied by several parameters such as image contrast, LSF and MTF. • The x-ray source focal spot was obtained to be ∼0.6 mm using the penumbra imaging method. • The x-ray dose measurement showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. • The profiles of LSF and MTF showed that the cut-off frequency is about 1.5 cycles/mm

  5. Tests of lobster eye optics for small space X-ray telescope

    International Nuclear Information System (INIS)

    Tichy, Vladimir; Barbera, Marco; Collura, Alfonso; Hromcik, Martin; Hudec, Rene; Inneman, Adolf; Jakubek, Jan; Marsik, Jiri; Marsikova, Veronika; Pina, Ladislav; Varisco, Salvatore

    2011-01-01

    The Lobster eye design for a grazing incidence X-ray optics provides wide field of view of the order of many degrees, for this reason it can be a convenient approach for the construction of space all-sky X-ray monitors. We present preliminary results of tests of prototype lobster eye X-ray optics in quasi parallel beam full imaging mode conducted using the 35 m long X-ray beam-line of INAF-OAPA in Palermo (Italy). X-ray images at the focal plane have been taken with a microchannel plate (MCP) detector at several energy values from 0.3 to 8 keV. The gain, the field of view and the angular resolution have been measured and compared with theoretical values.

  6. Development of a dosimetric system for dental X-ray equipment quality control

    International Nuclear Information System (INIS)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  7. A contribution to quality control in veterinary radiology. Development and calibration of a test-phantom for the control of the picture quality of radiographs of the abdomen of the cat

    International Nuclear Information System (INIS)

    Mueller-Wabro, A.

    1996-10-01

    The theme of this thesis was the extension of the application of a test phantom developed at the institute of medical physics (University of Veterinary Medicine/Vienna) and the calibration for the abdomen of the cat. The test phantom is a stepped test body consisting of a material, which absorbs and scatters X-rays similar to bony tissue. On the baseplate of the staircase there are holes 0.5 and 0.7 mm in diameter. Objective parameters of a radiograph - radiographic density latitude, contrast and detail visibility - can be examined with the phantom. By using subjective 'good' rated radiographs it was possible to establish an indirect relation between the soft tissue of the abdomen and the phantom by comparing the optical density. Thus the practicability of the application for abdominal radiographs could be demonstrated. The recognizability of the holes means a measure of detail visibility. For the represented parameters of an X-ray picture are connected, one can conclude radiograph quality from detail visibility. On the basis of the results of a judgement by test-persons a nomogram was designed, which is of use in quick classifying and controlling X-ray pictures. (author)

  8. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  9. Use of X - Rays for the evaluation of internal damages provoked by corn seed drying and the effect of those damages upon the seeds quality

    International Nuclear Information System (INIS)

    Obando Flor, Ebert Pepe; Moreira de Carvalho, Maria Laene

    2002-01-01

    The work was conducted in the seed analysis laboratory of the department of agriculture and forest sciences of the Universidade Federal de Lavras (Federal University of Lavras. MG), over the period 1999 - 2000. Aiming to evaluate the efficiency of utilization of X - rays in the identification of the several types of internal damages provoked by corn seed drying to high temperatures as well as the effect of those damages upon the physiological quality of stored seeds, lots of the cultivars AG1143 and BR 106 were submitted to drying at the temperature of 50 degrades Celsius. The lots were divided into two categories according to the presence or not of internal damages visible with the naked eye submitted to the X - ray test (for 45 at 25 Kvp of radiation intensity) afterwards. They were separated into three sub lots. CDVCDRX (with visual damages and detected by X - ray) SDVSDRX (without visual damages and with damages detected by X ray). The sub lots were evaluated in their physiological quality by viability and vigor tests. The results showed the efficiency of X ray in detecting internal damages of drying not observed by visual analysis. The vigor of corn seeds with internal drying damages is affected in several manners, depending on the cultivars, evaluation time and sort of damage internal damages of drying detected by the radiographical analysis in spite of not affecting early viability, when they occurs in the two directions horizontal and vertical (Double damage) decrease the vigor of seeds after storage

  10. Gamma-Ray, Cosmic Ray and Neutrino Tests of Lorentz Invariance and Quantum Gravity Models

    Science.gov (United States)

    Stecker, Floyd

    2011-01-01

    High-energy astrophysics observations provide the best possibilities to detect a very small violation of Lorentz invariance such as may be related to the structure of space-time near the Planck scale of approximately 10(exp -35) m. I will discuss here the possible signatures of Lorentz invariance violation (LIV) from observations of the spectra, polarization, and timing of gamma-rays from active galactic nuclei and gamma-ray bursts. Other sensitive tests are provided by observations of the spectra of ultrahigh energy cosmic rays and neutrinos. Using the latest data from the Pierre Auger Observatory one can already derive an upper limit of 4.5 x 10(exp -23) to the amount of LIV of at a proton Lorentz factor of approximately 2 x 10(exp 11). This result has fundamental implications for quantum gravity models. I will also discuss the possibilities of using more sensitive space based detection techniques to improve searches for LIV in the future.

  11. Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, T.; Oda, K.; Sato, Y.; Ito, H.; Masuda, S.; Yamada, T.; Matsumoto, M.; Murayama, H.; Takei, H. [Allied Health Sciences, Kitasato University Kitasato 1-15-1, Minami-ku, Sagamihara-shi, Kanagawa 252-0373 (Japan); Positron Medical Center, Tokyo Metropolitan Institute of Gerontology Sakaecho 35-2, Itabashi-ku, Tokyo 173-0015 (Japan); Advanced Industrial Science and Technology (AIST) Central 2, Umezono 1-1-1, Tsukuba-shi, Ibaraki 305-8568 (Japan); Kanagawa Industrial Technology Center (KITC) Shimoimazumi 705-1, Ebina-shi, Kanagawa 243-0435 (Japan); Japan Radioisotope Association (JRIA) Komagome 2-28-45, Bunkyo-ku, Tokyo 113-8941 (Japan); Molecular Imaging Center, National Institute of Radiological Sciences Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Graduate School of Medical Sciences, Kitasato University Kitasato 1-15-1, Minami-ku, Sagamihara-shi, Kanagawa 252-0373 (Japan)

    2012-07-15

    Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

  12. X-ray mirror development and testing for the ATHENA mission

    Science.gov (United States)

    Della Monica Ferreira, Desiree; Jakobsen, Anders C.; Massahi, Sonny; Christensen, Finn E.; Shortt, Brian; Garnæs, Jørgen; Torras-Rosell, Antoni; Krumrey, Michael; Cibik, Levent; Marggraf, Stefanie

    2016-07-01

    This study reports development and testing of coatings on silicon pore optics (SPO) substrates including pre and post coating characterisation of the x-ray mirrors using Atomic Force Microscopy (AFM) and X-ray reflectometry (XRR) performed at the 8 keV X-ray facility at DTU Space and with synchrotron radiation in the laboratory of PTB at BESSY II. We report our findings on surface roughness and coating reflectivity of Ir/B4C coatings considering the grazing incidence angles and energies of ATHENA and long term stability of Ir/B4C, Pt/B4C, W/Si and W/B4C coatings.

  13. SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

    Science.gov (United States)

    Winternitz, Luke; Mitchell, Jason W.; Hassouneh, Munther A.; Valdez, Jennifer E.; Price, Samuel R.; Semper, Sean R.; Yu, Wayne H.; Ray, Paul S.; Wood, Kent S.; Arzoumanian, Zaven; hide

    2016-01-01

    The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the high-fidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars

  14. Radiation exposure and image quality in X-ray diagnostic radiology. Physical principles and clinical applications. 2. ed.

    International Nuclear Information System (INIS)

    Saebel, Manfred; Aichinger, Horst; Dierker, Joachim; Joite-Barfuss, Sigrid

    2012-01-01

    Diagnostic X-rays are the largest contributor to radiation exposure to the general population, and protecting the patient from radiation damage is a major aim of modern health policy. Once the decision has been taken to use ionising radiation for imaging in a particular patient, it is necessary to optimize the image acquisition process taking into account the diagnostic quality of the images and the radiation dose to the patient. Both image quality and radiation dose are affected by a number of parameters, knowledge of which permits scientifically based decision making. The authors of this second edition of Radiation Exposure and Image Quality in X-ray Diagnostic Radiology have spent many years studying the optimization of radiological imaging. In this book they present in detail the basic physical principles of diagnostic radiology and their application to clinical problems. Particular attention is devoted to evaluation of the dose to the patient, the influence of scattered radiation on image quality, the use of antiscatter grids, and optimization of image quality and dose. The final section is a supplement containing tables of data and graphical depictions of X-ray spectra, interaction coefficients, characteristics of X-ray beams, and other aspects relevant to patient dose calculations. In addition, a complementary CD-ROM contains a user-friendly Excel file database covering these aspects that can be used in the reader's own programs. Since the first edition, the text, figures, tables, and references have all been thoroughly updated, and more detailed attention is now paid to image quality and radiation exposure when using digital imaging and computed tomography. This book will be an invaluable aid to medical physicists when performing calculations relating to patient dose and image quality, and will also prove useful for diagnostic radiologists and engineers. (orig.)

  15. Quality of routine spirometry tests in Dutch general practices

    Science.gov (United States)

    Schermer, Tjard RJ; Crockett, Alan J; Poels, Patrick JP; van Dijke, Jacob J; Akkermans, Reinier P; Vlek, Hans F; Pieters, Willem R

    2009-01-01

    Background Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care. Aim To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics. Design of study Analysis of routine spirometry test records. Setting Fifteen general practices which had a working agreement with a local hospital pulmonary function laboratory for spirometry assessment regarding test quality and interpretation. Method Spirometry tests were judged by a pulmonary function technician and a chest physician. Proportions of test adequacy were analysed using markers for manoeuvre acceptability and test reproducibility derived from the 1994 American Thoracic Society spirometry guideline. Associations between quality markers and age, sex, and severity of obstruction were examined using logistic regression. Results Practices performed a mean of four (standard deviation = 2) spirometry tests per week; 1271 tests from 1091 adult patients were analysed; 96.4% (95% confidence interval [CI] = 95.6 to 97.2) of all tests consisted of ≥3 blows. With 60.6% of tests, forced expiratory time was the marker with the lowest acceptability rate. An overall 38.8% (95% CI = 36.0 to 41.6) of the tests met the acceptability as well as reproducibility criteria. Age, sex, and severity of obstruction were associated with test quality markers. Conclusion The quality of routine spirometry tests was better than in previous reports from primary care research settings, but there is still substantial room for improvement. Sufficient duration of forced expiratory time is the quality marker with the highest rate of inadequacy. Primary care professionals should be aware of patient characteristics that may diminish the quality of their spirometry tests. Further research is needed to establish to what extent spirometry tests that are inadequate, according to stringent international expert criteria

  16. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  17. Web Implementation of Quality Assurance (QA) for X-ray Units in Balkanic Medical Institutions.

    Science.gov (United States)

    Urošević, Vlade; Ristić, Olga; Milošević, Danijela; Košutić, Duško

    2015-08-01

    Diagnostic radiology is the major contributor to the total dose of the population from all artificial sources. In order to reduce radiation exposure and optimize diagnostic x-ray image quality, it is necessary to increase the quality and efficiency of quality assurance (QA) and audit programs. This work presents a web application providing completely new QA solutions for x-ray modalities and facilities. The software gives complete online information (using European standards) with which the corresponding institutions and individuals can evaluate and control a facility's Radiation Safety and QA program. The software enables storage of all data in one place and sharing the same information (data), regardless of whether the measured data is used by an individual user or by an authorized institution. The software overcomes the distance and time separation of institutions and individuals who take part in QA. Upgrading the software will enable assessment of the medical exposure level to ionizing radiation.

  18. Design and Tests of the Hard X-ray Polarimeter X-Calibur

    Directory of Open Access Journals (Sweden)

    M. Beilicke

    2014-12-01

    Full Text Available X-ray polarimetry promises to give qualitatively new information bout high-energy astrophysical sources, such as binary black hole  systems, micro-quasars, active galactic nuclei, and gamma-ray bursts. We designed, built and tested ahard X-ray polarimeter, X-Calibur, to be used in the focal plane of the InFOCuS grazing incidence hard X-ray telescope.X-Calibur combines a low-Z Compton scatterer with a CZT detector assembly to measure the polarization of 20−60 keV X-rays making use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation; in principal, a similar space-borne experiment could be operated in the 5−100 keV regime. X-Calibur achieves a high detection efficiency of order unity.

  19. Image and diagnosis quality of X-ray image transmission via cell phone camera: a project study evaluating quality and reliability.

    Directory of Open Access Journals (Sweden)

    Hans Goost

    Full Text Available INTRODUCTION: Developments in telemedicine have not produced any relevant benefits for orthopedics and trauma surgery to date. For the present project study, several parameters were examined during assessment of x-ray images, which had been photographed and transmitted via cell phone. MATERIALS AND METHODS: A total of 100 x-ray images of various body regions were photographed with a Nokia cell phone and transmitted via email or MMS. Next, the transmitted photographs were reviewed on a laptop computer by five medical specialists and assessed regarding quality and diagnosis. RESULTS: Due to their poor quality, the transmitted MMS images could not be evaluated and this path of transmission was therefore excluded. Mean size of transmitted x-ray email images was 394 kB (range: 265-590 kB, SD ± 59, average transmission time was 3.29 min ± 8 (CI 95%: 1.7-4.9. Applying a score from 1-10 (very poor - excellent, mean image quality was 5.8. In 83.2 ± 4% (mean value ± SD of cases (median 82; 80-89%, there was agreement between final diagnosis and assessment by the five medical experts who had received the images. However, there was a markedly low concurrence ratio in the thoracic area and in pediatric injuries. DISCUSSION: While the rate of accurate diagnosis and indication for surgery was high with a concurrence ratio of 83%, considerable differences existed between the assessed regions, with lowest values for thoracic images. Teleradiology is a cost-effective, rapid method which can be applied wherever wireless cell phone reception is available. In our opinion, this method is in principle suitable for clinical use, enabling the physician on duty to agree on appropriate measures with colleagues located elsewhere via x-ray image transmission on a cell phone.

  20. Commissioning and quality assurance of the x-ray volume imaging system of an image-guided radiotherapy capable linear accelerator

    International Nuclear Information System (INIS)

    Muralidhar, K.R.; Narayana Murthy, P.; Kumar, Rajneesh

    2008-01-01

    An Image-Guided Radiotherapy-capable linear accelerator (Elekta Synergy) was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI) system and electronic portal imaging device (iViewGT). The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer's specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality). These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy. (author)

  1. Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator

    Directory of Open Access Journals (Sweden)

    Muralidhar K

    2008-01-01

    Full Text Available An Image-Guided Radiotherapy-capable linear accelerator (Elekta Synergy was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI system and electronic portal imaging device (iViewGT. The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer′s specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality. These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy.

  2. [Study on seed quality test and quality standard of Pesudostellaria heterophylla].

    Science.gov (United States)

    Xiao, Cheng-Hong; Zhou, Tao; Jiang, Wei-Ke; Chen, Min; Xiong, Hou-Xi; Liao, Ming-Wu

    2014-08-01

    Referring to the rules for agricultural seed testing (GB /T 3543-1995) issued by China, the test of sampling, seed purity, weight per 1 000 seeds, seed moisture, seed viability and germination rate had been studied for screening seed quality test methods of Pesudostellaria heterophylla. The seed quality from different collection areas was measured. The results showed that at least 6.5 g seeds should be sampled and passed through 10-mesh sieve for purity analysis. The weight of 1 000 seeds was determined by using the 500-seed method. The phenotypic observation and size measurement were used for authenticity testing. The seed moisture was determined under the higher temperature (130 ± 2) degrees C for 5 hours. The seeds were dipped into 0.2% TTC sustaining 1 hour at 40 degrees C, then the viability could be determined. The break dormancy seeds were cultured on sand at 10 degrees C. K cluster analysis was applied for the data analysis, the seed quality from different collection areas grading of P. Heterophylla was described as three grades. The seed quality of each grade should reach following requirements: for first grade seeds, germination rate ≥ 86%, 1 000-grain weight ≥ 2.59 g, purity ≥ 87%, moisture ≤ 13.1%; for second grade seeds, germination rate ≥ 70%, 1 000-grain weight ≥ 2.40 g, purity ≥ 77%, moisture ≤ 14.3%; for third grade seeds, germination rate ≥ 41%, 1 000-grain weight ≥ 2.29 g, purity ≥ 76%, moisture ≤ 15.8%. The seed testing methods for quality items of P. heterophylla had been initially established, as well as the primary P. heterophylla seed quality classification standard.

  3. [Study on seed quality test and quality standard of Lonicera macranthoides].

    Science.gov (United States)

    Zhang, Ying; Xu, Jin; Li, Long-Yun; Cui, Guang-Lin; She, Yue-Hui

    2016-04-01

    Referring to the rules for agricultural seed testing (GB/T 3543-1995) issued by China, the test of sampling, purity, thousand seed weight, moisture, viability, relative conductivity and germination rate had been studied for seed quality test methods of Lonicera macranthoides. The seed quality from 38 different collection areas was measured to establish quality classification standard by K-means clustering. The results showed that at least 7.5 g seeds should be sampled, and passed 20-mesh sieve for purity analysis.The 500-seed method used to measure thousand seed weight. The moisture was determined by crushed seeds dried in high temperature (130±2) ℃ for 3 h.The viability determined by 25 ℃ 0.1% TTC stained 5h in dark. 1.0 g seeds soaked in 50 ml ultra pure water in 25 ℃ for 12 hours to determine the relative conductivity. The seed by 4 ℃stratification for 80 days were cultured on paper at 15 ℃. Quality of the seeds from different areas was divided into three grades. The primary seed quality classification standard was established.The I grade and II grade were recommend use in production. Copyright© by the Chinese Pharmaceutical Association.

  4. X-ray beam size measurements on the Advanced Test Accelerator

    International Nuclear Information System (INIS)

    Struve, K.W.; Chambers, F.W.; Lauer, E.J.; Slaughter, D.R.

    1986-01-01

    The electron beam size has been determined on the Advanced Test Accelerator (ATA) by intercepting the beam with a target and measuring the resulting x-ray intensity as a function of time as the target is moved through the beam. Several types of targets have been used. One is a tantalum rod which extends completely across the drift chamber. Another is a tungsten powder filled carbon crucible. Both of these probes are moved from shot to shot so that the x-ray signal intensity varies with probe position. A third is a larger tantalum disk which is inserted on beam axis to allow determining beam size on a one shot basis. The x-ray signals are detected with an MCP photomultiplier tube located at 90 0 to the beamline. It is sufficiently shielded to reject background x-rays and neutrons. The signals were digitized, recorded and later unfolded to produce plots of x-ray intensity versus probe position for several times during the pulse. The presumption that the x-ray intensity is proportional to beam current density is checked computationally. Details of the probe construction and PMT shielding, as well as sample measurements are given

  5. Organizing quality control programmes

    International Nuclear Information System (INIS)

    Hjardemaal, O.

    1989-01-01

    When procuring new equipment, performance and safety should be specified, if possible by reference to international standards. Some of the characteristics of the International Electrotechnical Commission (IEC) standard for X-ray generators, in particular the accuracy of the operating data, are described. The quality control tests to be performed after installation comprise acceptance test, status test and constancy test. The first two involve absolute measurements and will be the responsibility of physicists or engineers. Apparently limiting values stipulated by users are a factor of two lower than the limits of the IEC standard. By means of an example it is shown that modern X-ray generators can meet the lower limits of the users without problems. In order to obtain optimum initial quality when procuring new equipment operating data, limiting values must be specified and must be verified by acceptance testing, etc. However, in many countries physicists and engineers are not available for this job. A relatively uncomplicated test object can be used by radiographers for checks on fluoroscopic systems. The findings from such tests in Denmark are compared with other published findings and good agreement is found. Therefore it is proposed that such uncomplicated tests could form the basis for quality evaluation. (author)

  6. Benchmark test of 14-MeV neutron-induced gamma-ray production data in JENDL-3.2 and FENDL/E-1.0 through analysis of the OKTAVIAN experiments

    International Nuclear Information System (INIS)

    Maekawa, F.; Oyama, F.

    1996-01-01

    Secondary gamma rays play an important role along with neutrons in influencing nuclear design parameters, such as nuclear heating, radiation dose, and material damage on the plasma-facing components, vacuum vessel, and superconducting magnets, of fusion devices. Because evaluated nuclear data libraries are used in the designs, one must examine the accuracy of secondary gamma-ray data in these libraries through benchmark tests of existing experiments. The validity of the data should be confirmed, or problems with the data should be pointed out through these benchmark tests to ensure the quality of the design. Here, gamma-ray production data of carbon, fluorine, aluminum, silicon, titanium, chromium, manganese, cobalt, copper, niobium, molybdenum, tungsten, and lead in JENDL-3.2 and FENDL/E-1.0 induced by 14-MeV neutrons are tested through benchmark analyses of leakage gamma-ray spectrum measurements conducted at the OKTAVIAN deuterium-tritium neutron source facility. The MCNP transport code is used along with the flagging method for detailed analyses of the spectra. As a result, several moderate problems are pointed out for secondary gamma-ray data of titanium, chromium, manganese, and lead in FENDL/E-1.0. Because no fatal errors are found, however, secondary gamma-ray data for the 13 elements in both libraries are reasonably well validated through these benchmark tests as far as 14-MeV neutron incidence is concerned

  7. Application of different qualities of X-rays by X-ray microradiography to increase the detection efficiency of calcium

    International Nuclear Information System (INIS)

    Fernsebner, M.

    1981-01-01

    It was the goal of this work to evaluate quantitatively the suitability of the radiation quality of tungsten, copper, titanium and scandium anodes for the generation of contrastful microradiographs and thus to increase the detection sensitivity of calcium. Halfwidth determinations were made with aluminium absorbers in air to characterize the different X-ray radiation qualities. Furthermore the dependence of the dose load of the absorber width and the type of the tube was determined in the radiation field for 20 kV anode voltage. Reference step-models were established in order to transfer these results to the calcium detection in microradiograph technology. (orig./HBR) [de

  8. Data Organization for Quality Control Test

    International Nuclear Information System (INIS)

    Yahaya Talib; Glam Hadzir Patai Mohamad; Wan Hamirul Bahrin Wan Kamal

    2011-01-01

    Test data and results for quality control of Mo-99/ Tc-99m generator shall be organized properly. A computer program was developed using Visual Basic 6.0 to process test data, store data and results to specific folder, generate test reports and certificates. Its performance has been evaluated and tested. (author)

  9. Radiation exposure and image quality in x-Ray diagnostic radiology physical principles and clinical applications

    CERN Document Server

    Aichinger, Horst; Joite-Barfuß, Sigrid; Säbel, Manfred

    2012-01-01

    The largest contribution to radiation exposure to the population as a whole arises from diagnostic X-rays. Protecting the patient from radiation is a major aim of modern health policy, and an understanding of the relationship between radiation dose and image quality is of pivotal importance in optimising medical diagnostic radiology. In this volume the data provided for exploring these concerns are partly based on X-ray spectra, measured on diagnostic X-ray tube assemblies, and are supplemented by the results of measurements on phantoms and simulation calculations.

  10. Determination of seed viability of eight wild Saudi Arabian species by germination and X-ray tests.

    Science.gov (United States)

    Al-Turki, Turki A; Baskin, Carol C

    2017-05-01

    Our purpose was to evaluate the usefulness of the germination vs. the X-ray test in determining the initial viability of seeds of eight wild species ( Salvia spinosa , Salvia aegyptiaca , Ochradenus baccatus , Ochradenus arabicus , Suaeda aegyptiaca , Suaeda vermiculata , Prosopisfarcta and Panicumturgidum ) from Saudi Arabia. Several days were required to determine viability of all eight species via germination tests, while immediate results on filled/viable seeds were obtained with the X-ray test. Seeds of all the species, except Sa.aegyptiaca , showed high viability in both the germination (98-70% at 25/15 °C, 93-66% at 35/25 °C) and X-ray (100-75%) test. Furthermore, there was general agreement between the germination (10% at 25/15 °C and 8% at 35/25 °C) and X-ray (5%) tests that seed viability of Sa.aegyptiaca was very low, and X-ray analysis revealed that this was due to poor embryo development. Seeds of P.farcta have physical dormancy, which was broken by scarification in concentrated sulfuric acid (10 min), and they exhibited high viability in both the germination (98% at 25/15 °C and 93% at 35/25 °C) and X-ray (98%) test. Most of the nongerminated seeds of the eight species except those of Sa.aegyptiaca were alive as judged by the tetrazolium test (TZ). Thus, for the eight species examined, the X-ray test was a good and rapid predictor of seed viability.

  11. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing

    International Nuclear Information System (INIS)

    Ramamurthy, Senthil; D’Orsi, Carl J; Sechopoulos, Ioannis

    2016-01-01

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360° with a perforated tungsten plate in the path of the x-ray beam. To make patient testing feasible, a wirelessly controlled electronic positioner for the tungsten plate was designed and added to a breast CT system. Other improvements to the algorithm were implemented, including automated exclusion of non-valid primary estimate points and the use of a different approximation method to estimate the full scatter signal. To evaluate the effectiveness of the algorithm, evaluation of the resulting image quality was performed with a breast phantom and with nine patient images. The improvements in the algorithm resulted in the avoidance of introduction of artifacts, especially at the object borders, which was an issue in the previous implementation in some cases. Both contrast, in terms of signal difference and signal difference-to-noise ratio were improved with the proposed method, as opposed to with the correction algorithm incorporated in the system, which does not recover contrast. Patient image evaluation also showed enhanced contrast, better cupping correction, and more consistent voxel values for the different tissues. The algorithm also reduces artifacts present in reconstructions of non-regularly shaped breasts. With the implemented hardware and software improvements, the proposed method can be reliably used during patient breast CT imaging, resulting in improvement of image quality, no introduction of artifacts, and in some cases reduction of artifacts already present. The impact of the algorithm on actual clinical performance for detection, diagnosis and other clinical tasks in breast imaging remains to be evaluated. (paper)

  12. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  13. Characterization of different qualities in X-rays, for instruments calibration in radiological protection

    International Nuclear Information System (INIS)

    Cejudo A, J.; Tovar M, V. M.; Vergara M, F.

    2010-09-01

    In the Secondary Laboratory of Dosimetric Calibration in Mexico was realized the qualities characterization of the series X-rays RQR reported in the International Code of Practices in Dosimetry and Diagnostic Radiology No. 457, using attenuator filters of high purity aluminum and ionizing radiation equipment of inherent filtration of 4 mm Be with and emergent X-radiation beam of 40 grades. For the attenuation was used a geometric arrangement with three beam limiters and a monitor camera prepared on the established form in the mentioned technical report, and a spherical ionization chamber with collection volume of 3.6 cm 3 , aligning its geometric center with the focus of X-rays tube to get that the incident radiation direction will be perpendicular to the ionization chamber. From the perspective of the radiological protection is important to know the X-radiation quality for the application dedicated to the instruments calibration and can to give to these the traceability to a reference laboratory, this way the quality combination and reference chamber can give as a result a procedure for the evaluation of the entrance in surface dose to estimate the dose orientate levels, specified in the basic standards of safety. (Author)

  14. A Unique Outside Neutron and Gamma Ray Instrumentation Development Test Facility at NASA's Goddard Space Flight Center

    Science.gov (United States)

    Bodnarik, J.; Evans, L.; Floyd, S.; Lim, L.; McClanahan, T.; Namkung, M.; Parsons, A.; Schweitzer, J.; Starr, R.; Trombka, J.

    2010-01-01

    An outside neutron and gamma ray instrumentation test facility has been constructed at NASA's Goddard Space Flight Center (GSFC) to evaluate conceptual designs of gamma ray and neutron systems that we intend to propose for future planetary lander and rover missions. We will describe this test facility and its current capabilities for operation of planetary in situ instrumentation, utilizing a l4 MeV pulsed neutron generator as the gamma ray excitation source with gamma ray and neutron detectors, in an open field with the ability to remotely monitor and operate experiments from a safe distance at an on-site building. The advantage of a permanent test facility with the ability to operate a neutron generator outside and the flexibility to modify testing configurations is essential for efficient testing of this type of technology. Until now, there have been no outdoor test facilities for realistically testing neutron and gamma ray instruments planned for solar system exploration

  15. Identifying the cause of intermittent problems in diagnostic X-ray machines

    International Nuclear Information System (INIS)

    Addison, S.J.; O'Brien, M.J.; Robb, D.B.

    1987-01-01

    Quality assurance testing and performance evaluation of radiologic x-ray equipment is an important part of producing acceptable diagnostic quality images with minimum patient exposure. Regulatory and advisory agencies provide guidance for performing these tests, but it is often only obvious problems which are detected without extensive investigation. It is desirable for the Health Physicist to be able to determine the cause of an intermittent ''bad film'' with a minimum of test equipment. This paper relates some significant performance anomalies which have been identified in diagnostic x-ray equipment from installations in the Seattle area. Many of these problems eluded manufacturer's service personnel. Also included is a description of simple steps which can be included in test procedures to detect these equipment irregularities

  16. Dentistry 4. X-ray diagnostics

    International Nuclear Information System (INIS)

    2014-01-01

    DIN pocketbook 267/4 gives an overview of the normative requirements of the new X-Ray and Radiation Protection Ordinance, which has been in effect since 1 November 2011. This DIN pocketbook is intended for anyone charged with professional responsibility for the use of ionizing radiation in dentistry, operators and users of x-ray devices, radiation protection officers, accredited experts, manufacturers as well as for anyone with an interest in radiation protection or optimal radiological diagnostics. It contains standards relating to the following areas: acceptance and constancy testing; devices for evaluating findings (monitors, film viewing devices), films, printers; archiving, designating, labelling. Adherence to the standards makes it possible to avoid distractive artefacts in x-ray images and optimise the quality of x-ray diagnostics in dentistry.

  17. X-ray phase scanning setup for non-destructive testing using Talbot-Lau interferometer

    Science.gov (United States)

    Bachche, S.; Nonoguchi, M.; Kato, K.; Kageyama, M.; Koike, T.; Kuribayashi, M.; Momose, A.

    2016-09-01

    X-ray grating interferometry has a great potential for X-ray phase imaging over conventional X-ray absorption imaging which does not provide significant contrast for weakly absorbing objects and soft biological tissues. X-ray Talbot and Talbot-Lau interferometers which are composed of transmission gratings and measure the differential X-ray phase shifts have gained popularity because they operate with polychromatic beams. In X-ray radiography, especially for nondestructive testing in industrial applications, the feasibility of continuous sample scanning is not yet completely revealed. A scanning setup is frequently advantageous when compared to a direct 2D static image acquisition in terms of field of view, exposure time, illuminating radiation, etc. This paper demonstrates an efficient scanning setup for grating-based Xray phase imaging using laboratory-based X-ray source. An apparatus consisting of an X-ray source that emits X-rays vertically, optical gratings and a photon-counting detector was used with which continuously moving objects across the field of view as that of conveyor belt system can be imaged. The imaging performance of phase scanner was tested by scanning a long continuous moving sample at a speed of 5 mm/s and absorption, differential-phase and visibility images were generated by processing non-uniform moire movie with our specially designed phase measurement algorithm. A brief discussion on the feasibility of phase scanner with scanning setup approach including X-ray phase imaging performance is reported. The successful results suggest a breakthrough for scanning objects those are moving continuously on conveyor belt system non-destructively using the scheme of X-ray phase imaging.

  18. Indoor Air Quality Test House

    Data.gov (United States)

    Federal Laboratory Consortium — Description:In order to enable studies of a range of indoor air quality and ventilation issues, EL maintains a highly instrumented three-bedroom test house. Previous...

  19. Automated X-ray television complex for testing large dynamic objects

    International Nuclear Information System (INIS)

    Gusev, E.A.; Luk'yanenko, Eh.A.; Chelnokov, V.B.; Kuleshov, V.K.; Alkhimov, Yu.V.

    1992-01-01

    An automated X-ray television complex on the base of matrix gas-dischage large-area (2.1x1.0 m) converter for testing large cargoes and containers, as well as for inductrial article diagnostics is described. The complex pulsed operation with the 512 kbytes television digital memory unit provides for testing dynamic objects under minimal doses (20-100 μR)

  20. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Application of a tandem ionization chamber in a quality control program of X-ray beams, radiotherapy level

    International Nuclear Information System (INIS)

    Yoshizumi, Maira T.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber, developed at the Instituto de Pesquisas Energeticas e Nucleares (IPEN), for X radiation beams, radiotherapy level, was applied into a quality control program of the Calibration Laboratory of IPEN. This ionization chamber is composed by two ionization chambers, with a volume of 0.6 cm 3 each one. Its inner plane-parallel electrodes and guard rings are made of different materials: one is made of aluminum and the other is made of graphite. Because of this difference in materials, the ionization chamber forms a tandem system. The relative response of the calibration factors of both sides of the chamber allows an easy verification of the X-ray beam qualities stability. The ionization chamber was submitted to some tests to verify the stability of its response: leakage current before and after exposure, repeatability and reproducibility. The performance of the ionization chamber was satisfactory. (author)

  2. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-01-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing sensitometric properties and image quality separately are available, it is desirable to find a method by the use of which all the relevant properties could be tested together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas the radiographic image quality is tested at different kilovoltages and for different material thicknesses

  3. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  4. Modulating effect of dimethylbenzanthracene on gamma-ray mutagenesis in the soybean test system

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T. [National Inst. of Genetics, Mishima, Shizuoka (Japan); Inoue, T.

    1987-10-15

    Dimethylbenzanthracene (DMBA), a strong tumor initiator, did not show mutagenic activity in the soybean test system either alone or in combination with tumor promoter, TPA. In combination treatments with DMBA and gamma-rays, the mutagenicity of gamma-rays was not affected by post-treatment with DMBA. However, DMBA pre-treatment clearly reduced gammaray-ray induced spotting frequency, suggesting that DMBA affects mutagenesis in gamma-irradiated soybean cells.

  5. The Image Quality of a Digital Chest X-Ray Radiography System: Comparison of Quantitative Image Quality Analysis and Radiologists' Visual Scoring

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ji Ho [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Chung, Myung Jin [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Park, Darl; Kim, Won Taek; Kim, Yong Ho; Ki, Yong Kan; Kim, DFong Hyun; Lee, Ju Hee; Kim, Dong Won [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Jeon, Ho Sang [Reserach Institue for Convergence of Biomedical Science and Technology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of)

    2011-11-15

    To evaluate the performance of imaging devices, which should be periodically monitored to maintain high quality images to the radiologists. Additionally, this evaluation may prevent patients from radiation over-exposure. The most suitable engineering standard for imaging performance evaluation of digital X-ray thoracic images was determined. IEC 62220-1 standards were used to evaluate the performance of the images. In succession, the visibilities of overall image, pneumothorax, and humerus head in anthropomorphic thoracic phantom images were used to evaluate the image qualities by radiologists. The rank correlation coefficient (p) of visual scoring by radiologists with system spatial resolution is not meaningful (p-value, p = 0.295), but is significant with image noise (p-value, p -0.9267). Finally, the noise equivalent quanta (NEQ) presents a high rank correlation for visual scoring of radiologists (p-value, p = 0.9320). Image quality evaluation of radiologists were mainly affected by imaging noise. Hence, the engineered standard for evaluating image noise is the most important index to effectively monitor the performance of X-ray images. Additionally, the NEQ can be used to evaluate the performance of radiographic systems, because it theoretically corresponds to the synthetic image quality of systems.

  6. Fatigue damage observed non-destructively in fibre composite coupon test specimens by X-ray CT

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2016-01-01

    This study presents a method for monitoring the 3D fatigue damage progression on a micro-structural level in a glass fibre/polymer coupon test specimen by means of laboratory X-ray Computed Tomography (CT). A modified mount and holder made for the standard test samples to fit into the X-ray CT...... scanner along with a tension clamp solution is presented. Initially, the same location of the test specimen is inspected by ex-situ X-ray CT during the fatigue loading history, which shows the damage progression on a micro-structural level. The openings of individual uni-directional (UD) fibre fractures...

  7. Quality Control Assessment of Radiology Devices in Kerman Province, Iran

    OpenAIRE

    Zahra Jomehzadeh; Ali Jomehzadeh; Mohammad Bagher Tavakoli

    2016-01-01

    Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests were performed on 28 conventional radiographic X-ray units in Kerman governmental hospitals, based ...

  8. The high-precision x-ray tomograph for quality control of the ATLAS MDT muon spectrometer

    CERN Document Server

    Drakoulakos, D G; Maugain, J M; Rohrbach, F; Sedykh, Yu

    1997-01-01

    For the Large Hadron Collider (LHC) of the next millennium, a large general-purpose high-energy physics experiment, the ATLAS project, is being designed by a world-wide collaboration. One of its detectors, the ATLAS muon tracking detector, the MDT project, is on the scale of a very large industrial project: the design, the construction and assembly of twelve hundred large muon drift chambers are aimed at producing an exceptional quality in terms of accuracy, material reliability, assembly, and monitoring. This detector, based on the concept of very high mechanical precision required by the physics goals, will use tomography as a quality control platform. An X-ray tomograph prototype, monitored by a set of interferometers, has been developed at CERN to provide high-quality control of the MDT chambers which will be built in the collaborating institutes of the ATLAS project. First results have been obtained on MDT prototypes showing the validity of the X-ray tomograph approach for mechanical control of the detec...

  9. Non-destructive test for VHTR fuel using 160kV X-ray system in Hotcell

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jun; Yoo, Boung Ok; Choo, Yong sun; Baik Sang youl; Kim, Hee Moon; Ahn, Sang Bok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The research for VHTR which is one of the next generation reactor has been actively carried out. As a part of the research for VHTR, an irradiation examination for the VHTR fuel was performed to confirm an in-pile behavior in HANARO. The non-destructive test for the irradiated fuel is very important to understand the in-pile behavior of the fuel. Especially, the X-ray system is useful to observe the fuel shape without destruction. A dimensional change and defect of the fuel can be confirmed thorough the Xray system. Also, using the 3-D software and CT technology, the fuel shape can be intuitionally observed. The 450kV and 160kV X-ray system were installed and operated in IMEF hotcell. The 160kV X-ray system relatively using a low voltage is suitable to a small scale sample. And high resolution images can be obtained. In this study, the non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. Through these test, the possibility for the X-ray inspection of irradiated fuel was confirmed. The non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. The clear images of the irradiated coated particle were produced without the radiation damage during the Xray inspection. The X-ray images of the VHTR fuel will be utilized as the in-pile performance validation data.

  10. Non-destructive test for VHTR fuel using 160kV X-ray system in Hotcell

    International Nuclear Information System (INIS)

    Kim, Young Jun; Yoo, Boung Ok; Choo, Yong sun; Baik Sang youl; Kim, Hee Moon; Ahn, Sang Bok

    2016-01-01

    The research for VHTR which is one of the next generation reactor has been actively carried out. As a part of the research for VHTR, an irradiation examination for the VHTR fuel was performed to confirm an in-pile behavior in HANARO. The non-destructive test for the irradiated fuel is very important to understand the in-pile behavior of the fuel. Especially, the X-ray system is useful to observe the fuel shape without destruction. A dimensional change and defect of the fuel can be confirmed thorough the Xray system. Also, using the 3-D software and CT technology, the fuel shape can be intuitionally observed. The 450kV and 160kV X-ray system were installed and operated in IMEF hotcell. The 160kV X-ray system relatively using a low voltage is suitable to a small scale sample. And high resolution images can be obtained. In this study, the non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. Through these test, the possibility for the X-ray inspection of irradiated fuel was confirmed. The non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. The clear images of the irradiated coated particle were produced without the radiation damage during the Xray inspection. The X-ray images of the VHTR fuel will be utilized as the in-pile performance validation data.

  11. Quality assurance during preoperational testing and during startup operation

    International Nuclear Information System (INIS)

    Eisele, H.; Meyer, F.A.

    1980-01-01

    Rules and guidelines for the quality assurance. Quality assurance in the course of preoperational testing and the startup period: preoperational testing; hot functional test I; hot functional test II; initial making critical and zero power physics testing; power range testing. Startup documents: startup program; startup instructions; startup data sheet; startup sequence outlines; final startup reports. Advisory safety committee for nuclear startup. (orig./RW)

  12. Iowa Central Quality Fuel Testing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Land Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.

  13. Objective image quality parameters of relevance in practice, measured for film-screen combinations - a contribution to quality assurance activities

    International Nuclear Information System (INIS)

    Angerstein, W.; Wolf, M.

    1986-01-01

    Objective measurement of the physico-technical parameters determining the image quality is the fastest and most accurate method of quality testing of the systems. The parameters in case of X-ray intensifying screens are imaging quality, servicable life, and mechanical properties. (orig./DG) [de

  14. Establishing the standard X-ray beam qualities for calibration of dosimeters used in diagnostic radiology following IAEA-TRS457

    International Nuclear Information System (INIS)

    Duong Van Trieu; Ho Quang Tuan; Bui Duc Ky

    2014-01-01

    The determination of the patient dose needs to provide a reference dose for the patient that reference dose levels to assess the relative risk during X- ray diagnostic. This mission, We had established a number of standard beam qualities to perform calibrations of diagnostic dosimeters and methods of measuring patient dose in X-ray diagnostic. At radiation dosimetry room, we had establish RQR2, RQR3, RQR4, RQR5, RQR6 beam qualities based on IAEA-TRS457 documentation with homogeneity coefficient (h) for each beam quality in the range 0.7 - 0.8, and haft-value layers HVL1, HVL2 of experimental and IAEA is different about 10%. Established calibration method for diagnostic dosimeters as KAP meters, UNFORS dosimeters, and the TLD dosimeters, practical measurements of entrance surface air kerma on Shimadzu X-ray machines used phantom. (author)

  15. Quality Assurance Tests of the CMS Endcap RPCs

    CERN Document Server

    Ahmed, Ijaz; Hamid Ansari, M; Irfan Asghar, M; Asghar, Sajjad; Awan, Irfan Ullah; Butt, Jamila; Hoorani, Hafeez R; Hussain, Ishtiaq; Khurshid, Taimoor; Muhammad, Saleh; Shahzad, Hassan; Aftab, Zia; Iftikhar, Mian; Khan, Mohammad Khalid; Saleh, M

    2008-01-01

    In this note, we have described the quality assurance tests performed for endcap Resistive Plate Chambers (RPCs) at two different sites, Pakistan Atomic Energy Commission (PAEC) and National Centre for Physics (NCP), in Pakistan. This paper describes various quality assurance tests both at the level of gas gaps and the chambers. The data has been obtained at different time windows during the large scale production of CMS RPCs of RE2/2 and RE2/3 type. In the quality assurance tests, we have investigated parameters like dark current, strip occupancy, cluster size and efficiency of RPCs.

  16. Quality of outpatient care of children and adolescents in conventional X-ray diagnosis - a pilot study

    International Nuclear Information System (INIS)

    Tasch, C.; Duetting, T.; Zieger, B.; Troeger, J.

    1999-01-01

    Purpose: The aim of the study was to evaluate the current quality of the outpatient radiodiagnostic care of children and adolescents as demonstrated for the example of conventional X-ray procedures. Materials and Methods: A consecutive series of 166 outpatient X-rays, selected by fixed criteria, was analysed according to both diagnostic aspects and radiation protection. Results: The X-rays examined were mainly gathered from orthopedic and radiological practices and from hospital radiological departments. The majority of these outpatient X-rays showed significant deficiencies regarding exposure, appropriate field size, and focussing or positioning of the patient. After the evaluation of the 166 X-rays by a total-score, 25% (42/166) of the X-rays were considered to be diagnostically insufficient. Conclusions: Improvements in outpatient radiodiagnostics are necessary to ensure adequate radiodiagnostic care of children and adolescents. (orig.) [de

  17. Postharvest quality of dragon fruit (Hylocereus spp.) after x-ray irradiation quarantine treatment

    Science.gov (United States)

    The quality of three dragon fruit clones (Hylocereus sp.) was determined following x-ray irradiation for disinfestation of quarantine pests. Fruit were treated with irradiation doses of 0, 200, 400, 600, or 800 Gy and stored for 12 days at 10 °C. Irradiation did not affect soluble solids content, ti...

  18. Comparison of X-ray and gamma-ray dose-response curves for pink somatic mutations in Tradescantia clone 02

    International Nuclear Information System (INIS)

    Underbrink, A.G.; Kellerer, A.M.; Mills, R.E.; Sparrow, A.H.; Brookhaven National Lab., Upton, N.Y.

    1976-01-01

    Microdosimetric data indicate that the mean specific energy, xi, produced by individual charged particles from X rays and gamma rays is different for the two radiation qualities by nearly a factor of two. In order to test whether this influences the initial, linear component in the dose-effect relations, a comparison was made between dose-response curves for pink somatic mutations in Tradescantia clone 02 stamen hairs following X and gamma irradiations. Absorbed doses ranged from 2.66 to 300 rad. The results are in agreement with predictions made on the basis of microdosimetric data. At low doses gamma rays are substantially less effective than X rays. The RBE of gamma rays vs. X rays at low doses was approximately 0.6, a value lower than those usually reported in other experimental systems. (orig.) [de

  19. Feasibility study of gamma-ray medical radiography

    International Nuclear Information System (INIS)

    Alyassin, Abdalmajeid M.; Maqsoud, Hamza A.; Mashat, Ahmad M.; Al-Mohr, Al-Sayed; Abdulwajid, Subhan

    2013-01-01

    This research explores the feasibility of using gamma-ray radiography in medical imaging. We will show that gamma-ray medical radiography has the potential to provide alternative diagnostic medical information to X-ray radiography. Approximately one Ci Am-241 radioactive source which emits mono-energetic 59.5 keV gamma rays was used. Several factors that influence the feasibility of this study were tested. They were the radiation source uniformity, image uniformity, and image quality parameters such as contrast, noise, and spatial resolution. In addition, several gamma-ray and X-ray images were acquired using humanoid phantoms. These images were recorded on computed radiography image receptors and displayed on a standard monitor. Visual assessments of these images were then conducted. The Am-241 radioactive source provided relatively uniform radiation exposure and images. Image noise and image contrast were mainly dependent on the exposure time and source size, whereas spatial resolution was dependent on source size and magnification factor. The gamma-ray humanoid phantom images were of lower quality than the X-ray images mainly due to the low radioactivity used and not enough exposure time. Nevertheless, the gamma-ray images displayed most of the main structures contained in the humanoid phantoms. Higher exposure rates and thus lower exposure times were estimated for different pure Am-241 source sizes that are hypothesized to provide high quality images similar to X-ray images. For instance, a 10 mm source size of pure Am-241 with 7 s exposure time should produce images similar in contrast and noise to X-ray images. This research paves the way for the production and usage of a highly radioactive Am-241 source with the potential to lead to the feasibility of acceptable quality medical gamma-ray radiography. - Highlights: ► Characterized the performance of gamma-ray radiography. ► Displayed medical images of humanoid phantoms using gamma radiography. ► Am-241

  20. Study of test-mass charging process in the LISA missions due to diffuse γ-rays

    International Nuclear Information System (INIS)

    Finetti, N; Scrimaglio, R; Grimani, C; Fabi, M

    2009-01-01

    Gravitational inertial sensors will be placed on board the Laser Interferometer Space Antenna (LISA) and aboard its precursor mission LISA Pathfinder (LISA-PF) in order to detect low frequency gravitational waves in space. Free-floating test-masses (Au 7 Pt 3 cubes) will be housed in inertial sensors for detecting possible laser signal variations induced by gravitational waves. Charging of the LISA test-masses due to exposure of the spacecraft to cosmic radiation and energetic solar particles will affect operation of gravitational inertial sensors. In this paper we report on the role of diffuse γ-rays in charging the LISA and LISA-PF test-masses with respect to protons and helium nuclei. The diffuse γ-ray flux in the Galaxy has been interpolated taking into account the outcomes of recent calculations. A comparison with γ-ray observations gathered by different experiments (COMPTEL and EGRET, Milagro, Whipple, HEGRA, TIBET) has been carried out. Simulations of the test-mass charging process have been performed by means of the FLUKA2006.3b package. Monte Carlo simulations of the interaction of cosmic particles with the LISA spacecraft indicate that the diffuse γ-ray contribution to the average steady-state test-mass charging rate and to the single-sided power spectrum of the charge rate noise is marginal with respect to that due to galactic cosmic-rays.

  1. SU-E-I-52: Effect of Various X-Ray Beam Qualities On the Exposure Index

    International Nuclear Information System (INIS)

    Yasumatsu, S; Iwase, K; Shimizu, Y; Tanaka, N; Morishita, J

    2015-01-01

    Purpose: The exposure index (EI) proposed by the International Electrotechnical Commission (IEC) 62494-1 is expected to be utilized as a standard dose index by every manufacturer. The IEC recommended the usage of RQA5 for the EI. However, X-ray beam qualities, particularly in clinical practices, vary depending on the examination objects and exposure conditions, including usage of anti-scatter grids. We investigated the effects of the X-ray beam qualities other than RQA5 on the EI. Methods: The Xray beam qualities of RQA3, 5, 7, and 9 in IEC 61267 Ed. 1.0 were adopted in a computed radiography system. A uniform exposure without objects was performed to measure the exposure indicators (S values) and air kerma (K). The relational equations between the S values and K were derived for the determination of the EI values. The EI values for RQA3, 7, and 9 were compared to those for RQA5 at the fixed S values of 100, 200, 400, and 600. Finally, the half-value layers (HVLs) using four grids (ratio 6:1, 8:1, 10:1, and 12:1) for the RQA5 X-ray were compared to those with RQA3–9. Results: The EI values for RQA3, 7, and 9 were up to 35.3%, 11.8%, and 38.7% higher, respectively, than that for RQA5 at the S value of 600. The HVLs without grids and with various grids for RQA5 were 6.85 mm Al. and in the range of 6.94–7.29 mm Al. (ΔHVL: up to 0.44 mm Al.), respectively. This variation in the HVLs with grids was smaller than that observed for RQA3–9 (ΔHVL: 2.0–7.5 mm Al.). Conclusion: Although the usage of grids may not greatly affect the EI, the X-ray beam quality for the determination of the EI cannot be ignored in the clinical evaluation of the dose index

  2. A proposal for the rationalisation of medium energy x-ray qualities available at ARPANSA

    International Nuclear Information System (INIS)

    Kotler, L.

    2000-01-01

    Full text: At present, using the Seifert X-ray generator, ARPANSA offers 25 therapy/diagnostic qualities in the half value layer (HVL) range 0.35 mm Al to 3.98 mm Cu. However, as these qualities are not identical to that used by clients, some form of interpolation will necessarily be performed. On the basis that interpolation is acceptable in specification of chamber calibration factors, a rationalisation of the beam qualities offered by ARPANSA is suggested. Our measurements indicate that for each of the ionisation chamber models NE2571, NE2561 and NE2611 an individual model-specific relationship between calibration factor and photon quality exists and can be expressed analytically. Thus it is possible to perform measurements on a limited set of X ray qualities and interpolate using an analytic function. For each radiation quality, X-ray calibrations are performed as a two step process using a monitor chamber. Firstly, measurements with the primary standard allow the ratio (R p ) of the exposure (air-kerma) rate to the monitor chamber current to be calculated. Secondly, the ratio (R ch ) of the current from the client's chamber to that of the monitor chamber is measured. For each of the chamber types mentioned above, the following expressions apply with separately empirically determined parameters a,b and c for R p and R ch . For each chamber type, the calibration factor N x (N k which is R p /R xh can be re-expressed as a common expression A*(l-B 1 *exp(-C 1 *H))/(l-B 2 *exp(-C2*H)) with separately determined constants for the Al and Cu HVL ranges. For the three most commonly used therapy level chambers, an identical analytic expression with empirically determined parameters can be used to specify a continuous relationship between correction factor and HVL in mm Al and/or mm Cu using five chamber measurements to cover each range. For the Al HVL range, the fitted results are generally within ± 1% of measurements whilst for the Cu HVL range the fit is within ± 0

  3. Non-destructive test for irradiated fuels using X-ray CT system in hot-laboratory

    International Nuclear Information System (INIS)

    Kim, Heemoon; Kim, Gil-Soo; Yoo, Boung-Ok; Tahk, Young-Wook; Cho, Moon-Sung; Ahn, Sang-Bok

    2015-01-01

    To inspect inside of irradiated fuel rod for PIE in hotcell, neutron beam and X-ray have been used. Many hot laboratories in the world have shown the results for NDT by 2-D film data. Currently, computed image processing technology instead of film has been developed and CT was applied to the X-ray and neutron beam system. In this trend, our facility needed to set up X-ray system for irradiated fuel inspection and installed in hotcell with consideration of radiation damage. In this study, X-ray system was tested to be operated with radioactive samples and was performed to inspect fuel rods and observe internal damage and dimensional change. 450kV X-ray CT system was installed in hotcell with modification and tested to check image resolution and radiation damage. The image data were analyzed by 3-D computer software. 8 fuel plates and VHTR rods were inspected and measured internal shape and dimension

  4. Use of Quality Models and Indicators for Evaluating Test Quality in an ESP Course

    Directory of Open Access Journals (Sweden)

    IEVA RUDZINSKA

    2013-12-01

    Full Text Available Qualitative methods of assessment play a decisive role in education in general and in language learning in particular. The necessity to perform a qualitative assessment comes from both increased student competition in higher education institutions (HEIs, and hence higher demands for fair assessment, and a growing public awareness on higher education issues, and therefore the need to account for a wider circle of stakeholders, including society as a whole. The aim of the present paper is to study the regulations and laws pertaining to the issue of assessment in Latvian HEIs, as well as to carry out literature sources analysis about assessment in language testing, seeking to select criteria characterizing the quality of English for Specific Purposes (ESP tests and to apply the model of evaluating the quality of a language test on an example of a test in sport English, developed in a Latvian higher education institution. An analysis of the regulations and laws about assessment in higher education and literature sources about tests in language courses has enabled the development of a test quality model, consisting of seven intrinsic quality criteria: clarity, adequacy, deep approach, attractiveness, originality/similarity, orientation towards student learning result/process, test scoring objectivity/subjectivity. Quality criteria comprise eleven indicators. The reliability of the given model is evaluated by means of the whole model, its criteria and indicator Cronbach’s alphas and point-biserial (item-total correlations or discrimination indexes DI. The test was taken by 63 participants, all of them 2nd year full time students attending a Latvian higher education institution. A statistical data analysis was performed with SPSS 17.0. The results show that, although test adequacy and clarity is sufficiently high, attractiveness and deep approach should be improved. Also the reliability of one version of the test is higher than that of the other one

  5. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  6. Commentary: progress in optimization of patient dose and image quality in x-ray diagnostics

    International Nuclear Information System (INIS)

    Carlsson, G.A.; Chan, H.-P.

    1999-01-01

    X-ray diagnostics gives the largest contribution to the population dose from man-made radiation sources. Strategies for reduction of patient doses without loss of diagnostic accuracy are therefore of great interest to society and have been focussed in general terms by the ICRP (ICRP 1996) through the introduction of the concept of diagnostic reference levels. The European Union has stimulated research in the field, and, based on patient dose measurements and radiologists' appreciation of acceptable image quality, good radiographic techniques have been identified and recommended (EUR 1996a, b) for conventional screen-film imaging. These efforts have resulted in notable dose reductions in clinical practices (Hart et al 1996). In spite of 100 years of use of x-rays for diagnostics, the choice of technique parameters still relies to a great extent on experience. Scientific efforts to optimize the choice in terms of finding the parameter settings which yield sufficient image quality at the lowest possible cost in dose are still rare. True optimization requires (1) estimation of the image quality needed to make a correct diagnosis and (2) methods to investigate all possible means of achieving this image quality in order to be able to decide which of them gives the lowest dose. The paper by Tapiovaara, Sandborg and Dance published in this issue of Physics in Medicine and Biology (pages 537-559) addresses the optimization of paediatric fluoroscopy, a timely and important topic. Fluoroscopy procedures, used to guide x-ray examinations or interventional procedures, are little standardized and may result in high dose levels; radiation exposure in childhood is likely to result in a higher lifetime risk than the same exposure later in life. The authors represent an interesting mix of expertise within various scientific fields: the theory of medical imaging and assessment of image quality, the physics of diagnostic radiology and radiation dosimetry. They provide good insights

  7. SWEPP gamma-ray spectrometer system software test plan and report

    International Nuclear Information System (INIS)

    Femec, D.A.

    1994-09-01

    The SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory to assist in the characterization of the radiological contents of contact-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP). In addition to determining the concentrations of gamma-ray-emitting radionuclides, the software also calculates attenuation-corrected isotopic mass ratios of specific interest, and provides controls for SGRS hardware as required. This document presents the test plan and report for the data acquisition and analysis software associated with the SGRS system

  8. X-ray testing for short-time dynamic applications

    International Nuclear Information System (INIS)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried

    2017-01-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  9. Problems with film processing in medical X-ray imaging in Lithuania

    International Nuclear Information System (INIS)

    Sniureviciute, M.; Adliene, D.

    2005-01-01

    Optimisation in X-ray imaging in order to reduce patient doses during diagnostic X-ray examinations is a complex process given the high level of image quality required. When quality systems are implemented as a basis for optimisation, attention should be paid to the qualifications of the staff and quality control of the equipment and of the X-ray imaging procedures, as well as to the methods used to evaluate the quality of these procedures. Until recently, quality control procedures at health care institutions in Lithuania were limited to the testing of X-ray units. Since film processing is one of the most important factors influencing patient doses and image quality during X-ray examinations, in 2003 the Kaunas department of the Radiation Protection Centre organised inspections of film processing laboratories in 11 health care institutions - hospitals and outpatient departments - in the Kaunas region. Problems of non-compliance with requirements identified during these inspections are discussed in this paper. Most of the health care institutions inspected already had quality assurance programmes. However, the implementation of these programmes was sometimes erratic because of the insufficient attention paid to the film developing processes. The worst situation was found in 4 institutions where the films were developed manually. Only 3 of the 11 departments inspected had sensitometers and densitometers for quality control of the processing. In many cases there was no control of chemicals, film sensitivity and density, or else control was irregular. In only a few departments were the effects of repeated controls investigated and discussed. Despite the current problems occurring in medical X-ray diagnostic departments in Lithuania, the situation is rapidly improving. New equipment is being installed, new devices for quality control are being used and, last but not least, the view of hospital administrators, radiologists and laboratory workers towards quality

  10. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  11. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    Science.gov (United States)

    Murata, C. H.; Fernandes, D. C.; Lavínia, N. C.; Caldas, L. V. E.; Pires, S. R.; Medeiros, R. B.

    2014-02-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  12. Improving packaged food quality and safety. Part 1: synchrotron X-ray analysis.

    Science.gov (United States)

    López-Rubio, A; Hernandez-Muñoz, P; Catala, R; Gavara, R; Lagarón, J M

    2005-10-01

    The objective was to demonstrate, as an example of an application, the potential of synchrotron X-ray analysis to detect morphological alterations that can occur in barrier packaging materials and structures. These changes can affect the packaging barrier characteristics when conventional food preservation treatments are applied to packaged food. The paper presents the results of a number of experiments where time-resolved combined wide-angle X-ray scattering and small-angle X-ray scattering analysis as a function of temperature and humidity were applied to ethylene-vinyl alcohol co-polymers (EVOH), polypropylene (PP)/EVOH/PP structures, aliphatic polyketone terpolymer (PK) and amorphous polyamide (aPA) materials. A comparison between conventional retorting and high-pressure processing treatments in terms of morphologic alterations are also presented for EVOH. The impact of retorting on the EVOH structure contrasts with the good behaviour of the PK during this treatment and with that of aPA. However, no significant structural changes were observed by wide-angle X-ray scattering in the EVOH structures after high-pressure processing treatment. These structural observations have also been correlated with oxygen permeability measurements that are of importance when guaranteeing the intended levels of safety and quality of packaged food.

  13. Development of phantom periapical for control quality

    International Nuclear Information System (INIS)

    Mendes, J.M.S.; Sales Junior, E.S.; Ferreira, F.C.L.; Paschoal, C.M.M.

    2015-01-01

    This study aimed to develop a dental phantom with cysts for evaluation of periapical radiographs that was tested in private dental offices in the city of Maraba, northern Brazil. Through some tests with the object simulator (phantom) were obtained 12 periapical radiographs (one in each of the offices visited) that waking up to the standards of Ordinance No. 453 were visually evaluated by observing the physical parameters of exposure (kVp and mA), time revelation of the radiographic film, later the other radiographs were visually compared with C6 ray set as the default. Among the results, it was found that only two of the twelve rays cysts could not be viewed and, therefore, these two images were deemed unsuitable for accurate diagnosis in the 10 images the cysts could be displayed, however according the images have different qualities comparisons. In addition, it can be concluded that the performance of the phantom was highly satisfactory showing to be efficient for use in quality control testing of dental X-rays, the quality control of radiographs and continuing education of dental professionals for a price much more accessible. (authors)

  14. A Systems Engineering Approach to Quality Assurance for Aerospace Testing

    Science.gov (United States)

    Shepherd, Christena C.

    2015-01-01

    On the surface, it appears that AS91001 has little to say about how to apply a Quality Management System (QMS) to major aerospace test programs (or even smaller ones). It also appears that there is little in the quality engineering Body of Knowledge (BOK)2 that applies to testing, unless it is nondestructive examination (NDE), or some type of lab or bench testing associated with the manufacturing process. However, if one examines: a) how the systems engineering (SE) processes are implemented throughout a test program; and b) how these SE processes can be mapped to the requirements of AS9100, a number of areas for involvement of the quality professional are revealed. What often happens is that quality assurance during a test program is limited to inspections of the test article; what could be considered a manufacturing al fresco approach. This limits the quality professional and is a disservice to the programs and projects, since there are a number of ways that quality can enhance critical processes, and support efforts to improve risk reduction, efficiency and effectiveness.

  15. Chandra X-ray Center Science Data Systems Regression Testing of CIAO

    Science.gov (United States)

    Lee, N. P.; Karovska, M.; Galle, E. C.; Bonaventura, N. R.

    2011-07-01

    The Chandra Interactive Analysis of Observations (CIAO) is a software system developed for the analysis of Chandra X-ray Observatory observations. An important component of a successful CIAO release is the repeated testing of the tools across various platforms to ensure consistent and scientifically valid results. We describe the procedures of the scientific regression testing of CIAO and the enhancements made to the testing system to increase the efficiency of run time and result validation.

  16. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  17. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  18. Quality control and patient dose from X-ray examinations in some hospitals in Estonia

    International Nuclear Information System (INIS)

    Servomaa, A.; Rannikko, S.; Parviainen, T.; Holmberg, P.; Kuus, E.; Mueuersepps, T.; Jaerv, V.

    1995-01-01

    Quality control measurements of X ray diagnostic units were carried out in four hospitals in Estonia. Measurements were focused on the unit's technical performance, on image quality and on patient dose and film processing. The main problems are in the areas of image receptors and film processing: image receptors are of low speed type causing high patient doses and manual film processing results in low contrast and high base plus fog. Spatial resolution, both in film imaging and in image intensifiers, is reasonably good. It is recommended that quality assurance programmes be established, that basic measuring equipment be acquired and personnel assigned to perform such measurements be trained. (Author)

  19. Assessment of image quality in x-ray radiography imaging using a small plasma focus device

    Science.gov (United States)

    Kanani, A.; Shirani, B.; Jabbari, I.; Mokhtari, J.

    2014-08-01

    This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm.

  20. Parameters and definitions in applied technique quality test for nuclear magnetic resonance imaging system (NMRI)

    International Nuclear Information System (INIS)

    Lin Zhikai; Zhao Lancai

    1999-08-01

    During the past two decades, medical diagnostic imaging technique has achieved dramatic development such as CT, MRI, PET, DSA and so on. The most striking examples of them are the application of X ray computerized tomography (CT) and magnetic resonance imaging in the field of medical diagnosis. It can be predicted that magnetic resonance imaging (MRI) will definitely have more widespread prospects of applications and play more and more important role in clinical diagnosis looking forward to the development of image diagnostic technique for 21 st century. The authors also present the measuring methods for some parameters. The parameters described can be used for reference by clinical diagnosticians, operators on MRI and medical physicists who engages in image quality assurance (QA) and control (QC) in performing MRI acceptance test and routine test

  1. Effect of area x-ray beam equalization on image quality and dose in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Jerry; Xu Tong; Husain, Adeel; Le, Huy; Molloi, Sabee [Department of Radiological Sciences, University of California, Irvine, CA 92697 (United States)

    2004-08-21

    In mammography, thick or dense breast regions persistently suffer from reduced contrast-to-noise ratio (CNR) because of degraded contrast from large scatter intensities and relatively high noise. Area x-ray beam equalization can improve image quality by increasing the x-ray exposure to under-penetrated regions without increasing the exposure to other breast regions. Optimal equalization parameters with respect to image quality and patient dose were determined through computer simulations and validated with experimental observations on a step phantom and an anthropomorphic breast phantom. Three parameters important in equalization digital mammography were considered: attenuator material (Z = 13-92), beam energy (22-34 kVp) and equalization level. A Mo/Mo digital mammography system was used for image acquisition. A prototype 16 x 16 piston driven equalization system was used for preparing patient-specific equalization masks. Simulation studies showed that a molybdenum attenuator and an equalization level of 20 were optimal for improving contrast, CNR and figure of merit (FOM = CNR{sup 2}/dose). Experimental measurements using these parameters showed significant improvements in contrast, CNR and FOM. Moreover, equalized images of a breast phantom showed improved image quality. These results indicate that area beam equalization can improve image quality in digital mammography.

  2. Quality in the chemical analysis of biological matrices by fluorescence X-ray by energy dispersive

    International Nuclear Information System (INIS)

    Sousa, Evely E. de; Paiva, Jose Daniel S. de; Franca, Elvis J. de; Almeida, Macio E.S.; Cantinha, Rebeca S.; Hazin, Clovis A.

    2013-01-01

    The aim of this study was to obtain multielement analytical curves of high analytical rigor to the analysis of biological matrices by the technique of fluorescence x-ray energy dispersive - EDXRF. Calibration curves were constructed from the reference materials IAEA 140, IAEA 155, IAEA V8, V10 to the International Atomic Energy Agency - IAEA, and SRM1515, SRM 1547, SRM 1570a, SRM 1573a, SEM 1567a, to the National Institute of Standards and Technology - NIST. After energy calibration, all samples were subjected to vacuum to the analyzes by 100 seconds for each group of chemical elements. The voltages used were respectively 15 keV for chemical elements with less than atomic number 22 and 50 keV for the others. After the construction of the curves, the analytical quality was assessed by the analysis of a portion-test of the reference material SRM 2976, also produced by NIST. Based on the number of certified reference materials used for construction of calibration curves in this work, quality analytical protocol was originated with considerable reliability for quantification of chemical elements in biological samples by EDXR

  3. Quality assurance challenges in x-ray emission based analyses

    International Nuclear Information System (INIS)

    Papp, T.

    2005-01-01

    Complete text of publication follows. There is a large scatter in the results of X-ray analysis with solid-state detectors suggesting methodological origin. Although the PIXE (proton induced X-ray emission) analytical technique can work without relation to any physics, as was commented at the recent PIXE conference, one could argue that if the same technique is used for measuring physical quantities reveals problems, then perhaps potential methodological issues can not apriory be excluded. We present a simple example which could be interpreted as indications for methodological considerations. Recently an inter-comparison was made of analysis of the spectra measured at the laboratory of the International Atomic Energy Agency (IAEA). Four participating analytical software packages were used to evaluate the X-ray spectra. There are several thin metal samples spectra, for which common energy scale could not be established. The quality of the spectrum can be judged from the line shape. The line shape is parametrized by the full widths at half maximum (FWHM) of a peak and the so-called low energy tailing. Fitting the spectra individually we obtained FWHM squared values at different energies and determined the linear regression parameters. The parameters suggest a rather poor detector performance. It is generally assumed that the (FWHM) 2 values have a first order polynomial form as a function of X-ray energy. Having done a linear regression analysis, we can plot the standard residual, presented in Fig. 1, which clearly shows a three-sigma deviation. The probability to having a three-sigma deviation is 1%. In other words, the probability that these spectra are in accordance with the expected FWHM functional form is less than 1%. The main problem is that, although the composite spectra were analyzed using four different programs, the difficulty in interpreting the spectra was not commented upon by any of the participants in the inter-comparison. (author)

  4. Evaluation of quality assurance of some diagnostic x-ray machines in Khartoum state

    International Nuclear Information System (INIS)

    Mohammed, Sirelkatim Khogali

    2013-04-01

    Availability and the use of x-ray equipment in both private and government hospitals are on the increase today in Khartoum state. Quality control of such equipment is of particular importance to prevent avoidable high doses, radiation leakages and to ensure dose optimization. The results of quality control in this study indicated that: all centers were within the k Vp reproducibility level (5%). At k Vp 50 and 60 there were 93% of centers within the limit and 7% were out. For 70, 81 and 90 k Vp all centers were within the limit. 73% of centers were within the level of HVL test, but 27% of them were out of the limit 80% of centers had a linear relationship between m As and dose, but three centers had no linear relationship. For time reproducibility 80% of centers were within the time reproducibility and 13% were out of limit. The beam on control and indicator were available and functional for all centers. The warning light was present in one center. But 93% of centers, but 20% of centers had no window lead glass. Lead aprons were available and functional in all centers. The gloves were available and functional in 33% of centers. But in 67% of centers they were not present. Gonads shields were present in 33% of centers, but not available for 67% of centers.(Author)

  5. Dosemeter calibration in X-ray and in cobalt-60

    International Nuclear Information System (INIS)

    Silva, T.A. da

    1988-01-01

    Some tests about quality security for clinical dosemeter calibration in secondary standard dosimetry laboratory are described. The tests in gama calibration system, in X-ray calibration, in secondary standard dosimeter, in the dosemeter that will be calibrated, during the calibration and after the calibration are shown. (C.G.C.) [pt

  6. Skin reactions and quality of life after x-ray therapy of Basal cell carcinoma

    DEFF Research Database (Denmark)

    Skiveren, Jette; Mikkelsen, Maria Rudkjaer; Daugbjerg, Helle

    2012-01-01

    controls (P = 0.819). Three months after X-ray therapy eight patients had no skin reactions, 11 had slight atrophy, pigmentation change, and/or some hair loss, four had patch atrophy, moderate telangiectasia, and/or total hair loss. Conclusions. BCC has a negative effect on patients' quality of life...

  7. Higher quality of molecular testing, an unfulfilled priority: Results from external quality assessment for KRAS mutation testing in colorectal cancer.

    Science.gov (United States)

    Tembuyser, Lien; Ligtenberg, Marjolijn J L; Normanno, Nicola; Delen, Sofie; van Krieken, J Han; Dequeker, Elisabeth M C

    2014-05-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European Society of Pathology has been organizing an annual KRAS external quality assessment program since 2009. In 2012, 10 formalin-fixed, paraffin-embedded samples, of which 8 from invasive metastatic colorectal cancer tissue and 2 artificial samples of cell line material, were sent to more than 100 laboratories from 26 countries with a request for routine KRAS testing. Both genotyping and clinical reports were assessed independently. Twenty-seven percent of the participants genotyped at least 1 of 10 samples incorrectly. In total, less than 5% of the distributed specimens were genotyped incorrectly. Genotyping errors consisted of false negatives, false positives, and incorrectly genotyped mutations. Twenty percent of the laboratories reported a technical error for one or more samples. A review of the written reports showed that several essential elements were missing, most notably a clinical interpretation of the test result, the method sensitivity, and the use of a reference sequence. External quality assessment serves as a valuable educational tool in assessing and improving molecular testing quality and is an important asset for monitoring quality assurance upon incorporation of new biomarkers in diagnostic services. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  8. On beam quality and stopping power ratios for high-energy x-rays

    International Nuclear Information System (INIS)

    Johnsson, S.A.; Ceberg, C.P.; Knoeoes, T.; Nilsson, P.

    2000-01-01

    The aim of this work is to quantitatively compare two commonly used beam quality indices, TPR(20/10) and %dd(10) x , with respect to their ability to predict stopping power ratios (water to air), s w,air , for high-energy x-rays. In particular, effects due to a varied amount of filtration of the photon beam will be studied. A new method for characterizing beam quality is also presented, where the information we strive to obtain is the moments of the spectral distribution. We will show how the moments enter into a general description of the transmission curve and that it is possible to correlate the moments to s w,air with a unique and simple relationship. Comparisons with TPR(20/10) and %dd(10) x show that the moments are well suited for beam quality specification in terms of choosing the correct s w,air . (author)

  9. Quality of routine spirometry tests in Dutch general practices.

    NARCIS (Netherlands)

    Schermer, T.R.J.; Crockett, A.J.; Poels, P.J.P.; Dijke, J.J. van; Akkermans, R.P.; Vlek, H.F.; Pieters, W.R.

    2009-01-01

    BACKGROUND: Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care. AIM: To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics. DESIGN OF STUDY: Analysis

  10. Automated Defect Recognition as a Critical Element of a Three Dimensional X-ray Computed Tomography Imaging-Based Smart Non-Destructive Testing Technique in Additive Manufacturing of Near Net-Shape Parts

    Directory of Open Access Journals (Sweden)

    Istvan Szabo

    2017-11-01

    Full Text Available In this paper, a state of the art automated defect recognition (ADR system is presented that was developed specifically for Non-Destructive Testing (NDT of powder metallurgy (PM parts using three dimensional X-ray Computed Tomography (CT imaging, towards enabling online quality assurance and enhanced integrity confidence. PM parts exhibit typical defects such as microscopic cracks, porosity, and voids, internal to components that without an effective detection system, limit the growth of industrial applications. Compared to typical testing methods (e.g., destructive such as metallography that is based on sampling, cutting, and polishing of parts, CT provides full coverage of defect detection. This paper establishes the importance and advantages of an automated NDT system for the PM industry applications with particular emphasis on image processing procedures for defect recognition. Moreover, the article describes how to establish a reference library based on real 3D X-ray CT images of net-shape parts. The paper follows the development of the ADR system from processing 2D image slices of a measured 3D X-ray image to processing the complete 3D X-ray image as a whole. The introduced technique is successfully integrated into an automated in-line quality control system highly sought by major industry sectors in Oil and Gas, Automotive, and Aerospace.

  11. High gamma-rays irradiation tests of critical components for ITER (International Thermonuclear Experimental Reactor) in-vessel remote handling system

    International Nuclear Information System (INIS)

    Obara, Kenjiro; Kakudate, Satoshi; Oka, Kiyoshi

    1999-02-01

    In ITER, the in-vessel remote handling is inevitably required to assemble and maintain the activated in-vessel components due to deuterium and tritium operation. Since the in-vessel remote handling system has to be operated under the intense of gamma ray irradiation, the components of the remote handling system are required to have radiation hardness so as to allow maintenance operation for a sufficient length of time under the ITER in-vessel environments. For this, the Japan, European and Russian Home Teams have extensively conducted gamma ray irradiation tests and quality improvements including optimization of material composition through ITER R and D program in order to develop radiation hard components which satisfy the doses from 10 MGy to 100 MGy at a dose rate of 1 x 10 6 R/h (ITER R and D Task: T252). This report describes the latest status of radiation hard component development which has been conducted by the Japan Home Team in the ITER R and D program. The number of remote handling components tested is about seventy and these are categorized into robotics (Subtask 1), viewing system (Subtask 2) and common components (Subtask 3). The irradiation tests, including commercial base products for screening, modified products and newly developed products to improve the radiation hardness, were carried out using the gamma ray irradiation cells in Takasaki Establishment, JAERI. As a result, the development of the radiation hard components which can be tolerable for high temperature and gamma radiation has been well progressed, and many components, such as AC servo motor with ceramics insulated wire, optical periscope and CCD camera, have been newly developed. (author)

  12. High gamma-rays irradiation tests of critical components for ITER (International Thermonuclear Experimental Reactor) in-vessel remote handling system

    Energy Technology Data Exchange (ETDEWEB)

    Obara, Kenjiro; Kakudate, Satoshi; Oka, Kiyoshi [Department of Fusion Engineering Research, Naka Fusion Research Establishment, Japan Atomic Energy Research Institute, Naka, Ibaraki (Japan)] [and others

    1999-02-01

    In ITER, the in-vessel remote handling is inevitably required to assemble and maintain the activated in-vessel components due to deuterium and tritium operation. Since the in-vessel remote handling system has to be operated under the intense of gamma ray irradiation, the components of the remote handling system are required to have radiation hardness so as to allow maintenance operation for a sufficient length of time under the ITER in-vessel environments. For this, the Japan, European and Russian Home Teams have extensively conducted gamma ray irradiation tests and quality improvements including optimization of material composition through ITER R and D program in order to develop radiation hard components which satisfy the doses from 10 MGy to 100 MGy at a dose rate of 1 x 10{sup 6} R/h (ITER R and D Task: T252). This report describes the latest status of radiation hard component development which has been conducted by the Japan Home Team in the ITER R and D program. The number of remote handling components tested is about seventy and these are categorized into robotics (Subtask 1), viewing system (Subtask 2) and common components (Subtask 3). The irradiation tests, including commercial base products for screening, modified products and newly developed products to improve the radiation hardness, were carried out using the gamma ray irradiation cells in Takasaki Establishment, JAERI. As a result, the development of the radiation hard components which can be tolerable for high temperature and gamma radiation has been well progressed, and many components, such as AC servo motor with ceramics insulated wire, optical periscope and CCD camera, have been newly developed. (author)

  13. Characteristics determination of Tanka X-ray Diagnostic Machine Model RTO-125

    International Nuclear Information System (INIS)

    Trijoko, Susetyo; Nasukha; Suyati; Nugroho, Agung.

    1993-01-01

    Characteristics determination of Tanka X-ray diagnostic machine model RTO-125. The characteristics of X-ray machine used for examining patient should be known. The characteristics studied in this paper include : X-ray beam profile, coincidence of the light field with radiation field, peak voltage, radiation quality, stability of exposures, and linearity of exposures against time. Beam profile and radiation-field alignment were determined using X-ray film. Winconsin kVp test cassette was used to measure peak voltage. The quality of the radiation, represented by half-value layer (HVL), was measured using aluminium step-wedge. Stability and linearity of exposures were measured using ionization chamber detector having an air volume of 40 cc. The results of this study were documented for the TANKA X-ray machine model RTO-125 of PSPKR BATAN, and the method of this study could be applied for X-ray diagnostic machine in general. (authors). 6 refs., 2 tabs., 6 figs

  14. Relay for the automation of the exposition process in X-ray control of material quality

    International Nuclear Information System (INIS)

    Vladimirov, L.V.; Ermakova, T.N.; Krongauz, A.N.; Kurozaev, V.P.; Khlebtsevich, V.Yu.; Chernobrovov, S.V.; Shul'gina, Z.I.

    1977-01-01

    Discussed are the theoretical and experimental conceptions which constitute the basis for elaboration of an electronic relay intended for automation of the exposure process during X-ray inspection of the material quality. The operating principle and circuitry of the relay are described

  15. CHALLENGES OF SOFTWARE QUALITY ASSURANCE AND TESTING

    Directory of Open Access Journals (Sweden)

    Md.Shahadat Hossain

    2018-02-01

    Full Text Available Uncertainty exists in Software Company over the world. Software quality problem is leading issue for the software industry. The issue exists from 40 years or 50 years long. The industry is suffering and closing for this issue. In this circumstance, it is important to address and remove its root cause. Otherwise, day by day industry economic loss will increase. I figure out some vital challenges of software quality assurance and testing which have been facing by software industries. The research focused on several small and medium software companies of the world. This paper represents different category of challenges along with responsible stakeholders. This research finds out that testing tools are available testing elements are available testing process has improved but still software has some testing challenges. My research figured out the bottleneck of challenges and explained in this paper. Here software engineers have scope to improve & overcome those challenges. This paper suggests systematic approach to solve the problem.

  16. Software System for the Calibration of X-Ray Measuring Instruments

    International Nuclear Information System (INIS)

    Gaytan-Gallardo, E.; Tovar-Munoz, V. M.; Cruz-Estrada, P.; Vergara-Martinez, F. J.; Rivero-Gutierrez, T.

    2006-01-01

    A software system that facilities the calibration of X-ray measuring instruments used in medical applications is presented. The Secondary Standard Dosimetry Laboratory (SSDL) of the Nuclear Research National Institute in Mexico (ININ in Spanish), supports activities concerning with ionizing radiations in medical area. One of these activities is the calibration of X-ray measuring instruments, in terms of air kerma or exposure by substitution method in an X-ray beam at a point where the rate has been determined by means of a standard ionization chamber. To automatize this process, a software system has been developed, the calibration system is composed by an X-ray unit, a Dynalizer IIIU X-ray meter by RADCAL, a commercial data acquisition card, the software system and the units to be tested and calibrated. A quality control plan has been applied in the development of the software system, ensuring that quality assurance procedures and standards are being followed

  17. On the response of electronic personal dosimeters in constant potential and pulsed X-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Margarete C.; Silva, Teogenes; Silva, Claudete R.E., E-mail: margaretecristinag@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Oliveira, Paulo Marcio C. de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem

    2015-07-01

    Electronic personal dosimeters (EPDs) based on solid state detectors have widely been used but some deficiencies in their response in pulsed radiation beams have been reported. Nowadays, there is not an international standard for pulsed X-ray beams for calibration or type testing of dosimeters. Irradiation conditions for testing the response of EPDs in both the constant potential and pulsed X-ray beams were established in CDTN. Three different types of EPDs were tested in different conditions in similar ISO and IEC X-ray qualities. Results stressed the need of performing additional checks before using EPDs in constant potential or pulsed X-rays. (author)

  18. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  19. Spiked environmental matrix for use as a reference material for gamma-ray spectrometry: Production and homogeneity test

    International Nuclear Information System (INIS)

    Sobiech-Matura, K.; Máté, B.; Altzitzoglou, T.

    2016-01-01

    The application of a spiking method for reference material production and its utilisation for a food matrix is presented. The raw rice powder was tested by means of γ-ray spectrometry and spiked with a "1"3"7Cs solution. The spiked material was mixed and tested for homogeneity. The future use of the rice powder reference material after the entire characterisation cycle will be for γ-ray spectrometry method validation. - Highlights: • Spiking blank substance with a traceable radioactive solution • Spiked reference material for γ-ray emitting radionuclides in food matrix • Results of the homogeneity tests are presented

  20. Correlation between protein sequence similarity and x-ray diffraction quality in the protein data bank.

    Science.gov (United States)

    Lu, Hui-Meng; Yin, Da-Chuan; Ye, Ya-Jing; Luo, Hui-Min; Geng, Li-Qiang; Li, Hai-Sheng; Guo, Wei-Hong; Shang, Peng

    2009-01-01

    As the most widely utilized technique to determine the 3-dimensional structure of protein molecules, X-ray crystallography can provide structure of the highest resolution among the developed techniques. The resolution obtained via X-ray crystallography is known to be influenced by many factors, such as the crystal quality, diffraction techniques, and X-ray sources, etc. In this paper, the authors found that the protein sequence could also be one of the factors. We extracted information of the resolution and the sequence of proteins from the Protein Data Bank (PDB), classified the proteins into different clusters according to the sequence similarity, and statistically analyzed the relationship between the sequence similarity and the best resolution obtained. The results showed that there was a pronounced correlation between the sequence similarity and the obtained resolution. These results indicate that protein structure itself is one variable that may affect resolution when X-ray crystallography is used.

  1. Development of the water window imaging x-ray microscope

    International Nuclear Information System (INIS)

    Hoover, R.B.; Shealy, D.L.; Baker, P.C.; Barbee, T.W. Jr.; Walker, A.B.C. Jr.

    1991-01-01

    This paper reports on the Water Window Imaging X-ray Microscopy which is currently being developed by a consortium from the Marshall Space Flight Center, the University of Alabama at Birmingham, Baker Consulting, the Lawrence Livermore National Laboratory, and Stanford University. The high quality solar images achieved during the Stanford/MSFC/LLNL Rocket X-ray Spectroheliograph flight conclusively established that excellent imaging could be obtained with doubly reflecting multilayer optical systems. Theoretical studies carried out as part of the MSFC X-ray Microscopy Program, demonstrated that high quality, high resolution multilayer x-ray imaging microscopes could be achieved with spherical optics in the Schwarzschild configuration and with Aspherical optical systems. Advanced Flow Polishing methods have been used to fabricate substrates for multilayer optics. On hemlite grade Sapphire, the authors have achieved microscopy mirror substrates on concave and convex spherical surfaces with 0.5 Angstrom rms surface smoothness, as measured by the Zygo profilometer. In this paper the authors report on the current status of fabrication and testing of the optical and mechanical subsystems for the Water Window Imaging X-ray Microscope

  2. Quality of dry chemistry testing.

    Science.gov (United States)

    Nakamura, H; Tatsumi, N

    1999-01-01

    Since the development of the qualitative test paper for urine in 1950s, several kinds of dry-state-reagents and their automated analyzers have been developed. "Dry chemistry" has become to be called since the report on the development of quantitative test paper for serum bilirubin with reflectometer in the end of 1960s and dry chemistry has been world widely known since the presentation on the development of multilayer film reagent for serum biochemical analytes by Eastman Kodak Co at the 10th IFCC Meeting in the end of 1970s. We have reported test menu, results in external quality assessment, merits and demerits, and the future possibilities of dry chemistry.

  3. Compact X-ray source at STF (Super Conducting Accelerator Test Facility)

    International Nuclear Information System (INIS)

    Urakawa, J

    2012-01-01

    KEK-STF is a super conducting linear accelerator test facility for developing accelerator technologies for the ILC (International Linear Collider). We are supported in developing advanced accelerator technologies using STF by Japanese Ministry (MEXT) for Compact high brightness X-ray source development. Since we are required to demonstrate the generation of high brightness X-ray based on inverse Compton scattering using super conducting linear accelerator and laser storage cavity technologies by October of next year (2012), the design has been fixed and the installation of accelerator components is under way. The necessary technology developments and the planned experiment are explained.

  4. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

    Science.gov (United States)

    Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C

    2013-06-01

    Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.

  5. Suggestion for improvement of PET quality control tests in Brazil

    International Nuclear Information System (INIS)

    Ferreira, Fernanda C.L.; Magalhaes, Cinthia M.S.; Souza, Divanizia N.

    2009-01-01

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)

  6. Testing the Paradigm that Ultraluminous X-Ray Sources as a Class Represent Accreting Intermediate-Mass Black Holes

    Science.gov (United States)

    Berghea, C. T.; Weaver, K. A.; Colbert, E. J. M.; Roberts, T. P.

    2008-11-01

    To test the idea that ultraluminous X-ray sources (ULXs) in external galaxies represent a class of accreting intermediate-mass black holes (IMBHs), we have undertaken a program to identify ULXs and a lower luminosity X-ray comparison sample with the highest quality data in the Chandra archive. We establish as a general property of ULXs that the most X-ray-luminous objects possess the flattest X-ray spectra (in the Chandra bandpass). No prior sample studies have established the general hardening of ULX spectra with luminosity. This hardening occurs at the highest luminosities (absorbed luminosity >=5 × 1039 erg s-1) and is in line with recent models arguing that ULXs are actually stellar mass black holes. From spectral modeling, we show that the evidence originally taken to mean that ULXs are IMBHs—i.e., the "simple IMBH model"—is nowhere near as compelling when a large sample of ULXs is looked at properly. During the last couple of years, XMM-Newton spectroscopy of ULXs has to a large extent begun to negate the simple IMBH model based on fewer objects. We confirm and expand these results, which validates the XMM-Newton work in a broader sense with independent X-ray data. We find that (1) cool-disk components are present with roughly equal probability and total flux fraction for any given ULX, regardless of luminosity, and (2) cool-disk components extend below the standard ULX luminosity cutoff of 1039 erg s-1, down to our sample limit of 1038.3 erg s-1. The fact that cool-disk components are not correlated with luminosity damages the argument that cool disks indicate IMBHs in ULXs, for which strong statistical support was never found.

  7. DOE standard: Quality assurance inspection and testing of HEPA filters

    International Nuclear Information System (INIS)

    1999-02-01

    This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by US Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The standard specifies HEPA filter quality assurance inspection and testing practices established in DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of written operating procedures for primary FTF functions

  8. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  9. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  10. V/V(max) test applied to SMM gamma-ray bursts

    Science.gov (United States)

    Matz, S. M.; Higdon, J. C.; Share, G. H.; Messina, D. C.; Iadicicco, A.

    1992-01-01

    We have applied the V/V(max) test to candidate gamma-ray bursts detected by the Gamma-Ray Spectrometer (GRS) aboard the SMM satellite to examine quantitatively the uniformity of the burst source population. For a sample of 132 candidate bursts identified in the GRS data by an automated search using a single uniform trigger criterion we find average V/V(max) = 0.40 +/- 0.025. This value is significantly different from 0.5, the average for a uniform distribution in space of the parent population of burst sources; however, the shape of the observed distribution of V/V(max) is unusual and our result conflicts with previous measurements. For these reasons we can currently draw no firm conclusion about the distribution of burst sources.

  11. Pharmacists performing quality spirometry testing: an evidence based review.

    Science.gov (United States)

    Cawley, Michael J; Warning, William J

    2015-10-01

    The scope of pharmacist services for patients with pulmonary disease has primarily focused on drug related outcomes; however pharmacists have the ability to broaden the scope of clinical services by performing diagnostic testing including quality spirometry testing. Studies have demonstrated that pharmacists can perform quality spirometry testing based upon international guidelines. The primary aim of this review was to assess the published evidence of pharmacists performing quality spirometry testing based upon American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines. In order to accomplish this, the description of evidence and type of outcome from these services were reviewed. A literature search was conducted using five databases [PubMed (1946-January 2015), International Pharmaceutical Abstracts (1970 to January 2015), Cumulative Index of Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews] with search terms including pharmacy, spirometry, pulmonary function, asthma or COPD was conducted. Searches were limited to publications in English and reported in humans. In addition, Uniform Resource Locators and Google Scholar searches were implemented to include any additional supplemental information. Eight studies (six prospective multi-center trials, two retrospective single center studies) were included. Pharmacists in all studies received specialized training in performing spirometry testing. Of the eight studies meeting inclusion and exclusion criteria, 8 (100%) demonstrated acceptable repeatability of spirometry testing based upon standards set by the ATS/ERS guidelines. Acceptable repeatability of seven studies ranged from 70 to 99% consistent with published data. Available evidence suggests that quality spirometry testing can be performed by pharmacists. More prospective studies are needed to add to the current evidence of quality spirometry testing performed by

  12. Region III involvement in quality control and quality assurance of radon testing methods

    International Nuclear Information System (INIS)

    Coyle, F.T.

    1990-01-01

    Region III has set a goal of increasing the testing for radon by our residents. One approach to this goal, is to bolster the public's confidence in the testing laboratories. We believe that this can be done most effectively by assuring the quality of the measurements available to the public. All Proficient Laboratories and Pennsylvania Certified Laboratories have submitted a quality assurance (QA) program. A QA audit checklist has been developed which will be finalized and made available to the states in our Region. This paper deals with inspection, verification, and documentation of the various laboratories and their compliance with prudent measuring protocols and addresses the following items: Organization and responsibilities; Sampling procedures; Detector chain of custody; Measurement procedures, quality control checks; State certification and RMP; Data resection, validation, and reporting; Quality assurance reports to management; Interview and discussion of QA audit with responsible officer

  13. Development of a quality management system for borehole investigations. (1) Quality assurance and quality control methodology for hydraulic packer testing

    International Nuclear Information System (INIS)

    Takeuchi, Shinji; Kunimaru, Takanori; Ota, Kunio; Frieg, Bernd

    2011-01-01

    A quality assurance and quality control (QA/QC) system for the hydraulic packer tests has been established based on the surface-based investigations at JAEA's underground research laboratories in Mizunami and Horonobe. The established QA/QC system covers field investigations (data acquisition) and data analysis. For the field investigations, the adopted procedure is selection of a test section based on a detail fluid logging and checking with tally list, followed by inspection of test tools such as pressure transducers and shut-in valves, etc., test method selection using a 'sequential hydraulic test' for deciding appropriate method, and finally data quality confirmation by pressure changes and derivatives on a log-log plots during testing. Test event logs should also be described during testing for traceability. For the test data analysis, a quick analysis for rough estimation of hydraulic parameters, and a detailed analysis using type curve and/or numerical analyses are conducted stepwise. The established QA/QC system has been applied to the recent borehole investigations and its efficiency has been confirmed. (author)

  14. Design and fabrication of multigrid X-ray collimators. [For airborne x-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Acton, L W; Joki, E G; Salmon, R J [Lockheed Missiles and Space Co., Palo Alto, Calif. (USA). Lockheed Palo Alto Research Lab.

    1976-08-01

    Multigrid X-ray collimators continue to find wide application in space research. This paper treats the principles of their design and fabrication and summarizes the experience obtained in making and flying thirteen such collimators ranging in angular resolution from 10 to 0.7 arc min FWHM. Included is a summary of a survey of scientist-users and industrial producers of collimator grids regarding grid materials, precision, plating, hole quality and results of acceptance testing.

  15. Spectra transmitted by mortar barite in X-Ray qualities applied in diagnostic radiology as shielding

    Energy Technology Data Exchange (ETDEWEB)

    Almeida Junior, Airton T., E-mail: airton.almeida@fundacentro.gov.br [Fundacaoo Jorge Duprat Figueiredo de Seguranca e Medicina do Trabalho (FUNDACENTRO), Belo Horizonte, MG (Brazil); Araujo, F.G.S. [Universidade Federal de Ouro Preto (REDEMAT/UFOP), MG (Brazil); Nogueira, M.S., E-mail: mnogue@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Santos, M.A.P. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2015-07-01

    Concrete which contains water, cement and aggregate, is widely used in building construction such as medical hospitals. The CdZnTe spectrometry system was used to acquire the transmitted spectra in the RQR qualities and the stripping procedure was performed by taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined. The samples were prepared in rectangular plate format with dimensions of (5 x 5) cm with thicknesses varying from 0.2cm to 2cm and exposed to x-ray beams generated. The HVL and the mean energy in this energy range was determined. (author)

  16. Web-based X-ray quality control documentation.

    Science.gov (United States)

    David, George; Burnett, Lou Ann; Schenkel, Robert

    2003-01-01

    The department of radiology at the Medical College of Georgia Hospital and Clinics has developed an equipment quality control web site. Our goal is to provide immediate access to virtually all medical physics survey data. The web site is designed to assist equipment engineers, department management and technologists. By improving communications and access to equipment documentation, we believe productivity is enhanced. The creation of the quality control web site was accomplished in three distinct steps. First, survey data had to be placed in a computer format. The second step was to convert these various computer files to a format supported by commercial web browsers. Third, a comprehensive home page had to be designed to provide convenient access to the multitude of surveys done in the various x-ray rooms. Because we had spent years previously fine-tuning the computerization of the medical physics quality control program, most survey documentation was already in spreadsheet or database format. A major technical decision was the method of conversion of survey spreadsheet and database files into documentation appropriate for the web. After an unsatisfactory experience with a HyperText Markup Language (HTML) converter (packaged with spreadsheet and database software), we tried creating Portable Document Format (PDF) files using Adobe Acrobat software. This process preserves the original formatting of the document and takes no longer than conventional printing; therefore, it has been very successful. Although the PDF file generated by Adobe Acrobat is a proprietary format, it can be displayed through a conventional web browser using the freely distributed Adobe Acrobat Reader program that is available for virtually all platforms. Once a user installs the software, it is automatically invoked by the web browser whenever the user follows a link to a file with a PDF extension. Although no confidential patient information is available on the web site, our legal

  17. Performance of X-ray equipment used for conventional radiographic examinations of children

    International Nuclear Information System (INIS)

    Lacerda, Marco A.S.; Silva, Teogenes A. da; Khoury, Helen J.

    2009-01-01

    The performance of X-ray equipment that are used for conventional X-ray examinations of children in four hospitals of Belo Horizonte, Brazil, was evaluated. The methodology proposed by the Brazilian authority for radiation protection in diagnostic radiology was adopted. The performance tests were carried out in six X-ray machines and they consisted of measurements and determination of the X-ray tube output, linearity and constancy of radiation output, accuracy and reproducibility of the exposure time and tube potential, half-value layer (HVL), light field / X-ray field alignment and accuracy of the X-ray field indicator. It was observed that only one hospital had the suitable equipment for X-ray examinations of children. Results showed that all six equipment of the four hospitals presented unsatisfactory performance in some quality control tests. Only for some combinations of the exposure parameters, generally employed in pediatric X-ray examinations, some equipment complied with the authority requirements. (author)

  18. Compliance testing of medical diagnostic x-ray equipment: three years experience of a public hospital in western Australia

    International Nuclear Information System (INIS)

    Tuchyna, T.; Jacob, C.S.

    2000-01-01

    Full text: A formal compliance testing program which began on 1 January 1997 called for all medical and diagnostic x-ray equipment to be tested according to protocols established by the Western Australian Radiological Council. This work describes the impact of the legislation three years post implementation on a major teaching Hospital with 45 x-ray tubes located throughout 37 rooms. Testing is performed prior to scheduled service by licensed compliance testers according to test methods specified in the Western Australian Compliance Testing Workbook, 1997. A dedicated non-invasive x-ray beam analyser is instrumental in accurately determining radiation output parameters of the generator and x-ray tube. Assessment of compliance is determined by a Qualified Expert. Repair and re-testing of non-compliant items is coordinated with service personnel. Notices of non-compliance were received for approximately 60% of the equipment in the Hospital following the equipment' first annual test. Reasons and seriousness of failure varied according to equipment category, test category, equipment use and age. The majority of non-compliance issues were resolved within 90 days. At the end of the third year of testing, approximately 75% of the x-ray units tested met the compliance criteria. The main reasons for non-compliance were found to be design limitations associated with old technology and the current radiation legislation that makes it difficult for older equipment to meet the stringent criteria. The number and categories of failure did not significantly decrease in the second or third years of testing. Exemptions from compliance criteria have been sought for two units on the basis of age and design. Units unable to meet the criteria following several repair attempts or where the cost of repair was deemed not justified, were decommissioned. Formal testing of medical x-ray equipment has demonstrated various non-compliance issues that did not significantly improve during the

  19. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Science.gov (United States)

    Guimarães, M. C.; Silva, C. R. E.; Rosado, P. H. G.; Cunha, P. G.; Da Silva, T. A.

    2018-03-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work.

  20. Quality engineering in FFTF irradiation tests

    International Nuclear Information System (INIS)

    Caplinger, W.H.

    1980-01-01

    The design and fabrication of an irradiation test for the Fast Flux Test Facility are planned, controlled and documented in accordance with the Department of Energy standards. Tests built by Westinghouse Hanford Company are further controlled and guided by a series of increasingly specific documents, including guidelines for program control, procedures for engineering operations, standard practices and detailed operating procedures. In response to this guidance, a series of five documents is prepared covering each step of the experiment from conception through fabrication and assembly. This paper describes the quality assurance accompanying these five steps

  1. Photoelectron and x-ray holography by contrast: enhancing image quality and dimensionality

    Energy Technology Data Exchange (ETDEWEB)

    Fadley, C.S.; Zhao, L. [Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Department of Physics, University of California, Davis, CA (United States); Hove, M.A. van [Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Department of Physics, University of California, Davis, CA (United States); Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Kaduwela, A.; Marchesini, S. [Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Omori, S. [Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Institute of Industrial Science, University of Tokyo, Tokyo (Japan); Sony Corporation Semiconductor Network Company, Asahi-cho, Atsugi, Kanagawa (Japan)

    2001-11-26

    Three forms of electron or x-ray holography 'by contrast' are discussed: they all exploit small changes in diffraction conditions to improve image quality and/or extract additional information. Spin-polarized photoelectron holography subtracts spin-down from spin-up holograms so as to image the relative orientations of atomic magnetic moments around an emitter atom. Differential photoelectron holography subtracts holograms taken at slightly different energies so as to overcome the forward-scattering problem that normally degrades the three-dimensional imaging of atoms, particularly for emitter atoms that are part of a bulk substrate environment. Resonant x-ray fluorescence holography also subtracts holograms at slightly different energies, these being chosen above and below an absorption edge of a constituent atom, thus allowing the selective imaging of that type of atom, or what has been referred to as imaging 'in true colour'. (author)

  2. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    International Nuclear Information System (INIS)

    Murata, C.H.; Fernandes, D.C.; Lavínia, N.C.; Caldas, L.V.E; Pires, S.R; Medeiros, R.B.

    2014-01-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  3. Characterization of a test device for determination of the half value layer and of filtration with quality equity of materials in accordance with standard ABNT NBR IEC 60601-1-3

    International Nuclear Information System (INIS)

    Viana, Vlamir

    2012-01-01

    The motivation of this work was the development and validation of a device to perform the tests established by ABNT NBR IEC 60601-1-3 versions published in 2001 and 2011. The purpose of the tests is to determine the half-value layer – HVL and filtration with equivalent filtration quality in mmAl, materials that intercept the X-ray beam from their emission to the X-ray image receiving device. This filtration includes all the materials present in radiation source assembly, formed by the x-ray tube housing with x-ray tube inserted, the collimator (inherent filtration) and by materials present in the patients support, as Table and wall bucky, both incorporate image receiving device which is also evaluated. In the development was taken in consideration the routine of tests execution routine, in order to reduce the operator interaction with the system and in order to reduce the human factor in the execution, reflecting directly on the measurement uncertainty, in the runtime reduction of the runtime and radiation safety. The device was validated with respect to: a) Effect of positioning and distribution of the filters in the filter changer device; b) Influence of purity of the aluminum filter used in the device, and c) Comparison tests carried out with the testing device with respect to the tests carried out with a reference X-ray generator. (author)

  4. Quality Assurance for Radiographic Imaging (Military Corps Hospitals in Khartoum State) in Sudan

    International Nuclear Information System (INIS)

    Mohamad, M. Y.

    2007-01-01

    The purpose of this study is to evaluate the Quality Assurance procedures in the Military Corps in Khartoum state, through the comprehensive Quality Control QC procedures of the x-ray machines and darkrooms in the x-ray departments, and to provide a Quality Assurance Manual to support the federal ministry of Health running QA program. This study is the first time that the departments of the Military Corps apply QC tests on their x-ray machines. The total number of x-ray machines in Khartoum state is 10 machines with 4 darkrooms. Only three of the x-ray machines are tested and the results showed that there are unacceptable parameters of the major exposure factors which determine the image quality. The percentage of accuracy defects are 67% for kVp Accuracy, 67% for Time Accuracy, 33% for Relative mA Linearity, 33% for Relative mAs Linearity, 67% for kVp Reproducibility, 67% for Collimator test. Also the tested darkrooms showed that the percentage of unacceptable parameters as: 15% for tested intensifying screens, 18% for tested Cassettes, 100% for light leakage, 67% for Safelight. Reject film Analysis showed that 5.3% and 10% is the reject percentage during four months for the main and casualty centers respectively. Personal monitoring records showed that the dose is within the dose limits the maximum and minimum Dose equivalent in 2001 is 4.231 Sv, 0.154 Sv and in 2002 is 2.736 Sv, 0.167 Sv consequently, and the monitoring has been stopped since July 2002. Also the study reveals that only 4% from the total cost of the x-ray machines owned by the mentioned hospitals is the price of the QC test tools equipments. The study gives a review of all definitions and QC procedures needed for the QA manual and can be referenced as a QA Manual for the Military Corps or any other hospital.

  5. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Rosado, P.H.G.; Cunha, P.G. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  6. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    International Nuclear Information System (INIS)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da; Rosado, P.H.G.; Cunha, P.G.

    2017-01-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  7. Approaches to quality management and accreditation in a genetic testing laboratory

    Science.gov (United States)

    Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth

    2010-01-01

    Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559

  8. Quality assurance of radiopharmaceuticals-specifications and test procedures

    International Nuclear Information System (INIS)

    Baldas, J.; Bonnyman, J.; Pojer, P.M.

    1981-08-01

    This report is a compilation of test methods used and specifications adopted for the Radiopharmaceutical Quality Assurance Test Programme conducted by the Australian Radiation Laboratory. In some cases test procedures described have been taken from various Pharmacopoeias or methods published in the literature. In other cases test methods have been developed at the ARL

  9. The Study on the Attenuation of X-ray and Imaging Quality by Contents in Stomach

    International Nuclear Information System (INIS)

    Dong, Kyung Rae; Ji, Youn Sang; Kim, Chang Bok; Choi, Seong Kwan; Moon, Sang In; Dieter, Kevin

    2009-01-01

    This study examined the change in the attenuation of X-rays with the ROI (Region of Interest) in DR (Digital Radiography) according to the stomach contents by manufacturing a tissue equivalent material phantom to simulate real stomach tissue based on the assumption that there is some attenuation of X-rays and a difference in imaging quality according to the stomach contents. The transit dosage by the attenuation of X-rays decreased with increasing protein thickness, which altered the average ROI values in the film and DR images. A comparison of the change in average ROI values of the film and DR image showed that the image in film caused larger density changes with varying thickness of protein than the image by DR. The results indicate that NPO (nothing by mouth) is more important in film system than in DR system.

  10. The Study on the Attenuation of X-ray and Imaging Quality by Contents in Stomach

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kyung Rae; Ji, Youn Sang; Kim, Chang Bok; Choi, Seong Kwan; Moon, Sang In [Dept. of Radiological Technology, Gwangju Health College University, Gwangju (Korea, Republic of); Dieter, Kevin [Dept. of Physical Therapy, Gwangju Health College University, Gwangju (Korea, Republic of)

    2009-03-15

    This study examined the change in the attenuation of X-rays with the ROI (Region of Interest) in DR (Digital Radiography) according to the stomach contents by manufacturing a tissue equivalent material phantom to simulate real stomach tissue based on the assumption that there is some attenuation of X-rays and a difference in imaging quality according to the stomach contents. The transit dosage by the attenuation of X-rays decreased with increasing protein thickness, which altered the average ROI values in the film and DR images. A comparison of the change in average ROI values of the film and DR image showed that the image in film caused larger density changes with varying thickness of protein than the image by DR. The results indicate that NPO (nothing by mouth) is more important in film system than in DR system.

  11. Comparative study of the Quality Control of x-ray tubes and generators in hospital assistance and primary assistance in Galician autonomous community

    International Nuclear Information System (INIS)

    Pombar Camean, M.; Lobato Busto, R.

    1992-01-01

    The quality guarantee in Diagnostic Radiology is defined as the organized effort of surgical staff to guarantee sufficient quality images, which provide the correct diagnostic information, as cheaply as possible and with the least exposure to radiation for the patient. In this paper a comparative study about the quality control of x-ray tube and generators in hospital assistance and primary assistance is present. In the conclusions, it is confirmed that the antiquity and poor conservation of the primary attendance x-ray equipment, have influence on the studied constants and therefore, influence the doses received by the patients. (author)

  12. Evaluation of the conditions of operation of X-ray equipment as regards the coincidence between light field, radiation field and the central ray alignment in radiology services of the Recife, Brazil

    International Nuclear Information System (INIS)

    Oliveira, Claudia F.M.; Silva, Iran J.O.; Lopes Filho, Ferdinand J.; Morais, Carolinne S.; Junior, Claudio L.R.

    2014-01-01

    This paper aims at considering the need for constant evaluation of diagnostic radiology equipment and the fact that this issue be part of the radiology technologist's tasks, develop skills in radiology technologist through applying quality control tests, as regards the assessment of coincidence between the light field and the radiation field and the alignment of the radiation beam of medical X-ray equipment in radiology services in the city of Recife. For the tests, the procedures by national protocols of Quality Control Tests were adopted - QCT and the Medical Radiodiagnosis Manual. The instruments used to check the alignment of the central ray was an acrylic cylinder with steel balls of 0.8 mm diameter located in the upper and lower base separated by a distance of 15 cm, a chassis loaded with film, tape and level bubble. The results show that the tested devices are in good condition for diagnostic radiology, with regard to both the radiation field to be exposed as well as the image quality for a more accurate diagnosis, which guarantees the individual radiological protection

  13. Comparative analysis of partial imaging performance parameters of home and imported X-ray machines

    International Nuclear Information System (INIS)

    Cao Yunxi; Wang Xianyun; Liu Huiqin; Guo Yongxin

    2002-01-01

    Objective: To compare and analyze the performance indexes and the imaging quality of the home and imported X-ray machines through testing their partial imaging performance parameters. Methods: By separate sampling from 10 home and 10 imported X-ray machines, the parameters including tube current, time of exposure, machine total exposure, and repeatability were tested, and the imaging performance was evaluated according to the national standard. Results: All the performance indexes met the standard of GB4505-84. The first sampling tests showed the maximum changing coefficient of imaging performance repeatability of the home X-ray machines was Δmax1 = 0.025, while that of the imported X-ray machine was Δmax1 = 0.016. In the second sampling tests, the maximum changing coefficients of the two were Δmax2 = 0.048 and Δmax2 = 0.022, respectively. Conclusion: The 2 years' follow-up tests indicate that there is no significant difference between the above-mentioned parameters of the elaborately adjusted home X-ray machines and imported ones, but the home X-ray machines are no better than the imported X-ray machines in stability and consistency

  14. Quality assurance in the nuclear test program

    International Nuclear Information System (INIS)

    Shearer, J.N.

    1979-01-01

    In February 1979 Test Program laid the ground work for a new quality assurance structure. The new approach was based on the findings and recommendations of the Ad Hoc QA Program Review panel, which are summarized in this report. The new structure places the responsibility for quality assurance in the hands of the line organizations, both in the programmatic and functional elements of the LLL matrix

  15. Image quality and dose in mammographic images obtained in Mexico City hospitals

    International Nuclear Information System (INIS)

    Ruiz-Trejo, C.; Brandan, M.-E.; Verdejo, M.; Flores, A.; Guevara, M.; Martin, J.; Madero-Preciado, L.

    2001-01-01

    The performance of three mammographic systems in large Mexican hospitals has been evaluated, as well as the image quality and associated dose. Quality control tests include examination of X-ray equipment, darkroom conditions, film processor, and viewboxes. Systems referred to as '1', '2', and '3' passed 50%, 75% and 75% of these tests, respectively. Quality image is assessed using five images obtained under similar nominal conditions in each X-ray equipment. System 1 generates no image of acceptable quality, while equipment 2 and 3 produce one and two, respectively. The mean glandular dose for the best images obtained in each service with an accreditation phantom has been measured, and the values are 1.4 mGy, 1.6 mGy, and 1.0 mGy, respectively. (author)

  16. New test of Lorentz symmetry using ultrahigh-energy cosmic rays

    Science.gov (United States)

    Anchordoqui, Luis A.; Soriano, Jorge F.

    2018-02-01

    We propose an innovative test of Lorentz symmetry by observing pairs of simultaneous parallel extensive air showers produced by the fragments of ultrahigh-energy cosmic ray nuclei which disintegrated in collisions with solar photons. We show that the search for a cross-correlation of showers in arrival time and direction becomes background free for an angular scale ≲3 ° and a time window O (10 s ) . We also show that if the solar photo-disintegration probability of helium is O (10-5.5) then the hunt for spatiotemporal coincident showers could be within range of existing cosmic ray facilities, such as the Pierre Auger Observatory. We demonstrate that the actual observation of a few events can be used to constrain Lorentz violating dispersion relations of the nucleon.

  17. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  18. The "Air in the CT X-ray Tube Oil" Artifact-Examples of the Quality Control Images and the Evaluation of Four Potential Clinical Patients' Head Computed Tomography Cases.

    Science.gov (United States)

    Törmänen, Juhani; Rautiainen, Jari; Tahvonen, Pirita; Leinonen, Kimmo; Nieminen, Miika T; Tervonen, Osmo

    We present a newly reposted scanner-based artifact-with 4 potential patients' head computed tomography (CT) cases-the "Air in the CT X-ray Tube Oil" artifact with a 64-slice multidetector CT. This artifact mimics diseases, which cause hypodense findings in CT images. It can be difficult to notice in the clinical patient imaging but can be also very difficult to verify in quality control tests.

  19. Effects of X-ray irradiation on the microbial growth and quality of flue-cured tobacco during aging

    International Nuclear Information System (INIS)

    Wang, J.J.; Xu, Z.C.; Fan, J.L.; Wang, Y.; Tian, Z.J.; Chen, Y.T.

    2015-01-01

    X-ray irradiation was evaluated for improving microbial safety and the quality of flue-cured tobacco during aging. Tobacco samples were irradiated at doses of 0, 1, 2, 3 and 5 kGy and stored for 12 months under normal storage conditions or in a high-humidity (RH>70%) room. Microbiological data indicated that the population of total aerobic bacteria was significantly decreased with increasing irradiation doses. In particular, a dose of 2 kGy was effective for the decontamination of fungi from the tested samples, with a 0.93 log CFU/g reduction for bacteria. The control and 1 kGy X-ray treated tobacco samples were became rotted and moldy after the 12th month, whereas those treated with 2, 3 and 5 kGy had no detectable mold during 12 months of storage at high humidity. Chemical measurements showed that irradiation up to 3 kGy did not affect the total nitrogen, nicotine, reducing and total sugars, ratio of total nitrogen to nicotine and sugar-to-nicotine ratio. Furthermore, sensory evaluation results also showed that X-ray irradiation did not affect sensory scores with irradiation at a dose <3 kGy. Based on these results, X-ray irradiation dose in the range of 2–3 kGy is recommended for the decontamination of fungi from flue-cured tobacco. - Highlights: • 2 kGy dose improved sufficiently the microbial safety of flue-cured tobacco. • The doses up to 3 kGy did not affect the chemical components. • A dose <3 kGy had no effect on sensory scores. • The recommended dose to irradiated flue-cured tobacco is the range of 2–3 kGy

  20. Deviation Value for Conventional X-ray in Hospitals in South Sulawesi Province from 2014 to 2016

    Science.gov (United States)

    Bachtiar, Ilham; Abdullah, Bualkar; Tahir, Dahlan

    2018-03-01

    This paper describes the conventional X-ray machine parameters tested in the region of South Sulawesi from 2014 to 2016. The objective of this research is to know deviation of every parameter of conventional X-ray machine. The testing parameters were analyzed by using quantitative methods with participatory observational approach. Data collection was performed by testing the output of conventional X-ray plane using non-invasive x-ray multimeter. The test parameters include tube voltage (kV) accuracy, radiation output linearity, reproducibility and radiation beam value (HVL) quality. The results of the analysis show four conventional X-ray test parameters have varying deviation spans, where the tube voltage (kV) accuracy has an average value of 4.12%, the average radiation output linearity is 4.47% of the average reproducibility of 0.62% and the averaged of the radiation beam (HVL) is 3.00 mm.

  1. Modern instrumentation for radiation introscopic testing of welding quality

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1985-01-01

    Modern instrumenlation used for radiation introscopy of welded joints is discussed. the absolute (relative) sensitivity of radiation testing, resolution range, efficiency are considered as basic parameters of introscopes. The characteristics of fluoroscopes, radiation-television installations with the external scintillator and radiative image converter as well as with X-ray vidicons are given. The characterisitcs of radiation introscopes with manipulators to move objects being tested are analysed as well as digitized radiation introscopes

  2. DISCRETIZATION APPROACH USING RAY-TESTING MODEL IN PARTING LINE AND PARTING SURFACE GENERATION

    Institute of Scientific and Technical Information of China (English)

    HAN Jianwen; JIAN Bin; YAN Guangrong; LEI Yi

    2007-01-01

    Surface classification, 3D parting line, parting surface generation and demoldability analysis which is helpful to select optimal parting direction and optimal parting line are involved in automatic cavity design based on the ray-testing model. A new ray-testing approach is presented to classify the part surfaces to core/cavity surfaces and undercut surfaces by automatic identifying the visibility of surfaces. A simple, direct and efficient algorithm to identify surface visibility is developed. The algorithm is robust and adapted to rather complicated geometry, so it is valuable in computer-aided mold design systems. To validate the efficiency of the approach, an experimental program is implemented. Case studies show that the approach is practical and valuable in automatic parting line and parting surface generation.

  3. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  4. WE-D-BRA-07: Analysis of ArcCHECK Diode Array Performance for ViewRay Quality Assurance

    International Nuclear Information System (INIS)

    Ellefson, S; Culberson, W; Bednarz, B; DeWerd, L; Bayouth, J

    2015-01-01

    Purpose: Discrepancies in absolute dose values have been detected between the ViewRay treatment planning system and ArcCHECK readings when performing delivery quality assurance on the ViewRay system with the ArcCHECK-MR diode array (SunNuclear Corporation). In this work, we investigate whether these discrepancies are due to errors in the ViewRay planning and/or delivery system or due to errors in the ArcCHECK’s readings. Methods: Gamma analysis was performed on 19 ViewRay patient plans using the ArcCHECK. Frequency analysis on the dose differences was performed. To investigate whether discrepancies were due to measurement or delivery error, 10 diodes in low-gradient dose regions were chosen to compare with ion chamber measurements in a PMMA phantom with the same size and shape as the ArcCHECK, provided by SunNuclear. The diodes chosen all had significant discrepancies in absolute dose values compared to the ViewRay TPS. Absolute doses to PMMA were compared between the ViewRay TPS calculations, ArcCHECK measurements, and measurements in the PMMA phantom. Results: Three of the 19 patient plans had 3%/3mm gamma passing rates less than 95%, and ten of the 19 plans had 2%/2mm passing rates less than 95%. Frequency analysis implied a non-random error process. Out of the 10 diode locations measured, ion chamber measurements were all within 2.2% error relative to the TPS and had a mean error of 1.2%. ArcCHECK measurements ranged from 4.5% to over 15% error relative to the TPS and had a mean error of 8.0%. Conclusion: The ArcCHECK performs well for quality assurance on the ViewRay under most circumstances. However, under certain conditions the absolute dose readings are significantly higher compared to the planned doses. As the ion chamber measurements consistently agree with the TPS, it can be concluded that the discrepancies are due to ArcCHECK measurement error and not TPS or delivery system error. This work was funded by the Bhudatt Paliwal Professorship and the

  5. A survey in Portuguese X-ray fluoroscopy equipment: dose rates and image quality

    International Nuclear Information System (INIS)

    Teixeira, Nuno G.; Cunha, Gilda R.; Coutinho, Guilherme M.; Trindade, Hugo R.; Carvoeiras, Pedro P.

    2015-01-01

    X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level. (authors)

  6. Spinal cord testing: auditing for quality assurance.

    Science.gov (United States)

    Marr, J A; Reid, B

    1991-04-01

    A quality assurance audit of spinal cord testing as documented by staff nurses was carried out. Twenty-five patient records were examined for accuracy of documented testing and compared to assessments performed by three investigators. A pilot study established interrater reliability of a tool that was designed especially for this study. Results indicated staff nurses failed to meet pre-established 100% standard in all categories of testing when compared with investigator's findings. Possible reasons for this disparity are discussed as well as indications for modifications in the spinal testing record, teaching program and preset standards.

  7. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group (WG 10) to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray installations. Since then, the working group has produced a report on General Aspects of Quality Assurance in Diagnostic X-ray Departments and four draft standards on specific topics, while seven more documents are in advanced drafting stage. Several others are presently under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform the tests and interpret their results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standard produced so far, with emphasis on the physical parameters of diagnostic X-ray installations and their proposed criteria for satisfactory performance. (author)

  8. A method to test the performance of an energy-dispersive X-ray spectrometer (EDS).

    Science.gov (United States)

    Hodoroaba, Vasile-Dan; Procop, Mathias

    2014-10-01

    A test material for routine performance evaluation of energy-dispersive X-ray spectrometers (EDS) is presented. It consists of a synthetic, thick coating of C, Al, Mn, Cu, and Zr, in an elemental composition that provides interference-free characteristic X-ray lines of similar intensities at 10 kV scanning electron microscope voltage. The EDS energy resolution at the C-K, Mn-Lα, Cu-Lα, Al-K, Zr-Lα, and Mn-Kα lines, the calibration state of the energy scale, and the Mn-Lα/Mn-Kα intensity ratio as a measure for the low-energy detection efficiency are calculated by a dedicated software package from the 10 kV spectrum. Measurements at various input count rates and processor shaping times enable an estimation of the operation conditions for which the X-ray spectrum is not yet corrupted by pile-up events. Representative examples of EDS systems characterized with the test material and the related software are presented and discussed.

  9. Construction and Test of Low Cost X-Ray Tomography Scanner for Physical-Chemical Analysis and Nondestructive Inspections

    International Nuclear Information System (INIS)

    Oliveira, Jose Martins Jr. de; Martins, Antonio Cesar Germano

    2009-01-01

    X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function-MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device.

  10. Standard test methods for chemical analysis of ceramic whiteware materials using wavelength dispersive X-Ray fluorescence spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 These test methods cover the determination of ten major elements (SiO2, Al2O3, Fe2O3, MgO, CaO, Na2O, K2O, TiO2, P2O5, MnO, and LOI in ceramic whitewares clays and minerals using wavelength dispersive X-ray fluorescence spectrometry (WDXRF). The sample is first ignited, then fused with lithium tetraborate and the resultant glass disc is introduced into a wavelength dispersive X-ray spectrometer. The disc is irradiated with X-rays from an X-ray tube. X-ray photons emitted by the elements in the samples are counted and concentrations determined using previously prepared calibration standards. (1) In addition to 10 major elements, the method provides a gravimetric loss-on-ignition. Note 1—Much of the text of this test method is derived directly from Major element analysis by wavelength dispersive X-ray fluorescence spectrometry, included in Ref (1). 1.2 Interferences, with analysis by WDXRF, may result from mineralogical or other structural effects, line overlaps, and matrix effects. The structure of the...

  11. Development of quality assurance programme for prescribed ionizing radiation source testing. Recommendations

    International Nuclear Information System (INIS)

    1999-01-01

    The document gives guidance to those applying for licence to perform ionizing radiation source acceptance tests and long-term stability tests and provides information which should be known when introducing quality assurance systems in compliance with legislative requirements. It is envisaged that this document ('Recommendations') will form a basis for final Safety Guides to be issued by the State Office for Nuclear Safety, the Czech nuclear regulatory authority. The setup of the publication is as follows. Part I gives a glossary of basic terms in quality systems. Part 2 explains quality system principles, paying special attention to radiation safety issues, and describes the structure and scope of quality system documentation. Part 3 explains the individual elements of the quality system and gives practical examples. Part 4 deals with the quality assurance programme; using instructions and practical examples, this part shows how the quality system elements should be applied to long-time stability testing and acceptance testing. A model structure of 2nd degree documentation (guidelines) and a model testing protocol are given in annexes. (P.A.)

  12. Measurements of X ray absorbed doses to dental patients in two dental X ray units in Nigeria

    International Nuclear Information System (INIS)

    Ogundare, F.O.; Oni, O.M.; Balogun, F.A.

    2002-01-01

    Measurements of absorbed doses from radiographic examinations to various anatomical sites in the head and neck of patients with an average age of 45 years using intra-oral dental radiography have been carried out. LiF (TLD-100) dosemeters were used for the measurements of the absorbed dose. The measured absorbed doses to the various anatomical sites in the two units are reported, discussed and compared with results from the literature. Quality control measurements were also performed using a Victoreen quality control test device on the X ray units. The tube voltage accuracies for the two units were found to be within acceptable limits (less than ±10%). On the other hand the exposure time accuracies for these units have large deviations (>20%). These results and those that have been reported in the literature may be an indication that high patient doses are common in most dental X ray centres and countries. As a result of this, regular compliance and performance checks of dental diagnostic X ray equipment are essential in order to ensure proper performance and to minimise unnecessary patient and operator doses. (author)

  13. A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

    Directory of Open Access Journals (Sweden)

    Jai Wan Cho

    2014-01-01

    Full Text Available We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

  14. Microstructure and micromechanics of the heart urchin test from X-ray tomography

    DEFF Research Database (Denmark)

    Müter, D.; Sørensen, H. O.; Oddershede, Jette

    2015-01-01

    The microstructure of many echinoid species has long fascinated scientists because of its high porosity and outstanding mechanical properties. We have used X-ray microtomography to examine the test of Echinocardium cordatum (heart urchin), a burrowing cousin of the more commonly known sea urchins...

  15. RPC HADES-TOF wall cosmic ray test performance

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, A., E-mail: alberto@coimbra.lip.pt [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Belver, D.; Cabanelas, P. [LabCAF, Universidade de Santiago de Compostela, USC, Santiago de Compostela (Spain); Diaz, J. [Instituto de Fisica Corpuscular IFIC (CSIC-Universidad de Valencia), Valencia (Spain); Fonte, P. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Instituto Superior de Engenharia de Coimbra, ISEC, Coimbra (Portugal); Garzon, J.A. [LabCAF, Universidade de Santiago de Compostela, USC, Santiago de Compostela (Spain); Gil, A. [Instituto de Fisica Corpuscular IFIC (CSIC-Universidad de Valencia), Valencia (Spain); Gonzalez-Diaz, D.; Koenig, W.; Kolb, B. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Lopes, L. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Palka, M. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Pereira, A. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); and others

    2012-01-01

    In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m{sup 2}. All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1% (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.

  16. RPC HADES-TOF wall cosmic ray test performance

    International Nuclear Information System (INIS)

    Blanco, A.; Belver, D.; Cabanelas, P.; Díaz, J.; Fonte, P.; Garzon, J.A.; Gil, A.; Gonzalez-Díaz, D.; Koenig, W.; Kolb, B.; Lopes, L.; Palka, M.; Pereira, A.

    2012-01-01

    In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m 2 . All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1% (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.

  17. European wind turbine testing procedure developments. Task 2: Power quality

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Friis Pedersen, Troels; Gerdes, G.

    2001-01-01

    The present report describes the work done in the power quality subtask of the European Wind Turbine Testing Procedure Developments project funded by the EU SMT program. The objective of the power quality subtask has been to make recommendations andprovide background for new standards...... for measurement and testing of wind turbine power quality. The focus in the work has been to support the ongoing standardisation work in IEC with a new standard IEC61400-21 for measurement and assessment of powerquality characteristics of grid connected wind turbines. The work has also been based on the power...... quality measuremnet procedure in the Measnet cooperation of European test stations for wind turbines. The first working item of the project has been toverify the state of the art of the measurement procedures by analyses and comparisons of the measurements and data processing software of the participating...

  18. Field size and centring for conventional X-ray equipment

    International Nuclear Information System (INIS)

    Klimpel, H.; Kreienfeld, H.; Overbeck, R.

    1989-01-01

    Since 1973, all X-ray equipment for medical applications in the Federal Republic of Germany has had to be examined according to the requirements of the German ''Rontgenverordnung'' before it is used on patients and after each essential modification of design or construction. These examinations are carried out by inspectors appointed by the authorities, e.g. TUV. The field size adjustment and the centring of the radiation beam in relation to the image reception area is checked, along with other tests. To increase quality assurance in X-ray diagnosis, since the mid-1980s X-ray equipment has also been subject to in-service inspections to an increasing extent. (author)

  19. Survey on the parameters influencing X-ray picture quality

    International Nuclear Information System (INIS)

    Stender, H.S.

    1985-01-01

    Survey on factors influencing X-ray picture quality: 1) identification of patient and imaged body part. 2) Object properties - thickness, density, built; spatial expansion and arrangement of anatomical parts; object parts in a homogenic and an inhomogenic environment; object movements. 3) Examination technique - matching to medical issue; positioning and adjustment; projection; picture format in keeping with the medical issue; object-related fade-in; distance ratios; contrast medium distribution or deposition; compression. 4) Technical factors of picture production - radiation quality tube voltage; reproducible mAs and mR/mAs; automatic exposure equipment; focal spot size; scattered radiation grid; image intensifier and indirect radiography system; exposure time, dose-to-exposure-time ratio; film-screen combination; cassette with uniform pressure contact; film processing system; radiation safety and light safety. 5) Physical imaging parameters - mean optical density; resolution capacity; contrast reproduction; noise; modulation transmission function. 6) Perceptible picture properties - luminance density; picture contrast; recognizability of details; impression of grain structure; blurred picture structure; visually conspicuous elements. 7) Requirements on picture viewing - viewing device with high luminance density and equalized illumination; possible modification of brilliance; possible fade-in operations and prevention of ambient glare; spot light with iris diaphragm; possible viewing by magnifying lens; selection of correct viewing distances; repeated picture viewing or evaluation by two or more viewers. (orig./HP) [de

  20. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    Science.gov (United States)

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  1. Quantitative determination of minerals in Nevada Test Site samples by x-ray diffraction

    International Nuclear Information System (INIS)

    Pawloski, G.A.

    1983-07-01

    The external standard intensity ratio technique has been developed into a routine procedure for quantitatively determining mineralogic compositions of Nevada Test Site (NTS) samples by x-ray diffraction. This technique used ratios of x-ray intensity peaks from the same run which eliminates many possible errors. Constants have been determined for each of thirteen minerals commonly found in NTS samples - quartz, montmorillonite, illite, clinoptilolite, cristobalite, feldspars, calcite, dolomite, hornblende, kaolinite, muscovite, biotite, and amorphous glass. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of quartz are used to calculate sample composition. The technique has been tested on samples with three to eleven components representative of geologic environments at NTS, and is accurate to 7.0 wt % of the total sample. The minimum amount of each of these minerals detectable by x-ray diffraction has also been determined. QUANTS is a computer code that calculates mineral contents and produces a report sheet. Constants for minerals in NTS samples other than those listed above can easily be determined, and added to QUANTS at any time

  2. Framework and indicator testing protocol for developing and piloting quality indicators for the UK quality and outcomes framework

    Directory of Open Access Journals (Sweden)

    Burke Martyn

    2011-08-01

    Full Text Available Abstract Background Quality measures should be subjected to a testing protocol before being used in practice using key attributes such as acceptability, feasibility and reliability, as well as identifying issues derived from actual implementation and unintended consequences. We describe the methodologies and results of an indicator testing protocol (ITP using data from proposed quality indicators for the United Kingdom Quality and Outcomes Framework (QOF. Methods The indicator testing protocol involved a multi-step and methodological process: 1 The RAND/UCLA Appropriateness Method, to test clarity and necessity, 2 data extraction from patients' medical records, to test technical feasibility and reliability, 3 diaries, to test workload, 4 cost-effectiveness modelling, and 5 semi-structured interviews, to test acceptability, implementation issues and unintended consequences. Testing was conducted in a sample of representative family practices in England. These methods were combined into an overall recommendation for each tested indicator. Results Using an indicator testing protocol as part of piloting was seen as a valuable way of testing potential indicators in 'real world' settings. Pilot 1 (October 2009-March 2010 involved thirteen indicators across six clinical domains and twelve indicators passed the indicator testing protocol. However, the indicator testing protocol identified a number of implementation issues and unintended consequences that can be rectified or removed prior to national roll out. A palliative care indicator is used as an exemplar of the value of piloting using a multiple attribute indicator testing protocol - while technically feasible and reliable, it was unacceptable to practice staff and raised concerns about potentially causing actual patient harm. Conclusions This indicator testing protocol is one example of a protocol that may be useful in assessing potential quality indicators when adapted to specific country health

  3. Scattered X-ray beam nondestructive testing

    International Nuclear Information System (INIS)

    Harding, G.; Kosanetzky, J.

    1988-01-01

    X-ray scatter interactions generally dominate the linear attenuation coefficient at the photon energies typical of medical and industrial radiography. Specific advantages of X-ray scatter imaging, including a flexible choice of measurement geometry, direct 3D-imaging capability (tomography) and improved information for material characterization, are illustrated with results from Compton and coherent scatter devices. Applications of a Compton backscatter scanner (ComScan) in the aerospace industry and coherent scatter imaging in security screening are briefly considered [pt

  4. 6. colloquium on quality assurance by materials testing. Proceedings

    International Nuclear Information System (INIS)

    2001-01-01

    This conference, now in its tenth year, has become an integral element of nondestructive testing research in Germany. It focuses on the role of nondestructive testing as a tool of in-house quality management and presents practical solutions. In accordance with its long tradition in the motor car industry, this is still a central field of interest. This CD-ROM provides information on shorter development times, diversified type production, modern high-productivity fabrication, and higher quality specifications. (orig.) [de

  5. A comparison of a niobium filter (NIOBI-X) with conventional filters in x-ray radiography

    International Nuclear Information System (INIS)

    Sandborg, M.; Alm Carlsson, G.

    1990-01-01

    A 0.05 mm thick x-ray filter of niobium (NIOBI-X) has been tested and the x-ray image quality and radiation doses have been compared with conventionel x-ray filters of copper and aluminium. The results show that for x-ray tube voltage higher than 50 kV or objects thicker than 50 mm a 0.05 mm thick niobium with benefit can be replaced by a 0.11 mm thick copper filter. (25 refs.) (K.A.E.)

  6. Metrological study of CFRP drilled holes with x-ray computed tomography

    OpenAIRE

    Kourra, Nadia; Warnett, Jason M.; Attridge, Alex; Kiraci, Ercihan; Gupta, Aniruddha; Barnes, Stuart; Williams, M. A. (Mark A.)

    2015-01-01

    The popularity of composite materials is continuously growing with new varieties being developed and tested with different machining processes to establish their suitability. Destructive as well as non-destructive methods, such as ultrasonics, X-ray radiography and eddy-current, have previously been used to ensure that the combination of particular machining methods and composites provide the required quality that can allow the required lifespan of the final product. X-ray computed tomography...

  7. Comparison of image quality among three x-ray systems for chest radiography: first step in optimisation

    International Nuclear Information System (INIS)

    Nocetti, D.; Ubeda, C.; Calcagno, S.; Acevedo, J.; Pardo, D.

    2015-01-01

    The aim of this study was to compare the performance of three digital X-ray systems [one flat-panel (DR) and two computed radiography (CR)] for chest radiography in terms of the entrance surface air kerma (ESAK) delivered to a polymethyl methacrylate phantom of 20 cm (equivalent to an adult patient) and image quality through of numerical evaluations using a test object (TO). The tube charge applied was ranged from 0.6 to 32 mAs, to a fixed tension of 125 kVp. The DR system presented the highest mean values of ESAK (615.9 μGy) along with the highest signal-to-noise ratio values, whereas CR systems showed a better high-contrast spatial resolution. Differences were statistically significant in both cases regarding the tube charge used. Thus, this parameter should be mainly considered to optimise the radiological protection through exposure settings selected. This survey represents the first effort to achieve optimisation in digital radiology for Chile. (authors)

  8. Quality control measurements for digital x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, N W [Department of Radiology, University Hospitals Leuven, 49 Herenstraat, 3000 Leuven (Belgium); Mackenzie, A [National Co-ordinating Centre for the Physics of Mammography, Medical Physics, Level B, St Luke' s Wing, The Royal Surrey County Hospital NHS Trust, Egerton Road, Guildford, GU2 7XX (United Kingdom); Honey, I D, E-mail: nicholas.marshall@uz.kuleuven.ac.be [Department of Medical Physics, Floor 3, Henriette Raphael House, Guy' s and St Thomas' Hospital, London, SE1 9RT (United Kingdom)

    2011-02-21

    This paper describes a digital radiography (DR) quality control protocol for DR detectors from the forthcoming report from the Institute of Physics and Engineering in Medicine (IPEM). The protocol was applied to a group of six identical caesium iodide (CsI) digital x-ray detectors to assess reproducibility of methods, while four further detectors were assessed to examine the wider applicability. Twelve images with minimal spatial frequency processing are required, from which the detector response, lag, modulation transfer function (MTF), normalized noise power spectrum (NNPS) and threshold contrast-detail (c-d) detectability are calculated. The x-ray spectrum used was 70 kV and 1 mm added copper filtration, with a target detector air kerma of 2.5 {mu}Gy for the NNPS and c-d results. In order to compare detector performance with previous imaging technology, c-d data from four screen/film systems were also acquired, at a target optical density of 1.5 and an average detector air kerma of 2.56 {mu}Gy. The DR detector images were typically acquired in 20 min, with a further 45 min required for image transfer and analysis. The average spatial frequency for the 50% point of the MTF for six identical detectors was 1.29 mm{sup -1} {+-} 0.05 (3.9% coefficient of variation (cov)). The air kerma set for the six systems was 2.57 {mu}Gy {+-} 0.13 (5.0% cov) and the NNPS at this air kerma was 1.42 x 10{sup -5} mm{sup 2} (6.5% cov). The detective quantum efficiency (DQE) measured for the six identical detectors was 0.60 at 0.5 mm{sup -1}, with a maximum cov of 10% at 2.9 mm{sup -1}, while the average DQE was 0.56 at 0.5 mm{sup -1} for three CsI detectors from three different manufacturers. Comparable c-d performance was found for these detectors (5.9% cov) with an average threshold contrast of 0.46% for 11 mm circular discs. The average threshold contrast for the S/F systems was 0.70% at 11 mm, indicating superior imaging performance for the digital systems. The protocol was found

  9. Quality control of aluminium casting: X ray radiography or tomography?

    International Nuclear Information System (INIS)

    Munier, B.; Tamziti, J.; Grignard, A.; Peix, G.; Kaftandjian, V.

    2007-01-01

    Full text of publication follows: X ray radiography has been for years a well known method commonly used for controlling parts either on line or off line. The purpose is to detect internal defects or to achieve reverse engineering on the parts. More recently two-dimensional or three-dimensional Computed Tomography has been introduced and provides key advantages over standard X ray radiography, such as dimensional measurement of complex objects with hidden structures and 3D defect localisation. However, from the user point of view, despite the clear advantages of tomography, the time consuming drawback is predominant, and thus, it is worth assessing the added value of tomography with respect to several radioscopic images. It is clear that there is no unique response to that question. If unacceptable defects are already detected in one radioscopic image, then the sample can be rejected and 3D tomography is useless. On another hand, 3D tomography cannot be replaced if internal structures such as holes must be measured with accuracy. The paper will present a comparison between radiography and tomography for controlling parts in the aluminium casting industry. Advantages and drawbacks of both methods will be reviewed. Performance features in both cases will be assessed in this specific industrial case by estimating the defect detection efficiency and image quality parameters. (authors)

  10. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Noel S. Ha

    2017-11-01

    Full Text Available Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET or single photon emission tomography (SPECT scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers must undergo quality control (QC testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a

  11. Artificial enzyme-powered microfish for water-quality testing.

    Science.gov (United States)

    Orozco, Jahir; García-Gradilla, Victor; D'Agostino, Mattia; Gao, Wei; Cortés, Allan; Wang, Joseph

    2013-01-22

    We present a novel micromotor-based strategy for water-quality testing based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants. The new micromotor toxicity testing concept mimics live-fish water testing and relies on the toxin-induced inhibition of the enzyme catalase, responsible for the biocatalytic bubble propulsion of tubular microengines. The locomotion and survival of the artificial microfish are thus impaired by exposure to a broad range of contaminants, that lead to distinct time-dependent irreversible losses in the catalase activity, and hence of the propulsion behavior. Such use of enzyme-powered biocompatible polymeric (PEDOT)/Au-catalase tubular microengine offers highly sensitive direct optical visualization of changes in the swimming behavior in the presence of common contaminants and hence to a direct real-time assessment of the water quality. Quantitative data on the adverse effects of the various toxins upon the swimming behavior of the enzyme-powered artificial swimmer are obtained by estimating common ecotoxicological parameters, including the EC(50) (exposure concentration causing 50% attenuation of the microfish locomotion) and the swimmer survival time (lifetime expectancy). Such novel use of artificial microfish addresses major standardization and reproducibility problems as well as ethical concerns associated with live-fish toxicity assays and hence offers an attractive alternative to the common use of aquatic organisms for water-quality testing.

  12. EVALUATION OF REINFORCING EFFECT ON FACEBOLTS FOR TUNNELING USING X-RAY CT AND CENTRIFUGE MODEL TEST

    Science.gov (United States)

    Takano, Daiki; Otani, Jun; Date, Kensuke; Yokot, Yasuhiro; Nagatani, Hideki

    The purpose of this paper is firstly to simulate the tunnel face failure in laboratory with four cases of model tests by pulling out tunnel model from a sandy ground that are without using auxiliary method nor facebolts and using facebolts with three different lengths of bolts, and secondary, to investigate the behavior of model ground using X-ray computed tomography (CT) scanner to visualize the failure zone in three dimensions. In addition to those results, a series of centrifuge model tests are conducted to confirm the results of X-ray CT test and also to discuss the ground behavior under full scale stress level. Finally, the effect of face bolting method is evaluated based on all the test results.

  13. Effects of film/foil interactions on X-ray image quality - experimental studies

    International Nuclear Information System (INIS)

    Maurer, H.J.; Goos, F.

    1985-01-01

    When assessing the quality of X-ray images, the interaction between film and foil should never be left out of account. Except for the case of green-emitting foils which require green-emitting films, films and foils are normally regarded separately, so that many variations are possible. The authors review the interaction between film and foil under practical aspects. Studies published so far have concentrated either on the amplification factor of foils or an the object imaging characteristics of certain films. Systematic studies on the interaction between film and foil have never been carried out. (orig.) [de

  14. Radiation levels and image quality in patients undergoing chest X-ray examinations

    International Nuclear Information System (INIS)

    Campos de Oliveira, Paulo Márcio; Carmo Santana, Priscila do; Sousa Lacerda, Marco Aurélio de; Silva, Teógenes Augusto da

    2017-01-01

    Patient dose monitoring for different radiographic procedures has been used as a parameter to evaluate the performance of radiology services; skin entrance absorbed dose values for each type of examination were internationally established and recommended aiming patient protection. In this work, a methodology for dose evaluation was applied to three diagnostic services: one with a conventional film and two with digital computerized radiography processing techniques. The x-ray beam parameters were selected and “doses” (specifically the entrance surface and incident air kerma) were evaluated based on images approved in European criteria during postero-anterior (PA) and lateral (LAT) incidences. Data were collected from 200 patients related to 200 PA and 100 LAT incidences. Results showed that doses distributions in the three diagnostic services were very different; the best relation between dose and image quality was found in the institution with the chemical film processing. This work contributed for disseminating the radiation protection culture by emphasizing the need of a continuous dose reduction without losing the quality of the diagnostic image. - Highlights: • A methodology for dose evaluation was applied to three diagnostic services. • The doses in patients were evaluated when the images were adequate. • Data were collected from 200 patients. • Is possible doses optimization with digital system without an image quality reduction. • The best dose and image quality was found in chemical film processing.

  15. Radiation doses and image quality in pediatric chest X-ray for the diagnosis of pneumonia in selected Latin American countries

    International Nuclear Information System (INIS)

    Jimenez, P.; Fleitas, I.; Cotelo, E.; Estevan, M.

    2008-01-01

    Full text: Pneumonia and acute lower respiratory infections in general, is the leading cause of child death in developing countries. According to the World Health Organization (WHO), 4 millions of children die annually due to this disease. Despite the growing use of vaccination as an alternate approach to reduce mortality, the increasing antimicrobial resistance and the high costs of vaccines remain important obstacles in the global struggle against the disease. The usual treatment strategy begins with a clinical examination of the patient followed by the prescription of a chest X-ray. Radiography would appear as the best available method for diagnosing pneumonia only if radiologists (and other health professionals such as pediatricians) knew how to interpret the images showed in the radiographs, and these meeting the standards of quality (anatomic structures, image contrast and optical density, and patient dose among other factors). On the other hand, special attention should be paid on patient doses due to children's specific radiosensitivity, repeated and extended use of chest x-ray in all Radiology Departments, and high rejection rate due to both equipment malfunction and to human skills shortcomings. Patient doses of chest X-ray performed to children less than 5 years old in PAHO Sentinel Hospitals for surveillance of bacterial pneumonias in various Latin American countries were estimated using technical parameters and equipment specifications. Image quality was compared to WHO criteria for chest X-rays quality. Results showing differences in patient doses translates on one hand the impact of specific characteristics of the radiological equipment, including equipment limitations and performance of the radiographs and on the other various and divers levels of health professionals skills and training on image quality interpretation and dose optimization. The study concludes that professionals' training and education on chest radiographs image quality constitutes

  16. Assessment of patient doses and image quality in X-ray diagnostics in Norway

    International Nuclear Information System (INIS)

    Olerud, H.M.

    1998-01-01

    Results from other industrialized countries indicate that the annual number of diagnostic procedures approaches one for every member of the population, and in many cases the individual radiation doses are higher than from any other human activity. Furthermore, the doses to patients for the same type of examination differ widely from place to place, suggesting that there is a considerable potential for dose reduction. This motivated an investigation of the diagnostic use of X-rays in Norway. The trends in the number of X-ray examinations performed annually have been studied. The patient doses (all diagnostics) and image quality (mammography and computed tomography) have been assessed for various radiological procedures. This form the basis for the assessment of total collective effective dose (CED) from X-rays in Norway, and further risk estimates. The radiological practice has then been evaluated according to the radiation protection principles of justification and optimisation. Based on the 1993 examination frequency, the total CED was assessed to 3400 manSv (0.78 mSv/inhabitant). It is estimated that this radiation burden may cause about 100 excess cancer deaths annually. The frequency of CT examination has doubled every fifth year, and did in 1993 represent 7% of the total number of examinations and 30% of the total CED. 129 refs

  17. Assessment of patient doses and image quality in X-ray diagnostics in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Olerud, H M

    1998-06-01

    Results from other industrialized countries indicate that the annual number of diagnostic procedures approaches one for every member of the population, and in many cases the individual radiation doses are higher than from any other human activity. Furthermore, the doses to patients for the same type of examination differ widely from place to place, suggesting that there is a considerable potential for dose reduction. This motivated an investigation of the diagnostic use of X-rays in Norway. The trends in the number of X-ray examinations performed annually have been studied. The patient doses (all diagnostics) and image quality (mammography and computed tomography) have been assessed for various radiological procedures. This form the basis for the assessment of total collective effective dose (CED) from X-rays in Norway, and further risk estimates. The radiological practice has then been evaluated according to the radiation protection principles of justification and optimisation. Based on the 1993 examination frequency, the total CED was assessed to 3400 manSv (0.78 mSv/inhabitant). It is estimated that this radiation burden may cause about 100 excess cancer deaths annually. The frequency of CT examination has doubled every fifth year, and did in 1993 represent 7% of the total number of examinations and 30% of the total CED. 129 refs.

  18. Audit protocol of compliance test on x-ray and interventional radiodiagnostic

    International Nuclear Information System (INIS)

    Endang Kunarsih; Fitria Sandra

    2011-01-01

    Testing protocol is a document that defined and implemented by the testing agency in conducting compliance testing to ensure that quality of testing implementation is planned and controlled in accordance with applicable regulations and standards. Testing protocol is required in filing an application to be a qualified testing agency. Auditors will review the testing protocol document to assess adequacy of the acceptance criteria before proceed to the next process. This paper presents the acceptance criteria required in an audit of the testing protocol document from the applicant of testing agency. (author)

  19. Use of portable X-ray fluorescence spectrometry for environmental quality assessment of peri-urban agriculture.

    Science.gov (United States)

    Weindorf, David C; Zhu, Yuanda; Chakraborty, Somsubhra; Bakr, Noura; Huang, Biao

    2012-01-01

    Urban expansion into traditional agricultural lands has augmented the potential for heavy metal contamination of soils. This study examined the utility of field portable X-ray fluorescence (PXRF) spectrometry for evaluating the environmental quality of sugarcane fields near two industrial complexes in Louisiana, USA. Results indicated that PXRF provided quality results of heavy metal levels comparable to traditional laboratory analysis. When coupled with global positioning system technology, the use of PXRF allows for on-site interpolation of heavy metal levels in a matter of minutes. Field portable XRF was shown to be an effective tool for rapid assessment of heavy metals in soils of peri-urban agricultural areas.

  20. Quality Control in Diagnostic Radiology: Experiences and Achievements

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Salleh; Muhammad Jamal Md Isa

    2015-01-01

    Malaysian Nuclear Agency through its Medical Physics Group has been providing Quality Control (QC) services for medical X-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The Medical Physics Groups services is endorsed by the Malaysian Ministry Of Health (MOH) and is in accordance with the Malaysian Standard MS 838 and the Atomic Energy Licensing Act, 1984. Until today, the scopes of testing services also include all types of medical x-ray apparatus. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss the experiences and achievements of providing QC service from early stage until now so that it can be shared by the citizens of the Malaysian Nuclear Agency. The results of quality assurance inspection of all types of X-ray apparatus for medical conducted by Agency Nuclear Malaysia will be presented in brief. (author)

  1. Quality of information accompanying on-line marketing of home diagnostic tests.

    Science.gov (United States)

    Datta, Adrija K; Selman, Tara J; Kwok, Tony; Tang, Teresa; Khan, Khalid S

    2008-01-01

    To assess the quality of information provided to consumers by websites marketing medical home diagnostic tests. A cross-sectional analysis of a database developed from searching targeted websites. Data sources were websites written in English which marketed medical home diagnostic tests. A meta-search engine was used to identify the first 20 citations for each type of home diagnostic medical test. Relevant websites limited to those written in English were reviewed independently and in triplicate, with disputes resolved by two further reviewers. Information on the quality of these sites was extracted using a pre-piloted performer. 168 websites were suitable for inclusion in the review. The quality of these sites showed marked variation. Only 24 of 168 (14.2%) complied with at least three-quarters of the quality items and just over half (95 of 168, 56.5%) reported official approval or certification of the test. Information on accuracy of the test marketed was reported by 87 of 168 (51.7%) websites, with 15 of 168 (8.9%) providing a scientific reference. Instructions for use of the product were found in 97 of 168 (57.9%). However, the course of action to be taken after obtaining the test result was stated in only 63 of 168 (37.5%) for a positive result and 43 of 168 (25.5%) for a negative result. The quality of information posted on commercial websites marketing home tests online is unsatisfactory and potentially misleading for consumers.

  2. Characterization of test specimens produced in reduced size for X-ray microtomography (µ-CT tests

    Directory of Open Access Journals (Sweden)

    E. E. BERNARDES

    Full Text Available Abstract The need to use reduced sample sizes, in order to attain improved spatial resolution in (µ-CT tests applied in Portland cement composites, makes researchers perform the fractionation of materials to obtain samples with dimensions compatible with the capacity of the scanning equipment, which might cause alterations in the microstructure under analysis. Therefore, a test specimen (TS with dimensions compatible with the scanning capacity of a microtomography system that operates with an X-ray tube and voltage ranging from 20 to 100 kV was proposed. Axial compression strength tests were made and their total porosity was assessed by an apparent density and solid fraction density ratio, which were obtained by means of mercury and helium pycnometry and µ-CT technique, respectively. The adoption of that TS has shown to be viable for providing a sample with a higher level of representation.

  3. The design and test of ellipsoidal glass capillaries as condensers for X-ray microscope

    International Nuclear Information System (INIS)

    Tian Jinping; Li Wenjie; Chen Jie; Liu Gang; Xiong Ying; Liu Longhua; Huang Xinlong; Tian Yangchao

    2008-01-01

    A high resolution X-ray microscope endstation was constructed on a wiggler beamline at the National Synchrotron Radiation Laboratory (NSRL). Parameters of the ellipsoidal glass capillaries as condensers were calculated and designed based on the illumination requests in the X-ray microscope system. Performance of the ellipsoidal glass capillaries was tested. The results indicate that the beam size agrees with the designed parameters and focus efficiencies of the ellipsoidal glass capillary condensers are better than 85%. (authors)

  4. Precise tests of x-ray scattering theories in the Compton regime

    International Nuclear Information System (INIS)

    Dunford, R. W.; Gemmell, D. S.; Kanter, E. P.; Kraessig, B.; Southworth, S. H.; Young, L.

    1999-01-01

    The authors report two experiments intended to test the accuracy of state-of-the-art theoretical predictions for x-ray scattering from low-Z atoms. The first one deals with the differential x-ray scattering cross sections in Ne and He from 11-22 keV and the Ne Compton-to-Rayleigh scattering ratio in this energy range. It was found that, in order to be consistent with the experimental results, an accurate description at low Z must include nonlocal exchange, electron correlation, and dynamic effects. The second experiment concerns the ratio of helium double-to-single ionization for Compton scattering in the 8-28 keV energy range where published experimental and theoretical results so far fail to give a consistent picture. The progress of the experiment and the data analysis is reported

  5. SU-D-209-02: Percent Depth Dose Curves for Fluoroscopic X-Ray Beam Qualities Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.

  6. Nondestructive testing diagnosis for corrosion and welding by means of hydrostatic test and gamma ray tomography

    International Nuclear Information System (INIS)

    Moura, Alex E.; Dantas, Carlos C.; Nery, Marcelo S.; Barbosa, Jose Maria A.; Rolim, Tiago L.; Melo, Silvio B.; Lima, Emerson A.O.

    2013-01-01

    Diagnoses of light and severe corrosion process in steel tubes are carried out and results are presented. The material discontinuity in metallic pieces was investigated and signals from gamma source detection shown defect present or no defect present. Samples taken from street illumination posts were placed in computerized gamma ray scan to investigate corrosion effect. Scanning at three angles 0 deg, 60 deg and 120 deg degrees with five repetitions provide data set sufficient to a statistical analysis. Samples taken from small diameter steel tubes with light corrosion were analyzed too. Comparing corrosion-free samples detection of transmission gamma ray shows that along with diameter reduction a random density distribution takes place with severe corrosive process. The asymmetry induced in sample density provided to be effective for diagnosis of light corrosion by means of straight-line slope obtained in gamma profile. Structural integrity of steel pipes affected by welding process and defect propagation due to Hydrostatic Testing - HT was simulated by numerical finite element method and data comparison with experimental gamma tomography was carried out. Samples of pipes with preexisting defect on the welding region were submitted to hydrostatic tests over working pressure and a correlation between defect degree and structural resistance was evaluated. (author)

  7. FIELD TEST OF THE FLAME QUALITY INDICATOR

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, Andrew M; Butcher, Thomas; Troost, Henry

    2003-02-04

    The flame quality indicator concept was developed at BNL specifically to monitor the brightness of the flame in a small oil burner and to provide a ''call for service'' notification when the brightness has changed from its setpoint, either high or low. In prior development work BNL has explored the response of this system to operational upsets such as excess air changes, fouled atomizer nozzles, poor fuel quality, etc. Insight Technologies, Inc. and Honeywell, Inc. have licensed this technology from the U.S. Department of Energy and have been cooperating to develop product offerings which meet industry needs with an optimal combination of function and price. Honeywell has recently completed the development of the Flame Quality Monitor (FQM or Honeywell QS7100F). This is a small module which connects via a serial cable to the burners primary operating control. Primary advantages of this approach are simplicity, cost, and ease of installation. Call-for-service conditions are output in the form of front panel indicator lights and contact closure which can trigger a range of external communication options. Under this project a field test was conducted of the FQM in cooperation with service organizations in Virginia, Pennsylvania, New Jersey, New York, and Connecticut. At total of 83 field sites were included. At each site the FQM was installed in parallel with another embodiment of this concept--the Insight AFQI. The AFQI incorporates a modem and provides the ability to provide detailed information on the trends in the flame quality over the course of the two year test period. The test site population was comprised of 79.5% boilers, 13.7% warm air furnaces, and 6.8% water heaters. Nearly all were of residential size--with firing rates ranging from 0.6 gallons of oil per hour to 1.25. During the course of the test program the monitoring equipment successfully identified problems including: plugged fuel lines, fouled nozzles, collapsed combustion

  8. Water Quality: A Field-Based Quality Testing Program for Middle Schools and High Schools.

    Science.gov (United States)

    Massachusetts State Water Resources Authority, Boston.

    This manual contains background information, lesson ideas, procedures, data collection and reporting forms, suggestions for interpreting results, and extension activities to complement a water quality field testing program. Information on testing water temperature, water pH, dissolved oxygen content, biochemical oxygen demand, nitrates, total…

  9. Application of the entropy concept to describe the quality of a X-ray beam

    International Nuclear Information System (INIS)

    Oliveira, A.D.

    2002-01-01

    In a previous work (Oliveira and Pedroso de Lima, 2000), we introduced the concept of entropy to describe the degradation of the energy of a photon beam incident in a material. We pointed out the relation between both, the entropy of the distribution of the energy deposited in matter and the traditional quality factor of the radiation protection. From the point of view of the entropy, we showed that, in what concerns to the monoenergetic approximation to a polyenergetic beam, we can hardly speak in an approximation (Oliveira 2001). In fact, the behaviour of the entropy is very different for both, an X-ray and a monoenergetic beam. In this work we developed further the study of the degradation of the energy of X-ray photons, from the point of view of the entropy, introducing the concepts of surface entropy, S surf , equilibrium entropy, S eq , and concepts of entropy variation, namely, primary to surface variation, S ps , and total entropy variation, S T . These are characteristic parameters of the X-ray beams describing the degradation of the primary photons while they interact with matter

  10. Quality of prenatal care questionnaire: instrument development and testing.

    Science.gov (United States)

    Heaman, Maureen I; Sword, Wendy A; Akhtar-Danesh, Noori; Bradford, Amanda; Tough, Suzanne; Janssen, Patricia A; Young, David C; Kingston, Dawn A; Hutton, Eileen K; Helewa, Michael E

    2014-06-03

    Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women's ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the "Support and Respect" subscale of the QPCQ and the "Respectfulness/Emotional Support" subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach's alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women's ratings of their quality of prenatal care did not change as a result of giving birth or between the early postpartum

  11. Quality of prenatal care questionnaire: instrument development and testing

    Science.gov (United States)

    2014-01-01

    Background Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Methods Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Results Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women’s ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the “Support and Respect” subscale of the QPCQ and the “Respectfulness/Emotional Support” subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach’s alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women’s ratings of their quality of prenatal care did not change as a result of giving

  12. Testing gravitational parity violation with coincident gravitational waves and short gamma-ray bursts

    International Nuclear Information System (INIS)

    Yunes, Nicolas; O'Shaughnessy, Richard; Owen, Benjamin J.; Alexander, Stephon

    2010-01-01

    Gravitational parity violation is a possibility motivated by particle physics, string theory, and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest itself as a discrepancy between these two distance measurements. We exemplify such a test by considering one specific effective theory that leads to such gravitational parity violation, Chern-Simons gravity. We show that the advanced LIGO-Virgo network and all-sky gamma-ray telescopes can be sensitive to the propagating sector of Chern-Simons gravitational parity violation to a level roughly 2 orders of magnitude better than current stationary constraints from the LAGEOS satellites.

  13. Radiography of X-ray in coral reefs

    International Nuclear Information System (INIS)

    Djoli Soembogo

    2016-01-01

    The application of X-ray radiography has been developed and it is already widely used in metal materials such as metal steel and carbon steel. This radiography using a source of radiation from X-ray machines. This research attempts to use the application of digital radiography X-ray source and use scanner Epson V700 positive films media for digitization results of conventional radiographic films on coral reefs. It has been testing radiography using Fuji film 100 to get the contrast medium, the sensitivity of the medium and image quality is good, Single Wall Single Image method , and using the media scanner films positive and X-ray sources, observation parameter are density radiographic film and the defect shape. Radiography uses Fuji film 100 to obtain a good contrast medium, good medium sensitivity and good quality image. Radiography of X-ray on coral reefs aims to find defects or discontinuities coral reefs such as porosity which would interfere with the determination of the age of the coral reefs. X-ray exposure time is 1 seconds for a thickness of 5.45 mm and 5.60 mm coral reefs by using a high voltage X-ray machine Rigaku of 130 kV. The result of the positive film scanner in the form of digital radiography that allows for the transfer of digital data or digital computerized data storage. The test results of radiographic on coral reefs with Single Wall Single Image method obtained radiographic film density parameter for Fuji film 100 on coral reefs No. 2 are 2.55; 2.53; 2.59 and on coral reefs No. 4 are 2.62; 2.65; 2.66, unsharpness geometric of radiographic results obtained 0.022 mm and 0.023 mm, sensitivity radiography are 1.648% and 1.604%. No defect found of Porosity that is significant. Status is acceptable for Fuji film 100, because the density of the film is in conformity with the standards referred to. Status of coral reefs No. 2 and No. 4 can be accepted, because it has conformed with the standards referred. (author)

  14. ITC Guidelines on Quality Control in Scoring, Test Analysis, and Reporting of Test Scores

    Science.gov (United States)

    Allalouf, Avi

    2014-01-01

    The Quality Control (QC) Guidelines are intended to increase the efficiency, precision, and accuracy of the scoring, analysis, and reporting process of testing. The QC Guidelines focus on large-scale testing operations where multiple forms of tests are created for use on set dates. However, they may also be used for a wide variety of other testing…

  15. Identification of the Quality Spot Welding used Non Destructive Test-Ultrasonic Testing: (Effect of Welding Time)

    Science.gov (United States)

    Sifa, A.; Endramawan, T.; Badruzzaman

    2017-03-01

    Resistance Spot Welding (RSW) is frequently used as one way of welding is used in the manufacturing process, especially in the automotive industry [4][5][6][7]. Several parameters influence the process of welding points. To determine the quality of a welding job needs to be tested, either by damaging or testing without damage, in this study conducted experimental testing the quality of welding or identify quality of the nugget by using Non-Destructive Test (NDT) -Ultrasonic Testing (UT), in which the identification of the quality of the welding is done with parameter thickness of worksheet after welding using NDT-UT with use same material worksheet and have more thickness of worksheet, the thickness of the worksheet single plate 1mm, with the capability of propagation Ultrasonic Testing (UT) standard limited> 3 mm [1], welding process parameters such as the time difference between 1-10s and the welding current of 8 KV, visually Heat Affected Zone ( HAZ ) have different results due to the length of time of welding. UT uses a probe that is used with a frequency of 4 MHz, diameter 10 mm, range 100 and the couplant used is oil. Identification techniques using drop 6dB, with sound velocity 2267 m / s of Fe, with the result that the effect of the Welding time affect the size of the HAZ, identification with the lowest time 1s show results capable identified joined through NDT - UT.

  16. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  17. State of development and development trends of X-ray image intensifier television systems

    International Nuclear Information System (INIS)

    Pfeiler, M.; Haendle, J.

    1975-01-01

    Following a survey on the development of X-ray image intensifier television systems up to now, their further development is critically discussed with regard to the better image quality to be expected. The introduction of the high-resolving X-ray image intensifier already meant an improvement in image quality even though the television system remained the same. In the image intensifier television system, the distinguishability of small details suffers from noise effects. Therefore, a better image quality is especially advantageous in those ranges of application which allow a higher picture dose. 'Electronic' radiography, intermittent screening, co-storage of the spotfilm radiographs, videometry, video area kymography, and cardiac stroboscopy are examples some of which have already been tested in clinical practice. (orig./AK) [de

  18. Quality of information accompanying on-line marketing of home diagnostic tests

    Science.gov (United States)

    Datta, Adrija K; Selman, Tara J; Kwok, Tony; Tang, Teresa; Khan, Khalid S

    2008-01-01

    Objective To assess the quality of information provided to consumers by websites marketing medical home diagnostic tests. Design A cross-sectional analysis of a database developed from searching targeted websites. Setting Data sources were websites written in English which marketed medical home diagnostic tests. Main outcome measures A meta-search engine was used to identify the first 20 citations for each type of home diagnostic medical test. Relevant websites limited to those written in English were reviewed independently and in triplicate, with disputes resolved by two further reviewers. Information on the quality of these sites was extracted using a pre-piloted performer. Results 168 websites were suitable for inclusion in the review. The quality of these sites showed marked variation. Only 24 of 168 (14.2%) complied with at least three-quarters of the quality items and just over half (95 of 168, 56.5%) reported official approval or certification of the test. Information on accuracy of the test marketed was reported by 87 of 168 (51.7%) websites, with 15 of 168 (8.9%) providing a scientific reference. Instructions for use of the product were found in 97 of 168 (57.9%). However, the course of action to be taken after obtaining the test result was stated in only 63 of 168 (37.5%) for a positive result and 43 of 168 (25.5%) for a negative result. Conclusions The quality of information posted on commercial websites marketing home tests online is unsatisfactory and potentially misleading for consumers. PMID:18263912

  19. First indirect x-ray imaging tests with an 88-mm diameter single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Macrander, A. T. [Argonne

    2017-02-01

    Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x - ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100 - micron thickness. The crystal was bonded to a fiber optic plat e (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self - supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream , adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB - based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. Lastly, this single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.

  20. Overview of the GEM muon system cosmic ray test program at the SSCL

    International Nuclear Information System (INIS)

    Milner, E.C.

    1993-04-01

    Muon track resolution exceeding 75-μm per plane is one of the main strengths of the GEM detector design, and will be crucial in searches for Higgs Bosons, heavy Z-Bosons, technicolor, and supersymmetry. Achieving this resolution coal requires improved precision in muon chambers and their alignment. A cosmic ray test stand known as the Texas Test Rio, (TTR) has been created at the SSCL for studying candidate GEM muon chamber technologies. Test results led to selecting Cathode Strip Chambers (CSC) as the GEM muon system baseline chamber technology

  1. A phantom test of proton-induced dual-energy X-ray angiography using iodinated contrast media

    International Nuclear Information System (INIS)

    Oguri, Y.; Hasegawa, J.; Ogawa, M.; Kaneko, J.; Sasa, K.

    2007-01-01

    Characteristic-line radiation from heavy metal targets bombarded by MeV proton beams has been tested as an X-ray source for dual-energy K-edge subtraction imaging for human angiography (blood vessel imaging) based on iodinated contrast media. To utilize the strong absorption by iodine (Z=53) at its K-absorption edge (33.2 keV), we used K α -line of La (lanthanum, Z=57) at 33.4 keV. As a reference, also K α X emission of Sn (tin, Z=50) at 25.2 keV was employed. Metallic plates of La and Sn were irradiated by 7-MeV protons to produce these characteristic X-rays. Energy-subtraction method was tested using Lucite phantoms which contain aqueous solutions of KI (potassium iodide) with different concentrations. Also Ca(H 2 PO 4 ) 2 powder was stuffed in these phantoms to simulate bones. The transmission images of the phantoms were recorded on imaging plates. During the exposure, the energy spectra of the X-rays were monitored by a CdTe detector. We found that the contrast of images of iodide solutions taken with La X-rays was higher than that with Sn X-rays. Also the energy subtraction procedure was successfully applied to reduce the graphical noise due to the bones and inhomogeneity of the soft tissue. However, to apply the present method to actual clinical use, the X-ray intensity must be increased by several orders of magnitude. Also the transmission of the 'lower-energy' photons has to be a few orders higher for imaging of objects as thick as human chest. (author)

  2. Standard test method for determining the effective elastic parameter for X-ray diffraction measurements of residual stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a procedure for experimentally determining the effective elastic parameter, Eeff, for the evaluation of residual and applied stresses by X-ray diffraction techniques. The effective elastic parameter relates macroscopic stress to the strain measured in a particular crystallographic direction in polycrystalline samples. Eeff should not be confused with E, the modulus of elasticity. Rather, it is nominally equivalent to E/(1 + ν) for the particular crystallographic direction, where ν is Poisson's ratio. The effective elastic parameter is influenced by elastic anisotropy and preferred orientation of the sample material. 1.2 This test method is applicable to all X-ray diffraction instruments intended for measurements of macroscopic residual stress that use measurements of the positions of the diffraction peaks in the high back-reflection region to determine changes in lattice spacing. 1.3 This test method is applicable to all X-ray diffraction techniques for residual stress measurem...

  3. Optimization of a readout board for mass assembly and light yield measurements with a cosmic ray test stand

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Phi [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik (Germany); Collaboration: CALICE-D-Collaboration

    2016-07-01

    We have built a readout board prototype, equipped with SiPMs, scintillators and readout electronics for an highly granular calorimeter. The design was optimized for mass assembly due to about 8 million channels in the final detector. The prototype showed good performance in several test beams and in a cosmic ray test stand, which was built to characterize the MIP response of these kinds of boards. We show an overview of the cosmic ray test stand and measurement results for the readout board and plans for an improved 2nd generation prototype.

  4. Robustness testing in pharmaceutical freeze-drying: inter-relation of process conditions and product quality attributes studied for a vaccine formulation.

    Science.gov (United States)

    Schneid, Stefan C; Stärtzel, Peter M; Lettner, Patrick; Gieseler, Henning

    2011-01-01

    The recent US Food and Drug Administration (FDA) legislation has introduced the evaluation of the Design Space of critical process parameters in manufacturing processes. In freeze-drying, a "formulation" is expected to be robust when minor deviations of the product temperature do not negatively affect the final product quality attributes. To evaluate "formulation" robustness by investigating the effect of elevated product temperature on product quality using a bacterial vaccine solution. The vaccine solution was characterized by freeze-dry microscopy to determine the critical formulation temperature. A conservative cycle was developed using the SMART™ mode of a Lyostar II freeze dryer. Product temperature was elevated to imitate intermediate and aggressive cycle conditions. The final product was analyzed using X-ray powder diffraction (XRPD), scanning electron microscopy (SEM), Karl Fischer, and modulated differential scanning calorimetry (MDSC), and the life cell count (LCC) during accelerated stability testing. The cakes processed at intermediate and aggressive conditions displayed larger pores with microcollapse of walls and stronger loss in LCC than the conservatively processed product, especially during stability testing. For all process conditions, a loss of the majority of cells was observed during storage. For freeze-drying of life bacterial vaccine solutions, the product temperature profile during primary drying appeared to be inter-related to product quality attributes.

  5. Standard test method for quantitative determination of americium 241 in plutonium by Gamma-Ray spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers the quantitative determination of americium 241 by gamma-ray spectrometry in plutonium nitrate solution samples that do not contain significant amounts of radioactive fission products or other high specific activity gamma-ray emitters. 1.2 This test method can be used to determine the americium 241 in samples of plutonium metal, oxide and other solid forms, when the solid is appropriately sampled and dissolved. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Measurement of parameters for the quality control of X-ray units by using PIN diodes and a personal computer

    International Nuclear Information System (INIS)

    Ramirez, F.; Gaytan, E.; Mercado, I.; Estrada, M.; Cerdeira, A.

    2000-01-01

    The design of a new system for the measurement of the main parameters of X-ray units used in medicine is presented. The system measures automatically the exposure time, high voltage applied, waveform of the detected signal, exposure ratio and the total exposure (dose). The X-ray detectors employed are PIN diodes developed at CINVESTAV, the measurements are done in one single shot, without invasion of the X-ray unit. The results are shown in the screen of the computer and can be saved in a file for later analysis. The proposed system is intended to be used in the quality control of X-rays units for clinical radio-diagnosis. It is a simple and inexpensive equipment if compared with available commercial equipment that uses ionization chambers and accurate electrometers that small facilities and hospitals cannot afford

  7. Quality control of X-ray films with blue spectral sensitivity: comparative study

    International Nuclear Information System (INIS)

    Carrasco, F.; Ruiz Cruces, R.; Sendra, F.; Diez de los rios, A.

    1994-01-01

    In this work, seven X-ray films with blue-ultraviolet spectral sensitivity have been studied by means of light sensitometry, x-ray sensitometry and spatial resolution test. Three screens of different composition and speed were use. Only the films HPX44 and RG showed a high base plus for (>0,30), the remaining films maintained their values between 0,21 and 0,26. When blue light sensitometry was substituted by green light sensitometry, base plus fog practically did not show variations and gradient and speed changed less than 4% and 10% respectively. Speed and Gradient must be calculated from the relation between exposition and optical density, avoiding parameters referred to type optical density of a given step of the wedge. Two films with high speed (RG and HPX 44), four films with medium speed (Curix RP2, NewRX, Cronex 4 and X-Omat S) and one film with low speed but high resolution (Cronex 7) have been found. The obtained results present useful comparative data to select and adequate film according to the characteristic of the x-ray examination and the available screens. (Author)

  8. Optimization of image quality and acquisition time for lab-based X-ray microtomography using an iterative reconstruction algorithm

    Science.gov (United States)

    Lin, Qingyang; Andrew, Matthew; Thompson, William; Blunt, Martin J.; Bijeljic, Branko

    2018-05-01

    Non-invasive laboratory-based X-ray microtomography has been widely applied in many industrial and research disciplines. However, the main barrier to the use of laboratory systems compared to a synchrotron beamline is its much longer image acquisition time (hours per scan compared to seconds to minutes at a synchrotron), which results in limited application for dynamic in situ processes. Therefore, the majority of existing laboratory X-ray microtomography is limited to static imaging; relatively fast imaging (tens of minutes per scan) can only be achieved by sacrificing imaging quality, e.g. reducing exposure time or number of projections. To alleviate this barrier, we introduce an optimized implementation of a well-known iterative reconstruction algorithm that allows users to reconstruct tomographic images with reasonable image quality, but requires lower X-ray signal counts and fewer projections than conventional methods. Quantitative analysis and comparison between the iterative and the conventional filtered back-projection reconstruction algorithm was performed using a sandstone rock sample with and without liquid phases in the pore space. Overall, by implementing the iterative reconstruction algorithm, the required image acquisition time for samples such as this, with sparse object structure, can be reduced by a factor of up to 4 without measurable loss of sharpness or signal to noise ratio.

  9. Overview of Power Quality and Integrated Testing at JSC

    Science.gov (United States)

    Davies, Francis

    2018-01-01

    This presentation describes the basic philosophy behind integrated testing and partially integrated testing. It lists some well known errors in space systems that were or could have been caught during integrated testing. Two examples of integrated testing at the Johnson Space Center (JSC) are mentioned, and then an overview of two test facilities that do power testing (partially integrated testing) at JSC are presented, with information on the capabilities of each. Finally a list of three projects that has problems caught during power quality or Electromagnetic Interference (EMI) testing is presented.

  10. LISA Pathfinder test-mass charging during galactic cosmic-ray flux short-term variations

    Science.gov (United States)

    Grimani, C.; Fabi, M.; Lobo, A.; Mateos, I.; Telloni, D.

    2015-02-01

    Metal free-floating test masses aboard the future interferometers devoted to gravitational wave detection in space are charged by galactic and solar cosmic rays with energies \\gt 100 MeV/n. This process represents one of the main sources of noise in the lowest frequency band (\\lt 10-3 Hz) of these experiments. We study here the charging of the LISA Pathfinder (LISA-PF) gold-platinum test masses due to galactic cosmic-ray (GCR) protons and helium nuclei with the Fluka Monte Carlo toolkit. Projections of the energy spectra of GCRs during the LISA-PF operations in 2015 are considered. This work was carried out on the basis of the solar activity level and solar polarity epoch expected for LISA-PF. The effects of GCR short-term variations are evaluated here for the first time. Classical Forbush decreases, GCR variations induced by the Sun rotation, and fluctuations in the LISA-PF frequency bandwidth are discussed.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  14. Physical-Chemical and Mechanical characterization of some cement products in Madagascar by using Technical Analysis X-ray Fluorescence and tests receptions

    International Nuclear Information System (INIS)

    Rasolondraibe, I.P.

    2014-01-01

    The present work is completely realized at the 'Institut National des Sciences et Techniques Nucleaires (INSTN - Madagascar)' and 'Laboratoire National des Travaux Publics et du Batiment (LNTPB)'. Its purpose is to carry out the physico - chemical and mechanical analysis of the cements products present in Madagascar in order to ensure their qualities in case of Building and Publics Works construction safety. The necessary chemical elements in cements are the loss in ignition (LOI), the insoluble residues (RI), the silica (SiO 2 ), the lime (CaO), the alumina (Al 2 O 3 ), the iron oxide (Fe 2 O 3 ), the magnesia (MgO) and the sulfate (SO 3 ). In this work, analytical laboratory in X - Ray fluorescence department of INSTN - Madagascar using the direct excitation X - Ray fluorescence technique outline their research on lime and iron oxide while L.N.T.P.B materials laboratory can make all using test method by gravimetry and titrimetry according to EN 196 - 2. The results of INSTN - Madagascar show that the concentrations of calcium oxide and iron oxide are consistent with the concentration range provided by the laboratory materials L.N.T.P.B respectively equal to 50.00 % - 65.00 % and 1.00 % - 5.00 %. The results between the two laboratories have a - 4.76 % iron oxide maximum relative deviation and 4,77 % calcium oxide maximum relative deviation. Complementary physical and mechanical tests were performed at L.N.T.P.B materials laboratory respectively in accordance with EN 196 - 3 and EN 196 - 1. The used conventional X - ray fluorescence method fulfill the scope of application needed with good correlation less than ± 5 %. [fr

  15. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  16. Effect of 60Co-γ ray irradiation on green coffee beans, 1

    International Nuclear Information System (INIS)

    Tomoda, Goro; Matsuyama, Jun; Hiramoto, Keiko; Izu, Kumie

    1977-01-01

    Green coffee beans were irradiated with 60 Co-γ rays at doses of 0, 0.05, 0.5, 5.0 and 10.0 Mrad and the changes of general components in green and roast coffee beans were investigated together with those of the organoleptic properties of roast beans during storage according to the cup testing. In case of Brazil santos beans, irradiation of some 0.05 Mrad 60 Co-γ ray gave rather favourable mild flavour and no harmful influence on the quality of coffee, and moreover, would tend to extend the shelf life of roast beans. But influence of irradiation on the quality of coffee differed somewhat between two cultivars, Brazil santos and Colombia. (auth.)

  17. Au-coated X-ray Anti-scattering Grid Performance Test by MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Bae, JunWoo; Yoo, Dong Han; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    It is required to protect individual against the dangers of ionizing radiation from medical exposure. And increasing of resolution for x-ray radiography tools can give radiation protectoral benefits. Because the image device has higher resolution in same energy source, it requires low energy level source and it can reduce individual dose. The anti-scattering grid is sub-device that is attached in front of detector (direction of source). It is square lattice shape generally. It is composed of penetration parts and shielding parts. Penetration part is generally air (the void) and in some studies it uses wood or aluminum. Shielding part is composed of various materials such as lead or copper. In this study, it is focused on the gold as one of X-ray grid materials, where gold is generally known as excellent shielding material and the performance test on the gold coated anti-scattering grid is carried out by MCNP simulation. X-ray grid was simulated by using MCNP code and its performance was investigated. It was understood that glass based and Au-coated grid could lessen the scattered photons more where the reduction was about two third. In further study, geometry optimization or material selection will be conducted by MCNP simulation for giving benefits to design proper grid for various instruments.

  18. Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

    Science.gov (United States)

    den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R

    1994-06-01

    Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and

  19. Radiation levels and image quality in patients undergoing chest X-ray examinations

    Science.gov (United States)

    de Oliveira, Paulo Márcio Campos; do Carmo Santana, Priscila; de Sousa Lacerda, Marco Aurélio; da Silva, Teógenes Augusto

    2017-11-01

    Patient dose monitoring for different radiographic procedures has been used as a parameter to evaluate the performance of radiology services; skin entrance absorbed dose values for each type of examination were internationally established and recommended aiming patient protection. In this work, a methodology for dose evaluation was applied to three diagnostic services: one with a conventional film and two with digital computerized radiography processing techniques. The x-ray beam parameters were selected and "doses" (specifically the entrance surface and incident air kerma) were evaluated based on images approved in European criteria during postero-anterior (PA) and lateral (LAT) incidences. Data were collected from 200 patients related to 200 PA and 100 LAT incidences. Results showed that doses distributions in the three diagnostic services were very different; the best relation between dose and image quality was found in the institution with the chemical film processing. This work contributed for disseminating the radiation protection culture by emphasizing the need of a continuous dose reduction without losing the quality of the diagnostic image.

  20. Sampling analytical tests and destructive tests for quality assurance

    International Nuclear Information System (INIS)

    Saas, A.; Pasquini, S.; Jouan, A.; Angelis, de; Hreen Taywood, H.; Odoj, R.

    1990-01-01

    In the context of the third programme of the European Communities on the monitoring of radioactive waste, various methods have been developed for the performance of sampling and measuring tests on encapsulated waste of low and medium level activity, on the one hand, and of high level activity, on the other hand. The purpose was to provide better quality assurance for products to be stored on an interim or long-term basis. Various testing sampling means are proposed such as: - sampling of raw waste before conditioning and determination of the representative aliquot, - sampling of encapsulated waste on process output, - sampling of core specimens subjected to measurement before and after cutting. Equipment suitable for these sampling procedures have been developed and, in the case of core samples, a comparison of techniques has been made. The results are described for the various analytical tests carried out on the samples such as: - mechanical tests, - radiation resistance, - fire resistance, - lixiviation, - determination of free water, - biodegradation, - water resistance, - chemical and radiochemical analysis. Every time it was possible, these tests were compared with non-destructive tests on full-scale packages and some correlations are given. This word has made if possible to improve and clarify sample optimization, with fine sampling techniques and methodologies and draw up characterization procedures. It also provided an occasion for a first collaboration between the laboratories responsible for these studies and which will be furthered in the scope of the 1990-1994 programme

  1. Combustion tests with different pellet qualities

    International Nuclear Information System (INIS)

    Bachs, A.; Dahlstroem, J.E.; Persson, Henrik; Tullin, C.

    1999-05-01

    Eight different pellet qualities with the diameters 6, 8 and 10 mm, from eight different producers has been tested in three pellet burners and two pellet stoves. The objective was to investigate how different diameter affect the emissions of CO, OGC and NO x . Previous experience has indicated that the pellet diameter could have significant importance for the combustion. This was not verified in the study. It showed contradictory that the diameter has a minor effect on the combustion result. The study shows that different combustion equipment give different emission. For e g hydrocarbon emissions the difference is a factor 2.2 between the 'best' and the 'worst' equipment fired on full load. The difference increases to 2.7 with lower load. The choice of fuel has a big importance for the quality of the combustion. For hydrocarbons the emissions could in an extreme situation differ with a factor 25 between 'best' and 'worst' fuel. More normally the difference is about a factor of five. Nitrogen oxide emissions are to a major part related to the nitrogen contents in the fuel. The difference between the 'best' and 'worst' fuel is in the range of a factor two. Tests with the same fuel in different equipment gives a variation of 20-30%. The combustion result depends on both the pellet quality and the equipment and there is no fuel that is good in all equipment. The big variation in combustion results shows that there is a big indifference between fuels used for small scale heating Project report from the program: Small scale combustion of biofuels. 2 refs, 15 figs, 5 tabs

  2. Development of Object Simulator for Radiation Field of Dental X-Rays

    International Nuclear Information System (INIS)

    Silva, L F; Ferreira, F C L; Sousa, F F; Cardoso, L X; Vasconcelos, E D S; Brasil, L M

    2013-01-01

    In dentistry radiography is of fundamental importance to the dentist can make an accurate diagnosis. For this it is necessary to pay attention to the radiological protection of both the professional and the patient and control image quality for an accurate diagnosis. In this work, quality control tests were performed on X-ray machines in private dental intraoral in the municipality of Marabá, where they measured the diameters of the radiation field to see if these machines are in accordance with the recommendations, thus preventing the patient is exposed to a radiation field higher than necessary. We will study the results of each X-ray machine evaluated. For this we created a phantom to assess the size of the radiation field of X-ray dental, where we measure the radiation field of each device to see if they are in accordance with the recommendations of the ordinance No. 453/98 – MS

  3. Effect of oblique ray on image quality of direct digitized radiography system

    International Nuclear Information System (INIS)

    Song Yuquan; Wu Xiaomei; Deng Yu; He Jianxun; Xiao Shaoping; He Zhecheng; Yu Cixi

    2005-01-01

    Objective: To evaluate the effec on image quality of DDR system caused by oblique ray. Methods: (1) Experiment group: A sphere was taken radiographes repeatedly using DDR system, the respective incidence were vertical (0 degree), 15 degree, 30 degree, 45 degree, and all images were printed into laser films. (2) Comparison group: By way of self comparing, conventional films were radio graphed under all conditions as in experiment group with screen-film system instead of flat-panel detector. (3) To evaluate the edge fog of sphere image, micro-density of image edge. Both groups were measured separately. Results: (1) The image edge fog in both experiment group and comparison group increased along with increase of X-ray incidence, the more large angle was, the more amplitude of image fog was. And the amplitude of experiment group was more distinct while with large incidence. When incidence was 45 degree, the edge fog value of experiment group went up to (0.9240±0.0033) mm, while only (0.4840±0.0033) mm of comparison group contrarily. (2) When projecting with 15 degree inclination of tube, the amplitude of variation of image edge fog in both DDR system and screen-film system had no distinct difference (P>0.05); when the lean angle were 30 degree and 45 degree, it had distinct difference (P<0.05). Conclusion: (1) The image edge fog of DDR system has no distinctly difference from screen-film system and better image gotten while the inclination of tube is vertical or small angle. (2) The amplitude of variation of image edge fog have distinctly difference that it of DDR system is visibly over screen-film system, when the inclination of tube is big, the imaging quality will be affected. (authors)

  4. Quality control and standardization of forearm X-ray osteodensitometry

    International Nuclear Information System (INIS)

    Boyanov, M.

    2000-01-01

    Quality control (QC) has an essential practical bearing on the proper function of the equipment used for bone density measurement. Special attention is likewise focused on the issue of standardization of the results afforded by different osteodensitometry instruments. It is the purpose of the study to assay QC of a single-energy x-ray forearm osteodensitometry unit DTX-100 covering a 3 year period, and compare the data on bone mineral density (BMD) produced by three different devices. Long-term BMD reproducibility in vitro, expressed as coefficient of variation, amounts to 0.55 per cent. Except for a two week period, no deviation from the normal function of the instrument is documented. Failing to comply with the manufacturer's instructions may discredit QC efficacy. On comparative assessment of the results produced by different osteodensitometers, differences in vivo may reach up to 1.2 standard deviation. Definite regions of special interest, feasible for comparison, are recommended. In conclusion special emphasis is laid on the necessity of performing through QC, measurement results standardization and accreditation of a reference osteodensitometry center

  5. Study on the testing standards of quality assurance for CT image

    International Nuclear Information System (INIS)

    Liu Jingxin; Yang Haishan; Liu Gang; Wang Liyun

    2000-01-01

    Objective: To establish national testing standards of quality assurance for CT image. Methods: 104 sets of CT system were tested using quality assurance test phantoms and devices including American RMI 461A, RMI 463, MDH 1015 C with ION Chamber, Sweden UNF 9004 kvp meter. These CT were made from different manufacturers including out of date of CT and state-of-art spiral CT system. Thirteen kinds of standards on CT from different countries and 87 sets of technical specifications of CT were collected. The results of the test were compared using phantoms of RMI, Victoreen, Catphan on the same CT system (Siemens HQS). Results: Based on the test results of this study, with reference to the foreign standards and some of regulations in China, CT test items should include high contrast resolution, low contrast resolution, noise, uniformity, mean CT unit, dose slice thickness, localization light, positioning of patient support and gantry tilt. Standards including acceptance test, status test, and constancy test were made in specification. Among them, constancy test equals to IEC 122-2-6; items and results in acceptance test are stricter than in the status test; and low contrast resolution, uniformity, localization light accuracy and positioning of patient support in the acceptance test are even stricter than that in foreign standards. Conclusion: The testing standards of quality assurance for CT developed in this study shows practical and useful in China, which supplemented to the existing international standards

  6. Best Practices: Power Quality and Integrated Testing at JSC

    Science.gov (United States)

    Davis, Lydia

    2018-01-01

    This presentation discusses Best Practices for Power Quality and Integrated Testing at JSC in regards to electrical systems. These high-level charts include mostly generic information; however, a specific issue is discussed involving flight hardware that could have been discovered prior to flight with an integrated test.

  7. Quality control in veterinary radiology: application of X-ray sets in veterinary practices and measurements of radiation exposure at taking

    International Nuclear Information System (INIS)

    Horvat, C.

    1986-10-01

    In a first part a survey was made by questionnaires from veterinary doctors about the existence and use of X-ray sets in their practices. Special attention is given to the quality of X-ray shots. In part two stray radiation measurements under typical conditions were performed and the radiation burden of the personnel estimated. The results is that because of the small number of shots the burden is safely below the legal limits. (G.Q.)

  8. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  9. Test Code Quality and Its Relation to Issue Handling Performance

    NARCIS (Netherlands)

    Athanasiou, D.; Nugroho, A.; Visser, J.; Zaidman, A.

    2014-01-01

    Automated testing is a basic principle of agile development. Its benefits include early defect detection, defect cause localization and removal of fear to apply changes to the code. Therefore, maintaining high quality test code is essential. This study introduces a model that assesses test code

  10. The emission of Gamma Ray Bursts as a test-bed for modified gravity

    Directory of Open Access Journals (Sweden)

    S. Capozziello

    2015-11-01

    Full Text Available The extreme physical conditions of Gamma Ray Bursts can constitute a useful observational laboratory to test theories of gravity where very high curvature regimes are involved. Here we propose a sort of curvature engine capable, in principle, of explaining the huge energy emission of Gamma Ray Bursts. Specifically, we investigate the emission of radiation by charged particles non-minimally coupled to the gravitational background where higher order curvature invariants are present. The coupling gives rise to an additional force inducing a non-geodesic motion of particles. This fact allows a strong emission of radiation by gravitationally accelerated particles. As we will show with some specific model, the energy emission is of the same order of magnitude of that characterizing the Gamma Ray Burst physics. Alternatively, strong curvature regimes can be considered as a natural mechanism for the generation of highly energetic astrophysical events. Possible applications to cosmology are discussed.

  11. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-09-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing both properties separately are available it is desirable that the method permits the assessment of all the relevant properties together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas radiographic image thicknesses. The use of the constant exposure technique could be used to compare both the sensitometric properties as well as the image quality for different radiographic materials. It consist of exposing different film or paper brands at a chosen, constant mAmin exposure when testing radiographic image quality for different thicknesses of a given material. From the results obtained with the constant exposure technique conclusions are drawn about its applicability as a standard method for assessing radiographic film and paper. (author)

  12. Quality control of test iodine in urine by spectrophotometry UV-Vis

    Science.gov (United States)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  13. Is reverberation time adequate for testing the acoustical quality of unroofed auditoriums?

    DEFF Research Database (Denmark)

    Paini, Dario; Gade, Anders Christian; Rindel, Jens Holger

    2006-01-01

    30) and other acoustical parameters normally used to test the acoustical quality of closed auditoria, such as concert halls, theatres, opera houses, are suitable and sufficient for testing the acoustical quality of open performance spaces. Simulations as well as measurements were carried out to study...

  14. Quality Control Assessment of Radiology Devices in Kerman Province, Iran

    Directory of Open Access Journals (Sweden)

    Zahra Jomehzadeh

    2016-03-01

    Full Text Available Introduction Application of quality control (QC programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests were performed on 28 conventional radiographic X-ray units in Kerman governmental hospitals, based on the protocols and criteria recommended by the Atomic Energy Organization of Iran (AEOI, using a calibrated Gammex QC kit. Each section of the QC kit incorporated different models. Results Based on the findings, kVp accuracy, kVp reproducibility, timer accuracy, timer reproducibility, exposure reproducibility, mA/timer linearity, and half-value layer were not within the acceptable limits in 25%, 4%, 29%, 18%, 11%, 12%, and 7% of the evaluated units (n=28, respectively. Conclusion As radiographic X-ray equipments in Kerman province are relatively old with a high workload, it is recommended that AEOI modify the current policies by changing the frequency of QC test implementation to at least once a year.

  15. An alternative approach to contrast-detail testing of X-ray image intensifier systems

    International Nuclear Information System (INIS)

    Kotre, C.J.; Marshall, N.W.; Faulkner, K.

    1992-01-01

    The difficulties of making the results of threshold contrast-detail diameter tests on X-ray image intensifier systems consistent with published performance standards are discussed. The current approach to contrast-detail testing is described and an alternative method intended to give greater consistency for all image intensifier input field diameters proposed. The current and alternative test conditions are compared on two image intensifier systems. The results obtained show that the contrast-detail curves for image intensifier systems with a wide range of input field diameters can be effectively normalized to be directly comparable to a common reference standard by applying the proposed alternative test conditions. The implications of this result on the interpretation of the contrast-detail test are discussed. (author)

  16. Connecting optical and X-ray tracers of galaxy cluster relaxation

    Science.gov (United States)

    Roberts, Ian D.; Parker, Laura C.; Hlavacek-Larrondo, Julie

    2018-04-01

    Substantial effort has been devoted in determining the ideal proxy for quantifying the morphology of the hot intracluster medium in clusters of galaxies. These proxies, based on X-ray emission, typically require expensive, high-quality X-ray observations making them difficult to apply to large surveys of groups and clusters. Here, we compare optical relaxation proxies with X-ray asymmetries and centroid shifts for a sample of Sloan Digital Sky Survey clusters with high-quality, archival X-ray data from Chandra and XMM-Newton. The three optical relaxation measures considered are the shape of the member-galaxy projected velocity distribution - measured by the Anderson-Darling (AD) statistic, the stellar mass gap between the most-massive and second-most-massive cluster galaxy, and the offset between the most-massive galaxy (MMG) position and the luminosity-weighted cluster centre. The AD statistic and stellar mass gap correlate significantly with X-ray relaxation proxies, with the AD statistic being the stronger correlator. Conversely, we find no evidence for a correlation between X-ray asymmetry or centroid shift and the MMG offset. High-mass clusters (Mhalo > 1014.5 M⊙) in this sample have X-ray asymmetries, centroid shifts, and Anderson-Darling statistics which are systematically larger than for low-mass systems. Finally, considering the dichotomy of Gaussian and non-Gaussian clusters (measured by the AD test), we show that the probability of being a non-Gaussian cluster correlates significantly with X-ray asymmetry but only shows a marginal correlation with centroid shift. These results confirm the shape of the radial velocity distribution as a useful proxy for cluster relaxation, which can then be applied to large redshift surveys lacking extensive X-ray coverage.

  17. Data Quality Objectives For Selecting Waste Samples To Test The Fluid Bed Steam Reformer Test

    International Nuclear Information System (INIS)

    Banning, D.L.

    2010-01-01

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Fluid Bed Steam Reformer testing. The type, quantity and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluid bed steam reformer (FBSR). A determination of the adequacy of the FBSR process to treat Hanford tank waste is required. The initial step in determining the adequacy of the FBSR process is to select archived waste samples from the 222-S Laboratory that will be used to test the FBSR process. Analyses of the selected samples will be required to confirm the samples meet the testing criteria.

  18. [Procedure of seed quality testing and seed grading standard of Prunus humilis].

    Science.gov (United States)

    Wen, Hao; Ren, Guang-Xi; Gao, Ya; Luo, Jun; Liu, Chun-Sheng; Li, Wei-Dong

    2014-11-01

    So far there exists no corresponding quality test procedures and grading standards for the seed of Prunus humilis, which is one of the important source of base of semen pruni. Therefor we set up test procedures that are adapt to characteristics of the P. humilis seed through the study of the test of sampling, seed purity, thousand-grain weight, seed moisture, seed viability and germination percentage. 50 cases of seed specimens of P. humilis tested. The related data were analyzed by cluster analysis. Through this research, the seed quality test procedure was developed, and the seed quality grading standard was formulated. The seed quality of each grade should meet the following requirements: for first grade seeds, germination percentage ≥ 68%, thousand-grain weight 383 g, purity ≥ 93%, seed moisture ≤ 5%; for second grade seeds, germination percentage ≥ 26%, thousand-grain weight ≥ 266 g, purity ≥ 73%, seed moisture ≤9%; for third grade seeds, germination percentage ≥ 10%, purity ≥ 50%, thousand-grain weight ≥ 08 g, seed moisture ≤ 13%.

  19. Quality Indicators for the Total Testing Process.

    Science.gov (United States)

    Plebani, Mario; Sciacovelli, Laura; Aita, Ada

    2017-03-01

    ISO 15189:2012 requires the use of quality indicators (QIs) to monitor and evaluate all steps of the total testing process, but several difficulties dissuade laboratories from effective and continuous use of QIs in routine practice. An International Federation of Clinical Chemistry and Laboratory Medicine working group addressed this problem and implemented a project to develop a model of QIs to be used in clinical laboratories worldwide to monitor and evaluate all steps of the total testing process, and decrease error rates and improve patient services in laboratory testing. All laboratories are invited, at no cost, to enroll in the project and contribute to harmonized management at the international level. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Limited streamer chamber testing and quality evaluation in ASTRA

    International Nuclear Information System (INIS)

    Anzivino, G.; Bianco, S.; Casaccia, R.

    1991-01-01

    Limited streamer chambers are extensively used for high-energy and nuclear physics experiments in accelerator and underground laboratories. The tracking system of LVD, an underground experiment to study muons and nutrino astronomy, will use roughly 15000 limited streamer chambers and 100000 external pickup strips with digital readout electronics. In the article the different aspects of chamber operation that serve to establish a testing procedure and to define acceptance criteria for selecting reliable and long-life devices, are discussed. The procedures and the results obtained from a long-term test to evaluate streamer chamber quality, based upon a sample of 2900 items, are described. The selection tests and the long-term observations have been performed in the ASTRA laboratory, established at the Laboratori Nazionali di Frascati to carry out quality control procedures for streamer chambers on a large scale and in a controlled environment

  1. Chest X-ray quality in the diagnosis of pneumonia in children: from prescription to optimization

    International Nuclear Information System (INIS)

    Estevan, M.; Cotelo, E.; Hortal, M.; Iraola, I.

    2008-01-01

    Acute lower respiratory tract infection (ALRI), primarily pneumonia, is the leading cause of childhood death in developing countries. The increasing incidence of antimicrobial resistance and the high cost of vaccines lead to considering the first strategy to reduce pneumonia deaths the early detection of the disease. Case management begins with the clinical examination and may continue with the prescription of a chest x-ray. Consequently, the radiograph should meet quality standards, and radiologists and paediatricians must know how to interpret the images. Special attention should be paid on patient dose due to children radiosensitivity, high frequency and chest x rays rejection rate. This paper is a retrospective study of chest radiographs performed in 5731 children with clinical diagnosis of ALRI assisted in three Uruguayan hospitals during the three year investigation supported by the Division of Vaccines and Immunization of the Pan American Health Organization (PAHO) that had the aim of estimating the burden of pneumonia (from 2001 to 2004). It is analyzed the prescription of radiographs during the diagnosis and in later controls (2220 children assisted in two of the three hospitals). Patient doses are estimated from technical parameters and equipment specifications. The investigation also analyzes patient doses that could have been avoided if paediatricians had managed the disease according to the established protocols. Results show that 82.4 % of chest X-rays diagnosed pneumonia and that some children underwent up to ten radiographs. Significant differences were found in patient dose in the three hospitals, concluding that education on image quality on chest radiographs of radiologists, paediatricians and radiological technologists is the first and best tool for the earlier diagnosis of pneumonia in children and for the application of Radiation Protection (RP) principles in medical exposures. (author)

  2. Balloon test project: Cosmic Ray Antimatter Calorimeter (CRAC)

    Science.gov (United States)

    Christy, J. C.; Dhenain, G.; Goret, P.; Jorand, J.; Masse, P.; Mestreau, P.; Petrou, N.; Robin, A.

    1984-01-01

    Cosmic ray observations from balloon flights are discussed. The cosmic ray antimatter calorimeter (CRAC) experiment attempts to measure the flux of antimatter in the 200-600 Mev/m energy range and the isotopes of light elements between 600 and 1,000 Mev/m.

  3. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    International Nuclear Information System (INIS)

    Cha, Bo Kyung; Jeon, Seongchae; Seo, Chang-Woo

    2016-01-01

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd_2O_2S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  4. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Bo Kyung, E-mail: goldrain99@kaist.ac.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiological Science, Yonsei University, Gangwon-do 220-710 (Korea, Republic of)

    2016-09-21

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  5. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  6. Higher Quality of Molecular Testing, an Unfulfilled Priority: Results from External Quality Assessment for KRAS Mutation Testing in Colorectal Cancer

    NARCIS (Netherlands)

    Tembuyser, L.; Ligtenberg, M.J.L.; Normanno, N.; Delen, S.; Krieken, J.H.J.M. van; Dequeker, E.M.

    2014-01-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European

  7. Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program

    International Nuclear Information System (INIS)

    2002-01-01

    The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase 'gas generationtesting' shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

  8. Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

    Energy Technology Data Exchange (ETDEWEB)

    Busby, Jeremy T [ORNL

    2009-05-01

    The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded

  9. Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

    International Nuclear Information System (INIS)

    Busby, Jeremy T.

    2009-01-01

    The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded

  10. A contribution of quality assurance in veterinary radiography: further development and calibration of a test phantom to control the radiographic quality of X-rays of the equine hock joint

    International Nuclear Information System (INIS)

    Grohmann, D.

    1996-10-01

    The test phantom, which was elaborated by PARISOT (1988), was further developed and calibrated for the equine hock joint. As bigger bone layers had to be radiated, in comparison with the already existing calibration, a new material with higher radiographic density was used for the construction of a new test phantom. A copper test phantom, constructed like a staircase, containing drill-holes in the bottom plate, was used. This practical test phantom, on the highest step only 2.3 mm thick, should prove to be small enough to suit to the daily use in the equine practice. The photographs of each of the views were judged by a specialist in equine medicine and classified into three groups with the criteria 'too light', 'good' and 'too dark'. Then 15 test subjects determined the upper limit of the visibility of the two drillings. After statistical analysis of the data, standard ranges for the three photographing directions were fixed and nomograms were made. As a result of simultaneous photographing of the test phantom and the hock joint of interest, the observer is able to assess the quality of the radiograph. Determining the upper limit of visibility of the holes in the staircase, he can judge the photograph as suitable, too light or too dark for diagnostic use. (author)

  11. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  12. Rootstock effects on fruit quality among 'Ray Ruby' grapefruit trees grown in the Indian River district of Florida

    Science.gov (United States)

    The objective of this experiment was to compare fruit quality parameters of ‘Ray Ruby’ grapefruit grown on seven rootstocks. Four recent releases from the USDA rootstock breeding program, US-852, US-897, US-942 and US-812 (all Citrus reticulata x P. trifoliata hybrids), X639 (C. reticulata x P. tri...

  13. Hybrid GPU-CPU adaptive precision ray-triangle intersection tests for robust high-performance GPU dosimetry computations

    International Nuclear Information System (INIS)

    Perrotte, Lancelot; Bodin, Bruno; Chodorge, Laurent

    2011-01-01

    Before an intervention on a nuclear site, it is essential to study different scenarios to identify the less dangerous one for the operator. Therefore, it is mandatory to dispose of an efficient dosimetry simulation code with accurate results. One classical method in radiation protection is the straight-line attenuation method with build-up factors. In the case of 3D industrial scenes composed of meshes, the computation cost resides in the fast computation of all of the intersections between the rays and the triangles of the scene. Efficient GPU algorithms have already been proposed, that enable dosimetry calculation for a huge scene (800000 rays, 800000 triangles) in a fraction of second. But these algorithms are not robust: because of the rounding caused by floating-point arithmetic, the numerical results of the ray-triangle intersection tests can differ from the expected mathematical results. In worst case scenario, this can lead to a computed dose rate dramatically inferior to the real dose rate to which the operator is exposed. In this paper, we present a hybrid GPU-CPU algorithm to manage adaptive precision floating-point arithmetic. This algorithm allows robust ray-triangle intersection tests, with very small loss of performance (less than 5 % overhead), and without any need for scene-dependent tuning. (author)

  14. Evaluation of differences in quality of experience features for test stimuli of good-only and bad-only overall audiovisual quality

    Science.gov (United States)

    Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith

    2013-01-01

    Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.

  15. Characteristics of a new non-invasive X-ray output analyzer

    International Nuclear Information System (INIS)

    Shinohara, Fuminori; Ishikawa, Mitsuo; Miyazaki, Shigeru

    2002-01-01

    The X-ray systems study group used the Victoreen NERO mAx model 8000, a new non-invasive X-ray output analyzer, to measure the tube voltage, tube voltage waveform, tube current, and irradiation time for conditions corresponding to general radiography and mammography. The measurement results were then compared with those obtained using a conventional invasive measuring instrument. The peak values of the tube voltage measured by the NERO mAx and the invasive measuring instrument were compared. The NERO mAx had a good measurement error range of -1.2 to +0.9 kV. For tube current measurement by the NERO mAx, the maximum error for general radiography conditions was +11 mA and that for mammography conditions was +6 mA. For irradiation time measurement, the value for general radiography conditions was slightly greater and the value for mammography conditions was slightly less than the corresponding values obtained by the invasive measuring instrument. If radiation quality is changed during measurement of the characteristics, measurement values change. Since the NERO mAx incorporates two types of X-ray detectors, it shows good measurement reproducibility. The NERO mAx has been shown to have suitable characteristics for use as a measuring instrument for constancy tests. In the future, constancy tests should be used to quantitatively control the factors determining clinical image quality. (author)

  16. Swift pointing and gravitational-wave bursts from gamma-ray burst events

    International Nuclear Information System (INIS)

    Sutton, Patrick J; Finn, Lee Samuel; Krishnan, Badri

    2003-01-01

    The currently accepted model for gamma-ray burst phenomena involves the violent formation of a rapidly rotating solar-mass black hole. Gravitational waves should be associated with the black-hole formation, and their detection would permit this model to be tested. Even upper limits on the gravitational-wave strength associated with gamma-ray bursts could constrain the gamma-ray burst model. This requires joint observations of gamma-ray burst events with gravitational and gamma-ray detectors. Here we examine how the quality of an upper limit on the gravitational-wave strength associated with gamma-ray bursts depends on the relative orientation of the gamma-ray-burst and gravitational-wave detectors, and apply our results to the particular case of the Swift Burst-Alert Telescope (BAT) and the LIGO gravitational-wave detectors. A result of this investigation is a science-based 'figure of merit' that can be used, together with other mission constraints, to optimize the pointing of the Swift telescope for the detection of gravitational waves associated with gamma-ray bursts

  17. Quality and use of consumer information provided with home test kits: room for improvement.

    Science.gov (United States)

    Grispen, Janaica E J; Ickenroth, Martine H P; de Vries, Nanne K; van der Weijden, Trudy; Ronda, Gaby

    2014-10-01

    Diagnostic self-tests (tests on body materials that are initiated by consumers with the aim of diagnosing a disorder or risk factor) are becoming increasingly available. Although the pros and cons of self-testing are currently not clear, it is an existing phenomenon that is likely to gain further popularity. To examine consumers' use of and needs for information about self-testing, and to assess the quality of consumer information provided with home test kits, as perceived by consumers and as assessed using a checklist of quality criteria. A cross-sectional Internet survey among 305 self-testers assessed their use of and needs for information and their perception of the quality of consumer information provided with self-test kits. A meta-search engine was used to identify Dutch and English consumer information for home diagnostic tests available online at the time of the study. The quality of this consumer information was evaluated using a checklist of quality criteria. The consumers' information needs were in line with the most frequently used information, and the information was perceived as being of moderate to good quality. The information was mostly in agreement with clinical practice guidelines, although information on reliability and follow-up behaviour was limited. Approximately half of the instruction leaflets did not include information on the target group of the test. Although generally of moderate to good quality, some aspects of the information provided were in many cases insufficient. European legislation concerning self-tests and accompanying information needs to be adapted and adhered to more closely. © 2012 John Wiley & Sons Ltd.

  18. Quality of HIV laboratory testing in Tanzania: a situation analysis ...

    African Journals Online (AJOL)

    December 2004 to February 2005 in 12 laboratories which were conveniently selected to represent all the zones of Tanzania. The questionnaires comprised of questions on laboratory particulars, internal and external quality control for HIV testing and quality control of reagents. Source and level of customer satisfaction of ...

  19. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray Departments, four draft standards on specific topics, seven more documents are in advanced stage, and several others under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform tests and interpret results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standards produced so far, with emphasis on physical parameters of diagnostic X-ray installations and proposed criteria for satisfactory performance. (author)

  20. Underground Test Area Quality Assurance Project Plan Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Irene Farnham

    2011-05-01

    This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurance Project Plan, Nevada Test Site, Nevada, Revision 4.

  1. Quality control of mammography

    International Nuclear Information System (INIS)

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  2. Radiation doses and some aspects of image quality in mammography facilities in New Zealand

    International Nuclear Information System (INIS)

    Williamson, B.D.P.; Poletti, J.L.

    1990-02-01

    Until recently, mammography in New Zealand was performed largely with adapted conventional x-ray machines with tungsten anode x-ray tubes. Over the last several years these have virtually all been replaced by dedicated mammography machines with molybdenum anode x-ray tubes. To assess current trends in radiation doses to patients and central aspects of image quality, some 37 mammography x-ray machines were surveyed during 1988-89. The mean glandular dose per film for 30 and 45 mm thick breast-equivalent phantoms was determined using thermoluminescent dosimetry. Imagings of simulated microcalcifications (specks) and a contrast-detail phantom were assessed. Accuracy of calibration of the x-ray machines and quality of film processing were also tested. Details of the survey results are given. Mean glandular tissue doses per cranio-caudal films were generally well within the recommended guidelines. Mammography facilities differed in their ability to delete simulated calcification specks. Mammographic equipment was found to be generally well adjusted. Speed and contrast of film processing were found to vary widely implying that this is a major cause of the variations in dose and image quality. An annex outlines a quality assurance programme for maintenance of optimal physical image quality and control of radiation doses. 55 refs., 21 tabs., 17 figs., 2 ills

  3. New trends in space x-ray optics

    Science.gov (United States)

    Hudec, R.; Maršíková, V.; Pína, L.; Inneman, A.; Skulinová, M.

    2017-11-01

    The X-ray optics is a key element of various X-ray telescopes, X-ray microscopes, as well as other X-ray imaging instruments. The grazing incidence X-ray lenses represent the important class of X-ray optics. Most of grazing incidence (reflective) X-ray imaging systems used in astronomy but also in other (laboratory) applications are based on the Wolter 1 (or modified) arrangement. But there are also other designs and configurations proposed, used and considered for future applications both in space and in laboratory. The Kirkpatrick-Baez (K-B) lenses as well as various types of Lobster-Eye optics and MCP/Micropore optics serve as an example. Analogously to Wolter lenses, the X-rays are mostly reflected twice in these systems to create focal images. Various future projects in X-ray astronomy and astrophysics will require large segments with multiple thin shells or foils. The large Kirkpatrick-Baez modules, as well as the large Lobster-Eye X-ray telescope modules in Schmidt arrangement may serve as examples. All these space projects will require high quality and light segmented shells (bent or flat foils) with high X-ray reflectivity and excellent mechanical stability. The Multi Foil Optics (MFO) approach represent a promising alternative for both LE and K-B X-ray optical modules. Several types of reflecting substrates may be considered for these applications, with emphasis on thin float glass sheets and, more recently, high quality silicon wafers. This confirms the importance of non- Wolter X-ray optics designs for the future. Future large space X-ray telescopes (such as IXO) require precise and light-weight X-ray optics based on numerous thin reflecting shells. Novel approaches and advanced technologies are to be exploited and developed. In this contribution, we refer on results of tested X-ray mirror shells produced by glass thermal forming (GTF) and by shaping Si wafers. Both glass foils and Si wafers are commercially available, have excellent surface

  4. Design and Initial Tests of the Tracker-Converter ofthe Gamma-ray Large Area Space Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, W.B.; Bagagli, R.; Baldini, L.; Bellazzini, R.; Barbiellini, G.; Belli, F.; Borden, T.; Brez, A.; Brigida, M.; Caliandro, G.A.; Cecchi, C.; Cohen-Tanugi, J.; De; Drell, P.; Favuzzi, C.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Germani, S.; Giannitrapani, R.; Giglietto, N.; /UC, Santa Cruz /INFN, Pisa /Pisa U. /INFN, Trieste /INFN,

    2007-04-16

    The Tracker subsystem of the Large Area Telescope (LAT) science instrument of the Gamma-ray Large Area Space Telescope (GLAST) mission has been completed and tested. It is the central detector subsystem of the LAT and serves both to convert an incident gamma-ray into an electron-positron pair and to track the pair in order to measure the gamma-ray direction. It also provides the principal trigger for the LAT. The Tracker uses silicon strip detectors, read out by custom electronics, to detect charged particles. The detectors and electronics are packaged, along with tungsten converter foils, in 16 modular, high-precision carbon-composite structures. It is the largest silicon-strip detector system ever built for launch into space, and its aggressive design emphasizes very low power consumption, passive cooling, low noise, high efficiency, minimal dead area, and a structure that is highly transparent to charged particles. The test program has demonstrated that the system meets or surpasses all of its performance specifications as well as environmental requirements. It is now installed in the completed LAT, which is being prepared for launch in early 2008.

  5. Quality assurance procedure for a gamma guided stereotactic breast biopsy system.

    Science.gov (United States)

    Welch, Benjamin L; Brem, Rachel; Black, Rachel; Majewski, Stan

    2006-01-01

    A quality assurance procedure has been developed for a prototype gamma-ray guided stereotactic biopsy system. The system consists of a compact small-field-of-view gamma-ray camera mounted to the rotational arm of a Lorad stereotactic biopsy system. The small-field-of-view gamma-ray camera has been developed for clinical applications where mammographic X-ray localization is not possible. Marker sources that can be imaged with the gamma-camera have been designed and built for quality assurance testing and to provide a fiducial reference mark. An algorithm for determining the three dimensional location of a region of interest, such as a lesion, relative to the fiducial mark has been implemented into the software control of the camera. This system can be used to determine the three-dimensional location of a region of interest from a stereo pair of images and that information can be used to guide a biopsy needle to that site. Point source phantom tests performed with the system have demonstrated that the camera can be used to localize a point of interest to within 1 mm, which is satisfactory for its use in needle localization.

  6. Development of industrial x-ray computed tomography and its application to refractories

    International Nuclear Information System (INIS)

    Aiba, Yoshiro; Oki, Kazuo; Nakamura, Shigeo; Fujii, Masashi.

    1985-01-01

    An industrial X-ray computed tomography was developed under the influence of the rapid spread of the use of the X-ray CT scanner in the medical field and improvements of the equipment. Although current nondestructive testing machines of refractories use the ultrasonic inspection method or the X-ray fluoroscopic method, these equipments cannot produce a tomogram or cannot carry out quantitative evaluation. By using an industrial X-ray computed tomography, submerged nozzles for continuous casting of steel were analyzed with interesting results. The features of the industrial X-ray computed tomography applied for refractory nozzles are as follows: (1) It promptly detects interior defects. (2) It can measure dimensions and shapes. (3) It can numerically express the distribution of density. Accordingly, it is expected that the industrial X-ray computed tomography will widely be used in the fields of development and quality control of refractories and advanced ceramic materials. (author)

  7. Test plan for demonstration of Rapid Transuranic Monitoring Laboratory

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1993-06-01

    This plan describes tests to demonstrate the capability of the Rapid Transuranic Monitoring Laboratory (RTML) to monitor airborne alpha-emitting radionuclides and analyze soil, smear, and filter samples for alpha- and gamma-emitting radionuclides under field conditions. The RTML will be tested during June 1993 at a site adjacent to the Cold Test Pit at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. Measurement systems installed in the RTML that will be demonstrated include two large-area ionization chamber alpha spectrometers, an x-ray/gamma-ray spectrometer, and four alpha continuous air monitors. Test objectives, requirements for data quality, experimental apparatus and procedures, and safety and logistics issues are described

  8. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Constancy tests and quality assurance of the activimeters used in a radiopharmaceutical production unit

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo M.G.; Mamede, Marcelo; Ferreira, Andréa V.; Nascimento, Leonardo T.C.; Costa, Flávia M.; Silva, Juliana B.

    2017-01-01

    Activimeters (or dose calibrators) are essential instruments to verify activity of radiopharmaceutical after production and also before the dose administration in humans or animals for molecular imaging. The efficiency and safety measurements depend on, beside other factors, constancy tests and quality assurance. Thereby, the aim of this work was to perform constancy tests and quality assurance in the activimeters of the UPPR/CDTN, based on the CNEN-NN 3.05 Brazilian standard and the manufacturer's manual. Physical inspection, auto zero, background check, camera voltage, data check and constancy test were done. In addition, accuracy and precision tests were performed using a set of standard certified radioactive sources ( 57 Co, 133 Ba and 137 Cs), according to the CNEN NN 3.05 Brazilian standard. Linearity test was also performed to evaluate the response of the equipment in over the entire range of activities used in routine. The equipment are periodically submitted to the quality control tests and the results were compared. After performing the proposed tests it is possible to conclude that activimeters are in accordance with the requirements of the CNEN standard and manufacturer's manual. A quality control checklist was prepared to guide users and to record the results of quality assurance testing to monitor the equipment performance. This initiative is part of the quality assurance program implemented at UPPR. (author)

  10. Constancy tests and quality assurance of the activimeters used in a radiopharmaceutical production unit

    Energy Technology Data Exchange (ETDEWEB)

    Gontijo, Rodrigo M.G.; Mamede, Marcelo [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Ferreira, Andréa V.; Nascimento, Leonardo T.C.; Costa, Flávia M.; Silva, Juliana B., E-mail: rodrigo.gontijo@cdtn.br, E-mail: mamede.mm@gmail.com [Universidade Federal de Minas Gerais (IMA/FM/UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem

    2017-07-01

    Activimeters (or dose calibrators) are essential instruments to verify activity of radiopharmaceutical after production and also before the dose administration in humans or animals for molecular imaging. The efficiency and safety measurements depend on, beside other factors, constancy tests and quality assurance. Thereby, the aim of this work was to perform constancy tests and quality assurance in the activimeters of the UPPR/CDTN, based on the CNEN-NN 3.05 Brazilian standard and the manufacturer's manual. Physical inspection, auto zero, background check, camera voltage, data check and constancy test were done. In addition, accuracy and precision tests were performed using a set of standard certified radioactive sources ({sup 57}Co, {sup 133}Ba and {sup 137}Cs), according to the CNEN NN 3.05 Brazilian standard. Linearity test was also performed to evaluate the response of the equipment in over the entire range of activities used in routine. The equipment are periodically submitted to the quality control tests and the results were compared. After performing the proposed tests it is possible to conclude that activimeters are in accordance with the requirements of the CNEN standard and manufacturer's manual. A quality control checklist was prepared to guide users and to record the results of quality assurance testing to monitor the equipment performance. This initiative is part of the quality assurance program implemented at UPPR. (author)

  11. Quality control of diagnostic X-ray installations for conventional radiography in the period of their clinical use-methods and results of their implementation

    International Nuclear Information System (INIS)

    Vassileva, J.

    2000-01-01

    A guide on the qualify assurance in x-ray diagnostics, developed for Bulgarian medical physicists and other specialists is presented. All measurement described have been testing for three years in the Department of Radiology in the Regional Hospital in Shoumen. The guide covers only tests on the x-ray equipment. A list of test measurements as well as recommendations for the minimum frequency of a routine performance testing are given

  12. Rules of thumb to increase the software quality through testing

    Science.gov (United States)

    Buttu, M.; Bartolini, M.; Migoni, C.; Orlati, A.; Poppi, S.; Righini, S.

    2016-07-01

    The software maintenance typically requires 40-80% of the overall project costs, and this considerable variability mostly depends on the software internal quality: the more the software is designed and implemented to constantly welcome new changes, the lower will be the maintenance costs. The internal quality is typically enforced through testing, which in turn also affects the development and maintenance costs. This is the reason why testing methodologies have become a major concern for any company that builds - or is involved in building - software. Although there is no testing approach that suits all contexts, we infer some general guidelines learned during the Development of the Italian Single-dish COntrol System (DISCOS), which is a project aimed at producing the control software for the three INAF radio telescopes (the Medicina and Noto dishes, and the newly-built SRT). These guidelines concern both the development and the maintenance phases, and their ultimate goal is to maximize the DISCOS software quality through a Behavior-Driven Development (BDD) workflow beside a continuous delivery pipeline. We consider different topics and patterns; they involve the proper apportion of the tests (from end-to-end to low-level tests), the choice between hardware simulators and mockers, why and how to apply TDD and the dependency injection to increase the test coverage, the emerging technologies available for test isolation, bug fixing, how to protect the system from the external resources changes (firmware updating, hardware substitution, etc.) and, eventually, how to accomplish BDD starting from functional tests and going through integration and unit tests. We discuss pros and cons of each solution and point out the motivations of our choices either as a general rule or narrowed in the context of the DISCOS project.

  13. A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gianoncelli, Alessandra, E-mail: alessandra.gianoncelli@elettra.eu [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bufon, Jernej [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Ahangarianabhari, Mahdi [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Altissimo, Matteo [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bellutti, Pierluigi [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Bertuccio, Giuseppe [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Borghes, Roberto [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Carrato, Sergio [University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Cautero, Giuseppe [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Fabiani, Sergio [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Giacomini, Gabriele [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Giuressi, Dario [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Kourousias, George [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Menk, Ralf Hendrik [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Picciotto, Antonino; Piemonte, Claudio [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Rachevski, Alexandre [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); and others

    2016-04-21

    The last decades have witnessed substantial efforts in the development of several detector technologies for X-ray fluorescence (XRF) applications. In spite of the increasing trend towards performing, cost-effective and reliable XRF systems, detectors for soft X-ray spectroscopy still remain a challenge, requiring further study, engineering and customization in order to yield effective and efficient systems. In this paper we report on the development, first characterization and tests of a novel multielement detector system based on low leakage current silicon drift detectors (SDD) coupled to ultra low noise custom CMOS preamplifiers for synchrotron-based low energy XRF. This new system exhibits the potential for improving the count rate by at least an order of magnitude resulting in ten-fold shorter dwell time at an energy resolution similar to that of single element silicon drift detectors.

  14. XRF Newsletter, No. 25, September 2013 [X Ray Fluorescence in the IAEA and its Member States

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-02-15

    One of the main missions of any analytical laboratory is the provision of reliable results. Many X-ray fluorescence laboratories in the International Atomic Energy Agency (IAEA) Member States (MSs) carry out research aimed at improving the performance and extending the applicability of various X-ray based techniques. The IAEA assists its MSs Laboratories to maintain their readiness by producing reference materials, by developing standardized analytical methods and by conducting interlaboratory comparisons and proficiency tests as tools for quality control. To achieve this aim and ensure a reliable worldwide, rapid and consistent response, the IAEA Nuclear Science and Instrumentation Laboratory (NSIL) organizes proficiency tests annually for X-ray spectrometry laboratories. The main objective of these tests is to enhance the capability of interested MSs in effective utilization of nuclear spectrometry and analytical services in industry, human health, agriculture, and in monitoring and evaluation of environmental pollution. Indeed, proficiency tests are designed to identify analytical problems, to support IAEA MSs laboratories to improve the quality of their analytical results, to maintain their accreditation and to provide a regular forum for discussion and technology transfer in this area. The type of samples and the concentration levels of the analytes are designed and chosen in a way to better enable identification of potential analytical problems. Since 2001, the NSIL has organized nine proficiency test exercises (PTXRFIAEA)

  15. Quality testing as a reserve for rationalization measures

    International Nuclear Information System (INIS)

    Babic, H.G.

    1979-01-01

    The increase in large-scale planning activities and their realization in all fields of quality testing as opposed to the requirements for a reduction of costs emphasizes the necessity of rationaling measures. Especially during the planning phases there are a number of possibilities for solving this problem: the determination of reference dates for production devices based on the preparation of dates with regard to machines and testing, the assignment of the testing frequency in dependence of the quotient from deviations in production and characteristics tolerances, the application of methods of operation planning following different priority rules. Apart from already existing systems for normal and computeraided planning of testing material application by the help of which the most optimal testing material is selected for certain testing jobs systematic representations and programs for the planning of the testing procedure and the testing precision will enrich the joint complex of the organization of testing procedures. (orig./RW) [de

  16. Analysis of factors affecting the LOCA test quality

    International Nuclear Information System (INIS)

    Wang Lu

    2008-01-01

    Localization of nuclear safety-related equipment has become an important way of nuclear power development in China. To meet this demand, the competence should be promoted in the following two areas, one is to develop the capability of R and D and manufacturing of nuclear safety-related equipment, the other is to implement equipment qualification according to relevant codes and standards. As LOCA test is one of the most important parts in the qualification test of nuclear safety-related equipment, the main factors related with the quality of the LOCA test are analyzed in this paper, and this may be a reference to improve the skills in designing, constructing and operating LOCA test devices. (authors)

  17. Femtosecond X-ray Absorption Spectroscopy at a Hard X-ray Free Electron Laser

    DEFF Research Database (Denmark)

    Lemke, Henrik T.; Bressler, Christian; Chen, Lin X.

    2013-01-01

    X-ray free electron lasers (XFELs) deliver short (current (SASE based) XFELs, they can be used for measuring high......-quality X-ray absorption data and we report femtosecond time-resolved X-ray absorption near-edge spectroscopy (XANES) measurements of a spin-crossover system, iron(II) tris(2,2'-bipyridine) in water. The data indicate that the low-spin to high-spin transition can be modeled by single-exponential kinetics...

  18. X-ray image intensifier for cardiovascular diagnosis. Development of RTP 9203 B-P4 and evaluation of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Obata, Y; Suzuki, A; Noji, T; Harao, N [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1979-07-01

    The high utility of 35-mm cine fluorography with high-quality X-ray image intensifier has recently been acknowledged in the field of cardiovascular diagnosis. The newly developed 9-inch dual-field X-ray image intensifier is particularly suitable for 35-mm cinefluorography. The main characteristics of this tube are the increased contrast, brightness and resolution of images and the reduced quantum noise. These characteristics are caused by the CsI input phosphor screen which has a ''light-guide effect'', a high-sensitivity photocathode and a dark output screen. The tube is equipped with a high-voltage power supply with high reliability.

  19. Characterization of a Test for Invasive Breast Cancer Using X-ray Diffraction of Hair - Results of a Clinical Trial

    Directory of Open Access Journals (Sweden)

    Gary L. Corino

    2009-11-01

    Full Text Available Objective: To assess the performance of a test for breast cancer utilizing synchrotron x-ray diffraction analysis of scalp hair from women undergoing diagnostic radiology assessment. Design and Setting: A double-blinded clinical trial of women who attended diagnostic radiology clinics in Australia. Patients: 1796 women referred for diagnostic radiology, with no previous history of cancer. Main Outcome Measures: Sensitivity, specificity and accuracy of the hair test analysis compared to the gold standard of imaging followed by biopsy where indicated. Results: The hair-based assay had an overall accuracy of >77% and a negative predictive value of 99%. For all women, the sensitivity of both mammography and x-ray diffraction alone was 64%, but when used together the sensitivity rose to 86%. The sensitivity of the hair test for women under the age of 70 was 74%. Conclusion: In this large population trial the association between the presence of breast cancer and an altered hair fibre X-ray diffraction pattern previously reported has been confirmed. It appears that mammography and X-ray diffraction of hair detect different populations of breast cancers, and are synergistic when used together.

  20. The measurement test of uranium in a uranium-contaminated waste by passive gamma-rays measurement method

    CERN Document Server

    Sukegawa, Y; Ohki, K; Suzuki, S; Yoshida, M

    2002-01-01

    This report is completed about the measurement test and the proofreading of passive gamma - rays measurement method for Non - destructive assay of uranium in a uranium-contaminated waste. The following are the results of the test. 1) The estimation of the amount of uranium by ionization survey meter is difficult for low intensity of gamma-rays emitted from uranium under about 50g. 2) The estimation of the amount of uranium in the waste by NaI detector is possible in case of only uranium, but the estimation from mixed spectrums with transmission source (60-cobalt) is difficult to confirm target peaks. 3) If daughter nuclides of uranium and thorium chain of uranium ore exist, measurement by NaI detector is affected by gamma-rays from the daughter nuclides seriously-As a result, the estimation of the amount of uranium is difficult. 4) The measurement of uranium in a uranium-contaminated waste by germanium detector is possible to estimate of uranium and other nuclides. 5) As to estimation of the amount of uranium...

  1. Comparison of the performance of intraoral X-ray sensors using objective image quality assessment.

    Science.gov (United States)

    Hellén-Halme, Kristina; Johansson, Curt; Nilsson, Mats

    2016-05-01

    The main aim of this study was to evaluate the performance of 10 individual sensors of the same make, using objective measures of key image quality parameters. A further aim was to compare 8 brands of sensors. Ten new sensors of 8 different models from 6 manufacturers (i.e., 80 sensors) were included in the study. All sensors were exposed in a standardized way using an X-ray tube voltage of 60 kVp and different exposure times. Sensor response, noise, low-contrast resolution, spatial resolution and uniformity were measured. Individual differences between sensors of the same brand were surprisingly large in some cases. There were clear differences in the characteristics of the different brands of sensors. The largest variations were found for individual sensor response for some of the brands studied. Also, noise level and low contrast resolution showed large variations between brands. Sensors, even of the same brand, vary significantly in their quality. It is thus valuable to establish action levels for the acceptance of newly delivered sensors and to use objective image quality control for commissioning purposes and periodic checks to ensure high performance of individual digital sensors. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Influence of imaging factors on image quality in bovine computed radiography (CR) using portable X-ray equipment

    International Nuclear Information System (INIS)

    Kishimoto, M.; Sumiya, T.; Lee, K.J.

    2010-01-01

    The purpose of this study was to investigate the effect of X-ray tube-cassette distance and image scanning time on image quality to establish the benefit of Computed Radiography (CR) in bovine clinical practice. The tube-cassette distance had no effect on the visual evaluation score (graininess and sharpness). The image scanning time correlated with graininess but not sharpness. From these results, it was concluded that accidental variations in the tube-cassette distance and variations in image scanning time of several hours will not be major problems in clinical practice. CR is considered a useful X-ray system in bovine clinical imaging in which the maintenance of reproducible tube-cassette distance is difficult and variations in image scanning time is assumed

  3. Design of a prototype tri-electrode ion-chamber for megavoltage X-ray imaging

    International Nuclear Information System (INIS)

    Samant, Sanjiv S.; Gopal, Arun; Jain, Jinesh; Xia Junyi; DiBianca, Frank A.

    2007-01-01

    High-energy (megavoltage) X-ray imaging is widely used in industry (e.g., aerospace, construction, material sciences) as well as in health care (radiation therapy). One of the fundamental problems with megavoltage imaging is poor contrast and spatial resolution in the detected images due to the dominance of Compton scattering at megavoltage X-ray energies. Therefore, although megavoltage X-rays can be used to image highly attenuating objects that cannot be imaged at kilovoltage energies, the former does not provide the high image quality that is associated with the latter. A high contrast and spatial resolution detector for high-energy X-ray fields called the kinestatic charge detector (KCD) is presented here. The KCD is a tri-electrode ion-chamber based on highly pressurized noble gas. The KCD operates in conjunction with a strip-collimated X-ray beam (for high scatter rejection) to scan across the imaging field. Its thick detector design and unique operating principle provides enhanced charge signal integration for high quality imaging (quantum efficiency ∼50%) despite the unfavorable implications of high-energy X-ray interactions on image quality. The proposed design for a large-field prototype KCD includes a cylindrical pressure chamber along with 576 signal-collecting electrodes capable of resolving at 2 mm -1 . The collecting electrodes are routed out of the chamber through the flat end-cap, thereby optimizing the mechanical strength of the chamber. This article highlights the simplified design of the chamber using minimal components for simple assembly. In addition, fundamental imaging measurements and estimates of ion recombination that were performed on a proof-of-principle test chamber are presented. The imaging performance of the prototype KCD was found to be an order-of-magnitude greater than commercial phosphor screen based flat-panel systems, demonstrating the potential for high-quality megavoltage imaging for a variety of industrial applications

  4. Detection of ultraviolet Cherenkov light from high energy cosmic ray atmospheric showers: A field test

    International Nuclear Information System (INIS)

    Bartoli, B.; Peruzzo, L.; Sartori, G.; Bedeschi, F.; Bertolucci, E.; Mariotti, M.; Menzione, A.; Ristori, L.; Stefanini, A.; Zetti, F.; Scribano, A.; Budinich, M.; Liello, F.

    1991-01-01

    We present the results of a test with a prototype apparatus aimed to detect the ultraviolet Cherenkov light in the wavelenght range 2000-2300A, emitted by high energy cosmic ray showers. The system consists of a gas proportional chamber, with TMAE vapour as the photosensitive element, placed on the focal plane of a 1.5 m diameter parabolic mirror. The test was done during the summer of 1989 with cosmic ray showers seen in coincidence with the EAS-TOP experiment, an extended atmospheric shower charged particle array now being exploited at Campo Imperatore, 1900 m above sea level, on top of the Gran Sasso underground Laboratory of INFN. The results were positive and show that a full scale ultraviolet Cherenkov experiment with good sensitivity, angular resolution and virtually no background from moonlight or even daylight can be envisaged. (orig.)

  5. Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    Science.gov (United States)

    Anvari, Akbar; Poirier, Yannick; Sawant, Amit

    2018-04-28

    , with maximum differences ≤3% for ionization chamber and ≤1.7% for Gafchromic EBT3 dosimetry film, respectively. We have shown that the EPID response is linear with tube current (mA) for the entire range of tube kilovoltage peak. Notably, a close relationship was seen between the detector response vs mA slope, and the kilovoltage peak, allowing an independent verification of kilovoltage peak stability based solely on EPID response. In addition to dosimetry tests, according to the beam-targeting measurement using portal images, maximum displacement of the central axis of the x-ray beam (due to sag) was 0.76 ± 0.09 mm at gantry 135°/couch 0° and 0.89 ± 0.06 mm at gantry 0°/couch -135°. We performed the first comprehensive analysis on the dosimetric properties of an EPID operating at kilovoltage x-ray energies. We characterized the detector performance over a 11-month period. Our results indicate that the imager is a stable and convenient tool for SARRP routine QA tests. We then developed EPID-based tests to perform routine SA-IGRT systems QA tasks, such as verifying constancy of beam quality, energy, output, and profile measurements, relative output factors, and beam targeting. © 2018 American Association of Physicists in Medicine.

  6. X-ray irradiation on blood products for the purpose of prevention of PT-GVHD

    International Nuclear Information System (INIS)

    Tayama, Tatsuya; Naohara, Tooru; Haneda, Kenji; Juji, Takeo.

    1990-01-01

    X-ray irradiation on blood products is a common method to prevent the risk of inducing PT-GVHD, and has recently become to be used in Japan. We have tried X-ray irradiation on WB, CRC and PC using HITACHI X-ray Irradiation Apparatus MBR1520R, and studied its practical usefulness. In case of irradiation on blood bags as the minimum dose of 1,500 rads, these conditions are thought to be practical: 1) the use of 1.0 mm Al filter, 2) the distance of 550 nm from X-ray source, and 3) irradiation on 4 bags at the same time. But, it has also been noticed that total doses and qualities of X-ray absorbed into blood were different between upper and lower side of the bag. Bloods on upper side absorbed much doses and a wide range of X-ray, on the other hand, bloods on lower side absorbed less doses and hard X-ray. In these conditions, irradiated lymphocytes showed a complete inhibition of thymidine uptake in MLC test, still had 15% of activity in PHA stimulation. The qualities of other blood components have not changed before and after irradiation. X-ray irradiation is useful in a routine work of blood center, but problems of proper doses and a uniformity of irradiation are remained to be solved. (author)

  7. Mobile X-ray inspection of light weight materials

    International Nuclear Information System (INIS)

    Ewert, Uwe; Redmer, Bernhard; Raedel, Christoph; Osterloh, Kurt; Schnars, Ulf; Henrich, Rudolf; Schimmelmann, Olaf; Bavendiek, Klaus; Jahn, Mirko

    2008-01-01

    Digital detectors such as phosphor imaging plates (IP) and digital detector arrays (DDA) allow radiographic inspection with higher efficiency and improved image quality in comparison to the classic film technique. Mobile X-ray flash tubes are used routinely for veterinarian and security applications. New high sensitive IPs and DDAs enable to apply them for inspection of light materials with low X-ray attenuation as in aluminium, plastics and composites. A versatile computed tomography (CT) system was developed for in situ inspection of large aircraft components under production conditions. A gate based planar computed tomograph was developed and tested for inspection of integrity of the stringer incorporation. Successful test trials were performed to prove the detection rate of cracks in embedded stringers. Honey comb structures of aircrafts have to be inspected for water inclusions during in-service inspections. Thermography is a powerful method for in house inspections when variations in temperature caused e.g. by sunshine can be excluded. A new X-ray diaphragm was developed for mobile back scatter measurements of large components. This method is insensitive to heat alterations in the field and thus can be applied also outdoors. (orig.)

  8. X-ray testing for short-time dynamic applications; Roentgenuntersuchungen fuer kurzzeitdynamische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried [Fraunhofer-Institut fuer Kurzzeitdynamik, Efringen-Kirchen (Germany). Ernst-Mach-Inst. (EMI)

    2017-08-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  9. Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage

    Science.gov (United States)

    Liu, Tianshuai; Rong, Junyan; Gao, Peng; Zhang, Wenli; Liu, Wenlei; Zhang, Yuanke; Lu, Hongbing

    2018-02-01

    With the advances of x-ray excitable nanophosphors, x-ray luminescence computed tomography (XLCT) has become a promising hybrid imaging modality. In particular, a cone-beam XLCT (CB-XLCT) system has demonstrated its potential in in vivo imaging with the advantage of fast imaging speed over other XLCT systems. Currently, the imaging models of most XLCT systems assume that nanophosphors emit light based on the intensity distribution of x-ray within the object, not completely reflecting the nature of the x-ray excitation process. To improve the imaging quality of CB-XLCT, an imaging model that adopts an excitation model of nanophosphors based on x-ray absorption dosage is proposed in this study. To solve the ill-posed inverse problem, a reconstruction algorithm that combines the adaptive Tikhonov regularization method with the imaging model is implemented for CB-XLCT reconstruction. Numerical simulations and phantom experiments indicate that compared with the traditional forward model based on x-ray intensity, the proposed dose-based model could improve the image quality of CB-XLCT significantly in terms of target shape, localization accuracy, and image contrast. In addition, the proposed model behaves better in distinguishing closer targets, demonstrating its advantage in improving spatial resolution.

  10. Design and image-quality performance of high resolution CMOS-based X-ray imaging detectors for digital mammography

    Science.gov (United States)

    Cha, B. K.; Kim, J. Y.; Kim, Y. J.; Yun, S.; Cho, G.; Kim, H. K.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2012-04-01

    In digital X-ray imaging systems, X-ray imaging detectors based on scintillating screens with electronic devices such as charge-coupled devices (CCDs), thin-film transistors (TFT), complementary metal oxide semiconductor (CMOS) flat panel imagers have been introduced for general radiography, dental, mammography and non-destructive testing (NDT) applications. Recently, a large-area CMOS active-pixel sensor (APS) in combination with scintillation films has been widely used in a variety of digital X-ray imaging applications. We employed a scintillator-based CMOS APS image sensor for high-resolution mammography. In this work, both powder-type Gd2O2S:Tb and a columnar structured CsI:Tl scintillation screens with various thicknesses were fabricated and used as materials to convert X-ray into visible light. These scintillating screens were directly coupled to a CMOS flat panel imager with a 25 × 50 mm2 active area and a 48 μm pixel pitch for high spatial resolution acquisition. We used a W/Al mammographic X-ray source with a 30 kVp energy condition. The imaging characterization of the X-ray detector was measured and analyzed in terms of linearity in incident X-ray dose, modulation transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE).

  11. GESCAL: Quality management automated system for a calibration and test laboratory

    International Nuclear Information System (INIS)

    Manzano de Armas, J.; Valdes Ramos, M.; Morales Monzon, J.A.

    1998-01-01

    GESCAL is a software created to automate all elements composing the quality system in a calibration and test laboratory. It also evaluates quality according to its objectives and policies. This integrated data system decreases considerably the amount of time devoted to manage quality. It is speedier in searching and evaluating information registers thus notably in reducing the workload for laboratory staff

  12. Investigation of the applicability of a special parallel-plate ionization chamber for x-ray beam dosimetry

    International Nuclear Information System (INIS)

    Perini, Ana P.; Neves, Lucio P.; Caldas, Linda V.E.

    2014-01-01

    Diagnostic x-rays are the greatest source of exposition to ionizing radiation of the population worldwide. In order to obtain accurate and lower-cost dosimeters for quality control assurance of medical x-ray facilities, a special ionization chamber was designed at the Calibration Laboratory of the IPEN, for dosimetry in diagnostic radiology beams. For the chamber characterization some tests were undertaken. Monte Carlo simulations were proposed to evaluate the distribution of the deposited energy in the sensitive volume of the ionization chamber and the collecting electrode effect on the chamber response. According to the obtained results, this special ionization chamber presents potential use for dosimetry of conventional diagnostic radiology beams. - Highlights: • An ionization chamber with a novel design was characterized for x-ray beam dosimetry. • This ionization chamber was evaluated in diagnostic radiology qualities. • The characterization tests results were within the recommended limits. • Monte Carlo simulations were employed to evaluate the design of the dosimeter. • The developed prototype is a good alternative for calibration laboratories and clinics

  13. Local gamma ray events as tests of the antimatter theory of gamma ray bursts

    International Nuclear Information System (INIS)

    Sofia, S.; Wilson, R.E.

    1976-01-01

    Nearby examples of the antimatter 'chunks' postulated by Sofia and Van Horn to explain the cosmic gamma ray bursts may produce detectable gamma ray events when struck by solar system meteoroids. These events would have a much shorter time scale and higher energy spectrum than the bursts already observed. In order to have a reasonably high event rate, the local meteoroid population must extend to a distance from the Sun of the order of 0.1 pc, but the required distance could become much lower if the instrumental threshold is improved. The expected gamma ray flux for interaction of the antimatter bodies with the solar wind is also examined, and found to be far below present instrumental capabilities. (Auth.)

  14. Quality assurance for HIV point-of-care testing and treatment monitoring assays

    Science.gov (United States)

    Sandstrom, Paul; Denny, Thomas N.; Hurlston, Mackenzie; Ball, Terry B.; Peeling, Rosanna W.; Boeras, Debrah I.

    2016-01-01

    In 2015, UNAIDS launched the 90-90-90 targets aimed at increasing the number of people infected with HIV to become aware of their status, access antiretroviral therapies and ultimately be virally suppressed. To achieve these goals, countries may need to scale up point-of-care (POC) testing in addition to strengthening central laboratory services. While decentralising testing increases patient access to diagnostics, it presents many challenges with regard to training and assuring the quality of tests and testing. To ensure synergies, the London School of Hygiene & Tropical Medicine held a series of consultations with countries with an interest in quality assurance and their implementing partners, and agreed on an external quality assessment (EQA) programme to ensure reliable results so that the results lead to the best possible care for HIV patients. As a result of the consultations, EQA International was established, bringing together EQA providers and implementers to develop a strategic plan for countries to establish national POC EQA programmes and to estimate the cost of setting up and maintaining the programme. With the dramatic increase in the number of proficiency testing panels required for thousands of POC testing sites across Africa, it is important to facilitate technology transfer from global EQA providers to a network of regional EQA centres in Africa for regional proficiency testing panel production. EQA International will continue to identify robust and cost-effective EQA technologies for quality POC testing, integrating novel technologies to support sustainable country-owned EQA programmes in Africa. PMID:28879133

  15. Assessment of the structural integrity of a prototypical instrumented IFMIF high flux test module rig by fully 3D X-ray microtomography

    Energy Technology Data Exchange (ETDEWEB)

    Tiseanu, Ion [National Institute for Laser, Plasma and Radiation Physics, Plasma Physics and Nuclear Fusion Laboratory NILPRP, P.O. Box MG-36, R-77125 Bucharest-Magurele (Romania)], E-mail: tiseanu@infim.ro; Simon, Martin [Hans Waelischmiller GmbH (HWM), Schiessstattweg 16, D-88677 Markdorf (Germany); Craciunescu, Teddy; Mandache, Bogdan N. [National Institute for Laser, Plasma and Radiation Physics, Plasma Physics and Nuclear Fusion Laboratory NILPRP, P.O. Box MG-36, R-77125 Bucharest-Magurele (Romania); Heinzel, Volker; Stratmanns, Erwin; Simakov, Stanislaw P.; Leichtle, Dieter [Forschungszentrum Karlsruhe (FZK), Institut fuer Reaktorsicherheit IRS, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2007-10-15

    An inspection procedure to assess the mechanical integrity of the International Fusion Materials Irradiation Facility (IFMIF) capsules and rigs during the irradiation campaign is necessary. Due to its penetration ability and contrast mechanism, the X-ray microtomography is the only known tool that could meet these requirements. In the high flux test module (HFTM) of IFMIF miniaturized specimens are densely packed in capsules. The capsules, which wear electric heaters and thermocouples, are housed in rigs. To assure a well-defined thermal contact the heater wires have to be attached to the capsules by brazing them into grooves. The examination of the quality of the braze material layer is of crucial interest in order to assure the best heat coupling of the heater wires to the capsule. A high density of the heaters is necessary to maintain the required temperature and, in addition NaK filling of narrow channels is employed for improving the 3D-heat transfer between the irradiation specimens and the capsule wall. Fully 3D tomographic inspections of a prototypical HFTM instrumented capsule, developed and manufactured at FZK, were conducted. In order to identify the optimum irradiation parameters and scanning configuration we carried out a comparative NDT analysis on two microtomography facilities: a compact, high magnification installation at NILPRP and a high-end industrial tomography facility with higher X-ray energy and intensity at HWM. At optimum inspection parameters of a directional microfocus X-ray source (U = 220 kV and I = 300 {mu}A) the geometry resolution was about 30 microns for characteristic dimension of the sample of 50 mm. Voids of 30 microns diameter and cracks of about 20 microns width can be detected. The absolute error of geometrical measurements is sufficient for the assessment of the structural integrity of the irradiation capsule and for the geometry description within the thermal-hydraulic modeling. The space resolution and the overall

  16. Assessment of the structural integrity of a prototypical instrumented IFMIF high flux test module rig by fully 3D X-ray microtomography

    International Nuclear Information System (INIS)

    Tiseanu, Ion; Simon, Martin; Craciunescu, Teddy; Mandache, Bogdan N.; Heinzel, Volker; Stratmanns, Erwin; Simakov, Stanislaw P.; Leichtle, Dieter

    2007-01-01

    An inspection procedure to assess the mechanical integrity of the International Fusion Materials Irradiation Facility (IFMIF) capsules and rigs during the irradiation campaign is necessary. Due to its penetration ability and contrast mechanism, the X-ray microtomography is the only known tool that could meet these requirements. In the high flux test module (HFTM) of IFMIF miniaturized specimens are densely packed in capsules. The capsules, which wear electric heaters and thermocouples, are housed in rigs. To assure a well-defined thermal contact the heater wires have to be attached to the capsules by brazing them into grooves. The examination of the quality of the braze material layer is of crucial interest in order to assure the best heat coupling of the heater wires to the capsule. A high density of the heaters is necessary to maintain the required temperature and, in addition NaK filling of narrow channels is employed for improving the 3D-heat transfer between the irradiation specimens and the capsule wall. Fully 3D tomographic inspections of a prototypical HFTM instrumented capsule, developed and manufactured at FZK, were conducted. In order to identify the optimum irradiation parameters and scanning configuration we carried out a comparative NDT analysis on two microtomography facilities: a compact, high magnification installation at NILPRP and a high-end industrial tomography facility with higher X-ray energy and intensity at HWM. At optimum inspection parameters of a directional microfocus X-ray source (U = 220 kV and I = 300 μA) the geometry resolution was about 30 microns for characteristic dimension of the sample of 50 mm. Voids of 30 microns diameter and cracks of about 20 microns width can be detected. The absolute error of geometrical measurements is sufficient for the assessment of the structural integrity of the irradiation capsule and for the geometry description within the thermal-hydraulic modeling. The space resolution and the overall

  17. Digital imaging system in mammography with X-ray of two different energies

    International Nuclear Information System (INIS)

    Swientek, K.; Dabrowski, W.; Grybos, P.; Wiacek, P.; Cabal Rodrigez, A. E.; Sanchez, C.C.; Gambaccini, M.; Gaitan, J.L.; Prino, F.; Ramello, L.

    2005-01-01

    The progress in nuclear medicine stimulates the higher quality of image processing at diminished radiation dose. In the presented apparatus system Si-microstrip detector with two-thresholds multichannel amplitude analyzer have been applied. Data acquisition system evaluates simultaneously images for two X-ray beams of different energies following the Bragg reflection of the primary beam from the mosaic crystal. The contrast cancellation technique has been tested using the simple mammography phantom. An efficacy of this method suitable for medical imaging could be significantly increased using an intensive X-ray source and sensitive detectors

  18. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    Science.gov (United States)

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  19. Differential Deposition for Surface Figure Corrections in Grazing Incidence X-Ray Optics

    Science.gov (United States)

    Ramsey, Brian D.; Kilaru, Kiranmayee; Atkins, Carolyn; Gubarev, Mikhail V.; Broadway, David M.

    2015-01-01

    Differential deposition corrects the low- and mid- spatial-frequency deviations in the axial figure of Wolter-type grazing incidence X-ray optics. Figure deviations is one of the major contributors to the achievable angular resolution. Minimizing figure errors can significantly improve the imaging quality of X-ray optics. Material of varying thickness is selectively deposited, using DC magnetron sputtering, along the length of optic to minimize figure deviations. Custom vacuum chambers are built that can incorporate full-shell and segmented Xray optics. Metrology data of preliminary corrections on a single meridian of full-shell x-ray optics show an improvement of mid-spatial frequencies from 6.7 to 1.8 arc secs HPD. Efforts are in progress to correct a full-shell and segmented optics and to verify angular-resolution improvement with X-ray testing.

  20. Cosmic ray test of the Belle II z-vertex trigger

    Energy Technology Data Exchange (ETDEWEB)

    Neuhaus, Sara; Skambraks, Sebastian [Technische Universitaet Muenchen (Germany); Chen, Yang; Kiesling, Christian [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2016-07-01

    The z-vertex trigger is part of the first level track trigger in the Belle II experiment. Its task is the rejection of tracks not coming from the interaction region, suppressing a large part of the machine background. Therefore the z-vertex trigger allows to relax other track trigger conditions and thus strongly increases the efficiency for channels with low track multiplicity (e.g. tau pair production). The track trigger works in several steps, first combining hits to track segments, followed by a 2D track finding in the transverse plane and finally the 3D reconstruction. Our method employs neural networks to estimate the z-vertex without explicit track reconstruction. For the first real test with cosmic rays special neural networks have been prepared. Although the track shape in the cosmic test is different than in the Belle II experiment, the neural networks require only a retraining with an appropriate data set to adapt to the new geometry.