WorldWideScience

Sample records for rays post procedure

  1. Safety related to the implantation of jugular catheters for haemodialysis and usefulness of PA chest X rays post procedure

    International Nuclear Information System (INIS)

    Restrepo, Cesar A; Chacon, Jose Arnob; Mauricio Villota, Duvan

    2007-01-01

    The objective is to determine how safe the implantation of transient double lumen jugular catheters is for hemodialysis in patients with renal disease, and who require dialysis therapy and Posterior Anterior (PA) chest X-Ray post procedure. Design: observational descriptive study. Site: renal units at RTS Ltda. Sucursal Caldas (Hospital Santa Sofia y Hospital Infantil Rafael Henao Toro de la Cruz Roja). Patients: all patients with renal disease in whom it was necessary to do hemodyalitic therapy with implantation of a jugular catheter, with medical records of the events and complications that occurred during the procedure, with subsequent control AP chest X Ray and that showed reports made by the radiologist or physician who carried out the procedure, about the findings in the chest X Ray. Patients with renal disease, in whom jugular catheters had been inserted: Methods: variables such as age, gender, race, body mass index (BMI) etiology of the renal failure,time of evolution of the disease, indications for insertion, priority of catheter insertion, type of catheter inserted, amount of punctures, physician who carried out the procedure and patient's co-morbidities were analyzed. The events considered as complicated were analyzed as well as if there was any relationship with co-morbidities and the analyzed variables. Findings in the PA chest X-Ray were recorded and their relationship with the difficulties encountered during the procedure. A bi-variance analysis was done. The dependent and independent variables were classified in the nominal measurement scale. Results: 774 clinical histories were reviewed. 562 were excluded due to lack of variables and impossibility to read the notes. Men older than de 55 (45,7%). 212 (97.1%) patients with diagnosis of chronic renal disease (CRD) and in whom 238 procedures were carried out. seven patients (2,85%) had acute renal failure (ARF). The fi rst indication for central catheter insertion was in patients with chronic uremia

  2. 14 CFR 302.715 - Post-conference procedure.

    Science.gov (United States)

    2010-01-01

    ... desirable in the interest of further clarification and understanding of the issues. The granting of an... PROCEEDINGS) PROCEDURAL REGULATIONS RULES OF PRACTICE IN PROCEEDINGS Rules Applicable to Mail Rate Proceedings and Mail Contracts Informal Mail Rate Conference Procedure § 302.715 Post-conference procedure. No...

  3. Diagnostic x-ray procedures and risk of leukemia, lymphoma, and multiple myeloma

    International Nuclear Information System (INIS)

    Boice, J.D. Jr.; Morin, M.M.; Glass, A.G.; Friedman, G.D.; Stovall, M.; Hoover, R.N.; Fraumeni, J.F. Jr.

    1991-01-01

    Exposure to diagnostic x-rays and the risk of leukemia, non-Hodgkin's lymphoma (NHL), and multiple myeloma were studied within two prepaid health plans. Adult patients with leukemia (n = 565), NHL (n = 318), and multiple myeloma (n = 208) were matched to controls (n = 1390), and over 25,000 x-ray procedures were abstracted from medical records. Dose response was evaluated by assigning each x-ray procedure a score based on estimated bone marrow dose. X-ray exposure was not associated with chronic lymphocytic leukemia, one of the few malignant conditions never linked to radiation (relative risk [RR], 0.66). For all other forms of leukemia combined (n = 358), there was a slight elevation in risk (RR, 1.17) but no evidence of a dose-response relationship when x-ray procedures near the time of diagnosis were excluded. Similarly, patients with NHL were exposed to diagnostic x-ray procedures more often than controls (RR, 1.32), but the RR fell to 0.99 when the exposure to diagnostic x-ray procedures within 2 years of diagnosis was ignored. For multiple myeloma, overall risk was not significantly high (RR, 1.14), but there was consistent evidence of increasing risk with increasing numbers of diagnostic x-ray procedures. These data suggest that persons with leukemia and NHL undergo x-ray procedures frequently just prior to diagnosis for conditions related to the development or natural history of their disease. There was little evidence that diagnostic x-ray procedures were causally associated with leukemia or NHL. The risk for multiple myeloma, however, was increased among those patients who were frequently exposed to x-rays

  4. Additional radiation dose to population due to X-ray diagnostic procedures

    International Nuclear Information System (INIS)

    Chougule, A.

    2006-01-01

    Full text of publication follows: Discovery of X rays has revolutionised the medical diagnosis but the fact that the diagnostic radiological procedures contribute about 80 to 90 % of the radiation dose to population as compared to other man made radiation sources cannot be ignored especially when X ray diagnostic facilities are being made available to larger section of the society. The estimated frequency of radiological procedures in India is 12,000 procedures/ year/100,000 population, though it is quite less as compared to developed countries, its increasing day by day. As part of the project, a radiation protection survey of X ray installations and patient radiation dose measurement during various radiological procedures was undertaken. 193 X ray installations were surveyed and the radiation doses received by the patient during various radiological procedure was measured. For measurement of radiation doses, CaSO 4 : Dy thermoluminescence (T.L.) discs of size 13.3 mm diameter and 0.8 mm thickness were used. Pre annealed T.L. discs were fixed by adhesive tape on the patient skin at the center of entrance beam before the exposure. After exposure the T.L. discs were estimated f or entrance skin dose during that particular projection/ examination. 10,000 measurements at different centers during various radiological procedures were done. It was found that chest radiography accounts for 37 % of all radiological procedures and further it was observed that 70 % of the chest X rays were normal with out any pathology indicating scope for curtailing the unwarranted radiological procedures. The special investigations like barium swallow, barium meal and fallow through accounts for about 1.5 % of the total radiological procedures. The entrance skin dose [E.S.D.] during chest radiography was 0.3 + 0.1 mGy where as during K.U.B. and cervical spine radiography it was 6.2 + 1.1 mGy and 5.1 + 0.9 mGy respectively. The details of frequency of various radiological procedures and the

  5. Quantification procedures in micro X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit

    2003-01-01

    For the quantification in micro X-ray fluorescence analysis standardfree quantification procedures have become especially important. An introduction to the basic concepts of these quantification procedures is given, followed by a short survey of the procedures which are available now and what kind of experimental situations and analytical problems are addressed. The last point is extended by the description of an own development for the fundamental parameter method, which renders the inclusion of nonparallel beam geometries possible. Finally, open problems for the quantification procedures are discussed

  6. Endovascular thrombectomy and post-procedural headache.

    Science.gov (United States)

    Khan, Sabrina; Amin, Faisal Mohammad; Holtmannspötter, Markus; Hansen, Klaus; Florescu, Anna Maria; Fakhril-Din, Zainab; Petersen, Julie Falkenberg; Ghanizada, Hashmat; Ayata, Cenk; Gaist, David; Ashina, Messoud

    2017-12-01

    We investigated the prevalence of post-procedural headache in patients who have undergone thrombectomy for ischemic stroke, and correlated history of migraine with risk of peri-procedural complications. A total of 314 patients underwent thrombectomy at the Danish National Hospital from January 2012 to December 2014. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire according to the International Classification of Headache Disorders 3, beta version criteria. Among 96 eligible subjects, there was a significant decrease in migraine (p = 0.022) within the first 3 months after EVT compared to 1 year before treatment, which was further evident at interview time (on average 1.6 years after EVT, p = 0.013). A minority of patients experienced headaches for the first time within 3 months of their EVT (migraine 2, TTH 9), which persisted at interview time for subjects with migraine. Out of 12 subjects with peri-procedural complications, 2 had a history of migraine with aura. Thrombectomy leads to a significant decrease in previously known migraine, and new onset of headache in a small subset of patients. A history of migraine does not appear to predispose to peri-procedural complications.

  7. Quality control procedure for a general diagnostic x-ray machine

    International Nuclear Information System (INIS)

    Md Saion Salikin; Mazlyfarina Mohamad

    2001-01-01

    Performance tests of a particular medical diagnostic x-ray machine have to be carried out regularly in order to ensure that the machine always complies with the required standard. A performance report which is prepared based on the performance tests on the x-ray machine is used as one of the requirement by the authority for issuance and renewal licence to operate and use of the x-ray machine in a clinic or hospital. The Ministry of Health will only issue a licence to the clinic or hospital to use and operate x-ray machines, if the machines have complied with the standards. The clinic or hospital may get the service to carry out performance tests on a diagnostic x-ray machine from any licence H holder, issued by the authority under Atomic Energy Licensing Act 1984. A comparative study between the standard procedure and other procedures on performance test of a general diagnostic x-ray machine is carried out and presented in brief in this paper. The criteria for compliance or otherwise as required by the Ministry of Health Malaysia is discussed and explained in brief. (Author)

  8. Endovascular thrombectomy and post-procedural headache

    DEFF Research Database (Denmark)

    Khan, Sabrina; Amin, Faisal Mohammad; Holtmannspötter, Markus

    2017-01-01

    BACKGROUND: We investigated the prevalence of post-procedural headache in patients who have undergone thrombectomy for ischemic stroke, and correlated history of migraine with risk of peri-procedural complications. A total of 314 patients underwent thrombectomy at the Danish National Hospital from...... January 2012 to December 2014. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire according to the International Classification of Headache Disorders 3, beta version criteria. FINDINGS: Among 96 eligible subjects, there was a significant decrease in migraine...... (p = 0.022) within the first 3 months after EVT compared to 1 year before treatment, which was further evident at interview time (on average 1.6 years after EVT, p = 0.013). A minority of patients experienced headaches for the first time within 3 months of their EVT (migraine 2, TTH 9), which...

  9. Procedures for cryogenic X-ray ptychographic imaging of biological samples.

    Science.gov (United States)

    Yusuf, M; Zhang, F; Chen, B; Bhartiya, A; Cunnea, K; Wagner, U; Cacho-Nerin, F; Schwenke, J; Robinson, I K

    2017-03-01

    Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This manuscript describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.

  10. Procedures for cryogenic X-ray ptychographic imaging of biological samples

    Directory of Open Access Journals (Sweden)

    M. Yusuf

    2017-03-01

    Full Text Available Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This manuscript describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.

  11. An automated background estimation procedure for gamma ray spectra

    International Nuclear Information System (INIS)

    Tervo, R.J.; Kennett, T.J.; Prestwich, W.V.

    1983-01-01

    An objective and simple method has been developed to estimate the background continuum in Ge gamma ray spectra. Requiring no special procedures, the method is readily automated. Based upon the inherent statistical properties of the experimental data itself, nodes, which reflect background samples are located and used to produce an estimate of the continuum. A simple procedure to interpolate between nodes is reported and a range of rather typical experimental data is presented. All information necessary to implemented this technique is given including the relevant properties of various factors involved in its development. (orig.)

  12. Programs and procedures for assessing quality of spectral gamma-ray borehole data for the UGTA

    International Nuclear Information System (INIS)

    Conaway, J.G.

    1998-01-01

    This report describes the procedures and computer programs used to process spectral gamma-ray borehole logging data in the UGTA (UnderGround Test Area) program at the NTS (Nevada Test Site) to assess data quality. These programs and procedures were used to analyze data from five boreholes in the UGTA program. Development of these computer programs and procedures required considerable effort and the primary purpose of this report is to provide continuity with future activities related to spectral gamma-ray borehole logging in the UGTA program. This is especially important because of the long time interval between cessation of logging in April, 1996 and the next round of activity, which has not yet occurred. This report should also be useful if any quality control issues arise regarding past or forthcoming spectral gamma-ray log analyses. In the characterization work underway at the Nevada Test Site Underground Test Area, the logging contractor, Western Atlas, agreed to identify five artificial nuclides based on their gamma-ray signatures. Those nuclides are 60 Co, 106 Ru, 125 Sb, 134 Cs, and 137 Cs. In the case of 106 Ru, which is not a gamma emitter, any detected gamma rays come from the daughter nuclide 106 Rh which has a half-life of 30 s. With such a short half-life, 106 Rh can be considered to be in equilibrium with 106 Ru under most conditions so the result is the same as if the gamma rays were emitted by the 106 Ru. The Western Atlas spectral gamma-ray curve plots from a given borehole present detailed qualitative information on the apparent distribution of natural and artificial nuclides with depth in the borehole. The computer programs and procedures described in this report were used to provide a quality analysis of the contractor's processed data and to work with the contractor to validate and/or refine their existing automatic processing. This was done using a procedure that was developed and tested successfully in earlier work at the NTS; the revised

  13. Endoscopy versus radiology in post-procedural monitoring after peroral endoscopic myotomy (POEM).

    Science.gov (United States)

    Nast, Jan Friso; Berliner, Christoph; Rösch, Thomas; von Renteln, Daniel; Noder, Tania; Schachschal, Guido; Groth, Stefan; Ittrich, Harald; Kersten, Jan F; Adam, Gerhard; Werner, Yuki B

    2018-03-15

    The newly developed technique of peroral endoscopic myotomy (POEM) has been shown to be effective in several short- and mid-term studies. Limited information is available about the adequacy of immediate post-POEM monitoring tests. POEM was performed under general anesthesia in 228 patients (59.6% male, mean age 45.6 ± 15.5 years). Post-procedural checks comprised clinical and laboratory examination, and, during post-procedure days 1-5, endoscopy and-in the first 114 cases-radiologic examination using water-soluble contrast (1st group); the remaining patients underwent post-procedure controls without radiology (2nd group). Main outcome was value of endoscopic compared to radiologic control for recognition of early adverse events. In the first group, routine fluoroscopic contrast swallow suggested minor leakages at the mucosal entry site in two cases which was confirmed endoscopically in only one. Endoscopy revealed two minor entry site leakages and, in six additional cases, dislocated clips without leakage (overall 5.3%). All eight patients underwent reclipping and healed without clinical sequelae. In the 2nd group, endoscopy showed 5 clip dislocations (all reclipped) and one ischemic cardiac perforation in a patient with clinical deterioration on post-POEM day 1 who had to undergo surgery after confirmation of leakage by CT. Radiologic monitoring (contrast swallow) after POEM is not useful and can be omitted. Even routine endoscopic monitoring for detection and closure of minor defects of the mucosal entry site yields limited information with regards to final outcome; major complications are very rare and probably associated with clinical deterioration. Clinical Trials Gov Registration number of the main study: NCT01405417.

  14. Bureau of radiological health compliance testing procedures for cabinet S-ray systems

    International Nuclear Information System (INIS)

    Miller, E.A.; Sprau, D.

    1976-01-01

    A manual has been developed by the Bureau of Radiological Health of the Food and Drug Administration to establish procedures for the routine field testing of cabinet x-ray systems to determine compliance with the Federal Performance Standard for Cabinet X-Ray Systems, 21 CFR 1020.40. The manual provides specific instructions for testing each model of cabinet x-ray system. Results from the inspection are recorded on a data from which is designed to permit automatic data processing

  15. Assessment of organ doses by standard X-ray procedures in the GDR

    International Nuclear Information System (INIS)

    Tautz, M.; Brandt, G.A.

    1986-01-01

    A modern method has been described to assess the radiation burden by X-ray procedures with consideration of the standards of our Society for Medical Radiology in the GDR. The underlying methodology is a Monte Carlo computer technique, which simulates stochastically the energy deposition of X-ray photons in a mathematically described heterogeneous anthropomorphic phantom by Rosenstein (US Department of Health, Education and Welfare). To apply the procedure specific values for the following parameters must be determined for each dose estimation: projection and view, X-ray field size and location entrance exposure at skin surface, beam quality, source-to-image receptor distance. The base data are obtained in terms of tissue-air ratio. Organ doses were calculated for chest, urography, skull, cervical spine, thoracic spine, lumbar spine, pelvis and lymphography. Concluding possibilities have been discussed for reduction of radiation burden. 9 refs., 6 figs., 9 tabs. (author)

  16. Collective effective dose in Europe from x-ray and nuclear medicine procedures

    International Nuclear Information System (INIS)

    Bly, R.; Jaervinen, H.; Jahnen, A.; Olerud, H.; Vassileva, J.; Vogiatzi, S.

    2015-01-01

    Population doses from radiodiagnostic (X-ray and nuclear medicine) procedures in Europe were estimated based on data collected from 36 European countries. For X-ray procedures in EU and EFTA countries (except Liechtenstein) the collective effective dose is 547 500 man Sv, resulting in a mean effective dose of 1.06 mSv per caput. For all European countries included in the survey the collective effective dose is 605 000 man Sv, resulting in a mean effective dose of 1.05 mSv per caput. For nuclear medicine procedures in EU countries and EFTA (except Liechtenstein) countries the collective effective dose is 30 700 man Sv, resulting in a mean effective dose of 0.06 mSv per caput. For all European countries included in the survey the collective effective dose is 31 100 man Sv, resulting in a mean effective dose of 0.05 mSv per caput. (authors)

  17. Automatic segmentation of rotational x-ray images for anatomic intra-procedural surface generation in atrial fibrillation ablation procedures.

    Science.gov (United States)

    Manzke, Robert; Meyer, Carsten; Ecabert, Olivier; Peters, Jochen; Noordhoek, Niels J; Thiagalingam, Aravinda; Reddy, Vivek Y; Chan, Raymond C; Weese, Jürgen

    2010-02-01

    Since the introduction of 3-D rotational X-ray imaging, protocols for 3-D rotational coronary artery imaging have become widely available in routine clinical practice. Intra-procedural cardiac imaging in a computed tomography (CT)-like fashion has been particularly compelling due to the reduction of clinical overhead and ability to characterize anatomy at the time of intervention. We previously introduced a clinically feasible approach for imaging the left atrium and pulmonary veins (LAPVs) with short contrast bolus injections and scan times of approximately 4 -10 s. The resulting data have sufficient image quality for intra-procedural use during electro-anatomic mapping (EAM) and interventional guidance in atrial fibrillation (AF) ablation procedures. In this paper, we present a novel technique to intra-procedural surface generation which integrates fully-automated segmentation of the LAPVs for guidance in AF ablation interventions. Contrast-enhanced rotational X-ray angiography (3-D RA) acquisitions in combination with filtered-back-projection-based reconstruction allows for volumetric interrogation of LAPV anatomy in near-real-time. An automatic model-based segmentation algorithm allows for fast and accurate LAPV mesh generation despite the challenges posed by image quality; relative to pre-procedural cardiac CT/MR, 3-D RA images suffer from more artifacts and reduced signal-to-noise. We validate our integrated method by comparing 1) automatic and manual segmentations of intra-procedural 3-D RA data, 2) automatic segmentations of intra-procedural 3-D RA and pre-procedural CT/MR data, and 3) intra-procedural EAM point cloud data with automatic segmentations of 3-D RA and CT/MR data. Our validation results for automatically segmented intra-procedural 3-D RA data show average segmentation errors of 1) approximately 1.3 mm compared with manual 3-D RA segmentations 2) approximately 2.3 mm compared with automatic segmentation of pre-procedural CT/MR data and 3

  18. Near-optimum procedure for half-life measurement by high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Parker, J.L.

    1989-01-01

    A near-optimum procedure for using high-resolution γ-ray spectrometry to measure the half-lives of appropriate γ-ray- emitting-nuclides is presented. Among the important points of the procedure are the employment of the reference source method for implicit correction of pileup and deadtime losses; the use of full-energy peak-area ratios as the fundamental measured quantities; and continuous, high-rate data acquisition to obtain good results in a fraction of a half-life if desired. Equations are given for estimating the precision of the computed half-lives in terms of total measurement time, number of spectral acquisitions, and the precision of peak-area ratios. Results of 169 Yb half-life measurements are given as an example of the procedure's application. 3 refs., 2 tabs

  19. Prediction of post-operative pain after a laparoscopic tubal ligation procedure

    DEFF Research Database (Denmark)

    Rudin, A.; Wolner-Hanssen, P.; Hellbom, M.

    2008-01-01

    ligation procedure. METHODS: Assessments of anxiety, mood, psychological vulnerability and pre-operative pain were made before surgery using the State-Trait Anxiety Inventory (STAI), the Hospital Anxiety Depression Scale (HADS), a psychological vulnerability test and the Short-Form McGill Pain......BACKGROUND: Pre-operative identification of reliable predictors of post-operative pain may lead to improved pain management strategies. We investigated the correlation between pre-operative pain, psychometric variables, response to heat stimuli and post-operative pain following a laparoscopic tubal...... Questionnaire (SF-MPQ), respectively. Pre-operative assessments of thermal thresholds and pain response to randomized series of heat stimuli (1 s, 44-48 degrees C) were made with quantitative sensory testing technique. Post-operative pain intensity was evaluated daily by a visual analogue scale during rest...

  20. Genetic risk from diagnostic X-ray procedures

    International Nuclear Information System (INIS)

    Stephan, G.

    1980-01-01

    This essay introduces epidemiologic studies concerned with the question whether diagnostic X-ray procedures might be the cause of an increased genetic risk. All studies have selected Down's syndrome (mongolism) as genetic indicator. They indiscriminately present the opinion of the respective author. Approximately one half of the studies conclude that radiation exposure will not influence the spontaneous incidence of Down's syndrome in diagnostics, the other half finds a positive relationship between frequent radiation exposure and the incidence of the syndrome. For various reasons, explained in detail, the results of the studies under discussion are suitable for forming hypotheses, but should not be viewed as providing evidence. (orig.) [de

  1. [Implementation of a post-discharge surgical site infection system in herniorrhaphy and mastectomy procedures].

    Science.gov (United States)

    San Juan Sanz, Isabel; Díaz-Agero-Pérez, Cristina; Robustillo-Rodela, Ana; Pita López, María José; Oliva Iñiguez, Lourdes; Monge-Jodrá, Vicente

    2014-10-01

    Monitoring surgical site infection (SSI) performed during hospitalization can underestimate its rates due to the shortening in hospital stay. The aim of this study was to determine the actual rates of SSI using a post-discharge monitoring system. All patients who underwent herniorraphy or mastectomy in the Hospital Universitario Ramón y Cajal from 1 January 2011 to 31 December 2011 were included. SSI data were collected prospectively according to the continuous quality improvement indicators (Indicadores Clinicos de Mejora Continua de la Calidad [INCLIMECC]) monitoring system. Post-discharge follow-up was conducted by telephone survey. A total of 409patients were included in the study, of whom 299 underwent a herniorraphy procedure, and 110 underwent a mastectomy procedure. For herniorrhaphy, the SSI rate increased from 6.02% to 7.6% (the post-discharge survey detected 21.7% of SSI). For mastectomy, the SSI rate increased from 1.8% to 3.6% (the post-discharge survey detected 50% of SSI). Post-discharge monitoring showed an increased detection of SSI incidence. Post-discharge monitoring is useful to analyze the real trend of SSI, and evaluate improvement actions. Post-discharge follow-up methods need to standardised. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  2. Predictors of Post-Operative Pain Relief in Patients with Chronic Pancreatitis Undergoing the Frey or Whipple Procedure.

    Science.gov (United States)

    Sinha, Amitasha; Patel, Yuval A; Cruise, Michael; Matsukuma, Karen; Zaheer, Atif; Afghani, Elham; Yadav, Dhiraj; Makary, Martin A; Hirose, Kenzo; Andersen, Dana K; Singh, Vikesh K

    2016-04-01

    Post-operative pain relief in chronic pancreatitis (CP) is variable. Our objective was to determine clinical imaging or histopathologic predictor(s) of post-operative pain relief in CP patients undergoing the Whipple or Frey procedure. All patients who underwent a Whipple (n = 30) or Frey procedure (n = 30) for painful CP between January 2003 and September 2013 were evaluated. A toxic etiology was defined as a history of alcohol use and/or smoking. The pre-operative abdominal CT was evaluated for calcification(s) and main pancreatic duct (MPD) dilation (≥5 mm). The post-operative histopathology was evaluated for severe fibrosis. Clinical imaging and histopathologic features were evaluated as predictors of post-operative pain relief using univariable and multivariable regression analysis. A total of 60 patients (age 51.6 years, 53% males) were included in our study, of whom 42 (70%) reported post-operative pain relief over a mean follow-up of 1.1 years. There were 37 (62%) patients with toxic etiology, 36 (60%) each with calcification(s) and MPD dilation. A toxic etiology, calcifications, and severe fibrosis were associated with post-operative pain relief on univariable analysis (all p Whipple or Frey procedure.

  3. Fast procedures for coincidence-summing correction in γ-ray spectrometry

    International Nuclear Information System (INIS)

    De Felice, Pierino; Angelini, Paola; Fazio, Aldo; Biagini, Roberto

    2000-01-01

    Simplified and fast procedures for coincidence-summing correction in γ-ray spectrometry were investigated. These procedures are based on the usual theoretical expressions of the correction factors, but differ in the determination of the total efficiency curve based on the following approximations: (a) replacement, below the knee efficiency value, of the total efficiency by the full-energy peak efficiency; and (b) use of linear interpolations (in log-log plot) between only two experimental points above the knee efficiency value; or (c) assumption of a peak-to-total efficiency ratio independent on the counting geometry; or (d) assumption of a constant relation between the peak-to-total efficiency ratios and the photoelectric-to-total cross section ratios. The above approximations were separately assumed for determination of the coincidence-summing correction factors for nuclides with complex decay scheme ( 133 Ba, 134 Cs, 152 Eu) and for 60 Co and 88 Y measured on a 15% relative efficiency p-type coaxial HPGe detector, for three source-detector geometries: point source placed on top of and at 10 cm from the detector window, and 1 l Marinelli beaker filled with aqueous solution. The results were compared with those based on more accurate experimental determinations of the total efficiency curve from measurements of standard sources of eight different single-γ-ray emitters. The usefulness of each simplified procedure is evaluated with respect to its accuracy and to the reduction of the number of standard sources and measurement time

  4. Study of Post-Harvest Ambon Banana ( Musa acuminata ) Preservation Using X-Ray

    International Nuclear Information System (INIS)

    Dwijananti, P.; Handayani, L.; Marwoto, P.; Iswari, R.S.

    2016-01-01

    An exposure to Ambon banana ( Musa Acuminata ) samples has been done by using X-rays with current, voltage and exposure time are control parameters. This study aimed to determine storage ability of the post-harvest sample. Five samples were exposured by x-rays with the dose of (3-5) × 10 -14 Gy. The samples were stored at room temperature. Their mass and physical condition (color and smell) were evaluated every 3 days. It was found that the control sample which was not exposured by X-ray was ripe in the sixth day indicated by the yellow color and good smell of the banana. Meanwhile, the samples which were exposured by (3 - 5) × 10 -14 Gy doze of X-ray looked fresher and still had green color. These samples showed their ripening in the ninth day and their mass decrease was (12-13)% which is lower than the control sample. The preservation of banana can be done through low-dose X-ray exposure. (paper)

  5. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  6. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  7. Dose distribution in head and neck during dental x-ray procedures

    International Nuclear Information System (INIS)

    Mason, E.W.; Goepp, R.A.

    1978-01-01

    Previous studies, notably by Franklin (Angle Ortho., 43:53-64, 1973), have shown significant exposures during cephalometric dental procedures and ways in which these exposures can be reduced. Skin dose over thyroid tissue has been measured by Alcox (J. Am. Dent. Assoc., 88:568-579, 1974), and others. This study is an expansion of thyroid dose measurements by Block, Goepp, and Mason (Angle Ortho., 47:17-24, 1977). The internal dose distribution in the head and neck area due to cephalometric and panoramic dental x-ray procedures is shown along with the dependence of orbit and thyroid dose on patient positioning. Higher doses can be delivered to deep tissue by panoramic machines since tissue at the axis of rotation is exposed during the entire procedure. (author)

  8. X-ray exposure hazards for physicians performing ablation procedures and device implantation

    DEFF Research Database (Denmark)

    Marinskis, Germanas; Bongiorni, Maria Grazia; Dagres, Nikolaos

    2013-01-01

    The purpose of the survey was to evaluate physician's and authorities policies and clinical practices when using occupational X-ray during ablation procedures and device implantation. This survey shows infrequent use of lead gloves, radiation absorbing pads, and lead glass cabins, but increasing ...

  9. Post-surgical infections and perioperative antibiotics usage in pediatric genitourinary procedures.

    Science.gov (United States)

    Ellett, Justin; Prasad, Michaella M; Purves, J Todd; Stec, Andrew A

    2015-12-01

    Post-surgical infections (PSIs) are a source of preventable perioperative morbidity. No guidelines exist for the use of perioperative antibiotics in pediatric urologic procedures. This study reports the rate of PSIs in non-endoscopic pediatric genitourinary procedures at our institution. Secondary aims evaluate the association of PSI with other perioperative variables, including wound class (WC) and perioperative antibiotic administration. Data from consecutive non-endoscopic pediatric urologic procedures performed between August 2011 and April 2014 were examined retrospectively. The primary outcome was the rate of PSIs. PSIs were classified as superficial skin (SS) and deep/organ site (D/OS) according to Centers for Disease Control and Prevention guidelines, and urinary tract infection (UTI). PSIs were further stratified by WC1 and WC2 and perioperative antibiotic usage. A relative risk and chi-square analysis compared PSI rates between WC1 and WC2 procedures. A total of 1185 unique patients with 1384 surgical sites were reviewed; 1192 surgical sites had follow-up for inclusion into the study. Ten total PSIs were identified, for an overall infection rate of 0.83%. Of these, six were SS, one was D/OS, and three were UTIs. The PSI rate for WC1 (885 sites) and WC2 (307 sites) procedures was 0.34% and 2.28%, respectively, p antibiotics (0.35% vs. 0.33%). All WC2 procedures received antibiotics. Post-surgical infections are associated with significant perioperative morbidity. In some studies, PSI can double hospital costs, and contribute to hospital length of stay, admission to intensive care units, and impact patient mortality. Our study demonstrates that the rate of PSI in WC1 operations is low, irrespective of whether the patient received perioperative antibiotics (0.35%) or no antibiotics (0.33%). WC2 operations were the larger source of morbidity with an infection rate of 2.28% and a 6.7 fold higher increase in relative risk. WC1 procedures have a rate of

  10. Influence of UV Photo-Transfer on Post Irradiated Double Sulphate Poly-Crystals By Gamma And X-rays

    International Nuclear Information System (INIS)

    El-kolaly, M.A.

    2000-01-01

    Solid state thermoluminescence (TL) dosimetry has for many years been the pre-eminent method for quantifying ionizing radiation dose. In this work, thermoluminescence characteristics of the double sulphate (Li Cs So 4 ) poly-crystals have been studied after exposure to different doses from X and gamma radiation. The glue curves showed TL response of three peaks at 75,125,250 degree. The structure of the glue peaks due to X-rays is quite different from that due to gamma rays. UV exposure yields a regeneration of the TL peaks for the post irradiated samples for X or gamma radiation with some changes in the peaks structure especially the third peak. For the post X-ray irradiated crystals, the area under the third glow peak (III) increased linearly with the integrated time of UV exposures till about 30 min. after which no changes were observed; while , for the post gamma-irradiated crystals two linear regions were observed

  11. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  12. Pulsed Dose Radiofrequency Before Ablation of Medial Branch of the Lumbar Dorsal Ramus for Zygapophyseal Joint Pain Reduces Post-procedural Pain.

    Science.gov (United States)

    Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph

    2016-01-01

    One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. University hospital. Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on post-procedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. These interventions were carried out by one board accredited pain physician at one

  13. Laboratory manual on sample preparation procedures for x-ray micro-analysis

    International Nuclear Information System (INIS)

    1997-01-01

    X-ray micro fluorescence is a non-destructive and sensitive method for studying the microscopic distribution of different elements in almost all kinds of samples. Since the beginning of this century, x-rays and electrons have been used for the analysis of many different kinds of material. Techniques which rely on electrons are mainly developed for microscopic studies, and are used in conventional Electron Microscopy (EM) or Scanning Electron Microscopy (SEM), while x-rays are widely used for chemical analysis at the microscopic level. The first chemical analysis by fluorescence spectroscopy using small x-ray beams was conducted in 1928 by Glockner and Schreiber. Since then much work has been devoted to developing different types of optical systems for focusing an x-ray beam, but the efficiency of these systems is still inferior to the conventional electron optical systems. However, even with a poor optical efficiency, the x-ray microbeam has many advantages compared with electron or proton induced x-ray emission methods. These include: The analyses are non-destructive, losses of mass are negligible, and due to the low thermal loading of x-rays, materials which may be thermally degraded can be analysed; Samples can be analysed in air, and no vacuum is required, therefore specimens with volatile components such as water in biological samples, can be imaged at normal pressure and temperature; No charging occurs during analysis and therefore coating of the sample with a conductive layer is not necessary; With these advantages, simpler sample preparation procedures including mounting and preservation can be used

  14. Trends and the determination of effective doses for standard X-ray procedures

    International Nuclear Information System (INIS)

    Johnson, H.M.; Neduzak, C.; Gallet, J.; Sandeman, J.

    2001-01-01

    Trends in the entrance skin exposures (air kerma) for standard x-ray imaging procedures are reported for the Province of Manitoba, Canada. Average annual data per procedure using standard phantoms and standard ion chambers have been recorded since 1981. For example, chest air kerma (backscatter included) has decreased from 0.14 to 0.09 mGy. Confounding factors may negate the gains unless facility quality control programs are maintained. The data were obtained for a quality assurance and regulatory compliance program. Quoting such data for risk evaluation purposes lacks rigor hence a compartment model for organ apportioning, using organ absorbed doses and weighting factors, has been applied to determine effective dose per procedure. The effective doses for the standard procedures are presented, including the value of 0.027 mSv (1999) calculated for the effective dose in PA chest imaging. (author)

  15. Restablished Accretion in Post-outburst Classical Novae Revealed by X-rays

    Science.gov (United States)

    Hernanz, Margarita; Ferri, Carlo; Sala, Glòria

    2009-05-01

    Classical novae are explosions on accreting white dwarfs (hereinafter WDs) in cataclysmic variables (hereinafter CVs) a hydrogen thermonuclear runaway on top of the WD is responsible for the outburst. X-rays provide a unique way to study the turn-off of H-burning, because super soft X-rays reveal the hot WD photosphere, but also to understand how accretion is established again in the binary system. Observations with XMM-Newton of some post-outburst novae have revealed such a process, but a coverage up to larger energies -as Simbol-X will provide- is fundamental to well understand the characteristics of the binary system and of the nova ejecta. We present a brief summary of our results up to now and prospects for the Simbol-X mission.

  16. MODERN PECULIARITIES OF THE MEDICAL EXPOSURE LEVELS FORMING OF THE TATARSTAN REPUBLIC POPULATION DURING X-RAY PROCEDURES IMPLEMENTATION

    Directory of Open Access Journals (Sweden)

    S. A. Ryzhkin

    2015-01-01

    Full Text Available The purpose. The purpose of the investigation is an assessment of the peculiarities of forming and registration of the collective doses of patients and the population of the Tatarsatan Republic (RT from medical exposure and the development of measures for optimization of this radiation factor.Materials and methods. The analysis is based on the forms of the Federal statistical observation № 3-DOZ «Data on the exposure doses to patients obtained during medical radiological examination» (form № 3-DOZ and radiation-hygienic passports of RT for the period from 2006 to 2013.The results. Annually in RT there is an increase of the number of performed X-ray procedures, which reached the value of 6279696 (1.64 procedures per resident per year in 2013. During the reporting period (from 2006 to 2013 the structure of the performed X-ray procedures has also changed. It is observed that the percentage of fluorography procedures in the overall structure decreased from 41.3% to 31.3% at the same time the level of absolute value of annually performed fluorography procedures is stable. There is an increase in the absolute number of radiographic procedures performed during the period from 2578754 to 4072810 X-rays per year, that is 1.58 times higher. Absolute and relative values related to X-ray fluoroscopy examinations decreased from 1.1% to 0.7%. In contrast, the absolute number of annually performed X-ray computed tomography examinations (CT has increased over the period by 3.3 times and percentage of CT in overall structure of X-ray procedure is 2.7%. The number of special investigations has increased in 2.1 times, but the relative value remained at average level of 0.4% on general background of the increasing of X-ray activity in the region. This fact influenced the change in the radiation-hygienic indexes of medical radiation exposure of the population of RT. According to №3-DOZ forms and radiation-hygienic passports of the

  17. A recommended procedure for estimating the cosmic-ray spectral parameter of a simple power law

    CERN Document Server

    Howell, L W

    2002-01-01

    A simple power law model with single spectral index alpha sub 1 is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10 sup 1 sup 3 eV. Two procedures for estimating alpha sub 1 --the method of moments and maximum likelihood (ML)--are developed and their statistical performance are compared. The ML procedure is shown to be the superior approach and is then generalized for application to real cosmic-ray data sets. Several other important results, such as the relationship between collecting power and detector energy resolution and inclusion of a non-Gaussian detector response function, are presented. These results have many practical benefits in the design phase of a cosmic-ray detector as they permit instrument developers to make important trade studies in design parameters as a function of one of the science objectives.

  18. Staff and patient exposure to X-ray radiation during cardiac procedures

    International Nuclear Information System (INIS)

    Jankowski, J.; Papierz, D.; Domienik, J.; Kacprzyk, J.; Tybor-Czerwinska, M.; Werduch, A.

    2008-01-01

    The aim of this study was to define and compare staff and patient doses during the most common types of cardiac procedures. The influence of operators' technique and quality of X-ray unit in use on doses received by the staff and patients was investigated. The study was conduced in two independent hemodynamic rooms (I and II). The doses to hand for medical staff (operators and nurses) were monitored. For hand dose assessment, ring thermoluminescent dosimeters were used. Regarding patient dosimetry, dose-area product was collected for selected procedures. The monthly hand doses ranged from 0.4 mSv to 41.2 mSv in room I and from 0.1 to 8.95 mSv in room II. On the basis of the above measurements, the annual doses were estimated. The maximum annual hand doses for the operator and for the nurse in room I were 232.8 mSv/year and 11.5 mSv/year and in room II - 29.8 mSv/year and 14.1 mSv/year, respectively. Additionally, to compare the doses received by the particular medical operators, the doses were normalized to the total workload. Hand dose per procedure ranged from 109 to 614 μSv/procedure and were significantly larger in room I. The typical DAP values (median) recorded for the CA and CA+PTCA procedures were 55 Gy/cm 2 and 171 Gy/cm 2 in room I and 35 Gy/cm 2 and 87 Gy/cm 2 in the room II, respectively. As a result of this survey, the impact of medical operator's experience as well as technique and quality of available X-ray units on doses received by staff and patients has been proven. On the basis of the above results, the special need for monitoring hand doses for medical staff, apart from the effective dose, has been recognized. (author)

  19. Fresnel diffraction correction by phase-considered iteration procedure in soft X-ray projection microscopy

    International Nuclear Information System (INIS)

    Shiina, Tatsuo; Suzuki, Tsuyoshi; Honda, Toshio; Ito, Atsushi; Kinjo, Yasuhito; Yoshimura, Hideyuki; Yada, Keiji; Shinohara, Kunio

    2009-01-01

    In soft X-ray projection microscopy, it is easy to alter the magnification by changing the distance between the pinhole and the specimen, while the image is blurred because the soft X-rays are diffracted through the propagation from specimen to CCD detector. We corrected the blurred image by the iteration procedure of Fresnel to inverse Fresnel transformation taking phase distribution of the specimen into account. The experiments were conducted at the BL-11A of the Photon Factory, KEK, Japan for the specimens such as glass-capillaries, latex-particles, dried mammalian cells and human chromosomes. Many of those blurred images were corrected adequately by the iteration procedure, though some images such as those which have high-contrast or are overlapped by small cells still remain to be improved.

  20. Semi-empirical procedures for correcting detector size effect on clinical MV x-ray beam profiles

    International Nuclear Information System (INIS)

    Sahoo, Narayan; Kazi, Abdul M.; Hoffman, Mark

    2008-01-01

    The measured radiation beam profiles need to be corrected for the detector size effect to derive the real profiles. This paper describes two new semi-empirical procedures to determine the real profiles of high-energy x-ray beams by removing the detector size effect from the measured profiles. Measured profiles are corrected by shifting the position of each measurement point by a specific amount determined from available theoretical and experimental knowledge in the literature. The authors developed two procedures to determine the amount of shift. In the first procedure, which employs the published analytical deconvolution procedure of other investigators, the shift is determined from the comparison of the analytical fit of the measured profile and the corresponding analytical real profile derived from the deconvolution of the fitted measured profile and the Gaussian detector response function. In the second procedure, the amount of shift at any measurement point is considered to be proportional to the value of an analytical function related to the second derivative of the real profile at that point. The constant of proportionality and a parameter in the function are obtained from the values of the shifts at the 90%, 80%, 20%, and 10% dose levels, which are experimentally known from the published results of other investigators to be approximately equal to half of the radius of the detector. These procedures were tested by correcting the profiles of 6 and 18 MV x-ray beams measured by three different ionization chambers and a stereotactic field diode detector with 2.75, 2, 1, and 0.3 mm radii of their respective active cylindrical volumes. The corrected profiles measured by different detectors are found to be in close agreement. The detector size corrected penumbra widths also agree with the expected values based on the results of an earlier investigation. Thus, the authors concluded that the proposed procedures are accurate and can be used to derive the real

  1. Differentiating intraparenchymal hemorrhage from contrast extravasation on post-procedural noncontrast CT scan in acute ischemic stroke patients undergoing endovascular treatment

    Energy Technology Data Exchange (ETDEWEB)

    Payabvash, Seyedmehdi [Zeenat Qureshi Stroke Institute, Minneapolis, MN (United States); University of Minnesota, Department of Radiology, Minneapolis, MN (United States); Qureshi, Mushtaq H.; Khan, Shayaan M.; Khan, Mahnoor; Majidi, Shahram; Pawar, Swaroop; Qureshi, Adnan I. [Zeenat Qureshi Stroke Institute, Minneapolis, MN (United States)

    2014-09-15

    This study aimed to identify the imaging characteristics that can help differentiate intraparenchymal hemorrhage from benign contrast extravasation on post-procedural noncontrast CT scan in acute ischemic stroke patients after endovascular treatment. We reviewed the clinical and imaging records of all acute ischemic stroke patients who underwent endovascular treatment in two hospitals over a 3.5-year period. The immediate post-procedural CT scan was evaluated for the presence of hyperdense lesion(s). The average attenuation of the lesion(s) was measured. Intraparenchymal hemorrhage was defined as a persistent hyperdensity visualized on follow-up CT scan, 24 h or greater after the procedure. Of the 135 patients studied, 74 (55 %) patients had hyperdense lesion(s) on immediate post-procedural CT scan. Follow-up scans confirmed the diagnosis of intraparenchymal hemorrhage in 20 of these 74 patients. A receiver operating characteristic analysis showed that the average attenuation of the most hyperdense lesion can differentiate intraparenchymal hemorrhage from contrast extravasation with an area under the curve of 0.78 (p = 0.001). An average attenuation of <50 Hounsfield units (HU) in the most visually hyperattenuating hyperdense lesion had 100 % specificity and 56 % sensitivity for identification of contrast extravasations. Petechial hyperdensity was seen in 46/54 (85 %) patients with contrast extravasation versus 9/20 (45 %) patients with intraparenchymal hemorrhage on the immediate post-procedural CT scan (p < 0.001). An average attenuation <50 HU of the most hyperattenuating hyperdense parenchymal lesion on immediate post-procedural CT scan was very specific for differentiating contrast extravasation from intraparenchymal hemorrhage in acute ischemic stroke patients after endovascular treatment. (orig.)

  2. Differentiating intraparenchymal hemorrhage from contrast extravasation on post-procedural noncontrast CT scan in acute ischemic stroke patients undergoing endovascular treatment

    International Nuclear Information System (INIS)

    Payabvash, Seyedmehdi; Qureshi, Mushtaq H.; Khan, Shayaan M.; Khan, Mahnoor; Majidi, Shahram; Pawar, Swaroop; Qureshi, Adnan I.

    2014-01-01

    This study aimed to identify the imaging characteristics that can help differentiate intraparenchymal hemorrhage from benign contrast extravasation on post-procedural noncontrast CT scan in acute ischemic stroke patients after endovascular treatment. We reviewed the clinical and imaging records of all acute ischemic stroke patients who underwent endovascular treatment in two hospitals over a 3.5-year period. The immediate post-procedural CT scan was evaluated for the presence of hyperdense lesion(s). The average attenuation of the lesion(s) was measured. Intraparenchymal hemorrhage was defined as a persistent hyperdensity visualized on follow-up CT scan, 24 h or greater after the procedure. Of the 135 patients studied, 74 (55 %) patients had hyperdense lesion(s) on immediate post-procedural CT scan. Follow-up scans confirmed the diagnosis of intraparenchymal hemorrhage in 20 of these 74 patients. A receiver operating characteristic analysis showed that the average attenuation of the most hyperdense lesion can differentiate intraparenchymal hemorrhage from contrast extravasation with an area under the curve of 0.78 (p = 0.001). An average attenuation of <50 Hounsfield units (HU) in the most visually hyperattenuating hyperdense lesion had 100 % specificity and 56 % sensitivity for identification of contrast extravasations. Petechial hyperdensity was seen in 46/54 (85 %) patients with contrast extravasation versus 9/20 (45 %) patients with intraparenchymal hemorrhage on the immediate post-procedural CT scan (p < 0.001). An average attenuation <50 HU of the most hyperattenuating hyperdense parenchymal lesion on immediate post-procedural CT scan was very specific for differentiating contrast extravasation from intraparenchymal hemorrhage in acute ischemic stroke patients after endovascular treatment. (orig.)

  3. Quantitative analysis of crystalline pharmaceuticals in tablets by pattern-fitting procedure using X-ray diffraction pattern.

    Science.gov (United States)

    Takehira, Rieko; Momose, Yasunori; Yamamura, Shigeo

    2010-10-15

    A pattern-fitting procedure using an X-ray diffraction pattern was applied to the quantitative analysis of binary system of crystalline pharmaceuticals in tablets. Orthorhombic crystals of isoniazid (INH) and mannitol (MAN) were used for the analysis. Tablets were prepared under various compression pressures using a direct compression method with various compositions of INH and MAN. Assuming that X-ray diffraction pattern of INH-MAN system consists of diffraction intensities from respective crystals, observed diffraction intensities were fitted to analytic expression based on X-ray diffraction theory and separated into two intensities from INH and MAN crystals by a nonlinear least-squares procedure. After separation, the contents of INH were determined by using the optimized normalization constants for INH and MAN. The correction parameter including all the factors that are beyond experimental control was required for quantitative analysis without calibration curve. The pattern-fitting procedure made it possible to determine crystalline phases in the range of 10-90% (w/w) of the INH contents. Further, certain characteristics of the crystals in the tablets, such as the preferred orientation, size of crystallite, and lattice disorder were determined simultaneously. This method can be adopted to analyze compounds whose crystal structures are known. It is a potentially powerful tool for the quantitative phase analysis and characterization of crystals in tablets and powders using X-ray diffraction patterns. Copyright 2010 Elsevier B.V. All rights reserved.

  4. Emergency procedures

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Emergency Procedures: emergency equipment, emergency procedures; emergency procedure involving X-Ray equipment; emergency procedure involving radioactive sources

  5. High coronary calcium score and post-procedural CK-MB are noninvasive predictors of coronary stent restenosis

    Directory of Open Access Journals (Sweden)

    Lee JB

    2017-02-01

    Full Text Available Jae-Beom Lee,1 Yun-Seok Choi,2 Woo-Baek Chung,2 Ami Kwon,2 Chul-Soo Park,2 Man-Young Lee2 1Anyang Sam Hospital, 2Division of Cardiology, Department of Internal Medicine, Youido St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea Purpose: High coronary calcium score (CCS and post-procedural cardiac enzyme may be related with poor outcomes in patients with coronary stent implantation. Methods: A total of 1,072 patients (63.2% male, mean age: 61.7±10.3 years who underwent coronary multi-detect computed tomography at index procedure and follow-up coronary angiography (CAG after drug-eluting stent (DES were divided into two groups: those with and without target lesion revascularization (TLR; >50% reduction in luminal stent diameter or angina symptoms on follow-up CAG. The CCSs for predicting stent revascularization were elucidated. Results: There were no significant differences between the two groups with regard to risk factors. The initial CCS was significantly higher in the TLR group (1,102.4±743.7 vs 345.8±51.05, P=0.04. After adjustment of significant factors for TLR, only CCS and post-procedural creatine kinase MB form (CK-MB elevation were significant predictors of coronary artery TLR. Receiver operation curve revealed that >800 in CCS had 69% in sensitivity and 88% in specificity about predicting the TLR. Conclusion: High CCS with post-procedural CK-MB might be the useful predictors for TLR after DES implantation. Keywords: coronary restenosis, drug-eluting stents, calcium, creatine kinase

  6. Exposure to rays and radiation hazards in connection with diagnostic X-ray procedures in children

    International Nuclear Information System (INIS)

    Protzer, K.

    1988-01-01

    In this study, figures and data about radiation exposures for diagnostic purposes are surveyed that were collected in connection with X-ray procedures in children. The data were sorted according to body regions and techniques required for their examination so as to permit separate analyses of procedures in the urogenital tract (intravenous urogramme, micturition cystourethrography), thorax (angiocardiogramme, thoractic aortogramme, examinations using cardiac catheters), gastrointestinal system (fluoroscopy and contrast-enhanced irrigoscopy), pelvis (survey radiography), skull (computed tomography) as well as in miscellaneous group of further origins. The second part of the report discusses the uncertainties surrounding the assessment of radiation hazards and indicated radiation doses. A formula is represented for the calculation of life-time reductions that can be applied to any type of cancer and embraces a number of factors like life expectancy at age X, the patient's age at the time of radiotherapy, the five-year-survival rate for the condition under investigation and the diseased organ. At the end of the study, some methods are pointed out that may be helpful in limiting radiation exposure. (KST) [de

  7. Exposure measurement in the neighboring hospital beds during an x-ray procedure in hospitalization unit

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Rafael E.; Capeleti, Felipe F.; Cabete, Henrique V., E-mail: rafael.goto@fcmsantacasasp.edu.br, E-mail: felipe.capeleti@fcmsantacasasp.edu.br, E-mail: henrique@gmpbrasil.com.br [Faculdade de Ciencias Medicas da Santa Casa Sao Paulo, SP (Brazil); GMP Consultoria em Radioprotecao e Fisica Medica e Assessoria LTDA, Sao Paulo, SP (Brazil)

    2017-11-01

    There are lots of discussion about the exposure in hospitalization units in Brazil, especially around labor legislation and economic advantages of unhealthiness. With the attention focused on hospitalized patients, there were measured the exposure in neighboring beds of the patient submitted to an X-ray procedure with a mobile X-ray system that could be used to illustrate the discussion with consistent values. The most common X-ray procedure made in hospitalization units are chests images with techniques between 70 to 120 kV and 5 to 20 mAs. The measurement was made during routine exposure and simulations using a scattering phantom with Radcal AccuPro electrometer and 1800cc ionization chamber in a private hospital and a philanthropic hospital, both in Sao Paulo, Brazil. The ionization chambers are placed at 2 meters distance of the patient exposed of both sides during the routine procedure. During the simulation, a nylon phantom of 20 centimeters thick and 30 x 30 cm² size was placed on the bed, a typical exposure technique was used and the exposure was measured surrounding the phantom at 0.6, 1.0 and 2.0 meters distance for scattered radiation characterization. Initial results showed that the neighboring exposure at about 2 meters distance from the exposed patient bed have low values, even when exposure is integrated during the length of hospital stay. Therefore, the exposure in hospitalization units are very low compared to the exams doses. (author). (author)

  8. 29 CFR 37.64 - What procedures must the Director follow when CRC has completed a post-approval compliance review?

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true What procedures must the Director follow when CRC has completed a post-approval compliance review? 37.64 Section 37.64 Labor Office of the Secretary of Labor... (WIA) Compliance Procedures § 37.64 What procedures must the Director follow when CRC has completed a...

  9. Observations of a post-flare radio burst in X-rays

    Science.gov (United States)

    Svestka, Z.; Hoyng, P.; Van Tend, W.; Boelee, A.; De Jager, C.; Stewart, R. T.; Acton, L. W.; Bruner, E. C.; Gabriel, A. H.; Rapley, C. G.

    1982-01-01

    More than six hours after the two-ribbon flare of May 21, 1980, the hard X-ray spectrometer aboard the SMM imaged an extensive arch above the flare region which was found to be the lowest part of a stationary post-flare noise storm recorded at the same time at Culgoora. The bent crystal spectrometer aboard the SMM confirms that the arch emission was basically thermal. Variations in brightness and energy spectrum at one of the supposed footpoints of the arch are seen as correlation in time with radio brightness, suggesting that suprathermal particles from the radio noise regions dumped in variable quantities onto the low corona and transition layer.

  10. Electronprobe X-ray microanalysis of biological specimens improvement of a number of quantification procedures

    International Nuclear Information System (INIS)

    Boekestein, A.

    1984-01-01

    In this thesis an investigation is described to establish which quantification procedures can be used in the X-ray microanalysis of biological specimens. Two classes of specimens have been distinguished from each other, i.e. thick specimens (opaque to the beam electrons) and thin specimens (transparent to the beam electrons). (Auth.)

  11. Procedure of trace element analysis in oyster tissues by using X-ray fluorescence

    International Nuclear Information System (INIS)

    Vo Thi Tuong Hanh; Dinh Thi Bich Lieu; Dinh Thien Lam and Nguyen Manh Hung

    2004-01-01

    The procedure of trace element analysis such as Ca, Mn, Fe, Zn, Cu, Pb in molluscs (oyster tissues) was established by using X-ray fluorescence techniques. The procedure was investigated from the sample collection, drying, ashing ratio to the analytical techniques by using Cd-109, detector Si (Li) and the peak processing MCAPLUS program was applied for this study. The procedure is based on direct comparison with certified concentrations of international standard reference SRM 1566b Oyster Tissue of National Institute of Standards and Technology, Department of commerce, United States of America for Ca, Mn, Fe, Zn, Cu and the Standard Addition Methods for Pb. The accuracy of the Standard Addition Methods was estimated by CRM281 Rye Grass of Community Bureau of Reference-BCR, European Commission. The results of 10 samples which were collected from several markets in Hanoi are shown. (author)

  12. Recommended safety procedures for the selection, installation and use of baggage inspection x-ray equipment

    International Nuclear Information System (INIS)

    1978-05-01

    Good X-ray equipment alone will not preclude unnecessary exposure to x-radiation. The equipment must be installed, maintained and used by adequately trained personnel, with due regard for the inherent hazards of such equipment and an appreciation of the need to observe proper operational procedures. It is the intent of this Code to define equipment specifications and conditions of installation and use for baggage inspection X-ray equipment, such that the hazard to operating personnel and the general public from such devices remains negligibly small. (auth)

  13. The primary exposure standard of ENEA for medium energy X-ray: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a medium energy X-ray free-air chamber used, as primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the Enea in Italy. The main features of an X-ray facility for the production of radiation between 40 KeV and 400 KeV are also described. The measurements procedures are then analyzed with respect to the realization of the exposure unit in the relevant energy range. Finally the results of some international comparisons are reported

  14. Bioethics and power: Informed consent procedures in post-socialist Latvia.

    Science.gov (United States)

    Putniņa, Aivita

    2013-12-01

    This paper explores two lines of development in the donor consent procedures in post-Soviet Latvia. The paper is based on secondary analysis of interview, focus group discussion data, and media and legal text material collected throughout three previously conducted research projects on organ transplantation, population genome project and xenotransplantation focusing on the historical development of the issues of donor consent across these three fields of medical technologies. The paper argues that the quality of consent depends not as much on political and legal change per se as on the strengthening of the position of both medical specialists and donors, facilitating bonds between the two. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Impact of procedure on the post-operative infection risk of patients after elective colon surgery.

    Science.gov (United States)

    Blitzer, David N; Davis, John M; Ahmed, Nasim; Kuo, Yen-Hong; Kuo, Yen-Liang

    2014-12-01

    Post-operative infection impacts the quality of patient care, prolongs the length of hospital stay, and utilizes more health care resources. The purpose of this study was to compare the rates of surgical site infection among three major surgical procedures for treating patients with colon pathology. The location of colon resection impacts the post-operative infection rate. A retrospective cohort study was conducted by using the 2006 Nationwide Inpatient Sample. Adult patients (age ≥18 yr) with colon diseases are the population of interest. The disease status and procedures were categorized according to the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM). Patients with a primary diagnosis of diverticulosis of the colon without hemorrhage (ICD-9-CM codes: 562.11 and 562.12) or malignant neoplasm of the colon (ICD-9-CM codes: 153.x, where x represents the possible digits within this ICD-9-CM code category), with procedures of open and other right hemicolectomy (ORH; ICD-9-CM code: 45.73) or open and other left hemicolectomy (OLH; ICD-9-CM code: 45.75), or open and other sigmoidectomy (OS; ICD-9-CM code: 45.76) were included for this study. The primary measured outcome for the study was surgical site infection. There were an estimated 26,381 ORH procedures, 9,558 OLH procedures, and 31,656 OS procedures performed in 2006. There was a significant difference among procedures with respect to their age distributions (mean [standard error]: ORH vs. OLH vs. OS=70.5 [0.2] vs. 63.8 [0.3] vs. 59.5 [0.2] yr, pinfection rates: ORH vs. OLH vs. OS=2.9% vs. 5.6% vs. 4.9%, pinfection for OLH (AOR [95% CI]: 1.31 [1.04-1.64], p=0.02) compared with OS. Different sites of colon operations were associated with different risks of surgical site infections. Accordingly, appropriate pre-operative measures should address these differences.

  16. Post-Mission Quality Assurance Procedure for Survey-Grade Mobile Mapping Systems

    Science.gov (United States)

    Kerstinga, A. P.; Friess, P.

    2016-06-01

    Mobile Mapping Systems (MMS) consist of terrestrial-based moving platforms that integrate a set of imaging sensors (typically digital cameras and laser scanners) and a Position and Orientation System (POS), designed to collect data of the surrounding environment. MMS can be classified as "mapping-grade" or "survey-grade" depending on the system's attainable accuracy. Mapping-grade MMS produce geospatial data suitable for GIS applications (e.g., asset management) while survey-grade systems should satisfy high-accuracy applications such as engineering/design projects. The delivered accuracy of an MMS is dependent on several factors such as the accuracy of the system measurements and calibration parameters. It is critical, especially for survey-grade systems, to implement a robust Quality Assurance (QA) procedure to ensure the achievement of the expected accuracy. In this paper, a new post-mission QA procedure is presented. The presented method consists of a fully-automated self-calibration process that allows for the estimation of corrections to the system calibration parameters (e.g., boresight angles and lever-arm offsets relating the lidar sensor(s) to the IMU body frame) as well as corrections to the system measurements (e.g., post-processed trajectory position and orientation, scan angles and ranges). As for the system measurements, the major challenge for MMS is related to the trajectory determination in the presence of multipath signals and GNSS outages caused by buildings, underpasses and high vegetation. In the proposed self-calibration method, trajectory position errors are properly modelled while utilizing an efficient/meaningful trajectory segmentation technique. The validity of the proposed method is demonstrated using a dataset collected under unfavorable GNSS conditions.

  17. POST-MISSION QUALITY ASSURANCE PROCEDURE FOR SURVEY-GRADE MOBILE MAPPING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. P. Kerstinga

    2016-06-01

    Full Text Available Mobile Mapping Systems (MMS consist of terrestrial-based moving platforms that integrate a set of imaging sensors (typically digital cameras and laser scanners and a Position and Orientation System (POS, designed to collect data of the surrounding environment. MMS can be classified as “mapping-grade” or “survey-grade” depending on the system’s attainable accuracy. Mapping-grade MMS produce geospatial data suitable for GIS applications (e.g., asset management while survey-grade systems should satisfy high-accuracy applications such as engineering/design projects. The delivered accuracy of an MMS is dependent on several factors such as the accuracy of the system measurements and calibration parameters. It is critical, especially for survey-grade systems, to implement a robust Quality Assurance (QA procedure to ensure the achievement of the expected accuracy. In this paper, a new post-mission QA procedure is presented. The presented method consists of a fully-automated self-calibration process that allows for the estimation of corrections to the system calibration parameters (e.g., boresight angles and lever-arm offsets relating the lidar sensor(s to the IMU body frame as well as corrections to the system measurements (e.g., post-processed trajectory position and orientation, scan angles and ranges. As for the system measurements, the major challenge for MMS is related to the trajectory determination in the presence of multipath signals and GNSS outages caused by buildings, underpasses and high vegetation. In the proposed self-calibration method, trajectory position errors are properly modelled while utilizing an efficient/meaningful trajectory segmentation technique. The validity of the proposed method is demonstrated using a dataset collected under unfavorable GNSS conditions.

  18. Neutron, gamma ray and post-irradiation thermal annealing effects on power semiconductor switches

    Science.gov (United States)

    Schwarze, G. E.; Frasca, A. J.

    1991-01-01

    The effects of neutron and gamma rays on the electrical and switching characteristics of power semiconductor switches must be known and understood by the designer of the power conditioning, control, and transmission subsystem of space nuclear power systems. The SP-100 radiation requirements at 25 m from the nuclear source are a neutron fluence of 10(exp 13) n/sq cm and a gamma dose of 0.5 Mrads. Experimental data showing the effects of neutrons and gamma rays on the performance characteristics of power-type NPN Bipolar Junction Transistors (BJTs), Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs), and Static Induction Transistors (SITs) are presented. These three types of devices were tested at radiation levels which met or exceeded the SP-100 requirements. For the SP-100 radiation requirements, the BJTs were found to be most sensitive to neutrons, the MOSFETs were most sensitive to gamma rays, and the SITs were only slightly sensitive to neutrons. Post-irradiation thermal anneals at 300 K and up to 425 K were done on these devices and the effectiveness of these anneals are also discussed.

  19. Procedure for analyzing the x-ray line profiles of disordered carbons

    International Nuclear Information System (INIS)

    Henry, L.G.; Bragg, R.H.; Bose, S.

    1981-12-01

    A systematic procedure to correct for various distortions in the broad x-ray line profiles of glass-like carbons (GC) is described. The profile is first corrected for distortions due to low specimen absorption, secondly for incoherent (Compton) scattering, and then strong small angle scattering. The resulting profile is then multiplied by the appropriate trigonometric (Lorentz and polarization) factors. Finally, correction is made for the variation of the atomic scattering factor across the broad peaks. Two examples of the GC heat treatment at 1000 0 C and 2700 0 C have been used to illustrate the outcome of the corrections. 8 figures

  20. Assessment of bone mineral density with dual energy X-ray absorptiometry in pre-and post-menopausal women

    International Nuclear Information System (INIS)

    Salamat, M. R.; Rostampour, N.; Shanehsazzadeh, S.; Tavakoli, M. B.; Siavash, M.; Almasi, T.

    2008-01-01

    Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine in pre-and post-menopausal women from Isfahan Osteoporosis Diagnosis Center since 2005. Materials and Methods: Bone mineral density measurements using dual-energy X-ray absorptiometry have been performed at Isfahan Osteoporosis Diagnosis Center. 185 pre-menopausal and 174 early post-menopausal women were selected randomly. A Norland XR46 system was used for the investigations. The student t-lest was done to find the difference between the T-scores of the femoral neck and lumbar spine in pre-and post-menopausal women. Results: Mean Bone mineral density for the femoral neck and lumbar spine in pre-menopausal women were 0.859 ± 0.136 and 1.012 ± 0.161 and in post-menopausal women were 0.816 ± 0.119 and 0.919 ± 0.140, respectively. Long-term Bone mineral density CVs of 1.0% and 1.2% for the lumbar spine and femoral neck were found, respectively. The differences between the femoral neck and lumbar spine for pre-and post-menopausal women were t = -9.02, P < 0.05 and t = -3.50, P < 0.05, respectively. Conclusion: In spite of, the reported lower Bone mineral density T-scores for the lumbar spine compared With the femoral neck for women, we found that the femoral neck had significantly lower T-score than lumbar spine for both pre-and post-menopausal women.

  1. Rapid fusion of 2D X-ray fluoroscopy with 3D multislice CT for image-guided electrophysiology procedures

    Science.gov (United States)

    Zagorchev, Lyubomir; Manzke, Robert; Cury, Ricardo; Reddy, Vivek Y.; Chan, Raymond C.

    2007-03-01

    Interventional cardiac electrophysiology (EP) procedures are typically performed under X-ray fluoroscopy for visualizing catheters and EP devices relative to other highly-attenuating structures such as the thoracic spine and ribs. These projections do not however contain information about soft-tissue anatomy and there is a recognized need for fusion of conventional fluoroscopy with pre-operatively acquired cardiac multislice computed tomography (MSCT) volumes. Rapid 2D-3D integration in this application would allow for real-time visualization of all catheters present within the thorax in relation to the cardiovascular anatomy visible in MSCT. We present a method for rapid fusion of 2D X-ray fluoroscopy with 3DMSCT that can facilitate EP mapping and interventional procedures by reducing the need for intra-operative contrast injections to visualize heart chambers and specialized systems to track catheters within the cardiovascular anatomy. We use hardware-accelerated ray-casting to compute digitally reconstructed radiographs (DRRs) from the MSCT volume and iteratively optimize the rigid-body pose of the volumetric data to maximize the similarity between the MSCT-derived DRR and the intra-operative X-ray projection data.

  2. Post-operative X-ray morphology: Joints

    International Nuclear Information System (INIS)

    Vogel, H.

    1987-01-01

    The description of X-ray findings after operations with the object of implanting protheses in joints makes up most of the contents of this book. The reconstruction of joints after trauma is only marginally dealt with. Among the various indications for implanting protheses, the replacement of joints destroyed by wear and trauma is the most important. Also considered were X-ray examinations after hallux-valgus operations and plastic surgery on hands and feet, as well as X-ray findings following operations on the lumbar part of the vertebral column (disc surgery). (orig./MG) [de

  3. 75 FR 78988 - Post-2014 Resource Pool-Loveland Area Projects, Allocation Procedures and Call for Applications

    Science.gov (United States)

    2010-12-17

    ... Administration (Western), a Federal power marketing agency of the Department of Energy (DOE), is publishing this... customers and for other appropriate purposes as determined by Western. These allocation procedures and call for applications, in conjunction with the Loveland Area Projects (LAP) Final Post-1989 Marketing Plan...

  4. Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study

    International Nuclear Information System (INIS)

    Haeusler, Uwe; Brix, Gunnar; Czarwinski, Renate

    2009-01-01

    The purpose of this study was to analyse the radiation exposure of medical staff from interventional x-ray procedures. Partial-body dose measurements were performed with thermoluminescent dosimeters (TLD) in 39 physicians and nine assistants conducting 73 interventional procedures of nine different types in 14 hospitals in Germany. Fluoroscopy time and the dose-area product (DAP) were recorded too. The median (maximum) equivalent body dose per procedure was 16 (2,500) μSv for an unshielded person; the partial-body dose per procedure was 2.8 (240) μSv to the eye lens, 4.1 (730) μSv to the thyroid, 44 (1,800) μSv to one of the feet and 75 (13,000) μSv to one of the hands. A weak correlation between fluoroscopy time or DAP and the mean TLD dose was observed. Generally, the doses were within an acceptable range from a radiation hygiene point of view. However, relatively high exposures were measured to the hand in some cases and could cause a partial-body dose above the annual dose limit of 500 mSv. Thus, the use of finger dosimeters is strongly recommended. (orig.)

  5. Update of X ray and gamma ray decay data standards for detector calibration and other applications. V. 2: Data selection, assessment and evaluation procedures

    International Nuclear Information System (INIS)

    2007-05-01

    Various factors such as source preparation and source detector geometry may affect the quality of measurements made with intrinsic germanium and other γ ray spectrometers. However, the accuracy of such measurements invariably depends on the accuracy of the efficiency versus energy calibration curve and hence on the accuracy of the decay data for the radionuclides from which calibration standard sources are prepared. Both half-lives and X and γ ray emission probabilities need to be known to good accuracy. The recommendations and report of this work are published in two volumes: Volume 1 - Recommended Decay Data, High Energy Gamma Ray Standards and Angular Correlation Coefficients; Volume 2 - Data Selection, Assessment and Evaluation Procedures. Volume 1 is a self-contained assembly of the recommended decay data covering half-lives and the X ray and γ ray emission probabilities of the selected radionuclides, and listings of various high energy γ ray standards and a set of angular correlation coefficients; these data are presented in a concise manner for rapid and easy access. More detailed technical features of the CRP are described in Volume 2, including the evaluation procedures adopted and extensive traceable explanations of the origins of the nuclear data used to produce the recommended values listed in Volume 1. This detail was judged to be essential in order to record and demonstrate the quality of the resulting data files and allow the reader to trace the origins of the nuclear data used to determine the recommended values. All evaluations were based on the available experimental data, supplemented with the judicious use of well established theory. Three types of data (half-lives, energies and emission probabilities) were compiled and evaluated (Annex II). Consideration was also given to the adoption of a number of prompt high energy γ rays from specific nuclear reactions (Annex III), as well as to using the γ-γ coincidence technique for efficiency

  6. Confocal soft X-ray scanning transmission microscopy: setup, alignment procedure and limitations

    International Nuclear Information System (INIS)

    Späth, Andreas; Raabe, Jörg; Fink, Rainer H.

    2015-01-01

    A conventional STXM setup has been upgraded with a second micro zone plate and aligned to confocal geometry. Two confocal geometries (in-line and off-axis) have been evaluated and a discussion on prospects and limitations is presented. Zone-plate-based scanning transmission soft X-ray microspectroscopy (STXM) is a well established technique for high-contrast imaging of sufficiently transparent specimens (e.g. ultrathin biological tissues, polymer materials, archaeometric specimens or magnetic thin films) with spatial resolutions in the regime of 20 nm and high spectroscopic or chemical sensitivity. However, due to the relatively large depth of focus of zone plates, the resolution of STXM along the optical axis so far stays unambiguously behind for thicker X-ray transparent specimens. This challenge can be addressed by the implementation of a second zone plate in the detection pathway of the beam, resulting in a confocal arrangement. Within this paper a first proof-of-principle study for a confocal STXM (cSTXM) and an elaborate alignment procedure in transmission and fluorescence geometry are presented. Based on first confocal soft X-ray micrographs of well known specimens, the advantage and limitation of cSTXM as well as further development potentials for future applications are discussed

  7. Confocal soft X-ray scanning transmission microscopy: setup, alignment procedure and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Späth, Andreas [Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Egerlandstraße 3, 91058 Erlangen (Germany); Raabe, Jörg [Paul Scherrer Institut, 5232 Villigen (Switzerland); Fink, Rainer H., E-mail: rainer.fink@fau.de [Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Egerlandstraße 3, 91058 Erlangen (Germany); Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Egerlandstraße 3, 91058 Erlangen (Germany)

    2015-01-01

    A conventional STXM setup has been upgraded with a second micro zone plate and aligned to confocal geometry. Two confocal geometries (in-line and off-axis) have been evaluated and a discussion on prospects and limitations is presented. Zone-plate-based scanning transmission soft X-ray microspectroscopy (STXM) is a well established technique for high-contrast imaging of sufficiently transparent specimens (e.g. ultrathin biological tissues, polymer materials, archaeometric specimens or magnetic thin films) with spatial resolutions in the regime of 20 nm and high spectroscopic or chemical sensitivity. However, due to the relatively large depth of focus of zone plates, the resolution of STXM along the optical axis so far stays unambiguously behind for thicker X-ray transparent specimens. This challenge can be addressed by the implementation of a second zone plate in the detection pathway of the beam, resulting in a confocal arrangement. Within this paper a first proof-of-principle study for a confocal STXM (cSTXM) and an elaborate alignment procedure in transmission and fluorescence geometry are presented. Based on first confocal soft X-ray micrographs of well known specimens, the advantage and limitation of cSTXM as well as further development potentials for future applications are discussed.

  8. Neutron, gamma ray and post-irradiation thermal annealing effects on power semiconductor switches

    International Nuclear Information System (INIS)

    Schwarze, G.E.; Frasca, A.J.

    1994-01-01

    The effects of neutrons and gamma rays on the electrical and switching characteristics of power semiconductor switches must be known and understood by the designer of the power conditioning, control, and transmission subsystem of space nuclear power systems. The SP-100 radiation requirements at 25 m from the nuclear source are a neutron fluence of 10 13 n/cm 2 and a gamma dose of 0.5 Mrads. Experimental data showing the effects of neutrons and gamma rays on the performance characteristics of power-type NPN Bipolar Junction Transistors (BJTs), Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs), and Static Induction Transistors (SITs) are given in this paper. These three types of devices were tested at radiation levels which met or exceeded the SP-100 requirements. For the SP-100 radiation requirements, the BJTs were found to be most sensitive to neutrons, the MOSFETs were most sensitive to gamma rays, and the SITs were only slightly sensitive to neutrons. Post-irradiation thermal anneals at 300 K and up to 425 K were done on these devices and the effectiveness of these anneals are also discussed

  9. Post-therapeutic imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Pollice, Saverio, E-mail: saveriopollice@hotmail.it [Department of Radiology and Neuroradiology, “L. Bonomo Hospital”, 76123 Andria, BT (Italy); Muto, Mario, E-mail: mutomar@tiscali.it [Department of Neuroradiology, “Cardarelli Hospital”, Naples (Italy); Scarabino, Tommaso, E-mail: tscarabino@hotmail.com [Department of Radiology and Neuroradiology, “L. Bonomo Hospital”, 76123 Andria, BT (Italy)

    2015-05-15

    Highlights: • This study is the result of collaboration between neuroradiologists and neurosurgeons. • Comparison between neuroimaging techniques to better evaluate the complications after treatment of the spin. • Evaluation of the imaging features of complications and definition of follow-up. - Abstract: Any surgical approach modifies the normal anatomical and functional arrangement of the segmental spine which is aimed, therefore image interpretation cannot ignore a correct set of knowledge in the field of anatomy, pathophysiology, drug compliance, interventional radiology and surgery. Neuroradiological imaging has an important role before surgery to direct the surgeon or interventional radiologist during the operation, both in post-surgery, where imaging examination can rightly evaluate properties and effects of the treatment and can detect potential complications as infections, abscess, bleeding, exuberant scar, mobilization and rupture of devices. The available methods of imaging are the X-rays (XR) made at least in two projections, Computed Tomography (CT) with MPR (multiplanar) and VR (volume rendering) reconstruction, and Magnetic Resonance (MR), often performed before and after contrast media injection. Imaging assessment of spine after surgery is complex and depends upon several factors, including surgical procedures and disease for which it was performed; biomechanical of the underlying cortical and cancellous bone findings; conditions of muscles, intervertebral disk and ligaments; time since surgery procedures; duration and nature of the post-surgical syndrome. Depending upon several factors, one or a combination of complementary imaging modalities (X-rays, Computed Tomography, Magnetic Resonance) may be required to evaluate effectiveness of the treatment; to demonstrate any clinically relevant abnormality at the treated region and adjacent structures (complications such as inflammation, abscesses, bleeding and misplacement of the device); to

  10. Post-therapeutic imaging findings

    International Nuclear Information System (INIS)

    Pollice, Saverio; Muto, Mario; Scarabino, Tommaso

    2015-01-01

    Highlights: • This study is the result of collaboration between neuroradiologists and neurosurgeons. • Comparison between neuroimaging techniques to better evaluate the complications after treatment of the spin. • Evaluation of the imaging features of complications and definition of follow-up. - Abstract: Any surgical approach modifies the normal anatomical and functional arrangement of the segmental spine which is aimed, therefore image interpretation cannot ignore a correct set of knowledge in the field of anatomy, pathophysiology, drug compliance, interventional radiology and surgery. Neuroradiological imaging has an important role before surgery to direct the surgeon or interventional radiologist during the operation, both in post-surgery, where imaging examination can rightly evaluate properties and effects of the treatment and can detect potential complications as infections, abscess, bleeding, exuberant scar, mobilization and rupture of devices. The available methods of imaging are the X-rays (XR) made at least in two projections, Computed Tomography (CT) with MPR (multiplanar) and VR (volume rendering) reconstruction, and Magnetic Resonance (MR), often performed before and after contrast media injection. Imaging assessment of spine after surgery is complex and depends upon several factors, including surgical procedures and disease for which it was performed; biomechanical of the underlying cortical and cancellous bone findings; conditions of muscles, intervertebral disk and ligaments; time since surgery procedures; duration and nature of the post-surgical syndrome. Depending upon several factors, one or a combination of complementary imaging modalities (X-rays, Computed Tomography, Magnetic Resonance) may be required to evaluate effectiveness of the treatment; to demonstrate any clinically relevant abnormality at the treated region and adjacent structures (complications such as inflammation, abscesses, bleeding and misplacement of the device); to

  11. Deformable registration of x-ray to MRI for post-implant dosimetry in prostate brachytherapy

    Science.gov (United States)

    Park, Seyoun; Song, Danny Y.; Lee, Junghoon

    2016-03-01

    Post-implant dosimetric assessment in prostate brachytherapy is typically performed using CT as the standard imaging modality. However, poor soft tissue contrast in CT causes significant variability in target contouring, resulting in incorrect dose calculations for organs of interest. CT-MR fusion-based approach has been advocated taking advantage of the complementary capabilities of CT (seed identification) and MRI (soft tissue visibility), and has proved to provide more accurate dosimetry calculations. However, seed segmentation in CT requires manual review, and the accuracy is limited by the reconstructed voxel resolution. In addition, CT deposits considerable amount of radiation to the patient. In this paper, we propose an X-ray and MRI based post-implant dosimetry approach. Implanted seeds are localized using three X-ray images by solving a combinatorial optimization problem, and the identified seeds are registered to MR images by an intensity-based points-to-volume registration. We pre-process the MR images using geometric and Gaussian filtering. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine transformation and local deformable registration. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. We tested our algorithm on six patient data sets, achieving registration error of (1.2+/-0.8) mm in < 30 sec. Our proposed approach has the potential to be a fast and cost-effective solution for post-implant dosimetry with equivalent accuracy as the CT-MR fusion-based approach.

  12. Calibration and correction procedures for cosmic-ray neutron soil moisture probes located across Australia

    Science.gov (United States)

    Hawdon, Aaron; McJannet, David; Wallace, Jim

    2014-06-01

    The cosmic-ray probe (CRP) provides continuous estimates of soil moisture over an area of ˜30 ha by counting fast neutrons produced from cosmic rays which are predominantly moderated by water molecules in the soil. This paper describes the setup, measurement correction procedures, and field calibration of CRPs at nine locations across Australia with contrasting soil type, climate, and land cover. These probes form the inaugural Australian CRP network, which is known as CosmOz. CRP measurements require neutron count rates to be corrected for effects of atmospheric pressure, water vapor pressure changes, and variations in incoming neutron intensity. We assess the magnitude and importance of these corrections and present standardized approaches for network-wide analysis. In particular, we present a new approach to correct for incoming neutron intensity variations and test its performance against existing procedures used in other studies. Our field calibration results indicate that a generalized calibration function for relating neutron counts to soil moisture is suitable for all soil types, with the possible exception of very sandy soils with low water content. Using multiple calibration data sets, we demonstrate that the generalized calibration function only applies after accounting for persistent sources of hydrogen in the soil profile. Finally, we demonstrate that by following standardized correction procedures and scaling neutron counting rates of all CRPs to a single reference location, differences in calibrations between sites are related to site biomass. This observation provides a means for estimating biomass at a given location or for deriving coefficients for the calibration function in the absence of field calibration data.

  13. WE-AB-BRA-12: Post-Implant Dosimetry in Prostate Brachytherapy by X-Ray and MRI Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Song, D; Lee, J [Johns Hopkins University, Baltimore, MD (United States); Le, Y [Indiana University, Indianapolis, IN (United States)

    2016-06-15

    Purpose: For post-implant dosimetric assessment after prostate brachytherapy, CT-MR fusion approach has been advocated due to the superior accuracy on both seeds localization and soft tissue delineation. However, CT deposits additional radiation to the patient, and seed identification in CT requires manual review and correction. In this study, we propose an accurate, low-dose, and cost-effective post-implant dosimetry approach based on X-ray and MRI. Methods: Implanted seeds are reconstructed using only three X-ray fluoroscopy images by solving a combinatorial optimization problem. The reconstructed seeds are then registered to MR images using an intensity-based points-to-volume registration. MR images are first pre-processed by geometric and Gaussian filtering, yielding smooth candidate seed-only images. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine followed by local deformable registrations. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. Results: We tested our algorithm on twenty patient data sets. For quantitative evaluation, we obtained ground truth seed positions by fusing the post-implant CT-MR images. Seeds were semi-automatically extracted from CT and manually corrected and then registered to the MR images. Target registration error (TRE) was computed by measuring the Euclidean distances from the ground truth to the closest registered X-ray seeds. The overall TREs (mean±standard deviation in mm) are 1.6±1.1 (affine) and 1.3±0.8 (affine+deformable). The overall computation takes less than 1 minute. Conclusion: It has been reported that the CT-based seed localization error is ∼1.6mm and the seed localization uncertainty of 2mm results in less than 5% deviation of prostate D

  14. WE-AB-BRA-12: Post-Implant Dosimetry in Prostate Brachytherapy by X-Ray and MRI Fusion

    International Nuclear Information System (INIS)

    Park, S; Song, D; Lee, J; Le, Y

    2016-01-01

    Purpose: For post-implant dosimetric assessment after prostate brachytherapy, CT-MR fusion approach has been advocated due to the superior accuracy on both seeds localization and soft tissue delineation. However, CT deposits additional radiation to the patient, and seed identification in CT requires manual review and correction. In this study, we propose an accurate, low-dose, and cost-effective post-implant dosimetry approach based on X-ray and MRI. Methods: Implanted seeds are reconstructed using only three X-ray fluoroscopy images by solving a combinatorial optimization problem. The reconstructed seeds are then registered to MR images using an intensity-based points-to-volume registration. MR images are first pre-processed by geometric and Gaussian filtering, yielding smooth candidate seed-only images. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine followed by local deformable registrations. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. Results: We tested our algorithm on twenty patient data sets. For quantitative evaluation, we obtained ground truth seed positions by fusing the post-implant CT-MR images. Seeds were semi-automatically extracted from CT and manually corrected and then registered to the MR images. Target registration error (TRE) was computed by measuring the Euclidean distances from the ground truth to the closest registered X-ray seeds. The overall TREs (mean±standard deviation in mm) are 1.6±1.1 (affine) and 1.3±0.8 (affine+deformable). The overall computation takes less than 1 minute. Conclusion: It has been reported that the CT-based seed localization error is ∼1.6mm and the seed localization uncertainty of 2mm results in less than 5% deviation of prostate D

  15. Post-irradiation examination of a fuel pin using a microscopic X-ray system: Measurement of carbon deposition and pin metrology

    International Nuclear Information System (INIS)

    Gras, Ch.; Stanley, S.J.

    2008-01-01

    The paper presents some interesting aspects associated with X-ray imaging and its potential application in the nuclear industry. The feasibility of using X-ray technology for the post-irradiation examination of a fuel pin has been explored, more specifically pin metrology and carbon deposition measurement. The non-active sample was specially designed to mimic the structure of an AGR fuel pin whilst a carbon based material was applied to the mock up fuel rod in order to mimic carbon deposition. Short duration low energy (50 kV) 2D digital radiography was employed and provided encouraging results (with respect to carbon deposition thickness and structure measurements) for the mock up fuel pin with a spatial resolution of around 10 μm. Obtaining quantitative data from the resultant images is the principal added value associated with X-ray imaging. A higher intensity X-ray beam (≥90 kV) was also used in conjunction with the low energy set-up to produce a clear picture of the cladding as well as the interface between the lead (Pb mimics the uranium oxide) and stainless steel cladding. Spent fuel metrology and routine radiography are two additional tasks that X-ray imaging could perform for the post-irradiation examination programme. Therefore, when compared to other techniques developed to deliver information on one particular parameter, X-ray imaging offers the possibility to extract useful information on a range of parameters

  16. A generalized ray-tracing procedure for an atmospheric Cherenkov imaging telescope and optical characteristics of the TACTIC light collector

    International Nuclear Information System (INIS)

    Tickoo, A.K.; Suthar, R.L.; Koul, R.; Sapru, M.L.; Kumar, N.; Kaul, C.L.; Yadav, K.K.; Thoudam, S.; Kaul, S.K.; Venugopal, K.; Kothari, M.; Goyal, H.C.; Chandra, P.; Dhar, V.K.; Rannot, R.C.; Koul, M.K.; Kaul, S.R.

    2005-01-01

    A generalized ray-tracing procedure has been developed, which facilitates the design of a multimirror-based light collector used in atmospheric Cherenkov telescopes. This procedure has been employed to study the optical characteristics of the 3.5 m diameter light collector of the TACTIC Imaging telescope. Comparison of the measured point-spread function of the light collector with the simulated performance of ideal Davies-Cotton and paraboloid designs has been made to determine an optimum arrangement of the 34 spherical mirror facets used in the telescope to obtain the best possible point-spread function. A description of the ray-tracing subroutine used for processing CORSIKA-generated Cherenkov data, required for carrying out Monte-Carlo simulation studies, is also discussed in the paper

  17. Suitable post processing algorithms for X-ray imaging using oversampled displaced multiple images

    International Nuclear Information System (INIS)

    Thim, J; Reza, S; Nawaz, K; Norlin, B; O'Nils, M; Oelmann, B

    2011-01-01

    X-ray imaging systems such as photon counting pixel detectors have a limited spatial resolution of the pixels, based on the complexity and processing technology of the readout electronics. For X-ray imaging situations where the features of interest are smaller than the imaging system pixel size, and the pixel size cannot be made smaller in the hardware, alternative means of resolution enhancement require to be considered. Oversampling with the usage of multiple displaced images, where the pixels of all images are mapped to a final resolution enhanced image, has proven a viable method of reaching a sub-pixel resolution exceeding the original resolution. The effectiveness of the oversampling method declines with the number of images taken, the sub-pixel resolution increases, but relative to a real reduction of imaging pixel sizes yielding a full resolution image, the perceived resolution from the sub-pixel oversampled image is lower. This is because the oversampling method introduces blurring noise into the mapped final images, and the blurring relative to full resolution images increases with the oversampling factor. One way of increasing the performance of the oversampling method is by sharpening the images in post processing. This paper focus on characterizing the performance increase of the oversampling method after the use of some suitable post processing filters, for digital X-ray images specifically. The results show that spatial domain filters and frequency domain filters of the same type yield indistinguishable results, which is to be expected. The results also show that the effectiveness of applying sharpening filters to oversampled multiple images increase with the number of images used (oversampling factor), leaving 60-80% of the original blurring noise after filtering a 6 x 6 mapped image (36 images taken), where the percentage is depending on the type of filter. This means that the effectiveness of the oversampling itself increase by using sharpening

  18. Gastro-pancreaticojejunostomy for treatment of pancreatic ductal obstruction in a post-Whipple procedure patient.

    Science.gov (United States)

    Rodrigues-Pinto, Eduardo; Grimm, Ian S; Baron, Todd H

    2015-01-01

    We report a case of a woman with a medical history of classic Whipple surgery who underwent endoscopic ultrasound (EUS)-guided pancreatic drainage due to smouldering acute pancreatitis secondary to an obstructing pancreatic ductal stone. A gastro-pancreaticojejunostomy anastomosis was created anterogradely, with dilation of both the anastomoses in the same procedure, with subsequent decompression of the pancreatic duct. Endoscopic retrograde pancreatography (ERP) is often impossible to perform in patients with post-Whipple procedure anatomy due to inaccessibility to the pancreaticojejunostomy anastomosis. EUS-guided pancreatic drainage may be offered in these patients in whom the pancreatic duct cannot be accessed at ERP. It has been used as a platform for access to and drainage of the pancreatic duct either by rendezvous or transmural drainage. However, only one of four patients achieve successful completion of the rendezvous procedure. There are limited data regarding safety and long-term outcome of this procedure, as well as scant guidelines on the optimal time for leaving stents in place. We believe definitive endoscopic therapy should be attempted, whenever possible, after relief of obstruction. In our case, we expect that stent occlusion is inevitable and that long-term drainage is possible due to drainage occurring between the stent and the stone.

  19. Photographic paper X-ray procedure - a simple technique for the visualisation of osseous norm variations and malformations

    International Nuclear Information System (INIS)

    Markert, K.; Wirth, I.; Reinhold-Richter, L.

    1983-01-01

    On the basis of osseous norm variations and malformations, a simple X-ray procedure by means of photographic paper which can be applied in every institute of pathology is demonstrated. The quality of the photographs permits the assessment of skeletal changes which are of diagnostic importance. (author)

  20. Post Implementation Review Framework and Procedures

    Data.gov (United States)

    Social Security Administration — This template outlines the Social Security Administration's (SSA) approach to initiating, conducting, and completing Post Implementation Reviews (PIRs). The template...

  1. Risk analysis procedure for post-wildfire natural hazards in British Columbia

    Science.gov (United States)

    Jordan, Peter

    2010-05-01

    Following a severe wildfire season in 2003, and several subsequent damaging debris flow and flood events, the British Columbia Forest Service developed a procedure for analysing risks to public safety and infrastructure from such events. At the same time, the Forest Service undertook a research program to determine the extent of post-wildfire hazards, and examine the hydrologic and geomorphic processes contributing to the hazards. The risk analysis procedure follows the Canadian Standards Association decision-making framework for risk management (which in turn is based on international standards). This has several steps: identification of risk, risk analysis and estimation, evaluation of risk tolerability, developing control or mitigation strategies, and acting on these strategies. The Forest Service procedure deals only with the first two steps. The results are passed on to authorities such as the Provincial Emergency Program and local government, who are responsible for evaluating risks, warning residents, and applying mitigation strategies if appropriate. The objective of the procedure is to identify and analyse risks to public safety and infrastructure. The procedure is loosely based on the BAER (burned area emergency response) program in the USA, with some important differences. Our procedure focuses on identifying risks and warning affected parties, not on mitigation activities such as broadcast erosion control measures. Partly this is due to limited staff and financial resources. Also, our procedure is not multi-agency, but is limited to wildfires on provincial forest land; in British Columbia about 95% of forest land is in the publicly-owned provincial forest. Each fire season, wildfires are screened by size and proximity to values at risk such as populated areas. For selected fires, when the fire is largely contained, the procedure begins with an aerial reconnaissance of the fire, and photography with a hand-held camera, which can be used to make a

  2. A revised partiality model and post-refinement algorithm for X-ray free-electron laser data

    Energy Technology Data Exchange (ETDEWEB)

    Ginn, Helen Mary [Wellcome Trust Centre for Human Genetics, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Brewster, Aaron S.; Hattne, Johan [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Evans, Gwyndaf; Wagner, Armin [Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0QX (United Kingdom); Grimes, Jonathan M. [Wellcome Trust Centre for Human Genetics, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0QX (United Kingdom); Sauter, Nicholas K. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Sutton, Geoff [Wellcome Trust Centre for Human Genetics, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Stuart, David Ian, E-mail: dave@strubi.ox.ac.uk [Wellcome Trust Centre for Human Genetics, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0QX (United Kingdom)

    2015-05-23

    An updated partiality model and post-refinement algorithm for XFEL snapshot diffraction data is presented and confirmed by observing anomalous density for S atoms at an X-ray wavelength of 1.3 Å. Research towards using X-ray free-electron laser (XFEL) data to solve structures using experimental phasing methods such as sulfur single-wavelength anomalous dispersion (SAD) has been hampered by shortcomings in the diffraction models for X-ray diffraction from FELs. Owing to errors in the orientation matrix and overly simple partiality models, researchers have required large numbers of images to converge to reliable estimates for the structure-factor amplitudes, which may not be feasible for all biological systems. Here, data for cytoplasmic polyhedrosis virus type 17 (CPV17) collected at 1.3 Å wavelength at the Linac Coherent Light Source (LCLS) are revisited. A previously published definition of a partiality model for reflections illuminated by self-amplified spontaneous emission (SASE) pulses is built upon, which defines a fraction between 0 and 1 based on the intersection of a reflection with a spread of Ewald spheres modelled by a super-Gaussian wavelength distribution in the X-ray beam. A method of post-refinement to refine the parameters of this model is suggested. This has generated a merged data set with an overall discrepancy (by calculating the R{sub split} value) of 3.15% to 1.46 Å resolution from a 7225-image data set. The atomic numbers of C, N and O atoms in the structure are distinguishable in the electron-density map. There are 13 S atoms within the 237 residues of CPV17, excluding the initial disordered methionine. These only possess 0.42 anomalous scattering electrons each at 1.3 Å wavelength, but the 12 that have single predominant positions are easily detectable in the anomalous difference Fourier map. It is hoped that these improvements will lead towards XFEL experimental phase determination and structure determination by sulfur SAD and will

  3. Introducing GAMER: A Fast and Accurate Method for Ray-tracing Galaxies Using Procedural Noise

    Science.gov (United States)

    Groeneboom, N. E.; Dahle, H.

    2014-03-01

    We developed a novel approach for fast and accurate ray-tracing of galaxies using procedural noise fields. Our method allows for efficient and realistic rendering of synthetic galaxy morphologies, where individual components such as the bulge, disk, stars, and dust can be synthesized in different wavelengths. These components follow empirically motivated overall intensity profiles but contain an additional procedural noise component that gives rise to complex natural patterns that mimic interstellar dust and star-forming regions. These patterns produce more realistic-looking galaxy images than using analytical expressions alone. The method is fully parallelized and creates accurate high- and low- resolution images that can be used, for example, in codes simulating strong and weak gravitational lensing. In addition to having a user-friendly graphical user interface, the C++ software package GAMER is easy to implement into an existing code.

  4. Introducing GAMER: A fast and accurate method for ray-tracing galaxies using procedural noise

    International Nuclear Information System (INIS)

    Groeneboom, N. E.; Dahle, H.

    2014-01-01

    We developed a novel approach for fast and accurate ray-tracing of galaxies using procedural noise fields. Our method allows for efficient and realistic rendering of synthetic galaxy morphologies, where individual components such as the bulge, disk, stars, and dust can be synthesized in different wavelengths. These components follow empirically motivated overall intensity profiles but contain an additional procedural noise component that gives rise to complex natural patterns that mimic interstellar dust and star-forming regions. These patterns produce more realistic-looking galaxy images than using analytical expressions alone. The method is fully parallelized and creates accurate high- and low- resolution images that can be used, for example, in codes simulating strong and weak gravitational lensing. In addition to having a user-friendly graphical user interface, the C++ software package GAMER is easy to implement into an existing code.

  5. Introducing GAMER: A fast and accurate method for ray-tracing galaxies using procedural noise

    Energy Technology Data Exchange (ETDEWEB)

    Groeneboom, N. E.; Dahle, H., E-mail: nicolaag@astro.uio.no [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, N-0315 Oslo (Norway)

    2014-03-10

    We developed a novel approach for fast and accurate ray-tracing of galaxies using procedural noise fields. Our method allows for efficient and realistic rendering of synthetic galaxy morphologies, where individual components such as the bulge, disk, stars, and dust can be synthesized in different wavelengths. These components follow empirically motivated overall intensity profiles but contain an additional procedural noise component that gives rise to complex natural patterns that mimic interstellar dust and star-forming regions. These patterns produce more realistic-looking galaxy images than using analytical expressions alone. The method is fully parallelized and creates accurate high- and low- resolution images that can be used, for example, in codes simulating strong and weak gravitational lensing. In addition to having a user-friendly graphical user interface, the C++ software package GAMER is easy to implement into an existing code.

  6. DNA microarray analyses reveal a post-irradiation differential time-dependent gene expression profile in yeast cells exposed to X-rays and gamma-rays.

    Science.gov (United States)

    Kimura, Shinzo; Ishidou, Emi; Kurita, Sakiko; Suzuki, Yoshiteru; Shibato, Junko; Rakwal, Randeep; Iwahashi, Hitoshi

    2006-07-21

    Ionizing radiation (IR) is the most enigmatic of genotoxic stress inducers in our environment that has been around from the eons of time. IR is generally considered harmful, and has been the subject of numerous studies, mostly looking at the DNA damaging effects in cells and the repair mechanisms therein. Moreover, few studies have focused on large-scale identification of cellular responses to IR, and to this end, we describe here an initial study on the transcriptional responses of the unicellular genome model, yeast (Saccharomyces cerevisiae strain S288C), by cDNA microarray. The effect of two different IR, X-rays, and gamma (gamma)-rays, was investigated by irradiating the yeast cells cultured in YPD medium with 50 Gy doses of X- and gamma-rays, followed by resuspension of the cells in YPD for time-course experiments. The samples were collected for microarray analysis at 20, 40, and 80 min after irradiation. Microarray analysis revealed a time-course transcriptional profile of changed gene expressions. Up-regulated genes belonged to the functional categories mainly related to cell cycle and DNA processing, cell rescue defense and virulence, protein and cell fate, and metabolism (X- and gamma-rays). Similarly, for X- and gamma-rays, the down-regulated genes belonged to mostly transcription and protein synthesis, cell cycle and DNA processing, control of cellular organization, cell fate, and C-compound and carbohydrate metabolism categories, respectively. This study provides for the first time a snapshot of the genome-wide mRNA expression profiles in X- and gamma-ray post-irradiated yeast cells and comparatively interprets/discusses the changed gene functional categories as effects of these two radiations vis-à-vis their energy levels.

  7. Enhancement of gamma-ray-induced mutation frequency in rice by post-treatment with chloral hydrate, methanol and their mixtures with ethanol

    International Nuclear Information System (INIS)

    Reddy, T.P.; Vaidyanath, K.

    1979-01-01

    An evaluation has been made of the mutagenic activity of ethanol, chlorate hydrate (CH) and methanol on rice seed. In independent treatments with ethanol, methanol, CH and four aqueous mixtures of these chemicals, chlorophyll-deficient mutants were not recovered in the M 2 generation. However, in sequential treatments with gamma rays + CH, gamma rays + methanol and gamma rays + aqueous mixtures of these chemicals, significant increases in the yields of chlorophyll mutations were observed as compared to that of a 30 kR gamma ray treatment. In contrast, post-irradiation treatment with ethanol failed to provoke any increase in the frequency of chlorophyll mutants in the M 2 generation. The results indicate that CH and methanol alone and mixed with ethanol can potentiate gamma ray-induced genetic lesions in rice seed. (author)

  8. Radiation dose to procedural personnel and patients from an X-ray volume imaging system

    International Nuclear Information System (INIS)

    Paul, Jijo; Mbalisike, Emmanuel C.; Vogl, Thomas J.

    2013-01-01

    To evaluate the radiation dose received by procedural personnel and patients from an X-ray volume imaging (XVI) system during interventional procedures. Forty patients were examined using catheter angiography (group A), digital subtraction angiography (group B) and cone-beam CT (CBCT, group C). Doses to procedural personnel (using thermo-luminescent dosimeters, TLDs) and patients were estimated. Image quality and lesion delineation were assessed using objective and subjective methods. Shapiro-Wilk, two-sided Student's t and Wilcoxon matched-pairs tests were used to test statistical significance. Doses (milligrays) measured in the hands and left knee of the interventionist were higher than those in an assistant physician (P < 0.05). Doses (dose-area product and skin entry dose) were lower in group A and higher in C compared with other groups; moreover, comparison among the groups were significant (all P = 0.0001). Subjective and objective lesion delineation showed significant results (all P < 0.05) among the tumour types considered. Image quality estimation showed the opposite results for objective and subjective analysis. More doses were obtained for hands of the procedural personnel compared to other anatomical regions measured. Catheter angiography showed lower dose compared with other imaging groups examined. Lesion delineation was clearly possible using CBCT. Objective and subjective analysis showed the opposite results regarding image quality because of higher noise levels and artefacts. (orig.)

  9. Safety code 19: recommended safety procedures for the selection, installation and use of x-ray diffraction equipment

    International Nuclear Information System (INIS)

    1984-01-01

    This document is one of a series of Safety Codes prepared by the Radiation Protection Bureau to set out requirements for the safe use of radiation emitting devices. The equipment and installation guidelines and safety procedures detailed in this Code are primarily for the instruction and guidance of persons employed in Federal Public Service Departments and Agencies, as well as those coming under the jurisdiction of the Canada Labour Code. This Safety Code is also intended to assist other users of X-ray diffraction equipment to select safe equipment and to install and use it so that the radiation hazard to the operator and other persons in its vicinity is negligible. It should be noted that facilities under provincial jurisdiction may be subject to requirements specified under provincial statutes. This Code supersedes Safety Code RPD-SC-7, entitled 'Requirements For Non-Medical X-Ray Equipment, Use and Installation', insofar as X-ray diffraction equipment is concerned, and it is intended to complement X-ray equipment design, construction and performance standards promulgated under the Radiation Emitting Devices Act

  10. Induction of congenital malformations in the offspring of male mice treated with X-rays at pre-meiotic and post-meiotic stages

    International Nuclear Information System (INIS)

    Kirk, K.M.; Lyon, M.F.

    1984-01-01

    The induction of congenital malformations among the offspring of male mice treated with X-rays at pre-meiotic and post-meiotic stages has been studied in two experiments. Firstly, animals were exposed to varying doses of X-rays and mated at various time intervals, so as to sample spermatozoa, spermatids and spermatogonial stem cells. In the second experiment, only treated spermatogonial stem cells were sampled. One group of males was given a single dose, a second group a fractionated dose and a third group was left unexposed. In the first experiment, induced post-implantation dominant lethality increased with dose, and was highest in week 3, in line with the known greater radiosensitivity of the early spermatid stage. Preimplantation loss also increased with dose and was highest in week 3. There was no clear induction of either pre-implantation or post-implantation loss at spermatogonial stem cell stages. There was a clear induction of congenital malformations at post-meiotic stages. At the two highest doses the early spermatids (15-21 days) appeared more sensitive than spermatozoa, and at this stage the incidence of malformations increased with dose. Expt. 2 showed a statistically significant induction of malformations at both dose levels. The relative sensitivities of male stem cells, post-meiotic stages and mature oocytes to the induction of congenital malformations were reasonably similar to their sensitivities for specific-locus mutations, except that the expected enhancing effect of the fractionation regime used was not seen. (Auth.)

  11. Induction of congenital malformations in the offspring of male mice treated with X-rays at pre-meiotic and post-meiotic stages

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, K.M.; Lyon, M.F. (Medical Research Council, Harwell (UK). Radiobiological Research Unit)

    1984-01-01

    The induction of congenital malformations among the offspring of male mice treated with X-rays at pre-meiotic and post-meiotic stages has been studied in two experiments. Firstly, animals were exposed to varying doses of X-rays and mated at various time intervals, so as to sample spermatozoa, spermatids and spermatogonial stem cells. In the second experiment, only treated spermatogonial stem cells were sampled. One group of males was given a single dose, a second group a fractionated dose and a third group was left unexposed. In the first experiment, induced post-implantation dominant lethality increased with dose, and was highest in week 3, in line with the known greater radiosensitivity of the early spermatid stage. Preimplantation loss also increased with dose and was highest in week 3. There was no clear induction of either pre-implantation or post-implantation loss at spermatogonial stem cell stages. There was a clear induction of congenital malformations at post-meiotic stages. At the two highest doses the early spermatids (15-21 days) appeared more sensitive than spermatozoa, and at this stage the incidence of malformations increased with dose. Expt. 2 showed a statistically significant induction of malformations at both dose levels. The relative sensitivities of male stem cells, post-meiotic stages and mature oocytes to the induction of congenital malformations were reasonably similar to their sensitivities for specific-locus mutations, except that the expected enhancing effect of the fractionation regime used was not seen.

  12. An improved ring removal procedure for in-line x-ray phase contrast tomography

    Science.gov (United States)

    Massimi, Lorenzo; Brun, Francesco; Fratini, Michela; Bukreeva, Inna; Cedola, Alessia

    2018-02-01

    The suppression of ring artifacts in x-ray computed tomography (CT) is a required step in practical applications; it can be addressed by introducing refined digital low pass filters within the reconstruction process. However, these filters may introduce additional ringing artifacts when simultaneously imaging pure phase objects and elements having a non-negligible absorption coefficient. Ringing originates at sharp interfaces, due to the truncation of spatial high frequencies, and severely affects qualitative and quantitative analysis of the reconstructed slices. In this work, we discuss the causes of ringing artifacts, and present a general compensation procedure to account for it. The proposed procedure has been tested with CT datasets of the mouse central nervous system acquired at different synchrotron radiation facilities. The results demonstrate that the proposed method compensates for ringing artifacts induced by low pass ring removal filters. The effectiveness of the ring suppression filters is not altered; the proposed method can thus be considered as a framework to improve the ring removal step, regardless of the specific filter adopted or the imaged sample.

  13. Positron emission CT on post-traumatic epilepsy

    International Nuclear Information System (INIS)

    Tsukiyama, Takashi; Tsubokawa, Takashi; Doi, Nobuyasu; Sato, Kohten; Iio, Masaaki.

    1983-01-01

    Six patients suffering from post-traumatic epilepsy were checked by encephalography (EEG), X-ray CT and cerebral positron emission computed tomography (PECT) using 11 C-carbon dioxide ( 11 CO 2 ) and 11 C-glucoses as indicators of the local cerebral circulation and local cerebral glucose utilization, in order to assess the diagnostic value of PECT in post-traumatic epilepsy. In those patients (4 cases) who had focal electrical abnormalities or X-ray CT lesions, PECT clearly revealed localized regions of decreased cerebral circulation and glucose utilization. A focal hypometabolic zone also appeared in the post-traumatic epilepsy (1 case) which had a normal X-ray CT. One case, who had been treated for several years by medication but showed no EEG change and no abnormality on X-ray CT, revealed a normal circulation and metabolism by RECT. This case did not require any further medication for epilepsy. It is concluded that positron emission CT represents a useful diagnostic method for post-traumatic epilepsy which does not demonstrate any abnormality on X-ray CT. (author)

  14. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel

  15. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel.

  16. Survey of effective doses to patients undergoing contrast-based X-ray fluoroscopy procedures in Tanzania

    International Nuclear Information System (INIS)

    Ngaile, J.E.; Msaki, P.K.; Kazema, R.R.

    2017-01-01

    The aim of this study was to assess the radiation burden imparted to patients from contrast-based X-ray fluoroscopy procedures in Tanzania. The effective doses (EDs) to patients from five contrast-based fluoroscopy procedures were obtained from four hospitals. The ED was estimated using the knowledge of the patient characteristics, patient-related exposure parameters, measurements of air kerma area product and PCXCM software. The median EDs for the barium swallow (BS), barium meal (BM), barium enema (BE), hysterosalpingography (HSG) and retrograde urethrography (RUG) were 0.50, 1.43, 2.83, 0.65 and 0.59 mSv, respectively. The median ED per hospital for the BS and BM procedures varied by factors of up to 9.9 and 4.2, respectively, while for the BE, HSG and RUG varied by factors of up to 2.3, 2.4 and 4.3, respectively. The overall differences between individual EDs across the four hospitals varied by factors of up to 53, 58.9 and 11.4 for the BS, BM and BE, respectively, while for the HSG and RUG differed by factors of up to 22 and 46.7, respectively. The mean EDs in this study were mostly lower than reported values from Spain, the UK, Ghana and Greece, while slightly higher than those reported from India. The observed wide variations of procedural protocols and patient doses within and across the hospitals; and the observed high patient doses in this study relative to those from the literature call for the need to standardize procedural protocols and optimize contrast-based fluoroscopy procedures. (authors)

  17. Procedure for the record, calculation and analysis of costs at the Post Company of Cuba.

    Directory of Open Access Journals (Sweden)

    María Luisa Lara Zayas

    2012-12-01

    Full Text Available The Cuban Company is immersed in important changes, which lead to a new economic model that requires to increase the productivity of work and to enlarge the economic efficiency by means of rational use of material resources, financial and humans. In the present work it is proposed a procedure based on the application of cost techniques, for the record, calculation and costs analysis of activities in the Post Company of Cuba in Sancti Spiritus with the objective to obtain a major efficiency from the rational use of resources.

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  19. On the methods of determination of x-ray sources protection quality in x-ray diagnostic equipment

    International Nuclear Information System (INIS)

    Vladimirov, L.V.

    1973-01-01

    Existing procedures for assessing the quality of shielding of X-ray radiators are compared; these procedures are shown to have a number of shortcomings and to be very time-consuming. A procedure is offered in which shielding quality is tested in two stages: (1) X-ray tests aimed at determining the quality of protection of the X-ray tube unit; and (2) dosimeter tests proper. The results of measurements are compared with maximum permissible dosage rate

  20. Chest X-Ray

    Medline Plus

    Full Text Available ... X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey Rubin, a radiologist ... about chest x-rays, visit Radiology Info dot org. Thank you for your time! Spotlight Recently posted: ...

  1. The analysis, by a fusion procedure and X-ray-fluorescence spectrometry, of silicates and slags

    International Nuclear Information System (INIS)

    Jacobs, J.J.; Balaes, A.M.E.

    1980-01-01

    A glass-disc fusion method is described for the analysis, by X-ray-fluorescence spectrometry, of slags and silicate materials. The data are corrected for detector dead time and short-term instrumental drift. Corrections are made for matrix variations by use of the Lachange-Traill mathematical model, and the results are processed on a mini-computer, an iterative procedure being used in the solving of the simultaneous equations. As the alpha-correction coefficients of the Lachange-Traill model are not truly constant, a modified version of the model is proposed [af

  2. 47 CFR 1.1604 - Post-selection hearings.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Post-selection hearings. 1.1604 Section 1.1604 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL PRACTICE AND PROCEDURE Random Selection Procedures for Mass Media Services General Procedures § 1.1604 Post-selection hearings. (a) Following the random...

  3. Post procedure headache in patients treated for neurovascular arteriovenous malformations and aneurysms using endovascular therapy.

    Science.gov (United States)

    Khan, Sabrina; Amin, Faisal Mohammad; Hauerberg, John; Holtmannspötter, Markus; Petersen, Julie Falkenberg; Fakhril-Din, Zainab; Gaist, David; Ashina, Messoud

    2016-12-01

    Though endovascular therapy (EVT) is increasingly applied in the treatment of intracranial vascular lesions, little is known about the effect of EVT on post-procedure headache. We aimed to investigate the prevalence of headache in patients who have undergone EVT for cerebral arteriovenous malformations (AVMs) and aneurysms. A total of 324 patients underwent EVT treatment for aneurysms and AVMs at the Danish National Hospital from January 2012 to December 2014. We applied strict exclusion criteria in order to minimize the effect of other factors on headache occurrence, e.g., craniotomy. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire. Headaches were classified according to ICHD-III beta criteria. The 59 patients underwent treatment of aneurysms (n = 43), cranial dural fistulas (n = 11), and AVMs (n = 5). There was a significant increase in overall headache (p = 0.017) and tension-type headache (TTH) (p = 0.012) within the first 3 months after EVT compared to 1 month before EVT. However, at interview time (median 2.5 years post-EVT), the increase in overall headache, migraine, and tension-type headache was not statistically significant. A minority of patients experienced headaches for the first time within 3 months of their EVT (migraine 4, TTH 10). At interview time, 50 % of these new headaches still persisted. Our results suggest a temporary increase in headache in the first 3 months after EVT, which normalizes over time. Clinicians may use this knowledge to better inform their patients of functional outcomes after their EVT procedure.

  4. Characterization of monoclinic crystals in tablets by pattern-fitting procedure using X-ray powder diffraction data.

    Science.gov (United States)

    Yamamura, Shigeo; Momose, Yasunori

    2003-06-18

    The purpose of this study is to characterize the monoclinic crystals in tablets by using X-ray powder diffraction data and to evaluate the deformation feature of crystals during compression. The monoclinic crystals of acetaminophen and benzoic acid were used as the samples. The observed X-ray diffraction intensities were fitted to the analytic expression, and the fitting parameters, such as the lattice parameters, the peak-width parameters, the preferred orientation parameter and peak asymmetric parameter were optimized by a non-linear least-squares procedure. The Gauss and March distribution functions were used to correct the preferred orientation of crystallites in the tablet. The March function performed better in correcting the modification of diffraction intensity by preferred orientation of crystallites, suggesting that the crystallites in the tablets had fiber texture with axial orientation. Although a broadening of diffraction peaks was observed in acetaminophen tablets with an increase of compression pressure, little broadening was observed in the benzoic tablets. These results suggest that "acetaminophen is a material consolidating by fragmentation of crystalline particles and benzoic acid is a material consolidating by plastic deformation then occurred rearrangement of molecules during compression". A pattern-fitting procedure is the superior method for characterizing the crystalline drugs of monoclinic crystals in the tablets, as well as orthorhombic isoniazid and mannitol crystals reported in the previous paper.

  5. Film replacement by digital x-ray detectors - the correct procedure and equipment

    International Nuclear Information System (INIS)

    Ewert, U.; Zscherpel, U.; Bavendiek, K.

    2004-01-01

    New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film and revolutionise the radiological technique. Digital Detector Arrays (DDA: Flat Panel Detectors, Line Detectors) and Imaging Plates (Computed Radiography) allow a fast detection of radiographic images in a shorter time and with higher dynamic than film applications. Companies report about a reduction of exposure time down to 5 - 25% in comparison to NDT film exposures. This provides together with the reduction of consumables economical (and also ecological) benefits and short amortisation periods. But this does not always provide the same image quality as NDT film. The requirements of the European and USA standards for film radiography are analysed to derive correct requirements for the digital image quality and procedures for prediction and measurement of image quality. Basically the USA standards seem to be more tolerant for these new innovative technologies. New standard proposals use signal/noise ratio and unsharpness as dominant parameters for image quality. Specialised measurement procedures are described. The properties of the new detectors can be controlled by electronics and exposure conditions. New names appear in literature like 'direct radiography' and 'film replacement techniques'. The basic advantage of the new digital techniques is the possibility to use numeric procedures for image interpretation. Industrial radiology can be optimised for crack detection as well as for analysis of flaw depth and shape measurement. Automated flaw detection, measurement of part dimensions and detection of completeness are used for serial part inspection devices. Parallel to the development of DDA's, an extraordinary increase of Computed Tomography (CT) applications can be observed. (author)

  6. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  7. Post ablation recanalization of varicose veins of the limbs: Comparison ablation method of mechanochemical and laser procedure

    Science.gov (United States)

    Suhartono, R.; Irfan, W.; Wangge, G.; Moenadjat, Y.; Destanto, W. I.

    2017-08-01

    Endovenous ablation has been performed for varicose veins of the limbs in Indonesia since 2010. Endovenous laser ablation (EVLA) therapy has been performed in Cipto Mangunkusumo Hospital (RSCM) in Jakarta, and mechanochemical ablation (MOCA) has been conducted in Fatmawati Hospital. This was a descriptive analytical study, with a cross-sectional design to analyze post-ablation recanalization after MOCA and EVLA procedures. Patients who had undergone MOCA or EVLA treatment were interviewed 3-18 months after the procedures. All the patients underwent vascular ultrasonography (USG) of the operated limb to assess recanalization. Secondary presurgery data were obtained from the patients’ from patients’ medical records. The clinical characteristics of the subjects were recorded to compare the potential correlation between these characteristics and recanalization post-MOCA and EVLA procedures. All the data were analyzed using SPSS ver. 20.0. The study consisted of 43 limbs: 24 treated by MOCA and 19 treated by EVLA. Most subjects in the MOCA group were 7 mm in 13/19 extremities. In the MOCA group, total recanalization occurred in 2/24 extremities, and partial recanalization occurred in 8/24 extremities. In the EVLA group, total recanalization occurred in 1/19 extremities, and partial recanalization occurred in 3/19 extremities. The association between the clinical characteristics of the patients and recanalization was not statistically significant (p > 0.05). The recanalization tendency was higher in the MOCA group than in the EVLA group. Although there was no statistically significant association between the clinical characteristics of the patients and recanalization, the largest diameter of the VSM presurgery (>7 mm) was higher in 3/4 extremities in the MOCA group, as compared to 3/13 extremities in the EVLA group.

  8. Workflow optimisation for multimodal imaging procedures: a case of combined X-ray and MRI-guided TACE.

    Science.gov (United States)

    Fernández-Gutiérrez, Fabiola; Wolska-Krawczyk, Malgorzata; Buecker, Arno; Houston, J Graeme; Melzer, Andreas

    2017-02-01

    This study presents a framework for workflow optimisation of multimodal image-guided procedures (MIGP) based on discrete event simulation (DES). A case of a combined X-Ray and magnetic resonance image-guided transarterial chemoembolisation (TACE) is presented to illustrate the application of this method. We used a ranking and selection optimisation algorithm to measure the performance of a number of proposed alternatives to improve a current scenario. A DES model was implemented with detail data collected from 59 TACE procedures and durations of magnetic resonance imaging (MRI) diagnostic procedures usually performed in a common MRI suite. Fourteen alternatives were proposed and assessed to minimise the waiting times and improve workflow. Data analysis observed an average of 20.68 (7.68) min of waiting between angiography and MRI for TACE patients in 71.19% of the cases. Following the optimisation analysis, an alternative was identified to reduce waiting times in angiography suite up to 48.74%. The model helped to understand and detect 'bottlenecks' during multimodal TACE procedures, identifying a better alternative to the current workflow and reducing waiting times. Simulation-based workflow analysis provides a cost-effective way to face some of the challenges of introducing MIGP in clinical radiology, highligthed in this study.

  9. Effects of release procedures on the primary stress response and post-release survival and growth of hatchery-reared spotted seatrout Cynoscion nebulosus.

    Science.gov (United States)

    Guest, T W; Rakocinski, C F; Evans, A N; Blaylock, R B

    2017-03-01

    To help explain the apparent poor post-release success of hatchery-reared (HR) spotted seatrout Cynoscion nebulosus, this study examined the effects of handling, transport and release procedures on the stress response of two age classes [48 and 80 day post-hatch (dph)] of HR C. nebulosus, as measured by cortisol concentrations and the post-release survival and growth of 48 and 80 dph HR C. nebulosus. As a proxy for stress, tissue cortisol was measured at various times during the handling, tagging (80 dph), transport, acclimation and release process. To consider the implications of the pre-release stressors, growth and survival were monitored in separate field experiments for each age class of acclimated post-transport C. nebulosus using control C. nebulosus that only experienced anaesthesia, transport, acclimation and a net release v. experimental C. nebulosus that underwent the entire routine procedure, including anaesthesia, tagging, transport, acclimation and gravity release through a pipe. For 48 dph C. nebulosus, mean cortisol varied significantly throughout handling and transport, increasing more than six-fold from controls before decreasing in mean concentration just prior to release. For 80 dph C. nebulosus, cortisol varied throughout handling, tagging and transport, first increasing more than three-fold compared with control C. nebulosus, before decreasing and rising slightly just prior to release. For 48 dph C. nebulosus within field enclosures, survival was high and similar for control and experimental groups; experimental C. nebulosus, however, were shorter, lighter and lower in condition than control C. nebulosus. For 80 dph C. nebulosus within field enclosures, fewer experimental C. nebulosus survived and those that did survive were of lower condition than C. nebulosus from the control group. Small untagged C. nebulosus may survive the release procedure better than larger C. nebulosus carrying a coded-wire tag. These findings document

  10. Rendezvous cannulation technique reduces post-ERCP pancreatitis: a prospective nationwide study of 12,718 ERCP procedures.

    Science.gov (United States)

    Swahn, Fredrik; Nilsson, Magnus; Arnelo, Urban; Löhr, Matthias; Persson, Gunnar; Enochsson, Lars

    2013-04-01

    The aim of this study was to investigate if intraoperative rendezvous cannulation reduces the risk of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP) because there is no universal consensus on the optimal treatment of common bile duct stones. We performed a nationwide case-control study, nested within the cohort of ERCP procedures reported to the Swedish Registry for Gallstone Surgery and ERCP (GallRiks), between 2007 and 2009. Data were collected prospectively from a web-based registry of ERCP procedures that includes variables such as patient characteristics, indication, cannulation technique, diagnostic findings, therapeutic measures, and complications. The primary outcome was PEP. The registry included 12,718 ERCP procedures performed on patients without a history of previous ERCP. The risk of PEP when using the rendezvous technique compared with those who were cannulated by conventional means was reduced from 3.6 to 2.2% (odds ratio (OR) 0.5, 95% confidence interval 0.2-0.9, P=0.02). Although a significant reduction there are overall relatively few cases with PEP and the calculated numbers needed to treat to avoid one case of PEP is as high as 71. Other factors associated with increased risk of PEP were young age, prolonged procedure time, and elective ERCP. Rendezvous bile duct cannulation during ERCP reduces the risk of PEP from 3.6 to 2.2% compared with conventional biliary cannulation.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  13. International comparison of interpolation procedures for the efficiency of germanium gamma-ray spectrometers (GAM83 exercise)

    International Nuclear Information System (INIS)

    Zijp, W.L.; Polle, A.N.; Nolthenius, H.J.

    1986-01-01

    Results are presented for the outcome of an international intercomparison of a particular gamma-ray spectrometric procedure. Laboratories were asked to determine full energy peak efficiencies and activities by means of their own procedures, starting from supplied peak-efficiency data. Four data sets for four different conditions of germanium detectors were distributed. The sets comprised: a high accuracy- (uncertainty > 1%) data set with a relatively large number of measured data (SET 1); a low accuracy- (uncertainty 3-5%) data set with a relatively small number of measured data (SET 2); a low energy-data set (SET 3); a high accuracy-data set with a relatively small number of measured data (SET 4). The intercomparison (coded GAM83) was organized and analyzed under auspices of the International Committee for Radionuclide Metrology (ICRM). The results comprise the analysis of the contributions of 41 participants

  14. Addendum: ``Hard X-Rays and Gamma Rays from Type Ia Supernovae'' (ApJ, 492, 228 [1998])

    Science.gov (United States)

    Höflich, Peter; Wheeler, J. C.

    2004-04-01

    We report a subtle error in the normalization of the absolute flux published in our original article (hereafter HWK98), and some minor updates. The normalization problem is related to the post-processing. As a consequence, the reported line fluxes are too large at early times. Note that Figure 1 of P. Höflich (ApJ, 492, 228 [1998]) has been transferred from HWK98. Results of previous papers are not affected (E. Müller, P. Höflich, A. M. Khokhlov, & E. Müller, ApJ, 492, 228 [1998]; P. Höflich, A. M. Khokhlov, & E. Müller, ApJ, 492, 228 [1998]). For calculating the γ-ray spectra, the γ-ray transport is solved via a Monte Carlo code that produces an output file containing the Eddington flux, the energy input by radioactive decay and escape probability, ζ, of γ-ray photons. In a postprocessing step, the spectrum is renormalized and convolved with the instrumental response function of the γ-ray telescope. A two-step procedure is used to obtain the emergent spectra to separate the CPU-intensive Monte Carlo transport calculation from the ``fast'' second step, allowing us to study the influence of the instrument on the observables (e.g., E. Müller, P. Höflich, A. M. Khokhlov, & E. Müller, ApJ, 492, 228 [1998

  15. SHOULD ONE USE THE RAY-BY-RAY APPROXIMATION IN CORE-COLLAPSE SUPERNOVA SIMULATIONS?

    International Nuclear Information System (INIS)

    Skinner, M. Aaron; Burrows, Adam; Dolence, Joshua C.

    2016-01-01

    We perform the first self-consistent, time-dependent, multi-group calculations in two dimensions (2D) to address the consequences of using the ray-by-ray+ transport simplification in core-collapse supernova simulations. Such a dimensional reduction is employed by many researchers to facilitate their resource-intensive calculations. Our new code (Fornax) implements multi-D transport, and can, by zeroing out transverse flux terms, emulate the ray-by-ray+ scheme. Using the same microphysics, initial models, resolution, and code, we compare the results of simulating 12, 15, 20, and 25 M ⊙ progenitor models using these two transport methods. Our findings call into question the wisdom of the pervasive use of the ray-by-ray+ approach. Employing it leads to maximum post-bounce/pre-explosion shock radii that are almost universally larger by tens of kilometers than those derived using the more accurate scheme, typically leaving the post-bounce matter less bound and artificially more “explodable.” In fact, for our 25 M ⊙ progenitor, the ray-by-ray+ model explodes, while the corresponding multi-D transport model does not. Therefore, in two dimensions, the combination of ray-by-ray+ with the axial sloshing hydrodynamics that is a feature of 2D supernova dynamics can result in quantitatively, and perhaps qualitatively, incorrect results.

  16. Hysterosalpingo-foam sonography (HyFoSy): Tolerability, safety and the occurrence of pregnancy post-procedure.

    Science.gov (United States)

    Tanaka, Keisuke; Chua, Jackie; Cincotta, Robert; Ballard, Emma L; Duncombe, Gregory

    2018-02-01

    Fallopian tube patency testing is an essential part of infertility evaluation. Hysterosalpingo-contrast sonography (HyCoSy) has been described as reliable, well tolerated and safe compared to other modalities such as laparoscopy and a dye test or hysterosalpingography. Limited availability of the previously used contrast has led to the introduction of a foam contrast agent as an alternative. To assess the tolerability, safety and occurrence of pregnancy post-procedure of hysterosalpingo-foam sonography (HyFoSy). A retrospective cohort study of women who had a HyFoSy at Queensland Ultrasound for Women from March 2013 to February 2015. A questionnaire was sent to their referring doctor to identify any complications or subsequent pregnancies with or without artificial reproductive technology (ART) within six months of the HyFoSy. Of 200 women, four cases were abandoned due to difficulty introducing the intracervical catheter, severe discomfort or a vasovagal episode. Response from referring doctors for 155 women reported no post-procedural complication. One hundred and eleven women were followed up for at least six months. Twenty-four out of 59 women (40.7%) who had ART and 24 out of 52 women (46.2%) who did not have ART conceived. Fifty percent of women who were nulligravida at the time of investigation, found to have at least one patent fallopian tube, whose partner had a normal semen analysis, spontaneously conceived within the time of follow up. HyFoSy is well tolerated and safe. A preponderance of pregnancies in the first month after HyFoSy suggests that a therapeutic effect may exist. © 2017 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  17. The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial.

    Science.gov (United States)

    Suwannasom, Pannipa; Sotomi, Yohei; Ishibashi, Yuki; Cavalcante, Rafael; Albuquerque, Felipe N; Macaya, Carlos; Ormiston, John A; Hill, Jonathan; Lang, Irene M; Egred, Mohaned; Fajadet, Jean; Lesiak, Maciej; Tijssen, Jan G; Wykrzykowska, Joanna J; de Winter, Robbert J; Chevalier, Bernard; Serruys, Patrick W; Onuma, Yoshinobu

    2016-06-27

    The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up. Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent. The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre- and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected. Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p 0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037). BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared to metallic EES. Post-procedural devices asymmetry were independently associated with DoCE following percutaneous coronary intervention. However, this approach should be viewed as hypothesis generating due to low event rates. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281). Copyright © 2016 American

  18. NaI(Tl) scintillator detectors stripping procedure for air kerma measurements of diagnostic X-ray beams

    Science.gov (United States)

    Oliveira, L. S. R.; Conti, C. C.; Amorim, A. S.; Balthar, M. C. V.

    2013-03-01

    Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector's materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.

  19. NaI(Tl) scintillator detectors stripping procedure for air kerma measurements of diagnostic X-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, L.S.R. [Centro Tecnológico do Exército, CTEx (Brazilian Army Technological Center), Av. das Américas n° 28705, 23085-470 Rio de Janeiro (Brazil); Instituto de Radioprotecão e Dosimetria, CNEN/IRD (Institute for Radioprotection and Dosimetry, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22783-127 Barra da Tijuca, Rio de Janeiro (Brazil); Conti, C.C., E-mail: ccconti@ird.gov.br [Instituto de Radioprotecão e Dosimetria, CNEN/IRD (Institute for Radioprotection and Dosimetry, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22783-127 Barra da Tijuca, Rio de Janeiro (Brazil); Amorim, A.S.; Balthar, M.C.V. [Centro Tecnológico do Exército, CTEx (Brazilian Army Technological Center), Av. das Américas n° 28705, 23085-470 Rio de Janeiro (Brazil)

    2013-03-21

    Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector’s materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.

  20. Uterine Fibroid Embolization Can Still Be Improved: Observations on Post-Procedure Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Dorenberg, E.J.; Novakovic, Z.; Smith, H.J.; Hafsahl, G.; Jakobsen, J.Aa.

    2005-01-01

    PURPOSE: To evaluate the efficacy and completeness of uterine fibroid embolization (UFE) measured by changes in volume and signal intensity at magnetic resonance imaging (MRI), and to compare with clinical outcome. MATERIAL AND METHODS: 40 women with symptomatic uterine fibroids underwent bilateral uterine artery embolization. At MRI studies, including post-contrast sequences before and repeatedly after treatment, the uterus and dominant fibroids were evaluated for volume, location, and contrast enhancement. Prior to treatment, all myomas showed significant contrast enhancement. The mean uterine volume was 929 ml. Clinical examinations with emphasis on menorrhagia, pelvic pain, and urinary dysfunction were performed before and 6 and 12 months after treatment. RESULTS: UFE was bilaterally successful in 38 patients. After UFE, MRI showed no enhancement of myomas in 30 patients. In 8 patients, post-procedural MRI revealed partially remaining vascularization of fibroids despite angiographically complete embolization of the uterine arteries. On average, uterine volume decreased by 46.2% at 12 months. There was significant improvement of symptoms in the majority of patients, but slightly less improvement in patients with partially remaining vascularization of myomas. CONCLUSION: UFE causes significant volume reduction of myomas and clinical improvement. MRI can reveal remaining vascularization in myomas despite angiographically complete embolization of uterine arteries

  1. SHOULD ONE USE THE RAY-BY-RAY APPROXIMATION IN CORE-COLLAPSE SUPERNOVA SIMULATIONS?

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, M. Aaron; Burrows, Adam [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Dolence, Joshua C., E-mail: burrows@astro.princeton.edu, E-mail: askinner@astro.princeton.edu, E-mail: jdolence@lanl.gov [CCS-2, Los Alamos National Laboratory, P.O. Box 1663 Los Alamos, NM 87545 (United States)

    2016-11-01

    We perform the first self-consistent, time-dependent, multi-group calculations in two dimensions (2D) to address the consequences of using the ray-by-ray+ transport simplification in core-collapse supernova simulations. Such a dimensional reduction is employed by many researchers to facilitate their resource-intensive calculations. Our new code (Fornax) implements multi-D transport, and can, by zeroing out transverse flux terms, emulate the ray-by-ray+ scheme. Using the same microphysics, initial models, resolution, and code, we compare the results of simulating 12, 15, 20, and 25 M {sub ⊙} progenitor models using these two transport methods. Our findings call into question the wisdom of the pervasive use of the ray-by-ray+ approach. Employing it leads to maximum post-bounce/pre-explosion shock radii that are almost universally larger by tens of kilometers than those derived using the more accurate scheme, typically leaving the post-bounce matter less bound and artificially more “explodable.” In fact, for our 25 M {sub ⊙} progenitor, the ray-by-ray+ model explodes, while the corresponding multi-D transport model does not. Therefore, in two dimensions, the combination of ray-by-ray+ with the axial sloshing hydrodynamics that is a feature of 2D supernova dynamics can result in quantitatively, and perhaps qualitatively, incorrect results.

  2. Submicron beam X-ray diffraction of nanoheteroepitaxily grown GaN: Experimental challenges and calibration procedures

    Energy Technology Data Exchange (ETDEWEB)

    Bonanno, P.L., E-mail: PeterBonanno@gatech.ed [Georgia Institute of Technology/GTL, UMI 2958 Georgia Tech-CNRS, 57070 Metz (France); Gautier, S. [Laboratoire Materiaux Optiques, Photonique et Micro-Nano Systemes, UMR CNRS 7132, Universite de Metz et SUPELEC, 2 rue E. Belin, 57070 Metz (France); Sirenko, A.A. [Department of Physics, New Jersey Institute of Technology, Newark, NJ 07102 (United States); Kazimirov, A. [Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, New York 14853 (United States); Cai, Z.-H. [Advanced Photon Source, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Goh, W.H. [Georgia Institute of Technology/GTL, UMI 2958 Georgia Tech-CNRS, 57070 Metz (France); Martin, J. [Laboratoire Materiaux Optiques, Photonique et Micro-Nano Systemes, UMR CNRS 7132, Universite de Metz et SUPELEC, 2 rue E. Belin, 57070 Metz (France); Martinez, A. [Laboratoire de Photonique et de Nanostructures, UPR CNRS 20, Route de Nozay, 91460 Marcoussis (France); Moudakir, T. [Laboratoire Materiaux Optiques, Photonique et Micro-Nano Systemes, UMR CNRS 7132, Universite de Metz et SUPELEC, 2 rue E. Belin, 57070 Metz (France); Maloufi, N. [Laboratoire d' Etude des Textures et Application aux Materiaux, UMR CNRS 7078, Ile du Saulcy, 57045 Metz Cedex 1 (France); Assouar, M.B. [Laboratoire de Physique des Milieux Ionises et Applications, Nancy University, CNRS, BP 239, F-54506 Vandoeuvre-les-Nancy Cedex (France); Ramdane, A.; Gratiet, L. Le [Laboratoire de Photonique et de Nanostructures, UPR CNRS 20, Route de Nozay, 91460 Marcoussis (France); Ougazzaden, A. [Georgia Institute of Technology/GTL, UMI 2958 Georgia Tech-CNRS, 57070 Metz (France)

    2010-02-15

    Highly relaxed GaN nanodots and submicron ridges have been selectively grown in the NSAG regime using MOVPE on lattice mismatched 6H-SiC and AlN substrates. 2D real space and 3D reciprocal space mapping was performed with a CCD detector using 10.4 keV synchrotron X-ray radiation at the 2-ID-D micro-diffraction beamline at Advanced Photon Source (APS). Calibration procedures have been developed to overcome the unique challenges of analyzing NSAG structures grown on highly mismatched substrates. We studied crystallographic planar bending on the submicron scale and found its correlation with strain relaxation in the NSAG ridges.

  3. Stridor Post-Pneumonectomy - “The Post-pneumonectomy Syndrome”

    Directory of Open Access Journals (Sweden)

    Manoj Waghmare

    2017-04-01

    Full Text Available We report a case of a 33 year old lady who presented to our department with complaints of breathlessness and stridor. On enquiry she gave history of right pneumonectomy for right main bronchus carcinoid 15 years ago. Chest X-ray as initial investigation showed homogenous opacity in right hemothorax with mediastinal shift to right. Computed tomography of thorax showed post-pneumonectomy status with left lower lobe bronchus compression between the aorta and main pulmonary artery with post obstructive overinflation of left lower lobe. Spirometry was suggestive of an obstructive abnormality. Diagnosis of post-pneumonectomy syndrome was made and patient was treated with inhaled corticosteroids and inhaled long acting beta2 agonist.

  4. Gamma-ray irradiation and post-irradiation at room and elevated temperature response of pMOS dosimeters with thick gate oxides

    Directory of Open Access Journals (Sweden)

    Pejović Momčilo M.

    2011-01-01

    Full Text Available Gamma-ray irradiation and post-irradiation response at room and elevated temperature have been studied for radiation sensitive pMOS transistors with gate oxide thickness of 100 and 400 nm, respectively. Their response was followed based on the changes in the threshold voltage shift which was estimated on the basis of transfer characteristics in saturation. The presence of radiation-induced fixed oxide traps and switching traps - which lead to a change in the threshold voltage - was estimated from the sub-threshold I-V curves, using the midgap technique. It was shown that fixed oxide traps have a dominant influence on the change in the threshold voltage shift during gamma-ray irradiation and annealing.

  5. Post procedural complications of cardiac implants done in a resource limited setting under 'C' arm: A single centre experience.

    Science.gov (United States)

    Jayachandra, A; Aggarwal, Vivek; Kumar, Sandeep; Nagesh, I V

    2018-04-01

    Cardiology interventions in peripheral hospitals is a challenging task where cardiologist have to fight against time and limited resources. Most of the sudden cardiac deaths occur due to arrhythmia and heart blocks/sinus node dysfunction. Our study is a single peripheral center experience of cardiac devices implantation using a 'C' Arm. The aim of this study was to post procedural complications of cardiac implants done in aresource limited setting under 'C' arm. This study is done at a peripheral cardiology center with no cardiac catheterization laboratory (CCL) facilities. Consecutive patients reporting to cardiology center, between Jan 2015 and Oct 2016, with a definite indication for cardiac device implant were included in the study. All the procedure of implantation was done in the operation theatre under 'C' arm under local anesthesia with continuous cardiac monitoring and critical care back up. Total 58 device implantations were done from Jan 2015 to Oct 2016. The mean age of the patients was 67.15 ± 10.85 years. Males constituted almost two third (68.9%) of patients. The commonest indication for device implantation was sinus node dysfunction in 60.34% followed by complete heart block in 25.86% and ventricular tachycardia in 12.06%. No post procedure infection was observed in our study. Device implantation constitute a major group of life saving interventions in cardiology practice. Our study has emphasised that when appropriate aseptic measures are taken during device implantation at peripheral centres, the complications rate are comparable to interventions done at advance cardiac centres.

  6. Assessing the registration of CT-scan data to intraoperative x rays by fusing x rays and preoperative information

    Science.gov (United States)

    Gueziec, Andre P.

    1999-05-01

    This paper addresses a key issue of providing clinicians with visual feedback to validate a computer-generated registration of pre-operative and intra-operative data. With this feedback information, the clinician may decide to proceed with a computer-assisted intervention, revert to a manual intervention, or potentially provide information to the computer system to improve the registration. The paper focuses on total hip replacement (THR) surgery, but similar techniques could be applied to other types of interventions or therapy, including orthopedics, neurosurgery, and radiation therapy. Pre-operative CT data is used to plane the surgery (select an implant type, size and precise position), and is registered to intra-operative X-ray images, allowing to execute the plan: mill a cavity with the implant's shape. (Intra-operative X-ray images must be calibrated with respect to the surgical device executing the plan). One novel technique presented in this paper consists of simulating a post-operative X-ray image of the tissue of interest before doing the procedure, by projecting the registered implant onto an intra-operative X- ray image (corrected for distortion or not), providing clinicians with familiar and easy to interpret images. As an additional benefit, this method provides new means for comparing various strategies for registering pre-operative data to the physical space of the operating room.

  7. Interactive Stable Ray Tracing

    DEFF Research Database (Denmark)

    Dal Corso, Alessandro; Salvi, Marco; Kolb, Craig

    2017-01-01

    Interactive ray tracing applications running on commodity hardware can suffer from objectionable temporal artifacts due to a low sample count. We introduce stable ray tracing, a technique that improves temporal stability without the over-blurring and ghosting artifacts typical of temporal post-pr...

  8. Fundamental quantification procedure for total reflection X-ray fluorescence spectra analysis and elements determination

    International Nuclear Information System (INIS)

    Wegrzynek, D.; Holynska, B.

    1997-01-01

    A method for the determination of the concentrations of elements in particulate-like samples measured in total reflection geometry is proposed. In the proposed method the fundamental parameters are utilized for calculating the sensitivities of elements and an internal standard is used to account for the unknown mass per unit area of a sample and geometrical constant of the spectrometer. The modification of the primary excitation spectrum on its way to a sample has been taken into consideration. The concentrations of the elements to be determined are calculated simultaneously with the spectra deconvolution procedure. In the process of quantitative analysis the intensities of all X-ray peaks corresponding to K and L-series lines present in the analyzed spectrum are taken into account. (Author)

  9. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... Emitting Products and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin it ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most x- ...

  10. Los Alamos Scientific Laboratory x-ray survey manual

    International Nuclear Information System (INIS)

    Olsher, R.H.

    1980-02-01

    A manual has been developed by the Health Physics Group to establish procedures for routine testing of industrial and analytical x-ray equipment for compliance with applicable LASL administrative requirements and technical bulletins. Radiation protection survey procedures were developed for the following types of equipment: x-ray diffraction and fluorescence analysis systems, industrial cabinet x-ray systems, industrial noncabinet x-ray systems, and electron microscopes

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... The x-ray tube is connected to a flexible arm that is extended over the patient while an x-ray film holder or image recording plate is placed beneath the patient. top of page How does the procedure work? X-rays are a form of radiation like ...

  12. Evaluation of ammonium bifluoride fusion for rapid dissolution in post-detonation nuclear forensic analysis

    International Nuclear Information System (INIS)

    Hubley, Nicholas T.; Brockman, John D.; Robertson, J. David; Missouri Univ., Columbia, MO

    2017-01-01

    Dissolution of geological reference materials by fusion with ammonium bifluoride, NH_4HF_2 or ABF, was evaluated for its potential use in post-detonation nuclear forensics. The fusion procedure was optimized such that the total dissolution time was <3 h without compromising recovery. Geological reference materials containing various levels of silicates were dissolved and measured by ICP-MS to quantify elemental recovery. Dissolutions of NIST 278 obsidian and urban canyon matrix were performed with radiotracer spikes to measure potential loss of volatile elements during the fusion procedure via gamma-ray spectroscopy. Elemental percent recoveries obtained by ICP-MS were found to be 80-120% while recoveries of radiotracers were observed to be 90-100% with the exception of iodine.

  13. Evaluation of ammonium bifluoride fusion for rapid dissolution in post-detonation nuclear forensic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hubley, Nicholas T. [Missouri Univ., Columbia, MO (United States). Dept. of Chemistry; Brockman, John D. [Missouri Univ., Columbia, MO (United States). Research Reactor Center; Robertson, J. David [Missouri Univ., Columbia, MO (United States). Research Reactor Center; Missouri Univ., Columbia, MO (United States). Dept. of Chemistry

    2017-10-01

    Dissolution of geological reference materials by fusion with ammonium bifluoride, NH{sub 4}HF{sub 2} or ABF, was evaluated for its potential use in post-detonation nuclear forensics. The fusion procedure was optimized such that the total dissolution time was <3 h without compromising recovery. Geological reference materials containing various levels of silicates were dissolved and measured by ICP-MS to quantify elemental recovery. Dissolutions of NIST 278 obsidian and urban canyon matrix were performed with radiotracer spikes to measure potential loss of volatile elements during the fusion procedure via gamma-ray spectroscopy. Elemental percent recoveries obtained by ICP-MS were found to be 80-120% while recoveries of radiotracers were observed to be 90-100% with the exception of iodine.

  14. Procedural discourse performance in adults with severe traumatic brain injury at 3 and 6 months post injury.

    Science.gov (United States)

    Stubbs, Elin; Togher, Leanne; Kenny, Belinda; Fromm, Davida; Forbes, Margaret; MacWhinney, Brian; McDonald, Skye; Tate, Robyn; Turkstra, Lyn; Power, Emma

    2018-01-01

    There is limited research on communicative recovery during the early stages after a severe traumatic brain injury (TBI) in adults. In the current study 43 people with severe TBI described a simple procedure at 3 and 6 months post injury and this was compared to the description provided by 37 healthy speakers. Linguistic productivity and the presence of macrostructural discourse elements were analysed. No change occurred in productivity in the TBI group between the two time points. There was increased use of relevant information (macrostructure) over time for the TBI group, reflecting improvement. People with TBI differed from controls in speech rate and in two out of three macrostructural categories at both time points, indicating difficulties even after 12 weeks of recovery. Overall, the quality, rather than the quantity of discourse was disordered for participants with TBI. Findings indicate that procedural discourse is sensitive to discourse deficits of people with TBI and can be used to map recovery during the sub-acute phase.

  15. GRAP, Gamma-Ray Level-Scheme Assignment

    International Nuclear Information System (INIS)

    Franklyn, C.B.

    2002-01-01

    1 - Description of program or function: An interactive program for allocating gamma-rays to an energy level scheme. Procedure allows for searching for new candidate levels of the form: 1) L1 + G(A) + G(B) = L2; 2) G(A) + G(B) = G(C); 3) G(A) + G(B) = C (C is a user defined number); 4) L1 + G(A) + G(B) + G(C) = L2. Procedure indicates intensity balance of feed and decay of each energy level. Provides for optimization of a level energy (and associated error). Overall procedure allows for pre-defining of certain gamma-rays as belonging to particular regions of the level scheme, for example, high energy transition levels, or due to beta- decay. 2 - Method of solution: Search for cases in which the energy difference between two energy levels is equal to a gamma-ray energy within user-defined limits. 3 - Restrictions on the complexity of the problem: Maximum number of gamma-rays: 999; Maximum gamma ray energy: 32000 units; Minimum gamma ray energy: 10 units; Maximum gamma-ray intensity: 32000 units; Minimum gamma-ray intensity: 0.001 units; Maximum number of levels: 255; Maximum level energy: 32000 units; Minimum level energy: 10 units; Maximum error on energy, intensity: 32 units; Minimum error on energy, intensity: 0.001 units; Maximum number of combinations: 6400 (ca); Maximum number of gamma-ray types : 127

  16. Distraction arthroplasty compared to other cartilage preservation procedures in patients with post-traumatic arthritis: a systematic review.

    Science.gov (United States)

    Rivera, Jessica C; Beachler, Jason A

    2018-01-23

    Post-traumatic arthritis (PTA) is characterized by the deterioration of articular cartilage temporally associated with an articular injury. With a paucity of literature comparing joint preservation techniques, we performed a systematic review of the literature intending to describe and summarize the results of ankle distraction arthroplasty as it compares with studies on tibio-talar microfracture, allograft, and autograft for ankle joint preservation in the post-traumatic population under 50 years of age. Research databases were searched and abstracts screened for relevance on our topic of interest. Abstracts meeting screening criteria with high interobserver reliability underwent full-manuscript review and coding for pertinent citation, study level, treatment, and outcome variables. Outcome variables for patient-reported pain scales, validated outcome measurement tools, radiographic progression, reoperation/re-treatment rates, and complication rates were recorded. Out of 105 unique citations, 10 publications were included. The distraction arthroplasty studies had 36 out of 181 patients requiring reoperation for complications (19.9%), while other joint-preserving procedures studies had 40 out of 177 patients requiring reoperations for complications (22.6%). Clinical outcome scores at mean follow-up time ranging from 2 to 10 years between studies were similar. Reported results for a variety of cartilage preservation procedures, including distraction arthroplasty, are satisfactory and reoperation rates for complication are similar. Limitations in available data and underlying study quality affect synthesis of the results therein. While distraction arthroplasty is an option for cartilage preservation in patients with PTA of the ankle, the technique is highly specialized which may affect the external validity. III.

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  19. Reduction of doses from diagnostic X-ray procedures

    International Nuclear Information System (INIS)

    Gudden, F.; Kuhn, H.

    1992-01-01

    More recent developments in the field of receiver systems for X-rays have made it possible for doses required in X-ray examinations to be gradually reduced to no more than 5% of the radiation patients were exposed to 30 years ago. Despite this fact, the image quality standards necessary to establish even considerably improved. The author suggests to repeat series of measurements carried out in the distant past to be able to make a population-based assessment of the current risk from the effective equivalence dose in one year. In all likelihood, such a survey would prove the quivalence dose to be much lower than the degree of environmental radiation exposure. (orig./DGD) [de

  20. Method and apparatus for examining a body by means of penetrating radiation such as x-rays

    International Nuclear Information System (INIS)

    Barnea, D.I.

    1984-01-01

    An image-reconstructive technique for examining a body by means of penetrating radiation, such as X-rays, is described. A pre-body collimator having a two-dimensional array of radiation-transmitting holes each bordered by radiation non-transmitting walls is disposed between the body and the source of radiation, and a plurality of exposures are made onto a radiation-sensitive surface, in which the radiation is projected through the collimator while the radiation source is at a plurality of different locations, such that during the successive exposures, the radiation from the source passes through different ray paths defined by the holes in the pre-body collimator. The radiation level received by each of the radiation-sensitive surface elements is detected, stored, and processed to reconstruct the two-dimensional radiation pattern but with enhanced resolution. Preferably a post-body collimator is also used to suppress scattering. Described are a four-exposure procedure and a nine-exposure procedure

  1. Management of Post-Traumatic Phlegmasia Cerulea Dolens via Right-to-Left Femoral Vein to Femoral Vein Bypass (Palma Procedure).

    Science.gov (United States)

    Dua, Anahita; Heller, Jennifer; Lee, Cheong

    2017-11-01

    Phlegmasia cerulea dolens (PCD) is a rare condition resulting from venous occlusion that impairs arterial flow. We report a rare case of post-traumatic PCD after ligation of the iliac vein with successful treatment by right-to-left femoral vein to femoral vein bypass using left great saphenous vein (Palma procedure). The clinical presentation, diagnostic process, and approach to management along with a literature review on the operative management of PCD are presented in this case report.

  2. Technical Aspect on Procedure of Gamma-Ray Pipeline Inspection

    International Nuclear Information System (INIS)

    Rasif Mohd Zain; Ainul Mardhiah Terry; Norman Shah Dahing

    2015-01-01

    The main problems happen in industrial pipelines are deposit build-up, blockage, corrosion and erosion. These effects will give a constraint in transporting refined products to process or production points and cause a major problem in production. One of the techniques to inspect the problem is using gamma-ray pipe scans. The principle of the technique is gamma-ray absorption technique. In this paper describes on the technical aspect to perform the pipe inspection in laboratory work. (author)

  3. Preparation of biological samples for transmission X-ray microanalysis: a review of alternative procedures to the use of sectioned material

    International Nuclear Information System (INIS)

    Sigee, D.C.

    1988-01-01

    Although transmission X-ray microanalysis of biological material has traditionally been carried out mainly on sectioned preparations, a number of alternative procedures exist. These are considered under three major headings - whole cell preparations, analysis of cell homogenates and biological fluids, and applications of the technique to microsamples of purified biochemicals. These three aspects provide a continuous range of investigative level - from the cellular to the molecular. The use of X-ray microanalysis with whole cell preparations is considered in reference to eukaryote (animal) cells and prokaryotes - where it has particular potential in environmental studies on bacteria. In the case of cell homogenates and biological fluids, the technique has been used mainly with microdroplets of animal material. The use of X-ray microanalysis with purified biochemicals is considered in relation to both particulate and non-particulate samples. In the latter category, the application of this technique for analysis of thin films of metalloprotein is particularly emphasised. It is concluded that wider use could be made of the range of preparative techniques available - both within a particular investigation, and in diverse fields of study. Transmission X-ray microanalysis has implications for environmental, physiological and molecular biology as well as cell biology

  4. Mapping the continuous reciprocal space intensity distribution of X-ray serial crystallography.

    Science.gov (United States)

    Yefanov, Oleksandr; Gati, Cornelius; Bourenkov, Gleb; Kirian, Richard A; White, Thomas A; Spence, John C H; Chapman, Henry N; Barty, Anton

    2014-07-17

    Serial crystallography using X-ray free-electron lasers enables the collection of tens of thousands of measurements from an equal number of individual crystals, each of which can be smaller than 1 µm in size. This manuscript describes an alternative way of handling diffraction data recorded by serial femtosecond crystallography, by mapping the diffracted intensities into three-dimensional reciprocal space rather than integrating each image in two dimensions as in the classical approach. We call this procedure 'three-dimensional merging'. This procedure retains information about asymmetry in Bragg peaks and diffracted intensities between Bragg spots. This intensity distribution can be used to extract reflection intensities for structure determination and opens up novel avenues for post-refinement, while observed intensity between Bragg peaks and peak asymmetry are of potential use in novel direct phasing strategies.

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... procedure varies. See the Safety page for more information about radiation dose. Women should always inform their ...

  6. Determination of existing exposure level of population during X ray investigations

    International Nuclear Information System (INIS)

    Tselinov, N.V.; Kudritskij, Yu.K.

    1978-01-01

    The distribution of X ray procedures among 500 inhabitants of the city of Vorkuta in 1975 is studied. Data on the distribution of the subjects by age group and type of X ray procedure are presented. The results obtained broaden the existing concepts on hygienic importance of radiation received by the population of the country during X ray studies. It is proposed that these results be used in developing methods for standardizing X ray procedures

  7. X-Ray Study of Variable Gamma-Ray Pulsar PSR J2021+4026

    Science.gov (United States)

    Wang, H. H.; Takata, J.; Hu, C.-P.; Lin, L. C. C.; Zhao, J.

    2018-04-01

    PSR J2021+4026 showed a sudden decrease in the gamma-ray emission at the glitch that occurred around 2011 October 16, and a relaxation of the flux to the pre-glitch state at around 2014 December. We report X-ray analysis results of the data observed by XMM-Newton on 2015 December 20 in the post-relaxation state. To examine any change in the X-ray emission, we compare the properties of the pulse profiles and spectra at the low gamma-ray flux state and at the post-relaxation state. The phase-averaged spectra for both states can be well described by a power-law component plus a blackbody component. The former is dominated by unpulsed emission and probably originated from the pulsar wind nebula as reported by Hui et al. The emission property of the blackbody component is consistent with the emission from the polar cap heated by the back-flow bombardment of the high-energy electrons or positrons that were accelerated in the magnetosphere. We found no significant change in the X-ray emission properties between two states. We suggest that the change of the X-ray luminosity is at an order of ∼4%, which is difficult to measure with the current observations. We model the observed X-ray light curve with the heated polar cap emission, and we speculate that the observed large pulsed fraction is owing to asymmetric magnetospheric structure.

  8. γ-ray induced chromosome aberration in rabbit peripheral blood lymphocytes irradiated in partial and whole body and decline of aberration rate with time post-exposure

    International Nuclear Information System (INIS)

    Zhang Lianzhen; Deng Zhicheng; Wang Haiyan

    1997-01-01

    Te author presents the results of study on 60 Co γ-ray induced chromosome aberration in rabbits peripheral blood lymphocytes irradiated in partial and whole body and the aberration rate decrease with the time of post-exposure. The experiments included 5 groups, it was whole-body exposure group, partial-body exposure (abdomen and pelvic cavity) group, blood irradiation group in vitro and control group respectively. Radiation dose was 3.0 Gy delivered at rate of 0.5 Gy/min. The results show that it was no significant differences between whole body and in blood irradiation group. The chromosome aberration yield in whole body exposure group was higher than that in partial-body group and in the abdomen exposure group was higher than in that in the pelvic cavity irradiation; The chromosome aberration rate decreased with the time of post-exposure in partial and whole body by γ-ray irradiation

  9. A Review of Post and Core Application with Emphasize on Non Metallic Posts

    Directory of Open Access Journals (Sweden)

    Shahroodi MH

    2001-05-01

    Full Text Available Many different methods are suggested to restore endodontically treated teeth. Prefabricated posts can not be indicated for all teeth and cast posts require extra time and cost. In addition, with the introduction of full ceramic restorations, achieving the ideal esthetic with metal post underneath them may be problematic or impossible because the darkness of the metallic posts may show through the highly translucent all ceramic restorations. In this article the review of litature and describiton of applied methods of different procedure in restoring the root canal therapied teeth and few techniques of non metallic posts fabrication such as fiber reinforced composite and zirconium oxide posts have been described.

  10. Post procedure headache in patients treated for neurovascular arteriovenous malformations and aneurysms using endovascular therapy

    DEFF Research Database (Denmark)

    Khan, Sabrina; Amin, Faisal Mohammad; Hauerberg, John

    2016-01-01

    BACKGROUND: Though endovascular therapy (EVT) is increasingly applied in the treatment of intracranial vascular lesions, little is known about the effect of EVT on post-procedure headache. We aimed to investigate the prevalence of headache in patients who have undergone EVT for cerebral...... arteriovenous malformations (AVMs) and aneurysms. METHODS: A total of 324 patients underwent EVT treatment for aneurysms and AVMs at the Danish National Hospital from January 2012 to December 2014. We applied strict exclusion criteria in order to minimize the effect of other factors on headache occurrence, e.......g., craniotomy. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire. Headaches were classified according to ICHD-III beta criteria. RESULTS: The 59 patients underwent treatment of aneurysms (n = 43), cranial dural fistulas (n = 11), and AVMs (n = 5...

  11. Modern X-ray difraction. X-ray diffractometry for material scientists, physicists, and chemicists

    International Nuclear Information System (INIS)

    Spiess, L.; Schwarzer, R.; Behnken, H.; Teichert, G.

    2005-01-01

    The book yields a comprehensive survey over the applications of X-ray diffraction in fields like material techniques, metallurgy, electrotechniques, machine engineering, as well as micro- and nanotechniques. The necessary fundamental knowledge on X-ray diffraction are mediated foundedly and illustratively. Thereby new techniques and evaluation procedures are presented as well as well known methods. The content: Production and properties of X radiation, diffraction of X radiation, hardware for X-ray diffraction, methods of X-ray diffraction, lattice-constant determination, phase analysis, X-ray profile analysis, crystal structure analysis, X-ray radiographic stress analysis, X-ray radiographic texture analysis, crystal orientation determination, pecularities at thin films, small angle scattering

  12. Legal directives in the X-ray regulation for the field of X-ray diagnostics

    International Nuclear Information System (INIS)

    Huhn, Walter

    2012-01-01

    The operation of each X-ray device is subject to the requirements of the X-ray regulations (RoeV); for different operational modes or applications like curative diagnostics, X-ray serial examinations, X-ray radiotherapy and teleradiology different directives exist and have to be respected. The report discusses the issues licensing and notification procedures, radiation protection representative, requirements for the commissioning (teleradiology, serial X.ray examinations), technical qualification and radiation protection knowledge of physicians, technical qualification of the assistant personnel.

  13. Incidence of postoperative implant-related bacterial endocarditis in dogs that underwent trans-catheter embolization of a patent ductus arteriosus without intra- and post-procedural prophylactic antibiotics.

    Science.gov (United States)

    Szatmári, Viktor

    2017-08-01

    Intra- and post-procedural prophylactic antibiotics are routinely administered by veterinary cardiologists to dogs that undergo trans-catheter embolization of a patent ductus arteriosus for prevention of implant-related infective endocarditis. The hypothesis of our study was that primary antibiotic prophylaxis is not necessary to prevent bacterial endocarditis. In this retrospective case series 54 client-owned dogs that underwent trans-catheter occlusion of a patent ductus arteriosus in a single tertiary veterinary referral center between 2004 and 2016 were evaluated. Follow-up information was gained by telephone interviews with the owners or the referring veterinarians, or from the digital archives of the authors' clinic. Inclusion criteria were that at least one metal implant (a coil or an Amplatz duct occluder) had to be delivered in the ductal ampulla, no local or systemic antibiotics were given on the day of the intervention or the week thereafter, at least 3 months of postoperative follow-up information was available, and the author was performing the procedure either as the primary or as the supervising cardiology specialist. None of the 54 dogs developed infective endocarditis in the postoperative 3 months. A study describing a similar population reports 2 of the included 47 dogs having developed infective endocarditis in the postoperative period despite the administration of intra- and post-procedural prophylactic antibiotics. We conclude that intra- and post-procedural antibiotic prophylaxis is not justified in dogs that undergo trans-catheter closure of a patent ductus arteriosus. Proper surgical technique and the use of new sterile catheters and implants are sufficient to prevent infective endocarditis in these dogs. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Exposure of Medical Staff during Interventional Procedures

    International Nuclear Information System (INIS)

    Osvay, M.; Turak, O.

    2013-01-01

    The medical staff during interventional procedures receives significant doses on their hands, or parts of their body not covered with protective shielding equipment, as they are close to X-rays field. It can be stated, that interventional radiology and cardiology have one of the highest doses among the X-ray diagnostic procedures. The radiologist use X-ray machine directly in the interventional procedures. The occupational dose is measured only by one Kodak film badge worn under the lead apron for the estimation of the effective dose in Hungary. Our lecture presents the results of dose measurements on eye lens, hands, knees using LiF thermoluminescent dosemeters on the medical staff of two Hungarian hospitals. Results suggest that wearing only one film badge (or other dosemeter system) under the lead apron does not provide proper information on the real occupational dose of medical staff.(author)

  15. Patients exposure assessment for radiographic procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Stankovic, K.; Lazarevic, Dj.; Ciraj-Bjelac, O.)

    2007-01-01

    In this work the results of dose assessment for the most frequent radiographic procedures in diagnostic radiology are shown. Entrance surface doses were assessed for 7 radiographic procedures. Three hospitals, six x-ray units in total, were enrolled in investigation. Patient doses were estimated based on results of x-ray tube output measurements. Finally, doses were compared with Diagnostic reference level. Higher dose values were observed for chest examinations. In comparison with results from other countries, doses from this procedure in Serbia are significantly higher. Estimated doses for other procedures were well below Diagnostic reference levels [sr

  16. Procedure-specific pain management and outcome strategies

    DEFF Research Database (Denmark)

    Joshi, Girish P; Schug, Stephan A; Kehlet, Henrik

    2014-01-01

    Optimal dynamic pain relief is a prerequisite for optimizing post-operative recovery and reducing morbidity and convalescence. Procedure-specific pain management initiative aims to overcome the limitations of conventional guidelines and provide health-care professionals with practical recommendat......, optimizing fluid therapy and optimizing post-operative nursing care with early mobilization and oral feeding are utilized....... recommendations formulated in a way that facilitates clinical decision making across all the stages of the perioperative period. The procedure-specific evidence is supplemented with data from other similar surgical procedures and clinical practices to balance benefits and risks of each analgesic technique...

  17. TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Fetterly, K; Schueler, B; Grams, M [Mayo Clinic, Rochester, MN (United States); Sturchio, G [Mayo Clinic, Jacksonville, FL (United States)

    2016-06-15

    Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Direct exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.

  18. 32 CFR 162.6 - Procedures.

    Science.gov (United States)

    2010-07-01

    ... Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DEFENSE CONTRACTING PRODUCTIVITY ENHANCING CAPITAL INVESTMENT (PECI) § 162.6 Procedures. The following procedures shall be followed by the DoD Components in the... documentation, pre-investment analysis, financing, and post-investment accountability of PECI projects, when DoD...

  19. 5 CFR 1304.4605 - Post-employment restrictions.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Post-employment restrictions. 1304.4605 Section 1304.4605 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET ADMINISTRATIVE PROCEDURES POST EMPLOYMENT CONFLICT OF INTEREST § 1304.4605 Post-employment restrictions. (a) General Restrictions Applicable...

  20. ICF ignition capsule neutron, gamma ray, and high energy x-ray images

    Science.gov (United States)

    Bradley, P. A.; Wilson, D. C.; Swenson, F. J.; Morgan, G. L.

    2003-03-01

    Post-processed total neutron, RIF neutron, gamma-ray, and x-ray images from 2D LASNEX calculations of burning ignition capsules are presented. The capsules have yields ranging from tens of kilojoules (failures) to over 16 MJ (ignition), and their implosion symmetry ranges from prolate (flattest at the hohlraum equator) to oblate (flattest towards the laser entrance hole). The simulated total neutron images emphasize regions of high DT density and temperature; the reaction-in-flight neutrons emphasize regions of high DT density; the gamma rays emphasize regions of high shell density; and the high energy x rays (>10 keV) emphasize regions of high temperature.

  1. Preparatory procedure and equipment for the European x-ray free electron laser cavity implementation

    Directory of Open Access Journals (Sweden)

    D. Reschke

    2010-07-01

    Full Text Available The European x-ray free electron laser is under construction at Deutsches Elektronen-Synchrotron (DESY. The electron beam energy of up to 17.5 GeV will be achieved by using superconducting accelerator technology. Final prototyping, industrialization, and new infrastructure are the actual challenges with respect to the accelerating cavities. This paper describes the preparation strategy optimized for the cavity preparation procedure in industry. For the industrial fabrication and preparation, several new hardware components have been already developed at DESY. The design and construction of a semiautomated rf-measurement machine for dumbbells and end groups are described. In a collaboration among FNAL, KEK, and DESY, an automatic cavity tuning machine has been designed and four machines are under construction. The functionality of these machines with special attention to safety aspects is described in this paper. A new high pressure rinsing system has been developed and is operational.

  2. Approximate P-wave ray tracing and dynamic ray tracing in weakly orthorhombic media of varying symmetry orientation

    KAUST Repository

    Masmoudi, Nabil; Pšenčí k, Ivan

    2014-01-01

    We present an approximate, but efficient and sufficiently accurate P-wave ray tracing and dynamic ray tracing procedure for 3D inhomogeneous, weakly orthorhombic media with varying orientation of symmetry planes. In contrast to commonly used approaches, the orthorhombic symmetry is preserved at any point of the model. The model is described by six weak-anisotropy parameters and three Euler angles, which may vary arbitrarily, but smoothly, throughout the model. We use the procedure for the calculation of rays and corresponding two-point traveltimes in a VSP experiment in a part of the BP benchmark model generalized to orthorhombic symmetry.

  3. The agile alert system for gamma-ray transients

    Energy Technology Data Exchange (ETDEWEB)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Fioretti, V. [INAF/IASF-Bologna, Via Gobetti 101, I-40129 Bologna (Italy); Tavani, M.; Argan, A.; Trois, A.; Scalise, E. [INAF/IASF-Roma, Via del Fosso del Cavaliere 100, I-00133 Roma (Italy); Parmiggiani, N.; Beneventano, D. [University of Modena and Reggio Emilia, Dipartimento di Science e Metodi dell' Ingegneria (Italy); Chen, A. W. [INAF/IASF-Milano, Via E. Bassini 15, I-20133 Milano (Italy); Vercellone, S. [School of Physics, University of the Witwatersrand, Johannesburg Wits 2050 (South Africa); Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P. [INAF/IASF-Palermo, Via U. La Malfa 153, I-90146 Palermo (Italy); Longo, F. [ASI-ASDC, Via G. Galilei, I-00044 Frascati (Roma) (Italy); Pellizzoni, A. [INFN Trieste, I-34127 Trieste (Italy); and others

    2014-01-20

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  4. The agile alert system for gamma-ray transients

    International Nuclear Information System (INIS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Fioretti, V.; Tavani, M.; Argan, A.; Trois, A.; Scalise, E.; Parmiggiani, N.; Beneventano, D.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Longo, F.; Pellizzoni, A.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  5. The AGILE Alert System for Gamma-Ray Transients

    Science.gov (United States)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Parmiggiani, N.; Fioretti, V.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Beneventano, D.; Argan, A.; Trois, A.; Scalise, E.; Longo, F.; Pellizzoni, A.; Pucella, G.; Colafrancesco, S.; Conforti, V.; Tempesta, P.; Cerone, M.; Sabatini, P.; Annoni, G.; Valentini, G.; Salotti, L.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  6. No pain: no gain: The complex art of soft x-ray laser target design and analysis

    International Nuclear Information System (INIS)

    Rosen, M.D.; London, R.A.; Hagelstein, P.L.

    1988-01-01

    We review our methodologies in the design and analysis of soft x-ray laser experiments. We convolve large scale 2-D hydro code output with detailed atomic data bases in a kinetics code with 1-D or 2-D line transfer. The time and space dependent level population data is then post processed further with a beam transport code, including refraction, to predict actual experimental results. While mysteries do remain, we present many examples that show how this complex modeling procedure is crucial in explaining experimental results

  7. The role of human error in risk analysis: Application to pre- and post-maintenance procedures of process facilities

    International Nuclear Information System (INIS)

    Noroozi, Alireza; Khakzad, Nima; Khan, Faisal; MacKinnon, Scott; Abbassi, Rouzbeh

    2013-01-01

    Human factors play an important role in the safe operation of a facility. Human factors include the systematic application of information about human characteristics and behavior to increase the safety of a process system. A significant proportion of human errors occur during the maintenance phase. However, the quantification of human error probabilities in the maintenance phase has not been given the amount of attention it deserves. This paper focuses on a human factors analysis in pre-and post- pump maintenance operations. The procedures for removing process equipment from service (pre-maintenance) and returning the equipment to service (post-maintenance) are considered for possible failure scenarios. For each scenario, human error probability is calculated for each activity using the Success Likelihood Index Method (SLIM). Consequences are also assessed in this methodology. The risk assessment is conducted for each component and the overall risk is estimated by adding individual risks. The present study is aimed at highlighting the importance of considering human error in quantitative risk analyses. The developed methodology has been applied to a case study of an offshore process facility

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... June is Men's Health Month Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  11. Incidence of postoperative implant-related bacterial endocarditis in dogs that underwent trans-catheter embolization of a patent ductus arteriosus without intra- and post-procedural prophylactic antibiotics

    NARCIS (Netherlands)

    Szatmári, Viktor

    2017-01-01

    Intra- and post-procedural prophylactic antibiotics are routinely administered by veterinary cardiologists to dogs that undergo trans-catheter embolization of a patent ductus arteriosus for prevention of implant-related infective endocarditis. The hypothesis of our study was that primary antibiotic

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the procedure ... diagnose and treat medical conditions. Imaging with x-rays involves exposing a part ...

  13. Hanford site post-NPH building inspection plan

    International Nuclear Information System (INIS)

    Wagenblast, G.R. Westinghouse Hanford

    1996-01-01

    This plan establishes consistent post-NPH building inspection procedures and defines a procedure for prioritization of buildings for inspection to ensure the safety of facilities prior to reentry. Qualification of systems for restart of operation is not included. This plan takes advantage, where possible, of existing national procedures for post-NPH inspection of buildings, of existing structural design and evaluation documentation of Hanford facilities, and current and proposed seismic instrumentation located throughout the Hanford site. A list of buildings, prioritized according to current building safety function and building vulnerability (without regard for or information about a damaging natural forces event) is provided

  14. Study of properties of chemically modified samples of halloysite mineral with X-ray fluorescence and X-ray powder diffraction methods

    International Nuclear Information System (INIS)

    Banaś, D.; Kubala-Kukuś, A.; Braziewicz, J.; Majewska, U.; Pajek, M.; Wudarczyk-Moćko, J.; Czech, K.; Garnuszek, M.; Słomkiewicz, P.; Szczepanik, B.

    2013-01-01

    Elemental and chemical composition of raw and activated samples of halloysite mineral using wavelength dispersive X-ray fluorescence (WDXRF), total reflection X-ray fluorescence (TXRF) and X-ray powder diffraction (XRPD) methods were determined. As the result, it has been shown that application of the complementary X-ray spectrometry techniques allows very precise observation of changes in composition of halloysite mineral samples caused by its chemical modifications. Sample preparation procedure and usability of the research methods applied are described in details. Procedure of activation of raw halloysite mineral samples by etching them in sulfuric acid of various concentrations has been described and discussed. The ability of the samples to adsorb lead from intentionally contaminated water was tested and confirmed. - Author-Highlights: • We measured elemental and chemical composition of raw and activated halloysite mineral samples. • We showed that X-ray techniques allow precise study of changes in the sample composition. • We describe procedure of activation of the samples by etching them in sulfuric acid. • We tested ability of halloysite mineral to absorb lead from contaminated water

  15. No pain-no gain: The complex art of soft x-ray laser target design and analysis

    International Nuclear Information System (INIS)

    Rosen, M.D.; London, R.A.; Hagelstein, P.L.

    1988-01-01

    We review our methodologies in the design and analysis of soft x-ray laser experiments. We convolve large-scale 2-D hydro code output with detailed atomic data bases in a kinetics code with 1-D or 2-D line transfer. The time and space dependent level population data is then post processed further with a beam transport code, including refraction, to predict actual experimental results. While mysteries do remain, we present many examples that show how this complex modeling procedure is crucial in explaining experimental results. 23 refs., 8 figs., 1 tab

  16. Neglected post burns contracture of hand in children: Analysis of contributory socio-cultural factors and the impact of neglect on outcome.

    Science.gov (United States)

    Gupta, Ravi Kumar; Jindal, Nipun; Kamboj, Kulbhushan

    2014-12-01

    No study has ever evaluated the causes and effect of neglect on the outcome of post burns contractures of hand in children. 66 hands in 61 children (mean age 12.22 years) with a mean neglect of 11.6 years (range 5-17 years) were assessed for the causes of neglect and the outcome of surgery. Average follow up was 6.6 years. The results were assessed in two groups of 5-10 years neglect as group I and >10 years neglect as group II. In a total number of 134 contracted rays in 66 hands, the surgical procedures included local Z/V-Y flap (51 rays), cross finger flap (48 rays), full thickness graft (35 rays). Additional external fixator with a distracter was used in 3 patients treated at a delay of 14, 16 and 17 years. 50 (81.96%) patients belonged to rural and slum areas. The reasons for delayed treatment included poverty - 33 patients, lack of awareness of surgical treatment - 16 patients; and indifference of parents - 12 patients. 44 (72.13%) children were illiterates. With treatment the average DASH score improved from 65.10 to 36.90 (p neglect in treatment of post burns contracture include poverty, lack of awareness and illiteracy. All the patients showed significant improvement in function after the surgery. Contractures with higher neglect had significantly inferior outcome.

  17. LASL lens design procedure: simple, fast, precise, versatile

    International Nuclear Information System (INIS)

    Brixner, B.

    1978-11-01

    The Los Alamos Scientific Laboratory general-purpose lens design procedure optimizes specific lens prescriptions to obtain the smallest possible image spots and therefore near-spherical wave fronts of light converging on all images in the field of view. Optical image errors are analyzed in much the same way that they are measured on the optical bench. This lens design method is made possible by using the full capabilities of large electronic computers. First, the performance of the whole lens is sampled with many precisely traced skew rays. Next, lens performance is analyzed with spot diagrams generated by the many rays. Third, lens performance is optimized with a least squares system aimed at reducing all image errors to zero. This statistical approach to lens design uses skew rays and precisely measured ray deviations from ideal image points to achieve greater accuracy than was possible with the classical procedure, which is based on approximate expressions derived from simplified ray traces developed for pencil-and-paper calculations

  18. Psychological impact of prenatal diagnosis and post procedure ...

    African Journals Online (AJOL)

    Prenatal diagnosis is associated with psychological challenges, which may affect the response of women before, during or after the procedure, as well as their decision on the future of an affected pregnancy. This prospective study was to evaluate the psychological impact of prenatal diagnosis, factors that may be ...

  19. Post contract / Project management in Nuclear Malaysia

    International Nuclear Information System (INIS)

    Mohd Jamil Hashim

    2010-01-01

    Full-text: Post contract is a period from issuance certificate of practical completion until final statement of account of the project. If this procedure not completed the whole project will at large, create customers un-satisfaction, contractual obligation not complied, record not completed and financial setback. With the usage terms of contract, standard JKR circulars, treasury circulars and JKR quality manual BKJ will produce new Standard operating procedure, SOP with regards to these matters. In doing so it shall increase customer satisfaction and reduce time to finalise project and provide good record system. Keywords: Post contract, certificate of practical completion, final account, customer satisfaction, Standard operating procedure. (author)

  20. Distribution of X-ray examinations within the Danish population

    International Nuclear Information System (INIS)

    Waltenburg, Hanne N.

    2008-01-01

    Full text: Medical X-ray exposures are the largest source of man-made exposure to ionising radiation in developed countries. Therefore, there is an interest to determine the population dose from medical X-rays, for the population as a whole as well as for selected groups, for instance for different age groups. In order to determine these quantities, knowledge of the frequency of X-ray examinations for different age groups is needed. In Denmark, 95% of all hospitals are public, and more than 95% of all procedures in hospitals are carried out in the public hospitals. Dental X-ray procedures are frequent but contribute very little to the population dose. Excluding dental procedures, only a limited number of X-ray procedures (estimated to be around 5% of the total number) are carried out in private clinics outside the hospitals. To assess the frequencies of X-ray procedures, it is therefore a good approximation to assess only the frequencies of procedures carried out in public hospitals. All of these procedures are registered in a national database. The data stored includes a unique identifier for each patient, sex and year of birth of the patient and the name of the procedure. In addition, data on the age and sex distribution of the population is available from national registers. Due to the presence of the unique identifiers, it is possible to assess not only the total number of examinations carried out, but also the number of examinations for each patient. In 2004, 18% of the population underwent one or more X-ray examinations, with the number of examinations varying from 1 to 101. There are marked differences between the different age groups; with frequencies ranging from 7% for the group of 0 - 4 year olds to 45% for 90+ years. Among the persons examined, more than 50% undergo more than examination, while 9% undergo more than five examinations. The types of examinations also vary considerably for different age groups. E.g., CT examinations constitute 2% of all

  1. Biplanar x-ray fluoroscopy for sacroiliac joint fusion.

    Science.gov (United States)

    Vanaclocha-Vanaclocha, Vicente; Verdú-López, Francisco; Sáiz-Sapena, Nieves; Herrera, Juan Manuel; Rivera-Paz, Marlon

    2016-07-01

    Chronic pain originating from the sacroiliac joint (SI) can cause severe dysfunction. Although many patients respond to conservative management with NSAIDs, some do need further treatment in the form of SI joint fusion (SIJF). To achieve safe and successful SIJF, intraoperative x-ray fluoroscopy is mandatory to avoid serious damages to nearby vascular and neural structures. Each step of the procedure has to be confirmed by anteroposterior (AP) and lateral projections. With a single-arm x-ray, the arch has to be moved back and forth for the AP and lateral projections, and this lengthens the procedure. To achieve the same results in less time, the authors introduced simultaneous biplanar fluoroscopy with 2 x-ray arches. After the patient is positioned prone with the legs spread apart in the so-called Da Vinci position, one x-ray arch for the lateral projection is placed at a right angle to the patient, and a second x-ray machine is placed with its arch between the legs of the patient. This allows simultaneous AP and lateral x-ray projections and, in the authors' hands, markedly speeds up the procedure. Biplanar fluoroscopy allows excellent AP and lateral projections to be made quickly at any time during the surgical procedure. This is particularly useful in cases of bilateral SI joint fusion if both sides are done at the same time. The video can be found here: https://youtu.be/TX5gz8c765M .

  2. Using a standards committee to design practical procedure system improvements

    International Nuclear Information System (INIS)

    Grider, D.A.; Plung, D.

    1993-01-01

    In the post-Three Mile Island (TMI) environment, numerous reports have been issued on how to improve the quality of procedures used at government and commercial nuclear facilities. The studies tend to be long on what is wrong with existing procedures and short on practical directions on how to fix those faults. Few of these studies have been conducted by practitioners with full-time procedure-managing or procedure writing experience. None of these studies go into detail on how to improve the procedure system itself. Over the last 10 yr, various nuclear facilities within the US Department of Energy (DOE) have carried out individual programs to develop procedures that meet post-TMI standards. However, ∼2 yr ago, DOE formed a Procedures Standards Committee to advise DOE in developing a set of post-TMI guidelines that could be consistently applied throughout all DOE nuclear facilities. The committee has achieved not only its original mission by producing a series of integrated guidance documents but has also evolved a systems approach to procedures management that sets new standards for procedure quality and efficiency. As members of this committee, the authors want to describe what has made the group's approach so successful. The lessons learned may be translatable to a wide range of government and commercial industry procedure programs

  3. Forthcoming indefinite contract review procedure

    CERN Multimedia

    Human Resources Department

    2011-01-01

    The vacancy notices for posts opened with a view to the award of an indefinite contract will be published in early April 2011. In the meantime, the list of posts to be opened this spring is available at the following address: Indefinite contract posts - spring 2011 A second exercise will take place in autumn 2011 and, as of 2012, the indefinite contract award procedure will only be held once a year, in autumn. For more information please consult: https://hr-recruit.web.cern.ch/hr-recruit/staff/IndefiniteContracts.asp  

  4. X-ray spot film device

    International Nuclear Information System (INIS)

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  5. X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation

    International Nuclear Information System (INIS)

    Hodoroaba, V.-D.; Radtke, M.; Vincze, L.; Rackwitz, V.; Reuter, D.

    2010-01-01

    X-ray scattering may contribute significantly to the spectral background of X-ray fluorescence (XRF) spectra. Based on metrological measurements carried out with a scanning electron microscope (SEM) having attached a well characterised X-ray source (polychromatic X-ray tube) and a calibrated energy dispersive X-ray spectrometer (EDS) the accuracy of a physical model for X-ray scattering is systematically evaluated for representative samples. The knowledge of the X-ray spectrometer efficiency, but also of the spectrometer response functions makes it possible to define a physical spectral background of XRF spectra. Background subtraction relying on purely mathematical procedures is state-of-the-art. The results produced by the analytical model are at least as reliable as those obtained by Monte-Carlo simulations, even without considering the very challenging contribution of multiple scattering. Special attention has been paid to Compton broadening. Relevant applications of the implementation of the analytical model presented in this paper are the prediction of the limits of detection for particular cases or the determination of the transmission of X-ray polycapillary lenses.

  6. Quality control procedure for dental x-ray film processing

    International Nuclear Information System (INIS)

    Tingey, D.R.C.

    1983-08-01

    Methods of obtaining the optimum processing from dental films are discussed. A method of quality control of developing conditions for dental x-ray films has been developed. It is relatively easy to maintain and is sufficiently accurate for practical purposes

  7. Radiation doses in endoscopic interventional procedures

    International Nuclear Information System (INIS)

    Tsapaki, V.; Paraskeva, K.; Mathou, N.; Aggelogiannopoulou, P.; Triantopoulou, C.; Karagianis, J.; Giannakopoulos, A.; Paspatis, G.; Voudoukis, E.; Athanasopoulos, N.; Lydakis, I.; Scotiniotis, H.; Georgopoulos, P.; Finou, P.; Kadiloru, E.

    2012-01-01

    Purpose: Extensive literature exists on patient radiation doses in various interventional procedures. This does not stand for endoscopic retrograde cholangiopancreatography (ERCP) where the literature is very limited. This study compares patient dose during ERCP procedures performed with different types of X-ray systems. Methods and Materials: Four hospitals participated in the study with the following X-ray systems: A) X-ray conventional system (X-ray tube over table), 137 pts, B) X-ray conventional system (X-ray tube under table), 114 pts, C) C-arm system, 79 pts, and D) angiography system, 57 pts. A single experienced endoscopist performed the ERCP in each hospital. Kerma Area Product (KAP), fluoroscopy time (T) and total number of X-ray films (F) were collected. Results: Median patient dose was 6.2 Gy.cm 2 (0.02-130.2 Gy.cm 2 ). Medium linear correlation between KAP and T (0.6) and F (0.4) were observed. Patient doses were 33 % higher than the reference value in UK (4.15 Gy.cm 2 with a sample of 6089 patients). Median KAP for each hospital was: A) 3.1, B) 9.2, C) 3.9 and D) 6.2 Gy.cm 2 . Median T was: A) 2.6, B) 4.1, C) 2.8 and D) 3.4 min. Median F was: A) 2, B) 7, C) 2 and D) 2 films. Conclusion: Patient radiation dose during ERCP depends on: a) fluoroscopy time and films taken, b) the type of the X-ray system used, with the C arm and the conventional over the couch systems carrying the lower patient radiation dose and the angiography system the higher. (authors)

  8. Correction for gamma-ray self-attenuation in regular heterogeneous materials

    International Nuclear Information System (INIS)

    Parker, J.L.

    1981-09-01

    A procedure for determining the total correction factor for gamma-ray self-attenuation in regular heterogeneous materials is derived and discussed. The result of a practical application of the procedure to the passive gamma-ray assay of the 235 U content of high-temperature gas reactor fuel is presented

  9. SU-E-J-23: Characteristics of X-Rays From ExacTrac and Patient Dose From Imaging Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Ding, G [Vanderbilt University, Nashville, TN (United States)

    2015-06-15

    Purpose: The purpose of this investigation is 1) provide the beam characteristics of x-rays produced by a Novalis TX ExacTrac system; 2) present a method to commission such beams, 3) present radiation dose to patients resulting from the imaging procedures. Methods: The Monte Carlo simulations were used to obtain the characteristics of kV beams and validated by measurements. The calculated beam HVLs, profiles and depth-dose curves were benchmarked against measurements. Twelve different image acquisition protocols were studied. The x-ray tube voltage ranges from 70 - 145 kV and milliampere-second (mAs) ranges from 8 - 80 mAs depending on the selection of Cranium, Head & Neck, Thorax or Abdomen imaging protocols. The beam output of each image acquisition protocol was determined by using an ionization chamber. The air kerma calibration factors of the ion chamber were obtained from an Accredited Dosimetry Calibration Laboratory for specified HVLs. Results: The agreements between measured and simulated results were within the uncertainties for HVLs, dose profiles and depth-dose curves. When %dd was normalized at 1 cm depth, its values at depth of 5 cm ranged from 45% to 66% of in water for kV beams range from 70 kVp to 145 kVp respectively. For head images, a typical dose to eye resulting from single projection ranged from 0.008 cGy to 0.025 cGy depending on the cranial image protocols selected. For a single pelvic image the skin dose could reach up to 0.1 cGy from an abdominal protocol. Conclusion: Although multiple pairs of x-ray images are commonly acquired during a daily patient treatment, the imaging doses to patients resulting from the sum of these projected x-rays are generally much less than 0.5 cGy. The knowledge obtained from this investigation can be used to estimate the image dose and optimize the used of the system.

  10. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization

    International Nuclear Information System (INIS)

    Holmes, D.R. Jr.; Bove, A.A.; Wondrow, M.A.; Gray, J.E.

    1986-01-01

    A newly developed video x-ray progressive scanning system improves image quality, decreases radiation exposure, and can be added to any pulsed fluoroscopic x-ray system using a video display without major system modifications. With use of progressive video scanning, the radiation entrance exposure rate measured with a vascular phantom was decreased by 32 to 53% in comparison with a conventional fluoroscopic x-ray system. In addition to this substantial decrease in radiation exposure, the quality of the image was improved because of less motion blur and artifact. Progressive video scanning has the potential for widespread application to all pulsed fluoroscopic x-ray systems. Use of this technique should make cardiac catheterization procedures and all other fluoroscopic procedures safer for the patient and the involved medical and paramedical staff

  11. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. 19 CFR 181.33 - Customs processing procedures.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Customs processing procedures. 181.33 Section 181.33 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF....33 Customs processing procedures. (a) Status determination. After receipt of a post-importation claim...

  13. Planetary gamma-ray spectroscopy: the effects of hydrogen absorption cross-section of the gamma-ray spectrum

    International Nuclear Information System (INIS)

    Lapides, J.R.

    1981-01-01

    The gamma-ray spectroscopy of planet surfaces is one of several possible methods that are useful in determining the elemental composition of planet surfaces from orbiting spacecraft. This has been demonstrated on the Apollos 15 and 16 missions as well as the Soviet Mars-5 mission. Planetary gamma-ray emission is primarily the result of natural radioactive decay and cosmic-ray and solar-flare-induced nuclear reactions. Secondary neutron reactions play a large role in the more intense gamma-ray emission. The technique provides information on the elemental composition of the top few tens of centimeters of the planet surface. Varying concentrations of hydrogen and compositional variations that alter the macroscopic thermal-neutron absorption cross section have a significant effect on the neutron flux in the planet surface and therefore also on the gamma-ray emission from the surface. These effects have been systematically studied for a wide range of possible planetary compositions that include Mercury, the moon, Mars, the comets, and the asteroids. The problem of the Martian atmosphere was also investigated. The results of these calculations, in which both surface neutron fluxes and gamma-ray emission fluxes were determined, were used to develop general procedures for obtaining planet compositions from the gamma-ray spectrum. Several changes have been suggested for reanalyzing the Apollos 15 and 16 gamma-ray results. In addition, procedures have been suggested that can be applied to neutron-gamma techniques in mineral and oil exploration

  14. X-ray guided biopsy

    International Nuclear Information System (INIS)

    Casanova, R.; Lezana, A.H.; Pedrosa, C.S.

    1980-01-01

    Fine needle aspiration biopsy (FNAB) is now a routine procedure in many X-ray Departments. This paper presents the authors' experience with this technique in chest, abdominal and skeletal lesions. (Auth.)

  15. Value of Nonrigid Registration of Pre-Procedure MR with Post-Procedure CT After Radiofrequency Ablation for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil; Lee, Jeong Min, E-mail: jmlshy2000@gmail.com, E-mail: jmsh@snu.ac.kr; Lee, Dong Ho; Joo, Ijin; Yoon, Jeong Hee [Seoul National University Hospital, Department of Radiology (Korea, Republic of); Park, Jin Young [Dongnam Institute of Radiological and Medical Sciences, Department of Radiology (Korea, Republic of); Klotz, Ernst [Siemens Healthineers, Computed Tomography (Germany)

    2017-06-15

    PurposeTo evaluate the value of pre-radiofrequency ablation (RFA) MR and post-RFA CT registration for the assessment of the therapeutic response of hepatocellular carcinoma (HCC).Materials and MethodsA total of 178 patients with single HCC who received RFA as an initial treatment and had available pre-RFA MR and post-RFA CT images were included in this retrospective study. Two independent readers (one experienced radiologist, one inexperienced radiologist) scored the ablative margin (AM) of treated tumors on a four-point scale (1, residual tumor; 2, incomplete AM; 3, borderline AM; 4, sufficient AM), in two separate sessions: (1) visual comparison between pre-and post-RFA images; (2) with addition of nonrigid registration for pre- and post-RFA images. Local tumor progression (LTP) rates between low-risk (response score, 3–4) and high-risk groups (1–2) were analyzed using the Kaplan–Meier method at each interpretation session.ResultsThe patients’ reassignments after using the registered images were statistically significant for inexperienced reader (p < 0.001). In the inexperienced reader, LTP rates of low- and high-risk groups were significantly different with addition of registered images (session 2) (p < 0.001), but not significantly different in session 1 (p = 0.101). However, in the experienced reader, LTP rates of low- and high-risk groups were significantly different in both interpretation sessions (p < 0.001). Using the registered images, the cumulative incidence of LTP at 2 years was 3.0–6.6%, for the low-risk group, and 18.6–27.8% for the high-risk group.ConclusionRegistration between pre-RFA MR and post-RFA CT images may allow better assessment of the therapeutic response of HCC after RFA, especially for inexperienced radiologists, helping in the risk stratification for LTP.

  16. Playing the Panopticon : Procedural punishment in Dark Souls

    NARCIS (Netherlands)

    van Nuenen, Tom

    2015-01-01

    This article investigates discursive procedures in From Software’s 2011 videogame Dark Souls. By combining procedural rhetorics, discourse analysis, and autoethnographical research play, it is argued that Dark Souls features post-Panoptical gameplay mechanics of both continuous surveillance and

  17. Wavefront coherence area for predicting visual acuity of post-PRK and post-PARK refractive surgery patients

    Science.gov (United States)

    Garcia, Daniel D.; van de Pol, Corina; Barsky, Brian A.; Klein, Stanley A.

    1999-06-01

    Many current corneal topography instruments (called videokeratographs) provide an `acuity index' based on corneal smoothness to analyze expected visual acuity. However, post-refractive surgery patients often exhibit better acuity than is predicted by such indices. One reason for this is that visual acuity may not necessarily be determined by overall corneal smoothness but rather by having some part of the cornea able to focus light coherently onto the fovea. We present a new method of representing visual acuity by measuring the wavefront aberration, using principles from both ray and wave optics. For each point P on the cornea, we measure the size of the associated coherence area whose optical path length (OPL), from a reference plane to P's focus, is within a certain tolerance of the OPL for P. We measured the topographies and vision of 62 eyes of patients who had undergone the corneal refractive surgery procedures of photorefractive keratectomy (PRK) and photorefractive astigmatic keratectomy (PARK). In addition to high contrast visual acuity, our vision tests included low contrast and low luminance to test the contribution of the PRK transition zone. We found our metric for visual acuity to be better than all other metrics at predicting the acuity of low contrast and low luminance. However, high contrast visual acuity was poorly predicted by all of the indices we studied, including our own. The indices provided by current videokeratographs sometimes fail for corneas whose shape differs from simple ellipsoidal models. This is the case with post-PRK and post-PARK refractive surgery patients. Our alternative representation that displays the coherence area of the wavefront has considerable advantages, and promises to be a better predictor of low contrast and low luminance visual acuity than current shape measures.

  18. Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator

    International Nuclear Information System (INIS)

    2002-01-01

    This practice outlines dosimetric procedures to be followed with self-contained dry-storage gamma-ray irradiators. If followed, these procedures will help to ensure that calibration and testing will be carried out with acceptable precision and accuracy and that the samples processed with ionizing radiation from gamma rays in a self-contained dry-storage irradiator receive absorbed doses within a predetermined range. This practice covers dosimetry in the use of dry-storage gamma-ray irradiators, namely self-contained dry storage 137 Cs or 60 Co irradiators (shielded free-standing irradiators). It does not cover underwater pool sources, panoramic gamma-ray sources such as those raised mechanically or pneumatically to irradiate isotropically into a room or through a collimator, nor does it cover self-contained bremsstrahlung x-ray units. The absorbed dose range for the use of the dry-storage self-contained gamma-ray irradiators covered by this practice is typically 1 to 10 5 Gy, depending on the application. The absorbed-dose rate range typically is from 10 -2 to 10 3 Gy/min. This practice describes general procedures applicable to all self-contained dry-storage gamma-ray irradiators. For procedures specific to dosimetry in blood irradiation, see ISO/ ASTM Practice 51939. For procedures specific to dosimetry in radiation research on food and agricultural products, see ISO/ASTM Practice 51900. For procedures specific to radiation hardness testing, see ASTM Practice E 1249. For procedures specific to the dosimetry in the irradiation of insects for sterile release programs, see ISO/ASTM Guide 51940. In those cases covered by ISO/ASTM Practices 51939, 51900, 51940, or ASTM E 1249, those standards take precedence. In addition, this practice does not cover absorbed-dose rate calibrations of radiation protection instrumentation

  19. SENDS criteria from the diversification of MAST procedures. Implementation of preoperative simulation

    International Nuclear Information System (INIS)

    Rieger, B.

    2015-01-01

    Minimal access spinal technologies (MAST) lead to a diversification of surgical procedures, which requires careful selection of the procedure and outcome monitoring. For a rational selection of the procedure simulation, endoscopy, navigation, decompression and stabilization (SENDS) criteria can be derived from the development of the MAST procedures. Preoperative simulation has diagnostic and therapeutic values. The SENDS criteria can be verified indirectly via outcome control. Biomechanically meaningful diagnostic x-rays of the spinal segment to be surgically treated are currently carried out with the patient in inclination and reclination. Software-related preoperative simulation based on these x-ray images facilitates the selection and implementation of the MAST procedure. For preoperative simulation motion shots are needed in inclination, neutral position and reclination and the dimensions can be obtained using an x-ray ball or a computed tomography (CT) scan. The SENDS criteria are useful because established procedures based on these criteria reach a comparable outcome. Preoperative simulation appears to be a useful selection criterion. Preoperatively it is necessary to collate patient and segment information in order to provide each patient with individualized treatment. So far there is no evidence for a better outcome after preoperative simulation but a reduction of surgery time and intraoperative radiation exposure could already be demonstrated. Minimally invasive methods should be preferred if there is a comparable outcome. The establishment of new procedures has to be accompanied by the maintenance of a spine register. Minimally invasive surgical procedures should be individualized for each patient and segment. Mobility X-ray images should be prepared for use with the preoperative simulation as the information content significantly increases with respect to the MAST procedure. (orig.) [de

  20. Time course of enhancement of chromosomal aberration production in human lyphocytes by post-treatment with aphidicolin following X-radiation

    International Nuclear Information System (INIS)

    Bender, M.A.

    1989-01-01

    The authors have shown earlier that the DNA polymerase inhibitor, aphidicolin, enhances the production of chromosomal aberration by X-rays when administered as a post-treatment. The effect is marked in metaphases collected for the first hour or two following irradiation. Because the yield of X-ray-induced chromosome aberrations falls rapidly with increasing irradiation-fixation interval in G 2 cells it is possible that a difference in yield between cells post-treated with a drug like aphidicolin and those not-treated could arise simply through alteration of the time required for post-treated cells to reach metaphase. The results of the present experiments agree with those of the earlier one in that the X-ray and X-ray plus 1.5 h 5 x 10 -5 M aphidicolin post-treatment-induced chromatid aberration yield fall very rapidly with increasing X-ray-fixation interval, with the marked excess caused by the post-treatment rapidly disappearing and the yield for post-treated samples fixed between 3 and 6 h post-irradiation becoming no greater than those for samples treated with X-rays alone. The answer to the question of whether the yields increase again at later irradiation-fixation intervals, though complicated by the greater delay in aphidicolin post-treated samples and by admixture at later fixation times of metaphases that were in G 1 when irradiated, appears clearly to be yes. (author). 15 refs.; 3 figs.; 3 figs.; 2 tabs

  1. The measurement of stress and phase fraction distributions in pre and post-transition Zircaloy oxides using nano-beam synchrotron X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Swan, H., E-mail: helen.swan@nnl.co.uk [National Nuclear Laboratory, Building D5, Culham Science Centre, Abingdon, Oxfordshire, OX14 3DB (United Kingdom); Blackmur, M.S., E-mail: matthew.s.blackmur@nnl.co.uk [National Nuclear Laboratory, Building D5, Culham Science Centre, Abingdon, Oxfordshire, OX14 3DB (United Kingdom); Hyde, J.M., E-mail: jonathan.m.hyde@nnl.co.uk [National Nuclear Laboratory, Building D5, Culham Science Centre, Abingdon, Oxfordshire, OX14 3DB (United Kingdom); Laferrere, A., E-mail: alice.laferrere@atkinsglobal.com [W.S.Atkins, The Hub, Aztec West, 500 Park Ave, Almondsbury, Bristol BS32 4RZ (United Kingdom); Ortner, S.R., E-mail: susan.r.ortner@nnl.co.uk [National Nuclear Laboratory, Building D5, Culham Science Centre, Abingdon, Oxfordshire, OX14 3DB (United Kingdom); Styman, P.D., E-mail: paul.d.styman@nnl.co.uk [National Nuclear Laboratory, Building D5, Culham Science Centre, Abingdon, Oxfordshire, OX14 3DB (United Kingdom); Staines, C., E-mail: cassie.staines@nnl.co.uk [National Nuclear Laboratory, 102B, Stonehouse Park, Stonehouse, Gloucestershire, GL10 3UT (United Kingdom); Gass, M., E-mail: mhairi.gass@amecfw.com [Amec Foster Wheeler Clean Energy Europe, Walton House, Birchwood, WA3 6GA (United Kingdom); Hulme, H., E-mail: helen.hulme@amecfw.com [Amec Foster Wheeler Clean Energy Europe, Walton House, Birchwood, WA3 6GA (United Kingdom); Cole-Baker, A., E-mail: aidan.cole-baker@rolls-royce.com [Rolls-Royce plc, PO Box 2000, Derby, DE21 7XX (United Kingdom); Frankel, P., E-mail: philipp.frankel@manchester.ac.uk [Materials Performance Centre, School of Materials, The University of Manchester, Manchester, M13 9PL (United Kingdom)

    2016-10-15

    Zircaloy-4 oxide stress profiles and tetragonal:monoclinic oxide phase fraction distributions were studied using nano-beam transmission X-ray diffraction. Continuous stress relief and phase transformation during the first cycle of oxide growth was observed. The in-plane monoclinic stress was shown to relax strongly up to each transition, whereas in-plane tetragonal stress-relief (near the metal-oxide interface) was only observed post transition. The research demonstrates that plasticity in the metal and the development of a band of in-plane cracking both relax the monoclinic in-plane stress. The observations are consistent with a model of transition in which in-plane cracking becomes interlinked prior to transition. These cracks, combined with the development of cracks with a through-thickness component (driven primarily by plasticity in the metal) and/or a porous network of fine cracks (associated with phase transformation), form a percolation path through the oxide layer. The oxidising species can then percolate from the oxide surface to the metal/oxide interface, at which stage transition then ensues. - Highlights: • Measurement of stress in Zr-4 oxides using nano-beam transmission X-ray diffraction. • In-plane monoclinic stress relaxes strongly up to each transition. • In-plane tetragonal stress relaxation is only observed post transition. • Development of band of cracking is related to monoclinic in-plane stress relaxation. • Linking of in-plane cracking with through-plane crack/porosity leads to transition.

  2. Novel pattern of postray de novo DNA synthesis in a radioresistant human strain

    International Nuclear Information System (INIS)

    Mirzayans, R.; Gentner, N.E.; Paterson, M.C.

    1985-01-01

    Enhanced resistance to radiation cytotoxicity in a fibroblast strain from an afflicted member of a Li-Fraumeni syndrome family may be largely ascribable to a change in the pattern of DNA replicative synthesis following γ ray exposure. That is, the extent of the initial radiogenic inhibition of replicative synthesis and the time interval before its subsequent recovery were both found to be greater in radioresistant (RR) compared to normal cells. In addition, the post-recovery replication rates in the RR cells were both higher and longer lasting than those in the control cells. A similar differential pattern was also seen following treatment with 4NQO, another DNA-damaging agent to which this RR strain displays enhanced resistance. Moreover, several conventional DNA repair assays indicated that the RR cells repair radiogenic damage at normal rates. The authors therefore suggest that the increased inhibition and prolonged lag in resumption of replicative synthesis seen in the RR strain upon exposure to certain genotoxic agents may enhance cellular recovery by ''buying additional time'' for processing of potentially lethal lesions

  3. Plane wave scattering by bow-tie posts

    Science.gov (United States)

    Lech, Rafal; Mazur, Jerzy

    2004-04-01

    The theory of scattering in free space by a novel structure of a two-dimensional dielectric-metallic post is developed with the use of a combination of a modified iterative scattering procedure and an orthogonal expansion method. The far scattered field patterns for open structures are derived. The rotation of the post affects its scattered field characteristic, which permits to make adjustments in characteristic of the posts arrays.

  4. Teflon injections in post-prostatectomy incontinence

    DEFF Research Database (Denmark)

    Osther, P J; Røhl, H F

    1988-01-01

    Twenty-five males with post-prostatectomy incontinence due to sphincter damage underwent transperineal or transurethral Teflon injections. The results were classified into three grades: good, moderate, and poor. Good or moderate results were obtained in 24%. No major immediate complications...... or longterm side-effects were observed. This intervention is associated with a minimum of discomfort for the patient and hospitalization can be limited to 48-72 hours. The results are not so good as those obtained in female incontinence, and the procedure cannot be recommended as first choice treatment...... in patients with post-prostatectomy incontinence, but because of the simplicity of the procedure, it is considered to be a valuable alternative in patients not suitable for prosthetic surgery....

  5. Accident Sequence Evaluation Program: Human reliability analysis procedure

    International Nuclear Information System (INIS)

    Swain, A.D.

    1987-02-01

    This document presents a shortened version of the procedure, models, and data for human reliability analysis (HRA) which are presented in the Handbook of Human Reliability Analysis With emphasis on Nuclear Power Plant Applications (NUREG/CR-1278, August 1983). This shortened version was prepared and tried out as part of the Accident Sequence Evaluation Program (ASEP) funded by the US Nuclear Regulatory Commission and managed by Sandia National Laboratories. The intent of this new HRA procedure, called the ''ASEP HRA Procedure,'' is to enable systems analysts, with minimal support from experts in human reliability analysis, to make estimates of human error probabilities and other human performance characteristics which are sufficiently accurate for many probabilistic risk assessments. The ASEP HRA Procedure consists of a Pre-Accident Screening HRA, a Pre-Accident Nominal HRA, a Post-Accident Screening HRA, and a Post-Accident Nominal HRA. The procedure in this document includes changes made after tryout and evaluation of the procedure in four nuclear power plants by four different systems analysts and related personnel, including human reliability specialists. The changes consist of some additional explanatory material (including examples), and more detailed definitions of some of the terms. 42 refs

  6. Dose Matters: FDA's Guidance on Children's X-rays

    Science.gov (United States)

    ... Consumer Updates Dose Matters: FDA's Guidance on Children's X-rays Share Tweet Linkedin Pin it More sharing options ... exposure during medical procedures. The level of ionizing radiation from X-ray imaging is generally very low, but can ...

  7. Headache following intracranial neuroendovascular procedures.

    Science.gov (United States)

    Baron, Eric P; Moskowitz, Shaye I; Tepper, Stewart J; Gupta, Rishi; Novak, Eric; Hussain, Muhammad Shazam; Stillman, Mark J

    2012-05-01

    Predicting who will develop post-procedure headache (PPH) following intracranial endovascular procedures (IEPs) would be clinically useful and potentially could assist in reducing the excessive diagnostic testing so often obtained in these patients. Although limited safety data exist, the use of triptans or dihydroergotamine (DHE) often raise concern when used with pre/post-coiled aneurysms. We sought to determine risk factors for PPH following IEP, to evaluate the utility of diagnostic testing in patients with post-coil acute headache (HA), and to record whether triptans and DHE have been used safely in this clinical setting. We conducted a retrospective chart review of adult patients undergoing IEPs. Bivariate analyses were conducted to compare patients who did and did not develop PPH. We reviewed records pertaining to 372 patients, of whom 263 underwent intracranial coil embolizations, 21 acrylic glue embolizations, and 88 stent placements. PPH occurred in 72% of coil patients, 33% of glue patients, and 14% of stent patients. Significant risk factors for post-coil HA were female gender, any pre-coil HA history, smoking, and anxiety/depression. A pre-stent history of HA exceeding 1 year's duration, and smoking were risk factors for post-stent HA. A pre-glue history of HA exceeding 1 year was the only risk factor for post-glue HA. In the small subgroup available for study, treatment with triptans or DHE was not associated with adverse events in pre/post-coiled aneurysms. Diagnostic testing was low yield. Occurrence of PPH was common after IEPs and especially so with coiling and in women, smokers, and those with anxiety/depression, and was often of longer duration than allowed by current International Classification of Headache Disorders-II criteria. The yield of diagnostic testing was low, and in a small subgroup treatment with triptans or DHE did not cause adverse events in pre/post-coiled aneurysms. Prospective studies are needed to confirm these findings.

  8. Characterization of Metalloproteins and Biomaterials by X-ray Absorption Spectroscopy and X-ray Diffraction

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl

    This thesis presents thework on combining complementary X-rays techniques for studying the structures of proteins and other biomaterials, and consists of three different projects: (i) Characterization of protein powders with X-ray powder diffraction (XRPD). (ii) The combination of X-ray...... crystallography and X-ray absorption spectroscopy (XAS) applied to studying different hexameric insulin conformations. (iii) The structures of polymorphs of strontium ranelate and the distribution of strontium in bone tissue. A procedure for fast identification and verification of protein powders using XRPD...... was correction for disordered bulk-solvent, but also correction for background and optimization of unit cell parameters have to be taken into account. A sample holder was designed for collecting powder diffraction data on a standard laboratory X-ray powder diffractometer. The background was reduced by use...

  9. Groin hematoma after electrophysiological procedures-incidence and predisposing factors.

    Science.gov (United States)

    Dalsgaard, Anja Borgen; Jakobsen, Christina Spåbæk; Riahi, Sam; Hjortshøj, Søren

    2014-10-01

    We evaluated the incidence and predisposing factors of groin hematomas after electrophysiological (EP) procedures. Prospective, observational study, enrolling consecutive patients after EP procedures (Atrial fibrillation: n = 151; Supraventricular tachycardia/Diagnostic EP: n = 82; Ventricular tachycardia: n = 18). Patients underwent manual compression for 10 min and 3 h post procedural bed rest. AF ablations were performed with INR 2-3, ACT > 300, and no protamine sulfate. Adhesive pressure dressings (APDs) were used if sheath size ≥ 10F; procedural time > 120 min; and BMI > 30. Patient-reported hematomas were recorded by a telephone follow-up after 2 weeks. Hematoma developed immediately in 26 patients (10%) and after 14 days significant hematoma was reported in 68 patients (27%). Regression analysis on sex, age, BMI 25, ACT 300, use of APD, sheath size and number, and complicated venous access was not associated with hematoma, either immediately after the procedure or after 14 days. Any hematoma presenting immediately after procedures was associated with patient-reported hematomas after 14 days, odds ratio 18.7 (CI 95%: 5.00-69.8; P hematoma immediately after EP procedures was the sole predictor of patient-reported hematoma after 2 weeks. Initiatives to prevent groin hematoma should focus on the procedure itself as well as post-procedural care.

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in metabolic ... to current x-ray images for diagnosis and disease management. top of page How is the procedure ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the baby. See the Safety page for more information about pregnancy and x-rays. top of page ... procedure varies. See the Safety page for more information about radiation dose. Women should always inform their ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? A bone x-ray examination itself ... available in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... foot. top of page What are some common uses of the procedure? A bone x-ray is ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  17. Post-irradiation diarrhea

    International Nuclear Information System (INIS)

    Meerwaldt, J.H.

    1984-01-01

    In radiotherapy of pelvic cancers, the X-ray dose to be delivered to the tumour is limited by the tolerance of healthy surrounding tissue. In recent years, a number of serious complications of irradiation of pelvic organs were encountered. Modern radiotherapy necessitates the acceptance of a calculated risk of complications in order to achieve a better cure rate. To calculate these risks, one has to know the radiation dose-effect relationship of normal tissues. Of the normal tissues most at risk when treating pelvic tumours only the bowel is studied. In the literature regarding post-irradiation bowel complications, severe and mild complications are often mixed. In the present investigation the author concentrated on the group of patients with relatively mild symptoms. He studied the incidence and course of post-irradiation diarrhea in 196 patients treated for carcinoma of the uterine cervix or endometrium. The aims of the present study were: 1) to determine the incidence, course and prognostic significance of post-irradiation diarrhea; 2) to assess the influence of radiotherapy factors; 3) to study the relation of bile acid metabolism to post-irradiation diarrhea; 4) to investigate whether local factors (reservoir function) were primarily responsible. (Auth.)

  18. X-ray Emission from the Guitar Nebula

    OpenAIRE

    Romani, Roger W.; Cordes, James M.; Yadigaroglu, I. -A.

    1997-01-01

    We have detected weak soft X-ray emission from the Pulsar Wind Nebula trailing the high velocity star PSR 2224+65 (the `Guitar Nebula'). This X-ray flux gives evidence of \\gamma~10^7 eV particles in the pulsar wind and constrains the properties of the post-shock flow. The X-ray emission is most easily understood if the shocked pulsar wind is partly confined in the nebula and if magnetic fields in this zone can grow to near equipartition values.

  19. Peer-assisted learning model enhances clinical clerk's procedural skills.

    Science.gov (United States)

    Huang, Chia-Chang; Hsu, Hui-Chi; Yang, Ling-Yu; Chen, Chen-Huan; Yang, Ying-Ying; Chang, Ching-Chih; Chuang, Chiao-Lin; Lee, Wei-Shin; Lee, Fa-Yauh; Hwang, Shinn-Jang

    2018-05-17

    Failure to transfer procedural skills learned in a laboratory to the bedside is commonly due to a lack of peer support/stimulation. A digital platform (Facebook) allows new clinical clerks to share experiences and tips that help augment their procedural skills in a peer-assisted learning/teaching method. This study aims to investigate the effectiveness of the innovation of using the digital platform to support the transfer of laboratory-trained procedural skills in the clinical units. Volunteer clinical clerks (n = 44) were enrolled into the peer-assisted learning (PAL) group, which was characterized by the peer-assisted learning of procedural skills during their final 3-month clinical clerkship block. Other clerks (n = 51) did not join the procedural skills-specific Facebook group and served as the self-directed learning regular group. The participants in both the PAL and regular groups completed pre- and post-intervention self-assessments for general self-assessed efficiency ratings (GSER) and skills specific self-assessed efficiency ratings (SSSER) for performing vein puncture, intravenous (IV) catheter and nasogastric (NG) tube insertion. Finally, all clerks received the post-intervention 3-station Objective Structured Clinical Skills Examination (OSCE) to test their proficiency for the abovementioned three procedural skills. Higher cumulative numbers of vein punctures, IV catheter insertions and NG tube insertions at the bedside were carried out by the PAL group than the regular group. A greater improvement in GSERs and SSSERs for medical procedures was found in the PAL group than in the regular group. The PAL group obtained higher procedural skills scores in the post-intervention OSCEs than the regular group. Our study suggested that the implementation of a procedural skill-specific digital platform effectively helps clerks to transfer laboratory-trained procedural skills into the clinical units. In comparison with the regular self-directed learning

  20. X-ray testing of fiber composite plastics

    International Nuclear Information System (INIS)

    Altmann, O.; Lembke, B.

    1984-01-01

    Besides the ultrasonic test, X-raying is the most important non-destructive test procedure for supporting fibre composite structures. This report presents some auxiliary means and test results regarding the limits of fault detectibility during the X-raying of fiber composite structures, preferrably carbon fiber laminates (CFRP). (orig.) [de

  1. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ray, N.B.

    1977-01-01

    The principle, instrument and procedure of X-ray fluorescence spectrometry are described. It is a rapid, simple and sensitive method for the trace analysis of elements from sodium to uranium in powder, liquid or metal samples. (M.G.B.)

  2. The IHS diagnostic X-ray equipment radiation protection program

    International Nuclear Information System (INIS)

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-01-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload

  3. Post accidental small breaks analysis

    International Nuclear Information System (INIS)

    Depond, G.; Gandrille, J.

    1980-04-01

    EDF ordered to FRAMATOME by 1977 to complete post accidental long term studies on 'First Contrat-Programme' reactors, in order to demonstrate the safety criteria long term compliance, to get information on NSSS behaviour and to improve the post accidental procedures. Convenient analytical models were needed and EDF and FRAMATOME respectively developped the AXEL and FRARELAP codes. The main results of these studies is that for the smallest breaks, it is possible to manually undertake cooling and pressure reducing actions by dumping the steam generators secondary side in order to meet the RHR operating specifications and perform long term cooling through this system. A specific small breaks procedure was written on this basis. The EDF and FRAMATOME codes are continuously improved; the results of a French set of separate effects experiments will be incorporated as well as integral system verification

  4. Post Rule of Law

    DEFF Research Database (Denmark)

    Carlson, Kerstin Bree

    2016-01-01

    The value of developing hybrid international criminal procedure (ICP) is that it is arguably inclusive (representing two major legal traditions) and distinct from any domestic system, thus creating a separate, sui generis realm for international criminal law (ICL) jurists to meet. Since its...... addresses the practice of hybridity in ICP, drawing examples from the construction and evolution of hybrid procedure at the International Criminal Tribunal for the Former Yugoslavia (ICTY), to argue that the hybridity practiced by international criminal tribunals renders them ‘post rule of law’ institutions...

  5. Modern X-ray diffraction. X-ray diffractometry for materials scientists, physicists, and chemicists. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Spiess, Lothar; Teichert, Gerd; Schwarzer, Robert; Behnken, Herfried; Genzel, Christoph

    2009-01-01

    This book offers a comprehensive survey over the applications of X-ray diffractions in fields like materials technique, metallurgy, electrotechniques, mechanical engineering, as well as micro- and nanotechniques. The necessary baic knowledges of X-ray diffraction are mediated foundedly and illustratively. Thereby new techniques and evaluation procedures are presented as well as well known methods

  6. Accident Sequence Evaluation Program: Human reliability analysis procedure

    Energy Technology Data Exchange (ETDEWEB)

    Swain, A.D.

    1987-02-01

    This document presents a shortened version of the procedure, models, and data for human reliability analysis (HRA) which are presented in the Handbook of Human Reliability Analysis With emphasis on Nuclear Power Plant Applications (NUREG/CR-1278, August 1983). This shortened version was prepared and tried out as part of the Accident Sequence Evaluation Program (ASEP) funded by the US Nuclear Regulatory Commission and managed by Sandia National Laboratories. The intent of this new HRA procedure, called the ''ASEP HRA Procedure,'' is to enable systems analysts, with minimal support from experts in human reliability analysis, to make estimates of human error probabilities and other human performance characteristics which are sufficiently accurate for many probabilistic risk assessments. The ASEP HRA Procedure consists of a Pre-Accident Screening HRA, a Pre-Accident Nominal HRA, a Post-Accident Screening HRA, and a Post-Accident Nominal HRA. The procedure in this document includes changes made after tryout and evaluation of the procedure in four nuclear power plants by four different systems analysts and related personnel, including human reliability specialists. The changes consist of some additional explanatory material (including examples), and more detailed definitions of some of the terms. 42 refs.

  7. The completeness of chest X-ray procedure codes in the Danish National Patient Registry

    Directory of Open Access Journals (Sweden)

    Hjertholm P

    2017-03-01

    Full Text Available Peter Hjertholm,1 Kaare Rud Flarup,1 Louise Mahncke Guldbrandt,1 Peter Vedsted1,2 1Research Center for Cancer Diagnosis in Primary Care, Department of Public Health, 2University Clinic for Innovative Health Care Delivery, Diagnostic Centre, Silkeborg Hospital, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark Objective: The aim of this validation study was to assess the completeness of the registrations of chest X-rays (CXR in two different versions of the Danish National Patient Registry (DNPR. Material and methods: We included electronic record data on CXR performed on patients aged 40 to 99 years from nine radiology departments covering 20 Danish hospitals. From each department, we included data from three randomly selected weeks between 2004 and 2011 (reference standard. In two versions of the DNPR from the State Serum Institute (SSI and Statistics Denmark, respectively, we investigated the proportion of registered CXR compared to the reference standard. Furthermore, we compared the completeness of the recorded data according to the responsible department (main department. Results: We identified 11,235 patients and 12,513 CXR in the reference standard. The data from the SSI contained 12,265 (98% CXR, whereas the data from Statistics Denmark comprised 9,151 (73.1% CXR. The completeness of the SSI data was fairly constant across years, radiology departments, medical specialties, and age groups. The data from Statistics Denmark was almost complete in 2011 (95.8%. However, for the remaining study period, the data with radiology departments registered as the main department were lacking in the version from Statistics Denmark, and so the overall completeness was 73.1%. Conclusion: The completeness of CXR registrations varied between 98% and 73% depending on the information source, and this should be considered when investigating radiology services in the basis of DNPR. Keywords: chest X-ray, Danish National Patient Registry

  8. Legal directives in the X-ray regulation for the field of X-ray diagnostics; Rechtsvorschriften der Roentgenverordnung fuer den Bereich der Roentgendiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Huhn, Walter [Ministerium fuer Arbeit, Integration und Soziales des Landes Nordrhein-Westfalen, Duesseldorf (Germany)

    2012-11-01

    The operation of each X-ray device is subject to the requirements of the X-ray regulations (RoeV); for different operational modes or applications like curative diagnostics, X-ray serial examinations, X-ray radiotherapy and teleradiology different directives exist and have to be respected. The report discusses the issues licensing and notification procedures, radiation protection representative, requirements for the commissioning (teleradiology, serial X.ray examinations), technical qualification and radiation protection knowledge of physicians, technical qualification of the assistant personnel.

  9. Effectiveness of gamma ray irradiation and ethyl methane ...

    African Journals Online (AJOL)

    Survival rate and plantlet performance of DNKW001 in gamma ray + EMS 7uM treatment declined profoundly with increasing doses and LD50 was lower (104 Gy) than LD50 in gamma ray irradiation (177 Gy) alone. Variants of plantlets were detected in pre (white streaked leaf and bigger petiole with distorted leaf) and post ...

  10. Portable gamma-ray holdup and attributes measurements of high- and variable-burnup plutonium

    International Nuclear Information System (INIS)

    Wenz, T.R.; Russo, P.A.; Miller, M.C.; Menlove, H.O.; Takahashi, S.; Yamamoto, Y.; Aoki, I.

    1991-01-01

    High burnup-plutonium holdup has been assayed quantitatively by low resolution gamma-ray spectrometry. The assay was calibrated with four plutonium standards representing a range of fuel burnup and 241 Am content. Selection of a calibration standard based on its qualitative spectral similarity to gamma-ray spectra of the process material is partially responsible for the success of these holdup measurements. The spectral analysis method is based on the determination of net counts in a single spectral region of interest (ROI). However, the low-resolution gamma-ray assay signal for the high-burnup plutonium includes unknown amounts of contamination from 241 Am. For most needs, the range of calibration standards required for this selection procedure is not available. A new low-resolution gamma-ray spectral analysis procedure for assay of 239 Pu has been developed. The procedure uses the calculated isotope activity ratios and the measured net counts in three spectral ROIs to evaluate and remove the 241 Am contamination from the 239 Pu assay signal on a spectrum-by-spectrum basis. The calibration for the new procedure requires only a single plutonium standard. The procedure also provides a measure of the burnup and age attributes of holdup deposits. The new procedure has been demonstrated using portable gamma-ray spectroscopy equipment for a wide range of plutonium standards and has also been applied to the assay of 239 Pu holdup in a mixed oxide fuel fabrication facility. 10 refs., 5 figs., 3 tabs

  11. X-ray detectors in medical imaging

    International Nuclear Information System (INIS)

    Spahn, Martin

    2013-01-01

    Healthcare systems are subject to continuous adaptation, following trends such as the change of demographic structures, the rise of life-style related and chronic diseases, and the need for efficient and outcome-oriented procedures. This also influences the design of new imaging systems as well as their components. The applications of X-ray imaging in the medical field are manifold and have led to dedicated modalities supporting specific imaging requirements, for example in computed tomography (CT), radiography, angiography, surgery or mammography, delivering projection or volumetric imaging data. Depending on the clinical needs, some X-ray systems enable diagnostic imaging while others support interventional procedures. X-ray detector design requirements for the different medical applications can vary strongly with respect to size and shape, spatial resolution, frame rates and X-ray flux, among others. Today, integrating X-ray detectors are in common use. They are predominantly based on scintillators (e.g. CsI or Gd 2 O 2 S) and arrays of photodiodes made from crystalline silicon (Si) or amorphous silicon (a-Si) or they employ semiconductors (e.g. Se) with active a-Si readout matrices. Ongoing and future developments of X-ray detectors will include optimization of current state-of-the-art integrating detectors in terms of performance and cost, will enable the usage of large size CMOS-based detectors, and may facilitate photon counting techniques with the potential to further enhance performance characteristics and foster the prospect of new clinical applications

  12. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei

    2015-01-01

    OBJECTIVES: This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. BACKGROUND: A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence...

  13. Quality assurance for diagnostic X-ray machines in Tanzania

    International Nuclear Information System (INIS)

    Sungita, Y.Y.; Mdoe, S.L.; Ngatunga, J.; Kitosi, A.E.; Muhogora, W.E.

    1998-01-01

    In this presentation it is being discussed a close relationship between the prevention of accidents involving apparatus that generates the ionizing radiation (x-ray tubes etc.) and the need to perform quality control procedures and make follow-up corrective maintenance procedures. A summary of results of quality control performance of x-ray machines in certain centers in Tanzania is tabled and measures to overcome some of the observed problems are recommended. The number of X-ray units inspected were 219, out of which 123 were working, 75 were out of order, 6 units were not yet installed and those which are working with faulty parts were 15. The performance of quality assurance for X-Ray units (57) tested showed that 36.8% didn't qualify. About 80% of these equipment are more than 15 years old. (author)

  14. Coracoid process x-ray investigation before Latarjet procedure: a radioanatomic study.

    Science.gov (United States)

    Bachy, Manon; Lapner, Peter L C; Goutallier, Daniel; Allain, Jérôme; Hernigou, Phillipe; Bénichou, Jacques; Zilber, Sébastien

    2013-12-01

    The purpose of this study was to determine whether a preoperative radiologic assessment of the coracoid process is predictive of the amount of bone available for coracoid transfer by the Latarjet procedure. Thirty-five patients with anterior instability undergoing a Latarjet procedure were included. A preoperative radiologic assessment was performed with the Bernageau and true anteroposterior (true AP) views. The length of the coracoid process was measured on both radiographic views and the values were compared with the length of the bone block during surgery. Statistical analysis was carried out by ANOVA and Wilcoxon tests (P process length was 29 ± 4 and 33 ± 4 mm on the Bernageau and true AP views, respectively. The mean bone block length during surgery was 21.6 ± 2.7 mm. A significant correlation was found (P = .032) between the coracoid process length on the true AP view and the intraoperative bone block length. Preoperative planning for the Latarjet procedure, including graft orientation and screw placement, requires knowledge of the length of coracoid bone available for transfer. This can be facilitated with the use of preoperative standard radiographs, thus avoiding computed tomography. This planning allows the detection of coracoid process anatomic variations or the analysis of the remaining part of the coracoid process after failure of a first Latarjet procedure to avoid an iliac bone graft. Radiologic preoperative coracoid process measurement is an easy, reliable method to aid preoperative planning of the Latarjet procedure in primary surgery and reoperations. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  15. Microfocal X-ray computed tomography post-processing operations for optimizing reconstruction volumes of stented arteries during 3D computational fluid dynamics modeling.

    Science.gov (United States)

    Ladisa, John F; Olson, Lars E; Ropella, Kristina M; Molthen, Robert C; Haworth, Steven T; Kersten, Judy R; Warltier, David C; Pagel, Paul S

    2005-08-01

    Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to generate geometrically accurate flow domains within the localized region of a stent several weeks after implantation. Microfocal X-ray CT reconstruction volumes were subjected to an automated program to perform arterial thresholding, spatial orientation, and surface smoothing of stented and unstented rabbit iliac arteries several weeks after antegrade implantation. A transfer function was obtained for the current post-processing methodology containing reconstructed 16 mm stents implanted into rabbit iliac arteries for up to 21 days after implantation and resolved at circumferential and axial resolutions of 32 and 50 microm, respectively. The results indicate that the techniques presented are sufficient to resolve distributions of WSS with 80% accuracy in segments containing 16 surface perturbations over a 16 mm stented region. These methods will be used to test the hypothesis that reductions in normalized wall shear stress (WSS) and increases in the spatial disparity of WSS immediately after stent implantation may spatially correlate with the temporal development of NH within the stented region.

  16. Dextranomer Based Implant (Deflux) for Endoscopic Treatment of Post-Prostatectomy Incontinence

    International Nuclear Information System (INIS)

    Abu-El-Azayem, Khaled M.; Abdel-Meguid, Taha A.; Soliman, S.

    2006-01-01

    Endoscopic treatment for post-prostatectomy urinary incontinence has gained popularity using several inject-able bulking materials. The current study reports our experience with endoscopic submucosal injection of dextranomer/hyaluronic acid copolymer for treatment of post-prostatectomy incontinence due to sphincteric deficiency. A total of 14 patients with post-prostatectomy urinary incontinence; 13 post-trans urethral resection of prostate (TURP) and 1 post-open prostatectomy, were enrolled. The patients aged between 59-85 years. Preoperative evaluation included multi-channel video urodynamics. Patients who had verified intrinsic sphincteric deficiency, adequate bladder capacity, absent unhibited detrusor contractions and minimal or no post void residual (PVR) urine were selected for injection therapy. The standard 4 quadrant sub-mucosal injection technique was utilized. Follow-up was scheduled at 1 month after each injection and at 6-months interval thereafter. A total of 25 procedures were done. Seven patients (50%) received single injection, 3 patients (21.4%) required 2 injections and 4 patients (28.6%) needed 3 injections. The mean volume of injected material was 3.7 mL per procedure (range 2-8). The mean operative time was 30 minutes (range 15-60). The procedure was performed without intraoperative adverse events or significant postoperative complications. The overall cure rate, significant improvement rate and failure rate were 28.6%, 35.7% and 35.7%.respectively, with a total of 64.3% considered as success (cured or significantly improved). At 1 year of follow-up, 71.4% of the patients (cured or improved) demonstrated persistence of the favourable outcome. Endoscopic treatment of post prostatectomy incontinence due sphinteric deficiency is a minimally invasive, safe and successful procedure. Endoscopic submucosal injection of dextranomer has shown a durable favorable outcome at 1 year of follow-up. (author)

  17. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: ursula.fittschen@chemie.uni-hamburg.de; Meirer, F. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: fmeirer@ati.ac.at; Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: wobi@ati.ac.at; Thiele, J. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: Julian.Thiele@gmx.de; Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: falkenbe@mail.desy.de; Pepponi, G. [ITC-irst, Via Sommarive 18, 38050 Povo (Trento) (Italy)], E-mail: pepponi@itc.it

    2008-12-15

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 {mu}m, 8.0-2.0 {mu}m, 2.0-0.13 {mu}m 0.13-0.015 {mu}m (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 {mu}m, 1-2 {mu}m, 2-4 {mu}m, 4-8 {mu}m, 8-16 {mu}m. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in

  18. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    International Nuclear Information System (INIS)

    Fittschen, U.E.A.; Meirer, F.; Streli, C.; Wobrauschek, P.; Thiele, J.; Falkenberg, G.; Pepponi, G.

    2008-01-01

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 μm, 8.0-2.0 μm, 2.0-0.13 μm 0.13-0.015 μm (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 μm, 1-2 μm, 2-4 μm, 4-8 μm, 8-16 μm. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in all particle size fractions

  19. Achieving Higher Accuracy in the Gamma-Ray Spectrocopic Assay of Holdup

    International Nuclear Information System (INIS)

    Russo, P.A.; Wenz, T.R.; Smith, S.E.; Harris, J.F.

    2000-01-01

    Gamma-ray spectroscopy is an important technique for the measurement of quantities of nuclear material holdup in processing equipment. Because the equipment in large facilities dedicated to uranium isotopic enrichment, uranium/plutonium scrap recovery or various stages of fuel fabrication is extensive, the total holdup may be large by its distribution alone, even if deposit thicknesses are small. Good accountability practices require unbiased measurements with uncertainties that are as small as possible. This paper describes new procedures for use with traditional holdup analysis methods based on gamma-ray spectroscopy. The procedures address the two sources of bias inherent in traditional gamma-ray measurements of holdup. Holdup measurements are performed with collimated, shielded gamma-ray detectors. The measurement distance is chosen to simplify the deposit geometry to that of a point, line or area. The quantitative holdup result is based on the net count rate of a representative gamma ray. This rate is corrected for contributions from room background and for attenuation by the process equipment. Traditional holdup measurements assume that the width of the point or line deposit is very small compared to the measurement distance, and that the self-attenuation effects can be neglected. Because each point or line deposit has a finite width and because self-attenuation affects all measurements, bias is incurred in both assumptions. In both cases the bias is negative, explaining the systematically low results of gamma-ray holdup measurements. The new procedures correct for bias that arises from both the finite-source effects and the gamma-ray self-attenuation. The procedures used to correct for both of these effects apply to the generalized geometries. One common empirical parameter is used for both corrections. It self-consistently limits the total error incurred (from uncertain knowledge of this parameter) in the combined correction process, so that it is

  20. 22 CFR 226.44 - Procurement procedures.

    Science.gov (United States)

    2010-04-01

    ... Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Procurement Standards § 226.44 Procurement procedures. (a... and assistance, as appropriate, of such organizations as the Small Business Administration and the...

  1. In vitro biofilm formation on resin-based composites after different finishing and polishing procedures.

    Science.gov (United States)

    Cazzaniga, Gloria; Ottobelli, Marco; Ionescu, Andrei C; Paolone, Gaetano; Gherlone, Enrico; Ferracane, Jack L; Brambilla, Eugenio

    2017-12-01

    To evaluate the influence of surface treatments of different resin-based composites (RBCs) on S. mutans biofilm formation. 4 RBCs (microhybrid, nanohybrid, nanofilled, bulk-filled) and 6 finishing-polishing (F/P) procedures (open-air light-curing, light-curing against Mylar strip, aluminum oxide discs, one-step rubber point, diamond bur, multi-blade carbide bur) were evaluated. Surface roughness (SR) (n=5/group), gloss (n=5/group), scanning electron microscopy morphological analysis (SEM), energy-dispersive X-ray spectrometry (EDS) (n=3/group), and S. mutans biofilm formation (n=16/group) were assessed. EDS analysis was repeated after the biofilm assay. A morphological evaluation of S. mutans biofilm was also performed using confocal laser-scanning microscopy (CLSM) (n=2/group). The data were analyzed using Wilcoxon (SR, gloss) and two-way ANOVA with Tukey as post-hoc tests (EDS, biofilm formation). F/P procedures as well as RBCs significantly influenced SR and gloss. While F/P procedures did not significantly influence S. mutans biofilm formation, a significant influence of RBCs on the same parameter was found. Different RBCs showed different surface elemental composition. Both F/P procedures and S. mutans biofilm formation significantly modified this parameter. The tested F/P procedures significantly influenced RBCs surface properties but did not significantly affect S. mutans biofilm formation. The significant influence of the different RBCs tested on S. mutans biofilm formation suggests that material characteristics and composition play a greater role than SR. F/P procedures of RBCs may unexpectedly play a minor role compared to that of the restoration material itself in bacterial colonization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Arterial embolization for treating post-transplanted renal failure

    International Nuclear Information System (INIS)

    Yang Xizhang; Yang Li; Chen Ziqian; Yang Yongyan

    2008-01-01

    Objective: To investigate the significance of renal arterial embolization nephrectomy for treating post-transplanted renal failure. Methods: 15 cases of post-transplanted renal failure received renal arterial embolization. The post-procedural efficacies were followed up for about 6 months to 4 years. Results: Among the 15 cases, 11 showed blood pressure decreasing to normal level, 3 with reduction of the drug dose for anti-hypertension and 1 of no response. In addition, 12 suffered from postprocedural anuria, and 3 with obvious hypourocrinia associated with significant decrease of proteinuia; 5 with positive lymphcytic population response antigen (PRA > 20%), but turning negative with 3 of them after 3 weeks. All the transplanted kidneys revealed different degrees of atrophy but 4 of them obtained chances of successful retransplantation 3- 6 months after the procedure, 3 of them with follow up of 1-3 years were being well. Conclusions: Renal arterial embolization is a safe, efficient measure for treating post-transplanted renal failure with obvious decrease of correlative clinical symptoms and providing conditions for renal retransplantation. (authors)

  3. X-ray examination apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Griswa, P.J.; Halter, P. Jr.; Kidd, H.J.

    1980-01-01

    Apparatus for x-ray cardiovascular examination and which can also be used for general purpose examination is described. An advantage of the system is that there is no mechanical connection between the image intensifier and source to interfere with the medical examiner or emergency procedures. (U.K.)

  4. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    International Nuclear Information System (INIS)

    Fernandez-Ruiz, R.; Garcia-Heras, M.

    2008-01-01

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies

  5. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion, Facultad de Ciencias, Universidad Autonoma de Madrid, Modulo C-9, Laboratorio de TXRF, Crta. Colmenar, Km 15, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Garcia-Heras, M. [Grupo de Arqueometria de Vidrios y Materiales Ceramicos, Instituto de Historia, Centro de Ciencias Humanas y Sociales, CSIC, C/ Albasanz, 26-28, 28037 Madrid (Spain)

    2008-09-15

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies.

  6. Popular Berkeley Lab X-ray Data Booklet reissued

    International Nuclear Information System (INIS)

    Robinson, Art

    2001-01-01

    X-ray scientists and synchrotron-radiation users who have been patiently waiting for an updated version of the popular X-Ray Data Booklet last published in 1986 by the Center for X-Ray Optics at the Lawrence Berkeley National Laboratory can breathe a sigh of relief. The venerable ''little orange book'' has now been reissued under the auspices of CXRO and the Advanced Light Source (ALS) with an April printing of 10,000 paper copies and the posting of a Web edition at http://xdb.lbl.gov

  7. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  8. [Post-operative infections after cosmetic tourism].

    Science.gov (United States)

    Holst-Albrechtsen, Sine; Sørensen, Lene Birk; Juel, Jacob

    2018-06-11

    Cosmetic tourism is defined as patient mobility across borders, typically constituted by patients seeking cosmetic surgery at lower costs abroad. The most common procedures are abdominoplasty, fat grafting and breast augmentation. Very little is known about the complication rates after cosmetic tourism, and there is a paucity of evidence in all aspects of cosmetic tourism. In this review, we focus on post-operative complications i.e. post-operative infections, in particular with rare microorganisms such as mycobacteria.

  9. Occupational radiation doses during interventional procedures

    International Nuclear Information System (INIS)

    Nuraeni, N; Hiswara, E; Kartikasari, D; Waris, A; Haryanto, F

    2016-01-01

    Digital subtraction angiography (DSA) is a type of fluoroscopy technique used in interventional radiology to clearly visualize blood vessels in a bony or dense soft tissue environment. The use of DSA procedures has been increased quite significantly in the Radiology departments in various cities in Indonesia. Various reports showed that both patients and medical staff received a noticeable radiation dose during the course of this procedure. A study had been carried out to measure these doses among interventionalist, nurse and radiographer. The results show that the interventionalist and the nurse, who stood quite close to the X-ray beams compared with the radiographer, received radiation higher than the others. The results also showed that the radiation dose received by medical staff were var depending upon the duration and their position against the X-ray beams. Compared tothe dose limits, however, the radiation dose received by all these three medical staff were still lower than the limits. (paper)

  10. Exposure from diagnostic nuclear medicine procedures

    International Nuclear Information System (INIS)

    Iacob, O.; Diaconescu, C.; Isac, R.

    2002-01-01

    According to our last national study on population exposures from natural and artificial sources of ionizing radiation, 16% of overall annual collective effective dose represent the contribution of diagnostic medical exposures. Of this value, 92% is due to diagnostic X-ray examinations and only 8% arise from diagnostic nuclear medicine procedures. This small contribution to collective dose is mainly the result of their lower frequency compared to that of the X-ray examinations, doses delivered to patients being, on average, ten times higher. The purpose of this review was to reassess the population exposure from in vivo diagnostic nuclear medicine procedures and to evaluate the temporal trends of diagnostic usage of radiopharmaceuticals in Romania. The current survey is the third one conducted in the last decade. As in the previous ones (1990 and 1995), the contribution of the Radiation Hygiene Laboratories Network of the Ministry of Health and Family in collecting data from nuclear medicine departments in hospitals was very important

  11. Acquisition and Post-Processing of Immunohistochemical Images.

    Science.gov (United States)

    Sedgewick, Jerry

    2017-01-01

    Augmentation of digital images is almost always a necessity in order to obtain a reproduction that matches the appearance of the original. However, that augmentation can mislead if it is done incorrectly and not within reasonable limits. When procedures are in place for insuring that originals are archived, and image manipulation steps reported, scientists not only follow good laboratory practices, but avoid ethical issues associated with post processing, and protect their labs from any future allegations of scientific misconduct. Also, when procedures are in place for correct acquisition of images, the extent of post processing is minimized or eliminated. These procedures include white balancing (for brightfield images), keeping tonal values within the dynamic range of the detector, frame averaging to eliminate noise (typically in fluorescence imaging), use of the highest bit depth when a choice is available, flatfield correction, and archiving of the image in a non-lossy format (not JPEG).When post-processing is necessary, the commonly used applications for correction include Photoshop, and ImageJ, but a free program (GIMP) can also be used. Corrections to images include scaling the bit depth to higher and lower ranges, removing color casts from brightfield images, setting brightness and contrast, reducing color noise, reducing "grainy" noise, conversion of pure colors to grayscale, conversion of grayscale to colors typically used in fluorescence imaging, correction of uneven illumination (flatfield correction), merging color images (fluorescence), and extending the depth of focus. These corrections are explained in step-by-step procedures in the chapter that follows.

  12. Survey on the frequency of typical X-Ray examinations and estimation of associated population doses in the Republic of Macedonia

    International Nuclear Information System (INIS)

    Gershan, V.; Stikova, E.

    2013-01-01

    Purpose: Medical X-ray exposures have been the largest man-made source of population exposure to ionizing radiation in developed countries for many years. It is therefore important for radiation protection and health care authorities in each country to regularly assess the magnitude and the distribution of this large and increasing source of population exposure. The purpose of this paper is to present results from the survey on the number of typical X-ray examination procedures in the Republic of Macedonia for 2010, the distribution of examination procedures by type per modality for adults and pediatric patients, the annual frequency per 1000 population and the collective effective dose per 1000 population from the X-ray examination procedures performed in the Republic of Macedonia in 2010. Materials and methods: In the beginning of 2011, a survey was initiated in the Republic of Macedonia for collecting data on the number of typical X-ray examination procedures conducted in 2010 as a basis for estimating frequency of these procedures and associated population doses. The survey was initiated within a Dose Data Med project launched by the European Commission to study population doses from medical exposures within the Union. The Republic of Macedonia was invited to participate in this project as a test country. Typical X-ray examination procedures encompass those that are recognized to be the most important for the total population dose, referred to as TOP20 X-ray procedures. The survey was based on a specific questionnaire being prepared and distributed to the 87 X-ray departments in the Republic of Macedonia intended to cover the data for the year of 2010. The data was collected and summarized. Based on data gathered, the total number of examination procedures, annual frequency and their distribution by modality were calculated. Thereafter, the annual collective effective dose per 1000 population for each examination procedure in the TOP20 group and collective

  13. Guidelines for radioelement mapping using gamma ray spectrometry data

    International Nuclear Information System (INIS)

    2003-07-01

    The purpose of the report is to provide an up-to-date review on the use of gamma ray spectrometry for radioelement mapping and, where appropriate, provide guidelines on the correct application of the method. It is a useful training guide for those new to the method. It gives a broad coverage of all aspects of the gamma ray method and provides a comprehensive list of references. The report gives an overview of the theoretical background to radioactivity and the gamma ray spectrometric method followed by a review of the application of the method to mapping the radiation environment. A brief outline is presented of the principles of radioactivity, the interaction of gamma rays with matter, instrumentation applied to the measurement of gamma rays, and the quantities and units in contemporary use in gamma ray spectrometry. This is followed by a review of the fundamentals of gamma ray spectrometry, and its application to ground and airborne mapping. Covered are also all aspects of the calibration and data processing procedures required for estimating the ground concentrations of the radioelements. The procedures required for the recovery of older survey data are also presented as well as an overview of data presentation and integration for mapping applications

  14. New intraoral x-ray fluorographic imaging for dentistry

    International Nuclear Information System (INIS)

    Higashi, T.; Osada, T.; Aoyama, W.; Iguchi, M.; Suzuki, S.; Kanno, M.; Moriya, K.; Yoshimura, M.; Tusuda, M.

    1983-01-01

    A new dental x-ray fluorographic unit has been developed. This unit is composed of small intraoral x-ray tube, a compact x-ray image intensifier, and a high-resolution TV system. The purposes for developing this equipment were to (1) directly observe the tooth during endodontic procedures and (2) reduce x-ray exposure to the patient and the dentist. The radiation exposure can be reduced to about 1/600 the exposure used with conventional dental film. In clinical trials, a satisfactory fluorographic dental image for endodontic treatment was obtained with this new device

  15. Development of real-time x-ray microtomography system

    International Nuclear Information System (INIS)

    Takano, H; Morikawa, M; Konishi, S; Azuma, H; Shimomura, S; Tsusaka, Y; Kagoshima, Y; Nakano, S; Kosaka, N; Yamamoto, K

    2013-01-01

    We have developed a four-dimensional (4D) x-ray microcomputed tomography (CT) system that can obtain time-lapse CT volumes in real time. The system consists of a high-speed sample rotation system and a high-frame-rate x-ray imager, which are installed at a synchrotron radiation x-ray beamline. As a result of system optimization and introduction of a 'zoom resolution' procedure, a real-time 4D CT movie with a frame rate of 30 was obtained with a voxel size of 2.5 μm using 10 keV x-rays

  16. Analysis of the procedures and criteria for implantation of X-ray beams for ISO 4037 reference at low energies

    International Nuclear Information System (INIS)

    Figueiredo, Marcus Tadeu Tanuri de

    2012-01-01

    According to the radiological protection principles, practices involving ionizing radiation must be planned and carried out under the guarantee that the values of individual doses, the number of people exposed to radiation and the probability of accidental exposures are as low as reasonably achievable. Therefore, radiation dosimetry is required to be done with reliable instruments designed for measuring dosimetric quantities. The reliability of the dosimetry depends on both the calibration of the dosimeter and its proper performance under certain test conditions. The International Standardization Organization (ISO), in order to promote international standardization and metrological coherency, established sets of reference X-ray beams for dosimeter calibration and typing-test; they are expected to be implemented in metrology laboratories in compliance with specific technical requirements. At low energies there are specific requirements that need to be considered in both the implementation of the reference beams and their use in calibration and testing. The present study is an analysis of the procedures and criteria for ISO 4037 reference radiation implementation, at low energies. In the Dosimeter Calibration Laboratory of the Development Center of Nuclear Technology (LCD / CDTN), experiments were performed for determining the X-ray reference radiation parameters. Alternatives to the usual methods for half-value layer determination were studied. Spectra of reference beams were simulated with software and compared with experimental measurements. Different climatic conditions were reproduced in the Laboratory for analysis of its influence on the determination of the beam parameters. Uncertainties in the measurements of studied parameters were evaluated. According to the ISO 4037 criteria, the low energy X-ray beams were considered to be implemented; they allowed the determination of the conversion coefficients from air kerma to the operational radiation protection

  17. Theory of X-ray absorption and emission spectra

    International Nuclear Information System (INIS)

    Mukoyama, Takeshi

    2004-01-01

    Theoretical studies on X-ray absorption and emission spectroscopy are discussed. Simple expressions for X-ray emission rate and X-ray absorption cross section are presented in the dipole approximation. Various atomic models to obtain realistic wave functions and theoretical calculations for X-ray absorption cross sections and X-ray emission rates are described. In the case of molecules and solids, molecular orbital methods for electronic structures and molecular wave functions are discussed. The emphasis is on the procedures to obtain the excited-state and continuum wave functions for molecules and to calculate the multi-center dipole matrix elements. The examples of the calculated X-ray absorption and emission spectra are shown and compared with the experimental results

  18. Dose levels in conventional X-rays

    International Nuclear Information System (INIS)

    Guerra M, J. A.; Gonzalez G, J. A.; Pinedo S, A.; Salas L, M. A.; Vega C, H. R.; Rivera M, T.; Azorin N, J.

    2009-10-01

    There were a series of measures in the General Hospital of Fresnillo in the X-ray Department in the areas of X-1 and X-2-ray rooms and in the neonatal intensive care unit 2, was determined the dose surface entry in eyes, thyroid and gonads for patients undergoing to X-ray study of chest Tele by thermoluminescent dosimetry. Five dosemeters were used in each one of the scans; so find the following dose ranges 20 + - 23 mGy to 350 + - 41 mGy. With the results obtained we can conclude that the procedures used and the equipment calibration is adequate. (Author)

  19. Streaked, x-ray-transmission-grating spectrometer

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Roth, M.; Hawryluk, A.M.

    1981-08-01

    A free standing x-ray transmission grating has been coupled with a soft x-ray streak camera to produce a time resolved x-ray spectrometer. The instrument has a temporal resolution of approx. 20 psec, is capable of covering a broad spectral range, 2 to 120 A, has high sensitivity, and is simple to use requiring no complex alignment procedure. In recent laser fusion experiments the spectrometer successfully recorded time resolved spectra over the range 10 to 120 A with a spectral resolving power, lambda/Δlambda of 4 to 50, limited primarily by source size and collimation effects

  20. Study of consumer fireworks post-blast residues by ATR-FTIR.

    Science.gov (United States)

    Martín-Alberca, Carlos; Zapata, Félix; Carrascosa, Héctor; Ortega-Ojeda, Fernando E; García-Ruiz, Carmen

    2016-03-01

    Specific analytical procedures are requested for the forensic analysis of pre- and post-blast consumer firework samples, which present significant challenges. Up to date, vibrational spectroscopic techniques such as Fourier transform infrared spectroscopy (FTIR) have not been tested for the analysis of post-blast residues in spite of their interesting strengths for the forensic field. Therefore, this work proposes a simple and fast procedure for the sampling and analysis of consumer firework post-blast residues by a portable FTIR instrument with an Attenuated Total Reflection (ATR) accessory. In addition, the post-blast residues spectra of several consumer fireworks were studied in order to achieve the identification of their original chemical compositions. Hence, this work analysed 22 standard reagents usually employed to make consumer fireworks, or because they are related to their combustion products. Then, 5 different consumer fireworks were exploded, and their residues were sampled with dry cotton swabs and directly analysed by ATR-FTIR. In addition, their pre-blast fuses and charges were also analysed in order to stablish a proper comparison. As a result, the identification of the original chemical compositions of the post-blast samples was obtained. Some of the compounds found were potassium chlorate, barium nitrate, potassium nitrate, potassium perchlorate or charcoal. An additional study involving chemometric tools found that the results might greatly depend on the swab head type used for the sampling, and its sampling efficiency. The proposed procedure could be used as a complementary technique for the analysis of consumer fireworks post-blast residues. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Post-ERCP acute pancreatitis and its risk factors.

    Science.gov (United States)

    Iorgulescu, A; Sandu, I; Turcu, F; Iordache, N

    2013-03-15

    Endoscopic retrograde cholangiopancreatography (ERCP) is a complex endoscopic technique that evolved from a diagnostic to a mainly therapeutic procedure. This was due to the identification of post-procedural complications that can follow both simple ERCP and that associated with the instrumentation of the biliary and pancreatic ductals. The identification of post ERCP complications in a proportion of 5 to 10% of cases, with a mortality rate of 0.33%, imposed their analysis and study of risk factors involved in their occurrence. The significance of post ERCP complications reveals the necessity of their avoidance by adopting additional measures if risk factors are identified. We have retrospectively analyzed 900 cases that underwent ERCP in the Surgery Department of "Sf. Ioan" Clinical Hospital in a period of 17 years. The complications of the procedure were studied. Among them, a special attention was given to post-ERCP acute pancreatitis (pERCP-AP), the most common complication that occurred in the study group. We also tried to find out and highlight the risk factors for this complication. ERCP is a relatively safe invasive procedure, yet it has complications (8% of cases), some of them potentially fatal (mortality 0.43%). The most common complications after ERCP are acute pancreatitis (3.7%), papillary bleeding (1.04%), retroperitoneal duodenal perforation (0.69%) and biliary septic complications like acute cholecystitis and cholangitis (1.21%). Acute pancreatitis is by far the most common complication. Risk factors for its occurrence are difficult sphincterotomy with precut use, failure of CBD desobstruction, pancreatic sphincterotomy, repeated injection of contrast in the pancreatic ductal system, dysfunction of the sphincter of Oddi and the absence of changes of chronic pancreatitis. When risk factors are identified, the patients' selection must be very strict and diagnostic ERCP should be avoided in favor of non-invasive diagnostic methods (MRI

  2. Adopting wedge hepatic venography with CO2 during transjugular intrahepatic portosystemic shunt procedures

    International Nuclear Information System (INIS)

    Zhang Linpeng; Chen Songtao; Shi Xiulan

    2012-01-01

    Objective: To renovate angiography in identifying portal vein anatomy during transjugular intrahepatic portosystemic shunt (TIPS) procedures, saving the time of TIPS procedures, decreasing the risk of the complications of the post-procedure. Methods: The difference between the Wedge hepatic venography with Carbon Dioxide in 6 cases and Inferior Mesenteric artery angiography in 7 cases during TIPS procedures were compared in the identification of portal vein anatomy. The quality of images, their effects on the procedures, the complications and the recovery post-procedure were evaluated. Results: Using CO 2 , the portal veins were opacified in all 6 cases. TIPS procedures succeeded in all cases except 1 case because of poor coagulation function. Using Inferior Mesenteric artery angiography, the portal veins were opacified in all 7 cases. TIPS procedure succeeded in all cases except 1 case because of chronic portal occlusion. Puncture-site hematoma occurred in 1 case after TIPS procedure. Conclusion: Wedge hepatic venography with Carbon Dioxide is superior, safer and more convenient than Inferior Mesenteric Artery angiography in identifying portal vein anatomy during TIPS. (authors)

  3. Prevention of post endoscopic retrograde cholangiopancreatography pancreatitis

    Directory of Open Access Journals (Sweden)

    Nalini M Guda

    2012-01-01

    Full Text Available Post ERCP pancreatitis (PEP is a common problem. Knowledge of patient and procedure related risk factors along with appropriate measures aimed at reduction of risk have been successful in reducing both the incidence and the severity. Prophylactic pancreatic duct stenting has definitely reduced the incidence and the severity of PEP in high risk patients. There are some emerging data on the use of non steroidal anti inflammatory agents though this is not widely adapted in practice. Key is to avoid procedures with marginal indications and use of non invasive/less invasive procedures.

  4. High post-capture survival for sharks, rays and chimaeras discarded in the main shark fishery of Australia?

    Science.gov (United States)

    Braccini, Matias; Van Rijn, Jay; Frick, Lorenz

    2012-01-01

    Most sharks, rays and chimaeras (chondrichthyans) taken in commercial fisheries are discarded (i.e. returned to the ocean either dead or alive). Quantifying the post-capture survival (PCS) of discarded species is therefore essential for the improved management and conservation of this group. For all chondrichthyans taken in the main shark fishery of Australia, we quantified the immediate PCS of individuals reaching the deck of commercial shark gillnet fishing vessels and applied a risk-based method to semi-quantitatively determine delayed and total PCS. Estimates of immediate, delayed and total PCS were consistent, being very high for the most commonly discarded species (Port Jackson shark, Australian swellshark, and spikey dogfish) and low for the most important commercial species (gummy and school sharks). Increasing gillnet soak time or water temperature significantly decreased PCS. Chondrichthyans with bottom-dwelling habits had the highest PCS whereas those with pelagic habits had the lowest PCS. The risk-based approach can be easily implemented as a standard practice of on-board observing programs, providing a convenient first-step assessment of the PCS of all species taken in commercial fisheries.

  5. A procedure for routine radiation protection checking of mammography equipment

    International Nuclear Information System (INIS)

    Bengtsson, L.G.; Lundehn, I.

    1980-01-01

    A procedure was developed for checking of mammography equipment used in screening for mammary cancer. The procedure will be handled by hospital physicists or x-ray inspectors and is intended to permit checking of x-ray equipment performance as well as evaluation of mean dose or eneray imparted to groups of patients. Measurement methods studied involve TLD, ionization chambers and a new plastic scintillator designed to measure energy imparted. After careful study of sizes and attenuation properties of breasts, a 50 mm polymethylmetacrylate phantom seemed the most appropriate. The choice of measuring equipment is reported as well as some preliminary results from field measurements. (author)

  6. Examination procedure for making an X-ray of one layer of an object (body)

    International Nuclear Information System (INIS)

    1977-01-01

    The paper describes experimental equipment with a radiation source such as gamma or X-ray radiation sources, and a radiation detector, which are mechanically coupled with one another. This setup is used for making an X-ray image of one layer of the body. (G.C.)

  7. Development of a novel micro pattern gaseous detector for cosmic ray muon tomography

    Energy Technology Data Exchange (ETDEWEB)

    Biglietti, M. [INFN Sezione di Roma Tre, Rome (Italy); Canale, V. [Università di Napoli Federico II, Naples (Italy); INFN Sezione di Napoli, Naples (Italy); Franchino, S. [CERN, Geneva (Switzerland); Iengo, P. [INFN Sezione di Napoli, Naples (Italy); CERN, Geneva (Switzerland); Iodice, M. [INFN Sezione di Roma Tre, Rome (Italy); Petrucci, F., E-mail: petrucci@roma3.infn.it [INFN Sezione di Roma Tre, Rome (Italy); Università Roma Tre, Rome (Italy)

    2016-07-11

    We propose a novel detector (Thick Groove Detector, TGD) designed for cosmic ray tomography with a spatial resolution of ~500 μm, trying to keep the construction procedure as simple as possible and to reduce the operating costs. The TGD belongs to the category of MPGDs with an amplification region less than 1 mm wide formed by alternate anode/cathode microstrips layers at different heights. A first 10×10 cm{sup 2} prototype has been built, divided in four sections with different test geometries. We present the construction procedure and the first results in terms of gain and stability. Preliminary studies with cosmic rays are also reported. - Highlights: • A new MPGD detector designed for cosmic ray tomography is presented. • With respect to existing detectors, the construction procedure is simpler and operating costs are lower. • Construction procedures and preliminary performance are shown.

  8. Phase-contrast tomographic imaging using an X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Momose, A. [Hitachi Ltd, Advanced Research Lab., Saitama (Japan); Takeda, T.; Itai, Y. [Univ. of Tsukuba, Inst. of Clinical Medicine, Ibaraki (Japan); Yoneyama, A. [Hitachi Ltd, Central Resarch Lab., Tokyo (Japan); Hirano, K. [High Energy Accelerator Research Organization, Inst. of Materials Structure Science, Ibaraki (Japan)

    1998-05-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays. 35 refs.

  9. Phase-contrast tomographic imaging using an X-ray interferometer

    International Nuclear Information System (INIS)

    Momose, A.; Takeda, T.; Itai, Y.; Yoneyama, A.; Hirano, K.

    1998-01-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays

  10. X-ray and gamma-ray standards for detector calibration

    International Nuclear Information System (INIS)

    1991-09-01

    The IAEA established a Co-ordinated Research Programme (CRP) on the Measurements and Evaluation of X- and Gamma-Ray Standards for Detector Efficiency Calibration in 1986 with the aim of alleviating the generation of such discrepancies. Within the framework of this CRP, representatives of nine research groups from six Member States and one international organization performed a number of precise measurements and systematic in-depth evaluations of the required decay data. They have also contributed to the development of evaluation methodology and measurement techniques, and stimulated a number of such studies at laboratories not directly involved in the IAEA project. The results of the work of the CRP, which was finished in 1990, are presented in this report. Recommended values of half-lives and photon emission probabilities are given for a carefully selected set of radionuclides that are suitable for detector efficiency calibration (X-rays from 5 to 90 keV and gamma-rays from 30 to about 3000 keV). Detector efficiency calibration for higher gamma-ray energies (up to 14 MeV) is also considered. The evaluation procedures used to obtain the recommended values and their estimated uncertainties are reported, and a summary of the remaining discrepancies is given. Refs and tabs

  11. Post-vasectomy depression: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Subahani Shaik

    2014-09-01

    Full Text Available Vasectomy is a commonly performed and relatively safe procedure, with low reported rates of psychological morbidity, though there is some variability across studies. Depression following a vasectomy is relatively infrequent. A married man aged 30 developed a chronic depressive episode, lasting four years and resistant to an adequate trial of fluoxetine, following a vasectomy. His depression was heralded by a post-operative panic attack, and was accompanied by medically unexplained symptoms and the attribution of all his symptoms to the procedure – a belief that was shared by his family. Psychological complications of vasectomy have generally been studied under four heads: sexual dysfunction, effects on marital relationships, chronic post-operative pain, and other complications including anxiety and depression. These complications have generally been reported at higher rates in developing countries, and are linked to poor knowledge about the procedure and inadequate pre-operative counseling. The implications of the existing literature for the patient’s current complaints, and the mechanisms and risk factors involved, are discussed in the light of existing research. Suggestions for the prevention and treatment of post-vasectomy depression are also outlined.

  12. 32 CFR Appendix to Part 162 - Reporting Procedures

    Science.gov (United States)

    2010-07-01

    ... ENHANCING CAPITAL INVESTMENT (PECI) Pt. 162, App. A Appendix to Part 162—Reporting Procedures A. General The.... Total Projected Life-Cycle Cost Avoidance. 4. PIA Post-Investment assessments, articles, pictures, and...

  13. Recurred Post-intubation Tracheal Stenosis Treated with Bronchoscopic Cryotherapy

    Science.gov (United States)

    Jung, Ye-Ryung; Taek Jeong, Joon; Kyu Lee, Myoung; Kim, Sang-Ha; Joong Yong, Suk; Jeong Lee, Seok; Lee, Won-Yeon

    2016-01-01

    Post-intubation tracheal stenosis accounts for the greatest proportion of whole-cause tracheal stenosis. Treatment of post-intubation tracheal stenosis requires a multidisciplinary approach. Surgery or an endoscopic procedure can be used, depending on the type of stenosis. However, the efficacy of cryotherapy in post-intubation tracheal stenosis has not been validated. Here, we report a case of recurring post-intubation tracheal stenosis successfully treated with bronchoscopic cryotherapy that had previously been treated with surgery. In this case, cryotherapy was effective in treating web-like fibrous stenosis, without requiring more surgery. Cryotherapy can be considered as an alternative or primary treatment for post-intubation tracheal stenosis. PMID:27853078

  14. A low power x-ray tube for use in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kataria, S.K.; Govil, Rekha; Lal, M.

    1980-01-01

    A low power X-ray tube with thin molybdenum transmission target for use in energy dispersive X-ray fluorescence (ENDXRF) element analysis has been indigenously built, along with its power supply. The X-ray tube has been in operation since August 1979, and it has been operated upto maximum target voltage of 35 KV and tube current upto 200 μA which is more than sufficient for trace element analysis. This X-ray tube has been used alongwith the indigenously built Si(Li) detector X-ray spectrometer with an energy resolution of 200 eV at 5.9 Kev MnKsub(α) X-ray peak for ENDXRF analysis. A simple procedure of calibration has been developed for thin samples based on the cellulose diluted, thin multielement standard pellets. Analytical sensitivities of the order of a few p.p.m. have been obtained with the experimental setup for elements with 20 < = Z < = 38 and 60 < = Z < = 90. A number of X-ray spectra for samples of environmental, biological, agricultural, industrial and metallurgical interest are presented to demonstrate the salient features of the experimental sep up. (auth.)

  15. Alpha Particle Induced X-ray Emission in the Classroom

    International Nuclear Information System (INIS)

    Lopez, Jorge A.; Borunda, Mario F.; Morales, Jaime

    2003-01-01

    We report on an experimental demonstration in an introductory modern physics course to elucidate the X-ray line spectra, and how they arise from transitions of electrons to inner shells. We seek to determine the effect of limited use of an interactive component as a supplement to a traditional lecture, and how it would improve the student achievement. In this preliminary study the students were exposed to traditional lectures on X-ray production and Bohr's model, they then were given a homework on the abc of X-ray spectra, after which they were given a pre-test on the materials, followed by an in-class demonstration, and a final post-exam. The gain, as measured from pre- to post-exams appears to remark the differences in how students approached the subject before and after the use of the demonstration. This initial study shows the validity of in-class demonstrations as teaching tools and opens a wide new area of research in modern physics teaching

  16. Determination of entrance skin dose from diagnostic X-ray of human ...

    African Journals Online (AJOL)

    patient during x-ray examination in Federal Medical Centre, Keffi in Nasarawa state, Nigeria. Entrance skin doses (ESDs) for a common type of x-ray procedures, namely chest AP/PA (anterior/posterior) were measured. A total of 200 data were collected from patients who were exposed to diagnostic X-ray during their routine ...

  17. A new procedure for static RAM evaluation under x-ray pulses

    International Nuclear Information System (INIS)

    Marec, R.; Gaillard, R.; Mary, P.; Fairbank, X.; Ferrant, R.; Palau, J.M.; Gasiot, J.

    1994-01-01

    An original method, to identify the initial patterns that are the most favorable to obtain upsets under X-ray pulses, has been developed on Static RAMs in the standby mode. The results obtained with these initial patterns are interesting in order to analyze the radiation induced failures

  18. X-ray diagnosis in temporal bone anomalies

    International Nuclear Information System (INIS)

    Schratter, M.; Canigiani, G.; Swoboda, H.; Brunner, E.

    1988-01-01

    The X-ray findings in temporal bone anomalies are reviewed. Radiological procedure and examination technique are presented, as are symptoms of important anomalies. The methods available are plain film X-ray of temporal bone, multi-directional tomography, and high-resolution CT. Although some of the abnormalities are visible even in plain films, consistent use of conventional tomography or CT is necessary for correct diagnosis. This procedure is indicated not only when an abnormality is clinically obvious, but also in all cases of unexplained hearing loss without evidence of acquired disease. The advantage of CT over conventional tomography is that soft tissue anomalies, such as primary cholesteatoma or tumor simulating vascular abnormalities, can be demonstrated. In these cases CT is obligatory. (orig.) [de

  19. X-ray hazards - diagnostic and therapeutic

    International Nuclear Information System (INIS)

    Putney, R.G.; Garvie, N.W.

    1985-01-01

    The subject is covered in sections, entitled: introduction; nature of X-rays; X-rays - effect on biological materials; X-ray measurement; radiation dosages to exposed groups; organizational structure of radiological protection; duties of the Radiological Safety Officer; general measures for radiological protection; protection of staff; protection of patients; safety measures in radiotherapy work - sealed sources laboratory -general safety rules; radiotherapy - duties of the Radiological Safety Officer (Radiotherapy); the custodian of sealed sources -duties and relevant radiological protection information; external beam therapy - radionuclide source unit - emergency procedure in the event of technical failure; safety aspects of brachytherapy in the patient's vicinity; diagnostic radiology; conclusion. (U.K.)

  20. 77 FR 2099 - Post Office Closing

    Science.gov (United States)

    2012-01-13

    ...This document informs the public that an appeal of the closing of the Hope, Minnesota post office has been filed. It identifies preliminary steps and provides a procedural schedule. Publication of this document will allow the Postal Service, petitioners, and others to take appropriate action.

  1. X-ray radiography of abdominal emergencies in clinical diagnosis

    International Nuclear Information System (INIS)

    Bencur, J.M.; Svoboda, M.

    1987-01-01

    The book explains in detail the procedure in X-ray examination and how to get the maximum of diagnostic information out of it. Part one is devoted to the organization, technology and methodology of X-ray examinations, the equipment of X-ray units and to radiation protection. Part two presents the anatomy of the abdomen and of the thorax, and the pathological manifestations of emergencies in the X-ray picture. Part three presents an analysis of the individual types of diseases and injuries illustrated with many pictures. (M.D.). 96 figs., 7 tabs., 400 refs

  2. Reversal of Hartmann's procedure following acute diverticulitis: is timing everything?

    LENUS (Irish Health Repository)

    Fleming, Fergal J

    2012-02-01

    BACKGROUND: Patients who undergo a Hartmann\\'s procedure may not be offered a reversal due to concerns over the morbidity of the second procedure. The aims of this study were to examine the morbidity post reversal of Hartmann\\'s procedure. METHODS: Patients who underwent a Hartmann\\'s procedure for acute diverticulitis (Hinchey 3 or 4) between 1995 and 2006 were studied. Clinical factors including patient comorbidities were analysed to elucidate what preoperative factors were associated with complications following reversal of Hartmann\\'s procedure. RESULTS: One hundred and ten patients were included. Median age was 70 years and 56% of the cohort were male (n = 61). The mortality and morbidity rate for the acute presentation was 7.3% (n = 8) and 34% (n = 37) respectively. Seventy six patients (69%) underwent a reversal at a median of 7 months (range 3-22 months) post-Hartmann\\'s procedure. The complication rate in the reversal group was 25% (n = 18). A history of current smoking (p = 0.004), increasing time to reversal (p = 0.04) and low preoperative albumin (p = 0.003) were all associated with complications following reversal. CONCLUSIONS: Reversal of Hartmann\\'s procedure can be offered to appropriately selected patients though with a significant (25%) morbidity rate. The identification of potential modifiable factors such as current smoking, prolonged time to reversal and low preoperative albumin may allow optimisation of such patients preoperatively.

  3. Radiation doses to patients in haemodynamic procedures

    International Nuclear Information System (INIS)

    Canadillas-Perdomo, B.; Catalan-Acosta, A.; Hernandez-Armas, J.; Perez-Martin, C.; Armas-Trujillo, D. de

    2001-01-01

    Interventional radio-cardiology gives high doses to patients due to high values of fluoroscopy times and large series of radiographic images. The main objective of the present work is the determination of de dose-area product (DAP) in patients of three different types of cardiology procedures with X-rays. The effective doses were estimated trough the organ doses values measured with thermoluminescent dosimeters (TLDs-100), suitable calibrated, placed in a phantom type Rando which was submitted to the same radiological conditions corresponding to the procedures made on patients. The values for the effective doses in the procedures CAD Seldinger was 6.20 mSv on average and 1.85mSv for pacemaker implants. (author)

  4. Radiation doses to patients in haemodynamic procedures

    Energy Technology Data Exchange (ETDEWEB)

    Canadillas-Perdomo, B; Catalan-Acosta, A; Hernandez-Armas, J [Servicio de Fisica Medica, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain); Perez-Martin, C [Servicio de Ingenieria Biomedica, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain); Armas-Trujillo, D de [Servicio de Cardiologia, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain)

    2001-03-01

    Interventional radio-cardiology gives high doses to patients due to high values of fluoroscopy times and large series of radiographic images. The main objective of the present work is the determination of de dose-area product (DAP) in patients of three different types of cardiology procedures with X-rays. The effective doses were estimated trough the organ doses values measured with thermoluminescent dosimeters (TLDs-100), suitable calibrated, placed in a phantom type Rando which was submitted to the same radiological conditions corresponding to the procedures made on patients. The values for the effective doses in the procedures CAD Seldinger was 6.20 mSv on average and 1.85mSv for pacemaker implants. (author)

  5. X-ray sources in regions of star formation. I. The naked T Tauri stars

    International Nuclear Information System (INIS)

    Walter, F.M.

    1986-01-01

    Einstein X-ray observations of regions of active star formation in Taurus, Ophiuchus, and Corona Australis show a greatly enhanced surface density of stellar X-ray sources over that seen in other parts of the sky. Many of the X-ray sources are identified with low-mass, pre-main-sequence stars which are not classical T Tauri stars. The X-ray, photometric, and spectroscopic data for these stars are discussed. Seven early K stars in Oph and CrA are likely to be 1-solar-mass post-T Tauri stars with ages of 10-million yr. The late K stars in Taurus are not post-T Tauri, but naked T Tauri stars, which are coeval with the T Tauri stars, differing mainly in the lack of a circumstellar envelope. 72 references

  6. Analysis of risk in computerized tomography and other diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Mossman, K.L.

    1982-01-01

    Medical practice entails continuous risks to the patient taken in good faith by the physician for the benefit of the patient. Risk of radiation induced cancer death approximates 10(-4) per cGy (rad). Assuming an average whole body dose of 0.1 cGy for many diagnostic X-ray procedures, the probability of radiation-induced cancer death is about 10(-5). The purpose of this paper is to compare the risks of common diagnostic X-ray procedures including computerized tomography (CT) with risks of smoking or automobile travel. Such comparisons should be constructive in putting radiation in perspective and facilitating explanation of risk/benefit to patients

  7. Surface slope metrology of highly curved x-ray optics with an interferometric microscope

    Science.gov (United States)

    Gevorkyan, Gevork S.; Centers, Gary; Polonska, Kateryna S.; Nikitin, Sergey M.; Lacey, Ian; Yashchuk, Valeriy V.

    2017-09-01

    The development of deterministic polishing techniques has given rise to vendors that manufacture high quality threedimensional x-ray optics. The surface metrology on these optics remains a difficult task. For the fabrication, vendors usually use unique surface metrology tools, generally developed on site, that are not available in the optical metrology labs at x-ray facilities. At the Advanced Light Source X-Ray Optics Laboratory, we have developed a rather straightforward interferometric-microscopy-based procedure capable of sub microradian characterization of sagittal slope variation of x-ray optics for two-dimensionally focusing and collimating (such as ellipsoids, paraboloids, etc.). In the paper, we provide the mathematical foundation of the procedure and describe the related instrument calibration. We also present analytical expression describing the ideal surface shape in the sagittal direction of a spheroid specified by the conjugate parameters of the optic's beamline application. The expression is useful when analyzing data obtained with such optics. The high efficiency of the developed measurement and data analysis procedures is demonstrated in results of measurements with a number of x-ray optics with sagittal radius of curvature between 56 mm and 480 mm. We also discuss potential areas of further improvement.

  8. High Post-Capture Survival for Sharks, Rays and Chimaeras Discarded in the Main Shark Fishery of Australia?

    Science.gov (United States)

    Braccini, Matias; Van Rijn, Jay; Frick, Lorenz

    2012-01-01

    Most sharks, rays and chimaeras (chondrichthyans) taken in commercial fisheries are discarded (i.e. returned to the ocean either dead or alive). Quantifying the post-capture survival (PCS) of discarded species is therefore essential for the improved management and conservation of this group. For all chondrichthyans taken in the main shark fishery of Australia, we quantified the immediate PCS of individuals reaching the deck of commercial shark gillnet fishing vessels and applied a risk-based method to semi-quantitatively determine delayed and total PCS. Estimates of immediate, delayed and total PCS were consistent, being very high for the most commonly discarded species (Port Jackson shark, Australian swellshark, and spikey dogfish) and low for the most important commercial species (gummy and school sharks). Increasing gillnet soak time or water temperature significantly decreased PCS. Chondrichthyans with bottom-dwelling habits had the highest PCS whereas those with pelagic habits had the lowest PCS. The risk-based approach can be easily implemented as a standard practice of on-board observing programs, providing a convenient first-step assessment of the PCS of all species taken in commercial fisheries. PMID:22384270

  9. Prehospital fast track care for patients with hip fracture: Impact on time to surgery, hospital stay, post-operative complications and mortality a randomised, controlled trial.

    Science.gov (United States)

    Larsson, Glenn; Strömberg, Rn Ulf; Rogmark, Cecilia; Nilsdotter, Anna

    2016-04-01

    Ambulance organisations in Sweden have introduced prehospital fast track care (PFTC) for patients with suspected hip fracture. This means that the ambulance nurse starts the pre-operative procedure otherwise implemented at the accident & emergency ward (A&E) and transports the patient directly to the radiology department instead of A&E. If the diagnosis is confirmed, the patient is transported directly to the orthopaedic ward. No previous randomised, controlled studies have analysed PFTC to describe its possible advantages. The aim of this study is to examine whether PFTC has any impact on outcomes such as time to surgery, length of stay, post-operative complications and mortality. The design of this study is a prehospital randomised, controlled study, powered to include 400 patients. The patients were randomised into PFTC or the traditional care pathway (A&E group). Time from arrival to start for X-ray was faster for PFTC (mean, 28 vs. 145 min; pstart of X-ray to start of surgery (mean 18.40 h in both groups). No significant differences between the groups were observed with regard to: time from arrival to start of surgery (p=0.07); proportion operated within 24h (79% PFTC, 75% A&E; p=0.34); length of stay (p=0.34); post-operative complications (p=0.75); and 4 month mortality (18% PFTC, 15% A&E p=0.58). PFTC improved time to X-ray and admission to a ward, as expected, but did not significantly affect time to start of surgery, length of stay, post-operative complications or mortality. These outcomes were probably affected by other factors at the hospital. Patients with either possible life-threatening conditions or life-threatening conditions prehospital were excluded. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Evaluation of an automated assay system to measure soil radionuclides by L x-ray and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Nyhan, J.W.; Drennon, B.J.; Crowell, J.M.

    1982-08-01

    An automated radionuclide assay system for conducting soil radioassays using L x-ray and gamma-ray spectrometry was evaluated. Wet chemistry assay procedures were shown to be considerably more time consuming than similar analyses of soil on this radionuclide assay system. The detection limits of 241 Am and plutonium were determined, as well as the reproducibility of radionuclide assay results. The L x-ray spectrometric measurements were compared with radiochemical analyses on several tuff samples. The assay system's intrinsic germanium detector was found to respond linearly to varying low concentrations of 241 Am and plutonium, both of which were easily detected in the presence of elevated concentrations of 137 Cs

  11. Testing of x-ray microtomography systems using a traceable geometrical standard

    International Nuclear Information System (INIS)

    Carmignato, S; Dreossi, D; Mancini, L; Tromba, G; Marinello, F; Savio, E

    2009-01-01

    X-ray computed microtomography is an interesting imaging technique for many applications, and is also very promising in the field of coordinate metrology at the micro scale. The main advantage with respect to traditional tactile-probing or optical coordinate measurement systems is that x-ray tomography can acquire dimensional and geometrical data for both inner and outer surfaces, without accessibility restrictions. However, there are no accepted test procedures available so far and measurement uncertainty is unknown in many cases, due to complex and numerous error sources. The paper presents the first results of a test procedure implemented for determining the errors of indication for length measurements of x-ray microtomography systems, using a new reference standard featuring a regular array of inner and outer cylindrical shapes. The developed test method allows the determination of specific characteristics of x-ray microtomography systems and can be used for the correction of systematic errors

  12. X-ray spectral determination by detection of radiation scattered at different angles

    International Nuclear Information System (INIS)

    Barrea, Raul; Mainardi, R.T.

    1987-01-01

    A precise knowledge of the spectral content of an X-ray beam is of fundamental importance in areas such as X-ray fluorescence analysis by absolute methods, radiodiagnosis, radiotherapy, computed tomography, etc. A simple practical method was developed to determine X-ray spectra emitted by X-ray tubes. It is based on the scattering of the beam on a solid target and detection of this radiation at different angles. This methodology can easily be adapted to the successive attenuation of the beam procedure. Numerical parameter values of a proposed analytical function for the energy spectrum are found measuring the radiation intensity with a suitable detector (ionization chamber or plastic scintillation detector) and equating it with the convolution integral of the proposed spectrum with the incoherent scattering function. This procedure of spectra determination is enclosed in the same group of those generically referred as successive modifications of the irradiation set up used in absolute methods of X-ray fluorescence analysis. (Author) [es

  13. Residual stress characterization of welds using x-ray diffraction techniques

    International Nuclear Information System (INIS)

    Pineault, J.A.; Brauss, M.E.

    1996-01-01

    Neglect of residual stresses created during processes lead to stress corrosion cracking, distortion, fatigue cracking, premature failures in components, and instances of over design. Automated residual stress mapping and truly portable equipment have now made the characterization of residual stresses using x-ray diffraction (XRI) practical. The nondestructive nature of the x-ray diffraction technique has made the tile residual stress characterization of welds a useful tool for process optimization and failure analysis, particularly since components can be measured before and after welding and post welding processes. This paper illustrates the importance of residual stress characterization in welds and presents examples where x-ray diffraction techniques were applied in the characterization of various kinds of welds. arc welds, TIG welds, resistance welds, laser welds and electron beam welds. Numerous techniques are available to help manage potentially harmfull residual stresses created during the welding process thus, the effects of a few example post weld processes such as grinding, heat treating and shot peening are also addressed

  14. Investigative procedures in thyroid cancer

    International Nuclear Information System (INIS)

    Samuel, A.M.

    1999-01-01

    One of the main objectives of the procedures is to establish the likelihood of malignancy in the thyroid gland prior to surgery and detect metastases after surgery. Thyroid imaging is discussed in the context of (a) its role in the diagnosis of the primary disease (b) in the investigation of post-operative residual disease and (c) its role in the follow-up of patients after radioiodine therapy

  15. Selective Embolization for Post-Endoscopic Sphincterotomy Bleeding: Technical Aspects and Clinical Efficacy

    Energy Technology Data Exchange (ETDEWEB)

    So, Young Ho; Choi, Young Ho [Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Chung, Jin Wook; Jae, Hwan Jun; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of); Song, Soon Young [Hanyang University Hospital, Seoul (Korea, Republic of)

    2012-01-15

    The objective of this study was to evaluate the technical aspects and clinical efficacy of selective embolization for post-endoscopic sphincterotomy bleeding. We reviewed the records of 10 patients (3%; M:F 6:4; mean age, 63.3 years) that underwent selective embolization for post-endoscopic sphincterotomy bleeding among 344 patients who received arteriography for nonvariceal upper gastrointestinal bleeding from 2000 to 2009. We analyzed the endoscopic procedure, onset of bleeding, underlying clinical condition, angiographic findings, interventional procedure, and outcomes in these patients. Among the 12 bleeding branches, primary success of hemostasis was achieved in 10 bleeding branches (83%). Secondary success occurred in two additional bleeding branches (100%) after repeated embolization. In 10 patients, post-endoscopic sphincterotomy bleedings were detected during the endoscopic procedure (n = 2, 20%) or later (n = 8, 80%), and the delay was from one to eight days (mean, 2.9 days; {+-} 2.3). Coagulopathy was observed in three patients. Eight patients had a single bleeding branch, whereas two patients had two branches. On the selective arteriography, bleeding branches originated from the posterior pancreaticoduodenal artery (n = 8, 67%) and anterior pancreaticoduodenal artery (n = 4, 33%), respectively. Superselection was achieved in four branches and the embolization was performed with n-butyl cyanoacrylate. The eight branches were embolized by combined use of coil, n-butyl cyanoacrylate, or Gelfoam. After the last embolization, there was no rebleeding or complication related to embolization. Selective embolization is technically feasible and an effective procedure for post-endoscopic sphincterotomy bleeding. In addition, the posterior pancreaticoduodenal artery is the main origin of the causative vessels of post-endoscopic sphincterotomy bleeding.

  16. Selective Embolization for Post-Endoscopic Sphincterotomy Bleeding: Technical Aspects and Clinical Efficacy

    International Nuclear Information System (INIS)

    So, Young Ho; Choi, Young Ho; Chung, Jin Wook; Jae, Hwan Jun; Park, Jae Hyung; Song, Soon Young

    2012-01-01

    The objective of this study was to evaluate the technical aspects and clinical efficacy of selective embolization for post-endoscopic sphincterotomy bleeding. We reviewed the records of 10 patients (3%; M:F 6:4; mean age, 63.3 years) that underwent selective embolization for post-endoscopic sphincterotomy bleeding among 344 patients who received arteriography for nonvariceal upper gastrointestinal bleeding from 2000 to 2009. We analyzed the endoscopic procedure, onset of bleeding, underlying clinical condition, angiographic findings, interventional procedure, and outcomes in these patients. Among the 12 bleeding branches, primary success of hemostasis was achieved in 10 bleeding branches (83%). Secondary success occurred in two additional bleeding branches (100%) after repeated embolization. In 10 patients, post-endoscopic sphincterotomy bleedings were detected during the endoscopic procedure (n = 2, 20%) or later (n = 8, 80%), and the delay was from one to eight days (mean, 2.9 days; ± 2.3). Coagulopathy was observed in three patients. Eight patients had a single bleeding branch, whereas two patients had two branches. On the selective arteriography, bleeding branches originated from the posterior pancreaticoduodenal artery (n = 8, 67%) and anterior pancreaticoduodenal artery (n = 4, 33%), respectively. Superselection was achieved in four branches and the embolization was performed with n-butyl cyanoacrylate. The eight branches were embolized by combined use of coil, n-butyl cyanoacrylate, or Gelfoam. After the last embolization, there was no rebleeding or complication related to embolization. Selective embolization is technically feasible and an effective procedure for post-endoscopic sphincterotomy bleeding. In addition, the posterior pancreaticoduodenal artery is the main origin of the causative vessels of post-endoscopic sphincterotomy bleeding.

  17. Patient doses from fluoroscopically guided cardiac procedures in pediatrics

    International Nuclear Information System (INIS)

    Martinez, L C; Vano, E; Gutierrez, F; Rodriguez, C; Gilarranz, R; Manzanas, M J

    2007-01-01

    Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for 2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers

  18. Medical staff radiation exposure in electrophysiology procedures: First results during biventricular ICD implantation

    International Nuclear Information System (INIS)

    Rossi, Pier Luca; Bianchini, David; Corazza, Ivan; Compagnone, Gaetano; Ferrari, Paolo; Gualdrini, Gianfranco; Zannoli, Romano

    2011-01-01

    Cardiac resynchronization therapy (CRT) requires a very long fluoroscopy time due to the need to monitor the placement of the device and electrodes inside the patient’s body at every step of the procedure. Aim of this study was to analyse staff X-ray exposure during the intervention, measuring H p (10) values with electronic dosimeters worn by medical staff. The scattered X-ray field was characterized using a spectrometric CdTe (cadmium-telluride) detector to define the radiation field impinging on the operator and thereby identify the correct dosimeter position for accurate measurement (i.e., above or under the shielding apron). In particular, knowledge of the X-ray spectrum yields information on photon flux and the energy distribution of the X-rays. Dosimetric data were then recorded in a series of 20 consecutive patients, obtaining a first set of H p (10) data that can be used to estimate the risk for the electrophysiologist performing this procedure.

  19. Bio-reconstruction of root canal using dentin post

    Directory of Open Access Journals (Sweden)

    Navin Mishra

    2013-01-01

    Full Text Available This case report describes the successful management of complicated crown fracture of left maxillary central incisor (#21 of 23-year-old male using dentin (biological post made from human tooth. Endodontic treatment was initiated and sectional obturation was done using ProTaper gutta-percha and AH Plus sealer. The coronal space was modified to receive a human dentin post. A two-step procedure comprising direct and indirect technique of post fabrication was done to achieve the accuracy of biological post. A maxillary cuspid from an institutional tooth bank was taken, sectioned mesiodistally using a diamond disc simulating the length and thickness of mock post. Dentin post was first verified on the plaster model and then cemented in tooth #21. Core build up was done with composite and porcelain fused to metal (PFM crown was luted. On the follow-up visits, patient was asymptomatic and radiographic evaluation revealed normal periradicular architecture. Biological posts may be good alternatives to conventional post systems as they preserve internal dentin walls, provide excellent adhesion, and resilience similar to natural tooth structure.

  20. Eye bank procedures: donor selection criteria.

    Science.gov (United States)

    Sousa, Sidney Júlio de Faria E; Sousa, Stella Barretto de Faria E

    2018-01-01

    Eye banks use sterile procedures to manipulate the eye, antiseptic measures for ocular surface decontamination, and rigorous criteria for donor selection to minimize the possibility of disease transmission due to corneal grafting. Donor selection focuses on analysis of medical records and specific post-mortem serological tests. To guide and standardize procedures, eye bank associations and government agencies provide lists of absolute and relative contraindications for use of the tissue based on donor health history. These lists are guardians of the Hippocratic principle "primum non nocere." However, each transplantation carries risk of transmission of potentially harmful agents to the recipient. The aim of the procedures is not to eliminate risk, but limit it to a reasonable level. The balance between safety and corneal availability needs to be maintained by exercising prudence without disproportionate rigor.

  1. Ghost imaging with paired x-ray photons

    Science.gov (United States)

    Schori, A.; Borodin, D.; Tamasaku, K.; Shwartz, S.

    2018-06-01

    We report the experimental observation of ghost imaging with paired x-ray photons, which are generated by parametric downconversion. We use the one-to-one relation between the photon energies and the emission angles and the anticorrelation between the k -vectors of the signal and the idler photons to reconstruct the images of slits with nominally zero background levels. Further extension of our procedure can be used for the observation of various quantum phenomena at x-ray wavelengths.

  2. The expert knowledge as defined by the X-ray Ordinance

    International Nuclear Information System (INIS)

    1991-01-01

    Persons applying within their role responsibility X-rays in medicine or veterinary medicine, or persons with a responsibility as radiation protection officer or according to section 24, sub-sec. (3) Radiation Protection Ordinance have to give proof of the required expert knowledge (section 3, sub-sec. (2), no. 3, section 4, sub-sec. (1) no. 3, section 13, sub-sec. (4), section 23 no.s. 1 and 3 of the X-ray Ordinance). In addition, persons applying X-rays under the supervision and responsibility of a medical specialist or dentist, have to acquire the knowledge in radiation protection as defined by section 23, no. 2 and 4 X-ray Ordinance. As to the application of X-rays in veterinary medicine, the expert knowledge required is defined in section 3, sub-sec. (2) no. 3, section 4, sub-sec. 1 no. 3, section 13, sub-sec. (4), section 29 sub-sec. (1) no. 4 of the X-ray Ordinance. The knowledge to be acquired in radiation protection is given in section 29, sub-sec. (1) no. 3 of the X-ray Ordinance. The radiation protection officer or persons responsible for radiation protection have to give proof of their expert knowledge within the course of the licensing or notification procedure in accordance with sections 3 and 4 of the X-ray Ordinance, or in the course of the procedure for appointment of a radiation protection officier in accordance with section 13, sub-sec. (3) of the X-ray Ordinance. (orig.) [de

  3. An Alternative Technique for Cementation of Cast Post and Core Restoration

    Directory of Open Access Journals (Sweden)

    Bhushan Satish Gaikwad

    2015-01-01

    Full Text Available Cementation of cast post and core restoration involves the application of luting cement in the prepared post space which is intra radicular. Commonly an endodontic instrument, lentulo spiral, and rotary hand piece at slow speed is used. Occasionally, the luting cement does not reach the base or is not uniformly spread on to the walls of the prepared post space. The inefficiency of the luting cement to cover all the surfaces of the prepared post space results in a compromised post and core treatment. An alternate procedure using a disposable syringe and needle has been described to achieve better results.

  4. CORRELATION OF SUPERNOVA REMNANT MASERS AND GAMMA-RAY SOURCES

    International Nuclear Information System (INIS)

    Hewitt, John W.; Yusef-Zadeh, Farhad; Wardle, Mark

    2009-01-01

    Supernova remnants (SNRs) interacting with molecular clouds are potentially exciting systems in which to detect evidence of cosmic ray acceleration. Prominent γ-ray emission is produced via the decay of neutral pions when cosmic rays encounter nearby dense clouds. In many of the SNRs coincident with γ-ray sources, the presence of OH (1720 MHz) masers is used to identify interaction with dense gas and to provide a kinematic distance to the system. In this Letter we use statistical tests to demonstrate that there is a correlation between these masers and a class of GeV- to TeV-energy γ-ray sources coincident with interacting remnants. For pion decay the γ-ray luminosity provides a direct estimate of the local cosmic ray density. We find the cosmic ray density is enhanced by one to two orders of magnitude over the local solar value, comparable to X-ray-induced ionization in these remnants. The inferred ionization rates are sufficient to explain non-equilibrium chemistry in the post-shock gas, where high columns of hydroxyl are observed.

  5. The post-pulmonary infarction syndrome.

    Science.gov (United States)

    Sklaroff, H J

    1979-12-01

    Following pulmonary infarction, three patients developed the classical signs and symptoms of the Dressler syndrome associated with persistent left pleural effusion. Each responded dramatically to corticosteroid therapy. While the pathogenesis of this "Post-Pulmonary Infarction syndrome," like the Dressler syndrome, is unclear, the response to corticosteroid therapy is both dramatic and diagnostic and may spare the patient prolonged discomfort and unnecessary diagnostic procedures.

  6. Determination of calcium, potassium, manganese, iron, copper and zinc levels in representative samples of two onion cultivars using total reflection X-ray fluorescence and ultrasound extraction procedure

    International Nuclear Information System (INIS)

    Alvarez, J.; Marco, L.M.; Arroyo, J.; Greaves, E.D.; Rivas, R.

    2003-01-01

    The chemical characterization of onion cultivar samples is an important tool for the enhancement of their productivity due to the fact that chemical composition is closed related to the quality of the products. A new sample preparation procedure for elemental characterization is proposed, involving the acid extraction of the analytes from crude samples by means of an ultrasonic bath, avoiding the required digestion of samples in vegetable tissue analysis. The technique of total reflection X-ray fluorescence (TXRF) was successfully applied for the simultaneous determination of the elements Ca, K, Mn, Fe, Cu and Zn. The procedure was compared with the wet ashing and dry ashing procedures for all the elements using multivariate analysis and the Scheffe test. The technique of flame atomic absorption spectrometry (FAAS) was employed for comparison purposes and accuracy evaluation of the proposed analysis method. A good agreement between the two techniques was found when using the dry ashing and ultrasound leaching procedures. The levels of each element found for representative samples of two onion cultivars (Yellow Granex PRR 502 and 438 Granex) were also compared by the same method. Levels of K, Mn and Zn were significantly higher in the 438 Granex cultivar, while levels of Ca, Fe and Cu were significantly higher in the Yellow Granex PRR 502 cultivar

  7. Modulating effect of dimethylbenzanthracene on gamma-ray mutagenesis in the soybean test system

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T. [National Inst. of Genetics, Mishima, Shizuoka (Japan); Inoue, T.

    1987-10-15

    Dimethylbenzanthracene (DMBA), a strong tumor initiator, did not show mutagenic activity in the soybean test system either alone or in combination with tumor promoter, TPA. In combination treatments with DMBA and gamma-rays, the mutagenicity of gamma-rays was not affected by post-treatment with DMBA. However, DMBA pre-treatment clearly reduced gammaray-ray induced spotting frequency, suggesting that DMBA affects mutagenesis in gamma-irradiated soybean cells.

  8. Post-Treatment Hemodynamics of a Basilar Aneurysm and Bifurcation

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, J; Hartman, J; Rodriguez, J; Maitland, D

    2008-01-16

    Aneurysm re-growth and rupture can sometimes unexpectedly occur following treatment procedures that were initially considered to be successful at the time of treatment and post-operative angiography. In some cases, this can be attributed to surgical clip slippage or endovascular coil compaction. However, there are other cases in which the treatment devices function properly. In these instances, the subsequent complications are due to other factors, perhaps one of which is the post-treatment hemodynamic stress. To investigate whether or not a treatment procedure can subject the parent artery to harmful hemodynamic stresses, computational fluid dynamics simulations are performed on a patient-specific basilar aneurysm and bifurcation before and after a virtual endovascular treatment. The simulations demonstrate that the treatment procedure produces a substantial increase in the wall shear stress. Analysis of the post-treatment flow field indicates that the increase in wall shear stress is due to the impingement of the basilar artery flow upon the aneurysm filling material and to the close proximity of a vortex tube to the artery wall. Calculation of the time-averaged wall shear stress shows that there is a region of the artery exposed to a level of wall shear stress that can cause severe damage to endothelial cells. The results of this study demonstrate that it is possible for a treatment procedure, which successfully excludes the aneurysm from the vascular system and leaves no aneurysm neck remnant, to elevate the hemodynamic stresses to levels that are injurious to the immediately adjacent vessel wall.

  9. Analytical procedure for characterization of medieval wall-paintings by X-ray fluorescence spectrometry, laser ablation inductively coupled plasma mass spectrometry and Raman spectroscopy

    International Nuclear Information System (INIS)

    Syta, Olga; Rozum, Karol; Choińska, Marta; Zielińska, Dobrochna; Żukowska, Grażyna Zofia; Kijowska, Agnieszka; Wagner, Barbara

    2014-01-01

    Analytical procedure for the comprehensive chemical characterization of samples from medieval Nubian wall-paintings by means of portable X-ray fluorescence (pXRF), laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) and Raman spectroscopy (RS) was proposed in this work. The procedure was used for elemental and molecular investigations of samples from archeological excavations in Nubia (modern southern Egypt and northern Sudan). Numerous remains of churches with painted decorations dated back to the 7th–14th century were excavated in the region of medieval kingdoms of Nubia but many aspects of this art and its technology are still unknown. Samples from the selected archeological sites (Faras, Old Dongola and Banganarti) were analyzed in the form of transfers (n = 26), small fragments collected during the excavations (n = 35) and cross sections (n = 15). XRF was used to collect data about elemental composition, LA-ICPMS allowed mapping of selected elements, while RS was used to get the molecular information about the samples. The preliminary results indicated the usefulness of the proposed analytical procedure for distinguishing the substances, from both the surface and sub-surface domains of the wall-paintings. The possibility to identify raw materials from the wall-paintings will be used in the further systematic, archeometric studies devoted to the detailed comparison of various historic Nubian centers. - Highlights: • The analytical procedure for examination of unique wall paintings was proposed. • Identification of pigments and supporting layers of wall-paintings was obtained. • Heterogeneous samples were mapped with the use of LA-ICPMS. • Anatase in the sub-surface regions of samples was detected by Raman spectroscopy

  10. Analytical procedure for characterization of medieval wall-paintings by X-ray fluorescence spectrometry, laser ablation inductively coupled plasma mass spectrometry and Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Syta, Olga; Rozum, Karol; Choińska, Marta [Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw (Poland); Zielińska, Dobrochna [Institute of Archaeology, University of Warsaw, Krakowskie Przedmieście 26/28, 00-927 Warsaw (Poland); Żukowska, Grażyna Zofia [Chemical Faculty, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw (Poland); Kijowska, Agnieszka [National Museum in Warsaw, Aleje Jerozolimskie 3, 00-495 Warsaw (Poland); Wagner, Barbara, E-mail: barbog@chem.uw.edu.pl [Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw (Poland)

    2014-11-01

    Analytical procedure for the comprehensive chemical characterization of samples from medieval Nubian wall-paintings by means of portable X-ray fluorescence (pXRF), laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) and Raman spectroscopy (RS) was proposed in this work. The procedure was used for elemental and molecular investigations of samples from archeological excavations in Nubia (modern southern Egypt and northern Sudan). Numerous remains of churches with painted decorations dated back to the 7th–14th century were excavated in the region of medieval kingdoms of Nubia but many aspects of this art and its technology are still unknown. Samples from the selected archeological sites (Faras, Old Dongola and Banganarti) were analyzed in the form of transfers (n = 26), small fragments collected during the excavations (n = 35) and cross sections (n = 15). XRF was used to collect data about elemental composition, LA-ICPMS allowed mapping of selected elements, while RS was used to get the molecular information about the samples. The preliminary results indicated the usefulness of the proposed analytical procedure for distinguishing the substances, from both the surface and sub-surface domains of the wall-paintings. The possibility to identify raw materials from the wall-paintings will be used in the further systematic, archeometric studies devoted to the detailed comparison of various historic Nubian centers. - Highlights: • The analytical procedure for examination of unique wall paintings was proposed. • Identification of pigments and supporting layers of wall-paintings was obtained. • Heterogeneous samples were mapped with the use of LA-ICPMS. • Anatase in the sub-surface regions of samples was detected by Raman spectroscopy.

  11. The X-ray signature of solar coronal mass

    Science.gov (United States)

    Harrison, R. A.; Waggett, P. W.; Bentley, R. D.; Phillips, K. J. H.; Bruner, M.

    1985-01-01

    The coronal response to six solar X-ray flares has been investigated. At a time coincident with the projected onset of the white-light coronal mass ejection associated with each flare, there is a small, discrete soft X-ray enhancement. These enhancements (precursors) precede by typically about 20 m the impulsive phase of the solar flare which is dominant by the time the coronal mass ejection has reached an altitude above 0.5 solar radii. Motions of hot X-ray emitting plasma, during the precursors, which may well be a signature of the mass ejection onsets, are identified. Further investigations have also revealed a second class of X-ray coronal transient, during the main phase of the flare. These appear to be associated with magnetic reconnection above post-flare loop systems.

  12. Comparison of apical leakage between immediate versus delayed post space preparation using two resin sealers

    Directory of Open Access Journals (Sweden)

    Priyanka Kaushal Kalra

    2009-01-01

    Full Text Available Post & Core Procedures have became an integral part of a dentist′s arsenal. This study was carried out in order to assess the microleakage when immediate and delayed post space preparations were done using resin sealers. Immediate post space preparations showed lesser apical leakage as opposed to delayed post space preparation.

  13. Cost Benefit Optimization of the Israeli Medical Diagnostic X-Ray Exposure

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Shlesinger, T.; Shani, G.; Kushilevsky, A.

    1999-01-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. A preliminary survey was carried out during 1997 on 3 major Israeli hospitals in order to assess the extent of exposure of the population to medical x-rays (1). The survey has found that the annual collective dose of the Israeli population to x-ray medical imaging procedures (excluding radio-therapy) is about 7,500 Man-Sv. The results of the survey were analyzed in order to. 1. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of the Israeli patients under x-ray procedures. 2. Establish a set of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. . Establish a number of basic rules to be utilized by health policy makers in Israel. Based on the ICRP-60 linear model risk assessments (2), the extent of the annual risk arising A.om the 7,500 Man-Sv medical x-ray collective dose in Israel has been found to be the potential addition of 567 cancer cases per year, 244 of which to be fatal, and a potential additional birth of 3-4 children with severe genetic damage per year. This assessment take into account the differential risk and the collective dose according to the age distribution in the Israeli exposed population, and excludes patients with chronic diseases

  14. X-ray safety at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Gutierrez, J.A.

    1986-11-01

    An organized and structured safety program for x-ray generating devices was initiated in October, 1979. An X-ray Device Control Office was established to manage the program that currently oversees the activities of 201 x-ray generating devices and to provide SOP reviews, perform shielding calculations, and provide training for both the operators and health physics x-ray device surveyors. The new program also establishes controls for procurement of new equipment, requires the writing of Standard Operating Procedures, requires training for operators and provides routine and non-routine safety inspections of x-ray generating devices. Prior to this program going into effect, the Laboratory had recorded nine documented x-ray related exposure accidents. Since then, there have been none. Program elements and experiences of interest to other x-ray device users are discussed. 3 refs

  15. Is There a Role for Arnica and Bromelain in Prevention of Post-Procedure Ecchymosis or Edema? A Systematic Review of the Literature.

    Science.gov (United States)

    Ho, Derek; Jagdeo, Jared; Waldorf, Heidi A

    2016-04-01

    The management of postprocedure skin care is of significant interest to dermatologists and other physicians. Ecchymosis and edema are common temporary postprocedure unwanted effects. Two botanically-derived products, arnica and bromelain, are used internationally by physicians to limit ecchymosis and edema that occur secondary to cosmetic, laser, and surgical skin procedures. The authors review the published literature and provide evidence-based recommendations on arnica and bromelain for prevention and treatment of postprocedure ecchymosis and edema. A search of the computerized bibliographic databases Medline, EMBASE, Scopus, and CINAHL was performed on March 23, 2015. The key terms used were "arnica," and "bromelain." This review contains clinical trials that evaluated prevention and/or treatment of postprocedure ecchymosis or edema with oral arnica (11), topical arnica (2), and oral bromelain (7). No studies on topical bromelain were found. Clinical trials on arnica and bromelain have demonstrated mixed results. Some randomized controlled trials reported improvement postprocedure with arnica (4/13) and bromelain (5/7). Based upon published studies, there is insufficient data to support use of arnica and bromelain post procedure, and the authors recommend additional research to determine the efficacy and safety of arnica and bromelain to prevent and/or treat ecchymosis and edema in patients.

  16. Reconstructing misaligned x-ray CT data

    Energy Technology Data Exchange (ETDEWEB)

    Divin, C. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-24

    Misalignment errors for x-ray computed tomography (CT) systems can manifest as artifacts and a loss of spatial and contrast resolution. To mitigate artifacts, significant effort is taken to determine the system geometry and minimizing any residual error in the system alignment. This project improved our ability to post-correct data which was acquired on a misaligned CT system.

  17. APE (state-oriented approach) centralized control procedures; Procedures de conduite APE (Approche Par Etats)

    Energy Technology Data Exchange (ETDEWEB)

    Astier, D. [FRAMATOME ANP, 92 - Paris-La-Defence (France); Depont, G. [Electricite de France (EDF/DPN), 93 - Saint-Denis (France); Van Dermarliere, Y. [Electricite de France (EDF/SEPTEN), 69 - Villeurbanne (France)

    2004-07-01

    This article presents the progressive implementation of the state-oriented approach (APE) for centralized control procedures in French nuclear power plants. The implementation began in the years 1982-83 and it concerned only the circuits involved in engineered safeguard systems such IS (safety injection), EAS (containment spray system) and GMPP (reactor coolant pump set). In 2003 the last PWR unit switched from the event oriented approach to APE for post-accidental situations.

  18. Diagnostic X-ray equipment evaluation in Brazil

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Peixoto, J.E.; Reis, V.R.G.

    1980-01-01

    A survey of the diagnostic X-ray equipment in use in Brazil is presented. Procedures for testing radiation quality (kilovoltage and filtration), tube output, beam collimation and protection devices are described and results of tests are tabulated. (H.K.)

  19. Characterization and error analysis of an N×N unfolding procedure applied to filtered, photoelectric x-ray detector arrays. I. Formulation and testing

    Science.gov (United States)

    Fehl, D. L.; Chandler, G. A.; Stygar, W. A.; Olson, R. E.; Ruiz, C. L.; Hohlfelder, J. J.; Mix, L. P.; Biggs, F.; Berninger, M.; Frederickson, P. O.; Frederickson, R.

    2010-12-01

    An algorithm for spectral reconstructions (unfolds) and spectrally integrated flux estimates from data obtained by a five-channel, filtered x-ray-detector array (XRD) is described in detail and characterized. This diagnostic is a broad-channel spectrometer, used primarily to measure time-dependent soft x-ray flux emitted by z-pinch plasmas at the Z pulsed-power accelerator (Sandia National Laboratories, Albuquerque, New Mexico, USA), and serves as both a plasma probe and a gauge of accelerator performance. The unfold method, suitable for online analysis, arises naturally from general assumptions about the x-ray source and spectral properties of the channel responses; a priori constraints control the ill-posed nature of the inversion. The unfolded spectrum is not assumed to be Planckian. This study is divided into two consecutive papers. This paper considers three major issues: (a) Formulation of the unfold method.—The mathematical background, assumptions, and procedures leading to the algorithm are described: the spectral reconstruction Sunfold(E,t)—five histogram x-ray bins j over the x-ray interval, 137≤E≤2300eV at each time step t—depends on the shape and overlap of the calibrated channel responses and on the maximum electrical power delivered to the plasma. The x-ray flux Funfold is estimated as ∫Sunfold(E,t)dE. (b) Validation with simulations.—Tests of the unfold algorithm with known static and time-varying spectra are described. These spectra included—but were not limited to—Planckian spectra Sbb(E,T) (25≤T≤250eV), from which noise-free channel data were simulated and unfolded. For Planckian simulations with 125≤T≤250eV and typical responses, the binwise unfold values Sj and the corresponding binwise averages ⟨Sbb⟩j agreed to ˜20%, except where Sbb≪max⁡{Sbb}. Occasionally, unfold values Sj≲0 (artifacts) were encountered. The algorithm recovered ≳90% of the x-ray flux over the wider range, 75≤T≤250eV. For lower T, the

  20. Code of safe practice for the use of x-rays in podiatry

    International Nuclear Information System (INIS)

    1990-02-01

    The purpose of this code which applies to podiatric diagnostic use of x-rays is to provide criteria for working procedures, x-ray equipment and protective materials necessary for the use of x-rays in podiatric diagnosis according to currently accepted standards of safety. Conformity with this code may be taken as a primary indication of compliance with radiation protection legislation. 5 refs

  1. Painful procedures can affect post-natal growth and neurodevelopment in preterm infants.

    Science.gov (United States)

    Coviello, Caterina; Popple Martinez, Marina; Drovandi, Livia; Corsini, Iuri; Leonardi, Valentina; Lunardi, Clara; Antonelli, Carla; Pratesi, Simone; Dani, Carlo

    2018-05-01

    This Italian study evaluated whether painful procedures during the first four weeks of life were related to subsequent weight gain, head circumference (HC) and neurodevelopmental outcomes in preterm infants, METHODS: We evaluated the number of invasive procedures that infants born at less than 32 weeks of gestational age (GA) underwent in the Neonatal Intensive Care Unit of Careggi Hospital, Florence, from January to December 2015. Weight and HC were recorded at birth, 36 weeks of PMA and six and 12 months of CA. Neurological outcomes were assessed at six and 12 months of CA using the Bayley Scales of Infant and Toddler Development - Third Edition. We studied 83 preterm infants with a GA of 28 ± 2 weeks and birth weight of 1098 ± 340 g. A higher number of invasive painful procedures were related to a lower HC standard deviation score at 36 weeks of PMA and six and 12 months of CA and with lower cognitive scores at six months. At 12 months, the relationship only remained significant for infants born at less than 28 weeks (p growth and short-term cognitive scores in preterm infants in the first year of life. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. Post-operative pain treatment in Denmark from 2000 to 2009

    DEFF Research Database (Denmark)

    Nielsen, P R; Christensen, P A; Meyhoff, C S

    2012-01-01

    In Denmark, the first acute pain service (APS) was introduced in 1993. An important objective became to facilitate implementation of accelerated post-operative rehabilitation programmes (ACC) in selected procedures in abdominal, gynaecological and orthopaedic surgery. Therefore......, it is of considerable interest to study the association between the developments of post-operative pain management and the ACC by sequential analyses from 2000 to 2009....

  3. X-ray images in the digital mode

    International Nuclear Information System (INIS)

    Buchmann, F.; Balter, S.

    1981-01-01

    In addition to computed tomography which presents actually the most important processing and transfer procedure of digital X-ray images, application of real time addition and substraction of X-ray images in a digital mode has found considerable interest. An estimation of the information contents of both digital and analog images is made in close relation to applications. As example of an image processing system on digital base a recently developed system for intravenous arteriography is described: the Philips-DVI. (orig.) [de

  4. Calibrating an ellipsometer using x-ray reflectivity

    International Nuclear Information System (INIS)

    Richter, Andrew; Guico, Rodney; Wang, Jin

    2001-01-01

    X-ray reflectivity has been used to find the optical refractive index of polymer thin film in order to calibrate a Stokes ellipsometer for film thickness measurements during the deposition procedure. A thin, spun-cast film of poly(tert-butyl acrylate) (PtBA) was made with a film thickness of ∼500 {angstrom}. An x-ray reflectivity measurement was taken and the data were fit to determine the thickness of the PtBA film and the underlying silicon--oxide layer. This measurement was then used to calculate the optical refractive index for PtBA at the ellipsometer wavelength. Using this value for the refractive index subsequently allowed us to determine the film thickness for a series of PtBA films made by using a number of polymer solution concentrations resulting in film thickness ranging from 100 to 1300 {angstrom}. These film thicknesses were found to be generally the same as those found using x-ray reflectivity. The success of this procedure suggests a useful method for calibrating an ellipsometer for fast in-lab measurements, especially on ultrathin films when simultaneous determination of the film thickness and the refractive index is less reliable

  5. A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems

    International Nuclear Information System (INIS)

    Yadava, G K; Kuhls-Gilcrist, A T; Rudin, S; Patel, V K; Hoffmann, K R; Bednarek, D R

    2008-01-01

    The performance of high-sensitivity x-ray imagers may be limited by additive instrumentation noise rather than by quantum noise when operated at the low exposure rates used in fluoroscopic procedures. The equipment-invasive instrumentation noise measures (in terms of electrons) are generally difficult to make and are potentially not as helpful in clinical practice as would be a direct radiological representation of such noise that may be determined in the field. In this work, we define a clinically relevant representation for instrumentation noise in terms of noise-equivalent detector entrance exposure, termed the instrumentation noise-equivalent exposure (INEE), which can be determined through experimental measurements of noise-variance or signal-to-noise ratio (SNR). The INEE was measured for various detectors, thus demonstrating its usefulness in terms of providing information about the effective operating range of the various detectors. A simulation study is presented to demonstrate the robustness of this metric against post-processing, and its dependence on inherent detector blur. These studies suggest that the INEE may be a practical gauge to determine and compare the range of quantum-limited performance for clinical x-ray detectors of different design, with the implication that detector performance at exposures below the INEE will be instrumentation-noise limited rather than quantum-noise limited

  6. Assessment of patients' skin dose during interventional cardiology procedures

    International Nuclear Information System (INIS)

    Tsapaki, V.; Vardalaki, E.; Kottou, S.; Molfetas, M.; Neofotistou, V.

    2002-01-01

    During the last 30 years the use of Interventional Cardiology (IC) procedures has increased significantly, mainly due to the benefits and advantages of the method that offers more accurate diagnosis and treatment along with less complications and hospitalization. However, IC procedures are based on the use of x-ray radiation, mostly localized at certain areas of patient's body and for extended periods of time. Consequently, patient may receive high radiation dose and deterministic effects, such as erythema, epilation or even dermal necrosis may be observed. Therefore, the need for reducing radiation dose is highly important. In order to achieve this, good knowledge of the dose levels delivered to the patient during IC procedures is essential since radiation effects are known to increase with dose. It is of great interest to know the point where the maximum skin dose (MSD) is noted since individual sensitivity may vary. MSDs greater than 1 Gy should be recorded. Patient dosimetry during IC procedures is a complex task since these type of procedures depend on various factors, such as complexity and severity of case, different specifications of x-ray equipment and patient's physical characteristics. Moreover, cardiologist's experience plays an important role. For these reasons, Food and Drug Administration (FDA), the International Commission on Radiological Protection (ICRP) as well as the World Health Organization (WHO), have published documents on radiation safety and ways to reduce skin injuries during IC procedures. Various methods have been proposed for measuring MSD such as the use of slow radiotherapy films, thermoluminescent detectors (TLD), scintillation detectors, Dose-Area Product (DAP) meter, as well as a combination of DAP and air kerma. A literature review on MSDs measured during IC procedures showed that doses ranged from 300 to 43000 mGy

  7. A time-averaged cosmic ray propagation theory

    International Nuclear Information System (INIS)

    Klimas, A.J.

    1975-01-01

    An argument is presented, which casts doubt on our ability to choose an appropriate magnetic field ensemble for computing the average behavior of cosmic ray particles. An alternate procedure, using time-averages rather than ensemble-averages, is presented. (orig.) [de

  8. The trickle before the torrent-diffraction data from X-ray lasers.

    Science.gov (United States)

    Maia, Filipe R N C; Hajdu, Janos

    2016-08-01

    Today Scientific Data launched a collection of publications describing data from X-ray free-electron lasers under the theme 'Structural Biology Applications of X-ray Lasers'. The papers cover data on nanocrystals, single virus particles, isolated cell organelles, and living cells. All data are deposited with the Coherent X-ray Imaging Data Bank (CXIDB) and available to the scientific community to develop ideas, tools and procedures to meet challenges with the expected torrents of data from new X-ray lasers, capable of producing billion exposures per day.

  9. Pavlovian autoshaping procedures increase plasma corticosterone and levels of norepinephrine and serotonin in prefrontal cortex in rats.

    Science.gov (United States)

    Tomie, Arthur; Tirado, Aidaluz D; Yu, Lung; Pohorecky, Larissa A

    2004-08-12

    Pavlovian autoshaping procedures provide for pairings of a small object conditioned stimulus (CS) with a rewarding substance unconditioned stimulus (US), resulting in the acquisition of complex sequences of CS-directed skeletal-motor responses or autoshaping conditioned responses (CRs). Autoshaping procedures induce higher post-session levels of corticosterone than in controls receiving CS and US randomly, and the enhanced post-session corticosterone levels have been attributed to the appetitive or arousal-inducing effects of autoshaping procedures. Enhanced corticosterone release can be induced by aversive stimulation or stressful situations, where it is often accompanied by higher levels of norepinephrine (NE) and serotonin (5-HT) in prefrontal cortex (PFC) but not in striatum (ST). Effects of autoshaping procedures on post-session corticosterone levels, NE contents in PFC, and 5-HT contents in PFC and ST were investigated in male Long-Evans rats. Post-session blood samples revealed higher corticosterone levels in the CS-US Paired group (n = 46) than in the CS-US Random control group (n = 21), and brain samples revealed higher levels of PFC NE and 5-HT in CS-US Paired group. Striatal 5-HT levels were unaltered by the autoshaping procedures. Autoshaping procedures provide for appetitive stimulation and induce an arousal-like state, as well as simultaneous stress-like changes in plasma corticosterone and monoamine levels in PFC. Autoshaping, therefore, may be useful for the study of endocrine and central processes associated with appetitive conditions.

  10. Recent achievements in the field of gamma-ray bursts

    International Nuclear Information System (INIS)

    Lu Tan; Dai Zigao

    2001-01-01

    Recent progresses in the field of gamma-ray bursts is briefly introduced. Gamma-ray bursts are the most energetic explosion since the Big Bang of the universe. Within a few tens of seconds, the energy released in gamma-ray bursts could be several hundred times larger than that released form the sun in its whole life (about 10 billion years). The authors will first briefly discuss the observational facts, based on which the authors will discuss the standard fireball model, the dynamical behavior and evolution of gamma-ray bursts and their afterglows. Then, various observational phenomena that contradict the standard model are given and the importance of these post-standard effects are pointed out. The questions related to the energy source of gamma-ray bursts are still unanswered, and other important questions also remain to be solved

  11. Diagnostic x-ray examinations in Poland in 2004 in view of the population exposure: The assessment of structure and trends

    International Nuclear Information System (INIS)

    Staniszewska, M. A.; Papierz, S.

    2006-01-01

    The paper presents the results of the Polish national survey of medical x-ray examinations performed in 2004. A questionnaire was used to collect the data on the number and types of x-ray examinations. The data covered most of x-ray laboratories in Poland, being under the dosimetric surveillance performed by the Radiation Protection Department at the Nofer Institute of Occupational Medicine in Lodz. The number of x-ray procedures in Poland in the year 2004 accounted for 32.4 million examinations, i.e. 830 procedures per 1000 inhabitants; the latter figure includes 65 specialist procedures and 61 dental examinations per 1000 of inhabitants, each. They were performed in over 3000 x-ray laboratories, including operational theatres and dental units. The majority of patients were at the age of 40-60 years and women made over 50% of all those examined. Owing to the modification of the heath care organisation, the profile of examinations performed in x-ray laboratories has changed. Nevertheless, conventional x-ray examinations are still in a majority, among which radiograph's of chest, spine and limbs are most frequently performed. It should be emphasised that the number of the hip joint radiograph's in infants and small children have decreased and practically photo fluorographic examinations have been eliminated from the diagnostic practice. The number of specialist procedures has evidently increased, and thus the frequency of these procedures in Poland and other European countries is comparable. (author)

  12. Effective segmentation of fresh post-mortem murine lung parenchyma in phase contrast X-ray tomographic microscopy images

    International Nuclear Information System (INIS)

    Oikonomidis, Ioannis Vogiatzis; Cremona, Tiziana P; Schittny, Johannes C; Lovric, Goran; Arcadu, Filippo; Stampanoni, Marco

    2017-01-01

    The acinus represents the functional unit of the mammalian lung. It is defined as the small tree of gas-exchanging airways, which is fed by the most distal purely conducting airway. Different hypotheses exist on how the fine structure of the acinus changes during ventilation and development. Since in classical 2-dimensional (2D) sections of the lung the borders of the acini are not detectable, every study of acini requires 3-dimensional (3D) datasets. As a basis for further studies of pulmonary acini we imaged rodent lungs as close to life as possible using phase contrast synchrotron radiation-based X-ray tomographic microscopy (SRXTM), and developed a protocol for the segmentation of the alveolar septa. The method is based on a combined multilevel filtering approach. Seeds are automatically defined for separate regions of tissue and airspace during each 2D filtering level and then given as input to a 3D random walk segmentation. Thus, the different types of artifacts present in the images are treated separately, taking into account the sample’s structural complexity. The proposed procedure yields high-quality 3D segmentations of acinar microstructure that can be used for a reliable morphological analysis. (paper)

  13. Preferred orientation determination using line source x-ray diffraction

    International Nuclear Information System (INIS)

    Kimmel, G.; Shmarjahu, D.

    1977-10-01

    A texture goniometer has been attached to a diffractometer connected to a line-focus x-ray source. Reasonable results are obtained for the texture of rolled sheets and the test procedure is given. To illustrate the test procedure, the determination of preferred orientation in cold-rolled copper is described, as compared with random powder of sintered copper. Improvements of the measurements are proposed

  14. Post Launch Monitoring of food products : what can be learned from pharmacovigilance

    NARCIS (Netherlands)

    van Puijenbroek, E P; Hepburn, P A; Herd, T M; van Grootheest, A C

    Post Launch Monitoring (PLM) is one of the new approaches that are used in assessing the safety of novel foods or ingredients. It shares a close resemblance with procedures applied in the field of medicines, where Post Marketing Surveillance (PMS) has been carried out since the beginning of the

  15. The studies of post-medieval glass by multivariate and X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kierzek, J.; Kunicki-Goldfinger, J.

    2002-01-01

    Multivariate statistical analysis of the results obtained by energy dispersive X-ray fluorescence analysis has been used in the study of baroque vessel glasses originated from central Europe. X-ray spectrometry can be applied as a completely non-destructive, non-sampling and multi-element method. It is very useful in the studies of valuable historical artefacts. For the last years, multivariate statistical analysis has been developed as an important tool for the archaeometric purposes. Cluster, principal component and discriminant analysis were applied for the classification of the examined objects. The obtained results show that these statistical tools are very useful and complementary in the studies of historical objects. (author)

  16. Leaf elemental analysis in mycorrhizal post oak seedlings

    Energy Technology Data Exchange (ETDEWEB)

    Boling, B.C. [Department of Biology, University of North Texas, P.O. Box 305220, Denton, TX 76203-5220 (United States); Naab, F.U. [Ion Beam Modification and Analysis Laboratory, Department of Physics, University of North Texas, P.O. Box 311427, Denton, TX 76203-1427 (United States)]. E-mail: fun001@unt.edu; Smith, D. [Department of Biology, University of North Texas, P.O. Box 305220, Denton, TX 76203-5220 (United States); Duggan, J.L. [Ion Beam Modification and Analysis Laboratory, Department of Physics, University of North Texas, P.O. Box 311427, Denton, TX 76203-1427 (United States); McDaniel, F.D. [Ion Beam Modification and Analysis Laboratory, Department of Physics, University of North Texas, P.O. Box 311427, Denton, TX 76203-1427 (United States)

    2006-09-15

    Growth and element assimilation was investigated in the leaves of post oak seedlings exposed to four different treatment combinations of fertilization and ectomycorrhizal inoculation. Element concentration was analyzed via particle-induced X-ray emission spectrometry (PIXE). PIXE detected 10 of the 13 essential macro and micronutrients: P, S, Mg, Ca, K, Cu, Zn, Mn, Fe and Cl. Mean growth and dry weight was significantly different across the treatment groups as well as the mean concentration of Mg, Al, S, K, Ca, Fe, Cu and Zn. The data suggest that fertilization rather than mycorrhizal inoculation had a stronger influence on nutrient uptake. This study is the first to analyze element concentration in post oak and to investigate the potential benefits of mycorrhizal symbiosis in post oak seedlings in terms of nutrient uptake.

  17. Realism of procedural task trainers in a pediatric emergency medicine procedures course.

    Science.gov (United States)

    Shefrin, Allan; Khazei, Afshin; Cheng, Adam

    2015-01-01

    Pediatric emergency medicine (PEM) physicians have minimal experience in life saving procedures and have turned to task trainers to learn these skills. Realism of these models is an important consideration that has received little study. PEM physicians and trainees participated in a day long procedural training course that utilized commercially available and homemade task trainers to teach pericardiocentesis, chest tube insertion, cricothyroidotomy and central line insertion. Participants rated the realism of the task trainers as part of a post-course survey. The homemade task trainers received variable realism ratings, with 91% of participants rating the pork rib chest tube model as realistic, 82% rating the gelatin pericardiocentesis mold as realistic and 36% rating the ventilator tubing cricothyroidotomy model as realistic. Commercial trainers also received variable ratings, with 45% rating the chest drain and pericardiocentesis simulator as realistic, 74% rating the crichotracheotomy trainer as realistic and 80% rating the central line insertion trainer as realistic. Task training models utilized in our course received variable realism ratings. When deciding what type of task trainer to use future courses should carefully consider the desired aspect of realism, and how it aligns with the procedural skill, balanced with cost considerations.

  18. Monte Carlo shielding analyses using an automated biasing procedure

    International Nuclear Information System (INIS)

    Tang, J.S.; Hoffman, T.J.

    1988-01-01

    A systematic and automated approach for biasing Monte Carlo shielding calculations is described. In particular, adjoint fluxes from a one-dimensional discrete ordinates calculation are used to generate biasing parameters for a Monte Carlo calculation. The entire procedure of adjoint calculation, biasing parameters generation, and Monte Carlo calculation has been automated. The automated biasing procedure has been applied to several realistic deep-penetration shipping cask problems. The results obtained for neutron and gamma-ray transport indicate that with the automated biasing procedure Monte Carlo shielding calculations of spent-fuel casks can be easily performed with minimum effort and that accurate results can be obtained at reasonable computing cost

  19. Code of safe practice for the use of x-rays in dentistry

    International Nuclear Information System (INIS)

    1991-06-01

    The purpose of this Code of Safe Practice for the Use of X-rays in Dentistry is to provide criteria for working procedures, x-ray equipment and protective materials necessary for the use of x-rays in dental diagnosis according to currently accepted standards of safety. Conformity with this code may be taken as a primary indication of compliance with radiation protection legislation. 7 refs., 1 ill

  20. Improved backscatter x-ray detection for anti-terrorist applications

    International Nuclear Information System (INIS)

    Shope, S.L.; Lockwood, G.J.; Selph, M.M.; Wehlburg, J.C.

    1999-01-01

    Currently the most common method to determine the contents of a package suspected of containing an explosive device is to use transmission radiography. This technique requires that an x-ray source and film be placed on opposite sides of the package. This poses a problem if the package is placed so that only one side is accessible, such as against a wall. There is also a threat to personnel and property since explosive devices may be booby trapped. The authors have developed a method to x-ray a package using backscattered x-rays based on similar work for landmine detection. This procedure eliminates the use of film behind the target. All of the detection is done from the same side as the source. Backscatter experiments at Sandia National Laboratories have been conducted on mock bombs in packages. They are able to readily identify the bomb components. The images that are obtained in this procedure are done in real time and the image is displayed on a computer screen. Preliminary experiments have also imaged objects within or behind a wall. They are currently using a scanning x-ray source and scintillating plastic detectors. It can take several hours to image a briefcase size object. This time could be reduced if better x-ray detection methods could be used. They have looked at using pinhole photography and CCD cameras to reduce this time

  1. Librarian driven analysis of gamma ray spectra

    International Nuclear Information System (INIS)

    Kondrashov, V.; Petersone, I.

    2002-01-01

    For a set of a priori given radionuclides extracted from a general nuclide data library, the authors use median estimates of the gamma-peak areas and estimates of their errors to produce a list of possible radionuclides matching gamma ray line(s). The identification of a given radionuclide is obtained by searching for a match with the energy information of a database. This procedure is performed in an interactive graphic mode by markers that superimpose, on the spectral data, the energy information and yields provided by a general gamma ray data library. This library of experimental data includes approximately 17,000 gamma ray energy lines related to 756 known gamma emitter radionuclides listed by the ICRP. (author)

  2. Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude?

    Directory of Open Access Journals (Sweden)

    Gökhan Pekel

    2013-01-01

    Full Text Available Purpose. This study examines the effects of fundus fluorescein angiography (FFA procedure on ocular pulse amplitude (OPA and intraocular pressure (IOP. Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females were included in this cross-sectional case series. IOP and OPA were measured with the Pascal dynamic contour tonometer before and after 5 minutes of intravenous fluorescein dye injection. Results. Pre-FFA mean OPA value was  mmHg and post-FFA mean OPA value was  mmHg (. Pre-FFA mean IOP value was  mmHg and post-FFA mean IOP value was  mmHg (. Conclusion. Although both mean OPA and IOP values were decreased after FFA procedure, the difference was not statistically significant. This clinical trial is registered with Australian New Zealand Clinical Trials Registry number ACTRN12613000433707.

  3. Diagnostic x-ray spectra measurements using a silicon surface barrier detector

    International Nuclear Information System (INIS)

    Pani, R.; Laitano, R.F.

    1987-01-01

    A silicon surface barrier detector having a low efficiency for x-ray is used to analyse diagnostic x-ray spectra. This characteristic is advantageous in overcoming experimental problems caused by high fluence rates typical of diagnostic x-ray beams. The pulse height distribution obtained with silicon surface barrier detectors is very different from the true photon spectra because of the presence of escaped Compton photons and the fact that detection efficiency falls abruptly when photon energy increases. A detailed analysis of the spurious effects involved in detection is made by a Monte Carlo method. A stripping procedure is described for implementation on a personal computer. The validity of this method is tested by comparison with experimental results obtained with a Ge detector. The spectra obtained with the Si detector are in fairly good agreement with the analogous spectra measured with a Ge detector. The advantages of using Si as opposed to Ge detectors in x-ray spectrometry are: its simplicity of use, its greater economy for use in routine diagnostic x-ray spectroscopy and the possibility that the stripping procedure can be implemented on a personal computer. (author)

  4. MCNP modelling of scintillation-detector gamma-ray spectra from natural radionuclides.

    Science.gov (United States)

    Hendriks, P H G M; Maucec, M; de Meijer, R J

    2002-09-01

    gamma-ray spectra of natural radionuclides are simulated for a BGO detector in a borehole geometry using the Monte Carlo code MCNP. All gamma-ray emissions of the decay of 40K and the series of 232Th and 238U are used to describe the source. A procedure is proposed which excludes the time-consuming electron tracking in less relevant areas of the geometry. The simulated gamma-ray spectra are benchmarked against laboratory data.

  5. A new procedure for processing extracted teeth for immediate grafting in post-extraction sockets. An experimental study in American Fox Hound dogs.

    Science.gov (United States)

    Calvo-Guirado, José Luis; Cegarra Del Pino, Pilar; Sapoznikov, Lari; Delgado Ruiz, Rafael Arcesio; Fernández-Domínguez, Manuel; Gehrke, Sérgio Alexandre

    2018-05-01

    To investigate freshly extracted dental particulate used to graft post-extraction sockets in dogs, comparing new bone formation at experimental and control sites. Bilateral premolars P2, P3, P4 and first mandibular molars were extracted atraumatically from six American Fox Hound dogs. The teeth were ground immediately using a 'Smart Dentin Grinder'. The dentin particulate was sieved to ensure a grain size of 300-1200μm and immersed in an alcohol cleanser to dissolve organic debris and bacteria, followed by washing in sterile saline buffer solution. The animals were divided into two groups randomly: group 'A' (control) samples were left to heal without any extraction socket grafting procedure; group 'B' (experimental) sockets were filled with the autogenous dentin particulate graft. The rate of tissue healing and the quantity of bone formation were evaluated using histological and histomorphometric analyses at 60 and 90 days post-grafting. The type of bone generated was categorized as woven (immature bone) or lamellar bone (mature bone). Substantially more bone formation was found in Group B (experimental) than Group A (control) at 60 and 90 days (psocket preservation, protecting both buccal and lingual plates, generating large amounts of new woven bone formation after 60 days, and small amounts of lamellar bone after 90 days healing. Copyright © 2018 Elsevier GmbH. All rights reserved.

  6. Relationship between X-ray irradiation and chromosomal damage in bone marrow tissue of mice

    International Nuclear Information System (INIS)

    Chaubey, R.C.; George, K.P.; Sundaram, K.

    1976-01-01

    X-ray induced chromosomal damage in bone-marrow tissue of male mice was studied using micronucleus technique. Dose response relationship was evaluated. Male Swiss mice received whole body x-ray irradiation at different doses from 25-1000 rads. Animals were sacrificed at the end of 24 hours, bone-marrow smears were made and stained in May-Grunwald-Giemsa. The preparatians were scored for the following types of aberrations: micronuclei in young erythocytes-polychromatic cells and in the mature erythrocytes-normechromatic cells. A dose dependent increase in the frequency of micronuclei in polychromatic cells up to a dose of 100 rads was observed. In addition the effect of post-irradiation duration on the frequency of micronuclei in polychromatic and normochromatic cells were studied. Male Swiss mice were exposed to 200 rads x-rays and were then sacrificed at different time intervals after irradiation and bone-marrow preparations were made and scored. Maximum polychromatic cells with micronuclei were observed in 24 hours post-irradiated animals, thereafter a decrease in the frequency of polychromatic cells with micronuclei was observed in 40 hours post irradiated animals. (author

  7. Radiographic implications of procedures involving cardiac implantable electronic devices (CIEDs – Selected aspects

    Directory of Open Access Journals (Sweden)

    Roman Steckiewicz

    2017-06-01

    Full Text Available Background: Some cardiac implantable electronic device (CIED implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT and dose-area product (DAP – defined as the absorbed dose multiplied by the area irradiated. Material and Methods: This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement procedures in 176 women and 346 men (mean age 75±11 years over the period 2012–2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM and 171 implantable cardioverter-defibrillator (ICD implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures. Results: We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD – intermediate (with values for single-chamber considerably lower than those for dual-chamber systems and CRT implantation procedures – highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters. Conclusions: Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3:363–374

  8. Recent advances in ratio primary reference measurement procedures (definitive methods) and their use in certification of reference materials and controlling assigned values in proficiency testing

    International Nuclear Information System (INIS)

    Dybczyñski, R.S.; Polkowska-Motrenko, H.; Chajduk, E.; Danko, B.; Pyszynska, M.

    2014-01-01

    The idea of definitive methods based on radiochemical neutron activation analysis (RNAA), consists in combination of neutron activation with the highly selective and quantitative post-irradiation isolation of the desired radionuclide by column chromatography followed by γ-ray spectrometric measurement. The principles of construction of such methods, which were devised in the Institute of Nuclear Chemistry and Technology, are reminded and the significance of these methods for analytical quality assurance is emphasized. According to VIM 3 nomenclature these methods may be called: ratio primary reference measurement procedures (RPRMPs). RPRMP for the determination of Se is briefly presented and its use for checking the accuracy of 'assigned values' established by expert laboratories in some proficiency tests, is demonstrated

  9. Radioprotective effects in mice by a single dose of subcutaneous administration of cobaltous chloride post γ-rays irradiation with a sublethal dose

    International Nuclear Information System (INIS)

    Izumo, Yoshiro; Ogata, Hiromitsu

    1993-01-01

    Radioprotective effects were investigated in mice which received subcutaneously a single dose of each inorganic metal: Co, Cu, Rb, Sr, Mo and W 24 hours post irradiation of 60 Co γ-rays with a sublethal dose. The effects were observed in mice injected with Co at an optimum dosage of 20 mg/kg·body weight. Then to elucidate mechanisms of the effects, mice were injected with Co containing the radioactive tracer ( 60 Co) following the radiation exposure, measured elimination of the radioactivity for 7 days, then sacrificed and divided to some tissues and organs. The radioactivity in whole body during this period resulted in a markedly higher retention than that for mice injected with [ 60 Co] alone, as well as liver in the organs. These higher retentions appeared to be related to the radioprotective effects. (author)

  10. The Role of Nonsteroidal Anti-Inflammatory Drugs (NSAIDs in the Management of the Post-Embolization Symptoms after Uterine Artery Embolization

    Directory of Open Access Journals (Sweden)

    Tiago Bilhim

    2010-05-01

    Full Text Available Uterine artery embolization (UAE is usually a very painful procedure. Although pain after the procedure can occur as a single symptom, it usually is associated with other symptoms such as nausea, vomiting, pelvic pain, general malaise, fever and leukocytosis that characterize the post-embolization syndrome. Management of the post-embolization symptoms and of pain in particular, is paramount if UAE is to be performed as an outpatient procedure. Different protocols have used analgesic and/or anti-inflammatory agents to control these symptoms. Nonsteroidal anti-inflammatory drugs (NSAIDs are frequently used in association with analgesic drugs to control post-embolization symptoms. In our institution the patients start oral medication with NSAIDs the day before the procedure and continue it during and after UAE. We also mix NSAIDs with the embolizing particles. This enables a reduction in the inflammation present in the uterine fibroids and helps controlling the pain. The purpose of this paper is to review the importance of NSAIDs in the management of the post-embolization symptoms. We describe the protocol that we use in our institution that enables us to perform the procedure on an outpatient basis with same day discharge and good control of the post-embolization symptoms with oral NSAIDs and analgesics.

  11. New procedure for sampling infiltration to assess post-fire soil water repellency

    Science.gov (United States)

    P. R. Robichaud; S. A. Lewis; L. E. Ashmun

    2008-01-01

    The Mini-disk Infiltrometer has been adapted for use as a field test of post-fire infiltration and soil water repellency. Although the Water Drop Penetration Time (WDPT) test is the common field test for soil water repellency, the Mini-disk Infiltrometer (MDI) test takes less time, is less subjective, and provides a relative infiltration rate. For each test, the porous...

  12. Effect of UV on the post irradiated Li Cs S O{sub 4} crystal by X and gamma radiation. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Kassem, M E [On Leave, Alexandria University, Faculty of Science, PHysics Department. Alexandria (Egypt); EL-Kolaly, M A [On Leave, Radiation Protection Department, Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt); Al-Houty, L I [University of Qatar, Faculty of Science, Department of Physics, P.O. Box 2713, Doha (Qatar)

    1996-03-01

    Thermoluminescence characteristics of Li Cs S O{sub 4} crystal have been studied after exposure to different doses of X and Gamma-Radiations. The glow curves showed TL response of Three peaks at 75,125 and 250 degree C. The structure of the glow peaks due to X-rays is quite different from that due to gamma-rays. UV exposure yields regeneration of the TL peaks for the post irradiated samples with X or Gamma-radiation with some changes in the peaks`s structure especially the third peak. For the post X-ray irradiated crystals, the area under the third glow peak (PK III) increased with integrated time of UV exposure till about 30 min after which no changes were observed; while, for the post gamma-irradiated crystals, two linear regions were observed. The models of the TL response for the post irradiated samples as a result to UV are discussed. 5 figs.

  13. [Exploration of how to formulate guidelines on post-marketing traditional Chinese medicine surveillance].

    Science.gov (United States)

    Zhang, Wen; Xie, Yan-Ming; Yu, Wen-Ya

    2013-09-01

    Combining the world health organization's (WHO), the United States and the European union's relevant laws and guidelines on post-marketing drug surveillance to judge the status of post-marketing surveillance of traditional Chinese medicine(TCM) in China. We found that due to the late start of post-marketing surveillance of traditional Chinese medicine, the appropriate guidelines are yet to be developed. Hence, hospitals, enterprises and research institutions do not have a shared foundation from which to compare their research results. Therefore there is an urgent need to formulate such post-marketing surveillance guidelines. This paper has used as guidance various technical documents such as, "procedures to formulate national standards" and "testing methods of management in formulating traditional Chinese medicine standards" and has combined these to produce a version of post-marketing surveillance particular to Chinese medicine in China. How to formulate these guidelines is discussed and procedures and methods to formulate technical specifications are introduced. These provide a reference for future technical specifications and will assist in the development of TCM.

  14. Time series data correction for the Chang'E-1 gamma-ray spectrometer

    Institute of Scientific and Technical Information of China (English)

    Li-Yan Zhang; Yong-Liao Zou; Jian-Zhong Liu; Jian-Jun Liu; Ji Shen; Ling-Li Mu; Xin Ren; Wei-Bin Wen; Chun-Lai Li

    2011-01-01

    The main goal of the gamma-ray spectrometer (GRS) onboard Chang'E-l (CE-1) is to acquire global maps of elemental abundances and their distributions on the moon, since such maps will significantly improve our understanding of lunar formation and evolution. To derive the elemental maps and enable research on lunar formation and evolution, raw data that are received directly from the spacecraft must be converted into time series corrected gamma-ray spectra. The data correction procedures for the CE-1 GRS time series data are thoroughly described. The processing procedures to create the time series gamma-ray spectra described here include channel processing, optimal data selection, energy calibration, gain correction, dead time correction, geometric correction, orbit altitude normalization, eliminating unusable data and galactic cosmic ray correction. Finally, descriptions are also given on data measurement uncertainties, which will help the interested scientists to understand and estimate various uncertainties associated with the above data processing.

  15. Time series data correction for the Chang'E-1 gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Zhang Liyan; Zou Yongliao; Liu Jianzhong; Liu Jianjun; Shen Ji; Mu Lingli; Ren Xin; Wen Weibin; Li Chunlai

    2011-01-01

    The main goal of the gamma-ray spectrometer (GRS) onboard Chang'E-1 (CE-1) is to acquire global maps of elemental abundances and their distributions on the moon, since such maps will significantly improve our understanding of lunar formation and evolution. To derive the elemental maps and enable research on lunar formation and evolution, raw data that are received directly from the spacecraft must be converted into time series corrected gamma-ray spectra. The data correction procedures for the CE-1 GRS time series data are thoroughly described. The processing procedures to create the time series gamma-ray spectra described here include channel processing, optimal data selection, energy calibration, gain correction, dead time correction, geometric correction, orbit altitude normalization, eliminating unusable data and galactic cosmic ray correction. Finally, descriptions are also given on data measurement uncertainties, which will help the interested scientists to understand and estimate various uncertainties associated with the above data processing. (research papers)

  16. God and religion in post-modern philosophers

    Directory of Open Access Journals (Sweden)

    José J. Queiroz

    2016-12-01

    Full Text Available This paper is an essay on the positions of some post-modern philosophers on religion, with the debate about post-modernity as a background. Its preliminary objective is to situate post-modernity taking a position between plain acceptance and categorical refusal in contemporary society. In this polemical field, the paper focuses on three important post-modern philosophers by pointing their contributions for a new thinking about religion today. The procedure consists in the reading of the authors´ texts looking for an interpretation of their discourses on God, religion and the sacred. The conclusion is that post-modernity is not as new era overcoming modernity, but that it is comprised of new themes  that are on the fringes  or even  in opposite directions of modernity´s parameters . One can find these themes in many fields of human knowledge including theology and science of religion. On Derrida´s position, who is the most focused philosopher, the text is still embryonic as it comes from ongoing research.  

  17. Sensitivity of in vivo X-ray fluorescence determination of skeletal lead stores

    International Nuclear Information System (INIS)

    Sokas, R.K.; Besarab, A.; McDiarmid, M.A.; Shapiro, I.M.; Bloch, P.

    1990-01-01

    Eighteen patients with known past occupational lead exposure underwent parenteral diagnostic chelation with ethylenediaminetetraacetic acid and x-ray fluorescent determination of in vivo skeletal lead stores at the distal styloid process of the ulna and at the temporal base bone using a cobalt 57 source and measuring lead Ka x-rays. X-ray fluorescent lead measurements in both locations correlated with results of diagnostic chelation. Using a post-chelation urinary excretion of greater than 600 micrograms lead/24 h as the definition of high-lead stores, sensitivity of x-ray fluorescence at the wrist and temple was 56% and 39%, respectively

  18. Line shape and ray trace calculations in saturated X-ray lasers: Application to Ni-like silver

    International Nuclear Information System (INIS)

    Benredjem, D.; Guilbaud, O.; Moeller, C.; Klisnick, A.; Ros, D.; Dubau, J.; Calisti, A.; Talin, B.

    2006-01-01

    Longitudinal coherence length in X-ray lasers depends strongly on the shape of the amplified line. We have modelled an experiment performed at the LULI facility of Ecole Polytechnique. The experiment was devoted to the study of the temporal (longitudinal) coherence of the transient Ni-like silver 4d-4p transition X-ray laser at 13.9 nm. Accurate line shape calculations using PPP, a spectral line shape code, confirm that the Voigt profile is a good approximation for this X-ray laser line. This allows us to extensively use the Voigt shape in conditions where the amplifier, i.e. the plasma produced by the interaction of a high intensity laser with a slab target, is neither stationary nor homogeneous. Our calculations involve a ray trace code which is a post-processor to the hydrodynamic simulation EHYBRID. As the effect of saturation is important for the level populations and gains we include the interaction between the amplified beam and the medium using the Maxwell-Bloch formalism. While the FWHM of the spontaneous emission profile is ∼10 mA, the amplified X-ray line exhibits gain narrowing leading to the smaller width ∼3 mA. Comparison with experiment is discussed

  19. Post Operative Cognitive Dysfunction (POCD in Geriatric Population

    Directory of Open Access Journals (Sweden)

    Rajesh MC

    2015-10-01

    Full Text Available Post-operative mental dysfunction and confusion in aged patients is a well recognized entity. Commonly known as post-operative delirium and cognitive dysfunction (POCD, these are important for any peri-operative physician dealing with geriatric population. The incidence is more in older patients with pre-existing impairment. Impact of POCD is grave. This can result in poor rehabilitation outcome and increased hospital stay. Incidence ranges from 15-50% with ˂5% for cataract surgery and as high as 60% after hip replacement procedures.

  20. Characterization and error analysis of an N×N unfolding procedure applied to filtered, photoelectric x-ray detector arrays. I. Formulation and testing

    Directory of Open Access Journals (Sweden)

    D. L. Fehl

    2010-12-01

    Full Text Available An algorithm for spectral reconstructions (unfolds and spectrally integrated flux estimates from data obtained by a five-channel, filtered x-ray-detector array (XRD is described in detail and characterized. This diagnostic is a broad-channel spectrometer, used primarily to measure time-dependent soft x-ray flux emitted by z-pinch plasmas at the Z pulsed-power accelerator (Sandia National Laboratories, Albuquerque, New Mexico, USA, and serves as both a plasma probe and a gauge of accelerator performance. The unfold method, suitable for online analysis, arises naturally from general assumptions about the x-ray source and spectral properties of the channel responses; a priori constraints control the ill-posed nature of the inversion. The unfolded spectrum is not assumed to be Planckian. This study is divided into two consecutive papers. This paper considers three major issues: (a Formulation of the unfold method.—The mathematical background, assumptions, and procedures leading to the algorithm are described: the spectral reconstruction S_{unfold}(E,t—five histogram x-ray bins j over the x-ray interval, 137≤E≤2300  eV at each time step t—depends on the shape and overlap of the calibrated channel responses and on the maximum electrical power delivered to the plasma. The x-ray flux F_{unfold} is estimated as ∫S_{unfold}(E,tdE. (b Validation with simulations.—Tests of the unfold algorithm with known static and time-varying spectra are described. These spectra included—but were not limited to—Planckian spectra S_{bb}(E,T (25≤T≤250  eV, from which noise-free channel data were simulated and unfolded. For Planckian simulations with 125≤T≤250  eV and typical responses, the binwise unfold values S_{j} and the corresponding binwise averages ⟨S_{bb}⟩_{j} agreed to ∼20%, except where S_{bb}≪max⁡{S_{bb}}. Occasionally, unfold values S_{j}≲0 (artifacts were encountered. The algorithm recovered ≳90% of the x-ray

  1. X-ray pulse wavefront metrology using speckle tracking

    International Nuclear Information System (INIS)

    Berujon, Sebastien; Ziegler, Eric; Cloetens, Peter

    2015-01-01

    The theoretical description and experimental implementation of a speckle-tracking-based instrument which permits the characterisation of X-ray pulse wavefronts. An instrument allowing the quantitative analysis of X-ray pulsed wavefronts is presented and its processing method explained. The system relies on the X-ray speckle tracking principle to accurately measure the phase gradient of the X-ray beam from which beam optical aberrations can be deduced. The key component of this instrument, a semi-transparent scintillator emitting visible light while transmitting X-rays, allows simultaneous recording of two speckle images at two different propagation distances from the X-ray source. The speckle tracking procedure for a reference-less metrology mode is described with a detailed account on the advanced processing schemes used. A method to characterize and compensate for the imaging detector distortion, whose principle is also based on speckle, is included. The presented instrument is expected to find interest at synchrotrons and at the new X-ray free-electron laser sources under development worldwide where successful exploitation of beams relies on the availability of an accurate wavefront metrology

  2. Problems with film processing in medical X-ray imaging in Lithuania

    International Nuclear Information System (INIS)

    Sniureviciute, M.; Adliene, D.

    2005-01-01

    Optimisation in X-ray imaging in order to reduce patient doses during diagnostic X-ray examinations is a complex process given the high level of image quality required. When quality systems are implemented as a basis for optimisation, attention should be paid to the qualifications of the staff and quality control of the equipment and of the X-ray imaging procedures, as well as to the methods used to evaluate the quality of these procedures. Until recently, quality control procedures at health care institutions in Lithuania were limited to the testing of X-ray units. Since film processing is one of the most important factors influencing patient doses and image quality during X-ray examinations, in 2003 the Kaunas department of the Radiation Protection Centre organised inspections of film processing laboratories in 11 health care institutions - hospitals and outpatient departments - in the Kaunas region. Problems of non-compliance with requirements identified during these inspections are discussed in this paper. Most of the health care institutions inspected already had quality assurance programmes. However, the implementation of these programmes was sometimes erratic because of the insufficient attention paid to the film developing processes. The worst situation was found in 4 institutions where the films were developed manually. Only 3 of the 11 departments inspected had sensitometers and densitometers for quality control of the processing. In many cases there was no control of chemicals, film sensitivity and density, or else control was irregular. In only a few departments were the effects of repeated controls investigated and discussed. Despite the current problems occurring in medical X-ray diagnostic departments in Lithuania, the situation is rapidly improving. New equipment is being installed, new devices for quality control are being used and, last but not least, the view of hospital administrators, radiologists and laboratory workers towards quality

  3. X-RAY PROPERTIES OF YOUNG EARLY-TYPE GALAXIES. I. X-RAY LUMINOSITY FUNCTION OF LOW-MASS X-RAY BINARIES

    International Nuclear Information System (INIS)

    Kim, Dong-Woo; Fabbiano, Giuseppina

    2010-01-01

    We have compared the combined X-ray luminosity function (XLF) of low-mass X-ray binaries (LMXBs) detected in Chandra observations of young, post-merger elliptical galaxies with that of typical old elliptical galaxies. We find that the XLF of the 'young' sample does not present the prominent high-luminosity break at L X > 5 x 10 38 erg s -1 found in the old elliptical galaxy XLF. The 'young' and 'old' XLFs differ with a 3σ statistical significance (with a probability less than 0.2% that they derive from the same underlying parent distribution). Young elliptical galaxies host a larger fraction of luminous LMXBs (L X > 5 x 10 38 erg s -1 ) than old elliptical galaxies and the XLF of the young galaxy sample is intermediate between that of typical old elliptical galaxies and that of star-forming galaxies. This observational evidence may be related to the last major/minor mergers and the associated star formation.

  4. MCNP modelling of scintillation-detector gamma-ray spectra from natural radionuclides

    NARCIS (Netherlands)

    Hendriks, Peter; Maucec, M; de Meijer, RJ

    gamma-ray spectra of natural radionuclides are simulated for a BGO detector in a borehole geometry using the Monte Carlo code MCNP. All gamma-ray emissions of the decay of K-40 and the series of Th-232 and U-238 are used to describe the source. A procedure is proposed which excludes the

  5. Comparison of pancuronium and vecuronium for fetal neuromuscular blockade during invasive procedures.

    Science.gov (United States)

    Watson, W J; Atchison, S R; Harlass, F E

    1996-01-01

    Neuromuscular blocking agents, used to arrest fetal motion for invasive intrauterine procedures, may cause temporary fetal heart rate changes. After 21 invasive procedures using either pancuronium bromide or vecuronium bromide, post-procedure fetal heart rate tracings were retrospectively compared. Pancuronium was associated with an increased fetal heart rate and decreased beat-to-beat variability for 2.5 hours after its use, whereas vecuronium caused no fetal heart rate changes. Vecuronium bromide offers advantages over pancuronium, because the decreased effect on the fetal heart allows better assessment of fetal well-being immediately following invasive intrauterine procedures.

  6. A comparison of the performance of a fundamental parameter method for analysis of total reflection X-ray fluorescence spectra and determination of trace elements, versus an empirical quantification procedure

    Science.gov (United States)

    W(egrzynek, Dariusz; Hołyńska, Barbara; Ostachowicz, Beata

    1998-01-01

    The performance has been compared of two different quantification methods — namely, the commonly used empirical quantification procedure and a fundamental parameter approach — for determination of the mass fractions of elements in particulate-like sample residues on a quartz reflector measured in the total reflection geometry. In the empirical quantification procedure, the spectrometer system needs to be calibrated with the use of samples containing known concentrations of the elements. On the basis of intensities of the X-ray peaks and the known concentration or mass fraction of an internal standard element, by using relative sensitivities of the spectrometer system the concentrations or mass fractions of the elements are calculated. The fundamental parameter approach does not require any calibration of the spectrometer system to be carried out. However, in order to account for an unknown mass per unit area of a sample and sample nonuniformity, an internal standard element is added. The concentrations/mass fractions of the elements to be determined are calculated during fitting a modelled X-ray spectrum to the measured one. The two quantification methods were applied to determine the mass fractions of elements in the cross-sections of a peat core, biological standard reference materials and to determine the concentrations of elements in samples prepared from an aqueous multi-element standard solution.

  7. Measurement of density distribution of a cracking catalyst in experimental riser with a sampling procedure for gamma ray tomography

    International Nuclear Information System (INIS)

    Dantas, C.C.; Melo, S.B.; Oliveira, E.F.; Simoes, F.P.M.; Santos, M.G. dos; Santos, V.A. dos

    2008-01-01

    By scanning a riser the number of the gamma ray trajectories and the beam width involve temporal, spatial and density resolutions as they are closely correlated parameters. Therefore, evaluation of parameters and their interaction quantification, certainly, are required in the imaging process. Measuring the density distribution of the catalyst from the FCC - fluid cracking catalytic process in an experimental riser in single beam tomographic system, density resolution is evaluated and correlated with spatial resolution. The beam width Δs inside riser is measured and a criterion for determining spatial resolution is proposed. Experiments are carried out to demonstrate resolution effects of three Δs values: 3.30 x 10 -3 , 6.20 x 10 -3 and 12.00 x 10 -3 m. The gamma beam profile is modeled and a sampling rate according to Nyquist criterion is analyzed. The 4.3%, 8.1% and 15.6% ratios of Δs/R to internal riser radius are correlated to counting time in the sampling procedure. Results are discussed by comparison with values from literature

  8. The skew ray ambiguity in the analysis of videokeratoscopic data.

    Science.gov (United States)

    Iskander, D Robert; Davis, Brett A; Collins, Michael J

    2007-05-01

    Skew ray ambiguity is present in most videokeratoscopic measurements when azimuthal components of the corneal curvature are not taken into account. There have been some reported studies based on theoretical predictions and measured test surfaces suggesting that skew ray ambiguity is significant for highly deformed corneas or decentered corneal measurements. However, the effect of skew ray ambiguity in ray tracing through videokeratoscopic data has not been studied in depth. We have evaluated the significance of the skew ray ambiguity and its effect on the analyzed corneal optics. This has been achieved by devising a procedure in which we compared the corneal wavefront aberrations estimated from 3D ray tracing with those determined from 2D (meridional based) estimates of the refractive power. The latter was possible due to recently developed concept of refractive Zernike power polynomials which links the refractive power domain with that of the wavefront. Simulated corneal surfaces as well as data from a range of corneas (from two different Placido disk-based videokeratoscopes) were used to find the limit at which the difference in estimated corneal wavefronts (or the corresponding refractive powers) would have clinical significance (e.g., equivalent to 0.125 D or more). The inclusion/exclusion of the skew ray in the analyses showed some differences in the results. However, the proposed procedure showed clinically significant differences only for highly deformed corneas and only for large corneal diameters. For the overwhelming majority of surfaces, the skew ray ambiguity is not a clinically significant issue in the analysis of the videokeratoscopic data indicating that the meridional processing such as that encountered in calculation of the refractive power maps is adequate.

  9. Effects of gamma-ray radiation on activity and apoptosis of rat cardiomyocytes in vitro

    International Nuclear Information System (INIS)

    Hu Shunying; Jiang Changsheng; Chen Guowei; Duan Haifeng; Wang Rongliang; Wu Bin; Guo Zikuan; Wang Lisheng

    2007-01-01

    Objective: It is reported that radiation-induced myocardial degeneration in the rat is preceded by changes in capillary structure and function. The aim of the present study is to investigate direct effect of gamma ray radiation on activity and apoptosis of cultured rat cardiomyocytes in vitro. Methods: The study was performed using primary cell cultures of cardiomyocytes isolated from hearts of now-born rats. After being cultured for 72h in vitro, cardiomyocytes were irradiated with single dose of 5 Gy, 10 Gy, 20 Gy of gamma ray respectively. At 48h post-irradiation, the concentration of LDH in the supernatant of cell culture was tested using methods introduced by International Federation of clinical chemistry (IFCC), and apoptosis was determined with flow cytometry. The viability of myocytes was determined with crystal violet test and MTT test at 48h and 120h post-irradiation respectively. Results: LDH concentration in the supernatant of cell culture of cardiomyocytes were increased significantly with the irradiation dose augment. Flow cytometry confirmed the induction of apoptosis in response to different gamma ray doses irradiation at 48h after irradiation. The viable cardiomyocytes irradiated by gamma ray were significantly declined at 120h after irradiation compared to un-irradiated cells, however there were no significant difference between two groups at 48h post-irradiation. Dose-effect relationship was demonstrated between cardiomyocyte apoptosis, viability and irradiation dose in the study. Conclusion: The study demonstrates gamma ray radiation can cause direct damage to cultured cardiomyocytes, including inhibiting activity and inducing apoptosis of cardiomyocytes in vitro, which shows dose effect relationship. The mechanism of gamma ray irradiation induced injury to cardiomyocytes should be investigated further. (authors)

  10. Physically based modelling and optimal operation for product drying during post-harvest processing.

    NARCIS (Netherlands)

    Boxtel, van A.J.B.; Lukasse, L.; Farkas, I.; Rendik, Z.

    1996-01-01

    The development of new procedures for crop production and post-harvest processing requires models. Models based on physical backgrounds are most useful for this purpose because of their extrapolation potential. An optimal procedure is developed for alfalfa drying using a physical model. The model

  11. Cosmic ray spectroscopy using plastic scintillator detector

    International Nuclear Information System (INIS)

    Rudra, Sharmili; Nandan, Akhilesh P.; Neog, Himangshu; Biswas, S.; Mohanty, B.; Mahapatra, S.; Samal, P.K.

    2014-01-01

    A simple and new technique has been developed using plastic scintillator detectors for cosmic ray spectroscopy without single channel analyzer (SCA) or multichannel analyzer (MCA). In this technique only a leading edge discriminator (LED) and a NIM scaler have been used. Plastic scintillator detectors has been used to measure the velocity of cosmic ray muons. Here the time difference has been measured from the Tektronix DPO 5054 digital phosphor oscilloscope with 500 MHz and 5 GS/s. The details of experimental technique, analysis procedure and experimental results are presented

  12. Patient doses from fluoroscopically guided cardiac procedures in pediatrics

    Science.gov (United States)

    Martinez, L. C.; Vano, E.; Gutierrez, F.; Rodriguez, C.; Gilarranz, R.; Manzanas, M. J.

    2007-08-01

    Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for <1 year; 52 for 1-<5 years; 25 for 5-<10 years and 13 for 10-<16 years. Median values of KAP were 1.9, 2.9, 4.5 and 15.4 Gy cm2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers.

  13. Procedures for sampling radium-contaminated soils

    International Nuclear Information System (INIS)

    Fleischhauer, H.L.

    1985-10-01

    Two procedures for sampling the surface layer (0 to 15 centimeters) of radium-contaminated soil are recommended for use in remedial action projects. Both procedures adhere to the philosophy that soil samples should have constant geometry and constant volume in order to ensure uniformity. In the first procedure, a ''cookie cutter'' fashioned from pipe or steel plate, is driven to the desired depth by means of a slide hammer, and the sample extracted as a core or plug. The second procedure requires use of a template to outline the sampling area, from which the sample is obtained using a trowel or spoon. Sampling to the desired depth must then be performed incrementally. Selection of one procedure over the other is governed primarily by soil conditions, the cookie cutter being effective in nongravelly soils, and the template procedure appropriate for use in both gravelly and nongravelly soils. In any event, a minimum sample volume of 1000 cubic centimeters is recommended. The step-by-step procedures are accompanied by a description of the minimum requirements for sample documentation. Transport of the soil samples from the field is then addressed in a discussion of the federal regulations for shipping radioactive materials. Interpretation of those regulations, particularly in light of their application to remedial action soil-sampling programs, is provided in the form of guidance and suggested procedures. Due to the complex nature of the regulations, however, there is no guarantee that our interpretations of them are complete or entirely accurate. Preparation of soil samples for radium-226 analysis by means of gamma-ray spectroscopy is described

  14. 48 CFR 504.570 - Procedures for using the EPS.

    Science.gov (United States)

    2010-10-01

    ... GENERAL ADMINISTRATIVE MATTERS Electronic Commerce in Contracting 504.570 Procedures for using the EPS. (a... [Identify address block in the solicitation]. (e) The Electronic Posting System Manual provides detailed... that electronic access to a solicitation will result in adequate competition, distribute the...

  15. Thoracoscopic pulmonary wedge resection without post-operative chest drain

    DEFF Research Database (Denmark)

    Holbek, Bo Laksafoss; Hansen, Henrik Jessen; Kehlet, Henrik

    2016-01-01

    %) patients had a pneumothorax of mean size 12 ± 12 mm on supine 8-h post-operative X-ray for which the majority resolved spontaneously within 2-week control. There were no complications on 30-day follow-up. Median length of stay was 1 day. CONCLUSIONS: The results support that VATS wedge resection...

  16. Robotic pancreas drainage procedure for chronic pancreatitis: robotic lateral pancreaticojejunostomy (Puestow procedure).

    Science.gov (United States)

    Khan, Adeel S; Siddiqui, Imran; Vrochides, Dionisios; Martinie, John B

    2018-01-01

    Lateral pancreaticojejunostomy (LPJ), also known as the Puestow procedure, is a complex surgical procedure reserved for patients with refractory chronic pancreatitis (CP) and a dilated pancreatic duct. Traditionally, this operation is performed through an open incision, however, recent advancements in minimally invasive techniques have made it possible to perform the surgery using laparoscopic and robotic techniques with comparable safety. Though we do not have enough data yet to prove superiority of one over the other, the robotic approach appears to have an advantage over the laparoscopic technique in better visualization through 3-dimensional (3D) imaging and availability of wristed instruments for more precise actions, which may translate into superior outcomes. This paper is a description of our technique for robotic LPJ in patients with refractory CP. Important principles of patient selection, preoperative workup, surgical technique and post-operative management are discussed. A short video with a case presentation and highlights of the important steps of the surgery is included.

  17. Expert knowledge as defined by the X-Ray Ordinance

    International Nuclear Information System (INIS)

    1987-01-01

    The radiation protection officer or any person responsible for radiation safety have to give proof of their expert knowledge in accordance with sections 3, 4 of the X-Ray Ordinance. Proof of expert knowledge has to be furnished within the procedure of appointment (sec. 13, sub-sec. (3) X-Ray Ordinance). The directive defines the scope of the expert knowledge required, and the scope of expert knowledge persons must have, or acquire, who are responsible for radiation protection within the preview of sec. 23, no. 2, 4 and sec. 29, sub-sec. 1, no. 3 of the X-Ray Ordinance. (orig./HP) [de

  18. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  19. Test plan/procedure for the SPM-1 shipping container system. Revision 0

    International Nuclear Information System (INIS)

    Flanagan, B.D.

    1995-01-01

    The 49 CFR 173.465 Type A packaging tests will verify that SPM-1 will provide adequate protection and pass as a Type A package. Test will determine that the handle of the Pig will not penetrate through the plywood spacer and rupture the shipping container. Test plan/procedure provides planning, pre-test, setup, testing, and post-testing guidelines and procedures for conducting the open-quotes Free Drop Testclose quotes procedure for the SPM-1 package

  20. Studies of oxide-based thin-layered heterostructures by X-ray scattering methods

    Energy Technology Data Exchange (ETDEWEB)

    Durand, O. [Thales Research and Technology France, Route Departementale 128, F-91767 Palaiseau Cedex (France)]. E-mail: olivier.durand@thalesgroup.com; Rogers, D. [Nanovation SARL, 103 bis rue de Versailles 91400 Orsay (France); Universite de Technologie de Troyes, 10-12 rue Marie Curie, 10010 (France); Teherani, F. Hosseini [Nanovation SARL, 103 bis rue de Versailles 91400 Orsay (France); Andrieux, M. [LEMHE, ICMMOCNRS-UMR 8182, Universite d' Orsay, Batiment 410, 91410 Orsay (France); Modreanu, M. [Tyndall National Institute, Lee Maltings, Prospect Row, Cork (Ireland)

    2007-06-04

    Some X-ray scattering methods (X-ray reflectometry and Diffractometry) dedicated to the study of thin-layered heterostructures are presented with a particular focus, for practical purposes, on the description of fast, accurate and robust techniques. The use of X-ray scattering metrology as a routinely working non-destructive testing method, particularly by using procedures simplifying the data-evaluation, is emphasized. The model-independent Fourier-inversion method applied to a reflectivity curve allows a fast determination of the individual layer thicknesses. We demonstrate the capability of this method by reporting X-ray reflectometry study on multilayered oxide structures, even when the number of the layers constitutive of the stack is not known a-priori. Fast Fourier transform-based procedure has also been employed successfully on high resolution X-ray diffraction profiles. A study of the reliability of the integral-breadth methods in diffraction line-broadening analysis applied to thin layers, in order to determine coherent domain sizes, is also reported. Examples from studies of oxides-based thin-layers heterostructures will illustrate these methods. In particular, X-ray scattering studies performed on high-k HfO{sub 2} and SrZrO{sub 3} thin-layers, a (GaAs/AlOx) waveguide, and a ZnO thin-layer are reported.

  1. Analysis of local concentration in stomach fold pattern by using abdominal X-ray CT image

    International Nuclear Information System (INIS)

    Watanabe, Shigeto; Hasegawa, Jun-ichi; Mekada, Yoshito; Mori, Kensaku; Nawano, Shigeru

    2004-01-01

    The paper presents a method for analysis of stomach folds pattern in abdominal X-ray CT images. Many stomach cancers have local concentration of folds at cancer lesions. Therefore, in stomach diagnosis, it is very important to evaluate quantitatively such fold concentration. In this paper, a method for calculation of concentration index for line figure on a curved surface is proposed first. Then, using this method a processing procedure for detection of stomach cancer from an abdominal X-ray CT image is developed. In the experiment using practical X-ray CT images, it is shown that by the proposed procedure, higher values of concentration index are obtained at cancer area. (author)

  2. Anthropometric and clinical profiles of post-bariatric patients submitted to procedures in plastic surgery.

    Science.gov (United States)

    Rosa, Simone Corrêa; Macedo, Jefferson Lessa Soares DE; Casulari, Luiz Augusto; Canedo, Lucas Ribeiro; Marques, João Vitor Almeida

    2018-01-01

    to evaluate the profile of patients submitted to post-bariatric plastic surgery at the North Wing Regional Hospital, Brasília, DF. we conducted a prospective, descriptive and analytical study of patients submitted to Roux-en-Y gastroplasty, and subsequently to plastic surgery, from January 2011 to December 2016. We assessed body mass index before gastroplasty and after surgery plastic surgery, postoperative complications and comorbidities. we studied 139 patients (130 women and nine men), with a mean age of 41 years, who underwent 233 operations. The mean BMI at the time of plastic surgery was 27.44kg/m2. The mean weight loss was 47.02kg and the mean maximum BMI was 45.17kg/m2. The mean time between bariatric surgery and plastic surgery was 42 months. The most important co-morbidities before plastic surgery were arterial hypertension (11.5%), arthropathy (5.4%), diabetes mellitus (5%) and metabolic syndrome (4.3%) (pprofile of post-bariatric patients who underwent plastic surgery was similar to that reported in the literature, except for the low rate of associated surgeries and postoperative complications. Plastic surgery in post-bariatric patients has led to an improvement in the quality of life in most of these patients.

  3. Usefulness of post-mortem ophthalmological endoscopy during forensic autopsy: a case report.

    Science.gov (United States)

    Tsujinaka, Masatake; Akaza, Kayoko; Nagai, Atsushi; Nakamura, Isao; Bunai, Yasuo

    2005-01-01

    Post-mortem intraocular findings in two autopsy cases with traumatic intracranial haemorrhage were obtained using an ophthalmological endoscope. The endoscopy results clearly revealed the presence of intraocular haemorrhages and papilledema caused by intracranial haemorrhage. Post-mortem ophthalmological endoscopy offers several benefits. First, post-mortem intraocular findings can be directly observed in corpses with post-mortem clouding of the cornea. Secondly, the endoscopy only requires a 0.9 mm incision in the sclera and does not require the removal of the eye from the corpse, a procedure that should be avoided for ethical and cosmetic reasons. Thus, post-mortem opthalmological endoscopy is a useful method for obtaining intraocular findings in autopsies.

  4. Accidental over-exposure from dental X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, B G [National Radiological Protection Board, Harwell (UK)

    1976-07-01

    A description is given of an unusual dental X-ray procedure which resulted in accidental over-exposure both to the dentist and to several of his patients when a short-circuit was present in newly-installed equipment. The short-circuit by-passed the exposure control and energized the tube for certain orientations of the X-ray tube. The dentist left the patients, who wore protective aprons, to initiate the exposure themselves, using the control button. Although the warning lights were on, the dentist was not present in the room during the exposure, and the over-exposures were only detected when the developed X-ray films were found to be completely blackened. A reconstruction of the procedure enabled estimates to be made of the dose equivalents to the dentist's body and to the skin of the head, the eyes and the gonads of the patients. The dentist had overlooked several of basic principles recommended in the Code of Practice for the Protection of Persons against Ionizing Radiations from Medical and Dental Use (1972). It is pointed out that incidents involving failure of dental equipment (usually the timer mechanism) are not infrequent.

  5. Necrotizing scleritis as a complication of cosmetic eye whitening procedure

    OpenAIRE

    Leung, Theresa G; Dunn, James P; Akpek, Esen K; Thorne, Jennifer E

    2013-01-01

    Background We report necrotizing scleritis as a serious complication of a cosmetic eye whitening procedure that involves the use of intraoperative and postoperative topical mitomycin C. Findings This is a single case report. A 59-year-old Caucasian male with a history of blepharitis status post uncomplicated LASIK refractive surgery reported chronic conjunctival hyperemia for 15 years prior to undergoing a cosmetic eye whitening procedure. He presented to our clinic 12 months after the cosmet...

  6. Soft X-ray Foucault test: A path to diffraction-limited imaging

    Science.gov (United States)

    Ray-Chaudhuri, A. K.; Ng, W.; Liang, S.; Cerrina, F.

    1994-08-01

    We present the development of a soft X-ray Foucault test capable of characterizing the imaging properties of a soft X-ray optical system at its operational wavelength and its operational configuration. This optical test enables direct visual inspection of imaging aberrations and provides real-time feedback for the alignment of high resolution soft X-ray optical systems. A first application of this optical test was carried out on a Mo-Si multilayer-coated Schwarzschild objective as part of the MAXIMUM project. Results from the alignment procedure are presented as well as the possibility for testing in the hard X-ray regime.

  7. A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

    International Nuclear Information System (INIS)

    Rana, V. K.; Rudin, S.; Bednarek, D. R.

    2016-01-01

    Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be

  8. A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Rana, V. K., E-mail: vkrana@buffalo.edu [Toshiba Stroke and Vascular Research Center, Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York 14203 (United States); Rudin, S., E-mail: srudin@buffalo.edu; Bednarek, D. R., E-mail: bednarek@buffalo.edu [Toshiba Stroke and Vascular Research Center, Departments of Radiology, Neurosurgery, Physiology and Biophysics, State University of New York at Buffalo, Buffalo, New York 14203 (United States)

    2016-09-15

    Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be

  9. Necrotizing scleritis as a complication of cosmetic eye whitening procedure.

    Science.gov (United States)

    Leung, Theresa G; Dunn, James P; Akpek, Esen K; Thorne, Jennifer E

    2013-02-22

    We report necrotizing scleritis as a serious complication of a cosmetic eye whitening procedure that involves the use of intraoperative and postoperative topical mitomycin C. This is a single case report. A 59-year-old Caucasian male with a history of blepharitis status post uncomplicated LASIK refractive surgery reported chronic conjunctival hyperemia for 15 years prior to undergoing a cosmetic eye whitening procedure. He presented to our clinic 12 months after the cosmetic eye whitening procedure with progressive bilateral necrotizing scleritis and scleral calcification. Chronic conjunctival hyperemia may prompt patients to seek surgical correction with cosmetic eye whitening procedures. However, conjunctival hyperemia secondary to tear deficiency and evaporative dry eye may predispose to poor wound healing. Serious complications including necrotizing scleritis may result from cosmetic eye whitening procedures and the use of topical mitomycin C.

  10. Cytogenetics of Post-Irradiation Mouse Leukaemia

    Energy Technology Data Exchange (ETDEWEB)

    Wald, N.; Pan, S.; Upton, A.; Brown, R. [Graduate School of Public Health, University of Pittsburgh, PA (United States); Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1969-11-15

    The interrelationship between radiation, cytogenetic abnormalities, and viruses in leukaemogenesis has been studied in the RF/Un mouse which develops a high incidence of granulocytic leukaemia on radiation exposure. A virus-like agent has been demonstrated in such leukaemic animals and the disease has been transmitted by passage of apparently acellular materials from irradiated primary animals to normal recipients. Pilot cytogenetic studies revealed consistent abnormal chromosome markers and modal shifts in both irradiated leukaemic animals and in non-irradiated animals developing leukaemia after passage injection. To define better the relationship between consistent bone-marrow chromosome aberrations and postirradiation primary and passaged leukaemia, 100 RF/Un mice were studied which were irradiated with 300 R of 250-kVp X-rays at 100 weeks of age and subsequently developed leukaemia. Eighty-seven had granulocytic leukaemia and in 72 of these, bone-marrow cytogenetic abnormalities were found. The distribution of-numerical and structural chromosome aberrations in 3225 cells studied are reviewed in derail. The correlation of specific aberrations to clinical and histopathologic findings has been attempted: Sequential passages of apparently cell-free material from the post-irradiation leukaemic mice into unirradiated RE/Un recipients and subsequent passages from leukaemic recipients were performed to observe the evolution of any initial chromosome markers and shifts in modal chromosome number in the passage generations. Two-hundred-thirty-six mice were inoculated with the material obtained either from primary post-irradiation leukaemic mice or from serially-passaged leukaemia cases. In the most extensive passaged line, 22 transfer generations containing 129 leukaemic mice were examined by clinical, histopathologic, -haematologic and cytogenetic procedures. Evolution of abnormal chromosome modes from 41 in the early passages to 39 chromosomes consistently after the 4

  11. Safe disposal of radioactive waste. Post-closure safety assessment of permanent repository in Novi han

    International Nuclear Information System (INIS)

    Mateeva, M.

    2007-01-01

    A presented material is the third part of the monograph with title 'Safe disposal of radioactive waste. Post-closure safety assessment of the permanent repository in Novi Han'. This part deals with review of the scenario selection procedure. The process system of permanent repository for radioactive waste is describing in details for different levels. Preliminary screening process of features, events and processes is presented here. Interaction matrixes for basic disposal system components are constructed. Final selection and grouping between the included features, events and processes is done. Selected and defined scenarios for post-closure safety assessment are presented too. Key words: post-closure safety assessment, scenario generation procedure, process system, process influence diagram, and interaction matrix

  12. FREY’S PROCEDURE- TO ANALYSE THE OUTCOME OF THIS PROCEDURE IN CHRONIC PANCREATITIS

    Directory of Open Access Journals (Sweden)

    Shilpa Mariappa Casaba

    2017-04-01

    Full Text Available BACKGROUND Chronic Pancreatitis (CP is a progressive inflammatory disease characterised by debilitating pain and pancreatic insufficiency. There is enormous personal and socio-economic impact on impairment of quality of life, inability to work and even shortening of life expectancy. Although, pancreaticoduodenectomy had been considered the standard surgical procedure for patients with CP because of its high post-op complications with exocrine and endocrine insufficiency, it is not preferred. This has led to a hybrid procedure described by Frey’s, which is used in our study for CP. We aim to analyse the short-term and long-term outcomes of Frey’s procedure at a tertiary care center in patients with chronic pancreatitis. MATERIALS AND METHODS A retrospective review of all CP patients who underwent Frey procedure were reviewed from January 2007-January 2016. Perioperative variables, short-term (30 days and long-term (3 years outcomes were reviewed. Data are frequency (% or mean. RESULTS A total of 97 patients underwent Frey’s procedure. A total of 72 (70.7% were men and 25 (29.3% were women. Mean age was 38 years (range 14-66 years. Indications for surgery included intractable pain (n=97, 100% and obstructive jaundice (n=4, 4.3%. 9 patients (32.6% were diabetic preoperatively. Concomitant procedures include biliary drainage procedure was done for 4 patients (4.3%, i.e. choledochojejunostomy and splenectomy for 2 patients (2.1%, cholecystectomy (n=6, 6%. Short-term outcomes include surgical site infection (n=10, 10%, pancreatic leak (n=6, 5.82% and 2 patients required reoperation for bleeding and no mortality (30 days, diabetic ketoacidosis (n=2, 2%. Pancreatic carcinoma was detected in 3 (2.1% patients. Long-term outcomes include pain free status (n=80, 86.9%, median follow-up of 3 years. Redo pancreatic procedure was performed in 1 (4.3% for anastomotic leak. CONCLUSION Frey’s procedure is a safe and effective pain palliative option for CP

  13. Remission of type 2 diabetes mellitus after bariatric surgery - comparison between procedures.

    Science.gov (United States)

    Fernández-Soto, María L; Martín-Leyva, Ana; González-Jiménez, Amalia; García-Rubio, Jesús; Cózar-Ibáñez, Antonio; Zamora-Camacho, Francisco J; Leyva-Martínez, María S; Jiménez-Ríos, Jose A; Escobar-Jiménez, Fernándo

    2017-01-01

    We aimed to assess the mid-term type 2 diabetes mellitus recovery patterns in morbidly obese patients by comparing some relevant physiological parameters of patients of bariatric surgery between two types of surgical procedures: mixed (roux-en-Y gastric bypass and biliopancreatic diversion) and restrictive (sleeve gastrectomy). This is a prospective and observational study of co-morbid, type 2 diabetes mellitus evolution in 49 morbidly obese patients: 37 underwent mixed surgery procedures and 12 a restrictive surgery procedure. We recorded weight, height, body mass index, and glycaemic, lipid, and nutritional blood parameters, prior to procedure, as well as six and twelve months post-operatively. In addition, we tested for differences in patient recovery and investigated predictive factors in diabetes remission. Both glycaemic and lipid profiles diminished significantly to healthy levels by 6 and 12 months post intervention. Type 2 diabetes mellitus showed remission in more than 80% of patients of both types of surgical procedures, with no difference between them. Baseline body mass index, glycated haemoglobin, and insulin intake, among others, were shown to be valuable predictors of diabetes remission one year after the intervention. The choice of the type of surgical procedure did not significantly affect the remission rate of type 2 diabetes mellitus in morbidly obese patients. (Endokrynol Pol 2017; 68 (1): 18-25).

  14. The use of x-ray imaging technology in cargo inspection

    International Nuclear Information System (INIS)

    Palgan, Renato D.

    2009-01-01

    The aftermath of the September 11,2001 terrorist attack in the United States has brought a significant change in the conduct of trade and commerce among nations. The introduction on non-intrusive cargo inspection equipment, most x-ray and gamma ray scanners, among customs administrations worldwide has been widely employed and incorporated in their respective cargo examination procedures as part of their security initiative to deter terrorist threats. In compliance with our international commitment and agreement passed by the World Customs Organization which required the use of modern technology in cargo inspection, the Bureau of Customs had acquired 30 units of container x-ray scanners in 2006 from China that became operational in 2007 and the acquisition of which was guided by the following objectives: maximize collection of government revenues,facilitate trade and commerce, prevent smuggling, and safeguard the public and environment against the entry of hazardous and harmful substance. In this light, this paper discusses the brief background of the non-intrusive container inspection system project of the Bureau of Customs, an overview of the technical features of x-ray imaging technology acquired, the procedures in the application of x-ray inspection in containerized cargo, the radiation safety infrastructures and considerations, and a review of some major accomplishments after its two years of existence. (author)

  15. X-ray fluorescence analysis of Fe - Ni - Mo systems

    International Nuclear Information System (INIS)

    Belyaev, E.E.; Ershov, A.V.; Mashin, A.I.; Mashin, N.I.; Rudnevskij, N.K.

    1998-01-01

    Procedures for the X-ray fluorescence determination of the composition and thickness of Fe - Ni - Mo thin films and the concentration of elements in thick films of the Fe - Ni - Mo alloy are developed [ru

  16. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    International Nuclear Information System (INIS)

    U-King-Im, J.M.; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H.

    2004-01-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging

  17. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, J.M. E-mail: jhg21@cam.ac.uk; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H

    2004-04-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging.

  18. The pre-trial procedures and principles of the International Criminal ...

    African Journals Online (AJOL)

    The pre-trial procedures and principles of the International Criminal Court. ... the accused persons were done ex-post facto and devoid of any country's law. ... Against this background, this paper attempts to put the ambiguities aside and ...

  19. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins

    International Nuclear Information System (INIS)

    Buecker, A.; Gross-Fengels, W.; Haage, P.; Huppert, P.; Landwehr, P.; Loose, R.; Reimer, P.; Tacke, J.; Vorwerk, D.; Fischer, J.

    2012-01-01

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  20. X-ray mirror development and testing for the ATHENA mission

    Science.gov (United States)

    Della Monica Ferreira, Desiree; Jakobsen, Anders C.; Massahi, Sonny; Christensen, Finn E.; Shortt, Brian; Garnæs, Jørgen; Torras-Rosell, Antoni; Krumrey, Michael; Cibik, Levent; Marggraf, Stefanie

    2016-07-01

    This study reports development and testing of coatings on silicon pore optics (SPO) substrates including pre and post coating characterisation of the x-ray mirrors using Atomic Force Microscopy (AFM) and X-ray reflectometry (XRR) performed at the 8 keV X-ray facility at DTU Space and with synchrotron radiation in the laboratory of PTB at BESSY II. We report our findings on surface roughness and coating reflectivity of Ir/B4C coatings considering the grazing incidence angles and energies of ATHENA and long term stability of Ir/B4C, Pt/B4C, W/Si and W/B4C coatings.

  1. Recent developments in airborne gamma ray surveying

    International Nuclear Information System (INIS)

    Grasty, Robert L.

    1999-01-01

    Standardized procedures have been developed for converting airborne gamma ray measurements to ground concentrations of potassium, uranium and thorium. These procedures make use of an airborne calibration range whose ground concentrations should be measured with a calibrated portable spectrometer rather than by taking geochemical samples. Airborne sensitivities and height attenuation coefficients are normally determined from flights over the calibration range but may not be applicable in mountainous areas. Mathematical techniques have been now developed to reduce statistical noise in the airborne measurements by utilizing up to 256 channels of spectral information. (author)

  2. X-ray scatter signatures for enhanced breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kidane, Ghirmay; Speller, Robert; Royle, Gary [Medical Physics and Bioengineering Department, University College Landon, 11-20 Capper Street, London WC1E 6JA (United Kingdom)

    1999-12-31

    Conventional mammographic imaging suffers from a low specificity. The main cause is the small difference in the x-ray attenuation properties of healthy and diseased tissue leading to poor contrast in the image. It has been observed that additional information on breast tissue type can be obtained from x-ray diffraction effects. A study of excised normal and neoplastic breast tissue samples using x-ray diffraction apparatus has been observed that significant differences exist in the measured spectra between carcinoma and healthy tissue adjacent to the carcinoma. Such a difference allows tissue type to be characterised according to is diseased state. Furthermore the information can be applied to improve diagnosis. It is proposed that collection and analysis of the scattered x-rays present during a mammographic procedure can supply the additional information and be used to improve the image contrast. The ultimate aim of the project is to improve the specificity of x-ray mammography. (authors) 10 refs., 3 figs.

  3. Hip arthroscopy protocol: expert opinions on post-operative weight bearing and return to sports guidelines.

    Science.gov (United States)

    Rath, Ehud; Sharfman, Zachary T; Paret, Matan; Amar, Eyal; Drexler, Michael; Bonin, Nicolas

    2017-01-01

    The objectives of this study are to survey the weight-bearing limitation practices and delay for returning to running and impact sports of high volume hip arthroscopy orthopedic surgeons. The study was designed in the form of expert survey questionnaire. Evidence-based data are scares regarding hip arthroscopy post-operative weight-bearing protocols. An international cross-sectional anonymous Internet survey of 26 high-volume hip arthroscopy specialized surgeons was conducted to report their weight-bearing limitations and rehabilitation protocols after various arthroscopic hip procedures. The International Society of Hip Arthroscopy invited this study. The results were examined in the context of supporting literature to inform the studies suggestions. Four surgeons always allow immediate weight bearing and five never offer immediate weight bearing. Seventeen surgeons provide weight bearing depending on the procedures performed: 17 surgeons allowed immediate weight bearing after labral resection, 10 after labral repair and 8 after labral reconstruction. Sixteen surgeons allow immediate weight bearing after psoas tenotomy. Twenty-one respondents restrict weight bearing after microfracture procedures for 3-8 weeks post-operatively. Return to running and impact sports were shorter for labral procedures and bony procedures and longer for cartilaginous and capsular procedures. Marked variability exists in the post-operative weight-bearing practices of hip arthroscopy surgeons. This study suggests that most surgeons allow immediate weight bearing as tolerated after labral resection, acetabular osteoplasty, chondroplasty and psoas tenotomy. For cartilage defect procedures, 6 weeks or more non-weight bearing is suggested depending on the area of the defect and lateral central edge angle. Delayed return to sports activities is suggested after microfracture procedures. The level of evidence was Level V expert opinions.

  4. PHMC post-NPH emergency response training

    International Nuclear Information System (INIS)

    Conrads, T.J.

    1997-01-01

    This document describes post-Natural Phenomena Hazard (NPH) emergency response training that was provided to two teams of Project Hanford Management Contractors (PHMC) staff that will be used to assess potential structural damage that may occur as a result of a significant natural phenomena event. This training supports recent plans and procedures to use trained staff to inspect structures following an NPH event on the Hanford Site

  5. PHMC post-NPH emergency response training

    Energy Technology Data Exchange (ETDEWEB)

    Conrads, T.J.

    1997-04-08

    This document describes post-Natural Phenomena Hazard (NPH) emergency response training that was provided to two teams of Project Hanford Management Contractors (PHMC) staff that will be used to assess potential structural damage that may occur as a result of a significant natural phenomena event. This training supports recent plans and procedures to use trained staff to inspect structures following an NPH event on the Hanford Site.

  6. Production of hollow atoms by high brightness x-ray sources and its applications

    International Nuclear Information System (INIS)

    Moribayashi, Kengo

    2004-01-01

    We study x-ray emissions from the (multi-)inner-shell states and hollow atoms of Si ions excited by high intensity x-ray sources. It is found that the x-ray number from multi-inner-shell excited states (1s 2 2s 2 2p k 3s 2 3p 2 , k=1-4) and hollow atoms (1s 2 2s 2 3p 2 ) is affected greatly by the high intensity short-pulse x-rays and little by weak intensity post-long pulse x-rays. The ratio of the x-ray intensities from hollow atoms to those from the multi-inner-shell excited states becomes almost independent of the pulses and dependent on the intensities of x-ray sources. This ratio may be used for the measurement of intensities of high intensity short pulse x-ray sources. (author)

  7. Reactivity of Cu with poly(tetrafluoroethylene) and poly(vinyl chloride): Effect of pre- and post-metallization modification on the metal/polymer interface

    International Nuclear Information System (INIS)

    Perry, C.C.; Torres, J.; Carlo, S.R.; Fairbrother, D. Howard

    2002-01-01

    The reactivity of Cu with poly(tetrafluoroethylene) (PTFE) and poly(vinylchloride) (PVC) during thermal evaporation, as well as the effect of pre- and post-metallization Ar + ion and x-ray mediated surface modification treatments on the metal/polymer interface, have been studied using in situ x-ray photoelectron spectroscopy (XPS) and ex situ atomic force microscopy (AFM). During thermal evaporation, copper was unreactive on PTFE but reacted with PVC to form CuCl. Pretreatment of PTFE or PVC surfaces by Ar + ion or x-ray irradiation did not modify the chemical reactivity of the polymer surface during subsequent Cu deposition, although significant morphological changes were observed on PTFE by AFM. In contrast, post-metallization modification of the Cu/PTFE interface by Ar + ion or x-ray irradiation lead to the production of CuF 2 , and increased the yield of CuCl in the Cu/PVC system. In either the Cu/PTFE or Cu/PVC systems, the maximum concentration of copper halide formed and dependence upon treatment time was found to be similar for either Ar + ion or x-ray irradiation post-metallization treatment strategies, suggesting a common reaction mechanism

  8. Trends in the electronic X-ray image formation and processing

    International Nuclear Information System (INIS)

    Meyer-Ebrecht, D.; Spiesberger, W.

    1976-01-01

    A report is given on the technological progress in components for the electronic imaging and reproduction in X-ray diagnostics which could enable the partial replacement of radiophotography. Furthermore, electronic post processing methods, in particular in tomography, are reviewed. (ORU) [de

  9. Food Safety Impacts from Post-Harvest Processing Procedures of Molluscan Shellfish.

    Science.gov (United States)

    Baker, George L

    2016-04-18

    Post-harvest Processing (PHP) methods are viable food processing methods employed to reduce human pathogens in molluscan shellfish that would normally be consumed raw, such as raw oysters on the half-shell. Efficacy of human pathogen reduction associated with PHP varies with respect to time, temperature, salinity, pressure, and process exposure. Regulatory requirements and PHP molluscan shellfish quality implications are major considerations for PHP usage. Food safety impacts associated with PHP of molluscan shellfish vary in their efficacy and may have synergistic outcomes when combined. Further research for many PHP methods are necessary and emerging PHP methods that result in minimal quality loss and effective human pathogen reduction should be explored.

  10. X-Ray Optics at NASA Marshall Space Flight Center

    Science.gov (United States)

    O'Dell, Stephen L.; Atkins, Carolyn; Broadway, David M.; Elsner, Ronald F.; Gaskin, Jessica A.; Gubarev, Mikhail V.; Kilaru, Kiranmayee; Kolodziejczak, Jeffery J.; Ramsey, Brian D.; Roche, Jacqueline M.; hide

    2015-01-01

    NASA's Marshall Space Flight Center (MSFC) engages in research, development, design, fabrication, coating, assembly, and testing of grazing-incidence optics (primarily) for x-ray telescope systems. Over the past two decades, MSFC has refined processes for electroformed-nickel replication of grazing-incidence optics, in order to produce high-strength, thin-walled, full-cylinder x-ray mirrors. In recent years, MSFC has used this technology to fabricate numerous x-ray mirror assemblies for several flight (balloon, rocket, and satellite) programs. Additionally, MSFC has demonstrated the suitability of this technology for ground-based laboratory applications-namely, x-ray microscopes and cold-neutron microscopes and concentrators. This mature technology enables the production, at moderately low cost, of reasonably lightweight x-ray telescopes with good (15-30 arcsecond) angular resolution. However, achieving arcsecond imaging for a lightweight x-ray telescope likely requires development of other technologies. Accordingly, MSFC is conducting a multi-faceted research program toward enabling cost-effective production of lightweight high-resolution x-ray mirror assemblies. Relevant research topics currently under investigation include differential deposition for post-fabrication figure correction, in-situ monitoring and control of coating stress, and direct fabrication of thin-walled full-cylinder grazing-incidence mirrors.

  11. Material density measurements from dynamic flash x-ray radiographs using axisymmetric tomography

    International Nuclear Information System (INIS)

    Fugelso, E.

    1981-03-01

    The axisymmetric version of the tomographic x-ray reconstruction procedures has been utilized to determine the material density for the impact of a cylinder on a steel plate. Derivations of the reconstruction algorithms relating x-ray radiographic intensities to the material densities are presented. Effects of noise, point spread functions, and motion blur are minimized

  12. Energy dispersive X-ray analysis in the electron microscope

    CERN Document Server

    Bell, DC

    2003-01-01

    This book provides an in-depth description of x-ray microanalysis in the electron microscope. It is sufficiently detailed to ensure that novices will understand the nuances of high-quality EDX analysis. Includes information about hardware design as well as the physics of x-ray generation, absorption and detection, and most post-detection data processing. Details on electron optics and electron probe formation allow the novice to make sensible adjustments to the electron microscope in order to set up a system which optimises analysis. It also helps the reader determine which microanalytical me

  13. Post-16 update

    Science.gov (United States)

    1999-07-01

    (post16) Faces of Physics To study a physics course post-16 is take out an option on your future. But physics itself is very varied, and so is what you might do with it. It seems right that post-16 physics courses reflect important aspects of this variety. Physics varies with why people do it. As reliable knowledge, physics is often essential to making things happen. This is physics as feeding into technology, and quite often feeding off technology. The human urge here is the urge to create things that work. It drives individual inventors; it drives large teams in multinational companies. At the opposite end of this spectrum is physics driven by curiosity, by the urge to find out. The stock examples are the grand discoveries from the expansion of the universe to the discovery of the nucleus of atoms. But the physicist's curiosity is often on a more detailed, even finicky scale: how exactly do the molecules of this polymer respond to stress?; just how do ions implanted in this material modify its conductivity? It is clear to me that a decent post-16 physics course must respect and reflect both. This is by no means a matter of `basic laws and their applications'. It is a matter of recognizing two fundamental interests, in doing and in explaining, and of recognizing that they are at once closely interdependent and worlds apart. Ideas in physics are also not of one kind. One opposition is the idea of describing Nature in terms of deterministic physical laws, as against describing Nature as the predictable outcome of probabilistic behaviour `underneath'. The first has gripped the Western imagination since at least the time of Descartes. The second has increasingly come to the fore, especially in thermodynamics with the idea that we can only make processes work by fixing the circumstances so that uncaring atoms and molecules happen by chance to do what we want. Now in quantum theory both ideas - determinism and randomness - co-exist. Post-16 physics courses are not in

  14. Survey of post-gamma-ray colony-forming ability, DNA metabolism and oncogene status in non-malignant fibroblast strains from cancer-prone families and individual cancer patients

    International Nuclear Information System (INIS)

    Paterson, M.C.; Aubin, R.A.; Fourney, R.M.; Mirzayans, R.

    1989-01-01

    The in vitro radiobiological studies described here have focused on highly selected individuals comprising some of the most likely cases of predisposition to radiogenic cancer ascertained to date. Our results argue against the existence, within the general population, of quantitatively significant subgroups sensitive to the carcinogenic effects of ubiquitous low-level radiation. In fact, of the forty-six cancer-susceptible conditions examined, only four (i.e. members of the cancer-prone lineage in two kindreds and two isolated patients), exhibited abnormal cellular response to γ-rays in vitro. These findings indicate that in this unprecedented collection of high cancer risk conditions, the incidence of abnormal radiation cytotoxicity is only about two-fold above that found in a randomly selected group of age-matched healthy subjects (i.e, about 9% [4/46 conditions] versus about 5% [1/21 volunteers]). This interpretation of the data assumes, however, that the post-γ-ray CFA assay performed on cultured dermal fibroblasts is a reliable and sensitive indicator of the donor's susceptibility to develop radiogenic cancer, irrespective of the anatomical site or histological type of the tumour(s). (author)

  15. Imaging evaluation of post pancreatic surgery

    International Nuclear Information System (INIS)

    Scialpi, Michele; Scaglione, Mariano; Volterrani, Luca; Lupattelli, Luciano; Ragozzino, Alfonso; Romano, Stefania; Rotondo, Antonio

    2005-01-01

    The role of several imaging techniques in patients submitted to pancreatic surgery with special emphasis to single-slice helical computed tomography (CT) and multidetector-row CT (MDCT) was reviewed. Several surgical options may be performed such as Whipple procedure, distal pancreatectomy, central pancreatectomy, and total pancreatectomy. Ultrasound examination may be used to detect peritoneal fluid in the early post-operative period as well as lesion recurrence in long-term follow-up. Radiological gastrointestinal studies has a major role in evaluation of intestinal functionality. In spite of the advent of other imaging modalities, CT is the most effective after pancreatic surgery. On post-operative CT, the most common findings were small fluid peritoneal or pancreatic collections, stranding of the mesenteric fat with perivascular cuffing, reactive adenopathy and pneumobilia. In addition, CT may demonstrate early (leakage of anastomosis, pancreatico-jejunal fistula, haemorrage, acute pancreatitis of the remnant pancreas, peritonitis), and late (chronic fistula, abscess, aneurysms, anastomotic bilio-digestive stenosis, perianastomotic ulcers, biloma, and intra-abdominal bleeding) surgical complications. In the follow-up evaluation, CT may show tumor recurrence, liver and lymph nodes metastasis. Magnetic resonance may be used as alternative imaging modality to CT, when renal insufficiency or contrast sensitivity prevents the use of iodinated i.v. contrast material or when the biliary tree study is primarily requested. The knowledge of the type of surgical procedures, the proper identification of the anastomoses as well as the normal post-operative imaging appearances are essential for an accurate detection of the complications and recurrent disease

  16. Imaging evaluation of post pancreatic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Scialpi, Michele [Department of Radiology, ' Santissima Annunziata' Hospital, Via Bruno 1, I-74100 Taranto (Italy)]. E-mail: michelescialpi@libero.it; Scaglione, Mariano [Department of Radiology, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Volterrani, Luca [Institute of Radiology, University of Siena, I-53100 Siena (Italy); Lupattelli, Luciano [Institute of Radiology, University of Perugia, I-06122 Perugia (Italy); Ragozzino, Alfonso [Department of Radiology, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Romano, Stefania [Department of Radiology, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Rotondo, Antonio [Section of Radiology, Department ' Magrassi-Lanzara' , Second University, I-80138 Naples (Italy)

    2005-03-01

    The role of several imaging techniques in patients submitted to pancreatic surgery with special emphasis to single-slice helical computed tomography (CT) and multidetector-row CT (MDCT) was reviewed. Several surgical options may be performed such as Whipple procedure, distal pancreatectomy, central pancreatectomy, and total pancreatectomy. Ultrasound examination may be used to detect peritoneal fluid in the early post-operative period as well as lesion recurrence in long-term follow-up. Radiological gastrointestinal studies has a major role in evaluation of intestinal functionality. In spite of the advent of other imaging modalities, CT is the most effective after pancreatic surgery. On post-operative CT, the most common findings were small fluid peritoneal or pancreatic collections, stranding of the mesenteric fat with perivascular cuffing, reactive adenopathy and pneumobilia. In addition, CT may demonstrate early (leakage of anastomosis, pancreatico-jejunal fistula, haemorrage, acute pancreatitis of the remnant pancreas, peritonitis), and late (chronic fistula, abscess, aneurysms, anastomotic bilio-digestive stenosis, perianastomotic ulcers, biloma, and intra-abdominal bleeding) surgical complications. In the follow-up evaluation, CT may show tumor recurrence, liver and lymph nodes metastasis. Magnetic resonance may be used as alternative imaging modality to CT, when renal insufficiency or contrast sensitivity prevents the use of iodinated i.v. contrast material or when the biliary tree study is primarily requested. The knowledge of the type of surgical procedures, the proper identification of the anastomoses as well as the normal post-operative imaging appearances are essential for an accurate detection of the complications and recurrent disease.

  17. 20 CFR Appendix A to Part 718 - Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays)

    Science.gov (United States)

    2010-04-01

    ... Interpretation of Chest Roentgenograms (X-Rays) A Appendix A to Part 718 Employees' Benefits EMPLOYMENT STANDARDS... 718—Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays) The following... procedures are used in administering and interpreting X-rays and that the best available medical evidence...

  18. Imaging guided interventional procedures in paediatric uroradiology--a case based overview

    Energy Technology Data Exchange (ETDEWEB)

    Riccabona, M. E-mail: michael.riccabona@kfunigraz.ac.at; Sorantin, E.; Hausegger, K

    2002-08-01

    Objective: To describe the potential and application of interventional image guided procedures in the paediatric urinary tract. Patients and methods: The different techniques are illustrated using case reports. The examples comprise established indications such as percutaneous nephrostomy for compromised kidneys in obstructive uropathy and infection, sonographic guided renal biopsy including monitoring or treatment of complications after biopsy, and evaluation and balloon dilatation of childhood renal artery stenosis. There are new applications such as treatment of stenosis in cutaneous ureterostomy or sonographically guided catheterism for deployment of therapeutic agents. Results: Generally, the procedures are safe and successful. However, complications may occur, and peri-/post-interventional monitoring is mandatory to insure early detection and adequate management. Sometimes additional treatment such as percutaneous embolisation of a symptomatic post biopsy arterio-venous fistula, or a second biopsy for recurrent disease may become necessary. Conclusion: Imaging guided interventional procedures are performed successfully in a variety of diseases of the paediatric urinary tract. They can be considered a valuable additional modality throughout infancy and childhood.

  19. Imaging guided interventional procedures in paediatric uroradiology--a case based overview

    International Nuclear Information System (INIS)

    Riccabona, M.; Sorantin, E.; Hausegger, K.

    2002-01-01

    Objective: To describe the potential and application of interventional image guided procedures in the paediatric urinary tract. Patients and methods: The different techniques are illustrated using case reports. The examples comprise established indications such as percutaneous nephrostomy for compromised kidneys in obstructive uropathy and infection, sonographic guided renal biopsy including monitoring or treatment of complications after biopsy, and evaluation and balloon dilatation of childhood renal artery stenosis. There are new applications such as treatment of stenosis in cutaneous ureterostomy or sonographically guided catheterism for deployment of therapeutic agents. Results: Generally, the procedures are safe and successful. However, complications may occur, and peri-/post-interventional monitoring is mandatory to insure early detection and adequate management. Sometimes additional treatment such as percutaneous embolisation of a symptomatic post biopsy arterio-venous fistula, or a second biopsy for recurrent disease may become necessary. Conclusion: Imaging guided interventional procedures are performed successfully in a variety of diseases of the paediatric urinary tract. They can be considered a valuable additional modality throughout infancy and childhood

  20. Neurosurgical procedures in Jehovah's Witnesses: the Tema experience.

    Science.gov (United States)

    Andrews, N B

    2009-05-01

    On account of religious reasons, Jehovah Witnesses do not accept blood or blood products; occasionally, they accept reinfusion of autologous blood via a cell saver during surgery. The aim of this study was to document the demographics of Jehovah Witnesses undergoing neurosurgical procedures, the neurosurgical procedures undertaken in Jehovah Witnesses and to evaluate the complications of the procedures. A retrospective audit of the medical records of all Jehovah's Witnesses who underwent neurosurgical procedures at our institution, from January 1st 2000 to December 31st 2006, was carried out. The parameters investigated included demographics, pre and post operative diagnosis, type of neurosurgical procedure and complications. Nineteen patients (fifteen male, four female; male/female 3.8:1) constituted the series. The mean age was 45.8 (range: 20-65) years. A total of 21 procedures were performed; intracranial surgery (33%), spinal surgery (67%). No autotransfusion of blood was given. Lumbar laminectomy for stenosis was the commonest spine procedure, ten (71.4%); craniotomy for tumor excision was the commonest intracranial procedure, six (85.7%). With respect to the whole series, the morbidity rate was 4.7% and the mortality rate was 4.7%; both were from intracranial surgery. It is possible to perform certain types of neurosurgical procedures in Jehovah's Witnesses without increasing the mortality and morbidity rate.

  1. Frequency of medical and dental x-ray examinations in the UK. 1997/98

    International Nuclear Information System (INIS)

    Tanner, R.; Wall, B.; Shrimpton, P.

    2000-12-01

    A survey has been performed to assess the numbers of all types of radiological x-ray examination conducted in the UK during the period from April 1997 to March 1998. The survey covers all diagnostic and interventional procedures using x-rays for medical and dental purposes, both within and outside the National Health Service (NHS), but excludes a detailed analysis of magnetic resonance imaging (MRI), ultrasound and nuclear medicine. This is the first such national survey conducted by NRPB since 1983. The results provide a current picture of the pattern of medical x-ray imaging practice in the UK and will allow revised estimates to be made of the collective dose to the population from these procedures. The survey has utilised detailed information available from radiology management systems at a selected sample of 38 English NHS trusts. The different classifications of x-ray procedure have been re-arranged into 62 standardised categories based on anatomical location and whether they were conventional, computed tomography (CT) or interventional procedures. Extrapolation of the sample data to the whole of England was carried out using broad NHS radiology statistics (KH12 returns) for the period of the survey from the Department of Health. Additional data have been obtained covering NHS radiology practice in Wales and Northern Ireland and also for x-ray imaging practice outside NHS hospitals such as that performed in independent hospitals and by dentists and chiropractors. Results are presented giving the annual numbers and relative frequencies of x-ray examinations in the 62 categories and the contributions from radiology practice outside NHS hospitals and from the whole of the UK. Altogether, about 41.5 million medical and dental x-ray examinations were conducted in the UK in 1997/98, corresponding to 704 examinations per 1000 inhabitants. The increase since 1983 for medical examinations conducted in NHS hospitals has just kept pace with the increase in population

  2. Precise Alignment and Permanent Mounting of Thin and Lightweight X-ray Segments

    Science.gov (United States)

    Biskach, Michael P.; Chan, Kai-Wing; Hong, Melinda N.; Mazzarella, James R.; McClelland, Ryan S.; Norman, Michael J.; Saha, Timo T.; Zhang, William W.

    2012-01-01

    To provide observations to support current research efforts in high energy astrophysics. future X-ray telescope designs must provide matching or better angular resolution while significantly increasing the total collecting area. In such a design the permanent mounting of thin and lightweight segments is critical to the overall performance of the complete X-ray optic assembly. The thin and lightweight segments used in the assemhly of the modules are desigued to maintain and/or exceed the resolution of existing X-ray telescopes while providing a substantial increase in collecting area. Such thin and delicate X-ray segments are easily distorted and yet must be aligned to the arcsecond level and retain accurate alignment for many years. The Next Generation X-ray Optic (NGXO) group at NASA Goddard Space Flight Center has designed, assembled. and implemented new hardware and procedures mth the short term goal of aligning three pairs of X-ray segments in a technology demonstration module while maintaining 10 arcsec alignment through environmental testing as part of the eventual design and construction of a full sized module capable of housing hundreds of X-ray segments. The recent attempts at multiple segment pair alignment and permanent mounting is described along with an overview of the procedure used. A look into what the next year mll bring for the alignment and permanent segment mounting effort illustrates some of the challenges left to overcome before an attempt to populate a full sized module can begin.

  3. 75 FR 1616 - Post-2010 Resource Pool, Pick-Sloan Missouri Basin Program-Eastern Division

    Science.gov (United States)

    2010-01-12

    ... Allocation for the new customer was calculated using the Procedures. As defined in the Post-1985 Marketing..., a Federal power marketing agency of the Department of Energy (DOE), hereby announces the Post-2010... need to withdraw power from existing customers. The Final Power Allocation is published to show Western...

  4. High urinary flow in women with stress incontinence: corrected flow-age nomogram evaluation after a transobturator tape procedure.

    Science.gov (United States)

    Kitagawa, Yasuhide; Narimoto, Kazutaka; Urata, Satoko; Kawaguchi, Shohei; Kuribayashi, Masato; Namiki, Mikio

    2016-07-01

    We noninvasively compared urinary flow in both pre- and post-transobturator tape (TOT) procedures in stress urinary incontinence (SUI) patients using previously reported corrected flow-age nomograms in healthy women. This retrospective cohort study included patients who underwent a successful TOT procedure to treat SUI. Non-instrumented uroflowmetry was performed before and 3 months after surgery. Corrected maximum flow rate (cQmax) and average flow rate (cQave) were calculated using Qmax/√voided volume (VV) and Qave/√VV respectively. The ratio of corrected flow to age-adjusted corrected flow in healthy women was calculated in each patient. Each parameter was compared against pre-TOT and 3-months post-TOT values. Sixty-two patients were eligible for study inclusion. All urinary flow parameters were significantly higher pre-TOT than at 3 months post-TOT. The number of patients with cQmax and cQave over mean flow-age nomogram, compared with healthy women, before the TOT procedure decreased 3 months post-TOT; however, in many patients, cQmax and cQave were higher than in the corrected flow-age nomogram post-TOT. No significant difference in the ratio of cQmax to age-adjusted cQmax between pre- and post-TOT in the normal urinary flow group was observed, but significantly decreased in the high urinary flow group 3 months after TOT. Urinary flow rates were higher in SUI patients compared with age-matched controls and successful TOT procedures normalized urinary flows in patients with high urinary flow. A simple evaluation of urinary flow using a corrected flow-age nomogram may be clinically useful in SUI patients.

  5. Suppressing effect of antimutagenic flavorings on chromosome aberrations induced by UV-light or X-rays in cultured Chinese hamster cells

    International Nuclear Information System (INIS)

    Sasaki, Yu.F.; Imanishi, Hisako; Watanabe, Mie; Ohta, Toshihiro; Shirasu

    1990-01-01

    Chromosome aberrations induces by UV-light or X-rays were suppressed by the post-treatment with antimutagenic flavorings, such as anisaldehyde, cinnamaldehyde, coumarin, and vanillin. UV- or X-ray-irradiated surviving cells increased in the presence of each flavouring. X-ray-induced breakage-type and exchange-type chromosome aberrations were suppressed by the vanillin treatment in the G 1 phase of the cell cycle and a greater decrease in the number of X-ray-induced chromosome aberrations during G 1 holding was observed in the presence of vanillin. Furthermore, a greater decrease in the number of X-ray-induced DNA single-strand breaks was observed in the presence of vanillin. Treatment with vanillin in the G 2 phase suppressed UV-and X-ray-induced breakage-type but not exchange-type chromosome aberrations. The suppression of breakage-type aberrations was assumed to be due to a modification of the capability of the post-replicational repair of DNA double-strand breaks. (author). 28 refs.; 5 figs.; 6 tabs

  6. Preparation of exposures charts for X-ray tubes

    International Nuclear Information System (INIS)

    Zoofan, B.

    1988-01-01

    An exposure chart is a fundamental graph which provides guidance of the exposure conditions in relation to the thickness for a given specimen. It must be prepared specially for the X-ray unit and the type of the film to be used. Although exposure charts are available for each particular X-ray tube from its manufacturer, individual radiographic laboratory should be able to prepare its own exposure charts in a precise manner. Here a typical procedure to prepare such a chart is provided in a practical way with some necessary recommendations

  7. Feasibility study for the in vivo measurement of lead in bone using L-x-ray fluorescence

    International Nuclear Information System (INIS)

    Wielopolski, L.; Slatkin, D.N.; Vartsky, D.; Ellis, K.J.; Cohn, S.H.

    1980-01-01

    Lead deposits in bone were detected by x-ray fluorescence using x-rays from either a 125 I or a 109 Cd source. Measurements were taken from tibia in intact human legs, post-mortem. On the basis of preliminary measurements, it was concluded that an exposure of one rad is adequate for determination of lead in bone. Both the advantages and the disadvantages of L-x-rays, used in the technique developed for this study, are compared with those of K-x-rays

  8. Improving Nanofiber Membrane Characteristics and Membrane Distillation Performance of Heat-Pressed Membranes via Annealing Post-Treatment

    Directory of Open Access Journals (Sweden)

    Minwei Yao

    2017-01-01

    Full Text Available Electrospun membranes are gaining interest for use in membrane distillation (MD due to their high porosity and interconnected pore structure; however, they are still susceptible to wetting during MD operation because of their relatively low liquid entry pressure (LEP. In this study, post-treatment had been applied to improve the LEP, as well as its permeation and salt rejection efficiency. The post-treatment included two continuous procedures: heat-pressing and annealing. In this study, annealing was applied on the membranes that had been heat-pressed. It was found that annealing improved the MD performance as the average flux reached 35 L/m2·h or LMH (>10% improvement of the ones without annealing while still maintaining 99.99% salt rejection. Further tests on LEP, contact angle, and pore size distribution explain the improvement due to annealing well. Fourier transform infrared spectroscopy and X-ray diffraction analyses of the membranes showed that there was an increase in the crystallinity of the polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP membrane; also, peaks indicating the α phase of polyvinylidene fluoride (PVDF became noticeable after annealing, indicating some β and amorphous states of polymer were converted into the α phase. The changes were favorable for membrane distillation as the non-polar α phase of PVDF reduces the dipolar attraction force between the membrane and water molecules, and the increase in crystallinity would result in higher thermal stability. The present results indicate the positive effect of the heat-press followed by an annealing post-treatment on the membrane characteristics and MD performance.

  9. Residual stress effects in LMFBR fracture assessment procedures

    International Nuclear Information System (INIS)

    Hooton, D.G.

    1984-01-01

    Two post-yield fracture mechanics methods, which have been developed into fully detailed failure assessment procedures for ferritic structures, have been reviewed from the point of view of the manner in which as-welded residual stress effects are incorporated, and comparisons then made with finite element and theoretical models of centre-cracked plates containing residual/thermal stresses in the form of crack-driving force curves. Applying the procedures to austenitic structures, comparisons are made in terms of failure assessment curves and it is recommended that the preferred method for the prediction of critical crack sizes in LMFBR austenitic structures containing as-welded residual stresses is the CEGB-R6 procedure based on a flow stress defined at 3% strain in the parent plate. When the prediction of failure loads in such structures is required, it is suggested that the CEGB-R6 procedure be used with residual/thermal stresses factored to give a maximum total stress of flow stress magnitude

  10. Tooth-bleaching procedures and their controversial effects: A literature review

    Science.gov (United States)

    Alqahtani, Mohammed Q.

    2014-01-01

    Aim This review article will help clinicians improve their understanding of the history of bleaching procedures, bleaching types, components, mechanisms, and their effects on soft tissue, tooth structures, resin composite, and bonding. Methods The controversial issues about bleaching procedures and their effects are reviewed. Additionally, the consequences of pre- and post-bleaching on the bonding potential of composite resin restorations to tooth structure are discussed. Conclusion The overall goal of the paper is to help reduce risks for patients. PMID:25408594

  11. Location of the levator veli palatini insertion following levator retropositioning, palatal pushback, and pharyngeal flap procedures.

    Science.gov (United States)

    Mulliken, J B; Giargiana, F A; Claybaugh, G J; Hoopes, J E

    1975-07-01

    A long-term cineradiographic follow-up study of twenty patients with velo-pharyngeal incompetence fails to demonstrate predictable retrodisplacement of the levator insertion following combined levator retropositioning, pushback, and pharyngeal flap procedures. Simple levator retropositioning gave posterior displacement in the two patients evaluated. Patients with normal or posterior levator insertions pre-operatively all demonstrated post-operative anterior displacement following pharyngeal flap procedures, either alone or in combination with pushback. Anterior levator displacement may be the result of scar contraction or division of the levator sling (during insetting of a pharyngeal flap). Pre-operative and post-operative speech evaluation demonstrated substantial improvement in all except 3 patients; 2 of the poor speech results were patients with demonstrated levator retrodisplacement on post-operative cineradiography.

  12. The significance of X-ray examinations of patients with Crohn's disease after intestinal-tract resections

    International Nuclear Information System (INIS)

    Kulke, H.; Hoerl, M.; Kasper, H.; Auer, I.O.

    1988-01-01

    After intestinal tract resection, the status of the intestinal tract of patients with Crohn's disease who had recurrent anastomoses versus those that did not analyzed using standardized procedures of stomach X-ray with small bowel follow through, barium enema and fistulography. The intestinal tract resections included ileostomy, transverse ileostomy, rectal ileostomy, and atypical procedures. The anstomoses and surrounding tissue were evaluated. The results were discussed and the X-ray characteristics of the current anastomosis and the existing changes in its environment were analyzed. (orig.) [de

  13. 2D-3D image registration in diagnostic and interventional X-Ray imaging

    NARCIS (Netherlands)

    Bom, I.M.J. van der

    2010-01-01

    Clinical procedures that are conventionally guided by 2D x-ray imaging, may benefit from the additional spatial information provided by 3D image data. For instance, guidance of minimally invasive procedures with CT or MRI data provides 3D spatial information and visualization of structures that are

  14. A submicron synchrotron X-ray beam generated by capillary optics

    International Nuclear Information System (INIS)

    Engstroem, P.; Larsson, S.; Rindby, A.; Buttkewitz, A.; Garbe, S.; Gaul, G.; Knoechel, A.; Lechtenberg, F.; Deutsches Elektronen-Synchrotron

    1991-01-01

    A novel capillary optics technique for focusing synchrotron X-ray beams has been applied in an experiment performed at the DORIS storage ring at HASYLAB. This new technqiue, which utilizes the total reflection properties of X-rays inside small capillaries, has recently been applied to generate microbeams of X-rays, with a beam size down to about 10 μm using conventional X-ray tubes. The result from our recent experiment shows that capillary optics can also be used to generate a submicron beam of X-rays from a synchrotron light source. A description of the capillary unit, and the alignment procedure is given. The influence of the thermal load on the device caused by the intense flux of synchrotron radiation will be discussed. Future perspectives of the capillary techniques as applied to synchrotron radiation will be discussed. (orig.)

  15. Post-operative sleep disturbance: causes, factors and effects on outcome

    DEFF Research Database (Denmark)

    Rosenberg, J; Rosenberg-Adamsen, S; Kehlet, H

    1995-01-01

    Post-operative sleep disturbance, with suppression of rapid eye movement sleep and slow wave sleep followed by a subsequent rebound, seems to be related to the magnitude of trauma and thereby to the surgical stress response. In this context, cortisol, autonomic stimulation, and certain cytokines...... may lead to abnormal sleep. Furthermore, the environment, pain and the administration of analgesics seem to be important factors in the precipitation of sleep abnormalities. Post-operative sleep disturbance may contribute to the development of episodic hypoxaemia, haemodynamic instability and altered...... mental status, all of which have an influence on post-operative morbidity and mortality. Prevention or reduction of the post-operative sleep disturbance may be achieved by minimizing surgical trauma, changing the conventional nursing procedures, avoiding opioids and treating pain with non...

  16. Soft X-ray microscopy and lithography with synchrotron radiation

    International Nuclear Information System (INIS)

    Gudat, W.

    1977-12-01

    Considerable progress in the technique microscopy with soft X-ray radiation has been achieved in particular through the application of synchrotron radiation. Various methods which are currently being studied theoretically or already being used practically will be described briefly. Attention is focussed on the method of contact microscopy. Various biological specimens have been investigated by this method with a resolution as good as 100 A. X-ray lithography which in the technical procedure is very similar to contact microscopy gives promise for the fabrication of high quality submicron structures in electronic device production. Important factors limiting the resolution and determining the performance of contact microscopy and X-ray lithography will be discussed. (orig.) [de

  17. Effect of the size of the apical enlargement with rotary instruments, single-cone filling, post space preparation with drills, fiber post removal, and root canal filling removal on apical crack initiation and propagation.

    Science.gov (United States)

    Çapar, İsmail Davut; Uysal, Banu; Ok, Evren; Arslan, Hakan

    2015-02-01

    The purpose of this study was to investigate the incidence of apical crack initiation and propagation in root dentin after several endodontic procedures. Sixty intact mandibular premolars were sectioned perpendicular to the long axis at 1 mm from the apex, and the apical surface was polished. Thirty teeth were left unprepared and served as a control, and the remaining 30 teeth were instrumented with ProTaper Universal instruments (Dentsply Maillefer, Ballaigues, Switzerland) up to size F5. The root canals were filled with the single-cone technique. Gutta-percha was removed with drills of the Rebilda post system (VOCO, Cuxhaven, Germany). Glass fiber-reinforced composite fiber posts were cemented using a dual-cure resin cement. The fiber posts were removed with a drill of the post system. Retreatment was completed after the removal of the gutta-percha. Crack initiation and propagation in the apical surfaces of the samples were examined with a stereomicroscope after each procedure. The absence/presence of cracks was recorded. Logistic regression was performed to analyze statistically the incidence of crack initiation and propagation with each procedure. The initiation of the first crack and crack propagation was associated with F2 and F4 instruments, respectively. The logistic regression analysis revealed that instrumentation and F2 instrument significantly affected apical crack initiation (P .05). Rotary nickel-titanium instrumentation had a significant effect on apical crack initiation, and post space preparation with drills had a significant impact on crack propagation. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Dual energy X-ray absorptiometry spine scans to determine abdominal fat in post-menopausal women

    Science.gov (United States)

    Bea, J. W.; Blew, R. M.; Going, S. B.; Hsu, C-H; Lee, M. C.; Lee, V. R.; Caan, B.J.; Kwan, M.L.; Lohman, T. G.

    2016-01-01

    Body composition may be a better predictor of chronic disease risk than body mass index (BMI) in older populations. Objectives We sought to validate spine fat fraction (%) from dual energy X-ray absorptiometry (DXA) spine scans as a proxy for total abdominal fat. Methods Total body DXA scan abdominal fat regions of interest (ROI) that have been previously validated by magnetic resonance imaging were assessed among healthy, postmenopausal women who also had antero-posterior spine scans (n=103). ROIs were 1) lumbar vertebrae L2-L4 and 2) L2-Iliac Crest (L2-IC), manually selected by two independent raters, and 3) trunk, auto-selected by DXA software. Intra-class correlation coefficients evaluated intra and inter-rater reliability on a random subset (N=25). Linear regression models, validated by bootstrapping, assessed the relationship between spine fat fraction (%) and total abdominal fat (%) ROIs. Results Mean age, BMI and total body fat were: 66.1 ± 4.8y, 25.8 ± 3.8kg/m2 and 40.0 ± 6.6%, respectively. There were no significant differences within or between raters. Linear regression models adjusted for several participant and scan characteristics were equivalent to using only BMI and spine fat fraction. The model predicted L2-L4 (Adj. R2: 0.83) and L2-IC (Adj.R2:0.84) abdominal fat (%) well; the adjusted R2 for trunk fat (%) was 0.78. Model validation demonstrated minimal over-fitting (Adj. R2: 0.82, 0.83, and 0.77 for L2-L4, L2-IC, and trunk fat respectively). Conclusions The strong correlation between spine fat fraction and DXA abdominal fat measures make it suitable for further development in post-menopausal chronic disease risk prediction models. PMID:27416964

  19. Model independent method to deconvolve hard X-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Polcaro, V.F.; Bazzano, A.; Ubertini, P.; La Padula, C. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale); Manchanda, R.K. (Tata Inst. of Fundamental Research, Bombay (India))

    1984-07-01

    A general purpose method to deconvolve the energy spectra detected by means of the use of a hard X-ray telescope is described. The procedure does not assume any form of input spectrum and the observed energy loss spectrum is directly deconvolved into the incident photon spectrum, the form of which can be determined independently of physical interpretation of the data. Deconvolution of the hard X-ray spectrum of Her X-1, detected during the HXR 81M experiment, by the method independent method is presented.

  20. Development of a novel micro pattern gaseous detector for cosmic ray muon tomography

    Science.gov (United States)

    Biglietti, M.; Canale, V.; Franchino, S.; Iengo, P.; Iodice, M.; Petrucci, F.

    2016-07-01

    We propose a novel detector (Thick Groove Detector, TGD) designed for cosmic ray tomography with a spatial resolution of 500 μm, trying to keep the construction procedure as simple as possible and to reduce the operating costs. The TGD belongs to the category of MPGDs with an amplification region less than 1 mm wide formed by alternate anode/cathode microstrips layers at different heights. A first 10×10 cm2 prototype has been built, divided in four sections with different test geometries. We present the construction procedure and the first results in terms of gain and stability. Preliminary studies with cosmic rays are also reported.

  1. Capillary Optics as an x-ray Condensing Lens An Alignment

    CERN Document Server

    Cappuccio, G

    2000-01-01

    The procedure of capillary lens alignment is described in detail. The theoretical basis of capillary optics is given in the framework of a comparative analysis of monocapillary and polycapillary optics. The results of x-ray $9 distribution scanning behind the capillary lens for various angle planes, together with the tting results, are presented. A qualitative explanation is given for the discrepancy between the expected and observed divergences of x-ray $9 beams transmitted by the capillary lens.

  2. Diagnostic value of radiological imaging pre- and post-drainage of pleural effusions.

    Science.gov (United States)

    Corcoran, John P; Acton, Louise; Ahmed, Asia; Hallifax, Robert J; Psallidas, Ioannis; Wrightson, John M; Rahman, Najib M; Gleeson, Fergus V

    2016-02-01

    Patients with an unexplained pleural effusion often require urgent investigation. Clinical practice varies due to uncertainty as to whether an effusion should be drained completely before diagnostic imaging. We performed a retrospective study of patients undergoing medical thoracoscopy for an unexplained effusion. In 110 patients with paired (pre- and post-drainage) chest X-rays and 32 patients with paired computed tomography scans, post-drainage imaging did not provide additional information that would have influenced the clinical decision-making process. © 2015 Asian Pacific Society of Respirology.

  3. Evaluation and treatment of failed shoulder instability procedures.

    Science.gov (United States)

    Ho, Anthony G; Gowda, Ashok L; Michael Wiater, J

    2016-09-01

    Management of the unstable shoulder after a failed stabilization procedure can be difficult and challenging. Detailed understanding of the native shoulder anatomy, including its static and dynamic restraints, is necessary for determining the patient's primary pathology. In addition, evaluation of the patient's history, physical exam, and imaging is important for identifying the cause for failure after the initial procedure. Common mistakes include under-appreciation of bony defects, failure to recognize capsular laxity, technical errors, and missed associated pathology. Many potential treatment options exist for revision surgery, including open or arthroscopic Bankart repair, bony augmentation procedures, and management of Hill Sachs defects. The aim of this narrative review is to discuss in-depth the common risk factors for post-surgical failure, components for appropriate evaluation, and the different surgical options available for revision stabilization. Level of evidence Level V.

  4. On anti-earthquake design procedure of equipment and pipings in near future

    International Nuclear Information System (INIS)

    Shibata, H.

    1981-01-01

    The requirement of anti-earthquake design of nuclear power plants is getting severe year by year. The author will try to discuss how to control its severity and how to find a proper design procedure for licensing of new plants under such severe requirements. On the other hand we suffered from the enormous volumes of documents. To decrease such volumes, the format of documents should be standardized as well as the design procedure standardization. Starting from this point, we need the research and development on the following subjects: i) Standardization of design procedure. ii) Standardization of document. iii) Establishment of standard review procedure using computer. iv) Standardization of earthquake-resistant designed equipment. v) Standardization of anti-earthquake design procedure of piping systems. vi) Introducing margin evaluation procedure to design procedure. vii) Introducing proving test procedure of active component to design procedure. viii) Establishment of evaluation of human reliability in design, fabrication, inspection procedures. ix) Establishment of the proper relation of seismic trigger level and post-earthquake design procedures. (orig./HP)

  5. A combined hands-on teaching programme and clinical pathway focused on pleural ultrasound and procedure supervision transforms pleural procedure outcomes.

    Science.gov (United States)

    Edwards, Timothy; Cook, Alistair; Salamonsen, Matthew; Bashirzadeh, Farzad; Fielding, David

    2017-11-01

    Management of pleural effusions is a common diagnostic and management problem. We reviewed the outcomes from pleural procedures after the instigation of pleural effusion management guidelines, focusing on pleural ultrasound and a hands-on teaching programme followed by procedure supervision that enabled many operators to perform such procedures. This is a retrospective analysis of all procedures performed for pleural effusions on medical patients. Outcomes were assessed prior to the instigation of pleural effusion management guidelines (pleural pathway) and hands-on teaching (January 2010 to June 2011) and following these interventions (January 2012 to June 2013). A total of 171 procedures involving 129 patients (pre-pathway group) and 146 procedures involving 115 patients (post-pathway group) was analysed. The rate of complications prior to the pleural pathway was 22.2% (38 of 171 procedures). Following the pathway, the rate of complications declined to 7.5% (11 of 146 procedures, P < 0.003). The use of pleural ultrasound increased dramatically (72.5 vs 90.2%). The number of patients who underwent repeated procedures (defined as ≥3) reduced dramatically (21 vs 7, P < 0.01). This improvement occurred using many supervised operators who completed the hands-on teaching programme (n = 32) and followed the pleural pathway (127 of 146 procedures). The instigation of a clinical pathway focused on the use of bedside pleural ultrasound, and teaching of drainage techniques with procedure supervision vastly improved patient outcomes. This not only allowed better quality of care for patients, it also provided the acquisition of new skills to medical staff, not limiting these skills to specialised staff. © 2017 Royal Australasian College of Physicians.

  6. Development of Vertical Buffered Electropolishing for Its Post-Treatment Technology on 1.5 GHz Niobium SRF Cavities

    International Nuclear Information System (INIS)

    Jin Song; Lu Xiang-Yang; Lin Lin; Zhao Kui; Wu, A. T.; Rimmer, R. A.

    2011-01-01

    We report the latest research development of vertical buffered electropolishing on its post-treatment procedure as well as the effects of several major post-treatment techniques for buffered electropolishing (BEP) processed 1.5 GHz niobium (Nb) superconducting radio frequency (SRF) cavities. With the established post-treatment procedure, an accelerating gradient of 28.4 MV/m is obtained on a single cell cavity of the cebaf shape. This is the best result in the history of BEP development. The cavity is limited by quench with a high quality factor over 1.2 × 10 10 at the quench point. Analyses from optical inspection and temperature-mapping show that the quench should be originated from the pits that were already present on the cavity before this BEP treatment. All of these factors indicate that this procedure will have a great potential to produce better results if cavities without intrinsic performance limiting imperfections are used. (nuclear physics)

  7. Manual of use and accounting of radioactive material and procedures of radiological protection for nuclear medicine

    International Nuclear Information System (INIS)

    Chavez, Miguel

    1997-03-01

    This manual of use and accounting of material radioactive and procedures of radiological safety tries to facilitate workings of protection of material radioactive in services of medicine nuclear, during diagnosis (examinations with x-rays, or those that are made in nuclear medicine), or during the processing of diseases, mainly of the carcinomas (x-ray)

  8. Post-SM4 Sensitivity Calibration of the STIS Echelle Modes

    Science.gov (United States)

    Bostroem, K. Azalee; Aloisi, A.; Bohlin, R.; Hodge, P.; Proffitt, C.

    2012-01-01

    On-orbit sensitivity curves for all echelle modes were derived for post - servicing mis- sion 4 data using observations of the DA white dwarf G191-B2B. Additionally, new echelle ripple tables and grating dependent bad pixel tables were created for the FUV and NUV MAMA. We review the procedures used to derive the adopted throughputs and implement them in the pipeline as well as the motivation for the modification of the additional reference files and pipeline procedures.

  9. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  10. Focusing polycapillary to reduce parasitic scattering for inelastic x-ray measurements at high pressure

    International Nuclear Information System (INIS)

    Chow, P.; Xiao, Y. M.; Rod, E.; Bai, L. G.; Shen, G. Y.; Sinogeikin, S.; Gao, N.; Ding, Y.; Mao, H.-K.

    2015-01-01

    The double-differential scattering cross-section for the inelastic scattering of x-ray photons from electrons is typically orders of magnitude smaller than that of elastic scattering. With samples 10-100 μm size in a diamond anvil cell at high pressure, the inelastic x-ray scattering signals from samples are obscured by scattering from the cell gasket and diamonds. One major experimental challenge is to measure a clean inelastic signal from the sample in a diamond anvil cell. Among the many strategies for doing this, we have used a focusing polycapillary as a post-sample optic, which allows essentially only scattered photons within its input field of view to be refocused and transmitted to the backscattering energy analyzer of the spectrometer. We describe the modified inelastic x-ray spectrometer and its alignment. With a focused incident beam which matches the sample size and the field of view of polycapillary, at relatively large scattering angles, the polycapillary effectively reduces parasitic scattering from the diamond anvil cell gasket and diamonds. Raw data collected from the helium exciton measured by x-ray inelastic scattering at high pressure using the polycapillary method are compared with those using conventional post-sample slit collimation

  11. Significance of X-ray examinations of patients with Crohn's disease after intestinal-tract resections

    Energy Technology Data Exchange (ETDEWEB)

    Kulke, H.; Hoerl, M.; Kasper, H.; Auer, I.O.

    1988-12-01

    After intestinal tract resection, the status of the intestinal tract of patients with Crohn's disease who had recurrent anastomoses versus those that did not analyzed using standardized procedures of stomach X-ray with small bowel follow through, barium enema and fistulography. The intestinal tract resections included ileostomy, transverse ileostomy, rectal ileostomy, and atypical procedures. The anstomoses and surrounding tissue were evaluated. The results were discussed and the X-ray characteristics of the current anastomosis and the existing changes in its environment were analyzed.

  12. Cement technique for reducing post-operative bursitis after trochanteric fixation.

    Science.gov (United States)

    Derman, Peter B; Horneff, John G; Kamath, Atul F; Garino, Jonathan

    2013-02-01

    Post-operative trochanteric bursitis is a known complication secondary to the surgical approach in total hip arthroplasty. This phenomenon may be partially attributable to repetitive microtrauma generated when soft tissues rub against implanted hardware. Significant rates of post-operative trochanteric bursitis have been observed following procedures in which a trochanteric fixation device, such as a bolt-washer mechanism or a cable-grip/claw system, is used to secure the trochanteric fragment after trochanteric osteotomy. We present a simple technique for use with a bolt-washer system or grip plate in which trochanteric components are covered in bone wax followed by a layer of cement to decrease friction and to diminish the risk of post-operative bursitis.

  13. Post-processing of digital images.

    Science.gov (United States)

    Perrone, Luca; Politi, Marco; Foschi, Raffaella; Masini, Valentina; Reale, Francesca; Costantini, Alessandro Maria; Marano, Pasquale

    2003-01-01

    Post-processing of bi- and three-dimensional images plays a major role for clinicians and surgeons in both diagnosis and therapy. The new spiral (single and multislice) CT and MRI machines have allowed better quality of images. With the associated development of hardware and software, post-processing has become indispensable in many radiologic applications in order to address precise clinical questions. In particular, in CT the acquisition technique is fundamental and should be targeted and optimized to obtain good image reconstruction. Multiplanar reconstructions ensure simple, immediate display of sections along different planes. Three-dimensional reconstructions include numerous procedures: multiplanar techniques as maximum intensity projections (MIP); surface rendering techniques as the Shaded Surface Display (SSD); volume techniques as the Volume Rendering Technique; techniques of virtual endoscopy. In surgery computer-aided techniques as the neuronavigator, which with information provided by neuroimaging helps the neurosurgeon in simulating and performing the operation, are extremely interesting.

  14. Radiation exposure of the UK population from medical and dental x-ray examinations

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.F.

    2002-03-01

    Knowledge of recent trends in the radiation doses from x-ray examinations and their distribution for the UK population provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimise the protection of the population in a cost-effective manner. In this report, the results of a recent survey of the frequency of medical and dental x-ray examinations in the UK and contemporary data on the radiation doses typically received by patients, are used to assess trends in the extent and the pattern of the population exposure. Individual patient doses, expressed in terms of the effective dose, range from a few microsieverts for simple radiographic examinations of the teeth, limbs or chest to tens of millisieverts for prolonged fluoroscopic procedures or some computed tomography (CT) examinations. A total of about 41.5 million medical and dental x-ray examinations are now conducted each year in the UK (0.70 examination per head of population) resulting in an annual per caput effective dose of 330 μSv. This is not significantly different from the previous rough estimate of 350 μSv for 1991. However, over the last ten years CT has more than doubled its contribution and is now responsible for 40% of the total dose to the population from medical x-rays. In contrast, the contribution from conventional radiographic and fluoroscopic examinations has nearly halved to about 44%. Interventional and angiographic procedures together contribute the remaining 16%. The annual per caput dose of 330 μSv is low in comparison with other countries having similarly developed systems of health care. This is due to both a lower frequency of x-ray examinations per head of population and generally lower doses in the UK than in other developed countries. However, the much increased contributions of CT, angiography and interventional procedures to the UK population dose indicate an urgent need to develop radiation protection and optimisation activities for

  15. Non-destructive testing of rocket propellant quality using -X-ray radiography

    International Nuclear Information System (INIS)

    Arayaprecha, W.

    1979-01-01

    Currently, X-rays radiography has been used extensively in various industries. In this thesis, X-rays has been used in the study of compaction of rocket propellant. For a rocket, to gain an accurate guidance result, the propellant used must be mixed and compacted thoroughly. The quality control of the production of propellant sticks must be carefully done. In this study of non-destructive quality testing of rocket propellant, at first the ultrasonic rays was used to test its homogeneity. However, because the density of the propellant was too low, the test equipment could not detect any reflected signals from the propellant being tested. Then the new procedure using X-rays radiography was tried. The variables in the test procedure were voltage, amperage and the focal-film distance. Also different types of films were used. The results of this experiment were then used to construct an exposure chart for testing the homogeneity of the rocket propellant. The advantage of this chart is that a tester can use this table with propellant sticks of different sizes if they have similar density to the density specified in the chart. Also, it is not necessary that the mixture of the testing propellant be the same as the ones used to construct this chart

  16. Charged particle induced energy dispersive X-ray analysis

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1979-01-01

    This review article deals with the X-ray emission induced by heavy, charged particles and the use of this process as an analytical method (PIXE). The physical processes involved, X-ray emission and the various reactions contributing to the background, are described in some detail. The sensitivity is calculated theoretically and the results compared with practical experience. A discussion is given on how the sensitivity can be optimized. The experimental arrangements are described and the various technical problems discussed. The analytical procedure, especially the sample preparation, is described in considerable detail. A number of typical practical applications are discussed. (author)

  17. Patients' satisfaction with the Nuss procedure

    International Nuclear Information System (INIS)

    Ishimaru, Tetsuya; Iwanaka, Tadashi; Uchida, Hiroo; Kawashima, Hiroshi; Gotoh, Chikashi; Satoh, Kaori; Yoshida, Mariko; Kitano, Yoshihiro

    2009-01-01

    The purpose of this study is to investigate the satisfaction of patients who have already finished bar removal. Fifty-four patients with pectus excavatum underwent the Nuss procedure between July 2000 and December 2007 and the bar was removed in 41 of them at our hospital. A telephone questionnaire was administered to their parents or the patients (12 years old or older). The questions were as follows: self-assessment of the present thoracic form on a 5-point scale, whether it was good to have undergone the Nuss procedure (Y/N), whether the patient will recommend this procedure to another patient (Y/N). Thirty-nine patients responded to the questionnaire. Median age at the bar insertion was 83 months (range: 63-189 months). The bar was removed about 2 years after the initial operation. The median period after removal was 29 months ( range: 2-65 months). The mean point for the thoracic form was 4.2 (5 points: 20, 4 points: 11, 3 points: 5, 2 points: 3). Thirty-eight patients answered that they were satisfied with this procedure. Thirty-four patients answered that they would recommend this procedure to another patient. Eight patients reported that redepression occurred after bar removal. Six of them are under observation because their thoracic deformity is mild. Patients' satisfaction with the Nuss procedure was high. However, our study shows the possibility of post-removal recurrence. There seems to be a tendency for patients to assess their thoracic form more strictly than the doctors. (author)

  18. Hypermobility of the first metatarsal bone in patients with Rheumatoid arthritis treated by lapidus procedure

    Directory of Open Access Journals (Sweden)

    Popelka Stanislav

    2012-08-01

    Full Text Available Abstract Background Foot deformities and related problems of the forefoot are very common in patients with rheumatoid arthritis. The laxity of the medial cuneometatarsal joint and its synovitis are important factors in the development of forefoot deformity. The impaired joint causes the first metatarsal bone to become unstable in the frontal and sagittal planes. In this retrospective study we evaluated data of patients with rheumatoid arthritis who underwent Lapidus procedure. We evaluated the role of the instability in a group of patients, focusing mainly on the clinical symptoms and X-ray signs of the instability. Methods The study group included 125 patients with rheumatoid arthritis. The indications of the Lapidus procedure were a hallux valgus deformity greater than 15 degrees and varus deformity of the first metatarsal bone with the intermetatarsal angle greater than 15 degrees on anterio-posterior weight-bearing X-ray. Results Data of 143 Lapidus procedures of 125 patients with rheumatoid arthritis, who underwent surgery between 2004 and 2010 was evaluated. Signs and symptoms of the first metatarsal bone instability was found in 92 feet (64.3% in our group. The AOFAS score was 48.6 before and 87.6 six months after the foot reconstruction. Nonunion of the medial cuneometatarsal joint arthrodesis on X-rays occurred in seven feet (4.9%. Conclusion The Lapidus procedure provides the possibility to correct the first metatarsal bone varus position and its instability, as well as providing the possibility to achieve a painless foot for walking. We recommend using the procedure as a preventive surgery in poorly symptomatic patients with rheumatoid arthritis in case of the first metatarsal bone hypermobility.

  19. Larval x-ray irradiation influences protein expression in pupae of the Oriental fruit fly, Bactrocera Dorsalis

    Science.gov (United States)

    Third instar larvae were exposed to X-ray treatment of the Oriental fruit fly, Bactrocera dorsalis. Irradiated pupae were collected daily. Biological performance parameters of pupae and adults of larvae treated with X-ray irradiation were evaluated. Standard proteomics procedures such as densitometr...

  20. Intra-operative removal of chest tube in video-assisted thoracoscopic procedures

    Directory of Open Access Journals (Sweden)

    Moustafa M. El-Badry

    2017-12-01

    Conclusions: Intra-operative removal of chest tube during VATS procedures was a safe technique in well selected patients with an intra-operative successful air-leak test with radiological and clinical follow-up. This technique provided lesser post-operative pain with shorter hospital stay.

  1. Evaluation of Patient Radiation Dose during Cardiac Interventional Procedures: What Is the Most Effective Method?

    International Nuclear Information System (INIS)

    Chida, K.; Saito, H.; Ishibashi, T.; Zuguchi, M.; Kagaya, Y.; Takahashi, S.

    2009-01-01

    Cardiac interventional radiology has lower risks than surgical procedures. This is despite the fact that radiation doses from cardiac intervention procedures are the highest of any commonly performed general X-ray examination. Maximum radiation skin doses (MSDs) should be determined to avoid radiation-associated skin injuries in patients undergoing cardiac intervention procedures. However, real-time evaluation of MSD is unavailable for many cardiac intervention procedures. This review describes methods of determining MSD during cardiac intervention procedures. Currently, in most cardiac intervention procedures, real-time measuring of MSD is not feasible. Thus, we recommend that physicians record the patient's total entrance skin dose, such as the dose at the interventional reference point when it can be monitored, in order to estimate MSD in intervention procedures

  2. X-ray changes of children with chronic renal insufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Ponhold, W.; Balzar, E. (Vienna Univ. (Austria). Kinderklinik)

    1983-01-01

    The typical changes of renal osteopathy are shown in the X-rays of 7 children with end-stage renal disease treated with chronic intermittent hemodialysis. The exact evaluation of the granular structural changes of the cranium, the evidence of osteomalacia because of the hazy appearance of the vertebrae and the broadening of the sacroilical joints depend highly on subjective judgement and the technical X-ray procedures used. Unmistakable radiological diagnoses can be made when a broadening of the metalphyseal zones, epiphysioloysis as well as characteristic changes in the finder phalanges (acroosteolyses, spiculae, tunnelation) are present.

  3. Aromatherapy for reducing colonoscopy related procedural anxiety and physiological parameters: a randomized controlled study.

    Science.gov (United States)

    Hu, Pei-Hsin; Peng, Yen-Chun; Lin, Yu-Ting; Chang, Chi-Sen; Ou, Ming-Chiu

    2010-01-01

    Colonoscopy is generally tolerated, some patients regarding the procedure as unpleasant and painful and generally performed with the patient sedated and receiving analgesics. The effect of sedation and analgesia for colonoscopy is limited. Aromatherapy is also applied to gastrointestinal endoscopy to reduce procedural anxiety. There is lack of information about aromatherapy specific for colonoscopy. In this study, we aimed to performed a randomized controlled study to investigate the effect of aromatherapy on relieve anxiety, stress and physiological parameters of colonoscopy. A randomized controlled trail was carried out and collected in 2009 and 2010. The participants were randomized in two groups. Aromatherapy was then carried out by inhalation of Sunflower oil (control group) and Neroli oil (Experimental group). The anxiety index was evaluated by State Trait Anxiety Inventory-state (STAI-S) score before aromatherapy and after colonoscopy as well as the pain index for post-procedural by visual analogue scale (VAS). Physiological indicators, such as blood pressure (systolic and diastolic blood pressure), heart rate and respiratory rate were evaluated before and after aromatherapy. Participates in this study were 27 subjects, 13 in control group and 14 in Neroli group with average age 52.26 +/- 17.79 years. There was no significance of procedural anxiety by STAI-S score and procedural pain by VAS. The physiological parameters showed a significant lower pre- and post-procedural systolic blood pressure in Neroli group than control group. Aromatic care for colonoscopy, although with no significant effect on procedural anxiety, is an inexpensive, effective and safe pre-procedural technique that could decrease systolic blood pressure.

  4. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    International Nuclear Information System (INIS)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J.; Dziadowicz, M.; Kopeć, E.; Majewska, U.; Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I.; Wudarczyk-Moćko, J.; Góźdź, S.

    2015-01-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  5. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Dziadowicz, M.; Kopeć, E. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Majewska, U. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Wudarczyk-Moćko, J. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Góźdź, S. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Institute of Public Health, Jan Kochanowski University, IX Wieków Kielc 19, 25-317 Kielce (Poland)

    2015-12-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  6. Implementation of Ray Safe i2 System for staff dose measuring in interventional radiology

    International Nuclear Information System (INIS)

    Gershan, Vesna; Atsovska, Violeta

    2013-01-01

    Interventional radiology procedures usually delivered the highest radiation dose to the patients as well as to medical personal. Beside another factors like patient size, fluoroscopy time, machine calibration etc., a good clinical practice has strong effects to staff and patient’s radiation dose. Materials and methods: In August 2012, a Ray Safe i2 system was installed in a private hospital in Skopje. The main purpose of this dosimetry system is to provide real time indication for the current exposure level of the medical personal. Knowing that, the staff has prerequisites to adjust their behavior to minimize unnecessary exposure like changing distance from exposed volume, C-ram angulations, field of view etc. and on this way to develop a good clinical practice. The Ray Safe i2 system is consisted by ten digital dosimeters, two dock stations, real time display, dose viewer and dose manager software. During interventional procedures, each involved staff wears dosimeter which measures and records X-Ray exposure every second and transfer the data wirelessly to the real time display. Color indication bars (green, yellow, red) represents the intensity of the currently received exposure, whereas green zone indicates < 0.2 mSv/h, yellow zone from 0.2 to 2 mSv/h and red zone indications from 2 to 20 mSv/h. Additionally, accumulated dose per individual is displayed next to the color indication bars. By using the software, information about personal dose history, such as annual dose, dose per particular session, hour, day or week, can be viewed and analyzed. Results: In this work it was found that staff accumulated doses were constantly increased over time, but reported number of procedures does not correspond to this tendency. Our assumption is that there is a misleading between reported number and actual performed procedures. Doctor1 received 55 times more dose than Doctor2 and Nurse1 received 11 to 3 times more dose than another Nurses. It was found a correlation of R2

  7. Valorization procedure of x-ray equipment in the mammography equipment

    International Nuclear Information System (INIS)

    Ruiz, M. A.; Ordonez, J.; Antolin, E.; Andres, J. C. de; Gonzalez, I.; Arranz, L.; Sastre, J. M.; Ferrer, N.

    2006-01-01

    The Ramon y Cajal Hospital mammography service has three X-rays units, two of them with high resolution computed radiography (CR) system and one with flat-panel (FP)-based full-field digital mammography system. Periodic control dose tests in patients have shown lower glandular dose levels (DGM) than references provided by European Protocol for de Quality Control of de Physical and Technical Aspects of Mammography Screening. In this work, we have tried to establish an easy method for DGM calculation which is representative of the three equipment results. For this aim, we have defined an index which is measured along the time like a reference point. This index is defined as the relation between the blind test punctuations of a standard phantom image given by at least three radiologists in the Unit, and the average DGM values obtained in 20 patients in each Unit (using random thickness and random mama composition). (Author)

  8. APE (state-oriented approach) centralized control procedures

    International Nuclear Information System (INIS)

    Astier, D.; Depont, G.; Van Dermarliere, Y.

    2004-01-01

    This article presents the progressive implementation of the state-oriented approach (APE) for centralized control procedures in French nuclear power plants. The implementation began in the years 1982-83 and it concerned only the circuits involved in engineered safeguard systems such IS (safety injection), EAS (containment spray system) and GMPP (reactor coolant pump set). In 2003 the last PWR unit switched from the event oriented approach to APE for post-accidental situations

  9. Bi-directional x-ray phase-contrast mammography.

    Directory of Open Access Journals (Sweden)

    Kai Scherer

    Full Text Available Phase-contrast x-ray imaging is a promising improvement of conventional absorption-based mammography for early tumor detection. This potential has been demonstrated recently, utilizing structured gratings to obtain differential phase and dark-field scattering images. However, the inherently anisotropic imaging sensitivity of the proposed mono-directional approach yields only insufficient diagnostic information, and has low diagnostic sensitivity to highly oriented structures. To overcome these limitations, we present a two-directional x-ray phase-contrast mammography approach and demonstrate its advantages by applying it to a freshly dissected, cancerous mastectomy breast specimen. We illustrate that the two-directional scanning procedure overcomes the insufficient diagnostic value of a single scan, and reliably detects tumor structures, independently from their orientation within the breast. Our results indicate the indispensable diagnostic necessity and benefit of a multi-directional approach for x-ray phase-contrast mammography.

  10. X-ray diffractometry with spatial resolution

    International Nuclear Information System (INIS)

    Zeiner, K.

    1981-04-01

    X-ray diffractometry is one of the extensively used methods for investigation of the crystalline structure of materials. Line shape and position of a diffracted line are influenced by grain size, deformation and stress. Spatial resolution of one of these specimen characteristics is usually achieved by point-focused X-ray beams and subsequently analyzing different specimen positions. This work uses the method of image reconstruction from projections for the generation of distribution maps. Additional experimental requirements when using a conventional X-ray goniometer are a specimen scanning unit and a computer. The scanning unit repeatedly performs a number of translation steps followed by a rotation step in a fixed X-ray tube/detector (position sensitive detector) arrangement. At each specimen position a diffraction line is recorded using a line-shaped X-ray beam. This network of diffraction lines (showing line resolution) is mathematically converted to a distribution map of diffraction lines and going thus a point resolution. Specimen areas of up to several cm 2 may be analyzed with a linear resolution of 0.1 to 1 mm. Image reconstruction from projections must be modified for generation of ''function-maps''. This theory is discussed and demonstrated by computer simulations. Diffraction line analysis is done for specimen deformation using a deconvolution procedure. The theoretical considerations are experimentally verified. (author)

  11. Practical borehole logging procedures for mineral exploration, with emphasis on uranium

    International Nuclear Information System (INIS)

    1986-01-01

    Borehole logging is a basic tool in the exploration for and delineation of uranium deposits. This manual describes recommended procedures for carrying out borehole logging, concentrating on practical aspects of the operation of interest to those actually involved in day-to-day field work. The book begins with a discussion of boreholes and then deals with gamma ray logging as the main method of interest. Information is also provided on other techniques including resistance, spontaneous potential, density and neutron logging. Field procedures are described, and examples of logs and interpretations are given. The appendices provide information on calibration procedures and correction factors, a glossary of useful terms and some relevant basic data regarding drill holes and drilling

  12. 3D X-Ray Nanotomography of Cells Grown on Electrospun Scaffolds.

    Science.gov (United States)

    Bradley, Robert S; Robinson, Ian K; Yusuf, Mohammed

    2017-02-01

    Here, it is demonstrated that X-ray nanotomography with Zernike phase contrast can be used for 3D imaging of cells grown on electrospun polymer scaffolds. The scaffold fibers and cells are simultaneously imaged, enabling the influence of scaffold architecture on cell location and morphology to be studied. The high resolution enables subcellular details to be revealed. The X-ray imaging conditions were optimized to reduce scan times, making it feasible to scan multiple regions of interest in relatively large samples. An image processing procedure is presented which enables scaffold characteristics and cell location to be quantified. The procedure is demonstrated by comparing the ingrowth of cells after culture for 3 and 6 days. © 2016 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Investigation of atomic correlations in amorphous substances in the event of x-ray diffraction

    International Nuclear Information System (INIS)

    Birkelund, K.; Dahl Jensen, K.

    1990-06-01

    The aim was to determine a procedure for the experimental investigation of atomic correlations in monatomic amorphous substances (exemplified in amorphic germanium) that occur in relation to X-ray diffractometry, based on the classic theory of spreading. The underlying theory and a description of the experimental procedures are presented. (AB)

  14. A randomized trial of rectal indomethacin to prevent post-ERCP pancreatitis.

    Science.gov (United States)

    Elmunzer, B Joseph; Scheiman, James M; Lehman, Glen A; Chak, Amitabh; Mosler, Patrick; Higgins, Peter D R; Hayward, Rodney A; Romagnuolo, Joseph; Elta, Grace H; Sherman, Stuart; Waljee, Akbar K; Repaka, Aparna; Atkinson, Matthew R; Cote, Gregory A; Kwon, Richard S; McHenry, Lee; Piraka, Cyrus R; Wamsteker, Erik J; Watkins, James L; Korsnes, Sheryl J; Schmidt, Suzette E; Turner, Sarah M; Nicholson, Sylvia; Fogel, Evan L

    2012-04-12

    Preliminary research suggests that rectally administered nonsteroidal antiinflammatory drugs may reduce the incidence of pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP). In this multicenter, randomized, placebo-controlled, double-blind clinical trial, we assigned patients at elevated risk for post-ERCP pancreatitis to receive a single dose of rectal indomethacin or placebo immediately after ERCP. Patients were determined to be at high risk on the basis of validated patient- and procedure-related risk factors. The primary outcome was post-ERCP pancreatitis, which was defined as new upper abdominal pain, an elevation in pancreatic enzymes to at least three times the upper limit of the normal range 24 hours after the procedure, and hospitalization for at least 2 nights. A total of 602 patients were enrolled and completed follow-up. The majority of patients (82%) had a clinical suspicion of sphincter of Oddi dysfunction. Post-ERCP pancreatitis developed in 27 of 295 patients (9.2%) in the indomethacin group and in 52 of 307 patients (16.9%) in the placebo group (P=0.005). Moderate-to-severe pancreatitis developed in 13 patients (4.4%) in the indomethacin group and in 27 patients (8.8%) in the placebo group (P=0.03). Among patients at high risk for post-ERCP pancreatitis, rectal indomethacin significantly reduced the incidence of the condition. (Funded by the National Institutes of Health; ClinicalTrials.gov number, NCT00820612.).

  15. Outcome of the TURP-TUVP sandwich procedure for minimally ...

    African Journals Online (AJOL)

    shanker

    TURP–TUVP sandwich procedure for the surgical treatment of BPH larger than 40cc in volume. 23 used was 21.5 L (SD = 4.9).The mean post-operative hospital stay was 3.5 days (range 3- 4 days). Overall,. 11 (19%) patients had blood transfusion, there was no incidence of TUR syndrome and one mortality was recorded ...

  16. Endodontic flare-ups: comparison of incidence between single and multiple visits procedures in patients attending a Nigerian teaching hospital.

    Science.gov (United States)

    Oginni, Ao; Udoye, C I

    2004-12-01

    The present study was performed to compare the incidence of endodontic flare ups in single with multiple visits treatment procedures, to establish the relationship between pre-operative and post obturation pain in patients attending for endodontic therapy in a Nigerian teaching Hospital. Patients were randomly assigned to either single visit or multiple visits group. Data collected at root canal treatment appointment and recall visits (1st, 7th and 30th day post obturation) include pulp vitality status, the presence or absence of pre-operative pain, presence and degree of post obturation pain. Presence of endodontic flare-ups (defined as either patient's report of pain not controlled with over the counter medication and or increasing swelling). The compiled data were analyzed using chi-square where applicable. P level endodontic flare-ups (8.1 %) were recorded in the multiple visits group compared to 19 (18,3%) flare-ups for the single visit group, P = 0.02. For both single and multiple visits procedures, there were statistically significant correlations between pre operative and post obturation pain (P = 0.002 and P = 0.0004 respectively). Teeth with vital pulps reported the lowest frequency of post obturation pain (48.8%), while those with non vital pulps were found to have the highest frequency oh post obturation pain (50,3%), P = 0.9. Although the present study reported higher incidences for post obturation pain and flare-ups following the single visit procedures, single visit endodontic therapy has been shown to be a safe and effective alternative to multiple visits treatment.

  17. Post irradiation test report of irradiated DUPIC simulated fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Jung, I. H.; Moon, J. S. and others

    2001-12-01

    The post-irradiation examination of irradiated DUPIC (Direct Use of Spent PWR Fuel in CANDU Reactors) simulated fuel in HANARO was performed at IMEF (Irradiated Material Examination Facility) in KAERI during 6 months from October 1999 to March 2000. The objectives of this post-irradiation test are i) the integrity of the capsule to be used for DUPIC fuel, ii) ensuring the irradiation requirements of DUPIC fuel at HANARO, iii) performance verification in-core behavior at HANARO of DUPIC simulated fuel, iv) establishing and improvement the data base for DUPIC fuel performance verification codes, and v) establishing the irradiation procedure in HANARO for DUPIC fuel. The post-irradiation examination performed are γ-scanning, profilometry, density, hardness, observation the microstructure and fission product distribution by optical microscope and electron probe microanalyser (EPMA)

  18. Microstructural Quantification, Property Prediction, and Stochastic Reconstruction of Heterogeneous Materials Using Limited X-Ray Tomography Data

    Science.gov (United States)

    Li, Hechao

    An accurate knowledge of the complex microstructure of a heterogeneous material is crucial for quantitative structure-property relations establishment and its performance prediction and optimization. X-ray tomography has provided a non-destructive means for microstructure characterization in both 3D and 4D (i.e., structural evolution over time). Traditional reconstruction algorithms like filtered-back-projection (FBP) method or algebraic reconstruction techniques (ART) require huge number of tomographic projections and segmentation process before conducting microstructural quantification. This can be quite time consuming and computationally intensive. In this thesis, a novel procedure is first presented that allows one to directly extract key structural information in forms of spatial correlation functions from limited x-ray tomography data. The key component of the procedure is the computation of a "probability map", which provides the probability of an arbitrary point in the material system belonging to specific phase. The correlation functions of interest are then readily computed from the probability map. Using effective medium theory, accurate predictions of physical properties (e.g., elastic moduli) can be obtained. Secondly, a stochastic optimization procedure that enables one to accurately reconstruct material microstructure from a small number of x-ray tomographic projections (e.g., 20 - 40) is presented. Moreover, a stochastic procedure for multi-modal data fusion is proposed, where both X-ray projections and correlation functions computed from limited 2D optical images are fused to accurately reconstruct complex heterogeneous materials in 3D. This multi-modal reconstruction algorithm is proved to be able to integrate the complementary data to perform an excellent optimization procedure, which indicates its high efficiency in using limited structural information. Finally, the accuracy of the stochastic reconstruction procedure using limited X-ray

  19. Pre-operative assessment and post-operative care in elective shoulder surgery.

    Science.gov (United States)

    Akhtar, Ahsan; Macfarlane, Robert J; Waseem, Mohammad

    2013-01-01

    Pre-operative assessment is required prior to the majority of elective surgical procedures, primarily to ensure that the patient is fit to undergo surgery, whilst identifying issues that may need to be dealt with by the surgical or anaesthetic teams. The post-operative management of elective surgical patients begins during the peri-operative period and involves several health professionals. Appropriate monitoring and repeated clinical assessments are required in order for the signs of surgical complications to be recognised swiftly and adequately. This article examines the literature regarding pre-operative assessment in elective orthopaedic surgery and shoulder surgery, whilst also reviewing the essentials of peri- and post-operative care. The need to recognise common post-operative complications early and promptly is also evaluated, along with discussing thromboprophylaxis and post-operative analgesia following shoulder surgery.

  20. Dual-energy X-ray absorptiometry predicts bone formation in lower limb callotasis lengthening.

    OpenAIRE

    Maffulli, N.; Cheng, J. C.; Sher, A.; Lam, T. P.

    1997-01-01

    The rate of regenerate bone mineral content (BMC) acceleration was studied using dual-energy X-ray absorptiometry (DEXA) in callotasis lengthening of the lower limb. Eleven youngsters (age range 5-17 years) undergoing callotasis lengthening for congenital, post-traumatic or post-infective conditions were studied longitudinally. Patients were initially scanned once a week until completion of the lengthening phase, and at 2-week intervals thereafter until removal of the fixator. They were subse...

  1. Evaluating change in attitude towards mathematics using the 'then-now' procedure in a cooperative learning programme.

    Science.gov (United States)

    Townsend, Michael; Wilton, Keri

    2003-12-01

    Tertiary students' attitudes to mathematics are frequently negative and resistant to change, reflecting low self-efficacy. Some educators believe that greater use should be made of small group, collaborative teaching. However, the results of such interventions should be subject to assessments of bias caused by a shift in the frame of reference used by students in reporting their attitudes. This study was designed to assess whether traditional pretest-post-test procedures would indicate positive changes in mathematics attitude during a programme of cooperative learning, and whether an examination of any attitudinal change using the 'then-now' procedure would indicate bias in the results due to a shift in the internal standards for expressing attitude. Participants were 141 undergraduate students enrolled in a 12-week statistics and research design component of a course in educational psychology. Using multivariate procedures, pretest, post-test, and then-test measures of mathematics self-concept and anxiety were examined in conjunction with a cooperative learning approach to teaching. Significant positive changes between pretest and post-test were found for both mathematics self-concept and mathematics anxiety. There were no significant differences between the actual pretest and retrospective pretest measures of attitude. The results were not moderated by prior level of mathematics study. Conclusions about the apparent effectiveness of a cooperative learning programme were strengthened by the use of the retrospective pretest procedure.

  2. Post-irradiation stability of polyvinyl chloride at sterilizing doses

    International Nuclear Information System (INIS)

    Naimian, F.; Katbab, A.A.; Nazokdast, H.

    1994-01-01

    Post-irradiation stability of plasticized PVC irradiated by 60 Co gamma ray at sterilizing doses has been studied. Effects of irradiation upon chemical structure, mechanical properties and rheological behaviour of samples contained different amounts of Di(2-ethylhexyl)phthalate as plasticizer have been investigated. Formation of conjugated double bonds, carbonyl and hydroxyl groups have been followed by UV and FTIR spectrometers up to 6 months after irradiation. FTIR spectra of irradiated samples showed no significant changes in carbonyl and hydroxyl groups even 6 months after irradiation. However, changes in UV-visible spectra was observed for the irradiated samples up to 6 months post-irradiation. This has been attributed to the formation of polyenes which leads to the discoloration of this polymer. Despite a certain degree of discoloration, it appears that the mechanical properties of PVC are not affected by irradiation at sterilizing doses. No change in the melt viscosity of the irradiated PVC samples with post-irradiation was observed, which is inconsistent with the IR results. (author)

  3. Treatment of nitridation by microwave post discharge plasma in an AISI 4140 steel; Tratamiento de nitruracion por plasma post-descarga micro-ondas en un acero AISI 4140

    Energy Technology Data Exchange (ETDEWEB)

    Medina F, A. [Instituto Tecnologico de Morelia, Morelia e Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Rodriguez L, V.; Zamora R, L. [ININ, Mexico D.F. (Mexico); Oseguera P, J

    1998-07-01

    The objective of this work is to determine through X-ray diffraction, microhardness measurement and scanning electron microscopy those main operation parameters of the microwave post discharge treatment (temperature of treatment, gas mixture and permanence time) nitriding an AISI 4140 steel and to characterize the compact layer of nitrides formed during the treatment. (Author)

  4. Evaluation of post-operative prophylactic irradiation for carcinoma of the esophagus

    International Nuclear Information System (INIS)

    Mafune, Ken-ichi; Tanaka, Yoichi; Fujita, Kichishiro; Sakura, Mizuyoshi

    1987-01-01

    Of 147 patients with carcinoma of the esophagus resected at Saitama Cancer Center Hospital for 10 years, 98 cases were studied to evaluate post-operative prophylactic irradiation. The total dose of irradiation was up to 4,000 ∼ 5,000 rads of Linac X-ray and the irradiated field was T-shaped covering the upper mediastinal and bilateral cervical regions. The prognosis of the post-operative irradiated group (56 cases) was significantly better than that of the control group (42 cases) (p < 0.01). This study resulted in a five-year survival rate of 34.2 percent for patients in the post-operative irradiated group, compared to 16.7 percent for those in the control group. Further detailed comparative studies revealed similar results. Cancer recurrence occurred at the irradiated fields in 8 cases (14.3 %), though in 15 cases (35.7 %) of the control group. This suggested the local suppressive effect of the post-operative irradiation to the cancer recurrence. (author)

  5. Multiple imaging procedures including MRI for the bladder cancer

    International Nuclear Information System (INIS)

    Mikata, Noriharu; Suzuki, Makoto; Takeuchi, Takumi; Kunisawa, Yositaka; Fukutani, Keiko; Kawabe, Kazuki

    1986-01-01

    Endoscopic photography, double contrast cystography, transurethral echography, X-ray CT scan, and MRI (magnetic resonance imaging) were utilized for the staging diagnosis of the four patients with carcinoma of the bladder. In the first case, a 70-year-old man, since all of the five imaging procedures suggested a superficial and pedunculated tumor, his bladder cancer was considered T1. The classification of stage T3 carcinoma was made for the second 86-year-old male. Because all of his imaging examinations showed a tumor infiltrating deep muscle and penetrating the bladder wall. The third case was a 36-year-old male. His clinical stage was diagnosed as T2 or T3a by cystophotography, double contrast cystogram, ultrasonography, and X-ray CT scan. However, MRI showed only thickened bladder wall and the infiltrating tumor could not be distinguished from the hypertrophic wall. The last patient, a 85-year-old female, had a smaller Ta cancer. Her double contrast cystography revealed the small tumor at the lateral bladder wall. But, the tumor could not be detected by transaxial, sagittal and coronal scans. Multiple imaging procedures combining MRI and staging diagnosis of the bladder carcinoma were discussed. (author)

  6. Implementation of an electromagnetic imaging system to facilitate nasogastric and post-pyloric feeding tube placement in patients with and without critical illness.

    Science.gov (United States)

    Windle, E M; Beddow, D; Hall, E; Wright, J; Sundar, N

    2010-02-01

    Artificial nutrition support is required to optimise nutritional status in many patients. Traditional methods of placing feeding tubes may incur clinical risk and financial costs. A technique facilitating placement of nasogastric and post-pyloric tubes via electromagnetic visual guidance may reduce the need for X-ray exposure, endoscopy time and the use of parenteral nutrition. The present study aimed to audit use of such a system at initial implementation in patients within an acute NHS Trust. A retrospective review was undertaken of dietetic and medical records for the first 14 months of using the Cortrak system. Data were collected on referral origin, preparation of the patient prior to insertion, placement success rates and need for X-ray. Cost analysis was also performed. Referrals were received from primary consultants or consultant intensivists, often on the advice of the dietitian. Fifty-nine percent of patients received prokinetic therapy at the time of placement. Thirty-nine tube placements were attempted. Sixty-nine percent of referrals for post-pyloric tube placement resulted in successful placement. X-ray films were requested for 22% of all attempted post-pyloric placements. Less than half of nasogastric tubes were successfully passed, although none of these required X-ray confirmation. The mean cost per tube insertion attempt was 111 pounds. This system confers advantages, particularly in terms of post-pyloric tube placement, even at this early stage of implementation. A reduction in clinical risk and cost avoidance related to X-ray exposure, the need for endoscopic tube placement and parenteral nutrition have been achieved. The implementation of this system should be considered in other centres.

  7. CHANDRA ACIS SURVEY OF X-RAY POINT SOURCES IN NEARBY GALAXIES. II. X-RAY LUMINOSITY FUNCTIONS AND ULTRALUMINOUS X-RAY SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Song; Qiu, Yanli; Liu, Jifeng [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Bregman, Joel N., E-mail: songw@bao.ac.cn, E-mail: jfliu@bao.ac.cn [University of Michigan, Ann Arbor, MI 48109 (United States)

    2016-09-20

    Based on the recently completed Chandra /ACIS survey of X-ray point sources in nearby galaxies, we study the X-ray luminosity functions (XLFs) for X-ray point sources in different types of galaxies and the statistical properties of ultraluminous X-ray sources (ULXs). Uniform procedures are developed to compute the detection threshold, to estimate the foreground/background contamination, and to calculate the XLFs for individual galaxies and groups of galaxies, resulting in an XLF library of 343 galaxies of different types. With the large number of surveyed galaxies, we have studied the XLFs and ULX properties across different host galaxy types, and confirm with good statistics that the XLF slope flattens from lenticular ( α ∼ 1.50 ± 0.07) to elliptical (∼1.21 ± 0.02), to spirals (∼0.80 ± 0.02), to peculiars (∼0.55 ± 0.30), and to irregulars (∼0.26 ± 0.10). The XLF break dividing the neutron star and black hole binaries is also confirmed, albeit at quite different break luminosities for different types of galaxies. A radial dependency is found for ellipticals, with a flatter XLF slope for sources located between D {sub 25} and 2 D {sub 25}, suggesting the XLF slopes in the outer region of early-type galaxies are dominated by low-mass X-ray binaries in globular clusters. This study shows that the ULX rate in early-type galaxies is 0.24 ± 0.05 ULXs per surveyed galaxy, on a 5 σ confidence level. The XLF for ULXs in late-type galaxies extends smoothly until it drops abruptly around 4 × 10{sup 40} erg s{sup −1}, and this break may suggest a mild boundary between the stellar black hole population possibly including 30 M {sub ⊙} black holes with super-Eddington radiation and intermediate mass black holes.

  8. Parameter estimation in X-ray astronomy

    International Nuclear Information System (INIS)

    Lampton, M.; Margon, B.; Bowyer, S.

    1976-01-01

    The problems of model classification and parameter estimation are examined, with the objective of establishing the statistical reliability of inferences drawn from X-ray observations. For testing the validities of classes of models, the procedure based on minimizing the chi 2 statistic is recommended; it provides a rejection criterion at any desired significance level. Once a class of models has been accepted, a related procedure based on the increase of chi 2 gives a confidence region for the values of the model's adjustable parameters. The procedure allows the confidence level to be chosen exactly, even for highly nonlinear models. Numerical experiments confirm the validity of the prescribed technique.The chi 2 /sub min/+1 error estimation method is evaluated and found unsuitable when several parameter ranges are to be derived, because it substantially underestimates their joint errors. The ratio of variances method, while formally correct, gives parameter confidence regions which are more variable than necessary

  9. Endovascular management of delayed post-pancreatectomy haemorrhage

    International Nuclear Information System (INIS)

    Pottier, Edwige; Ronot, Maxime; Vilgrain, Valerie; Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise; Sauvanet, Alain

    2016-01-01

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  10. Endovascular management of delayed post-pancreatectomy haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, Edwige [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); Ronot, Maxime; Vilgrain, Valerie [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); University Paris Diderot, Paris (France); INSERM U1149, centre de recherche biomedicale Bichat-Beaujon, CRB3, Paris (France); Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise [APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France); Sauvanet, Alain [University Paris Diderot, Paris (France); APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France)

    2016-10-15

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  11. Software System for the Calibration of X-Ray Measuring Instruments

    International Nuclear Information System (INIS)

    Gaytan-Gallardo, E.; Tovar-Munoz, V. M.; Cruz-Estrada, P.; Vergara-Martinez, F. J.; Rivero-Gutierrez, T.

    2006-01-01

    A software system that facilities the calibration of X-ray measuring instruments used in medical applications is presented. The Secondary Standard Dosimetry Laboratory (SSDL) of the Nuclear Research National Institute in Mexico (ININ in Spanish), supports activities concerning with ionizing radiations in medical area. One of these activities is the calibration of X-ray measuring instruments, in terms of air kerma or exposure by substitution method in an X-ray beam at a point where the rate has been determined by means of a standard ionization chamber. To automatize this process, a software system has been developed, the calibration system is composed by an X-ray unit, a Dynalizer IIIU X-ray meter by RADCAL, a commercial data acquisition card, the software system and the units to be tested and calibrated. A quality control plan has been applied in the development of the software system, ensuring that quality assurance procedures and standards are being followed

  12. Thermodynamics of post-growth annealing of cadmium zinc telluride nuclear radiation detectors

    Science.gov (United States)

    Adams, Aaron Lee

    Nuclear Radiation Detectors are used for detecting, tracking, and identifying radioactive materials which emit high-energy gamma and X-rays. The use of Cadmium Zinc Telluride (CdZnTe) detectors is particularly attractive because of the detector's ability to operate at room temperature and measure the energy spectra of gamma-ray sources with a high resolution, typically less than 1% at 662 keV. While CdZnTe detectors are acceptable imperfections in the crystals limit their full market potential. One of the major imperfections are Tellurium inclusions generated during the crystal growth process by the retrograde solubility of Tellurium and Tellurium-rich melt trapped at the growth interface. Tellurium inclusions trap charge carriers generated by gamma and X-ray photons and thus reduce the portion of generated charge carriers that reach the electrodes for collection and conversion into a readable signal which is representative of the ionizing radiation's energy and intensity. One approach in resolving this problem is post-growth annealing which has the potential of removing the Tellurium inclusions and associated impurities. The goal of this project is to use experimental techniques to study the thermodynamics of Tellurium inclusion migration in post-growth annealing of CdZnTe nuclear detectors with the temperature gradient zone migration (TGZM) technique. Systematic experiments will be carried out to provide adequate thermodynamic data that will inform the engineering community of the optimum annealing parameters. Additionally, multivariable correlations that involve the Tellurium diffusion coefficient, annealing parameters, and CdZnTe properties will be analyzed. The experimental approach will involve systematic annealing experiments (in Cd vapor overpressure) on different sizes of CdZnTe crystals at varying temperature gradients ranging from 0 to 60°C/mm (used to migrate the Tellurium inclusion to one side of the crystal), and at annealing temperatures ranging

  13. Quality control of diagnostic x-ray equipment and film processing

    International Nuclear Information System (INIS)

    1993-01-01

    According to the section 40 of the Radiation Act (592/92), the licensee is required in Finland to make the arrangements to control the function of the radiation equipment and related facilities used for medical procedures. The guide explains how quality control can be organized for diagnostic x-ray equipment. It also gives recommendations for constancy tests for conventional x-ray radiographic and fluoroscopic equipment and for film processing. The recommendations are based on the publications and statements of the International Committee for Radiation Protection (ICRP) and standardization organizations. The intention is that the operators of x-ray equipment or the maintenance personnel are able to perform the quality control tests presented in the guide

  14. Polarization ray tracing in anisotropic optically active media. I. Algorithms

    International Nuclear Information System (INIS)

    McClain, S.C.; Hillman, L.W.; Chipman, R.A.

    1993-01-01

    Procedures for performing polarization ray tracing through birefringent media are presented in a form compatible with the standard methods of geometrical ray tracing. The birefringent materials treated include the following: anisotropic optically active materials such as quartz, non-optically active uniaxial materials such as calcite, and isotropic optically active materials such as mercury sulfide and organic liquids. Refraction and reflection algorithms are presented that compute both ray directions and wave directions. Methods for computing polarization modes, refractive indices, optical path lengths, and Fresnel transmission and reflection coefficients are also specified. A numerical example of these algorithms is given for analyzing the field of view of a quartz rotator. 37 refs., 3 figs

  15. Ray tracing package through a lens system and a spectrometer

    International Nuclear Information System (INIS)

    Zurro, B.; King, P.W.; Lazarus, E.A.

    1980-03-01

    To study the light collection optics of the ISX-B two-dimensional (2-D) Thomson scattering system, we have implemented in the Oak Ridge National Laboratory (ORNL) Fusion Energy Division (FED) PDP-10 two computer programs, LENS and SPECT, that trace rays through a lens system and a spectrometer, respectively. The lens package follows the path of any kind of ray (meridional or skew) through a centered optical system formed by an arbitrary number of spherical surfaces. The spectrometer package performs geometrical ray tracing through a Czerney-Turner spectrometer and can be easily modified for studying any other configuration. Contained herein is a description of the procedures followed and a listing of the computer programs

  16. Simultaneous X-ray diffraction from multiple single crystals of macromolecules

    DEFF Research Database (Denmark)

    Paithankar, Karthik S.; Sørensen, Henning Osholm; Wright, Jonathan P.

    2011-01-01

    The potential in macromolecular crystallography for using multiple crystals to collect X-ray diffraction data simultaneously from assemblies of up to seven crystals is explored. The basic features of the algorithms used to extract data and their practical implementation are described. The procedure...

  17. Effects of ablation energy and post-irradiation on the structure and properties of titanium dioxide nanomaterials

    International Nuclear Information System (INIS)

    Guillén, G. García; Shaji, S.; Palma, M. I. Mendivil; Avellaneda, D.; Castillo, G.A.; Roy, T.K. Das

    2017-01-01

    Highlights: • Highlights • TiO_2 nanomaterials were prepared by PLALM. • Characterized these nanomaterials using TEM, XPS, XRD, optical and luminescence measurements. • Morphology of these nanomaterials were dependent on ablation wavelength, fluence and post-irradiation time. • Laser post irradiation modified the size, morphology and structure of these TiO_2 nanomaterials. - Abstract: Nanomaterials of titanium oxide were prepared by pulsed laser ablation of a titanium metal target in distilled water. The ablation was performed at different laser energy (fluence) using a nanosecond pulsed Nd:YAG laser output of 1064 and 532 nm. A post-irradiation of titanium oxide nanocolloids obtained by ablation using 532 nm was carried out to explore its effects on the structure and properties. Analysis of morphology, crystalline phase, elemental composition, chemical state, optical and luminescent properties were performed using Transmission Electron Microscopy (TEM), X-Ray Diffraction (XRD), X-Ray Photoelectron Spectroscopy (XPS), UV–-vis absorption spectroscopy and room temperature photoluminescence spectroscopy. It was found that titanium oxide nanomaterial morphologies and optical properties were determined by ablation wavelength and fluence. Further, nanocolloids prepared by 532 nm ablation showed a crystalline phase change by laser post-irradiation. The results showed that pulsed laser ablation in liquid as well as post-irradiation were effective in modifying the final structure and properties of titanium oxide nanocolloids.

  18. Effects of ablation energy and post-irradiation on the structure and properties of titanium dioxide nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Guillén, G. García [Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y Eléctrica, San Nicolás de los Garza, Nuevo León 66455, México (Mexico); Shaji, S., E-mail: sshajis@yahoo.com [Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y Eléctrica, San Nicolás de los Garza, Nuevo León 66455, México (Mexico); Universidad Autónoma de Nuevo León-CIIDIT, Apodaca, Nuevo León, México (Mexico); Palma, M. I. Mendivil [Centro de Investigación en Materiales Avanzados (CIMAV), Unidad Monterrey, PIIT, Apodaca, Nuevo León, México (Mexico); Avellaneda, D.; Castillo, G.A.; Roy, T.K. Das [Universidad Autónoma de Nuevo León, Facultad de Ingeniería Mecánica y Eléctrica, San Nicolás de los Garza, Nuevo León 66455, México (Mexico); and others

    2017-05-31

    Highlights: • Highlights • TiO{sub 2} nanomaterials were prepared by PLALM. • Characterized these nanomaterials using TEM, XPS, XRD, optical and luminescence measurements. • Morphology of these nanomaterials were dependent on ablation wavelength, fluence and post-irradiation time. • Laser post irradiation modified the size, morphology and structure of these TiO{sub 2} nanomaterials. - Abstract: Nanomaterials of titanium oxide were prepared by pulsed laser ablation of a titanium metal target in distilled water. The ablation was performed at different laser energy (fluence) using a nanosecond pulsed Nd:YAG laser output of 1064 and 532 nm. A post-irradiation of titanium oxide nanocolloids obtained by ablation using 532 nm was carried out to explore its effects on the structure and properties. Analysis of morphology, crystalline phase, elemental composition, chemical state, optical and luminescent properties were performed using Transmission Electron Microscopy (TEM), X-Ray Diffraction (XRD), X-Ray Photoelectron Spectroscopy (XPS), UV–-vis absorption spectroscopy and room temperature photoluminescence spectroscopy. It was found that titanium oxide nanomaterial morphologies and optical properties were determined by ablation wavelength and fluence. Further, nanocolloids prepared by 532 nm ablation showed a crystalline phase change by laser post-irradiation. The results showed that pulsed laser ablation in liquid as well as post-irradiation were effective in modifying the final structure and properties of titanium oxide nanocolloids.

  19. A ``perfect'' Late Phase Flare Loop: X-ray And Radio Studies

    Science.gov (United States)

    Bain, Hazel; Fletcher, L.

    2009-05-01

    We present observations of a GOES X3.1 class flare which occurred on the 24th August 2002. The event was observed by a number of instruments including RHESSI, TRACE and NoRH. This flare is particularly interesting due to its position and orientation on the west limb of the Sun. The flare appears to be perpendicular to the line of sight making it possible to ascertain the geometrical parameters of the post flare arcade loops. We investigate the decay phase of the flare by comparing X-ray and radio observations of the post flare arcade loops with models of soft x-ray and thermal gyrosynchrotron emission to characterise the electron distribution present within the loop. HMB gratefully acknowledges the support of an SPD and STFC studentship. LF gratefully acknowledges the support of an STFC Rolling Grant, and financial support by the European Commission through the SOLAIRE Network (MTRN-CT_2006-035484)

  20. Determination of silver in ancient coins by X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Pairatana, C.

    1976-01-01

    45 coins of late Ayudhaya and Bangkok periods was analyzed quantitatively by x-ray fluorescence technique using radioisotopic sources Pm - 147/A1 and Am - 241. The fluorescence x-rays were detected by Lithium drifted silicon detector and 1024 channels pulse height analyzer. The procedure was laid a stress on non-destructive methods which could be utilized for analysing various kinds of antiquities and work of arts such as metals, alloys, pottery, ceramics, paper, textile, wood etc