WorldWideScience

Sample records for ray test program

  1. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  2. VETA-I x ray test analysis

    Science.gov (United States)

    Brissenden, R. J. V.; Chartas, G.; Freeman, M. D.; Hughes, J. P.; Kellogg, E. M.; Podgorski, W. A.; Schwartz, D. A.; Zhao, P.

    1992-01-01

    This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report.

  3. FFTF reactor-characterization program: gamma-ray measurements and shield characterization

    International Nuclear Information System (INIS)

    Bunch, W.L.; Moore, F.S. Jr.

    1983-02-01

    A series of experiments is to be made during the acceptance test program of the Fast Flux Test Facility (FFTF) to measure the gamma ray characteristics of the Fast Test Reactor (FTR) and to establish the performance characteristics of the reactor shield. These measurements are a part of the FFTF Reactor Characterization Program (RCP). Detailed plans have been developed for these experiments. During the initial phase of the Characteristics Program, which will be carried out in the In-Reactor Thimble (IRT), both active and passive measurement methods will be employed to obtain as much information concerning the gamma ray environment as is practical. More limited active gamma ray measurements also will be made in the Vibration Open Test Assembly (VOTA)

  4. Calculation of cosmic ray induced single event upsets: Program CRUP (Cosmic Ray Upset Program)

    Science.gov (United States)

    Shapiro, P.

    1983-09-01

    This report documents PROGRAM CRUP, COSMIC RAY UPSET PROGRAM. The computer program calculates cosmic ray induced single-event error rates in microelectronic circuits exposed to several representative cosmic-ray environments.

  5. Single event upset test programs

    International Nuclear Information System (INIS)

    Russen, L.C.

    1984-11-01

    It has been shown that the heavy ions in cosmic rays can give rise to single event upsets in VLSI random access memory devices (RAMs). Details are given of the programs written to test 1K, 4K, 16K and 64K memories during their irradiation with heavy charged ions, in order to simulate the effects of cosmic rays in space. The test equipment, which is used to load the memory device to be tested with a known bit pattern, and subsequently interrogate it for upsets, or ''flips'', is fully described. (author)

  6. TIM, a ray-tracing program for METATOY research and its dissemination

    Science.gov (United States)

    Lambert, Dean; Hamilton, Alasdair C.; Constable, George; Snehanshu, Harsh; Talati, Sharvil; Courtial, Johannes

    2012-03-01

    TIM (The Interactive METATOY) is a ray-tracing program specifically tailored towards our research in METATOYs, which are optical components that appear to be able to create wave-optically forbidden light-ray fields. For this reason, TIM possesses features not found in other ray-tracing programs. TIM can either be used interactively or by modifying the openly available source code; in both cases, it can easily be run as an applet embedded in a web page. Here we describe the basic structure of TIM's source code and how to extend it, and we give examples of how we have used TIM in our own research. Program summaryProgram title: TIM Catalogue identifier: AEKY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEKY_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License No. of lines in distributed program, including test data, etc.: 124 478 No. of bytes in distributed program, including test data, etc.: 4 120 052 Distribution format: tar.gz Programming language: Java Computer: Any computer capable of running the Java Virtual Machine (JVM) 1.6 Operating system: Any; developed under Mac OS X Version 10.6 RAM: Typically 145 MB (interactive version running under Mac OS X Version 10.6) Classification: 14, 18 External routines: JAMA [1] (source code included) Nature of problem: Visualisation of scenes that include scene objects that create wave-optically forbidden light-ray fields. Solution method: Ray tracing. Unusual features: Specifically designed to visualise wave-optically forbidden light-ray fields; can visualise ray trajectories; can visualise geometric optic transformations; can create anaglyphs (for viewing with coloured "3D glasses") and random-dot autostereograms of the scene; integrable into web pages. Running time: Problem-dependent; typically seconds for a simple scene.

  7. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  8. Programs and procedures for assessing quality of spectral gamma-ray borehole data for the UGTA

    International Nuclear Information System (INIS)

    Conaway, J.G.

    1998-01-01

    This report describes the procedures and computer programs used to process spectral gamma-ray borehole logging data in the UGTA (UnderGround Test Area) program at the NTS (Nevada Test Site) to assess data quality. These programs and procedures were used to analyze data from five boreholes in the UGTA program. Development of these computer programs and procedures required considerable effort and the primary purpose of this report is to provide continuity with future activities related to spectral gamma-ray borehole logging in the UGTA program. This is especially important because of the long time interval between cessation of logging in April, 1996 and the next round of activity, which has not yet occurred. This report should also be useful if any quality control issues arise regarding past or forthcoming spectral gamma-ray log analyses. In the characterization work underway at the Nevada Test Site Underground Test Area, the logging contractor, Western Atlas, agreed to identify five artificial nuclides based on their gamma-ray signatures. Those nuclides are 60 Co, 106 Ru, 125 Sb, 134 Cs, and 137 Cs. In the case of 106 Ru, which is not a gamma emitter, any detected gamma rays come from the daughter nuclide 106 Rh which has a half-life of 30 s. With such a short half-life, 106 Rh can be considered to be in equilibrium with 106 Ru under most conditions so the result is the same as if the gamma rays were emitted by the 106 Ru. The Western Atlas spectral gamma-ray curve plots from a given borehole present detailed qualitative information on the apparent distribution of natural and artificial nuclides with depth in the borehole. The computer programs and procedures described in this report were used to provide a quality analysis of the contractor's processed data and to work with the contractor to validate and/or refine their existing automatic processing. This was done using a procedure that was developed and tested successfully in earlier work at the NTS; the revised

  9. RAY TRACING IMPLEMENTATION IN JAVA PROGRAMMING LANGUAGE

    OpenAIRE

    Aybars UĞUR; Mustafa TÜRKSEVER

    2002-01-01

    In this paper realism in computer graphics and components providing realism are discussed at first. It is mentioned about illumination models, surface rendering methods and light sources for this aim. After that, ray tracing which is a technique for creating two dimensional image of a three-dimensional virtual environment is explained briefly. A simple ray tracing algorithm was given. "SahneIzle" which is a ray tracing program implemented in Java programming language which ...

  10. RAY TRACING IMPLEMENTATION IN JAVA PROGRAMMING LANGUAGE

    Directory of Open Access Journals (Sweden)

    Aybars UĞUR

    2002-01-01

    Full Text Available In this paper realism in computer graphics and components providing realism are discussed at first. It is mentioned about illumination models, surface rendering methods and light sources for this aim. After that, ray tracing which is a technique for creating two dimensional image of a three-dimensional virtual environment is explained briefly. A simple ray tracing algorithm was given. "SahneIzle" which is a ray tracing program implemented in Java programming language which can be used on the internet is introduced. As a result, importance of network-centric ray tracing software is discussed.

  11. Applications of the Basic programming language in X-ray spectrometry

    International Nuclear Information System (INIS)

    Diaz-Guerra, J.P.; Roca, M.

    1981-01-01

    An assembly of programs written in ''Basic'' language and related with the calculation needs at the X-ray spectrometry laboratory of the Spanish J.E.N. has been developed. The principal problems considered, concerning the X-ray fluorescence technique, are the following: selection of the instrumental parameters; correction of the effects due to the dead time, background and spectral interferences; fitting of polynomial functions, which relate the variables intensity-concentration; application of some empirical-mathematical methods (Lucas-Tooth, Beattie and Brissey and Tertian procedures) to the correction of the inter-element effects; addition method, and statistical treatment of the results (correlation coefficient and ''F'' and ''t'' tests). Likewise, programs for the computation of spacings from powder diffraction patterns (Debye-Scherrer and counter diffractometer procedures) have been written. The proposed programs run following conversational patterns, in which different possibilities and incidences have been foreseen. (author)

  12. Test facility for astronomical x-ray optics

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Lewis, Robert A.; Bordas, J.

    1990-01-01

    Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earth's atmosphere. These devices require a large collection aperture and the imaging of an x-ray source that is essentially placed at infinity. The ideal testing system for these optical elements has to appro......Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earth's atmosphere. These devices require a large collection aperture and the imaging of an x-ray source that is essentially placed at infinity. The ideal testing system for these optical elements has...... to approximate that encountered under working conditions; however, the testing of these optical elements is notoriously difficult with conventional x-ray generators. Synchrotron radiation (SR) sources are sufficiently brilliant to produce a nearly perfect parallel beam over a large area while still retaining...... a flux considerably higher than that available from conventional x-ray generators. A facility designed for the testing of x-ray optics, particularly in connection with x-ray telescopes, is described. It is proposed that this facility will be accommodated at the Synchrotron Radiation Source...

  13. ParShield: A computer program for calculating attenuation parameters of the gamma rays and the fast neutrons

    International Nuclear Information System (INIS)

    Elmahroug, Y.; Tellili, B.; Souga, C.; Manai, K.

    2015-01-01

    Highlights: • Description of the theoretical method used by the ParShield program. • Description of the ParShield program. • Test and validation the ParShield program. - Abstract: This study aims to present a new computer program called ParShield which determines the neutron and gamma-ray shielding parameters. This program can calculate the total mass attenuation coefficients (μ t ), the effective atomic numbers (Z eff ) and the effective electron densities (N eff ) for gamma rays and it can also calculate the effective removal cross-sections (Σ R ) for fast neutrons for mixtures and compounds. The results obtained for the gamma rays by using ParShield were compared with the results calculated by the WinXcom program and the measured results. The obtained values of (Σ R ) were tested by comparing them with the measured results,the manually calculated results and with the results obtained by using MERCSFN program and an excellent agreement was found between them. The ParShield program can be used as a fast and effective tool to choose and compare the shielding materials, especially for the determination of (Z eff ) and (N eff ), there is no other programs in the literature which can calculate

  14. 78 FR 63823 - Energy Conservation Program: Test Procedures for Television Sets

    Science.gov (United States)

    2013-10-25

    ..., Building Technologies Program, EE-2J, 1000 Independence Avenue SW., Washington, DC 20585-0121. Telephone... test signals for test content and was geared heavily for older screen technologies like cathode ray... tested. For example, in Figure 5, testing would not be required with Eco mode both enabled and disabled...

  15. Overview of the GEM muon system cosmic ray test program at the SSCL

    International Nuclear Information System (INIS)

    Milner, E.C.

    1993-04-01

    Muon track resolution exceeding 75-μm per plane is one of the main strengths of the GEM detector design, and will be crucial in searches for Higgs Bosons, heavy Z-Bosons, technicolor, and supersymmetry. Achieving this resolution coal requires improved precision in muon chambers and their alignment. A cosmic ray test stand known as the Texas Test Rio, (TTR) has been created at the SSCL for studying candidate GEM muon chamber technologies. Test results led to selecting Cathode Strip Chambers (CSC) as the GEM muon system baseline chamber technology

  16. NASA X-Ray Observatory Completes Tests Under Harsh Simulated Space Conditions

    Science.gov (United States)

    1998-07-01

    the Operations Control Center after launch. "As is usually the case, we identified a few issues to be resolved before launch," said Wojtalik. "Overall, however, the observatory performed exceptionally well." The observatory test team discovered a mechanical problem with one of the primary science instruments, the Imaging Spectrometer. A door protecting the instrument did not function when commanded by test controllers. "We do these tests to check and double check every aspect of satellite operation that could affect the ultimate success of the science mission," said Craig Staresinich, TRW Advanced X-ray Astrophysics Facility program manager. "Discovering a problem now is a success. Discovering a problem later, after launch, would be a failure." A team of NASA and contractor engineers are studying the mechanical problem and developing a plan to correct it. The instrument will be sent back to its builder, Lockheed-Martin Astronautics in Denver, Colo., where it will be repaired while the rest of the observatory continues other testing. This should still allow an on-time delivery of the observatory to NASA's Kennedy Space Center, Fla., in August, where it will be readied for launch in January. With a resolving power 10 times greater than previous X-ray telescopes, the new X-ray observatory will provide scientists with views of previously invisible X-ray sources, including black holes, exploding stars and interstellar gasses. The third of NASA's Great Observatories, it will join the Compton Gamma Ray Observatory and the Hubble Space Telescope in orbit. The Advanced X-ray Astrophysics Facility program is managed by the Marshall Center for the Office of Space Science, NASA Headquarters, Washington, D.C. TRW Space & Electronics Group is assembling the observatory and doing verification testing. The Advanced X-ray Astrophysics Facility Operations Control Center is operated by the Smithsonian Astrophysical Observatory. Using glass purchased from Schott Glaswerke, Mainz, Germany

  17. The IHS diagnostic X-ray equipment radiation protection program

    International Nuclear Information System (INIS)

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-01-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload

  18. X-ray testing of fiber composite plastics

    International Nuclear Information System (INIS)

    Altmann, O.; Lembke, B.

    1984-01-01

    Besides the ultrasonic test, X-raying is the most important non-destructive test procedure for supporting fibre composite structures. This report presents some auxiliary means and test results regarding the limits of fault detectibility during the X-raying of fiber composite structures, preferrably carbon fiber laminates (CFRP). (orig.) [de

  19. The NASA cosmic ray program for the 1990's and beyond Interim report of the NASA Cosmic Ray Program Working Group

    International Nuclear Information System (INIS)

    Ahlen, S.P.; Binns, W.R.; Cherry, M.L.; Gaisser, T.K.; Jones, W.V.; Ling, J.C.; Mewaldt, R.A.; Muller, D.; Ormes, J.O.; Ramaty, R.; Stone, E.C.; Waddington, C.J.; Webber, W.R.; Miedenbeck, M.E.

    1990-01-01

    The interim report of the 1989 NASA Cosmic Ray Program Working Group is presented. The report summarizes the cosmic ray program for the 1990's, including the recently approved ACE, Astromag, HNC, POEMS, and SAMPEX missions, as well as other key elements of the program. New science themes and candidate missions are identified for the first part of the 21st Century, including objectives that might be addressed as part of the Human Exploration Initiative. Among the suggested new thrusts for the 21st century are: an Interstellar Probe into the nearby interstellar medium; a Lunar-Based Calorimeter to measure the cosmic ray composition near ∼10 16 eV; high precision element and isotope spectroscopy of ultraheavy (Z≥30) elements; and new, more sensitive, studies of impulsive solar flare events

  20. The introduction of compulsory compliance testing of medical diagnostic x-ray equipment in Western Australia

    International Nuclear Information System (INIS)

    Rafferty, M. W.; Jacob, C. S.

    1995-01-01

    Performance testing of medical diagnostic X-ray equipment can reveal equipment faults which, while not always clinically detectable, may contribute to reduced image quality and unnecessary radiation exposure of both patients and staff. Routine testing of such equipment is highly desirable to identify such faults and allows them to be rectified. The Radiological council of Western Australia is moving towards requiring compulsory compliance testing of all (new and existing) medical diagnostic X-ray equipment that all new mobile radiographic and new mammographic X-ray equipment be issued with a compliance test certificate as a prerequisite for registration. Workbooks which provide details of the tests required and recommended test methods have been prepared for medical radiographic (mobile and fixed), fluoroscopic and mammographic X-ray equipment. It is intended that future workbooks include details of the tests and methods for dental and computed tomography X-ray units. The workbooks are not limited to the compliance testing of items as specified in the Regulations, but include tests for other items such as film processing, darkrooms and image quality (for fluoroscopic equipment). Many of the workbook tests could be used within a regular quality assurance program for diagnostic X-ray equipment. Persons who conduct such compliance tests will need to be licensed and have all test certificates endorsed by a qualified expert. Suitable training and assessment of compliance testers will be required. Notification of such tests (including non-compliant items and corrective actions taken) will be required by the Radiological Council as a condition of equipment registration. 9 refs

  1. Performing Chest X-Rays at Inspiration in Uncooperative Children: The Effect of Exercises with a Training Program for Radiology Technicians

    International Nuclear Information System (INIS)

    Langen, H.J.; Sengenberger, C.; Bielmeier, J.; Jocher, R.; Kohlhauser-Vollmuth, Ch.; Eschmann, M.

    2014-01-01

    It is difficult to acquire a chest X-ray of a crying infant at maximum inspiration. A computer program was developed for technician training. Method. Video clips of 3 babies were used and the moment of deepest inspiration was determined in the single-frame view. 12 technicians simulated chest radiographs at normal video speed by pushing a button. The computer program stopped the video and calculated the period of time to the optimal instant for a chest X-ray. Demonstration software can be tested at website online. Every technician simulated 10 chest X-rays for each of the 3 video clips. The technicians then spent 40 minutes practicing performing chest X-rays at optimal inspiration. The test was repeated after 5, 20, and 40 minutes of practice. Results. 6 participants showed a significant improvement after exercises (collective 1). Deviation from the optimal instant for taking an X-ray at inspiration decreased from 0.39 to 0.22 s after 40 min of practice. 6 technicians showed no significant improvement (collective 2). Deviation decreased from a low starting value of 0.25 s to 0.21 s. Conclusion. The tested computer program improves the ability of radiology technicians to take a chest X-ray at optimal inspiration in a crying child

  2. A Test Facility For Astronomical X-Ray Optics

    DEFF Research Database (Denmark)

    Lewis, R. A.; Bordas, J.; Christensen, Finn Erland

    1989-01-01

    Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earths atmosphere. These devices require a large collection aperture and the imaging of an x-ray source which is essentially placed at infinity. The ideal testing system for these optical elements has...... to approximate that encountered under working conditions, however the testing of these optical elements is notoriously difficult with conventional x-ray generators. Synchrotron Radiation (SR) sources are sufficiently brilliant to produce a nearly perfect parallel beam over a large area whilst still retaining...... a flux considerably higher than that available from conventional x-ray generators. A facility designed for the testing of x-ray optics, particularly in connection with x-ray telescopes is described below. It is proposed that this facility will be accommodated at the Synchrotron Radiation Source...

  3. A comparison of three different ray trace programs for x-ray and infrared synchrotron beamline designs

    International Nuclear Information System (INIS)

    Irick, S.C.; Jung, C.R.

    1997-07-01

    There are a number of ray trace programs currently used for the design of synchrotron beamlines. While several of these programs have been written and used mostly within the programmer''s institution, many have also been available to the general public. This paper discusses three such programs. One is a commercial product oriented for the general optical designer (not specifically for synchrotron beamlines). One is designed for synchrotron beamlines and is free with restricted availability. Finally, one is designed for synchrotron beamlines and is used primarily in one institution. The wealth of information from general optical materials and components catalogs is readily available in the commercial program for general optical designs. This makes the design of an infrared beamline easier from the standpoint of component selection. However, this program is not easily configured for synchrotron beamline designs, particularly for a bending magnet source. The synchrotron ray trace programs offer a variety of sources, but generally are not as easy to use from the standpoint of the user interface. This paper shows ray traces of the same beamline Optikwerks, SHADOW, and RAY, and compares the results

  4. CORAM (COsmic RAy Mission): An outreach program one century after Pacini and Hess works

    Energy Technology Data Exchange (ETDEWEB)

    Chiarello, G.; Coluccia, M.R. [Università del Salento, Dipartimento di Matematica e Fisica “Ennio De Giorgi”, Lecce (Italy); INFN - Istituto Nazionale di Fisica Nucleare, Lecce (Italy); Corvaglia, A.; Creti, P. [INFN - Istituto Nazionale di Fisica Nucleare, Lecce (Italy); De Mitri, I.; Panareo, M.; Pinto, C. [Università del Salento, Dipartimento di Matematica e Fisica “Ennio De Giorgi”, Lecce (Italy); INFN - Istituto Nazionale di Fisica Nucleare, Lecce (Italy); Solters, M. [Univeristy of Florida, Department of Physics, Gainesville, FL (United States)

    2013-06-15

    CORAM (COsmic RAy Mission) is an outreach program carried out by INFN and the University of Salento in close collaboration with high schools. Students and their teachers are involved in the design, construction, test and operation of detectors for the measurement of several properties of the cosmic ray flux. The results of a set of measurements, made with a first detector prototype at different altitudes and underground, will be described.

  5. Cosmic rays and tests of fundamental principles

    Science.gov (United States)

    Gonzalez-Mestres, Luis

    2011-03-01

    It is now widely acknowledged that cosmic rays experiments can test possible new physics directly generated at the Planck scale or at some other fundamental scale. By studying particle properties at energies far beyond the reach of any man-made accelerator, they can yield unique checks of basic principles. A well-known example is provided by possible tests of special relativity at the highest cosmic-ray energies. But other essential ingredients of standard theories can in principle be tested: quantum mechanics, uncertainty principle, energy and momentum conservation, effective space-time dimensions, hamiltonian and lagrangian formalisms, postulates of cosmology, vacuum dynamics and particle propagation, quark and gluon confinement, elementariness of particles…Standard particle physics or string-like patterns may have a composite origin able to manifest itself through specific cosmic-ray signatures. Ultra-high energy cosmic rays, but also cosmic rays at lower energies, are probes of both "conventional" and new Physics. Status, prospects, new ideas, and open questions in the field are discussed.

  6. Cosmic rays and tests of fundamental principles

    International Nuclear Information System (INIS)

    Gonzalez-Mestres, Luis

    2011-01-01

    It is now widely acknowledged that cosmic rays experiments can test possible new physics directly generated at the Planck scale or at some other fundamental scale. By studying particle properties at energies far beyond the reach of any man-made accelerator, they can yield unique checks of basic principles. A well-known example is provided by possible tests of special relativity at the highest cosmic-ray energies. But other essential ingredients of standard theories can in principle be tested: quantum mechanics, uncertainty principle, energy and momentum conservation, effective space-time dimensions, hamiltonian and lagrangian formalisms, postulates of cosmology, vacuum dynamics and particle propagation, quark and gluon confinement, elementariness of particles... Standard particle physics or string-like patterns may have a composite origin able to manifest itself through specific cosmic-ray signatures. Ultra-high energy cosmic rays, but also cosmic rays at lower energies, are probes of both 'conventional' and new Physics. Status, prospects, new ideas, and open questions in the field are discussed.

  7. Training program for radiologic technologists for performing chest X-rays at inspiration in uncooperative children

    International Nuclear Information System (INIS)

    Langen, Heinz Jakob; Muras, S.; Kohlhauser-Vollmuth, C.; Stenzel, M.; Beer, M.

    2009-01-01

    A computer program was created to train technologists to perform chest X-rays in crying infants at maximum inspiration. Videos of 4 children were used. Using a computer program, the moment of deepest inspiration was determined in the video in the single frame view. During the normal running video, 14 technologists (3 with significant experience, 3 with little experience and 8 with very little experience in pediatric radiography) simulated a chest radiograph by pushing a button. The computer program stopped the video and the period of time to the optimal moment for a chest x-ray was calculated. Every technologist simulated 10 chest X-rays in each of the 4 video clips. The technologists then trained themselves to perform chest X-rays at optimal inspiration like playing a computer game. After training, the test was repeated. Changes were evaluated by t-test for unpaired samples (level of significance p < 0.05). Although the differences improved in all children, minimal deviation from the optimal moment for taking an X-ray at inspiration occurred in the periodically crying child (0.21 sec before and 0.13 sec after training). In a non-periodically crying infant, the largest differences were shown. The values improved significantly from 0.29 sec to 0.22 sec. The group with substantial experience in pediatric radiology improved significantly from 0.22 sec to 0.15 sec. The group with very little experience in pediatric radiology showed worse results (improvement from 0.29 sec to 0.21 sec). (orig.)

  8. RAY: a ray tracing program in cold magnetized plasma

    International Nuclear Information System (INIS)

    Montes, A.; Souza, L.H.

    1985-01-01

    This report deals with the development of a ray tracing program, that is, the plot of an electromagnetic wave path in a cold magnetized plasma medium. The program was developed based on the validity of the geometrical optics laws to calculate the electromagnetic wave trajectory. This approximation is valid when the wave length is much smaller than the characteristic length of the medium. No hypothesis was made about a particular geometric configuration for the magnetic field, what enables the use of the program in any magnetic confinment scheme. The numerically obtained results were compared with an analytic solution for a particular case (cylindrically symmetric medium, uniform magnetostatic, field along the symmetry axis and ordinary wave) and have shown a satisfactory precision. (Author) [pt

  9. Compliance testing of medical diagnostic x-ray equipment: three years experience of a public hospital in western Australia

    International Nuclear Information System (INIS)

    Tuchyna, T.; Jacob, C.S.

    2000-01-01

    Full text: A formal compliance testing program which began on 1 January 1997 called for all medical and diagnostic x-ray equipment to be tested according to protocols established by the Western Australian Radiological Council. This work describes the impact of the legislation three years post implementation on a major teaching Hospital with 45 x-ray tubes located throughout 37 rooms. Testing is performed prior to scheduled service by licensed compliance testers according to test methods specified in the Western Australian Compliance Testing Workbook, 1997. A dedicated non-invasive x-ray beam analyser is instrumental in accurately determining radiation output parameters of the generator and x-ray tube. Assessment of compliance is determined by a Qualified Expert. Repair and re-testing of non-compliant items is coordinated with service personnel. Notices of non-compliance were received for approximately 60% of the equipment in the Hospital following the equipment' first annual test. Reasons and seriousness of failure varied according to equipment category, test category, equipment use and age. The majority of non-compliance issues were resolved within 90 days. At the end of the third year of testing, approximately 75% of the x-ray units tested met the compliance criteria. The main reasons for non-compliance were found to be design limitations associated with old technology and the current radiation legislation that makes it difficult for older equipment to meet the stringent criteria. The number and categories of failure did not significantly decrease in the second or third years of testing. Exemptions from compliance criteria have been sought for two units on the basis of age and design. Units unable to meet the criteria following several repair attempts or where the cost of repair was deemed not justified, were decommissioned. Formal testing of medical x-ray equipment has demonstrated various non-compliance issues that did not significantly improve during the

  10. Hartman Testing of X-Ray Telescopes

    Science.gov (United States)

    Saha, Timo T.; Biskasch, Michael; Zhang, William W.

    2013-01-01

    Hartmann testing of x-ray telescopes is a simple test method to retrieve and analyze alignment errors and low-order circumferential errors of x-ray telescopes and their components. A narrow slit is scanned along the circumference of the telescope in front of the mirror and the centroids of the images are calculated. From the centroid data, alignment errors, radius variation errors, and cone-angle variation errors can be calculated. Mean cone angle, mean radial height (average radius), and the focal length of the telescope can also be estimated if the centroid data is measured at multiple focal plane locations. In this paper we present the basic equations that are used in the analysis process. These equations can be applied to full circumference or segmented x-ray telescopes. We use the Optical Surface Analysis Code (OSAC) to model a segmented x-ray telescope and show that the derived equations and accompanying analysis retrieves the alignment errors and low order circumferential errors accurately.

  11. DISCRETIZATION APPROACH USING RAY-TESTING MODEL IN PARTING LINE AND PARTING SURFACE GENERATION

    Institute of Scientific and Technical Information of China (English)

    HAN Jianwen; JIAN Bin; YAN Guangrong; LEI Yi

    2007-01-01

    Surface classification, 3D parting line, parting surface generation and demoldability analysis which is helpful to select optimal parting direction and optimal parting line are involved in automatic cavity design based on the ray-testing model. A new ray-testing approach is presented to classify the part surfaces to core/cavity surfaces and undercut surfaces by automatic identifying the visibility of surfaces. A simple, direct and efficient algorithm to identify surface visibility is developed. The algorithm is robust and adapted to rather complicated geometry, so it is valuable in computer-aided mold design systems. To validate the efficiency of the approach, an experimental program is implemented. Case studies show that the approach is practical and valuable in automatic parting line and parting surface generation.

  12. Relay test program

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.K.; Kunkel, C.; Shteyngart, S.

    1994-02-01

    This report presents the results of a relay test program conducted by Brookhaven National Laboratory (BNL) under the sponsorship of the US Nuclear Regulatory Commission (NRC). The program is a continuation of an earlier test program the results of which were published in NUREG/CR-4867. The current program was carried out in two phases: electrical testing and vibration testing. The objective was primarily to focus on the electrical discontinuity or continuity of relays and circuit breaker tripping mechanisms subjected to electrical pulses and vibration loads. The electrical testing was conducted by KEMA-Powertest Company and the vibration testing was performed at Wyle Laboratories, Huntsville, Alabama. This report discusses the test procedures, presents the test data, includes an analysis of the data and provides recommendations regarding reliable relay testing

  13. NEWFIT, a computer program for the analysis of alpha, X-ray and gamma-ray spectra

    International Nuclear Information System (INIS)

    Welch, R.B.; Gyger, F.; Jost, D.T.; Gunten, H.R. von; Kraehenbuehl, U.

    1988-01-01

    The computer program NEWFIT has been developed for analysis of gamma-ray, X-ray and alpha spectra. The general shape used for the analysis of activity peaks is a Gaussian function. An exponential tail can be added for use in alpha spectra analysis. The algorithms to analyze the peak shapes and the program operation are presented. Special features include the ability to create realistic peak shapes based on the systematic deviations of the real peaks from the theoretical Gaussian shape, as well as the option to constrain the calculated areas of peaks from a given emitting nuclide to their relative branching ratios. The program is available from the authors. (orig.)

  14. Cosmic-ray test and temperature effects of MRPC

    International Nuclear Information System (INIS)

    Yue Qian; Li Yuanjing; Cheng Jianping; Wang Yi; Li Jin; Lai Yongfang; Li Qinghua; Tang Le

    2004-01-01

    A comic-ray test system has been built for testing the performance of MRPC modules. Some methods have been studied to improve the time resolution of the cosmic-ray test based on this testing system. The time resolutions of about 84 ps and 75 ps can be achieved for MRPC and its reference time, respectively. The temperature effects of MRPC have also been researched and some useful results are obtained. (author)

  15. Cargo container inspection test program at ARPA's Nonintrusive Inspection Technology Testbed

    Science.gov (United States)

    Volberding, Roy W.; Khan, Siraj M.

    1994-10-01

    An x-ray-based cargo inspection system test program is being conducted at the Advanced Research Project Agency (ARPA)-sponsored Nonintrusive Inspection Technology Testbed (NITT) located in the Port of Tacoma, Washington. The test program seeks to determine the performance that can be expected from a dual, high-energy x-ray cargo inspection system when inspecting ISO cargo containers. This paper describes an intensive, three-month, system test involving two independent test groups, one representing the criminal smuggling element and the other representing the law enforcement community. The first group, the `Red Team', prepares ISO containers for inspection at an off-site facility. An algorithm randomly selects and indicates the positions and preparation of cargoes within a container. The prepared container is dispatched to the NITT for inspection by the `Blue Team'. After in-gate processing, it is queued for examination. The Blue Team inspects the container and decides whether or not to pass the container. The shipment undergoes out-gate processing and returns to the Red Team. The results of the inspection are recorded for subsequent analysis. The test process, including its governing protocol, the cargoes, container preparation, the examination and results available at the time of submission are presented.

  16. The LASL gamma-ray burst astronomy program

    International Nuclear Information System (INIS)

    Klebesadel, R.W.; Evans, W.D.; Laros, J.G.

    1981-01-01

    Gamma-ray burst observations performed by LASL began with the identification and initial report of the phenomenon from data acquired by the Vela satellites. The Vela instruments have recorded responses to 73 gamma-ray bursts over a ten-year interval, and are continuing to contribute toward these observations. Similar instrumentation was included aboard the NRL SOLRAD 11 spacecraft. These performed well but suffered an early demise. Recently, the LASL gamma-ray burst astronomy program has been enhanced through the implementation of experiments aboard the Pioneer Venus Orbiter and ISEF-C spacecraft. Both of these experiments are continuing to contribute data vital to trigonometric directional analyses. (orig.)

  17. Computer board for radioactive ray test

    International Nuclear Information System (INIS)

    Zuo Mingfu

    1996-05-01

    The present status of the radioactive-ray test system for industrial applications, the newly designed computer board for overcoming the shortcomings of the current system are described. The functions, measurement principles and the feature of the board as well as the test results for this board are discussed. The board puts together many functions of the radioactive-ray test system, such as energy calibration, MCS, etc.. It also provides many other subordinate practical function such as motor control, ADC and so on. The board summarizes two sets of test parts into one and therefore composes a powerful unit for the system. Not only can it replace all units in a normal test system for signal analysis, signal process, data management, and motor control, but also can be used in more complex test systems, such as those for double source/double energy/double channel testing, multichannel testing, position testing and core positioning, etc.. The board makes the test system more easier to achieve miniaturization, computerization goals, and therefore improves the quality of the test and reduces the cost of the system. (10 refs., 8 figs.)

  18. Computer program for optical systems ray tracing

    Science.gov (United States)

    Ferguson, T. J.; Konn, H.

    1967-01-01

    Program traces rays of light through optical systems consisting of up to 65 different optical surfaces and computes the aberrations. For design purposes, paraxial tracings with astigmation and third order tracings are provided.

  19. Gamma ray shielding: a web based interactive program

    International Nuclear Information System (INIS)

    Subbaiah, K.V.; Senthi Kumar, C.; Sarangapani, R.

    2005-01-01

    A web based interactive computing program is developed using java for quick assessment of Gamma Ray shielding problems. The program addresses usually encountered source geometries like POINT, LINE, CYLINDRICAL, ANNULAR, SPHERICAL, BOX, followed by 'SLAB' shield configurations. The calculation is based on point kernel technique. The source points are randomly sampled within the source volume. From each source point, optical path traversed in the source and shield media up to the detector location is estimated to calculate geometrical and material attenuations, and then corresponding buildup factor is obtained, which accounts for scattered contribution. Finally, the dose rate for entire source is obtained by summing over all sampled points. The application allows the user to select one of the seven regular geometrical bodies and provision exist to give source details such as emission energies, intensities, physical dimensions and material composition. Similar provision is provided to specify shield slab details. To aid the user, atomic numbers, densities, standard build factor materials and isotope list with respective emission energies and intensity for ready reference are given in dropdown combo boxes. Typical results obtained from this program are validated against existing point kernel gamma ray shielding codes. Additional facility is provided to compute fission product gamma ray source strengths based on the fuel type, burn up and cooling time. Plots of Fission product gamma ray source strengths, Gamma ray cross-sections and buildup factors can be optionally obtained, which enable the user to draw inference on the computed results. It is expected that this tool will be handy to all health physicists and radiological safety officers as it will be available on the internet. (author)

  20. A manual to the MAXRAY program library for reflective and dispersive ray tracing

    International Nuclear Information System (INIS)

    Svensson, S.; Nyholm, R.

    1985-07-01

    A general ray tracing program package for reflective and dispersive X-ray optics is described. The package consists of a number of subroutines written in FORTRAN 77 code giving the necessary tools for ray tracing. The program package is available on request from the authors. (authors)

  1. The reference peak areas of the 1995 IAEA test spectra for gamma-ray spectrum analysis programs are absolute and traceable

    CERN Document Server

    Blaauw, M

    1999-01-01

    A previously validated algorithm for absolute peak area determination was used to verify the reference peak areas supplied with the 1995 IAEA test spectra for gamma-ray spectrometry. These reference peak areas turn out to be absolute and traceable to a precision of 0.9%: The reference peak areas are possibly too low by a factor 0.992+-0.009. It is proposed to employ the test spectra and reference areas to validate the peak areas obtained with any algorithm in gamma-ray spectrometry. (author)

  2. Soft X-ray Foucault test: A path to diffraction-limited imaging

    Science.gov (United States)

    Ray-Chaudhuri, A. K.; Ng, W.; Liang, S.; Cerrina, F.

    1994-08-01

    We present the development of a soft X-ray Foucault test capable of characterizing the imaging properties of a soft X-ray optical system at its operational wavelength and its operational configuration. This optical test enables direct visual inspection of imaging aberrations and provides real-time feedback for the alignment of high resolution soft X-ray optical systems. A first application of this optical test was carried out on a Mo-Si multilayer-coated Schwarzschild objective as part of the MAXIMUM project. Results from the alignment procedure are presented as well as the possibility for testing in the hard X-ray regime.

  3. Automatic TV X-ray unit for testing aluminium castings

    International Nuclear Information System (INIS)

    Morgunov, V.I.; Firstov, V.G.; Kisin, V.I.; Savostenok, M.I.

    1989-01-01

    The automatic TV X-ray unit for testing of aluminum alloy castings in a flow is described. The unit includes RAP-150/300 X-ray apparatus and PI-60TK TV X-ray device. The biological protection chamber and the common control board are the main functional units. The tests of the unit have shown that as regards its characteristics it is not worse than its foreign-made analogues, for example, devices of the DP-35 and DP-38 type of the 'Seifert' company

  4. Programs for the automatic gamma-ray measurement with CANBERRA 8100/QUANTA system

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Sakai, Eiji; Kubo, Katsumi.

    1982-07-01

    Some programs have been prepared for the automatic operation of the CANBERRA 8100/QUANTA System for the gamma-ray spectrum measurement. The main parts of these programs are: (1) to collect and record on magnetic disks the data of gamma-ray spectra automatically, while the recorded data are analyzed to estimate the nuclides which generate photopeaks of spectra and to calculate those concentrations; (2) to draw plotted diagrams of pulse height distributions of gamma-ray spectra data and other data by the additional digital plotter; and etc. (author)

  5. Parallelization for X-ray crystal structural analysis program

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hiroshi [Japan Atomic Energy Research Inst., Tokyo (Japan); Minami, Masayuki; Yamamoto, Akiji

    1997-10-01

    In this report we study vectorization and parallelization for X-ray crystal structural analysis program. The target machine is NEC SX-4 which is a distributed/shared memory type vector parallel supercomputer. X-ray crystal structural analysis is surveyed, and a new multi-dimensional discrete Fourier transform method is proposed. The new method is designed to have a very long vector length, so that it enables to obtain the 12.0 times higher performance result that the original code. Besides the above-mentioned vectorization, the parallelization by micro-task functions on SX-4 reaches 13.7 times acceleration in the part of multi-dimensional discrete Fourier transform with 14 CPUs, and 3.0 times acceleration in the whole program. Totally 35.9 times acceleration to the original 1CPU scalar version is achieved with vectorization and parallelization on SX-4. (author)

  6. Present situation and necessity of computer programmed X-ray equipment

    International Nuclear Information System (INIS)

    Shiraishi, Junji; Hatagawa, Masakatsu

    1989-01-01

    In order to take radiographic photos, it is necessary to know a great deal of information. For example, mA, kV, exposure time, screen, grid, phototimer, etc. In this study, we examined 4 widely-used types computer-programmed X-ray equipment. These computer-assisted processes are designed to look at the data and make programmed individual decisions. The purpose is to reduce the differences in radiographic quality and the risk of retaking caused by the differences in experience among technicians. We concluded that none of them has ideal functions but each can be used as a source supply information, if a little remodeling is done, and we confirm that computer-programmed X-ray equipment is, and will continue to go be, necessary. (author)

  7. ACTIV - a program for automatic processing of gamma-ray spectra

    International Nuclear Information System (INIS)

    Zlokazov, V.B.

    1982-01-01

    Program ACTIV is intended for precise analysis of γ-rays and X-ray spectra and allows the user to carry out the full cycle of automatic processing of a series of spectra, i.e. calibration, automatic peak search, determination of peak positions and areas, identification of the radioisotopes and the transformation of the areas found into masses of isotopes in the irradiated sample. ACTIV uses a complex mathematical technique and is oriented mainly to large computers, but using overlaid loading, it can be run also on small computers like the PDP 11/70. Compared with other similar programs, ACTIV has some advantages in accuracy of peak shape description and in the reliability of the peak search and its least-square analysis. The program can be used for the purpose of activation analysis. The program can analyze spectra with poor statistics and with broad and narrow peaks. (orig.)

  8. Precision test method by x-ray absorbent clay

    International Nuclear Information System (INIS)

    Nakadai, Toru; Matsukawa, Hideyuki; Sekita, Jun-ichiro; Murakoshi, Atsushi.

    1982-01-01

    In X-ray penetration photography of such as welds with reinforcing metal and castings of complex shape, the X-ray absorbent clay developed to eliminate various disadvantages of the conventional absorbents was further studied for better application. The results of the usage are as follows. Because the X-ray absorbent is clay, it is flexible in form, and gives good adhesion to test objects. In the welds and castings mentioned, it is effective for reducing the scattered ray, accordingly, it results in superior images. The following matters are described: contrast in radiographs, the required conditions for X-ray absorbents in general, the properties of the absorbent (absorption coefficient, consistency, density), improvement in radiographs by means of the X-ray absorbent clay (wall thickness compensation, masking, the application together with narrow-field irradiation photography). (Mori, K.)

  9. X-ray imaging in the laser-fusion program

    International Nuclear Information System (INIS)

    McCall, G.H.

    1977-01-01

    Imaging devices which are used or planned for x-ray imaging in the laser-fusion program are discussed. Resolution criteria are explained, and a suggestion is made for using the modulation transfer function as a uniform definition of resolution for these devices

  10. Device for the automatic X-ray testing of welded joints of pipes

    International Nuclear Information System (INIS)

    Ries, K.; Hannoschieck, K.; Rozic, K.M.; Basler, G.

    1979-01-01

    The notification flows of the tested pipes determined by the ultrasonic inspection are transmitted to the X-ray film automatic charger in the X-ray test room. The roll table for the pipes from the ultrasonic inspection to the X-ray test room is provided with an arrangement for weld detection and tube lathe, so that the X-ray films can be set on the corresponding spot by means of a cantilever. (RW) [de

  11. Segmentation of Overlapping Shapes using Test Ray Intersections

    DEFF Research Database (Denmark)

    Rasmusson, Allan

    As the use of digital images have become standard in everyday bioimaging, people are naturally trying to utilize computer algorithms for automating laborious and repetetive image analysis tasks. A preliminary task is the segmentation of structures of interest from digital images. This may in itself....... This may, however, quickly lead to the implementation of complex descriptions of any possible configuration the overlapping shapes may appear in. Presented here is a new approach to segment overlapping shapes which utilizes information gained from probing the image with test rays. Test rays intersections...

  12. Fully automatic X-ray testing in monitoring manufacture - theoretical background and practical experience

    International Nuclear Information System (INIS)

    Roye, W.; Kosanetzky, J.

    1992-01-01

    The trend to ever-increasing automation has not passed by industrial X-ray test technique. As in other fields, there is a development away from manual testing via automated island solutions to including the X-ray test in comprehensive CIM concepts. Wholly new requirements are made of industrial X-ray technique here. High certainty of testing with exact determination of faults and measurements, high test speed by quick handling of the test samples, statistical evaluation with the possibility of process control and sufficient flexibility of the test system are just some of the characteristics of future X-ray test systems. (orig.) [de

  13. Development of ray tracing visualization program by Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Kenji; Otani, Takayuki [Japan Atomic Energy Research Inst., Tokyo (Japan); Hasegawa, Yukihiro

    1997-09-01

    Ray tracing algorithm is a powerful method to synthesize three dimensional computer graphics. In conventional ray tracing algorithms, a view point is used as a starting point of ray tracing, from which the rays are tracked up to the light sources through center points of pixels on the view screen to calculate the intensities of the pixels. This manner, however, makes it difficult to define the configuration of light source as well as to strictly simulate the reflections of the rays. To resolve these problems, we have developed a new ray tracing means which traces rays from a light source, not from a view point, with use of Monte Carlo method which is widely applied in nuclear fields. Moreover, we adopt the variance reduction techniques to the program with use of the specialized machine (Monte-4) for particle transport Monte Carlo so that the computational time could be successfully reduced. (author)

  14. The safety of food products requires X-ray testing

    International Nuclear Information System (INIS)

    Lardiere, C.

    2017-01-01

    Food safety through standards and regulations imposes food products to be tested for the presence of alien elements. So far metal detectors have been used to detect metal parts, now they have been progressively replaced with X-ray scanners that allow the detection of a lot more contaminants. The improvement of algorithms for image processing combined with the availability of ever more powerful PC have led to the routine use of X-ray testing on industrial processes. Technological progress has made X-ray testing more efficient: while previously a power of 500 W was necessary to cross a 10 cm thickness of water, now only 100 W is necessary. The main advantage of X-ray testing is to be able to test food even packed in metal containers and to detect if the container is deformed. Another advantages is to be able to detect a lot of elements like pieces of glass, small stones or bits of bones. The minimal size to be detected is 0.5 mm for stainless steels and 2 mm for glass or bones. Usually metal detectors are set at the end of the production line just before packaging but in some cases they can be included in the line in order to protect the next machine that intervenes to process the food. (A.C.)

  15. The X-Ray Pebble Recirculation Experiment (X-PREX): Facility Description, Preliminary Discrete Element Method Simulation Validation Studies, and Future Test Program

    International Nuclear Information System (INIS)

    Laufer, Michael R.; Bickel, Jeffrey E.; Buster, Grant C.; Krumwiede, David L.; Peterson, Per F.

    2014-01-01

    This paper presents a facility description, preliminary results, and future test program of the new X-Ray Pebble Recirculation Experiment (X-PREX), which is now operational and being used to collect data on the behavior of slow dense granular flows relevant to pebble bed reactor core designs. The X-PREX facility uses digital x-ray tomography methods to track both the translational and rotational motion of spherical pebbles, which provides unique experimental results that can be used to validate discrete element method (DEM) simulations of pebble motion. The validation effort supported by the X-PREX facility provides a means to build confidence in analysis of pebble bed configuration and residence time distributions that impact the neutronics, thermal hydraulics, and safety analysis of pebble bed reactor cores. Preliminary experimental and DEM simulation results are reported for silo drainage, a classical problem in the granular flow literature, at several hopper angles. These studies include conventional converging and novel diverging geometries that provide additional flexibility in the design of pebble bed reactor cores. Excellent agreement is found between the X-PREX experimental and DEM simulation results. Finally, this paper discusses additional studies in progress relevant to the design and analysis of pebble bed reactor cores including pebble recirculation in cylindrical core geometries and evaluation of forces on shut down blades inserted directly into a packed pebble bed. (author)

  16. Visual gamma-ray analysis. VIPF program (WINDOW 95)

    International Nuclear Information System (INIS)

    Yamada, S.

    1998-01-01

    VIsual Peak Fitting (VIPF) program for the analysis of gamma radiation peaks from Ge detectors which works on WINDOWS 95 as an operating system has been developed. Gamma-ray peaks are simulated as Gauss function with 1st- or 2nd-order polynomial function for the background spectrum. Any function can be further added to for parameter fitting. The VIPF program can be obtained through internet by down-loading: http://w3.rri.kyoto-u.ac.jp/~yamada. Details of the program procedure, explanation of the fitting function to be used and peak search routine, and manuals of the code are given. (Ohno, S.)

  17. EOL3 M0 X-ray Tomography Test Results

    CERN Document Server

    Avramidou, R; Bozhko, N; Borisov, A; Goriatchev, V; Goriatchev, S; Gushin, V; Fakhroutdinov, R; Kojine, A; Kononov, A; Larionov, A; Salomatin, Yu I; Schuh, S; Sedykh, Yu; Tchougouev, A

    2001-01-01

    Results of X-ray tomography test of EOL3 module 0 chamber is presented in the note. Peculiarities of the X-ray tomography of the chamber are discussed. Comparison of the tomography results with predictions of the production site measurements is made.

  18. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  19. First indirect x-ray imaging tests with an 88-mm diameter single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Macrander, A. T. [Argonne

    2017-02-01

    Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x - ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100 - micron thickness. The crystal was bonded to a fiber optic plat e (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self - supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream , adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB - based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. Lastly, this single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.

  20. An innovative approach for testing bioinformatics programs using metamorphic testing

    Directory of Open Access Journals (Sweden)

    Liu Huai

    2009-01-01

    Full Text Available Abstract Background Recent advances in experimental and computational technologies have fueled the development of many sophisticated bioinformatics programs. The correctness of such programs is crucial as incorrectly computed results may lead to wrong biological conclusion or misguide downstream experimentation. Common software testing procedures involve executing the target program with a set of test inputs and then verifying the correctness of the test outputs. However, due to the complexity of many bioinformatics programs, it is often difficult to verify the correctness of the test outputs. Therefore our ability to perform systematic software testing is greatly hindered. Results We propose to use a novel software testing technique, metamorphic testing (MT, to test a range of bioinformatics programs. Instead of requiring a mechanism to verify whether an individual test output is correct, the MT technique verifies whether a pair of test outputs conform to a set of domain specific properties, called metamorphic relations (MRs, thus greatly increases the number and variety of test cases that can be applied. To demonstrate how MT is used in practice, we applied MT to test two open-source bioinformatics programs, namely GNLab and SeqMap. In particular we show that MT is simple to implement, and is effective in detecting faults in a real-life program and some artificially fault-seeded programs. Further, we discuss how MT can be applied to test programs from various domains of bioinformatics. Conclusion This paper describes the application of a simple, effective and automated technique to systematically test a range of bioinformatics programs. We show how MT can be implemented in practice through two real-life case studies. Since many bioinformatics programs, particularly those for large scale simulation and data analysis, are hard to test systematically, their developers may benefit from using MT as part of the testing strategy. Therefore our work

  1. PCXMC. A PC-based Monte Carlo program for calculating patient doses in medical x-ray examinations

    International Nuclear Information System (INIS)

    Tapiovaara, M.; Lakkisto, M.; Servomaa, A.

    1997-02-01

    The report describes PCXMC, a Monte Carlo program for calculating patients' organ doses and the effective dose in medical x-ray examinations. The organs considered are: the active bone marrow, adrenals, brain, breasts, colon (upper and lower large intestine), gall bladder, heats, kidneys, liver, lungs, muscle, oesophagus, ovaries, pancreas, skeleton, skin, small intestine, spleen, stomach, testes, thymes, thyroid, urinary bladder, and uterus. (42 refs.)

  2. Design and Initial Tests of the Tracker-Converter ofthe Gamma-ray Large Area Space Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, W.B.; Bagagli, R.; Baldini, L.; Bellazzini, R.; Barbiellini, G.; Belli, F.; Borden, T.; Brez, A.; Brigida, M.; Caliandro, G.A.; Cecchi, C.; Cohen-Tanugi, J.; De; Drell, P.; Favuzzi, C.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Germani, S.; Giannitrapani, R.; Giglietto, N.; /UC, Santa Cruz /INFN, Pisa /Pisa U. /INFN, Trieste /INFN,

    2007-04-16

    The Tracker subsystem of the Large Area Telescope (LAT) science instrument of the Gamma-ray Large Area Space Telescope (GLAST) mission has been completed and tested. It is the central detector subsystem of the LAT and serves both to convert an incident gamma-ray into an electron-positron pair and to track the pair in order to measure the gamma-ray direction. It also provides the principal trigger for the LAT. The Tracker uses silicon strip detectors, read out by custom electronics, to detect charged particles. The detectors and electronics are packaged, along with tungsten converter foils, in 16 modular, high-precision carbon-composite structures. It is the largest silicon-strip detector system ever built for launch into space, and its aggressive design emphasizes very low power consumption, passive cooling, low noise, high efficiency, minimal dead area, and a structure that is highly transparent to charged particles. The test program has demonstrated that the system meets or surpasses all of its performance specifications as well as environmental requirements. It is now installed in the completed LAT, which is being prepared for launch in early 2008.

  3. Underground Nuclear Testing Program, Nevada Test Site

    International Nuclear Information System (INIS)

    1975-09-01

    The Energy Research and Development Administration (ERDA) continues to conduct an underground nuclear testing program which includes tests for nuclear weapons development and other tests for development of nuclear explosives and methods for their application for peaceful uses. ERDA also continues to provide nuclear explosive and test site support for nuclear effects tests sponsored by the Department of Defense. This Supplement extends the Environmental Statement (WASH-1526) to cover all underground nuclear tests and preparations for tests of one megaton (1 MT) or less at the Nevada Test Site (NTS) during Fiscal Year 1976. The test activities covered include numerous continuing programs, both nuclear and non-nuclear, which can best be conducted in a remote area. However, if nuclear excavation tests or tests of yields above 1 MT or tests away from NTS should be planned, these will be covered by separate environmental statements

  4. The Ferrara hard X-ray facility for testing/calibrating hard X-ray focusing telescopes

    Science.gov (United States)

    Loffredo, Gianluca; Frontera, Filippo; Pellicciotta, Damiano; Pisa, Alessandro; Carassiti, Vito; Chiozzi, Stefano; Evangelisti, Federico; Landi, Luca; Melchiorri, Michele; Squerzanti, Stefano

    2005-12-01

    We will report on the current configuration of the X-ray facility of the University of Ferrara recently used to perform reflectivity tests of mosaic crystals and to calibrate the experiment JEM X aboard Integral. The facility is now located in the technological campus of the University of Ferrara in a new building (named LARIX laboratory= LARge Italian X-ray facility) that includes a tunnel 100 m long with, on the sides, two large experimental rooms. The facility is being improved for determining the optical axis of mosaic crystals in Laue configuration, for calibrating Laue lenses and hard X-ray mirror prototypes.

  5. Test of user- and system programs coded in real time languages - requirements on program language and testing tool

    International Nuclear Information System (INIS)

    Hertlin, J.; Mackert, M.

    1979-01-01

    In the present paper the functions are presented, which should be part of a test system for user programs in a higher treat time programming language, taking into account time sequences and competitive processes. As can be shown by the problem of testing, use of higher level real time programming languages renders the task of program development essentially easier, however performance of test procedures without appropriate test systems is very difficult. After the presentation of notions and methods for the testing of programs, general requirements on testing tools are described and the test system functions for a program test, beeing uncritical with respect to time, are placed together. Thereby, for every individual function, the interface between the test system, the program under test, and the residual program-generation system (compiler, binder, operating system, delay-time system, and loader) is given too. For the time-critical test, a series of desirable functions are described, which can be implemented with acceptable expense. (orig.) [de

  6. XMM-Newton X-ray Observatory Guest Observer program (AO-1) at CASA

    Science.gov (United States)

    Skinner, Stephen L.

    2003-01-01

    In this research program, we obtained and analyzed X-ray observations of the Wolf-Rayet (WR) star WR 110 (HD 165688) using the XMM-Newton space-based observatory. Radio observations were also obtained using the Very Large Array (VLA) radio telescope located in New Mexico and operated by the Natl. Radio Astronomy Observatory (NRAO). This star was targeted for observations primarily because it is believed to be a single WR star without a companion. Single WR stars are thought to emit X-rays from cool plasma in shocks distributed throughout their powerful stellar winds. However, there has been little observational work done to test this idea since single WR stars are relatively weak X-ray sources and have been difficult to detect with previous generation telescopes. The launch of XMM-Newton provides a new telescope that is much more sensitive than its predecessors, allowing single WR stars to be studied in detail for the first time. X-ray emission was clearly detected from WR 110. Analysis of its spectrum yields a surprising result. Its X-ray emitting plasma is distributed over a range of temperatures and is dominated by relatively cool plasma with a characteristic temperature T is approximately 6 million K. Such plasma can be explained by existing theoretical wind shock models. However, the spectrum also shows hotter plasma whose temperature is uncertain but is thought to be in excess of T approximately 30 million K. The origin of this hotter plasma is yet unknown, but possible mechanisms are identified

  7. A computer program for automatic gamma-ray spectra analysis

    International Nuclear Information System (INIS)

    Hiromura, Kazuyuki

    1975-01-01

    A computer program for automatic analysis of gamma-ray spectra obtained with a Ge(Li) detector is presented. The program includes a method by comparing the successive values of experimental data for the automatic peak finding and method of leastsquares for the peak fitting. The peak shape in the fitting routine is a 'modified Gaussian', which consists of two different Gaussians with the same height joined at the centroid. A quadratic form is chosen as a function representing the background. A maximum of four peaks can be treated in the fitting routine by the program. Some improvements in question are described. (auth.)

  8. Non-destructive testing of rocket propellant quality using -X-ray radiography

    International Nuclear Information System (INIS)

    Arayaprecha, W.

    1979-01-01

    Currently, X-rays radiography has been used extensively in various industries. In this thesis, X-rays has been used in the study of compaction of rocket propellant. For a rocket, to gain an accurate guidance result, the propellant used must be mixed and compacted thoroughly. The quality control of the production of propellant sticks must be carefully done. In this study of non-destructive quality testing of rocket propellant, at first the ultrasonic rays was used to test its homogeneity. However, because the density of the propellant was too low, the test equipment could not detect any reflected signals from the propellant being tested. Then the new procedure using X-rays radiography was tried. The variables in the test procedure were voltage, amperage and the focal-film distance. Also different types of films were used. The results of this experiment were then used to construct an exposure chart for testing the homogeneity of the rocket propellant. The advantage of this chart is that a tester can use this table with propellant sticks of different sizes if they have similar density to the density specified in the chart. Also, it is not necessary that the mixture of the testing propellant be the same as the ones used to construct this chart

  9. SAVLOC, computer program for automatic control and analysis of X-ray fluorescence experiments

    Science.gov (United States)

    Leonard, R. F.

    1977-01-01

    A program for a PDP-15 computer is presented which provides for control and analysis of trace element determinations by using X-ray fluorescence. The program simultaneously handles data accumulation for one sample and analysis of data from previous samples. Data accumulation consists of sample changing, timing, and data storage. Analysis requires the locating of peaks in X-ray spectra, determination of intensities of peaks, identification of origins of peaks, and determination of a real density of the element responsible for each peak. The program may be run in either a manual (supervised) mode or an automatic (unsupervised) mode.

  10. Low-Energy Microfocus X-Ray Source for Enhanced Testing Capability in the Stray Light Facility

    Science.gov (United States)

    Gaskin, Jessica; O'Dell, Stephen; Kolodziejczak, Jeff

    2015-01-01

    Research toward high-resolution, soft x-ray optics (mirrors and gratings) necessary for the next generation large x-ray observatories requires x-ray testing using a low-energy x-ray source with fine angular size (energy microfocus (approximately 0.1 mm spot) x-ray source from TruFocus Corporation that mates directly to the Stray Light Facility (SLF). MSFC X-ray Astronomy team members are internationally recognized for their expertise in the development, fabrication, and testing of grazing-incidence optics for x-ray telescopes. One of the key MSFC facilities for testing novel x-ray instrumentation is the SLF. This facility is an approximately 100-m-long beam line equipped with multiple x-ray sources and detectors. This new source adds to the already robust compliment of instrumentation, allowing MSFC to support additional internal and community x-ray testing needs.

  11. Testing of x-ray microtomography systems using a traceable geometrical standard

    International Nuclear Information System (INIS)

    Carmignato, S; Dreossi, D; Mancini, L; Tromba, G; Marinello, F; Savio, E

    2009-01-01

    X-ray computed microtomography is an interesting imaging technique for many applications, and is also very promising in the field of coordinate metrology at the micro scale. The main advantage with respect to traditional tactile-probing or optical coordinate measurement systems is that x-ray tomography can acquire dimensional and geometrical data for both inner and outer surfaces, without accessibility restrictions. However, there are no accepted test procedures available so far and measurement uncertainty is unknown in many cases, due to complex and numerous error sources. The paper presents the first results of a test procedure implemented for determining the errors of indication for length measurements of x-ray microtomography systems, using a new reference standard featuring a regular array of inner and outer cylindrical shapes. The developed test method allows the determination of specific characteristics of x-ray microtomography systems and can be used for the correction of systematic errors

  12. VACTIV-DELPHI graphical dialog based program for the analysis of gamma-ray spectra

    International Nuclear Information System (INIS)

    Zlokazov, V.B.

    2002-01-01

    The program VACTIV - Visual ACTIV - has been developed for the analysis of gamma-ray spectra and is a standard graphical dialog based Windows XX application, driven by a menu, mouse and keyboard. On the one hand, it is a conversion of an existing Fortran program ACTIV to the DELPHI-5 language; on the other hand, it is a transformation of the sequential syntax of Fortran programming to a new object-oriented style, based on the organization of event interaction. Since VACTIV is seemingly the first attempt of applying the newest programming languages and styles to systems of spectrum analysis, the goal of its creation was both getting a convenient and efficient technique for data processing, their methods and events. Now the program is widely used for the processing of gamma-ray spectra in experiments on activation analysis

  13. The vectorization of a ray tracing program for image generation

    Science.gov (United States)

    Plunkett, D. J.; Cychosz, J. M.; Bailey, M. J.

    1984-01-01

    Ray tracing is a widely used method for producing realistic computer generated images. Ray tracing involves firing an imaginary ray from a view point, through a point on an image plane, into a three dimensional scene. The intersections of the ray with the objects in the scene determines what is visible at the point on the image plane. This process must be repeated many times, once for each point (commonly called a pixel) in the image plane. A typical image contains more than a million pixels making this process computationally expensive. A traditional ray tracing program processes one ray at a time. In such a serial approach, as much as ninety percent of the execution time is spent computing the intersection of a ray with the surface in the scene. With the CYBER 205, many rays can be intersected with all the bodies im the scene with a single series of vector operations. Vectorization of this intersection process results in large decreases in computation time. The CADLAB's interest in ray tracing stems from the need to produce realistic images of mechanical parts. A high quality image of a part during the design process can increase the productivity of the designer by helping him visualize the results of his work. To be useful in the design process, these images must be produced in a reasonable amount of time. This discussion will explain how the ray tracing process was vectorized and gives examples of the images obtained.

  14. In-situ thermal testing program strategy

    International Nuclear Information System (INIS)

    1995-06-01

    In the past year the Yucca Mountain Site Characterization Project has implemented a new Program Approach to the licensing process. The Program Approach suggests a step-wise approach to licensing in which the early phases will require less site information than previously planned and necessitate a lesser degree of confidence in the longer-term performance of the repository. Under the Program Approach, the thermal test program is divided into two principal phases: (1) short-term in situ tests (in the 1996 to 2000 time period) and laboratory thermal tests to obtain preclosure information, parameters, and data along with bounding information for postclosure performance; and (2) longer-term in situ tests to obtain additional data regarding postclosure performance. This effort necessitates a rethinking of the testing program because the amount of information needed for the initial licensing phase is less than previously planned. This document proposes a revised and consolidated in situ thermal test program (including supporting laboratory tests) that is structured to meet the needs of the Program Approach. A customer-supplier model is used to define the Project data needs. These data needs, along with other requirements, were then used to define a set of conceptual experiments that will provide the required data within the constraints of the Program Approach schedule. The conceptual thermal tests presented in this document represent a consolidation and update of previously defined tests that should result in a more efficient use of Project resources. This document focuses on defining the requirements and tests needed to satisfy the goal of a successful license application in 2001, should the site be found suitable

  15. SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes

    International Nuclear Information System (INIS)

    Poludniowski, G; Evans, P M; Landry, G; DeBlois, F; Verhaegen, F

    2009-01-01

    A software program, SpekCalc, is presented for the calculation of x-ray spectra from tungsten anode x-ray tubes. SpekCalc was designed primarily for use in a medical physics context, for both research and education purposes, but may also be of interest to those working with x-ray tubes in industry. Noteworthy is the particularly wide range of tube potentials (40-300 kVp) and anode angles (recommended: 6-30 deg.) that can be modelled: the program is therefore potentially of use to those working in superficial/orthovoltage radiotherapy, as well as diagnostic radiology. The utility is free to download and is based on a deterministic model of x-ray spectrum generation (Poludniowski 2007 Med. Phys. 34 2175). Filtration can be applied for seven materials (air, water, Be, Al, Cu, Sn and W). In this note SpekCalc is described and illustrative examples are shown. Predictions are compared to those of a state-of-the-art Monte Carlo code (BEAMnrc) and, where possible, to an alternative, widely-used, spectrum calculation program (IPEM78). (note)

  16. Bureau of radiological health compliance testing procedures for cabinet S-ray systems

    International Nuclear Information System (INIS)

    Miller, E.A.; Sprau, D.

    1976-01-01

    A manual has been developed by the Bureau of Radiological Health of the Food and Drug Administration to establish procedures for the routine field testing of cabinet x-ray systems to determine compliance with the Federal Performance Standard for Cabinet X-Ray Systems, 21 CFR 1020.40. The manual provides specific instructions for testing each model of cabinet x-ray system. Results from the inspection are recorded on a data from which is designed to permit automatic data processing

  17. Field testing for cosmic ray soft errors in semiconductor memories

    International Nuclear Information System (INIS)

    O'Gorman, T.J.; Ross, J.M.; Taber, A.H.; Ziegler, J.F.; Muhlfeld, H.P.; Montrose, C.J.; Curtis, H.W.; Walsh, J.L.

    1996-01-01

    This paper presents a review of experiments performed by IBM to investigate the causes of soft errors in semiconductor memory chips under field test conditions. The effects of alpha-particles and cosmic rays are separated by comparing multiple measurements of the soft-error rate (SER) of samples of memory chips deep underground and at various altitudes above the earth. The results of case studies on four different memory chips show that cosmic rays are an important source of the ionizing radiation that causes soft errors. The results of field testing are used to confirm the accuracy of the modeling and the accelerated testing of chips

  18. A distribution-free test for anomalous gamma-ray spectra

    International Nuclear Information System (INIS)

    Chan, Kung-sik; Li, Jinzheng; Eichinger, William; Bai, Er-Wei

    2014-01-01

    Gamma-ray spectra are increasingly acquired in monitoring cross-border traffic, or in an area search for lost or orphan special nuclear material (SNM). The signal in such data is generally weak, resulting in poorly resolved spectra, thereby making it hard to detect the presence of SNM. We develop a new test for detecting anomalous spectra by characterizing the complete shape change in a spectrum from background radiation; the proposed method may serve as a tripwire for routine screening for SNM. We show that, with increasing detection time, the limiting distribution of the test is given by some functional of the Brownian bridge. The efficacy of the proposed method is illustrated by simulations. - Highlights: • We develop a new non-parametric test for detecting anomalous gamma-ray spectra. • The proposed test has good empirical power for detecting weak signals. • It can serve as an effective tripwire for invoking more thorough scrutiny of the source

  19. Description of CORSET: a computer program for quantitative x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Stohl, F.V.

    1980-08-01

    Quantitative x-ray fluorescence analysis requires a method of correcting for absorption and secondary fluorescence effects due to the sample matrix. The computer program CORSET carries out these corrections without requiring a knowledge of the spectral distribution of the x-ray source, and only requires one standard per element or one standard containing all the elements. Sandia's version of CORSET has been divided into three separate programs to fit Sandia's specific requirements for on-line analysis in a melt facility. The melt facility is used to fabricate new alloys with very variable compositions and requires very rapid analyses during a run. Therefore, the standards must be analyzed several days in advance. Program DAT1 is used to set up a permanent file consisting of all the data related to the standards. Program UNINT is used to set up a permanent file with the intensities, background counts and counting times of the unknowns. Program CORSET uses the files created in UNINT and DAT1 to carry out the analysis. This report contains descriptions, listings, and sample runs for these programs. The accuracy of the analyses carried out with these three programs is about 1 to 2% relative with an elemental concentration of about 10 wt %

  20. An MS-DOS-based program for analyzing plutonium gamma-ray spectra

    International Nuclear Information System (INIS)

    Ruhter, W.D.; Buckley, W.M.

    1989-01-01

    A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: a data-transfer application for transferring spectral data from a CICERO multichannel analyzer to a binary data file, a data-analysis application to analyze plutonium gamma-ray spectra, for plutonium isotopic ratios and weight percents of total plutonium, and a data-quality assurance application to check spectral data for proper data-acquisition setup and performance. Volume 3 contains the software listings for these applications

  1. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  2. Seed viability of five wild Saudi Arabian species by germination and X-ray tests.

    Science.gov (United States)

    Al-Hammad, B A; Al-Ammari, B S

    2017-09-01

    Our objective was to evaluate the usefulness of the germination vs. the X-ray test in determining the initial viability of seeds of five wild species ( Moringa peregrina , Abrus precatorius , Arthrocnemum macrostachyum , Acacia ehrenbergiana and Acacia tortilis ) from Saudi Arabia. Usually several days were required to determine the viability of all five species via germination tests. However, X-ray test will give immediate results on filled/viable seeds. Seeds of all species, except Acacia ehrenbergiana and Acacia tortilis showed high viability in both germination (96-72% at 25/15 °C, 94-70% at 35/25 °C) and X-ray (100-80%) test. Furthermore, there was a general agreement between the germination (19%, 14% at 25/15 °C and 17% and 12% at 35/25 °C) and X-ray (8%, 4%) tests in which seed viability of Acacia ehrenbergiana and Acacia tortilis was very low due to insect damaged embryo as shown in X-ray analysis. Seeds of Abruspreca torius have physical dormancy, which was broken by scarification in concentrated sulfuric acid (10 min), and they exhibited high viability in both the germination (83% at 25/15 °C and 81% at 35/25 °C) and X-ray (96%) tests. Most of the nongerminated seeds of the five species except those of Acacia ehrenbergiana and Acacia tortilis , were alive as judged by the tetrazolium test (TZ). Thus, for the five species examined, the X-ray test was proved to be a good and rapid predictor of seed viability.

  3. Digital computed radiography in industrial X-ray testing

    International Nuclear Information System (INIS)

    Osterloh, K.; Onel, Y.; Zscherpel, U.; Ewert, U.

    2001-01-01

    Computed radiography is used for X-ray testing in many industrial applications. There are different systems depending on the application, e.g. fast systems for detection of material inhomogeneities and slower systems with higher local resolution for detection of cracks and fine details, e.g. in highly stressed areas or in welded seams. The method is more dynamic than film methods, and digital image processing is possible during testing [de

  4. Accelerated leach test development program

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Pietrzak, R.F.; Heiser, J.; Franz, E.M.; Colombo, P.

    1990-11-01

    In FY 1989, a draft accelerated leach test for solidified waste was written. Combined test conditions that accelerate leaching were validated through experimental and modeling efforts. A computer program was developed that calculates test results and models leaching mechanisms. This program allows the user to determine if diffusion controls leaching and, if this is the case, to make projections of releases. Leaching mechanisms other than diffusion (diffusion plus source term partitioning and solubility limited leaching) are included in the program is indicators of other processes that may control leaching. Leach test data are presented and modeling results are discussed for laboratory scale waste forms composed of portland cement containing sodium sulfate salt, portland cement containing incinerator ash, and vinyl ester-styrene containing sodium sulfate. 16 refs., 38 figs., 5 tabs

  5. Materials testing by computerized tomography with neutrons and gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    El-Ghobary, A M; Bakkoush, F A; Megahid, R M [Reactor and Neutron Physics Department, Nuclear Research Center, A.E.A., Cairo (Egypt)

    1997-12-31

    The method of computerized tomography by fast neutrons and gamma-rays are used for inspecting and testing of materials by non-destructive technique. The transmission technique was applied using narrow collimated beams of reactor neutrons and gamma-ray. The neutron and gamma-rays transmitted through the object inspection were measured by means of a neutron gamma detector with Ne - 213 liquid organic scintillator. The undesired pulses of neutrons or gamma-rays are rejected from the transmitted beam by a discrimination technique based on the difference in the decay part of light pulse produced by recoil electrons or recoil protons. The transmitted neutrons or gamma-rays for different projections used to get the image of the section through the object investigated using the method of filtered back projection (FBP) algorithm. 8 figs.

  6. Interferometric and optical tests of water window imaging x ray microscopes

    Science.gov (United States)

    Johnson, R. Barry

    1993-01-01

    Interferometric tests of Schwarzchild X-ray Microscope are performed to evaluate the optical properties and alignment of the components. Photographic measurements of the spatial resolution, focal properties, and vignetting characteristics of the prototype Water Window Imaging X-ray Microscope are made and analyzed.

  7. Seed viability of five wild Saudi Arabian species by germination and X-ray tests

    Directory of Open Access Journals (Sweden)

    B.A. Al-Hammad

    2017-09-01

    Full Text Available Our objective was to evaluate the usefulness of the germination vs. the X-ray test in determining the initial viability of seeds of five wild species (Moringa peregrina, Abrus precatorius, Arthrocnemum macrostachyum, Acacia ehrenbergiana and Acacia tortilis from Saudi Arabia. Usually several days were required to determine the viability of all five species via germination tests. However, X-ray test will give immediate results on filled/viable seeds. Seeds of all species, except Acacia ehrenbergiana and Acacia tortilis showed high viability in both germination (96–72% at 25/15 °C, 94–70% at 35/25 °C and X-ray (100–80% test. Furthermore, there was a general agreement between the germination (19%, 14% at 25/15 °C and 17% and 12% at 35/25 °C and X-ray (8%, 4% tests in which seed viability of Acacia ehrenbergiana and Acacia tortilis was very low due to insect damaged embryo as shown in X-ray analysis. Seeds of Abruspreca torius have physical dormancy, which was broken by scarification in concentrated sulfuric acid (10 min, and they exhibited high viability in both the germination (83% at 25/15 °C and 81% at 35/25 °C and X-ray (96% tests. Most of the nongerminated seeds of the five species except those of Acacia ehrenbergiana and Acacia tortilis, were alive as judged by the tetrazolium test (TZ. Thus, for the five species examined, the X-ray test was proved to be a good and rapid predictor of seed viability.

  8. An MS-DOS-based program for analyzing plutonium gamma-ray spectra

    International Nuclear Information System (INIS)

    Ruhter, W.D.; Buckley, W.M.

    1989-01-01

    A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: (1) a data-transfer application for transferring spectral data from a CICERO multichannel analyzer to a binary data file, (2) a data-analysis application to analyze plutonium gamma-ray spectra for plutonium isotopic ratios and weight percents of total plutonium, (3) and a data-quality assurance application to check spectral data for proper data-acquisition setup and performance. Volume 2 describes the operations of these applications and the installation and maintenance of the software

  9. Testing FlexRay ECUs with a hardware-in-the-loop simulator; Test von FlexRay-Steuergeraeten am Hardware-in-the-Loop Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Stroop, J.; Koehl, S. [dSPACE GmbH, Paderborn (Germany); Peller, M.; Riedesser, P. [BMW AG, Muenchen (Germany)

    2005-07-01

    To master the data communication of complex and safety relevant systems within future vehicles, the BMW Group prepares the application of FlexRay. The accompanying development process plays an important role for the quality, stability and reliability of those systems. Hardware-in-the-loop simulation and test stands are indispensable constituents and they are an integral part of the validation process. The following contribution describes the technology that is used within the BMW Group in more detail, especially in terms of communication networks with FlexRay. (orig.)

  10. Analysis of the X-ray microbeam test result of the flash memories

    International Nuclear Information System (INIS)

    Yan Yihua; Ding Lili; Chen Wei; Guo Hongxia; Guo Xiaoqiang; Lin Dongsheng; Zhang Keying; Zhang Fengqi; Deng Yuliang; Fan Ruyu

    2013-01-01

    Background: The failure phenomenon is difficult to analyze for the flash memories when the whole chip is exposed to irradiation since both the memory array and the peripheral circuits might be degraded. Purpose: In order to detect the radiation susceptibility and corresponding phenomenon of the related circuits that included in the flash memories, the X-ray microbeam is used as the radiation source instead of 60 Co. Methods: The failure phenomenon is studied respectively when the memory array, decoder circuits, the charge pump circuits as well as the I/O circuits are exposed to radiation. The errors are mapped according to the logical address and the failure mechanism is analyzed based on the circuits. Results: Irradiated on the memory .array win lead to regularly distributed 0→1 bit flips, while only 1→0 are found when the row decoder is under exposure. Degradation of the charge pump circuits would lead to the erase/program functional failure. Conclusions: The results suggest that the X-ray microbeam radiation test is a good method for detecting the radiation susceptibility of the integrated circuits that contains lots of circuit modules. (authors)

  11. Prototype steam generator test at SCTI/ETEC. Acoustic program test plan

    International Nuclear Information System (INIS)

    Greene, D.A.; Thiele, A.; Claytor, T.N.

    1981-10-01

    This document is an integrated test plan covering programs at General Electric (ARSD), Rockwell International (RI) and Argonne National Laboratory (CT). It provides an overview of the acoustic leak detection test program which will be completed in conjunction with the prototype LMFBR steam generator at the Energy Technology Engineering Laboratory. The steam generator is installed in the Sodium Components Test Installation (SCTI). Two acoustic detection systems will be used during the test program, a low frequency system developed by GE-ARSD (GAAD system) and a high frequency system developed by RI-AI (HALD system). These systems will be used to acquire data on background noise during the thermal-hydraulic test program. Injection devices were installed during fabrication of the prototype steam generator to provide localized noise sources in the active region of the tube bundle. These injectors will be operated during the steam generator test program, and it will be shown that they are detected by the acoustic systems

  12. Computer program for diagnostic X-ray exposure conversion

    International Nuclear Information System (INIS)

    Lewis, S.L.

    1984-01-01

    Presented is a computer program designed to convert any given set of diagnostic X-ray exposure factors sequentially into another, yielding either an equivalent photographic density or one increased or decreased by a specifiable proportion. In addition to containing the wherewithal with which to manipulate a set of exposure factors, the facility to print hard (paper) copy is included enabling the results to be pasted into a notebook and used at any time. This program was originally written as an investigative exercise into examining the potential use of computers for practical radiographic purposes as conventionally encountered. At the same time, its possible use as an educational tool was borne in mind. To these ends, the current version of this program may be used as a means whereby exposure factors used in a diagnostic department may be altered to suit a particular requirement or may be used in the school as a mathematical model to describe the behaviour of exposure factors under manipulation without patient exposure. (author)

  13. High gamma-rays irradiation tests of critical components for ITER (International Thermonuclear Experimental Reactor) in-vessel remote handling system

    International Nuclear Information System (INIS)

    Obara, Kenjiro; Kakudate, Satoshi; Oka, Kiyoshi

    1999-02-01

    In ITER, the in-vessel remote handling is inevitably required to assemble and maintain the activated in-vessel components due to deuterium and tritium operation. Since the in-vessel remote handling system has to be operated under the intense of gamma ray irradiation, the components of the remote handling system are required to have radiation hardness so as to allow maintenance operation for a sufficient length of time under the ITER in-vessel environments. For this, the Japan, European and Russian Home Teams have extensively conducted gamma ray irradiation tests and quality improvements including optimization of material composition through ITER R and D program in order to develop radiation hard components which satisfy the doses from 10 MGy to 100 MGy at a dose rate of 1 x 10 6 R/h (ITER R and D Task: T252). This report describes the latest status of radiation hard component development which has been conducted by the Japan Home Team in the ITER R and D program. The number of remote handling components tested is about seventy and these are categorized into robotics (Subtask 1), viewing system (Subtask 2) and common components (Subtask 3). The irradiation tests, including commercial base products for screening, modified products and newly developed products to improve the radiation hardness, were carried out using the gamma ray irradiation cells in Takasaki Establishment, JAERI. As a result, the development of the radiation hard components which can be tolerable for high temperature and gamma radiation has been well progressed, and many components, such as AC servo motor with ceramics insulated wire, optical periscope and CCD camera, have been newly developed. (author)

  14. High gamma-rays irradiation tests of critical components for ITER (International Thermonuclear Experimental Reactor) in-vessel remote handling system

    Energy Technology Data Exchange (ETDEWEB)

    Obara, Kenjiro; Kakudate, Satoshi; Oka, Kiyoshi [Department of Fusion Engineering Research, Naka Fusion Research Establishment, Japan Atomic Energy Research Institute, Naka, Ibaraki (Japan)] [and others

    1999-02-01

    In ITER, the in-vessel remote handling is inevitably required to assemble and maintain the activated in-vessel components due to deuterium and tritium operation. Since the in-vessel remote handling system has to be operated under the intense of gamma ray irradiation, the components of the remote handling system are required to have radiation hardness so as to allow maintenance operation for a sufficient length of time under the ITER in-vessel environments. For this, the Japan, European and Russian Home Teams have extensively conducted gamma ray irradiation tests and quality improvements including optimization of material composition through ITER R and D program in order to develop radiation hard components which satisfy the doses from 10 MGy to 100 MGy at a dose rate of 1 x 10{sup 6} R/h (ITER R and D Task: T252). This report describes the latest status of radiation hard component development which has been conducted by the Japan Home Team in the ITER R and D program. The number of remote handling components tested is about seventy and these are categorized into robotics (Subtask 1), viewing system (Subtask 2) and common components (Subtask 3). The irradiation tests, including commercial base products for screening, modified products and newly developed products to improve the radiation hardness, were carried out using the gamma ray irradiation cells in Takasaki Establishment, JAERI. As a result, the development of the radiation hard components which can be tolerable for high temperature and gamma radiation has been well progressed, and many components, such as AC servo motor with ceramics insulated wire, optical periscope and CCD camera, have been newly developed. (author)

  15. Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums

    International Nuclear Information System (INIS)

    Park, Jong Kil; Maeng, Seong Jun; Lee, Yeon Ee; Hwang, Tae Won

    2008-01-01

    The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: the proper X-ray energy is under 3 MeV to test the drums of 320 β and less; both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  16. ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, R A; Anderson, S G; Barty, C P; Chu, T S; Ebbers, C A; Gibson, D J; Hartemann, F V; Adolphsen, C; Jongewaard, E N; Raubenheimer, T; Tantawi, S G; Vlieks, A E; Wang, J W

    2010-05-12

    In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

  17. Testing of X-ray radiometric enrichnment of polymetallic ores

    International Nuclear Information System (INIS)

    Eliseev, N.I.; Panova, N.I.; Kirbitova, N.V.; Shramm, E.O.; Efremov, Yu.G.

    1987-01-01

    Testing of X-ray radiometric method of sorting of polymetallic ores using the developed X-ray radiometric device was conducted. It was shown that introduction of preliminary concentration at the factory made the method of fragment separation to be the perspective one, enabling to elevate the factory production with respect to commercial ore and reduce the cost of ore processing. In the case of preliminary concentration, conducted at the mine, it is advisable to perform ore sorting in the flow formed to monolayer

  18. Design, Construction, and Testing of Lightweight X-ray Mirror Modules

    Science.gov (United States)

    McClelland, Ryan S.; Biskach, Michael P.; Chan, Kai-Wing; Espina, Rebecca A.; Hohl, Bruce R.; Matson, Elizabeth A.; Saha, Timo C.; Zhang, William W.

    2013-01-01

    Lightweight and high resolution optics are needed for future space-based X-ray telescopes to achieve advances in high-energy astrophysics. The Next Generation X-ray Optics (NGXO) team at NASA GSFC is nearing mission readiness for a 10 arc-second Half Power Diameter (HPD) slumped glass mirror technology while laying the groundwork for a future 1-2 arc-second technology based on polished silicon mirrors. Technology Development Modules (TDMs) have been designed, fabricated, integrated with mirrors segments, and extensively tested to demonstrate technology readiness. Tests include X-ray performance, thermal vacuum, acoustic load, and random vibration. The thermal vacuum and acoustic load environments have proven relatively benign, while the random vibration environment has proven challenging due to large input amplification at frequencies above 500 Hz. Epoxy selection, surface preparation, and larger bond area have increased bond strength while vibration isolation has decreased vibration amplification allowing for space launch requirements to be met in the near term. The next generation of TDMs, which demonstrates a lightweight structure supporting more mirror segments, is currently being fabricated. Analysis predicts superior performance characteristics due to the use of E-60 Beryllium-Oxide Metal Matrix Composite material, with only a modest cost increase. These TDMs will be larger, lighter, stiffer, and stronger than the current generation. Preliminary steps are being taken to enable mounting and testing of 1-2 arc-second mirror segments expected to be available in the future. A Vertical X-ray Test Facility (VXTF) will minimize module gravity distortion and allow for less constrained mirror mounts, such as fully kinematic mounts. Permanent kinematic mounting into a modified TDM has been demonstrated to achieve 2 arc-second level distortion free alignment.

  19. Towards a Theory for Testing Non-terminating Programs

    DEFF Research Database (Denmark)

    Gotlieb, Arnaud; Petit, Matthieu

    2009-01-01

    Non-terminating programs are programs that legally perform unbounded computations. Though they are ubiquitous in real-world applications, testing these programs requires new theoretic developments as usual definitions of test data adequacy criteria ignore infinite paths. This paper develops...... a theory of program-based structural testing based on operational semantics. Reasoning at the program semantics level permits to cope with infinite paths (and non-feasible paths) when defining test data adequacy criteria. As a result, our criteria respect the first Weyuker’s property on finite...... applicability, even for non-terminating programs. We discuss the consequences of this re-interpretation of test data adequacy criteria w.r.t. existing test coverage criteria....

  20. Using Virtual ATE Model to Migrate Test Programs

    Institute of Scientific and Technical Information of China (English)

    王晓明; 杨乔林

    1995-01-01

    Bacause of high development costs of IC (Integrated Circuit)test programs,recycling existing test programs from one kind of ATE (Automatic Test Equipment) to another or generating directly from CAD simulation modules to ATE is more and more valuable.In this paper,a new approach to migrating test programs is presented.A virtual ATE model based on object-oriented paradigm is developed;it runs Test C++ (an intermediate test control language) programs and TeIF(Test Inftermediate Format-an intermediate pattern),migrates test programs among three kinds of ATE (Ando DIC8032,Schlumberger S15 and GenRad 1732) and generates test patterns from two kinds of CAD 9Daisy and Panda) automatically.

  1. 47 CFR 73.713 - Program tests.

    Science.gov (United States)

    2010-10-01

    ... International Broadcast Stations § 73.713 Program tests. (a) Upon completion of construction of an international.... The Commission reserves the right to change the date of the beginning of such tests or to suspend or revoke the authority for program tests as and when such action may appear to be in the public interest...

  2. X ray reflection masks: Manufacturing, characterization and first tests

    Science.gov (United States)

    Rahn, Stephen

    1992-09-01

    SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  3. Nevada Test Site closure program

    International Nuclear Information System (INIS)

    Shenk, D.P.

    1994-08-01

    This report is a summary of the history, design and development, procurement, fabrication, installation and operation of the closures used as containment devices on underground nuclear tests at the Nevada Test Site. It also addresses the closure program mothball and start-up procedures. The Closure Program Document Index and equipment inventories, included as appendices, serve as location directories for future document reference and equipment use

  4. Computer programs for data reduction and interpretation in plutonium and uranium analysis by gamma ray spectrometry

    International Nuclear Information System (INIS)

    Singh, R.K.; Moorthy, A.D.; Babbar, R.K.; Udagatti, S.V.

    1989-01-01

    Non destructive gamma ray have been developed for analysis of isotopic abundances and concentrations of plutonium and uranium in the respective product solutions of a reprocessing plant. The method involves analysis of gamma rays emitted from the sample and uses a multichannel analyser system. Data reduction and interpretation of these techniques are tedious and time consuming. In order to make it possible to use them in routine analysis, computer programs have been developed in HP-BASIC language which can be used in HP-9845B desktop computer. A set of programs, for plutonium estimation by high resolution gamma ray spectrometry and for on-line measurement of uranium by gamma ray spectrometry are described in this report. (author) 4 refs., 3 tabs., 6 figs

  5. RayTrace: A Simplified Ray Tracing Software for use in AutoCad

    DEFF Research Database (Denmark)

    Reimann, Gregers Peter; Tang, C.K.

    2005-01-01

    A design aid tool for testing and development of daylighting systems was developed. A simplified ray tracing software was programmed in Lisp for AutoCad. Only fully specularly reflective, fully transparent and fully absorbant surfaces can be defined in the software. The software is therefore best...

  6. Tests of lobster eye optics for small space X-ray telescope

    International Nuclear Information System (INIS)

    Tichy, Vladimir; Barbera, Marco; Collura, Alfonso; Hromcik, Martin; Hudec, Rene; Inneman, Adolf; Jakubek, Jan; Marsik, Jiri; Marsikova, Veronika; Pina, Ladislav; Varisco, Salvatore

    2011-01-01

    The Lobster eye design for a grazing incidence X-ray optics provides wide field of view of the order of many degrees, for this reason it can be a convenient approach for the construction of space all-sky X-ray monitors. We present preliminary results of tests of prototype lobster eye X-ray optics in quasi parallel beam full imaging mode conducted using the 35 m long X-ray beam-line of INAF-OAPA in Palermo (Italy). X-ray images at the focal plane have been taken with a microchannel plate (MCP) detector at several energy values from 0.3 to 8 keV. The gain, the field of view and the angular resolution have been measured and compared with theoretical values.

  7. Recommended well drilling and testing program

    International Nuclear Information System (INIS)

    Long, J.; Wilson, C.

    1978-07-01

    A well drilling and testing program is recommended by Lawrence Berkeley Laboratory to identify the hydrology of deep basalts in the Pasco Basin. The ultimate objective of this program is to assist in determining the feasibility of locating a nuclear waste repository on the Hanford Reservation. The recommended program has been staged for maximum effectiveness. In the first stage, six wells have been identified for drilling and testing which, when coupled with existing wells, will provide sufficient data for a preliminary overview of basin hydrology and a preliminary determination of the hydrologic suitability of the deep basalt for a repository site. The rate at which the first stage wells are drilled and tested will depend upon the date at which a preliminary determination of site suitability is required. It was assumed that a preliminary determination of suitability would be required in 1980, in which case all six first stage wells would be drilled in FY 1979. If the results of the first stage analysis are favorable for repository siting, tentative repository sites can be identified and a second stage hydrology program can be implemented to provide the necessary details of the flow system. To accomplish this stage, a number of deep wells would be required at locations both inside and outside the basin, with specific sites to be identified as the work progresses to obtain maximum utility of existing data. A program is recommended for testing in each new well and for completion of testing in each existing well. Recommended tests include borehole geophysics, pressure and permeability testing, geochemical sampling, tracer testing, hydrofracturing and borehole fracture logging. The entire data collection program is oriented toward providing the information required to establish and verify an accurate numerical model of the Pasco Basin

  8. Manipulator comparative testing program

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Sundstrom, E.; Herndon, J.N.; Fujita, Y.; Maeda, M.

    1986-01-01

    The Manipulator Comparative Testing Program examined differences among manipulator systems from the United States and Japan. The manipulator systems included the Meidensha BILARM 83A, the Model M-2 of Central Research Laboratories Division of Sargent Industries (CRL), and the GCA Corporation PaR Systems Model 6000. The site of testing was the Remote Operations Maintenance Demonstration (ROMD) facility, operated by the Fuel Recycle Division in the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL). In all stages of testing, operators using the CRL Model M-2 manipulator had consistently lower times to completion and error rates than they did using other machines. Performance was second best with the Meidensha BILARM 83A in master-slave mode. Performance with the BILARM in switchbox mode and the PaR 6000 manipulator was approximately equivalent in terms of criteria recorded in testing. These data show no impact of force reflection on task performance

  9. Development of improved x-ray optics for analytical x-ray microbeams. CRADA final report for CRADA Number Y-1294-0283

    International Nuclear Information System (INIS)

    Carpenter, D.A.; Gao, N.; Xiao, Q.F.; Ponomarev, I.

    1996-01-01

    The purpose of this CRADA was to develop improved glass capillary, x-ray optics for analytical x-ray microbeam applications. X-Ray Optical Systems, Inc. (XOS) designed and fabricated capillary optics and LMES tested those optics for x-ray microanalytical applications using its unique X-Ray Microprobe. Tapered capillaries with 3-microm and 8-microm output openings were fabricated and tested. The tapered capillaries had better spectral quality for x-ray microfluorescence (XRMF) analysis, than non-tapered, straight capillaries that are currently used in the system. X-ray beam count-rates for the tapered capillaries were also greater than the straight capillaries. Two monolithic, polycapillary optics were fabricated and tested. The polycapillary optics produced focal spots of 40 and 100 microm. Beam intensities for the polycapillaries were, respective, 44 and 18 times the intensities found in straight 50-microm and 100-microm capillaries. High-sensitivity scanning will be possible because of the enhanced intensity of the polycapillary optic. LMES and the DP program will benefit from improved capabilities for nondestructive x-ray microanalysis, while XOS will benefit from test results that will enhance the marketability of their products

  10. Periodical test program in depth revision

    International Nuclear Information System (INIS)

    Feltin, C.; Zermizoglou, R.

    1987-11-01

    Inspection visits made to different sites during 1980 and 1981 evidenced the need to extend and define more precisely the periodical tests performed on safety related systems; thus Electricite de France was requested by the Safety Authorities to re-examine the periodical test program for all safety related systems. This paper presents the methodology adopted by Electricite de France in order to perform an exhaustive analysis of the periodical test program for the 900 and 1300 MWe plants, and the organization set up at the IPSN at one hand and Electricite de France on the other hand for the purpose of elaborating a periodical test program which would be ratified by the Safety Authorities

  11. Gamma-Ray, Cosmic Ray and Neutrino Tests of Lorentz Invariance and Quantum Gravity Models

    Science.gov (United States)

    Stecker, Floyd

    2011-01-01

    High-energy astrophysics observations provide the best possibilities to detect a very small violation of Lorentz invariance such as may be related to the structure of space-time near the Planck scale of approximately 10(exp -35) m. I will discuss here the possible signatures of Lorentz invariance violation (LIV) from observations of the spectra, polarization, and timing of gamma-rays from active galactic nuclei and gamma-ray bursts. Other sensitive tests are provided by observations of the spectra of ultrahigh energy cosmic rays and neutrinos. Using the latest data from the Pierre Auger Observatory one can already derive an upper limit of 4.5 x 10(exp -23) to the amount of LIV of at a proton Lorentz factor of approximately 2 x 10(exp 11). This result has fundamental implications for quantum gravity models. I will also discuss the possibilities of using more sensitive space based detection techniques to improve searches for LIV in the future.

  12. X-ray mirror development and testing for the ATHENA mission

    Science.gov (United States)

    Della Monica Ferreira, Desiree; Jakobsen, Anders C.; Massahi, Sonny; Christensen, Finn E.; Shortt, Brian; Garnæs, Jørgen; Torras-Rosell, Antoni; Krumrey, Michael; Cibik, Levent; Marggraf, Stefanie

    2016-07-01

    This study reports development and testing of coatings on silicon pore optics (SPO) substrates including pre and post coating characterisation of the x-ray mirrors using Atomic Force Microscopy (AFM) and X-ray reflectometry (XRR) performed at the 8 keV X-ray facility at DTU Space and with synchrotron radiation in the laboratory of PTB at BESSY II. We report our findings on surface roughness and coating reflectivity of Ir/B4C coatings considering the grazing incidence angles and energies of ATHENA and long term stability of Ir/B4C, Pt/B4C, W/Si and W/B4C coatings.

  13. SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

    Science.gov (United States)

    Winternitz, Luke; Mitchell, Jason W.; Hassouneh, Munther A.; Valdez, Jennifer E.; Price, Samuel R.; Semper, Sean R.; Yu, Wayne H.; Ray, Paul S.; Wood, Kent S.; Arzoumanian, Zaven; hide

    2016-01-01

    The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the high-fidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars

  14. The PUMA test program and data analysis

    International Nuclear Information System (INIS)

    Han, J.T.; Morrison, D.L.

    1997-01-01

    The PUMA test program is sponsored by the U.S. Nuclear Regulatory Commission to provide data that are relevant to various Boiling Water Reactor phenomena. The author briefly describes the PUMA test program and facility, presents the objective of the program, provides data analysis for a large-break loss-of-coolant accident test, and compares the data with a RELAP5/MOD 3.1.2 calculation

  15. Requirements for use of nonmedical x-ray generators at SLAC

    International Nuclear Information System (INIS)

    Busick, D.D.

    1984-09-01

    The risks associated with use of x-ray equipment have long been recognized. While the relative frequency of x-ray damage is small, machine produced x-rays and large radiography sources continue to account for a large percentage of preventable radiation injuries reported worldwide. The intent of this report is to formalize SLAC's radiation safety program as it applies to radiation producing equipment (diffraction, fluorescence analysis and nondestructive testing). It does not apply to the two-mile linac, experimental areas or other x-ray producing equipment directly related to the high energy physics program. 4 refs., 3 figs., 1 tab

  16. Design and Tests of the Hard X-ray Polarimeter X-Calibur

    Directory of Open Access Journals (Sweden)

    M. Beilicke

    2014-12-01

    Full Text Available X-ray polarimetry promises to give qualitatively new information bout high-energy astrophysical sources, such as binary black hole  systems, micro-quasars, active galactic nuclei, and gamma-ray bursts. We designed, built and tested ahard X-ray polarimeter, X-Calibur, to be used in the focal plane of the InFOCuS grazing incidence hard X-ray telescope.X-Calibur combines a low-Z Compton scatterer with a CZT detector assembly to measure the polarization of 20−60 keV X-rays making use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation; in principal, a similar space-borne experiment could be operated in the 5−100 keV regime. X-Calibur achieves a high detection efficiency of order unity.

  17. A set of X-ray test objects for quality control in television fluoroscopy

    International Nuclear Information System (INIS)

    Hay, G.A.; Clarke, O.F.; Coleman, N.J.; Cowen, A.R.

    1985-01-01

    The history of performance testing in Leeds of television fluoroscopic systems is briefly outlined. Using the visual, physical and technological requirements as a basis, a set of nine test objects for quality control in television fluoroscopy is described. The factors measured by the test objects are listed in the introduction; the test objects and their function are fully described in the remainder of the paper. The test objects, in conjunction with a television oscilloscope, give both subjective and objective information about the X-ray system. Three of the test objects enable the physicist or engineer to adjust certain aspects of the performance of the X-ray system. The set of nine test objects is available commercially. (author)

  18. Performance test of Spectran-F and Spectran-III computer programs for resolving the 137Cs-110Ag double peak in gamma-ray spectrometric analysis

    International Nuclear Information System (INIS)

    Terada, H.; Malinowski, J.; Blick, H.

    1981-09-01

    The performance of the computer programs (Spectran F and Spectran-III) in resolving the 137 Cs-sup(110m)Ag double peak at 661.6-657.7 keV in the gamma-ray spectrum was investigated. In the experiments, the intensity ratios of both lines in the double peak were varied from 0.1 to 60. The results obtained show, that both programs have almost the same performance in resolving the double peak investigated, with slight superiority of Spectran-F. If accuracy better than 5% is desired, the peak intensity ratio in the dublet must be kept below 10. (orig.)

  19. X-ray beam size measurements on the Advanced Test Accelerator

    International Nuclear Information System (INIS)

    Struve, K.W.; Chambers, F.W.; Lauer, E.J.; Slaughter, D.R.

    1986-01-01

    The electron beam size has been determined on the Advanced Test Accelerator (ATA) by intercepting the beam with a target and measuring the resulting x-ray intensity as a function of time as the target is moved through the beam. Several types of targets have been used. One is a tantalum rod which extends completely across the drift chamber. Another is a tungsten powder filled carbon crucible. Both of these probes are moved from shot to shot so that the x-ray signal intensity varies with probe position. A third is a larger tantalum disk which is inserted on beam axis to allow determining beam size on a one shot basis. The x-ray signals are detected with an MCP photomultiplier tube located at 90 0 to the beamline. It is sufficiently shielded to reject background x-rays and neutrons. The signals were digitized, recorded and later unfolded to produce plots of x-ray intensity versus probe position for several times during the pulse. The presumption that the x-ray intensity is proportional to beam current density is checked computationally. Details of the probe construction and PMT shielding, as well as sample measurements are given

  20. Determination of seed viability of eight wild Saudi Arabian species by germination and X-ray tests.

    Science.gov (United States)

    Al-Turki, Turki A; Baskin, Carol C

    2017-05-01

    Our purpose was to evaluate the usefulness of the germination vs. the X-ray test in determining the initial viability of seeds of eight wild species ( Salvia spinosa , Salvia aegyptiaca , Ochradenus baccatus , Ochradenus arabicus , Suaeda aegyptiaca , Suaeda vermiculata , Prosopisfarcta and Panicumturgidum ) from Saudi Arabia. Several days were required to determine viability of all eight species via germination tests, while immediate results on filled/viable seeds were obtained with the X-ray test. Seeds of all the species, except Sa.aegyptiaca , showed high viability in both the germination (98-70% at 25/15 °C, 93-66% at 35/25 °C) and X-ray (100-75%) test. Furthermore, there was general agreement between the germination (10% at 25/15 °C and 8% at 35/25 °C) and X-ray (5%) tests that seed viability of Sa.aegyptiaca was very low, and X-ray analysis revealed that this was due to poor embryo development. Seeds of P.farcta have physical dormancy, which was broken by scarification in concentrated sulfuric acid (10 min), and they exhibited high viability in both the germination (98% at 25/15 °C and 93% at 35/25 °C) and X-ray (98%) test. Most of the nongerminated seeds of the eight species except those of Sa.aegyptiaca were alive as judged by the tetrazolium test (TZ). Thus, for the eight species examined, the X-ray test was a good and rapid predictor of seed viability.

  1. The Northern regional programme for the acceptance testing of X-ray equipment

    International Nuclear Information System (INIS)

    Faulkner, K.; Harrison, R.M.; Kotre, C.J.; Smith, S.; Davies, M.; Barker, P.

    1989-01-01

    Since 1984 the UK Northern Regional Medical Physics Department has participated in a regional acceptance testing programme for all X-ray equipment from mobile units to computed tomography scanners. Organizational and radiation physics aspects of the programme are described. Three levels of tests are performed by physicists: the first on installation, the second after 3 months, the final visit just prior to the end of the manufacturers warranty. The second test is only performed if any aspect of performance requires rechecking as a result of the first. Acceptance test protocols are based on those published by the Institute of Physical Sciences in Medicine. Details limiting values for the acceptance test measurements are given. In some instances testing has resulted in modifications to the design and construction of X-ray equipment. Acceptance testing is important in determining a baseline standard of performance against which routine quality assurance may be assessed. (author)

  2. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  3. A Unique Outside Neutron and Gamma Ray Instrumentation Development Test Facility at NASA's Goddard Space Flight Center

    Science.gov (United States)

    Bodnarik, J.; Evans, L.; Floyd, S.; Lim, L.; McClanahan, T.; Namkung, M.; Parsons, A.; Schweitzer, J.; Starr, R.; Trombka, J.

    2010-01-01

    An outside neutron and gamma ray instrumentation test facility has been constructed at NASA's Goddard Space Flight Center (GSFC) to evaluate conceptual designs of gamma ray and neutron systems that we intend to propose for future planetary lander and rover missions. We will describe this test facility and its current capabilities for operation of planetary in situ instrumentation, utilizing a l4 MeV pulsed neutron generator as the gamma ray excitation source with gamma ray and neutron detectors, in an open field with the ability to remotely monitor and operate experiments from a safe distance at an on-site building. The advantage of a permanent test facility with the ability to operate a neutron generator outside and the flexibility to modify testing configurations is essential for efficient testing of this type of technology. Until now, there have been no outdoor test facilities for realistically testing neutron and gamma ray instruments planned for solar system exploration

  4. Testing programs for the Multimission Modular Spacecraft

    Science.gov (United States)

    Greenwell, T. J.

    1978-01-01

    The Multimission Modular Spacecraft (MMS) provides a standard spacecraft bus to a user for a variety of space missions ranging from near-earth to synchronous orbits. The present paper describes the philosophy behind the MMS module test program and discusses the implementation of the test program. It is concluded that the MMS module test program provides an effective and comprehensive customer buy-off at the subsystem contractor's plant, is an optimum approach for checkout of the subsystems prior to use for on-orbit servicing in the Shuttle Cargo Bay, and is a cost-effective technique for environmental testing.

  5. The Northern Regional Programme for the acceptance testing of X-ray equipment

    International Nuclear Information System (INIS)

    Faulkner, K.; Harrison, R.M.; Kotre, C.J.; Smith, S.; Davies, M.; Barker, P.

    1989-01-01

    Since 1984 the Regional Medical Physics Department has participated in a regional acceptance testing programme for all X-ray equipment from mobile units to computed tomography scanners. The organizational and radiation physics aspects of the programme are described. Three levels of tests are performed by physicists: the first on installation, the second after 3 months, and the final visit just prior to the end of the manufacturer's warranty. The second test is only performed if any aspect of performance requires rechecking as a result of the first visit. Acceptance test protocols are based on those published by the Institute of Physical Sciences in Medicine. Details of the limiting values for the acceptance test measurements are given. The results of the programme are discussed. In some instances the testing has resulted in modifications to the design and construction of X-ray equipment. Acceptance testing is important in determining a baseline standard of performance against which routine quality assurance may be assessed. (author)

  6. X-ray phase scanning setup for non-destructive testing using Talbot-Lau interferometer

    Science.gov (United States)

    Bachche, S.; Nonoguchi, M.; Kato, K.; Kageyama, M.; Koike, T.; Kuribayashi, M.; Momose, A.

    2016-09-01

    X-ray grating interferometry has a great potential for X-ray phase imaging over conventional X-ray absorption imaging which does not provide significant contrast for weakly absorbing objects and soft biological tissues. X-ray Talbot and Talbot-Lau interferometers which are composed of transmission gratings and measure the differential X-ray phase shifts have gained popularity because they operate with polychromatic beams. In X-ray radiography, especially for nondestructive testing in industrial applications, the feasibility of continuous sample scanning is not yet completely revealed. A scanning setup is frequently advantageous when compared to a direct 2D static image acquisition in terms of field of view, exposure time, illuminating radiation, etc. This paper demonstrates an efficient scanning setup for grating-based Xray phase imaging using laboratory-based X-ray source. An apparatus consisting of an X-ray source that emits X-rays vertically, optical gratings and a photon-counting detector was used with which continuously moving objects across the field of view as that of conveyor belt system can be imaged. The imaging performance of phase scanner was tested by scanning a long continuous moving sample at a speed of 5 mm/s and absorption, differential-phase and visibility images were generated by processing non-uniform moire movie with our specially designed phase measurement algorithm. A brief discussion on the feasibility of phase scanner with scanning setup approach including X-ray phase imaging performance is reported. The successful results suggest a breakthrough for scanning objects those are moving continuously on conveyor belt system non-destructively using the scheme of X-ray phase imaging.

  7. Automated X-ray television complex for testing large dynamic objects

    International Nuclear Information System (INIS)

    Gusev, E.A.; Luk'yanenko, Eh.A.; Chelnokov, V.B.; Kuleshov, V.K.; Alkhimov, Yu.V.

    1992-01-01

    An automated X-ray television complex on the base of matrix gas-dischage large-area (2.1x1.0 m) converter for testing large cargoes and containers, as well as for inductrial article diagnostics is described. The complex pulsed operation with the 512 kbytes television digital memory unit provides for testing dynamic objects under minimal doses (20-100 μR)

  8. Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program

    International Nuclear Information System (INIS)

    2002-01-01

    The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase 'gas generationtesting' shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

  9. Modulating effect of dimethylbenzanthracene on gamma-ray mutagenesis in the soybean test system

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T. [National Inst. of Genetics, Mishima, Shizuoka (Japan); Inoue, T.

    1987-10-15

    Dimethylbenzanthracene (DMBA), a strong tumor initiator, did not show mutagenic activity in the soybean test system either alone or in combination with tumor promoter, TPA. In combination treatments with DMBA and gamma-rays, the mutagenicity of gamma-rays was not affected by post-treatment with DMBA. However, DMBA pre-treatment clearly reduced gammaray-ray induced spotting frequency, suggesting that DMBA affects mutagenesis in gamma-irradiated soybean cells.

  10. Fatigue damage observed non-destructively in fibre composite coupon test specimens by X-ray CT

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2016-01-01

    This study presents a method for monitoring the 3D fatigue damage progression on a micro-structural level in a glass fibre/polymer coupon test specimen by means of laboratory X-ray Computed Tomography (CT). A modified mount and holder made for the standard test samples to fit into the X-ray CT...... scanner along with a tension clamp solution is presented. Initially, the same location of the test specimen is inspected by ex-situ X-ray CT during the fatigue loading history, which shows the damage progression on a micro-structural level. The openings of individual uni-directional (UD) fibre fractures...

  11. Non-destructive test for VHTR fuel using 160kV X-ray system in Hotcell

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jun; Yoo, Boung Ok; Choo, Yong sun; Baik Sang youl; Kim, Hee Moon; Ahn, Sang Bok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The research for VHTR which is one of the next generation reactor has been actively carried out. As a part of the research for VHTR, an irradiation examination for the VHTR fuel was performed to confirm an in-pile behavior in HANARO. The non-destructive test for the irradiated fuel is very important to understand the in-pile behavior of the fuel. Especially, the X-ray system is useful to observe the fuel shape without destruction. A dimensional change and defect of the fuel can be confirmed thorough the Xray system. Also, using the 3-D software and CT technology, the fuel shape can be intuitionally observed. The 450kV and 160kV X-ray system were installed and operated in IMEF hotcell. The 160kV X-ray system relatively using a low voltage is suitable to a small scale sample. And high resolution images can be obtained. In this study, the non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. Through these test, the possibility for the X-ray inspection of irradiated fuel was confirmed. The non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. The clear images of the irradiated coated particle were produced without the radiation damage during the Xray inspection. The X-ray images of the VHTR fuel will be utilized as the in-pile performance validation data.

  12. Non-destructive test for VHTR fuel using 160kV X-ray system in Hotcell

    International Nuclear Information System (INIS)

    Kim, Young Jun; Yoo, Boung Ok; Choo, Yong sun; Baik Sang youl; Kim, Hee Moon; Ahn, Sang Bok

    2016-01-01

    The research for VHTR which is one of the next generation reactor has been actively carried out. As a part of the research for VHTR, an irradiation examination for the VHTR fuel was performed to confirm an in-pile behavior in HANARO. The non-destructive test for the irradiated fuel is very important to understand the in-pile behavior of the fuel. Especially, the X-ray system is useful to observe the fuel shape without destruction. A dimensional change and defect of the fuel can be confirmed thorough the Xray system. Also, using the 3-D software and CT technology, the fuel shape can be intuitionally observed. The 450kV and 160kV X-ray system were installed and operated in IMEF hotcell. The 160kV X-ray system relatively using a low voltage is suitable to a small scale sample. And high resolution images can be obtained. In this study, the non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. Through these test, the possibility for the X-ray inspection of irradiated fuel was confirmed. The non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. The clear images of the irradiated coated particle were produced without the radiation damage during the Xray inspection. The X-ray images of the VHTR fuel will be utilized as the in-pile performance validation data.

  13. Analysis of the KROTOS KFC test by coupling X-Ray image analysis and MC3D calculations

    Energy Technology Data Exchange (ETDEWEB)

    Brayer, C.; Charton, A.; Grishchenko, D.; Fouquart, P.; Bullado, Y.; Compagnon, F.; Correggio, P.; Cassiaut-Louis, N.; Piluso, P. [Commissariat a l' Energie Atomique et Aux Energies Alternatives, CEA Cadarache, DEN, F-13108 Saint-Paul-Les-Durance (France)

    2012-07-01

    During a hypothetical severe accident sequence in a Pressurized Water Reactor (PWR), the hot molten materials (corium) issuing from the degraded reactor core may generate a steam explosion if they come in contact with water and may damage the structures and threaten the reactor integrity. The SERENA program is an international OECD project that aims at helping the understanding of this phenomenon also called Fuel Coolant Interaction (FCI) by providing data. CEA takes part in this program by performing tests in its KROTOS facility where steam explosions using prototypic corium can be triggered. Data about the different phases in the premixing are extracted from the KROTOS X-Ray radioscopy images by using KIWI software (KROTOS Image analysis of Water-corium Interaction) currently developed by CEA. The MC3D code, developed by IRSN, is a thermal-hydraulic multiphase code mainly dedicated to FCI studies. It is composed of two applications: premixing and explosion. An overall FCI calculation with MC3D requires a premixing calculation followed by an explosion calculation. The present paper proposes an alternative approach in which all the features of the premixing are extracted from the X-Ray pictures using the KIWI software and transferred to an MC3D dataset for a direct simulation of the explosion. The main hypothesis are discussed as well as the first explosion results obtained with MC3D for the KROTOS KFC test. These results are rather encouraging and are analyzed on the basis of comparisons with the experimental data. (authors)

  14. Analysis of the KROTOS KFC test by coupling X-Ray image analysis and MC3D calculations

    International Nuclear Information System (INIS)

    Brayer, C.; Charton, A.; Grishchenko, D.; Fouquart, P.; Bullado, Y.; Compagnon, F.; Correggio, P.; Cassiaut-Louis, N.; Piluso, P.

    2012-01-01

    During a hypothetical severe accident sequence in a Pressurized Water Reactor (PWR), the hot molten materials (corium) issuing from the degraded reactor core may generate a steam explosion if they come in contact with water and may damage the structures and threaten the reactor integrity. The SERENA program is an international OECD project that aims at helping the understanding of this phenomenon also called Fuel Coolant Interaction (FCI) by providing data. CEA takes part in this program by performing tests in its KROTOS facility where steam explosions using prototypic corium can be triggered. Data about the different phases in the premixing are extracted from the KROTOS X-Ray radioscopy images by using KIWI software (KROTOS Image analysis of Water-corium Interaction) currently developed by CEA. The MC3D code, developed by IRSN, is a thermal-hydraulic multiphase code mainly dedicated to FCI studies. It is composed of two applications: premixing and explosion. An overall FCI calculation with MC3D requires a premixing calculation followed by an explosion calculation. The present paper proposes an alternative approach in which all the features of the premixing are extracted from the X-Ray pictures using the KIWI software and transferred to an MC3D dataset for a direct simulation of the explosion. The main hypothesis are discussed as well as the first explosion results obtained with MC3D for the KROTOS KFC test. These results are rather encouraging and are analyzed on the basis of comparisons with the experimental data. (authors)

  15. GAMANAL-PC: a program for gamma-ray spectrum analysis using a microcomputer

    International Nuclear Information System (INIS)

    Heimlich, M.; Beeley, P.A.; Page, J.A.

    1989-01-01

    GAMANAL was modified to operate on a microcomputer. The program uses an algorithm involving a Gaussian and a tailing term for fitting and resolving peaks obtained from spectrometers using Ge semiconductor detectors. Gamma-ray energies, intensities and absolute photon emission rates can be determined. A graphical output showing the original and fitted data can also be obtained. The results generated by the program are stored on disk as ASCII files for further analysis. This allows the use of other computer programs and languages in tasks such as decay curve analysis, radionuclide activity measurements and neutron activation analysis. (author) 11 refs.; 2 figs.; 4 tabs

  16. The Aphrodite boiling crisis program. Analysis of CHF tests performed on a vertical tube

    International Nuclear Information System (INIS)

    Souyri, A.; Conan, S.; Portesse, A.; Tremblay, D.

    1992-09-01

    In order to develop a comprehensive modelling of the boiling crisis phenomenon, the APHRODITE experimental program has been set up at ELECTRICITE DE FRANCE. Aiming at a better mechanistic understanding of this phenomenon, this program will investigate the influence of the experimental conditions (among which the mockup geometry and the boundary conditions) and the two-phase flow patterns via void fraction distributions. It has involved the construction of a R12 test loop, which can deliver a large thermal-hydraulic parameter ranges, and the development of a gamma-ray tomograph. The first experiments have been carried out on a vertical Inconel tube, 6 meters long with a bore diameter of 13 mm and a thickness of 0.5 mm. This electrically heated test section is heavily instrumented with 168 thermocouples welded along the tube, on its outer surface. After a refined calibration of the experimental procedure, a critical heat flux data bank has been collected within large pressure, mass velocity and critical steam quality ranges. These results are firstly compared with other CHF data obtained in similar conditions. Then several empirical correlations and a theoretical model for similar prediction in tubes are tested against these data

  17. Metrological analysis of constancy tests in conventional medical X-ray equipment

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Oliveira, Paulo Marcio C.; Squair, Peterson L.; Soares, Carlos M.; Silva, Teogenes A. da

    2005-01-01

    Constancy tests in x-ray diagnostic machines should follow performance requirements with the aim to verify their safety and quality and to protect workers, patients and public members that are or may be exposed to ionizing radiation risks. In the Brazilian state of Minas Gerais, from 1999 to 2004, 110 radiometric and evaluation reports of x-ray machines were issued by accredited professionals. Most of the reports did not provide the estimation of the measurement uncertainty that should be part of the results; it means that there is a lack of metrological care in such reports which may cause difficulties to get a conclusive analysis. In this work, relevant sources of uncertainties were identified and estimated for the following tests carried out in a conventional x-ray machine: high voltage accuracy and reproducibility, air kerma rate repeatability and linearity and half-value layer determination. This work gives details on the methodology and the expanded and combined uncertainty values for each measuring procedure, which may be adopted as representative values for analysis of radiometric report. (author)

  18. Radiobiology of ultrasoft X-rays

    International Nuclear Information System (INIS)

    Raju, M.R.; Carpenter, S.; Chmielewski, J.; Schillaci, M.; Wilder, M.

    1985-01-01

    The goal of this program is to elucidate the principal physical, chemical, and biological mechanisms of radiation action in cells. The basic experiments for this program involve selected low- and high-energy x-ray sources and include studies of cell killing, both with and without modifiers (for example, hypoxia), determination of cellular age response, and measurement of induced DNA strand breaks, mutations, and chromosome aberrations. The theoretical effort involves Monte Carlo-based radiation track simulation codes to generate energy-deposition events and to follow the subsequent diffusion of chemical species. By combining the experimental and theoretical results, the authors plan to test assumptions used in existing models and to determine important parameters that should be included in any model. Ultrasoft x-rays (less than a few kiloelectron volts) provide a unique tool for studying induced biological lesions because x-rays produce photoelectrons with ranges much shorter than cellular dimensions but equivalent to the size of DNA strands and metaphase chromosomes

  19. Study of test-mass charging process in the LISA missions due to diffuse γ-rays

    International Nuclear Information System (INIS)

    Finetti, N; Scrimaglio, R; Grimani, C; Fabi, M

    2009-01-01

    Gravitational inertial sensors will be placed on board the Laser Interferometer Space Antenna (LISA) and aboard its precursor mission LISA Pathfinder (LISA-PF) in order to detect low frequency gravitational waves in space. Free-floating test-masses (Au 7 Pt 3 cubes) will be housed in inertial sensors for detecting possible laser signal variations induced by gravitational waves. Charging of the LISA test-masses due to exposure of the spacecraft to cosmic radiation and energetic solar particles will affect operation of gravitational inertial sensors. In this paper we report on the role of diffuse γ-rays in charging the LISA and LISA-PF test-masses with respect to protons and helium nuclei. The diffuse γ-ray flux in the Galaxy has been interpolated taking into account the outcomes of recent calculations. A comparison with γ-ray observations gathered by different experiments (COMPTEL and EGRET, Milagro, Whipple, HEGRA, TIBET) has been carried out. Simulations of the test-mass charging process have been performed by means of the FLUKA2006.3b package. Monte Carlo simulations of the interaction of cosmic particles with the LISA spacecraft indicate that the diffuse γ-ray contribution to the average steady-state test-mass charging rate and to the single-sided power spectrum of the charge rate noise is marginal with respect to that due to galactic cosmic-rays.

  20. Non-destructive test for irradiated fuels using X-ray CT system in hot-laboratory

    International Nuclear Information System (INIS)

    Kim, Heemoon; Kim, Gil-Soo; Yoo, Boung-Ok; Tahk, Young-Wook; Cho, Moon-Sung; Ahn, Sang-Bok

    2015-01-01

    To inspect inside of irradiated fuel rod for PIE in hotcell, neutron beam and X-ray have been used. Many hot laboratories in the world have shown the results for NDT by 2-D film data. Currently, computed image processing technology instead of film has been developed and CT was applied to the X-ray and neutron beam system. In this trend, our facility needed to set up X-ray system for irradiated fuel inspection and installed in hotcell with consideration of radiation damage. In this study, X-ray system was tested to be operated with radioactive samples and was performed to inspect fuel rods and observe internal damage and dimensional change. 450kV X-ray CT system was installed in hotcell with modification and tested to check image resolution and radiation damage. The image data were analyzed by 3-D computer software. 8 fuel plates and VHTR rods were inspected and measured internal shape and dimension

  1. The NRU blowdown test facility commissioning program

    Energy Technology Data Exchange (ETDEWEB)

    Walsworth, J A; Zanatta, R J; Yamazaki, A R; Semeniuk, D D; Wong, W; Dickson, L W; Ferris, C E; Burton, D H [Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.

    1990-12-31

    A major experimental program has been established at the Chalk River Nuclear Laboratories (CRL) that will provide essential data on the thermal and mechanical behaviour of nuclear fuel under abnormal reactor operating conditions and on the transient release, transport and deposition of fission product activity from severely degraded fuel. A number of severe fuel damage (SFD) experiments will be conducted within the Blowdown Test Facility (BTF) at CRL. A series of experiments are being conducted to commission this new facility prior to the SFD program. This paper describes the features and the commissioning program for the BTF. A development and testing program is described for critical components used on the reactor test section. In-reactor commissioning with a fuel assembly simulator commenced in 1989 June and preliminary results are given. The paper also outlines plans for future all-effects, in-reactor tests of CANDU-designed fuel. (author). 11 refs., 3 tabs., 7 figs.

  2. SWEPP gamma-ray spectrometer system software test plan and report

    International Nuclear Information System (INIS)

    Femec, D.A.

    1994-09-01

    The SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory to assist in the characterization of the radiological contents of contact-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP). In addition to determining the concentrations of gamma-ray-emitting radionuclides, the software also calculates attenuation-corrected isotopic mass ratios of specific interest, and provides controls for SGRS hardware as required. This document presents the test plan and report for the data acquisition and analysis software associated with the SGRS system

  3. X-ray testing for short-time dynamic applications

    International Nuclear Information System (INIS)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried

    2017-01-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  4. Sheath insulator final test report, TFE Verification Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications.

  5. Sheath insulator final test report, TFE Verification Program

    International Nuclear Information System (INIS)

    1994-07-01

    The sheath insulator in a thermionic cell has two functions. First, the sheath insulator must electrically isolate the collector form the outer containment sheath tube that is in contact with the reactor liquid metal coolant. Second, The sheath insulator must provide for high uniform thermal conductance between the collector and the reactor coolant to remove away waste heat. The goals of the sheath insulator test program were to demonstrate that suitable ceramic materials and fabrication processes were available, and to validate the performance of the sheath insulator for TFE-VP requirements. This report discusses the objectives of the test program, fabrication development, ex-reactor test program, in-reactor test program, and the insulator seal specifications

  6. Multidimensional analysis of high resolution. gamma. -ray data

    Energy Technology Data Exchange (ETDEWEB)

    Flibotte, S.; Huettmeier, U.J.; France, G. de; Haas, B.; Romain, P.; Theisen, C.; Vivien, J.P.; Zen, J. (Centre de Recherches Nucleaires, 67 - Strasbourg (France)); Bednarczyk, P. (Inst. of Nuclear Physics, Krakow (Poland))

    1992-08-15

    Algorithms are developed to analyze high-fold {gamma}-ray coincidences. Performances of the programs have been tested in 3, 4 and 5 dimensions using events generated with a Monte Carlo simulation. (orig.).

  7. Testing of quality of welded joints using heavy-current pulse X-ray apparatuses

    International Nuclear Information System (INIS)

    Gusev, E.A.; Firstov, V.G.

    1988-01-01

    The possibilities of carrying out of radiographic and electroradiographic testing of quality of welded joints using heavy-current pulse X-ray apparatuses under the mode of single pulses are shown. Basic quantitative characteristics of radiographic testing permitting to detect the focus distance, sensitivity behaviour and optical density of image are presented. Peculiarities of electroradiographic image formation under the mode of single pulses of nanosecond range are analysed. The outlook of heavy-current pulse X-ray apparatus application under the mode of single pulses in industry is estimated

  8. Definition study of a Variable Cycle Experimental Engine (VCEE) and associated test program and test plan

    Science.gov (United States)

    Allan, R. D.

    1978-01-01

    The Definition Study of a Variable Cycle Experimental Engine (VCEE) and Associated Test Program and Test Plan, was initiated to identify the most cost effective program for a follow-on to the AST Test Bed Program. The VCEE Study defined various subscale VCE's based on different available core engine components, and a full scale VCEE utilizing current technology. The cycles were selected, preliminary design accomplished and program plans and engineering costs developed for several program options. In addition to the VCEE program plans and options, a limited effort was applied to identifying programs that could logically be accomplished on the AST Test Bed Program VCE to extend the usefulness of this test hardware. Component programs were provided that could be accomplished prior to the start of a VCEE program.

  9. Tests of Imaging with Lobster-Eye X-Ray Optics and MEDIPIX2 Detector

    Czech Academy of Sciences Publication Activity Database

    Tichý, V.; Švéda, L.; Maršík, J.; Jakůbek, J.; Maršíková, V.; Pína, L.; Hudec, René; Hromčík, M.

    2009-01-01

    Roč. 18, 3-4 (2009), s. 369-373 ISSN 1392-0049. [INTEGRAL/BART workshop 2009. Karlovy Vary, 26.03.2009-29.03.2009] Grant - others:GA ČR(CZ) GA102/09/0997; GA Mšk(CZ) ME09028; GA ČR(CZ) GA102/08/0186; GA AV ČR(CZ) IAAX01220701; Mšk(CZ) 1M0567 Program:GA; IA; 1M Institutional research plan: CEZ:AV0Z10030501 Keywords : X-rays * X-rays telescopes * space vehicles Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.032, year: 2009

  10. REX - a program for the analysis of X-ray reflectivity data: user guide and programmer manual

    International Nuclear Information System (INIS)

    Crabb, T.A.; Gibson, P.N.

    1992-12-01

    A FORTRAN program REX, which has been developed to facilitate the interpretation of X-ray reflectivity data, is described. The program allows the simulation of reflectivity profiles as a function of either incident angle or of energy. Factors such as anomalous dispersion, and surface and interface roughness are taken into account in the model. In addition, experimental data of reflectivity as a function of incident angle can be matched to user-supplied theoretical parameters by a least-squares refinement procedure. Experimental reflectivity data recorded at several X-ray wavelengths can be analysed simultaneously, thus eliminating certain experimental errors. (author)

  11. IFE chamber technology testing program in NIF and chamber development test plan

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1995-01-01

    Issues concerning chamber technology testing program in NIF involving: criteria for evaluation/prioritization of experiments, engineering scaling requirements for test article design and material selection and R and D plan prior to NIF testing were addressed in this paper. In order to maximize the benefits of testing program in NIF, the testing in NIF should provide the experimental data relevant to DEMO design choice or to DEMO design predictive capability by utilizing engineering scaling test article designs. Test plans were developed for 2 promising chamber design concepts. Early testing in non-fusion/non-ignition prior to testing in ignition facility serves a critical role in chamber R and D test plans in order to reduce the risks and costs of the more complex experiments in NIF

  12. Multiple x-ray diffraction simulation and applications

    International Nuclear Information System (INIS)

    Costa, C.A.B.S. da.

    1989-09-01

    A computer program (MULTX) was implemented for simulation X-ray multiple diffraction diagrams in Renninger geometries. The program uses the X-ray multiple diffraction theory for imperfect crystals. The iterative calculation of the intensities is based on the Taylor series general term, and the primary beam power expansion is given as function of the beam x penetration in the crystal surface. This development allows to consider the simultaneous interaction of the beams involved in the multiple diffraction phenomenon. The simulated diagrams are calculated point-to-point and the tests for the Si and GaAs presented good reproduction of the experimental diagrams for different primary reflections. (L.C.J.A.)

  13. Chandra X-ray Center Science Data Systems Regression Testing of CIAO

    Science.gov (United States)

    Lee, N. P.; Karovska, M.; Galle, E. C.; Bonaventura, N. R.

    2011-07-01

    The Chandra Interactive Analysis of Observations (CIAO) is a software system developed for the analysis of Chandra X-ray Observatory observations. An important component of a successful CIAO release is the repeated testing of the tools across various platforms to ensure consistent and scientifically valid results. We describe the procedures of the scientific regression testing of CIAO and the enhancements made to the testing system to increase the efficiency of run time and result validation.

  14. The Livermore X-ray Laser Program

    International Nuclear Information System (INIS)

    Matthews, D.L.

    1992-01-01

    I will report on the status of x-ray laser development and its applications at Livermore. I will review some of our recent results and comment on where our future research is headed including plans for developing a compact x-ray laser users facility. Finally, I will briefly summarize the results of an X-ray Laser Applications Workshop that was held in San Francisco in January 1992

  15. Spacecraft Testing Programs: Adding Value to the Systems Engineering Process

    Science.gov (United States)

    Britton, Keith J.; Schaible, Dawn M.

    2011-01-01

    Testing has long been recognized as a critical component of spacecraft development activities - yet many major systems failures may have been prevented with more rigorous testing programs. The question is why is more testing not being conducted? Given unlimited resources, more testing would likely be included in a spacecraft development program. Striking the right balance between too much testing and not enough has been a long-term challenge for many industries. The objective of this paper is to discuss some of the barriers, enablers, and best practices for developing and sustaining a strong test program and testing team. This paper will also explore the testing decision factors used by managers; the varying attitudes toward testing; methods to develop strong test engineers; and the influence of behavior, culture and processes on testing programs. KEY WORDS: Risk, Integration and Test, Validation, Verification, Test Program Development

  16. HARPA: A versatile three-dimensional Hamiltonian ray-tracing program for acoustic waves in the atmosphere above irregular terrain

    Science.gov (United States)

    Jones, R. M.; Riley, J. P.; Georges, T. M.

    1986-08-01

    The modular FORTRAN 77 computer program traces the three-dimensional paths of acoustic rays through continuous model atmospheres by numerically integrating Hamilton's equations (a differential expression of Fermat's principle). The user specifies an atmospheric model by writing closed-form formulas for its three-dimensional wind and temperature (or sound speed) distribution, and by defining the height of the reflecting terrain vs. geographic latitude and longitude. Some general-purpose models are provided, or users can readily design their own. In addition to computing the geometry of each raypath, HARPA can calculate pulse travel time, phase time, Doppler shift (if the medium varies in time), absorption, and geometrical path length. The program prints a step-by-step account of a ray's progress. The 410-page documentation describes the ray-tracing equations and the structure of the program, and provides complete instructions, illustrated by a sample case.

  17. Cooperative field test program for wind systems

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  18. Test Program Set (TPS) Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The ARDEC TPS Laboratory provides an organic Test Program Set (TPS) development, maintenance, and life cycle management capability for DoD LCMC materiel developers....

  19. Calculation of gamma-rays and fast neutrons fluxes with the program Mercure-4

    International Nuclear Information System (INIS)

    Baur, A.; Dupont, C.; Totth, B.

    1978-01-01

    The program MERCURE-4 evaluates gamma ray or fast neutron attenuation, through laminated or bulky three-dimensionnal shields. The method used is that of line of sight point attenuation kernel, the scattered rays being taken into account by means of build-up factors for γ and removal cross sections for fast neutrons. The integration of the point kernel over the range of sources distributed in space and energy, is performed by the Monte-Carlo method, with an automatic adjustment of the importance functions. Since it is operationnal the program MERCURE-4 has been intensively used for many various problems, for example: - the calculation of gamma heating in reactor cores, control rods and shielding screens, as well as in experimental devices and irradiation loops; - the evaluation of fast neutron fluxes and corresponding damage in structural materials of reactors (vessel steels...); - the estimation of gamma dose rates on nuclear instrumentation in the reactors, around the reactor circuits and around spent fuel shipping casks

  20. 77 FR 18793 - Spectrum Sharing Innovation Test-Bed Pilot Program

    Science.gov (United States)

    2012-03-28

    .... 120322212-2212-01] Spectrum Sharing Innovation Test-Bed Pilot Program AGENCY: National Telecommunications... Innovation Test-Bed pilot program to assess whether devices employing Dynamic Spectrum Access techniques can... Spectrum Sharing Innovation Test-Bed (Test-Bed) pilot program to examine the feasibility of increased...

  1. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  2. Characteristics and quality test of X-ray with CZT detector

    International Nuclear Information System (INIS)

    Rianto, Sugeng

    2000-01-01

    The study examines the use of direct measurements of x-ray spectra for testing the quality of x-ray beam by using a peltier-cooled CZT detector under different conditions. The typical calibration of the spectrometry system shows that the energy resolution of the system is 1,2 keV at 122 keV of 57 Co. The utilization CZT based spectrometer for assessing the quality of x-ray machine on its spectra show that the CZT could accurately measure the spectra at various kVp, m As and filtration, except at the kVp greater than 140 and m As higher than 2 without added filtration. A comparison of CZT with the field instruments showed that there is a reasonable agreement between the Keithley and CZT at lower energies regardless of filtration however at high energies there is a large difference.In contrast the discrepancy between the CZT and Nero increased at lower photon energies particularly for high filtration

  3. Programmed Death-Ligand 1 Immunohistochemistry Testing

    DEFF Research Database (Denmark)

    Büttner, Reinhard; Gosney, John R; Skov, Birgit Guldhammer

    2017-01-01

    Purpose Three programmed death-1/programmed death-ligand 1 (PD-L1) inhibitors are currently approved for treatment of non-small-cell lung cancer (NSCLC). Treatment with pembrolizumab in NSCLC requires PD-L1 immunohistochemistry (IHC) testing. Nivolumab and atezolizumab are approved without PD-L1...

  4. Tuning of the cosmic-ray test system of the BESIII drift chamber

    International Nuclear Information System (INIS)

    Wu Zhi; Liu Jianbei; Qin Zhonghua; Wu Linghui; Chen Chang; Chen Yuanbo; Chen Mali; Chen Xihui; Dong Mingyi; Guan Beiju; Huang Jie; Jiang Xiaoshan; Jin Yan; Li Fei; Li Renying; Li Xiaonan; Lei Guangkun; Liu Rongguang; Luo Xiaolan; Ma Xiaoyan; Sheng Huayi; Sun Hansheng; Tang Xiao; Wang Lan; Wang Liang; Xu Meihang; Zhang Jian; Zhang Hongyu; Zhang Yinhong; Zhao Yubin; Zhao Pingping; Zhu Kejun; Zhu Qiming; Zhuang Bao'an

    2010-01-01

    The BESIII drift chamber and its subsystems need a cosmic-ray test after the chamber construction to check the chamber construction quality, testing the joint operation of the whole system and the performance of the chamber. The noise performance, drift time and charge measurements, and the scanning of channels were examined specifically. The preliminary results of the test indicate that the whole system works well. (authors)

  5. NRC Confirmatory Testing Program for SBWR

    International Nuclear Information System (INIS)

    Han, J.T.; Bessette, D.E.; Shotkin, L.M.

    1994-01-01

    The objective of the NRC Confirmatory Testing Program for SBWR is to provide integral data for code assessment, which reasonably reproduce the important phenomena and processes expected in the SBWR under various loss-of-coolant accident (LOCA) and transient conditions. To achieve this objective, the Program consists of four coupled elements: (1) to design and construct an integral, carefully-scaled SBWR test facility at Purdue Univ., (2) to provide pre-construction RELAP5/CONTAIN predictions of the facility design, (3) to provide confirmatory data for code assessment, and (4) to assess the RELAP5/CONTAIN code with data. A description of the open-quotes preliminary designclose quotes of the Purdue test facility and test matrix is presented. The facility is scheduled to be built by December 1994. Approximately 50 tests will be performed from April 1995 through April 1996 and documented by interim data reports. A final and complete data report is scheduled to be published by July 31, 1996

  6. Programs for Testing Processor-in-Memory Computing Systems

    Science.gov (United States)

    Katz, Daniel S.

    2006-01-01

    The Multithreaded Microbenchmarks for Processor-In-Memory (PIM) Compilers, Simulators, and Hardware are computer programs arranged in a series for use in testing the performances of PIM computing systems, including compilers, simulators, and hardware. The programs at the beginning of the series test basic functionality; the programs at subsequent positions in the series test increasingly complex functionality. The programs are intended to be used while designing a PIM system, and can be used to verify that compilers, simulators, and hardware work correctly. The programs can also be used to enable designers of these system components to examine tradeoffs in implementation. Finally, these programs can be run on non-PIM hardware (either single-threaded or multithreaded) using the POSIX pthreads standard to verify that the benchmarks themselves operate correctly. [POSIX (Portable Operating System Interface for UNIX) is a set of standards that define how programs and operating systems interact with each other. pthreads is a library of pre-emptive thread routines that comply with one of the POSIX standards.

  7. Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav, E-mail: sstoupin@aps.anl.gov; Shvyd’ko, Yuri; Trakhtenberg, Emil; Liu, Zunping; Lang, Keenan; Huang, Xianrong; Wieczorek, Michael; Kasman, Elina; Hammonds, John; Macrander, Albert; Assoufid, Lahsen [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-07-27

    We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

  8. Mobile Energy Laboratory energy-efficiency testing programs

    International Nuclear Information System (INIS)

    Parker, G.B.; Currie, J.W.

    1992-03-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the third and fourth quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semi-annual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semi-annually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies

  9. Mobile Energy Laboratory energy-efficiency testing programs

    Energy Technology Data Exchange (ETDEWEB)

    Parker, G B; Currie, J W

    1992-03-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the third and fourth quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semi-annual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semi-annually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies.

  10. Characteristics of X ray calibration fields for performance test of radiation measuring instruments

    International Nuclear Information System (INIS)

    Shimizu, Shigeru; Takahashi, Fumiaki; Sawahata, Tadahiro; Tohnami, Kohichi; Kikuchi, Hiroshi; Murayama, Takashi

    1999-02-01

    Performance test and calibration of the radiation measuring instruments for low energy photons are made using the X ray calibration fields which are monochromatically characterized by filtration of continuous X ray spectrum. The X ray calibration field needs to be characterized by some quality conditions such as quality index and homogeneity coefficient. The present report describes quality conditions, spectrum and some characteristics of X ray irradiation fields in the Facility of Radiation Standard of the Japan Atomic Energy Research Institute (FRS-JAERI). Fifty nine X ray qualities with the quality index of 0.6, 0.7, 0.8 and 0.9 were set for the tube voltages between 10 kV and 350 kV. Estimation of X ray spectrum measured with a Ge detector was made in terms of exposure, ambient dose equivalent and fluence for all the obtained qualities. Practical irradiation field was determined as the dose distribution uniformity is within ±3%. The obtained results improve the quality of X ray calibration fields and calibration accuracy. (author)

  11. BNL NONLINEAR PRE TEST SEISMIC ANALYSIS FOR THE NUPEC ULTIMATE STRENGTH PIPING TEST PROGRAM

    International Nuclear Information System (INIS)

    DEGRASSI, G.; HOFMAYER, C.; MURPHY, C.; SUZUKI, K.; NAMITA, Y.

    2003-01-01

    The Nuclear Power Engineering Corporation (NUPEC) of Japan has been conducting a multi-year research program to investigate the behavior of nuclear power plant piping systems under large seismic loads. The objectives of the program are: to develop a better understanding of the elasto-plastic response and ultimate strength of nuclear piping; to ascertain the seismic safety margin of current piping design codes; and to assess new piping code allowable stress rules. Under this program, NUPEC has performed a large-scale seismic proving test of a representative nuclear power plant piping system. In support of the proving test, a series of materials tests, static and dynamic piping component tests, and seismic tests of simplified piping systems have also been performed. As part of collaborative efforts between the United States and Japan on seismic issues, the US Nuclear Regulatory Commission (USNRC) and its contractor, the Brookhaven National Laboratory (BNL), are participating in this research program by performing pre-test and post-test analyses, and by evaluating the significance of the program results with regard to safety margins. This paper describes BNL's pre-test analysis to predict the elasto-plastic response for one of NUPEC's simplified piping system seismic tests. The capability to simulate the anticipated ratcheting response of the system was of particular interest. Analyses were performed using classical bilinear and multilinear kinematic hardening models as well as a nonlinear kinematic hardening model. Comparisons of analysis results for each plasticity model against test results for a static cycling elbow component test and for a simplified piping system seismic test are presented in the paper

  12. NCAA Drug-Testing Program 2010-11

    Science.gov (United States)

    National Collegiate Athletic Association (NJ1), 2010

    2010-01-01

    The National Collegiate Athletic Association (NCAA) Drug-Testing Program was created to protect the health and safety of student-athletes and to ensure that no one participant might have an artificially induced advantage or be pressured to use chemical substances. This publication describes this program in the following chapters: (1) NCAA…

  13. Spent fuel sabotage aerosol test program :FY 2005-06 testing and aerosol data summary

    International Nuclear Information System (INIS)

    Gregson, Michael Warren; Brockmann, John E.; Nolte, O.; Loiseau, O.; Koch, W.; Molecke, Martin Alan; Autrusson, Bruno; Pretzsch, Gunter Guido; Billone, M. C.; Lucero, Daniel A.; Burtseva, T.; Brucher, W; Steyskal, Michele D.

    2006-01-01

    This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program has been underway for several years. This program provides source-term data that are relevant to some sabotage scenarios in relation to spent fuel transport and storage casks, and associated risk assessments. This document focuses on an updated description of the test program and test components for all work and plans made, or revised, primarily during FY 2005 and about the first two-thirds of FY 2006. It also serves as a program status report as of the end of May 2006. We provide details on the significant findings on aerosol results and observations from the recently completed Phase 2 surrogate material tests using cerium oxide ceramic pellets in test rodlets plus non-radioactive fission product dopants. Results include: respirable fractions produced; amounts, nuclide content, and produced particle size distributions and morphology; status on determination of the spent fuel ratio, SFR (the ratio of respirable particles from real spent fuel/respirables from surrogate spent fuel, measured under closely matched test conditions, in a contained test chamber); and, measurements of enhanced volatile fission product species sorption onto respirable particles. We discuss progress and results for the first three, recently performed Phase 3 tests using depleted uranium oxide, DUO 2 , test rodlets. We will also review the status of preparations and the final Phase 4 tests in this program, using short rodlets containing actual spent fuel from U.S. PWR reactors, with both high- and lower-burnup fuel. These data plus testing results and design are tailored to support and guide, follow-on computer modeling of aerosol dispersal hazards and radiological consequence assessments

  14. Constancy tests radiography X-ray devices with CR system

    International Nuclear Information System (INIS)

    Durdikova, M.; Zakova, M.

    2005-01-01

    The paper presents the changes in QAP (Quality Assurance Program) as consequence of digitalisation of medical facilities. Digitalisation brings many advantages - more comfort for personal use, images are easy achievable and transferable to workstation, fine quality images by postprocessing are easily achievable. But it must be taken into account that due to simplicity of image make it is sometimes taken more images then necessary .There are two possible ways of digitalisation in radiography: to exchange conventional developer machine by Computer Radiography (CR), that means to use CR reader and cassette with phosphor plate - un-direct digitalisation or to use special radiography X-ray devices with flat-panel detector -direct radiography. (authors)

  15. Spiked environmental matrix for use as a reference material for gamma-ray spectrometry: Production and homogeneity test

    International Nuclear Information System (INIS)

    Sobiech-Matura, K.; Máté, B.; Altzitzoglou, T.

    2016-01-01

    The application of a spiking method for reference material production and its utilisation for a food matrix is presented. The raw rice powder was tested by means of γ-ray spectrometry and spiked with a "1"3"7Cs solution. The spiked material was mixed and tested for homogeneity. The future use of the rice powder reference material after the entire characterisation cycle will be for γ-ray spectrometry method validation. - Highlights: • Spiking blank substance with a traceable radioactive solution • Spiked reference material for γ-ray emitting radionuclides in food matrix • Results of the homogeneity tests are presented

  16. Standard test method for nondestructive assay of special nuclear material holdup using Gamma-Ray spectroscopic methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes gamma-ray methods used to nondestructively measure the quantity of 235U, or 239Pu remaining as holdup in nuclear facilities. Holdup occurs in all facilities where nuclear material is processed, in process equipment, in exhaust ventilation systems and in building walls and floors. 1.2 This test method includes information useful for management, planning, selection of equipment, consideration of interferences, measurement program definition, and the utilization of resources (1, 2, 3, 4). 1.3 The measurement of nuclear material hold up in process equipment requires a scientific knowledge of radiation sources and detectors, transmission of radiation, calibration, facility operations and error analysis. It is subject to the constraints of the facility, management, budget, and schedule; plus health and safety requirements; as well as the laws of physics. The measurement process includes defining measurement uncertainties and is sensitive to the form and distribution of the material...

  17. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  18. Helping Students Test Programs That Have Graphical User Interfaces

    Directory of Open Access Journals (Sweden)

    Matthew Thornton

    2008-08-01

    Full Text Available Within computer science education, many educators are incorporating software testing activities into regular programming assignments. Tools like JUnit and its relatives make software testing tasks much easier, bringing them into the realm of even introductory students. At the same time, many introductory programming courses are now including graphical interfaces as part of student assignments to improve student interest and engagement. Unfortunately, writing software tests for programs that have significant graphical user interfaces is beyond the skills of typical students (and many educators. This paper presents initial work at combining educationally oriented and open-source tools to create an infrastructure for writing tests for Java programs that have graphical user interfaces. Critically, these tools are intended to be appropriate for introductory (CS1/CS2 student use, and to dovetail with current teaching approaches that incorporate software testing in programming assignments. We also include in our findings our proposed approach to evaluating our techniques.

  19. Compact X-ray source at STF (Super Conducting Accelerator Test Facility)

    International Nuclear Information System (INIS)

    Urakawa, J

    2012-01-01

    KEK-STF is a super conducting linear accelerator test facility for developing accelerator technologies for the ILC (International Linear Collider). We are supported in developing advanced accelerator technologies using STF by Japanese Ministry (MEXT) for Compact high brightness X-ray source development. Since we are required to demonstrate the generation of high brightness X-ray based on inverse Compton scattering using super conducting linear accelerator and laser storage cavity technologies by October of next year (2012), the design has been fixed and the installation of accelerator components is under way. The necessary technology developments and the planned experiment are explained.

  20. The accreditation programs and proficiency test in Taiwan for personnel dosimeter services (1991-1998)

    International Nuclear Information System (INIS)

    Lee, B.T.; Hwang, W.S.; Su, S.H.

    2000-01-01

    According to the ionizing radiation safety regulation approved by the ROC Atomic Energy Council (AEC), personnel dosimeter processors shall be accredited by the Chinese National Laboratory Accreditation (CNLA) program before offering dosimeter services and shall be accredited every two years (now has been rescheduled to be every three years since 1996). The aim of this program is to secure quality and technical capability of personnel dosimeters, and to provide systematic improvement for the internal calibration and testing laboratory applying for accreditation by means of assessment procedures. The criteria used to evaluate the capability at laboratories are ISO/IEC 25 (1990) and technical guide in different accreditation fields. The Institute of Nuclear Energy Research (INER) was entrusted by CNLA as the central laboratory to perform the proficiency test of personnel dosimeters for laboratory accreditation in December 1990. Such proficiency tests, based on ANSI N13.11 (1983), which is mainly separated to accident categories and protection categories which consists of eight parts of tests including single and mixture radiation of x-ray, gamma, beta and neutron, have been conducted four times, in 1991, 1993, 1995 and 1998. This paper deals with the test procedures and results of proficiency tests of personnel dosimeters from 1991 until 1998. The results of the four proficiency tests showed that, for accident categories, the pass rate is about 91%; for protection categories, the pass rate is about 98%. Meanwhile, the central laboratory will adopt a new version of HPS N13.11 (1993) to replace ANSI N13.11 (1983) as new criteria for the next proficiency test to be conducted in 2001. (author)

  1. Accelerated Leach Test(s) Program. Annual report

    International Nuclear Information System (INIS)

    Dougherty, D.R.; Fuhrmann, M.; Colombo, P.

    1985-09-01

    This report summarizes the work performed for the Accelerated Leach Test(s) Program at Brookhaven National Laboratory in Fiscal Year 1985 under the sponsorship of the US Department of Energy's Low-Level Waste Management Program (LLWMP). Programmatic activities were concentrated in three areas, as listed and described in the following paragraphs. (1) A literature survey of reported leaching mechanisms, available mathematical models and factors that affect leaching of LLW forms has been compiled. Mechanisms which have been identified include diffusion, dissolution, ion exchange, corrosion and surface effects. Available mathematical models are based on diffusion as the predominant mechanism. Although numerous factors that affect leaching have been identified, they have been conveniently categorized as factors related to the entire leaching system, to the leachant or to the waste form. A report has been published on the results of this literature survey. (2) A computerized data base of LLW leaching data and mathematical models is being developed. The data are being used for model evaluation by curve fitting and statistical analysis according to standard procedures of statistical quality control. (3) Long-term tests on portland cement, bitumen and vinyl ester-styrene (VES) polymer waste forms are underway which are designed to identify and evaluate factors that accelerate leaching without changing the mechanisms. Results on the effect of temperature on leachability indicate that the leach rates of cement and VES waste forms increase with increasing temperature, whereas, the leach rate of bitumen is little affected

  2. X-Ray Optics at NASA Marshall Space Flight Center

    Science.gov (United States)

    O'Dell, Stephen L.; Atkins, Carolyn; Broadway, David M.; Elsner, Ronald F.; Gaskin, Jessica A.; Gubarev, Mikhail V.; Kilaru, Kiranmayee; Kolodziejczak, Jeffery J.; Ramsey, Brian D.; Roche, Jacqueline M.; hide

    2015-01-01

    NASA's Marshall Space Flight Center (MSFC) engages in research, development, design, fabrication, coating, assembly, and testing of grazing-incidence optics (primarily) for x-ray telescope systems. Over the past two decades, MSFC has refined processes for electroformed-nickel replication of grazing-incidence optics, in order to produce high-strength, thin-walled, full-cylinder x-ray mirrors. In recent years, MSFC has used this technology to fabricate numerous x-ray mirror assemblies for several flight (balloon, rocket, and satellite) programs. Additionally, MSFC has demonstrated the suitability of this technology for ground-based laboratory applications-namely, x-ray microscopes and cold-neutron microscopes and concentrators. This mature technology enables the production, at moderately low cost, of reasonably lightweight x-ray telescopes with good (15-30 arcsecond) angular resolution. However, achieving arcsecond imaging for a lightweight x-ray telescope likely requires development of other technologies. Accordingly, MSFC is conducting a multi-faceted research program toward enabling cost-effective production of lightweight high-resolution x-ray mirror assemblies. Relevant research topics currently under investigation include differential deposition for post-fabrication figure correction, in-situ monitoring and control of coating stress, and direct fabrication of thin-walled full-cylinder grazing-incidence mirrors.

  3. Collider Dipole Magnet test program from development through production

    International Nuclear Information System (INIS)

    Bailey, R.E.

    1991-01-01

    Verification of CDM performance, reliability, and magnet production processes will be accomplished during the development phase of the program. Key features of this program include thorough in process testing of magnet subassemblies, verification of the magnetic field quality, and demonstration of the CDM performance during the formal qualification program. Reliability demonstration of the CDM design includes component tests and an accelerated life test program. Prototype magnet phase will address achievement of magnet performance goals through a program of fabrications, test, analysis, redesign as required and procurement of modified parts for a second fabrication run. This process would be repeated again if necessary, and would conclude with a final design for the production magnets. Production process validation will address the effects that key production processes have upon magnet performance, using the magnets produced during the Preproduction phase

  4. DWPF Stage 2: precipitation test program at Mott

    International Nuclear Information System (INIS)

    Schmitz, M.A.

    1981-01-01

    This memorandum covers the results of the test program conducted at Mott Metallurgical to determine cross-flow filter performance on potassium/cesium tetraphenylborate (K/Cs TPB)-sodium titanate slurries. The test program was designed to provide essential basic operating data to supplement the 1000-gallon cold process tests planned at TNX and the shielded cell tests with actual waste supernate planned by Chemical Technology. The specific Mott Metallurgical test objectives are outlined in DPST-81-722. During the Mott Metallurgical test program an average filtrate flow rate of approximately 0.05 gpm/ft 2 was repeatedly demonstrated over an 8-hr run with 0.5 micron filter elements. Initial Fe/Al sludge concentrations up to 150 ppM did not affect filter performance. Rheologies of the K/Cs TPB-sodium titanate slurries up to 13% by weight, the maximum concentration achieved, are summarized. Several recommendations are made to act as a guide for optimal filter performance

  5. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  6. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  7. The advanced test reactor strategic evaluation program

    International Nuclear Information System (INIS)

    Buescher, B.J.

    1989-01-01

    Since the Chernobly accident, the safety of test reactors and irradiation facilities has been critically evaluated from the public's point of view. A systematic evaluation of all safety, environmental, and operational issues must be made in an integrated manner to prioritize actions to maximize benefits while minimizing costs. Such a proactive program has been initiated at the Advanced Test Reactor (ATR). This program, called the Strategic Evaluation Program (STEP), is being conducted for the ATR to provide integrated safety and operational reviews of the reactor against the standards applied to licensed commercial power reactors. This has taken into consideration the lessons learned by the US Nuclear Regulatory Commission (NRC) in its Systematic Evaluation Program (SEP) and the follow-on effort known as the Integrated Safety Assessment Program (ISAP). The SEP was initiated by the NRC to review the designs of older operating nuclear power plants to confirm and document their safety. The ATR STEP objectives are discussed

  8. V/V(max) test applied to SMM gamma-ray bursts

    Science.gov (United States)

    Matz, S. M.; Higdon, J. C.; Share, G. H.; Messina, D. C.; Iadicicco, A.

    1992-01-01

    We have applied the V/V(max) test to candidate gamma-ray bursts detected by the Gamma-Ray Spectrometer (GRS) aboard the SMM satellite to examine quantitatively the uniformity of the burst source population. For a sample of 132 candidate bursts identified in the GRS data by an automated search using a single uniform trigger criterion we find average V/V(max) = 0.40 +/- 0.025. This value is significantly different from 0.5, the average for a uniform distribution in space of the parent population of burst sources; however, the shape of the observed distribution of V/V(max) is unusual and our result conflicts with previous measurements. For these reasons we can currently draw no firm conclusion about the distribution of burst sources.

  9. Automated [inservice testing] IST program

    International Nuclear Information System (INIS)

    Wright, W.M.

    1990-01-01

    There are two methods used to manage a Section XI program: Manual and Automated. The manual method usually consists of hand written records of test results and scheduling requirements. This method while initially lower in cost, results in problems later on in the life of a plant as data continues to accumulate. Automation allows instant access to forty years of test results. Due to the lower cost and higher performance of todays' personal computers, an automated method via a computer program provides an excellent method for managing the vast amount of data that accumulates over the forty year life of a plant. Through the use of a computer, special functions involving this data are available, which through a manual method would not be practical. This paper will describe some of the advantages in using a computer program to manage the Section XI 1ST program. The ISTBASE consists of program code and numerous databases. The source code is written and complied in CLIPPER (tm) language. Graphing routines are performed by dGE (tm) graphics library. Graphs are displayed in EGA form. Since it was estimated that the total complied code, would exceed 640K of ram, overlays through the use of modular programming were used to facilitate the DOS restrictions of 640K ram. The use of overlays still require the user to gain access to ISTBASE through the PASSWORD module. The database files are designed to be compatible with dBASE III+ (tm) data structure. This allows transfer of data between ISTBASE and other database managers/applications. A math co-processor is utilized to speed up calculations on graphs and other mathematical calculations. Program code and data files require a hard disk drive with at least 28 Meg capacity. While ISTBASE will execute on a 8088 based computer, an 80286 computer with a 12 MHz operating speed should be considered the minimum system configuration

  10. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Science.gov (United States)

    Guimarães, M. C.; Silva, C. R. E.; Rosado, P. H. G.; Cunha, P. G.; Da Silva, T. A.

    2018-03-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work.

  11. Quality control of diagnostic x-ray units

    International Nuclear Information System (INIS)

    Marinkovic, O.; Milacic, S.; Jovicic, D.; Tanaskovic, I.

    2001-01-01

    The quality control program for diagnostic x-ray units has started at the Institute of Occupational and Radiological Health during 1990. It includes, among other measurements, reproducibility of dose, high voltage and exposure time. Dose reproducibility was less than 5% for 70% of tested x-ray units. The exposure time and high voltage reproducibility were less than 5% in 60% cases. The cassettes with amplifying foils made from components of rare earth are used in 10% of all x-ray departments. It is very important to work as much as it is possible to modernize general infrastructure as the radiological protection of patients would be better. (author)

  12. PBF/LOFT Lead Rod Test Program experiment operating specification

    International Nuclear Information System (INIS)

    Varacalle, D.J. Jr.

    1978-11-01

    The PBF/LOFT Lead Rod (LLR) Test Program is being conducted to provide experimental information on the behavior of nuclear fuel under normal and accident conditions in the Power Burst Facility at the Idaho National Engineering Laboratory. Understanding the behavior of light-water reactors (LWR) under loss-of-coolant conditions is a major objective of the NRC Reactor Safety Research Program. The Loss of Fluid Test (LOFT) facility is the major testing facility to evaluate the systems response of an LWR over a wide range of Loss of Coolant Experment (LOCE) conditions. As such, the LOFT core is intended to be used for sequential LOCE tests provided no significant fuel rod failures occur. The PFB/LLR tests are designed to simulate the test conditions for the LOFT Power Ascension Tests L2-2 through L2-5. The test program has been designed to provide a parametric evaluation of the LOFT fuel over a wide range of power. Thus, a relatively accurate assessment of the state of the LOFT core after the completion of each subtest and the anticipated effect of the next test can be obtained by utilizing a combination of LLR test data and analytical predictions. Specifications for the test program are presented

  13. Plutonium Immobilization Program cold pour tests

    International Nuclear Information System (INIS)

    Hovis, G.L.; Stokes, M.W.; Smith, M.E.; Wong, J.W.

    1999-01-01

    The Plutonium Immobilization Program (PIP) is a joint venture between the Savannah River Site, Lawrence Livermore National Laboratory, Argonne National Laboratory, and Pacific Northwest National Laboratory to carry out the disposition of excess weapons-grade plutonium. This program uses the can-in-canister (CIC) approach. CIC involves encapsulating plutonium in ceramic forms (or pucks), placing the pucks in sealed stainless steel cans, placing the cans in long cylindrical magazines, latching the magazines to racks inside Defense Waste Processing Facility (DWPF) canisters, and filling the DWPF canisters with high-level waste glass. This process puts the plutonium in a stable form and makes it attractive for reuse. At present, the DWPF pours glass into empty canisters. In the CIC approach, the addition of a stainless steel rack, magazines, cans, and ceramic pucks to the canisters introduces a new set of design and operational challenges: All of the hardware installed in the canisters must maintain structural integrity at elevated (molten-glass) temperatures. This suggests that a robust design is needed. However, the amount of material added to the DWPF canister must be minimized to prevent premature glass cooling and excessive voiding caused by a large internal thermal mass. High metal temperatures, minimizing thermal mass, and glass flow paths are examples of the types of technical considerations of the equipment design process. To determine the effectiveness of the design in terms of structural integrity and glass-flow characteristics, full-scale testing will be conducted. A cold (nonradioactive) pour test program is planned to assist in the development and verification of a baseline design for the immobilization canister to be used in the PIP process. The baseline design resulting from the cold pour test program and CIC equipment development program will provide input to Title 1 design for second-stage immobilization. The cold pour tests will be conducted in two

  14. A measurement control program for plutonium isotopic gamma-ray systems at the Rocky Flats Plant

    International Nuclear Information System (INIS)

    Fleissner, J.G.

    1986-01-01

    A sound measurement control (MC) program should be an integral part of every nondestructive assay measurement system used for the assay of special nuclear materials. This paper describes a measurement control program for plutonium isotopic composition measurements, using high-resolution gamma-ray spectroscopy, that has been implemented in the Analytical Laboratories and the Chemistry Standards Laboratory at the Rocky Flats Plant. This MC program emphasizes the standardization of data collection procedures along with the implementation of internal and external measurement control checks to provide the requisite measurement quality assurance

  15. Evaluation of a Secure Laptop-Based Testing Program in an Undergraduate Nursing Program: Students' Perspective.

    Science.gov (United States)

    Tao, Jinyuan; Gunter, Glenda; Tsai, Ming-Hsiu; Lim, Dan

    2016-01-01

    Recently, the many robust learning management systems, and the availability of affordable laptops, have made secure laptop-based testing a reality on many campuses. The undergraduate nursing program at the authors' university began to implement a secure laptop-based testing program in 2009, which allowed students to use their newly purchased laptops to take quizzes and tests securely in classrooms. After nearly 5 years' secure laptop-based testing program implementation, a formative evaluation, using a mixed method that has both descriptive and correlational data elements, was conducted to seek constructive feedback from students to improve the program. Evaluation data show that, overall, students (n = 166) believed the secure laptop-based testing program helps them get hands-on experience of taking examinations on the computer and gets them prepared for their computerized NCLEX-RN. Students, however, had a lot of concerns about laptop glitches and campus wireless network glitches they experienced during testing. At the same time, NCLEX-RN first-time passing rate data were analyzed using the χ2 test, and revealed no significant association between the two testing methods (paper-and-pencil testing and the secure laptop-based testing) and students' first-time NCLEX-RN passing rate. Based on the odds ratio, however, the odds of students passing NCLEX-RN the first time was 1.37 times higher if they were taught with the secure laptop-based testing method than if taught with the traditional paper-and-pencil testing method in nursing school. It was recommended to the institution that better quality of laptops needs to be provided to future students, measures needed to be taken to further stabilize the campus wireless Internet network, and there was a need to reevaluate the Laptop Initiative Program.

  16. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Rosado, P.H.G.; Cunha, P.G. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  17. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    International Nuclear Information System (INIS)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da; Rosado, P.H.G.; Cunha, P.G.

    2017-01-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  18. Testing the Paradigm that Ultraluminous X-Ray Sources as a Class Represent Accreting Intermediate-Mass Black Holes

    Science.gov (United States)

    Berghea, C. T.; Weaver, K. A.; Colbert, E. J. M.; Roberts, T. P.

    2008-11-01

    To test the idea that ultraluminous X-ray sources (ULXs) in external galaxies represent a class of accreting intermediate-mass black holes (IMBHs), we have undertaken a program to identify ULXs and a lower luminosity X-ray comparison sample with the highest quality data in the Chandra archive. We establish as a general property of ULXs that the most X-ray-luminous objects possess the flattest X-ray spectra (in the Chandra bandpass). No prior sample studies have established the general hardening of ULX spectra with luminosity. This hardening occurs at the highest luminosities (absorbed luminosity >=5 × 1039 erg s-1) and is in line with recent models arguing that ULXs are actually stellar mass black holes. From spectral modeling, we show that the evidence originally taken to mean that ULXs are IMBHs—i.e., the "simple IMBH model"—is nowhere near as compelling when a large sample of ULXs is looked at properly. During the last couple of years, XMM-Newton spectroscopy of ULXs has to a large extent begun to negate the simple IMBH model based on fewer objects. We confirm and expand these results, which validates the XMM-Newton work in a broader sense with independent X-ray data. We find that (1) cool-disk components are present with roughly equal probability and total flux fraction for any given ULX, regardless of luminosity, and (2) cool-disk components extend below the standard ULX luminosity cutoff of 1039 erg s-1, down to our sample limit of 1038.3 erg s-1. The fact that cool-disk components are not correlated with luminosity damages the argument that cool disks indicate IMBHs in ULXs, for which strong statistical support was never found.

  19. Test results of Nb3Sn ribbons for the Princeton D coil test program

    International Nuclear Information System (INIS)

    Kaugerts, J.; File, J.; Willard, J.W.

    1974-10-01

    A previously described D coil test program was modified. Details of a smaller Nb 3 Sn D coil test program are described. Cusp coil tests were made with several Nb 3 Sn composite ribbons. Measurements of both the quench and recovery currents as a function of magnetic field component perpendicular to the wide edge of the ribbon are presented. (auth)

  20. Properties of a large NaI(Tl) spectrometer for the energy measurement of high-energy gamma rays on the Gamma Ray Observatory

    International Nuclear Information System (INIS)

    Hughes, E.B.; Finman, L.C.; Hofstadter, R.; Lepetich, J.E.; Lin, Y.C.; Mattox, J.R.; Nolan, P.L.; Parks, R.; Walker, A.H.

    1986-01-01

    A large NaI(T1) spectrometer is expected to play a crucial role in the measurement of the energy spectra from an all-sky survey of high-energy celestial gamma rays on the Gamma Ray Observatory. The crystal size and requirements of space flight have resulted in a novel crystal-packaging and optics combination. The structure of this spectrometer and the operating characteristics determined in a test program using high energy positrons are described

  1. GAUSS VIII: a computer program for the nuclide activity analysis of γ-ray spectra from GE semiconductor spectrometers

    International Nuclear Information System (INIS)

    Putman, M.H.; Helmer, R.G.; McCullagh, C.M.

    1985-12-01

    A description is given of a computer program, GAUSS VII, which has been written to determine nuclide or isotopic activities from γ-ray spectra from GE semiconductor spectrometers. The preliminary portion of the program can determine the energy- and width-calibration equations, locate individual peaks and define ''peak regions'' that are significantly above the local spectral background. The user may edit these lists of peaks and regions. Each peak region is fitted with one or more components in which the peaks are represented by a Gaussian function or a Gaussian with one or two additive exponential tails on the low-energy side and one on the high-energy side. A step-like background function can be used with each component. The program will automatically recycle to add one or more components to a region if needed to improve the fit. The γ-ray energies and intensities are computed from the resulting Gaussian positions and peak areas. From a comparison of these peak energies and the γ-ray energies for various nuclides in a nuclide library, the nuclides that may be present are identified. The user may edit this nuclide list. The program identifies secondary γ rays that should be present for these nuclides and obtains peak areas for them, if the areas are not already available. All of the peak areas are then analyzed to obtain the best nuclidic activities. The peak areas for any one nuclide and those for nuclides that have interfering lines are analyzed in one least-squares ft. Nuclides whose activities are essentially 0, and peaks which cannot be accounted for are removed from the analysis. Besides the nuclidic activities, a peak-by-peak summary is provided. This program is intended to analyze large groups of spectra as well as an individual spectrum

  2. The MuCool Test Area and RF Program

    International Nuclear Information System (INIS)

    Torun, Y.; Huang, D.; Norem, J.; Palmer, Robert B.; Stratakis, Diktys; Bross, A.; Chung, M.; Jansson, A.; Moretti, A.; Yonehara, K.; Li, D.

    2010-01-01

    The MuCool RF Program focuses on the study of normal conducting RF structures operating in high magnetic field for applications in muon ionization cooling for Neutrino Factories and Muon Colliders. Here we give an overview of the program, which includes a description of the test facility and its capabilities, the current test program, and the status of a cavity that can be rotated in the magnetic field, which allows for a detailed study of the maximum stable operating gradient vs. magnetic field strength and angle.

  3. [Problems of X-ray mammology manpower training and management].

    Science.gov (United States)

    Rozhkova, N I

    2014-01-01

    The paper considers the issues of manpower training in X-ray mammology. It mentions staff shortage and no special training, which reduces the efficient activities of X-ray mammographic rooms, as well as shortage of training facilities and no unified educational programs within interdisciplinary integration, inadequate technical equipment in the training facilities, the lack of an accounting system for training higher- and mid-level health workers, as well as engineers. Emphasis is placed on that the educational programs must comply with the organizational forms of testing the specialists to be employed. The introduction of a continuous education system should be accelerated to rule out the decay period of specialists' competence.

  4. New test of Lorentz symmetry using ultrahigh-energy cosmic rays

    Science.gov (United States)

    Anchordoqui, Luis A.; Soriano, Jorge F.

    2018-02-01

    We propose an innovative test of Lorentz symmetry by observing pairs of simultaneous parallel extensive air showers produced by the fragments of ultrahigh-energy cosmic ray nuclei which disintegrated in collisions with solar photons. We show that the search for a cross-correlation of showers in arrival time and direction becomes background free for an angular scale ≲3 ° and a time window O (10 s ) . We also show that if the solar photo-disintegration probability of helium is O (10-5.5) then the hunt for spatiotemporal coincident showers could be within range of existing cosmic ray facilities, such as the Pierre Auger Observatory. We demonstrate that the actual observation of a few events can be used to constrain Lorentz violating dispersion relations of the nucleon.

  5. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  6. Automated Quality Assurance of Medical Digital X-Ray Equipment

    International Nuclear Information System (INIS)

    Zelikman, Mikhail; Kruchinin, Sergey

    2013-06-01

    Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector's output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object's digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital x-ray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector's noise variance and detector's gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector's surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine

  7. Testing Object-Oriented Programs using Dynamic Aspects and Non-Determinism

    DEFF Research Database (Denmark)

    Achenbach, Michael; Ostermann, Klaus

    2010-01-01

    decisions exposing private data. We present an approach that both improves the expressiveness of test cases using non-deterministic choice and reduces design modifications using dynamic aspect-oriented programming techniques. Non-deterministic choice facilitates local definitions of multiple executions...... without parameterization or generation of tests. It also eases modelling naturally non-deterministic program features like IO or multi-threading in integration tests. Dynamic AOP facilitates powerful design adaptations without exposing test features, keeping the scope of these adaptations local to each...... test. We also combine non-determinism and dynamic aspects in a new approach to testing multi-threaded programs using co-routines....

  8. Simultaneous test construction by zero-one programming

    NARCIS (Netherlands)

    Boekkooi-Timminga, Ellen

    1986-01-01

    A method is described for simultaneous test construction using the Operations Research technique zero-one programming. The model for zero-one programming consists of two parts. The first contains the objective function that describes the aspect to be optimized. The second part contains the

  9. Oil spill sorbents: Testing protocol and certification listing program

    International Nuclear Information System (INIS)

    Cooper, D.; Gausemel, I.

    1993-01-01

    Environment Canada's Emergencies Engineering Division is spearheading a program in conjunction with the Canadian General Standards Board that would see the development of a certification and listing program in addition to a national standard for the testing of sorbent materials. Funding for this program is provided by Environment Canada (EC), Canadian Coast Guard (CCG), Marine Spill Response Corporation (MSRC), US Coast Guard (USCG), and US Minerals Management Service (MMS). The test methods are based upon those defined by the American Society for Testing and Materials and previous test methods developed by Environment Canada for our series of reports entitled Selection Criteria and Laboratory Evaluation of Oil Spill Sorbents. This series, which was started in 1975, encompasses a number of commercially available oil spill sorbents tested with different petroleum products and hydrocarbon solvents. The testing program will categorize the sorbents according to their operating characteristics. The main categories are oil spills on water, oil spills on land, and industrial use. The characteristics to be evaluated with the new test protocols include initial and maximum sorption capacities, water pickup, buoyancy, reuse potential, retention profile, disintegration (material integrity), and ease of application and retrieval. In the near future are plans to incorporate changes to the test that would involve increasing the list of test liquids to encompass spills in an industrial setting, in addition to testing sorbent booms and addressing the disposal problem

  10. NedWind 25 Blade Testing at NREL for the European Standards Measurement and Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Musial, W.; Freebury, G.; Beattie, A.G.

    2001-04-19

    In the mid-90s the European community initiated the Standards, Measurements, and Testing (SMT) program to harmonize testing and measurement procedures in several industries. Within the program, a project was carried out called the European Wind Turbine Testing Procedure Development. The second part of that project, called Blade Test Methods and Techniques, included the United States and was devised to help blade-testing laboratories harmonize their testing methods. This report provides the results of those tests conducted by the National Renewable Energy Laboratory.

  11. Framework for a National Testing and Evaluation Program ...

    Science.gov (United States)

    Abstract:The National STEPP Program seeks to improve water quality by accelerating the effective implementation and adoption of innovative stormwater management technologies. Itwill attempt to accomplish this by establishing practices through highly reliable, and cost-effective Stormwater control measures (SCM) testing, evaluation, and verification services. The program will aim to remove barriers to innovation, minimize duplicative performance evaluation needs, increase confidence that regulatory requirements are met by creating consistency among testing and evaluation protocols, and establishing equity between public domain and proprietary SCM evaluation approaches.The Environmental Technology Verification Program, established by the U.S. Environmental Protection Agency (EPA) 18 years ago, was the only national program of its kindin the stormwater sector, but is now defunct, leaving a national leadership void. The STEPP initiative was triggered in part by regulatory demands in the government and private sectors to fill this vacuum. A concerted focus and study of this matter led to the release of a Water Environment Federation (WEF) white paper entitled “Investigation into the Feasibility of a National Testing and Evaluation Program for Stormwater Products and Practices” in February 2014. During this second phase of the STEPP initiative, and with EPA support, five analogous technology evaluation programs related to both stormwater and non-stormwater were an

  12. X-ray Spectroscopy of High-Z Elements on Nike

    Science.gov (United States)

    Aglitskiy, Y.; Weaver, J. L.; Karasik, M.; Serlin, V.; Obenschain, S. P.; Ralchenko, Yu.

    2013-10-01

    Survey X-ray spectrometer covering a spectral range from 0.5 to 19.5 angstroms has been added to the spectroscopic suite of Nike diagnostics. That allows simultaneous observation of both M- and N- spectra of W, Ta and Au with high spectral resolution. Low energy test shots confirmed strong presence of 3-4 transitions of Ni-like W, Ta and Au with X-ray energies as high as 3.5 keV when above mentioned elements were used as the targets. In our continuous effort to support DOE-NNSA's inertial fusion program, the future campaign will cover a wide range of plasma conditions that result in relatively energetic X-ray production. Eventually, absolutely calibrated spectrometers of similar geometry will be fielded at NIF in cooperation with NIF diagnostic group. Work supported by US DOE, Defense Programs.

  13. Design and testing of a compact X-ray diode. 1998 summer research program for high school juniors at the University of Rochester's Laboratory for Laser Energetics. Student research reports

    International Nuclear Information System (INIS)

    Stern, A.

    1999-03-01

    Omega, the University of Rochester's high powered laser dedicated to fusion research gives off x-rays with different energy levels. Measuring the number of x-rays and the energy of each is important in understanding what happens in the target chamber when Omega is fired. Existing x-ray detectors are expensive, big, and cumbersome. Imaging detectors such as x-ray pinhole cameras which record onto film, x-ray framing cameras which make videos, and most often, x-ray streak cameras which measure time dependences of x-rays. They require a lot of maintenance and are difficult to keep operational. Lawrence Livermore National Laboratory has developed the Dante Diode. The Dante diode array on Omega functions as a group of 12 diodes which take up a 24 inch port in the target chamber, making it space-consuming and difficult to move for alternate views. In designing a new detector, space was the main issue. The smallest possible functional diode, without losing accuracy was desired. Since the laser pulse only lasts a few nanoseconds it is important that the x-ray detector have a response time of a few tenths of a nanosecond. Other criteria include that it be easy to use for measuring the energy and number of x-ray photons and that cost be kept down. This report discusses the design process and testing of the new diode

  14. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  15. The Yucca Mountain Project Prototype Testing Program

    International Nuclear Information System (INIS)

    1989-10-01

    The Yucca Mountain Project is conducting a Prototype Testing Program to ensure that the Exploratory Shaft Facility (ESF) tests can be completed in the time available and to develop instruments, equipment, and procedures so the ESF tests can collect reliable and representative site characterization data. This report summarizes the prototype tests and their status and location and emphasizes prototype ESF and surface tests, which are required in the early stages of the ESF site characterization tests. 14 figs

  16. Material testing facilities and programs for plasma-facing component testing

    Science.gov (United States)

    Linsmeier, Ch.; Unterberg, B.; Coenen, J. W.; Doerner, R. P.; Greuner, H.; Kreter, A.; Linke, J.; Maier, H.

    2017-09-01

    Component development for operation in a large-scale fusion device requires thorough testing and qualification for the intended operational conditions. In particular environments are necessary which are comparable to the real operation conditions, allowing at the same time for in situ/in vacuo diagnostics and flexible operation, even beyond design limits during the testing. Various electron and neutral particle devices provide the capabilities for high heat load tests, suited for material samples and components from lab-scale dimensions up to full-size parts, containing toxic materials like beryllium, and being activated by neutron irradiation. To simulate the conditions specific to a fusion plasma both at the first wall and in the divertor of fusion devices, linear plasma devices allow for a test of erosion and hydrogen isotope recycling behavior under well-defined and controlled conditions. Finally, the complex conditions in a fusion device (including the effects caused by magnetic fields) are exploited for component and material tests by exposing test mock-ups or material samples to a fusion plasma by manipulator systems. They allow for easy exchange of test pieces in a tokamak or stellarator device, without opening the vessel. Such a chain of test devices and qualification procedures is required for the development of plasma-facing components which then can be successfully operated in future fusion power devices. The various available as well as newly planned devices and test stands, together with their specific capabilities, are presented in this manuscript. Results from experimental programs on test facilities illustrate their significance for the qualification of plasma-facing materials and components. An extended set of references provides access to the current status of material and component testing capabilities in the international fusion programs.

  17. A Three-Year Program of Micro- and Nano-System Technology Development for X-Ray Astronomy

    Science.gov (United States)

    Canizares, Claude R.

    1997-01-01

    For many years the work at MIT aimed at the development of new concepts and technologies for space experiments in high-energy astrophysics, but not explicitly supported by flight programs, has been supported. This work has yielded new devices and techniques for X-ray astronomy, primarily low-noise, deep-depletion charge-coupled devices (CCDS) for spectrally-resolved X-ray imaging, and high-performance transmission gratings for high-resolution X-ray spectroscopy. Among the most significant recent achievements have been the development by G. Ricker and associates of the X-ray CCD camera flying on ASCA, and currently in development for AXAF and Astro-E, and the development by C. Canizares and associates of thick, 200 nm-period transmission gratings employing the phenomenon of phase shifting for high-resolution X-ray spectroscopy up to energies of 8- 1 0 keV that is essential for the operation of the AXAF High Energy Transmission Grating Spectrometer (HETGS). Through the current SR&T grant, the latter technology is now being extended successfully to the fabrication of 100 nm-period transmission gratings, which have twice the dispersion of the AXAF gratings. We note that, among other outcomes, the modest investments of past SR&T Grants at MIT resulted in the development of the key technologies for fully one-half of the scientific instrumentation on AXAF. In addition, NASA flight programs that have benefited from previous SR&T support at MIT include the SAS 3 X-ray Observatory, which carried the first rotation modulation collimator, the Focal Plane Crystal Spectrometer (FPCS) on the Einstein Observatory, the CCD cameras on ASCA and planned for Astro-E, the High Energy Transient Experiment (HETE), the Solar EUV Monitor on the Solar and Heliospheric Observatory (SOHO), the Medium Energy Neutral Atom imager (MENA) on the Image for Magnetopause-to-aurora Global Exploration (IMAGE) mission, and the recently-approved Two Wide-Angle Imaging Neutral-atom Spectrometers (TWINS

  18. Overview of the program on soft x-ray lasers and their applications at Princeton

    International Nuclear Information System (INIS)

    Suckewer, S.; Ilcisin, K.; Princeton Univ., NJ

    1991-05-01

    In the last several years, rapid progress in the development of soft x-ray lasers (SXL) has been observed at a number of laboratories worldwide. Although SXLs are very ''young'' devices they have already been used for microscopy and holography, and new ideas emerging for broader application of SXLs to microscopy, holography and lithography. This paper describes the work at Princeton University on the development of a soft x-ray imaging transmission microscopy using a SXL as a radiation source and work on the development of a novel soft x-ray reflection microscope and its application to biological cell studies and lithography. Progress in the development of a photopumped VUV laser (60 nm), and programs for the development of a small scale SXL and for the application of a powerful subpicosecond KrF laser system are also discussed. 35 refs., 9 figs., 1 tab

  19. A method to test the performance of an energy-dispersive X-ray spectrometer (EDS).

    Science.gov (United States)

    Hodoroaba, Vasile-Dan; Procop, Mathias

    2014-10-01

    A test material for routine performance evaluation of energy-dispersive X-ray spectrometers (EDS) is presented. It consists of a synthetic, thick coating of C, Al, Mn, Cu, and Zr, in an elemental composition that provides interference-free characteristic X-ray lines of similar intensities at 10 kV scanning electron microscope voltage. The EDS energy resolution at the C-K, Mn-Lα, Cu-Lα, Al-K, Zr-Lα, and Mn-Kα lines, the calibration state of the energy scale, and the Mn-Lα/Mn-Kα intensity ratio as a measure for the low-energy detection efficiency are calculated by a dedicated software package from the 10 kV spectrum. Measurements at various input count rates and processor shaping times enable an estimation of the operation conditions for which the X-ray spectrum is not yet corrupted by pile-up events. Representative examples of EDS systems characterized with the test material and the related software are presented and discussed.

  20. Construction and Test of Low Cost X-Ray Tomography Scanner for Physical-Chemical Analysis and Nondestructive Inspections

    International Nuclear Information System (INIS)

    Oliveira, Jose Martins Jr. de; Martins, Antonio Cesar Germano

    2009-01-01

    X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function-MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device.

  1. Glass sample preparation and performance investigations. [solar x-ray imager

    Science.gov (United States)

    Johnson, R. Barry

    1992-01-01

    This final report details the work performed under this delivery order from April 1991 through April 1992. The currently available capabilities for integrated optical performance modeling at MSFC for large and complex systems such as AXAF were investigated. The Integrated Structural Modeling (ISM) program developed by Boeing for the U.S. Air Force was obtained and installed on two DECstations 5000 at MSFC. The structural, thermal and optical analysis programs available in ISM were evaluated. As part of the optomechanical engineering activities, technical support was provided in the design of support structure, mirror assembly, filter wheel assembly and material selection for the Solar X-ray Imager (SXI) program. As part of the fabrication activities, a large number of zerodur glass samples were prepared in different sizes and shapes for acid etching, coating and polishing experiments to characterize the subsurface damage and stresses produced by the grinding and polishing operations. Various optical components for AXAF video microscope and the x-ray test facility were also fabricated. A number of glass fabrication and test instruments such as a scatter plate interferometer, a gravity feed saw and some phenolic cutting blades were fabricated, integrated and tested.

  2. Radionuclides release from re-irradiated fuel under high temperature and pressure conditions. Gamma-ray measurements of VEGA-5 test

    Energy Technology Data Exchange (ETDEWEB)

    Hidaka, Akihide; Kudo, Tamotsu; Nakamura, Takehiko; Kanazawa, Toru; Kiuchi, Toshio; Uetsuka, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    The VEGA (Verification Experiments of radionuclides Gas/Aerosol release) program is being performed at JAERI to clarify mechanisms of radionuclides release from irradiated fuel during severe accidents and to improve source term predictability. The fifth VEGA-5 test was conducted in January 2002 to confirm the reproducibility of decrease in cesium release under elevated pressure that was observed in the VEGA-2 test and to investigate the release behavior of short-life radionuclides. The PWR fuel of 47 GWd/tU after about 8.2 years of cooling was re-irradiated at Nuclear Safety Research Reactor (NSRR) for 8 hours before the heat-up test. After that, the two pellets of 10.9 g without cladding were heated up to about 2,900 K at 1.0 MPa under the inert He condition. The experiment reconfirmed the decrease in cesium release rate under the elevated pressure. The release data on short-life radionuclides such as Ru-103, Ba-140 and Xe-133 that have never been observed in the previous VEGA tests without re-irradiation was obtained using the {gamma} ray measurement. (author)

  3. Standard test methods for chemical analysis of ceramic whiteware materials using wavelength dispersive X-Ray fluorescence spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 These test methods cover the determination of ten major elements (SiO2, Al2O3, Fe2O3, MgO, CaO, Na2O, K2O, TiO2, P2O5, MnO, and LOI in ceramic whitewares clays and minerals using wavelength dispersive X-ray fluorescence spectrometry (WDXRF). The sample is first ignited, then fused with lithium tetraborate and the resultant glass disc is introduced into a wavelength dispersive X-ray spectrometer. The disc is irradiated with X-rays from an X-ray tube. X-ray photons emitted by the elements in the samples are counted and concentrations determined using previously prepared calibration standards. (1) In addition to 10 major elements, the method provides a gravimetric loss-on-ignition. Note 1—Much of the text of this test method is derived directly from Major element analysis by wavelength dispersive X-ray fluorescence spectrometry, included in Ref (1). 1.2 Interferences, with analysis by WDXRF, may result from mineralogical or other structural effects, line overlaps, and matrix effects. The structure of the...

  4. PBF/LOFT Lead Rod Test Program experiment predictions document

    International Nuclear Information System (INIS)

    Varacalle, D.J.; Cox, W.R.; Niebruegge, D.A.; Seiber, S.J.; Brake, T.E.; Driskell, W.E.; Nigg, D.W.; Tolman, E.L.

    1978-12-01

    The PBF/LOFT Lead Rod (LLR) Test Program is being conducted to provide experimental information on the behavior of nuclear fuel under normal and accident conditions in the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory. The PBF/LLR tests are designed to simulate the test conditions for the LOFT Power Ascension Tests L2-3 through L2-5. The test program has been designed to provide a parametric evaluation of the LOFT fuel (center and peripheral modules) over a wide range of power. This report presents the experiment predictions for the three four-rod LOCA tests

  5. SPSS and SAS programming for the testing of mediation models.

    Science.gov (United States)

    Dudley, William N; Benuzillo, Jose G; Carrico, Mineh S

    2004-01-01

    Mediation modeling can explain the nature of the relation among three or more variables. In addition, it can be used to show how a variable mediates the relation between levels of intervention and outcome. The Sobel test, developed in 1990, provides a statistical method for determining the influence of a mediator on an intervention or outcome. Although interactive Web-based and stand-alone methods exist for computing the Sobel test, SPSS and SAS programs that automatically run the required regression analyses and computations increase the accessibility of mediation modeling to nursing researchers. To illustrate the utility of the Sobel test and to make this programming available to the Nursing Research audience in both SAS and SPSS. The history, logic, and technical aspects of mediation testing are introduced. The syntax files sobel.sps and sobel.sas, created to automate the computation of the regression analysis and test statistic, are available from the corresponding author. The reported programming allows the user to complete mediation testing with the user's own data in a single-step fashion. A technical manual included with the programming provides instruction on program use and interpretation of the output. Mediation modeling is a useful tool for describing the relation between three or more variables. Programming and manuals for using this model are made available.

  6. A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

    Directory of Open Access Journals (Sweden)

    Jai Wan Cho

    2014-01-01

    Full Text Available We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

  7. Microstructure and micromechanics of the heart urchin test from X-ray tomography

    DEFF Research Database (Denmark)

    Müter, D.; Sørensen, H. O.; Oddershede, Jette

    2015-01-01

    The microstructure of many echinoid species has long fascinated scientists because of its high porosity and outstanding mechanical properties. We have used X-ray microtomography to examine the test of Echinocardium cordatum (heart urchin), a burrowing cousin of the more commonly known sea urchins...

  8. RPC HADES-TOF wall cosmic ray test performance

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, A., E-mail: alberto@coimbra.lip.pt [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Belver, D.; Cabanelas, P. [LabCAF, Universidade de Santiago de Compostela, USC, Santiago de Compostela (Spain); Diaz, J. [Instituto de Fisica Corpuscular IFIC (CSIC-Universidad de Valencia), Valencia (Spain); Fonte, P. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Instituto Superior de Engenharia de Coimbra, ISEC, Coimbra (Portugal); Garzon, J.A. [LabCAF, Universidade de Santiago de Compostela, USC, Santiago de Compostela (Spain); Gil, A. [Instituto de Fisica Corpuscular IFIC (CSIC-Universidad de Valencia), Valencia (Spain); Gonzalez-Diaz, D.; Koenig, W.; Kolb, B. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Lopes, L. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Palka, M. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Pereira, A. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); and others

    2012-01-01

    In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m{sup 2}. All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1% (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.

  9. RPC HADES-TOF wall cosmic ray test performance

    International Nuclear Information System (INIS)

    Blanco, A.; Belver, D.; Cabanelas, P.; Díaz, J.; Fonte, P.; Garzon, J.A.; Gil, A.; Gonzalez-Díaz, D.; Koenig, W.; Kolb, B.; Lopes, L.; Palka, M.; Pereira, A.

    2012-01-01

    In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m 2 . All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1% (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.

  10. Status of CCTF test program

    International Nuclear Information System (INIS)

    Murao, Y.; Iguchi, T.; Sugimoto, J.; Akimoto, H.; Okubo, T.; Okabe, K.

    1984-01-01

    The cylindrical core test facility (CCTF) is one of the facilities of the large scale reflood test program which was initiated in April, 1976. The first series of the CCTF test (CCTF CORE I Test) was completed in April, 1981 and the second series (CCTF Core II Test) has been conducted since April, 1982. In the test, the following has been intended to be examined: (1) The conservativeness of the assumption of the safety analysis with the evaluation model (EM) code. (2) The refill and reflood phenomena for analytical modeling of thermo-hydrodynamics in the core and the system. (3) The validity of the models in the EM code and the application to the best estimate code development. In this paper, presented are the quantative evaluation of the REFLA code and the discussion of some CCTF Core II Test results. The REFLA code consists of REFLA-1D core code developed with the results of small scale tests and a simple system model developed with the results of the CCTF Core I Test. The CCTF Core II Test was perfored for developing more realistic model for the alternative ECCS as well as for the cold leg injection type ECCS

  11. 19 CFR 101.9 - Test programs or procedures; alternate requirements.

    Science.gov (United States)

    2010-04-01

    ... basis for selecting participants. (b) NCAP testing. For purposes of conducting an approved test program or procedure designed to evaluate planned components of the National Customs Automation Program (NCAP... publication requirement. For tests affecting the NCAP, notice shall be published in the Federal Register not...

  12. The high level vibration test program

    International Nuclear Information System (INIS)

    Hofmayer, C.H.; Curreri, J.R.; Park, Y.J.; Kato, W.Y.; Kawakami, S.

    1989-01-01

    As part of cooperative agreements between the US and Japan, tests have been performed on the seismic vibration table at the Tadotsu Engineering Laboratory of Nuclear Power Engineering Test Center (NUPEC) in Japan. The objective of the test program was to use the NUPEC vibration table to drive large diameter nuclear power piping to substantial plastic strain with an earthquake excitation and to compare the results with state-of-the-art analysis of the problem. The test model was subjected to a maximum acceleration well beyond what nuclear power plants are designed to withstand. A modified earthquake excitation was applied and the excitation level was increased carefully to minimize the cumulative fatigue damage due to the intermediate level excitations. Since the piping was pressurized, and the high level earthquake excitation was repeated several times, it was possible to investigate the effects of ratchetting and fatigue as well. Elastic and inelastic seismic response behavior of the test model was measured in a number of test runs with an increasing excitation input level up to the limit of the vibration table. In the maximum input condition, large dynamic plastic strains were obtained in the piping. Crack initiation was detected following the second maximum excitation run. Crack growth was carefully monitored during the next two additional maximum excitation runs. The final test resulted in a maximum crack depth of approximately 94% of the wall thickness. The HLVT (high level vibration test) program has enhanced understanding of the behavior of piping systems under severe earthquake loading. As in other tests to failure of piping components, it has demonstrated significant seismic margin in nuclear power plant piping

  13. KNK I Test Program, Final Report Part 1

    International Nuclear Information System (INIS)

    Kathol, W.

    1976-01-01

    The compact sodium cooled nuclear reactor KNK I of the Karlsruhe Research Center reached full power for the first time in February 1974. The goal of KNK I is to collect experience for the construction and operation of larger reactors, such as SNR 300. In order to deepen these experiences, a test program was drawn up and conducted from 1973 until 1975 within the framework of R and D work on the development of fast breeder reactors. The program included individual tasks concerning reactor design, safety instrumentation, irradiation and post-examination as well as behavior of components during operation. The performance of the tests was essentially governed by the licensing procedure imposed under the atomic energy act for the construction and operation of nuclear facilities. This report is the first part of the final report of the test program

  14. Material control and accounting self-test program design

    International Nuclear Information System (INIS)

    Eggers, R.F.; Wilson, R.L.; Byers, K.R.

    1981-01-01

    This paper describes a controversial but potentially beneficial MCandA strategy that has not been widely attempted in the past, called Self-Test. In this strategy a processor of Strategic Special Nuclear Material (SSNM) devises a program of internally administered tests to determine if the MCandA system performs in a reliable, expedient manner in the face of a simulated loss or compromise. Self-Test procedures would include, for example, the actual removal of SSNM from process equipment in order to determine whether the MCandA system will detect the simulated theft. Self-Test programs have several potential problems. However, an approach with the potential for solving many of these problems has been devised and is discussed

  15. Educational Testing of an Auditory Display of Mars Gamma Ray Spectrometer Data

    Science.gov (United States)

    Keller, J. M.; Pompea, S. M.; Prather, E. E.; Slater, T. F.; Boynton, W. V.; Enos, H. L.; Quinn, M.

    2003-12-01

    A unique, alternative educational and public outreach product was created to investigate the use and effectiveness of auditory displays in science education. The product, which allows students to both visualize and hear seasonal variations in data detected by the Gamma Ray Spectrometer (GRS) aboard the Mars Odyssey spacecraft, consists of an animation of false-color maps of hydrogen concentrations on Mars along with a musical presentation, or sonification, of the same data. Learners can access this data using the visual false-color animation, the auditory false-pitch sonification, or both. Central to the development of this product is the question of its educational effectiveness and implementation. During the spring 2003 semester, three sections of an introductory astronomy course, each with ˜100 non-science undergraduates, were presented with one of three different exposures to GRS hydrogen data: one auditory, one visual, and one both auditory and visual. Student achievement data was collected through use of multiple-choice and open-ended surveys administered before, immediately following, and three and six weeks following the experiment. It was found that the three student groups performed equally well in their ability to perceive and interpret the data presented. Additionally, student groups exposed to the auditory display reported a higher interest and engagement level than the student group exposed to the visual data alone. Based upon this preliminary testing,we have made improvements to both the educational product and our evaluation protocol. This fall, we will conduct further testing with ˜100 additional students, half receiving auditory data and half receiving visual data, and we will conduct interviews with individual students as they interface with the auditory display. Through this process, we hope to further assess both learning and engagement gains associated with alternative and multi-modal representations of scientific data that extend beyond

  16. Computer program SCAP-BR for gamma-ray streaming through multi-legged ducts

    International Nuclear Information System (INIS)

    Byoun, T.Y.; Babel, P.J.; Dajani, A.T.

    1977-01-01

    A computer program, SCAP-BR, has been developed at Burns and Roe for the gamma-ray streaming analysis through multi-legged ducts. SCAP-BR is a modified version of the single scattering code, SCAP, incorporating capabilities of handling multiple scattering and volumetric source geometries. It utilizes the point kernel integration method to calculate both the line-of-sight and scattered gamma dose rates by employing the ray tracing technique through complex shield geometries. The multiple scattering is handled by a repeated process of the single scatter method through each successive scatter region and collapsed pseudo source meshes constructed on the relative coordinate systems. The SCAP-BR results have been compared with experimental data for a Z-type (three-legged) concrete duct with a Co-60 source placed at the duct entrance point. The SCAP-BR dose rate predictions along the duct axis demonstrate an excellent agreement with the measured values

  17. 75 FR 59105 - Procedures for Transportation Workplace Drug and Alcohol Testing Programs: Federal Drug Testing...

    Science.gov (United States)

    2010-09-27

    ... 2105-AE03 Procedures for Transportation Workplace Drug and Alcohol Testing Programs: Federal Drug... the Federal workplace drug testing program but also pointed out that ``* * * the Department of.... Executive Order 12866 and Regulatory Flexibility Act This Interim Final Rule is not significant for purposes...

  18. Quantitative determination of minerals in Nevada Test Site samples by x-ray diffraction

    International Nuclear Information System (INIS)

    Pawloski, G.A.

    1983-07-01

    The external standard intensity ratio technique has been developed into a routine procedure for quantitatively determining mineralogic compositions of Nevada Test Site (NTS) samples by x-ray diffraction. This technique used ratios of x-ray intensity peaks from the same run which eliminates many possible errors. Constants have been determined for each of thirteen minerals commonly found in NTS samples - quartz, montmorillonite, illite, clinoptilolite, cristobalite, feldspars, calcite, dolomite, hornblende, kaolinite, muscovite, biotite, and amorphous glass. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of quartz are used to calculate sample composition. The technique has been tested on samples with three to eleven components representative of geologic environments at NTS, and is accurate to 7.0 wt % of the total sample. The minimum amount of each of these minerals detectable by x-ray diffraction has also been determined. QUANTS is a computer code that calculates mineral contents and produces a report sheet. Constants for minerals in NTS samples other than those listed above can easily be determined, and added to QUANTS at any time

  19. Scattered X-ray beam nondestructive testing

    International Nuclear Information System (INIS)

    Harding, G.; Kosanetzky, J.

    1988-01-01

    X-ray scatter interactions generally dominate the linear attenuation coefficient at the photon energies typical of medical and industrial radiography. Specific advantages of X-ray scatter imaging, including a flexible choice of measurement geometry, direct 3D-imaging capability (tomography) and improved information for material characterization, are illustrated with results from Compton and coherent scatter devices. Applications of a Compton backscatter scanner (ComScan) in the aerospace industry and coherent scatter imaging in security screening are briefly considered [pt

  20. Air shower array designed for cosmic ray variation measurements and high energy gamma ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Morello, C; Navarra, G [Consiglio Nazionale delle Ricerche, Turin (Italy). Lab. di Cosmo-Geofisica

    1981-08-15

    We describe an array for performing measurements of counting rates and arrival directions of extensive air showers at primary energy E/sub 0/ approx. equal to 3 x 10/sup 9/ eV. The aim of the research is to study the time variations and the anisotropies of cosmic rays and the observable gamma ray sources in the high energy region. The installation, composed of four large area scintillation counters and completely controlled by a microcomputer system, operates at mountain altitude (3500 m a.s.l.). The preanalysis of data, stability tests and periodic calibrations are performed by on-line programs. The method for obtaining the required stability and the corrections on temperature and gain variations are also described.

  1. Means-Tested Public Assistance Programs and Adolescent Political Socialization.

    Science.gov (United States)

    Barnes, Carolyn Y; Hope, Elan C

    2017-07-01

    In recent years, scholars have pointed to the politically demobilizing effects of means-tested assistance programs on recipients. In this study, we bridge the insights from policy feedback literature and adolescent political socialization research to examine how receiving means-tested programs shapes parent influence on adolescent political participation. We argue that there are differences in pathways to political participation through parent political socialization and youth internal efficacy beliefs for adolescents from households that do or do not receive means-tested assistance. Using data from a nationally representative sample of 536 Black, Latino, and White adolescents (50.8% female), we find that adolescents from means-tested assistance households report less parent political socialization and political participation. For all youth, parent political socialization predicts adolescent political participation. Internal political efficacy is a stronger predictor of political participation for youth from a non-means-tested assistance household than it is for youth from a household receiving means-tested assistance. These findings provide some evidence of differential paths to youth political participation via exposure to means-tested programs.

  2. SEDRX: A computer program for the simulation Si(Li) and Ge(Hp) x-ray detectors efficiency

    International Nuclear Information System (INIS)

    Benamar, M.A.; Benouali, A.; Tchantchane, A.; Azbouche, A.; Tobbeche, S. Centre de Developpement des Techniques Nucleaires, Algiers; Labo. des Techniques Nucleaires)

    1992-12-01

    The difficulties encountered in measuring the x-ray detectors efficiency has motivated to develop a computer program to simulate this parameter. this program computes the efficiency of detectors as a function of energy. the computation of this parameter is based on the fitting coefficients of absorption in the case of photoelectric, coherent and incoherent factors. These coefficients are given by Mc Master library or may be determined by the interpolation based on cubic splines

  3. A monte carlo program for X-rays detection up to 1.4 MeV

    International Nuclear Information System (INIS)

    Manfredotti, C.; Nastasi, U.

    1983-01-01

    A monte carlo program has been developed to simulate X-ray spectral response in semiconductor detectors. Photons in the range from 5 KeV to 1.4 MeV are considered as emitted from a source of zero thickness aligned to the crystal axis and followed untill their complete energy loss or their escape from the crystal. The program allows the optimization of important parameters in a semiconductor detector, the study of influence on the spectra obtained and the determination of the energy behavior of efficiency and energy resolution. Some obtained results have been compared with experimental data

  4. Fabrication of Sparse Readout Detectors for X-ray Astronomy

    Science.gov (United States)

    Burrows, David

    We propose to continue our detector development program in X-ray astronomy. Under our current APRA grant we have fabricated a new read out integrated circuit that is one half of a hybrid CMOS detector. Here we propose to build and test these innovative detectors, which could potentially be flown on future X-ray missions with focused optics and/or large effective area. This proposal supports NASA's goals of technical advancement of technologies suitable for future missions and training of graduate students.

  5. EVALUATION OF REINFORCING EFFECT ON FACEBOLTS FOR TUNNELING USING X-RAY CT AND CENTRIFUGE MODEL TEST

    Science.gov (United States)

    Takano, Daiki; Otani, Jun; Date, Kensuke; Yokot, Yasuhiro; Nagatani, Hideki

    The purpose of this paper is firstly to simulate the tunnel face failure in laboratory with four cases of model tests by pulling out tunnel model from a sandy ground that are without using auxiliary method nor facebolts and using facebolts with three different lengths of bolts, and secondary, to investigate the behavior of model ground using X-ray computed tomography (CT) scanner to visualize the failure zone in three dimensions. In addition to those results, a series of centrifuge model tests are conducted to confirm the results of X-ray CT test and also to discuss the ground behavior under full scale stress level. Finally, the effect of face bolting method is evaluated based on all the test results.

  6. Affordable and Lightweight High-Resolution X-ray Optics for Astronomical Missions

    Science.gov (United States)

    Zhang, W. W.; Biskach, M. P.; Bly, V. T.; Carter, J. M.; Chan, K. W.; Gaskin, J. A.; Hong, M.; Hohl, B. R.; Jones, W. D.; Kolodziejczak, J. J.

    2014-01-01

    Future x-ray astronomical missions require x-ray mirror assemblies that provide both high angular resolution and large photon collecting area. In addition, as x-ray astronomy undertakes more sensitive sky surveys, a large field of view is becoming increasingly important as well. Since implementation of these requirements must be carried out in broad political and economical contexts, any technology that meets these performance requirements must also be financially affordable and can be implemented on a reasonable schedule. In this paper we report on progress of an x-ray optics development program that has been designed to address all of these requirements. The program adopts the segmented optical design, thereby is capable of making both small and large mirror assemblies for missions of any size. This program has five technical elements: (1) fabrication of mirror substrates, (2) coating, (3) alignment, (4) bonding, and (5) mirror module systems engineering and testing. In the past year we have made progress in each of these five areas, advancing the angular resolution of mirror modules from 10.8 arc-seconds half-power diameter reported (HPD) a year ago to 8.3 arc-seconds now. These mirror modules have been subjected to and passed all environmental tests, including vibration, acoustic, and thermal vacuum. As such this technology is ready for implementing a mission that requires a 10-arc-second mirror assembly. Further development in the next two years would make it ready for a mission requiring a 5-arc-second mirror assembly. We expect that, by the end of this decade, this technology would enable the x-ray astrophysical community to compete effectively for a major x-ray mission in the 2020s that would require one or more 1-arc-second mirror assemblies for imaging, spectroscopic, timing, and survey studies.

  7. LWR aerosol containment experiments (LACE) program and initial test results

    International Nuclear Information System (INIS)

    Muhlestein, L.D.; Hilliard, R.K.; Bloom, G.R.; McCormack, J.D.; Rahn, F.J.

    1985-01-01

    The LWR aerosol containment experiments (LACE) program is described. The LACE program is being performed at the Hanford Engineer Development Laboratory (operated by Westinghouse Hanford Company) and the initial tests are sponsored by EPRI. The objectives of the LACE program are: to demonstrate, at large-scale, inherent radioactive aerosol retention behavior for postulated high consequence LWR accident situations; and to provide a data base to be used for aerosol behavior . Test results from the first phase of the LACE program are presented and discussed. Three large-scale scoping tests, simulating a containment bypass accident sequence, demonstrated the extent of agglomeration and deposition of aerosols occurring in the pipe pathway and vented auxiliary building under realistic accident conditions. Parameters varied during the scoping tests were aerosol type and steam condensation

  8. The plane strain tests in the PROMETRA program

    International Nuclear Information System (INIS)

    Cazalis, B.; Desquines, J.; Carassou, S.; Le Jolu, T.; Bernaudat, C.

    2016-01-01

    A fuel cladding mechanical test, performed under conditions of plane strain deformation in the transverse direction of tube axis, was originally developed at Pennsylvania State University. It was decided to implement this original test within the PROMETRA program using the same experimental procedure and its optimization for a ring mechanical testing on plane strain conditions (PST tests) in hot cells laboratory. This paper presents a detailed description and an interpretation of the Plane Strain Tensile (PST) tests performed in the framework of the PROMETRA program on fresh and irradiated claddings. At first, the context of the PST tests is situated and the specificities of these tests implemented at CEA are justified. Indeed, a significant adjustment of the original experimental procedure is carried out in order to test the irradiated fuel cladding in the best possible conditions. Then, the tests results on fresh Zircaloy-4 and on irradiated Zircaloy-4, M5™ and ZIRLO ® specimens are gathered. The main analyses in support of these tests, such as metallographies, fractographic examinations and finite element simulations are detailed. Finally, a synthesis of the interpretation of the tests is proposed. The PST test seems only representative of plane strain fracture conditions when the test material is very ductile (fresh or high temperature or low hydride material like M5TM). However, it provides a relevant representation of the RIA rupture initiation which is observed in irradiated cladding resulting from hydride rim damage due to the strong irradiation of a fuel rod. - Highlights: • A plane strain mechanical test performed on fuel rod claddings is described. • The tests are performed in the framework of the French PROMETRA program. • Fresh Zircaloy-4 and irradiated Zircaloy-4, M5 and ZIRLO specimens are tested. • The main analyses in support of these tests are detailed. • A synthesis of the interpretation of the PST tests is proposed.

  9. The plane strain tests in the PROMETRA program

    Energy Technology Data Exchange (ETDEWEB)

    Cazalis, B., E-mail: bernard.cazalis@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSN-RES, F-13115 Saint-Paul Lez Durance BP3 (France); Desquines, J. [Institut de Radioprotection et de Sûreté Nucléaire, IRSN/PSN-RES, F-13115 Saint-Paul Lez Durance BP3 (France); Carassou, S.; Le Jolu, T. [Commissariat à l' Energie Atomique, CEA/DEN/DMN, F- 91191 Gif-sur-Yvette (France); Bernaudat, C. [Electricité de France, EDF/SEPTEN, F-69628 Villeurbanne (France)

    2016-04-15

    A fuel cladding mechanical test, performed under conditions of plane strain deformation in the transverse direction of tube axis, was originally developed at Pennsylvania State University. It was decided to implement this original test within the PROMETRA program using the same experimental procedure and its optimization for a ring mechanical testing on plane strain conditions (PST tests) in hot cells laboratory. This paper presents a detailed description and an interpretation of the Plane Strain Tensile (PST) tests performed in the framework of the PROMETRA program on fresh and irradiated claddings. At first, the context of the PST tests is situated and the specificities of these tests implemented at CEA are justified. Indeed, a significant adjustment of the original experimental procedure is carried out in order to test the irradiated fuel cladding in the best possible conditions. Then, the tests results on fresh Zircaloy-4 and on irradiated Zircaloy-4, M5™ and ZIRLO{sup ®} specimens are gathered. The main analyses in support of these tests, such as metallographies, fractographic examinations and finite element simulations are detailed. Finally, a synthesis of the interpretation of the tests is proposed. The PST test seems only representative of plane strain fracture conditions when the test material is very ductile (fresh or high temperature or low hydride material like M5TM). However, it provides a relevant representation of the RIA rupture initiation which is observed in irradiated cladding resulting from hydride rim damage due to the strong irradiation of a fuel rod. - Highlights: • A plane strain mechanical test performed on fuel rod claddings is described. • The tests are performed in the framework of the French PROMETRA program. • Fresh Zircaloy-4 and irradiated Zircaloy-4, M5 and ZIRLO specimens are tested. • The main analyses in support of these tests are detailed. • A synthesis of the interpretation of the PST tests is proposed.

  10. EBR-2 [Experimental Breeder Reactor-2] test programs

    International Nuclear Information System (INIS)

    Sackett, J.I.; Lehto, W.K.; Lindsay, R.W.; Planchon, H.P.; Lambert, J.D.B.; Hill, D.J.

    1990-01-01

    The Experimental Breeder Reactor-2 (EBR-2) is a sodium cooled power reactor supplying about 20 MWe to the Idaho National Engineering Laboratory (INEL) grid and, in addition, is the key component in the development of the Integral Fast Reactor (IFR). EBR-2's testing capability is extensive and has seen four major phases: (1) demonstration of LMFBR power plant feasibility, (2) irradiation testing for fuel and material development, (3) testing the off-normal performance of fuel and plant systems and (4) operation as the IFR prototype, developing and demonstrating the IFR technology associated with fuel and plant design. Specific programs being carried out in support of the IFR include advanced fuels and materials development, advanced control system development, plant diagnostics development and component testing. This paper discusses EBR-2 as the IFR prototype and the associated testing programs. 29 refs

  11. WIPP R and D in situ test program

    International Nuclear Information System (INIS)

    Tyler, L.D.

    1987-01-01

    The Waste Isolation Pilot Plant (WIPP) is a Department of Energy (DOE) RandD Facility for the purpose of developing the technology needed for the safe disposal of the United States' defense-related radioactive waste. The in situ test program focus is to provide the models and data to demonstrate the facility performance for isolation of waste at WIPP. The program is defined for the WIPP sealing system, thermal-structural interactions and waste package performance. A number of integrated large-scale underground tests have been operational since 1983 and are ongoing. The tests address the issues of both systems design and long-term isolation performance of the WIPP repository

  12. Cooperative field test program for wind systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bollmeier, W.S. II; Dodge, D.M.

    1992-03-01

    The objectives of the Federal Wind Energy Program, managed by the US Department of Energy (DOE), are (1) to assist industry and utilities in achieving a multi-regional US market penetration of wind systems, and (2) to establish the United States as the world leader in the development of advanced wind turbine technology. In 1984, the program conducted a series of planning workshops with representatives from the wind energy industry to obtain input on the Five-Year Research Plan then being prepared by DOE. One specific suggestion that came out of these meetings was that the federal program should conduct cooperative research tests with industry to enhance the technology transfer process. It was also felt that the active involvement of industry in DOE-funded research would improve the state of the art of wind turbine technology. DOE established the Cooperative Field Test Program (CFTP) in response to that suggestion. This program was one of the first in DOE to feature joint industry-government research test teams working toward common objectives.

  13. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment; Desenvolvimento de um dispositivo artesanal para os testes de colimação e alinhamento do raio central em equipamentos médicos de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S., E-mail: elizabethberbr@live.com [Universidade José de Souza Herdy (UNINGRANRIO), Nova Iguaçu, RJ (Brazil)

    2017-07-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden.

  14. Characterization of test specimens produced in reduced size for X-ray microtomography (µ-CT tests

    Directory of Open Access Journals (Sweden)

    E. E. BERNARDES

    Full Text Available Abstract The need to use reduced sample sizes, in order to attain improved spatial resolution in (µ-CT tests applied in Portland cement composites, makes researchers perform the fractionation of materials to obtain samples with dimensions compatible with the capacity of the scanning equipment, which might cause alterations in the microstructure under analysis. Therefore, a test specimen (TS with dimensions compatible with the scanning capacity of a microtomography system that operates with an X-ray tube and voltage ranging from 20 to 100 kV was proposed. Axial compression strength tests were made and their total porosity was assessed by an apparent density and solid fraction density ratio, which were obtained by means of mercury and helium pycnometry and µ-CT technique, respectively. The adoption of that TS has shown to be viable for providing a sample with a higher level of representation.

  15. The design and test of ellipsoidal glass capillaries as condensers for X-ray microscope

    International Nuclear Information System (INIS)

    Tian Jinping; Li Wenjie; Chen Jie; Liu Gang; Xiong Ying; Liu Longhua; Huang Xinlong; Tian Yangchao

    2008-01-01

    A high resolution X-ray microscope endstation was constructed on a wiggler beamline at the National Synchrotron Radiation Laboratory (NSRL). Parameters of the ellipsoidal glass capillaries as condensers were calculated and designed based on the illumination requests in the X-ray microscope system. Performance of the ellipsoidal glass capillaries was tested. The results indicate that the beam size agrees with the designed parameters and focus efficiencies of the ellipsoidal glass capillary condensers are better than 85%. (authors)

  16. Large-Scale Seismic Test Program at Hualien, Taiwan

    International Nuclear Information System (INIS)

    Tang, H.T.; Graves, H.L.; Yeh, Y.S.

    1991-01-01

    The Large-Scale Seismic Test (LSST) Program at Hualien, Taiwan, is a follow-on to the soil-structure interaction (SSI) experiments at Lotung, Taiwan. The planned SSI studies will be performed at a stiff soil site in Hualien, Taiwan, that historically has had slightly more destructive earthquakes in the past than Lotung. The objectives of the LSST project is as follows: To obtain earthquake-induced SSI data at a stiff soil site having similar prototypical nuclear power plant soil conditions. To confirm the findings and methodologies validated against the Lotung soft soil SSI data for prototypical plant condition applications. To further validate the technical basis of realistic SSI analysis approaches. To further support the resolution of USI A-40 Seismic Design Criteria issue. These objectives will be accomplished through an integrated and carefully planned experimental program consisting of: soil characterization, test model design and field construction, instrumentation layout and deployment, in-situ geophysical information collection, forced vibration test, and synthesis of results and findings. The LSST is a joint effort among many interested parties. EPRI and Taipower are the organizers of the program and have the lead in planning and managing the program

  17. Precise tests of x-ray scattering theories in the Compton regime

    International Nuclear Information System (INIS)

    Dunford, R. W.; Gemmell, D. S.; Kanter, E. P.; Kraessig, B.; Southworth, S. H.; Young, L.

    1999-01-01

    The authors report two experiments intended to test the accuracy of state-of-the-art theoretical predictions for x-ray scattering from low-Z atoms. The first one deals with the differential x-ray scattering cross sections in Ne and He from 11-22 keV and the Ne Compton-to-Rayleigh scattering ratio in this energy range. It was found that, in order to be consistent with the experimental results, an accurate description at low Z must include nonlocal exchange, electron correlation, and dynamic effects. The second experiment concerns the ratio of helium double-to-single ionization for Compton scattering in the 8-28 keV energy range where published experimental and theoretical results so far fail to give a consistent picture. The progress of the experiment and the data analysis is reported

  18. Nondestructive testing diagnosis for corrosion and welding by means of hydrostatic test and gamma ray tomography

    International Nuclear Information System (INIS)

    Moura, Alex E.; Dantas, Carlos C.; Nery, Marcelo S.; Barbosa, Jose Maria A.; Rolim, Tiago L.; Melo, Silvio B.; Lima, Emerson A.O.

    2013-01-01

    Diagnoses of light and severe corrosion process in steel tubes are carried out and results are presented. The material discontinuity in metallic pieces was investigated and signals from gamma source detection shown defect present or no defect present. Samples taken from street illumination posts were placed in computerized gamma ray scan to investigate corrosion effect. Scanning at three angles 0 deg, 60 deg and 120 deg degrees with five repetitions provide data set sufficient to a statistical analysis. Samples taken from small diameter steel tubes with light corrosion were analyzed too. Comparing corrosion-free samples detection of transmission gamma ray shows that along with diameter reduction a random density distribution takes place with severe corrosive process. The asymmetry induced in sample density provided to be effective for diagnosis of light corrosion by means of straight-line slope obtained in gamma profile. Structural integrity of steel pipes affected by welding process and defect propagation due to Hydrostatic Testing - HT was simulated by numerical finite element method and data comparison with experimental gamma tomography was carried out. Samples of pipes with preexisting defect on the welding region were submitted to hydrostatic tests over working pressure and a correlation between defect degree and structural resistance was evaluated. (author)

  19. Spillover effects of HIV testing policies: changes in HIV testing guidelines and HCV testing practices in drug treatment programs in the United States

    Directory of Open Access Journals (Sweden)

    Jemima A. Frimpong

    2016-07-01

    Full Text Available Abstract Background To examine the extent to which state adoption of the Centers for Disease Control and Prevention (CDC 2006 revisions to adult and adolescent HIV testing guidelines is associated with availability of other important prevention and medical services. We hypothesized that in states where the pretest counseling requirement for HIV testing was dropped from state legislation, substance use disorder treatment programs would have higher availability of HCV testing services than in states that had maintained this requirement. Methods We analyzed a nationally representative sample of 383 opioid treatment programs from the 2005 and 2011 National Drug Abuse Treatment System Survey (NDATSS. Data were collected from program directors and clinical supervisors through telephone surveys. Multivariate logistic regression models were used to measure associations between state adoption of CDC recommended guidelines for HIV pretest counseling and availability of HCV testing services. Results The effects of HIV testing legislative changes on HCV testing practices varied by type of opioid treatment program. In states that had removed the requirement for HIV pretest counseling, buprenorphine-only programs were more likely to offer HCV testing to their patients. The positive spillover effect of HIV pretest counseling policies, however, did not extend to methadone programs and did not translate into increased availability of on-site HCV testing in either program type. Conclusions Our findings highlight potential positive spillover effects of HIV testing policies on HCV testing practices. They also suggest that maximizing the benefits of HIV policies may require other initiatives, including resources and programmatic efforts that support systematic integration with other services and effective implementation.

  20. The performance test of anti-scattering x-ray grid with inclined shielding material by MCNP code simulation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jun Woo; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2016-06-15

    The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination.

  1. GAUSS VII: a computer program for the analysis of #betta#-ray spectra from Ge semiconductor spectrometers

    International Nuclear Information System (INIS)

    McCullagh, C.M.; Helmer, R.G.

    1982-10-01

    A description is given of a computer program, GAUSS VII, which has been written to determine #betta#-ray spectra from Ge semiconductor spectrometers. The preliminary portions of the program can determine the energy and width calibration equations, loacte individual peaks and define peak regions that are significantly above the local spectral background. The user may edit these lists of peaks and regions. Each peak region is fitted with one or more components in which the peaks are represented by a Gaussian function or a Gaussian with one or two additive exponential tails on the low-energy side and one on the high-energy side. A step-like background function can be used with each component. The program will automatically recycle to add one or more components to a region if needed to improve the fit. The #betta#-ray energies and intensities are computed from resulting Gaussian positions and peak areas. To allow the user to determine the best results, the results from the analyses for each region with different numbers of components can be printed and line-printer plots of the fits to the data can be made. The quality of the results depends primarily on the ability of the program to define a good spectral region for each analysis and the ability to recycle to determine the proper number of components

  2. 47 CFR 73.1620 - Program tests.

    Science.gov (United States)

    2010-10-01

    ... integration of ownership and management and diversification of the media of mass communciation contained in... 47 Telecommunication 4 2010-10-01 2010-10-01 false Program tests. 73.1620 Section 73.1620 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES...

  3. Testing gravitational parity violation with coincident gravitational waves and short gamma-ray bursts

    International Nuclear Information System (INIS)

    Yunes, Nicolas; O'Shaughnessy, Richard; Owen, Benjamin J.; Alexander, Stephon

    2010-01-01

    Gravitational parity violation is a possibility motivated by particle physics, string theory, and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest itself as a discrepancy between these two distance measurements. We exemplify such a test by considering one specific effective theory that leads to such gravitational parity violation, Chern-Simons gravity. We show that the advanced LIGO-Virgo network and all-sky gamma-ray telescopes can be sensitive to the propagating sector of Chern-Simons gravitational parity violation to a level roughly 2 orders of magnitude better than current stationary constraints from the LAGEOS satellites.

  4. X-ray safety at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Gutierrez, J.A.

    1986-11-01

    An organized and structured safety program for x-ray generating devices was initiated in October, 1979. An X-ray Device Control Office was established to manage the program that currently oversees the activities of 201 x-ray generating devices and to provide SOP reviews, perform shielding calculations, and provide training for both the operators and health physics x-ray device surveyors. The new program also establishes controls for procurement of new equipment, requires the writing of Standard Operating Procedures, requires training for operators and provides routine and non-routine safety inspections of x-ray generating devices. Prior to this program going into effect, the Laboratory had recorded nine documented x-ray related exposure accidents. Since then, there have been none. Program elements and experiences of interest to other x-ray device users are discussed. 3 refs

  5. Advanced Utility Mercury-Sorbent Field-Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Landreth

    2007-12-31

    This report summarizes the work conducted from September 1, 2003 through December 31, 2007 on the project entitled Advanced Utility Mercury-Sorbent Field-Testing Program. The project covers the testing at the Detroit Edison St. Clair Plant and the Duke Power Cliffside and Buck Stations. The St. Clair Plant used a blend of subbituminous and bituminous coal and controlled the particulate emissions by means of a cold-side ESP. The Duke Power Stations used bituminous coals and controlled their particulate emissions by means of hot-side ESPs. The testing at the Detroit Edison St. Clair Plant demonstrated that mercury sorbents could be used to achieve high mercury removal rates with low injection rates at facilities that burn subbituminous coal. A mercury removal rate of 94% was achieved at an injection rate of 3 lb/MMacf over the thirty day long-term test. Prior to this test, it was believed that the mercury in flue gas of this type would be the most difficult to capture. This is not the case. The testing at the two Duke Power Stations proved that carbon- based mercury sorbents can be used to control the mercury emissions from boilers with hot-side ESPs. It was known that plain PACs did not have any mercury capacity at elevated temperatures but that brominated B-PAC did. The mercury removal rate varies with the operation but it appears that mercury removal rates equal to or greater than 50% are achievable in facilities equipped with hot-side ESPs. As part of the program, both sorbent injection equipment and sorbent production equipment was acquired and operated. This equipment performed very well during this program. In addition, mercury instruments were acquired for this program. These instruments worked well in the flue gas at the St. Clair Plant but not as well in the flue gas at the Duke Power Stations. It is believed that the difference in the amount of oxidized mercury, more at Duke Power, was the difference in instrument performance. Much of the equipment was

  6. Nevada Test Site Radiation Protection Program

    Energy Technology Data Exchange (ETDEWEB)

    Radiological Control Managers' Council, Nevada Test Site

    2007-08-09

    Title 10 Code of Federal Regulations (CFR) 835, 'Occupational Radiation Protection', establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (onsite or offsite) DOE National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration offsite projects.

  7. Program Helps Design Tests Of Developmental Software

    Science.gov (United States)

    Hops, Jonathan

    1994-01-01

    Computer program called "A Formal Test Representation Language and Tool for Functional Test Designs" (TRL) provides automatic software tool and formal language used to implement category-partition method and produce specification of test cases in testing phase of development of software. Category-partition method useful in defining input, outputs, and purpose of test-design phase of development and combines benefits of choosing normal cases having error-exposing properties. Traceability maintained quite easily by creating test design for each objective in test plan. Effort to transform test cases into procedures simplified by use of automatic software tool to create cases based on test design. Method enables rapid elimination of undesired test cases from consideration and facilitates review of test designs by peer groups. Written in C language.

  8. Quality assurance in the nuclear test program

    International Nuclear Information System (INIS)

    Shearer, J.N.

    1979-01-01

    In February 1979 Test Program laid the ground work for a new quality assurance structure. The new approach was based on the findings and recommendations of the Ad Hoc QA Program Review panel, which are summarized in this report. The new structure places the responsibility for quality assurance in the hands of the line organizations, both in the programmatic and functional elements of the LLL matrix

  9. 75 FR 22809 - Mandatory Guidelines for Federal Workplace Drug Testing Programs

    Science.gov (United States)

    2010-04-30

    ... time for related training in Federal and federally-regulated workplace drug testing programs and will... related training in Federal and federally-regulated workplace drug testing programs, including HHS... DEPARTMENT OF HEALTH AND HUMAN SERVICES Mandatory Guidelines for Federal Workplace Drug Testing...

  10. Adaptive Test Selection for Factorization-based Surrogate Fitness in Genetic Programming

    Directory of Open Access Journals (Sweden)

    Krawiec Krzysztof

    2017-12-01

    Full Text Available Genetic programming (GP is a variant of evolutionary algorithm where the entities undergoing simulated evolution are computer programs. A fitness function in GP is usually based on a set of tests, each of which defines the desired output a correct program should return for an exemplary input. The outcomes of interactions between programs and tests in GP can be represented as an interaction matrix, with rows corresponding to programs in the current population and columns corresponding to tests. In previous work, we proposed SFIMX, a method that performs only a fraction of interactions and employs non-negative matrix factorization to estimate the outcomes of remaining ones, shortening GP’s runtime. In this paper, we build upon that work and propose three extensions of SFIMX, in which the subset of tests drawn to perform interactions is selected with respect to test difficulty. The conducted experiment indicates that the proposed extensions surpass the original SFIMX on a suite of discrete GP benchmarks.

  11. Minimum Leakage Condenser Test Program

    International Nuclear Information System (INIS)

    1978-05-01

    This report presents the results and analysis of tests performed on four critical areas of large surface condensers: the tubes, tubesheets, tube/tubesheet joints and the water chambers. Significant changes in operation, service duty and the reliability considerations require that certain existing design criteria be verified and that improved design features be developed. The four critical areas were treated analytically and experimentally. The ANSYS finite element computer program was the basic analytical method and strain gages were used for obtaining experimental data. The results of test and analytical data are compared and recommendations made regarding potential improvement in condenser design features and analytical techniques

  12. Patient dose evaluations from medical X-ray exposure in Italy: an analysis of next data

    International Nuclear Information System (INIS)

    Marchetti, A.; Paganini, F.M.; Susanna, A.

    1980-01-01

    NEXT (Nationwide Evaluation of X-ray Trends) is a program for the evaluation of patient exposure in X-ray diagnostic tests. The program is aimed at reducing patient exposure by pin-pointing poor radiological techniques and improving them. CNEN (Comitato Nazionale per l'Energia Nucleare) and ISS (Istituto Superiore di Sanita) have been developing such a program in Italy since 1976. Up to now two regional administrations applied the method and regional operators collected the needed data in all the medical institutions in their areas. The results show a wide spread of values for all the parameters studied in the 12 X-ray projections selected. Gonad dose and skin entrance exposure were found to be spread over a range up to about two orders of magnitude. (H.K.)

  13. The importance of pre-planning for large hydrostatic test programs

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Andrew Keith [WorleyParsons Calgary, Calgary, AB (Canada); Wong, Everett Clementi [Enbridge Pipelines Inc., Edmonton, AB (Canada)

    2010-07-01

    During the design phase of a pipeline project, large hydrostatic test programs are required to locate and secure water sources. Many companies complete hydrostatic test planning through high level desktop analysis, however this technique can result in important unplanned costs and schedule delays. The aim of this paper is to assess the cost benefits of pre-planning large hydrostatic test programs versus the costs of unplanned delays in the execution of hydrostatic testing. This comparison was based on the successful application of pre-planning of 57 mainline hydrostatic tests in the construction of the Line 4 Extension and Alberta Clipper Expansion oil pipelines by Enbridge Pipelines Inc. Results showed that costs of delays and uncertainty during construction far outweigh the costs of pre-planning. This study highlighted that pre-planning for large hydrostatic test programs should be carried out in the execution of large pipeline projects to ensure success.

  14. A phantom test of proton-induced dual-energy X-ray angiography using iodinated contrast media

    International Nuclear Information System (INIS)

    Oguri, Y.; Hasegawa, J.; Ogawa, M.; Kaneko, J.; Sasa, K.

    2007-01-01

    Characteristic-line radiation from heavy metal targets bombarded by MeV proton beams has been tested as an X-ray source for dual-energy K-edge subtraction imaging for human angiography (blood vessel imaging) based on iodinated contrast media. To utilize the strong absorption by iodine (Z=53) at its K-absorption edge (33.2 keV), we used K α -line of La (lanthanum, Z=57) at 33.4 keV. As a reference, also K α X emission of Sn (tin, Z=50) at 25.2 keV was employed. Metallic plates of La and Sn were irradiated by 7-MeV protons to produce these characteristic X-rays. Energy-subtraction method was tested using Lucite phantoms which contain aqueous solutions of KI (potassium iodide) with different concentrations. Also Ca(H 2 PO 4 ) 2 powder was stuffed in these phantoms to simulate bones. The transmission images of the phantoms were recorded on imaging plates. During the exposure, the energy spectra of the X-rays were monitored by a CdTe detector. We found that the contrast of images of iodide solutions taken with La X-rays was higher than that with Sn X-rays. Also the energy subtraction procedure was successfully applied to reduce the graphical noise due to the bones and inhomogeneity of the soft tissue. However, to apply the present method to actual clinical use, the X-ray intensity must be increased by several orders of magnitude. Also the transmission of the 'lower-energy' photons has to be a few orders higher for imaging of objects as thick as human chest. (author)

  15. History of ground motion programs at the Nevada Test Site

    International Nuclear Information System (INIS)

    Banister, J.R.

    1984-01-01

    Some measurements were made in the atmospheric testing era, but the study of ground motion from nuclear tests became of wider interest after the instigation of underground testing. The ground motion generated by underground nuclear test has been investigated for a number of reasons including understanding basic phenomena, operational and safety concerns, yield determination, stimulation of earthquake concerns, and developing methods to aid in treaty verifications. This history of ground motion programs will include discussing early studies, high yield programs, Peaceful Nuclear Explosions tests, and some more recent developments. 6 references, 10 figures

  16. Standard test method for determining the effective elastic parameter for X-ray diffraction measurements of residual stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a procedure for experimentally determining the effective elastic parameter, Eeff, for the evaluation of residual and applied stresses by X-ray diffraction techniques. The effective elastic parameter relates macroscopic stress to the strain measured in a particular crystallographic direction in polycrystalline samples. Eeff should not be confused with E, the modulus of elasticity. Rather, it is nominally equivalent to E/(1 + ν) for the particular crystallographic direction, where ν is Poisson's ratio. The effective elastic parameter is influenced by elastic anisotropy and preferred orientation of the sample material. 1.2 This test method is applicable to all X-ray diffraction instruments intended for measurements of macroscopic residual stress that use measurements of the positions of the diffraction peaks in the high back-reflection region to determine changes in lattice spacing. 1.3 This test method is applicable to all X-ray diffraction techniques for residual stress measurem...

  17. Optimization of a readout board for mass assembly and light yield measurements with a cosmic ray test stand

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Phi [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik (Germany); Collaboration: CALICE-D-Collaboration

    2016-07-01

    We have built a readout board prototype, equipped with SiPMs, scintillators and readout electronics for an highly granular calorimeter. The design was optimized for mass assembly due to about 8 million channels in the final detector. The prototype showed good performance in several test beams and in a cosmic ray test stand, which was built to characterize the MIP response of these kinds of boards. We show an overview of the cosmic ray test stand and measurement results for the readout board and plans for an improved 2nd generation prototype.

  18. Wide-area phase-contrast X-ray imaging using large X-ray interferometers

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi E-mail: momose@exp.t.u-tokyo.ac.jp; Takeda, Tohoru; Yoneyama, Akio; Koyama, Ichiro; Itai, Yuji

    2001-07-21

    Large X-ray interferometers are developed for phase-contrast X-ray imaging aiming at medical applications. A monolithic X-ray interferometer and a separate one are studied, and currently a 25 mmx20 mm view area can be generated. This paper describes the strategy of our research program and some recent developments.

  19. Wide-area phase-contrast X-ray imaging using large X-ray interferometers

    Science.gov (United States)

    Momose, Atsushi; Takeda, Tohoru; Yoneyama, Akio; Koyama, Ichiro; Itai, Yuji

    2001-07-01

    Large X-ray interferometers are developed for phase-contrast X-ray imaging aiming at medical applications. A monolithic X-ray interferometer and a separate one are studied, and currently a 25 mm×20 mm view area can be generated. This paper describes the strategy of our research program and some recent developments.

  20. Standard test method for quantitative determination of americium 241 in plutonium by Gamma-Ray spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers the quantitative determination of americium 241 by gamma-ray spectrometry in plutonium nitrate solution samples that do not contain significant amounts of radioactive fission products or other high specific activity gamma-ray emitters. 1.2 This test method can be used to determine the americium 241 in samples of plutonium metal, oxide and other solid forms, when the solid is appropriately sampled and dissolved. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. 175 Years of Linear Programming

    Indian Academy of Sciences (India)

    polynomial-time solvability of linear programming, that is, testing if a polyhedron Q E ~ ... Q is rational, i.e. all extreme points and rays of Q are ra- tional vectors or ..... rithrll terminates with an interior solution, a post-processing step is usually ...

  2. Environmental test program for superconducting materials and devices

    Science.gov (United States)

    Haertling, Gene; Randolph, Henry; Hsi, Chi-Shiung; Verbelyi, Darren

    1991-01-01

    This report is divided into two parts. The first dealing with work involved with Clemson University and the second with the results from Westinghouse/Savannah River. Both areas of work involved low noise, low thermal conductivity superconducting grounding links used in the NASA-sponsored Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) Project. Clemson prepared the links from YBa2Cu3O(7-x) superconductor tape that was mounted on a printed circuit board and encapsulated with epoxy resin. The Clemson program includes temperature vs. resistance, liquid nitrogen immersion, water immersion, thermal cycling, humidity, and radiation testing. The evaluation of the links under a long term environmental test program is described. The Savannah River program includes gamma irradiation, vibration, and long-term evaluation. The progress made in these evaluations is discussed.

  3. The joint EC/EPA mid-Connecticut test program

    International Nuclear Information System (INIS)

    Kilgroe, J.D.; Brna, T.G.

    1991-01-01

    In early 1989, Environment Canada and the U.S. Environmental Protection Agency sponsored a comprehensive test program on a refuse-derived fuel (RDF) unit of the Mid-Connecticut facility in Hartford. The program, conducted in cooperation with the Connecticut Resource Recovery Authority (CRRA), the facility's operator, included characterization and performance test phases. The results of the characterization tests were used in defining both the combustion and flue gas cleaning system operating conditions for the performance tests. The results of the performance tests are emphasized in this paper and are summarized in three parts. First, the combustion tests results will be addressed and related to good combustion practice for RDF combustors. Then, the performance of the lime spray dryer absorber/fabric filter system in controlling acid gas (hydrogen chloride, sulfur dioxide), trace organic [polychlorinated dibenzodioxin (PCDD) and polychlorinated dibenzofuran (PCDF)], trace metal [arsenic (as), cadmium (Cd), chromium (Cr), lead (Pb), mercury (Hg), nickel (Ni), and zinc (Zn)], and particulate matter (PM) emissions will be discussed. Finally, the results of ash/residue analyses will be presented

  4. A program for the derivation of crystal unit cell parameters from X-ray powder diffraction measurements

    International Nuclear Information System (INIS)

    Ferguson, I.F.; Rogerson, A.H.

    1984-01-01

    The program, FIRESTAR, determines the dimensions of a crystallographic unit cell from a set of X-ray powder diffraction measurements corresponding to a set of Bragg reflections, provided that the crystal system applicable is known and the Bragg reflections have been indexed. The program includes a range of possible extrapolation functions, and the data may be weighted. Provision is made for detecting and rejecting a single 'bad' measurement, and then rejecting measurements which lie outside an error limit set in the input data. (orig.)

  5. LISA Pathfinder test-mass charging during galactic cosmic-ray flux short-term variations

    Science.gov (United States)

    Grimani, C.; Fabi, M.; Lobo, A.; Mateos, I.; Telloni, D.

    2015-02-01

    Metal free-floating test masses aboard the future interferometers devoted to gravitational wave detection in space are charged by galactic and solar cosmic rays with energies \\gt 100 MeV/n. This process represents one of the main sources of noise in the lowest frequency band (\\lt 10-3 Hz) of these experiments. We study here the charging of the LISA Pathfinder (LISA-PF) gold-platinum test masses due to galactic cosmic-ray (GCR) protons and helium nuclei with the Fluka Monte Carlo toolkit. Projections of the energy spectra of GCRs during the LISA-PF operations in 2015 are considered. This work was carried out on the basis of the solar activity level and solar polarity epoch expected for LISA-PF. The effects of GCR short-term variations are evaluated here for the first time. Classical Forbush decreases, GCR variations induced by the Sun rotation, and fluctuations in the LISA-PF frequency bandwidth are discussed.

  6. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  7. How My Program Passed the Turing Test

    Science.gov (United States)

    Humphrys, Mark

    In 1989, the author put an ELIZA-like chatbot on the Internet. The conversations this program had can be seen - depending on how one defines the rules (and how seriously one takes the idea of the test itself) - as a passing of the Turing Test. This is the first time this event has been properly written. This chatbot succeeded due to profanity, relentless aggression, prurient queries about the user, and implying that they were a liar when they responded. The element of surprise was also crucial. Most chatbots exist in an environment where people expectto find some bots among the humans. Not this one. What was also novel was the onlineelement. This was certainly one of the first AI programs online. It seems to have been the first (a) AI real-time chat program, which (b) had the element of surprise, and (c) was on the Internet. We conclude with some speculation that the future of all of AI is on the Internet, and a description of the "World- Wide-Mind" project that aims to bring this about.

  8. Model-based automated testing of critical PLC programs.

    CERN Document Server

    Fernández Adiego, B; Tournier, J-C; González Suárez, V M; Bliudze, S

    2014-01-01

    Testing of critical PLC (Programmable Logic Controller) programs remains a challenging task for control system engineers as it can rarely be automated. This paper proposes a model based approach which uses the BIP (Behavior, Interactions and Priorities) framework to perform automated testing of PLC programs developed with the UNICOS (UNified Industrial COntrol System) framework. This paper defines the translation procedure and rules from UNICOS to BIP which can be fully automated in order to hide the complexity of the underlying model from the control engineers. The approach is illustrated and validated through the study of a water treatment process.

  9. High Performance Computing Modernization Program Kerberos Throughput Test Report

    Science.gov (United States)

    2017-10-26

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/5524--17-9751 High Performance Computing Modernization Program Kerberos Throughput Test ...NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2. REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 6. AUTHOR(S) 8. PERFORMING...PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT High Performance Computing Modernization Program Kerberos Throughput Test Report Daniel G. Gdula* and

  10. International collaboration on CESR-TA program

    International Nuclear Information System (INIS)

    Flanagan, John; Suetsugu, Yusuke

    2009-01-01

    An international collaboration on the CESR-TA (Cornell Electron Storage Ring-Test Accelerator) program, which is a program to investigate electron cloud instability (ECI) issues in the positron damping ring of the ILC (International Linear-Collider), is currently underway a Cornell University, KEK is supporting the program through the development of an X-ray beam profile monitor system to measure the extremely small beam size, and through the development of clearing electrodes to mitigate the ECI. (author)

  11. Au-coated X-ray Anti-scattering Grid Performance Test by MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Bae, JunWoo; Yoo, Dong Han; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    It is required to protect individual against the dangers of ionizing radiation from medical exposure. And increasing of resolution for x-ray radiography tools can give radiation protectoral benefits. Because the image device has higher resolution in same energy source, it requires low energy level source and it can reduce individual dose. The anti-scattering grid is sub-device that is attached in front of detector (direction of source). It is square lattice shape generally. It is composed of penetration parts and shielding parts. Penetration part is generally air (the void) and in some studies it uses wood or aluminum. Shielding part is composed of various materials such as lead or copper. In this study, it is focused on the gold as one of X-ray grid materials, where gold is generally known as excellent shielding material and the performance test on the gold coated anti-scattering grid is carried out by MCNP simulation. X-ray grid was simulated by using MCNP code and its performance was investigated. It was understood that glass based and Au-coated grid could lessen the scattered photons more where the reduction was about two third. In further study, geometry optimization or material selection will be conducted by MCNP simulation for giving benefits to design proper grid for various instruments.

  12. Dr TIM: Ray-tracer TIM, with additional specialist scientific capabilities

    Science.gov (United States)

    Oxburgh, Stephen; Tyc, Tomáš; Courtial, Johannes

    2014-03-01

    We describe several extensions to TIM, a raytracing program for ray-optics research. These include relativistic raytracing; simulation of the external appearance of Eaton lenses, Luneburg lenses and generalised focusing gradient-index lens (GGRIN) lenses, which are types of perfect imaging devices; raytracing through interfaces between spaces with different optical metrics; and refraction with generalised confocal lenslet arrays, which are particularly versatile METATOYs. Catalogue identifier: AEKY_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEKY_v2_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licencing provisions: GNU General Public License No. of lines in distributed program, including test data, etc.: 106905 No. of bytes in distributed program, including test data, etc.: 6327715 Distribution format: tar.gz Programming language: Java. Computer: Any computer capable of running the Java Virtual Machine (JVM) 1.6. Operating system: Any, developed under Mac OS X Version 10.6 and 10.8.3. RAM: Typically 130 MB (interactive version running under Mac OS X Version 10.8.3) Classification: 14, 18. Catalogue identifier of previous version: AEKY_v1_0 Journal reference of previous version: Comput. Phys. Comm. 183(2012)711 External routines: JAMA [1] (source code included) Does the new version supersede the previous version?: Yes Nature of problem: Visualisation of scenes that include scene objects that create wave-optically forbidden light-ray fields. Solution method: Ray tracing. Reasons for new version: Significant extension of the capabilities (see Summary of revisions), as demanded by our research. Summary of revisions: Added capabilities include the simulation of different types of camera moving at relativistic speeds relative to the scene; visualisation of the external appearance of generalised focusing gradient-index (GGRIN) lenses, including Maxwell fisheye, Eaton and Luneburg lenses; calculation of

  13. Testing the Structure of Hydrological Models using Genetic Programming

    Science.gov (United States)

    Selle, B.; Muttil, N.

    2009-04-01

    Genetic Programming is able to systematically explore many alternative model structures of different complexity from available input and response data. We hypothesised that genetic programming can be used to test the structure hydrological models and to identify dominant processes in hydrological systems. To test this, genetic programming was used to analyse a data set from a lysimeter experiment in southeastern Australia. The lysimeter experiment was conducted to quantify the deep percolation response under surface irrigated pasture to different soil types, water table depths and water ponding times during surface irrigation. Using genetic programming, a simple model of deep percolation was consistently evolved in multiple model runs. This simple and interpretable model confirmed the dominant process contributing to deep percolation represented in a conceptual model that was published earlier. Thus, this study shows that genetic programming can be used to evaluate the structure of hydrological models and to gain insight about the dominant processes in hydrological systems.

  14. X-ray diagnostics in the laser-initiated fusion program

    International Nuclear Information System (INIS)

    Godwin, R.P.

    1975-08-01

    The high-density and high-temperature plasma conditions required for successful laser-initiated fusion make x-ray diagnostics a valuable tool in this exciting field. Measurements of the hard x-ray continuum emitted from laser targets provide insight into the complex laser-plasma coupling physics and the consequent energy transport through the bremsstrahlung signature of energetic electrons. X-ray techniques are important in the selection and assay of microballoon targets for current compression experiments. X-ray imaging experiments and diffraction spectroscopy of highly stripped atoms can provide information upon the symmetry, density and temperature of laser targets. Extremely high temporal and spatial resolution may be required for definitive diagnostic information on compressed targets. While laser-produced plasmas are interesting as possible intense x-ray sources and as a possible means of achieving x-ray lasing, those topics are outside the scope of this review. (auth)

  15. Preliminary irradiation test results from the Yankee Atomic Electric Company reactor vessel test irradiation program

    International Nuclear Information System (INIS)

    Biemiller, E.C.; Fyfitch, S.; Campbell, C.A.

    1993-01-01

    The Yankee Atomic Electric Company test irradiation program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials and to remove uncertainties in the analysis of existing irradiation data on the Yankee Rowe reactor vessel steel. Plate materials each containing 0.24 w/o copper, but different nickel contents at 0.63 w/o and 0.19 w/o, were heat treated to simulate the Yankee vessel heat treatment (austenitized at 1800 deg F) and to simulate Regulatory Guide 1.99 database materials (austenitized at 1600 deg. F). These heat treatments produced different microstructures so the effect of microstructure on irradiation damage sensitivity could be tested. Because the nickel content of the test plates varied and the copper level was constant, the effect of nickel on irradiation embrittlement was also tested. Correlation monitor material, HSST-02, was included in the program to benchmark the Ford Nuclear Reactor (U. of Michigan Test Reactor) which had never been used for this type of irradiation program. Materials taken from plate surface locations (vs. 1/4T) were included to test whether or not the improved toughness properties of the plate surface layer, resulting from the rapid quench, is maintained after irradiation. If the improved properties are maintained, pressurized thermal shock calculations could utilize this margin. Finally, for one experiment, irradiations were conducted at two irradiation temperatures (500 deg. F and 550 deg. F) to determine the effect of irradiation temperature on embrittlement. The preliminary results of the irradiation program show an increase in T 30 shift of 69 deg. F for a decrease in irradiation temperature of 50 deg. F. The results suggest that for nickel bearing steels, the superior toughness of plate surface material is maintained after irradiation and for the copper content tested, nickel had no apparent effect on irradiation response. No apparent microstructure

  16. The High Level Vibration Test Program

    International Nuclear Information System (INIS)

    Hofmayer, C.H.; Curreri, J.R.; Park, Y.J.; Kato, W.Y.; Kawakami, S.

    1989-01-01

    As part of cooperative agreements between the United States and Japan, tests have been performed on the seismic vibration table at the Tadotsu Engineering Laboratory of Nuclear Power Engineering Test Center (NUPEC) in Japan. The objective of the test program was to use the NUPEC vibration table to drive large diameter nuclear power piping to substantial plastic strain with an earthquake excitation and to compare the results with state-of-the-art analysis of the problem. The test model was designed by modifying the 1/2.5 scale model of the PWR primary coolant loop. Elastic and inelastic seismic response behavior of the test model was measured in a number of test runs with an increasing excitation input level up to the limit of the vibration table. In the maximum input condition, large dynamic plastic strains were obtained in the piping. Crack initiation was detected following the second maximum excitation run. The test model was subjected to a maximum acceleration well beyond what nuclear power plants are designed to withstand. This paper describes the overall plan, input motion development, test procedure, test results and comparisons with pre-test analysis. 4 refs., 16 figs., 2 tabs

  17. The High Level Vibration Test program

    International Nuclear Information System (INIS)

    Hofmayer, C.H.; Curreri, J.R.; Park, Y.J.; Kato, W.Y.; Kawakami, S.

    1990-01-01

    As part of cooperative agreements between the United States and Japan, tests have been performed on the seismic vibration table at the Tadotsu Engineering Laboratory of Nuclear Power Engineering Test Center (NUPEC) in Japan. The objective of the test program was to use the NUPEC vibration table to drive large diameter nuclear power piping to substantial plastic strain with an earthquake excitation and to compare the results with state-of-the-art analysis of the problem. The test model was designed by modifying the 1/2.5 scale model of the pressurized water reactor primary coolant loop. Elastic and inelastic seismic response behavior of the test model was measured in a number of test runs with an increasing excitation input level up to the limit of the vibration table. In the maximum input condition, large dynamic plastic strains were obtained in the piping. Crack initiation was detected following the second maximum excitation run. The test model was subjected to a maximum acceleration well beyond what nuclear power plants are designed to withstand. This paper describes the overall plan, input motion development, test procedure, test results and comparisons with pre-test analysis

  18. Application of a tandem ionization chamber in a quality control program of X-ray beams, radiotherapy level

    International Nuclear Information System (INIS)

    Yoshizumi, Maira T.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber, developed at the Instituto de Pesquisas Energeticas e Nucleares (IPEN), for X radiation beams, radiotherapy level, was applied into a quality control program of the Calibration Laboratory of IPEN. This ionization chamber is composed by two ionization chambers, with a volume of 0.6 cm 3 each one. Its inner plane-parallel electrodes and guard rings are made of different materials: one is made of aluminum and the other is made of graphite. Because of this difference in materials, the ionization chamber forms a tandem system. The relative response of the calibration factors of both sides of the chamber allows an easy verification of the X-ray beam qualities stability. The ionization chamber was submitted to some tests to verify the stability of its response: leakage current before and after exposure, repeatability and reproducibility. The performance of the ionization chamber was satisfactory. (author)

  19. Miniature gamma-ray camera for tumor localization

    International Nuclear Information System (INIS)

    Lund, J.C.; Olsen, R.W.; James, R.B.; Cross, E.

    1997-08-01

    The overall goal of this LDRD project was to develop technology for a miniature gamma-ray camera for use in nuclear medicine. The camera will meet a need of the medical community for an improved means to image radio-pharmaceuticals in the body. In addition, this technology-with only slight modifications-should prove useful in applications requiring the monitoring and verification of special nuclear materials (SNMs). Utilization of the good energy resolution of mercuric iodide and cadmium zinc telluride detectors provides a means for rejecting scattered gamma-rays and improving the isotopic selectivity in gamma-ray images. The first year of this project involved fabrication and testing of a monolithic mercuric iodide and cadmium zinc telluride detector arrays and appropriate collimators/apertures. The second year of the program involved integration of the front-end detector module, pulse processing electronics, computer, software, and display

  20. The emission of Gamma Ray Bursts as a test-bed for modified gravity

    Directory of Open Access Journals (Sweden)

    S. Capozziello

    2015-11-01

    Full Text Available The extreme physical conditions of Gamma Ray Bursts can constitute a useful observational laboratory to test theories of gravity where very high curvature regimes are involved. Here we propose a sort of curvature engine capable, in principle, of explaining the huge energy emission of Gamma Ray Bursts. Specifically, we investigate the emission of radiation by charged particles non-minimally coupled to the gravitational background where higher order curvature invariants are present. The coupling gives rise to an additional force inducing a non-geodesic motion of particles. This fact allows a strong emission of radiation by gravitationally accelerated particles. As we will show with some specific model, the energy emission is of the same order of magnitude of that characterizing the Gamma Ray Burst physics. Alternatively, strong curvature regimes can be considered as a natural mechanism for the generation of highly energetic astrophysical events. Possible applications to cosmology are discussed.

  1. Gamma-ray isotopic ratio measurements for the plutonium inventory verification program

    International Nuclear Information System (INIS)

    Lemming, J.F.; Haas, F.X.; Jarvis, J.Y.

    1976-01-01

    The Plutonium Inventory Verification Program at Mound Laboratory provides a nondestructive means of assaying bulk plutonium-bearing material. The assay is performed by combining the calorimetrically determined heat output of the sample and the relative abundances of the heat-producing isotopes. This report describes the method used for the nondestructive determination of plutonium-238, -240, -241 and americium-241 relative to plutonium-239 using gamma-ray spectroscopy for 93 percent plutonium-239 material. Comparison of chemical data on aliquots of samples to the nondestructive data shows accuracies of +-7 percent for 238 Pu/ 239 Pu, +-15 percent for 240 Pu/ 239 Pu, +- 3 percent for 241 Pu/ 239 Pu, and +-7 percent for 241 Am/ 239 Pu

  2. An alternative approach to contrast-detail testing of X-ray image intensifier systems

    International Nuclear Information System (INIS)

    Kotre, C.J.; Marshall, N.W.; Faulkner, K.

    1992-01-01

    The difficulties of making the results of threshold contrast-detail diameter tests on X-ray image intensifier systems consistent with published performance standards are discussed. The current approach to contrast-detail testing is described and an alternative method intended to give greater consistency for all image intensifier input field diameters proposed. The current and alternative test conditions are compared on two image intensifier systems. The results obtained show that the contrast-detail curves for image intensifier systems with a wide range of input field diameters can be effectively normalized to be directly comparable to a common reference standard by applying the proposed alternative test conditions. The implications of this result on the interpretation of the contrast-detail test are discussed. (author)

  3. Performance-based improvement of the leakage rate test program for the reactor containment of HTTR. Adoption of revised test programs containing 'Type A, Type B and Type C tests'

    International Nuclear Information System (INIS)

    Kondo, Masaaki; Emori, Koichi; Sekita, Kenji; Furusawa, Takayuki; Hayakawa, Masato; Kozawa, Takayuki; Aono, Tetsuya; Kuroha, Misao; Ouchi, Hiroshi; Kimishima, Satoru

    2008-10-01

    The reactor containment of HTTR is periodically tested to confirm leak-tight integrity by conducting overall integrated leakage rate tests, so-called 'Type A tests,' in accordance with a standard testing method provided in Japan Electric Association Code (JEAC) 4203. 'Type A test' is identified as a basic one for measuring whole leakage rates for reactor containments, it takes, however, much of cost and time of preparation, implementation and restoration of itself. Therefore, in order to upgrade the maintenance technology of HTTR, the containment leakage rate test program for HTTR was revised by adopting efficient and economical alternatives including Type B and Type C tests' which intend to measure leakage rates for containment penetrations and isolation valves, respectively. In JEAC4203-2004, following requirements are specified for adopting an alternative program: upward trend of the overall integrated leakage rate due to aging affection should not be recognized; performance criterion for combined leakage rate, that is a summation of local leakage rates evaluated by Type B and Type C tests and converted to whole leakage rates, should be established; the criterion of the combined leakage rate should be satisfied as well as of the overall integrated leakage rate; correlation between the overall integrated and combined leakage rates should be recognized. Considering the historical performances, policies of conforming to the forgoing requirements and of carrying out the revised test program were developed, which were accepted by the regulatory agency. This report presents an outline of the leakage rate tests for the reactor containment of HTTR, identifies practical issues of conventional Type A tests, and describes the conforming and implementing policies mentioned above. (author)

  4. Concentrator optical characterization using computer mathematical modelling and point source testing

    Science.gov (United States)

    Dennison, E. W.; John, S. L.; Trentelman, G. F.

    1984-01-01

    The optical characteristics of a paraboloidal solar concentrator are analyzed using the intercept factor curve (a format for image data) to describe the results of a mathematical model and to represent reduced data from experimental testing. This procedure makes it possible not only to test an assembled concentrator, but also to evaluate single optical panels or to conduct non-solar tests of an assembled concentrator. The use of three-dimensional ray tracing computer programs to calculate the mathematical model is described. These ray tracing programs can include any type of optical configuration from simple paraboloids to array of spherical facets and can be adapted to microcomputers or larger computers, which can graphically display real-time comparison of calculated and measured data.

  5. Balloon test project: Cosmic Ray Antimatter Calorimeter (CRAC)

    Science.gov (United States)

    Christy, J. C.; Dhenain, G.; Goret, P.; Jorand, J.; Masse, P.; Mestreau, P.; Petrou, N.; Robin, A.

    1984-01-01

    Cosmic ray observations from balloon flights are discussed. The cosmic ray antimatter calorimeter (CRAC) experiment attempts to measure the flux of antimatter in the 200-600 Mev/m energy range and the isotopes of light elements between 600 and 1,000 Mev/m.

  6. Safety Test Program Summary SNAP 19 Pioneer Heat Source Safety Program

    Energy Technology Data Exchange (ETDEWEB)

    None,

    1971-07-01

    Sixteen heat source assemblies have been tested in support of the SNAP 19 Pioneer Safety Test Program. Seven were subjected to simulated reentry heating in various plasma arc facilities followed by impact on earth or granite. Six assemblies were tested under abort accident conditions of overpressure, shrapnel impact, and solid and liquid propellant fires. Three capsules were hot impacted under Transit capsule impact conditions to verify comparability of test results between the two similar capsule designs, thus utilizing both Pioneer and Transit Safety Test results to support the Safety Analysis Report for Pioneer. The tests have shown the fuel is contained under all nominal accident environments with the exception of minor capsule cracks under severe impact and solid fire environments. No catastrophic capsule failures occurred in this test which would release large quantities of fuel. In no test was fuel visible to the eye following impact or fire. Breached capsules were defined as those which exhibit thoria contamination on its surface following a test, or one which exhibited visible cracks in the post test metallographic analyses.

  7. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    International Nuclear Information System (INIS)

    Cha, Bo Kyung; Jeon, Seongchae; Seo, Chang-Woo

    2016-01-01

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd_2O_2S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  8. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Bo Kyung, E-mail: goldrain99@kaist.ac.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiological Science, Yonsei University, Gangwon-do 220-710 (Korea, Republic of)

    2016-09-21

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  9. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  10. Micro controller application as x-ray machine's high voltage controller

    International Nuclear Information System (INIS)

    Wiranto Budi Santoso; Beny Syawaludin

    2010-01-01

    The micro controller application as x-ray machine's high voltage controller has been carried out. The purpose of this micro controller application is to give an accurate high voltage supply to the x-ray tube so that the x ray machine could produce the result as expected. The micro controller based X-ray machine's high voltage controller receives an input voltage from the keypad. This input value is displayed in the LCD (Liquid Crystal Display) screen. Then micro controller uses this input data to drive the stepper motor. The stepper motor adjusts the high voltage auto transformer's output according to the input value. The micro controller is programmed using BASCOM-B051 compiler. The test results show that the stepper motor could rotate according to an input value. (author)

  11. Analysis of well ER-18-2 testing, Western Pahute Mesa - Oasis Valley FY 2000 testing program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-18-2 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-18-2 Data Report for Development and Hydraulic Testing.

  12. Analysis of Well ER-EC-7 Testing, Western Pahute Mesa - Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-7 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program was documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-7 Data Report for Development and Hydraulic Testing.

  13. Analysis of Well ER-EC-8 testing, Western Pahute Mesa-Oasis Valley FY 2000 testing program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-8 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa-Oasis Valley, Well ER-EC-8 Data Report for development and Hydraulic Testing.

  14. Analysis of Well ER-EC-4 Testing, Western Pahute Mesa-Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-4 during the Western Pahute Mesa-Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-4 Data Report for Development and Hydraulic Testing.

  15. Analysis of Well ER-EC-5 Testing, Western Pahute Mesa-Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-5 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-5 Data Report for Development and Hydraulic Testing.

  16. Analysis of Well ER-EC-6 Testing, Western Pahute Mesa - Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-6 during the Western Pahute Mesa-Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa-Oasis Valley, Well ER-EC-6 Data Report for Development and Hydraulic Testing.

  17. Analysis of Well ER-EC-1 Testing, Western Pahute Mesa-Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-1 during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-1 Data Report for Development and Hydraulic Testing.

  18. Development, implementation and management of a drug testing program in the workplace

    Energy Technology Data Exchange (ETDEWEB)

    Burtis, C.A.

    1990-01-01

    To combat the rising use of drugs in the workplace many American companies have implemented drug testing programs and are testing employees and job applicants for use of illegal drugs. In addition, on September 15, 1986, Executive Order No.12564 was issued by President Reagan, which requires all federal agencies to develop programs and policies, one of the goals of which is to achieve a drug-free federal workplace. Included in this Executive Order is the requirement that federal agencies implement drug testing has become a prevalent practice as a means to detect and deter drug use in the workplace. Before a drug testing program is implemented, it is imperative that policies and procedures are developed that (1) ensure the accuracy of test results, (2) protect the validity and integrity of the specimen, (3) guarantee due process, and (4) maintain confidentiality. To make certain that these prerequisites were met in the government drug testing programs, the US Department of Health and Human Services (HHS) was directed to develop technical and scientific guidelines for conducting such programs. 15 refs., 1 fig., 2 tabs.

  19. Containment Leakage Rate Testing Program in NPP Krsko

    International Nuclear Information System (INIS)

    Dudas, M.; Heruc, Z.

    2002-01-01

    NPP Krsko adopted new regulations for testing of the reactor building containment as stipulated by 10CFR50 (Code of Federal Regulation) Appendix J, Option B instead of the previous requirement 10CFR50 Appendix J now renamed to 10CFR50 Appendix J, Option A. In the USA a thorough analyses of nuclear power plants reactor building containment testing was conducted. As part of these analyses the test results obtained from testing of various reactor-building containments in the last ten years were reviewed. It was concluded that it would be meaningful to, based on test results historical data, reconsider possibility of redefining testing intervals. The official proposal of such approach was reviewed and approved by the NRC and published in September of 1995 in the FR Vol.60 No.186. Based on directions from 10CFR50 Appendix J, Option B, the new criteria for definition of test intervals were created. Criteria were based upon past performance during testing (Performance-based Requirements) and safety impact. At NPP Krsko, the analyses of the Reactor Building Containment. Integrity Test results was performed . This included test results of the Containment Integrated Leak Rate Testing (CILRT or Type A tests), Containment Isolation Valves Local Leak Rater Tests (Type C tests) and Mechanical and Electrical Penetrations Local Leak Rate tests (Type B tests). In accordance with instructions from NEI 94-01 and based on analyses of test results, NPP Krsko created Containment Leakage Rate Testing Program with the purpose to establish the performance-based definition of test intervals, inspection scope, trending and reporting. Equally, the program gives instructions how to evaluate test results and how to deal with the containment penetration or isolation valve repair contingency. All changes caused with transition from Option A to Option B are marginal to public safety. (author)

  20. Large-Scale Seismic Test Program at Hualien, Taiwan

    International Nuclear Information System (INIS)

    Tang, H.T.; Graves, H.L.; Chen, P.C.

    1992-01-01

    The Large-Scale Seismic Test (LSST) Program at Hualien, Taiwan, is a follow-on to the soil-structure interaction (SSI) experiments at Lotung, Taiwan. The planned SSI studies will be performed at a stiff soil site in Hualien, Taiwan, that historically has had slightly more destructive earthquakes in the past than Lotung. The LSST is a joint effort among many interested parties. Electric Power Research Institute (EPRI) and Taipower are the organizers of the program and have the lead in planning and managing the program. Other organizations participating in the LSST program are US Nuclear Regulatory Commission, the Central Research Institute of Electric Power Industry, the Tokyo Electric Power Company, the Commissariat A L'Energie Atomique, Electricite de France and Framatome. The LSST was initiated in January 1990, and is envisioned to be five years in duration. Based on the assumption of stiff soil and confirmed by soil boring and geophysical results the test model was designed to provide data needed for SSI studies covering: free-field input, nonlinear soil response, non-rigid body SSI, torsional response, kinematic interaction, spatial incoherency and other effects. Taipower had the lead in design of the test model and received significant input from other LSST members. Questions raised by LSST members were on embedment effects, model stiffness, base shear, and openings for equipment. This paper describes progress in site preparation, design and construction of the model and development of an instrumentation plan

  1. Hardware test program for evaluation of baseline range/range rate sensor concept

    Science.gov (United States)

    Pernic, E.

    1985-01-01

    The test program Phase II effort provides additional design information in terms of range and range rate (R/R) sensor performance when observing and tracking a typical spacecraft target. The target used in the test program was a one-third scale model of the Hubble Space Telescope (HST) available at the MSFC test site where the tests were performed. A modified Bendix millimeter wave radar served as the R/R sensor test bed for evaluation of range and range rate tracking performance, and generation of radar signature characteristics of the spacecraft target. A summary of program test results and conclusions are presented along with detailed description of the Bendix test bed radar with accompaning instrumentation. The MSFC test site and facilities are described. The test procedures used to establish background levels, and the calibration procedures used in the range accuracy tests and RCS (radar cross section) signature measurements, are presented and a condensed version of the daily log kept during the 5 September through 17 September test period is also presented. The test program results are given starting with the RCS signature measurements, then continuing with range measurement accuracy test results and finally the range and range rate tracking accuracy test results.

  2. Stability Test For Sorghum Mutant Lines Derived From Induced Mutations with Gamma-Ray Irradiation

    Directory of Open Access Journals (Sweden)

    S. Human

    2011-12-01

    Full Text Available Sorghum breeding program had been conducted at the Center for the Application of Isotopes and Radiation Technology, BATAN. Plant genetic variability was increased through induced mutations using gamma-ray irradiation. Through selection process in successive generations, some promising mutant lines had been identified to have good agronomic characteristics with high grain yield. These breeding lines were tested in multi location trials and information of the genotypic stability was obtained to meet the requirements for officially varietal release by the Ministry of Agriculture. A total of 11 sorghum lines and varieties consisting of 8 mutant lines derived from induced mutations (B-100, B-95, B-92, B-83, B-76, B-75, B-69 and Zh-30 and 3 control varieties (Durra, UPCA-S1 and Mandau were included in the experiment. All materials were grown in 10 agro-ecologically different locations namely Gunungkidul, Bantul, Citayam, Garut, Lampung, Bogor, Anyer, Karawaci, Cianjur and Subang. In each location, the local adaptability test was conducted by randomized block design with 3 replications. Data of grain yield was used for evaluating genotypic stability using AMMI approach. Results revealed that sorghum mutation breeding had generated 3 mutant lines (B-100, B-76 and Zh-30 exhibiting grain yield significantly higher than the control varieties. These mutant lines were genetically stable in all locations so that they would be recommended for official release as new sorghum varieties to the Ministry of Agriculture

  3. Hybrid GPU-CPU adaptive precision ray-triangle intersection tests for robust high-performance GPU dosimetry computations

    International Nuclear Information System (INIS)

    Perrotte, Lancelot; Bodin, Bruno; Chodorge, Laurent

    2011-01-01

    Before an intervention on a nuclear site, it is essential to study different scenarios to identify the less dangerous one for the operator. Therefore, it is mandatory to dispose of an efficient dosimetry simulation code with accurate results. One classical method in radiation protection is the straight-line attenuation method with build-up factors. In the case of 3D industrial scenes composed of meshes, the computation cost resides in the fast computation of all of the intersections between the rays and the triangles of the scene. Efficient GPU algorithms have already been proposed, that enable dosimetry calculation for a huge scene (800000 rays, 800000 triangles) in a fraction of second. But these algorithms are not robust: because of the rounding caused by floating-point arithmetic, the numerical results of the ray-triangle intersection tests can differ from the expected mathematical results. In worst case scenario, this can lead to a computed dose rate dramatically inferior to the real dose rate to which the operator is exposed. In this paper, we present a hybrid GPU-CPU algorithm to manage adaptive precision floating-point arithmetic. This algorithm allows robust ray-triangle intersection tests, with very small loss of performance (less than 5 % overhead), and without any need for scene-dependent tuning. (author)

  4. Mechanical properties test program on structural materials in a sodium environment

    International Nuclear Information System (INIS)

    Natesan, K.; Chopra, O.K.; Kassner, T.F.

    1979-10-01

    This document describes in detail the ongoing and planned US Test program on the mechanical properties of sodium-exposed Type 316 austenitic stainless and Fe-2 1/4 Cr-1 Mo ferritic steels. The test program is based on the Development Requirement Specifications (DRS) established by the DOE/Clinch River Breeder Reactor Project (CRBRP) Program Office, the general need for the development of LMFBR structural-design criteria established by the Nuclear Systems Materials Handbook, and the need for a fundamental understanding of materials behavior in a sodium environment, which is generic to LMFBR systems. The planned test program is an extension of work based on current knowledge of sodium chemistry and the influence of sodium purity on the mechanical properties of structural materials

  5. Testing program for concrete at temperatures to 8940K

    International Nuclear Information System (INIS)

    Naus, D.J.; Oland, C.B.; Robinson, G.C.

    1981-01-01

    A test program was conducted to define the variations in mechanical properties of a limestone aggregate concrete and a lightweight insulating concrete exposed to elevated temperatures. Four test series were conducted: (1) unconfined compression; (2) shear; (3) rebar bond; and (4) sustained loading (creep). Tests results are presented

  6. 76 FR 23914 - National Organic Program; Periodic Residue Testing

    Science.gov (United States)

    2011-04-29

    ... NOP. Residue testing plays an important role in organic certification by providing a means for... OFPA (7 U.S.C. 6503 through 6507) from creating certification programs to certify organic farms or... State organic certification program may contain additional requirements for the production and handling...

  7. [Vision test program for ophthalmologists on Apple II, IIe and IIc computers].

    Science.gov (United States)

    Huber, C

    1985-03-01

    A microcomputer program for the Apple II family of computers on a monochrome and a color screen is described. The program draws most of the tests used by ophthalmologists, and is offered as an alternative to a projector system. One advantage of the electronic generation of drawings is that true random orientation of Pflueger's E is possible. Tests are included for visual acuity (Pflueger's E, Landolt rings, numbers and children's drawings). Colored tests include a duochrome test, simple color vision tests, a fixation help with a musical background, a cobalt blue test and a Worth figure. In the astigmatic dial a mobile pointer helps to determine the axis. New tests can be programmed by the user and exchanged on disks among collageues.

  8. Monte Carlo simulation of X-ray imaging and spectroscopy experiments using quadric geometry and variance reduction techniques

    Science.gov (United States)

    Golosio, Bruno; Schoonjans, Tom; Brunetti, Antonio; Oliva, Piernicola; Masala, Giovanni Luca

    2014-03-01

    Licensing provisions: GNU General Public License version 3 No. of lines in distributed program, including test data, etc.: 83617 No. of bytes in distributed program, including test data, etc.: 1038160 Distribution format: tar.gz Programming language: C++. Computer: Tested on several PCs and on Mac. Operating system: Linux, Mac OS X, Windows (native and cygwin). RAM: It is dependent on the input data but usually between 1 and 10 MB. Classification: 2.5, 21.1. External routines: XrayLib (https://github.com/tschoonj/xraylib/wiki) Nature of problem: Simulation of a wide range of X-ray imaging and spectroscopy experiments using different types of sources and detectors. Solution method: XRMC is a versatile program that is useful for the simulation of a wide range of X-ray imaging and spectroscopy experiments. It enables the simulation of monochromatic and polychromatic X-ray sources, with unpolarised or partially/completely polarised radiation. Single-element detectors as well as two-dimensional pixel detectors can be used in the simulations, with several acquisition options. In the current version of the program, the sample is modelled by combining convex three-dimensional objects demarcated by quadric surfaces, such as planes, ellipsoids and cylinders. The Monte Carlo approach makes XRMC able to accurately simulate X-ray photon transport and interactions with matter up to any order of interaction. The differential cross-sections and all other quantities related to the interaction processes (photoelectric absorption, fluorescence emission, elastic and inelastic scattering) are computed using the xraylib software library, which is currently the most complete and up-to-date software library for X-ray parameters. The use of variance reduction techniques makes XRMC able to reduce the simulation time by several orders of magnitude compared to other general-purpose Monte Carlo simulation programs. Running time: It is dependent on the complexity of the simulation. For the examples

  9. Testing the structure of a hydrological model using Genetic Programming

    Science.gov (United States)

    Selle, Benny; Muttil, Nitin

    2011-01-01

    SummaryGenetic Programming is able to systematically explore many alternative model structures of different complexity from available input and response data. We hypothesised that Genetic Programming can be used to test the structure of hydrological models and to identify dominant processes in hydrological systems. To test this, Genetic Programming was used to analyse a data set from a lysimeter experiment in southeastern Australia. The lysimeter experiment was conducted to quantify the deep percolation response under surface irrigated pasture to different soil types, watertable depths and water ponding times during surface irrigation. Using Genetic Programming, a simple model of deep percolation was recurrently evolved in multiple Genetic Programming runs. This simple and interpretable model supported the dominant process contributing to deep percolation represented in a conceptual model that was published earlier. Thus, this study shows that Genetic Programming can be used to evaluate the structure of hydrological models and to gain insight about the dominant processes in hydrological systems.

  10. Medical Imaging Teacher: A program to simulate X-ray images of the body by considering kVp, mAs and FFD values

    Directory of Open Access Journals (Sweden)

    Umit Kara

    2017-06-01

    Full Text Available Introduction: Teaching styles and methods have been constantly changing in the recent years. In the 1980s and 90s, the world was introduced to various developed devices, such as smart boards and early generation smart phones that had an immediate innovative effect on education. These advancements has resulted in a considerable improvement in the current educational techniques. The innovations in medical techniques and their quality is of paramount importance. The aim of this study was to provide an innovative and useful software on radiological applications and contribute to the related literature. Materials and Methods: The Medical Imaging Teacher (MIT program was created and the prototype application was implemented on the Android platform for free use. The programing and testing of the usability of the application were performed by the users of the Google Play Store. Results: In this program, we have developed new software to simulate the X-ray images of the body by considering the peak kilovoltage (kVp, milliamperage per second (mAs, and film focus distance (FFD values. The application has been downloaded more than 1,000 times without paid advertising. We enrolled 131 participants, who made comments and gave 4.8 points on average. Conclusion: It can be concluded that with innovative digital programs, such as the MIT, the medical machine-based learning and medical applications have risen to new levels. The software on medical testing and examination is gaining increasing popularity among the health-related applications for smart phones.

  11. Summary of ROSA-4 LSTF first phase test program and station blackout (TMLB) test results

    International Nuclear Information System (INIS)

    Tasaka, K.; Kukita, Y.; Anoda, Y.

    1990-01-01

    This paper summarizes major test results obtained at the ROSA-4 Large Scale Test Facility (LSTF) during the first phase of the test program. The results from a station blackout (TMLB) test conducted at the end of the first-phase program are described in some detail. The LSTF is an integral test facility being operated by the Japan Atomic Energy Research Institute for simulation of pressurized water reactor (PWR) thermal-hydraulic responses during small-break loss-of-coolant accidents (SBLOCAs) and operational/abnormal transients. It is a 1/48 volumetrically scaled, full-height, full-pressure simulator of a Westinghouse-type 4-loop PWR. The facility includes two symmetric primary loops each one containing an active inverted-U tube steam generator and an active reactor coolant pump. The loop horizontal legs are sized to conserve the scaled (1/24) volumes as well as the length to the square root of the diameter ratio in order to simulate the two-phase flow regime transitions. The primary objective of the LSTF first-phase program was to define the fundamental PWR thermal-hydraulic responses during SBLOCAs and transients. Most of the tests were conducted with simulated component/operator failures, including unavailability of the high pressure injection system and auxiliary feedwater system, as well as operator failure to take corrective actions. The forty-two first phase tests included twenty-nine SBLOCA tests conducted mainly for cold leg breaks, three abnormal transient tests and ten natural circulation tests. Attempts were made in several of the SBLOCA tests to simulate the plant recovery procedures as well as candidate accident management measures for prevention of high-pressure core melt situation. The natural circulation tests simulated the single-phase and two-phase natural circulation as well as reflux condensation behavior in the primary loops in steady or quasi-steady states

  12. Spent fuel sabotage aerosol ratio program : FY 2004 test and data summary.

    Energy Technology Data Exchange (ETDEWEB)

    Brucher, Wenzel (Gesellschaft fur Anlagen- und Reaktorsicherheit, Germany); Koch, Wolfgang (Fraunhofer Institut fur Toxikologie und Experimentelle Medizin, Germany); Pretzsch, Gunter Guido (Gesellschaft fur Anlagen- und Reaktorsicherheit, Germany); Loiseau, Olivier (Institut de Radioprotection et de Surete Nucleaire, France); Mo, Tin (U.S. Nuclear Regulatory Commission, Washington, DC); Billone, Michael C. (Argonne National Laboratory, Argonne, IL); Autrusson, Bruno A. (Institut de Radioprotection et de Surete Nucleaire, France); Young, F. I. (U.S. Nuclear Regulatory Commission, Washington, DC); Coats, Richard Lee; Burtseva, Tatiana (Argonne National Laboratory, Argonne, IL); Luna, Robert Earl; Dickey, Roy R.; Sorenson, Ken Bryce; Nolte, Oliver (Fraunhofer Institut fur Toxikologie und Experimentelle Medizin, Germany); Thompson, Nancy Slater (U.S. Department of Energy, Washington, DC); Hibbs, Russell S. (U.S. Department of Energy, Washington, DC); Gregson, Michael Warren; Lange, Florentin (Gesellschaft fur Anlagen- und Reaktorsicherheit, Germany); Molecke, Martin Alan; Tsai, Han-Chung (Argonne National Laboratory, Argonne, IL)

    2005-07-01

    This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program has been underway for several years. This program provides data that are relevant to some sabotage scenarios in relation to spent fuel transport and storage casks, and associated risk assessments. The program also provides significant technical and political benefits in international cooperation. We are quantifying the Spent Fuel Ratio (SFR), the ratio of the aerosol particles released from HEDD-impacted actual spent fuel to the aerosol particles produced from surrogate materials, measured under closely matched test conditions, in a contained test chamber. In addition, we are measuring the amounts, nuclide content, size distribution of the released aerosol materials, and enhanced sorption of volatile fission product nuclides onto specific aerosol particle size fractions. These data are the input for follow-on modeling studies to quantify respirable hazards, associated radiological risk assessments, vulnerability assessments, and potential cask physical protection design modifications. This document includes an updated description of the test program and test components for all work and plans made, or revised, during FY 2004. It also serves as a program status report as of the end of FY 2004. All available test results, observations, and aerosol analyses plus interpretations--primarily for surrogate material Phase 2 tests, series 2/5A through 2/9B, using cerium oxide sintered ceramic pellets are included. Advanced plans and progress are described for upcoming tests with unirradiated, depleted uranium oxide and actual spent fuel test rodlets. This spent fuel sabotage--aerosol test program is coordinated with the international Working Group for Sabotage Concerns of

  13. Spent fuel sabotage aerosol ratio program : FY 2004 test and data summary

    International Nuclear Information System (INIS)

    Brucher, Wenzel; Koch, Wolfgang; Pretzsch, Gunter Guido; Loiseau, Olivier; Mo, Tin; Billone, Michael C.; Autrusson, Bruno A.; Young, F. I.; Coats, Richard Lee; Burtseva, Tatiana; Luna, Robert Earl; Dickey, Roy R.; Sorenson, Ken Bryce; Nolte, Oliver; Thompson, Nancy Slater; Hibbs, Russell S.; Gregson, Michael Warren; Lange, Florentin; Molecke, Martin Alan; Tsai, Han-Chung

    2005-01-01

    This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program has been underway for several years. This program provides data that are relevant to some sabotage scenarios in relation to spent fuel transport and storage casks, and associated risk assessments. The program also provides significant technical and political benefits in international cooperation. We are quantifying the Spent Fuel Ratio (SFR), the ratio of the aerosol particles released from HEDD-impacted actual spent fuel to the aerosol particles produced from surrogate materials, measured under closely matched test conditions, in a contained test chamber. In addition, we are measuring the amounts, nuclide content, size distribution of the released aerosol materials, and enhanced sorption of volatile fission product nuclides onto specific aerosol particle size fractions. These data are the input for follow-on modeling studies to quantify respirable hazards, associated radiological risk assessments, vulnerability assessments, and potential cask physical protection design modifications. This document includes an updated description of the test program and test components for all work and plans made, or revised, during FY 2004. It also serves as a program status report as of the end of FY 2004. All available test results, observations, and aerosol analyses plus interpretations--primarily for surrogate material Phase 2 tests, series 2/5A through 2/9B, using cerium oxide sintered ceramic pellets are included. Advanced plans and progress are described for upcoming tests with unirradiated, depleted uranium oxide and actual spent fuel test rodlets. This spent fuel sabotage--aerosol test program is coordinated with the international Working Group for Sabotage Concerns of

  14. Describing of elements IO field in a testing computer program

    Directory of Open Access Journals (Sweden)

    Igor V. Loshkov

    2017-01-01

    Full Text Available A standard of describing the process of displaying interactive windows on a computer monitor, through which an output of questions and input of answers are implemented during computer testing, is presented in the article [11]. According to the proposed standard, the description of the process mentioned above is performed with a format line, containing element names, their parameters as well as grouping and auxiliary symbols. Program objects are described using elements of standard. The majority of objects create input and output windows on a computer monitor. The aim of our research was to develop a minimum possible set of elements of standard to perform mathematical and computer science testing.The choice of elements of the standard was conducted in parallel with the development and testing of the program that uses them. This approach made it possible to choose a sufficiently complete set of elements for testing in fields of study mentioned above. For the proposed elements, names were selected in such a way: firstly, they indicate their function and secondly, they coincide with the names of elements in other programming languages that are similar by function. Parameters, their names, their assignments and accepted values are proposed for the elements. The principle of name selection for the parameters was the same as for elements of the standard: the names should correspond to their assignments or coincide with names of similar parameters in other programming languages. The parameters define properties of objects. Particularly, while the elements of standard create windows, the parameters define object properties (location, size, appearance and the sequence in which windows are created. All elements of standard, proposed in this article are composed in a table, the columns of which have names and functions of these elements. Inside the table, the elements of standard are grouped row by row into four sets: input elements, output elements, input

  15. The U.S. Department of Energy Laboratory Accreditation Program for testing the performance of extremity dosimetry systems: a summary of the program status

    International Nuclear Information System (INIS)

    Cummings, F.M.; Carlson, R.D.; Gesell, T.F.; Loesch, R.M.

    1992-01-01

    In 1986, The U.S. Department of Energy (DOE) implemented a program to test the performance of its personnel whole-body dosimetry systems. This program was the DOE Laboratory Accreditation Program (DOELAP). The program parallels the performance testing program specified in the American National Standard for Dosimetry - Personnel Dosimetry Performance -Criteria for Testing (ANSI N13.11-1983), but also addresses the additional dosimetry needs of DOE facilities. As an extension of the whole-body performance testing program, the DOE is now developing a program to test the performance of personnel extremity dosimetry systems. The draft DOE standard for testing extremity dosimetry systems is much less complex than the whole-body dosimetry standard and reflects the limitations imposed on extremity dosimetry by dosimeter design and irradiation geometry. A pilot performance test session has been conducted to evaluate the proposed performance-testing standard. (author)

  16. Computer programs simplify optical system analysis

    Science.gov (United States)

    1965-01-01

    The optical ray-trace computer program performs geometrical ray tracing. The energy-trace program calculates the relative monochromatic flux density on a specific target area. This program uses the ray-trace program as a subroutine to generate a representation of the optical system.

  17. Technical requirements for the actinide source-term waste test program

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, M.L.F.; Molecke, M.A.

    1993-10-01

    This document defines the technical requirements for a test program designed to measure time-dependent concentrations of actinide elements from contact-handled transuranic (CH TRU) waste immersed in brines similar to those found in the underground workings of the Waste Isolation Pilot Plant (WIPP). This test program wig determine the influences of TRU waste constituents on the concentrations of dissolved and suspended actinides relevant to the performance of the WIPP. These influences (which include pH, Eh, complexing agents, sorbent phases, and colloidal particles) can affect solubilities and colloidal mobilization of actinides. The test concept involves fully inundating several TRU waste types with simulated WIPP brines in sealed containers and monitoring the concentrations of actinide species in the leachate as a function of time. The results from this program will be used to test numeric models of actinide concentrations derived from laboratory studies. The model is required for WIPP performance assessment with respect to the Environmental Protection Agency`s 40 CFR Part 191B.

  18. Technical requirements for the actinide source-term waste test program

    International Nuclear Information System (INIS)

    Phillips, M.L.F.; Molecke, M.A.

    1993-10-01

    This document defines the technical requirements for a test program designed to measure time-dependent concentrations of actinide elements from contact-handled transuranic (CH TRU) waste immersed in brines similar to those found in the underground workings of the Waste Isolation Pilot Plant (WIPP). This test program wig determine the influences of TRU waste constituents on the concentrations of dissolved and suspended actinides relevant to the performance of the WIPP. These influences (which include pH, Eh, complexing agents, sorbent phases, and colloidal particles) can affect solubilities and colloidal mobilization of actinides. The test concept involves fully inundating several TRU waste types with simulated WIPP brines in sealed containers and monitoring the concentrations of actinide species in the leachate as a function of time. The results from this program will be used to test numeric models of actinide concentrations derived from laboratory studies. The model is required for WIPP performance assessment with respect to the Environmental Protection Agency's 40 CFR Part 191B

  19. PWR blowdown heat transfer separate-effects program: thermal-hydraulic test facility experimental data report for test 104

    International Nuclear Information System (INIS)

    Leon, D.M.; White, M.D.; Moore, P.A.; Hedrick, R.A.

    1978-01-01

    Reduced instrument responses are presented for Thermal-Hydraulic Test Facility (THTF) test 104, which is part of the ORNL Pressurized-Water Reactor (PWR) Blowdown Heat Transfer Separate-Effects Program. The objective of the program is to investigate the thermal-hydraulic phenomenon governing the energy transfer and transport processes that occur during a loss-of-coolant accident in the PWR system. Test 104 was conducted to obtain CHF in bundle 1 under blowdown conditions. The primary purpose of this report is to make the reduced instrument responses during test 104 available

  20. A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gianoncelli, Alessandra, E-mail: alessandra.gianoncelli@elettra.eu [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bufon, Jernej [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Ahangarianabhari, Mahdi [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Altissimo, Matteo [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bellutti, Pierluigi [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Bertuccio, Giuseppe [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Borghes, Roberto [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Carrato, Sergio [University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Cautero, Giuseppe [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Fabiani, Sergio [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Giacomini, Gabriele [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Giuressi, Dario [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Kourousias, George [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Menk, Ralf Hendrik [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Picciotto, Antonino; Piemonte, Claudio [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Rachevski, Alexandre [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); and others

    2016-04-21

    The last decades have witnessed substantial efforts in the development of several detector technologies for X-ray fluorescence (XRF) applications. In spite of the increasing trend towards performing, cost-effective and reliable XRF systems, detectors for soft X-ray spectroscopy still remain a challenge, requiring further study, engineering and customization in order to yield effective and efficient systems. In this paper we report on the development, first characterization and tests of a novel multielement detector system based on low leakage current silicon drift detectors (SDD) coupled to ultra low noise custom CMOS preamplifiers for synchrotron-based low energy XRF. This new system exhibits the potential for improving the count rate by at least an order of magnitude resulting in ten-fold shorter dwell time at an energy resolution similar to that of single element silicon drift detectors.

  1. The WIPP research and development test program

    International Nuclear Information System (INIS)

    Tyler, L.D.

    1985-01-01

    The WIPP (Waste Isolation Pilot Plant) is a DOE RandD Facility for the purpose of developing the technology needed for the safe disposal of the United States defense-related radioactive waste. The in-situ test program is defined for the thermal-structural interactions, plugging and sealing, and waste package interactions in a salt environment. An integrated series of large-scale underground tests address the issues of both systems and long-term isolation performance of a repository

  2. BWR Full Integral Simulation Test (FIST) program: facility description report

    International Nuclear Information System (INIS)

    Stephens, A.G.

    1984-09-01

    A new boiling water reactor safety test facility (FIST, Full Integral Simulation Test) is described. It will be used to investigate small breaks and operational transients and to tie results from such tests to earlier large-break test results determined in the TLTA. The new facility's full height and prototypical components constitute a major scaling improvement over earlier test facilities. A heated feedwater system, permitting steady-state operation, and a large increase in the number of measurements are other significant improvements. The program background is outlined and program objectives defined. The design basis is presented together with a detailed, complete description of the facility and measurements to be made. An extensive component scaling analysis and prediction of performance are presented

  3. GOSPEG-1 a program for routine analysis of γ-ray spectra by an in line IBM S/7 computer

    International Nuclear Information System (INIS)

    Godio, G.P.; Gozzellino, F.

    1977-01-01

    In this paper a program for routine analysis of γ-ray spectra of samples coming from irradiated nuclear fuel reprocessing plant is described. An IBM S/7 computer (SK words of memory) which is installed at the CNEN-EUREX reprocessing plant and which is in-line connected with a multichannel analyzer and Ge(Li) detector, has been utilized for this work. The program has been written in Assembler S/7 language

  4. Characterization of a Test for Invasive Breast Cancer Using X-ray Diffraction of Hair - Results of a Clinical Trial

    Directory of Open Access Journals (Sweden)

    Gary L. Corino

    2009-11-01

    Full Text Available Objective: To assess the performance of a test for breast cancer utilizing synchrotron x-ray diffraction analysis of scalp hair from women undergoing diagnostic radiology assessment. Design and Setting: A double-blinded clinical trial of women who attended diagnostic radiology clinics in Australia. Patients: 1796 women referred for diagnostic radiology, with no previous history of cancer. Main Outcome Measures: Sensitivity, specificity and accuracy of the hair test analysis compared to the gold standard of imaging followed by biopsy where indicated. Results: The hair-based assay had an overall accuracy of >77% and a negative predictive value of 99%. For all women, the sensitivity of both mammography and x-ray diffraction alone was 64%, but when used together the sensitivity rose to 86%. The sensitivity of the hair test for women under the age of 70 was 74%. Conclusion: In this large population trial the association between the presence of breast cancer and an altered hair fibre X-ray diffraction pattern previously reported has been confirmed. It appears that mammography and X-ray diffraction of hair detect different populations of breast cancers, and are synergistic when used together.

  5. The measurement test of uranium in a uranium-contaminated waste by passive gamma-rays measurement method

    CERN Document Server

    Sukegawa, Y; Ohki, K; Suzuki, S; Yoshida, M

    2002-01-01

    This report is completed about the measurement test and the proofreading of passive gamma - rays measurement method for Non - destructive assay of uranium in a uranium-contaminated waste. The following are the results of the test. 1) The estimation of the amount of uranium by ionization survey meter is difficult for low intensity of gamma-rays emitted from uranium under about 50g. 2) The estimation of the amount of uranium in the waste by NaI detector is possible in case of only uranium, but the estimation from mixed spectrums with transmission source (60-cobalt) is difficult to confirm target peaks. 3) If daughter nuclides of uranium and thorium chain of uranium ore exist, measurement by NaI detector is affected by gamma-rays from the daughter nuclides seriously-As a result, the estimation of the amount of uranium is difficult. 4) The measurement of uranium in a uranium-contaminated waste by germanium detector is possible to estimate of uranium and other nuclides. 5) As to estimation of the amount of uranium...

  6. SSC string test facility for superconducting magnets: Testing capabilities and program for collider magnets

    International Nuclear Information System (INIS)

    Kraushaar, P.; Burgett, W.; Dombeck, T.; McInturff, A.; Robinson, W.; Saladin, V.

    1993-05-01

    The Accelerator Systems String Test (ASST) R ampersand D Testing Facility has been established at the SSC Laboratory to test Collider and High Energy Booster (HEB) superconducting magnet strings. The facility is operational and has had two testing periods utilizing a half cell of collider prototypical magnets with the associated spool pieces and support systems. This paper presents a description of the testing capabilities of the facility with respect to components and supporting subsystems (cryogenic, power, quench protection, controls and instrumentation), the planned testing program for the collider magnets

  7. Detection of ultraviolet Cherenkov light from high energy cosmic ray atmospheric showers: A field test

    International Nuclear Information System (INIS)

    Bartoli, B.; Peruzzo, L.; Sartori, G.; Bedeschi, F.; Bertolucci, E.; Mariotti, M.; Menzione, A.; Ristori, L.; Stefanini, A.; Zetti, F.; Scribano, A.; Budinich, M.; Liello, F.

    1991-01-01

    We present the results of a test with a prototype apparatus aimed to detect the ultraviolet Cherenkov light in the wavelenght range 2000-2300A, emitted by high energy cosmic ray showers. The system consists of a gas proportional chamber, with TMAE vapour as the photosensitive element, placed on the focal plane of a 1.5 m diameter parabolic mirror. The test was done during the summer of 1989 with cosmic ray showers seen in coincidence with the EAS-TOP experiment, an extended atmospheric shower charged particle array now being exploited at Campo Imperatore, 1900 m above sea level, on top of the Gran Sasso underground Laboratory of INFN. The results were positive and show that a full scale ultraviolet Cherenkov experiment with good sensitivity, angular resolution and virtually no background from moonlight or even daylight can be envisaged. (orig.)

  8. Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Itoh, Hideo; Kiuchi, Toshio; Watanabe, Hironori; Kimura, Mamoru; Anoda, Yoshinari

    2001-03-01

    JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to discuss the effect of axial position on thermal-hydraulics, while previous works usually discuss the thermal-hydraulics at the position where the first heat-up occurs. This data report describes test procedure, test condition and major experimental data of post-CHF tests. (author)

  9. EPRI flow-loop/in situ test program for motor-operated valves

    International Nuclear Information System (INIS)

    Hosler, J.F.; Dorfman, L.S.

    1994-01-01

    The Electric Power Research Institute is undertaking a comprehensive research program to develop and validate methods for predicting the performance of common motor-operated gate, global, and butterfly valves. To assess motor-operated valve (MOV) performance characteristics and provide a basis for methods validation, full-scale testing was conducted on 62 MOVs. Tests were performed in four flow-loop facilities and in nine nuclear units. Forty-seven gate, five globe, and 10 butterfly valves were tested under a wide range of flow and differential pressure conditions. The paper describes the test program scope, test configurations, instrumentation and data acquisition, testing approach, and data analysis methods. Key results are summarized

  10. Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-30

    This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are

  11. Los Alamos safeguards program overview and NDA in safeguards

    International Nuclear Information System (INIS)

    Keepin, G.R.

    1988-01-01

    Over the years the Los Alamos safeguards program has developed, tested, and implemented a broad range of passive and active nondestructive analysis (NDA) instruments (based on gamma and x-ray detection and neutron counting) that are now widely employed in safeguarding nuclear materials of all forms. Here very briefly, the major categories of gamma ray and neutron based NDA techniques, give some representative examples of NDA instruments currently in use, and cite a few notable instances of state-of-the-art NDA technique development. Historical aspects and a broad overview of the safeguards program are also presented

  12. X-ray testing for short-time dynamic applications; Roentgenuntersuchungen fuer kurzzeitdynamische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Kurfiss, Malte; Moser, Stefan; Popko, Gregor; Nau, Siegfried [Fraunhofer-Institut fuer Kurzzeitdynamik, Efringen-Kirchen (Germany). Ernst-Mach-Inst. (EMI)

    2017-08-01

    For nondestructive testing purposes new challenges are short-time dynamic processes. The application of x-ray flash tubes and modern high-speed cameras allows the observation of the opening of air-bags or the energy absorption of compressed tubes as occurring during a vehicle crash. Special algorithms designed for computerized tomography analyses allow the 3D reconstruction at individual time points of the dynamic process. Possibilities and limitations of the actual techniques are discussed.

  13. 78 FR 53466 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-08-29

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...

  14. Th/U/Pu/Cm dating of galactic cosmic rays with the extremely heavy cosmic ray composition observer

    Science.gov (United States)

    Westphal, Andrew J.; Weaver, Benjamin A.; Tarlé, Gregory

    The principal goal of ECCO, the Extremely-heavy Cosmic-ray Composition Observer, is the measurement of the age of heavy galactic cosmic-ray nuclei using the extremely rare actinides (Th, U, Pu, Cm) as clocks. ECCO is one of two cosmic-ray instruments comprising the Heavy Nuclei Explorer (HNX), which was recently selected as one of several missions for Phase A study under NASA's Small class Explorer (SMEX) program. ECCO is based on the flight heritage of Trek, an array of barium-phosphate glass tracketch detectors deployed on the Russian space station Mir from 1991-1995. Using Trek, we measured the abundances of elements with Z > 70 in the galactic cosmic rays (GCRs). Trek consisted of a 1 m 2 array of stacks of individually polished thin BP-1 glass detectors. ECCO will be a much larger instrument, but will achieve both excellent resolution and low cost through use of a novel detector configuration. Here we report the results of recent accelerator tests of the ECCO detectors that verify detector performance. We also show the expected charge and energy resolution of ECCO as a function of energy.

  15. 75 FR 58329 - Federal Travel Regulation (FTR); Relocation Expenses Test Programs

    Science.gov (United States)

    2010-09-24

    ... of test programs and possible extensions from 24 months to four years; Redesignates current section... conducting test programs. C. Executive Order 12866 This regulation is excepted from the definition of... adding ``12'' in its place. Sec. 300-80.6 [Amended] 0 3. Amend Sec. 300.80-6 by-- 0 a. Removing the word...

  16. Local gamma ray events as tests of the antimatter theory of gamma ray bursts

    International Nuclear Information System (INIS)

    Sofia, S.; Wilson, R.E.

    1976-01-01

    Nearby examples of the antimatter 'chunks' postulated by Sofia and Van Horn to explain the cosmic gamma ray bursts may produce detectable gamma ray events when struck by solar system meteoroids. These events would have a much shorter time scale and higher energy spectrum than the bursts already observed. In order to have a reasonably high event rate, the local meteoroid population must extend to a distance from the Sun of the order of 0.1 pc, but the required distance could become much lower if the instrumental threshold is improved. The expected gamma ray flux for interaction of the antimatter bodies with the solar wind is also examined, and found to be far below present instrumental capabilities. (Auth.)

  17. Gamma-Ray Peak Integration: Accuracy and Precision

    International Nuclear Information System (INIS)

    Richard M. Lindstrom

    2000-01-01

    The accuracy of singlet gamma-ray peak areas obtained by a peak analysis program is immaterial. If the same algorithm is used for sample measurement as for calibration and if the peak shapes are similar, then biases in the integration method cancel. Reproducibility is the only important issue. Even the uncertainty of the areas computed by the program is trivial because the true standard uncertainty can be experimentally assessed by repeated measurements of the same source. Reproducible peak integration was important in a recent standard reference material certification task. The primary tool used for spectrum analysis was SUM, a National Institute of Standards and Technology interactive program to sum peaks and subtract a linear background, using the same channels to integrate all 20 spectra. For comparison, this work examines other peak integration programs. Unlike some published comparisons of peak performance in which synthetic spectra were used, this experiment used spectra collected for a real (though exacting) analytical project, analyzed by conventional software used in routine ways. Because both components of the 559- to 564-keV doublet are from 76 As, they were integrated together with SUM. The other programs, however, deconvoluted the peaks. A sensitive test of the fitting algorithm is the ratio of reported peak areas. In almost all the cases, this ratio was much more variable than expected from the reported uncertainties reported by the program. Other comparisons to be reported indicate that peak integration is still an imperfect tool in the analysis of gamma-ray spectra

  18. Metamorphic Testing Integer Overflow Faults of Mission Critical Program: A Case Study

    Directory of Open Access Journals (Sweden)

    Zhanwei Hui

    2013-01-01

    Full Text Available For mission critical programs, integer overflow is one of the most dangerous faults. Different testing methods provide several effective ways to detect the defect. However, it is hard to validate the testing outputs, because the oracle of testing is not always available or too expensive to get, unless the program throws an exception obviously. In the present study, the authors conduct a case study, where the authors apply a metamorphic testing (MT method to detect the integer overflow defect and alleviate the oracle problem in testing critical program of Traffic Collision Avoidance System (TCAS. Experimental results show that, in revealing typical integer mutations, compared with traditional safety property testing method, MT with a novel symbolic metamorphic relation is more effective than the traditional method in some cases.

  19. Experimental Program for the CLIC test facility 3 test beam line

    CERN Document Server

    Adli, E; Dobert, S; Olvegaard, M; Schulte, D; Syratchev, I; Lillestol, Reidar

    2010-01-01

    The CLIC Test Facility 3 Test Beam Line is the first prototype for the CLIC drive beam decelerator. Stable transport of the drive beam under deceleration is a mandatory component in the CLIC two-beam scheme. In the Test Beam Line more than 50% of the total energy will be extracted from a 150 MeV, 28 A electron drive beam, by the use of 16 power extraction and transfer structures. A number of experiments are foreseen to investigate the drive beam characteristics under deceleration in the Test Beam Line, including beam stability, beam blow up and the efficiency of the power extraction. General benchmarking of decelerator simulation and theory studies will also be performed. Specially designed instrumentation including precision BPMs, loss monitors and a time-resolved spectrometer dump will be used for the experiments. This paper describes the experimental program foreseen for the Test Beam Line, including the relevance of the results for the CLIC decelerator studies.

  20. CRIEPI test program for seismic isolation of the FBR

    International Nuclear Information System (INIS)

    Shiojiri, Hiroo

    1989-01-01

    This paper describes the Central Research Institute of Electric Power Industry's (CRIEPIs) seismic isolation program. The test and research program on seismic isolation was started in 1987 by CRIEPI under contract with the Ministry of International Trade and Industry (MITI) of Japan. It was intended to establish a technical basis for the application of seismic isolation to fast breeder reactors (FBRs). In this paper, some details of the program and results of the preliminary study are described

  1. Cosmic ray test of the Belle II z-vertex trigger

    Energy Technology Data Exchange (ETDEWEB)

    Neuhaus, Sara; Skambraks, Sebastian [Technische Universitaet Muenchen (Germany); Chen, Yang; Kiesling, Christian [Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2016-07-01

    The z-vertex trigger is part of the first level track trigger in the Belle II experiment. Its task is the rejection of tracks not coming from the interaction region, suppressing a large part of the machine background. Therefore the z-vertex trigger allows to relax other track trigger conditions and thus strongly increases the efficiency for channels with low track multiplicity (e.g. tau pair production). The track trigger works in several steps, first combining hits to track segments, followed by a 2D track finding in the transverse plane and finally the 3D reconstruction. Our method employs neural networks to estimate the z-vertex without explicit track reconstruction. For the first real test with cosmic rays special neural networks have been prepared. Although the track shape in the cosmic test is different than in the Belle II experiment, the neural networks require only a retraining with an appropriate data set to adapt to the new geometry.

  2. Active vibration control testing of the SPICES program: final demonstration article

    Science.gov (United States)

    Dunne, James P.; Jacobs, Jack H.

    1996-05-01

    The Synthesis and Processing of Intelligent Cost Effective Structures (SPICES) Program is a partnership program sponsored by the Advanced Research Projects Agency. The mission of the program is to develop cost effective material processing and synthesis technologies to enable new products employing active vibration suppression and control devices to be brought to market. The two year program came to fruition in 1995 through the fabrication of the final smart components and testing of an active plate combined with two trapezoidal rails, forming an active mount. Testing of the SPICES combined active mount took place at McDonnell Douglas facilities in St. Louis, MO, in October-December 1995. Approximately 15 dB reduction in overall response of a motor mounted on the active structure was achieved. Further details and results of the SPICES combined active mount demonstration testing are outlined. Results of numerous damping and control strategies that were developed and employed in the testing are presented, as well as aspects of the design and fabrication of the SPICES active mount components.

  3. The X-ray imager on AXO

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; Kuvvetli, Irfan; Westergaard, Niels Jørgen Stenfeldt

    2001-01-01

    DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated....... Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray...... Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active...

  4. New challenges in ray tracing simulations of X-ray optics

    International Nuclear Information System (INIS)

    Río, M Sánchez del

    2013-01-01

    The construction of new synchrotron sources and the refurbishment and upgrade of existing ones has boosted in the last years the interest in X-ray optics simulations for beamline design and optimization. In the last years we conducted a full renewal of the well established SHADOW ray tracing code, ending with a modular version SHADOW3 interfaced to multiple programming languages (C, C++, IDL, Python). Some of the new features of SHADOW3 are presented. From the physics point of view, SHADOW3 has been upgraded for dealing with lens systems. X-ray partial coherence applications demand an extension of traditional ray tracing methods into a hybrid ray-tracing wave-optics approach. The software development is essential for fulfilling the requests of the ESRF Upgrade Programme, and some examples of calculations are also presented.

  5. Basic design of on-line analyzer for sheet paper using X-ray fluorescence (XRF) technique

    International Nuclear Information System (INIS)

    Rony Djokorayono; Ahmad Suntoro; Ikhsan Shobari; Usep Setia Gunawan

    2016-01-01

    Basic design of on-line analyzer for sheet paper using X-ray fluorescence technique has been carried out. Compared with sampling technique, this X-ray fluorescence technique has some advantages in term of analysis accuracy and time. The design activities performed including the establishment of design requirements, functional requirements, technical requirements, technical specification, detection sub-system design, data acquisition sub-system design, and operator computer console design. This program will use silicon drift or CdTe X-ray detector to detect X-ray fluorescence emitted by elements in sheet paper due to X-ray interaction of a X-ray source, 55 Fe (Ferro-55).This basic design of on-line analyzer for sheet paper using X-ray fluorescence technique should be followed up with the development of detailed design, prototype construction, and field testing. (author)

  6. Philips high tension generator (x-ray machine) testing for baby ebm (electron beam machine) project

    International Nuclear Information System (INIS)

    Norman Awalludin; Leo Kwee Wah; Abu Bakar Mhd Ghazali

    2005-01-01

    This paper describes the test of the HT system (from X-ray machine) for usage of the mini EBM (Electron Beam Machine). It consists the procedures of the installation, the safety procedures when deals with HT, modification of the system for testing purpose and the technique/method for testing the HT system. As a result, the voltage for the HT system and the electron gun (filament) current can be measured. Based on the results, suitability of the machine for baby EBM could be confirmed. (Author)

  7. US/French joint research program regarding the behavior of polymer base materials subjected to beta radiation: Volume 2, Phase-2a screening tests: [Final report

    International Nuclear Information System (INIS)

    Buckalew, W.H.; Wyant, F.J.; Chenion, J.; Carlin, F.; Gaussens, G.; Le Tutour, P.; Le Meur, M.

    1987-09-01

    As part of the ongoing joint NRC/CEA cooperative test program to investigate the relative effectiveness of beta and gamma irradiation to produce damage in polymer base materials, ethylene propylene rubber (EPR) specimens, in slab geometry, were exposed to Cobalt-60 gamma rays and accelerator produced electron beams. Specimens were irradiated and evaluated at research facilities in the US (Sandia National Laboratories) and France (Compagnie ORIS Industrie). These tests included several electron beam energies, sample thicknesses, exposure doses, and dose rates. Based on changes in the tensile properties, of the test specimens, results of these studies suggest that material damage resulting from electron and gamma irradiations can be correlated on the basis of absorbed radiation dose

  8. Testing program PIN on experiments reported in EPRI-NP-369

    International Nuclear Information System (INIS)

    Kunt, J.; Pazdera, F.

    1980-03-01

    The testing is described of the applicability of program PIN for the thermomechanical simulation of PWR fuel elements. Program PIN is a modified program GAPCON-THERMAL-2. Four modifications are presented mostly affecting the results, viz., the fuel restructuring model, the fuel densification model, the gaseous fission product release model, and the fuel cladding creep model. The results show that the initial data for simulating fuel element behaviour in accident situations are determined using program PIN with accuracy comparable to that using other programs. (J.P.)

  9. Modern industrial devices of X-ray radioscopy and fluorography for nondestructive testing of welded joints

    International Nuclear Information System (INIS)

    Leonov, B.I.; Sosnin, F.R.; Luk'yanenko, Eh.A.; Veselovskij, L.N.; Kanter, B.M.; Zhdanov, A.V.

    1984-01-01

    Technical data on industrial X-ray television systems with new convertors are given. The convertors are characterized by high sensitivity, defect detectability, lower noise level as compared to earlier produced equipment. Flu uorographic installation for testing welded joints of thick metals is described

  10. Reliability test: X-ray ring exit chambers crotch radiation absorbers. Final report

    International Nuclear Information System (INIS)

    Lynch, D.R.; Morgan, J.

    1999-01-01

    This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. These absorbers are part of the 16 dipole vacuum chambers which comprise the arc sections of the ring. They are located at the intersections (crotch) of the beamline exit ports with the electron beam chamber, and are commonly referred to as crotches. The purpose of these efforts was to demonstrate the reliability of the crotches under operating conditions that the crotches will be subjected to over the entire expected life of the ring. The efforts described include engineering calculations, finite element analysis, conceptual design for a reliability test, test implementation and descriptions, results and conclusions related to these analyses and tests

  11. Novel X-ray imaging diagnostics of high energy nanosecond pulse accelerators

    International Nuclear Information System (INIS)

    Smith, Graham W.; Gallegos, Roque Rosauro; Hohlfelder, Robert James; Beutler, David Eric; Dudley, John; Seymour, Calvin L.G.; Bell, John D.

    2004-01-01

    Pioneering x-ray imaging has been undertaken on a number of AWE's and Sandia National Laboratories radiation effects x-ray simulators. These simulators typically yield a single very short (<50ns) pulse of high-energy (MeV endpoint energy bremsstrahlung) x-ray radiation with doses in the kilorad (krad(Si)) region. X-ray source targets vary in size from 2 to 25cm diameter, dependent upon the particular simulator. Electronic imaging of the source x-ray emission under dynamic conditions yields valuable information upon how the simulator is performing. The resultant images are of interest to the simulator designer who may configure new x-ray source converter targets and diode designs. The images can provide quantitative information about machine performance during radiation effects testing of components under active conditions. The effects testing program is a valuable interface for validation of high performance computer codes and models for the radiation effects community. A novel high-energy x-ray imaging spectrometer is described whereby the spectral energy (0.1 to 2.5MeV) profile may be discerned from the digitally recorded and viewable images via a pinhole/scintillator/CCD imaging system and knowledge of the filtration parameters. Unique images, analysis and a preliminary evaluation of the capability of the spectrometer are presented. Further, a novel time resolved imaging system is described that captures a sequence of high spatial resolution temporal images, with zero interframe time, in the nanosecond timeframe, of our source x-rays.

  12. Assembly of NASA's Most Powerful X-Ray Telescope Completed

    Science.gov (United States)

    1998-03-01

    Assembly of the world's most powerful X-ray telescope, NASA's Advanced X-ray Astrophysics Facility, was completed last week with the installation of its power-generating twin solar panels. The observatory is scheduled for launch aboard Space Shuttle mission STS-93, in December 1998. The last major components of the observatory were bolted and pinned into place March 4 at TRW Space & Electronics Group in Redondo Beach, Calif., and pre-launch testing of the fully assembled observatory began March 7. "Completion of the observatory's assembly process is a big step forward toward launch scheduled for the end of this year," said Fred Wojtalik, manager of the Observatory Projects Office at NASA's Marshall Space Flight Center in Huntsville, Ala. "With all the major components in place, we are now concentrating on a thorough pre-launch checkout of the observatory." "We're delighted to reach this major milestone for the program," said Craig Staresinich, TRW's Advanced X-ray Astrophysics Facility program manager. "The entire observatory team has worked hard to get to this point and will continue an exhaustive test program to ensure mission success. We're looking forward to delivering a truly magnificent new space capability to NASA later this summer." The first pre-launch test of the Advanced X-ray Astrophysics Facility was an acoustic test, which simulated the sound pressure environment inside the Space Shuttle cargo bay during launch. A thorough electrical checkout before and after the acoustic test verifies that the observatory and its science instruments can withstand the extreme sound levels and vibrations that accompany launch. "With 10 times the resolution and 50-100 times the sensitivity of any previous X-ray telescope, this observatory will provide us with a new perspective of our universe," said the project's chief scientist, Dr. Martin Weisskopf of Marshall Center. "We'll be able to study sources of X-rays throughout the universe, like colliding galaxies and black

  13. ATLAS RPC commissioning status and cosmic ray test results

    CERN Document Server

    Bianco, Michele

    2009-01-01

    The muon trigger system of the ATLAS experiment consists of several sub-systems and each of them need to be tested and certified before LHC operation. In the barrel region Resistive Plate Chambers are employed. RPC detector and its level-1 trigger electronics are designed to detect and select high momentum muons with high time resolution and good tracking capability for a total surface of about 4000 m2. The commissioning phase provided an unique opportunity to demonstrate, before LHC start-up, the functionality of the muon trigger components such as detector chambers, level-1 trigger electronics, detector slow control system, data acquisition chain, software and computing. We present the status of ATLAS RPC detector, the problems met during the commissioning and the solutions found and, finally, its performances as obtained by acquiring cosmic rays.

  14. Marriage of x-ray and optical astronomy

    International Nuclear Information System (INIS)

    McClintock, J.E.

    1975-01-01

    An historical discussion of the relation of x-ray and optical astronomy is given including distances within our galaxy, the optical identification of x-ray sources, the binary x-ray stars, neutron stars and black holes, a program in x-ray astronomy, and future missions

  15. ABCOVE program: preliminary results of tests AB5 and AB6

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Muhlestein, L.D.

    1984-01-01

    A program for aerosol behavior code validation and evaluation (ABCOVE) is in progress in the United States. Purpose of the ABCOVE program is to provide a basis for judging the adequacy of existing aerosol behavior computer codes to describe inherent aerosol behavior in containment buildings during postulated breeder reactor accidents. The program involves pretest calculations by code developers and users, large-scale confirmatory tests in the 850-m 3 containment vessel of the Containment Systems Test Facility (CSTF), and blind post-test analyses and comparisons with experimental data. Two ABCOVE tests have been performed in the CSTF to date. In the first test, a single-species aerosol was used, with the aerosol being generated by spraying sodium at a high rate into an air atmosphere. In the second test, the experimental conditions simulated an accident environment in which a fission product aerosol, NaI, was released in the presence of a sodium fire. Pretest computer code predictions were made by seven organizations using eight computer codes (HAA-3, HAA-4, HAARM-3, SOFIA, QUICK, QUICKM, MAEROS, and CONTAIN)

  16. Testing Automation of Context-Oriented Programs Using Separation Logic

    Directory of Open Access Journals (Sweden)

    Mohamed A. El-Zawawy

    2014-01-01

    Full Text Available A new approach for programming that enables switching among contexts of commands during program execution is context-oriented programming (COP. This technique is more structured and modular than object-oriented and aspect-oriented programming and hence more flexible. For context-oriented programming, as implemented in COP languages such as ContextJ* and ContextL, this paper introduces accurate operational semantics. The language model of this paper uses Java concepts and is equipped with layer techniques for activation/deactivation of layer contexts. This paper also presents a logical system for COP programs. This logic is necessary for the automation of testing, developing, and validating of partial correctness specifications for COP programs and is an extension of separation logic. A mathematical soundness proof for the logical system against the proposed operational semantics is presented in the paper.

  17. X-Ray Microtomography (μCT as a Useful Tool for Visualization and Interpretation of Shear Strength Test Results

    Directory of Open Access Journals (Sweden)

    Stefaniuk Damian

    2015-02-01

    Full Text Available The paper demonstrates the applicability of X-ray microtomography (ìCT to analysis of the results of shear strength examinations of clayey soils. The method of X-ray three-dimensional imaging offers new possibilities in soil testing. The work focuses on a non-destructive method of evaluation of specimen quality used in shear tests and mechanical behavior of soil. The paper presents the results of examination of 4 selected clayey soils. Specimens prepared for the triaxial test have been scanned using ìCT before and after the triaxial compression tests. The shear strength parameters of the soils have been estimated. Changes in soil structure caused by compression and shear failure have been presented as visualizations of the samples tested. This allowed for improved interpretation and evaluation of soil strength parameters and recognition of pre-existing fissures and the exact mode of failure. Basic geometrical parameters have been determined for selected cross-sections of specimens after failure. The test results indicate the utility of the method applied in soil testing.

  18. Validation of the X-ray fluorescence analysis method for coffee grain testing

    International Nuclear Information System (INIS)

    Samaniego, Carlos

    1992-01-01

    Trace elements were qualitatively and quantitatively searched for in coffee samples for analysis were prepared in tablet from before irradiation, this latter having been performed with a Cd 109 radioactive source and with an X-ray tube; with ZnO as the secondary target. Several spectra were obtained. The areas of the spectral peaks were adjusted with the aid of AXIL computer program wich is based on the least squares method. Further on, elemental concentrations were determined by means of sensitivity and regression curves (intensity vs. concentration), methods that demanded the use of pertinent standards, concentration in organic standard certified samples furthermore, atomic absorption was also used to perform comparative checks on results

  19. Development of the water window imaging x-ray microscope

    International Nuclear Information System (INIS)

    Hoover, R.B.; Shealy, D.L.; Baker, P.C.; Barbee, T.W. Jr.; Walker, A.B.C. Jr.

    1991-01-01

    This paper reports on the Water Window Imaging X-ray Microscopy which is currently being developed by a consortium from the Marshall Space Flight Center, the University of Alabama at Birmingham, Baker Consulting, the Lawrence Livermore National Laboratory, and Stanford University. The high quality solar images achieved during the Stanford/MSFC/LLNL Rocket X-ray Spectroheliograph flight conclusively established that excellent imaging could be obtained with doubly reflecting multilayer optical systems. Theoretical studies carried out as part of the MSFC X-ray Microscopy Program, demonstrated that high quality, high resolution multilayer x-ray imaging microscopes could be achieved with spherical optics in the Schwarzschild configuration and with Aspherical optical systems. Advanced Flow Polishing methods have been used to fabricate substrates for multilayer optics. On hemlite grade Sapphire, the authors have achieved microscopy mirror substrates on concave and convex spherical surfaces with 0.5 Angstrom rms surface smoothness, as measured by the Zygo profilometer. In this paper the authors report on the current status of fabrication and testing of the optical and mechanical subsystems for the Water Window Imaging X-ray Microscope

  20. Analysis of Well ER-EC-2a Testing, Western Pahute Mesa-Oasis Valley FY 2000 Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-09-30

    This report documents the analysis of the data collected for Well ER-EC-2a during the Western Pahute Mesa - Oasis Valley (WPM-OV) well development and testing program that was conducted during fiscal year (FY) 2000. The data collection for that program is documented in Appendix A, Western Pahute Mesa - Oasis Valley, Well ER-EC-2a Data Report for Development and Hydraulic Testing.

  1. Indicators for monitoring screening programs with primary HPV test.

    Science.gov (United States)

    Zorzi, Manuel; Giorgi Rossi, Paolo

    2017-01-01

    following scientific evidence produced in numerous studies, as well as national and international guidelines, organized cervical cancer screening programs in Italy have gradually introduced the HPV test as primary screening test, replacing cytology. As public health interventions, screening programs must ensure equity, improvement in quality of life, and adequate information for the population involved with regards to benefits and possible risks; therefore, it is essential for quality to be constantly checked at every phase of the project.The Italian Cervical Screening Group (Gruppo Italiano per lo Screening Cervicale, GISCi) has written a handbook for the calculation and interpretation of cervical screening program monitoring indicators that take into account the new protocol based on primary HPV test with cytology triage. based on the European guidelines and Italian recommendations on primary HPVbased screening, the working group, which includes professionals from all the fields involved in cervical screening, identified the essential points needed to monitor the screening process, the accuracy of individual tests, and early outcomes, defining a specific indicator for each aspect. The indicators were grouped as follows: baseline indicators, indicators for test repeat after one year, cumulative indicators, and waiting times. For every indicator, the source of data, calculation formula, any standards or critical thresholds, and interpretation were defined. The standards are based on the results of NTCC trials or Italian pilot studies. the main indicators proposed for the organization are the following: number of invitations, compliance with first invitation, with one-year test repeat and with colposcopy; for test and process accuracy, a cohort approach was utilised, where indicators are based on women who must be followed for at least one year, so as to integrate the results obtained after the first HPV test with the outcome of the test's repetition after one year

  2. Gamma-Ray Imaging Spectrometer (GRIS): a new balloon-borne experiment for gamma-ray line astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.; Cline, T.L.; Gehrels, N.; Porreca, G.; Tueller, J.; Leventhal, M.; Huters, A.F.; Maccallum, C.J.; Stang, P.D.; Sandia Labs., Albuquerque, NM)

    1985-01-01

    High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments

  3. The Advanced Test Reactor Strategic Evaluation Program

    International Nuclear Information System (INIS)

    Buescher, B.J.

    1990-01-01

    A systematic evaluation of safety, environmental, and operational issues has been initiated at the Advanced Test Reactor (ATR). This program, the Strategic Evaluation Program (STEP), provides an integrated review of safety and operational issues against the standards applied to licensed commercial facilities. In the review of safety issues, 18 deviations were identified which required prompt attention. Resolution of these items has been accelerated in the program. An integrated living schedule is being developed to address the remaining findings. A risk evaluation is being performed on the proposed corrective actions and these actions will then be formally ranked in order of priority based on considerations of safety and operational significance. Once the final ranking is completed, an integrated schedule will be developed, which will include considerations of availability of funding and operating schedule. 3 refs., 2 figs

  4. An overview of the United States dose reassessment program

    International Nuclear Information System (INIS)

    Christy, R.F.

    1983-01-01

    The US Dose Reassessment Program consists of a number of separate efforts to reexamine all the stages from the initial assembly of the fissionable material, through the transport of neutrons and gamma rays, to the final deposition of the dose of ionizing radiation. Where possible, experimental measurements will be used to normalize the calculations. This program is summarized as follows: (1) calculations on the output of prompt neutrons and gamma rays from the detonating bomb, by Los Alamos National Laboratory (LANL), including calculation of the output of various test bombs where measurements have been made and of a critical assembly of a Hiroshima type bomb, (2) transport calculations for prompt neutrons and gamma rays in air by Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) including transport in air of gamma rays secondary to prompt neutrons and calculation of various test devices, (3) calculation of the emission and transport in air of delayed gamma rays from the cloud of fission products by Science Applications, Inc. (SAI) which can also include delayed neutron calculations, (4) calculations of the shielding effects of buildings, etc., on the neutron and gamma ray flux by SAI and ORNL, (5) calculation of organ doses and transport in the body by ORNL and SAI, (6) calibration of in situ measurements by LLNL and ORNL, (7) thermoluminescent (TL) dosimetry to determine gamma ray flux by the Japanese National Institute of Radiological Sciences and the University of Utah, and (8) review of information on bomb yield by LANL and ORNL. (author)

  5. Research of x-ray nondestructive detector for high-speed running conveyor belt with steel wire ropes

    Science.gov (United States)

    Wang, Junfeng; Miao, Changyun; Wang, Wei; Lu, Xiaocui

    2008-03-01

    An X-ray nondestructive detector for high-speed running conveyor belt with steel wire ropes is researched in the paper. The principle of X-ray nondestructive testing (NDT) is analyzed, the general scheme of the X-ray nondestructive testing system is proposed, and the nondestructive detector for high-speed running conveyor belt with steel wire ropes is developed. The hardware of system is designed with Xilinx's VIRTEX-4 FPGA that embeds PowerPC and MAC IP core, and its network communication software based on TCP/IP protocol is programmed by loading LwIP to PowerPC. The nondestructive testing of high-speed conveyor belt with steel wire ropes and network transfer function are implemented. It is a strong real-time system with rapid scanning speed, high reliability and remotely nondestructive testing function. The nondestructive detector can be applied to the detection of product line in industry.

  6. BGSUB and BGFIX: FORTRAN programs to correct Ge(Li) gamma-ray spectra for photopeaks from radionuclides in background

    International Nuclear Information System (INIS)

    Cutshall, N.H.; Larsen, I.L.

    1980-03-01

    Two FORTRAN programs which provide correction and error analysis for background photopeak contributions to low-level gamma-ray spectra are discussed. A peak-by-peak background subtraction approach is used instead of channel-by-channel correction. The accuracy of corrected results near background levels is substantially improved over uncorrected values

  7. A setup to perform X-ray irradiation tests on scintillating fibres for the SciFi project

    CERN Document Server

    Gavardi, Laura; Joram, Christian; Kristic, Robert

    2017-01-01

    An X-ray setup has been installed at CERN. The setup will serve for quality assurance purposes related to the acceptance of $11'000~ \\text{km}$ of scintillating plastic fibres for the SciFi detector of LHCb. The X-ray tube has a tungsten target and can be powered up to 60kV, 30mA. The setup is intended to monitor the relative radiation response of the different fibre batches. The dose rate absorbed by the fibre under test can be tuned, adjusting the settings of the X-ray tube and adding aluminium filters of different thicknesses. When operating the X-ray tube without filters at a high voltage of $40\\rm \\,kV$ and an anode current of $30\\rm \\,mA$, the dose rate is about $23\\rm \\,Gy/min$. The maximum dose of about $35\\rm \\,kGy$ expected in the SciFi Tracker can be thus reached in about $1\\rm \\,day$.

  8. Radiation protection type testing and licensing of diagnostic X-ray equipment in the GDR

    International Nuclear Information System (INIS)

    Taschner, P.; Poulheim, K.F.; Feldheim, W.

    1987-01-01

    The results of more than 10 years experience in type testing and type licensing of diagnostic X-ray equipment with respect to meeting radiation protection requirements as well as the implications for the conduct of these procedures resulting from the introduction of new radiation protection legislation in 1983 and 1984, are described. At present an updated version of the 'Regulation of 16 December 1977 concerning radiation protection type testing and licensing of sealed radiation sources and equipment emitting ionizing radiation' is being prepared. (author)

  9. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  10. Preliminary irradiation test results from the Yankee Atomic Electric Company reactor vessel test irradiation program

    International Nuclear Information System (INIS)

    Biemiller, E.C.; Fyfitch, Stephen; Campbell, C.A.

    1994-01-01

    The Yankee Atomic Electric Company test irradiation program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials and to remove uncertainties in the analysis of existing irradiation data on the Yankee Rowe reactor vessel steel. Plate materials each containing 0.24 w/o copper, but different nickel contents at 0.63 w/o and 0.19 w/o, were heat treated to simulate the Yankee vessel heat treatment (austenitized at 982 o C (1800 o F)) and to simulate Regulatory Guide 1.99 database materials (austenitized at 871 o C (1600 o F)). These heat treatments produced different microstructures so the effect of microstructure on irradiation damage sensitivity could be tested. Because the nickel content of the test plates varied and the copper level was constant, the effect of nickel on irradiation embrittlement was also tested. Correlation monitor material, HSST-02, was included in the program to benchmark the Ford Nuclear Reactor (University of Michigan Test Reactor) which had never been used before for this type of irradiation program. Materials taken from plate surface locations (versus 1/4 T) were included to test whether or not the improved toughness properties of the plate surface layer, resulting from the rapid quench, are maintained after irradiation. If the improved properties are maintained, pressurized thermal shock calculations could utilize this margin. Finally, for one experiment, irradiations were conducted at two irradiation temperatures (260 o C and 288 o C) to determine the effect of irradiation temperature on embrittlement. (Author)

  11. Procedures and reasoning for skill proficiency testing in physical education teacher education programs

    Directory of Open Access Journals (Sweden)

    Timothy Baghurst

    2015-12-01

    Full Text Available This study sought to determine how the testing of skill proficiency is being conducted in physical education teacher education (PETE programs in the USA and how fitness or skill proficiencies, as attributes of a physical educator, are perceived. Participants were 312 college PETE program coordinators who completed an online survey about skill testing in their program. The eligible respondents yielded a 52.7% total response rate. Most participants believed that skill proficiency for PETE students was important, but only 46% of programs reported testing within their program. Many participants stated it was possible for their students to graduate without demonstrating proficiency in skill technique, yet were confident their students would pass an independent skill test. Only 46.2% of respondents indicated their students needed to demonstrate proper skill technique in order to graduate, and there was no consistent method of assessment. Responses were evenly split regarding the importance of a physical educator being able to demonstrate proper skill technique or be physically fit. The lack of skill testing in programs, combined with the variation in assessment, is concerning, and the development of a standardized skill-based test may provide more rigor to this important area of teacher credibility and effectiveness.

  12. Modeling UV Radiation Feedback from Massive Stars. I. Implementation of Adaptive Ray-tracing Method and Tests

    Science.gov (United States)

    Kim, Jeong-Gyu; Kim, Woong-Tae; Ostriker, Eve C.; Skinner, M. Aaron

    2017-12-01

    We present an implementation of an adaptive ray-tracing (ART) module in the Athena hydrodynamics code that accurately and efficiently handles the radiative transfer involving multiple point sources on a three-dimensional Cartesian grid. We adopt a recently proposed parallel algorithm that uses nonblocking, asynchronous MPI communications to accelerate transport of rays across the computational domain. We validate our implementation through several standard test problems, including the propagation of radiation in vacuum and the expansions of various types of H II regions. Additionally, scaling tests show that the cost of a full ray trace per source remains comparable to that of the hydrodynamics update on up to ∼ {10}3 processors. To demonstrate application of our ART implementation, we perform a simulation of star cluster formation in a marginally bound, turbulent cloud, finding that its star formation efficiency is 12% when both radiation pressure forces and photoionization by UV radiation are treated. We directly compare the radiation forces computed from the ART scheme with those from the M 1 closure relation. Although the ART and M 1 schemes yield similar results on large scales, the latter is unable to resolve the radiation field accurately near individual point sources.

  13. Monolithic CMOS imaging x-ray spectrometers

    Science.gov (United States)

    Kenter, Almus; Kraft, Ralph; Gauron, Thomas; Murray, Stephen S.

    2014-07-01

    The Smithsonian Astrophysical Observatory (SAO) in collaboration with SRI/Sarnoff is developing monolithic CMOS detectors optimized for x-ray astronomy. The goal of this multi-year program is to produce CMOS x-ray imaging spectrometers that are Fano noise limited over the 0.1-10keV energy band while incorporating the many benefits of CMOS technology. These benefits include: low power consumption, radiation "hardness", high levels of integration, and very high read rates. Small format test devices from a previous wafer fabrication run (2011-2012) have recently been back-thinned and tested for response below 1keV. These devices perform as expected in regards to dark current, read noise, spectral response and Quantum Efficiency (QE). We demonstrate that running these devices at rates ~> 1Mpix/second eliminates the need for cooling as shot noise from any dark current is greatly mitigated. The test devices were fabricated on 15μm, high resistivity custom (~30kΩ-cm) epitaxial silicon and have a 16 by 192 pixel format. They incorporate 16μm pitch, 6 Transistor Pinned Photo Diode (6TPPD) pixels which have ~40μV/electron sensitivity and a highly parallel analog CDS signal chain. Newer, improved, lower noise detectors have just been fabricated (October 2013). These new detectors are fabricated on 9μm epitaxial silicon and have a 1k by 1k format. They incorporate similar 16μm pitch, 6TPPD pixels but have ~ 50% higher sensitivity and much (3×) lower read noise. These new detectors have undergone preliminary testing for functionality in Front Illuminated (FI) form and are presently being prepared for back thinning and packaging. Monolithic CMOS devices such as these, would be ideal candidate detectors for the focal planes of Solar, planetary and other space-borne x-ray astronomy missions. The high through-put, low noise and excellent low energy response, provide high dynamic range and good time resolution; bright, time varying x-ray features could be temporally and

  14. Application of X-ray CCD camera in X-ray spot diagnosis of rod-pinch diode

    International Nuclear Information System (INIS)

    Song Yan; Zhou Ming; Song Guzhou; Ma Jiming; Duan Baojun; Han Changcai; Yao Zhiming

    2015-01-01

    The pinhole imaging technique is widely used in the measurement of X-ray spot of rod-pinch diode. The X-ray CCD camera, which was composed of film, fiber optic taper and CCD camera, was employed to replace the imaging system based on scintillator, lens and CCD camera in the diagnosis of X-ray spot. The resolution of the X-ray CCD camera was studied. The resolution is restricted by the film and is 5 lp/mm in the test with Pb resolution chart. The frequency is 1.5 lp/mm when the MTF is 0.5 in the test with edge image. The resolution tests indicate that the X-ray CCD camera can meet the requirement of the diagnosis of X-ray spot whose scale is about 1.5 mm when the pinhole imaging magnification is 0.5. At last, the image of X-ray spot was gained and the restoration was implemented in the diagnosis of X-ray spot of rod-pinch diode. (authors)

  15. 78 FR 66039 - Modification of National Customs Automation Program Test Concerning Automated Commercial...

    Science.gov (United States)

    2013-11-04

    ... Customs Automation Program Test Concerning Automated Commercial Environment (ACE) Cargo Release (Formerly...) plan to both rename and modify the National Customs Automation Program (NCAP) test concerning the... data elements required to obtain release for cargo transported by air. The test will now be known as...

  16. Specialized software utilities for gamma ray spectrometry. Final report of a co-ordinated research project 1996-2000

    International Nuclear Information System (INIS)

    2002-03-01

    A Co-ordinated Research Project (CRP) on Software Utilities for Gamma Ray Spectrometry was initiated by the International Atomic Energy Agency in 1996 for a three year period. In the CRP several basic applications of nuclear data handling were assayed which also dealt with the development of PC computer codes for various spectrometric purposes. The CRP produced several software packages: for the analysis of low level NaI spectra; user controlled analysis of gamma ray spectra from HPGe detectors; a set of routines for the definition of the detector resolution function and for the unfolding of experimental annihilation spectra; a program for the generation of gamma ray libraries for specific applications; a program to calculate true coincidence corrections; a program to calculate full-energy peak efficiency calibration curve for homogenous cylindrical sample geometries including self-attenuation correction; and a program for the library driven analysis of gamma ray spectra and for the quantification of radionuclide content in samples. In addition, the CRP addressed problems of the analysis of naturally occurring radioactive soil material gamma ray spectra, questions of quality assurance and quality control in gamma ray spectrometry, and verification of the expert system SHAMAN for the analysis of air filter spectra obtained within the framework of the Comprehensive Nuclear Test Ban Treaty. This TECDOC contains 10 presentations delivered at the meeting with the description of the software developed. Each of the papers has been indexed separately

  17. Test Program for the Performance Analysis of DNS64 Servers

    Directory of Open Access Journals (Sweden)

    Gábor Lencse

    2015-09-01

    Full Text Available In our earlier research papers, bash shell scripts using the host Linux command were applied for testing the performance and stability of different DNS64 server imple­mentations. Because of their inefficiency, a small multi-threaded C/C++ program (named dns64perf was written which can directly send DNS AAAA record queries. After the introduction to the essential theoretical background about the structure of DNS messages and TCP/IP socket interface programming, the design decisions and implementation details of our DNS64 performance test program are disclosed. The efficiency of dns64perf is compared to that of the old method using bash shell scripts. The result is convincing: dns64perf can send at least 95 times more DNS AAAA record queries per second. The source code of dns64perf is published under the GNU GPLv3 license to support the work of other researchers in the field of testing the performance of DNS64 servers.

  18. 75 FR 38422 - Procedures for Transportation Workplace Drug and Alcohol Testing Programs

    Science.gov (United States)

    2010-07-02

    ... 2105-AD84 Procedures for Transportation Workplace Drug and Alcohol Testing Programs AGENCY: Office of..., 2011. DATES: This rule is effective July 2, 2010. FOR FURTHER INFORMATION CONTACT: For program issues... Federal Regulations, as follows: PART 40--PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING...

  19. Advance of the National Program of Radiological Protection and Safety for medical diagnostic with X-rays

    International Nuclear Information System (INIS)

    Verdejo S, M.

    1999-01-01

    The National Program of Radiological Protection and Safety for medical diagnostic with X-ray (Programa Nacional de Proteccion y Seguridad Radiologica para diagnostico medico con rayos X) was initiated in the General Direction of Environmental Health (Direccion General de Salud Ambiental) in 1995. Task coordinated with different dependences of the Public Sector in collaboration between the Secretary of Health (Secretaria de Salud), the National Commission of Nuclear Safety and Safeguards (Comision Nacional de Seguridad Nuclear y Salvaguardias) and, the National Institute of Nuclear Research (Instituto Nacional de Investigaciones Nucleares). The surveillance to the fulfilment of the standardization in matter of Radiological Protection and Safety in the medical diagnostic with X-rays has been obtained for an important advance in the Public sector and it has been arousing interest in the Private sector. (Author)

  20. Inmate must take HIV test if he wants to enroll in program.

    Science.gov (United States)

    1999-10-29

    An inmate cannot sue the Taylorville Correctional Center in Illinois under the Americans with Disabilities Act (ADA) for requiring an HIV test for enrollment in a prison program. [Name removed] wanted to participate in the prison's culinary arts program, but did not want to take the HIV test. The 7th U.S. Circuit Court of Appeals ruled that [name removed] was not a "qualified individual with a disability" and therefore could not sue under ADA. The policy justification for the HIV test, which is required of all inmates enrolling in the program, was not addressed by the court.

  1. Future research program on prompt γ-ray emission in nuclear fission

    Science.gov (United States)

    Oberstedt, S.; Billnert, R.; Hambsch, F.-J.; Lebois, M.; Oberstedt, A.; Wilson, J. N.

    2015-12-01

    In recent years the measurement of prompt fission γ-ray spectra (PFGS) has gained renewed interest, after about forty years since the first comprehensive studies of the reactions 235U(n th , f), 239Pu(n th ,f) and 252Cf(sf). The renaissance was initiated by requests for new values especially for γ-ray multiplicity and average total energy release per fission in neutron-induced fission of 235U and 239Pu. Both isotopes are considered the most important ones with respect to the modeling of innovative cores required for the Generation-IV reactors, the majority working with fast neutrons. During the last 5 years we have conducted a systematic study of spectral data for thermal-neutron-induced fission on 235U and 241Pu as well as for the spontaneous fission of 252Cf with unprecedented accuracy. From the new data we conclude that those reactions do not considerably contribute to the observed heat excess and suspect other reactions playing a significant role. Possible contributions may originate from fast-neutron-induced reactions on 238U, which is largely present in the fuel, or from γ-induced fission from neutron capture in the construction material. A first experiment campaign on prompt γ-ray emission from fast-neutron-induced fission on 235,238U was successfully performed in order to test our assumptions. In the following we attempt to summarize, what has been done in the field to date, and to motivate future measurement campaigns exploiting dedicated neutron and photon beams as well as upcoming highly efficient detector assemblies.

  2. A microcontroller application as X-ray machine's high voltage controller

    International Nuclear Information System (INIS)

    Wiranto Budi Santoso; Beny Syawaludin

    2010-01-01

    A micro controller application as x-ray machine's high voltage controller has been carried out. The purpose of this micro controller application is to give an accurate high voltage supply to the x-ray tube so that the x-ray machine could produce the result as expected. The micro controller based X-ray machine's high voltage controller receives an input voltage from the keypad. This input value is displayed in the LCD (Liquid Crystal Display) screen. Then micro controller uses this input data to drive a stepper motor. The stepper motor adjusts the high voltage auto transformer's output according to the input value. The micro controller is programmed using BASCOM-8051 compiler. The test results show that the stepper motor could rotate according to an input value (author)

  3. Interactive processing of x-ray diffraction maxima (exchange of experience)

    International Nuclear Information System (INIS)

    Zabolotnyi, V.A.; Moroz, E.M.

    1993-01-01

    A program package for primary processing of the curve of intensity of x-ray dispersion has been developed and tested within the framework of creating computer programs that are compatible with IBM/PC/XT/AT computers for calculation and modeling of randial distributions of atoms. The following calculations have been included in this package: determination of the positions of maxima; separation of the maxima; and calculation of the integral characteristics of components. This paper describes the main feature of the algorithm, which is the procedure for varying the form of components, each of which is represented as a sum of two Gaussians with differing half-width ad amplitude. Use of the described method of modeling of the x-ray diffraction maximum was found effective in most of the practically important cases. To illustrate the operation of the program the results of approximation of a pentaplet of quartz obtained in CuKα-radiation with 0.01 degrees scanning step and 20 sec build-up time (40 kV; 40 mA; HZG-4C) are presented. 3 refs., 2 figs., 1 tab

  4. Development of a computational program for treatment of texture data by the X-ray diffraction technique

    International Nuclear Information System (INIS)

    Galego, Eguiberto

    2004-01-01

    In this work it has been developed a computational program for treatment of texture data by the X-ray diffraction technique using pole figures. It has been applied the resolution method by spherical harmonical series expansion for cubic and hexagonal microscopic symmetry and orthorhombic macroscopic symmetry. For yielding the microscopic symmetries it has been necessary the implementation of algorithmic for calculation the spherical harmonic of specific surface. The generation of Legendre Polynomial, based on the experimental data in relation to a and β step angles, is execution in real time. In the introduction of data, the graphical representation of pole figure is drawn in stereo graphic projection, being possible to the analyst three dimensional (3D) visualization. An internal routine verify validity of the Miller indexes, being possible to analyst the correction. The program exhibit the possible corrections applied to experimental data: defocusing, background and orientation of lamination direction (β angle). The correction of the defocusing and background is the executed automatically based on the optic used in the X-ray equipment (Schulz geometric). It has been implemented a routine of graphic manipulation of the contour iso lines for generation of the orientation distribution function (ODF), with easy manipulation of the number of lines and colors. In the ODF graphic, with the action of the mouse cursor on any section, it is visualized the values of Euler angles (φ 1 , Φ, φ 2 ) and of the respective f(g) intensity. Concomitantly, there is 3D graphic visualization of the crystal position in relation to the rolling direction. There is the possibility of graphic visualization in 3D of any section of the ODF. It is also possible the graphic visualization of the texture fiber. This program was named Texture Analysis Program (TAP). (author)

  5. Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System

    Science.gov (United States)

    Kellogg, E.; Brissenden, R.; Flanagan, K.; Freeman, M.; Hughes, J.; Jones, M.; Ljungberg, M.; Mckinnon, P.; Podgorski, W.; Schwartz, D.

    1992-01-01

    Advanced X-ray Astrophysics Facility (AXAF) X-ray optics testing is conducted by VETA-I, which consists of six nested Wolter type I grazing-incidence mirrors; VETA's X-ray Detection System (VXDS) in turn measures the imaging properties of VETA-I, yielding FWHM and encircled energy of the X-ray image obtained, as well as its effective area. VXDS contains a high resolution microchannel plate imaging X-ray detector and a pinhole scanning system in front of proportional-counter detectors. VETA-I's X-ray optics departs from the AXAF flight configuration in that it uses a temporary holding fixture; its mirror elements are not cut to final length, and are not coated with the metal film used to maximize high-energy reflection.

  6. 40 CFR 91.803 - Manufacturer in-use testing program.

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES In-Use Testing and Recall... failing engine, two more engines shall be tested until the total number of engines equals ten (10). (2... the total number of engines equals ten (10). (3) If an engine family was certified using carry over...

  7. Restart Testing Program for piping following steam generator replacement at North Anna Unit 1

    International Nuclear Information System (INIS)

    Bain, R.A.; Bayer, R.K.

    1993-01-01

    In order to provide assurance that the effects of performing steam generator replacement (SGR) at North Anna unit 1 had no adverse impact on plant piping systems, a cold functional verification restart testing program was developed. This restart testing program was implemented in lieu of a hot functional testing program normally used during the initial startup of a nuclear plant. A review of North Anna plant-specific and generic U.S. Nuclear Regulatory Commission requirements for restart testing was performed to ensure that no mandatory hot functional testing was required. This was determined to be the case, and the development of a cold functional test program was initiated. The cold functional test had inherent advantages as compared to the hot functional testing, while still providing assurance of piping system adequacy. The advantages of the cold verification program included reducing risk to personnel from hot piping, increasing the accuracy of measurements with the improvement in work conditions, eliminating engineering activities during the heatup process, and being able to record measurements as construction work was completed allowing for rework or repair of components if required. To ensure the effectiveness of the cold verification program, a project procedure was generated to identify the personnel, equipment, and measurement requirements. An engineering calculation was issued to document the scope of the restart test program, and an additional calculation was developed to provide acceptance criteria for the critical commodity measurements

  8. 1/3-scale model testing program

    International Nuclear Information System (INIS)

    Yoshimura, H.R.; Attaway, S.W.; Bronowski, D.R.; Uncapher, W.L.; Huerta, M.; Abbott, D.G.

    1989-01-01

    This paper describes the drop testing of a one-third scale model transport cask system. Two casks were supplied by Transnuclear, Inc. (TN) to demonstrate dual purpose shipping/storage casks. These casks will be used to ship spent fuel from DOEs West Valley demonstration project in New York to the Idaho National Engineering Laboratory (INEL) for long term spent fuel dry storage demonstration. As part of the certification process, one-third scale model tests were performed to obtain experimental data. Two 9-m (30-ft) drop tests were conducted on a mass model of the cask body and scaled balsa and redwood filled impact limiters. In the first test, the cask system was tested in an end-on configuration. In the second test, the system was tested in a slap-down configuration where the axis of the cask was oriented at a 10 degree angle with the horizontal. Slap-down occurs for shallow angle drops where the primary impact at one end of the cask is followed by a secondary impact at the other end. The objectives of the testing program were to (1) obtain deceleration and displacement information for the cask and impact limiter system, (2) obtain dynamic force-displacement data for the impact limiters, (3) verify the integrity of the impact limiter retention system, and (4) examine the crush behavior of the limiters. This paper describes both test results in terms of measured deceleration, post test deformation measurements, and the general structural response of the system

  9. Safeguards system testing WSRC Insider Exercise Program (U)

    International Nuclear Information System (INIS)

    Robichaux, J.J.

    1991-01-01

    One of the major concerns related to the control and accountability of nuclear material located at DOE facilities is the theft or diversion of material by an insider. Many complex safeguards and security systems have been installed to provide timely detection and prevention of the removal of nuclear materials. The Westinghouse Savannah River Company's (WSRC) Material Control and Accountability (MC and A) section has implemented an insider exercise program designed to evaluate the effectiveness of these safeguards systems. Exercises consist of limited scope performance test. This paper describes the structure and controls for the insider exercise program at the Savannah River Site, the lessons learned over the past several years, and methods being utilized to improve the program

  10. Testing the Isotropic Universe Using the Gamma-Ray Burst Data of Fermi/GBM

    Science.gov (United States)

    Řípa, Jakub; Shafieloo, Arman

    2017-12-01

    The sky distribution of gamma-ray bursts (GRBs) has been intensively studied by various groups for more than two decades. Most of these studies test the isotropy of GRBs based on their sky number density distribution. In this work, we propose an approach to test the isotropy of the universe through inspecting the isotropy of the properties of GRBs such as their duration, fluences, and peak fluxes at various energy bands and different timescales. We apply this method on the Fermi/Gamma-ray Burst Monitor (GBM) data sample containing 1591 GRBs. The most noticeable feature we found is near the Galactic coordinates l≈ 30^\\circ , b≈ 15^\\circ , and radius r≈ 20^\\circ {--}40^\\circ . The inferred probability for the occurrence of such an anisotropic signal (in a random isotropic sample) is derived to be less than a percent in some of the tests while the other tests give results consistent with isotropy. These are based on the comparison of the results from the real data with the randomly shuffled data samples. Considering the large number of statistics we used in this work (some of which are correlated with each other), we can anticipate that the detected feature could be a result of statistical fluctuations. Moreover, we noticed a considerably low number of GRBs in this particular patch, which might be due to some instrumentation or observational effects that can consequently affect our statistics through some systematics. Further investigation is highly desirable in order to clarify this result, e.g., utilizing a larger future Fermi/GBM data sample as well as data samples of other GRB missions and also looking for possible systematics.

  11. A Study of Minimum Competency Testing Programs. Final Summary and Analysis Report.

    Science.gov (United States)

    Gorth, William Phillip; Perkins, Marcy R.

    To portray the status of minimum competency testing programs nationwide; as of June 30, 1979, on-site visits were conducted with directors of all 31 state programs and 20 local district programs. Most programs were developed since 1976; 14 state and 13 local programs are fully implemented. The state board of education mandated 16 state programs;…

  12. Energy spectrum analysis between single and dual energy source x-ray imaging for PCB non-destructive test

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyeong Jin; Kim, Myung Soo; Lee, Min Ju; Kang, Dong Uk; Lee, Dae Hee; Kim, Ye Won; Kim, Chan Kyu; Kim, Hyoung Taek; Kim, Gi Yoon; Cho, Gyu Seong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-08-15

    Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB nondestructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

  13. Energy spectrum analysis between single and dual energy source x-ray imaging for PCB non-destructive test

    International Nuclear Information System (INIS)

    Park, Kyeong Jin; Kim, Myung Soo; Lee, Min Ju; Kang, Dong Uk; Lee, Dae Hee; Kim, Ye Won; Kim, Chan Kyu; Kim, Hyoung Taek; Kim, Gi Yoon; Cho, Gyu Seong

    2015-01-01

    Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB nondestructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency

  14. LLNL X-ray Calibration and Standards Laboratory

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The LLNL X-ray Calibration and Standards Laboratory is a unique facility for developing and calibrating x-ray sources, detectors, and materials, and for conducting x-ray physics research in support of our weapon and fusion-energy programs

  15. 75 FR 54048 - Energy Efficiency Program: Test Procedure for Televisions; Request for Information and Request...

    Science.gov (United States)

    2010-09-03

    ... plasma, cathode ray tube (CRT), and locally dimmed LED-backlit LCD designs. As a result, it can be useful.... This may disadvantage Plasma TVs, and has proven to be unpredictable with LED models. Furthermore, the... by the electronic programming guide, monitoring for emergency messaging/ communications and/or...

  16. Spent fuel sabotage test program, characterization of aerosol dispersal : interim final report

    International Nuclear Information System (INIS)

    Gregson, Michael Warren; Brockmann, John E.; Loiseau, Olivier; Klennert, Lindsay A.; Nolte, Oliver; Molecke, Martin Alan; Autrusson, Bruno A.; Koch, Wolfgang; Pretzsch, Gunter Guido; Brucher, Wenzel; Steyskal, Michele D.

    2008-01-01

    This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program provides source-term data that are relevant to plausible sabotage scenarios in relation to spent fuel transport and storage casks and associated risk assessments. We present details and significant results obtained from this program from 2001 through 2007. Measured aerosol results include: respirable fractions produced; amounts, nuclide content, and produced particle size distributions and morphology; measurements of volatile fission product species enhanced sorption--enrichment factors onto respirable particles; and, status on determination of the spent fuel ratio, SFR, needed for scaling studies. Emphasis is provided on recent Phase 3 tests using depleted uranium oxide pellets plus non-radioactive fission product dopants in surrogate spent fuel test rodlets, plus the latest surrogate cerium oxide results and aerosol laboratory supporting calibration work. The DUO 2 , CeO 2 , plus fission product dopant aerosol particle results are compared with available historical data. We also provide a status review on continuing preparations for the final Phase 4 in this program, tests using individual short rodlets containing actual spent fuel from U.S. PWR reactors, with both high- and lower-burnup fuel. The source-term data, aerosol results, and program design have been tailored to support and guide follow-on computer modeling of aerosol dispersal hazards and radiological consequence assessments. This spent fuel sabotage, aerosol test program was performed primarily at Sandia National Laboratories, with support provided by both the U.S. Department of Energy and the Nuclear Regulatory Commission. This program has significant input from, and is cooperatively supported and

  17. Spent fuel sabotage test program, characterization of aerosol dispersal : interim final report.

    Energy Technology Data Exchange (ETDEWEB)

    Gregson, Michael Warren; Brockmann, John E.; Loiseau, Olivier (Institut de Radioprotection et de Surete Nucleaire, France); Klennert, Lindsay A.; Nolte, Oliver (Fraunhofer Institut fur Toxikologie und Experimentelle Medizin, Germany); Molecke, Martin Alan; Autrusson, Bruno A. (Institut de Radioprotection et de Surete Nucleaire, France); Koch, Wolfgang (Fraunhofer Institut fur Toxikologie und Experimentelle Medizin, Germany); Pretzsch, Gunter Guido (Gesellschaft fur Anlagen- und Reaktorsicherheit, Germany); Brucher, Wenzel (Gesellschaft fur Anlagen- und Reaktorsicherheit, Germany); Steyskal, Michele D.

    2008-03-01

    This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program provides source-term data that are relevant to plausible sabotage scenarios in relation to spent fuel transport and storage casks and associated risk assessments. We present details and significant results obtained from this program from 2001 through 2007. Measured aerosol results include: respirable fractions produced; amounts, nuclide content, and produced particle size distributions and morphology; measurements of volatile fission product species enhanced sorption--enrichment factors onto respirable particles; and, status on determination of the spent fuel ratio, SFR, needed for scaling studies. Emphasis is provided on recent Phase 3 tests using depleted uranium oxide pellets plus non-radioactive fission product dopants in surrogate spent fuel test rodlets, plus the latest surrogate cerium oxide results and aerosol laboratory supporting calibration work. The DUO{sub 2}, CeO{sub 2}, plus fission product dopant aerosol particle results are compared with available historical data. We also provide a status review on continuing preparations for the final Phase 4 in this program, tests using individual short rodlets containing actual spent fuel from U.S. PWR reactors, with both high- and lower-burnup fuel. The source-term data, aerosol results, and program design have been tailored to support and guide follow-on computer modeling of aerosol dispersal hazards and radiological consequence assessments. This spent fuel sabotage, aerosol test program was performed primarily at Sandia National Laboratories, with support provided by both the U.S. Department of Energy and the Nuclear Regulatory Commission. This program has significant input from, and is cooperatively

  18. X-rays for industry: Non-destructive testing helps Malaysia’s competitiveness

    International Nuclear Information System (INIS)

    Plonsky, Brian

    2015-01-01

    Industrial testing using nuclear technology has contributed to the competitiveness of Malaysia’s manufacturing sector, industry players have said. The country has also built itself an export niche in South-East Asia, offering non-destructive testing (NDT) with nuclear devices to manufacturers in neighbouring countries. “The fact that we can get NDT services of a good quality level at a very reasonable price allows us to spend more money on inspection, and thus improve our competitiveness as well as the level of safety of our plant,” said Zamaludin Ali, senior engineer at oil company PETRONAS. Before the development of a local NDT industry and accreditation system for testing services, PETRONAS and other companies in Malaysia had to rely on foreign NDT providers, or local companies hiring operators certified abroad, he explained. NDT using nuclear techniques involves the use of ionizing radiation to test the quality of finished products. It is based on the same principle as X-rays used in hospitals. Oil pipes, boilers, pressure vessels, aircraft equipment and ships are among the products whose quality is tested with the technique. The IAEA has played an important role in helping Malaysia to establish accredited training agencies and a certification system, and to promote NDT technologies such as radiographic testing. As a result of this longstanding partnership, over 50 companies in Malaysia, employing more than 2000 technicians, are certified to carry out NDT testing.

  19. Standard test method for nondestructive assay of special nuclear material in low density scrap and waste by segmented passive gamma-Ray scanning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the transmission-corrected nondestructive assay (NDA) of gamma-ray emitting special nuclear materials (SNMs), most commonly 235U, 239Pu, and 241Am, in low-density scrap or waste, packaged in cylindrical containers. The method can also be applied to NDA of other gamma-emitting nuclides including fission products. High-resolution gamma-ray spectroscopy is used to detect and measure the nuclides of interest and to measure and correct for gamma-ray attenuation in a series of horizontal segments (collimated gamma detector views) of the container. Corrections are also made for counting losses occasioned by signal processing limitations (1-3). 1.2 There are currently several systems in use or under development for determining the attenuation corrections for NDA of radioisotopic materials (4-8). A related technique, tomographic gamma-ray scanning (TGS), is not included in this test method (9, 10, 11). 1.2.1 This test method will cover two implementations of the Segmented Gamma Scanning ...

  20. X-ray study of a test quadrant of the SODART telescopes using the expanded beam x-ray optics facility at the Daresbury synchrotron

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Frederiksen, P.

    1994-01-01

    The imaging properties of a test model of the SODART telescopes have been studied using an expanded beam X-ray facility at the Daresbury synchrotron. The encircled power and the point spread function at three energies 6.627 keV, 8.837 keV and 11.046 keV have been measured using 1D and 2D position...

  1. The research on x-ray nondestructive testing and image processing technology of explosive components

    International Nuclear Information System (INIS)

    Shi, C.; Zhai, X.; Liu, Z.; Lin, H.

    2004-01-01

    The explosive components will inevitably produce defects such as impurity, crack and degumming during production and storage, therefore the inside substance of the explosive components must be examined and the findings concerned must be identified and estimated in order to ensure the quality and service life of the explosive components. Firstly, some analyses are conducted on the usual X-ray NDT system theory, and the simulation explosive component is made with some pre-built defects such as debonding, cracks, blow holes, impurities, and non-uniform density. The image testing system most fit for the explosive components is established. Secondly, the ways of X-ray digital image processing are discussed; the obtained images are enhanced and restored through the self-accommodating build-up arithmetic and proper restoring methods. By means of the results of the overall comparison and analysis of the digital image processing technology, it is clearly indicated that it is feasible to use X-ray digital-imaging ways to carry out the NDT of explosive components and identify the inside defects. (author)

  2. Gamma ray astronomy and the origin of galactic cosmic rays

    International Nuclear Information System (INIS)

    Gabici, Stefano

    2011-01-01

    Diffusive shock acceleration operating at expanding supernova remnant shells is by far the most popular model for the origin of galactic cosmic rays. Despite the general consensus received by the model, an unambiguous and conclusive proof of the supernova remnant hypothesis is still missing. In this context, the recent developments in gamma ray astronomy provide us with precious insights into the problem of the origin of galactic cosmic rays, since production of gamma rays is expected both during the acceleration of cosmic rays at supernova remnant shocks and during their subsequent propagation in the interstellar medium. In particular, the recent detection of a number of supernova remnants at TeV energies nicely fits with the model, but it still does not constitute a conclusive proof of it, mainly due to the difficulty of disentangling the hadronic and leptonic contributions to the observed gamma ray emission. The main goal of my research is to search for an unambiguous and conclusive observational test for proving (or disproving) the idea that supernova remnants are the sources of galactic cosmic rays with energies up to (at least) the cosmic ray knee. Our present comprehension of the mechanisms of particle acceleration at shocks and of the propagation of cosmic rays in turbulent magnetic fields encourages beliefs that such a conclusive test might come from future observations of supernova remnants and of the Galaxy in the almost unexplored domain of multi-TeV gamma rays. (author)

  3. Gamma ray shielding study of barium-bismuth-borosilicate glasses as transparent shielding materials using MCNP-4C code, XCOM program, and available experimental data

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Reza; Yousefinia, Hassan [Nuclear Fuel Cycle Research School (NFCRS), Nuclear Science and Technology Research Institute (NSTRI), Atomic Energy Organization of Iran, Tehran (Iran, Islamic Republic of); Moghaddam, Alireza Khorrami [Radiology Department, Paramedical Faculty, Mazandaran University of Medical Sciences, Sari (Iran, Islamic Republic of)

    2017-02-15

    In this work, linear and mass attenuation coefficients, effective atomic number and electron density, mean free paths, and half value layer and 10th value layer values of barium-bismuth-borosilicate glasses were obtained for 662 keV, 1,173 keV, and 1,332 keV gamma ray energies using MCNP-4C code and XCOM program. Then obtained data were compared with available experimental data. The MCNP-4C code and XCOM program results were in good agreement with the experimental data. Barium-bismuth-borosilicate glasses have good gamma ray shielding properties from the shielding point of view.

  4. New X-ray testing methods of aerosol products for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bozydar Knyziak, Adrian, E-mail: a.knyziak@gum.gov.pl; Rzodkiewicz, Witold, E-mail: w.rzodkiewicz@gum.gov.pl; Kaczorowska, Ewa, E-mail: e.kaczorowska@gum.gov.pl; Derlacinski, Michal, E-mail: m.derlacinski@gum.gov.pl

    2017-02-01

    An amount of product in e.g. an aerosol canister is not difficult to estimate by weighing a filled can and subtracting the tare of packaging. In this way, we can obtain the net weight of the ingredients present in the can. Although, this does not indicate the volumetric content. Therefore, in the paper, the fundamental (the weight method and given by FEICA) and new methods (given by authors) related to the determination of the volumetric content of canister filled with aeorosol products are presented. The new methods are based on direct digital radiography (DR) using X-ray radiation. For the needs of new methods, the X-ray CCD-DR imaging system was built and developed in our Laboratory in Department of Radiation and Vibration at the Central Office of Measures. For comparison purposes, with regard to the volumetric content, a lot of metal cans of capacities 140, 185, 450, 700 ml were inspected. In future, computed tomography (CT) for industrial radiography in our laboratory will be used. Currently, an algorithm for CT is being tested. It will give us possibility for very precise measurements to determine volumetric content of examined canisters.

  5. Japanese contributions to ITER testing program of solid breeder blankets for DEMO

    International Nuclear Information System (INIS)

    Kuroda, Toshimasa; Yoshida, Hiroshi; Takatsu, Hideyuki; Maki, Koichi; Mori, Seiji; Kobayashi, Takeshi; Suzuki, Tatsushi; Hirata, Shingo; Miura, Hidenori.

    1991-04-01

    ITER Conceptual Design Activity (CDA), which has been conducted by four parties (Japan, EC, USA and USSR) since May 1988, has been finished on December 1990 with a great achievement of international design work of the integrated fusion experimental reactor. Numerous issues of physics and technology have been clarified for providing a framework of the next phase of ITER (Engineering Design Activity; EDA). Establishment of an ITER testing program, which includes technical test issues of neutronics, solid breeder blankets, liquid breeder blankets, plasma facing components, and materials, has been one of the goals of the CDA. This report describes Japanese proposal for the testing program of DEMO/power reactor blanket development. For two concepts of solid breeder blanket (helium-cooled and water-cooled), identification of technical issues, scheduling of test program, and conceptual design of test modules including required test facility such as cooling and tritium recovery systems have been carried out as the Japanese contribution to the CDA. (author)

  6. Physical Education Experimental Program to Test the Effect on Perceived Competence

    Directory of Open Access Journals (Sweden)

    Edin Brankovic

    2017-06-01

    Full Text Available The first purpose of this study was to test effect of multidisciplinary and holistic experimental program (EP in physical education program effect on the soul need perceived competence. The second purpose of this study was to analyse the relationship between attitudes of perceived competence in the experimental group before and after the application of program, mostly due the theoretical reason that perceived competence is predictor of Flow. The data was collected from 74 students of the 8th grade of elementary schools randomly divided in two groups (experimental: 53; control: 21. The system of variables consisted of perceived competence scale items. The t-test analysis was applied to test perceived competence attitudes before and after the EP. The experimental group attitudes of perceived competence after the EP were significantly more positive than before participation in it, while control group attitudes of perceived competence decreased after participation in the regular school program. The current findings support the authors’ hypothesis that the holistic program has significant effect on the soul need perceived competence which is closest predictor of Flow. This study applied multidisciplinary EP which was designed on growth-mind set practices and sparks findings–both connected to flow experience and intrinsic motivation–to suggest future comprehensive program that could be potentially used as a regular tool for achieving both, Flow and intrinsic motivation. Findings with certainty provide a basis for future necessary qualitative research of the program effects on the intrinsic motivation.

  7. Tests for radiation protection in X-Ray mammography room for professional and non-professional exposure

    International Nuclear Information System (INIS)

    Naidenov, I.; Skocheva, A.

    2006-01-01

    Full text: Control tests for radiation protection of medical diagnostic rooms in our country are based on the guidelines to the use of x-rays in medicine and on the basic safety standards for radiation protection. The mammography room tests are not supported by basic data (such as normal conditions for testing and secondary limits) which to allow the developing of methods as the case is with the conventional x-ray rooms. The material presents and discusses over the situation of the matter with the aim to find solution of the problem. In mammography units the space distribution of the dose field of the object scattering radiation is not symmetrical, the maximum being in a direction opposite to the primary beam. Control tests were made for stray radiation in major (in the plane of beam rotation) test points in five rooms with mammography units of different producers and generation, under angles of scattering from the direction of the beam of 900 (horizontal table - 0 deg projection) and 1630 (tilt table - 730 deg projection). The results on the stray radiation show up to four times higher values in the 730 projection, the remaining conditions being the same. Normalization to the week loading used in the shielding design, like the comparison with secondary limits as published in the available norms do not give unambiguous idea. It is advisable to use this projection in control tests for radiation protection and the values shall be compared with the secondary limits of the corresponding standard loading

  8. High energy physics in cosmic rays

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Lawrence W. [University of Michigan, Ann Arbor, Michigan (United States)

    2013-02-07

    In the first half-century of cosmic ray physics, the primary research focus was on elementary particles; the positron, pi-mesons, mu-mesons, and hyperons were discovered in cosmic rays. Much of this research was carried out at mountain elevations; Pic du Midi in the Pyrenees, Mt. Chacaltaya in Bolivia, and Mt. Evans/Echo Lake in Colorado, among other sites. In the 1960s, claims of the observation of free quarks, and satellite measurements of a significant rise in p-p cross sections, plus the delay in initiating accelerator construction programs for energies above 100 GeV, motivated the Michigan-Wisconsin group to undertake a serious cosmic ray program at Echo Lake. Subsequently, with the succession of higher energy accelerators and colliders at CERN and Fermilab, cosmic ray research has increasingly focused on cosmology and astrophysics, although some groups continue to study cosmic ray particle interactions in emulsion chambers.

  9. Radiation detection technology assessment program (RADTAP)

    International Nuclear Information System (INIS)

    Smith, D.E.

    1998-01-01

    The U.S. Customs Service and the U.S. Department of Energy (DOE) conducted a technical and operational assessment of gamma ray radiation detection equipment during the period May 5-16, 1997 at a testing facility in North Carolina. The effort was entitled, ''Radiation Detection Technology Assessment Program (RADTAP)'', and was conducted for the purpose of assessing the applicability, sensitivity and robustness of a diverse suite of gamma ray detection and identification equipment for possible use by Customs and other law enforcement agencies. Thirteen companies entered 25 instruments into the assessment program. All detection equipment entered had to exhibit a minimum sensitivity of 20 micro-R per hour (background included) from a Cesium-137 point source. Isotope identifying spectrometers entered were man portable and operable at room temperature with read-out that could be interpreted by non-technical personnel. Radioactive sources used in the assessment included special nuclear material, industrial and health isotopes. Evaluators included Customs inspectors and technical experts from DOE and Customs. No conclusions or recommendations were issued based on the quantitative and qualitative test results, however, the results of the program provided law enforcement agencies with the necessary data to select equipment that best meets their operational needs and budgets. (author)

  10. 77 FR 36014 - Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors

    Science.gov (United States)

    2012-06-15

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling... for public comment draft regulatory guide (DG), DG-1277, ``Initial Test Program of Emergency Core..., entitled, ``Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors,'' is...

  11. 78 FR 27984 - Modification of the National Customs Automation Program Test (NCAP) Regarding Reconciliation for...

    Science.gov (United States)

    2013-05-13

    ... Customs Automation Program Test (NCAP) Regarding Reconciliation for Filing Certain Post-Importation Claims... Automation Program (NCAP) Reconciliation prototype test to include the filing of post-importation [[Page... of the Test Reconciliation, a planned component of the National Customs Automation Program (NCAP), as...

  12. Test Report Emission Test Program EPA Information Collection Request for Delayed Coking Units 736 Coker Unit

    Science.gov (United States)

    ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.

  13. An Airborne Parachute Compartment Test Bed for the Orion Parachute Test Program

    Science.gov (United States)

    Moore, James W.; Romero, Leah M.

    2013-01-01

    The test program developing parachutes for the Orion/MPCV includes drop tests with parachutes deployed from an Orion-like parachute compartment at a wide range of dynamic pressures. Aircraft and altitude constraints precluded the use of an Orion boilerplate capsule for several test points. Therefore, a dart-shaped test vehicle with a hi-fidelity mock-up of the Orion parachute compartment has been developed. The available aircraft options imposed constraints on the test vehicle development and concept of operations. Delivery of this test vehicle to the desired velocity, altitude, and orientation required for the test is a di cult problem involving multiple engineering disciplines. This paper describes the development of the test technique. The engineering challenges include extraction from an aircraft, reposition of the extraction parachute, and mid-air separation of two vehicles, neither of which has an active attitude control system. The desired separation behavior is achieved by precisely controlling the release point using on-board monitoring of the motion. The design of the test vehicle is also described. The trajectory simulations and other analyses used to develop this technique and predict the behavior of the test vehicle are reviewed in detail. The application of the technique on several successful drop tests is summarized.

  14. Justice downwind: America's atomic testing program in the 1950s

    International Nuclear Information System (INIS)

    Ball, H.

    1986-01-01

    Drawing on personal interviews, case histories, and the archives of the Atomic Energy Commission, Professor Ball discusses the American nuclear-testing program from 1951 to 1963, the impact of the testing on people living downwind from the Nevada Test Site, long-term effects of radiation exposure, and the clash between the ''downwinders'' and the government

  15. 75 FR 3153 - Drug and Alcohol Testing Program; Correction

    Science.gov (United States)

    2010-01-20

    ... definition of prohibited drugs. In Sec. Sec. 120.103 and 120.211, we omitted the reference to Sec. 135.1 from.... FAA-2008-0937; Amendment No. 120-0A, 135-117A] RIN 2120-AJ37 Drug and Alcohol Testing Program... Aviation Administration (FAA) is correcting its drug and alcohol testing regulations published on May 14...

  16. Cosmic-ray-veto detector system

    International Nuclear Information System (INIS)

    Miller, D.W.; Menlove, H.O.

    1992-12-01

    To reduce the cosmic-ray-induced neutron background, we are testing a cosmic-ray veto option with a neutron detector system that uses plastic scintillator slabs mounted on the outside of a 3 He-tube detector. The scintillator slabs eliminate unwanted cosmic-ray events, enabling the detector to assay low-level plutonium samples, for which a low-background coincident signature is critical. This report describes the design and testing of the prototype cosmic-ray-veto detector system

  17. History and Benefits of Engine Level Testing Throughout the Space Shuttle Main Engine Program

    Science.gov (United States)

    VanHooser, Katherine; Kan, Kenneth; Maddux, Lewis; Runkle, Everett

    2010-01-01

    Rocket engine testing is important throughout a program s life and is essential to the overall success of the program. Space Shuttle Main Engine (SSME) testing can be divided into three phases: development, certification, and operational. Development tests are conducted on the basic design and are used to develop safe start and shutdown transients and to demonstrate mainstage operation. This phase helps form the foundation of the program, demands navigation of a very steep learning curve, and yields results that shape the final engine design. Certification testing involves multiple engine samples and more aggressive test profiles that explore the boundaries of the engine to vehicle interface requirements. The hardware being tested may have evolved slightly from that in the development phase. Operational testing is conducted with mature hardware and includes acceptance testing of flight assets, resolving anomalies that occur in flight, continuing to expand the performance envelope, and implementing design upgrades. This paper will examine these phases of testing and their importance to the SSME program. Examples of tests conducted in each phase will also be presented.

  18. An Algorithm of an X-ray Hit Allocation to a Single Pixel in a Cluster and Its Test-Circuit Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Deptuch, G. W. [AGH-UST, Cracow; Fahim, F. [Fermilab; Grybos, P. [AGH-UST, Cracow; Hoff, J. [Fermilab; Maj, P. [AGH-UST, Cracow; Siddons, D. P. [Brookhaven; Kmon, P. [AGH-UST, Cracow; Trimpl, M. [Fermilab; Zimmerman, T. [Fermilab

    2017-05-06

    An on-chip implementable algorithm for allocation of an X-ray photon imprint, called a hit, to a single pixel in the presence of charge sharing in a highly segmented pixel detector is described. Its proof-of-principle implementation is also given supported by the results of tests using a highly collimated X-ray photon beam from a synchrotron source. The algorithm handles asynchronous arrivals of X-ray photons. Activation of groups of pixels, comparisons of peak amplitudes of pulses within an active neighborhood and finally latching of the results of these comparisons constitute the three procedural steps of the algorithm. A grouping of pixels to one virtual pixel that recovers composite signals and event driven strobes to control comparisons of fractional signals between neighboring pixels are the actuators of the algorithm. The circuitry necessary to implement the algorithm requires an extensive inter-pixel connection grid of analog and digital signals that are exchanged between pixels. A test-circuit implementation of the algorithm was achieved with a small array of 32×32 pixels and the device was exposed to an 8 keV highly collimated to a diameter of 3 μm X-ray beam. The results of these tests are given in the paper assessing physical implementation of the algorithm.

  19. PWR blowdown heat transfer separate-effects program: Thermal-Hydraulic Test Facility experimental data report for test 100

    International Nuclear Information System (INIS)

    White, M.D.; Hedrick, R.A.

    1977-01-01

    Reduced instrument responses are presented for Thermal-Hydraulic Test Facility (THTF) test 100, which is part of the ORNL Pressurized-Water-Reactor (PWR) Blowdown Heat Transfer Separate-Effects Program. The objective of the program is to investigate the thermal-hydraulic phenomenon governing the energy transfer and transport processes that occur during a loss-of-coolant accident in a PWR system. Test 100 was conducted to investigate the response of heater rod bundle 1 and instrumented spool pieces with flow homogenizing screens to a double-ended rupture with equal break areas at the test section inlet and outlet. The primary purpose of this report is to make the reduced instrument responses during test 100 available. The responses are presented in graphical form in engineering units and have been analyzed only to the extent necessary to assure reasonableness and consistency

  20. Simulation study on the behavior of X-rays and gamma rays in an inhomogeneous medium using the Monte Carlo technique

    International Nuclear Information System (INIS)

    Murase, Kenya; Kataoka, Masaaki; Kawamura, Masashi; Tamada, Shuji; Hamamoto, Ken

    1989-01-01

    A computer program based on the Monte Carlo technique was developed for the analysis of the behavior of X-rays and gamma rays in an inhomogeneous medium. The statistical weight of a photon was introduced and the survival biasing method was used for reducing the statistical error. This computer program has the mass energy absorption and attenuation coefficients for 69 tissues and organs as a database file, and can be applied to various cases of inhomogeneity. The simulation and experimental results of the central axis percent-depth dose in an inhomogeneous phantom were in good agreement. This computer program will be useful for analysis on the behavior of X-rays and gamma rays in an inhomogeneous medium consisting of various tissues and organs, not only in radiotherapy treatment planning but also in diagnostic radiology and in the field treating radiation protection. (author)

  1. Modeling a forced to natural convection boiling test with the program LOOP-W

    International Nuclear Information System (INIS)

    Carbajo, J.J.

    1984-01-01

    Extensive testing has been conducted in the Simulant Boiling Flow Visualization (SBFV) loop in which water is boiled in a vertical transparent tube by circulating hot glycerine in an annulus surrounding the tube. Tests ranged from nonboiling forced convection to oscillatory boiling natural convection. The program LOOP-W has been developed to analyze these tests. This program is a multi-leg, one-dimensional, two-phase equilibrium model with slip between the phases. In this study, a specific test, performed at low power where non-boiling forced convection was changed to boiling natural convection and then to non-boiling again, has been modeled with the program LOOP-W

  2. Future research program on prompt γ-ray emission in nuclear fission

    Energy Technology Data Exchange (ETDEWEB)

    Oberstedt, S.; Hambsch, F.J. [Joint Research Centre IRMM, European Commission, Geel (Belgium); Billnert, R. [Joint Research Centre IRMM, European Commission, Geel (Belgium); Chalmers Tekniska Hoegskola, Fundamental Fysik, Goeteborg (Sweden); Lebois, M.; Wilson, J.N. [Institut de Physique Nucleaire Orsay, Orsay (France); Oberstedt, A. [Chalmers Tekniska Hoegskola, Fundamental Fysik, Goeteborg (Sweden); Ossolution Consulting, Oerebro (Sweden)

    2015-12-15

    In recent years the measurement of prompt fission γ-ray spectra (PFGS) has gained renewed interest, after about forty years since the first comprehensive studies of the reactions {sup 235}U(n{sub th}, f), {sup 239}Pu(n{sub th},f) and {sup 252}Cf(sf). The renaissance was initiated by requests for new values especially for γ-ray multiplicity and average total energy release per fission in neutron-induced fission of {sup 235}U and {sup 239}Pu. Both isotopes are considered the most important ones with respect to the modeling of innovative cores required for the Generation-IV reactors, the majority working with fast neutrons. During the last 5 years we have conducted a systematic study of spectral data for thermal-neutron-induced fission on {sup 235}U and {sup 241}Pu as well as for the spontaneous fission of {sup 252}Cf with unprecedented accuracy. From the new data we conclude that those reactions do not considerably contribute to the observed heat excess and suspect other reactions playing a significant role. Possible contributions may originate from fast-neutron-induced reactions on {sup 238}U, which is largely present in the fuel, or from γ-induced fission from neutron capture in the construction material. A first experiment campaign on prompt γ-ray emission from fast-neutron-induced fission on {sup 235,238}U was successfully performed in order to test our assumptions. In the following we attempt to summarize, what has been done in the field to date, and to motivate future measurement campaigns exploiting dedicated neutron and photon beams as well as upcoming highly efficient detector assemblies. (orig.)

  3. X-ray determination of charge states of ions moving in solids

    International Nuclear Information System (INIS)

    Fortner, R.J.; Matthews, D.L.

    1974-02-01

    The first part of this work discusses previous measurements of x-ray spectra and thick-target yields for Ar ions moving in solid graphite targets. These data are strongly affected by ''solid target effects.'' There are some rather serious limitations in the above measurements. This proposal solicits funds to expand the program to eliminate the limitations. The second part of the proposal contains a more detailed presentation of three types of measurements. These involve the extension of work to other collision systems, the development of an Auger electron spectrometer, and the use of a 7-m grazing-incidence spectrograph for x-ray spectroscopy. These measurements will enable testing of current pictures describing ions moving in solids and shed light on the feasibility of producing a beam of ions which could give rise to amplified stimulated x-ray emission (x-ray laser). (11 figures) (U.S.)

  4. Nuclear systems and testing programs for ITER. Progress report for FY 1998

    International Nuclear Information System (INIS)

    1998-01-01

    The effort during this performance period focused on a number of TBWG activities (including test module design and analysis) that were identified and agreed upon (in the presence of the ITER Director and Deputy Director) at TBWG-4. These include: (a) DEMO test module design and performance analysis under pulsed operation; (b) Test program operation plan; (c) Test port design and analysis; (d) Decay heat calculations and safety analysis; (e) Further discussion among the parties to define collaboratory on R and D for the test program as well as possible collaboration on the construction and operation of test articles; (f) Remote handling and ancillary equipment; (g) Criteria for qualifying a blanket module or submodule for actual insertion and testing in ITER; (h) Definition of test module instrumentation and verification of capability to perform in the ITER fusion environment (magnetic field, radiation, heating, etc.); and (i) Analysis to show that the results to be obtained from the test modules as designed can be extrapolated to DEMO and reactor conditions (e.g., higher wall loads and the need to demonstrate tritium self-sufficiency). The main achievements during this performance period include: (1) updating and finalizing the US DDDs for the ITER Blanket Program to form part of the ITER Final Design Report (FDR). Specific revisions were in response to the minimal lithium volume test blanket design requirements and safety impact and (2) evaluating the feasibility of the US test program, including instrumentation and the benefits of the ITER test program. Details of this assessment, including solid breeder and liquid breeder blanket test plans, are documented in UCLA-IFNT-13 (attached). In addition, dose mapping calculations were performed for the ITER Building, including equipment and layout of coolant pipes/heat exchangers. A report on ITER Building dose calculations was sent to UD ITER management and to the Garching Task Coordinator in April, 1998. The report

  5. Nondestructive exploratory tests of corrosion of steels embedded in cement-paste and mortar by the use of γ-ray

    International Nuclear Information System (INIS)

    Sekine, Isao; Yuasa, Makoto; Hotta, Akihiko

    1992-01-01

    Nondestructive exploratory test of corrosion of steels embedded in cement paste and mortar was carried out by the method based on γ-ray back-scattering. The possibility of such test was investigated with the theoretical calculation. From these results of the test, the difference (ΔD) of back-scattering dose rate of corroded and uncorroded specimens of bare-steels or cement paste- and mortar-embedded-steels was found and increased with angle (ω) of Compton scattering. A relationship between ΔD and ω was observed. The relation of ΔD with ω by the test corresponded to that by the theoretical calculation. For the steels embedded in cement paste and mortar, the value of ΔD decreased and became irregular depending upon i) the thickness and component of cover and ii) the shape of steel. The subject in future will be the investigation for a method of the exploratory test by γ-ray back-scattering by consideration of above environmental conditions. (author)

  6. Mathematical-programming approaches to test item pool design

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; van der Linden, Willem J.; Ariel, A.

    2002-01-01

    This paper presents an approach to item pool design that has the potential to improve on the quality of current item pools in educational and psychological testing andhence to increase both measurement precision and validity. The approach consists of the application of mathematical programming

  7. Application of gamma-ray radiography and gravimetric measurements after accelerated corrosion tests of steel embedded in mortar

    Energy Technology Data Exchange (ETDEWEB)

    Duffó, Gustavo, E-mail: duffo@cnea.gov.ar [Comisión Nacional de Energía Atómica, Gerencia Materiales, Depto. Corrosión, Av. Gral. Paz 1499, 1650 San Martín, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Av. Rivadavia 1917, 1033 Buenos Aires (Argentina); Universidad Nacional de San Martín, Av. Gral. Paz 1499, 1650 San Martín, Buenos Aires (Argentina); Gaillard, Natalia [Universidad Nacional de San Martín, Av. Gral. Paz 1499, 1650 San Martín, Buenos Aires (Argentina); Mariscotti, Mario; Ruffolo, Marcelo [Tomografía de Hormigón Armado S.A. (THASA), Reclus 2017, 1609 Boulogne, Buenos Aires (Argentina)

    2015-08-15

    The accelerated corrosion by the impressed current technique is widely used in studies of concrete durability since it has the advantage that tests can be carried out within reasonable periods of time. In the present work the relationship between the applied current density and the resulting damage on the reinforcing steel, by applying optical microscopy, scanning electron microscopy, gamma-ray radiography and gravimetric measurements, was studied by means of the implementation of accelerated corrosion tests on reinforced mortar. The results show that the efficiency of the applied current is between 1 and 77%, regardless of the applied current density, the water/cement ratio and the mortar cover depth of the specimens. The results show the applicability of the gamma-ray radiography technique to detect localized corrosion of steel rebars in laboratory specimens.

  8. LAB3 Cosmic Ray Test Stand Analysis of Steel Stack Supports

    International Nuclear Information System (INIS)

    Cease, H.

    1998-01-01

    A cosmic ray test stand is being constructed at Lab 3. The stand consists of two stacks of steel plates one resting on top of the other. The top stack is composed of 6 plates of steel making an overall stack size of 34.5-inch x 40-inch x 99-inch. The bottom stack also has 6 layers of plate making an overall size of approximately 49.5-inch x 82-inch x 99-inch. The bottom stack is supported with three support legs. See drawing 3823.000ME-900428 for the individual plate orientation. The minimum support leg size and necessary welds between plates are determined.

  9. Analysis of KC-46 Live-Fire Risk Mitigation Program Testing

    Science.gov (United States)

    2012-03-01

    the use of real hardware such as electrohydraulic actuators , electrical units, and converter regulators (Andrus, 2010). The only feasible method for...worked with the MQ-9 as a test engineer and analyst for the programs IOT &E, RQ-4 as lead engineer and program lead for the block 3 and the block 4

  10. ENDIX. A computer program to simulate energy dispersive X-ray and synchrotron powder diffraction diagrams

    International Nuclear Information System (INIS)

    Hovestreydt, E.; Karlsruhe Univ.; Parthe, E.; Benedict, U.

    1987-01-01

    A Fortran 77 computer program is described which allows the simulation of energy dispersive X-ray and synchrotron powder diffraction diagrams. The input consists of structural data (space group, unit cell dimensions, atomic positional and displacement parameters) and information on the experimental conditions (chosen Bragg angle, type of X-ray tube and applied voltage or operating power of synchrotron radiation source). The output consists of the normalized intensities of the diffraction lines, listed by increasing energy (in keV), and of an optional intensity-energy plot. The intensities are calculated with due consideration of the wave-length dependence of both the anomalous dispersion and the absorption coefficients. For a better agreement between observed and calculated spectra provision is made to optionally superimpose, on the calculated diffraction line spectrum, all additional lines such as fluorescence and emission lines and escape peaks. The different effects which have been considered in the simulation are discussed in some detail. A sample calculation of the energy dispersive powder diffraction pattern of UPt 3 (Ni 3 Sn structure type) is given. Warning: the user of ENDIX should be aware that for a successful application it is necessary to adapt the program to correspond to the actual experimental conditions. Even then, due to the only approximately known values of certain functions, the agreement between observed and calculated intensities will not be as good as for angle dispersive diffraction methods

  11. X-RAYS SEPARATOR: FORWARD STEP IN TECHNOLOGY OF OPTICAL SEPARATION

    Directory of Open Access Journals (Sweden)

    N. N. Potrakhov

    2017-01-01

    Full Text Available Presently the X-ray separation is used not only for research program, but it is also elaborated and applied for different sectors of economy. The seeds as biological objects that possess the complicated microstructure are very difficult to be exanimated by x-ray technology. The application of x-rays and further elaboration of optical  separators, principle  of action, basic specifications, way of their use and their efficiency was shown in the article. The x-ray separator may distinguish all hidden seed defects as it was described by a programmer, where owing to the use of the optical separating block in visual range it is possible to add some more details as a shape, brightness and a color of object surface being exanimated. The elaboration of such separation equipment is scientifically hard work requiring time and expenses. Last year researchers of ‘LETI’ developed the working model of industrial x-ray separator for examination of grains and nuts in different crops. This model was made on the basis of photoseparator F-5 manufactured at OAO ‘Voronezhselmash’. The instrument state and its mechanism operation are highlighted on monitor. In the regime of processing (separation and examination of each controlled batch, the passport is produced with  following  information on identification  code,  time of material receiving, time of test passed, number of grains or seeds tested. The code of receiver of material is given to each of established characteristics when working the regime of separation, determination of number of objects with characteristics tested and number of unidentified objects. The application of x-ray separators constructed on the basis of photoseparator F-5 enables to carry out the complex estimation on seed quality and separation in only instrument with the development of electronic protocol with many characteristics.

  12. X-ray diffraction imaging of material microstructures

    KAUST Repository

    Varga, Laszlo

    2016-10-20

    Various examples are provided for x-ray imaging of the microstructure of materials. In one example, a system for non-destructive material testing includes an x-ray source configured to generate a beam spot on a test item; a grid detector configured to receive x- rays diffracted from the test object; and a computing device configured to determine a microstructure image based at least in part upon a diffraction pattern of the x-rays diffracted from the test object. In another example, a method for determining a microstructure of a material includes illuminating a beam spot on the material with a beam of incident x-rays; detecting, with a grid detector, x-rays diffracted from the material; and determining, by a computing device, a microstructure image based at least in part upon a diffraction pattern of the x-rays diffracted from the material.

  13. Gamma Ray Shielding Study of Barium–Bismuth–Borosilicate Glasses as Transparent Shielding Materials using MCNP-4C Code, XCOM Program, and Available Experimental Data

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2017-02-01

    Full Text Available In this work, linear and mass attenuation coefficients, effective atomic number and electron density, mean free paths, and half value layer and 10th value layer values of barium–bismuth–borosilicate glasses were obtained for 662 keV, 1,173 keV, and 1,332 keV gamma ray energies using MCNP-4C code and XCOM program. Then obtained data were compared with available experimental data. The MCNP-4C code and XCOM program results were in good agreement with the experimental data. Barium–bismuth–borosilicate glasses have good gamma ray shielding properties from the shielding point of view.

  14. Experimental verification of photon: A program for use in x-ray shielding calculations

    International Nuclear Information System (INIS)

    Brauer, E.; Thomlinson, W.

    1987-01-01

    At the National Synchrotron Light Source, a computer program named PHOTON has been developed to calculate radiation dose values around a beam line. The output from the program must be an accurate guide to beam line shielding. To test the program, a series of measurements of radiation dose were carried out using existing beam lines; the results were compared to the theoretical calculations of PHOTON. Several different scattering geometries, scattering materials, and sets of walls and shielding materials were studied. Results of the measurements allowed many advances to be made in the program, ultimately resulting in good agreement between the theory and experiment. 3 refs., 6 figs

  15. Micro-fresnel structures for microscopy of laser generated bright x-ray sources

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Shavers, D.C.; Flanders, D.C.; Smith, H.I.

    1979-01-01

    A brief parametric survey of the x-ray characteristics of a gold micro-disk irradiated at 3 x 10 14 watt/cm 2 by a 1 nsec Nd-glass laser pulse has been provided as an example of a laser generated bright x-ray source. It was shown that a simple phenomenological model of the laser generated x-ray source as a microscopic equilibrium plasma radiating as a blackbody for a finite time determined by its hydrodynamic disassembly and radiation losses, serves to provide an adequate approximation to the x-ray characteristics of such sources. The current state of x-ray microscopy within the LLL laser fusion program was briefly reviewed. Kirpatrick--Baez grazing incidence reflection x-ray microscopes are being used to provide 3 to 5 μm resolution, broadband images (ΔE/E approx. 0.3) over a spectral range from .6 keV to 3.5 keV. Zone Plate Coded Imaging is used to provide 5 to 10 μm resolution, broadband (ΔE/E approx. 0.5) images over a spectral range from 3 keV to 50 keV. Efficient x-ray lensing elements with anticipated submicron resolution are being developed for narrowband (ΔE/E approx. 10 -2 ) imaging applications over a spectral range .1 keV to 8 keV. The x-ray lens design is that of a transmission blazed Fresnel phase plate. Micro--Fresnel zone plates with 3200 A minimum linewidth have been fabricated and preliminary resolution tests begun. The first resolution test pattern, having minimum linewidth of 2.5 μm, was imaged in lambda = 8.34 A light with no difficulty. Newer test patterns with submicron minimum line are being prepared for the next stage of resolution testing. An off-axis Fresnel zone plate with 1600 A minimum linewidth is presently being fabricated for use as an imaging spectrometer in order to provide spatially separated, chromatically distinct images of characteristic line emissions from laser fusion targets

  16. GRAP, Gamma-Ray Level-Scheme Assignment

    International Nuclear Information System (INIS)

    Franklyn, C.B.

    2002-01-01

    1 - Description of program or function: An interactive program for allocating gamma-rays to an energy level scheme. Procedure allows for searching for new candidate levels of the form: 1) L1 + G(A) + G(B) = L2; 2) G(A) + G(B) = G(C); 3) G(A) + G(B) = C (C is a user defined number); 4) L1 + G(A) + G(B) + G(C) = L2. Procedure indicates intensity balance of feed and decay of each energy level. Provides for optimization of a level energy (and associated error). Overall procedure allows for pre-defining of certain gamma-rays as belonging to particular regions of the level scheme, for example, high energy transition levels, or due to beta- decay. 2 - Method of solution: Search for cases in which the energy difference between two energy levels is equal to a gamma-ray energy within user-defined limits. 3 - Restrictions on the complexity of the problem: Maximum number of gamma-rays: 999; Maximum gamma ray energy: 32000 units; Minimum gamma ray energy: 10 units; Maximum gamma-ray intensity: 32000 units; Minimum gamma-ray intensity: 0.001 units; Maximum number of levels: 255; Maximum level energy: 32000 units; Minimum level energy: 10 units; Maximum error on energy, intensity: 32 units; Minimum error on energy, intensity: 0.001 units; Maximum number of combinations: 6400 (ca); Maximum number of gamma-ray types : 127

  17. 13.1 micrometers hard X-ray focusing by a new type monocapillary X-ray optic designed for common laboratory X-ray source

    Science.gov (United States)

    Sun, Xuepeng; zhang, Xiaoyun; Zhu, Yu; Wang, Yabing; Shang, Hongzhong; Zhang, Fengshou; Liu, Zhiguo; Sun, Tianxi

    2018-04-01

    A new type of monocapillary X-ray optic, called 'two bounces monocapillary X-ray optics' (TBMXO), is proposed for generating a small focal spot with high power-density gain for micro X-ray analysis, using a common laboratory X-ray source. TBMXO is consists of two parts: an ellipsoidal part and a tapered part. Before experimental testing, the TBMXO was simulated by the ray tracing method in MATLAB. The simulated results predicted that the proposed TBMXO would produce a smaller focal spot with higher power-density gain than the ellipsoidal monocapillary X-ray optic (EMXO). In the experiment, the TBMXO performance was tested by both an optical device and a Cu target X-ray tube with focal spot of 100 μm. The results indicated that the TBMXO had a slope error of 57.6 μrad and a 13.1 μm focal spot and a 1360 gain in power density were obtained.

  18. Portable computer to reduce gamma-ray spectra for plutonium isotopic ratios

    International Nuclear Information System (INIS)

    Ruhter, W.D.; Camp, D.C.

    1981-01-01

    In response to Task A.63 of the International Safeguards Project Office (ISPO), to upgrade measurement technology used by the International Atomic Energy Agency (IAEA), a portable data-reduction microprocessor was designed and programmed which allows in-field reduction of gamma-ray spectra and interfaces with the IAEA's multichannel analyzers - the 1000 or 2000-channel memory Silena BS27/N. This report describes the components used in assembling the microprocessor unit: hardware, software used to control the unit, and the mathematical formulation used to obtain isotopic ratios from the gamma-ray data. A simple overview is presented of the unit's operation and the results of tests on gamma-ray spectra that sought to verify the unit's operating characteristics and to determine the precision and effectiveness of the software developed for data reduction

  19. Abreu system - A dosimetric system to evaluate basic parameters of photofluorographic X-ray machine

    International Nuclear Information System (INIS)

    Feital, J.C.

    1987-01-01

    In Brazil, photofluorographic X-ray machines are used for cuberculosis mass screening throughout the country. The exact number of these X-ray equipment is unknown but it is estimated to be around 1000 operating units. Twelve million miniature chest radiographs are taken per year. In order to make local inspections speedier and also aiming at its postal use, a system has been developed wich evaluates the entrace exposure of the patient, the X-ray beam half-value layer ( leading to the evaluation of the tube's total filtration ) and the beam's field size. It consists of a piece of cardboard where filters, TLDs and X-ray films are inserted. So far the system has been tested in 53 X-ray machines in Rio de Janeiro. The results show that it can be used in a national survey program. (Author) [pt

  20. Overview and status of the SIMMER testing program

    International Nuclear Information System (INIS)

    Scott, J.H.

    1979-01-01

    Los Alamos Scientific Laboratory has undertaken an extensive experiment analysis program to test the results of SIMMER Liquid Metal Fast Breeder Reactor (LMFBR) accident calculations. Initially, we will test the postdisassembly work-energy partition problem. The SIMMER-calculated order-of-magnitude reduction of available kinetic energy following a severe hypothetical core-disruptive accident (HCDA) can be attributed to (1) purely fluid-dynamic effects; and (2) rate-controlled effects, such as phase transitions and heat transfer. We have chosen to test separately each class of mitigator. In this paper we review the experiments initially chosen for testing of each class of mitigator and report on the status of the analyses. We enumerate several problems in SIMMER that experiment analysis has disclosed. Finally, needs for future experiments are discussed

  1. Gamma-ray spectrum of the radiaoctive dust produced by the super-hydrogen bomb test explosion on March 1, 1954

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, S.

    1987-03-15

    The super-hydrogen bomb test explosion, the so-called Bravo test of a fission-fusion-fission bomb, was carried out on Bikini Atoll in the mid-Pacific on March 1, 1954. Twenty-three Japanese fishermen on board a fishing boat about 90 miles north-east of the test site were attacked unexpectedly by the fallout, radioactive fine debris of coral reef. Within several months after the accident by radiochemical analysis about 20 different nuclides of fission products and, in addition, a considerable amount of /sup 235/U were discovered from the fallout. As we have been preserving a minute amount of the original fallout dust collected on board the fishing boat 31 years ago, measurements of ..gamma.. rays from it have recently been used to find some active nuclides, if still existing. In the ..gamma..-ray spectrum observed there exist evident peaks of ..gamma.. and X-rays from /sup 241/Am, /sup 155/Eu, /sup 137/Cs and /sup 60/Co. Absolute intensities of these four nuclides, still remaining 31 years after the explosion of the bomb, have been estimated. Some discussion on our finding is presented.

  2. Risk-based inservice testing program modifications at Palo Verde nuclear generating station

    International Nuclear Information System (INIS)

    Knauf, S.; Lindenlaub, B.; Linthicum, R.

    1996-01-01

    Arizona Public Service Company (APS) is investigating changes to the Palo Verde Inservice Testing (IST) Program that are intended to result in the reduction of the required test frequency for various valves in the American Society of Mechanical Engineers (ASME) Section XI IST program. The analytical techniques employed to select candidate valves and to demonstrate that these frequency reductions are acceptable are risk based. The results of the Palo Verde probabilistic risk assessment (PRA), updated in June 1994, and the risk significant determination performed as part of the implementation efforts for 10 CFR 50.65 (the maintenance rule) were used to select candidate valves for extended test intervals. Additional component level evaluations were conducted by an 'expert panel.' The decision to pursue these changes was facilitated by the ASME Risk-Based Inservice Testing Research Task Force for which Palo Verde is participating as a pilot plant. The NRC's increasing acceptance of cost beneficial licensing actions and risk-based submittals also provided incentive to seek these changes. Arizona Public Service is pursuing the risk-based IST program modification in order to reduce the unnecessary regulatory burden of the IST program through qualitative and quantitative analysis consistent with maintaining a high level of plant safety. The objectives of this project at Palo Verde are as follows: (1) Apply risk-based technologies to IST components to determine their risk significance (i.e., high or low). (2) Apply a combination of deterministic and risk-based methods to determine appropriate testing requirements for IST components including improvement of testing methods and frequency intervals for high-risk significant components. (3) Apply risk-based technologies to high-risk significant components identified by the open-quotes expert panelclose quotes and outside of the IST program to determine whether additional testing requirements are appropriate

  3. Risk-based inservice testing program modifications at Palo Verde nuclear generating station

    Energy Technology Data Exchange (ETDEWEB)

    Knauf, S.; Lindenlaub, B.; Linthicum, R.

    1996-12-01

    Arizona Public Service Company (APS) is investigating changes to the Palo Verde Inservice Testing (IST) Program that are intended to result in the reduction of the required test frequency for various valves in the American Society of Mechanical Engineers (ASME) Section XI IST program. The analytical techniques employed to select candidate valves and to demonstrate that these frequency reductions are acceptable are risk based. The results of the Palo Verde probabilistic risk assessment (PRA), updated in June 1994, and the risk significant determination performed as part of the implementation efforts for 10 CFR 50.65 (the maintenance rule) were used to select candidate valves for extended test intervals. Additional component level evaluations were conducted by an `expert panel.` The decision to pursue these changes was facilitated by the ASME Risk-Based Inservice Testing Research Task Force for which Palo Verde is participating as a pilot plant. The NRC`s increasing acceptance of cost beneficial licensing actions and risk-based submittals also provided incentive to seek these changes. Arizona Public Service is pursuing the risk-based IST program modification in order to reduce the unnecessary regulatory burden of the IST program through qualitative and quantitative analysis consistent with maintaining a high level of plant safety. The objectives of this project at Palo Verde are as follows: (1) Apply risk-based technologies to IST components to determine their risk significance (i.e., high or low). (2) Apply a combination of deterministic and risk-based methods to determine appropriate testing requirements for IST components including improvement of testing methods and frequency intervals for high-risk significant components. (3) Apply risk-based technologies to high-risk significant components identified by the {open_quotes}expert panel{close_quotes} and outside of the IST program to determine whether additional testing requirements are appropriate.

  4. State-of-the-art report for the testing and formal verification methods for FBD program

    International Nuclear Information System (INIS)

    Jee, Eun Kyoung; Lee, Jang Soo; Lee, Young Jun; Yoo, Jun Beom

    2011-10-01

    The importance of PLC testing has increased in the nuclear I and C domain. While regulation authorities require both functional and structural testing for safety system software, FBD testing relies only on functional testing and there has been little research on structural testing techniques for FBD programs. We aim to analyze current techniques related to FBD testing and develop a structural testing technique appropriate to FBD programs. We developed structural test coverage criteria applicable to FBD programs, focusing on data paths from input edges to output edges of FBD programs. A data path condition (DPC), under which input data can flow into the output edge, is defined for each data path. We defined basic coverage, input condition coverage and complex condition coverage criteria based on the formal definition of DPC. We also developed a measurement procedure for FBD testing adequacy and a supporting tool prototype

  5. The integrated in situ testing program for the Waste Isolation Pilot Plant (WIPP)

    International Nuclear Information System (INIS)

    Matalucci, R.V.

    1987-03-01

    The US Department of Energy (DOE) is developing the Waste Isolation Pilot Plant (WIPP) Project in southeastern New Mexico as a research and development (R and D) facility for examining the response of bedded (layered) salt to the emplacement of radioactive wastes generated from defense programs. The WIPP Experimental Program consists of a technology development program, including laboratory testing and theoretical analysis activities, and an in situ testing program that is being done 659 m underground at the project site. This experimental program addresses three major technical areas that concern (1) thermal/structural interactions, (2) plugging and sealing, and (3) waste package performance. To ensure that the technical issues involved in these areas are investigated with appropriate emphasis and timing, an in situ testing plan was developed to integrate the many activities and tasks associated with the technical issues of waste disposal. 5 refs., 4 figs

  6. Polar gamma ray mode for testing weld quality natural gas pipeline

    International Nuclear Information System (INIS)

    Shahout, A. M.; Mahmood, A.Sh.

    2005-01-01

    The polar gamma-ray radiography method was studied extensively, gamma ray from Ir 192 source was used to detect weld defects in the main gas pipeline extending from Kh oms to Tripoli, gamma ray radiographic inspections were carried out according to the Astm(1) standards, and the radiographs were analyzed according to quality specifications API(2) standard-1104. The polar gamma ray mode has been applied to specimens of weld joints of pipes used in this pipeline in the reg [the kilometer 118(3)] and [the kilometer 123], and weld joints in the SLR 7 stz in the region [the kilometer 125]. The results obtained from gamma-rays have discussed and analyzed

  7. X-Ray Exam: Hip

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What It Is Why ... You Have Questions Print What It Is A hip X-ray is a safe and painless test ...

  8. X-Ray Exam: Ankle

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What It Is Why ... You Have Questions Print What It Is An ankle X-ray is a safe and painless test ...

  9. 76 FR 34086 - Mandatory Guidelines for Federal Workplace Drug Testing Programs; Request for Information...

    Science.gov (United States)

    2011-06-10

    ... Mandatory Guidelines for Federal Workplace Drug Testing Programs; Request for Information Regarding Specific Issues Related to the Use of the Oral Fluid Specimen for Drug Testing AGENCY: Substance Abuse and Mental... may be applied to the Mandatory Guidelines for Federal Workplace Drug Testing Programs (oral fluid...

  10. 78 FR 75961 - Energy Conservation Program: Test Procedures for Electric Motors

    Science.gov (United States)

    2013-12-13

    ... Conservation Program: Test Procedures for Electric Motors; Final Rule #0;#0;Federal Register / Vol. 78 , No... Procedures for Electric Motors AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy... procedures for electric motors to allow currently unregulated motors to be tested by clarifying the test...

  11. 77 FR 28805 - Energy Conservation Program: Test Procedures for Microwave Ovens

    Science.gov (United States)

    2012-05-16

    ... Energy Conservation Program: Test Procedures for Microwave Ovens AGENCY: Office of Energy Efficiency and... (SNOPR) to amend the test procedures for microwave ovens. That SNOPR proposed amendments to the DOE test... mode energy use of products that combine a microwave oven with other appliance functionality, as well...

  12. Definition study for variable cycle engine testbed engine and associated test program

    Science.gov (United States)

    Vdoviak, J. W.

    1978-01-01

    The product/study double bypass variable cycle engine (VCE) was updated to incorporate recent improvements. The effect of these improvements on mission range and noise levels was determined. This engine design was then compared with current existing high-technology core engines in order to define a subscale testbed configuration that simulated many of the critical technology features of the product/study VCE. Detailed preliminary program plans were then developed for the design, fabrication, and static test of the selected testbed engine configuration. These plans included estimated costs and schedules for the detail design, fabrication and test of the testbed engine and the definition of a test program, test plan, schedule, instrumentation, and test stand requirements.

  13. Feasibility evaluation of x-ray imaging for measurement of fuel rod bowing in CFTL test bundles

    International Nuclear Information System (INIS)

    Baker, S.P.

    1980-06-01

    The Core Flow Test Loop (CFTL) is a high temperature, high pressure, out-of-reactor helium-circulating system. It is designed for detailed study of the thermomechanical performance, at prototypic steady-state and transient operating conditions, of electrically heated rods that simulate segments of core assemblies in the Gas-Cooled Fast Breeder reactor demonstration plant. Results are presented of a feasibility evaluation of x-ray imaging for making measurements of the displacement (bowing) of fuel rods in CFTL test bundles containing electrically heated rods. A mock-up of a representative CFTL test section consisting of a test bundle and associated piping was fabricated to assist in this evaluation

  14. On the methods of determination of x-ray sources protection quality in x-ray diagnostic equipment

    International Nuclear Information System (INIS)

    Vladimirov, L.V.

    1973-01-01

    Existing procedures for assessing the quality of shielding of X-ray radiators are compared; these procedures are shown to have a number of shortcomings and to be very time-consuming. A procedure is offered in which shielding quality is tested in two stages: (1) X-ray tests aimed at determining the quality of protection of the X-ray tube unit; and (2) dosimeter tests proper. The results of measurements are compared with maximum permissible dosage rate

  15. Cosmic ray neutrino tests for heavier weak bosons and cosmic antimatter

    Science.gov (United States)

    Brown, R. W.; Stecker, F. W.

    1981-01-01

    A program for using high energy neutrino astronomy with large neutrino detectors to directly test for the existence of heavier weak intermediate vector bosons (ivb) and cosmic antimatter is described. Such observations can provide a direct test of baryon symmetric cosmologies. Changes in the total cross section for nu(N) yields mu(X) due to additional propagators are discussed and higher mass resonances in the annihilation channel bar-nu sub e e(-) yields X are analyzed. The annihilation channel is instrumental in the search for antimatter, partcularly if heavier IVB's exist.

  16. Integrated verification and testing system (IVTS) for HAL/S programs

    Science.gov (United States)

    Senn, E. H.; Ames, K. R.; Smith, K. A.

    1983-01-01

    The IVTS is a large software system designed to support user-controlled verification analysis and testing activities for programs written in the HAL/S language. The system is composed of a user interface and user command language, analysis tools and an organized data base of host system files. The analysis tools are of four major types: (1) static analysis, (2) symbolic execution, (3) dynamic analysis (testing), and (4) documentation enhancement. The IVTS requires a split HAL/S compiler, divided at the natural separation point between the parser/lexical analyzer phase and the target machine code generator phase. The IVTS uses the internal program form (HALMAT) between these two phases as primary input for the analysis tools. The dynamic analysis component requires some way to 'execute' the object HAL/S program. The execution medium may be an interpretive simulation or an actual host or target machine.

  17. Independent review of Oak Ridge HCTW test program and development of seismic evaluation criteria

    International Nuclear Information System (INIS)

    1995-05-01

    Many of the existing buildings at the Oak Ridge Y-12 Plant are steel frame construction with unreinforced hollow clay tile infill walls (HCTW). The HCTW infill provides some lateral seismic resistance to the design/evaluation basis earthquake; however acceptance criteria for this construction must be developed. The basis for the development of seismic criteria is the Oak Ridge HCTW testing and analysis program and the target performance goals of DOE 5480.28 and DOE-STD-1020-94. This report documents and independent review of the testing and analysis program and development of recommended acceptance criteria for Oak Ridge HCTW construction. The HCTW test program included ''macro'' wall in-plane and out-of-plane tests, full-scale wall in-plane and out-of-plane tests, in-situ out-of-plane test, shake table tests, and masonry component tests

  18. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl; Malinowski, K.; Czarski, T.; Kowalska-Strzęciwilk, E. [Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw (Poland); Wojeński, A.; Poźniak, K. T.; Kasprowicz, G.; Krawczyk, R.; Kolasiński, P.; Zabołotny, W.; Zienkiewicz, P. [Institute of Electronic Systems, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw (Poland); Vezinet, D.; Herrmann, A. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Mazon, D.; Jardin, A. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2016-11-15

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  19. Cosmic ray test results of the DO prototype scintillating fiber tracker

    International Nuclear Information System (INIS)

    Adams, D.; Bertram, I.; Adams, M.; Chung, M.; Baumbaugh, B.; Bross, A.; Casey, D.; Cretsinger, C.; Chang, S.; Cooper, C.

    1995-01-01

    The performance of a large scale scintillating fiber tracker with VLPC readout has been studied in a cosmic-ray test. Approximately 9.6 photoelectrons per single layer per trigger were detected at a VLPC bias voltage of 6.5V. The doublet efficiency was nearly 100% at a 0.1% noise level and a position resolution of about 140μm was measured. The authors also studied the relationship between VLPC performance and VLPC bias voltage by measuring single fiber efficiency as a function of VLPC bias in the range 6.2V to 7.0V at a fixed temperature of 6.5 degrees K. They observed no significant variation in VLPC performance within this bias range

  20. Cosmic ray test results of the DOe prototype scintillating fiber tracker

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D. [Rice Univ., Houston, TX (United States); Adams, M. [University of Illinois at Chicago, IL (United States); Baumbaugh, B. [Notre Dame Univ., IN (United States); Bertram, I. [Rice Univ., Houston, TX (United States); Bross, A. [Fermi National Accelerator Lab., Batavia, IL (United States); Casey, D. [Rochester Univ., NY (United States); Chang, S. [Northeastern Univ., Boston, MA (United States); Chung, M. [University of Illinois at Chicago, IL (United States); Cooper, C. [Purdue Univ., Lafayette, IN (United States); Cretsinger, C. [Rochester Univ., NY (United States); Demina, R. [Northeastern Univ., Boston, MA (United States); Fanourakis, G. [Rochester Univ., NY (United States); Gruenendahl, S. [Rochester Univ., NY (United States); Hinson, J. [Purdue Univ., Lafayette, IN (United States); Howell, B. [Purdue Univ., Lafayette, IN (United States); Johari, H. [Northeastern Univ., Boston, MA (United States); Kang, J.S. [Korea Univ., Seoul (Korea, Republic of); Kim, C.L. [Korea Univ., Seoul (Korea, Republic of); Kim, S.K. [Seoul National Univ. (Korea, Republic of); Koltick, D. [Purdue Univ., Lafayette, IN (United States); Lobkowicz, F. [Rochester Univ., NY (United States); Margulies, S. [University of Illinois at Chicago, IL (United States); Moromisato, J. [Northeastern Univ., Boston, MA (United States); Narain, M. [Fermi National Accelerator Lab., Batavia, IL (United States); Park, C.H. [Fermi National Accelerator Lab., Batavia, IL (United States); Park, Y.M. [Kyungsung Univ., Pusan (Korea, Republic of); Reucroft, S. [Northeastern Univ., Boston, MA (United States); Ruchti, R. [Notre Dame Univ., IN (United States); Solomon, J. [University of Illinois at Chicago, IL (United States); VonGoeler, E. [Northeastern Univ., Boston, MA (United States); Warchol, J. [Notre Dame Univ., IN (United States); Wayne, M. [Notre Dame Univ., IN (United States); Won, E. [Rochester Univ., NY (United States); Yu, Y. [Seoul National Univ. (Korea)

    1995-11-01

    The performance of a large scale scintillating fiber tracker with VLPC readout has been studied in a cosmic-ray test. Approximately 9.6 photoelectrons per single layer per trigger were detected at a VLPC bias voltage of 6.5V. The doublet efficiency was nearly 100% at a 0.1% noise level and a position resolution of about 140{mu}m was measured. We also studied the relationship between VLPC performance and VLPC bias voltage by measuring single fiber efficiency as a function of VLPC bias in the range 6.2V to 7.0V at a fixed temperature of 6.5K. We observed no significant variation in VLPC performance within this bias range. (orig.).

  1. PWR Blowdown Heat Transfer Separate-Effects Program. Thermal-Hydraulic Test Facility experimental data report for test 166S

    International Nuclear Information System (INIS)

    Clemons, V.D.; White, M.D.; Hedrick, R.A.

    1978-01-01

    Reduced instrument responses are presented for Thermal-Hydraulic Test Facility (THTF) test 166S, which is part of the ORNL Pressurized-Water Reactor (PWR) Blowdown Heat Transfer Separate-Effects Program. The objective of the program is to investigate the thermal-hydraulic phenomenon governing the energy transfer and transport processes that occur during a loss-of-coolant accident in a PWR system. Test 166S was conducted to obtain thermal-hydraulic and CHF information in THTF bundle 1 with an intact hot leg. The primary purpose of this report is to make the reduced instrument responses during tests 166S available. These are presented in graphical form in engineering units and have been analyzed only to the extent necessary to ensure reasonableness and consistency

  2. Summary and recommendations of the NRC/INEL Activated Carbon Testing Program

    International Nuclear Information System (INIS)

    Scarpellino, C.D.; Sill, C.W.

    1986-01-01

    The Committee on Nuclear Air and Gas Treatment (CONAGT) of the American Society of Mechanical Engineers (ASME) sponsored an interlaboratory testing program, round-robin, of nuclear-grade activated carbon. The results of this round-robin revealed gross differences in penetration of radio-labeled methyl iodide as measured by the various laboratories when using Method A of the ASTM D-3803-79 Standard. These differences prompted the Nuclear Regulatory Commission (NRC) to establish the NRC/INEL Activated Carbon Testing Program to determine the causes of these discrepancies and to provide recommendations that could lead to an accurate and reliable testing procedure that would ensure an adequate method for assessing the capability of activated carbon to remove radioiodine from gas streams within commercial nuclear power plants. The NRC/INEL Activated Carbon Testing Program has conducted formal and informal interlaboratory comparisons to identify problems with the test method and its application and to assess the effectiveness of changes to procedures and equipment voluntarily implemented by commercial laboratories to mitigate the disparity of test results. The results of the first formal NRC/INEL Interlaboratory Comparison (IC) essentially verified the CONAGT round-robin results despite the use of a detailed test protocol. This data indicated that many of the participating laboratories probably had been operating outside the ASTM specifications for relative humidity (RH) and flow. In addition, this process provided information which was used to modify the testing protocol employed for the second NRC/INEL Interlaboratory Comparison (IC-2) to make it more rugged and reliable. These changes to the protocol together with the results of INEL sensitivity testing are the basis for the recommendations presented

  3. Electron ray tracing with high accuracy

    International Nuclear Information System (INIS)

    Saito, K.; Okubo, T.; Takamoto, K.; Uno, Y.; Kondo, M.

    1986-01-01

    An electron ray tracing program is developed to investigate the overall geometrical and chromatic aberrations in electron optical systems. The program also computes aberrations due to manufacturing errors in lenses and deflectors. Computation accuracy is improved by (1) calculating electrostatic and magnetic scalar potentials using the finite element method with third-order isoparametric elements, and (2) solving the modified ray equation which the aberrations satisfy. Computation accuracy of 4 nm is achieved for calculating optical properties of the system with an electrostatic lens

  4. Testing Algorithmic Skills in Traditional and Non-Traditional Programming Environments

    Science.gov (United States)

    Csernoch, Mária; Biró, Piroska; Máth, János; Abari, Kálmán

    2015-01-01

    The Testing Algorithmic and Application Skills (TAaAS) project was launched in the 2011/2012 academic year to test first year students of Informatics, focusing on their algorithmic skills in traditional and non-traditional programming environments, and on the transference of their knowledge of Informatics from secondary to tertiary education. The…

  5. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1992-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high-power laser pulses synchronized to the electron beam, suitable for studies of new methods of high-gradient acceleration and state-of-the-art Free-Electron Lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps ND:YAG laser and a 500 mJ, 10 to 100 ps C0 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various laser acceleration schemes, Free-Electron Laser experiments and a program on the development of high-brightness electron beams. The ATF's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the high-power laser will begin operation this year

  6. The BNL Accelerator Test Facility and experimental program

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; State Univ. of New York, Stony Brook, NY

    1991-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high power laser pulses synchronized to the electron beam, suitable for studies of new methods of high gradient acceleration and state of the art free electron lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 to 100 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps Nd:YAG laser and a 100 mJ, 10 ps CO 2 laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various acceleration schemes, Free-Electron Laser experiments and a program on the development of high brightness electron beams. The AFT's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the High power laser will begin operation this year. 28 refs., 4 figs

  7. DOE standard: Filter test facility quality program plan

    International Nuclear Information System (INIS)

    1999-02-01

    This standard was developed primarily for application in US Department of Energy programs. It contains specific direction for HEPA filter testing performed at a DOE-accepted HEPA Filter Test Facility (FTF). Beneficial comments (recommendations, additions, deletions) and any pertinent data that may improve this document should be sent to the Office of Nuclear Safety Policy and Standards (EH-31), US Department of Energy, Washington, DC 20585, by letter or by using the self-addressed Document Improvement Proposal form (DOE F 1300.3) appearing at the end of this document

  8. Optimized FFTF Acceptance Test Program covering Phases III, IV, and V

    International Nuclear Information System (INIS)

    Wykoff, W.R.; Jones, D.H.

    1977-03-01

    A detailed review of Phases III, IV, and V of the FFTF Acceptance Test Program has been completed. The purpose of this review was to formulate that test sequence which not only meets requirements for safe, reliable and useful operation of the plant, but also results in the earliest prudent demonstration of full-power performance. A test sequence based on the underlying assumption that sodium flows into the secondary sodium storage tank (T-44) no later than August 31, 1978, is described in detail. A time-scale which allows extra time to put systems and equipment into operation the first time, debugging, and learning how to operate most effectively has been superimposed on the test sequence. Time is not included for major equipment malfunctions. This test plan provides the basis for coordinating the many and varied activities and interfaces necessary for successful and timely execution of the FFTF Acceptance Test Program. In this report, the need dates have been identified for presently scheduled test articles and standard core components

  9. Software Review: A program for testing capture-recapture data for closure

    Science.gov (United States)

    Stanley, Thomas R.; Richards, Jon D.

    2005-01-01

    Capture-recapture methods are widely used to estimate population parameters of free-ranging animals. Closed-population capture-recapture models, which assume there are no additions to or losses from the population over the period of study (i.e., the closure assumption), are preferred for population estimation over the open-population models, which do not assume closure, because heterogeneity in detection probabilities can be accounted for and this improves estimates. In this paper we introduce CloseTest, a new Microsoft® Windows-based program that computes the Otis et al. (1978) and Stanley and Burnham (1999) closure tests for capture-recapture data sets. Information on CloseTest features and where to obtain the program are provided.

  10. Nuclear waste transportation package testing: A review of selected programs in the United States and abroad

    International Nuclear Information System (INIS)

    Snedeker, D.F.

    1990-12-01

    This report provides an overview of some recent nuclear waste transportation package development programs. This information is intended to aid the State of Nevada in its review of US Department of Energy (DOE) nuclear waste transportation programs. This report addresses cask testing programs in the United Kingdom and selected 1/4 and full scale testing in the US. Facilities that can provide cask testing services, both in the US and to a limited extent abroad, are identified. The costs for different type test programs are identified as a means to estimate costs for future test programs. Not addressed is the public impact such testing might have in providing an increased sense of safety or confidence. The British test program was apparently quite successful in demonstrating safety to the public at the time. There is no US test effort that is similar in scope for direct comparison. Also addressed are lessons learned from testing programs and areas that may merit possible future integrated examination. Areas that may require further examination are both technical and institutional. This report provides information which, when combined with other sources of information will enable the State of Nevada to assess the following areas: feasibility of full scale testing; costs of full scale tests; potential benefits of testing; limits that full scale testing impose; and disadvantages of emphasis on testing vs analytical solutions. This assessment will then allow the state to comment on DOE Office of Civilian Radioactive Waste Management (OCRWM) plans for the development and licensing of new shipping cask designs. These plans currently expect contractors to perform engineering testing for materials development, quarter scale model testing to validate analytical assessments and full scale prototype testing of operational features. DOE currently plans no full scale or extra-regulatory destructive testing to aid in cask licensing. 1 tab

  11. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  12. Integrated X-ray testing of the electro-optical breadboard model for the XMM reflection grating spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bixler, J.V.; Craig, W.; Decker, T. [Lawrence Livermore National Lab., CA (United States); Aarts, H.; Boggende, T. den; Brinkman, A.C. [Space Research Organization Netherlands, Utrecht (Netherlands); Burkert, W.; Brauninger, H. [Max-Planck Institute fur Extraterrestische Physik, Testanlage (Germany); Branduardi-Raymont, G. [Univ. College London (United Kingdom); Dubbeldam, L. [Space Research Organization Netherlands, Leiden (Netherlands)] [and others

    1994-07-12

    X-ray calibration of the Electro-Optical Breadboard Model (EOBB) of the XXM Reflection Grating Spectrometer has been carried out at the Panter test facility in Germany. The EOBB prototype optics consisted of a four-shell grazing incidence mirror module followed by an array of eight reflection gratings. The dispersed x-rays were detected by an array of three CCDs. Line profile and efficiency measurements where made at several energies, orders, and geometric configurations for individual gratings and for the grating array as a whole. The x-ray measurements verified that the grating mounting method would meet the stringent tolerances necessary for the flight instrument. Post EOBB metrology of the individual gratings and their mountings confirmed the precision of the grating boxes fabrication. Examination of the individual grating surface`s at micron resolution revealed the cause of anomalously wide line profiles to be scattering due to the crazing of the replica`s surface.

  13. Calibration of hard x-ray (15 - 50 keV) optics at the MPE test facility PANTER

    Science.gov (United States)

    Bräuninger, Heinrich; Burkert, Wolfgang; Hartner, Gisela D.; Citterio, Oberto; Ghigo, Mauro; Mazzoleni, Francesco; Pareschi, Giovanni; Spiga, Daniele

    2004-02-01

    The Max-Planck-Institut für extraterrestrische Physik (MPE) in Garching, Germany, operates the large X-ray beam line facility PANTER for testing astronomical systems. At PANTER a number of telescopes like EXOSAT, ROSAT, SAX, JET-X, ABRIXAS, XMM and SWIFT operating in the soft energy range (0.02 - 15 keV) have been successfully calibrated. In the present paper we report on an important upgrade recently implemented that enables the calibration of hard X-ray optics (from 15 up to 50 keV). Currently hard X-ray optics based on single and multilayer coating are being developed for several future X-ray missions. The hard X-ray calibrations at PANTER are carried out by a high energy source based on an electron gun and several anodes, able to cover the energy range from 4.5 up to 50 keV. It provides fluxes up to 104 counts/sec/cm2 at the instrument chamber with a stability better than 1%. As detector a pn-CCD camera operating between 0.2 and 50 keV and a collecting area of 36 cm2 is used. Taking into account the high energy resolution of the CCD (145 eV at 6 keV), a very easy way to operate the facility in hard X-ray is in energy-dispersive mode (i.e. with a broad-band beam). A double crystal monochromator is also available providing energies up to 20 keV. In this paper we present the first results obtained by using PANTER for hard X-ray characterizations, performed on prototype multilayer optics developed by the Osservatorio Astronomico di Brera (OAB), Milano, Italy, and the Harvard-Smithsonian Center for Astrophysics (CfA), Cambridge, MA, USA.

  14. Novel Hybrid CMOS X-ray Detector Developments for Future Large Area and High Resolution X-ray Astronomy Missions

    Science.gov (United States)

    Falcone, Abe

    In the coming years, X-ray astronomy will require new soft X-ray detectors that can be read very quickly with low noise and can achieve small pixel sizes over a moderately large focal plane area. These requirements will be present for a variety of X-ray missions that will attempt to address science that was highly ranked by the 2010 Decadal Survey, including missions with science that overlaps with that of IXO and Athena, as well as other missions addressing science topics beyond those of IXO and Athena. An X-ray Surveyor mission was recently chosen by NASA for study by a Science & Technology Definition Team (STDT) so it can be considered as an option for an upcom-ing flagship mission. A mission such as this was endorsed by the NASA long term planning document entitled "Enduring Quests, Daring Visions," and a detailed description of one possible reali-zation of such a mission has been referred to as SMART-X, which was described in a recent NASA RFI response. This provides an example of a future mission concept with these requirements since it has high X-ray throughput and excellent spatial resolution. We propose to continue to modify current active pixel sensor designs, in particular the hybrid CMOS detectors that we have been working with for several years, and implement new in-pixel technologies that will allow us to achieve these ambitious and realistic requirements on a timeline that will make them available to upcoming X-ray missions. This proposal is a continuation of our program that has been work-ing on these developments for the past several years. The first 3 years of the program led to the development of a new circuit design for each pixel, which has now been shown to be suitable for a larger detector array. The proposed activity for the next four years will be to incorporate this pixel design into a new design of a full detector array (2k×2k pixels with digital output) and to fabricate this full-sized device so it can be thoroughly tested and

  15. Test results of a new detector system for gamma ray isotopic measurements

    International Nuclear Information System (INIS)

    Malcom, J.E.; Bonner, C.A.; Hurd, J.R.; Fleissner,

    1993-01-01

    A new type of gamma-ray detector system for isotopic measurements has been developed. This new system, a ''Duo detector'' array, consists of two intrinsic germanium detectors, a planar followed by a coaxial mounted on the same axis within a single cryostat assembly. This configuration allows the isotopic analysis system to take advantage of spectral data results that are collected simultaneously from different gamma-ray energy regimes. Princeton Gamma Tech (PGT) produced several prototypes of this Duo detector array which were then tested by Rocky Flats personnel until the design was optimized. An application for this detector design is in automated, roboticized NDA systems such as those being developed at the Los Alamos TA-55 Plutonium Facility. The Duo detector design reduces the space necessary for the isotopic instrument by a factor of two (only one liquid nitrogen dewar is needed), and also reduces the complexity of the mechanical systems and controlling software. Data will be presented on measurements of nuclear material with a Duo detector for a wide variety of matrices. Results indicate that the maximum count rate can be increased up to 100,000 counts per second yet maintaining excellent resolution and energy rate product

  16. Implementing a routine, voluntary HIV testing program in a Massachusetts county prison.

    Science.gov (United States)

    Liddicoat, Rebecca V; Zheng, Hui; Internicola, Jeanne; Werner, Barbara G; Kazianis, Arthur; Golan, Yoav; Rubinstein, Eric P; Freedberg, Kenneth A; Walensky, Rochelle P

    2006-11-01

    Although U.S. prison inmates have higher rates of HIV infection than the general population, most inmates are not routinely tested for HIV infection at prison entry. The study objective was to implement a routine, voluntary HIV testing program in a Massachusetts county prison. During admission, inmates were given group HIV pre-test counseling and were subsequently offered private HIV testing. This intervention was compared to a control period during which HIV testing was provided only upon inmate or physician request. Between November 2004 and April 2005, 1,004 inmates met inclusion criteria and were offered routine, voluntary HIV testing. Of these, 734 (73.1%) accepted, 2 (0.3%) were HIV-infected, and 457 (45.5%) had been tested for HIV in the previous year. The testing rate of 73.1% was significantly increased from the rate of 18.0% (318 of 1,723) during the control period (pprison setting. Careful attention should be paid to prevent redundancy of testing efforts in the prison population. Implementing a routine HIV testing program among prison inmates greatly increased testing rates compared to on-request testing.

  17. Handbook for Classroom Testing in Peace Corps Language Programs. Manual T0068.

    Science.gov (United States)

    Anderson, Neil J.

    This manual provides instructors in Peace Corps language training programs with information about two kinds of classroom testing: formative, ongoing testing and summative testing that occurs at the end of an instructional period. The first of the manual's four chapters on the purposes of language testing, discusses language testing within a…

  18. Analysis of X-Ray (L) spectra of heavy elements

    International Nuclear Information System (INIS)

    Souza Coelho, L.F. de.

    1976-08-01

    The general problem of obtaining and analysing spectra is presented, with emphasis in the comparison of methods for the analysis of gamma rays and X rays. The method proposed to obtain a standard and later the intensities of lines of an X-ray (L) spectrum is discussed. The good eesults obtained by the program RAIOXL, when simulated spectra are used, and by the program RAIXL1, when doublets are decomposed, are shown. In annex A, the listings of the programs used are presented, and in annex B a review is made of the analytical formulae used for adjustment of the pulses. (I.C.R.) [pt

  19. The generation, validation and testing of a coupled 219-group neutron 36-group gamma ray AMPX-II library

    International Nuclear Information System (INIS)

    Panini, G.C.; Siciliano, F.; Lioi, A.

    1987-01-01

    The main characteristics of a P 3 coupled 219-group neutron 36-group gamma-ray library in the AMPX-II Master Interface Format obtained processing ENDF/B-IV data by means of various AMPX-II System modules are presented in this note both for the more reprocessing aspects and features of the generated component files-neutrons, photon and secondary gamma-ray production cross sections. As far as the neutron data are concerned there is the avaibility of 186 data sets regarding most significant fission products. Results of the additional validation of the neutron data pertaining to eighteen benchmark experiments are also given. Some calculational tests on both neutron and coupled data emphasize the important role of the secondary gamma-ray data in nuclear criticality safety calculations

  20. Overview of high intensity x-ray and gamma-ray sources

    International Nuclear Information System (INIS)

    Prestwich, K.R.; Lee, J.R.; Ramirez, J.J.; Sanford, T.W.L.; Agee, F.J.; Frazier, G.B.; Miller, A.R.

    1987-01-01

    The requirements for intense x-ray and gamma-ray sources to simulate the radiation effects from nuclear weapons has led to the development of several types of terawatt-pulsed power systems. One example of a major gamma-ray source is Aurora, a 10-MV, 1.6-MA, 120-ns four-module, electron-beam generator. Recent requirements to improve the dose rate has led to the Aurora upgrade program and to the development of the 20-MV, 800-kA, 40-ns Hermes-III electron-beam accelerator. The Aurora program includes improvements to the pulsed power system and research on techniques to improve the pulse shape of the electron beam. Hermes III will feature twenty 1-MV, 800-kA induction accelerator cavities supplying energy to a magnetically insulated transmission line adder. Hermes III will become operational in 1988. Intense x-ray sources consist of pulsed power systems that operate with 1-MV to 2-MV output voltages and up to 25-TW output powers. These high powers are achieved with either low impedance electron-beam generators or multimodular pulsed power systems. The low-impedance generators have high voltage Marx generators that store the energy and then sequentially transfer this energy to pulse-forming transmission lines with lower and lower impedance until the high currents are reached. In the multimode machines, each module produces 0.7-TW to 4-TW output pulses, and all of the modules are connected together to supply energy to a single diode