WorldWideScience

Sample records for ray intensity increases

  1. Sudden Intensity Increases and Radial Gradient Changes of Cosmic Ray Mev Electrons and Protons Observed at Voyager 1 Beyond 111 AU in the Heliosheath

    Science.gov (United States)

    Webber, W. R.; Mcdonald, F. B.; Cummings, A. C.; Stone, E. C.; Heikkila, B.; Lal, N.

    2012-01-01

    Voyager 1 has entered regions of different propagation conditions for energetic cosmic rays in the outer heliosheathat a distance of about 111 AU from the Sun. The low energy 614 MeV galactic electron intensity increased by 20over a time period 10 days and the electron radial intensity gradient abruptly decreased from 19AU to 8AU at2009.7 at a radial distance of 111.2 AU. At about 2011.2 at a distance of 116.6 AU a second abrupt intensity increase of25 was observed for electrons. After the second sudden electron increase the radial intensity gradient increased to18AU. This large positive gradient and the 13 day periodic variations of 200 MeV particles observed near theend of 2011 indicate that V1 is still within the overall heliospheric modulating region. The implications of these resultsregarding the proximity of the heliopause are discussed.

  2. Sulphur mountain: Cosmic ray intensity records

    International Nuclear Information System (INIS)

    Venkatesan, D.; Mathews, T.

    1985-01-01

    This book deals with the comic ray intensity registrations at the Sulphur Mountain Cosmic Ray Laboratory. The time series of intensity form a valuable data-set, for studying cosmic ray intensity variations and their dependence on solar activity. The IGY neutron monitor started operating from July 1, 1957 and continued through 1963. Daily mean values are tabulated for the period and these are also represented in plots. This monitor was set up by the National Research Council of Canada

  3. Solar flares and the cosmic ray intensity

    International Nuclear Information System (INIS)

    Hatton, C.J.

    1980-01-01

    The relationship between the cosmic ray intensity and solar activity during solar cycle 20 is discussed. A model is developed whereby it is possible to simulate the observed cosmic ray intensity from the observed number of solar flares of importance >= 1. This model leads to a radius for the modulation region of 60-70 AU. It is suggested that high speed solar streams also made a small contribution to the modulation of cosmic rays during solar cycle 20. (orig.)

  4. Evaluation of gamma-ray intensities

    International Nuclear Information System (INIS)

    Yoshizawa, Yasukazu; Inoue, Hikaru; Hoshi, Masaharu; Shizuma, Kiyoshi; Iwata, Yosei.

    1980-04-01

    Relative intensities and intensities per decay of gamma rays were evaluated for 16 nuclides, 22 Na, 24 Na, 46 Sc, 54 Mn, 60 Co, 85 Sr, 88 Y, 95 Nb, sup(108m)Ag, 134 Cs, 133 Ba, 139 Ce, sup(180m)Hf, 198 Au, 203 Hg and 207 Bi. For most of these nuclides disintegration rates can be determined by means of β-γ or X-γ coincidence method. Since decay schemes of these nuclides are established, intensities per decay of strong gamma rays were accurately evaluated by using weak beta-ray branching ratios, relative gamma-ray intensities and internal conversion coefficients. Half-lives of the nuclides were also evaluated. Use of the nuclides, therefore, are recommended for precision intensity calibration of the detectors. (author)

  5. Evaluation of gamma-ray intensities

    International Nuclear Information System (INIS)

    Yoshizawa, Yasukazu; Inoue, Hikaru; Hoshi, Masaharu; Shizuma, Kiyoshi; Iwata, Yosei.

    1978-03-01

    Results of literature survey and evaluation of relative intensities and intensities per decay of gamma rays are presented. Evaluations were made for 22 Na, 24 Na, 46 Sc, 48 Sc, 48 V, 54 Mn, 57 Co, 60 Co, 85 Sr, 88 Y, 95 Nb, 95 Zr, sup(108m)Ag, 134 Cs, 137 Cs, 144 Ce, 144 Pr, 203 Hg, and 207 Bi. For eight of the nuclides, the half-lives were also evaluated. (auth.)

  6. Origin of transient cosmic ray intensity variations

    International Nuclear Information System (INIS)

    Duggal, S.P.; Pomerantz, M.A.

    1977-01-01

    A new approach to determining the solar progenitor of transient cosmic ray intensity variations has revealed that in a statistical sense, solar flares, heretofore regarded as the predominant source of the modulation, actually do not precede the reduction in flux observed at earth. Superposed epoch analysis of the cosmic ray data with respect to the time of occurrence of all 379 solar flares of importance (Imp) < or =2 observed during solar cycle 20 (1964-1974 inclusive) shows that the onset of a decrease in the composite nucleonic intensity at polar stations occurs prior to the zero day (i.e., time of the flare) well before the arrival in the vicinity of earth of the associated solar plasma. The statistical significance of this result is confirmed by comparing the pooled variance determined from Chree analysis of an equal number of random epochs with that of the curve representing the flare epochs. Subdivision of the latter into three groups according to the heliographic longitude of the flares shows that whereas eastern flares might be associated with cosmic ray decreases, central (30degree to -30degree) and western flares cannot be thus related. A similar analysis of all flares of Imp< or =2 that occurred in a selected set of 24 extraordinary flare-rich active centers during 1964--1974 confirms these results and shows that the observed cosmic ray intensity decrease is, in fact, associated with the central meridian passage ( +- 1 day) of the active regions. Thus earlier conclusions concerning relationships between the heliolongitude of flares and their apparent effectiveness in producing Forbush decreases require reevaluation. The specific feature associated with solar active centers that is actually the principal source of transient modulations remanins to be identified

  7. Compton spectra of atoms at high x-ray intensity

    Science.gov (United States)

    Son, Sang-Kil; Geffert, Otfried; Santra, Robin

    2017-03-01

    Compton scattering is the nonresonant inelastic scattering of an x-ray photon by an electron and has been used to probe the electron momentum distribution in gas-phase and condensed-matter samples. In the low x-ray intensity regime, Compton scattering from atoms dominantly comes from bound electrons in neutral atoms, neglecting contributions from bound electrons in ions and free (ionized) electrons. In contrast, in the high x-ray intensity regime, the sample experiences severe ionization via x-ray multiphoton multiple ionization dynamics. Thus, it becomes necessary to take into account all the contributions to the Compton scattering signal when atoms are exposed to high-intensity x-ray pulses provided by x-ray free-electron lasers (XFELs). In this paper, we investigate the Compton spectra of atoms at high x-ray intensity, using an extension of the integrated x-ray atomic physics toolkit, xatom. As the x-ray fluence increases, there is a significant contribution from ionized electrons to the Compton spectra, which gives rise to strong deviations from the Compton spectra of neutral atoms. The present study provides not only understanding of the fundamental XFEL-matter interaction but also crucial information for single-particle imaging experiments, where Compton scattering is no longer negligible. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Sang-Kil Son was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  8. Cosmic ray intensity in the past

    International Nuclear Information System (INIS)

    Dergachev, V.A.

    1977-01-01

    Variations of cosmic rays have been investigated according to the data on the content of radiocarbon in the Earth atmosphere, on the solar activity and on the geomagnetic field. The results of spectral analysis of the data on radiocarbon (1688-1951 time interval) and the data on the numbers of sunspots have been compared. As a result of spectral analysis it has been established that the two main peaks coincide in periods (approximately 11 and approximately 80 years) and differ in amplitudes. The 11-year periods are the main periods for the solar activity, and the 80-year periods for the radiocarbon concentration. To elucidate the role of the geomagnetic field in the cosmic ray variations considered are extermal changes in the magnetic field and variations in the radiocarbon content for four time intervals: 0-500 years, 750-2200 years, 2200-4500 years and 4500-6800 years form the present. The following cycles have been revealed in the time spectra of radiocarbon; approximately 600, approximately 360, approximately 80, approximately 36 years, their relative amplitude decreasing with the period. The absence of short-range solar syscle is typical for the geomagnetic field intensity

  9. Beam intensity increases at the intense pulsed neutron source accelerator

    International Nuclear Information System (INIS)

    Potts, C.; Brumwell, F.; Norem, J.; Rauchas, A.; Stipp, V.; Volk, G.

    1985-01-01

    The Intense Pulsed Neutron Source (IPNS) accelerator system has managed a 40% increase in time average beam current over the last two years. Currents of up to 15.6μA (3.25 x 10 12 protons at 30 Hz) have been successfully accelerated and cleanly extracted. Our high current operation demands low loss beam handling to permit hands-on maintenance. Synchrotron beam handling efficiencies of 90% are routine. A new H - ion source which was installed in March of 1983 offered the opportunity to get above 8 μA but an instability caused unacceptable losses when attempting to operate at 10 μA and above. Simple techniques to control the instabilities were introduced and have worked well. These techniques are discussed below. Other improvements in the regulation of various power supplies have provided greatly improved low energy orbit stability and contributed substantially to the increased beam current

  10. Transient phenomena in cosmic ray intensity during extreme events

    Science.gov (United States)

    Agarwal, Rekha; Mishra, Rajesh K.

    2008-04-01

    In the present work an analysis has been made of the extreme events occurring during July 2005. Specifically, a rather intense Forbush decrease was observed at different neutron monitors all over the world during 16 July 2005. An effort has been made to study the effect of this unusual event on cosmic ray intensity as well as various solar and interplanetary plasma parameters. It is noteworthy that during 11 to 18 July 2005 the solar activity ranged from low to very active. Especially low levels occurred on 11, 15, and 17 July whereas high levels took place on 14 and 16 July 2005. The Sun is observed to be active during 11 to 18 July 2005, the interplanetary magnetic field intensity lies within 15 nT, and solar wind velocity was limited to ˜500 kms-1. The geomagnetic activity during this period remains very quiet, the Kp index did not exceed 5, the disturbance storm time Dst index remains ˜-70 nT and no sudden storm commencement has been detected during this period. It is noted that for the majority of the hours, the north/south component of the interplanetary magnetic field, Bz, remains negative, and the cosmic ray intensity increases and shows good/high correlation with Bz, as the polarity of Bz tends to shift from negative to positive values, the intensity decreases and shows good/high anti-correlation with Bz. The cosmic ray intensity tends to decrease with increase of interplanetary magnetic field strength (B) and shows anti-correlation for the majority of the days.

  11. Ultrafast absorption of intense x rays by nitrogen molecules

    Energy Technology Data Exchange (ETDEWEB)

    Buth, Christian [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); PULSE Institute for Ultrafast Energy Science, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Department of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana 70803 (United States); Argonne National Laboratory, Argonne, Illinois 60439 (United States); Liu Jicai [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Department of Mathematics and Physics, North China Electric Power University, 102206 Beijing (China); Chen, Mau Hsiung [Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Cryan, James P. [PULSE Institute for Ultrafast Energy Science, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Department of Physics, Stanford University, Stanford, California 94305 (United States); Fang Li; Hoener, Matthias; Berrah, Nora [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008 (United States); Glownia, James M. [PULSE Institute for Ultrafast Energy Science, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Department of Applied Physics, Stanford University, Stanford, California 94305 (United States); Coffee, Ryan N. [PULSE Institute for Ultrafast Energy Science, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States)

    2012-06-07

    We devise a theoretical description for the response of nitrogen molecules (N{sub 2}) to ultrashort and intense x rays from the free electron laser Linac Coherent Light Source (LCLS). We set out from a rate-equation description for the x-ray absorption by a nitrogen atom. The equations are formulated using all one-x-ray-photon absorption cross sections and the Auger and radiative decay widths of multiply-ionized nitrogen atoms. Cross sections are obtained with a one-electron theory and decay widths are determined from ab initio computations using the Dirac-Hartree-Slater (DHS) method. We also calculate all binding and transition energies of nitrogen atoms in all charge states with the DHS method as the difference of two self-consistent field (SCF) calculations ({Delta}SCF method). To describe the interaction with N{sub 2}, a detailed investigation of intense x-ray-induced ionization and molecular fragmentation are carried out. As a figure of merit, we calculate ion yields and the average charge state measured in recent experiments at the LCLS. We use a series of phenomenological models of increasing sophistication to unravel the mechanisms of the interaction of x rays with N{sub 2}: a single atom, a symmetric-sharing model, and a fragmentation-matrix model are developed. The role of the formation and decay of single and double core holes, the metastable states of N{sub 2}{sup 2+}, and molecular fragmentation are explained.

  12. Increased intensity performance of the Brookhaven AGS

    International Nuclear Information System (INIS)

    Raka, E.; Ahrens, L.; Frey, W.; Gill, E.; Glenn, J.W.; Sanders, R.; Weng, W.

    1985-05-01

    With the advent of H - injection into the Brookhaven AGS, circulating beams of up to 3 x 10 13 protons at 200 MeV have been obtained. Rf capture of 2.2 x 10 13 and acceleration of 1.73 x 10 13 up to the transition energy (approx. = 8 GeV) and 1.64 x 10 13 to full energy (approx. = 29 GeV) has been achieved. This represents a 50% increase over the best performance obtained with H + injection. The increase in circulation beam current is obtained without filling the horizontal aperture. This allows the rf capture process to utilize a larger longitudinal phase space area (approx. = 1 eV sec/bunch vs less than or equal to 0.6 eV sec with H + operation). The resulting reduction in relative longitudinal density partially offsets the increase in space charge effects at higher currents. In order to make the capture process independent of injected beam current, a dynamic beam loading compensation loop was installed on the AGS rf system. This is the only addition to the synchrotron itself that was required to reach the new intensity records. A discussion of injection, the rf capture process, and space charge effects is presented. 9 refs., 5 figs

  13. Intensity-dependent resonant transmission of x-rays in solid-density aluminum plasma

    Science.gov (United States)

    Cho, M. S.; Chung, H.-K.; Cho, B. I.

    2018-05-01

    X-ray free-electron lasers (XFELs) provide unique opportunities to generate and investigate dense plasmas. The absorption and transmission properties of x-ray photons in dense plasmas are important in characterizing the state of the plasmas. Experimental evidence shows that the transmission of x-ray photons through dense plasmas depends greatly on the incident XFEL intensity. Here, we present a detailed analysis of intensity-dependent x-ray transmission in solid-density aluminum using collisional-radiative population kinetics calculations. Reverse saturable absorption (RSA), i.e., an increase in x-ray absorption with intensity has been observed for photon energies below the K-absorption edge and in the intensity range of 1016-1017 W/cm2 for XFEL photons with 1487 eV. At higher intensities, a transition from RSA to saturable absorption (SA) is predicted; thus, the x-ray absorption decreases with intensity above a threshold value. For XFEL photon energies of 1501 eV and 1515 eV, the transition from RSA to SA occurs at XFEL intensities between 1017-1018 W/cm2. Electron temperatures are predicted to be in the range of 30-50 eV for the given experimental conditions. Detailed population kinetics of the charge states explains the intensity-dependent absorption of x-ray photons and the fast modulation of XFEL pulses for both RSA and SA.

  14. Correlation between ionospheric potential and the intensity of cosmic rays

    International Nuclear Information System (INIS)

    Meyerott, R.E.; Reagan, J.B.; Evans, J.E.

    1983-01-01

    Ionospheric potential variations with a period of about 10 yr have been observed in the data that have been acquired to date. Previous studies have shown that these variations appear to be correlated inversely with sunspot number and with solar wind velocity, and directly with cosmic ray intensity. Since the cosmic ray intensity is inversely correlated with sunspot number and solar wind velocity, these correlations all suggest that the long period variations are of solar origin. In this report it is shown that, over the limited period for which ionospheric potential measurements exist, the long period variations are better correlated with the aerosol burden injected into the stratosphere by large volcanic eruptions than with the intensity of cosmic rays. This result indicates that the long period variations in ionospheric potential are of terrestrial rather than solar origin. 20 references

  15. High-intensity, subkilovolt x-ray calibration facility

    International Nuclear Information System (INIS)

    Kuckuck, R.W.; Gaines, J.L.; Ernst, R.D.

    1976-01-01

    A high-intensity subkilovolt x-ray calibration source utilizing proton-induced inner-shell atomic fluorescence of low-Z elements is described. The high photon yields and low bremsstrahlung background associated with this phenomenon are ideally suited to provide intense, nearly monoenergetic x-ray beams. The proton accelerator is a 3 mA, 300 kV Cockroft-Walton using a conventional rf hydrogen ion source. Seven remotely-selectable targets capable of heat dissipation of 5 kW/cm 2 are used to provide characteristic x-rays with energies between 100 and 1000 eV. Source strengths are of the order of 10 13 to 10 14 photons/sec. Methods of reducing spectral contamination due to hydrocarbon build-up on the target are discussed. Typical x-ray spectra (Cu-L, C-K and B-K) are shown

  16. Intensity of diffracted X-rays from biomolecules with radiation damage caused by strong X-ray pulses

    International Nuclear Information System (INIS)

    Kai, Takeshi; Tokuhisa, Atsushi; Moribayashi, Kengo; Fukuda, Yuji; Kono, Hidetoshi; Go, Nobuhiro

    2014-01-01

    In order to realize the coherent X-ray diffractive imaging of single biomolecules, the diffraction intensities, per effective pixel of a single biomolecule with radiation damage, caused by irradiation using a strong coherent X-ray pulse, were examined. A parameter survey was carried out for various experimental conditions, using a developed simulation program that considers the effect of electric field ionization, which was slightly reported on in previous studies. The two simple relationships among the parameters were identified as follows: (1) the diffraction intensity of a biomolecule slightly increases with the incident X-ray energy; and that (2) the diffraction intensity is approximately proportional to the target radius, when the radius is longer than 400 Å, since the upper limit of the incident intensity for damage to the biomolecules marginally changes with respect to the target radius. (author)

  17. Gamma-ray line intensities for depleted uranium

    International Nuclear Information System (INIS)

    Moss, C.E.

    1985-01-01

    Measurements of the gamma-ray line intensities from depleted uranium allowed us to determine which of two conflicting previous experiments was correct. For the 1001-keV line we obtain a branching ratio of 0.834 +- 0.007, in good agreement with one of the previous experiments. A table compares our intensities for several lines with those obtained in previous experiments. 5 refs., 2 figs., 1 tab

  18. Irradiation of intense characteristic x-rays from weakly ionized linear molybdenum plasma

    International Nuclear Information System (INIS)

    Sato, Eiichi; Hayasi, Yasuomi

    2003-01-01

    In the plasma flash x-ray generator, a high-voltage main condenser of approximately 200 nF is charged up to 55 kV by a power supply, and electric charges in the condenser are discharged to an x-ray tube after triggering the cathode electrode. The flash x-rays are then produced. The x-ray tube is a demountable triode that is connected to a turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to a rod molybdenum target of 2.0 mm in diameter by the electric field in the x-ray tube, weakly ionized linear plasma, which consists of molybdenum ions and electrons, forms by target evaporation. At a charging voltage of 55 kV, the maximum tube voltage was almost equal to the charging voltage of the main condenser, and the peak current was about 20 kA. When the charging voltage was increased, the linear plasma formed, and the K-series characteristic x-ray intensities increased. The K lines were quite sharp and intense, and hardly any bremsstrahlung rays were detected. The x-ray pulse widths were approximately 700 ns, and the time-integrated x-ray intensity had a value of approximately 35 μC/kg at 1.0 m from the x-ray source with a charging voltage of 50 kV. (author)

  19. Muonic X-ray intensities in phosphorus- and selenium modifications

    International Nuclear Information System (INIS)

    Kaeser, K.; Robert-Tissot, B.; Schaller, L.A.; Schellenberg, L.; Schneuwly, H.

    1979-01-01

    Muonic X-ray intensity measurements have been performed at SIN on allotropic modifications of phosphorus (white, red and black) and of selenium (red and black). Structure effects have been found in the intensity ratios of the K-series between amorphous and crystalline modifications of the same element. The effect in the higher series (Se) is less pronounced. On the other hand, the two crystalline phosphorus modifications (red and black) show the same intensity behavior. The root-mean-square radii 2 >sup(1/2) of phosphorus and (natural) selenium were found to be 3.187(3) fm and 4.138(1) fm respectively. (Auth.)

  20. Multi-keV X-ray area source intensity at SGII laser facility

    Science.gov (United States)

    Wang, Rui-rong; An, Hong-hai; Xie, Zhi-yong; Wang, Wei

    2018-05-01

    Experiments for investigating the feasibility of multi-keV backlighters for several different metallic foil targets were performed at the Shenguang II (SGII) laser facility in China. Emission spectra in the energy range of 1.65-7.0 keV were measured with an elliptically bent crystal spectrometer, and the X-ray source size was measured with a pinhole camera. The X-ray intensity near 4.75 keV and the X-ray source size for titanium targets at different laser intensity irradiances were studied. By adjusting the total laser energy at a fixed focal spot size, laser intensity in the range of 1.5-5.0 × 1015 W/cm2, was achieved. The results show that the line emission intensity near 4.75 keV and the X-ray source size are dependent on the laser intensity and increase as the laser intensity increases. However, an observed "peak" in the X-ray intensity near 4.75 keV occurs at an irradiance of 4.0 × 1015 W/cm2. For the employed experimental conditions, it was confirmed that the laser intensity could play a significant role in the development of an efficient multi-keV X-ray source. The experimental results for titanium indicate that the production of a large (˜350 μm in diameter) intense backlighter source of multi-keV X-rays is feasible at the SGII facility.

  1. Intensities and strong interaction attenuation of kaonic x-rays

    CERN Document Server

    Backenstoss, Gerhard; Koch, H; Povel, H P; Schwitter, A; Tauscher, Ludwig

    1974-01-01

    Relative intensities of numerous kaonic X-ray transitions have been measured for the elements C, P, S, and Cl, from which level widths due to the strong K-nucleus absorption have been determined. From these and earlier published data, optical potential parameters have been derived and possible consequences on the nuclear matter distribution are discussed. (10 refs).

  2. X-ray absorption intensity at high-energy region

    International Nuclear Information System (INIS)

    Fujikawa, Takashi; Kaneko, Katsumi

    2012-01-01

    We theoretically discuss X-ray absorption intensity in high-energy region far from the deepest core threshold to explain the morphology-dependent mass attenuation coefficient of some carbon systems, carbon nanotubes (CNTs), highly oriented pyrolytic graphite (HOPG) and fullerenes (C 60 ). The present theoretical approach is based on the many-body X-ray absorption theory including the intrinsic losses (shake-up losses). In the high-energy region the absorption coefficient has correction term dependent on the solid state effects given in terms of the polarization part of the screened Coulomb interaction W p . We also discuss the tail of the valence band X-ray absorption intensity. In the carbon systems C 2s contribution has some influence on the attenuation coefficient even in the high energy region at 20 keV.

  3. Abnormal increase of cosmic ray on August 7th, 1972

    International Nuclear Information System (INIS)

    Kodama, Masahiro; Murakami, Kazuaki; Wada, Masami

    1974-01-01

    The abnormal increase of cosmic ray on Aug. 7th particularly the dependence of its starting time on local time was studied. Cosmic ray increased twice before and after the greatest Forbush decrease in history on August 4th and 7th, 1972. This study is a trial to estimate the anisotropic flow of solar cosmic ray from the time difference time at different places. Further, the past instance of 23 ground-level events were statistically restudied, and the relationship between the time of generation of solar cosmic ray and the time of transmission to the earth was investigated. A list is given regarding the solar cosmic ray of more than 10 9 eV which occurred since the observation had started. The list shows definite three groups. Attention is paid to the transmission time of F type which is considered to have the most simplest transmission mechanism. The dispersion of the transmission time is large regarding flare-starting time and peak wave intensity time, but is small regarding solar wave-starting time, but the dependence on the longitude is systematic. After all, cosmic ray is accelerated after 10 minutes since solar electric wave has started, and arrives at the earth most early in the case of a flare occurred at the root of garden force line toward the earth. In conclusion, the method of studying the difference of the starting time of abnormal increase according to local time may be an effective means for examining in the characteristics of anisotropic flow of solar cosmic ray. (Iwakiri, K.)

  4. Long-term variations of cosmic ray intensity

    International Nuclear Information System (INIS)

    Dergachev, V.A.; Kocharov, G.E.; Ostryakov, V.M.

    1982-01-01

    At the present time we know only one possibility to reconstruct the Cosmic Ray intensity in the past. This possibility is connected with the measurements of radiocarbon abundance in the dendrochronologically dated wood samples. As the experiments carried out with the help of spacecrafts, balloons and ground apparatus show the Galactic Cosmic Ray flux essentially varies on a short time scales. The variations are caused by different astrophysical and geophysical phenomena. 14 C isotope allows us to investigate these reasons on a more long time interval in comparison with direct observational possibilities

  5. High intensity line source for x-ray spectrometer calibration

    International Nuclear Information System (INIS)

    Thoe, R.S.

    1986-06-01

    A high intensity electron-impact x-ray source using a one-dimensional Pierce lens has been built for the purpose of calibrating a bent crystal x-ray spectrometer. This source focuses up to 100 mA of 20-keV electrons to a line on a liquid-cooled anode. The line (which can serve as a virtual slit for the spectrometer) measures approximately 800 μ x 2 cm. The source is portable and therefore adaptable to numerous types of spectrometer applications. One particular application, the calibration of a high resolution (r = 10 4 ) time-resolved cyrstal spectrometer, will be discussed in detail

  6. X-ray investigations in intensive care units

    Energy Technology Data Exchange (ETDEWEB)

    Pokieser, H.

    1981-10-01

    From special care following surgery and from arteficial respiration of polio patients the modern and very special intensive medical care has developed. At the same time the provisional bedside radiology was improved to one branch of clinical radiology with special organisation and methods of investigation. Importance and urgency of radiological information are requiring close cooperation of all medical branches. Functions of these different groups have to be defined. The movable X-ray apparatus of 20 kV output is necessary for every intensive care unit. Hard beam technique for lung X-rays, scattered radiation grids and adequate positioning of the patient are important to get the same high quality pictures than from the radiological department.

  7. X-ray investigations in intensive care units

    International Nuclear Information System (INIS)

    Pokieser, H.

    1981-01-01

    From special care following surgery and from arteficial respiration of polio patients the modern and very special intensive medical care has developed. At the same time the provisional bedside radiology was improved to one branch of clinical radiology with special organisation and methods of investigation. Importance and urgency of radiological information are requiring close cooperation of all medical branches. Functions of these different groups have to be defined. The movable X-ray apparatus of 20 kV output is necessary for every intensive care unit. Hard beam technique for lung X-rays, scattered radiation grids and adequate positioning of the patient are important to get the same high quality pictures than from the radiological department. (orig.) [de

  8. Uniformity transition for ray intensities in random media

    Science.gov (United States)

    Pradas, Marc; Pumir, Alain; Wilkinson, Michael

    2018-04-01

    This paper analyses a model for the intensity of distribution for rays propagating without absorption in a random medium. The random medium is modelled as a dynamical map. After N iterations, the intensity is modelled as a sum S of {{\\mathcal N}} contributions from different trajectories, each of which is a product of N independent identically distributed random variables x k , representing successive focussing or de-focussing events. The number of ray trajectories reaching a given point is assumed to proliferate exponentially: {{\\mathcal N}}=ΛN , for some Λ>1 . We investigate the probability distribution of S. We find a phase transition as parameters of the model are varied. There is a phase where the fluctuations of S are suppressed as N\\to ∞ , and a phase where the S has large fluctuations, for which we provide a large deviation analysis.

  9. Three dimensional analysis of cosmic ray intensity variation

    International Nuclear Information System (INIS)

    Yasue, Shin-ichi; Mori, Satoru; Nagashima, Kazuo.

    1974-01-01

    Three dimensional analysis of cosmic ray anisotropy and its time variation was performed. This paper describes the analysis of the Forbush decrease in Jan. 1968 to investigate by comparing the direction of the magnetic field in interplanetary space and the direction of the reference axis for cosmic ray anisotropy. New anisotropy becomes dominant at the time of Forbush decrease because the anisotropy of cosmic ray in calm state is wiped out. Such anisotropy produces intensity variation in neutron monitors on the ground. The characteristic parameters of three dimensional anisotropy can be determined from theoretical value and observed intensity. Analyzed data were taken for 6 days from Jan. 25 to Jan. 30, 1968, at Deep River. The decrease of intensity at Deep River was seen for several hours from 11 o'clock (UT), Jan. 26, just before The Forbush decrease. This may be due to the loss cone. The Forbush decrease began at 19 o'clock, Jan. 26, and the main phase continued to 5 o'clock in the next morning. The spectrum of variation was Psup(-0.5). The time variations of the magnetic field in interplanetary space and the reference axis of cosmic ray anisotropy are shown for 15 hours. The average directions of both are almost in coincidence. The spatial distribution of cosmic ray near the earth may be expressed by the superposition of axial symmetrical distribution along a reference axis and its push-out to the direction of 12 o'clock. It is considered that the direction of magnetic force line and the velocity of solar wind correspond to the direction of the reference axis and the magnitude of anisotropy in the direction of 12 o'clock, respectively. (Kato, T.)

  10. Research on temperature measurement by X-ray transmission intensity

    International Nuclear Information System (INIS)

    Chen, Shuyue; Cheng, Rong

    2013-01-01

    The relationship between temperature and X-ray transmission intensity was researched and analyzed by inspecting material density change, which is caused by thermal expansion. A digital radiographic system was employed to obtain the images. On this basis, we deduced the temperature formula based on the average gray level of the captured images. The measured temperatures were obtained from the experiments and the errors were analyzed. We concluded that when X-rays pass through an object, the X-ray strength and the gray level of the image under high temperatures are greater than those under lower temperatures and the image gray level error has great impact on the accuracy of the measured temperature. The presented approach allowed the non-contact temperature measurement of material

  11. RECORD-SETTING COSMIC-RAY INTENSITIES IN 2009 AND 2010

    International Nuclear Information System (INIS)

    Mewaldt, R. A.; Davis, A. J.; Leske, R. A.; Stone, E. C.; Cummings, A. C.; Labrador, A. W.; Lave, K. A.; Binns, W. R.; Israel, M. H.; Wiedenbeck, M. E.; Christian, E. R.; De Nolfo, G. A.; Von Rosenvinge, T. T.

    2010-01-01

    We report measurements of record-setting intensities of cosmic-ray nuclei from C to Fe, made with the Cosmic Ray Isotope Spectrometer carried on the Advanced Composition Explorer in orbit about the inner Sun-Earth Lagrangian point. In the energy interval from ∼70 to ∼450 MeV nucleon -1 , near the peak in the near-Earth cosmic-ray spectrum, the measured intensities of major species from C to Fe were each 20%-26% greater in late 2009 than in the 1997-1998 minimum and previous solar minima of the space age (1957-1997). The elevated intensities reported here and also at neutron monitor energies were undoubtedly due to several unusual aspects of the solar cycle 23/24 minimum, including record-low interplanetary magnetic field (IMF) intensities, an extended period of reduced IMF turbulence, reduced solar-wind dynamic pressure, and extremely low solar activity during an extended solar minimum. The estimated parallel diffusion coefficient for cosmic-ray transport based on measured solar-wind properties was 44% greater in 2009 than in the 1997-1998 solar-minimum period. In addition, the weaker IMF should result in higher cosmic-ray drift velocities. Cosmic-ray intensity variations at 1 AU are found to lag IMF variations by 2-3 solar rotations, indicating that significant solar modulation occurs inside ∼20 AU, consistent with earlier galactic cosmic-ray radial-gradient measurements. In 2010, the intensities suddenly decreased to 1997 levels following increases in solar activity and in the inclination of the heliospheric current sheet. We describe the conditions that gave cosmic rays greater access to the inner solar system and discuss some of their implications.

  12. Increasing intensity of TENS prevents analgesic tolerance in rats

    Science.gov (United States)

    Sato, Karina L.; Sanada, Luciana S.; Rakel, Barbara A.; Sluka, Kathleen A.

    2012-01-01

    Transcutaneous electrical nerve stimulation (TENS) reduces hyperalgesia and pain. Both low frequency (LF) and high frequency (HF) TENS, delivered at the same intensity (90% motor threshold (MT)) daily, result in analgesic tolerance with repeated use by the 5th day of treatment. Thecurrentstudytestedif 1) increasingintensityby 10% per daypreventsthedevelopmentoftolerance to repeated TENS, and 2) iflowerintensity TENS (50 % MT) produces an equivalentreduction in hyperalgesia when compared to 90% MT TENS. Sprague-Dawley rats with unilateral knee joint inflammation (3% carrageenan) were separated according to the intensity of TENS used: Sham, 50% LF, 50% HF, 90% LF, 90% HF, and increased intensity by 10% per day (LF and HF). The reduced mechanical withdrawal threshold following the induction of inflammation was reversed by application of TENS applied at 90% MT and increasing intensity for the first 4 days. On the 5th day, the groups that received 90% MT intensity showed tolerance. Nevertheless, the group that received an increased intensity on each day still showed a reversal of the mechanical withdrawal threshold with TENS. These results show that the development of tolerance can be delayed by increasing intensity of TENS. PMID:22858165

  13. Towards phasing using high X-ray intensity

    Directory of Open Access Journals (Sweden)

    Lorenzo Galli

    2015-11-01

    Full Text Available X-ray free-electron lasers (XFELs show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential `bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. A pattern sorting scheme is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed.

  14. Variations of interplanetary parameters and cosmic-ray intensities

    International Nuclear Information System (INIS)

    Geranios, A.

    1980-01-01

    Observations of cosmic ray intensity depressions by earth bound neutron monitors and measurements of interplanetary parameter's variations aboard geocentric satellites in the period January 1972-July 1974 are analysed and grouped according to their correlation among them. From this analysis of about 30 cases it came out that the majority of the depressions correlates with the average propagation speed of interplanetary shocks as well as with the amplitude of the interplanetary magnetic field after the eruption of a solar flare. About one fourth of the events correlates with corotating fast solar wind streams. As the recovery time of the shock-related depressions depends strongly on the heliographic longitude of the causitive solar flare, it seems that the cosmic ray modulation region has a corotative-like feature. (Auth.)

  15. Towards phasing using high X-ray intensity

    International Nuclear Information System (INIS)

    Galli, Lorenzo; Son, Sang-Kil; Barends, Thomas R. M.; White, Thomas A.; Barty, Anton; Botha, Sabine; Boutet, Sebastien; Caleman, Carl; Doak, R. Bruce; Nanao, Max H.; Nass, Karol; Shoeman, Robert L.; Timneanu, Nicusor; Santra, Robin; Schlichting, Ilme; Chapman, Henry N.

    2015-01-01

    X-ray free-electron lasers (XFELs) show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential 'bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. In conclusion, a pattern sorting scheme is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed

  16. GAMUT: A computer code for γ-ray energy and intensity analysis

    International Nuclear Information System (INIS)

    Firestone, R.B.

    1991-05-01

    GAMUT is a computer code to analyze γ-ray energies and intensities. It does a linear least-squares fit of measured γ-ray energies from one or more experiments to the level scheme. GAMUT also performs a non-linear least-squares analysis of branching intensities. For both energy and intensity data, a statistical Chi-square analysis is performed with an iterative uncertainty adjustment. The uncertainties of outlying measured values and sets of measurements with x 2 /f>1 are increased, and the calculation is repeated until the uncertainties are consistent with the fitted values. GAMUT accepts input from standard or special-format ENSDF data sets. The special-format ENSDF data sets were designed to permit analysis of more than one set of measurements associated with a single ENSDF data set. GAMUT prepares a standard ENSDF format output data set containing the adjusted values. If more than one input ENSDF data set is provided, GAMUT creates an ADOPTED LEVELS, GAMMAS data set containing the adjusted level and γ-ray energies and branching intensities from each level normalized to 100 for the strongest γ-ray. GAMUT also provides a summary of the results and an extensive log of the iterative analysis. GAMUT is interactive prompting the user for input and output file names and for default calculation options. This version of GAMUT has adjustable dimensions so that any maximum number of data sets, levels, and γ-rays can be established at the time of implementation. 6 refs

  17. Femtosecond response of polyatomic molecules to ultra-intense hard X-rays.

    Science.gov (United States)

    Rudenko, A; Inhester, L; Hanasaki, K; Li, X; Robatjazi, S J; Erk, B; Boll, R; Toyota, K; Hao, Y; Vendrell, O; Bomme, C; Savelyev, E; Rudek, B; Foucar, L; Southworth, S H; Lehmann, C S; Kraessig, B; Marchenko, T; Simon, M; Ueda, K; Ferguson, K R; Bucher, M; Gorkhover, T; Carron, S; Alonso-Mori, R; Koglin, J E; Correa, J; Williams, G J; Boutet, S; Young, L; Bostedt, C; Son, S-K; Santra, R; Rolles, D

    2017-06-01

    X-ray free-electron lasers enable the investigation of the structure and dynamics of diverse systems, including atoms, molecules, nanocrystals and single bioparticles, under extreme conditions. Many imaging applications that target biological systems and complex materials use hard X-ray pulses with extremely high peak intensities (exceeding 10 20 watts per square centimetre). However, fundamental investigations have focused mainly on the individual response of atoms and small molecules using soft X-rays with much lower intensities. Studies with intense X-ray pulses have shown that irradiated atoms reach a very high degree of ionization, owing to multiphoton absorption, which in a heteronuclear molecular system occurs predominantly locally on a heavy atom (provided that the absorption cross-section of the heavy atom is considerably larger than those of its neighbours) and is followed by efficient redistribution of the induced charge. In serial femtosecond crystallography of biological objects-an application of X-ray free-electron lasers that greatly enhances our ability to determine protein structure-the ionization of heavy atoms increases the local radiation damage that is seen in the diffraction patterns of these objects and has been suggested as a way of phasing the diffraction data. On the basis of experiments using either soft or less-intense hard X-rays, it is thought that the induced charge and associated radiation damage of atoms in polyatomic molecules can be inferred from the charge that is induced in an isolated atom under otherwise comparable irradiation conditions. Here we show that the femtosecond response of small polyatomic molecules that contain one heavy atom to ultra-intense (with intensities approaching 10 20 watts per square centimetre), hard (with photon energies of 8.3 kiloelectronvolts) X-ray pulses is qualitatively different: our experimental and modelling results establish that, under these conditions, the ionization of a molecule is

  18. Pyroelectric composite for detection of X-ray intensity

    International Nuclear Information System (INIS)

    Sakamoto, Walter Katsumi; Estevam, Giuliano Pierre; Carvalho, Aparecido Augusto de; Pontes, Wesley; Paula, Mauro Henrique de

    2010-01-01

    Composite material obtained with modified lead titanate (Pz34) ferroelectric ceramic and polyether-ether-ketone (PEEK) polymer matrix was used as sensitive component to measure X-ray intensity in a novel detection system. The sensing element works as a thermal transducer, converting a non-quantified thermal flux into an output measurable quantity of electrical voltage. The samples were obtained up to 60 vol.% of ceramic, by hot pressing the mixture of Pz34 and PEEK powders at 368 deg C and applying 12 MPa pressure for 2.0 h. The sensor response varies from 2.70 V to 0.80 V in the energy fluence rate range of 6.30 to 37.20 W/m 2 . The absorbed incident energy was analyzed as a function of the ionizing energy. Furthermore, by measuring the pyroelectric activity of the composite film it was observed that there is no degradation of the sensor after the irradiation. (author)

  19. Rotation of the Earth, solar activity and cosmic ray intensity

    Energy Technology Data Exchange (ETDEWEB)

    Barlyaeva, T.; Bard, E. [Aix-Marseille Univ., CNRS, IRD, Aix-en-Provence (France). CEREGE, College de France; Abarca-del-Rio, R. [Universidad de Concepcion (UDEC) (Chile). Dept. de Geofisica (DGEO)

    2014-10-01

    We analyse phase lags between the 11-year variations of three records: the semi-annual oscillation of the length of day (LOD), the solar activity (SA) and the cosmic ray intensity (CRI). The analysis was done for solar cycles 20-23. Observed relationships between LOD, CRI and SA are discussed separately for even and odd solar cycles. Phase lags were calculated using different methods (comparison of maximal points of cycles, maximal correlation coefficient, line of synchronization of cross-recurrence plots). We have found different phase lags between SA and CRI for even and odd solar cycles, confirming previous studies. The evolution of phase lags between SA and LOD as well as between CRI and LOD shows a positive trend with additional variations of phase lag values. For solar cycle 20, phase lags between SA and CRI, between SA and LOD, and between CRI and LOD were found to be negative. Overall, our study suggests that, if anything, the length of day could be influenced by solar irradiance rather than by cosmic rays.

  20. Rotation of the Earth, solar activity and cosmic ray intensity

    International Nuclear Information System (INIS)

    Barlyaeva, T.; Bard, E.

    2014-01-01

    We analyse phase lags between the 11-year variations of three records: the semi-annual oscillation of the length of day (LOD), the solar activity (SA) and the cosmic ray intensity (CRI). The analysis was done for solar cycles 20-23. Observed relationships between LOD, CRI and SA are discussed separately for even and odd solar cycles. Phase lags were calculated using different methods (comparison of maximal points of cycles, maximal correlation coefficient, line of synchronization of cross-recurrence plots). We have found different phase lags between SA and CRI for even and odd solar cycles, confirming previous studies. The evolution of phase lags between SA and LOD as well as between CRI and LOD shows a positive trend with additional variations of phase lag values. For solar cycle 20, phase lags between SA and CRI, between SA and LOD, and between CRI and LOD were found to be negative. Overall, our study suggests that, if anything, the length of day could be influenced by solar irradiance rather than by cosmic rays.

  1. Intensity variation of cosmic rays near the heliospheric current sheet

    International Nuclear Information System (INIS)

    Badruddin, K.S.; Yadav, R.S.; Yadav, N.R.

    1985-01-01

    Cosmic ray intensity variations near the heliospheric current sheet-both above and below it-have been studied during 1964-76. Superposed epoch analysis of the cosmic ray neutron monitor data with respect to sector boundaries (i.e., heliospheric current sheet crossings) has been performed. In this analysis data from neutron monitors well distributed in latitude over the Earth's surface is used. First, this study has been made during the two solar activity minimum periods 1964-65 and 1975-76, using the data from Thule (cut-off rigidity O GV), Deep River (cut-off rigidity 1.02 GV), Rome (cut-off rigidity 6.32 GV) and Huancayo (cut-off rigidity 13.45 GV) neutron monitors. The data is analyzed from Deep River, Rome and Huancayo neutron monitors, for which data is available for the full period (1964-76), by dividing the periods according to the changes in solar activity, interplanetary magnetic field polarity and coronal holes. All these studies have shown a negative gradient with respect to heliomagnetic latitude (current sheet). These results have been discussed in the light of theoretical and observational evidences. Suggestions have been given to overcome the discrepancy between the observational and theoretical results. Further, possible explanations for these observational results have been suggested. (author)

  2. Long-term Modulation of Cosmic Ray Intensity in relation to Sunspot ...

    Indian Academy of Sciences (India)

    it should be more closely connected with cosmic ray modulation than with other solar characteristics (sunspot numbers or coronal emission intensity). The intensity of galactic cosmic rays varies inversely with sunspot numbers, having their maximum intensity at the minimum of the 11-year sunspot cycle (Forbush 1954, 1958) ...

  3. Characteristics of ionization chambers for intense pulsed x-rays and Co-60 #betta#-rays, (2)

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okabe, Shigeru; Fukuda, Kyue; Furuta, Junichiro; Fujino, Takahiro

    1981-01-01

    Mean ionization currents and pulse figures of parallel plate ionization chambers enclosed with various gases were measured when they were exposed to intense pulsed X-rays and continuous #betta#-rays. Relation between the measured ionization current and the intensity of X-rays was obtained at the applied voltage of 1000 V. In the case of intense pulsed X-rays, ionization current was smaller in comparison with the case of continuous #betta#-rays, under the X-rays of equal intensity. Pulse figures were observed with chambers which were filled with the gases of air and O 2 and they are considered to be caused by the free electrons of these gases. In these cases, polarity effects of the electric field on the pulse figures were not recognized. Various figures and their changes were also observed from chambers filled with He, Ne, N 2 , Ar, kr, and Xe, respectively. Polarity effects were recognized on those pulse figures. (author)

  4. Neuromuscular Strain Increases Symptom Intensity in Chronic Fatigue Syndrome.

    Directory of Open Access Journals (Sweden)

    Peter C Rowe

    Full Text Available Chronic fatigue syndrome (CFS is a complex, multisystem disorder that can be disabling. CFS symptoms can be provoked by increased physical or cognitive activity, and by orthostatic stress. In preliminary work, we noted that CFS symptoms also could be provoked by application of longitudinal neural and soft tissue strain to the limbs and spine of affected individuals. In this study we measured the responses to a straight leg raise neuromuscular strain maneuver in individuals with CFS and healthy controls. We randomly assigned 60 individuals with CFS and 20 healthy controls to either a 15 minute period of passive supine straight leg raise (true neuromuscular strain or a sham straight leg raise. The primary outcome measure was the symptom intensity difference between the scores during and 24 hours after the study maneuver compared to baseline. Fatigue, body pain, lightheadedness, concentration difficulties, and headache scores were measured individually on a 0-10 scale, and summed to create a composite symptom score. Compared to individuals with CFS in the sham strain group, those with CFS in the true strain group reported significantly increased body pain (P = 0.04 and concentration difficulties (P = 0.02 as well as increased composite symptom scores (all P = 0.03 during the maneuver. After 24 hours, the symptom intensity differences were significantly greater for the CFS true strain group for the individual symptom of lightheadedness (P = 0.001 and for the composite symptom score (P = 0.005. During and 24 hours after the exposure to the true strain maneuver, those with CFS had significantly higher individual and composite symptom intensity changes compared to the healthy controls. We conclude that a longitudinal strain applied to the nerves and soft tissues of the lower limb is capable of increasing symptom intensity in individuals with CFS for up to 24 hours. These findings support our preliminary observations that increased mechanical

  5. The use of a CCD imaging system for X-ray film intensity measurement

    International Nuclear Information System (INIS)

    Grigg, M.W.; Barnea, Z.

    1994-01-01

    The use of a simple CCD-based imaging system for digitizing and x-ray film image is demonstrated. A method of extending the region of linear response of the film based upon an analytic representation of the observed response to a series of increasing exposures is described. The validity of the procedure is illustrated through an example of the absolute intensity measurement of a reflection of cadmium sulphide. 3 refs., 7 figs

  6. Overview of high intensity x-ray and gamma-ray sources

    International Nuclear Information System (INIS)

    Prestwich, K.R.; Lee, J.R.; Ramirez, J.J.; Sanford, T.W.L.; Agee, F.J.; Frazier, G.B.; Miller, A.R.

    1987-01-01

    The requirements for intense x-ray and gamma-ray sources to simulate the radiation effects from nuclear weapons has led to the development of several types of terawatt-pulsed power systems. One example of a major gamma-ray source is Aurora, a 10-MV, 1.6-MA, 120-ns four-module, electron-beam generator. Recent requirements to improve the dose rate has led to the Aurora upgrade program and to the development of the 20-MV, 800-kA, 40-ns Hermes-III electron-beam accelerator. The Aurora program includes improvements to the pulsed power system and research on techniques to improve the pulse shape of the electron beam. Hermes III will feature twenty 1-MV, 800-kA induction accelerator cavities supplying energy to a magnetically insulated transmission line adder. Hermes III will become operational in 1988. Intense x-ray sources consist of pulsed power systems that operate with 1-MV to 2-MV output voltages and up to 25-TW output powers. These high powers are achieved with either low impedance electron-beam generators or multimodular pulsed power systems. The low-impedance generators have high voltage Marx generators that store the energy and then sequentially transfer this energy to pulse-forming transmission lines with lower and lower impedance until the high currents are reached. In the multimode machines, each module produces 0.7-TW to 4-TW output pulses, and all of the modules are connected together to supply energy to a single diode

  7. Interplanetary magnetic field associated changes in cosmic ray intensity and geomagnetic field during 1973-75

    International Nuclear Information System (INIS)

    Singh, R.L.; Shukla, J.P.; Shukla, A.K.; Sharma, S.M.; Agrawal, S.P.

    1979-01-01

    The effects of interplanetary magnetic field (IMF) B and its Bsub(z) component on cosmic ray intensity and geomagnetic field variations have been examined for the period 1973-75. It is observed that: (1) B >= 10γ (magnetic blobs) is pre-requisite in producing cosmic ray intensity and geomagnetic field variations of varying magnitudes, (2) the longer existence of magnetic blobs on successive days produces larger decreases in cosmic ray intensity and geomagnetic field and (3) the southward component (Bsub(z)) of IMF generally gives rise to large Asub(p) changes, though it is not effective in producing cosmic ray intensity decreases. (auth.)

  8. Using prepulsing: a useful way for increasing absorption efficiency of high intensity laser beam

    International Nuclear Information System (INIS)

    Peng Huimin; Zhang Guoping; Sheng Jiatian

    1990-01-01

    Using prepulse to irradiate target for increasing absorption efficiency of high intensity incident laser beam is considered and some theoretical simulations have been done. 1-D non-LTE radiative hydrodynamic code is used to simulate the interactions of laser beam with matter. A gaussian laser prepulse of wavelength 1.06 μm, FWHM 600 ps and peak intensity 1.5 x 10 12 W/cm 2 was used to irradiate 20 μm thick Au plate target, after 3ns a main gaussian pulse with wavelength 1.06 μm, FWHM 600 ps and peak intensity 3.0 x 10 14 W/cm 2 irradiated the expanding Au plasma. The responces of laser-produced plasma conditions are shown. By comparing with without prepulsing, under the condition of same main incident laser pulse, the absorption efficiency is increased from 0.36 to 0.60 and the laser-x-ray conversion efficiency is increased from 0.16 to 0.25. The electron temperature of hot plasma is also higher than without prepulsing, and the x-ray spectrum which is emitted from laser-produced hot plasma is harder and more intense than without prepulsing. The responces of laser-produced plasma for Fe target with prepulsing are shown as well. The conclusion is that using prepulsing is a useful way for getting high absorption laser beam

  9. Instrumentation for continuous monitoring of low energy cosmic ray intensity

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S; Prasad, R; Yadav, R S [Aligarh Muslim Univ. (India). Dept. of Physics; Naqvi, T H [Z.H. Engineering Coll., Aligarh (India); Ahmed, Rais [National Council of Educational Research and Training, New Delhi (India)

    1975-12-01

    A high counting rate neutron monitor developed at Aligarh for continuous monitoring of low energy nucleonic component of cosmic rays is described. Transistorized electronic circuits used are described.

  10. Linear luminescence for thin plastic scintillator under intense soft X-ray irradiation

    International Nuclear Information System (INIS)

    Ning Jiamin; Jiang Shilun; Xu Rongkun; Guo Cun

    2006-01-01

    The basic principle of soft X-ray power meter is introduced in the paper and the experimental process and the result of thin plastic scintillator linear luminescence under intense soft X-ray irradiation are described. A range of flux density of energy for thin plastic scintillator linear luminescence under intense soft X-ray irradiation is included. The upper limit of the flux density is 1.47 x 10 5 W/cm 2 . (authors)

  11. Instrumentation for continuous monitoring of low energy cosmic ray intensity

    International Nuclear Information System (INIS)

    Kumar, S.; Prasad, R.; Yadav, R.S.; Ahmed, Rais

    1975-01-01

    A high counting rate neutron monitor developed at Aligarh for continuous monitoring of low energy nucleonic component of cosmic rays is described. Transistorized electronic circuits used are described. (author)

  12. Decreasing of pulsation intensity levels in X-ray receivers

    CERN Document Server

    Dvoryankin, V F; Kudryashov, A A; Petrov, A G

    2002-01-01

    The low frequency filter is applied in the multichannel receiver on the basis of the GaAs epitaxial structures for decreasing the pulsations level at the signals amplifier outlet. The optimal band of the filter is determined by the transition processes by the detector scanning in the roentgen beams. The X-ray source of radiation with the medium-frequency feeding generator is used for verifying the quality of the obtained X-ray image

  13. High-intensity laser synchrotron x-ray source

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1995-10-01

    A laser interacting with a relativistic electron beam behaves like a virtual wiggler of an extremely short period equal to half of the laser wavelength. This approach opens a route to relatively compact, high-brightness x-ray sources alternative or complementary to conventional synchrotron light sources. Although not new, the Laser Synchrotron Light Source (LSLS) concept is still waiting for a convincing demonstration. Available at the BNL's Accelerator Test Facility (ATF), a high-brightness electron beam and the high-power C0 2 laser may be used as prototype LSLS brick stones. In a feasible demonstration experiment, 10-GW, 100-ps C0 2 laser beam will be brought to a head-on collision with a 10-ps, 0.5-nC, 70 MeV electron bunch. Flashes of well-collimated, up to 9.36-keV (∼ Angstrom) x-rays of 10-ps pulse duration, with a flux of ∼10 19 photons/sec will be produced via linear Compton backscattering. The x-ray spectrum is tunable proportionally to a variable e-beam energy. A natural short-term extension of the proposed experiment would be further enhancement of the x-ray flux to a 10 21 -10 22 photons/sec level, after the ongoing ATF CO 2 laser upgrade to 1 TW peak power and electron bunch shortening to 3 ps. The ATF LSLS x-ray beamline, exceeding by orders of magnitude the peak fluxes attained at the National Synchrotron Light Source (NSLS) x-ray storage ring, may become attractive for certain users, e.g., for biological x-ray microscopy. In addition, a terawatt CO 2 laser will enable harmonic multiplication of the x-ray spectrum via nonlinear Compton scattering

  14. MCS precipitation and downburst intensity response to increased aerosol concentrations

    Science.gov (United States)

    Clavner, M.; Cotton, W. R.; van den Heever, S. C.

    2015-12-01

    Mesoscale convective systems (MCSs) are important contributors to rainfall in the High Plains of the United States as well as producers of severe weather such as hail, tornados and straight-line wind events known as derechos. Past studies have shown that changes in aerosol concentrations serving as cloud condensation nuclei (CCN) alter the MCS hydrometeor characteristics which in turn modify precipitation yield, downdraft velocity, cold-pool strength, storm propagation and the potential for severe weather to occur. In this study, the sensitivity of MCS precipitation characteristics and convective downburst velocities associated with a derecho to changes in CCN concentrations were examined by simulating a case study using the Regional Atmospheric Modeling System (RAMS). The case study of the 8 May 2009 "Super-Derecho" MCS was chosen since it produced a swath of widespread wind damage in association with an embedded large-scale bow echo, over a broad region from the High Plains of western Kansas to the foothills of the Appalachians. The sensitivity of the storm to changes in CCN concentrations was examined by conducting a set of three simulations which differed in the initial aerosol concentration based on output from the 3D chemical transport model, GEOS-Chem. Results from this study indicate that while increasing CCN concentrations led to an increase in precipitation rates, the changes to the derecho strength were not linear. A moderate increase in aerosol concentration reduced the derecho strength, while the simulation with the highest aerosol concentrations increased the derecho intensity. These changes are attributed to the impact of enhanced CCN concentration on the production of convective downbursts. An analysis of aerosol loading impacts on these MCS features will be presented.

  15. Simulation of intense laser-dense matter interactions. X-ray production and laser absorption

    Energy Technology Data Exchange (ETDEWEB)

    Ueshima, Yutaka; Kishimoto, Yasuaki; Sasaki, Akira [Japan Atomic Energy Research Inst., Neyagawa, Osaka (Japan). Kansai Research Establishment; Sentoku, Yasuhiko; Tajima, Toshiki

    1998-03-01

    The development of short-pulse ultra high intensity lasers will enable us to generate short-pulse intense soft and hard X-rays. Acceleration of an electron in laser field generates intense illuminated located radiation, Larmor radiation, around KeV at 10{sup 18} W/cm{sup 2} with 100 TW and 1 {mu}m wave length laser. The Coulomb interaction between rest ions and relativistic electron generates broad energy radiation, bremsstrahlung emission, over MeV at 10{sup 18} W/cm{sup 2} with the same condition. These intense radiations come in short pulses of the same order as that of the irradiated laser. The generated intense X-rays, Larmor and bremsstrahlung radiation, can be applied to sources of short pulse X-ray, excitation source of inner-shell X-ray laser, position production and nuclear excitation, etc. (author)

  16. K and L X-ray emission intensities of some radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Verma, H R; Pal, D [Punjabi Univ., Patiala (India). Dept. of Physics

    1985-01-01

    The K and L x-ray emission intensities per 100 disintegrations have been calculated for some radionuclides using the latest adopted data for gamma-ray intensities, electron capture and internal conversion coefficients for the parent nuclides, fluorescence yield values, Coster-Kronig transition probabilities, average total number of primary L shell vacancies produced in the decay of K shell vacancies and emission rates for various shells and subshells for the daughter nuclei. The results are in good agreement with theoretical and experimental values for the K x-ray intensities. There are no experimental results available to compare with the present calculations for the L x-ray intensities; however, there is a marked discrepancy in the L..cap alpha.. and L..beta.. intensities available on the basis of theoretical estimates.

  17. Solar activity effects on cosmic ray intensity and geomagnetic field variation

    International Nuclear Information System (INIS)

    Shukla, A.K.; Shukla, J.P.; Sharma, S.M.; Singh, R.L.; Agrawal, S.P.

    1978-01-01

    An analysis has been performed to statistically correlate the date of solar flare occurrence and its importance with the short term cosmic ray intensity decreases (observed by the high latitude neutron monitors) as well as with the geomagnetic field fluctuation indices (Asub(p) and Dsub(st)), during the period 1973-1976. This period has the particular advantage of being close to a solar minimum to avoid the ambiguity due to closely spaced solar flares. It is found that the intensity decrease starts at least 2-3 days after the date of bright solar flares of Imp 1B, 2B or 3B and the amplitude of the decrease increases with the importance of the solar flare. (author)

  18. Reconstructing the long-term cosmic ray intensity: linear relations do not work

    Directory of Open Access Journals (Sweden)

    K. Mursula

    2003-04-01

    Full Text Available It was recently suggested (Lockwood, 2001 that the cosmic ray intensity in the neutron monitor energy range is linearly related to the coronal source flux, and can be reconstructed for the last 130 years using the long-term coronal flux estimated earlier. Moreover, Lockwood (2001 reconstructed the coronal flux for the last 500 years using a similar linear relation between the flux and the concentration of cosmogenic 10 Be isotopes in polar ice. Here we show that the applied linear relations are oversimplified and lead to unphysical results on long time scales. In particular, the cosmic ray intensity reconstructed by Lockwood (2001 for the last 130 years has a steep trend which is considerably larger than the trend estimated from observations during the last 65 years. Accordingly, the reconstructed cosmic ray intensity reaches or even exceeds the local interstellar cosmic ray flux around 1900. We argue that these unphysical results obtained when using linear relations are due to the oversimplified approach which does not take into account the complex and essentially nonlinear nature of long-term cosmic ray modulation in the heliosphere. We also compare the long-term cosmic ray intensity based on a linear treatment with the reconstruction based on a recent physical model which predicts a considerably lower cosmic ray intensity around 1900.Key words. Interplanetary physics (cosmic rays; heliopause and solar wind termination – Geomagnetism and paleomagnetism (time variations, secular and long-term

  19. Modelling cosmic ray intensities along the Ulysses trajectory

    Directory of Open Access Journals (Sweden)

    D. C. Ndiitwani

    2005-03-01

    Full Text Available Time dependent cosmic ray modulation in the inner heliosphere is studied by comparing results from a 2-D, time-dependent cosmic ray transport model with Ulysses observations. A compound approach, which combines the effects of the global changes in the heliospheric magnetic field magnitude with drifts to establish a realistic time-dependence, in the diffusion and drift coefficients, are used. We show that this model results in realistic cosmic ray modulation from the Ulysses launch (1990 until recently (2004 when compared to 2.5-GV electron and proton and 1.2-GV electron and Helium observations from this spacecraft. This approach is also applied to compute radial gradients present in 2.5-GV cosmic ray electron and protons in the inner heliosphere. The observed latitude dependence for both positive and negative charged particles during both the fast latitude scan periods, corresponding to different solar activity conditions, could also be realistically computed. For this an additional reduction in particle drifts (compared to diffusion toward solar maximum is needed. This results in a realistic charge-sign dependent modulation at solar maximum and the model is also applied to predict charge-sign dependent modulation up to the next expected solar minimum.

  20. Investigation into increasing short-duration rainfall intensities in ...

    African Journals Online (AJOL)

    2015-04-03

    Apr 3, 2015 ... This study explores this expectation by using historical short-duration ... weather station 5-min rainfall data were combined to extend the effective ... evidence was found of trends or indications of changes in rainfall intensities.

  1. X-ray polarization measurements at relativistic laser intensities

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Shepherd, R.; Mancini, R.C.

    2004-01-01

    An effort has been started to measure the short pulse laser absorption and energy partition at relativistic laser intensities up to 10 21 W/cm 2 . Plasma polarization spectroscopy is expected to play an important role in determining fast electron generation and measuring the electron distribution function. (author)

  2. Free-air ionization intensity in the lower atmosphere due to cosmic-ray

    International Nuclear Information System (INIS)

    Urabe, Itsumasa; Katsurayama, Kousuke

    1979-01-01

    Being able to be determined by subtracting the gamma-ray ionization intensity from that obtained with ionization chamber, cosmic-ray ionization intensity in free air was estimated by using with 15l air-filled ionization chamber and 3''diameter spherical NaI(Tl) scintillation spectrometer. Optimum applied voltage to 15l air-filled ionization chamber was determined in accordance with Scott and Greening's formula to obtain the ionization intensity caused by gamma-rays and cosmic-rays. Pulse-height distribution of cosmic-rays created in 3''diameter spherical NaI(Tl) scintillation spectrometer was investigated for the precise determination of gamma-ray ionization intensity. Field measurements were carried out by using with these two instruments at about 1.5 meter above the ground in the several locations around Research Reactor Institute of Kyoto University. Cosmic-ray ionization intensity in free air was estimated from the results obtained with air-filled ionization chamber and was 3.33 +- 0.15 μR/hr equivalent in natural environment near Research Reactor Institute of Kyoto University. (author)

  3. Kβ/ Kα intensity ratios for X-ray production in 3d metals by gamma-rays and protons

    Science.gov (United States)

    Bhuinya, C. R.; Padhi, H. C.

    1994-04-01

    Systematic measurements of Kβ/ Kα intensity ratios for X-ray production in 3d metals have been carried out using γ-ray and fast proton ionization methods. The measured ratios from proton ionization experiments indicate production of multivacancies in the L shell giving rise to higher Kβ/ Kα ratios compared to the present γRF results and 2 MeV proton ionization results of Perujo et al. [Perujo A., Maxwell J. A., Teesdale W. J. and Cambell J. L. (1987) J. Phys. B: Atom. Molec. Phys.20, 4973]. This is consistent with the SCA model calculation which gives increased simultaneous K- and L-shell ionization at 4 MeV. The present results from γRF experiments are in close agreement with the 2 MeV proton ionization results of Perujo et al. (1987) and also with the theoretical calculation of jankowski and Polasik [Jankowski K. and Polasik M. (1989) J. Phys. B: Atom. Molec. Optic. Phys. 22, 2369] but the theoretical results of Scofield [Scofield J. H. (1974a) Atom. Data Nucl. Data Tables14, 12] are somewhat higher.

  4. Vulnerability Assessment of Housing Damage in the Philippines Due to an Increase Increase in Typhoon Intensity

    Science.gov (United States)

    Esteban, Miguel; Stromberg, Per; Gasparatos, Alexandros

    2010-05-01

    It is currently feared that the increase in surface sea temperature resulting from increasing level of greenhouse gases in the atmosphere could result in higher tropical cyclone intensity in the future. Although the vulnerability of infrastructure and economic systems have been studied for a number of developed countries, very little work has been done on developing countries. The present work first attempts to evaluate the vulnerability of different regions in the Philippines to the passage of tropical cyclones. To this effect a total of 22 typhoons and tropical storms that affected the Philippines were analysed for the period 2003-2008. The data used was collected by the National Disaster Coordinating Council of the Philippines, who issue "SitRep" NDCC Reports after each major storm. This agency provides damage data for each region, including number of casualties, affected people, damaged and destroyed houses, and losses in the infrastructure and agriculture. The likely economic effects of increased typhoon intensity by using a Monte Carlo Simulation that magnifies the intensity of historical tropical cyclones between the years 1978 and 2008 to simulate the economic damage by 2085. The methodology used is based on the work of Esteban et al. (2009), which in turn uses the results of Knutson and Tuleya (2004) for the estimation of the increase in tropical cyclone intensity in 2085. The results show that downtime could increase from a national 1% to 1.3% by 2050 if economic and population growth are taken into account (29 to 36bn USD, from a total GDP of 2,757bn USD by 2050). If these are ignored the time lost each year can be estimated to cost around 630m USD (PPP) for the control scenario, which could increase to between 766m or 945mm USD by the year 2085 for the two different scenarios considered. This indirect damage depends on the geographical location and is for example higher in some areas of the northern island of Luzon, while the island of Mindanao in the

  5. Tolerance limits of X-ray image intensity

    International Nuclear Information System (INIS)

    Stargardt, A.; Juran, R.; Brandt, G.A.

    1985-01-01

    Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author)

  6. THE RESULTS OF PROFESSIONAL APPROACH AND INCREASED INTENSITY OF WORK

    Directory of Open Access Journals (Sweden)

    Georgi Georgiev

    2014-06-01

    Full Text Available Introduction: The goal of the research is to establish if the professional approach and increased intensity of applied results in improvements and differences between the functional and motoric abilities (skills and habits with students. Methods: The research has been conducted on a sample of 76 students at the age of 14. The first subsample consists of 40 students, and the second of 36 students, who, along with their regular school classes of 3 times a week and additional sports subject as choice (this refers to the first subsample as well, had regular trainings in basketball clubs three hours a week. They were tested by three indexes: 1 motoric abilities; 2 motoric skills and habits (Majeric, 2004; and 3 functional abilities (Jovanovic, 1999. There were calculated: basic descriptive statistic parameters, t-tests of independent samples, analysis of variance and Friedman test (Bala, 1986. Results: The results of the analyses are represented in 8 tables. On the base of the obtained results, the conclusion is that better results in all three indexes, are determined with the second subsample. It is those who are involved in regular school classes, have the sport as their additional subject choice, and had an active training work in their sports clubs. Discussion: The authors general conclusion of the research is that the number of that kind of research approach is quite small The results of the analyses of the first index in the conducted research show great similarity with the results obtained in the research of Georgiev, Kostovski, & Mitrevski (2012. The results of the second index indicate great similarity with Mitrevski’s research (2012. The results of the third index are logically sustained. They are better with the second subsample. References: Bala G (1986. Logicke osnove metoda za analizu podataka iz istrazivanja u fizickoj kulturi. Novi Sad, Sava Muncan. Georgiev G, Kostovski Z, Mitrevski V (2012. Sport Mont, 34-36, 105-9. Jovanovic G

  7. X-ray diagnosis of pneumothorax in intensive care units

    International Nuclear Information System (INIS)

    Galanski, M.; Hartenauer, U.; Krumme, B.

    1981-01-01

    Pneumothorax is the most severe manifestation of pulmonary barotrauma which occurs in mechanical ventilation. Diagnosis of pneumothorax in intensive care radiology is of particular difficulty. Chest radiographs in supine position show a variety of signs which may be helpful but are not conclusive. There are different techniques for verification of ventrally located pneumothorax. 45 0 tangential radiographs of the hemithorax in question are most conclusive for demonstration of extrapulmonary air located inside the pleural cavity. This 45 0 technique is easy to carry out without changing the patients position. (orig.) [de

  8. Two electron response to an intense x-ray free electron laser pulse

    International Nuclear Information System (INIS)

    Moore, L R; Parker, J S; Meharg, K J; Armstrong, G S J; Taylor, K T

    2009-01-01

    New x-ray free electron lasers (FELs) promise an ultra-fast ultra-intense regime in which new physical phenomena, such as double core hole formation in at atom, should become directly observable. Ahead of x-ray FEL experiments, an initial key task is to theoretically explore such fundamental laser-atom interactions and processes. To study the response of a two-electron positive ion to an intense x-ray FEL pulse, our theoretical approach is a direct numerical integration, incorporating non-dipole Hamiltonian terms, of the full six-dimensional time-dependent Schroedinger equation. We present probabilities of double K-shell ionization in the two-electron positive ions Ne 8+ and Ar 16+ exposed to x-ray FEL pulses with frequencies in the range 50 au to 300 au and intensities in the range 10 17 to 10 22 W/cm 2 .

  9. Two electron response to an intense x-ray free electron laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Moore, L R; Parker, J S; Meharg, K J; Armstrong, G S J; Taylor, K T, E-mail: l.moore@qub.ac.u [DAMTP, David Bates Building, Queen' s University Belfast, Belfast, BT7 1NN (United Kingdom)

    2009-11-01

    New x-ray free electron lasers (FELs) promise an ultra-fast ultra-intense regime in which new physical phenomena, such as double core hole formation in at atom, should become directly observable. Ahead of x-ray FEL experiments, an initial key task is to theoretically explore such fundamental laser-atom interactions and processes. To study the response of a two-electron positive ion to an intense x-ray FEL pulse, our theoretical approach is a direct numerical integration, incorporating non-dipole Hamiltonian terms, of the full six-dimensional time-dependent Schroedinger equation. We present probabilities of double K-shell ionization in the two-electron positive ions Ne{sup 8+} and Ar{sup 16+} exposed to x-ray FEL pulses with frequencies in the range 50 au to 300 au and intensities in the range 10{sup 17} to 10{sup 22} W/cm{sup 2}.

  10. The high intensity {gamma}-ray source (HI{gamma}S) and recent results

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, A.P. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States)]. E-mail: tonchev@tunl.duke.edu; Boswell, M. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Howell, C.R. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Kelley, J.H. [North Carolina State University and TUNL, Raleigh, NC 27695 (United States); Tornow, W. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Wu, Y.K. [Duke University and Duke Free Electron Laser Laboratory, Durham, NC 27708-0319 (United States)

    2005-12-15

    The high intensity {gamma}-ray source (HI{gamma}S) utilizes intra-cavity backscattering of free electron laser photons from the Duke electron storage ring to produce a unique monoenergetic beam of high-flux {gamma}-rays with high polarization and selectable energy resolution. At present, {gamma}-ray beams with energies from 2 to 58 MeV are available with intensities as high as 10{sup 5}-5 x 10{sup 6} {gamma}/s, energy spreads of 3% or better, and nearly 100% linear polarization. The quality and intensity of the {gamma}-ray beams at HI{gamma}S are responsible for the unprecedented performance of this facility in a broad range of research programs in nuclear structure, nuclear astrophysics and nuclear applications. Recent results from excitation of isomeric states in ({gamma}, n) reactions and parity assignments of dipole states determined via the ({gamma}, {gamma}') reaction are presented.

  11. Intensity-Modulated Advanced X-ray Source (IMAXS) for Homeland Security Applications

    International Nuclear Information System (INIS)

    Langeveld, Willem G. J.; Johnson, William A.; Owen, Roger D.; Schonberg, Russell G.

    2009-01-01

    X-ray cargo inspection systems for the detection and verification of threats and contraband require high x-ray energy and high x-ray intensity to penetrate dense cargo. On the other hand, low intensity is desirable to minimize the radiation footprint. A collaboration between HESCO/PTSE Inc., Schonberg Research Corporation and Rapiscan Laboratories, Inc. has been formed in order to design and build an Intensity-Modulated Advanced X-ray Source (IMAXS). Such a source would allow cargo inspection systems to achieve up to two inches greater imaging penetration capability, while retaining the same average radiation footprint as present fixed-intensity sources. Alternatively, the same penetration capability can be obtained as with conventional sources with a reduction of the average radiation footprint by about a factor of three. The key idea is to change the intensity of the source for each x-ray pulse based on the signal strengths in the inspection system detector array during the previous pulse. In this paper we describe methods to accomplish pulse-to-pulse intensity modulation in both S-band (2998 MHz) and X-band (9303 MHz) linac sources, with diode or triode (gridded) electron guns. The feasibility of these methods has been demonstrated. Additionally, we describe a study of a shielding design that would allow a 6 MV X-band source to be used in mobile applications.

  12. Solar cycle variation of cosmic ray intensity along with interplanetary and solar wind plasma parameters

    International Nuclear Information System (INIS)

    Mishra, R.K.; Tiwari, S.; Agarwal, R.

    2008-01-01

    Galactic cosmic rays are modulated at their propagation in the heliosphere by the effect of the large-scale structure of the interplanetary medium. A comparison of the variations in the cosmic ray intensity data obtained by neutron monitoring stations with those in geomagnetic disturbance, solar wind velocity (V), interplanetary magnetic field (B), and their product (V , B) near the Earth for the period 1964-2004 has been presented so as to establish a possible correlation between them. We used the hourly averaged cosmic ray counts observed with the neutron monitor in Moscow. It is noteworthy that a significant negative correlation has been observed between the interplanetary magnetic field, product (V , B) and cosmic ray intensity during the solar cycles 21 and 22. The solar wind velocity has a good positive correlation with cosmic ray intensity during solar cycle 21, whereas it shows a weak correlation during cycles 20, 22 and 23. The interplanetary magnetic field shows a weak negative correlation with cosmic rays for solar cycle 20, and a good anti-correlation for solar cycles 21-23 with the cosmic ray intensity, which, in turn, shows a good positive correlation with disturbance time index (Dst) during solar cycles 21 and 22, and a weak correlation for cycles 20 and 23. (Authors)

  13. Performance Characteristics Of An Intensity Modulated Advanced X-Ray Source (IMAXS) For Homeland Security Applications

    International Nuclear Information System (INIS)

    Langeveld, Willem G. J.; Brown, Craig; Condron, Cathie; Ingle, Mike; Christensen, Phil A.; Johnson, William A.; Owen, Roger D.; Hernandez, Michael; Schonberg, Russell G.; Ross, Randy

    2011-01-01

    X-ray cargo inspection systems for the detection and verification of threats and contraband must address stringent, competitive performance requirements. High x-ray intensity is needed to penetrate dense cargo, while low intensity is desirable to minimize the radiation footprint, i.e. the size of the controlled area, required shielding and the dose to personnel. In a collaborative effort between HESCO/PTSE Inc., XScell Corp., Stangenes Industries, Inc. and Rapiscan Laboratories, Inc., an Intensity Modulated Advanced X-ray Source (IMAXS) was designed and produced. Cargo inspection systems utilizing such a source have been projected to achieve up to 2 inches steel-equivalent greater penetration capability, while on average producing the same or smaller radiation footprint as present fixed-intensity sources. Alternatively, the design can be used to obtain the same penetration capability as with conventional sources, but reducing the radiation footprint by about a factor of three. The key idea is to anticipate the needed intensity for each x-ray pulse by evaluating signal strength in the cargo inspection system detector array for the previous pulse. The IMAXS is therefore capable of changing intensity from one pulse to the next by an electronic signal provided by electronics inside the cargo inspection system detector array, which determine the required source intensity for the next pulse. We report on the completion of a 9 MV S-band (2998 MHz) IMAXS source and comment on its performance.

  14. Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging

    International Nuclear Information System (INIS)

    Dong Xue; Niu Tianye; Jia Xun; Zhu Lei

    2012-01-01

    Purpose: X-ray cone-beam CT (CBCT) is being increasingly used for various clinical applications, while its performance is still hindered by image artifacts. This work investigates a new source of reconstruction error, which is often overlooked in the current CBCT imaging. The authors find that the x-ray flat field intensity (I 0 ) varies significantly as the illumination volume size changes at different collimator settings. A wrong I 0 value leads to inaccurate CT numbers of reconstructed images as well as wrong scatter measurements in the CBCT research. Methods: The authors argue that the finite size of x-ray focal spot together with the detector glare effect cause the I 0 variation at different illumination sizes. Although the focal spot of commercial x-ray tubes typically has a nominal size of less than 1 mm, the off-focal-spot radiation covers an area of several millimeters on the tungsten target. Due to the large magnification factor from the field collimator to the detector, the penumbra effects of the collimator blades result in different I 0 values for different illumination field sizes. Detector glare further increases the variation, since one pencil beam of incident x-ray is scattered into an area of several centimeters on the detector. In this paper, the authors study these two effects by measuring the focal spot distribution with a pinhole assembly and the detector point spread function (PSF) with an edge-spread function method. The authors then derive a formula to estimate the I 0 value for different illumination field sizes, using the measured focal spot distribution and the detector PSF. Phantom studies are carried out to investigate the accuracy of scatter measurements and CT images with and without considering the I 0 variation effects. Results: On our tabletop system with a Varian Paxscan 4030CB flat-panel detector and a Varian RAD-94 x-ray tube as used on a clinical CBCT system, the focal spot distribution has a measured full

  15. X-ray luminescence computed tomography imaging via multiple intensity weighted narrow beam irradiation

    Science.gov (United States)

    Feng, Bo; Gao, Feng; Zhao, Huijuan; Zhang, Limin; Li, Jiao; Zhou, Zhongxing

    2018-02-01

    The purpose of this work is to introduce and study a novel x-ray beam irradiation pattern for X-ray Luminescence Computed Tomography (XLCT), termed multiple intensity-weighted narrow-beam irradiation. The proposed XLCT imaging method is studied through simulations of x-ray and diffuse lights propagation. The emitted optical photons from X-ray excitable nanophosphors were collected by optical fiber bundles from the right-side surface of the phantom. The implementation of image reconstruction is based on the simulated measurements from 6 or 12 angular projections in terms of 3 or 5 x-ray beams scanning mode. The proposed XLCT imaging method is compared against the constant intensity weighted narrow-beam XLCT. From the reconstructed XLCT images, we found that the Dice similarity and quantitative ratio of targets have a certain degree of improvement. The results demonstrated that the proposed method can offer simultaneously high image quality and fast image acquisition.

  16. Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection

    International Nuclear Information System (INIS)

    Fernandes, L.M.P.; Antognini, A.; Boucher, M.; Conde, C.A.N.; Huot, O.; Knowles, P.; Kottmann, F.; Ludhova, L.; Mulhauser, F.; Pohl, R.; Schaller, L.A.; Santos, J.M.F. dos; Taqqu, D.; Veloso, J.F.C.A.

    2003-01-01

    The behaviour of large-area avalanche photodiodes for X-rays, visible and vacuum-ultra-violet (VUV) light detection in magnetic fields up to 5 T is described. For X-rays and visible light detection, the photodiode pulse amplitude and energy resolution were unaffected from 0 to 5 T, demonstrating the insensitivity of this type of detector to strong magnetic fields. For VUV light detection, however, the photodiode relative pulse amplitude decreases with increasing magnetic field intensity reaching a reduction of about 24% at 5 T, and the energy resolution degrades noticeably with increasing magnetic field

  17. A calculation model for primary intensity distributions from cylindrically symmetric x-ray lenses

    International Nuclear Information System (INIS)

    Hristov, Dimitre; Maltz, Jonathan

    2008-01-01

    A calculation model for the quantitative prediction of primary intensity fluence distributions obtained by the Bragg diffraction focusing of kilovoltage radiation by cylindrical x-ray lenses is presented. The mathematical formalism describes primary intensity distributions from cylindrically-symmetric x-ray lenses, with a planar isotropic radiation source located in a plane perpendicular to the lens axis. The presence of attenuating medium inserted between the lens and the lens focus is accounted for by energy-dependent attenuation. The influence of radiation scattered within the media is ignored. Intensity patterns are modeled under the assumption that photons that are not interacting with the lens are blocked out at any point of interest. The main characteristics of the proposed calculation procedure are that (i) the application of vector formalism allows universal treatment of all cylindrical lenses without the need of explicit geometric constructs; (ii) intensity distributions resulting from x-ray diffraction are described by a 3D generalization of the mosaic spread concept; (iii) the calculation model can be immediately coupled to x-ray diffraction simulation packages such as XOP and Shadow. Numerical simulations based on this model are to facilitate the design of focused orthovoltage treatment (FOT) systems employing cylindrical x-ray lenses, by providing insight about the influence of the x-ray source and lens parameters on quantities of dosimetric interest to radiation therapy

  18. Intensities of incident and transmitted ultraviolet-a rays through gafchromic films

    Directory of Open Access Journals (Sweden)

    Toshizo Katsuda

    2017-01-01

    Full Text Available Gafchromic films have been applied to X-ray dosimetry in diagnostic radiology. To correct nonuniformity errors in Gafchromic films, X-rays in the double-exposure technique can be replaced with ultraviolet (UV-A rays. Intensities of the incident and transmitted UV-A rays were measured. However, it is unclear whether the chemical color change of Gafchromic films affects the UV-A transmission intensity. Gafchromic EBT3 films were suitable to be used in this study because non-UV protection layers are present on both sides of the film. The film is placed between UV-A ray light-emitting diodes and a probe of a UV meter. Gafchromic EBT3 films were irradiated by UV-A rays for up to 60 min. Data for analysis were obtained in the subsequent 60 min. Images from before and after UV-A irradiation were subtracted. When using 375 nm UV-A, the mean ± standard deviation (SD of the pixel values in the subtracted image was remarkably high (11,194.15 ± 586.63. However, the UV-A transmissivity remained constant throughout the 60 min irradiation period. The mean ± SD UV-A transmission intensity was 184.48 ± 0.50 μm/cm2. Our findings demonstrate that color density changes in Gafchromic EBT3 films do not affect their UV-A transmission. Therefore, Gafchromic films were irradiated by UV-A rays as a preexposure.

  19. Experimental and theoretical studies of the physical processes occurring in thin plane targets irradiated by intense X-ray pulses

    International Nuclear Information System (INIS)

    Bugrov, A. E.; Burdonskii, I. N.; Gavrilov, V. V.; Gol'tsov, A. Yu.; Grabovskii, E. V.; Efremov, V. P.; Zhuzhukalo, E. V.; Zurin, M. V.; Koval'skii, N. G.; Kondrashov, V. N.; Oleinik, G. M.; Potapenko, A. I.; Samokhin, A. A.; Smirnov, V. P.; Fortov, V. E.; Frolov, I. N.

    2007-01-01

    Results are presented from experimental and theoretical studies of the interaction of intense X-ray pulses with different types of plane targets, including low-density (∼10 mg/cm 3 ) ones, in the Angara-5-1 facility. It is found experimentally that a dense low-temperature plasma forms on the target surface before the arrival of the main heating X-ray pulse. It is demonstrated that the contrast of the X-ray pulse can be increased by placing a thin organic film between the target and the discharge gap. The expansion velocity of the plasma created on the target surface irradiated by Z-pinch-produced X rays was found to be (3-4) x 10 6 cm/s. A comparison between the simulation and experimental results confirms the validity of the physical-mathematical model used

  20. Hard X-ray intensity reduction during lower hybrid current drive experiments

    International Nuclear Information System (INIS)

    Mlynar, J.; Stoeckel, J.; Magula, P.

    1993-01-01

    A strong hard X-ray intensity reduction during a standard LHCD at the CASTOR tokamak was studied. From discussion it followed that the magnetic fluctuations level decrease is likely to be responsible for this effect beside the loop voltage decrease. To verify this idea, the connection between the magnetic fluctuation level and the hard X-ray intensity was studied in a nonstandard LHCD regime with a zero loop voltage reduction. These measurements strongly supported the concept that magnetic fluctuations level substantially influences the runaway electrons cross-field transport. Though, more data and a good code for modelling the anomalous transport and hard X-rays production would be of high value. Similar measurements especially for higher RF power should be carried out soon. Besides, the reduction of hard X-rays was observed in the experiments with edge plasma polarization lately; therefore, the magnetic fluctuations level in these experiments should be studied soon. (author) 6 figs., 6 refs

  1. ANALYSIS AND MITIGATION OF X-RAY HAZARD GENERATED FROM HIGH INTENSITY LASER-TARGET INTERACTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, R.; Liu, J.C.; Prinz, A.A.; Rokni, S.H.; Woods, M.; Xia, Z.; /SLAC

    2011-03-21

    Interaction of a high intensity laser with matter may generate an ionizing radiation hazard. Very limited studies have been made, however, on the laser-induced radiation protection issue. This work reviews available literature on the physics and characteristics of laser-induced X-ray hazards. Important aspects include the laser-to-electron energy conversion efficiency, electron angular distribution, electron energy spectrum and effective temperature, and bremsstrahlung production of X-rays in the target. The possible X-ray dose rates for several femtosecond Ti:sapphire laser systems used at SLAC, including the short pulse laser system for the Matter in Extreme Conditions Instrument (peak power 4 TW and peak intensity 2.4 x 10{sup 18} W/cm{sup 2}) were analysed. A graded approach to mitigate the laser-induced X-ray hazard with a combination of engineered and administrative controls is also proposed.

  2. Solar flare location effect on the spectral characteristics of the diurnal anisotropy of cosmic ray intensity

    Energy Technology Data Exchange (ETDEWEB)

    Yadava, R S; Kumar, S; Naqvi, T N [Aligarh Muslim Univ. (India)

    1977-01-01

    The spectral parameters of the diurnal anisotropy of cosmic ray intensity are studied separately for days where the solar flares have occurred on the western limb as well as on the eastern limb of the solar disc for both nucleonic as well as mesonic components of the cosmic rays. It is observed that the diurnal amplitude of the cosmic ray intensity in space is larger for days where solar flares have occurred on the western limb of the solar disc as compared to the days where solar flares have occurred on the eartern limb of the solar disc. This is true in both nucleonic as well as mesonic components of the cosmic ray intensity. The average value of the direction in space of diurnal anisotropy in local asymptotic time for various stations is almost same and is observed at around the same hours for flares which occur on the western as well as eastern limb of the solar disc. When these results are compared with the direction of the diurnal anisotropy in space on quiet days, it is found that the direction of the diurnal anisotropy on days where solar flares have occurred on the western limb as well as eastern limb of the solar disc is earlier in comparison to quiet days. This phase shift towards earlier hours is about three hours for nucleonic as well as mesonic components of the cosmic rays intensity. The variation of the rigidity exponent observed on different types of days for the nucleonic component has also been discussed.

  3. Improving accuracy and capabilities of X-ray fluorescence method using intensity ratios

    Energy Technology Data Exchange (ETDEWEB)

    Garmay, Andrey V., E-mail: andrew-garmay@yandex.ru; Oskolok, Kirill V.

    2017-04-15

    An X-ray fluorescence analysis algorithm is proposed which is based on a use of ratios of X-ray fluorescence lines intensities. Such an analytical signal is more stable and leads to improved accuracy. Novel calibration equations are proposed which are suitable for analysis in a broad range of matrix compositions. To apply the algorithm to analysis of samples containing significant amount of undetectable elements a use of a dependence of a Rayleigh-to-Compton intensity ratio on a total content of these elements is suggested. The technique's validity is shown by analysis of standard steel samples, model metal oxides mixture and iron ore samples.

  4. A beam intensity monitor for the evaluation beamline for soft x-ray optical elements

    International Nuclear Information System (INIS)

    Imazono, Takashi; Moriya, Naoji; Harada, Yoshihisa; Sano, Kazuo; Koike, Masato

    2012-01-01

    Evaluation Beamline for Soft X-Ray Optical Elements (BL-11) at the SR Center of Ritsumeikan University has been operated to measure the wavelength and angular characteristics of soft x-ray optical components in a wavelength range of 0.65-25 nm using a reflecto-diffractometer (RD). The beam intensity monitor that has been equipped in BL-11 has observed the signal of the zero-th order light. For the purpose of more accurate evaluation of the performance of optical components, a new beam intensity monitor to measure the intensity of the first order light from the monochromator in BL-11 has been developed and installed in just front of RD. The strong positive correlation between the signal of the beam monitor and a detector equipped in the RD is shown. It is successful that the beam intensity of the first order light can be monitored in real time.

  5. Valence electronic structure of Ni in Ni Si alloys from relative K X-ray intensity studies

    Science.gov (United States)

    Kalayci, Y.; Aydinuraz, A.; Tugluoglu, B.; Mutlu, R. H.

    2007-02-01

    The Kβ-to-Kα X-ray intensity ratio of Ni in Ni 3Si, Ni 2Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni 2Si and then increases from Ni 2Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal alloys.

  6. Experimental study of soft X-ray intensity with different anode tips in ...

    Indian Academy of Sciences (India)

    2016-06-15

    Jun 15, 2016 ... c Indian Academy of Sciences. DOI 10.1007/s12043-016-1224-8. Experimental study of soft X-ray intensity with different anode tips in Amirkabir plasma focus device. MORTEZA HABIBI. ∗ and MAHSA MAHTAB. Energy Engineering and Physics Department, Amirkabir University of Technology, Tehran, Iran.

  7. Pionic X-ray intensities from C, CH2 and CD2

    International Nuclear Information System (INIS)

    Daniel, H.; Seki, R.

    1980-01-01

    The relative intensities of the carbon Lsub(α) and Lsub(β) pionic X-ray lines from graphite, polyethylene, and deuterated polyethylene have been measured. No differences between CH 2 and CD 2 were observed, but differences were found between graphite and the two polyethylene targets. (orig.)

  8. Optimisation of intense X-ray sources of Z-pinch type connected to the high intensity current generator SPHINX

    International Nuclear Information System (INIS)

    Calamy, H.; Lassalle, F.; Grunenwald, J.; Zucchini, F.

    2010-01-01

    A new source of intense X-rays in the spectral range of the keV has been designed in the CEA facilities at Gramat (France). This Z-pinch source is based on the implosion of a cylinder of matter that has been ionized by the Lorentz force generated by the injection in the cylinder of an intense current pulse delivered by a HPP (High Pulsed Powers) generator named SPHINX. The cylinder of matter is made up of a few hundreds of thin metal wires (tungsten or aluminium) whose diameter is less than a few tenths of μm. The SPHINX generator is based on the LTD (Linear Transformer Driver) technology. SPHINX stores an energy of 2.2 MJ and delivers a current of 8 MA over a time of 1 μs. SPHINX does not use any technology of time compression, it is a robust, compact machine with reduced maintenance but the price to pay for this simplification is to maintain a high axial homogeneity of the implosion during the initiation phase, it means the pulse time of 1μs. The preliminary experiments that have been performed give the following results: -) for a tungsten cylinder (X ray 1 keV): 28 kJ, 0.6 TW and 25 ns

  9. Mapping the continuous reciprocal space intensity distribution of X-ray serial crystallography.

    Science.gov (United States)

    Yefanov, Oleksandr; Gati, Cornelius; Bourenkov, Gleb; Kirian, Richard A; White, Thomas A; Spence, John C H; Chapman, Henry N; Barty, Anton

    2014-07-17

    Serial crystallography using X-ray free-electron lasers enables the collection of tens of thousands of measurements from an equal number of individual crystals, each of which can be smaller than 1 µm in size. This manuscript describes an alternative way of handling diffraction data recorded by serial femtosecond crystallography, by mapping the diffracted intensities into three-dimensional reciprocal space rather than integrating each image in two dimensions as in the classical approach. We call this procedure 'three-dimensional merging'. This procedure retains information about asymmetry in Bragg peaks and diffracted intensities between Bragg spots. This intensity distribution can be used to extract reflection intensities for structure determination and opens up novel avenues for post-refinement, while observed intensity between Bragg peaks and peak asymmetry are of potential use in novel direct phasing strategies.

  10. On the continuous measurement of the cosmic-ray intensity, 2

    International Nuclear Information System (INIS)

    Ishida, Yoshio; Kanno, Tsunekichi

    1974-01-01

    Since November 1971, the cosmic ray neutron intensity has been measured continuously with 3NM-64 neutron monitor at Fukushima University (140 0 29'E geographic longitude, 37 0 45'N geographic latitude, 27.6 0 N geomagnetic latitude and 10.55 GV cut-off rigidity). After the neutron monitor had been operated during the period of fourteen months at the ground floor of 3-storied ferro-reinforced concrete building, it was removed to the prefabricated house near the old position of the monitor at January 1973. As a result of the removement of the monitor, the expected values for the counting rate and barometric coefficient of our neutron monitor were obtained, 7.5x10 4 cph and -0.64% mb respectively. The monitor was moved out into a new place, the statistical accuracy of counting rate is altered from 0.44% (hourly counting rate) to 0.36%. It can be considered that there is no effect of concrete building near the monitor, for reason that the zenith angle is opened more than 60 0 over the monitor. The difference between the new and the old measurement - measurement environments, intensities, barometric coefficient and others - were discussed. The continuous measurement of the cosmic ray neutron intensity at Fukushima will be kept on beaten track, and the obtained data of the cosmic ray neutron intensity (uncorrected, corrected intensity and barometric pressure) will be sent to WDC-C2 in form of monthly tables. (author)

  11. High-intensity, subkolovolt x-ray calibration facility using a Cockroft--Walton proton accelerator

    International Nuclear Information System (INIS)

    Kuckuck, R.W.; Gaines, J.L.; Ernst, R.D.

    1976-01-01

    Considerable need has arisen for the development of well-calibrated x-ray detectors capable of detecting photons with energies between 100 and 1000 electron-volts. This energy region is of significant interest since the x-ray emission from high-temperature (kT approximately 1.0 keV), laser-produced plasmas is predominantly in this range. A high-intensity, subkilovolt x-ray calibration source was developed which utilizes proton-induced inner-shell atomic fluorescence of low-Z elements. The high photon yields and low bremsstrahlung background associated with this phenomenon are ideally suited to provide an intense, nearly monoenergetic x-ray calibration source for detector development applications. The proton accelerator is a 3 mA, 300 kV Cockroft-Walton using a conventional rf hydrogen ion source. Seven remotely-selectable liquid-cooled targets capable of heat dissipation of 5 kW/cm 2 are used to provide characteristic x-rays with energies between 100 and 1000 eV. Source strengths are of the order of 10 13 to 10 14 photons/sec. A description of the facility is presented. Typical x-ray spectra (B-K, C-K, Ti-L, Fe-L and Cu-L) and flux values will be shown. Problems such as spectral contamination due to carbon buildup on the target and to backscattered particles are discussed

  12. Impact of intense x-ray pulses on a NaI(Tl)-based gamma camera

    Science.gov (United States)

    Koppert, W. J. C.; van der Velden, S.; Steenbergen, J. H. L.; de Jong, H. W. A. M.

    2018-03-01

    In SPECT/CT systems x-ray and γ-ray imaging is performed sequentially. Simultaneous acquisition may have advantages, for instance in interventional settings. However, this may expose a gamma camera to relatively high x-ray doses and deteriorate its functioning. We studied the NaI(Tl) response to x-ray pulses with a photodiode, PMT and gamma camera, respectively. First, we exposed a NaI(Tl)-photodiode assembly to x-ray pulses to investigate potential crystal afterglow. Next, we exposed a NaI(Tl)-PMT assembly to 10 ms LED pulses (mimicking x-ray pulses) and measured the response to flashing LED probe-pulses (mimicking γ-pulses). We then exposed the assembly to x-ray pulses, with detector entrance doses of up to 9 nGy/pulse, and analysed the response for γ-pulse variations. Finally, we studied the response of a Siemens Diacam gamma camera to γ-rays while exposed to x-ray pulses. X-ray exposure of the crystal, read out with a photodiode, revealed 15% afterglow fraction after 3 ms. The NaI(Tl)-PMT assembly showed disturbances up to 10 ms after 10 ms LED exposure. After x-ray exposure however, responses showed elevated baselines, with 60 ms decay-time. Both for x-ray and LED exposure and after baseline subtraction, probe-pulse analysis revealed disturbed pulse height measurements shortly after exposure. X-ray exposure of the Diacam corroborated the elementary experiments. Up to 50 ms after an x-ray pulse, no events are registered, followed by apparent energy elevations up to 100 ms after exposure. Limiting the dose to 0.02 nGy/pulse prevents detrimental effects. Conventional gamma cameras exhibit substantial dead-time and mis-registration of photon energies up to 100 ms after intense x-ray pulses. This is due PMT limitations and due to afterglow in the crystal. Using PMTs with modified circuitry, we show that deteriorative afterglow effects can be reduced without noticeable effects on the PMT performance, up to x-ray pulse doses of 1 nGy.

  13. Estimation of signal intensity for online measurement X-ray pinhole camera

    International Nuclear Information System (INIS)

    Dong Jianjun; Liu Shenye; Yang Guohong; Yu Yanning

    2009-01-01

    The signal intensity was estimated for on-line measurement X-ray pinhole camera with CCD as measurement equipment. The X-ray signal intensity counts after the attenuation of thickness-varied Be filters and different material flat mirrors respectively were estimated using the energy spectrum of certain laser prototype and the quantum efficiency curve of PI-SX1300 CCD camera. The calculated results indicate that Be filters no thicker than 200 μm can only reduce signal intensity by one order of magnitude, and so can Au flat mirror with 3 degree incident angle, Ni, C and Si flat mirrors with 5 degree incident angle,but the signal intensity counts for both attenuation methods are beyond the saturation counts of the CCD camera. We also calculated the attenuation of signal intensity for different thickness Be filters combined with flat mirrors, indicates that the combination of Be filters with the thickness between 20 and 40 μm and Au flat mirror with 3 degree incident angle or Ni flat mirror with 5 degree incident angle is a good choice for the attenuation of signal intensity. (authors)

  14. Cosmic ray intensity distribution in the vertical direction to solar equator plane

    International Nuclear Information System (INIS)

    Nosaka, Toru; Mori, Satoru; Sagisaka, Shuji.

    1983-01-01

    The data of the annual variation of cosmic ray intensity measured by neutron detectors were used to study the distribution of cosmic ray intensity vertical to the solar equator plane and its long term variation. The data used were obtained at Deep River, Kiel, Kerguelen Island, McMurdo, Ottawa, and Mt. Washington. All data showed annual variation. The patterns and degree of variation obtained in northern and southern hemisphere were similar. The summation dial representation of the annual variation and semi-annual variation of cosmic ray was obtained. The inversion of annual variation in 1958 - 1959 and 1968 - 1969 corresponded to the inversion of polarity of solar pole magnetic field. The semi-annual variation showed a complex behavior. The helio-latitudial distribution of cosmic ray intensity was obtained. The asymmetric distribution in relation to the solar equator was observed in the annual variation. The northward gradient of density in 1955 - 1958 and southward gradient in 1959 - 1968 were seen. (Kato, T.)

  15. Update of regional intensity-duration-frequency curves in Denmark: Tendency towards increased storm intensities

    DEFF Research Database (Denmark)

    Madsen, H.; Arnbjerg-Nielsen, Karsten; Mikkelsen, Peter Steen

    2009-01-01

    The regional model for estimation of extreme rainfall characteristics in Denmark has been updated with data from the augmented rain database 1 January 1997-1 August 2005, corresponding to almost twice the amount of data used in the previous study (1 January 1979-1 January 1997). In general...... patterns and a sub-regional division of the country in a western and eastern part. Comparison with the previous regional analysis shows a general increase in extreme rainfall characteristics. For the durations (30 min-3 h) and return periods (similar to 10 years) typical for most urban drainage designs...

  16. An experimental measurement of metal multilayer x-ray reflectivity degradation due to intense x-ray flux

    International Nuclear Information System (INIS)

    Hockaday, M.Y.P.

    1987-06-01

    The degradation of the x-ray reflection characteristics of metal multilayer Bragg diffractors due to intense x-ray flux was investigated. The Z-pinch plasma produced by PROTO II of Sandia National Laboratories, Albuquerque, New Mexico, was used as the source. The plasma generated total x-ray yields of as much as 40 kJ with up to 15 kJ in the neon hydrogen- and helium-like resonance lines in nominal 20-ns pulses. Molybdenum-carbon, palladium-carbon, and tungsten-carbon metal multilayers were placed at 15 and 150 cm from the plasma center. The multilayers were at nominal angles of 5 0 and 10 0 to diffract the neon resonance lines. The time-integrated x-ray reflection of the metal multilayers was monitored by x-ray film. A fluorescer-fiber optic-visible streak camera detector system was then used to monitor the time-resolved x-ray reflection characteristics of 135 A- 2d tungsten-carbon multilayers. A large specular component in the reflectivity prevented determination of the rocking curve of the multilayer. For a neon implosion onto a vanadium-doped polyacrylic acid foam target shot, detailed modeling was attempted. The spectral flux was determined with data from 5 XRD channels and deconvolved using the code SHAZAM. The observed decay in reflectivity was assumed to correspond to the melting of the first tungsten layer. A ''conduction factor'' of 82 was required to manipulate the heat loading of the first tungsten layer such that the time of melting corresponded to the observed decay. The power at destruction was 141 MW/cm 2 and the integrated energy at destruction was 2.0 J/cm 2 . 82 refs., 66 figs., 10 tabs

  17. Origin-independent calculation of quadrupole intensities in X-ray spectroscopy

    International Nuclear Information System (INIS)

    Bernadotte, Stephan; Atkins, Andrew J.; Jacob, Christoph R.

    2012-01-01

    For electronic excitations in the ultraviolet and visible range of the electromagnetic spectrum, the intensities are usually calculated within the dipole approximation, which assumes that the oscillating electric field is constant over the length scale of the transition. For the short wavelengths used in hard X-ray spectroscopy, the dipole approximation may not be adequate. In particular, for metal K-edge X-ray absorption spectroscopy (XAS), it becomes necessary to include higher-order contributions. In quantum-chemical approaches to X-ray spectroscopy, these so-called quadrupole intensities have so far been calculated by including contributions depending on the square of the electric-quadrupole and magnetic-dipole transition moments. However, the resulting quadrupole intensities depend on the choice of the origin of the coordinate system. Here, we show that for obtaining an origin-independent theory, one has to include all contributions that are of the same order in the wave vector consistently. This leads to two additional contributions depending on products of the electric-dipole and electric-octupole and of the electric-dipole and magnetic-quadrupole transition moments, respectively. We have implemented such an origin-independent calculation of quadrupole intensities in XAS within time-dependent density-functional theory, and demonstrate its usefulness for the calculation of metal and ligand K-edge XAS spectra of transition metal complexes.

  18. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ˜95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ˜6.0%.

  19. Wearable device for monitoring momentary presence of intense x-ray and/or ultra-violet radiations

    International Nuclear Information System (INIS)

    Shriner, W.

    1981-01-01

    A credit-card-size clear-plastic-encased device can be worn or carried by a person to warn him of the momentary presence of dangerous intensities of ultra-violet and/or x-ray radiations. A base lamina (e.g. of cardboard) is coated with a material (e.g. zinc-cadmium sulfide or lead-barium sulfate) which fluoresces under such radiations. Numerals, letters, words or symbols are printed over the fluorescent coat with a material inhibitory to said radiations so that a warning message in dark print will appear on a light background when dangerous intensities of said radiations are present. An x-ray-warning area is covered with an ultra-violet absorbing screen so that said area will glow only under x-rays (Which rays will also activate the remaining ultra-violet-responsive area). The colors of the laminas and the coats are so selected that the messages are not visible when dangerous radiations are not present. If desired, only the message can be printed with fluorescent material so as to glow on a darker background. Optionally, step-layer attenuation devices can be added to indicate degrees of radiation; and reflecting surfaces can underlie the fluorescent coat to increase efficiency and/or sensitively

  20. The design of a measuring system for soft X ray absolute intensity

    International Nuclear Information System (INIS)

    Cui Congwu; Cui Mingqi

    1997-01-01

    The design of a measuring system for soft X ray absolute intensity in detail is presented. The system consists of two parts: the ionization chamber, the silicon photodiode and its transferring system. The system can be used as the primary standard detector for the measurement of soft X ray absolute radiation flux in the energy range of 50 to 2000 eV after being calibrated. The whole system will be installed to the newly built beamline of 3W1B at Beijing Synchrotron Radiation Facility

  1. Researching design solutions for frames of buildings in case of increased seismic intensity in specific zones

    OpenAIRE

    Panasyuk Leonid; Kravchenko Galina; Trufanova Elena

    2017-01-01

    Currently, there is a trend to increase the estimated seismic hazard for construction sites. With this, the buildings erected under the previously valid norms have the lesser hazard resistance. The present article inquiries into an issue of how the design solutions affect the safety of the building change under the increased seismic intensity. This article represents the calculation of a building without regard to seismic intensity and the same was made for a rate-7 seismic intensity district...

  2. Momentum and zenithal dependence of the enhancements of intensities of cosmic ray muons

    International Nuclear Information System (INIS)

    Abdel-Monem, M.S.; Osborne, A.R.; Benbrook, J.R.; Sheldon, W.R.; Duller, N.M.; Green, P.J.; Choate, L.M.; Magnusson, C.E.

    1977-01-01

    The absolute directional differential intensities of high-energy cosmic ray muons near sea level have been measured over the momentum range 2-700 GeV/c in the vertical direction and zenithal interval 55deg-90deg. The measurements were made with the AMH magnetic spectrometer-telescope. The enhancements I(65deg)/I(0deg) and I(80deg)/I(0deg) of the muon intensities as a function of momentum are presented and compared with the theoretical results of Maeda and Asbury et al. (author)

  3. Compression of Semesters or Intensity of Study: What is it that Increases Student Success?

    Science.gov (United States)

    Spurling, Steven

    This study examined the relationship between intensity of study (defined as more hours per week of class within a subject matter area) and student success. The researcher identified two possible methods for increasing the intensity of study: (1) Compression Hypothesis--shortening the length of terms and increasing the amount of time per week spent…

  4. An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

    International Nuclear Information System (INIS)

    Polee, C; Chankow, N; Srisatit, S; Thong-Aram, D

    2015-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking information of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a small detector. Application software was developed for Android mobile phone to remotely control the device and to display counting data via Bluetooth communication. Prior to film exposure, the device is placed behind a specimen to measure transmitted intensity which is inversely proportional to the exposure. Unlike in using the conventional exposure curve, correction factors for source decay, source-to- film distance, specimen thickness and kind of material are not needed. The developed technique and device make radiographic process economic, convenient and more reliable. (paper)

  5. An Industrial Radipgraphy Exposure Device Based on Measurement of Transmitted Gamma-Ray Intensity

    International Nuclear Information System (INIS)

    Polee, C.; Chankow, N.; Srisatit, S.; Thong-Aram, D.

    2014-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking knowledge of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a D3372 Hamamatsu small GM tube. Application software is developed for Android mobile phone to remotely control the device and to display the counting data via Bluetooth. Prior to placing film, the device is placed behind the specimen to be radiographed to determine the exposure time from the transmitted intensity which is independent on source activity, source-to-film distance, specimen thickness and kind of material. The developed technique and device make radiographic process economic, convenient and more reliable.

  6. Asymmetrically cut crystal pair as x-ray magnifier for imaging at high intensity laser facilities

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, C. I.; Feldman, U. [Artep Inc., 2922 Excelsior Spring Circle, Ellicott City, Maryland 21042 (United States); Seely, J. F. [Space Science Division, Naval Research Laboratory, Washington, DC 20375-5352 (United States); Curry, J. J.; Hudson, L. T.; Henins, A. [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    2010-10-15

    The potential of an x-ray magnifier prepared from a pair of asymmetrically cut crystals is studied to explore high energy x-ray imaging capabilities at high intensity laser facilities. OMEGA-EP and NIF when irradiating mid and high Z targets can be a source of high-energy x-rays whose production mechanisms and use as backlighters are a subject of active research. This paper studies the properties and potential of existing asymmetric cut crystal pairs from the National Institute of Standards and Technology (NIST) built in a new enclosure for imaging x-ray sources. The technique of the x-ray magnifier has been described previously. This new approach is aimed to find a design that could be used at laser facilities by magnifying the x-ray source into a screen far away from the target chamber center, with fixed magnification defined by the crystals' lattice spacing and the asymmetry angles. The magnified image is monochromatic and the imaging wavelength is set by crystal asymmetry and incidence angles. First laboratory results are presented and discussed.

  7. Results of a search for paraphotons with intense X-ray beams at SPring-8

    International Nuclear Information System (INIS)

    Inada, T.; Namba, T.; Asai, S.; Kobayashi, T.; Tanaka, Y.; Tamasaku, K.; Sawada, K.; Ishikawa, T.

    2013-01-01

    A search for paraphotons, or hidden U(1) gauge bosons, is performed using an intense X-ray beamline at SPring-8. “Light Shining through a Wall” technique is used in this search. No excess of events above background is observed. A stringent constraint is obtained on the photon–paraphoton mixing angle, χ −5 (95% C.L.) for 0.04 eV γ ′ <26 keV

  8. Galactic cosmic-ray intensity to a heliocentric distance of 18 AU

    International Nuclear Information System (INIS)

    Van Allen, J.A.

    1980-01-01

    An updated report is given of observations of galactic cosmic-ray intensity to heliocentric radial distance of 8.6 and 18.4 AU with Pioneer 11 and Pioneer 10, respectively. Solar activity via the magnetic structure of the interplanetary medium continues to modulate the intensity out to the greatest distance reached thus far. During the 7 year period 1972 March to 1979 March, the galactic cosmic-ray intensity E/sub p/>80 MeV as measured by detectors on Pioneers 10 and 11 exhibited aperiodic temporal variations by about a factor of 2 and on a time scale of the order of a year and quasi-persistent cyclic variations of 26 day period and amplitude a few percent. The former are attributed to overall changes in the magnetic field structure of the heliosphere, the latter to fast-slow solar wind streams in and near the ecliptic plane and not to toward-away magnetic field sectors. The apparent heliographic latitude dependence of intensity is 0( +- 1.5)% per 10 0 in the latitude range +7 0 .7 to +15. 0 8, though it is possible that radially dependent temporal variations over the large difference in the heliocentric radial distances of the two spacecraft may make this result of limited significance. For protons of energy E/sub p/>80 MeV, there is a fairly consistent heliocentric radial gradient of +2.1( +- 0.3)% per AU integral intensity until 1978 April--May, at which time a substantial disruption of the distribution of cosmic rays in the heliosphere occurred

  9. Disparity in formulations used for fluorescent X-ray intensity measurements

    International Nuclear Information System (INIS)

    Mittal, Raj; Gupta, Sheenu

    2011-01-01

    The paper presents a problem in computations of X-ray fluorescence cross-sections, shell/sub-shell fluorescence yields, Coster-Kronig yields, vacancy alignment, etc. from X-ray fluorescence (XRF) studies. While using barn/atom as a unit for cross-sections if the atomic masses are not considered it causes a discrepancy in the measured cross-section, yield and alignment values. Most of the earlier publications are being quoted where such an oversight has occurred and discrepancy is evident. - Highlights: → Manuscript gives basic formulation for measurements of fluorescent X-ray intensities. → Most publications ignored the fact that use of barn/atom units for cross-sections requires atomic masses. → Published experimental results higher by a factor ≥2 or less by factor 1/M K . → Inspection of published data on XRF parameters needed.

  10. Investigation of L X-ray intensity ratios in Pt induced by proton collisions

    International Nuclear Information System (INIS)

    Kaur, Manpuneet; Kaur, Mandeep; Mohan, Harsh; Jain, Arvind Kumar; Singh, Parjit S.; Vohra, Neelam; Sharma, Sunita

    2015-01-01

    A survey of literature on L X-ray parameters inspires us for taking up the present investigation. These parameters are useful to study atomic properties. In view of this, we report L X-ray intensity ratios for Pt, namely, L ℓ / L α , L β / L α and L γ / L α with proton collisions over the energy range 260 - 400 keV with an interval of 20 keV. The intention of research presented in this paper is to explore their energy dependence and comparison with theoretical calculations. These analyses will yield a data in the low energy region which assist in better clarity of proton induced X-ray emission phenomenon

  11. Spectroscopic study of site selective DNA damage induced by intense soft X-rays

    CERN Document Server

    Fujii, K

    2003-01-01

    To investigate the mechanisms of DNA damage induced by direct photon impact, we observed the near edge X-ray absorption fine structures (NEXAFS) of DNA nucleobases using monochromatic synchrotron soft X-rays around nitrogen and oxygen K-shell excitation regions. Each spectrum obtained has unique structure corresponding to pi* excitation of oxygen or nitrogen 1s electron. These aspects open a way of nucleobase-selective photo-excitation in a DNA molecule using high resolution monochromatized soft X-rays. From the analysis of polarization-dependent intensities of the pi* resonance peak, it is clarified that adenine, guanine an uracil form orientated surface structure. Furthermore from the direct measurement of positive ions desorbed from photon irradiated DNA components, it is revealed that the sugar moiety is a fragile site in a DNA molecule. (author)

  12. Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, P. [Department of Science Education, Faculty of Education, Erzincan University, 24030 Erzincan (Turkey)], E-mail: pasayalcin@hotmail.com; Porikli, S.; Kurucu, Y.; Sahin, Y. [Department of Physics, Faculty of Sciences, Atatuerk University, 25240 Erzurum (Turkey)

    2008-05-22

    The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

  13. Modeling of finite systems irradiated by intense ultrashort hard X-ray pulses

    Energy Technology Data Exchange (ETDEWEB)

    Jurek, Zoltan [Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Ziaja, Beata [Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Santra, Robin [Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Department of Physics, University of Hamburg, Jungiusstrasse 9, 20355 Hamburg (Germany)

    2013-07-01

    Large number of experiments have already been carried out at the existing hard X-Ray Free-Electron Laser facilities (LCLS, SACLA) during the recent years. Their great success generates even higher anticipation for the forthcoming X-ray sources (European XFEL). Single molecule imaging and nanoplasma formation are the challenging projects with XFELs that investigate the interaction of finite, small objects, e.g. single molecules, atomic clusters with intense X-ray radiation. Accurate modelling of the time evolution of such irradiated systems is required in order to understand the current experiments and to inspire new directions of experimental investigation. In this presentation we report on our theoretical molecular-dynamics tool able to follow non-equilibrium dynamics within finite systems irradiated by intense X-ray pulses. We introduce the relevant physical processes, present computational methods used, discuss their limitations and also the specific constraints on calculations imposed by experimental conditions. Finally, we conclude with a few simulation examples.

  14. Fast voxel and polygon ray-tracing algorithms in intensity modulated radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Fox, Christopher; Romeijn, H. Edwin; Dempsey, James F.

    2006-01-01

    We present work on combining three algorithms to improve ray-tracing efficiency in radiation therapy dose computation. The three algorithms include: An improved point-in-polygon algorithm, incremental voxel ray tracing algorithm, and stereographic projection of beamlets for voxel truncation. The point-in-polygon and incremental voxel ray-tracing algorithms have been used in computer graphics and nuclear medicine applications while the stereographic projection algorithm was developed by our group. These algorithms demonstrate significant improvements over the current standard algorithms in peer reviewed literature, i.e., the polygon and voxel ray-tracing algorithms of Siddon for voxel classification (point-in-polygon testing) and dose computation, respectively, and radius testing for voxel truncation. The presented polygon ray-tracing technique was tested on 10 intensity modulated radiation therapy (IMRT) treatment planning cases that required the classification of between 0.58 and 2.0 million voxels on a 2.5 mm isotropic dose grid into 1-4 targets and 5-14 structures represented as extruded polygons (a.k.a. Siddon prisms). Incremental voxel ray tracing and voxel truncation employing virtual stereographic projection was tested on the same IMRT treatment planning cases where voxel dose was required for 230-2400 beamlets using a finite-size pencil-beam algorithm. Between a 100 and 360 fold cpu time improvement over Siddon's method was observed for the polygon ray-tracing algorithm to perform classification of voxels for target and structure membership. Between a 2.6 and 3.1 fold reduction in cpu time over current algorithms was found for the implementation of incremental ray tracing. Additionally, voxel truncation via stereographic projection was observed to be 11-25 times faster than the radial-testing beamlet extent approach and was further improved 1.7-2.0 fold through point-classification using the method of translation over the cross product technique

  15. X-ray intensity and source size characterizations for the 25 kV upgraded Manson source at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Loisel, G., E-mail: gploise@sandia.gov; Lake, P.; Gard, P.; Dunham, G.; Nielsen-Weber, L.; Wu, M. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Norris, E. [Missouri University of Science and Technology, Rolla, Missouri 65409 (United States)

    2016-11-15

    At Sandia National Laboratories, the x-ray generator Manson source model 5 was upgraded from 10 to 25 kV. The purpose of the upgrade is to drive higher characteristics photon energies with higher throughput. In this work we present characterization studies for the source size and the x-ray intensity when varying the source voltage for a series of K-, L-, and M-shell lines emitted from Al, Y, and Au elements composing the anode. We used a 2-pinhole camera to measure the source size and an energy dispersive detector to monitor the spectral content and intensity of the x-ray source. As the voltage increases, the source size is significantly reduced and line intensity is increased for the three materials. We can take advantage of the smaller source size and higher source throughput to effectively calibrate the suite of Z Pulsed Power Facility crystal spectrometers.

  16. X-ray intensity and source size characterizations for the 25 kV upgraded Manson source at Sandia National Laboratories.

    Science.gov (United States)

    Loisel, G; Lake, P; Gard, P; Dunham, G; Nielsen-Weber, L; Wu, M; Norris, E

    2016-11-01

    At Sandia National Laboratories, the x-ray generator Manson source model 5 was upgraded from 10 to 25 kV. The purpose of the upgrade is to drive higher characteristics photon energies with higher throughput. In this work we present characterization studies for the source size and the x-ray intensity when varying the source voltage for a series of K-, L-, and M-shell lines emitted from Al, Y, and Au elements composing the anode. We used a 2-pinhole camera to measure the source size and an energy dispersive detector to monitor the spectral content and intensity of the x-ray source. As the voltage increases, the source size is significantly reduced and line intensity is increased for the three materials. We can take advantage of the smaller source size and higher source throughput to effectively calibrate the suite of Z Pulsed Power Facility crystal spectrometers.

  17. Development of a software for reconstruction of X-ray fluorescence intensity maps

    International Nuclear Information System (INIS)

    Almeida, Andre Pereira de; Braz, Delson; Mota, Carla Lemos; Oliveira, Luis Fernando de; Barroso, Regina Cely; Pinto, Nivia Graciele Villela; Cardoso, Simone Coutinho; Moreira, Silvana

    2009-01-01

    The technique of X-ray fluorescence (XRF) using SR microbeams is a powerful analysis tool for studying elemental composition in several samples. One application of this technique is the analysis done through the mapping of chemical elements forming a matrix of data. The aim of this work is the presentation of the program MapXRF, an in-house software designed to optimize the processing and mapping of fluorescence intensities data. This program uses spectra generated by QXAS as input data and separates the intensities of each chemical element found in the fluorescence spectra in files themselves. From these files, the program generates the intensity maps that can be visualized in any program of treatment of images. The proposed software was tested using fluorescence data obtained in the XRF beamline of XRF at Synchrotron Light National Laboratory (LNLS), Brazil. Automatic 2D scans were performed and element distribution maps were obtained in the form of a matrix of data. (author)

  18. Development of a software for reconstruction of X-ray fluorescence intensity maps

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Andre Pereira de; Braz, Delson; Mota, Carla Lemos, E-mail: apalmeid@gmail.co, E-mail: delson@lin.ufrj.b, E-mail: clemos@con.ufrj.b [Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Oliveira, Luis Fernando de; Barroso, Regina Cely; Pinto, Nivia Graciele Villela, E-mail: cely@uerj.b, E-mail: lfolive@uerj.b, E-mail: nitatag@gmail.co [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica; Cardoso, Simone Coutinho, E-mail: simone@if.ufrj.b [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Fisica; Moreira, Silvana, E-mail: silvana@fec.unicamp.b [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo

    2009-07-01

    The technique of X-ray fluorescence (XRF) using SR microbeams is a powerful analysis tool for studying elemental composition in several samples. One application of this technique is the analysis done through the mapping of chemical elements forming a matrix of data. The aim of this work is the presentation of the program MapXRF, an in-house software designed to optimize the processing and mapping of fluorescence intensities data. This program uses spectra generated by QXAS as input data and separates the intensities of each chemical element found in the fluorescence spectra in files themselves. From these files, the program generates the intensity maps that can be visualized in any program of treatment of images. The proposed software was tested using fluorescence data obtained in the XRF beamline of XRF at Synchrotron Light National Laboratory (LNLS), Brazil. Automatic 2D scans were performed and element distribution maps were obtained in the form of a matrix of data. (author)

  19. Time dependence of X-ray polarizability of a crystal induced by an intense femtosecond X-ray pulse

    Directory of Open Access Journals (Sweden)

    A. Leonov

    2014-11-01

    Full Text Available The time evolution of the electron density and the resulting time dependence of Fourier components of the X-ray polarizability of a crystal irradiated by highly intense femtosecond pulses of an X-ray free-electron laser (XFEL is investigated theoretically on the basis of rate equations for bound electrons and the Boltzmann equation for the kinetics of the unbound electron gas. The photoionization, Auger process, electron-impact ionization, electron–electron scattering and three-body recombination have been implemented in the system of rate equations. An algorithm for the numerical solution of the rate equations was simplified by incorporating analytical expressions for the cross sections of all the electron configurations in ions within the framework of the effective charge model. Using this approach, the time dependence of the inner shell populations during the time of XFEL pulse propagation through the crystal was evaluated for photon energies between 4 and 12 keV and a pulse width of 40 fs considering a flux of 1012 photons pulse−1 (focusing on a spot size of ∼1 µm. This flux corresponds to a fluence ranging between 0.8 and 2.4 mJ µm−2. The time evolution of the X-ray polarizability caused by the change of the atomic scattering factor during the pulse propagation is numerically analyzed for the case of a silicon crystal. The time-integrated polarizability drops dramatically if the fluence of the X-ray pulse exceeds 1.6 mJ µm−2.

  20. Neonatal doses from X ray examinations by birth weight in a neonatal intensive care unit

    Energy Technology Data Exchange (ETDEWEB)

    Ono, K.; Akahane, K.; Aota, T.; Hada, M.; Takano, Y.; Kai, M.; Kusama, T

    2003-07-01

    The aim of this study was to investigate the frequency and type of X ray examinations performed on neonates classified according to their birth weight in a neonatal intensive care unit (NICU). In this study, the radiology records of 2408 neonates who were admitted to the NICU of Oita Prefectural Hospital between January 1994 and September 1999 were investigated. This study revealed that the neonates with earlier gestational ages and lower birth weights required longer NICU stays and more frequent X ray examinations made using a mobile X ray unit. The average number of X ray examinations performed on neonates of less than 750 g birth weight was 26 films per neonate. In regard to computed tomography and fluoroscopy, no significant relationship was found between the birth weight and number of X rays. This study revealed that the entrance-surface dose per neonate was dependent upon the birth weight, while the maximum dose was not dependent upon the birth weight. The average neonatal dose in the NICU was predominantly from computed tomography and fluoroscopy. The individual dose varied widely among neonates. (author)

  1. Neonatal doses from X ray examinations by birth weight in a neonatal intensive care unit

    International Nuclear Information System (INIS)

    Ono, K.; Akahane, K.; Aota, T.; Hada, M.; Takano, Y.; Kai, M.; Kusama, T.

    2003-01-01

    The aim of this study was to investigate the frequency and type of X ray examinations performed on neonates classified according to their birth weight in a neonatal intensive care unit (NICU). In this study, the radiology records of 2408 neonates who were admitted to the NICU of Oita Prefectural Hospital between January 1994 and September 1999 were investigated. This study revealed that the neonates with earlier gestational ages and lower birth weights required longer NICU stays and more frequent X ray examinations made using a mobile X ray unit. The average number of X ray examinations performed on neonates of less than 750 g birth weight was 26 films per neonate. In regard to computed tomography and fluoroscopy, no significant relationship was found between the birth weight and number of X rays. This study revealed that the entrance-surface dose per neonate was dependent upon the birth weight, while the maximum dose was not dependent upon the birth weight. The average neonatal dose in the NICU was predominantly from computed tomography and fluoroscopy. The individual dose varied widely among neonates. (author)

  2. Local Times of Galactic Cosmic Ray Intensity Maximum and Minimum in the Diurnal Variation

    Directory of Open Access Journals (Sweden)

    Su Yeon Oh

    2006-06-01

    Full Text Available The Diurnal variation of galactic cosmic ray (GCR flux intensity observed by the ground Neutron Monitor (NM shows a sinusoidal pattern with the amplitude of 1sim 2 % of daily mean. We carried out a statistical study on tendencies of the local times of GCR intensity daily maximum and minimum. To test the influences of the solar activity and the location (cut-off rigidity on the distribution in the local times of maximum and minimum GCR intensity, we have examined the data of 1996 (solar minimum and 2000 (solar maximum at the low-latitude Haleakala (latitude: 20.72 N, cut-off rigidity: 12.91 GeV and the high-latitude Oulu (latitude: 65.05 N, cut-off rigidity: 0.81 GeV NM stations. The most frequent local times of the GCR intensity daily maximum and minimum come later about 2sim3 hours in the solar activity maximum year 2000 than in the solar activity minimum year 1996. Oulu NM station whose cut-off rigidity is smaller has the most frequent local times of the GCR intensity maximum and minimum later by 2sim3 hours from those of Haleakala station. This feature is more evident at the solar maximum. The phase of the daily variation in GCR is dependent upon the interplanetary magnetic field varying with the solar activity and the cut-off rigidity varying with the geographic latitude.

  3. 2-D Modelling of Long Period Variations of Galactic Cosmic Ray Intensity

    International Nuclear Information System (INIS)

    Siluszyk, M; Iskra, K; Alania, M

    2015-01-01

    A new two-dimensional (2-D) time dependent model describing long-period variations of the Galactic Cosmic Ray (GCR) intensity has been developed. New approximations for the changes of the magnitude B of the Interplanetary Magnetic Field (IMF), the tilt angle δ of the Heliospheric Neutral Sheet (HNS) and drift effects of the GCR particles have been included into the model. Moreover, temporal changes of the exponent γ expressing the power law - rigidity dependence of the amplitudes of the 11-year variation of the GCR intensity have been added. We show that changes of the expected GCR particle density precedes changes of the GCR intensity measured by the Moscow Neutron (MN) monitor by about 18 months. So ∼18 months can be taken as an effective delay time between the expected intensity caused by the combined influence of the changes of the parameters implemented in the time-dependent 2-D model and the GCR intensity measured by neutron monitors during the 21 cycle of solar activity. (paper)

  4. The effect of increasing exports on industrial energy intensity in China

    International Nuclear Information System (INIS)

    Zheng Yingmei; Qi Jianhong; Chen Xiaoliang

    2011-01-01

    Given China's heavy reliance on fuel energy and the dominance of its industrial sector in the economy, improving energy efficiency remains one of the practical means for the country to decrease energy intensity and to fulfill its commitment made at the Copenhagen Climate Change Conference to achieve a 40-45 percent reduction in CO 2 emission intensity by 2020. This study investigates the impact of exports on industrial energy intensity to explore the possibility of reducing energy intensity through greater exports. A panel varying-coefficient regression model with a dataset of China's 20 industrial sub-sectors over 1999-2007 suggests that in general, greater exports aggravate energy intensity of the industrial sector and that great divergences exist in the impact of exports on energy intensity across sub-sectors. A panel threshold model further estimates the thresholds for the major determinants of energy intensity: exports, input in technological innovations, and Foreign Direct Investment (FDI) intensity. Given the great differences in specific sub-sector characteristics and the changing roles played by different factors across sub-sectors, there is no general export policy that would work for all sub-sectors in reducing sub-sector energy intensity. Instead, policies and measures aiming to encourage more efficient use of energy should take into full consideration the characteristics and situations of individual sub-sectors. - Research highlights: → We examine the impact of exports on industrial energy intensity in China. → Greater exports increase industrial energy intensity as a whole. → Divergences exist in the impact of exports on energy intensity across sub-sectors. → China should discard policies encouraging exports at the cost of energy efficiency. → Export policy to reduce energy intensity should cater to sub-sector characteristics.

  5. The effect of increasing exports on industrial energy intensity in China

    Energy Technology Data Exchange (ETDEWEB)

    Zheng Yingmei [School of Economics, Shandong University, 27 Shanda South Road, Jinan, Shandong Province 250100 (China); Qi Jianhong, E-mail: sducatherine@gmail.co [School of Economics, Shandong University, 27 Shanda South Road, Jinan, Shandong Province 250100 (China); Chen Xiaoliang [School of Economics, Shandong University, 27 Shanda South Road, Jinan, Shandong Province 250100 (China)

    2011-05-15

    Given China's heavy reliance on fuel energy and the dominance of its industrial sector in the economy, improving energy efficiency remains one of the practical means for the country to decrease energy intensity and to fulfill its commitment made at the Copenhagen Climate Change Conference to achieve a 40-45 percent reduction in CO{sub 2} emission intensity by 2020. This study investigates the impact of exports on industrial energy intensity to explore the possibility of reducing energy intensity through greater exports. A panel varying-coefficient regression model with a dataset of China's 20 industrial sub-sectors over 1999-2007 suggests that in general, greater exports aggravate energy intensity of the industrial sector and that great divergences exist in the impact of exports on energy intensity across sub-sectors. A panel threshold model further estimates the thresholds for the major determinants of energy intensity: exports, input in technological innovations, and Foreign Direct Investment (FDI) intensity. Given the great differences in specific sub-sector characteristics and the changing roles played by different factors across sub-sectors, there is no general export policy that would work for all sub-sectors in reducing sub-sector energy intensity. Instead, policies and measures aiming to encourage more efficient use of energy should take into full consideration the characteristics and situations of individual sub-sectors. - Research highlights: {yields} We examine the impact of exports on industrial energy intensity in China. {yields} Greater exports increase industrial energy intensity as a whole. {yields} Divergences exist in the impact of exports on energy intensity across sub-sectors. {yields} China should discard policies encouraging exports at the cost of energy efficiency. {yields} Export policy to reduce energy intensity should cater to sub-sector characteristics.

  6. Neutron beam design for low intensity neutron and gamma-ray radioscopy using small neutron sources

    CERN Document Server

    Matsumoto, T

    2003-01-01

    Two small neutron sources of sup 2 sup 5 sup 2 Cf and sup 2 sup 4 sup 1 Am-Be radioisotopes were used for design of neutron beams applicable to low intensity neutron and gamma ray radioscopy (LINGR). In the design, Monte Carlo code (MCNP) was employed to generate neutron and gamma ray beams suited to LINGR. With a view to variable neutron spectrum and neutron intensity, various arrangements were first examined, and neutron-filter, gamma-ray shield and beam collimator were verified. Monte Carlo calculations indicated that with a suitable filter-shield-collimator arrangement, thermal neutron beam of 3,900 ncm sup - sup 2 s sup - sup 1 with neutron/gamma ratio of 7x10 sup 7 , and 25 ncm sup - sup 2 s sup - sup 1 with very large neutron/gamma ratio, respectively, could be produced by using sup 2 sup 5 sup 2 Cf(122 mu g) and a sup 2 sup 4 sup 1 Am-Be(37GBq)radioisotopes at the irradiation port of 35 cm from the neutron sources.

  7. Numerical modeling of the 22-year variation of the cosmic ray intensity and anisotropy

    International Nuclear Information System (INIS)

    Kadokura, A.; Nishida, A.

    1986-01-01

    We have solved the two-dimensional time-dependent diffusion-convection equation numerically to obtain the distribution and anisotropy of cosmic rays in the heliosphere. We have assumed that the parallel and perpendicular mean free paths are proportional to the particle Larmor radius, and we have treated each proportionality constant (a,b) as a parameter. We have found that the set (a,b) = (4,2) gives the steady state solution compatible with observations on the intensity and the solar diurnal anisotropy of cosmic rays in 0.5- to 10-GeV range as obtained at the earth. This set of (a,b) corresponds to the ratio of the diffusion coefficients D/sub parallel//D/sub perpendicular/ = 10. In our solution the intensity for the (pre-1980) interplanetary magnetic field (IMF) state where the solar magnetic dipole and the angular velocity vector are parallel is higher than for the (post-1980) state where they are antiparallel, while the phase of the diurnal anisotropy is about 15 hours for the parallel state and about 18 hours for the antiparallel state. We have also reproduced the observed small radial gradient for each IMF state. We discuss the nature of the solution in order to understand the effect of the density gradient drift motion on the cosmic ray distribution

  8. The fluid dynamics of microjet explosions caused by extremely intense X-ray pulses

    Science.gov (United States)

    Stan, Claudiu; Laksmono, Hartawan; Sierra, Raymond; Milathianaki, Despina; Koglin, Jason; Messerschmidt, Marc; Williams, Garth; Demirci, Hasan; Botha, Sabine; Nass, Karol; Stone, Howard; Schlichting, Ilme; Shoeman, Robert; Boutet, Sebastien

    2014-11-01

    Femtosecond X-ray scattering experiments at free-electron laser facilities typically requires liquid jet delivery methods to bring samples to the region of interaction with X-rays. We have imaged optically the damage process in water microjets due to intense hard X-ray pulses at the Linac Coherent Light Source (LCLS), using time-resolved imaging techniques to record movies at rates up to half a billion frames per second. For pulse energies larger than a few percent of the maximum pulse energy available at LCLS, the X-rays deposit energies much larger than the latent heat of vaporization in water, and induce a phase explosion that opens a gap in the jet. The LCLS pulses last a few tens of femtoseconds, but the full evolution of the broken jet is orders of magnitude slower - typically in the microsecond range - due to complex fluid dynamics processes triggered by the phase explosion. Although the explosion results in a complex sequence of phenomena, they lead to an approximately self-similar flow of the liquid in the jet.

  9. Intense soft x-rays from RS Ophiuchi during the 1985 outburst

    International Nuclear Information System (INIS)

    Mason, K.O.; Cordova, F.A.; Bode, M.F.; Barr, P.

    1985-01-01

    Intense soft x-ray emission with a characteristic temperature of a few million degrees has been detected from the recurrent nova RS Oph approximately two months after its January 1985 optical outburst. This is the first detection of x-rays from such a system at outburst. The x-radiation is interpreted as emission from circumstellar gas that is shock heated by the passage of the blast wave from the nova explosion. The rapid decline of the x-ray flux between about 60 and 90 days after the outburst probably occurs because the blast wave has reached the edge of the volume filled, between outbursts, by the stellar wind of the red giant component of the binary system. Residual x-ray emission detected from RS Oph 250 days after the outburst is interpreted as coming from the surface of a white dwarf, at a temperature of approx.300,000K, where thermonuclear burning is persisting. 7 refs., 3 figs

  10. Bright ultrashort x-rays from intense subpicosecond laser-plasma interactions

    International Nuclear Information System (INIS)

    Umstadter, D.

    1995-01-01

    Short-pulse, high-intensity lasers interacting with solid targets make possible the study of a new class of laser-plasma interactions. They are unique because during the ultrashort laser pulse relatively little expansion occurs, and the density scale length remains much less than the laser wavelength. This makes possible the direct deposition of a significant amount of the laser energy at close to solid density. Steep plasma temperature and density gradients subsequently cause rapid cooling, resulting in highly non-equilibrium conditions and the concurrent emission of extremely bright ultrashort x-ray pulses. In this study, the latter are investigated experimentally with temporally and spectrally resolved soft x-ray diagnostics. The emitted x-ray spectra from solid targets with various atomic numbers are characterized for a laser pulse width τ l ∼ 400 fs. These ultrashort x rays may be used as (1) a diagnostic of solid-density plasma conditions, (2) a tool for the study of radiation hydrodynamics in a parameter regime that is otherwise inaccessible, and (3) a source for time-resolved diffraction, spectroscopy, or microscopy studies of transient chemical, biological or physical phenomena

  11. Neutron monitor latitude survey of cosmic ray intensity during the 1986/1987 solar minimum

    International Nuclear Information System (INIS)

    Moraal, H.; Potgieter, M.S.; Stoker, P.H.; van der Walt, A.J.

    1989-01-01

    A latitude survey of the cosmic ray intensity at sea level was conducted during the 1986/1987 solar minimum period on commercial vessels of the South African Marine Corporation (SAFMARINE). The results show that the differential response function for the 1986/1987 solar minimum agrees well with that measured in 1965. Both these response functions are significantly lower than those for 1976 and 1954. This result supports the 22-year modulation cycle as predicted, for example, by models including drift effects of the charged cosmic ray particles in the large-scale interplanetary magnetic field. A crossover of the spectra at rigidities of about 7 GV was also observed. Such a crossover is necessary to explain both the stationary neutron monitor counting rates and the lower-energy balloon and space observations in consecutive solar cycles. copyright American Geophysical Union 1989

  12. 26Al in iron meteorites and the constancy of comic ray intensity in the past

    International Nuclear Information System (INIS)

    Hampel, W.; Schaeffer, O.A.

    1979-01-01

    Cosmic-ray-produced 26 Al in iron meteorites has been measured by low-level γγ-coincidence counting. The 26 Al activities, in dpm/kg, are: Aroos 3.0 +- 1.0, Braunau 2.6 +- 0.5, Kayakent 4.6 +- 1.5, N'Goureyma 4.4 +- 1.1, Okahandja 3.6 +- 0.9, Treysa 4.0 +- 0.5. Exposure ages based on 26 Al/ 21 Ne are in agreement, within experimental error (+-20%) , with those based on 36 Cl/ 36 Ar and 39 Ar/ 38 Ar but the ages based on 40 K/ 41 K are higher by about 50%. The difference in exposure ages is probably caused by a real change of the cosmic ray intensity in the inner solar system. (Auth.)

  13. Results of cosmic ray intensity measurements by the ''Luna-19'' space probe

    International Nuclear Information System (INIS)

    Chuchkov, E.A.; Lyubimov, G.P.; Myagchenkova, O.G.; Novichkova, A.D.; Pereslegina, N.V.; Kontor, N.N.; Nikolaev, A.G.

    1975-01-01

    Results are reviewed of measurements of low energy cosmic-ray characteristics obtained by means of the equipment installed on the ''Luna-19'' space station over the period from 28 November, 1971 to August 20, 1972. Proton fluxes with the energy of 1-5, 5-10, 10-40 MeV were mainly detected. A brief analysis both of individual events in cosmic rays and the general variation of intensity over the period from 1971 to 1972 is presented. Solar and geophysical data are used for the analysis. It is demonstrated that the period of the ''Luna-19'' operation corresponded to the secondary (anomalous) maximum on the decay of the solar activity in the 20th cycle. Assumptions concerning the nature of this maximum are formulated

  14. Gradually Increased Training Intensity Benefits Rehabilitation Outcome after Stroke by BDNF Upregulation and Stress Suppression

    Directory of Open Access Journals (Sweden)

    Jing Sun

    2014-01-01

    Full Text Available Physical training is necessary for effective rehabilitation in the early poststroke period. Animal studies commonly use fixed training intensity throughout rehabilitation and without adapting it to the animals' recovered motor ability. This study investigated the correlation between training intensity and rehabilitation efficacy by using a focal ischemic stroke rat model. Eighty male Sprague-Dawley rats were induced with middle cerebral artery occlusion/reperfusion surgery. Sixty rats with successful stroke were then randomly assigned into four groups: control (CG, n=15, low intensity (LG, n=15, gradually increased intensity (GIG, n=15, and high intensity (HG, n=15. Behavioral tests were conducted daily to evaluate motor function recovery. Stress level and neural recovery were evaluated via plasma corticosterone and brain-derived neurotrophic factor (BDNF concentration, respectively. GIG rats significantly (P<0.05 recovered motor function and produced higher hippocampal BDNF (112.87 ± 25.18 ng/g. GIG and LG rats exhibited similar stress levels (540.63 ± 117.40 nM/L and 508.07 ± 161.30 nM/L, resp., which were significantly lower (P<0.05 than that (716.90 ± 156.48 nM/L of HG rats. Training with gradually increased intensity achieved better recovery with lower stress. Our observations indicate that a training protocol that includes gradually increasing training intensity should be considered in both animal and clinical studies for better stroke recovery.

  15. Effects of High Intensity Interval Training on Increasing Explosive Power, Speed, and Agility

    Science.gov (United States)

    Fajrin, F.; Kusnanik, N. W.; Wijono

    2018-01-01

    High Intensity Interval Training (HIIT) is a type of exercise that combines high-intensity exercise and low intensity exercise in a certain time interval. This type of training is very effective and efficient to improve the physical components. The process of improving athletes achievement related to how the process of improving the physical components, so the selection of a good practice method will be very helpful. This study aims to analyze how is the effects of HIIT on increasing explosive power, speed, and agility. This type of research is quantitative with quasi-experimental methods. The design of this study used the Matching-Only Design, with data analysis using the t-test (paired sample t-test). After being given the treatment for six weeks, the results showed there are significant increasing in explosive power, speed, and agility. HIIT in this study used a form of exercise plyometric as high-intensity exercise and jogging as mild or moderate intensity exercise. Increase was due to the improvement of neuromuscular characteristics that affect the increase in muscle strength and performance. From the data analysis, researchers concluded that, Exercises of High Intensity Interval Training significantly effect on the increase in Power Limbs, speed, and agility.

  16. Increased intensity discrimination thresholds in tinnitus subjects with a normal audiogram

    DEFF Research Database (Denmark)

    Epp, Bastian; Hots, J.; Verhey, J. L.

    2012-01-01

    Recent auditory brain stem response measurements in tinnitus subjects with normal audiograms indicate the presence of hidden hearing loss that manifests as reduced neural output from the cochlea at high sound intensities, and results from mice suggest a link to deafferentation of auditory nerve...... fibers. As deafferentation would lead to deficits in hearing performance, the present study investigates whether tinnitus patients with normal hearing thresholds show impairment in intensity discrimination compared to an audiometrically matched control group. Intensity discrimination thresholds were...... significantly increased in the tinnitus frequency range, consistent with the hypothesis that auditory nerve fiber deafferentation is associated with tinnitus....

  17. Time Integrated Soft X-ray Imaging in High Intensity Laser Experiments (thesis)

    Energy Technology Data Exchange (ETDEWEB)

    Stafford, David [Univ. of California, Davis, CA (United States)

    2009-01-01

    2009 marks a significant achievement and the dawn of a new era in high intensity laser research with the final commissioning of all 192 beams at the National Ignition Facility (NIF). NIF is a department of energy (DOE) funded project more than 10 years in the making located at the Lawrence Livermore National Laboratory (LLNL). The following research was done as one of many preliminary experiments done to prepare for these historic events. The primary focus of the experimental campaign this paper addresses is to test and develop a thermal x-radiation source using a short pulse laser. This data is hoped to provide information about the thermal transport mechanisms important in the development of prediction models in High Energy Density (HED) science. One of several diagnostics fielded was a soft x-ray imager (SXRI) which is detailed in this paper. The SXRI will be used to measure the relative size of the heated region and also the relative level of specific x-ray emissions among several shot and target configurations. The laser system used was the Titan laser located in the Jupiter Laser Facility (JLF) at Lawrence Livermore National Laboratory (LLNL). Titan uses the JLF Janus Nd:glass laser west frontend system with a Optical Parametric Chirped Pulse Amplification (OPCPA) in place of the nanosecond oscillator. The system is capable of producing laser intensities of over a petawatt with several tens of joules delivered in the beam.

  18. GALACTIC COSMIC-RAY INTENSITY MODULATION BY COROTATING INTERACTION REGION STREAM INTERFACES AT 1 au

    Energy Technology Data Exchange (ETDEWEB)

    Guo, X. [State Key Laboratory of Space Weather, National Space Science Center, Chinese Academy of Sciences, Beijing, 100190 (China); Florinski, V. [Center for Space Plasma and Aeronomic Research, University of Alabama, Huntsville, AL 35899 (United States)

    2016-07-20

    We present a new model that couples galactic cosmic-ray (GCR) propagation with magnetic turbulence transport and the MHD background evolution in the heliosphere. The model is applied to the problem of the formation of corotating interaction regions (CIRs) during the last solar minimum from the period between 2007 and 2009. The numerical model simultaneously calculates the large-scale supersonic solar wind properties and its small-scale turbulent content from 0.3 au to the termination shock. Cosmic rays are then transported through the background, and thus computed, with diffusion coefficients derived from the solar wind turbulent properties, using a stochastic Parker approach. Our results demonstrate that GCR variations depend on the ratio of diffusion coefficients in the fast and slow solar winds. Stream interfaces inside the CIRs always lead to depressions of the GCR intensity. On the other hand, heliospheric current sheet (HCS) crossings do not appreciably affect GCR intensities in the model, which is consistent with the two observations under quiet solar wind conditions. Therefore, variations in diffusion coefficients associated with CIR stream interfaces are more important for GCR propagation than the drift effects of the HCS during a negative solar minimum.

  19. GALACTIC COSMIC-RAY INTENSITY MODULATION BY COROTATING INTERACTION REGION STREAM INTERFACES AT 1 au

    International Nuclear Information System (INIS)

    Guo, X.; Florinski, V.

    2016-01-01

    We present a new model that couples galactic cosmic-ray (GCR) propagation with magnetic turbulence transport and the MHD background evolution in the heliosphere. The model is applied to the problem of the formation of corotating interaction regions (CIRs) during the last solar minimum from the period between 2007 and 2009. The numerical model simultaneously calculates the large-scale supersonic solar wind properties and its small-scale turbulent content from 0.3 au to the termination shock. Cosmic rays are then transported through the background, and thus computed, with diffusion coefficients derived from the solar wind turbulent properties, using a stochastic Parker approach. Our results demonstrate that GCR variations depend on the ratio of diffusion coefficients in the fast and slow solar winds. Stream interfaces inside the CIRs always lead to depressions of the GCR intensity. On the other hand, heliospheric current sheet (HCS) crossings do not appreciably affect GCR intensities in the model, which is consistent with the two observations under quiet solar wind conditions. Therefore, variations in diffusion coefficients associated with CIR stream interfaces are more important for GCR propagation than the drift effects of the HCS during a negative solar minimum.

  20. X-ray intensity fluctuation spectroscopy in the energy range from 1 to 4 keV

    Energy Technology Data Exchange (ETDEWEB)

    Retsch, C.C.

    2001-06-01

    X-ray intensity fluctuation spectroscopy was developed in the energy range of 1 to 4 keV and was used to study complex sample structures and dynamics in a liquid-crystal - aerosil dispersion. The advantages of a focusing versus a nonfocusing setup were explored, and the effects of using X-ray energies near absorption edges were investigated to enhance the capabilities of the method. It was found that even though excellent real space resolution and an increase in flux density can be gained from a Fresnel zone plate focusing setup, this usually comes at the expense of speckle contrast. At absorption edges, the speckle contrast is dominated by the imaginary part of the sample's index of refraction and therefore varies in a way similar to the total transmitted intensity. Employing these results, the dynamics of a dispersion of low-density silica aerosil in octylcyanobiphenyl (8CB) were studied. It was found that the known cross-over behavior of 8CB - aerosil samples towards the 3d-XY universality class should be understood as the coupling of the aerosil-gel dynamics to the dynamics of the director fluctuations in the liquid-crystal. This work indicates that the aerosil-gel mimics and dampens these director fluctuations and thus, by suppressing the director fluctuations, achieves a pure 3d-XY system. (orig.)

  1. Aerogel Cherenkov detector for characterizing the intense flash x-ray source, Cygnus, spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y., E-mail: yhkim@lanl.gov; Herrmann, H. W.; McEvoy, A. M.; Young, C. S.; Hamilton, C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Schwellenbach, D. D.; Malone, R. M.; Kaufman, M. I.; Smith, A. S. [National Security Technologies, LLC, Los Alamos, New Mexico 87544 (United States)

    2016-11-15

    An aerogel Cherenkov detector is proposed to measure the X-ray energy spectrum from the Cygnus—intense flash X-ray source operated at the Nevada National Security Site. An array of aerogels set at a variety of thresholds between 1 and 3 MeV will be adequate to map out the bremsstrahlung X-ray production of the Cygnus, where the maximum energy of the spectrum is normally around 2.5 MeV. In addition to the Cherenkov radiation from aerogels, one possible competing light-production mechanism is optical transition radiation (OTR), which may be significant in aerogels due to the large number of transitions from SiO{sub 2} clusters to vacuum voids. To examine whether OTR is a problem, four aerogel samples were tested using a mono-energetic electron beam (varied in the range of 1–3 MeV) at NSTec Los Alamos Operations. It was demonstrated that aerogels can be used as a Cherenkov medium, where the rate of the light production is about two orders magnitude higher when the electron beam energy is above threshold.

  2. Measurements of decay heat and gamma-ray intensity of spent LWR fuel assemblies

    International Nuclear Information System (INIS)

    Vogt, J.; Agrenius, L.; Jansson, P.; Baecklin, A.; Haakansson, A.; Jacobsson, S.

    1999-01-01

    Calorimetric measurements of the decay heat of a number of BWR and PWR fuel assemblies have been performed in the pools at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel, CLAB. Gamma-ray measurements, using high-resolution gamma-ray spectroscopy (HRGS), have been carried out on the same fuel assemblies in order to test if it is possible to find a simple and accurate correlation between the 137 CS -intensity and the decay heat for fuel with a cooling time longer than 10-12 years. The results up to now are very promising and may ultimately lead to a qualified method for quick and accurate determination of the decay heat of old fuel by gamma-ray measurements. By means of the gamma spectrum the operator declared data on burnup, cooling time and initial enrichment can be verified as well. CLAB provides a unique opportunity in the world to follow up the decay heat of individual fuel assemblies during several decades to come. The results will be applicable for design and operation of facilities for wet and dry interim storage and subsequent encapsulation for final disposal of the fuel. (author)

  3. X-ray tomography investigation of intensive sheared Al–SiC metal matrix composites

    Energy Technology Data Exchange (ETDEWEB)

    De Giovanni, Mario; Warnett, Jason M.; Williams, Mark A. [WMG, University of Warwick, Coventry CV4 7AL (United Kingdom); Haribabu, Nadendla [BCAST, Brunel University London, Uxbridge UB8 3PH (United Kingdom); Srirangam, Prakash, E-mail: p.srirangam@warwick.ac.uk [WMG, University of Warwick, Coventry CV4 7AL (United Kingdom)

    2015-12-15

    X-ray computed tomography (XCT) was used to characterise three dimensional internal structure of Al–SiC metal matrix composites. The alloy composite was prepared by casting method with the application of intensive shearing to uniformly disperse SiC particles in the matrix. Visualisation of SiC clusters as well as porosity distribution were evaluated and compared with non-shearing samples. Results showed that the average particle size as well as agglomerate size is smaller in sheared sample compared to conventional cast samples. Further, it was observed that the volume fraction of porosity was reduced by 50% compared to conventional casting, confirming that the intensive shearing helps in deagglomeration of particle clusters and decrease in porosity of Al–SiC metal matrix composites. - Highlights: • XCT was used to visualise 3D internal structure of Al-SiC MMC. • Al-SiC MMC was prepared by casting with the application of intensive shearing. • SiC particles and porosity distribution were evaluated. • Results show shearing deagglomerates particle clusters and reduces porosity in MMC.

  4. Increasing potential for intense tropical and subtropical thunderstorms under global warming.

    Science.gov (United States)

    Singh, Martin S; Kuang, Zhiming; Maloney, Eric D; Hannah, Walter M; Wolding, Brandon O

    2017-10-31

    Intense thunderstorms produce rapid cloud updrafts and may be associated with a range of destructive weather events. An important ingredient in measures of the potential for intense thunderstorms is the convective available potential energy (CAPE). Climate models project increases in summertime mean CAPE in the tropics and subtropics in response to global warming, but the physical mechanisms responsible for such increases and the implications for future thunderstorm activity remain uncertain. Here, we show that high percentiles of the CAPE distribution (CAPE extremes) also increase robustly with warming across the tropics and subtropics in an ensemble of state-of-the-art climate models, implying strong increases in the frequency of occurrence of environments conducive to intense thunderstorms in future climate projections. The increase in CAPE extremes is consistent with a recently proposed theoretical model in which CAPE depends on the influence of convective entrainment on the tropospheric lapse rate, and we demonstrate the importance of this influence for simulated CAPE extremes using a climate model in which the convective entrainment rate is varied. We further show that the theoretical model is able to account for the climatological relationship between CAPE and a measure of lower-tropospheric humidity in simulations and in observations. Our results provide a physical basis on which to understand projected future increases in intense thunderstorm potential, and they suggest that an important mechanism that contributes to such increases may be present in Earth's atmosphere. Published under the PNAS license.

  5. Uncertainty about the intensity of impending pain increases ensuing pain responses in congenital blindness

    DEFF Research Database (Denmark)

    Holten-Rossing, S.; Slimani, H.; Ptito, M.

    2018-01-01

    about the intensity of a pending painful stimulus affects pain differently in congenitally blind and sighted control subjects. We measured pain and anxiety in a group of 11 congenitally blind and 11 age- and sex-matched normal sighted control participants. Painful stimuli were delivered under two...... psychological conditions, whereby participants were either certain or uncertain about the intensity of a pending noxious stimuli. Although both blind and sighted participants had increased anxiety ratings in the uncertain condition, pain ratings increased only in the congenitally blind participants. Our data...

  6. Anomalous decrease in X-ray diffraction intensities of Cu-Ni-Al-Co-Cr-Fe-Si alloy systems with multi-principal elements

    International Nuclear Information System (INIS)

    Yeh, J.-W.; Chang, S.-Y.; Hong, Y.-D.; Chen, S.-K.; Lin, S.-J.

    2007-01-01

    With an aim to understand the great reduction in the X-ray diffraction (XRD) intensities of high-entropy alloys, a series of Cu-Ni-Al-Co-Cr-Fe-Si alloys with systematic addition of principal elements from pure element to seven elements was investigated for quantitative analysis of XRD intensities. The variation of XRD peak intensities of the alloy system is similar to that caused by thermal effect, but the intensities further drop beyond the thermal effect with increasing number of incorporated principal elements. An intrinsic lattice distortion effect caused by the addition of multi-principal elements with different atomic sizes is expected for the anomalous decrease in XRD intensities. The mathematical factor of this distortion effect for the modification of XRD structure factor is formulated analogue to that of thermal effect

  7. Why did China's energy intensity increase during 1998-2006. Decomposition and policy analysis

    International Nuclear Information System (INIS)

    Zhao, Xiaoli; Ma, Chunbo; Hong, Dongyue

    2010-01-01

    Despite the fact that China's energy intensity has continuously decreased during the 1980s and mostly 1990s, the decreasing trend has reversed since 1998 and the past few years have witnessed rapid increase in China's energy intensity. We firstly conduct an index decomposition analysis to identify the key forces behind the increase. It is found that: (1) the high energy demand in industrial sectors is mainly attributed to expansion of production scale, especially in energy-intensive industries; (2) energy saving mainly comes from efficiency improvement, with energy-intensive sectors making the largest contribution; and (3) a heavier industrial structure also contributes to the increase. This study also makes the first attempt to bridge the quantitative decomposition analysis with qualitative policy analyses and fill the gap between decomposition results and policy relevance in previous work. We argue that: (1) energy efficiency improvement in energy-intensive sectors is mainly due to the industrial policies that have been implemented in the past few years; (2) low energy prices have directly contributed to high industrial energy consumption and indirectly to the heavy industrial structure. We provide policy suggestions in the end. (author)

  8. Analysis of the Relationship Between the Solar X-Ray Radiation Intensity and the D-Region Electron Density Using Satellite and Ground-Based Radio Data

    Science.gov (United States)

    Nina, Aleksandra; Čadež, Vladimir M.; Bajčetić, Jovan; Mitrović, Srdjan T.; Popović, Luka Č.

    2018-04-01

    Increases in the X-ray radiation that is emitted during a solar X-ray flare induce significant changes in the ionospheric D region. Because of the numerous complex processes in the ionosphere and the characteristics of the radiation and plasma, the causal-consequential relationship between the X-ray radiation and ionospheric parameters is not easily determined. In addition, modeling the ionospheric D-region plasma parameters is very difficult because of the lack of data for numerous time- and space-dependent physical quantities. In this article we first give a qualitative analysis of the relationship between the electron density and the recorded solar X-ray intensity. After this, we analyze the differences in the relationships between the D-region response and various X-ray radiation properties. The quantitative study is performed for data observed on 5 May 2010 in the time period between 11:40 UT - 12:40 UT when the GOES 14 satellite detected a considerable X-ray intensity increase. Modeling the electron density is based on characteristics of the 23.4 kHz signal emitted in Germany and recorded by the receiver in Serbia.

  9. High-resolution imaging of coronary calcifications by intense low-energy fluoroscopic X-ray obtained from synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsuka, S.; Sugishita, Y.; Takeda, T.; Itai, Y.; Tada, J.; Hyodo, K.; Ando, M. [Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan). Dept. of Cardiology

    2000-07-01

    In order to obtain an intense monochromatic low-energy X-ray from synchrotron radiation (SR) and apply it to detect coronary calcifications, the SR beam was reflected with a silicon crystal to be expanded (150 mm in height and 80 mm in width) and to be monochromatized at an energy level of 37 keV. The X-ray was intermittently irradiated to obtain dynamic imaging of 30 images/s. Images were recorded by a digital fluorography system. The low-energy X-ray from SR sharply visualized calcification of coronary arteries, while conventional X-ray could not visualize coronary calcification. The intense monochromatic low-energy X-ray from SR is sensitive, has high-resolution for imaging coronary calcification and may serve as a screening method for coronary artery disease.

  10. Cosmic ray nucleonic intensity in low-amplitude days during the passage of high-speed solar wind streams

    International Nuclear Information System (INIS)

    Agarwal, R.; Mishra, R.K.; Tiwari, S.; or rm_jbp@yahoo.co.in

    2008-01-01

    One of the most striking features of solar wind is its organization into high- and low- speed streams. It is now well established that the passage over the Earth of high-speed solar wind streams leads to geomagnetic disturbances. The high-speed plasma streams are thus a key element in the complex chain of events that link geomagnetic activity to the solar activity and are therefore of great interest to the solar terrestrial physics. Two types of high-speed solar wind streams - coronal-hole-associated (or corotating) and flare-generated - were studied based on magnetic field and solar wind plasma parameters. In the work, the dependence was obtained for cosmic ray (CR) depressions due to high-speed solar wind streams during low-amplitude days. The CR nucleonic intensity data were subjected to the superposed epoch analysis with respect to the start time of high-speed solar wind streams. It was found that streams of both types produce significant deviations in the CR intensity during low-amplitude anisotropic wave train events. At the onset of such streams the CR intensity reaches its minimum during low-amplitude events and then increases statistically. (Authors)

  11. Systems for increasing the sensitivity of gamma-ray imagers

    Science.gov (United States)

    Mihailescu, Lucian; Vetter, Kai M.; Chivers, Daniel H.

    2012-12-11

    Systems that increase the position resolution and granularity of double sided segmented semiconductor detectors are provided. These systems increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

  12. The potential of detecting intermediate-scale biomass and canopy interception in a coniferous forest using cosmic-ray neutron intensity measurements and neutron transport modeling

    Science.gov (United States)

    Andreasen, M.; Looms, M. C.; Bogena, H. R.; Desilets, D.; Zreda, M. G.; Sonnenborg, T. O.; Jensen, K. H.

    2014-12-01

    The water stored in the various compartments of the terrestrial ecosystem (in snow, canopy interception, soil and litter) controls the exchange of the water and energy between the land surface and the atmosphere. Therefore, measurements of the water stored within these pools are critical for the prediction of e.g. evapotranspiration and groundwater recharge. The detection of cosmic-ray neutron intensity is a novel non-invasive method for the quantification of continuous intermediate-scale soil moisture. The footprint of the cosmic-ray neutron probe is a hemisphere of a few hectometers and subsurface depths of 10-70 cm depending on wetness. The cosmic-ray neutron method offers measurements at a scale between the point-scale measurements and large-scale satellite retrievals. The cosmic-ray neutron intensity is inversely correlated to the hydrogen stored within the footprint. Overall soil moisture represents the largest pool of hydrogen and changes in the soil moisture clearly affect the cosmic-ray neutron signal. However, the neutron intensity is also sensitive to variations of hydrogen in snow, canopy interception and biomass offering the potential to determine water content in such pools from the signal. In this study we tested the potential of determining canopy interception and biomass using cosmic-ray neutron intensity measurements within the framework of the Danish Hydrologic Observatory (HOBE) and the Terrestrial Environmental Observatories (TERENO). Continuous measurements at the ground and the canopy level, along with profile measurements were conducted at towers at forest field sites. Field experiments, including shielding the cosmic-ray neutron probes with cadmium foil (to remove lower-energy neutrons) and measuring reference intensity rates at complete water saturated conditions (on the sea close to the HOBE site), were further conducted to obtain an increased understanding of the physics controlling the cosmic-ray neutron transport and the equipment used

  13. The relative-intensity method of X-ray fluorescence analysis and its application to soils and rocks

    International Nuclear Information System (INIS)

    Childs, C.W.; Furkert, R.J.

    1974-01-01

    The relative-intensity X-ray fluorescence method of analysis of rock and soil samples has been investigated and compared with the net-intensity method. Strong, coherently scattered radiation originating from the X-ray tube is shown to be preferable to background radiation as an internal standard, and scattered radiation measured at one wavelength can usefully be applied in the determination of several elements. When the concentrations of an element in two soil samples of different composition (for example concretions and the soil adjacent to them) are compared, the ratio of the relative intensities may be different from the ratio of net intensities by a factor of about two. The concentrations of manganese in thirteen standard rock samples determined by the relative-intensity method are within or very close to the ranges of values reported previously

  14. Secular variation of cosmic ray intensity recorded in the radiocarbon concentration of tree rings

    International Nuclear Information System (INIS)

    Kigoshi, K.

    1978-01-01

    Study of the secular variations of cosmic ray intensity on the basis of the secular variations of atmospheric radiocarbon concentration in 8000 years is considered. The data on the radiocarbon concentration is received by three laboratories using the dendrochronologically dated tree ring samples. In order to use the data the variations due to geochemical process must be eliminated. From this point of view the climatic effect on the atmospheric radiocarbon concenttration is estimated using the data on sunspot number and global surface temperature during 1650-1800 y. The barge influence of climate on the atmospheric radiocarbon concentration syggests the small contribution of change of radiocarbon production rate to the short-period fluctuations in the atmospheric radiocarbon concentration. Elimination of variations caused by climate and sunspot activities from the variations in atmospheric radiocarbon concentration gives a long-term scale of its concentration which agrees well to the observed paleo-geomagnetic data

  15. The intermediate polar GK Persei: An unstable relation of the X-ray and the optical intensities in a series of outbursts

    Science.gov (United States)

    Šimon, V.

    2015-03-01

    Context. GK Per is an intermediate polar that has been displaying dwarf nova outbursts since the middle of the twentieth century. Aims: I analyzed a series of such outbursts in the optical and X-ray bands. I pay attention to the relation of intensities of the optical and X-ray emissions, and its reproducibility in a series of these consecutive outbursts. Methods: This analysis uses the data from the BAT/Swift, ASM/RXTE, AAVSO, and AFOEV databases. It investigates the relation of the time evolution of the profiles of outbursts in the individual bands (hard X-ray, medium/hard X-ray, and optical). Results: This analysis shows that the X-ray intensity steeply rises only in the start of the optical outburst and steeply declines only when the optical outburst comes to its end. However, the 1.5-50 keV band intensity saturates and balances on a plateau during the outburst. (The longer the outburst, the longer its plateau.) The peak X-ray intensities of this series display a significantly narrower range than the optical ones (a factor of about two versus a factor of about eight). This implies a discrepancy between the mass flow through the disk and the production of the X-ray emission via bremsstrahlung at the polar caps of the white dwarf. This discrepancy is the largest in the time of the peak optical intensity when the whole disk (or at least its inner part) is in the hot state and the flow of matter through the disk is the greatest. This study shows that a series of outbursts constitutes more general properties of this discrepancy. I argue that the saturation of the X-ray luminosity in outburst cannot be caused by a dominant increase in X-ray absorption. In the interpretation, large structural changes of the accreting regions at the magnetic poles of the white dwarf occur during the outburst. A buried shock proposed by some authors for polars is also promising for explaining the X-ray light curves of outbursts of GK Per. This research made use of the BAT/Swift, ASM

  16. Intense gamma-ray lines from hidden vector dark matter decay

    Energy Technology Data Exchange (ETDEWEB)

    Arina, Chiara; Hambye, Thomas [Universite Libre de Bruxelles (Belgium). Service de Physique Theorique; Ibarra, Alejandro [Technische Univ. Muenchen, Garching (Germany). Physik-Department; Weniger, Christoph [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2009-12-15

    Scenarios with hidden, spontaneously broken, non-abelian gauge groups contain a natural dark matter candidate, the hidden vector, whose longevity is due to an accidental custodial symmetry in the renormalizable Lagrangian. Nevertheless, non-renormalizable dimension six operators break the custodial symmetry and induce the decay of the dark matter particle at cosmological times. We discuss in this paper the cosmic ray signatures of this scenario and we show that the decay of hidden vector dark matter particles generically produce an intense gamma ray line which could be observed by the Fermi-LAT experiment, if the scale of custodial symmetry breaking is close to the Grand Unification scale. This gamma line proceeds directly from a tree level dark matter 2-body decay in association with a Higgs boson. Within this model we also perform a determination of the relic density constraints taking into account the dark matter annihilation processes with one dark matter particle in the final state. The corresponding direct detection rates can be easily of order the current experimental sensitivities. (orig.)

  17. Intense gamma-ray lines from hidden vector dark matter decay

    International Nuclear Information System (INIS)

    Arina, Chiara; Hambye, Thomas

    2009-12-01

    Scenarios with hidden, spontaneously broken, non-abelian gauge groups contain a natural dark matter candidate, the hidden vector, whose longevity is due to an accidental custodial symmetry in the renormalizable Lagrangian. Nevertheless, non-renormalizable dimension six operators break the custodial symmetry and induce the decay of the dark matter particle at cosmological times. We discuss in this paper the cosmic ray signatures of this scenario and we show that the decay of hidden vector dark matter particles generically produce an intense gamma ray line which could be observed by the Fermi-LAT experiment, if the scale of custodial symmetry breaking is close to the Grand Unification scale. This gamma line proceeds directly from a tree level dark matter 2-body decay in association with a Higgs boson. Within this model we also perform a determination of the relic density constraints taking into account the dark matter annihilation processes with one dark matter particle in the final state. The corresponding direct detection rates can be easily of order the current experimental sensitivities. (orig.)

  18. Windowless microfluidic platform based on capillary burst valves for high intensity x-ray measurements

    International Nuclear Information System (INIS)

    Vig, Asger Laurberg; Enevoldsen, Nikolaj; Thilsted, Anil Haraksingh; Eriksen, Johan; Kristensen, Anders; Haldrup, Kristoffer; Feidenhans'l, Robert; Nielsen, Martin Meedom

    2009-01-01

    We propose and describe a microfluidic system for high intensity x-ray measurements. The required open access to a microfluidic channel is provided by an out-of-plane capillary burst valve (CBV). The functionality of the out-of-plane CBV is characterized with respect to the diameter of the windowless access hole, ranging from 10 to 130 μm. Maximum driving pressures from 22 to 280 mbar corresponding to refresh rates of the exposed sample from 300 Hz to 54 kHz is demonstrated. The microfluidic system is tested at beamline ID09b at the ESRF synchrotron radiation facility in Grenoble, and x-ray scattering measurements are shown to be feasible and to require only very limited amounts of sample, <1 ml/h of measurements without recapturing of sample. With small adjustments of the present chip design, scattering angles up to 30 deg. can be achieved without shadowing effects and integration on-chip mixing and spectroscopy appears straightforward.

  19. Intense gamma-ray lines from hidden vector dark matter decay

    International Nuclear Information System (INIS)

    Arina, Chiara; Hambye, Thomas; Ibarra, Alejandro; Weniger, Christoph

    2010-01-01

    Scenarios with hidden, spontaneously broken, non-abelian gauge groups contain a natural dark matter candidate, the hidden vector, whose longevity is due to an accidental custodial symmetry in the renormalizable Lagrangian. Nevertheless, non-renormalizable dimension six operators break the custodial symmetry and induce the decay of the dark matter particle at cosmological times. We discuss in this paper the cosmic ray signatures of this scenario and we show that the decay of hidden vector dark matter particles generically produce an intense gamma ray line which could be observed by the Fermi-LAT experiment, if the scale of custodial symmetry breaking is close to the Grand Unification scale. This gamma line proceeds directly from a tree level dark matter 2-body decay in association with a Higgs boson. Within this model we also perform a determination of the relic density constraints taking into account the dark matter annihilation processes with one dark matter particle in the final state. The corresponding direct detection rates can be easily of order the current experimental sensitivities

  20. Contribution of inner shell Compton ionization to the X-ray fluorescence line intensity

    Science.gov (United States)

    Fernández, Jorge E.; Scot, Viviana; Di Giulio, Eugenio

    2016-10-01

    The Compton effect is a potential ionization mechanism of atoms. It produces vacancies in inner shells that are filled with the same mechanism of atomic relaxation as the one following photo-absorption. This contribution to X-ray fluorescence emission is frequently neglected because the total Compton cross-section is apparently much lower than the photoelectric one at useful X-ray energies. However, a more careful analysis suggests that is necessary to consider single shell cross sections (instead of total cross sections) as a function of energy. In this article these Compton cross sections are computed for the shells K, L1-L3 and M1-M5 in the framework of the impulse approximation. By comparing the Compton and the photoelectric cross-section for each shell it is then possible to determine the extent of the Compton correction to the intensity of the corresponding characteristic lines. It is shown that for the K shell the correction becomes relevant for excitation energies which are too high to be influent in X-ray spectrometry. In contrast, for L and M shells the Compton contribution is relevant for medium-Z elements and medium energies. To illustrate the different grades of relevance of the correction, for each ionized shell, the energies for which the Compton contribution reaches the extent levels of 1, 5, 10, 20, 50 and 100% of the photoelectric one are determined for all the elements with Z = 11-92. For practical applications it is provided a simple formula and fitting coefficients to compute average correction levels for the shells considered.

  1. Propagation and scattering of high-intensity X-ray pulses in dense atomic gases and plasmas

    International Nuclear Information System (INIS)

    Weninger, Clemens

    2015-10-01

    Nonlinear spectroscopy in the X-ray domain is a promising technique to explore the dynamics of elementary excitations in matter. X-rays provide an element specificity that allows them to target individual chemical elements, making them a great tool to study complex molecules. The recent advancement of X-ray free electron lasers (XFELs) allows to investigate non-linear processes in the X-ray domain for the first time. XFELs provide short femtosecond X-ray pulses with peak powers that exceed previous generation synchrotron X-ray sources by more than nine orders of magnitude. This thesis focuses on the theoretical description of stimulated emission processes in the X-ray regime in atomic gases. These processes form the basis for more complex schemes in molecules and provide a proof of principle for nonlinear X-ray spectroscopy. The thesis also includes results from two experimental campaigns at the Linac Coherent Light Source and presents the first experimental demonstration of stimulated X-ray Raman scattering. Focusing an X-ray free electron laser beam into an elongated neon gas target generates an intense stimulated X-ray emission beam in forward direction. If the incoming X-rays have a photon energy above the neon K edge, they can efficiently photo-ionize 1s electrons and generate short-lived core excited states. The core-excited states decay mostly via Auger decay but have a small probability to emit a spontaneous X-ray photon. The spontaneous emission emitted in forward direction can stimulate X-ray emission along the medium and generate a highly directional and intense X-ray laser pulse. If the photon energy of the incoming X-rays however is below the ionization edge in the region of the pre-edge resonance the incoming X-rays can be inelastically scattered. This spontaneous X-ray Raman scattering process has a very low probability, but the spontaneously scattered photons in the beginning of the medium can stimulate Raman scattering along the medium. The

  2. The velocity of light intensity increase modulates the photoprotective response in coastal diatoms.

    Directory of Open Access Journals (Sweden)

    Vasco Giovagnetti

    Full Text Available In aquatic ecosystems, the superimposition of mixing events to the light diel cycle exposes phytoplankton to changes in the velocity of light intensity increase, from diurnal variations to faster mixing-related ones. This is particularly true in coastal waters, where diatoms are dominant. This study aims to investigate if coastal diatoms differently activate the photoprotective responses, xanthophyll cycle (XC and non-photochemical fluorescence quenching (NPQ, to cope with predictable light diel cycle and unpredictable mixing-related light variations. We compared the effect of two fast light intensity increases (simulating mixing events with that of a slower increase (corresponding to the light diel cycle on the modulation of XC and NPQ in the planktonic coastal diatom Pseudo-nitzschia multistriata. During each light treatment, the photon flux density (PFD progressively increased from darkness to five peaks, ranging from 100 to 650 µmol photons m-2 s-1. Our results show that the diel cycle-related PFD increase strongly activates XC through the enhancement of the carotenoid biosynthesis and induces a moderate and gradual NPQ formation over the light gradient. In contrast, during mixing-related PFD increases, XC is less activated, while higher NPQ rapidly develops at moderate PFD. We observe that together with the light intensity and its increase velocity, the saturation light for photosynthesis (Ek is a key parameter in modulating photoprotection. We propose that the capacity to adequately regulate and actuate alternative photoprotective 'safety valves' in response to changing velocity of light intensity increase further enhances the photophysiological flexibility of diatoms. This might be an evolutionary outcome of diatom adaptation to turbulent marine ecosystems characterized by unpredictable mixing-related light changes over the light diel cycle.

  3. Calculated L-shell x-ray line intensities for proton and helium ion impact

    International Nuclear Information System (INIS)

    Cohen, D.D.; Harrigan, M.

    1986-01-01

    Theoretical L-shell X-ray line intensities have been calculated for proton and helium bombardment of atoms from nickel (Z 2 = 28) to curium (Z 2 = 96). The ionization cross sections for the three L subshells were obtained from the recent calculations by Cohen and Harrigan in the ECPSSR theory, which uses the plane-wave Born approximation (PWBA) with corrections for energy loss (E), Coulomb deflection (C), perturbed-stationary-state (PSS), and relativistic (R) effects. The fluorescence yields and Coster-Kronig transition probabilities were taken from M. O. Krause (Phys. Chem. Ref. Data 8, 307 (1979)) and the L-subshell emission rates from S. I. Salem, S. L. Panosian, and R. A. Krause (Atomic Data and Nuclear Data Tables 14, 91 (1974)). The line intensities Ll, Lα, Leta, Lβ 1 to Lβ 6 , Lβ/sub 9,10/, and Lγ 1 to Lgg 6 are tabulated for selected ion energies from 0.2 to 10 MeV

  4. A theoretical model predicting the intensity of emitted light per unit of x-ray exposure in radiographic screens

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukos, S; Kateris, A; Kalivas, N; Spyrou, G; Panayiotakis, G [Department of Medical Physics, School of Medicine, University of Patras, 265 00 pAtras (Greece); Kandarakis, I; Gavouras, D [Department of Medical Instrumentation Technology, Technological Educational Institution of Athens (Greece)

    1999-12-31

    A theoretical model predicting the intensity of light emitted by x-ray imaging phosphor screens per unit of area and time over incident x-ray flux (absolute efficiency) was developed. The model takes into account : A) the structure of the screens which consists of luminescent grains embedded in a binding matrix. B) the direct deposition of energy by x-ray absorption effects.. C) the re-absorption of K fluorescence characteristic x-rays produced when the x-ray energy exceeds the energy of the K absorption edge of the phosphor material. To test the model a set of (Gd,La)2O2S:Tb phosphor screens was prepared by sedimentation in the laboratory. Experimental absolute efficiency data were obtained at x-ray tube voltage range from 40 to 160 kVp. The coincidence between experimental and theoretical results were satisfactory. (authors) 7 refs., 4 figs.

  5. Increasing land-use intensity reverses the relative occupancy of two quadrupedal scavengers.

    Directory of Open Access Journals (Sweden)

    Joshua P Twining

    Full Text Available Human land use is continuously altering the natural environment, yet the greater ecological implications of this change for many groups that are key to healthy ecosystem functioning remains uncharacterised in the tropics. Terrestrial scavenging vertebrates are one such group, providing integral ecosystem services through the removal of carrion which is a crucial component of both nutrient cycling and disease dynamics. To explore how anthropogenic processes may affect forest scavengers, we investigated the changes in the relative occupancy of two important terrestrial scavengers along a gradient of land use intensity, ranging from protected forest to oil palm plantation in Borneo. We found the Malay civet (Viverra tangalunga had highest, albeit variable, occupancy in areas of low land use intensity and the Southeast Asian water monitor (Varanus salvator macromaculatus had highest occupancy in areas of high land use intensity. Land use had no effect on the combined occupancy of the two species. In high land use intensity sites, individual water monitors were larger and had better body condition, but at population level had a highly biased sex ratio with more males than females and increased signs of intraspecific conflict. We did not assess scavenging rate or efficiency as a process, but the high occupancy rates and apparent health of the scavengers in high land use intensity landscapes suggests this ecological process is robust to land use change.

  6. Plasma Irisin Modestly Increases during Moderate and High-Intensity Afternoon Exercise in Obese Females

    Science.gov (United States)

    Winn, Nathan C.; Grunewald, Zachary I.; Liu, Ying; Heden, Timothy D.; Nyhoff, Lauren M.; Kanaley, Jill A.

    2017-01-01

    Background and Purpose Irisin is an exercise-responsive myokine that has been proposed to exert anti-obesity benefits; yet its response during exercise in obese women is not described. This study characterized plasma irisin levels during a single bout of afternoon isocaloric-exercise of different intensities (moderate- vs high-intensity) in obese females. Methods Eleven obese females participated in 3 randomized study days beginning at 1600h: 1) no exercise (NoEx), 2) moderate exercise (ModEx; 55%VO2max) and 3) high intensity interval exercise (IntEx; 4 min (80%VO2max)/3 min (50% VO2max). Frequent blood samples were analyzed for glucose and lactate (whole-blood), and insulin, c-peptide, glucagon, and irisin (plasma) throughout 190 min of testing. Results Plasma irisin increased above baseline during ModEx and IntEx (P0.05). Peak irisin levels during ModEx and IntEx exercise were 11.9± 3.4% and 12.3 ± 4.1% relative to baseline (Pexercise intensities (P>0.05). Irisin levels remained elevated above resting for 125 minutes post-exercise during ModEx, whereas levels returned to baseline within 15 minutes post-exercise during IntEx. Similarly, no associations were found between plasma irisin levels and circulating lactate, glucose, insulin, c-peptide, or glucagon among study days (P>0.05). However, there was an inverse association between basal irisin and lean mass (r = -0.70, P = 0.01). Conclusion A single bout of moderate and high intensity afternoon exercise induces modest increases in circulating irisin concentrations during exercise; however the regulation post-exercise appears to be dimorphic between exercise intensity in obese females. Future studies are needed to compare morning and afternoon exercise on irisin secretion. PMID:28125733

  7. Pulsed x-ray imaging of high-density objects using a ten picosecond high-intensity laser driver

    Science.gov (United States)

    Rusby, D. R.; Brenner, C. M.; Armstrong, C.; Wilson, L. A.; Clarke, R.; Alejo, A.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Mirfayzi, S. R.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.

    2016-10-01

    Point-like sources of X-rays that are pulsed (sub nanosecond), high energy (up to several MeV) and bright are very promising for industrial and security applications where imaging through large and dense objects is required. Highly penetrating X-rays can be produced by electrons that have been accelerated by a high intensity laser pulse incident onto a thin solid target. We have used a pulse length of 10ps to accelerate electrons to create a bright x-ray source. The bremsstrahlung temperature was measured for a laser intensity from 8.5-12×1018 W/cm2. These x-rays have sequentially been used to image high density materials using image plate and a pixelated scintillator system.

  8. Energy dependence of photon-induced L-shell x-ray intensity ratios in some high-Z elements

    Energy Technology Data Exchange (ETDEWEB)

    Shatendra, K; Allawadhi, K L; Sood, B S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1983-12-14

    The L-shell x-ray intensity ratios in Au, Pb, Th and U at various photon energies have been measured and their energy dependence is studied. A comparison of the experimental values is made with those calculated using the x-ray emission rates and subshell photoelectric cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities and fairly good agreement is observed.

  9. Increase in compton scattering of gamma rays passing along metal surface

    International Nuclear Information System (INIS)

    Grigor'ev, A.N.; Bilyk, Z.V.; Sakun, A.V.; Marushchenko, V.V.; Chernyavskij, O.Yu.; Litvinov, Yu.V.

    2014-01-01

    The paper considers experimental study of changes in energy of 137 Cs gamma source as gamma rays pass along metal surface. Decrease in gamma energy was examined by reducing the number of gamma rays in the complete absorption peak to the Compton length level and increasing the Compton effect. The number of gamma rays in the complete absorption peak decreases by 3.5 times in the angle range under study

  10. Exposure assessment of neonates in israel to x-ray radiation during hospitalization at neonatal intensive care unit

    International Nuclear Information System (INIS)

    Datz, H.

    2005-03-01

    Nowadays nearly 10% of all births in western countries are premature. In the last decade, there has been an increase of 45% in the number of neonates that were born in Israel. At the same time, the survival of neonates, especially those with very low birth weight, VLBW, (less than 1,500 gr), has increased dramatically. Diagnostic radiology plays an important role in the assessment and treatment of neonates requiring intensive care. During their prolonged and complex hospitalization, these infants are exposed to multiple radiographic examinations involving X-ray radiation. The extent of the examinations that the infant undergoes depends on its birth weight, gestational age and its medical problems, where most of the treatment effort is focused especially on VLBW neonates. Most of the diagnostic X-ray examinations taken during the hospitalization of neonates in the neonatal intensive care unit (NICU) consist of imaging of the respiratory and gastrointestinal systems, namely, the chest and abdomen. The imaging process is done using mobile X-ray units located at the NICUs. Due to their long hospitalization periods and complex medical condition, all neonates, and neonates with VLBW in particular, are exposed to a much higher level of diagnostic radiation, compared to normal newborns. The goal of this research was to assess the extent of the exposure of neonates in Israel to X-ray radiation during their hospitalization at the neonatal intensive care unit. Five NICUs, located at different geographical zones in Israel and treating 20% of all newborns in Israel every year, participated in this research. The research was conducted in three phases: Phase I: Collection of information on radiographic techniques and exposure parameters (e.g. kV, mAs, focus to skin distance (FSD), examination borders). 499 X-ray examinations (from 157 neonates) were evaluated for necessary and unnecessary exposure of the neonate's organs to X-ray radiation during these examinations. Phase II

  11. A photodiode amplifier system for pulse-by-pulse intensity measurement of an x-ray free electron laser.

    Science.gov (United States)

    Kudo, Togo; Tono, Kensuke; Yabashi, Makina; Togashi, Tadashi; Sato, Takahiro; Inubushi, Yuichi; Omodani, Motohiko; Kirihara, Yoichi; Matsushita, Tomohiro; Kobayashi, Kazuo; Yamaga, Mitsuhiro; Uchiyama, Sadayuki; Hatsui, Takaki

    2012-04-01

    We have developed a single-shot intensity-measurement system using a silicon positive-intrinsic-negative (PIN) photodiode for x-ray pulses from an x-ray free electron laser. A wide dynamic range (10(3)-10(11) photons/pulse) and long distance signal transmission (>100 m) were required for this measurement system. For this purpose, we developed charge-sensitive and shaping amplifiers, which can process charge pulses with a wide dynamic range and variable durations (ns-μs) and charge levels (pC-μC). Output signals from the amplifiers were transmitted to a data acquisition system through a long cable in the form of a differential signal. The x-ray pulse intensities were calculated from the peak values of the signals by a waveform fitting procedure. This system can measure 10(3)-10(9) photons/pulse of ~10 keV x-rays by direct irradiation of a silicon PIN photodiode, and from 10(7)-10(11) photons/pulse by detecting the x-rays scattered by a diamond film using the silicon PIN photodiode. This system gives a relative accuracy of ~10(-3) with a proper gain setting of the amplifiers for each measurement. Using this system, we succeeded in detecting weak light at the developmental phase of the light source, as well as intense light during lasing of the x-ray free electron laser. © 2012 American Institute of Physics

  12. Determination of crystal structures with large known fragments directly from measured X-ray powder diffraction intensities

    International Nuclear Information System (INIS)

    Rius, J.; Miravitlles, C.

    1988-01-01

    A strategy for the determination of crystal structures with large known fragments directly from measured X-ray powder diffraction intensities is presented. It is based on the automated full-symmetry Patterson search method described by Rius and Miravitlles where the Fourier coefficients of the observed Patterson function are modified to allow the use of powder diffraction intensity data. Its application to two structures, one with simulated and one with experimental data, is shown. (orig.)

  13. Measurement of relative intensities of L-shell X-rays of some heavy elements using Cd-109 radioisotope source

    International Nuclear Information System (INIS)

    Darko, J.B.; Tetteh, G.K.

    1992-01-01

    The relative L-shell x-ray intensities of Sm, W, Ir, Au, Hg, Pb and U were measured using a Cd-109 radioisotope source and a Si(Li) detector. The measured relative intensities were compared with the theoretically calculated values due to Scofield, computed for the present excitation energy of 22.6 keV. The experimental results were found to agree with theory in most cases. (author)

  14. Measurement of relative intensities of L-shell X-rays of some heavy elements using Cd-109 radioisotope source

    Energy Technology Data Exchange (ETDEWEB)

    Darko, J.B.; Tetteh, G.K. (Ghana Univ., Legon (Ghana). Dept. of Physics)

    The relative L-shell x-ray intensities of Sm, W, Ir, Au, Hg, Pb and U were measured using a Cd-109 radioisotope source and a Si(Li) detector. The measured relative intensities were compared with the theoretically calculated values due to Scofield, computed for the present excitation energy of 22.6 keV. The experimental results were found to agree with theory in most cases. (author).

  15. Transient increase in homocysteine but not hyperhomocysteinemia during acute exercise at different intensities in sedentary individuals.

    Directory of Open Access Journals (Sweden)

    Eduardo Iglesias-Gutiérrez

    Full Text Available Considering that hyperhomocysteinemia is an independent risk factor for cardiovascular disease, the purpose of this study was to determine the kinetics of serum homocysteine (tHcy and the vitamins involved in its metabolism (folates, B(12, and B(6 in response to acute exercise at different intensities. Eight sedentary males (18-27 yr took part in the study. Subjects were required to complete two isocaloric (400 kcal acute exercise trials on separate occasions at 40% (low intensity, LI and 80% VO(2peak (high intensity, HI. Blood samples were drawn at different points before (pre4 and pre0 h, during (exer10, exer20, exer30, exer45, and exer60 min, and after exercise (post0, post3, and post19 h. Dietary, genetic, and lifestyle factors were controlled. Maximum tHcy occurred during exercise, both at LI (8.6 (8.0-10.1 µmol/L, 9.3% increase from pre0 and HI (9.4 (8.2-10.6 µmol/L, 25.7% increase from pre0, coinciding with an accumulated energy expenditure independent of the exercise intensity. From this point onwards tHcy declined until the cessation of exercise and continued descending. At post19, tHcy was not different from pre-exercise values. No values of hyperhomocysteinemia were observed at any sampling point and intensity. In conclusion, acute exercise in sedentary individuals, even at HI, shows no negative effect on tHcy when at least 400 kcal are spent during exercise and the nutritional status for folate, B(12, and B(6 is adequate, since no hyperhomocysteinemia has been observed and basal concentrations were recovered in less than 24 h. This could be relevant for further informing healthy exercise recommendations.

  16. Climate variability and increase in intensity and magnitude of dengue incidence in Singapore

    OpenAIRE

    Hii, Yien Ling; Rocklöv, Joacim; Ng, Nawi; Tang, Choon Siang; Pang, Fung Yin; Sauerborn, Rainer

    2009-01-01

    Introduction: Dengue is currently a major public health burden in Asia Pacific Region. This study aims to establish an association between dengue incidence, mean temperature and precipitation and further discuss how weather predictors influence the increase in intensity and magnitude of dengue in Singapore during the period 2000-2007. Materials and methods: Weekly dengue incidence data, daily mean temperature and precipitation and the midyear population data in Singapore during 2000-2007 were...

  17. A high intensity beam line of γ-rays up to 22MeV energy based on Compton backscattering

    International Nuclear Information System (INIS)

    Guo, W.; Xu, W.; Chen, J.G.; Ma, Y.G.; Cai, X.Z.; Wang, H.W.; Xu, Y.; Wang, C.B.; Lu, G.C.; Tian, W.D.; Yuan, R.Y.; Xu, J.Q.; Wei, Z.Y.; Yan, Z.; Shen, W.Q.

    2007-01-01

    Shanghai Laser Electron Gamma Source, a high intensity beam line of γ-ray, has been proposed recently. The beam line is expected to generate γ-rays up to the maximum energy of 22MeV by Compton backscattering between a CO 2 laser and electrons in the 3.5 GeV storage ring of the Shanghai Synchrotron Radiation Facility. The flux of non-collimated γ-rays is estimated to be 10 9 -10 10 s -1 when a CO 2 laser of several hundred Watt power is employed. We will discuss physics issues in the design and optimization of the beam line

  18. Solar cycle dependence of the radial gradient of cosmic ray intensity

    International Nuclear Information System (INIS)

    Allen, J.A.V.

    1988-01-01

    Observation of the interplanetary intensity of cosmic rays (E/sub p/>80 MeV) by Pioneers 10 and 11 now spans a sixteen-year time period 1972--1988 and heliocentric radial distances, r/sub 10/ and r/sub 11/, out to 43.7 AU for Pioneer 10 and 25.8 AU for Pioneer 11. Solar modulation continues to be present at the current distances of both spacecraft. The radial gradient of intensity is measured continuously over the slowly varying, outward moving radial segment Δr = r/sub 10/--r/sub 11/. The 50-day mean values of the gradient G vary systematically and cyclically in phase with solar activity as measured by sunspot number, with a maximum value of about 2.1 percent (AU)/sup -1/ at sunspot maximum and a miminum value of about 1.2 percent (AU)/sup -1/ at sunspot minimum. Thus, the apparent scale size of the heliospheric modulation region as measured by 1/G is about 48 AU at solar max and about 83 AU at solar min: a result that is the inverse of the conjectural inference of Randall and Van Allen [1986] using most of the same body of data but a different analytical point of view. There is persuasive evidence that G is independent of radial distance over the range 2.5 to 34 AU in the mid-point of the segment Δr. No dependence of G on heliographic latitude is evident, but this result does not lend itself to a quantitative statement. copyright American Geophysical Union 1988

  19. Monte Carlo simulation on hard X-ray dose produced in interaction between high intensity laser and solid target

    International Nuclear Information System (INIS)

    Yang Bo; Qiu Rui; Li Junli; Zhang Hui

    2014-01-01

    The X-ray dose produced in the interaction between high intensity laser and solid target was studied by simulation using Monte Carlo code. Compared with experimental results, the calculation model was verified. The calculation model was used to study the effect on X-ray dose with different electron temperatures, target materials (including Au, Cu and PE) and thicknesses. The results indicate that the X-ray dose is mainly determined by the electron temperature, and will be affected by the target parameters. X-ray dose of Au is about 1.2 times that of Cu, and is about 5 times that of PE (polyethylene). In addition, compared with other target thickness, when target thickness is the mean range of electron in the target, X-ray dose is relatively large. These results will provide references on evaluating the ionizing radiation dose for laser devices. (authors)

  20. Measurement of angular distributions of K x-ray intensity of Ti and Cu thick targets following impact of 10–25 keV electrons

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Bhupendra; Kumar, Sunil; Prajapati, Suman; Singh, Bhartendu K. [Atomic Physics Laboratory, Department of Physics, Institute of Science, Banaras Hindu University, Varanasi 221005 (India); Llovet, Xavier [Scientific and Technological Centers, Universitat de Barcelona, Lluís Solé i Sabarís 1-3, 08028 Barcelona (Spain); Shanker, R., E-mail: shankerorama@gmail.com [Atomic Physics Laboratory, Department of Physics, Institute of Science, Banaras Hindu University, Varanasi 221005 (India)

    2017-04-15

    Highlights: • New results on the angular distributions of relative intensities of K-X-rays lines of Ti and Cu thick targets under electron bombardment are reported. • An increase of relative intensity of Kα and Kβ X-ray lines has been found to be about 60–70% in the detection range θ = 105{sup 0}–165{sup 0}. • There is a slight impact energy dependence of Cu Kα X-ray line. • A reasonable agreement between experimental and PENELOPE MC Calculations are obtained. - Abstract: We present new results on angular distributions of the relative intensity of K{sub α} and K{sub β} x-ray lines of thick targets of Ti (Z = 22) and Cu (Z = 29) pure elements following impact of 10–25 keV electrons. The angular measurements of the K x-radiations were accomplished by rotating the target surface with respect to the electron beam direction. The x-rays emerging from the target surface in reflection mode were detected by an energy dispersive Si P-I-N photodiode detector. The resulting variation of the relative intensity of the characteristic lines as a function of angle of detection and impact energy has been found to be anisotropic and it is considered to arise due to change in path lengths at a given incidence angle α for the photons generated by direct as well as by indirect K shell ionization processes. The measured angular variations of relative intensity of K{sub α} and K{sub β} x-ray lines of both targets are found to increase by about 60–70% in going from θ = 105{sup 0} to 165{sup 0} at a given impact energy; however there is a slight indication of impact energy dependence of Cu K{sub α} x-ray line as also noted by the earlier workers. We compare the experimental results with those obtained by Monte Carlo simulations using PENELOPE calculations; the agreement between experiment and theory is found to be satisfactory within uncertainties involved in the measurements and the theoretical results.

  1. Correction factors for {gamma}-ray relative intensities in the {sup 66}Ga radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, G.J. [Duke Univ., Durham, NC (United States)]|[Triangle Universities Nuclear Lab., Durham, NC (United States); Chasteler, R.M. [Duke Univ., Durham, NC (United States)]|[Triangle Universities Nuclear Lab., Durham, NC (United States); Laymon, C.M. [Duke Univ., Durham, NC (United States)]|[Triangle Universities Nuclear Lab., Durham, NC (United States); Weller, H.R. [Duke Univ., Durham, NC (United States)]|[Triangle Universities Nuclear Lab., Durham, NC (United States); Moore, E.F. [Triangle Universities Nuclear Lab., Durham, NC (United States)]|[North Carolina State Univ., Raleigh, NC (United States); Bybee, C.R. [Triangle Universities Nuclear Lab., Durham, NC (United States)]|[North Carolina State Univ., Raleigh, NC (United States); Drake, J.M. [Triangle Universities Nuclear Lab., Durham, NC (United States)]|[North Carolina State Univ., Raleigh, NC (United States); Tilley, D.R. [Triangle Universities Nuclear Lab., Durham, NC (United States)]|[North Carolina State Univ., Raleigh, NC (United States); Vavrina, G. [Triangle Universities Nuclear Lab., Durham, NC (United States)]|[North Carolina State Univ., Raleigh, NC (United States); Wallace, P.M. [Triangle Universities Nuclear Lab., Durham, NC (United States)]|[North Carolina State Univ., Raleigh, NC (United States)

    1996-09-16

    We present here strong evidence that recently published values for the relative intensities of {gamma}-ray lines in the {sup 66}Ga({beta}{sup +}+EC){sup 66}Zn decay are incorrect at the higher energies ({proportional_to}30% too low at 4.8 MeV). In particular, we find that our current results are consistent with a set of correction factors which were first suggested 20 years ago, but have gone largely ignored until now. Our validation of these little known correction factors will have bearing on experiments which use the {sup 66}Ga radioisotope to extrapolate absolute detector efficiencies to higher energies. In particular, we discuss the conclusions of a recent D(p, {gamma}){sup 3}He experiment which will be strongly affected by our current results. The astrophysical S-factor data derived from this D(p, {gamma}){sup 3}He experiment are now seen to be systematically too low by {proportional_to}30%. (orig.).

  2. Climate variability and increase in intensity and magnitude of dengue incidence in Singapore.

    Science.gov (United States)

    Hii, Yien Ling; Rocklöv, Joacim; Ng, Nawi; Tang, Choon Siang; Pang, Fung Yin; Sauerborn, Rainer

    2009-11-11

    Dengue is currently a major public health burden in Asia Pacific Region. This study aims to establish an association between dengue incidence, mean temperature and precipitation, and further discuss how weather predictors influence the increase in intensity and magnitude of dengue in Singapore during the period 2000-2007. Weekly dengue incidence data, daily mean temperature and precipitation and the midyear population data in Singapore during 2000-2007 were retrieved and analysed. We employed a time series Poisson regression model including time factors such as time trends, lagged terms of weather predictors, considered autocorrelation, and accounted for changes in population size by offsetting. The weekly mean temperature and cumulative precipitation were statistically significant related to the increases of dengue incidence in Singapore. Our findings showed that dengue incidence increased linearly at time lag of 5-16 and 5-20 weeks succeeding elevated temperature and precipitation, respectively. However, negative association occurred at lag week 17-20 with low weekly mean temperature as well as lag week 1-4 and 17-20 with low cumulative precipitation. As Singapore experienced higher weekly mean temperature and cumulative precipitation in the years 2004-2007, our results signified hazardous impacts of climate factors on the increase in intensity and magnitude of dengue cases. The ongoing global climate change might potentially increase the burden of dengue fever infection in near future.

  3. On the multiphoton emission during U.V. and X-ray absorption by atoms in intense laser fields

    International Nuclear Information System (INIS)

    Miranda, L.C.M.

    1981-09-01

    A discussion of the u.v. and x-ray absorption cross section by a hydrogen atom in the presence of an intense i.r. laser field is presented, taking into account the influence of laser field on the electronic states. (Author) [pt

  4. Blood lipid peroxides and muscle damage increased following intensive resistance training of female weightlifters.

    Science.gov (United States)

    Liu, Jen-Fang; Chang, Wei-Yin; Chan, Kuei-Hui; Tsai, Wen-Yee; Lin, Chen-Li; Hsu, Mei-Chieh

    2005-05-01

    The aim of this study was to examine changes in muscle cell injury and antioxidant capacity of weightlifters following a 1-week intensive resistance-training regimen. Thirty-six female subjects participated in this study, and their ages ranged from 18 to 25 years. The sample group included 19 elite weightlifters with more than 3 years of weightlifting training experience, while the control group comprised 17 non-athletic individuals. Compared with non-athletes, weightlifters had significantly lower glutathione peroxidase activity and plasma vitamin C concentrations. Weightlifters also had significantly higher malondialdehyde + 4-hydroxy 2-(E)-nonenal (MDA+4-HNE) and thiobarbituric acid-reactive substance (TBARS) levels and creatine kinase (CK) activity. For weightlifters, the plasma vitamin E level and the activity of superoxide dismutase (SOD) decreased, and CK activity increased significantly (P weightlifters (P injury in female weightlifters. Furthermore, proper rest after intensive training was found to be important for recovery.

  5. Measurement of relative intensities of L-shell x-rays in some high-Z elements

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S; Mittal, R; Allawadhi, K L; Sood, B S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1982-10-14

    The L-shell x-ray relative intensities I(Lsub(..cap alpha..))/I(Lsub(l)),I(Lsub(..cap alpha..))/I(Lsub(..beta..)) and I(Lsub(..cap alpha..))/I(Lsub(..gamma..)) for U, Th, Pb and ratios I(Lsub(..cap alpha..+l))/I(Lsub(..beta..)) and I(Lsub(..cap alpha..+l))/I(Lsub(..gamma..)) for W have been measured. The L-shell electrons are excited by 59.57 keV gamma rays from /sup 241/Am and the fluorescent L-shell x-ray intensities are measured with a Si(Li) detector. The experimental results are found to agree well with theory.

  6. Theoretical analysis of the background intensity distribution in X-ray Birefringence Imaging using synchrotron bending-magnet radiation

    Science.gov (United States)

    Sutter, John P.; Dolbnya, Igor P.; Collins, Stephen P.; Harris, Kenneth D. M.; Edwards-Gau, Gregory R.; Palmer, Benjamin A.

    2015-04-01

    In the recently developed technique of X-ray Birefringence Imaging, molecular orientational order in anisotropic materials is studied by exploiting the birefringence of linearly polarized X-rays with energy close to an absorption edge of an element in the material. In the experimental setup, a vertically deflecting high-resolution double-crystal monochromator is used upstream from the sample to select the appropriate photon energy, and a horizontally deflecting X-ray polarization analyzer, consisting of a perfect single crystal with a Bragg reflection at Bragg angle of approximately 45°, is placed downstream from the sample to measure the resulting rotation of the X-ray polarization. However, if the experiment is performed on a synchrotron bending-magnet beamline, then the elliptical polarization of the X-rays out of the electron orbit plane affects the shape of the output beam. Also, because the monochromator introduces a correlation between vertical position and photon energy to the X-ray beam, the polarization analyzer does not select the entire beam, but instead selects a diagonal stripe, the slope of which depends on the Bragg angles of the monochromator and the polarization analyzer. In the present work, the final background intensity distribution is calculated analytically because the phase space sampling methods normally used in ray traces are too inefficient for this setup. X-ray Birefringence Imaging data measured at the Diamond Light Source beamline B16 agree well with the theory developed here.

  7. Theoretical analysis of the background intensity distribution in X-ray Birefringence Imaging using synchrotron bending-magnet radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, John P., E-mail: john.sutter@diamond.ac.uk; Dolbnya, Igor P.; Collins, Stephen P. [Diamond Light Source Ltd., Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); Harris, Kenneth D. M.; Edwards-Gau, Gregory R. [School of Chemistry, Cardiff University, Park Place, Cardiff CF10 3AT, Wales (United Kingdom); Palmer, Benjamin A. [Department of Structural Biology, Weizmann Institute of Science, 234 Herzl St., Rehovot 7610001 (Israel)

    2015-04-28

    In the recently developed technique of X-ray Birefringence Imaging, molecular orientational order in anisotropic materials is studied by exploiting the birefringence of linearly polarized X-rays with energy close to an absorption edge of an element in the material. In the experimental setup, a vertically deflecting high-resolution double-crystal monochromator is used upstream from the sample to select the appropriate photon energy, and a horizontally deflecting X-ray polarization analyzer, consisting of a perfect single crystal with a Bragg reflection at Bragg angle of approximately 45°, is placed downstream from the sample to measure the resulting rotation of the X-ray polarization. However, if the experiment is performed on a synchrotron bending-magnet beamline, then the elliptical polarization of the X-rays out of the electron orbit plane affects the shape of the output beam. Also, because the monochromator introduces a correlation between vertical position and photon energy to the X-ray beam, the polarization analyzer does not select the entire beam, but instead selects a diagonal stripe, the slope of which depends on the Bragg angles of the monochromator and the polarization analyzer. In the present work, the final background intensity distribution is calculated analytically because the phase space sampling methods normally used in ray traces are too inefficient for this setup. X-ray Birefringence Imaging data measured at the Diamond Light Source beamline B16 agree well with the theory developed here.

  8. Improved Symmetry Greatly Increases X-Ray Power from Wire-Array Z-Pinches

    International Nuclear Information System (INIS)

    Sanford, T.W.; Allshouse, G.O.; Marder, B.M.; Nash, T.J.; Mock, R.C.; Spielman, R.B.; Seamen, J.F.; McGurn, J.S.; Jobe, D.; Gilliland, T.L.; Vargas, M.; Struve, K.W.; Stygar, W.A.; Douglas, M.R.; Matzen, M.K.; Hammer, J.H.; De Groot, J.S.; Eddleman, J.L.; Peterson, D.L.; Mosher, D.; Whitney, K.G.; Thornhill, J.W.; Pulsifer, P.E.; Apruzese, J.P.; Maron, Y.

    1996-01-01

    A systematic experimental study of annular aluminum-wire Z-pinches on a 20-TW electrical generator shows that the measured spatial characteristics and emitted x-ray power agree more closely with rad-hydro simulations when large numbers of wires are used. The measured x-ray power increases first slowly and then rapidly with decreasing interwire gap spacing. Simulations suggested that this increase reflects the transition from implosion of individual wire plasmas to one of an azimuthally symmetric plasma shell. In the plasma-shell regime, x-ray powers of 40TW are achieved. copyright 1996 The American Physical Society

  9. Increasing upper limb training intensity in chronic stroke using embodied virtual reality: a pilot study.

    Science.gov (United States)

    Perez-Marcos, Daniel; Chevalley, Odile; Schmidlin, Thomas; Garipelli, Gangadhar; Serino, Andrea; Vuadens, Philippe; Tadi, Tej; Blanke, Olaf; Millán, José D R

    2017-11-17

    Technology-mediated neurorehabilitation is suggested to enhance training intensity and therefore functional gains. Here, we used a novel virtual reality (VR) system for task-specific upper extremity training after stroke. The system offers interactive exercises integrating motor priming techniques and embodied visuomotor feedback. In this pilot study, we examined (i) rehabilitation dose and training intensity, (ii) functional improvements, and (iii) safety and tolerance when exposed to intensive VR rehabilitation. Ten outpatient stroke survivors with chronic (>6 months) upper extremity paresis participated in a ten-session VR-based upper limb rehabilitation program (2 sessions/week). All participants completed all sessions of the treatment. In total, they received a median of 403 min of upper limb therapy, with 290 min of effective training. Within that time, participants performed a median of 4713 goal-directed movements. Importantly, training intensity increased progressively across sessions from 13.2 to 17.3 movements per minute. Clinical measures show that despite being in the chronic phase, where recovery potential is thought to be limited, participants showed a median improvement rate of 5.3% in motor function (Fugl-Meyer Assessment for Upper Extremity; FMA-UE) post intervention compared to baseline, and of 15.4% at one-month follow-up. For three of them, this improvement was clinically significant. A significant improvement in shoulder active range of motion (AROM) was also observed at follow-up. Participants reported very low levels of pain, stress and fatigue following each session of training, indicating that the intensive VR intervention was well tolerated. No severe adverse events were reported. All participants expressed their interest in continuing the intervention at the hospital or even at home, suggesting high levels of adherence and motivation for the provided intervention. This pilot study showed how a dedicated VR system could deliver high

  10. Photoneutron intensity variation with field size around radiotherapy linear accelerator 18-MeV X-ray beam

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ghamdi, H.; Fazal-ur-Rehman [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Jarallah, M.I. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: mibrahim@kfupm.edu.sa; Maalej, N. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2008-08-15

    In X-ray radiotherapy accelerators, neutrons are produced mainly by ({gamma},n) reaction when high energy X-rays interact with high Z materials of the linear accelerator head. These materials include the lead (Pb) used as shielding in the collimator, tungsten (W) target used for the production of X-rays and iron (Fe) in the accelerator head. These unwanted neutrons contaminate the therapeutic beam and contribute to the patient dose during the treatment of a cancer patient. Knowing the neutron distribution around the radiotherapy accelerator is therefore desired. CR-39 nuclear track detectors (NTDs) were used to study the variation of fast and thermal neutron relative intensities around an 18 MeV linear accelerator X-ray beam with the field sizes of 0, 10x10, 20x20, 30x30 and 40x40cm{sup 2}. For fast neutron detection, bare NTDs were used. For thermal neutron detection, NTDs were covered with lithium tetra borate (Li{sub 2}B{sub 4}O{sub 7}) converters. The NTDs were placed at different locations in the direction perpendicular to the treatment couch (transversal) and in the direction parallel to the treatment couch (longitudinal) with respect to the isocenter of the accelerator. The fast neutron relative intensity is symmetrical about the beam axis and exhibits an exponential-like drop with distance from the isocenter of the accelerator for all the field sizes. At the primary beam (isocenter), the relative fast neutron intensity is highest for 40x40cm{sup 2} field size and decreases linearly with the decrease in the field size. However, fast neutron intensities do not change significantly with beam size for the measurements outside the primary beam. The fast neutron intensity in the longitudinal direction outside the primary beam decreases linearly with the field size. The thermal neutron intensity, at any location, was found to be almost independent of the field size.

  11. Randomized Controlled Trial of Social Media: Effect of Increased Intensity of the Intervention.

    Science.gov (United States)

    Fox, Caroline S; Gurary, Ellen B; Ryan, John; Bonaca, Marc; Barry, Karen; Loscalzo, Joseph; Massaro, Joseph

    2016-04-27

    A prior randomized controlled trial of social media exposure at Circulation determined that social media did not increase 30-day page views. Whether insufficient social media intensity contributed to these results is uncertain. Original article manuscripts were randomized to social media exposure compared with no social media exposure (control) at Circulation beginning in January 2015. Social media exposure consisted of Facebook and Twitter posts on the journal's accounts. To increase social media intensity, a larger base of followers was built using advertising and organic growth, and posts were presented in triplicate and boosted on Facebook and retweeted on Twitter. The primary outcome was 30-day page views. Stopping rules were established at the point that 50% of the manuscripts were randomized and had 30-day follow-up to compare groups on 30-day page views. The trial was stopped for futility on September 26, 2015. Overall, 74 manuscripts were randomized to receive social media exposure, and 78 manuscripts were randomized to the control arm. The intervention and control arms were similar based on article type (P=0.85), geographic location of the corresponding author (P=0.33), and whether the manuscript had an editorial (P=0.80). Median number of 30-day page views was 499.5 in the social media arm and 450.5 in the control arm; there was no evidence of a treatment effect (P=0.38). There were no statistically significant interactions of treatment by manuscript type (P=0.86), by corresponding author (P=0.35), by trimester of publication date (P=0.34), or by editorial status (P=0.79). A more intensive social media strategy did not result in increased 30-day page views of original research. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  12. Characterization of increased persistence and intensity of precipitation in the northeastern United States

    Science.gov (United States)

    Guilbert, Justin; Betts, Alan K.; Rizzo, Donna M.; Beckage, Brian; Bomblies, Arne

    2015-03-01

    We present evidence of increasing persistence in daily precipitation in the northeastern United States that suggests that global circulation changes are affecting regional precipitation patterns. Meteorological data from 222 stations in 10 northeastern states are analyzed using Markov chain parameter estimates to demonstrate that a significant mode of precipitation variability is the persistence of precipitation events. We find that the largest region-wide trend in wet persistence (i.e., the probability of precipitation in 1 day and given precipitation in the preceding day) occurs in June (+0.9% probability per decade over all stations). We also find that the study region is experiencing an increase in the magnitude of high-intensity precipitation events. The largest increases in the 95th percentile of daily precipitation occurred in April with a trend of +0.7 mm/d/decade. We discuss the implications of the observed precipitation signals for watershed hydrology and flood risk.

  13. Impact of intense x-ray pulses on a NaI(Tl)-based gamma camera

    NARCIS (Netherlands)

    Koppert, Wilco J C; van der Velden, Sandra; Steenbergen, J H Leo; de Jong, Hugo W A M

    2018-01-01

    INTRODUCTION: In SPECT/CT systems X-ray and -ray imaging is performed sequentially. Simultaneous acquisition may have advantages, for instance in interventional settings. However, this may expose a gamma camera to relatively high X-ray doses and deteriorate its functioning. We studied the NaI(Tl)

  14. L X-ray energy shifts and intensity ratios in tantalum with C and N ions

    Indian Academy of Sciences (India)

    charged particles. Study of atomic ... authors [1–10] have observed that the X-ray energy shifts in heavy ion collision process are relative to the ... and observed the L X-ray energy shifts of different L X-ray components in some high Z elements.

  15. Registration of intensive hard X-rays and soft gamma-rays from the thunderstorm clouds at Tien-Shan installation Adron

    International Nuclear Information System (INIS)

    Antonova, V.P.; Kryukov, S.V.; Vil'danova, L.I.; Gurevich, A.V.; Zybin, K.P.; Kokobaev, M.M.; Nesterova, N.M.; Piskal', V.V.; Ptitsyn, M.O.; Chubenko, A.P.; Shchepetov, A.L.

    2001-01-01

    The Adron installation mounted at the Tien-Shan station is intended for studying the extensive air showers. The Adron installation consists of a neutron supermonitor charged particles detector, muon detector and detector for registering the hard X-ray and soft gamma-radiation from the thunderstorm clouds accomplished on the basis of the Geiger-Mueller counters with sensitivity area of 16-17 m 2 . The intensive fluxes of the hard X-ray and soft gamma-radiation from the thunderstorm clouds passing over the Adron installation at the height below 1 km are registered using this installation. The short-time radiation flares of 1-5 min duration are separated at the background of the intensity slow change. This testifies to the benefit of existence of the runaway electron effect in the thunderstorm clouds [ru

  16. Quantitative x-ray absorption imaging with a broadband source: application to high-intensity discharge lamps

    Energy Technology Data Exchange (ETDEWEB)

    Curry, J J [National Institute of Standards and Technology, Gaithersburg, MD 20899-8422 (United States)], E-mail: jjcurry@nist.gov

    2008-07-21

    The case of x-ray absorption imaging in which the x-ray source is broadband and the detector does not provide spectral resolution is analysed. The specific motivation is observation of the Hg vapour distribution in high-intensity discharge (HID) lamps. When absorption by the vapour is small, the problem can be couched accurately in terms of a mean absorption cross section averaged over the x-ray spectral distribution, weighted by the energy-dependent response of the detector. The method is tested against a Au foil standard and then applied to Hg. The mean absorption cross section for Hg is calculated for a Ag-anode x-ray tube at accelerating voltages of 25, 30 and 35 kV, and for HIDs in fused silica or polycrystalline alumina arc tubes.

  17. High-intensity X-rays interaction with matter processes in plasmas, clusters, molecules and solids

    CERN Document Server

    Hau-Riege, Stefan P

    2012-01-01

    Filling the need for a book bridging the effect of matter on X-ray radiation and the interaction of x-rays with plasmas, this monograph provides comprehensive coverage of the topic. As such, it presents and explains such powerful new X-ray sources as X-ray free-electron lasers, as well as short pulse interactions with solids, clusters, molecules, and plasmas, and X-ray matter interactions as a diagnostic tool. Equally useful for researchers and practitioners working in the field.

  18. Observation of intensity of cosmic rays and daily magnetic shifts near meridian 70° in the South America

    Science.gov (United States)

    Cordaro, E. G.; Gálvez, D.; Laroze, D.

    2016-05-01

    In analysis of experiments carried during September 2008 using secondary cosmic ray detectors located in Chacaltaya (Bolivia) and Niteroi (Brazil), Augusto et al. (2010) showed an increase in the intensity of charged particles which takes place 3 h after sunrise and lasts until 1 h after sunset, furthermore they said that during this period the solar magnetic field lines overtake the Earth‧s surface. These stations are located within the South Atlantic Magnetic Anomaly (SAMA), having both different magnetic rigidities. To reproduce data from the Niteroi and Chacaltaya stations, we record data during the same hours and days using our neutron monitors, muon telescopes and magnetometers within the stations Putre and Los Cerrillos. Our observation stations in Putre and Cerrillos are located at 18°11‧47.8″S, 69°33‧10.9″W at an altitude of 3600 m and 33°29‧42.3″S, 70°42‧59.81″W with 570 m height above sea level, respectively. These stations are located within the South Atlantic Anomaly (SAMA) and are separated approximately 1700 km from each other and 1700 km from the center of the anomaly. Our network is composed furthermore by two auxiliary Cosmic Ray and/or Geomagnetic stations located at different latitudes along 70°W meridian, LARC and O'Higgins stations, which are located within Antarctic territory, covering a broad part of the Southern Hemisphere. Our magnetometer data shows that for each of the components, shifts in the magnetic field intensity for every station (even for those out of the SAMA) lasted between 3 and 4 h after sunrise and 1 and 2 h past sunset, which are the periods when the geomagnetic field is modulated by the transit of the dayside to nightside and nightside to dayside. We believe that, although the magnetometric data indicates the magnetic reconnection for the Chilean region, there is no direct influence from the SAMA other than the lower rigidity cut-off that leads to an increased count rate. Other details about the

  19. Energy and CKT dependence of proton induced L subshell X-ray intensity ratios in elements 57≤Z≤92

    International Nuclear Information System (INIS)

    Thakkar, Rohit; Sharma, Babita; Allawadhi, K.L.

    2006-01-01

    The dependence of L subshell X-ray intensity ratios on incident proton energy and the CK transitions has been investigated in elements 57≤Z≤92. The intensity ratio I(L α )/I(L l ) neither shows variation with energy nor any dependence on the CK transitions. In general, the ratios I(L α )/I(L β ) and I(L α )/I(L γ ), first increase with incident proton energy, attain a maximum value, then start decreasing and attain an almost constant value after a particular energy (ranging from about 4.6 MeV for La to 5.8 MeV for U). A comparison has been made among the intensity ratios evaluated using three different sets of parameters. A maximum difference of about 18% has been observed among the different values

  20. Globally Increased Crop Growth and Cropping Intensity from the Long-Term Satellite-Based Observations

    Science.gov (United States)

    Chen, Bin

    2018-04-01

    Understanding the spatiotemporal change trend of global crop growth and multiple cropping system under climate change scenarios is a critical requirement for supporting the food security issue that maintains the function of human society. Many studies have predicted the effects of climate changes on crop production using a combination of filed studies and models, but there has been limited evidence relating decadal-scale climate change to global crop growth and the spatiotemporal distribution of multiple cropping system. Using long-term satellite-derived Normalized Difference Vegetation Index (NDVI) and observed climate data from 1982 to 2012, we investigated the crop growth trend, spatiotemporal pattern trend of agricultural cropping intensity, and their potential correlations with respect to the climate change drivers at a global scale. Results show that 82.97 % of global cropland maximum NDVI witnesses an increased trend while 17.03 % of that shows a decreased trend over the past three decades. The spatial distribution of multiple cropping system is observed to expand from lower latitude to higher latitude, and the increased cropping intensity is also witnessed globally. In terms of regional major crop zones, results show that all nine selected zones have an obvious upward trend of crop maximum NDVI (p impact on the crop growth trend.

  1. GLOBALLY INCREASED CROP GROWTH AND CROPPING INTENSITY FROM THE LONG-TERM SATELLITE-BASED OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    B. Chen

    2018-04-01

    Full Text Available Understanding the spatiotemporal change trend of global crop growth and multiple cropping system under climate change scenarios is a critical requirement for supporting the food security issue that maintains the function of human society. Many studies have predicted the effects of climate changes on crop production using a combination of filed studies and models, but there has been limited evidence relating decadal-scale climate change to global crop growth and the spatiotemporal distribution of multiple cropping system. Using long-term satellite-derived Normalized Difference Vegetation Index (NDVI and observed climate data from 1982 to 2012, we investigated the crop growth trend, spatiotemporal pattern trend of agricultural cropping intensity, and their potential correlations with respect to the climate change drivers at a global scale. Results show that 82.97 % of global cropland maximum NDVI witnesses an increased trend while 17.03 % of that shows a decreased trend over the past three decades. The spatial distribution of multiple cropping system is observed to expand from lower latitude to higher latitude, and the increased cropping intensity is also witnessed globally. In terms of regional major crop zones, results show that all nine selected zones have an obvious upward trend of crop maximum NDVI (p < 0.001, and as for climatic drivers, the gradual temperature and precipitation changes have had a measurable impact on the crop growth trend.

  2. Fluctuations on the X-ray intensity beam using a portable X-ray probe based on {sup 6}LiI(Eu) crystal

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Geraldo P.; Oliveira, Arno H. [Universidade Federal de Minas Gerais (PCTN/UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares; Carneiro, Andre C.; Carneiro, Clemente J.G.; Milian, Felix M.; Velasco, Fermin G., E-mail: fermin@uesc.b [Universidade Estadual de Santa Cruz (CPqCTR/UESC), Ilheus, BA (Brazil). Centro de Pesquisa em Ciencias e Tecnologias das Radiacoes

    2011-07-01

    X-rays are produced by accelerating electrons with a high voltage and allowing them to collide with a metal target. This high voltage presents fluctuations that define peak, minimum, and average voltages. Different voltages are applied to the X-ray tube depending on the radiographic applications. A rectifier circuit converts the alternating high voltage to unidirectional high voltage to accelerate electrons in this tube. The fluctuations on the energy in the electron beam depend on the mode of rectification. Both energy of the electrons and X rays intensity fluctuates. A portable probe built with a {sup 6}LiI(Eu) detector coupled to a 10 m light guide and a Hamamatsu photon counting head H9319 was used to measuring X ray intensities. This system is designed to collect up to 10000 counts in intervals of 10 ms to 1 s. Counts were accumulated in time intervals of 10 ms during 10 s. The system starts the count before activating the X-ray apparatus, which is on during a time interval of 100ms. During this period, counts may overflow in consequence high voltage was adjusted to be 40kV, in order to avoid such a problem. For each of these points dose was measured using an ionization chamber. The objectives of this work are to study fluctuations on the X-ray beam and to calibrate the portable probe for measuring radiation doses. Counting rates measured for each 10 ms presented strong variations due to high voltages fluctuations. Both dose and counting rate when correlated with distances between source and detector followed the inverse square law and presented values of R2 near of unit. A calibration curve of the portable system for dose measurements showed also R2 value near of unity. (author)

  3. Intense Non-Linear Soft X-Ray Emission from a Hydride Target during Pulsed D Bombardment

    Science.gov (United States)

    Miley, George H.; Yang, Yang; Lipson, Andrei; Haque, Munima; Percel, Ian; Romer, Michael

    Radiation emission from low-energy nuclear radiation (LENR) electrodes (both charged-particle and X-rays) represents an important feature of LENR in general. Here, calibration, measurement techniques, and soft X-ray emission results from deuterium bombardment of a Pd target (cathode) placed in a pulsed deuterium glow discharge (PGD) are described. An X-ray intensity of 13.4 mW/cm2 and a dose of 3.3 μJ/cm2 were calculated over a 0.5 ms pulse time from AXUV photodiode radiation detector measurements. A most striking feature is that X-ray energies >600 V are observed with a discharge voltage only about half of that value. To further investigate this phenomenon, emission during room temperature D-desorption from electrolytically loaded Pd:Dx cathodes was also studied. The X-ray emission energy observed was quite similar to the PGD case. However, the intensity in this case was almost 13 orders of magnitude lower due to the much lower deuterium fluxes involved.

  4. Intense non-linear soft X-ray emission from a hydride target during pulsed D bombardment

    International Nuclear Information System (INIS)

    Miley, George H.; Yang, Yang; Lipson, Andrei; Haque, Munima; Percel, Ian; Romer, Michael

    2006-01-01

    Radiation emission from low-energy nuclear radiation (LENR) electrodes (both charged-particle and X-rays) represents an important feature of LENR in general. Here, calibration, measurement techniques, and soft X-ray emission results from deuterium bombardment of a Pd target (cathode) placed in a pulsed deuterium glow discharge (PGD) are described. An X-ray intensity of 13.4 mW/cm 2 and a dose of 3.3 μJ/cm 2 were calculated over a 0.5 ms pulse time from AXUV photodiode radiation detector measurements. A most striking feature is that X-ray energies >600 V are observed with a discharge voltage only about half of that value. To further investigate this phenomenon, emission during room temperature D-desorption from electrolytically loaded Pd:Dx cathodes was also studied. The X-ray emission energy observed was quite similar to the PGD case. However, the intensity in this case was almost 13 orders of magnitude lower due to the much lower deuterium fluxes involved. (author)

  5. AN XMM-NEWTON SURVEY OF THE SOFT X-RAY BACKGROUND. II. AN ALL-SKY CATALOG OF DIFFUSE O VII AND O VIII EMISSION INTENSITIES

    International Nuclear Information System (INIS)

    Henley, David B.; Shelton, Robin L.

    2012-01-01

    We present an all-sky catalog of diffuse O VII and O VIII line intensities, extracted from archival XMM-Newton observations. This catalog supersedes our previous catalog, which covered the sky between l = 120° and l = 240°. We attempted to reduce the contamination from near-Earth solar wind charge exchange (SWCX) emission by excluding times of high solar wind proton flux from the data. Without this filtering, we were able to extract measurements from 1868 observations. With this filtering, nearly half of the observations became unusable, and only 1003 observations yielded measurements. The O VII and O VIII intensities are typically ∼2-11 and ∼ –2 s –1 sr –1 (line unit, L.U.), respectively, although much brighter intensities were also recorded. Our data set includes 217 directions that have been observed multiple times by XMM-Newton. The time variation of the intensities from such directions may be used to constrain SWCX models. The O VII and O VIII intensities typically vary by ∼ 10 L.U. were observed. We compared our measurements with models of the heliospheric and geocoronal SWCX. The heliospheric SWCX intensity is expected to vary with ecliptic latitude and solar cycle. We found that the observed oxygen intensities generally decrease from solar maximum to solar minimum, both at high ecliptic latitudes (which is as expected) and at low ecliptic latitudes (which is not as expected). The geocoronal SWCX intensity is expected to depend on the solar wind proton flux incident on the Earth and on the sightline's path through the magnetosheath. The intensity variations seen in directions that have been observed multiple times are in poor agreement with the predictions of a geocoronal SWCX model. We found that the oxygen lines account for ∼40%-50% of the 3/4 keV X-ray background that is not due to unresolved active galactic nuclei, in good agreement with a previous measurement. However, we found that this fraction is not easily explainable by a

  6. SSRI treatment suppresses dream recall frequency but increases subjective dream intensity in normal subjects.

    Science.gov (United States)

    Pace-Schott, E F; Gersh, T; Silvestri, R; Stickgold, R; Salzman, C; Hobson, J A

    2001-06-01

    Clinical lore and a small number of published studies report that the selective serotonin reuptake inhibitors (SSRIs) intensify dreaming. This study examines the dream effects of paroxetine and fluvoxamine in order to both increase clinical knowledge of these agents and to test an important potential method for probing the relationship between REM sleep neurobiology and dreaming in humans. Fourteen normal, paid volunteers (4 males, 10 females; mean age 27.4 year, range 22--39) free of medical or neuropsychiatric symptoms as well as of psychotropic or sleep affecting drugs completed a 31-day home-based study consisting of: 7 days drug-free baseline; 19 days on either 100 mg fluvoxamine (7 Ss) or 20 mg paroxetine (7 Ss) in divided morning and evening doses; and 5 days acute discontinuation. Upon awakening, subjects wrote dream reports, self-scored specific emotions in their reports and rated seven general dream characteristics using 5-point Likert scales. Dream reports were independently scored for bizarreness, movement and number of visual nouns by three judges. REM sleep-related measures were obtained using the Nightcap ambulatory sleep monitor. Mean dream recall frequency decreased during treatment compared with baseline. Dream report length and judge-rated bizarreness were greater during acute discontinuation compared with both baseline and treatment and this effect was a result of the fluvoxamine-treated subjects. The subjective intensity of dreaming increased during both treatment and acute discontinuation compared with baseline. Propensity to enter REM sleep was decreased during treatment compared with baseline and acute discontinuation and the intensity of REM sleep increased during acute discontinuation compared with baseline and treatment. The decrease in dream frequency during SSRI treatment may reflect serotonergic REM suppression while the augmented report length and bizarreness during acute SSRI discontinuation may reflect cholinergic rebound from

  7. Increasing communication in the intensive care unit: is blogging the answer?

    Science.gov (United States)

    Curry, Kimberly

    2012-01-01

    Effective communication is a key factor to success in intensive care nursing. At Allegheny General Hospital in Pittsburgh, Pennsylvania, a cardiac intensive care unit (ICU) incorporated blogging as one of its primary means of communication. In the health care clinical environment, blogging can help to promote 2-way communication among nursing staff and leadership. Blogging can serve as a valuable method of relaying important updates, changes in practice, and educational resources. Incorporating a blog into the ICU environment involves a cultural shift and some potential barriers. Lack of a technological understanding of social media, outdated software systems, and limited hospital policies may pose issues when incorporating a blog into the health care setting. The benefits though are impressive. Blogging is a form of rapid, real-time communication for which any person may post or comment on an important thought or message. Blogging can help to increase compliance with quality measures, update staff on need to know information such as changes in policies and procedures, and provide up-to-date educational resources at any time, from anywhere.

  8. Microjet formation and hard x-ray production from a liquid metal target irradiated by intense femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Lar' kin, A., E-mail: alexeylarkin@yandex.ru; Uryupina, D.; Ivanov, K.; Savel' ev, A., E-mail: abst@physics.msu.ru [International Laser Center and Faculty of Physics, Lomonosov Moscow State University, Moscow 119991 (Russian Federation); Bonnet, T.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M. [Centre d' Études Nucléaires de Bordeaux-Gradignan, University of Bordeaux-CNRS-IN2P3, 33170 Gradignan (France); Spohr, K. [School of Engineering, University of the West of Scotland, Paisley, Scotland PA1 2BE (United Kingdom); Breil, J.; Chimier, B.; Dorchies, F.; Fourment, C.; Leguay, P.-M.; Tikhonchuk, V. T. [Centre Lasers Intenses et Applications, University of Bordeaux-CNRS-CEA, Talence 33405 (France)

    2014-09-15

    By using a liquid metal as a target one may significantly enhance the yield of hard x-rays with a sequence of two intense femtosecond laser pulses. The influence of the time delay between the two pulses is studied experimentally and interpreted with numerical simulations. It was suggested that the first arbitrary weak pulse produces microjets from the target surface, while the second intense pulse provides an efficient electron heating and acceleration along the jet surface. These energetic electrons are the source of x-ray emission while striking the target surface. The microjet formation is explained based on the results given by both optical diagnostics and hydrodynamic modeling by a collision of shocks originated from two distinct zones of laser energy deposition.

  9. Microjet formation and hard x-ray production from a liquid metal target irradiated by intense femtosecond laser pulses

    International Nuclear Information System (INIS)

    Lar'kin, A.; Uryupina, D.; Ivanov, K.; Savel'ev, A.; Bonnet, T.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M.; Spohr, K.; Breil, J.; Chimier, B.; Dorchies, F.; Fourment, C.; Leguay, P.-M.; Tikhonchuk, V. T.

    2014-01-01

    By using a liquid metal as a target one may significantly enhance the yield of hard x-rays with a sequence of two intense femtosecond laser pulses. The influence of the time delay between the two pulses is studied experimentally and interpreted with numerical simulations. It was suggested that the first arbitrary weak pulse produces microjets from the target surface, while the second intense pulse provides an efficient electron heating and acceleration along the jet surface. These energetic electrons are the source of x-ray emission while striking the target surface. The microjet formation is explained based on the results given by both optical diagnostics and hydrodynamic modeling by a collision of shocks originated from two distinct zones of laser energy deposition

  10. Microjet formation and hard x-ray production from a liquid metal target irradiated by intense femtosecond laser pulses

    Science.gov (United States)

    Lar'kin, A.; Uryupina, D.; Ivanov, K.; Savel'ev, A.; Bonnet, T.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M.; Spohr, K.; Breil, J.; Chimier, B.; Dorchies, F.; Fourment, C.; Leguay, P.-M.; Tikhonchuk, V. T.

    2014-09-01

    By using a liquid metal as a target one may significantly enhance the yield of hard x-rays with a sequence of two intense femtosecond laser pulses. The influence of the time delay between the two pulses is studied experimentally and interpreted with numerical simulations. It was suggested that the first arbitrary weak pulse produces microjets from the target surface, while the second intense pulse provides an efficient electron heating and acceleration along the jet surface. These energetic electrons are the source of x-ray emission while striking the target surface. The microjet formation is explained based on the results given by both optical diagnostics and hydrodynamic modeling by a collision of shocks originated from two distinct zones of laser energy deposition.

  11. Approximated transport-of-intensity equation for coded-aperture x-ray phase-contrast imaging.

    Science.gov (United States)

    Das, Mini; Liang, Zhihua

    2014-09-15

    Transport-of-intensity equations (TIEs) allow better understanding of image formation and assist in simplifying the "phase problem" associated with phase-sensitive x-ray measurements. In this Letter, we present for the first time to our knowledge a simplified form of TIE that models x-ray differential phase-contrast (DPC) imaging with coded-aperture (CA) geometry. The validity of our approximation is demonstrated through comparison with an exact TIE in numerical simulations. The relative contributions of absorption, phase, and differential phase to the acquired phase-sensitive intensity images are made readily apparent with the approximate TIE, which may prove useful for solving the inverse phase-retrieval problem associated with these CA geometry based DPC.

  12. Intensity of the absorbing dose of the gamma rays in the air of Krusevac during and after nuclear accident in Chernobil

    International Nuclear Information System (INIS)

    Fortuna, D.

    1997-01-01

    In this paper are compared overage daily values of the intensity of the absorbing doses of the gamma rays in the air of Krusevac, during and after nuclear accident in Cernobil. Average daily values of intensity of the absorbing doses of gamma rays in the air of Krusevac, immediately after nuclear accident in Cernobil were, three to seven time higher than of the average daily values of the natural rays. (author)

  13. Energy dependence of photon-induced L shell x-ray intensity ratios in Ta and W

    Energy Technology Data Exchange (ETDEWEB)

    Shatendra, K; Allawadhi, K L; Sood, B S

    1984-02-01

    The L shell x-ray intensity ratios have been measured for the elements Ta and W by photoionization of L shell electrons in the photon energy region 14 <= E <= 44 keV. The experimental results are compared with those calculated at the photon energies used in the present measurements. The measured values show fairly good agreement with the calculated values within the experimental uncertainties. 11 references, 7 figures.

  14. Handling Ibuprofen increases pain tolerance and decreases perceived pain intensity in a cold pressor test.

    Directory of Open Access Journals (Sweden)

    Abraham M Rutchick

    Full Text Available Pain contributes to health care costs, missed work and school, and lower quality of life. Extant research on psychological interventions for pain has focused primarily on developing skills that individuals can apply to manage their pain. Rather than examining internal factors that influence pain tolerance (e.g., pain management skills, the current work examines factors external to an individual that can increase pain tolerance. Specifically, the current study examined the nonconscious influence of exposure to meaningful objects on the perception of pain. Participants (N = 54 completed a cold pressor test, examined either ibuprofen or a control object, then completed another cold pressor test. In the second test, participants who previously examined ibuprofen reported experiencing less intense pain and tolerated immersion longer (relative to baseline than those who examined the control object. Theoretical and applied implications of these findings are discussed.

  15. Disk Disruptions and X-ray Intensity Excursions in Cyg X-2, LMC X-3 and Cyg X-3

    Science.gov (United States)

    Boyd, P. T.; Smale, A. P.

    2001-05-01

    The RXTE All Sky Monitor soft X-ray light curves of many X-ray binaries show long-term intensity variations (a.k.a "superorbital periodicities") that have been ascribed to precession of a warped, tilted accretion disk around the X-ray source. We have found that the excursion times between X-ray minima in Cyg X-2 can be characterized as a series of integer multiples of the 9.8 binary orbital period, (as opposed to the previously reported stable 77.7 day single periodicity, or a single modulation whose period changes slowly with time). While the data set is too short for a proper statistical analysis, it is clear that the length of any given intensity excursion cannot be used to predict the next (integer) excursion length in the series. In the black hole candidate system LMC X-3, the excursion times are shown to be related to each other by rational fractions. We find that the long term light curve of the unusual galactic X-ray jet source Cyg X-3 can also be described as a series of intensity excursions related to each other by integer multiples of a fundamental underlying clock. In the latter cases, the clock is apparently not related to the known binary periods. A unified physical model, involving both an inclined accretion disk and a fixed-probability disk disruption mechanism is presented, and compared with three-body scattering results. Each time the disk passes through the orbital plane it experiences a fixed probability P that it will disrupt. This model has testable predictions---the distribution of integers should resemble that of an atomic process with a characteristic half life. Further analysis can support or refute the model, and shed light on what system parameters effectively set the value of P.

  16. Effect of external magnetic field on the Kβ/Kα X-ray intensity ratios of TixNi1-x alloys excited by 59.54 and 22.69keV photons.

    Science.gov (United States)

    Perişanoğlu, Ufuk; Alım, Bünyamin; Uğurlu, Mine; Demir, Lütfü

    2016-09-01

    The effects of external magnetic field and exciting photon energies on the Kβ/Kα X-ray intensity ratios of various alloy compositions of Ti-Ni transition metal alloys have been investigated in this work using X-ray fluorescence spectroscopy. The spectrum of characteristic K-X-ray photons from pure Ti, pure Ni and TixNi1-x (x=0.30; 0.40; 0.50; 0.60; 0.70) alloys were detected with a high resolution Si (Li) solid-state detector. Firstly, Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni and TixNi1-x alloys were measured following excitation by 59.54keV γ-rays from a 200mCi (241)Am radioactive point source without any magnetic field and under 0.5 and 1T external magnetic fields, separately. Later, the same measurements were repeated under the same experimental conditions for 22.69keV X-rays from a 370 MBq(1)(0)(9)Cd radioactive point source. The results obtained for Kβ/Kα X-ray intensity ratios of pure Ti, pure Ni, Ti and Ni in various Ti-Ni alloys were evaluated in terms of both external magnetic field effect and exciting photon energy effect. When the results obtained for both exciting photon energies are evaluated in terms of changing of Kβ/Kα X-ray intensity ratios depending on the alloy composition, the tendency of these changes are observed to be similar. Also, Kβ/Kα X-ray intensity ratios for all samples examined have changed with increasing external magnetic field. Therefore, the results obtained have shown that Kβ/Kα X-ray intensity ratios of Ti and Ni in TixNi1-x alloys are connected with the external magnetic field. The present study makes it possible to perform reliable interpretation of experimental Kβ/Kα X-ray intensity ratios for Ti, Ni and TixNi1-x alloys and can also provide quantitative information about the changes of the Kβ/Kα X-ray intensity ratios of these metals with alloy composition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Endurance training of moderate intensity increases testosterone concentration in young, healthy men.

    Science.gov (United States)

    Grandys, M; Majerczak, J; Duda, K; Zapart-Bukowska, J; Kulpa, J; Zoladz, J A

    2009-07-01

    The aim of this study was to investigate the effect of short-term, moderate intensity and low volume endurance training on gonadal hormone profile in untrained men. Fifteen young, healthy men performed an endurance training of 5-week duration on a cycle ergometer. Before and after the exercise program all participants completed a maximal incremental test. Concentration of testosterone (T), sex hormone-binding globulin (SHBG) and cortisol (C) as well as blood morphology were determined in venous blood samples at rest both before and after the training. The training program resulted in 3.7% improvement of maximal oxygen uptake (VO(2max)) and 8.2% improvement of power output reached at VO(2max) (PO (max)). This was accompanied by significant increase in T (from 18.84+/-5.73 nmol.l(-1) to 22.03+/-6.61 nmol.l(-1), p = 0.0004) and calculated fT concentration (from 374+/-116 pmol.l(-1) to 470+/-153 pmol.l(-1), p = 0.00005). Moreover, the training caused a significant decrease in SHBG concentration (from 34.45+/-11.26 nmol.l(-1) to 31.95+/-10.40 nmol.l(-1), p = 0.01), whereas no significant changes were found in the cortisol concentration (334+/-138 nmol.l(-1) vs. 367+/-135 nmol.l(-1) for pre- and post-training measures, respectively, p = 0.50) and T/C and fT/C ratios. We have concluded that short-term, moderate intensity and low volume endurance training can significantly increase testosterone concentration in previously untrained men.

  18. Modelling properties of hard x-rays generated by the interaction between relativistic electrons and very intense laser beams

    International Nuclear Information System (INIS)

    Popa, Alexandru

    2009-01-01

    In a previous paper we presented a calculation model for high harmonic generation by relativistic Thomson scattering of the electromagnetic radiation by free electrons. In this paper we present a similar model for the calculation of the energies of hard x-rays (20- 200 keV) resulted from the interaction between relativistic electrons (20-100 MeV) and very intense laser beams. Starting from the relativistic equations of motion of an electron in the electromagnetic field we show that the Lienard-Wiechert equation leads to electromagnetic waves whose frequencies are in the domain of hard x-rays. When the relativistic parameter of the laser beam is greater than unity, the model predicts the existence of harmonics of the above frequencies. Our theoretical values are in good agreement with experimental values of the x-ray energies from the literature and predict accurately their angular distribution.

  19. Multimodal high-intensity interval training increases muscle function and metabolic performance in females.

    Science.gov (United States)

    Buckley, Stephanie; Knapp, Kelly; Lackie, Amy; Lewry, Colin; Horvey, Karla; Benko, Chad; Trinh, Jason; Butcher, Scotty

    2015-11-01

    High-intensity interval training (HIIT) is a time-efficient method of improving aerobic and anaerobic power and capacity. In most individuals, however, HIIT using modalities such as cycling, running, and rowing does not typically result in increased muscle strength, power, or endurance. The purpose of this study is to compare the physiological outcomes of traditional HIIT using rowing (Row-HIIT) with a novel multimodal HIIT (MM-HIIT) circuit incorporating multiple modalities, including strength exercises, within an interval. Twenty-eight recreationally active women (age 24.7 ± 5.4 years) completed 6 weeks of either Row-HIIT or MM-HIIT and were tested on multiple fitness parameters. MM-HIIT and Row-HIIT resulted in similar improvements (p HIIT group had significant (p HIIT group had no increase in any muscle performance variable (p values 0.33-0.90). Post-training, 1-repetition maximum (1RM) squat (64.2 ± 13.6 vs. 45.8 ± 16.2 kg, p = 0.02), 1RM press (33.2 ± 3.8 vs. 26.0 ± 9.6 kg, p = 0.01), and squat endurance (23.9 ± 12.3 vs. 10.2 ± 5.6 reps, p HIIT group than in the Row-HIIT group. MM-HIIT resulted in similar aerobic and anaerobic adaptations but greater muscle performance increases than Row-HIIT in recreationally active women.

  20. High-intensity endurance training increases nocturnal heart rate variability in sedentary participants

    Directory of Open Access Journals (Sweden)

    A Nummela

    2016-01-01

    Full Text Available The effects of endurance training on endurance performance characteristics and cardiac autonomic modulation during night sleep were investigated during two 4-week training periods. After the first 4-week training period (3 x 40 min per week, at 75% of HRR the subjects were divided into HIGH group (n = 7, who performed three high-intensity endurance training sessions per week; and CONTROL group (n = 8 who did not change their training. An incremental treadmill test was performed before and after the two 4-weektraining periods. Furthermore, nocturnal RR-intervals were recorded after each training day. In the second 4-weektraining period HIGH group increased their V0Zmax (P = 0.005 more than CONTROL group. At the same time, nocturnal HR decreased (P = 0.039 and high-frequency power (HFP increased (P = 0.003 in HIGH group while no changes were observed in CONTROL group. Furthermore, a correlation was observed between the changes in nocturnal HFP and changes in V0Zmax during the second 4-week training period (r = 0.90, P < 0.001. The present study showed that the increased HFP is related to improved VO2max in sedentary subjects suggesting that nocturnal HFP can provide a useful method in monitoring individual responses to endurance training.

  1. Fermi-LAT γ-ray anisotropy and intensity explained by unresolved radio-loud active galactic nuclei

    International Nuclear Information System (INIS)

    Mauro, Mattia Di; Cuoco, Alessandro; Donato, Fiorenza; Siegal-Gaskins, Jennifer M.

    2014-01-01

    Radio-loud active galactic nuclei (AGN) are expected to contribute substantially to both the intensity and anisotropy of the isotropic γ-ray background (IGRB). In turn, the measured properties of the IGRB can be used to constrain the characteristics of proposed contributing source classes. We consider individual subclasses of radio-loud AGN, including low-, intermediate-, and high-synchrotron-peaked BL Lacertae objects, flat-spectrum radio quasars, and misaligned AGN. Using updated models of the γ-ray luminosity functions of these populations, we evaluate the energy-dependent contribution of each source class to the intensity and anisotropy of the IGRB. We find that collectively radio-loud AGN can account for the entirety of the IGRB intensity and anisotropy as measured by the Fermi Large Area Telescope (LAT). Misaligned AGN provide the bulk of the measured intensity but a negligible contribution to the anisotropy, while high-synchrotron-peaked BL Lacertae objects provide the dominant contribution to the anisotropy. In anticipation of upcoming measurements with the Fermi-LAT and the forthcoming Cherenkov Telescope Array, we predict the anisotropy in the broader energy range that will be accessible to future observations

  2. Fermi-LAT γ-ray anisotropy and intensity explained by unresolved radio-loud active galactic nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Mauro, Mattia Di; Cuoco, Alessandro; Donato, Fiorenza [Dipartimento di Fisica, Università di Torino, via P. Giuria 1, Torino, 10125 Italy (Italy); Siegal-Gaskins, Jennifer M., E-mail: mattia.dimauro@to.infn.it, E-mail: alessandro.cuoco@to.infn.it, E-mail: donato@to.infn.it, E-mail: jsg@tapir.caltech.edu [California Institute of Technology, 1200 E. California Blvd., Pasadena, CA, 91125 (United States)

    2014-11-01

    Radio-loud active galactic nuclei (AGN) are expected to contribute substantially to both the intensity and anisotropy of the isotropic γ-ray background (IGRB). In turn, the measured properties of the IGRB can be used to constrain the characteristics of proposed contributing source classes. We consider individual subclasses of radio-loud AGN, including low-, intermediate-, and high-synchrotron-peaked BL Lacertae objects, flat-spectrum radio quasars, and misaligned AGN. Using updated models of the γ-ray luminosity functions of these populations, we evaluate the energy-dependent contribution of each source class to the intensity and anisotropy of the IGRB. We find that collectively radio-loud AGN can account for the entirety of the IGRB intensity and anisotropy as measured by the Fermi Large Area Telescope (LAT). Misaligned AGN provide the bulk of the measured intensity but a negligible contribution to the anisotropy, while high-synchrotron-peaked BL Lacertae objects provide the dominant contribution to the anisotropy. In anticipation of upcoming measurements with the Fermi-LAT and the forthcoming Cherenkov Telescope Array, we predict the anisotropy in the broader energy range that will be accessible to future observations.

  3. Application of different qualities of X-rays by X-ray microradiography to increase the detection efficiency of calcium

    International Nuclear Information System (INIS)

    Fernsebner, M.

    1981-01-01

    It was the goal of this work to evaluate quantitatively the suitability of the radiation quality of tungsten, copper, titanium and scandium anodes for the generation of contrastful microradiographs and thus to increase the detection sensitivity of calcium. Halfwidth determinations were made with aluminium absorbers in air to characterize the different X-ray radiation qualities. Furthermore the dependence of the dose load of the absorber width and the type of the tube was determined in the radiation field for 20 kV anode voltage. Reference step-models were established in order to transfer these results to the calcium detection in microradiograph technology. (orig./HBR) [de

  4. Scaling of Pressure with Intensity in Laser-Driven Shocks and Effects of Hot X-Ray Preheat

    International Nuclear Information System (INIS)

    Colvin, Jeffrey D.; Kalantar, Daniel H.

    2006-01-01

    To drive shocks into solids with a laser we either illuminate the material directly, or to get higher pressures, illuminate a plastic ablator that overlays the material of interest. In both cases the illumination intensity is low, <<1013 W/cm2, compared to that for traditional laser fusion targets. In this regime, the laser beam creates and interacts with a collisional, rather than a collisionless, plasma. We present scaling relationships for shock pressure with intensity derived from simulations for this low-intensity collisional plasma regime. In addition, sometimes the plastic-ablator targets have a thin flash-coating of Al on the plastic surface as a shine-through barrier; this Al layer can be a source of hot x-ray preheat. We discuss how the preheat affects the shock pressure, with application to simulating VISAR measurements from experiments conducted on various lasers on shock compression of Fe

  5. Scaling of Pressure with Intensity in Laser-Driven Shocks and Effects of Hot X-ray Preheat

    International Nuclear Information System (INIS)

    Colvin, J D; Kalantar, D H

    2005-01-01

    To drive shocks into solids with a laser we either illuminate the material directly, or to get higher pressures, illuminate a plastic ablator that overlays the material of interest. In both cases the illumination intensity is low, 13 W/cm 2 , compared to that for traditional laser fusion targets. In this regime, the laser beam creates and interacts with a collisional, rather than a collisionless, plasma. We present scaling relationships for shock pressure with intensity derived from simulations for this low-intensity collisional plasma regime. In addition, sometimes the plastic-ablator targets have a thin flashcoating of Al on the plastic surface as a shine-through barrier; this Al layer can be a source of hot x-ray preheat. We discuss how the preheat affects the shock pressure, with application to simulating VISAR measurements from experiments conducted on various lasers on shock compression of Fe

  6. Measurement of L X-ray intensity ratios in tantalum by proton and Si-ion impact

    International Nuclear Information System (INIS)

    Braich, J.S.; Dhal, B.B.; Singh, B.P.; Padhi, H.C.; Khurana, C.S.; Verma, H.R.

    1996-01-01

    The Lι, Lβ 1,4,6 , Lβ 2,15,3 , Lγ 1 , Lγ 2,3,6 and Lγ 4,4' , X-ray intensities relative to the Lα, caused by the impact of protons of energy 1 to 4.6 MeV and Si-ions of 70 to 98 MeV on Ta targets, h ave been measured. The results show that the intensity ratios drop significantly for all transitions except Lγ 2,3,6 /Lα with Si-ions of the same energy/amu as compared to those of protons. The experimental results have been compared with those based on the ECPSSR theoretical values. From the energy shift and change in the intensity ratios of various transitions caused by Si-ion impact, the number of outer shell vacancies in the M, N and O-shells simultaneous to that of L-shell have been estimat ed. (orig.)

  7. Increase in γ-ray flux at balloon altitude during magnetic disturbances

    International Nuclear Information System (INIS)

    Martin, I.M; Rai, D.B.; Palmeira, R.A.R.; Trivedi, N.B.; Costa, J.M. da.

    1974-01-01

    Balloon observations of γ-rays (0.9 - 18 MeV) and charged particle (>=0.7 MeV) flux made at Sao Jose dos campos (23 0 14'S, 45 0 51'W) on quiet and magnetically disturbed days in October 1973 are presented and discussed. The γ-ray flux during the disturbed period shows a considerable increase compared to the quiet day observations. The charged particles count rate also shows an increase but to a much smaller extent. The increase in the γ-ray flux is attributed to the bremsstrahlung of precipitating high energy electrons from the inner radiation belt. A spectral analysis of the count rate of γ-rays shows that the increase in the flux is more pronounced on the low energy end (0.9 - 20 MeV) of the spectrum which lends further support to the bremsstrahlung explanation. Based on the photon spectrum in the range 0.9 - 18 MeV the spectrum of the precipitating electron causing the γ-ray emission is calculated. The photon spectrum is of the form dN/dE α E sup( - 2.2) in the range 0.9 - 2.5 MeV and dN/dE approximately E sup( - 1.1) in the range 7.0 - 18 MeV. Thus it may be concluded that the increase in the γ-ray flux is due to the precipitation of electrons of the inner radiation belt with E > 20 MeV

  8. Gross separation approaching a blunt trailing edge as the turbulence intensity increases.

    Science.gov (United States)

    Scheichl, B

    2014-07-28

    A novel rational description of incompressible two-dimensional time-mean turbulent boundary layer (BL) flow separating from a bluff body at an arbitrarily large globally formed Reynolds number, Re, is devised. Partly in contrast to and partly complementing previous approaches, it predicts a pronounced delay of massive separation as the turbulence intensity level increases. This is bounded from above by a weakly decaying Re-dependent gauge function (hence, the BL approximation stays intact locally), and thus the finite intensity level characterizing fully developed turbulence. However, it by far exceeds the moderate level found in a preceding study which copes with the associated moderate delay of separation. Thus, the present analysis bridges this self-consistent and another forerunner theory, proposing extremely retarded separation by anticipating a fully attached external potential flow. Specifically, it is shown upon formulation of a respective distinguished limit at which rate the separation point and the attached-flow trailing edge collapse as [Formula: see text] and how on a short streamwise scale the typical small velocity deficit in the core region of the incident BL evolves to a large one. Hence, at its base, the separating velocity profile varies generically with the one-third power of the wall distance, and the classical triple-deck problem describing local viscous-inviscid interaction crucial for moderately retarded separation is superseded by a Rayleigh problem, governing separation of that core layer. Its targeted solution proves vital for understanding the separation process more close to the wall. Most importantly, the analysis does not resort to any specific turbulence closure. A first comparison with the available experimentally found positions of separation for the canonical flow past a circular cylinder is encouraging. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  9. Increased vocal intensity due to the Lombard effect in speakers with Parkinson's disease: simultaneous laryngeal and respiratory strategies.

    Science.gov (United States)

    Stathopoulos, Elaine T; Huber, Jessica E; Richardson, Kelly; Kamphaus, Jennifer; DeCicco, Devan; Darling, Meghan; Fulcher, Katrina; Sussman, Joan E

    2014-01-01

    The objective of the present study was to investigate whether speakers with hypophonia, secondary to Parkinson's disease (PD), would increases their vocal intensity when speaking in a noisy environment (Lombard effect). The other objective was to examine the underlying laryngeal and respiratory strategies used to increase vocal intensity. Thirty-three participants with PD were included for study. Each participant was fitted with the SpeechVive™ device that played multi-talker babble noise into one ear during speech. Using acoustic, aerodynamic and respiratory kinematic techniques, the simultaneous laryngeal and respiratory mechanisms used to regulate vocal intensity were examined. Significant group results showed that most speakers with PD (26/33) were successful at increasing their vocal intensity when speaking in the condition of multi-talker babble noise. They were able to support their increased vocal intensity and subglottal pressure with combined strategies from both the laryngeal and respiratory mechanisms. Individual speaker analysis indicated that the particular laryngeal and respiratory interactions differed among speakers. The SpeechVive™ device elicited higher vocal intensities from patients with PD. Speakers used different combinations of laryngeal and respiratory physiologic mechanisms to increase vocal intensity, thus suggesting that disease process does not uniformly affect the speech subsystems. Readers will be able to: (1) identify speech characteristics of people with Parkinson's disease (PD), (2) identify typical respiratory strategies for increasing sound pressure level (SPL), (3) identify typical laryngeal strategies for increasing SPL, (4) define the Lombard effect. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Hard X-ray dose intensity and spatial distribution in a plasma focus ...

    Indian Academy of Sciences (India)

    Roomi et al [17] studied the effect of applied voltage and nitrogen gas pressure ... optimum conditions for X-ray production; their results showed that at each discharge ..... [23] G Foldiak, Industrial application of radioisotopes (Elsevier Science, ...

  11. Periodic variations of cosmic ray intensity with period of -37 minute observed on April 25th, 1984

    International Nuclear Information System (INIS)

    Sakai, Takasuke; Kato, Masahito; Takei, Ryoji; Tamai, Eiji

    1985-01-01

    Existence of cosmic ray variation with period ranging from a few hours to seconds during geomagnetically quiet and perturb period at different altitude with different detector, was reported previously. As short period variation is thought to be transient with small amplitude fluctuation, consequently high counting rate of cosmic ray and appropriate method for finding short periodicity, is required. Further, there is similar phenomenon in which short variation, followed by storm sudden commencement (SSC) and/or Forbush decrease (FD) occurs. In 1979, Kato et al. used 3 minutes data at Mt. Norikura and obtained -6 x 10 5 count/min, and tried to find out short periodicity of cosmic ray around SSC, but no clear conclusion was obtained. T. Sakai, et al., used plastic scintillation counter of Akeno observatory, following their preceding work. The counter has an area about 154 m 2 . High counting rate of -2 x 10 6 counts/min. was observed at Akeno which revealed the existence of -37 minute periodical oscillation with an amplitude of 0.1 % in p-p during the time period of 1300 - 1900 UT on April 25th 1984, one day before FD. Observed periodical oscillation of cosmic ray counting rate may be the result of the changes in magnetic field. But, it must be noted that there remains possibility of oscillation of cosmic ray intensity in the interplanetary space during the period, independent of geomagnetic field. (author)

  12. Observation of material, thickness, and bremsstrahlung x-ray intensity dependent effects in moderate and high Z targets in a gamma and x-ray LIDAR experiment

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaodong, E-mail: xzhang39@utk.edu [Department of Nuclear Engineering, University of Tennessee, TN 37996 (United States); Ayaz-Maierhafer, Birsen; Laubach, Mitchell A. [Department of Nuclear Engineering, University of Tennessee, TN 37996 (United States); Hayward, Jason P. [Department of Nuclear Engineering, University of Tennessee, TN 37996 (United States); Oak Ridge National Lab, Oak Ridge, TN 37831 (United States)

    2015-06-01

    A high energy gamma and x-ray LIDAR system consisting of a fast pulse (~50 ps, FWHM) LINAC and a Cherenkov detection system was used to investigate response differences among materials, their thicknesses, and bremsstrahlung x-ray intensities. The energies and pulse width of electrons used to produce bremsstrahlung x-rays were set at 20 or 40 MeV and 50 ps FWHM duration, respectively. The Cherenkov detector was built with a fused silica glass optically coupled to a 51 mm fast timing photomultiplier tube, which has an intrinsic energy threshold of 340.7 keV for Compton backscattered gammas. Such a fast detection system yields a coincidence resolving time of 93 ps FWHM, which is equivalent to a depth resolving capability of about 3 cm FWHM. The thicknesses of iron and lead targets were varied from 1 in. to 7 in. with a step of 1 in., and the thicknesses of DU were varied from 1/3 in. to 1 in. with a step of 1/3 in. The experimental results show that iron targets tend to produce a factor of five less observed x-rays and gammas, with less energetic photoelectron frequency distributions, compared with DU and lead targets for the same beam intensity and target thicknesses. Additionally, the self-shielding effect causes the lead to yield more gammas than the DU considering the experimental observation point. For the setup used in this study, a charge per pulse in the range of 1–2.5 nC yields the best resolving capability between the DU and lead targets.

  13. Beta decay of the fission product 125Sb and a new complete evaluation of absolute gamma ray transition intensities

    Science.gov (United States)

    Rajput, M. U.; Ali, N.; Hussain, S.; Mujahid, S. A.; MacMahon, D.

    2012-04-01

    The radionuclide 125Sb is a long-lived fission product, which decays to 125Te by negative beta emission with a half-life of 1008 day. The beta decay is followed by the emission of several gamma radiations, ranging from low to medium energy, that can suitably be used for high-resolution detector calibrations, decay heat calculations and in many other applications. In this work, the beta decay of 125Sb has been studied in detail. The complete published experimental data of relative gamma ray intensities in the beta decay of the radionuclide 125Sb has been compiled. The consistency analysis was performed and discrepancies found at several gamma ray energies. Evaluation of the discrepant data was carried out using Normalized Residual and RAJEVAL methods. The decay scheme balance was carried out using beta branching ratios, internal conversion coefficients, populating and depopulating gamma transitions to 125Te levels. The work has resulted in the consistent conversion factor equal to 29.59(13) %, and determined a new evaluated set of the absolute gamma ray emission probabilities. The work has also shown 22.99% of the delayed intensity fraction as outgoing from the 58 d isomeric 144 keV energy level and 77.01% of the prompt intensity fraction reaching to the ground state from the other excited states. The results are discussed and compared with previous evaluations. The present work includes additional experimental data sets which were not included in the previous evaluations. A new set of recommended relative and absolute gamma ray emission probabilities is presented.

  14. L X-ray intensity ratio measurements using selective L sub-shell photo-ionisation on synchrotron

    Science.gov (United States)

    Bansal, Himani; Tiwari, M. K.; Mittal, Raj

    2017-10-01

    Lα/Lℓ, Lβ /Lℓ and Lγ/Lℓ intensity ratios have been measured for elements in the range 66≤Z≤83 at tuned photon energies on synchrotron beam line-16 at Indus-2, India. For each element, three incident energies Ei were E3; EL3 EL1 where ELi are Li absorption edge energies of the element. Emitted L X-ray spectrum of an element constitutes a number of X-ray lines generally grouped into four main groups due to limited resolution of available detectors as Lℓ(L3-M1), Lα(L3-M4,5), Lβ(L1-M2,3,4,5,N4; L2-M3,4; L3-N1,4,5,O1,4,5) and Lγ(L2-N1,4,O1,4; L1-N2,3,5,O3,2). Lα and Lℓ both comprise only the lines feeding L3 level and Lβ group comprises X-ray lines feeding all the three sub-shells where as Lγ involves contribution from L1 and L2 feedings. Only E3 excitation gives the ratios free from intra sub-shell Coster-Kronig (CK) transitions while excitations E2 and E1 give CK affected Lβ/Lℓ and Lγ/Lℓ X-ray intensity ratios and Lα/Lℓ still remains free from CKs. The pattern of intensity ratios at three excitation energies of elements was well interpreted in terms of on/off of CK transitions (Bambynek et al., 1972; Campbell, 2003) and outer shell electron filling configuration (Scofield, 1973).

  15. Beta decay of the fission product 125Sb and a new complete evaluation of absolute gamma ray transition intensities

    International Nuclear Information System (INIS)

    Rajput, M.U.; Ali, N.; Hussain, S.; Mujahid, S.A.; MacMahon, D.

    2012-01-01

    The radionuclide 125 Sb is a long-lived fission product, which decays to 125 Te by negative beta emission with a half-life of 1008 day. The beta decay is followed by the emission of several gamma radiations, ranging from low to medium energy, that can suitably be used for high-resolution detector calibrations, decay heat calculations and in many other applications. In this work, the beta decay of 125 Sb has been studied in detail. The complete published experimental data of relative gamma ray intensities in the beta decay of the radionuclide 125 Sb has been compiled. The consistency analysis was performed and discrepancies found at several gamma ray energies. Evaluation of the discrepant data was carried out using Normalized Residual and RAJEVAL methods. The decay scheme balance was carried out using beta branching ratios, internal conversion coefficients, populating and depopulating gamma transitions to 125 Te levels. The work has resulted in the consistent conversion factor equal to 29.59(13) %, and determined a new evaluated set of the absolute gamma ray emission probabilities. The work has also shown 22.99% of the delayed intensity fraction as outgoing from the 58 d isomeric 144 keV energy level and 77.01% of the prompt intensity fraction reaching to the ground state from the other excited states. The results are discussed and compared with previous evaluations. The present work includes additional experimental data sets which were not included in the previous evaluations. A new set of recommended relative and absolute gamma ray emission probabilities is presented.

  16. The heart rate increase at the onset of high-work intensity exercise is accelerated by central blood volume loading.

    Science.gov (United States)

    Miyamoto, Tadayoshi; Oshima, Yoshitake; Ikuta, Komei; Kinoshita, Hiroshi

    2006-01-01

    Using a water immersion (WI) method, the combined effect of central blood volume (CBV) loading and work intensity on the time course of heart rate (HR) at the onset of upright dynamic exercise was investigated. Seven males cranked a cycle ergometer for 12 min using their un-immersed arms at low-, moderate- and high-work intensities, followed by a 12-min rest. For WI, the pre-exercise resting cardiac output increased by 36%, while HR decreased by 22% [from 76.8 (10.4) to 59.6 (9.8) beats/min]. WI also increased the high-frequency (HF, 0.15-0.40 Hz) component of the HR variability, suggesting an increased vagal activity. During the initial 2 min of the exercise period at low-work intensity, HR increased by 34.9 and 25.8% in the WI and control conditions, respectively. These were 117 and 73% at high-work intensity, indicating more accelerated HR with WI than the control. The plasma norepinephrine concentration increased less during high-work intensity exercise during WI, as compared to exercise during control conditions. In conclusion, the HR increase at the onset of high-work intensity exercise is accelerated by CBV loading but not at low intensity, possibly reflecting vago-sympathetic interaction and reduced baroreflex sensitivity.

  17. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

    International Nuclear Information System (INIS)

    Kavanaugh, James A.; Hogstrom, Kenneth R.; Fontenot, Jonas P.; Henkelmann, Gregory; Chu, Connel; Carver, Robert A.

    2013-01-01

    Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94

  18. Z-pinches as intense x-ray sources for high energy density physics application

    International Nuclear Information System (INIS)

    Matzen, M.K.

    1997-01-01

    Fast z-pinch implosions can convert more than 10% of the stored electrical energy in a pulsed-power accelerator into x rays. These x rays are produced when an imploding cylindrical plasma, driven by the magnetic field pressure associated with very large axial currents, stagnates upon the cylindrical axis of symmetry. On the Saturn pulsed-power accelerator at Sandia National Laboratories, for example, currents of 6 to 8 MA with a risetime of less than 50 ns are driven through cylindrically-symmetric loads, producing implosions velocities as high as 100 cm/μs and x-ray energies as high as 500 kJ. The keV component of the resulting x-ray spectrum has been used for many years 8 a radiation source for material response studies. Alternatively, the x-ray output can be thermalized into a near-Planckian x-ray source by containing it within a large cylindrical radiation case. These large volume, long-lived radiation sources have recently been used for ICF-relevant ablator physics experiments as well as astrophysical opacity and radiation-material interaction experiments. Hydromagnetic Rayleigh-Taylor instabilities and cylindrical load symmetry are critical, limiting factors in determining the assembled plasma densities and temperatures, and thus in the x-ray pulse widths that can be produced on these accelerators. In recent experiments on the Saturn accelerator, these implosion nonuniformities have been minimized by using uniform-fill gas puff loads or by using wire arrays with as many a 192 wires. These techniques produced significant improvements in the pinched plasma quality, Zn reproducibility, and x-ray output power. X-ray pulse widths of less than 5 ns and peak powers of 75±10 TW have been achieved with arrays of 120 tungsten wires. These powers represent greater than a factor of three in power amplification over the electrical power of the Saturn n accelerator, and are a record for x-ray powers in the laboratory

  19. Analysis of gamma ray intensity on the S/C vent pipes area in the unit 2 reactor building of the Fukushima Daiichi Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Choi, Young Soo; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The robot is equipped with cameras, a dosimeter, and 2 DOF (degree of freedom) manipulation arms. It loads a small vehicle equipped with a camera that can access and inspect narrow areas. TEPCO is using the four-legged walking robot to inspect the suppression chamber (S/C) area of the unit 2 reactor building basement in the Fukushima Daiichi Nuclear Power Plant. The robot carried out 6 missions for about four months, from 11 December, 2012 to 15 March, 2013, where it examined an evidence of a leakage of radioactivity contaminated water in the S/C area of unit 2 reactor building. When a camera's signal processing unit, which is consist of ASIC and FPGA devices manufactured by a CMOS fabrication process, is exposed to a higher dose rate gamma ray, the speckle distribution in the camera image increase more. From the inspection videos, released by TEPCO, of the underground 8 vent pipes in the unit 2 reactor building, we analyzed the speckle distribution from the high dose-rate gamma rays. Based on the distribution of the speckle, we attempted to characterize the vent pipe with much radioactivity contaminated materials among the eight vent pipes connected to the PCV. The numbers of speckles viewed in the image of a CCD (or CMOS) camera are related to an intensity of the gamma ray energy emitted by a nuclear fission reaction from radioactivity materials. The numbers of speckles generated by gamma ray irradiation in the camera image are calculated by an image processing technique. Therefore, calculating the speckles counts, we can determine the vent pipe with relatively most radioactivity-contaminated materials among the other vent pipes. From the comparison of speckles counts calculated in the inspection image of the vent pipe with the speckles counts extracted by gamma ray irradiation experiment of the same small vehicle camera model loaded with the four-legged walking robot, we can qualitatively estimate the gamma ray dose-rate in the S/C vent pipe area of the

  20. Transmutation of sup 2 sup 0 sup 4 Pb in an intensive gamma-ray flux

    CERN Document Server

    Ishkhanov, B S

    2001-01-01

    Transmutation chain formation during irradiation with various intensities of bremsstrahlung photon beam is analysed. The main features of transmutation chain formation by photons with energies corresponding to the giant dipole resonance are discussed.

  1. Variable-Intensity Simulated Team-Sport Exercise Increases Daily Protein Requirements in Active Males.

    Science.gov (United States)

    Packer, Jeffrey E; Wooding, Denise J; Kato, Hiroyuki; Courtney-Martin, Glenda; Pencharz, Paul B; Moore, Daniel R

    2017-01-01

    Protein requirements are generally increased in strength and endurance trained athletes relative to their sedentary peers. However, less is known about the daily requirement for this important macronutrient in individuals performing variable intensity, stop-and-go type exercise that is typical for team sport athletes. The objective of the present study was to determine protein requirements in active, trained adult males performing a simulated soccer match using the minimally invasive indicator amino acid oxidation (IAAO) method. After 2 days of controlled diet (1.2 g⋅kg -1 ⋅day -1 protein), seven trained males (23 ± 1 years; 177.5 ± 6.7 cm; 82.3 ± 6.1 kg; 13.5% ± 4.7% body fat; 52.3 ± 5.9 ml O 2 ⋅kg -1 ⋅min -1 ; mean ± SD) performed an acute bout of variable intensity exercise in the form of a modified Loughborough Intermittent Shuttle Test (4 × 15 min of exercise over 75 min). Immediately after exercise, hourly meals were consumed providing a variable amount of protein (0.2-2.6 g⋅kg -1 ⋅day -1 ) and sufficient energy and carbohydrate (6 g⋅kg -1 ⋅day -1 ). Protein was provided as a crystalline amino acids modeled after egg protein with the exception of phenylalanine and tyrosine, which were provided in excess to ensure the metabolic partitioning of the indicator amino acid (i.e., [1- 13 C]phenylalanine included within the phenylalanine intake) was directed toward oxidation when protein intake was limiting. Whole body phenylalanine flux and 13 CO 2 excretion (F 13 CO 2 ) were determined at metabolic and isotopic steady state from urine and breath samples, respectively. Biphasic linear regression analysis was performed on F 13 CO 2 to determine the estimated average requirement (EAR) for protein with a safe intake defined as the upper 95% confidence interval. Phenylalanine flux was not impacted by protein intake ( P  = 0.45). Bi-phase linear regression ( R 2  = 0.64) of F 13 CO 2 resulted

  2. Variable-Intensity Simulated Team-Sport Exercise Increases Daily Protein Requirements in Active Males

    Directory of Open Access Journals (Sweden)

    Jeffrey E. Packer

    2017-12-01

    Full Text Available Protein requirements are generally increased in strength and endurance trained athletes relative to their sedentary peers. However, less is known about the daily requirement for this important macronutrient in individuals performing variable intensity, stop-and-go type exercise that is typical for team sport athletes. The objective of the present study was to determine protein requirements in active, trained adult males performing a simulated soccer match using the minimally invasive indicator amino acid oxidation (IAAO method. After 2 days of controlled diet (1.2 g⋅kg−1⋅day−1 protein, seven trained males (23 ± 1 years; 177.5 ± 6.7 cm; 82.3 ± 6.1 kg; 13.5% ± 4.7% body fat; 52.3 ± 5.9 ml O2⋅kg−1⋅min-1; mean ± SD performed an acute bout of variable intensity exercise in the form of a modified Loughborough Intermittent Shuttle Test (4 × 15 min of exercise over 75 min. Immediately after exercise, hourly meals were consumed providing a variable amount of protein (0.2–2.6 g⋅kg−1⋅day−1 and sufficient energy and carbohydrate (6 g⋅kg−1⋅day−1. Protein was provided as a crystalline amino acids modeled after egg protein with the exception of phenylalanine and tyrosine, which were provided in excess to ensure the metabolic partitioning of the indicator amino acid (i.e., [1-13C]phenylalanine included within the phenylalanine intake was directed toward oxidation when protein intake was limiting. Whole body phenylalanine flux and 13CO2 excretion (F13CO2 were determined at metabolic and isotopic steady state from urine and breath samples, respectively. Biphasic linear regression analysis was performed on F13CO2 to determine the estimated average requirement (EAR for protein with a safe intake defined as the upper 95% confidence interval. Phenylalanine flux was not impacted by protein intake (P = 0.45. Bi-phase linear regression (R2 = 0.64 of F13CO2 resulted in an EAR

  3. Bench-to-bedside review: Dealing with increased intensive care unit staff turnover: a leadership challenge

    Science.gov (United States)

    Laporta, Denny P; Burns, Judy; Doig, Chip J

    2005-01-01

    Critical care leaders frequently must face challenging situations requiring specific leadership and management skills for which they are, not uncommonly, poorly prepared. Such a fictitious scenario was discussed at a Canadian interdisciplinary critical care leadership meeting, whereby increasing intensive care unit (ICU) staff turnover had led to problems with staff recruitment. Participants discussed and proposed solutions to the scenario in a structured format. The results of the discussion are presented. In situations such as this, the ICU leader should first define the core problem, its complexity, its duration and its potential for reversibility. These factors often reside within workload and staff support issues. Some examples of core problems discussed that are frequently associated with poor retention and recruitment are a lack of a positive team culture, a lack of a favorable ICU image, a lack of good working relationships between staff and disciplines, and a lack of specific supportive resources. Several tools or individuals (typically outside the ICU environment) are available to help determine the core problem. Once the core problem is identified, specific solutions can be developed. Such solutions often require originality and flexibility, and must be planned, with specific short-term, medium-term and long-term goals. The ICU leader will need to develop an implementation strategy for these solutions, in which partners who can assist are identified from within the ICU and from outside the ICU. It is important that the leader communicates to all stakeholders frequently as the process moves forward. PMID:16277732

  4. Low- and high-frequency spectral behavior of cosmic-ray intensity for the period 1953–1996

    Directory of Open Access Journals (Sweden)

    H. Mavromichalaki

    2003-08-01

    Full Text Available A study of the cosmic-ray intensity power spectrum using the Climax Neutron Monitor data in the frequency range from 10-9 Hz to 10-7 Hz (which corresponds to periodicities from 11 years to a few months during the period 1953–1996, was carried out by means of the successive approximations method of analysis and was compared against the power spectrum and the maximum entropy methods. The contributions of the time evolution of several peaks to the global one were obtained. Except for the well-known 11-year and the 1-year variations, peaks at 7.7, 5.5, 2 and 1.7 years are found. Several peaks with periods less than 10 months have appeared in our analysis, while the occurrence of 5.1 months is obtained in all the examined solar cycles with a strong signature in cycle 21. Transitions of these quasi-periodicities are seen in power spectra plots. Some of them can be attributed to the modulation of the cosmic ray intensity by solar activity. Others are sporadic and have been previously attributed to the interplanetary magnetic field. The results obtained support once again the argument regarding the difference in the solar activity between odd and even solar cycles.Key words. Interplanetary physics (Cosmic rays, Interplanetary magnetic fields

  5. Intense γ-ray generation for a polarized positron beam in a linear collider

    Directory of Open Access Journals (Sweden)

    Y. Miyahara

    2001-12-01

    Full Text Available γ-ray generation by Compton backscattering in an optical lens series with periodic focal points is considered to produce a polarized positron beam for a linear collider. The lens series is composed of 20 unit cells with a length of 210 mm. Each lens has a hole to pass an electron beam with an energy of 5.8 GeV and the generated γ rays. It is shown by diffraction analysis that laser beam loss in the series is very small, and the beam size is periodically reduced to 26 μm. Electron beam size is reduced to 34 μm in a superconducting solenoid with a field of 15 T. To get a required γ-ray yield of 7×10^{15} γ/s, only one circularly polarized CO_{2} laser source with a power of 24 kW is needed.

  6. The MIT/OSO 7 catalog of X-ray sources - Intensities, spectra, and long-term variability

    Science.gov (United States)

    Markert, T. H.; Laird, F. N.; Clark, G. W.; Hearn, D. R.; Sprott, G. F.; Li, F. K.; Bradt, H. V.; Lewin, W. H. G.; Schnopper, H. W.; Winkler, P. F.

    1979-01-01

    This paper is a summary of the observations of the cosmic X-ray sky performed by the MIT 1-40-keV X-ray detectors on OSO 7 between October 1971 and May 1973. Specifically, mean intensities or upper limits of all third Uhuru or OSO 7 cataloged sources (185 sources) in the 3-10-keV range are computed. For those sources for which a statistically significant (greater than 20) intensity was found in the 3-10-keV band (138 sources), further intensity determinations were made in the 1-15-keV, 1-6-keV, and 15-40-keV energy bands. Graphs and other simple techniques are provided to aid the user in converting the observed counting rates to convenient units and in determining spectral parameters. Long-term light curves (counting rates in one or more energy bands as a function of time) are plotted for 86 of the brighter sources.

  7. MIT/OSO 7 catalog of x-ray sources: intensities, spectra, and long-term variability

    International Nuclear Information System (INIS)

    Markert, T.H.; Winkler, P.F.; Laird, F.N.; Clark, G.W.; Hearn, D.R.; Sprott, G.F.; Li, F.K.; Bradt, H.V.; Lewin, W.H.G.; Schnopper, H.W.

    1979-01-01

    This paper is a summary of the observations of the cosmic X-ray sky performed by the MIT 1--40 KeV X-ray detectors on the OSO 7 between 1971 October and 1973 May. Specifically, we have computed the mean intensities or upper limits of all third Uhuru or OSO 7 cataloged sources (185 sources) in the 3--10 KeV range. For those sources for which a statistically significant (>20) intensity was found in the 3--10 KeV band (138 sources), further intensity determinations were made in the 1--15 KeV, 1--6 KeV, and 15--40 KeV energy bands. We have provided graphs and other simple techniques to aid the user in converting the observed counting rates to convenient units and in determining spectral parameters. Finally, we have plotted long-term light curves (counting rates in one or more energy bands as a function of time) for 86 of the brighter sources

  8. Future prospect of the research study using intense and bright synchrotron radiation in VUV and soft x-ray region

    International Nuclear Information System (INIS)

    Tanaka, Kenichiro; Miyahara, Tsuneaki

    1987-02-01

    This report is the summary of the contents of the study meeting 'Future prospect of the research study using intense and bright synchrotron radiation in VUV and soft x-ray region' sponsored by PF, held on October 20 and 21, 1986. This study meeting was held by inviting those who are particularly interested in the basic field among the users of VUV and soft x-ray region, and the research on the application field was excluded. The objective of the discussion of this study meeting was to talk about the dream that if a high luminance light source which is 100 - 1000 times more intense in terms of luminous flux intensity is completed, what can we do with it. Three sessions on the themes 'How the existing research fields will develop', 'What the possible new research fields are' and 'Comment from the technical aspect' were held. More than seven years elapsed since the beginning of construction of the Photon Factory. Many excellent results have been obtained. As of October, 1986, the beam lines available for experiment are 11, the themes of common utilization experiment in progress are 300, and the number of registered researchers exceeded 1000. The development of a new light emission source is to be undertaken. (Kako, I.)

  9. High-Intensity Interval Training Increases Cardiac Output and V˙O2max.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael A; Namm, Samantha; Fischer, Anthony; Wood, Kimi M

    2017-02-01

    Increases in maximal oxygen uptake (V˙O2max) frequently occur with high-intensity interval training (HIIT), yet the specific adaptation explaining this result remains elusive. This study examined changes in V˙O2max and cardiac output (CO) in response to periodized HIIT. Thirty-nine active men and women (mean age and V˙O2max = 22.9 ± 5.4 yr and 39.6 ± 5.6 mL·kg·min) performed HIIT and 32 men and women (age and V˙O2max = 25.7 ± 4.5 yr and 40.7 ± 5.2 mL·kg·min) were nonexercising controls (CON). The first 10 sessions of HIIT required eight to ten 60 s bouts of cycling at 90%-110% percent peak power output interspersed with 75 s recovery, followed by randomization to one of three regimes (sprint interval training (SIT), high-volume interval training (HIITHI), or periodized interval training (PER) for the subsequent 10 sessions. Before, midway, and at the end of training, progressive cycling to exhaustion was completed during which V˙O2max and maximal CO were estimated. Compared with CON, significant (P HIIT + SIT (39.8 ± 7.3 mL·kg·min to 43.6 ± 6.1 mL·kg·min), HIIT + HIITHI (41.1 ± 4.9 mL·kg·min to 44.6 ± 7.0 mL·kg·min), and HIIT + PER (39.5 ± 5.6 mL·kg·min to 44.1 ± 5.4 mL·kg·min) occurred which were mediated by significant increases in maximal CO (20.0 ± 3.1 L·min to 21.7 ± 3.2 L·min, P = 0.04). Maximal stroke volume was increased with HIIT (P = 0.04), although there was no change in maximal HR (P = 0.88) or arteriovenous O2 difference (P = 0.36). These CO data are accurate and represent the mean changes from pre- to post-HIIT across all three training groups. Increases in V˙O2max exhibited in response to different HIIT regimes are due to improvements in oxygen delivery.

  10. Measurement of secondary gamma-ray skyshine and groundshine from intense 14 MeV neutron source facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shigeo; Morotomi, Ryutaro; Kondo, Tetsuo; Murata, Isao; Takahashi, Akito [Osaka Univ., Suita (Japan). Dept. of Nuclear Engineering

    2000-03-01

    Secondary gamma-ray skyshine and groundshine, including the direct contribution from the facility building, have been measured with an Hp-Ge detector and an NaI(Tl) detector at the Intense 14 MeV Neutron Source Facility OKTAVIAN of Osaka University, Japan. The mechanism of secondary gamma-rays propagation were analyzed with the measured spectrum with the Hp-Ge detector. The contribution of the skyshine was shown to be a continuum spectrum that was composed of mainly Compton scattered high energy secondary gamma-rays generated in the facility building created by (n, {gamma}) reaction. The contribution of the groundshine considerably contained secondary gamma-rays generated by {sup nat}Si (n, {gamma}) reaction in soil, including the albedo contribution from the ground. And the total contribution contained capture gamma-rays from iron (Fe) and other nuclides. The measurements with the NaI(Tl) detector as well as the Hp-Ge detector were carried out to investigate the dependence of gamma-ray dose as a function of distance from the neutron source up to hundreds meters. Consequently, it was found that the dependence could be fitted with the function of const.{center_dot}exp(-r/{lambda})/r{sup n}, where n values were around 2 except for the skyshine (n {approx} 1). It was thus indicated that the contribution of the skyshine could be propagated farther downfield than the direct contribution from the facility. The measured ratios of the three contributions (skyshine, groundshine, and direct contributions) and the distance dependence in each path were shown to be in good agreement with calculated results by the Monte Carlo transport code MCNP-4A. And the total contributions for the two detectors of NaI(Tl) and Hp-Ge agree excellently with each other. (author)

  11. Large area APDs for low energy X-ray detection in intense magnetic fields

    International Nuclear Information System (INIS)

    Boucher, M.; Huot, O.; Knowles, P.E.; Ludhova, L.; Mulhauser, F.; Schaller, L.A.; Conde, C.A.N.; Santos, J.M.F. dos; Fernandes, L.M.P.; Veloso, J.F.C.A.; Kottmann, F.; Antognini, A.; Pohl, R.; Taqqu, D.

    2003-01-01

    An experiment to measure the energy difference between the 2S-2P atomic levels (Lamb shift) in muonic hydrogen is being prepared at PSI. Since the energy levels of muonic hydrogen are a factor of 186 more energetic than those of hydrogen, according to the ratio of reduced masses, the transitions lie in the soft X-ray region. The experiment needs long-lived muonic hydrogen in the 2S state. This is achieved by stopping a low energy muon beam in a small volume of low pressure hydrogen in a 5 T magnetic field. A pulsed beam from a tunable laser induces the 2S-2P transition and the 1.9 keV X-ray photons resulting from the 2P-1S deexcitation will be detected. Measuring the coincidences between the laser pulse and the X-ray as a function of the laser wavelength allows us to determine the Lamb shift. In this presentation we will discuss the perspectives of using large area avalanche photodiodes for the direct detection of the X-rays. Compared to gaseous detectors, they are more compact and simpler in operation. They are also insensitive to magnetic fields

  12. Large area APDs for low energy X-ray detection in intense magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Boucher, M.; Huot, O.; Knowles, P.E.; Ludhova, L.; Mulhauser, F. E-mail: francoise.mulhauser@unifr.ch; Schaller, L.A.; Conde, C.A.N.; Santos, J.M.F. dos; Fernandes, L.M.P.; Veloso, J.F.C.A.; Kottmann, F.; Antognini, A.; Pohl, R.; Taqqu, D

    2003-06-01

    An experiment to measure the energy difference between the 2S-2P atomic levels (Lamb shift) in muonic hydrogen is being prepared at PSI. Since the energy levels of muonic hydrogen are a factor of 186 more energetic than those of hydrogen, according to the ratio of reduced masses, the transitions lie in the soft X-ray region. The experiment needs long-lived muonic hydrogen in the 2S state. This is achieved by stopping a low energy muon beam in a small volume of low pressure hydrogen in a 5 T magnetic field. A pulsed beam from a tunable laser induces the 2S-2P transition and the 1.9 keV X-ray photons resulting from the 2P-1S deexcitation will be detected. Measuring the coincidences between the laser pulse and the X-ray as a function of the laser wavelength allows us to determine the Lamb shift. In this presentation we will discuss the perspectives of using large area avalanche photodiodes for the direct detection of the X-rays. Compared to gaseous detectors, they are more compact and simpler in operation. They are also insensitive to magnetic fields.

  13. Intensity of Upward Muon Flux Due to Cosmic-Ray Neutrinos Produced in the Atmosphere

    Science.gov (United States)

    Lee, T. D.; Robinson, H.; Schwartz, M.; Cool, R.

    1963-06-01

    Calculations were performed to determine the upward going muon flux leaving the earth's surface after production by cosmic-ray neutrinos in the crust. Only neutrinos produced in the earth's atmosphere are considered. Rates of the order of one per 100 sq m/day might be expected if an intermediate boson exists and has a mass less than 2 Bev. (auth)

  14. Time-dependent, x-ray spectral unfolds and brightness temperatures for intense Li+ ion beam-driven hohlraums

    International Nuclear Information System (INIS)

    Fehl, D.L.; Chandler, G.A.; Biggs, F.; Dukart, R.J.; Moats, A.R.; Leeper, R.J.

    1996-01-01

    X-ray-producing hohlraums are being studied as indirect drives for Inertial Confinement Fusion targets. In a 1994 target series on the PBFAII accelerator, cylindrical hohlraum targets were heated by an intense Li + ion beam and viewed by an array of 13 time-resolved, filtered x-ray detectors (XRDs). The UFO unfold code and its suite of auxiliary functions were used extensively in obtaining time- resolved x-ray spectra and radiation temperatures from this diagnostic. UFO was also used to obtain fitted response functions from calibration data, to simulate data from blackbody x-ray spectra of interest, to determine the suitability of various unfolding parameters (e.g., energy domain, energy partition, smoothing conditions, and basis functions), to interpolate the XRD signal traces, and to unfold experimental data. The simulation capabilities of the code were useful in understanding an anomalous feature in the unfolded spectra at low photon energies (≤ 100 eV). Uncertainties in the differential and energy-integrated unfolded spectra were estimated from uncertainties in the data. The time-history of the radiation temperature agreed well with independent calculations of the wall temperature in the hohlraum

  15. Time-dependent, x-ray spectral unfolds and brightness temperatures for intense Li+ ion beam-driven hohlraums

    International Nuclear Information System (INIS)

    Fehl, D.L.; Chandler, G.A.; Biggs, F.; Dukart, R.J.; Moats, A.R.; Leeper, R.J.

    1997-01-01

    X-ray-producing hohlraums are being studied as indirect drives for inertial confinement fusion targets. In a 1994 target series on the PBFAII accelerator, cylindrical hohlraum targets were heated by an intense Li + ion beam and viewed by an array of 13 time-resolved, filtered x-ray detectors (XRDs). The unfold operator (UFO) code and its suite of auxiliary functions were used extensively in obtaining time-resolved x-ray spectra and radiation temperatures from this diagnostic. The UFO was also used to obtain fitted response functions from calibration data, to simulate data from blackbody x-ray spectra of interest, to determine the suitability of various unfolding parameters (e.g., energy domain, energy partition, smoothing conditions, and basis functions), to interpolate the XRD signal traces, and to unfold experimental data. The simulation capabilities of the code were useful in understanding an anomalous feature in the unfolded spectra at low photon energies (≤100 eV). Uncertainties in the differential and energy-integrated unfolded spectra were estimated from uncertainties in the data. The time endash history of the radiation temperature agreed well with independent calculations of the wall temperature in the hohlraum. copyright 1997 American Institute of Physics

  16. Monte Carlo simulation of photon scattering in x-ray absorption imaging of high-intensity discharge lamps

    Energy Technology Data Exchange (ETDEWEB)

    Curry, J J, E-mail: jjcurry@nist.go [National Institute of Standards and Technology, Gaithersburg, MD 20899-8422 (United States)

    2010-06-16

    Coherent and incoherent scattering of x-rays during x-ray absorption imaging of high-intensity discharge lamps have been studied with Monte Carlo simulations developed specifically for this purpose. The Monte Carlo code is described and some initial results are discussed. Coherent scattering, because of its angular concentration in the forward direction, is found to be the most significant scattering mechanism. Incoherent scattering, although comparably strong, is not as significant because it results primarily in photons being scattered in the rearward direction and therefore out of the detector. Coherent scattering interferes with the detected absorption signal because the path of a scattered photon through the object to be imaged is unknown. Although scattering is usually a small effect, it can be significant in regions of high contrast. At the discharge/wall interface, as many as 50% of the detected photons are scattered photons. The effect of scattering on analysis of Hg distributions has not yet been quantified.

  17. Posttraining Increases in REM Sleep Intensity Implicate REM Sleep in Memory Processing and Provide a Biological Marker of Learning Potential

    Science.gov (United States)

    Nader, Rebecca S.; Smith, Carlyle T.; Nixon, Margaret R.

    2004-01-01

    Posttraining rapid eye movement (REM) sleep has been reported to be important for efficient memory consolidation. The present results demonstrate increases in the intensity of REM sleep during the night of sleep following cognitive procedural/implicit task acquisition. These REM increases manifest as increases in total number of rapid eye…

  18. Expectancy of ergogenicity from sodium bicarbonate ingestion increases high-intensity cycling capacity.

    Science.gov (United States)

    Higgins, Matthew F; Shabir, Akbar

    2016-04-01

    This study examined whether expectancy of ergogenicity of a commonly used nutritional supplement (sodium bicarbonate; NaHCO3) influenced subsequent high-intensity cycling capacity. Eight recreationally active males (age, 21 ± 1 years; body mass, 75 ± 8 kg; height, 178 ± 4 cm; WPEAK = 205 ± 22 W) performed a graded incremental test to assess peak power output (WPEAK), one familiarisation trial and two experimental trials. Experimental trials consisted of cycling at 100% WPEAK to volitional exhaustion (TLIM) 60 min after ingesting either a placebo (PLA: 0.1 g·kg(-1) sodium chloride (NaCl), 4 mL·kg(-1) tap water, and 1 mL·kg(-1) squash) or a sham placebo (SHAM: 0.1 g·kg(-1) NaCl, 4 mL·kg(-1) carbonated water, and 1 mL·kg(-1) squash). SHAM aimed to replicate the previously reported symptoms of gut fullness (GF) and abdominal discomfort (AD) associated with NaHCO3 ingestion. Treatments were administered double blind and accompanied by written scripts designed to remain neutral (PLA) or induce expectancy of ergogenicity (SHAM). After SHAM mean TLIM increased by 9.5% compared to PLA (461 ± 148 s versus 421 ± 150 s; P = 0.048, d = 0.3). Ratings of GF and AD were mild but ~1 unit higher post-ingestion for SHAM. After 3 min TLIM overall ratings of perceived exertion were 1.4 ± 1.3 units lower for SHAM compared to PLA (P = 0.020, d = 0.6). There were no differences between treatments for blood lactate, blood glucose, or heart rate. In summary, ergogenicity after NaHCO3 ingestion may be influenced by expectancy, which mediates perception of effort during subsequent exercise. The observed ergogenicity with SHAM did not affect our measures of cardiorespiratory physiology or metabolic flux.

  19. Calibration of intense 60Co gamma ray sources at the Savannah River Plant

    International Nuclear Information System (INIS)

    Bibler, N.E.

    1976-05-01

    Three different dosimeters were used to calibrate Savannah River Plant 60 Co sources having intensities greater than 10 7 rads/hr. These dosimeters are (a) ceric sulfate dissolved in 0.4M H 2 SO 4 , (b) oxalic acid dissolved in water, and (c) a commercially available nylon film containing a radiochromic dye. Response per unit dose to these dosimeters is independent of radiation intensity at 10 4 to 10 11 rads/hr. The dosimeters were calibrated at 6.0 x 10 5 rads/hr with a 60 Co source whose intensity was determined with the standard Fricke dosimeter. For the sources at 10 7 rads/hr or greater, intensities were calculated from slopes of linear plots of dosimeter response versus irradiation time. Individual dose rates varied from 1.0 x 10 7 to 4.6 x 10 7 rads/hr. Each source was calibrated with at least two different dosimeters. Relative standard deviations varied from 2 to 9 percent. A conservative estimate of the uncertainty in the accuracy of these dosimeters is 10 percent. Of the three dosimeters, the nylon film is easiest to use and is therefore recommended for future calibrations

  20. Prospects for compact high-intensity laser synchrotron x-ray and gamma sources

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1996-11-01

    A laser interacting with a relativistic electron beam behaves like a virtual wiggler of an extremely short period equal to half of the laser wavelength. This approach opens a route to relatively compact, high-brightness x-ray sources alternative or complementary to conventional synchrotron light sources. Although not new, the laser synchrotron source (LSS) concept is still waiting for a convincing demonstration. Available at the BNL Accelerator Test Facility (ATF), a high-brightness electron beam and the high-power CO 2 laser may be used as prototype LSS brick stones. In a feasible demonstration experiment, 10-GW, 100-ps CO 2 laser beam will be brought to a head-on collision with a 10-ps, 0.5-nC, 50 MeV electron bunch. Flashes of collimated 4.7 keV (2.6 angstrom) x-rays of 10-ps pulse duration, with a flux of ∼ 10 19 photons/sec, will be produced via linear Compton backscattering. The x-ray spectrum is tunable proportionally to the e-beam energy. A rational short-term extension of the proposed experiment would be further enhancement of the x-ray flux to the 10 22 photons/sec level, after the ongoing ATF CO 2 laser upgrade to 5 TW peak power and electron bunch shortening to 3 ps is realized. In the future, exploiting the promising approach of a high-gradient laser wake field accelerator, a compact ''table-top'' LSS of monochromatic gamma radiation may become feasible

  1. Prospects for compact high-intensity laser synchrotron x-ray and gamma sources

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.

    1997-01-01

    A laser interacting with a relativistic electron beam behaves like a virtual wiggler of an extremely short period equal to half of the laser wavelength. This approach opens a route to relatively compact, high- brightness x-ray sources alternative or complementary to conventional synchrotron light sources. Although not new, the laser synchrotron source (LSS) concept is still waiting for a convincing demonstration. Available at the BNL Accelerator Test Facility (ATF), a high- brightness electron beam and the high-power C0 2 laser may be used as prototype LSS brick stones. In a feasible demonstration experiment, 10 GW, 100 ps C0 2 laser beam will be brought to a head-on collision with a 10 ps, 0.5 nC, 50 MeV electron bunch. Flashes of collimated 4.7 keV (2.6 A) x-rays of 10-ps pulse duration, with a flux of ∼10 19 photons/sec, will be produced via linear Compton backscattering. The x-ray spectra is tunable proportionally to the e- beam energy. A rational short-term extension of the proposed experiment would be further enhancement of the x-ray flux to the 10 22 photon/sec level, after the ongoing ATF C0 2 laser upgrade to 5 TW peak power and electron bunch shortening to 3 ps is realized. In the future, exploiting the promising approach of a high-gradient laser wake field accelerator, a compact ''table- top'' LSS of monochromatic gamma radiation may become feasible

  2. CROSS-CORRELATION BETWEEN X-RAY AND OPTICAL/NEAR-INFRARED BACKGROUND INTENSITY FLUCTUATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell-Wynne, Ketron; Cooray, Asantha [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Xue, Yongquan [CAS Key Laboratory for Researches in Galaxies and Cosmology, Center for Astrophysics, Department of Astronomy, University of Science and Technology of China, Chinese Academy of Sciences, Hefei, Anhui 230026 (China); Luo, Bin [School of Astronomy and Space Science, Nanjing University, Nanjing, 210093 (China); Brandt, William [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA, 16802 (United States); Koekemoer, Anton [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States)

    2016-12-01

    Angular power spectra of optical and infrared background anisotropies at wavelengths between 0.5 and 5 μ m are a useful probe of faint sources present during reionization, in addition to faint galaxies and diffuse signals at low redshift. The cross-correlation of these fluctuations with backgrounds at other wavelengths can be used to separate some of these signals. A previous study on the cross-correlation between X-ray and Spitzer fluctuations at 3.6 μ m and 4.5 μ m has been interpreted as evidence for direct collapse black holes present at z  > 12. Here we return to this cross-correlation and study its wavelength dependence from 0.5 to 4.5 μ m using Hubble and Spitzer data in combination with a subset of the 4 Ms Chandra observations in GOODS-S/ECDFS. Our study involves five Hubble bands at 0.6, 0.7, 0.85, 1.25, and 1.6 μ m, and two Spitzer -IRAC bands at 3.6 μ m and 4.5 μ m. We confirm the previously seen cross-correlation between 3.6 μ m (4.5 μ m) and X-rays with 3.7 σ (4.2 σ ) and 2.7 σ (3.7 σ ) detections in the soft [0.5–2] keV and hard [2–8] keV X-ray bands, respectively, at angular scales above 20 arcsec. The cross-correlation of X-rays with Hubble is largely anticorrelated, ranging between the levels of 1.4 σ –3.5 σ for all the Hubble and X-ray bands. This lack of correlation in the shorter optical/NIR bands implies the sources responsible for the cosmic infrared background at 3.6 and 4.5 μ m are at least partly dissimilar to those at 1.6 μ m and shorter.

  3. Plans to increase source brightness of NSLS x-ray ring

    International Nuclear Information System (INIS)

    Safranek, J.; Krinsky, S.

    1993-01-01

    We discuss plans to increase the NSLS X-Ray ring source brightness by an order of magnitude. Proposed improvements include doubling current from 250 mA to 500 mA, reducing vertical emittance by a factor of 6 and reducing insertion device gaps and periods by up to a factor of two. Experimental results are reported which indicate we have succeeded in reducing the vertical emittance below 2 Angstrom

  4. Modeling Relativistic Electron Precipitation Bremsstrahlung X-Ray Intensities at 10-100 km Manned Vehicle Altitudes

    Science.gov (United States)

    Krause, L. Habsh; Gilchrist, B. E.; Nishikawa, Ken-Ichi

    2013-01-01

    Relativisitic electron precipitation (REP) events occur when beams or bunches of relativistic electrons of magnetospheric origin enter the Earth's atmosphere, typically at auroral latitudes. REP events are associated with a variety of space weather effects, including production of transitional and bremsstrahlung radiation, catalytic depletion of stratospheric ozone, and scintillation of transionospheric radio waves. This study examines the intensities of x-rays produced at airliner, manned balloon, and space reuseable launch vehicles (sRLVs). The monoenergetic beam is modeled in cylindrical symetry using the paraxial ray equation. Bremsstrahlung photon production is calculated using the traditional Sauter-Elwert cross-section, providing x-ray emission spectra differential in energy and angle. Attenuation is computed for a plane-stratified standard atmosphere, and the loss processes include photoionization, Rayleigh and Compton scattering, electron-positron pair production, and photonuclear interaction. Peak altitudes of electron energy deposition and bremsstrahlung x-ray production were calculated for beams of energies from 1 MeV through 100 MeV. The altitude peak of bremsstrahlung deposition was consistently and significantly lower that that of the electron deposition due to the longer mean free paths of x-rays compared to electrons within the atmosphere. For example, for a nadir-directed monoenergetic 5 MeV beam, the peak deposition altitude was calculated to be 42 km, but the resulting bremsstrahlung deposition peaked at 25 km. This has implications for crew and passenger safety, especially with the growth of the space tourism industry. A survey of results covering the 1-100 MeV spectrum for the three altitude ranges of interest will be presented.

  5. Weed suppression greatly increased by plant diversity in intensively managed grasslands: A continental-scale experiment.

    Science.gov (United States)

    Connolly, John; Sebastià, Maria-Teresa; Kirwan, Laura; Finn, John Anthony; Llurba, Rosa; Suter, Matthias; Collins, Rosemary P; Porqueddu, Claudio; Helgadóttir, Áslaug; Baadshaug, Ole H; Bélanger, Gilles; Black, Alistair; Brophy, Caroline; Čop, Jure; Dalmannsdóttir, Sigridur; Delgado, Ignacio; Elgersma, Anjo; Fothergill, Michael; Frankow-Lindberg, Bodil E; Ghesquiere, An; Golinski, Piotr; Grieu, Philippe; Gustavsson, Anne-Maj; Höglind, Mats; Huguenin-Elie, Olivier; Jørgensen, Marit; Kadziuliene, Zydre; Lunnan, Tor; Nykanen-Kurki, Paivi; Ribas, Angela; Taube, Friedhelm; Thumm, Ulrich; De Vliegher, Alex; Lüscher, Andreas

    2018-03-01

    Grassland diversity can support sustainable intensification of grassland production through increased yields, reduced inputs and limited weed invasion. We report the effects of diversity on weed suppression from 3 years of a 31-site continental-scale field experiment.At each site, 15 grassland communities comprising four monocultures and 11 four-species mixtures based on a wide range of species' proportions were sown at two densities and managed by cutting. Forage species were selected according to two crossed functional traits, "method of nitrogen acquisition" and "pattern of temporal development".Across sites, years and sown densities, annual weed biomass in mixtures and monocultures was 0.5 and 2.0 t  DM ha -1 (7% and 33% of total biomass respectively). Over 95% of mixtures had weed biomass lower than the average of monocultures, and in two-thirds of cases, lower than in the most suppressive monoculture (transgressive suppression). Suppression was significantly transgressive for 58% of site-years. Transgressive suppression by mixtures was maintained across years, independent of site productivity.Based on models, average weed biomass in mixture over the whole experiment was 52% less (95% confidence interval: 30%-75%) than in the most suppressive monoculture. Transgressive suppression of weed biomass was significant at each year across all mixtures and for each mixture.Weed biomass was consistently low across all mixtures and years and was in some cases significantly but not largely different from that in the equiproportional mixture. The average variability (standard deviation) of annual weed biomass within a site was much lower for mixtures (0.42) than for monocultures (1.77). Synthesis and applications . Weed invasion can be diminished through a combination of forage species selected for complementarity and persistence traits in systems designed to reduce reliance on fertiliser nitrogen. In this study, effects of diversity on weed suppression were

  6. Diamonds in the rough: a strong case for the inclusion of weak-intensity X-ray diffraction data

    International Nuclear Information System (INIS)

    Wang, Jimin; Wing, Richard A.

    2014-01-01

    Here, new evidence is provided to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry averaging. Overwhelming evidence exists to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps improve the refinement of atomic models by imposing strong constraints on individual and overall temperature B factors and thus the quality of crystal structures. Some researchers consider these data to be of little value and opt to discard them during data processing, particularly at medium and low resolution, at which individual B factors of atomic models cannot be refined. Here, new evidence is provided to show that the inclusion of these data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry (NCS) averaging. Using electron-density correlation coefficients as criteria, the resolution of data has successfully been extended from 3.1 to 2.5 Å resolution with redundancy-independent merging R factors from below 100% to about 310%. It is further demonstrated that phase information can be fully extracted from observed amplitudes through de novo NCS averaging. Averaging starts with uniform density inside double-shelled spherical masks and NCS matrices that are derived from bound heavy-atom clusters at the vertices of cuboctahedrally symmetric protein particles

  7. A comparison of theoretical and solar-flare intensity ratios for the Fe XIX X-ray lines

    International Nuclear Information System (INIS)

    Bhatia, A.K.; Mason, H.E.; Fawcett, B.C.; Phillips, K.J.H.

    1989-04-01

    Atomic data consisting of energy levels, g f-values and wavelengths are presented for the Fe XIX 2s 2 2p 4 -2s 2 2p 3 3s, 2s 2 2p 3 3d arrays that give rise to lines in solar flare and active-region X-ray spectra. Collision strengths and theoretical intensity ratios are given for the 2s 2 2p 4 -2s 2 2p 3 3d lines, which occur in the 13.2-14.3 A range. Solar spectra in this range include a large number of other intense lines, notably those due to He-like Ne (Ne IX). Although the Ne IX lines are potentially the most useful indicators of electron density in solar X-ray spectra, blending with the Fe XIX lines has been a major problem for previous analyses. Comparison of observed spectra with those calculated from the Fe XIX atomic data presented here and Ne IX lines from other work indicates that there is generally good agreement. We use the calculated Fe XIX and Ne IX line spectra and several observed spectra during a flare previously analysed to estimate electron density from Ne IX line ratios, thus for the first time properly taking into account blends with Fe XIX lines. (author)

  8. Head and neck intensity modulated radiation therapy leads to an increase of opportunistic oral pathogens

    NARCIS (Netherlands)

    Schuurhuis, Jennifer M.; Stokman, Monique A.; Witjes, Max J. H.; Langendijk, Johannes A.; van Winkelhoff, Arie J.; Vissink, Arjan; Spijkervet, Frederik K. L.

    Objectives: The introduction of intensity modulated radiation therapy (IMRT) has led to new possibilities in the treatment of head and neck cancer (HNC). Limited information is available on how this more advanced radiation technique affects the oral microflora. In a prospective study we assessed the

  9. Generalization of Conditioned Fear along a Dimension of Increasing Fear Intensity

    Science.gov (United States)

    Dunsmoor, Joseph E.; Mitroff, Stephen R.; LaBar, Kevin S.

    2009-01-01

    The present study investigated the extent to which fear generalization in humans is determined by the amount of fear intensity in nonconditioned stimuli relative to a perceptually similar conditioned stimulus. Stimuli consisted of graded emotionally expressive faces of the same identity morphed between neutral and fearful endpoints. Two…

  10. Nutritional enrichment increases courtship intensity and improves mating success in male spiders

    DEFF Research Database (Denmark)

    Lomborg, Johannes Peter; Toft, Søren

    2009-01-01

    status (enriched or deficient) and that courtship intensity predicts mating success in males of the same nutritional status. We used wolf spiders, Pardosa prativaga, which have an elaborate display of courtship behaviors, including encircling, palp vibrations, abdomen vibrations, hopping, etc. Viability...

  11. Effect of powder sample granularity on fluorescent intensity and on thermal parameters in x-ray diffraction Rietveld analysis

    International Nuclear Information System (INIS)

    Sparks, C.J.; Specht, E.D.; Ice, G.E.; Kumar, R.; Zschack, P.; Shiraishi, T.; Hisatsune, K.

    1991-01-01

    The effect of sample granularity on diffracted x-ray intensity was evaluated by measuring the 2θ dependence of x-ray fluorescence from various samples. Measurements were made in the symmetric geometry on samples ranging from single crystals to highly absorbing coarse powders. A characteristic shape for the absorption correction was observed. A demonstration of the sensitivity of Rietveld refined site occupation parameters is made on CuAu and Cu 50 Au 44 Ni 6 alloys refined with and without granularity corrections. These alloys provide a good example of the effect of granularity due to their large linear x-ray absorption coefficients. Sample granularity and refined thermal parameters obtained from the Rietveld analysis were found to be correlated. Without a granularity correction, the refined thermal parameters are too low and can actually become negative in an attempt to compensate for granularity. A general shape for granularity correction can be included in refinement procedures. If no granularity correction is included, data should be restricted to above 30 degrees 2θ, and thermal parameters should be ignored unless extreme precautions are taken to produce >5 μm particles and high packing densities

  12. Multilayered samples reconstructed by measuring Kα/Kβ or Lα/Lβ X-ray intensity ratios by EDXRF

    Science.gov (United States)

    Cesareo, Roberto; de Assis, Joaquim T.; Roldán, Clodoaldo; Bustamante, Angel D.; Brunetti, Antonio; Schiavon, Nick

    2013-10-01

    In this paper a general method based on energy-dispersive X-ray fluorescence (EDXRF) analysis has been tested to assess its possible use as a tool to reconstruct the structure and determine the thickness of two and/or multi-layered materials. The method utilizes the X-ray intensity ratios of Kα/Kβ or Lα/Lβ peaks (or the ratio of these peaks) for selected elements present in multi-layered objects of various materials (Au alloys, gilded Cu, gilded Ag, gilded Pb, Ag-Au Tumbaga, stone surfaces with protective treatments, Zn or Nickel plating on metals). Results show that, in the case of multi-layered samples, a correct calculation of the peak ratio (Kα /Kβ and/or Lα/Lβ) of relevant elements from energy-dispersive X-ray fluorescence spectra, can provide important information in assessing the exact location of each layer and for calculating its thickness. The methodological approach shown may have important applications not only in materials science but also when dealing with the conservation and restoration of multi-layered cultural heritage objects where the use of a Non-Destructive techniques to determine slight chemical and thickness variations in the layered structure is often of paramount importance to achieve the best results.

  13. Conceptual Design of Dielectric Accelerating Structures for Intense Neutron and Monochromatic X-ray Sources

    Science.gov (United States)

    Blanovsky, Anatoly

    2004-12-01

    Bright compact photon sources, which utilize electron beam interaction with periodic structures, may benefit a broad range of medical, industrial and scientific applications. A class of dielectric-loaded periodic structures for hard and soft X-ray production has been proposed that would provide a high accelerating gradient when excited by an external RF and/or primary electron beam. Target-distributed accelerators (TDA), in which an additional electric field compensates for lost beam energy in internal targets, have been shown to provide the necessary means to drive a high flux subcritical reactor (HFSR) for nuclear waste transmutation. The TDA may also be suitable for positron and nuclear isomer production, X-ray lithography and monochromatic computer tomography. One of the early assumptions of the theory of dielectric wake-field acceleration was that, in electrodynamics, the vector potential was proportional to the scalar potential. The analysis takes into consideration a wide range of TDA design aspects including the wave model of observed phenomena, a layered compound separated by a Van der Waals gap and a compact energy source based on fission electric cells (FEC) with a multistage collector. The FEC is a high-voltage power source that directly converts the kinetic energy of the fission fragments into electrical potential of about 2MV.

  14. Few-body Studies at the High Intensity γ-Ray Source (HIγS

    Directory of Open Access Journals (Sweden)

    Weller H.R.

    2010-04-01

    Full Text Available The HIγS facility is making it possible to perform studies of few body systems at a new level of accuracy and precision. A study of the photodisintegration of the deuteron using 100% linearly polarized beams at 14 and 16 MeV has determined the splittings of the three p-wave amplitudes involved in this process for the first time. These results show that the relativistic contributions, which when included in the theory lead to a positive value of the GDH integrand above 8 MeV, are valid. The near threshold data on the photodisintegration of the deuteron provide results which are used to extract the forward spin-polarizability of the deuteron for the first time. The experimental value is in good agreement with a recent effective field theory calculation. Measurements of the absolute differential cross section of the 3He(γ,npp reaction have been completed at three γ-ray energies. The measurements were made at incident γ-ray energies of 12.8, 13.5, and 14.7 MeV. It has been found that the shape of the outgoing neutron energy distribution at a given scattering angle at 12.8 MeV disagrees with current theoretical predictions. At these energies, the shape is consistent with a phase-space-only shape. At the higher energies, the measurements agree with theory.

  15. Gamma-ray dose rate increase at rainfall events and their air-mass origins

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2007-01-01

    The environmental γ-ray dose rate and precipitation rates were measured at our institute, in Rokkasho, Aomori, Japan. We analyzed 425 rainfall events in which the precipitation rate was over 0.5 mm from April through November during the years 2003 to 2005. Backward trajectories for 5 d starting from 1000 m above Rokkasho at the time of the maximum dose rate in a rainfall event, were calculated by using the HYSPLIT model of the NOAA Air Resources Laboratory. The trajectories for 5 d were classified by visual inspection according to the passage areas; Pacific Ocean, Asian Continent and Japan Islands. The increase of cumulative environmental γ-ray dose during a rainfall event was plotted against the precipitation in the event, and their relationship was separately examined according to the air-mass passage area, i.e. origin of the air-mass. Our results showed that the origin of air-mass was an important factor affecting the increase of environmental γ-ray dose rate by rainfall. (author)

  16. Charge transfer in dissociating iodomethane and fluoromethane molecules ionized by intense femtosecond X-ray pulses

    Directory of Open Access Journals (Sweden)

    Rebecca Boll

    2016-07-01

    Full Text Available Ultrafast electron transfer in dissociating iodomethane and fluoromethane molecules was studied at the Linac Coherent Light Source free-electron laser using an ultraviolet-pump, X-ray-probe scheme. The results for both molecules are discussed with respect to the nature of their UV excitation and different chemical properties. Signatures of long-distance intramolecular charge transfer are observed for both species, and a quantitative analysis of its distance dependence in iodomethane is carried out for charge states up to I21+. The reconstructed critical distances for electron transfer are in good agreement with a classical over-the-barrier model and with an earlier experiment employing a near-infrared pump pulse.

  17. Measurement of the noise components in the medical x-ray intensity pattern due to overlaying nonrecognizable structures

    Science.gov (United States)

    Tischenko, Oleg; Hoeschen, Christoph; Effenberger, Olaf; Reissberg, Steffen; Buhr, Egbert; Doehring, Wilfried

    2003-06-01

    There are many aspects that influence and deteriorate the detection of pathologies in X-ray images. Some of those are due to effects taking place in the stage of forming the X-ray intensity pattern in front of the x-ray detector. These can be described as motion blurring, depth blurring, anatomical background, scatter noise and structural noise. Structural noise results from an overlapping of fine irrelevant anatomical structures. A method for measuring the combined effect of structural noise and scatter noise was developed and will be presented in this paper. This method is based on the consideration that within a pair of projections created after rotation of the object with a small angle (which is within the typical uncertainty in positioning the patient) both images would show the same relevant structures whereas the projection of the fine overlapping structures will appear quite differently in the two images. To demonstrate the method two X-ray radiographs of a lung phantom were produced. The second radiograph was achieved after rotating the lung by an angle of about 3. Dyadic wavelet representations of both images were regarded. For each value of the wavelet scale parameter the corresponding pair of approximations was matched using the cross correlation matching technique. The homologous regions of approximations were extracted. The image containing only those structures that appear in both images simultaneously was then reconstructed from the wavelet coefficients corresponding to the homologous regions. The difference between one of the original images and the noise-reduced image contains the structural noise and the scatter noise.

  18. An application of statistical adjustment of data to the energetic solar cosmic ray increase of August 7, 1972

    International Nuclear Information System (INIS)

    Komori, H.

    1975-01-01

    Data of five minute intervals of the neutron intensity from twelve cosmic ray stations were utilized for this application. Five source parameters; amplitude a, latitude lambdasub(s), longitude PHIsub(s), power law exponent γ in spectral representation and power law exponent n of angular spread have been determined by the least-square method of Deming. (orig./WBU) [de

  19. Combined exposure of ELF magnetic fields and X-rays increased mutant yields compared with X-rays alone in pTN89 plasmids

    International Nuclear Information System (INIS)

    Koyama, Shin; Nakahara, Takehisa; Sakurai, Tomonori; Komatsubara, Yoshiki; Miyakoshi, Junji; Isozumi, Yasuhito

    2005-01-01

    We have examined mutations in the supF gene carried by pTN89 plasmids in Escherichia coli (E. coli) to examine the effects of extremely low frequency magnetic fields (ELFMFs) and/or X-rays to the plasmids. The plasmids were subjected to sham exposure or exposed to an ELFMF (5 mT), with or without X-ray irradiation (10 Gy). For the combined treatments, exposure to the ELFMF was immediately before or after X-ray irradiation. The mutant fractions were 0.94 x 10 -5 for X-rays alone, 1.58 x 10 -5 for an ELFMF followed by X-rays, and 3.64 x 10 -5 for X-rays followed by an ELFMF. Increased mutant fraction was not detected following exposure to a magnetic field alone, or after sham exposure. The mutant fraction for X-rays followed by an ELFMF was significantly higher than those of other treatments. Sequence analysis of the supF mutant plasmids revealed that base substitutions were dominant on exposure to X-rays alone and X-rays plus an ELFMF. Several types of deletions were detected in only the combined treatments, but not with X-rays alone. We could not find any mutant colonies in sham irradiated and an ELFMF alone treatment, but exposure to ELFMFs immediately before or after X-ray irradiation may enhance the mutations. Our results indicate that an ELFMF increases mutation and alters the spectrum of mutations. (author)

  20. Threshold of musculoskeletal pain intensity for increased risk of long-term sickness absence among female healthcare workers in eldercare.

    Directory of Open Access Journals (Sweden)

    Lars L Andersen

    Full Text Available PURPOSE: Musculoskeletal disorders increase the risk for absenteeism and work disability. However, the threshold when musculoskeletal pain intensity significantly increases the risk of sickness absence among different occupations is unknown. This study estimates the risk for long-term sickness absence (LTSA from different pain intensities in the low back, neck/shoulder and knees among female healthcare workers in eldercare. METHODS: Prospective cohort study among 8,732 Danish female healthcare workers responding to a questionnaire in 2004-2005, and subsequently followed for one year in a national register of social transfer payments (DREAM. Using Cox regression hazard ratio (HR analysis we modeled risk estimates of pain intensities on a scale from 0-9 (reference 0, where 0 is no pain and 9 is worst imaginable pain in the low back, neck/shoulders and knees during the last three months for onset of LTSA (receiving sickness absence compensation for at least eight consecutive weeks during one-year follow-up. RESULTS: During follow-up, the 12-month prevalence of LTSA was 6.3%. With adjustment for age, BMI, smoking and leisure physical activity, the thresholds of pain intensities significantly increasing risk of LTSA for the low back (HR 1.44 [95%CI 1.07-1.93], neck/shoulders (HR 1.47 [95%CI 1.10-1.96] and knees (HR 1.43 [95%CI 1.06-1.93] were 5, 4 and 3 (scale 0-9, respectively, referencing pain intensity of 0. CONCLUSION: The threshold of pain intensity significantly increasing the risk for LTSA among female healthcare workers varies across body regions, with knee pain having the lowest threshold. This knowledge may be used in the prevention of LTSA among health care workers.

  1. Wire number doubling in plasma-shell regime increases z-accelerator x-ray power

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T.W.L.; Spielman, R.B.; Chandler, G.A. [and others

    1997-11-01

    Doubling the number of tungsten wires from 120 to 240, keeping the mass fixed, increased the radiated x-ray power relative to the electrical power at the insulator stack of the z accelerator by (40{+-}20)% for 8.75- and 20-mm-radii z-pinch wire arrays. Radiation-magneto-hydrodynamic calculations suggest that the arrays were operating in the {open_quotes}plasma shell{close_quotes} regime, where the plasmas generated by the individual wires merge prior to the inward implosion of the entire array.

  2. Wire number doubling in plasma-shell regime increases z-accelerator x-ray power

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Spielman, R.B.; Chandler, G.A.

    1997-11-01

    Doubling the number of tungsten wires from 120 to 240, keeping the mass fixed, increased the radiated x-ray power relative to the electrical power at the insulator stack of the z accelerator by (40±20)% for 8.75- and 20-mm-radii z-pinch wire arrays. Radiation-magneto-hydrodynamic calculations suggest that the arrays were operating in the 'plasma shell' regime, where the plasmas generated by the individual wires merge prior to the inward implosion of the entire array

  3. Wire number doubling in plasma-shell regime increases Z-accelerator X-ray power

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Spielman, R.B.; Chandler, G.A.

    1997-01-01

    Doubling the number of tungsten wires from 120 to 240, keeping the mass fixed, increased the radiated x-ray power relative to the electrical power at the insulator stack of the z accelerator by (40 ± 20)% for 8.75- and 20-mm-radii z-pinch wire arrays. Radiation-magneto-hydrodynamic calculations suggest that the arrays were operating in the plasma shell regime, where the plasma generated by the individual wires merge prior to the inward implosion of the entire array

  4. Wire number doubling in plasma-shell regime increases Z-accelerator X-ray power

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T.W.L.; Spielman, R.B.; Chandler, G.A. [and others

    1997-12-01

    Doubling the number of tungsten wires from 120 to 240, keeping the mass fixed, increased the radiated x-ray power relative to the electrical power at the insulator stack of the z accelerator by (40 {+-} 20)% for 8.75- and 20-mm-radii z-pinch wire arrays. Radiation-magneto-hydrodynamic calculations suggest that the arrays were operating in the plasma shell regime, where the plasma generated by the individual wires merge prior to the inward implosion of the entire array.

  5. Magnetic orientation in birds: non-compass responses under monochromatic light of increased intensity.

    Science.gov (United States)

    Wiltschko, Wolfgang; Munro, Ursula; Ford, Hugh; Wiltschko, Roswitha

    2003-10-22

    Migratory Australian silvereyes (Zosterops lateralis) were tested under monochromatic light at wavelengths of 424 nm blue and 565 nm green. At a low light level of 7 x 10(15) quanta m(-2) s(-1) in the local geomagnetic field, the birds preferred their seasonally appropriate southern migratory direction under both wavelengths. Their reversal of headings when the vertical component of the magnetic field was inverted indicated normal use of the avian inclination compass. A higher light intensity of 43 x 10(15) quanta m(-2) s(-1), however, caused a fundamental change in behaviour: under bright blue, the silvereyes showed an axial tendency along the east-west axis; under bright green, they showed a unimodal preference of a west-northwesterly direction that followed a shift in magnetic north, but was not reversed by inverting the vertical component of the magnetic field. Hence it is not based on the inclination compass. The change in behaviour at higher light intensities suggests a complex interaction between at least two receptors. The polar nature of the response under bright green cannot be explained by the current models of light-dependent magnetoreception and will lead to new considerations on these receptive processes.

  6. The connection of the interplanetary magnetic field turbulence and rigidity spectrum of Forbush decrease of the galactic cosmic ray intensity

    International Nuclear Information System (INIS)

    Wawrzynczak, A; Alania, M V

    2015-01-01

    We analyze the temporal changes in the rigidity spectrum of Forbush decrease (Fd) of the galactic cosmic ray (GCR) intensity observed in November 2004. We compute the rigidity spectrum in two energy ranges based on the daily data from the worldwide network of neutron monitors and Nagoya ground muon telescope. We demonstrate that the changes in the rigidity spectrum of Fd are linked to the evolution/decay of the interplanetary magnetic field (IMF) turbulence during various phases of the Fd. We analyze the time-evolution of the state of the turbulence of the IMF in various frequency ranges during the Fd. Performed analysis show that the decrease of the exponent ν of the Power Spectral Density (PSD ∝ f −ν , where f is frequency) of the IMF turbulence with decreasing frequency lead to the soft rigidity spectrum of Fd for GCR particles with relatively higher energies. (paper)

  7. Generalized atomic processes for interaction of intense femtosecond XUV- and X-ray radiation with solids

    International Nuclear Information System (INIS)

    Deschaud, B.; Peyrusse, O.; Rosmej, F.B.

    2014-01-01

    Generalized atomic processes are proposed to establish a consistent description from the free-atom approach to the heated and even up to the cold solid. It is based on a rigorous introduction of the Fermi-Dirac statistics, Pauli blocking factors and on the respect of the principle of detailed balance via the introduction of direct and inverse processes. A probability formalism driven by the degeneracy of the free electrons enables to establish a link of atomic rates valid from the heated atom up to the cold solid. This allows to describe photoionization processes in atomic population kinetics and subsequent solid matter heating on a femtosecond time scale. The Auger effect is linked to the 3-body recombination via a generalized 3-body recombination that is identified as a key mechanism, along with the collisional ionization, that follows energy deposition by photoionization of inner shells when short, intense and high-energy radiation interacts with matter. Detailed simulations are carried out for aluminum that highlight the importance of the generalized approach. (authors)

  8. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, M.; Sakamoto, S.; Ishii, K. [Division of Neuroimaging Research, Hyogo Institute for Aging Brain and Cognitive Disorders (Japan); Imamura, T.; Kazui, H.; Mori, E. [Division of Clinical Neurosciences, Hyogo Institute for Aging Brain and Cognitive Disorders, Hyogo (Japan)

    2002-03-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  9. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Matsui, M.; Sakamoto, S.; Ishii, K.; Imamura, T.; Kazui, H.; Mori, E.

    2002-01-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  10. Increased Protein Requirements in Female Athletes after Variable-Intensity Exercise.

    Science.gov (United States)

    Wooding, Denise J; Packer, Jeff E; Kato, Hiroyuki; West, Daniel W D; Courtney-Martin, Glenda; Pencharz, Paul B; Moore, Daniel R

    2017-11-01

    Protein requirements are primarily studied in the context of resistance or endurance exercise with little research devoted to variable-intensity intermittent exercise characteristic of many team sports. Further, female populations are underrepresented in dietary sports science studies. We aimed to determine a dietary protein requirement in active females performing variable-intensity intermittent exercise using the indicator amino acid oxidation (IAAO) method. We hypothesized that these requirements would be greater than current IAAO-derived estimates in nonactive adult males. Six females (21.2 ± 0.8 yr, 68.8 ± 4.1 kg, 47.1 ± 1.2 mL O2·kg·min; mean ± SE) completed five to seven metabolic trials during the luteal phase of the menstrual cycle. Participants performed a modified Loughborough Intermittent Shuttle Test before consuming eight hourly mixed meals providing the test protein intake (0.2-2.66 g·kg·d), 6 g·kg·d CHO and sufficient energy for resting and exercise-induced energy expenditure. Protein was provided as crystalline amino acid modeling egg protein with [C]phenylalanine as the indicator amino acid. Phenylalanine turnover (Q) was determined from urinary [C]phenylalanine enrichment. Breath CO2 excretion (FCO2) was analyzed using mixed effects biphase linear regression with the breakpoint and upper 95% confidence interval approximating the estimated average requirement and recommended dietary allowance, respectively. Protein intake had no effect on Q (68.7 ± 7.3 μmol·kg·h; mean ± SE). FCO2 displayed a robust biphase response (R = 0.66) with an estimated average requirement of 1.41 g·kg·d and recommended dietary allowance of 1.71 g·kg·d. The protein requirement estimate of 1.41 and 1.71 g·kg·d for females performing variable-intensity intermittent exercise is greater than the IAAO-derived estimates of adult males (0.93 and 1.2 g·kg·d) and at the upper range of the American College of Sports Medicine athlete recommendations (1.2-2.0 g·kg·d).

  11. Time-resolved x-ray diffraction studies on the intensity changes of the 5.9 and 5.1 nm actin layer lines from frog skeletal muscle during an isometric tetanus using synchrotron radiation

    International Nuclear Information System (INIS)

    Wakabayashi, K.; Tanaka, H.; Amemiya, Y.; Fujishima, A.; Kobayashi, T.; Hamanaka, T.; Sugi, H.; Mitsui, T.

    1985-01-01

    Time-resolved x-ray diffraction studies have been made on the 5.9- and 5.1-nm actin layer lines from frog skeletal muscles during an isometric tetanus at 6 degrees C, using synchrotron radiation. The integrated intensities of these actin layer lines were found to increase during a tetanus by 30-50% for the 5.9-nm reflection and approximately 70% for the 5.1-nm reflection of the resting values. The intensity increase of both reflections was greater than that taking place in the transition from rest to rigor state. The intensity change of the 5.9-nm reflection preceded those of the myosin 42.9-nm off-meridional reflection and of the equatorial reflections, as well as the isometric tension development. The intensity profile of the 5.9-nm layer line during contraction was found to be different from that observed in the rigor state

  12. Magnified Sediment Export of Small Mountainous Rivers in Taiwan: Chain Reactions from Increased Rainfall Intensity under Global Warming.

    Science.gov (United States)

    Lee, Tsung-Yu; Huang, Jr-Chuan; Lee, Jun-Yi; Jien, Shih-Hao; Zehetner, Franz; Kao, Shuh-Ji

    2015-01-01

    Fluvial sediment export from small mountainous rivers in Oceania has global biogeochemical significance affecting the turnover rate and export of terrestrial carbon, which might be speeding up at the recognized conditions of increased rainfall intensity. In this study, the historical runoff and sediment export from 16 major rivers in Taiwan are investigated and separated into an early stage (1970-1989) and a recent stage (1990-2010) to illustrate the changes of both runoff and sediment export. The mean daily sediment export from Taiwan Island in the recent stage significantly increased by >80% with subtle increase in daily runoff, indicating more sediment being delivered to the ocean per unit of runoff in the recent stage. The medians of the runoff depth and sediment yield extremes (99.0-99.9 percentiles) among the 16 rivers increased by 6.5%-37% and 62%-94%, respectively, reflecting the disproportionately magnified response of sediment export to the increased runoff. Taiwan is facing increasing event rainfall intensity which has resulted in chain reactions on magnified runoff and sediment export responses. As the globe is warming, rainfall extremes, which are proved to be temperature-dependent, very likely intensify runoff and trigger more sediment associated hazards. Such impacts might occur globally because significant increases of high-intensity precipitation have been observed not only in Taiwan but over most land areas of the globe.

  13. Severe fire weather and intensive forest management increase fire severity in a multi-ownership landscape.

    Science.gov (United States)

    Zald, Harold S J; Dunn, Christopher J

    2018-04-26

    Many studies have examined how fuels, topography, climate, and fire weather influence fire severity. Less is known about how different forest management practices influence fire severity in multi-owner landscapes, despite costly and controversial suppression of wildfires that do not acknowledge ownership boundaries. In 2013, the Douglas Complex burned over 19,000 ha of Oregon & California Railroad (O&C) lands in Southwestern Oregon, USA. O&C lands are composed of a checkerboard of private industrial and federal forestland (Bureau of Land Management, BLM) with contrasting management objectives, providing a unique experimental landscape to understand how different management practices influence wildfire severity. Leveraging Landsat based estimates of fire severity (Relative differenced Normalized Burn Ratio, RdNBR) and geospatial data on fire progression, weather, topography, pre-fire forest conditions, and land ownership, we asked (1) what is the relative importance of different variables driving fire severity, and (2) is intensive plantation forestry associated with higher fire severity? Using Random Forest ensemble machine learning, we found daily fire weather was the most important predictor of fire severity, followed by stand age and ownership, followed by topographic features. Estimates of pre-fire forest biomass were not an important predictor of fire severity. Adjusting for all other predictor variables in a general least squares model incorporating spatial autocorrelation, mean predicted RdNBR was higher on private industrial forests (RdNBR 521.85 ± 18.67 [mean ± SE]) vs. BLM forests (398.87 ± 18.23) with a much greater proportion of older forests. Our findings suggest intensive plantation forestry characterized by young forests and spatially homogenized fuels, rather than pre-fire biomass, were significant drivers of wildfire severity. This has implications for perceptions of wildfire risk, shared fire management responsibilities, and developing

  14. X-ray diffraction patterns and diffracted intensity of Kα spectral lines of He-like ions

    Science.gov (United States)

    Goyal, Arun; Khatri, Indu; Singh, A. K.; Sharma, Rinku; Mohan, Man

    2017-09-01

    In the present paper, we have calculated fine-structure energy levels related to the configurations 1s2s, 1s2p, 1s3s and 1s3p by employing GRASP2K code. We have also computed radiative data for transitions from 1s2p 1 P1o, 1s2p 3 P2o, 1s2p 3 P1o and 1s2s 3S1 to the ground state 1s2. We have made comparisons of our presented energy levels and transition wavelengths with available results compiled by NIST and good agreement is achieved. We have also provided X-ray diffraction (XRD) patterns of Kα spectral lines, namely w, x, y and z of Cu XXVIII, Kr XXXV and Mo with diffraction angle and maximum diffracted intensity which is not published elsewhere in the literature. We believe that our presented results may be beneficial in determination of the order parameter, X-ray crystallography, solid-state drug analysis, forensic science, geological and medical applications.

  15. High-intensity x-ray holography: an approach to high-resolution snapshot imaging of biological specimens

    International Nuclear Information System (INIS)

    Solem, J.C.

    1982-08-01

    The crucial physical and technological issues pertaining to the holographic imaging of biological structures with a short-pulse, high-intensity, high-quantum-energy laser were examined. The limitations of x-ray optics are discussed. Alternative holographic techniques were considered, and it was concluded that far-field Fresnel transform holography (Fraunhofer holography) using a photoresist recording surface is most tractable with near term technology. The hydrodynamic expansion of inhomogeneities within the specimen is discussed. It is shown that expansion is the major source of image blurring. Analytic expressions were derived for the explosion of protein concentrations in an x-ray transparent cytoplasm, compared with numerical calculations, and corrections derived to account for the competitive transport processes by which these inhomogeneities lose energy. It is concluded that for the near term Fresnel transform holography, particularly, far-field or Fraunhofer holography, is more practical than Fourier transform holography. Of the alternative fine grain recording media for use with Fresnel transform holography, a photo-resist is most attractive. For best resolution, exposure times must be limited to a few picoseconds, and this calls for investigation of mechanisms to shutter the laser or gate the recording surface. The best contrast ratio between the nitrogen-bearing polymers (protein and the nucleic acids) and water is between the K-edges of oxygen and nitrogen

  16. High-intensity x-ray holography: an approach to high-resolution snapshot imaging of biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Solem, J.C.

    1982-08-01

    The crucial physical and technological issues pertaining to the holographic imaging of biological structures with a short-pulse, high-intensity, high-quantum-energy laser were examined. The limitations of x-ray optics are discussed. Alternative holographic techniques were considered, and it was concluded that far-field Fresnel transform holography (Fraunhofer holography) using a photoresist recording surface is most tractable with near term technology. The hydrodynamic expansion of inhomogeneities within the specimen is discussed. It is shown that expansion is the major source of image blurring. Analytic expressions were derived for the explosion of protein concentrations in an x-ray transparent cytoplasm, compared with numerical calculations, and corrections derived to account for the competitive transport processes by which these inhomogeneities lose energy. It is concluded that for the near term Fresnel transform holography, particularly, far-field or Fraunhofer holography, is more practical than Fourier transform holography. Of the alternative fine grain recording media for use with Fresnel transform holography, a photo-resist is most attractive. For best resolution, exposure times must be limited to a few picoseconds, and this calls for investigation of mechanisms to shutter the laser or gate the recording surface. The best contrast ratio between the nitrogen-bearing polymers (protein and the nucleic acids) and water is between the K-edges of oxygen and nitrogen.

  17. Investigation of the interaction of high intensity laser light with solids and hot plasma using X-ray spectroscopic technique

    International Nuclear Information System (INIS)

    Zigler, A.

    1978-06-01

    This work investigates the properties of high power laser-produced plasmas by developing and applying x-ray spectroscopic methods which utilize spatial resolution. The shadow techniques which were developed in this work yield a high spatial resolution of 5-15μm together with an adequate X-ray spectral resolution for single shots of laser power flux of 2.10 13 W/cm -2 . The intensity distribution in the source is calculated from the partial shadow by numerical differentiation. The main advantage of the present method is the ability to obtain spatial information simultaneously for strong and weak spectral lines for a single shot of medium power laser. Plasma parameters were derived from H-like and He-like lines and their inner-shell satellites, which were obtained from Mg, Al and Si targets. Using shadow techniques, the sizes of the emitting regions of the various spectral lines were measured; the spatial variation of the ionization stage, the electron temperature and density were investigated. A constant electron temperature of (250+-50)eV and electron density scale-length of about 50μm were derived for an expanding plasma. An experimental investigation of the possible origin and the mechanisms responsible for the Ksub(α) radiation in laser-produced plasma was carried out. It is shown that the Ksub(α) radiation was generated by fast suprathermal electrons and originated inside the target behind the interaction zone of the shock and heat waves. Energy penetration depth and hot plasma expansion were tested by using multilayer targets, thin foils and achieving a two-dimensional spatially resolved X-ray Al spectrum. (B.G.)

  18. Annealing bounds to prevent further Charge Transfer Inefficiency increase of the Chandra X-ray CCDs

    Energy Technology Data Exchange (ETDEWEB)

    Monmeyran, Corentin, E-mail: comonmey@mit.edu [Department of Materials Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Patel, Neil S., E-mail: neilp@mit.edu [Department of Materials Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Bautz, Mark W., E-mail: mwb@space.mit.edu [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Grant, Catherine E., E-mail: cgrant@space.mit.edu [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Prigozhin, Gregory Y., E-mail: gyp@space.mit.edu [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Agarwal, Anuradha, E-mail: anu@mit.edu [Microphotonics Center, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Kimerling, Lionel C., E-mail: lckim@mit.edu [Department of Materials Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Microphotonics Center, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States)

    2016-12-15

    After the front-illuminated CCDs on board the X-ray telescope Chandra were damaged by radiation after launch, it was decided to anneal them in an effort to remove the defects introduced by the irradiation. The annealing led to an unexpected increase of the Charge Transfer Inefficiency (CTI). The performance degradation is attributed to point defect interactions in the devices. Specifically, the annealing at 30 °C activated the diffusion of the main interstitial defect in the device, the carbon interstitial, which led to its association with a substitutional impurity, ultimately resulting in a stable and electrically active defect state. Because the formation reaction of this carbon interstitial and substitutional impurity associate is diffusion limited, we recommend a higher upper bound for the annealing temperature and duration of any future CCD anneals, that of −50 °C for one day or −60 °C for a week, to prevent further CTI increase.

  19. The day-night variation of cosmic rays intensity at sea level under the influence of meteorological fronts and troughs

    International Nuclear Information System (INIS)

    Mok, H.M.; Cheng, K.M.

    2000-01-01

    The day-night variation of cosmic rays (CR) intensity at sea level has been observed by a simple G-M counter telescope. We perform two 5 hours counting during the day and the night and find that the pattern of variation is closely related to the atmospheric disturbance. The normal pattern shows that the day counts is a few percents lower than that of the night counts. This can be simply explained by the temperature effect. But when our observation station is being affected by a meteorological front or trough, a reversal occurs. At times the reversal pattern occurs even up to a few days ahead the formation of the troughs at a few hundred kilometers away. Such a reversal may lasts for a few days until the influence of the front or trough has significantly weakened. This effect also overrides the barometric effect, except when there is a sharp change of air pressure, such as during the approach of a tropical cyclone. Our further investigation shows that the pattern of variation may be negatively correlated to the altitude of the 0degC level in the atmosphere. A 150 m upward shift of the 0degC level reduces the CR intensity by about 3-4%. Our postulation is that this variation of CR intensity is related to the relativistic effect of the muon decay, and is an indication of the height of the mid-level pressure distribution. The phenomenon should be further investigated for possible application in weather forecasting and better understanding of the phenomenon could be of use in differentiating the atmospheric effect and the solar effects in CR data. (author)

  20. The additional dose to radiosensitive organs caused by using under-collimated X-ray beams in neonatal intensive care radiography

    International Nuclear Information System (INIS)

    Datz, H.; Ben-Shlomo, A.; Margaliot, M.; Bader, D.; Sadetzki, S.; Juster-Reicher, A.; Marks, K.; Smolkin, T.; Zangen, S.

    2008-01-01

    Radiographic technique and exposure parameters were recorded in five Israeli Neonatal Intensive Care Units for chest, abdomen and both chest and abdomen X-ray examinations. Equivalent dose and effective dose values were calculated according to actual examination field size borders and proper technique field size recommendations using PCXMC, a PC-based Monte Carlo program. Exposure of larger than required body areas resulted in an increase of the organ doses by factors of up to 162 (testes), 162 (thyroid) and 8 (thyroid) for chest, abdomen and both chest and abdomen examinations, respectively. These exposures increased the average effective dose by factors of 2.0, 1.9 and 1.3 for the chest, abdomen and both chest and abdomen examinations, respectively. Differences in exposure parameters were found between the different neonatal intensive care units - tube voltage, current-time product and focal to skin distance differences up to 13, 44 and 22%, respectively. Reduction of at least 50% of neonate exposure is feasible and can be implemented using existing methodology without any additional costs. (authors)

  1. Environmental problems attributed due to increased road traffic intensity in Hyderabad city

    International Nuclear Information System (INIS)

    Memon, Z.; Ansari, A.K.

    2001-01-01

    Hyderabad is a historical city, so roads are not so wide to cater the present intensity of traffic, hence it is facing transportation problems. No any attempt of traffic management and control has been made in this regard to solve the acute problem of city. Some of the typical problems can be stated as poor driving, encroachments, unsystematic parking on roads, improper road markings and road sings, inadequate road geometry and inadequate control system at intersections etc. This study involves measurement of vehicles flow at five sites of Hyderabad city, and assessment of health hazards on human being due to noise congestion, improper road planning coupled with old city streets converted into roads which are now insufficient for present traffic density, resulting disturbance to pedestrians and dwellers who are living near by road for smooth walk. Motor vehicles, however, play a vital role in the field of public and goods transportation and this survey shows that there are about 726 vehicles operating per hour at the five sites in the city. (author)

  2. Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

    Science.gov (United States)

    Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich

    2005-02-01

    Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

  3. Comparison between the measurements of Radon Gas Concentrations and γ-ray intensities in Exploring the Black Sands at El-Burullus Beach

    International Nuclear Information System (INIS)

    Abdel-Razek, Y.A; Bakhit, A.F

    2009-01-01

    Ten well-located monitoring stations along El-Burullus beach were chosen to measure radon gas concentrations in the beach sands below surface, and γ-ray intensities at 10 cm above the surface. These stations were chosen to represent apparent concentrations of the black sands. Sand samples were collected from the different stations and analyzed to study the relation between the concentrations of the heavy minerals and the measured radon concentrations or the measured γ-ray intensities at these stations. It was found that radon gas concentrations measured at 6:00 Pm were about 2.82 times those measured at 1 :00 Pm due to diurnal variation of temperature. Measurements of radon gas concentrations inside the beach sands are found to be more reliable in qualitative exploration of black sands than the measurements of γ-ray intensities above the shore sands due to the random arrangement of the layers of these sands below surface

  4. Effects of Increasing Neuromuscular Electrical Stimulation Current Intensity on Cortical Sensorimotor Network Activation: A Time Domain fNIRS Study.

    Directory of Open Access Journals (Sweden)

    Makii Muthalib

    Full Text Available Neuroimaging studies have shown neuromuscular electrical stimulation (NMES-evoked movements activate regions of the cortical sensorimotor network, including the primary sensorimotor cortex (SMC, premotor cortex (PMC, supplementary motor area (SMA, and secondary somatosensory area (S2, as well as regions of the prefrontal cortex (PFC known to be involved in pain processing. The aim of this study, on nine healthy subjects, was to compare the cortical network activation profile and pain ratings during NMES of the right forearm wrist extensor muscles at increasing current intensities up to and slightly over the individual maximal tolerated intensity (MTI, and with reference to voluntary (VOL wrist extension movements. By exploiting the capability of the multi-channel time domain functional near-infrared spectroscopy technique to relate depth information to the photon time-of-flight, the cortical and superficial oxygenated (O2Hb and deoxygenated (HHb hemoglobin concentrations were estimated. The O2Hb and HHb maps obtained using the General Linear Model (NIRS-SPM analysis method, showed that the VOL and NMES-evoked movements significantly increased activation (i.e., increase in O2Hb and corresponding decrease in HHb in the cortical layer of the contralateral sensorimotor network (SMC, PMC/SMA, and S2. However, the level and area of contralateral sensorimotor network (including PFC activation was significantly greater for NMES than VOL. Furthermore, there was greater bilateral sensorimotor network activation with the high NMES current intensities which corresponded with increased pain ratings. In conclusion, our findings suggest that greater bilateral sensorimotor network activation profile with high NMES current intensities could be in part attributable to increased attentional/pain processing and to increased bilateral sensorimotor integration in these cortical regions.

  5. Effects of Increasing Neuromuscular Electrical Stimulation Current Intensity on Cortical Sensorimotor Network Activation: A Time Domain fNIRS Study.

    Science.gov (United States)

    Muthalib, Makii; Re, Rebecca; Zucchelli, Lucia; Perrey, Stephane; Contini, Davide; Caffini, Matteo; Spinelli, Lorenzo; Kerr, Graham; Quaresima, Valentina; Ferrari, Marco; Torricelli, Alessandro

    2015-01-01

    Neuroimaging studies have shown neuromuscular electrical stimulation (NMES)-evoked movements activate regions of the cortical sensorimotor network, including the primary sensorimotor cortex (SMC), premotor cortex (PMC), supplementary motor area (SMA), and secondary somatosensory area (S2), as well as regions of the prefrontal cortex (PFC) known to be involved in pain processing. The aim of this study, on nine healthy subjects, was to compare the cortical network activation profile and pain ratings during NMES of the right forearm wrist extensor muscles at increasing current intensities up to and slightly over the individual maximal tolerated intensity (MTI), and with reference to voluntary (VOL) wrist extension movements. By exploiting the capability of the multi-channel time domain functional near-infrared spectroscopy technique to relate depth information to the photon time-of-flight, the cortical and superficial oxygenated (O2Hb) and deoxygenated (HHb) hemoglobin concentrations were estimated. The O2Hb and HHb maps obtained using the General Linear Model (NIRS-SPM) analysis method, showed that the VOL and NMES-evoked movements significantly increased activation (i.e., increase in O2Hb and corresponding decrease in HHb) in the cortical layer of the contralateral sensorimotor network (SMC, PMC/SMA, and S2). However, the level and area of contralateral sensorimotor network (including PFC) activation was significantly greater for NMES than VOL. Furthermore, there was greater bilateral sensorimotor network activation with the high NMES current intensities which corresponded with increased pain ratings. In conclusion, our findings suggest that greater bilateral sensorimotor network activation profile with high NMES current intensities could be in part attributable to increased attentional/pain processing and to increased bilateral sensorimotor integration in these cortical regions.

  6. X-ray quality increasing system controlled by single-chip microcomputer in single phase fluoroscopy unit

    International Nuclear Information System (INIS)

    Wang Qiaolin; Gu Hongmei

    2004-01-01

    Objective: To decrease the amount of radiation that doctor and patient receives by increasing X-ray quality. Methods: Using Single-chip Microcomputer technology, test and modulate AC(Alternating Current) from high voltage generator by IGBT. X-ray tube generates X-rays only at high energy area. Thus the amount of radiation decreases. Results: The tube current decreases remarkably and the amount of radiation that doctor and patient receives decreases effectively. Conclusion: the system can effectively decrease the amount of radiation and is widely applicable to the upgrade of all kinds of single phase X-ray units. (authors)

  7. Recharge heterogeneity and high intensity rainfall events increase contamination risk for Mediterranean groundwater resources

    Science.gov (United States)

    Hartmann, Andreas; Jasechko, Scott; Gleeson, Tom; Wada, Yoshihide; Andreo, Bartolomé; Barberá, Juan Antonio; Brielmann, Heike; Charlier, Jean-Baptiste; Darling, George; Filippini, Maria; Garvelmann, Jakob; Goldscheider, Nico; Kralik, Martin; Kunstmann, Harald; Ladouche, Bernard; Lange, Jens; Mudarra, Matías; Francisco Martín, José; Rimmer, Alon; Sanchez, Damián; Stumpp, Christine; Wagener, Thorsten

    2017-04-01

    Karst develops through the dissolution of carbonate rock and results in pronounced spatiotemporal heterogeneity of hydrological processes. Karst groundwater in Europe is a major source of fresh water contributing up to half of the total drinking water supply in some countries like Austria or Slovenia. Previous work showed that karstic recharge processes enhance and alter the sensitivity of recharge to climate variability. The enhanced preferential flow from the surface to the aquifer may be followed by enhanced risk of groundwater contamination. In this study we assess the contamination risk of karst aquifers over Europe and the Mediterranean using simulated transit time distributions. Using a new type of semi-distributed model that considers the spatial heterogeneity of karst hydraulic properties, we were able to simulate karstic groundwater recharge including its heterogeneous spatiotemporal dynamics. The model is driven by gridded daily climate data from the Global Land Data Assimilation System (GLDAS). Transit time distributions are calculated using virtual tracer experiments. We evaluated our simulations by independent information on transit times derived from observed time series of water isotopes of >70 karst springs over Europe. The simulations indicate that, compared to humid, mountain and desert regions, the Mediterranean region shows a stronger risk of contamination in Europe because preferential flow processes are most pronounced given thin soil layers and the seasonal abundance of high intensity rainfall events in autumn and winter. Our modelling approach includes strong simplifications and its results cannot easily be generalized but it still highlights that the combined effects of variable climate and heterogeneous catchment properties constitute a strong risk on water quality.

  8. Optimization of mNeonGreen for Homo sapiens increases its fluorescent intensity in mammalian cells.

    Science.gov (United States)

    Tanida-Miyake, Emiko; Koike, Masato; Uchiyama, Yasuo; Tanida, Isei

    2018-01-01

    Green fluorescent protein (GFP) is tremendously useful for investigating many cellular and intracellular events. The monomeric GFP mNeonGreen is about 3- to 5-times brighter than GFP and monomeric enhanced GFP and shows high photostability. The maturation half-time of mNeonGreen is about 3-fold faster than that of monomeric enhanced GFP. However, the cDNA sequence encoding mNeonGreen contains some codons that are rarely used in Homo sapiens. For better expression of mNeonGreen in human cells, we synthesized a human-optimized cDNA encoding mNeonGreen and generated an expression plasmid for humanized mNeonGreen under the control of the cytomegalovirus promoter. The resultant plasmid was introduced into HEK293 cells. The fluorescent intensity of humanized mNeonGreen was about 1.4-fold higher than that of the original mNeonGreen. The humanized mNeonGreen with a mitochondria-targeting signal showed mitochondrial distribution of mNeonGreen. We further generated an expression vector of humanized mNeonGreen with 3xFLAG tags at its carboxyl terminus as these tags are useful for immunological analyses. The 3xFLAG-tagged mNeonGreen was recognized well with an anti-FLAG-M2 antibody. These plasmids for the expression of humanized mNeonGreen and mNeonGreen-3xFLAG are useful tools for biological studies in mammalian cells using mNeonGreen.

  9. Increasing the aperture of x-ray mosaic lenses by freeze drying

    International Nuclear Information System (INIS)

    Koch, F; Marschall, F; Meiser, J; Márkus, O; Faisal, A; Schröter, T; Meyer, P; Kunka, D; Last, A; Mohr, J

    2015-01-01

    Point focus x-ray mosaic lenses are limited in aperture by the aspect ratio that can be reached in the micro fabrication process. In lithography based micro fabrication processes, which are used to fabricate the lens pillar structures, the achievable aspect ratio is restricted by structure collapse due to capillary forces which occur during drying after development. Capillary forces can be avoided by freeze drying, hence avoiding the direct phase change from liquid to gas. Substituting conventional drying by freeze drying using cyclohexane at a temperature of  −10 °C, we could increase the achievable aspect ratio for the triangular pillar structures with edge length of 10 to 45 µm of the x-ray mosaic lenses by up to a factor of 2.2 with no further changes in process, material or structural geometry. A maximum aspect ratio of 30 was achieved for pillars with 10 µm edge length. The process can readily be employed to other structures or lithography techniques. (paper)

  10. Deriving the solar activity cycle modulation on cosmic ray intensity observed by Nagoya muon detector from October 1970 until December 2012

    Science.gov (United States)

    de Mendonça, Rafael R. S.; Braga, Carlos. R.; Echer, Ezequiel; Dal Lago, Alisson; Rockenbach, Marlos; Schuch, Nelson J.; Munakata, Kazuoki

    2017-10-01

    It is well known that the cosmic ray intensity observed at the Earth's surface presents an 11 and 22-yr variations associated with the solar activity cycle. However, the observation and analysis of this modulation through ground muon detectors datahave been difficult due to the temperature effect. Furthermore, instrumental changes or temporary problems may difficult the analysis of these variations. In this work, we analyze the cosmic ray intensity observed since October 1970 until December 2012 by the Nagoya muon detector. We show the results obtained after analyzing all discontinuities and gaps present in this data and removing changes not related to natural phenomena. We also show the results found using the mass weighted method for eliminate the influence of atmospheric temperature changes on muon intensity observed at ground. As a preliminary result of our analyses, we show the solar cycle modulation in the muon intensity observed for more than 40 years.

  11. Possibility of increasing intensity of mining by mechanization with use of shearer loaders

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Jaszczuk, M

    1981-10-01

    Discusses methods of increasing productivity of face systems in longwall mining. Feasibility of increasing coal output by variation of shearer loader haulage speed is analyzed. Effects of haulage speed variation on energy consumption or cutting tool wear are not considered. It is assumed that haulage speed does not depend on advance rate of the powered supports or the rate of face conveyor advance. Mathematical equations are derived for calculation of the optimum haulage speed variations. The method consists in use of variable haulage speed optimized for a given section of a longwall face without overloading the conveyor drive system. Situations with single drum shearer loaders and with bi-directional shearer loaders with cutting drums situated at both ends of the shearer are analyzed. Analyses show that by haulage speed variation shearer loader productivity is significantly increased. Performance tests under operational conditions show that in the case of a bi-directional shearer loader productivity increases by 31% and in the case of a shearer loader with a single drum by 11%. (4 refs.) (In Polish)

  12. Toward compact and ultra-intense laser-based soft x-ray lasers

    Science.gov (United States)

    Sebban, S.; Depresseux, A.; Oliva, E.; Gautier, J.; Tissandier, F.; Nejdl, J.; Kozlova, M.; Maynard, G.; Goddet, J. P.; Tafzi, A.; Lifschitz, A.; Kim, H. T.; Jacquemot, S.; Rousseau, P.; Zeitoun, P.; Rousse, A.

    2018-01-01

    We report here recent work on an optical field ionized (OFI), high-order harmonic-seeded EUV laser. The amplifying medium is a plasma of nickel-like krypton obtained by OFI when focusing a 1 J, 30 fs, circularly-polarized, infrared pulse into a krypton-filled gas cell or krypton gas jet. The lasing transition is the 3d94d (J = 0) → 3d94p (J = 1) transition of Ni-like krypton ions at 32.8 nm and is pumped by collisions with hot electrons. The gain dynamics was probed by seeding the amplifier with a high-order harmonic pulse at different delays. The gain duration monotonically decreased from 7 ps to an unprecedented shortness of 450 fs full width at half-maximum as the amplification peak rose from 150 to 1200 with an increase of the plasma density from 3 × 1018 to 1.2 × 1020 cm-3. The integrated energy of the EUV laser pulse was also measured, and found to be around 2 μJ. It is to be noted that in the ASE mode, longer amplifiers were achieved (up to 2 cm), yielding EUV outputs up to 14 μJ.

  13. Evaluation of the productivity decrease risk due to a future increase in tropical cyclone intensity in Japan.

    Science.gov (United States)

    Esteban, Miguel; Longarte-Galnares, Gorka

    2010-12-01

    A number of scientists have recently conducted research that shows that tropical cyclone intensity is likely to increase in the future. This would result in an increase in the damage along with a decrease in economic productivity due to precautionary cessation of the economic activity of the affected areas during the passage of the cyclone. The economic effect of this stop in economic activity is a phenomenon that has not received much attention in the past, and the cumulative effect that it can have on the Japanese economy over the next 75 years has never been evaluated. The starting point for the evaluation of the economic risks is the change in the patterns of tropical cyclone intensity suggested by Knutson and Tuleya. The results obtained show how a significant decrease in the overall productivity of the country could be expected, which could lower GDP by between 6% and 13% by 2085. © 2010 Society for Risk Analysis.

  14. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    International Nuclear Information System (INIS)

    Fiorella, D.; Helms, C.A.; Speer, K.P.

    2000-01-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  15. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Fiorella, D.; Helms, C.A. [Dept. of Radiology, Duke Univ., Durham, NC (United States); Speer, K.P. [Dept. of Orthopedic Surgery, Duke Univ., Durham, NC (United States)

    2000-12-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  16. Estimation of cerium and lanthanum content in core material of high intensity carbon arc electrodes by x-ray fluorescence method

    International Nuclear Information System (INIS)

    Nagpal, K.C.; Bhavalkar, R.H.

    1977-01-01

    The X-ray fluorescence method has been used to determine the weight percentages of cerium and lanthanum in the core material of high intensity carbon arc electrodes from the calibration curves plotted between the weight percentages of these elements and the peak-intensity ratios of CeLsub(α1), and LaLsub(α1) peaks to the neighbouring peak SnLsub(α1) due to an internal standard element. (author)

  17. Muon Intensity Increase by Wedge Absorbers for Low-E Muon Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, D. V. [Fermilab; Stratakis, D. [Fermilab; Bradley, J. [Fermilab

    2017-09-01

    Low energy muon experiments such as mu2e and g-2 have a limited energy spread acceptance. Following techniques developed in muon cooling studies and the MICE experiment, the number of muons within the desired energy spread can be increased by the matched use of wedge absorbers. More generally, the phase space of muon beams can be manipulated by absorbers in beam transport lines. Applications with simulation results are presented.

  18. Nordic Walking May Safely Increase the Intensity of Exercise Training in Healthy Subjects and in Patients with Chronic Heart Failure.

    Science.gov (United States)

    Lejczak, Andrzej; Josiak, Krystian; Węgrzynowska-Teodorczyk, Kinga; Rudzińska, Eliza; Jankowska, Ewa A; Banasiak, Waldemar; Piepoli, Massimo F; Woźniewski, Marek; Ponikowski, Piotr

    2016-01-01

    Physical activity in patients with chronic heart failure (HF) improves the exercise capacity and quality of life, and may also reduce mortality and hospitalizations. The greatest benefits are achieved through high-intensity aerobic exercises resulting in a stronger cardiorespiratory response. Nordic walking (NW), a walking technique using two poles and mimicking the movements performed while cross-country skiing, is associated with the involvement of more muscle groups than in the case of classic walking, and should therefore make it possible to increase exercise intensity, resulting in more effective training for patients with HF. The aim of the study was to assess the feasibility and safety of the NW technique, and to compare the effort intensity while walking with and without the NW technique in both healthy subjects and in patients with chronic HF. The study involved 12 healthy individuals (aged 30 ± 10 years, 5 men) and 12 men with stable chronic systolic HF (aged 63 ± 11 years, all categorized in New York Heart Association class II, median LVEF 30%, median peak VO(2) 18.25 mL/kg/min). All the participants completed two randomly assigned submaximal walking tests (one with NW poles and one without) conducted on a level treadmill for 6 min at a constant speed of 5 km/h. Walking with the NW technique was feasible, safe and well tolerated in all subjects. In both the control group and the chronic HF group, walking with the NW technique increased peak VO(2), RER, VE, PET CO(2), HR and SBP over walking without the poles; and the fatigue grade according to the abridged Borg scale was higher. Dyspnea did not increase significantly with the NW technique. The NW technique can increase the intensity of aerobic training in a safe and well-tolerated way in both healthy individuals and in patients with chronic HF.

  19. Increasing milk solids production across lactation through genetic selection and intensive pasture-based feed system.

    Science.gov (United States)

    Coleman, J; Pierce, K M; Berry, D P; Brennan, A; Horan, B

    2010-09-01

    The objective of the study was to quantify the effect of genetic improvement using the Irish total merit index, the Economic Breeding Index (EBI), on overall performance and lactation profiles for milk, milk solids, body weight (BW), and body condition score (BCS) within 2 pasture-based systems of milk production likely to be used in the future, following abolition of the European Union's milk quota system. Three genotypes of Holstein-Friesian dairy cattle were established from within the Moorepark dairy research herd: LowNA, indicative of animals with North American origin and average or lower genetic merit at the time of the study; HighNA, North American Holstein-Friesians of high genetic merit; and HighNZ, New Zealand Holstein-Friesians of high genetic merit. Animals from within each genotype were randomly allocated to 1 of 2 possible pasture-based feeding systems (FS): 1) The Moorepark pasture (MP) system (2.64 cows/ha and 344 kg of concentrate supplement per cow per lactation) and 2) a high output per hectare (HC) system (2.85 cows/ha and 1,056 kg of concentrate supplement per cow per lactation). Pasture was allocated to achieve similar postgrazing residual sward heights for both treatments. A total of 126, 128, and 140 spring-calving dairy cows were used during the years 2006, 2007, and 2008, respectively. Each group had an individual farmlet of 17 paddocks and all groups were managed similarly throughout the study. The effects of genotype, FS, and the interaction between genotype and FS on milk production, BW, and BCS across lactation were studied using mixed models with factorial arrangements of genotype and FS accounting for the repeated cow records across years. No significant genotype by FS interaction was observed for any of the variables measured. Results show that milk solids production of the national average dairy cow can be increased across lactation through increased EBI. High EBI genotypes (HighNA and HighNZ) produced more milk solids per cow and

  20. The response of a simulated mesoscale convective system to increased aerosol pollution: Part II: Derecho characteristics and intensity in response to increased pollution

    Science.gov (United States)

    Clavner, Michal; Grasso, Lewis D.; Cotton, William R.; van den Heever, Susan C.

    2018-01-01

    Mesoscale Convective Systems (MCS) are important contributors to rainfall as well as producers of severe weather such as hail, tornados, and straight-line wind events known as derechos. In this study, different aerosol concentrations and their effects on a derecho event are examined by simulating a case study, the 8 May 2009 "Super-Derecho", using the Regional Atmospheric Modeling System (RAMS), a cloud-resolving model with sophisticated aerosol and cloud microphysics. Three simulations were conducted that differed in the initial aerosol concentrations, spatial distribution and chemical composition as derived from output of GEOS-Chem, a 3D chemical transport model. In order to understand the impact of changes in aerosol concentrations on the derecho characteristics, the dynamical processes that produced the strong surface wind were determined by performing back-trajectory analysis during two periods of the simulated storm: the development and the onset of dissipation. A time dependent and non-monotonic trend was found between the intensity of the derecho and the increased aerosol concentrations that served as cloud condensation nuclei. During the formation period of the MCS, the non-monotonic trend was attributed to the microphysical impact of aerosol loading on the intensity of the cold pool; that is, the impact of aerosols on both the melting and evaporation rates of hydrometeors. The subsequent intensity changes within the cold pool modified the balance between the horizontal vorticity generated by the cold pool and that of the environment, thereby impacting the orientation of the convective updraft at the leading line. This, in turn, altered the primary flow that contributed to the formation of the derecho-strength surface winds. The simulation with no anthropogenic aerosols exhibited the strongest cold pool and the primary flow was associated with a descending rear inflow jet that produced the derecho winds over a larger region. The simulation with the highest

  1. X-rays diagnostics of the hot electron energy distribution in the intense laser interaction with metal targets

    Science.gov (United States)

    Kostenko, O. F.; Andreev, N. E.; Rosmej, O. N.

    2018-03-01

    A two-temperature hot electron energy distribution has been revealed by modeling of bremsstrahlung emission, measured by the radiation attenuation and half-shade methods, and Kα emission from a massive silver cylinder irradiated by a subpicosecond s-polarized laser pulse with a peak intensity of about 2 × 1019 W/cm2. To deduce parameters of the hot electron spectrum, we have developed semi-analytical models of generation and measurements of the x-rays. The models are based on analytical expressions and tabulated data on electron stopping power as well as cross-sections of generation and absorption of the x-rays. The Kα emission from thin silver foils deposited on low-Z substrates, both conducting and nonconducting, has been used to verify the developed models and obtained hot electron spectrum. The obtained temperatures of the colder and hotter electron components are in agreement with the values predicted by kinetic simulations of the cone-guided approach to fast ignition [Chrisman et al., Phys. Plasmas 15, 056309 (2008)]. The temperature of the low-energy component of the accelerated electron spectrum is well below the ponderomotive scaling and Beg's law. We have obtained relatively low conversion efficiency of laser energy into the energy of hot electrons propagating through the solid target of about 2%. It is demonstrated that the assumption about a single-temperature hot electron energy distribution with the slope temperature described by the ponderomotive scaling relationship, without detailed analysis of the hot electron spectrum, can lead to strong overestimation of the laser-to-electron energy-conversion efficiency, in particular, the conversion efficiency of laser energy into the high-temperature component of the hot electron distribution.

  2. Manipulating field margins to increase predation intensity in fields of winter wheat (Triticum eastivum)

    DEFF Research Database (Denmark)

    Mansion-Vaquie, Agathe; Ferrante, Marco; Cook, S M

    2017-01-01

    , intraguild predation, hyperparasitism) may complicate the assumption that a higher density of natural enemies would increase the level of biological control. We investigated the natural enemy guild composition and the predation rate along flower vs. grass margins at the edge of winter wheat (Triticum...... to the two margin types: specialists (mostly parasitic wasps) were attracted by the flower margins, while generalists (ground beetles, rove beetles and spiders) were more active in grass margins. The number of artificial caterpillars attacked was significantly greater in grass margins (mean = 48.9%, SD = 24...

  3. Crop growth and nitrogen turnover under increased temperatures and low autumn and winter light intensity

    DEFF Research Database (Denmark)

    Thomsen, Ingrid Kaag; Lægdsmand, Mette; Olesen, Jørgen E

    2010-01-01

    The rise in mean annual temperatures under the projected climate change will affect both soil organic matter turnover and cropping patterns in agriculture. Nitrogen (N) mineralization may be higher during autumn and winter and may increase the risk of nitrate leaching. Our study tested whether...... before the late sowing of wheat caused generally higher levels of inorganic N to accumulate in soil. Despite the higher mineralization under the raised temperatures, at T+8 the late-sown winter wheat was able to reduce soil inorganic N to a lower level than late-sown wheat at the two lower temperatures...

  4. Influence of low-intensity pulsed ultrasound on osteogenic tissue regeneration in a periodontal injury model: X-ray image alterations assessed by micro-computed tomography.

    Science.gov (United States)

    Wang, Yunji; Chai, Zhaowu; Zhang, Yuanyuan; Deng, Feng; Wang, Zhibiao; Song, Jinlin

    2014-08-01

    This study was conducted to evaluate, with micro-computed tomography, the influence of low-intensity pulsed ultrasound on wound-healing in periodontal tissues. Periodontal disease with Class II furcation involvement was surgically produced at the bilateral mandibular premolars in 8 adult male beagle dogs. Twenty-four teeth were randomly assigned among 4 groups (G): G1, periodontal flap surgery; G2, periodontal flap surgery+low-intensity pulsed ultrasound (LIPUS); G3, guided tissue regeneration (GTR) surgery; G4, GTR surgery plus LIPUS. The affected area in the experimental group was exposed to LIPUS. At 6 and 8weeks, the X-ray images of regenerated teeth were referred to micro-CT scanning for 3-D measurement. Bone volume (BV), bone surface (BS), and number of trabeculae (Tb) in G2 and G4 were higher than in G1 and G3 (pperiodontal flap surgery group. LIPUS irradiation increased the number, volume, and area of new alveolar bone trabeculae. LIPUS has the potential to promote the repair of periodontal tissue, and may work effectively if combined with GTR. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Usage of γ-ray treatment for productivity increasing of maize

    International Nuclear Information System (INIS)

    Ilieva, V.; Dimov, K.

    2003-01-01

    The aim of this study is to determine the influence of γ irradiation on phosphorus nutrition and maize productivity increasing. The vegetation experiment with irradiated and non-irradiated maize seeds in controlled conditions (moisture and temperature) for determination of phosphorus and phosphorus-gypsum absorption was carried out. The influence of γ irradiation on maize growth, export of mineral elements in maize, phosphorus fertilizing and dry biomass of maize plants are presented. The effect of the moisture of γ irradiated maize seeds (sort 'Knezha' - 3L - 621) on dry substance and yield of green mass is also discussed. Based on the presented experimental data the following conclusion have been made: the maize seeds (sort 'Knezha, hybrid H-708) simulation is useful; in all variants of phosphorus-gypsum absorption the increasing of plant mass yield (absolutely dry) is observed; the absorbed phosphates reserve is enhanced twice; the efficiency of 32 P use in stimulated seeds is higher than in non-stimulated seeds; the phosphorus content in maize (sort 'Knezha' - 2L - 611) is increasing mainly in leaves after X-ray irradiation (750 - 1500 R); γ irradiation (7.5 Gy) stimulate the root system (18%) and side roots development and drying up overcome

  6. Carbon-Increasing Catalytic Strategies for Upgrading Biomass into Energy-Intensive Fuels and Chemicals

    DEFF Research Database (Denmark)

    Li, Hu; Riisager, Anders; Saravanamurugan, Shunmugavel

    2017-01-01

    Lignocellulosic biomass is the most abundant organic carbon source and has received a great deal of interest as renewable and sustainable feedstock for the production of potential biofuels and value-added chemicals with a wide range of designed catalytic systems. However, those natural polymeric...... materials are composed of short-chain monomers (typically C6 and C5 sugars) and complex lignin molecules containing plenty of oxygen, resulting in products during the downstream processing having low-grade fuel properties or limited applications in organic syntheses. Accordingly, approaches to increase...... corresponding key intermediates or final products are also reviewed. The effects of catalyst structure/type and reaction parameters on the catalytic performance along with relevant reaction mechanisms are in detail discussed. Apart from this, the formation of other useful compounds containing C-X bonds (X = O...

  7. The neutron beam intensity increase by in-core fuel management enhancement in multipurpose research reactors

    International Nuclear Information System (INIS)

    Martinc, R.; Vukadin, Z.; Konstantinovic, J.

    1986-01-01

    The exploitation characteristics of an existing multipurpose research reactor can be increased not only by great reconstruction, but also, to the considerable extent, by the in-core fuel management sophistication. The optimisation of the in-core fuel management procedure in such reactors is governed (among others) by the identified reactor utilisation goals, i.e. by weighting factors dedicated to different utilisation goals, which are often (regarding the in-core fuel management procedure) highly controversial. In this work the best solution for in-core fuel management is sought, with the highest weighting factor dedicated to the neutron beam usage, rather than sample irradiation in the reactor core. The term in-core fuel management includes: the core configuration, the locations of the fresh fuel inflow zone and spent fuel excite zone, and the fuel transfers between these two zones (author)

  8. Skin temperature increase mediated by wearable, long duration, low-intensity therapeutic ultrasound

    Science.gov (United States)

    Langer, Matthew D.; Huang, Wenyi; Ghanem, Angi; Guo, Yuan; Lewis, George K.

    2017-03-01

    One of the safety concerns with the delivery of therapeutic ultrasound is overheating of the transducer-skin interface due to poor or improper coupling. The objective of this research was to define a model that could be used to calculate the heating in the skin as a result of a novel, wearable long-duration ultrasound device. This model was used to determine that the maximum heating in the skin remained below the minimum threshold necessary to cause thermal injury over multiple hours of use. In addition to this model data, a human clinical study used wire thermocouples on the skin surface to measure heating characteristics during treatment with the sustained ultrasound system. Parametric analysis of the model determined that the maximum temperature increase is at the surface of the skin ranged from 40-41.8° C when perfusion was taken into account. The clinical data agreed well with the model predictions. The average steady state temperature observed across all 44 subjects was 40°C. The maximum temperature observed was less than 44° C, which is clinically safe for over 5 hours of human skin contact. The resultant clinical temperature data paired well with the model data suggesting the model can be used for future transducer and ultrasound system design simulation. As a result, the device was validated for thermal safety for typical users and use conditions.

  9. MRI to X-ray mammography intensity-based registration with simultaneous optimisation of pose and biomechanical transformation parameters.

    Science.gov (United States)

    Mertzanidou, Thomy; Hipwell, John; Johnsen, Stian; Han, Lianghao; Eiben, Bjoern; Taylor, Zeike; Ourselin, Sebastien; Huisman, Henkjan; Mann, Ritse; Bick, Ulrich; Karssemeijer, Nico; Hawkes, David

    2014-05-01

    Determining corresponding regions between an MRI and an X-ray mammogram is a clinically useful task that is challenging for radiologists due to the large deformation that the breast undergoes between the two image acquisitions. In this work we propose an intensity-based image registration framework, where the biomechanical transformation model parameters and the rigid-body transformation parameters are optimised simultaneously. Patient-specific biomechanical modelling of the breast derived from diagnostic, prone MRI has been previously used for this task. However, the high computational time associated with breast compression simulation using commercial packages, did not allow the optimisation of both pose and FEM parameters in the same framework. We use a fast explicit Finite Element (FE) solver that runs on a graphics card, enabling the FEM-based transformation model to be fully integrated into the optimisation scheme. The transformation model has seven degrees of freedom, which include parameters for both the initial rigid-body pose of the breast prior to mammographic compression, and those of the biomechanical model. The framework was tested on ten clinical cases and the results were compared against an affine transformation model, previously proposed for the same task. The mean registration error was 11.6±3.8mm for the CC and 11±5.4mm for the MLO view registrations, indicating that this could be a useful clinical tool. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  10. A more general expression for the average X-ray diffraction intensity of crystals with an incommensurate one-dimensional modulation

    International Nuclear Information System (INIS)

    Lam, E.J.W.; Beurskens, P.T.; Smaalen, S. van

    1994-01-01

    Statistical methods are used to derive an expression for the average X-ray diffraction intensity, as a function of (sinθ)/λ, of crystals with an incommensurate one-dimensional modulation. Displacive and density modulations are considered, as well as a combination of these two. The atomic modulation functions are given by truncated Fourier series that may contain higher-order harmonics. The resulting expression for the average X-ray diffraction intensity is valid for main reflections and low-order satellite reflections. The modulation of individual atoms is taken into account by the introduction of overall modulation amplitudes. The accuracy of this expression for the average X-ray diffraction intensity is illustrated by comparison with model structures. A definition is presented for normalized structure factors of crystals with an incommensurate one-dimensional modulation that can be used in direct-methods procedures for solving the phase problem in X-ray crystallography. A numerical fitting procedure is described that can extract a scale factor, an overall temperature parameter and overall modulation amplitudes from experimental reflection intensities. (orig.)

  11. A paradoxical signal intensity increase in fatty livers using opposed-phase gradient echo imaging with fat-suppression pulses

    International Nuclear Information System (INIS)

    Mulkern, Robert V.; Voss, Stephan; Loeb Salsberg, Sandra; Krauel, Marta Ramon; Ludwig, David S.

    2008-01-01

    With the increase in obese and overweight children, nonalcoholic fatty liver disease has become more prevalent in the pediatric population. Appreciating subtleties of magnetic resonance (MR) signal intensity behavior from fatty livers under different imaging conditions thus becomes important to pediatric radiologists. We report an initially confusing signal behavior - increased signal from fatty livers when fat-suppression pulses are applied in an opposed-phase gradient echo imaging sequence - and seek to explain the physical mechanisms for this paradoxical signal intensity behavior. Abdominal MR imaging at 3 T with a 3-D volumetric interpolated breath-hold (VIBE) sequence in the opposed-phase condition (TR/TE 3.3/1.3 ms) was performed in five obese boys (14±2 years of age, body mass index >95th percentile for age and sex) with spectroscopically confirmed fatty livers. Two VIBE acquisitions were performed, one with and one without the use of chemical shift selective (CHESS) pulse fat suppression. The ratios of fat-suppressed over non-fat-suppressed signal intensities were assessed in regions-of-interest (ROIs) in five tissues: subcutaneous fat, liver, vertebral marrow, muscle and spleen. The boys had spectroscopically estimated hepatic fat levels between 17% and 48%. CHESS pulse fat suppression decreased subcutaneous fat signals dramatically, by more than 85% within regions of optimal fat suppression. Fatty liver signals, in contrast, were elevated by an average of 87% with CHESS pulse fat suppression. Vertebral marrow signal was also significantly elevated with CHESS pulse fat suppression, while spleen and muscle signals demonstrated only small signal increases on the order of 10%. We demonstrated that CHESS pulse fat suppression actually increases the signal intensity from fatty livers in opposed-phase gradient echo imaging conditions. The increase can be attributed to suppression of one partner of the opposed-phase pair that normally contributes to the

  12. A paradoxical signal intensity increase in fatty livers using opposed-phase gradient echo imaging with fat-suppression pulses

    Energy Technology Data Exchange (ETDEWEB)

    Mulkern, Robert V.; Voss, Stephan [Harvard Medical School, Department of Radiology, Children' s Hospital Boston, Boston, MA (United States); Loeb Salsberg, Sandra; Krauel, Marta Ramon; Ludwig, David S. [Harvard Medical School, Department of Medicine, Children' s Hospital Boston, Boston, MA (United States)

    2008-10-15

    With the increase in obese and overweight children, nonalcoholic fatty liver disease has become more prevalent in the pediatric population. Appreciating subtleties of magnetic resonance (MR) signal intensity behavior from fatty livers under different imaging conditions thus becomes important to pediatric radiologists. We report an initially confusing signal behavior - increased signal from fatty livers when fat-suppression pulses are applied in an opposed-phase gradient echo imaging sequence - and seek to explain the physical mechanisms for this paradoxical signal intensity behavior. Abdominal MR imaging at 3 T with a 3-D volumetric interpolated breath-hold (VIBE) sequence in the opposed-phase condition (TR/TE 3.3/1.3 ms) was performed in five obese boys (14{+-}2 years of age, body mass index >95th percentile for age and sex) with spectroscopically confirmed fatty livers. Two VIBE acquisitions were performed, one with and one without the use of chemical shift selective (CHESS) pulse fat suppression. The ratios of fat-suppressed over non-fat-suppressed signal intensities were assessed in regions-of-interest (ROIs) in five tissues: subcutaneous fat, liver, vertebral marrow, muscle and spleen. The boys had spectroscopically estimated hepatic fat levels between 17% and 48%. CHESS pulse fat suppression decreased subcutaneous fat signals dramatically, by more than 85% within regions of optimal fat suppression. Fatty liver signals, in contrast, were elevated by an average of 87% with CHESS pulse fat suppression. Vertebral marrow signal was also significantly elevated with CHESS pulse fat suppression, while spleen and muscle signals demonstrated only small signal increases on the order of 10%. We demonstrated that CHESS pulse fat suppression actually increases the signal intensity from fatty livers in opposed-phase gradient echo imaging conditions. The increase can be attributed to suppression of one partner of the opposed-phase pair that normally contributes to the

  13. Ultrashort x-ray pulse generation by nonlinear Thomson scattering of a relativistic electron with an intense circularly polarized laser pulse

    Directory of Open Access Journals (Sweden)

    F. Liu

    2012-07-01

    Full Text Available The nonlinear Thomson scattering of a relativistic electron with an intense laser pulse is calculated numerically. The results show that an ultrashort x-ray pulse can be generated by an electron with an initial energy of 5 MeV propagating across a circularly polarized laser pulse with a duration of 8 femtosecond and an intensity of about 1.1×10^{21}  W/cm^{2}, when the detection direction is perpendicular to the propagation directions of both the electron and the laser beam. The optimal values of the carrier-envelop phase and the intensity of the laser pulse for the generation of a single ultrashort x-ray pulse are obtained and verified by our calculations of the radiation characteristics.

  14. Determination of the X-ray mass absorption coefficient by measurement of the intensity of AgKα Compton scattered radiation

    International Nuclear Information System (INIS)

    Franzini, M.; Leoni, L.; Saitta, M.

    1976-01-01

    By utilizing a reflection geometry, an accurate mass absorption coefficient of a sample can be determined by measuring the Ag Kα Compton intensity. Intensities of Ag Kα Compton scattered radiation have been collected by using either the usual reflection geometry of a Philips PW 1450 automatic x-ray spectrometer or a more refined reflection geometry, achieved on a Philips PW 1540/10A manual x-ray spectrometer. The experimental results have shown that the relationship between the Ag Kα Compton intensity and the mass absorption is a logarithmic function. The experimental results are not in agreement with those reported in literature, but a theoretical explanation to account for this fact has not been achieved as yet. (author)

  15. Acute high-intensity interval running increases markers of gastrointestinal damage and permeability but not gastrointestinal symptoms.

    Science.gov (United States)

    Pugh, Jamie N; Impey, Samuel G; Doran, Dominic A; Fleming, Simon C; Morton, James P; Close, Graeme L

    2017-09-01

    The purpose of this study was to investigate the effects of high-intensity interval running on markers of gastrointestinal (GI) damage and permeability alongside subjective symptoms of GI discomfort. Eleven male runners completed an acute bout of high-intensity interval training (HIIT) (eighteen 400-m runs at 120% maximal oxygen uptake) where markers of GI permeability, intestinal damage, and GI discomfort symptoms were assessed and compared with resting conditions. Compared with rest, HIIT significantly increased serum lactulose/rhamnose ratio (0.051 ± 0.016 vs. 0.031 ± 0.021, p = 0.0047; 95% confidence interval (CI) = 0.006 to 0.036) and sucrose concentrations (0.388 ± 0.217 vs. 0.137 ± 0.148 mg·L -1 ; p HIIT and resting conditions. Plasma intestinal-fatty acid binding protein (I-FABP) was significantly increased (p HIIT whereas no changes were observed during rest. Mild symptoms of GI discomfort were reported immediately and at 24 h post-HIIT, although these symptoms did not correlate to GI permeability or I-FABP. In conclusion, acute HIIT increased GI permeability and intestinal I-FABP release, although these do not correlate with symptoms of GI discomfort. Furthermore, by using serum sampling, we provide data showing that it is possible to detect changes in intestinal permeability that is not observed using urinary sampling over a shorter time-period.

  16. Intensive removal of signal crayfish (Pacifastacus leniusculus) from rivers increases numbers and taxon richness of macroinvertebrate species.

    Science.gov (United States)

    Moorhouse, Tom P; Poole, Alison E; Evans, Laura C; Bradley, David C; Macdonald, David W

    2014-02-01

    Invasive species are a major cause of species extinction in freshwater ecosystems, and crayfish species are particularly pervasive. The invasive American signal crayfish Pacifastacus leniusculus has impacts over a range of trophic levels, but particularly on benthic aquatic macroinvertebrates. Our study examined the effect on the macroinvertebrate community of removal trapping of signal crayfish from UK rivers. Crayfish were intensively trapped and removed from two tributaries of the River Thames to test the hypothesis that lowering signal crayfish densities would result in increases in macroinvertebrate numbers and taxon richness. We removed 6181 crayfish over four sessions, resulting in crayfish densities that decreased toward the center of the removal sections. Conversely in control sections (where crayfish were trapped and returned), crayfish density increased toward the center of the section. Macroinvertebrate numbers and taxon richness were inversely correlated with crayfish densities. Multivariate analysis of the abundance of each taxon yielded similar results and indicated that crayfish removals had positive impacts on macroinvertebrate numbers and taxon richness but did not alter the composition of the wider macroinvertebrate community. Synthesis and applications: Our results demonstrate that non-eradication-oriented crayfish removal programmes may lead to increases in the total number of macroinvertebrates living in the benthos. This represents the first evidence that removing signal crayfish from riparian systems, at intensities feasible during control attempts or commercial crayfishing, may be beneficial for a range of sympatric aquatic macroinvertebrates.

  17. Intensive training and reduced volume increases muscle FXYD1 expression and phosphorylation at rest and during exercise in athletes

    DEFF Research Database (Denmark)

    Thomassen, Martin; Gunnarsson, Thomas Gunnar Petursson; Christensen, Peter Møller

    2016-01-01

    and phosphorylation were determined by western blotting. Expression of FXYD1 (30%), actin (40%), mTOR (12%), PLN (16%) and CaMKII γ/δ (25%) was higher (P... and during exercise, mainly achieved by an increased FXYD1 ser68 phosphorylation, compared to before the intervention. CaMKII thr287 and eEF2 thr56 phosphorylation at rest and during exercise, overall PKCα/β thr638/641 and mTOR ser2448 phosphorylation during repeated intense exercise as well as resting PLN...

  18. Intensive skills week for military medical students increases technical proficiency, confidence, and skills to minimize negative stress.

    Science.gov (United States)

    Mueller, Genevieve; Hunt, Bonnie; Wall, Van; Rush, Robert; Molof, Alan; Schoeff, Jonathan; Wedmore, Ian; Schmid, James; Laporta, Anthony

    2012-01-01

    The effects of stress induced cortisol on learning and memory is well documented in the literature.1-3 Memory and learning are enhanced at low levels while high levels are detrimental. Repetitive training in stressful situations enables management of the stress response4 as demonstrated by the high intensity training military members undergo to prepare for tactical situations. Appropriate management of one?s stress response is critical in the medical field, as the negative effects of stress can potentially hinder life-saving procedures and treatments. This also applies to physicians-in-training as they learn and practice triage, emergency medicine, and surgical skills prior to graduation. Rocky Vista University?s Military Medicine Honor?s Track (MMHT) held a week long high-intensity emergency medicine and surgical Intensive Skills Week (ISW), facilitated by military and university physicians, to advance students? skills and maximize training using the Human Worn Partial Surgical Task Simulator (Cut Suit). The short-term goal of the ISW was to overcome negative stress responses to increase confidence, technical and non-technical knowledge, and skill in surgery and emergency medicine in an effort to improve performance as third-year medical students. The long-term goal was to enhance performance and proficiency in residency and future medical practice. The metrics for the short-term goals were the focus of this pilot study. Results show an increase in confidence and decrease in perceived stress as well as statistically significant improvements in technical and non-technical skills and surgical instrumentation knowledge throughout the week. There is a correlative benefit to physician and non-physician military personnel, especially Special Operations Forces (SOF) medical personnel, from developing and implementing similar training programs when live tissue or cadaver models are unavailable or unfeasible. 2012.

  19. Solar induced long- and short-term variations of the cosmic ray intensity in the past, and predictions and opportunities for the future

    Science.gov (United States)

    McCracken, K. G.; McDonald, F. B.; Beer, J.

    2009-12-01

    The cosmogenic radionuclide data from the past 10,000 years, and the instrumental cosmic ray data since 1936 provide detailed information on the possible consequences of the present long and deep solar minimum. Furthermore, the cosmic ray transport equation has been used to estimate the strength of the interplanetary magnetic field (IMF) throughout the past 10,000 years. This paper presents a series of figures that document the behavior of both the cosmic radiation and the IMF at Earth in the past. In particular, the 11-year cycles in both quantities for the past 600 years are displayed; and estimates given of the cosmic ray spectrum at Earth for situations that history tells us may occur in the near future. Over the longer term, a minimum of the Hallstatt cycle (2200 yr periodicity) of solar activity occurred ~500 years ago and the Sun is now on a steadily rising plane of activity. The historic record shows that the cosmic ray intensity has decreased extremely rapidly after earlier prolonged deep minima and this suggests rapid and large changes in the heliospheric conditions that we may see replicated. The paper will also display data from the deep, isolated solar minimum of 1956 that exhibited unusual low energy cosmic ray fluxes, and a highly anomalous cosmic ray gradient in the inner heliosphere. Paleo-cosmic ray evidence will also be displayed of an episode of intense solar energetic particle (SEP) events in the interval of reduced solar activity, 1892-1900, that may possibly be repeated. If the present long, deep solar minimum is a precursor to a “Grand Minimum” such as the Dalton minimum, it will provide a much improved insight into the spectrum of the cosmic radiation in interstellar space, and to the cosmic ray modulation process in the heliosphere. With this in mind, the paper suggests key measurements, and speculates on experimental conditions that may be markedly different from those encountered in the instrumental era.

  20. Consistency of neutron and proton capture intensity standards new relative intensities for 56Co, 66Ga decay and 35Cl(n,γ) reaction gamma rays

    International Nuclear Information System (INIS)

    Molnar, G.L.; Revay, Z.; Belgya, T.

    2000-01-01

    The equivalence of efficiency determination procedures based on neutron and proton capture lines has been verified and the deviation of high-energy efficiency from linearity confirmed. The new, accurate relative intensities for 56 Co and 66 Ga extend the range of secondary radioactive standards up to 4.8 MeV. Extreme care has to be taken with any high-energy intensity value obtained in the past with the help of 56 Co and 66 Ga calibration sources, and corrections have to be made using the present data of high accuracy. Relative intensities have also been improved for the 35 Cl(n,γ) reaction, a useful secondary standard in a wide energy range, between 0.3-8.5 MeV. The new data are supported by other most recent measurements of a slightly lower precision

  1. Intensification and deepening of the Arabian Sea oxygen minimum zone in response to increase in Indian monsoon wind intensity

    Science.gov (United States)

    Lachkar, Zouhair; Lévy, Marina; Smith, Shafer

    2018-01-01

    The decline in oxygen supply to the ocean associated with global warming is expected to expand oxygen minimum zones (OMZs). This global trend can be attenuated or amplified by regional processes. In the Arabian Sea, the world's thickest OMZ is highly vulnerable to changes in the Indian monsoon wind. Evidence from paleo-records and future climate projections indicates strong variations of the Indian monsoon wind intensity over climatic timescales. Yet, the response of the OMZ to these wind changes remains poorly understood and its amplitude and timescale unexplored. Here, we investigate the impacts of perturbations in Indian monsoon wind intensity (from -50 to +50 %) on the size and intensity of the Arabian Sea OMZ, and examine the biogeochemical and ecological implications of these changes. To this end, we conducted a series of eddy-resolving simulations of the Arabian Sea using the Regional Ocean Modeling System (ROMS) coupled to a nitrogen-based nutrient-phytoplankton-zooplankton-detritus (NPZD) ecosystem model that includes a representation of the O2 cycle. We show that the Arabian Sea productivity increases and its OMZ expands and deepens in response to monsoon wind intensification. These responses are dominated by the perturbation of the summer monsoon wind, whereas the changes in the winter monsoon wind play a secondary role. While the productivity responds quickly and nearly linearly to wind increase (i.e., on a timescale of years), the OMZ response is much slower (i.e., a timescale of decades). Our analysis reveals that the OMZ expansion at depth is driven by increased oxygen biological consumption, whereas its surface weakening is induced by increased ventilation. The enhanced ventilation favors episodic intrusions of oxic waters in the lower epipelagic zone (100-200 m) of the western and central Arabian Sea, leading to intermittent expansions of marine habitats and a more frequent alternation of hypoxic and oxic conditions there. The increased

  2. Intensification and deepening of the Arabian Sea oxygen minimum zone in response to increase in Indian monsoon wind intensity

    Directory of Open Access Journals (Sweden)

    Z. Lachkar

    2018-01-01

    Full Text Available The decline in oxygen supply to the ocean associated with global warming is expected to expand oxygen minimum zones (OMZs. This global trend can be attenuated or amplified by regional processes. In the Arabian Sea, the world's thickest OMZ is highly vulnerable to changes in the Indian monsoon wind. Evidence from paleo-records and future climate projections indicates strong variations of the Indian monsoon wind intensity over climatic timescales. Yet, the response of the OMZ to these wind changes remains poorly understood and its amplitude and timescale unexplored. Here, we investigate the impacts of perturbations in Indian monsoon wind intensity (from −50 to +50 % on the size and intensity of the Arabian Sea OMZ, and examine the biogeochemical and ecological implications of these changes. To this end, we conducted a series of eddy-resolving simulations of the Arabian Sea using the Regional Ocean Modeling System (ROMS coupled to a nitrogen-based nutrient–phytoplankton–zooplankton–detritus (NPZD ecosystem model that includes a representation of the O2 cycle. We show that the Arabian Sea productivity increases and its OMZ expands and deepens in response to monsoon wind intensification. These responses are dominated by the perturbation of the summer monsoon wind, whereas the changes in the winter monsoon wind play a secondary role. While the productivity responds quickly and nearly linearly to wind increase (i.e., on a timescale of years, the OMZ response is much slower (i.e., a timescale of decades. Our analysis reveals that the OMZ expansion at depth is driven by increased oxygen biological consumption, whereas its surface weakening is induced by increased ventilation. The enhanced ventilation favors episodic intrusions of oxic waters in the lower epipelagic zone (100–200 m of the western and central Arabian Sea, leading to intermittent expansions of marine habitats and a more frequent alternation of hypoxic and oxic conditions there

  3. Long-term intensive management increased carbon occluded in phytolith (PhytOC) in bamboo forest soils

    Science.gov (United States)

    Huang, Zhang-Ting; Li, Yong-Fu; Jiang, Pei-Kun; Chang, Scott X.; Song, Zhao-Liang; Liu, Juan; Zhou, Guo-Mo

    2014-01-01

    Carbon (C) occluded in phytolith (PhytOC) is highly stable at millennium scale and its accumulation in soils can help increase long-term C sequestration. Here, we report that soil PhytOC storage significantly increased with increasing duration under intensive management (mulching and fertilization) in Lei bamboo (Phyllostachys praecox) plantations. The PhytOC storage in 0-40 cm soil layer in bamboo plantations increased by 217 Mg C ha-1, 20 years after being converted from paddy fields. The PhytOC accumulated at 79 kg C ha-1 yr-1, a rate far exceeding the global mean long-term soil C accumulation rate of 24 kg C ha-1 yr-1 reported in the literature. Approximately 86% of the increased PhytOC came from the large amount of mulch applied. Our data clearly demonstrate the decadal scale management effect on PhytOC accumulation, suggesting that heavy mulching is a potential method for increasing long-term organic C storage in soils for mitigating global climate change.

  4. Global warming hiatus contributed to the increased occurrence of intense tropical cyclones in the coastal regions along East Asia.

    Science.gov (United States)

    Zhao, Jiuwei; Zhan, Ruifen; Wang, Yuqing

    2018-04-16

    The recent global warming hiatus (GWH) was characterized by a La Niña-like cooling in the tropical Eastern Pacific accompanied with the Indian Ocean and the tropical Atlantic Ocean warming. Here we show that the recent GWH contributed significantly to the increased occurrence of intense tropical cyclones in the coastal regions along East Asia since 1998. The GWH associated sea surface temperature anomalies triggered a pair of anomalous cyclonic and anticyclonic circulations and equatorial easterly anomalies over the Northwest Pacific, which favored TC genesis and intensification over the western Northwest Pacific but suppressed TC genesis and intensification over the southeastern Northwest Pacific due to increased vertical wind shear and anticyclonic circulation anomalies. Results from atmospheric general circulation model experiments demonstrate that the Pacific La Niña-like cooling dominated the Indian Ocean and the tropical Atlantic Ocean warming in contributing to the observed GWH-related anomalous atmospheric circulation over the Northwest Pacific.

  5. Modifying effects of low-intensity extremely high-frequency electromagnetic radiation on content and composition of fatty acids in thymus of mice exposed to X-rays.

    Science.gov (United States)

    Gapeyev, Andrew B; Aripovsky, Alexander V; Kulagina, Tatiana P

    2015-03-01

    The effects of extremely high-frequency electromagnetic radiation (EHF EMR) on thymus weight and its fatty acids (FA) content and FA composition in X-irradiated mice were studied to test the involvement of FA in possible protective effects of EHF EMR against ionizing radiation. Mice were exposed to low-intensity pulse-modulated EHF EMR (42.2 GHz, 0.1 mW/cm(2), 20 min exposure, 1 Hz modulation) and/or X-rays at a dose of 4 Gy with different sequences of the treatments. In 4-5 hours, 10, 30, and 40 days after the last exposure, the thymuses were weighed; total FA content and FA composition of the thymuses were determined on days 1, 10, and 30 using a gas chromatography. It was shown that after X-irradiation of mice the total FA content per mg of thymic tissue was significantly increased in 4-5 h and decreased in 10 and 30 days after the treatment. On days 30 and 40 after X-irradiation, the thymus weight remained significantly reduced. The first and tenth days after X-rays injury independently of the presence and sequence of EHF EMR exposure were characterized by an increased content of polyunsaturated FA (PUFA) and a decreased content of monounsaturated FA (MUFA) with unchanged content of saturated FA (SFA). Exposure of mice to EHF EMR before or after X-irradiation prevented changes in the total FA content in thymic tissue, returned the summary content of PUFA and MUFA to the control level and decreased the summary content of SFA on the 30th day after the treatments, and promoted the restoration of the thymus weight of X-irradiated mice to the 40th day of the observations. Changes in the content and composition of PUFA in the early period after treatments as well as at the restoration of the thymus weight under the combined action of EHF EMR and X-rays indicate to an active participation of FA in the acceleration of post-radiation recovery of the thymus by EHF EMR exposure.

  6. Comparison of γ-ray intensity distribution around Hira fault with spatial pattern of major and/or sub fault system

    International Nuclear Information System (INIS)

    Nakanishi, Tatsuya; Mino, Kazuo; Ogasawara, Hiroshi; Katsura, Ikuo

    1999-01-01

    Major active faults generally consist of systems of a number of fractures with various dimensions, and contain a lot of ground water. Rn gas, moving with underground water, tends to accumulate along faults and emit γ-ray while it decays down to Pb through Bi. Therefore, it has been shown by a number of works that γ-ray intensity is generally high near the core of the major active fault and the γ-ray survey is one of the effective methods to look for the core of the major active fault. However, around the area near the tips of faults, a number of complicated sub-fault systems and the corresponding complicated geological structures are often seen and it has not been investigated well about what can be the relationship between the intensity distribution of γ-ray and the fault systems. In order to investigate the relationship in an area near the tips of major faults well, therefore, we carried out the γ-ray survey at about 1,100 sites in an area of about 2 km x 2 km that has the tips of the two major right lateral faults with significant thrusting components. We also investigated the lineaments by using the topographic map published in 1895 when artificial construction was seldom seen in the area and we can easily see the natural topography. In addition, we carried out the γ-ray survey in an area far from the fault tip to compare with the results in the area with the fault tips. Then: (1) we reconfirmed that in the case of the middle of the major active fault, γ-ray intensity is high in the limited area just adjacent to the core of the fault. (2) However, we found that in the case of the tip of the major active fault, high γ-ray intensity is seen in much wider area with clear lineaments that is inferred to be developed associated with the movement of the major faults. (author)

  7. Apoptotic cell death during Drosophila oogenesis is differentially increased by electromagnetic radiation depending on modulation, intensity and duration of exposure.

    Science.gov (United States)

    Sagioglou, Niki E; Manta, Areti K; Giannarakis, Ioannis K; Skouroliakou, Aikaterini S; Margaritis, Lukas H

    2016-01-01

    Present generations are being repeatedly exposed to different types and doses of non-ionizing radiation (NIR) from wireless technologies (FM radio, TETRA and TV stations, GSM and UMTS phones/base stations, Wi-Fi networks, DECT phones). Although there is controversy on the published data regarding the non-thermal effects of NIR, studies have convincingly demonstrated bioeffects. Their results indicate that modulation, intensity, exposure duration and model system are important factors determining the biological response to irradiation. Attempting to address the dependence of NIR bioeffectiveness on these factors, apoptosis in the model biological system Drosophila melanogaster was studied under different exposure protocols. A signal generator was used operating alternatively under Continuous Wave (CW) or Frequency Modulation (FM) emission modes, at three power output values (10 dB, 0, -10 dB), under four carrier frequencies (100, 395, 682, 900 MHz). Newly emerged flies were exposed either acutely (6 min or 60 min on the 6th day), or repeatedly (6 min or 60 min daily for the first 6 days of their life). All exposure protocols resulted in an increase of apoptotic cell death (ACD) observed in egg chambers, even at very low electric field strengths. FM waves seem to have a stronger effect in ACD than continuous waves. Regarding intensity and temporal exposure pattern, EMF-biological tissue interaction is not linear in response. Intensity threshold for the induction of biological effects depends on frequency, modulation and temporal exposure pattern with unknown so far mechanisms. Given this complexity, translating such experimental data into possible human exposure guidelines is yet arbitrary.

  8. [Does open access publishing increase the impact of scientific articles? An empirical study in the field of intensive care medicine].

    Science.gov (United States)

    Riera, M; Aibar, E

    2013-05-01

    Some studies suggest that open access articles are more often cited than non-open access articles. However, the relationship between open access and citations count in a discipline such as intensive care medicine has not been studied to date. The present article analyzes the effect of open access publishing of scientific articles in intensive care medicine journals in terms of citations count. We evaluated a total of 161 articles (76% being non-open access articles) published in Intensive Care Medicine in the year 2008. Citation data were compared between the two groups up until April 30, 2011. Potentially confounding variables for citation counts were adjusted for in a linear multiple regression model. The median number (interquartile range) of citations of non-open access articles was 8 (4-12) versus 9 (6-18) in the case of open access articles (p=0.084). In the highest citation range (>8), the citation count was 13 (10-16) and 18 (13-21) (p=0.008), respectively. The mean follow-up was 37.5 ± 3 months in both groups. In the 30-35 months after publication, the average number (mean ± standard deviation) of citations per article per month of non-open access articles was 0.28 ± 0.6 versus 0.38 ± 0.7 in the case of open access articles (p=0.043). Independent factors for citation advantage were the Hirsch index of the first signing author (β=0.207; p=0.015) and open access status (β=3.618; p=0.006). Open access publishing and the Hirsch index of the first signing author increase the impact of scientific articles. The open access advantage is greater for the more highly cited articles, and appears in the 30-35 months after publication. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  9. Increased self-efficacy: the experience of high-intensity exercise of nursing home residents with dementia - a qualitative study.

    Science.gov (United States)

    Olsen, Cecilie Fromholt; Telenius, Elisabeth Wiken; Engedal, Knut; Bergland, Astrid

    2015-09-14

    There has been increasing interest in the use of non-pharmacological interventions, such as physical exercise, to improve the well-being of nursing home residents with dementia. For reasons regarding disease symptoms, persons with dementia might find it difficult to participate in exercise programs. Therefore, it is important to find ways to successfully promote regular exercise for patients in residential care. Several quantitative studies have established the positive effects of exercise on biopsychosocial factors, such as self-efficacy in older people; however, little is known regarding the qualitative aspects of participating in an exercise program among older people with dementia. From the perspective of residents, we explored the experiences of participating in a high-intensity functional exercise program among nursing home residents with dementia. The participants were eight elderly people with mild-to-moderate dementia. We conducted semi-structured interviews one week after they had finished a 10-week supervised high-intensity exercise program. We analyzed the data using an inductive content analysis. Five overreaching and interrelated themes emerged from the interviews: "Pushing the limits," "Being invested in," "Relationships facilitate exercise participation," "Exercise revives the body, increases independence and improves self-esteem" and "Physical activity is a basic human necessity--use it or lose it!" The results were interpreted in light of Bandura's self-efficacy theory. The exercise program seemed to improve self-efficacy through several mechanisms. By being involved, "being invested in" and having something expected of them, the participants gained a sense of empowerment in their everyday lives. The importance of social influences related to the exercise instructor and the exercise group was accentuated by the participants. The nursing home residents had, for the most part, positive experiences with regard to participating in the exercise program

  10. Increased cardiac output and maximal oxygen uptake in response to ten sessions of high intensity interval training.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael M; Namm, Samantha; Fischer, Anthony; Wood, Kimi A

    2018-01-01

    Increases in maximal oxygen uptake (VO2max) are widely reported in response to completion of high intensity interval training (HIIT), yet the mechanism explaining this result is poorly understood. This study examined changes in VO2max and cardiac output (CO) in response to 10 sessions of low-volume HIIT. Participants included 30 active men and women (mean age and VO2max=22.9±5.4 years and 39.6±5.6 mL/kg/min) who performed HIIT and 30 men and women (age and VO2max=25.7±4.5 years and 40.7±5.2 mL/kg/min) who served as non-exercising controls (CON). High intensity interval training consisted of 6-10 s bouts of cycling per session at 90-110 percent peak power output (PPO) interspersed with 75 s recovery. Before and after training, progressive cycling to exhaustion was completed during which CO, stroke volume (SV), and heart rate (HR) were estimated using thoracic impedance. To confirm VO2max attainment, a verification test was completed after progressive cycling at a work rate equal to 110%PPO. Data demonstrated significant improvements in VO2max (2.71±0.63 L/min to 2.86±0.63 L/min, Psessions of HIIT is due to improvements in oxygen delivery.

  11. X-ray-induced chromosome aberrations in Down lymphocytes: an explanation of their increased sensitivity

    International Nuclear Information System (INIS)

    Preston, R.J.

    1981-01-01

    Unstimulated lymphocytes from individuals with Down Syndrome (trisomy 21) are more sensitive to the induction of dicentric and ring aberrations by X rays than normal lymphocytes. Several explanations involving the more rapid rejoining of X-ray--induced lesions in Down cells have been offered. It is shown here that the repair of the DNA damage converted into chromosome aberrations is more rapid in Down cells than normal cells. This more rapid repair results in a higher probability of producing chromosomes aberrations, and hence higher aberration frequencies in Down than normal cells

  12. X-ray-induced chromosome aberrations in Down lymphocytes: an explanation of their increased sensitivity

    International Nuclear Information System (INIS)

    Preston, R.J.

    1981-01-01

    Unstimulated lymphocytes from individuals with Down Syndrome (trisomy 21) are more sensitive to the induction of dicentric and ring aberrations by X rays than normal lymphocytes. Several explanations involving the more rapid rejoining of X-ray-induced lesions in Down cells have been offered. It is shown here that the repair of the DNA damage converted into chromosome aberrations is more rapid in Down cells than normal cells. This more rapid repair results in a higher probability of producing chromosome aberrations, and hence higher aberration frequencies in Down than normal cells

  13. Effects of high-intensity pulse irradiation with linear polarized near-infrared rays and stretching on muscle tone in patients with cerebrovascular disease: a randomized controlled trial.

    Science.gov (United States)

    Takeuchi, Nobuyuki; Takezako, Nobuhiro; Shimonishi, Yuko; Usuda, Shigeru

    2017-08-01

    [Purpose] The purpose of this study was to clarify the influence of high-intensity pulse irradiation with linear polarized near-infrared rays (HI-LPNR) and stretching on hypertonia in cerebrovascular disease patients. [Subjects and Methods] The subjects were 40 cerebrovascular disease patients with hypertonia of the ankle joint plantar flexor muscle. The subjects were randomly allocated to groups undergoing treatment with HI-LPNR irradiation (HI-LPNR group), stretching (stretching group), HI-LPNR irradiation followed by stretching (combination group), and control group (10 subjects each). In all groups, the passive range of motion of ankle dorsiflexion and passive resistive joint torque of ankle dorsiflexion were measured before and after the specified intervention. [Results] The changes in passive range of motion, significant increase in the stretching and combination groups compared with that in the control group. The changes in passive resistive joint torque, significant decrease in HI-LPNR, stretching, and combination groups compared with that in the control group. [Conclusion] HI-LPNR irradiation and stretching has effect of decrease muscle tone. However, combination of HI-LPNR irradiation and stretching has no multiplier effect.

  14. Theoretical calculations of L alpha one x-ray emission intensity ratios for uranium in various matrices: a comparison with experimental values

    International Nuclear Information System (INIS)

    Anderson, L.D.

    1976-01-01

    The U L/sub α1/ x-ray emission intensity ratios (I/sub lambda/sub L//I sub lambda/sub L/, sub 100 percent/sub UO 2 /) in various matrices were calculated using the fundamental parameters formula of Criss and Birks and mass absorption coefficients calculated from a formula developed by Dewey. The use of the intensity ratio made it unnecessary to know the fluorescence yield for the U L/sub III/ level, the probability of emission of the U L/sub α1/ line, and the jump ratios for the three absorption edges of uranium. Also, since an intensity ratio was used, the results are independent of the x-ray tube current and the spectral distribution of the x-ray tube. A method is presented to calculate the intensity ratios for x-ray tube voltages other than the value (45 kV) used in the calculations. The theoretical results are calculated and compared with the experimental results obtained for 141 matrices. Difficulties due to oxidation of some of the metal powders used in the sample preparation, to small concentrations of uranium, and to an excessively large number of elements present in some of the samples resulted in the invalidation of the experimental results for 91 of the matrices. For the remaining 50 matrices, the theoretical and experimental values agreed to within +-5 percent relative error for 36 matrices; to within +-5 percent to +- 10 percent for 7 matrices; to within +-10 percent to +-20 percent for 6 matrices; and was greater than +-20 percent for 1 matrix

  15. Energy dependence of Lα-to-Ll x-ray intensity ratios for Yb and Pb produced by heavy-ion bombardment

    International Nuclear Information System (INIS)

    Gray, T.J.

    1980-01-01

    Measurements of the incident-ion energy dependence of Lα-to-Ll x-ray intensity ratios are reported for protons incident at 0.40 to 2.20 MeV/amu on thin targets of Pb and for 4 He and C ions incident upon Yb. The data are compared to calculations of the Lα-to-Ll ratio which include the effects of alignment of the 2p/sub 3/2/ state of the target

  16. On the separation of split diffuse intensity maxima from a disordered Cu-Au alloy by an X-ray counter method

    International Nuclear Information System (INIS)

    Ohshima, K.I.; Harada, Jimpei; Moss, S.C.

    1986-01-01

    The X-ray diffuse scattering from a disordered Au-24.4 at.% Cu alloy was measured at room temperature to reveal the split diffuse maxima due to short-range ordering (SRO) through the use of a higher-resolution counter method than heretofore employed. Twofold and fourfold splittings of SRO diffuse intensity could be clearly seen at 100, 110 and their equivalent positions in reciprocal space. (orig.)

  17. Increase of (CdSe/ZnS)Cys quantum dot luminescence intensity in the presence of TPPS4 porphyrin

    International Nuclear Information System (INIS)

    Parra, Gustavo G.; Borissevitch, Iouri E.; Oleinikov, Vladimir A.

    2012-01-01

    Full text: Nanocrystal semiconductor particles or Quantum Dots (QD) possess extraordinary photophysical characteristics, such as extreme high fluorescence quantum yield and optical absorption and very narrow fluorescence band, which can be easily shifted by changing of QD particle size. Due to these characteristics, QD is promising for fluorescence cancer diagnostics and photodynamic treatment. The efficiency of these processes can be in- creased by energy transfer between QD and classic fluorescence probes and photosensitizers (PS). In this work we present on the study of the increase of (CdSe/ZnS)Cys quantum dot luminescence intensity, stimulated by interaction with TPPS 4 porphyrin. The optical absorption and steady-state and time-resolved fluorescence techniques were employed. Water soluble QD (CdSe/ZnS) with emission at 580 nm, functionalized with cysteine (Cys), were studied. TPPS 4 porphyrin was used as a stimulator of QD luminescence. All experiments were realized in PBS buffer (pH 7.3; 7.5 mM) in Milli-Q quality water. The TPPS 4 adding into the QD solutions until the 5μM concentration produced an increase in QD luminescence intensity and lifetime, while for TPPS 4 concentrations higher than 20μM the reduction of the fluorescence intensity was observed, the emission spectra and fluorescence decays profile being unchanged. This effect can not be due to the electrostatic interaction between (CdSe/ZnS)Cys and TPPS 4 because both, (CdSe/ZnS)Cys and TPPS 4 , are negatively charged. We suppose that TPPS 4 porphyrin interacts directly with QD (ZnS) shell, reducing the dangling bound number. This reduction decreases, in turn, the probability of nonradiative ways of the excitation energy dissipation. When the majority of dangling bound is occupied by the TPPS 4 molecules, the effect of QD luminescence reduction (quenching) by porphyrin predominates, probably, via the energy transfer from QD to TPPS 4 . However, because of complexity in the systems involving

  18. Quality Assurance Analysis of a Large Multicenter Practice: Does Increased Complexity of Intensity-Modulated Radiotherapy Lead to Increased Error Frequency?

    International Nuclear Information System (INIS)

    Olson, Adam C.; Wegner, Rodney E.; Scicutella, Carol; Heron, Dwight E.; Greenberger, Joel S.; Huq, M. Saiful; Bednarz, Gregory; Flickinger, John C.

    2012-01-01

    Purpose: Error reduction is an important concern in clinical medicine. Intensity-modulated radiotherapy (IMRT) is an important advancement in radiation oncology that increases the complexity of treatment, potentially increasing the error risk. We studied the frequency and severity of errors in a large multicenter practice to ascertain the impact of quality improvement interventions over time, IMRT, and type of practice. Methods and Materials: We analyzed prospective data from three academic and 16 community practice sites with 24,775 courses of radiotherapy (9,210 IMRT courses and 15,565 non-IMRT) between January 2006 and December 2009. All IMRT treatment was performed using one centralized dose planning center for all sites. Results: We prospectively identified various errors or potential errors in 0.14 % vs. 0.40 % of the IMRT vs. non-IMRT courses (13/9,210 vs. 62/15,565, p = 0.0004) and excluding potential errors: 0.03 % for IMRT vs. 0.21% for non-IMRT. We developed the Clinical Radiotherapy Error Severity Scale (CRESS) to classify error severity from 1 to 10, with 1 to 3 for potential or completely correctable errors, 4 to 5 for dose variations 5%. Multivariate analyses of CRESS values, severity >4, and any error (including potential) correlated significantly reduced errors with IMRT (p = 0.0001–0.0024) but found no significant difference between the academic and community practice sites and no change in error frequency over time despite implementation of 39 system-wide policy changes by the centralized quality improvement committee. Conclusions: Despite the increase in complexity with IMRT compared with conventional radiotherapy, it can be delivered with reduced error frequency.

  19. Characterizing transverse coherence of an ultra-intense focused X-ray free-electron laser by an extended Young's experiment

    Directory of Open Access Journals (Sweden)

    Ichiro Inoue

    2015-11-01

    Full Text Available Characterization of transverse coherence is one of the most critical themes for advanced X-ray sources and their applications in many fields of science. However, for hard X-ray free-electron laser (XFEL sources there is very little knowledge available on their transverse coherence characteristics, despite their extreme importance. This is because the unique characteristics of the sources, such as the ultra-intense nature of XFEL radiation and the shot-by-shot fluctuations in the intensity distribution, make it difficult to apply conventional techniques. Here, an extended Young's interference experiment using a stream of bimodal gold particles is shown to achieve a direct measurement of the modulus of the complex degree of coherence of XFEL pulses. The use of interference patterns from two differently sized particles enables analysis of the transverse coherence on a single-shot basis without a priori knowledge of the instantaneous intensity ratio at the particles. For a focused X-ray spot as small as 1.8 µm (horizontal × 1.3 µm (vertical with an ultrahigh intensity that exceeds 1018 W cm−2 from the SPring-8 Ångstrom Compact free-electron LAser (SACLA, the coherence lengths were estimated to be 1.7 ± 0.2 µm (horizontal and 1.3 ± 0.1 µm (vertical. The ratios between the coherence lengths and the focused beam sizes are almost the same in the horizontal and vertical directions, indicating that the transverse coherence properties of unfocused XFEL pulses are isotropic. The experiment presented here enables measurements free from radiation damage and will be readily applicable to the analysis of the transverse coherence of ultra-intense nanometre-sized focused XFEL beams.

  20. Moderate-intensity interval training increases serum brain-derived neurotrophic factor level and decreases inflammation in Parkinson's disease patients.

    Science.gov (United States)

    Zoladz, J A; Majerczak, J; Zeligowska, E; Mencel, J; Jaskolski, A; Jaskolska, A; Marusiak, J

    2014-06-01

    It has been demonstrated that physical training increases serum brain-derived neurotrophic factor (BDNF) in healthy people. The aim of this study was to establish the effect of physical training on the basal serum level of the BDNF in the Parkinson's disease patients (PD patients) in relation to their health status. Twelve PD patients (mean ± S.E.M: age 70 ± 3 years; body mass 70 ± 2 kg; height 163 ± 3 cm) performed a moderate-intensity interval training (three 1-hour training sessions weekly), lasting 8 weeks. Basal serum BDNF in the PD patients before training amounted to 10,977 ± 756 pg x mL(-1) and after 8 weeks of training it has increased to 14,206 ± 1256 pg x mL(-1) (i.e. by 34%, P=0.03). This was accompanied by an attenuation of total Unified Parkinson's Disease Rating Scale (UPDRS) (P=0.01). The training resulted also in a decrease of basal serum soluble vascular cell adhesion molecule 1 (sVCAM-1) (P=0.001) and serum tumor necrosis factor-α (TNF-α) (P=0.03) levels. We have concluded that the improvement of health status of the Parkinson's disease patients after training could be related to the increase of serum BDNF level caused by the attenuated inflammation in those patients.

  1. Increased Brain Glucose Uptake After 12 Weeks of Aerobic High-Intensity Interval Training in Young and Older Adults.

    Science.gov (United States)

    Robinson, Matthew M; Lowe, Val J; Nair, K Sreekumaran

    2018-01-01

    Aerobic exercise training can increase brain volume and blood flow, but the impact on brain metabolism is less known. We determined whether high-intensity interval training (HIIT) increases brain metabolism by measuring brain glucose uptake in younger and older adults. Brain glucose uptake was measured before and after HIIT or a sedentary (SED) control period within a larger exercise study. Study procedures were performed at the Mayo Clinic in Rochester, MN. Participants were younger (18 to 30 years) or older (65 to 80 years) SED adults who were free of major medical conditions. Group sizes were 15 for HIIT (nine younger and six older) and 12 for SED (six younger and six older). Participants completed 12 weeks of HIIT or SED. HIIT was 3 days per week of 4 × 4 minute intervals at over 90% of peak aerobic capacity (VO2peak) with 2 days per week of treadmill walking at 70% VO2peak. Resting brain glucose uptake was measured using 18F-fluorodeoxyglucose positron emission tomography scans at baseline and at week 12. Scans were performed at 96 hours after exercise. VO2peak was measured by indirect calorimetry. Glucose uptake increased significantly in the parietal-temporal and caudate regions after HIIT compared with SED. The gains with HIIT were not observed in all brain regions. VO2peak was increased for all participants after HIIT and did not change with SED. We demonstrate that brain glucose metabolism increased after 12 weeks of HIIT in adults in regions where it is reduced in Alzheimer's disease. Copyright © 2017 Endocrine Society

  2. X-ray power increase from symmetrized wire-array Z-pinch implosions

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Allshouse, G.O.; Marder, B.M.

    1996-01-01

    A systematic experimental study of annular aluminum-wire z-pinches on the Saturn accelerator shows that, for the first time, the measured spatial characteristics and x-ray powers can approach those of two-dimensional, radiation-magneto-hydrodynamic simulations when large numbers of wires are used. Calculations show that the implosion begins to transition from that of individual plasma wires to that of a continuous plasma shell, when the circumferential gap between wires in the array is reduced below 1.4 +1.3/-0.7 mm. This calculated gap coincides with the measured transition of 1.4 ± 0.4 mm between the observed regimes of slow and rapid improvement in power output with decreasing gap. In the plasma-shell regime, x-ray powers in excess of a factor of three over that generated in the plasma-wire region are measured. (author). 5 figs., 16 refs

  3. X-ray power increase from symmetrized wire-array z-pinch implosions

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T.W.L.; Allshouse, G.O.; Marder, B.M. [and others

    1996-08-01

    A systematic experimental study of annular aluminum-wire z-pinches on the Saturn accelerator shows that, for the first time, the measured spatial characteristics and x-ray powers can approach those of two-dimensional, radiation-magneto-hydrodynamic simulations when large numbers of wires are used. Calculations show that the implosion begins to transition from that of individual plasma wires to that of a continuous plasma shell, when the circumferential gap between wires in the array is reduced below 1.4+1.3/-0.7 mm. This calculated gap coincides with the measured transition of 1.4 {+-}0.4 mm between the observed regimes of slow and rapid improvement in power output with decreasing gap. In the plasma shell regime, x-ray powers in excess of a factor of three over that generated in the plasma-wire region are measured.

  4. X-ray power increase from symmetrized wire-array z-pinch implosions

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Allshouse, G.O.; Marder, B.M.

    1996-08-01

    A systematic experimental study of annular aluminum-wire z-pinches on the Saturn accelerator shows that, for the first time, the measured spatial characteristics and x-ray powers can approach those of two-dimensional, radiation-magneto-hydrodynamic simulations when large numbers of wires are used. Calculations show that the implosion begins to transition from that of individual plasma wires to that of a continuous plasma shell, when the circumferential gap between wires in the array is reduced below 1.4+1.3/-0.7 mm. This calculated gap coincides with the measured transition of 1.4 ±0.4 mm between the observed regimes of slow and rapid improvement in power output with decreasing gap. In the plasma shell regime, x-ray powers in excess of a factor of three over that generated in the plasma-wire region are measured

  5. [Research on increasing X-ray protection capability based on photonic crystal technology].

    Science.gov (United States)

    Li, Ping; Zhao, Peng; Zhang, Rui

    2014-06-01

    Light cannot be propagated within the range of photonic crystal band gaps. Based on this unique property, we proposed a method to improve anti-radiation capability through one-dimensional photonic crystal coating. Using transmission matrix method, we determined the appropriate dielectric materials, thickness and periodic numbers of photonic crystals through Matlab programming simulation. Then, compound one-dimensional photonic crystal coating was designed which was of high anti-radiation rate within the range of X-ray. As is shown through simulation experiments, the reflection rate against X-ray was higher than 90 percent, and the desired anti-radiation effect was achieved. Thus, this method is able to help solve the technical problems facing the inorganic lead glass such as thickness, weightiness, costliness, high lead equivalent, low transparency and high cost. This method has won China's national invention patent approval, and the patent number is 201220228549.2.

  6. X-ray power increase from symmetrized wire-array Z-pinch implosions

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T W.L.; Allshouse, G O; Marder, B M [Sandia Labs., Albuquerque, NM (United States); and others

    1997-12-31

    A systematic experimental study of annular aluminum-wire z-pinches on the Saturn accelerator shows that, for the first time, the measured spatial characteristics and x-ray powers can approach those of two-dimensional, radiation-magneto-hydrodynamic simulations when large numbers of wires are used. Calculations show that the implosion begins to transition from that of individual plasma wires to that of a continuous plasma shell, when the circumferential gap between wires in the array is reduced below 1.4 +1.3/-0.7 mm. This calculated gap coincides with the measured transition of 1.4 {+-} 0.4 mm between the observed regimes of slow and rapid improvement in power output with decreasing gap. In the plasma-shell regime, x-ray powers in excess of a factor of three over that generated in the plasma-wire region are measured. (author). 5 figs., 16 refs.

  7. Captopril increases the intensity of monocyte infection by Trypanosoma cruzi and induces human T helper type 17 cells.

    Science.gov (United States)

    Coelho dos Santos, J S; Menezes, C A S; Villani, F N A; Magalhães, L M D; Scharfstein, J; Gollob, K J; Dutra, W O

    2010-12-01

    The anti-hypertensive drug captopril is used commonly to reduce blood pressure of patients with severe forms of Chagas disease, a cardiomyopathy caused by chronic infection with the intracellular protozoan Trypanosoma cruzi. Captopril acts by inhibiting angiotensin-converting enzyme (ACE), the vasopressor metallopeptidase that generates angiotensin II and promotes the degradation of bradykinin (BK). Recent studies in mice models of Chagas disease indicated that captopril can potentiate the T helper type 1 (Th1)-directing natural adjuvant property of BK. Equipped with kinin-releasing cysteine proteases, T. cruzi trypomastigotes were shown previously to invade non-professional phagocytic cells, such as human endothelial cells and murine cardiomyocytes, through the signalling of G protein-coupled bradykinin receptors (B(2) KR). Monocytes are also parasitized by T. cruzi and these cells are known to be important for the host immune response during infection. Here we showed that captopril increases the intensity of T. cruzi infection of human monocytes in vitro. The increased parasitism was accompanied by up-regulated expression of ACE in human monocytes. While T. cruzi infection increased the expression of interleukin (IL)-10 by monocytes significantly, compared to uninfected cells, T. cruzi infection in association with captopril down-modulated IL-10 expression by the monocytes. Surprisingly, studies with peripheral blood mononuclear cells revealed that addition of the ACE inhibitor in association with T. cruzi increased expression of IL-17 by CD4(+) T cells in a B(2) KR-dependent manner. Collectively, our results suggest that captopril might interfere with host-parasite equilibrium by enhancing infection of monocytes, decreasing the expression of the modulatory cytokine IL-10, while guiding development of the proinflammatory Th17 subset. © 2010 The Authors. Clinical and Experimental Immunology © 2010 British Society for Immunology.

  8. Increased objectively assessed vigorous-intensity exercise is associated with reduced stress, increased mental health and good objective and subjective sleep in young adults.

    Science.gov (United States)

    Gerber, Markus; Brand, Serge; Herrmann, Christian; Colledge, Flora; Holsboer-Trachsler, Edith; Pühse, Uwe

    2014-08-01

    The role of physical activity as a factor that protects against stress-related mental disorders is well documented. Nevertheless, there is still a dearth of research using objective measures of physical activity. The present study examines whether objectively assessed vigorous physical activity (VPA) is associated with mental health benefits beyond moderate physical activity (MPA). Particularly, this study examines whether young adults who accomplish the American College of Sports Medicine's (ACSM) vigorous-intensity exercise recommendations differ from peers below these standards with regard to their level of perceived stress, depressive symptoms, perceived pain, and subjective and objective sleep. A total of 42 undergraduate students (22 women, 20 men; M=21.24years, SD=2.20) volunteered to take part in the study. Stress, pain, depressive symptoms, and subjective sleep were assessed via questionnaire, objective sleep via sleep-EEG assessment, and VPA via actigraphy. Meeting VPA recommendations had mental health benefits beyond MPA. VPA was associated with less stress, pain, subjective sleep complaints and depressive symptoms. Moreover, vigorous exercisers had more favorable objective sleep pattern. Especially, they had increased total sleep time, more stage 4 and REM sleep, more slow wave sleep and a lower percentage of light sleep. Vigorous exercisers also reported fewer mental health problems if exposed to high stress. This study provides evidence that meeting the VPA standards of the ACSM is associated with improved mental health and more successful coping among young people, even compared to those who are meeting or exceeding the requirements for MPA. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Conceptual design of a novel instrument for producing intense pulses of 10 ps X-rays for ultra-fast fluorescence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, G.J.

    1996-05-01

    A novel bench-top device for producing intense, fast pulses of x-rays has been designed with 10 ps fwhm (full-width at half-maximum) x-ray pulse width, 120 keV maximum energy, 100 kHz repetition rate, and 1 A peak current onto the x-ray anode. The device includes three sections: (1) an electron gun that generates 5 ns wide pulses of 120 keV electrons at 100 kHz; (2) solenoidal magnetic lenses and deflection plates that focus the electrons onto an aperture plate and sweep the pulsed beam past the aperture, respectively; and (3) a tungsten anode onto which the post-aperture electrons are focused, producing pulses of x-rays. At a sweeping rate of 10{sup 13} V/s, the electron pulses and resulting x-ray pulses are reduced to about 10 ps. The design process used EGUN (an electron optics and gun design program) electron trajectory simulations, including calculation of important space charge effects. When built, this instrument will be used to excite new, fast, bright scintillator samples in crystal or powdered form, allowing fluorescent lifetimes and spectra to be measured with a microchannel PMT. The very narrow 10 ps x-ray pulse width is necessary for accurate measurements of the risetimes of very fast scintillators (e.g., BaF{sub 2}). In addition, the large x-ray flux (1 A peak current) is advantageous when using a reflection grating monochromator to measure decay times at different wavelengths.

  10. Conceptual design of a novel instrument for producing intense pulses of 10 ps X-rays for ultra-fast fluorescence measurements

    International Nuclear Information System (INIS)

    Gruber, G.J.

    1996-05-01

    A novel bench-top device for producing intense, fast pulses of x-rays has been designed with 10 ps fwhm (full-width at half-maximum) x-ray pulse width, 120 keV maximum energy, 100 kHz repetition rate, and 1 A peak current onto the x-ray anode. The device includes three sections: (1) an electron gun that generates 5 ns wide pulses of 120 keV electrons at 100 kHz; (2) solenoidal magnetic lenses and deflection plates that focus the electrons onto an aperture plate and sweep the pulsed beam past the aperture, respectively; and (3) a tungsten anode onto which the post-aperture electrons are focused, producing pulses of x-rays. At a sweeping rate of 10 13 V/s, the electron pulses and resulting x-ray pulses are reduced to about 10 ps. The design process used EGUN (an electron optics and gun design program) electron trajectory simulations, including calculation of important space charge effects. When built, this instrument will be used to excite new, fast, bright scintillator samples in crystal or powdered form, allowing fluorescent lifetimes and spectra to be measured with a microchannel PMT. The very narrow 10 ps x-ray pulse width is necessary for accurate measurements of the risetimes of very fast scintillators (e.g., BaF 2 ). In addition, the large x-ray flux (1 A peak current) is advantageous when using a reflection grating monochromator to measure decay times at different wavelengths

  11. A rapid cosmic-ray increase in BC 3372-3371 from ancient buried tree rings in China.

    Science.gov (United States)

    Wang, F Y; Yu, H; Zou, Y C; Dai, Z G; Cheng, K S

    2017-11-14

    Cosmic rays interact with the Earth's atmosphere to produce 14 C, which can be absorbed by trees. Therefore, rapid increases of 14 C in tree rings can be used to probe previous cosmic-ray events. By this method, three 14 C rapidly increasing events have been found. Plausible causes of these events include large solar proton events, supernovae, or short gamma-ray bursts. However, due to the lack of measurements of 14 C by year, the occurrence frequency of such 14 C rapidly increasing events is poorly known. In addition, rapid increases may be hidden in the IntCal13 data with five-year resolution. Here we report the result of 14 C measurements using an ancient buried tree during the period between BC 3388 and 3358. We found a rapid increase of about 9‰ in the 14 C content from BC 3372 to BC 3371. We suggest that this event could originate from a large solar proton event.

  12. Low-intensity training increases peak arm VO2 by enhancing both convective and diffusive O2 delivery

    DEFF Research Database (Denmark)

    Boushel, R; Ara, I; Gnaiger, E

    2014-01-01

    in prolonged low-intensity training of a small muscle group when the cardiac output capacity is not directly limiting. The purpose of this study was to investigate the relative roles of circulatory and muscle metabolic mechanisms by which prolonged low-intensity exercise training alters regional muscle VO2 ....

  13. Concentration of phenolic compounds is increased in lettuce grown under high light intensity and elevated CO2.

    Science.gov (United States)

    Pérez-López, Usue; Sgherri, Cristina; Miranda-Apodaca, Jon; Micaelli, Francesco; Lacuesta, Maite; Mena-Petite, Amaia; Quartacci, Mike Frank; Muñoz-Rueda, Alberto

    2018-02-01

    The present study was focused on lettuce, a widely consumed leafy vegetable for the large number of healthy phenolic compounds. Two differently-pigmented lettuce cultivars, i.e. an acyanic-green leaf cv. and an anthocyanic-red one, were grown under high light intensity or elevated CO 2 or both in order to evaluate how environmental conditions may affect the production of secondary phenolic metabolites and, thus, lettuce quality. Mild light stress imposed for a short time under ambient or elevated CO 2 concentration increased phenolics compounds as well as antioxidant capacity in both lettuce cvs, indicating how the cultivation practice could enhance the health-promoting benefits of lettuce. The phenolic profile depended on pigmentation and the anthocyanic-red cv. always maintained a higher phenolic amount as well as antioxidant capacity than the acyanic-green one. In particular, quercetin, quercetin-3-O-glucuronide, kaempferol, quercitrin and rutin accumulated under high light or high CO 2 in the anthocyanic-red cv., whereas cyanidin derivatives were responsive to mild light stress, both at ambient and elevated CO 2 . In both cvs total free and conjugated phenolic acids maintained higher values under all altered environmental conditions, whereas luteolin reached significant amounts when both stresses were administered together, indicating, in this last case, that the enzymatic regulation of the flavonoid synthesis could be differently affected, the synthesis of flavones being favored. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. X-ray Power Increase from Symmetrized Wire-Array z-Pinch Implosions on Saturn.*

    Science.gov (United States)

    Sanford, T. W. L.; Allshouse, G. O.; Marder, B. M.; Nash, T. J.; Mock, R. C.; Douglas, M. R.; Spielman, R. B.; Seaman, J. F.; McGurn, J. S.; Jobe, D.; Gilliland, T. L.; Vargas, M.; Struve, K. W.; Stygar, W. A.; Hammer, J. H.; Degroot, J. S.; Eddleman, J. L.; Peterson, D. L.; Whitney, K. G.; Thornhill, J. W.; Pulsifer, P. E.; Apruzese, J. P.; Mosher, D.; Maron, Y.

    1996-11-01

    A systematic experimental study of annular aluminum wire z-pinches on the Saturn accelerator at Sandia National Laboratories shows that, for the first time, many of the measured spatial characteristics and x-ray powers can be correlated to 1D and 2D, radiation-magneto-hydrodynamic code (RMHC) simulations when large numbers of wires are used. Calculations show that the implosion begins to transition from that of individual wire plasmas to that of a continuous plasma shell when the circumferential gap between wires in the array is reduced below 1.4 +1.3/-0.7 mm. This calculated gap coincides with the measured transition of 1.4±0.4 mm between the observed regimes of slow and rapid improvement in power output with decreasing gap. In the plasma-shell regime, x-ray power has been more than tripled over that generated in the wire-plasma regime. In the full paper, measured characteristics in the plasma-shell regime are compared with 2D, 1- and 20-mm axial length simulations of the implosion using a multi-photon-group Lagrangian RMHC^1 and a three-temperature Eulerian RMHC,^2 respectively. ^1J.H. Hammer, et al., Phys. Plasmas 3, 2063 (1996). ^2D.L. Peterson, et al., Phys. Plasmas 3, 368 (1996). Work supported by U.S. DOE Contract No. DE-AC04-94AL85000.

  15. Prediction of galactic cosmic ray intensity variation for a few (up to 10-12 years ahead on the basis of convection-diffusion and drift model

    Directory of Open Access Journals (Sweden)

    L. I. Dorman

    2005-11-01

    Full Text Available We determine the dimension of the Heliosphere (modulation region, radial diffusion coefficient and other parameters of convection-diffusion and drift mechanisms of cosmic ray (CR long-term variation, depending on particle energy, the level of solar activity (SA and general solar magnetic field. This important information we obtain on the basis of CR and SA data in the past, taking into account the theory of convection-diffusion and drift global modulation of galactic CR in the Heliosphere. By using these results and the predictions which are regularly published elsewhere of expected SA variation in the near future and prediction of next future SA cycle, we may make a prediction of the expected in the near future long-term cosmic ray intensity variation. We show that by this method we may make a prediction of the expected in the near future (up to 10-12 years, and may be more, in dependence for what period can be made definite prediction of SA galactic cosmic ray intensity variation in the interplanetary space on different distances from the Sun, in the Earth's magnetosphere, and in the atmosphere at different altitudes and latitudes.

  16. Spectroscopic investigations of hard x-ray emission from 120 ps laser-produced plasmas at intensities near 1017 W cm-2

    International Nuclear Information System (INIS)

    Dunn, J.; Young, B.K.F.; Osterheld, A.L.; Foord, M.E.; Walling, R.S.; Stewart, R.E.; Faenov, A.Y.

    1995-11-01

    Spectroscopic investigations of the x-ray emission of plasmas heated by 120 ps, frequency doubled pulses from the JANUS Nd: glass laser are presented. High Z K-shell spectra emitted from slab targets heated to near 10 17 W cm -2 intensity are investigated. High resolution (γ/Δγ>5000) x-ray spectra of multicharged ions of H-like Ti, Co, Ni, Cu, and also H-like Sc in the spectral range 1.5--3.0 angstrom are obtained in single laser shots using a spherically bent Mica crystal spectrograph with a 186 mm radius of curvature. The spectra- have one dimensional spatial resolution of about 25μm and indicate that the size of the emission zone of the resonance, transitions is 2 keV and density∼10 22 cm -3 . These experiments demonstrate that with modest laser energy, plasmas heated by high-intensity 120 ps lasers provide a very bright source of hard ∼8 keV x-ray emission

  17. Conceptual design of a novel instrument for producing intense pulses of 10 ps X-rays for ultra-fast fluorescence measurements

    International Nuclear Information System (INIS)

    Gruber, G.J.; Derenzo, S.E.

    1996-01-01

    A novel bench-top device for producing intense, fast pulses of x-rays has been designed with 10 ps fwhm (full-width at half-maximum) x-ray pulse width, 120 keV maximum energy, 100 kHz repetition rate, and 1 A peak current onto the x-ray anode. The device includes three sections: (1) an electron gun that generates 5 ns wide pulses of 120 keV electrons at 100 kHz; (2) solenoidal magnetic lenses and deflection plates that focus the electrons onto an aperture plate and sweep the pulsed beam past the aperture, respectively; and (3) a tungsten anode onto which the post-aperture electrons are focused, producing pulses of x-rays. Using solenoidal magnetic lenses with a cur-rent density of 150 A·turns/cm 2 to focus the electron beam, a deflection plate dV/dt of 10 13 V/s is needed to achieve electron pulse widths of about 10 ps. The design process used EGUN (an electron optics and gun design program) electron trajectory simulations, including calculation of important space charge effects. When built, this instrument will be used to excite scintillator samples in crystal or powdered form, allowing fluorescent lifetimes and spectra to be measured with a microchannel PMT. The very narrow 10 ps x-ray pulse width is necessary for accurate measurements of the risetimes of very fast scintillators, (e.g., BaF 2 ). In addition, the large x-ray flux (1 A peak current) is advantageous when using a reflection grating monochromator to measure decay times at different wavelengths

  18. Effects of low intensity pulsed ultrasound with and without increased cortical porosity on structural bone allograft incorporation

    Directory of Open Access Journals (Sweden)

    Ehrhart Nicole

    2008-05-01

    Full Text Available Abstract Background Though used for over a century, structural bone allografts suffer from a high rate of mechanical failure due to limited graft revitalization even after extended periods in vivo. Novel strategies that aim to improve graft incorporation are lacking but necessary to improve the long-term clinical outcome of patients receiving bone allografts. The current study evaluated the effect of low-intensity pulsed ultrasound (LIPUS, a potent exogenous biophysical stimulus used clinically to accelerate the course of fresh fracture healing, and longitudinal allograft perforations (LAP as non-invasive therapies to improve revitalization of intercalary allografts in a sheep model. Methods Fifteen skeletally-mature ewes were assigned to five experimental groups based on allograft type and treatment: +CTL, -CTL, LIPUS, LAP, LIPUS+LAP. The +CTL animals (n = 3 received a tibial ostectomy with immediate replacement of the resected autologous graft. The -CTL group (n = 3 received fresh frozen ovine tibial allografts. The +CTL and -CTL groups did not receive LAP or LIPUS treatments. The LIPUS treatment group (n = 3, following grafting with fresh frozen ovine tibial allografts, received ultrasound stimulation for 20 minutes/day, 5 days/week, for the duration of the healing period. The LAP treatment group (n = 3 received fresh frozen ovine allografts with 500 μm longitudinal perforations that extended 10 mm into the graft. The LIPUS+LAP treatment group (n = 3 received both LIPUS and LAP interventions. All animals were humanely euthanized four months following graft transplantation for biomechanical and histological analysis. Results After four months of healing, daily LIPUS stimulation of the host-allograft junctions, alone or in combination with LAP, resulted in 30% increases in reconstruction stiffness, paralleled by significant increases (p Conclusion The current study has demonstrated in a large animal model the potential of both LIPUS and LAP

  19. Baker's yeast beta glucan supplementation increases salivary IgA and decreases cold/flu symptomatic days after intense exercise.

    Science.gov (United States)

    McFarlin, Brian K; Carpenter, Katie C; Davidson, Tiffany; McFarlin, Meredith A

    2013-09-01

    Strenuous exercise, such as running a marathon, is known to suppress mucosal immunity for up to 24 hr, which can increase the risk of developing an upper respiratory tract infection (URTI) and reduced performance capacity (Allgrove JE, Geneen L, Latif S, Gleeson M. Influence of a fed or fasted state on the s-IgA response to prolonged cycling in active men and women. Int J Sport Nutr Exerc Metab. 2009;19(3):209-221; Barrett B, Locken K, Maberry R, Schwamman J, Brown R, Bobula J, Stauffacher EA. The Wisconsin Upper Respiratory Symptom Survey (WURSS): a new research instrument for assessing the common cold. J Fam Pract. 2002;51(3):265; Carpenter KC, Breslin WL, Davidson T, Adams A, McFarlin BK. Baker's yeast beta glucan supplementation increases monocytes and cytokines post-exercise: implications for infection risk? Br J Nutr. 2012;1-9). While many dietary interventions have been used to combat postexercise immune suppression, most have been ineffective. The key purpose of this study was to determine if baker's yeast β-glucan (BG) could positively affect the immune system of individuals undergoing intense exercise stress using two experiments. In the first (E1; N = 182 men and women), BG was compared to placebo supplementation for the incidence of URTI symptoms for 28 days postmarathon. In the second (E2; N = 60 men and women) changes in salivary immunoglobulin A (IgA) were evaluated after 50-min of strenuous cycling when participants had been supplemented for 10 days with either BG (250 mg/day) or placebo (rice flour). For E1, subjects reported URTI symptoms using a daily health log. For E2, saliva was collected prior to, immediately, and 2-hr postexercise using a salivette. Data for E1 and E2 were analyzed using separate analyses of variance (ANOVAs) with repeated measures (p flu symptom days postmarathon compared to placebo (p = .026). In E2, BG was associated with a 32% increase in salivary IgA (p = .048) at 2 hr after exercise compared to placebo. In summary

  20. The impact of the in-orbit background and the X-ray source intensity on the centroiding accuracy of the Swift X-ray telescope

    CERN Document Server

    Ambrosi, R M; Hill, J; Cheruvu, C; Abbey, A F; Short, A D T

    2002-01-01

    The optical components of the Swift Gamma Ray Burst Explorer X-ray Telescope (XRT), consisting of the JET-X spare flight mirror and a charge coupled device of the type used in the EPIC program, were used in a re-calibration study carried out at the Panter facility, which is part of the Max Planck Institute for Extraterrestrial Physics. The objective of this study was to check the focal length and the off axis performance of the mirrors and to show that the half energy width (HEW) of the on-axis point spread function (PSF) was of the order of 16 arcsec at 1.5 keV (Nucl. Instr. and Meth. A 488 (2002) 543; SPIE 4140 (2000) 64) and that a centroiding accuracy better that 1 arcsec could be achieved within the 4 arcmin sampling area designated by the Burst Alert Telescope (Nucl. Instr. and Meth. A 488 (2002) 543). The centroiding accuracy of the Swift XRT's optical components was tested as a function of distance from the focus and off axis position of the PSF (Nucl. Instr. and Meth. A 488 (2002) 543). The presence ...

  1. Intense resistance exercise induces early and transient increases in ryanodine receptor 1 phosphorylation in human skeletal muscle.

    Directory of Open Access Journals (Sweden)

    Sebastian Gehlert

    Full Text Available BACKGROUND: While ryanodine receptor 1 (RyR1 critically contributes to skeletal muscle contraction abilities by mediating Ca²⁺ion oscillation between sarcoplasmatic and myofibrillar compartments, AMP-activated protein kinase (AMPK senses contraction-induced energetic stress by phosphorylation at Thr¹⁷². Phosphorylation of RyR1 at serine²⁸⁴³ (pRyR1Ser²⁸⁴³ results in leaky RyR1 channels and impaired Ca²⁺homeostasis. Because acute resistance exercise exerts decreased contraction performance in skeletal muscle, preceded by high rates of Ca²⁺-oscillation and energetic stress, intense myofiber contractions may induce increased RyR1 and AMPK phosphorylation. However, no data are available regarding the time-course and magnitude of early RyR1 and AMPK phosphorylation in human myofibers in response to acute resistance exercise. PURPOSE: Determine the effects and early time-course of resistance exercise on pRyR1Ser²⁸⁴³ and pAMPKThr¹⁷² in type I and II myofibers. METHODS: 7 male subjects (age 23±2 years, height: 185±7 cm, weight: 82±5 kg performed 3 sets of 8 repetitions of maximum eccentric knee extensions. Muscle biopsies were taken at rest, 15, 30 and 60 min post exercise. pRyR1Ser²⁸⁴³ and pAMPKThr¹⁷² levels were determined by western blot and semi-quantitative immunohistochemistry techniques. RESULTS: While total RyR1 and total AMPK levels remained unchanged, RyR1 was significantly more abundant in type II than type I myofibers. pRyR1Ser²⁸⁴³ increased 15 min and peaked 30 min (p<0.01 post exercise in both myofiber types. Type I fibers showed relatively higher increases in pRyR1Ser²⁸⁴³ levels than type II myofibers and remained elevated up to 60 min post resistance exercise (p<0.05. pAMPKThr¹⁷² also increased 15 to 30 min post exercise (p<0.01 in type I and II myofibers and in whole skeletal muscle. CONCLUSION: Resistance exercise induces acutely increased pRyR1Ser²⁸⁴³ and

  2. Application of gamma rays for increasing the productivity of xylitol from rice straw by candida teleprocess and candida guilieliermondii

    International Nuclear Information System (INIS)

    Abouzeid, A.A.; El-zawahry, Y.A.; El-mongy, T.M.; El-Fouly, M.Z.; Abd El-aziz, A.B.

    2005-01-01

    Irradiating the rice straw with high dose level of gamma rays (100-KGy) after being treated with diluted sulphuric acid increased the xylitol yields from the hydrolysates to 43.2 and 45.0 g/l out of 63.0 g/l xylose by Candida tropical and Candida guilliermondii, respectively. Meanwhile, irradiating C. tropical is and C. guilliermondii with low dose levels (0.25 and 0.5 KGy, respectively) before being inoculated in artificial medium, containing 150 g/l xylose, increased the yields of xylitol by the irradiated species. On the contrary, the produced xylitol was decreased sharply in case of isolates irradiated with 1 KGy especially C. tropical is, which showed less resistance to gamma rays recording. D 1 0, value 1.225 compared with 1.608 for C. guilliermondii. Sub-lethal dose of gamma rays (10 and 8 KGy) shrank C. guilliermondii cells and their sh,ape became irregular while C. tropical is cells formed small cottony fibres structure on the external surface of the cell wall, respectively. Meanwhile, lethal radiation doses-(l l and 9 KGy) caused deformation of the vegetative cells of both isolates. Many cells were enlarged, the cell walls of many others were ruptured and the internal contents were released outside the cells. Complete lyses of some cells-was also observed

  3. X-ray emission from high-intensity interaction of picosecond and subnanosecond laser pulses with solid targets

    Czech Academy of Sciences Publication Activity Database

    Badziak, J.; Jabloňski, S.; Makowski, J.; Parys, P.; Ryc, L.; Vankov, A. B.; Wolowski, J.; Woryna, E.; Juha, Libor; Krása, Josef

    2002-01-01

    Roč. 32, 1-2 (2002), s. 41-46 ISSN 0078-5466 Grant - others:KBN(PL) 2PO3B08219 Institutional research plan: CEZ:AV0Z1010921 Keywords : soft x-ray emission * laser produced plasma * 1-ps and 0.5ns laser pulses Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.291, year: 2002

  4. Towards tabletop production of intense quasimonochromatic X-ray beams using small 2-20 MeV accelerators

    International Nuclear Information System (INIS)

    Avakian, R.O.; Ispirian, K.A.

    2004-01-01

    Full text: The existing synchrotron radiation sources and the fourth generation x-ray sources, which are projected at SLAC, USA, and DESY, Germany, are very expensive. For this reason the search of the novel and cheaper sources using various types of radiation produced by 5-20 MeV electrons available at many hospitals, universities and firms in various countries is of great interest. In this article a review of the physics, history, new theoretical and experimental results and of some applications is given with a purpose to consider the possibilities of construction of small tabletop sources of quasimonochromatic X-ray photon beams necessary for scientific, industrial, medicine and other applications. Simple formulae for almost all types of radiation are given with the help of which one can estimate the expected useful yield and background. PACS: 41.60.-m; 43.35.Ty; 61.85+p;m 78.67.Pt; 78.70.-g. Key words: Bremsstrahlung/Cherenkov radiation/ Transition radiation / Parametric X-ray radiation / Channeling radiation/ Compton scattering

  5. Development of a high energy resolution magnetic bolometer for the determination of photon emission intensities by gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Rodrigues, M.

    2007-12-01

    In this research thesis, a first chapter describes the metrological difficulties for the determination of radionuclide photon emission intensities. Then, it discusses the understanding and the required tools for the computing of a magnetic bolometer signal with respect to the different operation parameters and to the sensor geometry. The author describes the implementation of the experimental device and its validation with a first sensor. The new sensor is then optimised for the measurement of photon emission intensities with a good efficiency and a theoretical energy resolution less than 100 eV up to 200 keV. The sensor's detection efficiency and operation have been characterized with a 133 Ba source. The author finally presents the obtained results

  6. Increasing physical activity for veterans in the Mental Health Intensive Case Management Program: A community-based intervention.

    Science.gov (United States)

    Harrold, S Akeya; Libet, Julian; Pope, Charlene; Lauerer, Joy A; Johnson, Emily; Edlund, Barbara J

    2018-04-01

    Individuals with severe mental illness (SMI), experience increased mortality-20 years greater disparity for men and 15 years greater disparity for women-compared to the general population (Thornicroft G. Physical health disparities and mental illness: The scandal of premature mortality. Br J Psychiatr. 2011;199:441-442). Numerous factors contribute to premature mortality in persons with SMI, including suicide and accidental death (Richardson RC, Faulkner G, McDevitt J, Skrinar GS, Hutchinson D, Piette JD. Integrating physical activity into mental health services for persons with serious mental illness. Psychiatr Serv. 2005;56(3):324-331; Thornicroft G. Physical health disparities and mental illness: The scandal of premature mortality. Br J Psychiatr. 2011;199:441-442), but research has shown that adverse health behaviors-including smoking, low rate of physical activity, poor diet, and high alcohol consumption-also significantly contribute to premature deaths (Jones J. Life expectancy in mental illness. Psychiatry Services. 2010. Retrieved from http://psychcentral.com/news/2010/07/13/life-expectancy-in-mental-illness). This quality improvement (QI) project sought to improve health and wellness for veterans in the Mental Health Intensive Case Management Program (MHICM), which is a community-based intensive program for veterans with SMI at risk for decompensation and frequent hospitalizations. At the time of this QI project, the program had 69 veterans who were assessed and treated weekly in their homes. The project introduced a pedometer steps intervention adapted from the VA MOVE! Program-a physical activity and weight management program-with the addition of personalized assistance from trained mental health professionals in the veteran's home environment. Because a large percentage of the veterans in the MHICM program had high blood pressure and increased weight, these outcomes were the focus of this project. Through mental health case management involvement and

  7. Purification and Concentration of PCR Products Leads to Increased Signal intensities with Fewer Allelic Drop-Outs and Artifacts

    DEFF Research Database (Denmark)

    Maria Irlund Pedersen, Line; Stangegaard, Michael; Mogensen, Helle Smidt

    2011-01-01

    and the quality of the DNA profiles without re-amplification of the sample. We have validated and implemented an automated method to purify and 2-fold concentrate PCR products resulting in allelic peaks with higher intensity (a median height across all loci from 130 to 404 RFU), fewer allelic dropouts...

  8. Bone repair of the periapical lesions treated or not with low intensity laser (λ = 904 nm).(An X-ray study in human)

    International Nuclear Information System (INIS)

    Sousa, Gerdal Roberto de

    2001-01-01

    The purpose of this study was to evaluate the influence of low intensity laser on the bone repair over periapical lesions of dental elements. Fifteen patients with a total of eighteen periapical lesions were selected and divided into two groups. Lesions of the control group were submitted to endodontic treatment and/or periapical surgery and the lesions of the experimental laser group, were submitted to the same procedures of the first group but also irradiated by low intensity laser. It was used a 904 nm wavelength laser GaAs, employing 11 mW of power delivered by a fiber optic system, irradiation continuos and contact mode, using a fluency of 9 J/cm 2 . The mentioned treatment was repeated for 10 sessions with intervals of 72 hours between each session. Bone repair was evaluated through lesion measurements, which were accessed from the X ray pictures using a time and then, were also statistically analyzed. Results showed a significant difference between lased and control groups (p<0,10), emphasizing that for the laser group presented a significant reduction of the lesions area, confirmed by X ray. (author)

  9. Valence-electron configuration of Fe, Cr, and Ni in binary and ternary alloys from Kβ -to- Kα x-ray intensity ratios

    Science.gov (United States)

    Han, I.; Demir, L.

    2009-11-01

    Kβ -to- Kα x-ray intensity ratios of Fe, Cr, and Ni have been measured in pure metals and in alloys of FexNi1-x ( x=0.8 , 0.7, 0.6, 0.5, 0.4, 0.3, and 0.2), NixCr1-x ( x=0.8 , 0.6, 0.5, 0.4, and 0.2), FexCr1-x ( x=0.9 , 0.7, and 0.5), and FexCryNi1-(x+y) ( x=0.7-y=0.1 , x=0.5-y=0.2 , x=0.4-y=0.3 , x=0.3-y=0.3 , x=0.2-y=0.2 , and x=0.1-y=0.2 ) following excitation by 22.69 keV x rays from a 10 mCi C109d radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kβ -to- Kα x-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s,4p states of individual metal atoms.

  10. Relativistic self-focusing of ultra-high intensity X-ray laser beams in warm quantum plasma with upward density profile

    International Nuclear Information System (INIS)

    Habibi, M.; Ghamari, F.

    2014-01-01

    The results of a numerical study of high-intensity X-ray laser beam interaction with warm quantum plasma (WQP) are presented. By means of an upward ramp density profile combined with quantum factors specially the Fermi velocity, we have demonstrated significant relativistic self-focusing (RSF) of a Gaussian electromagnetic beam in the WQP where the Fermi temperature term in the dielectric function is important. For this purpose, we have considered the quantum hydrodynamics model that modifies refractive index of inhomogeneous WQPs with the inclusion of quantum correction through the quantum statistical and diffraction effects in the relativistic regime. Also, to better illustration of the physical difference between warm and cold quantum plasmas and their effect on the RSF, we have derived the envelope equation governing the spot size of X-ray laser beam in Q-plasmas. In addition to the upward ramp density profile, we have found that the quantum effects would be caused much higher oscillation and better focusing of X-ray laser beam in the WQP compared to that of cold quantum case. Our computational results reveal the importance of the use of electrons density profile and Fermi speed in enhancing self-focusing of laser beam

  11. X-ray spectroscopy of a thin foil plasma produced by a short-pulse high-intensity laser

    International Nuclear Information System (INIS)

    Audebert, P.; Nagels, V.; Geindre, J.P.; Dorchies, F.; Peyrusse, O.; Gary, S.; Girard, F.; Shepherd, R.; Gauthier, J.C.; Chenais-Popovics, C.

    2003-01-01

    High density and temperature plasmas have been generated by irradiating thin foils of various elements with a high-energy subpicosecond laser pulse. The X-ray emission duration was studied by time-resolved X-ray spectroscopy. Frequency domain interferometry provided a measurement of the hydrodynamic expansion of the back of the foil as a function of time. The effect of longitudinal temperature gradients, i.e., gradients perpendicular to the surface, were decreased using very thin foil targets. Additionally, radial gradients effects, i.e., gradients parallel to the surface, were limited by using a 50 μm pinhole on target. The Al, Se and Sm spectra, recorded in the range 7.7-8 Angst. using a conical crystal spectrometer coupled to an 800 fs resolution streak camera, lasted a few picoseconds. Sm spectra showed no spectral features in this wavelength range, providing a spectrally homogeneous backlighter for future experiments. The main features of the experimental time-resolved spectra have been well reproduced with one-dimensional hydrodynamic simulations of the free expansion of a plasma heated at a given initial temperature obtained from the expansion velocity of the rear critical surface of the plasma

  12. Role of Fluorescence yields, Coster–Kronig transitions and ionization theories on L X-ray intensity ratios of Au

    International Nuclear Information System (INIS)

    Mohan, Harsh; Kumar Jain, Arvind; Kaur, Gurpreet; Singh, Parjit S.; Sharma, Sunita

    2012-01-01

    The inner-shell vacancy decay process is consisting of radiative and non-radiative transitions. These investigations have been developing over the last four decades, resulting in close and stringent comparisons of the measured values with the predictions of theoretical models. In view of the current state of affairs, we report in this paper the role of Fluorescence yields, Coster–Kronig transitions and prevailing ionization theories on L X-ray production from Au using low energy protons. Their contribution to these phenomena and current growth will be highlighted. Prospects for supplementary effort will also be discussed. - Highlights: ► New data for L X-ray production from Au using low energy protons are reported. ► Effects of Fluorescence yields and Coster–Kronig transitions on it are analyzed. ► Stringent comparison of measured values with theoretical models has been presented.► Their contribution to these phenomena and current growth has been highlighted. ► Prospects for supplementary effort are discussed.

  13. Fission products determination in high activity waste solution by wavelength dispersive X-ray fluorescence spectral interference correction by intensity ratio

    International Nuclear Information System (INIS)

    Sato, I.M.

    1988-01-01

    Fission products Se, Rb, Y, Zr, Mo, Ru, Rh, Pd, Te, Cd, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu and Gd were determined in simulated high activity radioactive waste solution by wavelength dispersive X-ray fluorescence spectrometry without chemical separation. Thin layer technique was employed for the sample preparation. For the L spectral lines, the absorption effect was verified by Rasberry-Heinrich, Lucas Tooth-Pyne and Lachance-Trail relations. This effect was quantified and corrected accordingly. The spectral interferences of Kα and/or Lα lines of Y, Zr, Mo, La, Ce, Pr, Nd, Sm, Eu and Gd elements were eliminated by the intensity ratio method. The overlapping of up to three analytical lines was corrected by applying this method. The concentration influence of the interfering element on the intensity ratio values as well the efficiency of the correction method were investigated in order to assure that no systematic or residual error, resulting from the correction, affect the actual fluorescent intensity determination. The results is compared with the data obtained from measurements of free lines of spectral interference and also with those obtained by the linear equation system. Fission products determination presented a precision in the range of 0.1 to 5.0% and an accuracy of up to ± 7.0% the results are compared with those obtained by neutron activation analysis and inductively coupled plasma - atomic emission spectrometry. Leaching data, when radioactive waste is incorporated in cement matrix, were attempted by X-ray fluorescence technique. For two years leaching period, leaching rate and diffusion coefficient data of cesium were determined. The results obtained agree with those obtained by γ-spectromety. (author) [pt

  14. SLAC/DESY International Workshop on Interactions of Intense Sub-Picosecond X-Rays with Matter, Stanford, CA, January 23-24, 1997

    International Nuclear Information System (INIS)

    Tatchyn, Roman

    1998-01-01

    This is the proceedings volume of the 1997 SLAC/DESY International Workshop on Interactions of Intense Sub-picosecond X-Ray Pulses with Matter. The workshop theme evolved out of design and R and D studies, undertaken at SLAC, DESY, and elsewhere [1,2], of the new class of linac-driven X-Ray Free Electron Lasers (XRFELs) operating with photocathode-based, low-emittance electron beams in the Self-Amplified Spontaneous Emission (SASE) regime [3]. It can be noted that, following the conclusion of the workshop, funded design study reports on R and D facilities based on these novel sources have been completed and published by both laboratories [4,5]. Topical significance was imparted to the workshop agenda by a series of prior workshops organized to explore scientific and technological applications of linac driven XRFELs [6,7,8,9]. These served to highlight underlying concerns regarding the potential loading effects of the highly intense radiation pulses from this new class of light source on the instrumentation, samples, and experimental phenomena being considered. The primary objectives of the workshop were: (a) to provide tutorial overviews of existing theoretical, numerical, and experimental techniques in the study of interactions of intense, ultra-short radiation pulses with matter, and of their applicability to the parameter regimes of the SLAC and DESY XRFELs; (b) to discuss practical optics and instrumentation issues related to peak and average power density loading; (c) to identify and explore novel concepts and design approaches, with an emphasis on optical instrumentation and experimental physics; (d) to formulate independent or collaborative R and D programs and activities in the areas of theory, numerical simulation, and experimental physics relevant to the linac-driven XRFEL parameter regime

  15. Phase contrast imaging: Effect of increased object-detector distances at X-ray diagnostic and megavoltage energies

    Energy Technology Data Exchange (ETDEWEB)

    Loveland, J.; Gundogdu, O. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Morton, E. [Rapiscan Systems, Units 2,3,4, Radnor Park Trading Estate, Congleton, Cheshire CW12 4XJ (United Kingdom); Wells, K. [CVSSP, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Bradley, D.A., E-mail: d.a.bradley@surrey.ac.uk [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2011-10-01

    The effect of varying object to detector separation at constant and varying magnification has been investigated at an accelerating potential of 30 kVp. Edge-contrast enhancement provided by phase effects was investigated for a drinking straw and found to provide up to 2.52{+-}0.02x the contrast for a PVC Heaviside step function. An optimum magnification of 1.5x was found to apply for the microfocus X-ray tube setup used. Imaging at nominal megavoltage energies was investigated using a Rapiscan Systems Eagle M4500 series scanner. For a fixed source-detector separation, increased magnification improved edge contrast and spatial resolution.

  16. Phase contrast imaging: Effect of increased object-detector distances at X-ray diagnostic and megavoltage energies

    International Nuclear Information System (INIS)

    Loveland, J.; Gundogdu, O.; Morton, E.; Wells, K.; Bradley, D.A.

    2011-01-01

    The effect of varying object to detector separation at constant and varying magnification has been investigated at an accelerating potential of 30 kVp. Edge-contrast enhancement provided by phase effects was investigated for a drinking straw and found to provide up to 2.52±0.02x the contrast for a PVC Heaviside step function. An optimum magnification of 1.5x was found to apply for the microfocus X-ray tube setup used. Imaging at nominal megavoltage energies was investigated using a Rapiscan Systems Eagle M4500 series scanner. For a fixed source-detector separation, increased magnification improved edge contrast and spatial resolution.

  17. Non-equilibrium Modeling of the Fe XVII 3C/3D Line Ratio in an Intense X-Ray Free-Electron Laser Excited Plasma

    Science.gov (United States)

    Loch, S. D.; Ballance, C. P.; Li, Y.; Fogle, M.; Fontes, C. J.

    2015-03-01

    Recent measurements using an X-ray Free Electron Laser (XFEL) and an Electron Beam Ion Trap at the Linac Coherent Light Source facility highlighted large discrepancies between the observed and theoretical values for the Fe xvii 3C/3D line intensity ratio. This result raised the question of whether the theoretical oscillator strengths may be significantly in error, due to insufficiencies in the atomic structure calculations. We present time-dependent spectral modeling of this experiment and show that non-equilibrium effects can dramatically reduce the predicted 3C/3D line intensity ratio, compared with that obtained by simply taking the ratio of oscillator strengths. Once these non-equilibrium effects are accounted for, the measured line intensity ratio can be used to determine a revised value for the 3C/3D oscillator strength ratio, giving a range from 3.0 to 3.5. We also provide a framework to narrow this range further, if more precise information about the pulse parameters can be determined. We discuss the implications of the new results for the use of Fe xvii spectral features as astrophysical diagnostics and investigate the importance of time-dependent effects in interpreting XFEL-excited plasmas.

  18. Constrained Maximum Likelihood Estimation of Relative Abundances of Protein Conformation in a Heterogeneous Mixture from Small Angle X-Ray Scattering Intensity Measurements

    Science.gov (United States)

    Onuk, A. Emre; Akcakaya, Murat; Bardhan, Jaydeep P.; Erdogmus, Deniz; Brooks, Dana H.; Makowski, Lee

    2015-01-01

    In this paper, we describe a model for maximum likelihood estimation (MLE) of the relative abundances of different conformations of a protein in a heterogeneous mixture from small angle X-ray scattering (SAXS) intensities. To consider cases where the solution includes intermediate or unknown conformations, we develop a subset selection method based on k-means clustering and the Cramér-Rao bound on the mixture coefficient estimation error to find a sparse basis set that represents the space spanned by the measured SAXS intensities of the known conformations of a protein. Then, using the selected basis set and the assumptions on the model for the intensity measurements, we show that the MLE model can be expressed as a constrained convex optimization problem. Employing the adenylate kinase (ADK) protein and its known conformations as an example, and using Monte Carlo simulations, we demonstrate the performance of the proposed estimation scheme. Here, although we use 45 crystallographically determined experimental structures and we could generate many more using, for instance, molecular dynamics calculations, the clustering technique indicates that the data cannot support the determination of relative abundances for more than 5 conformations. The estimation of this maximum number of conformations is intrinsic to the methodology we have used here. PMID:26924916

  19. Amorphous to crystalline phase transition in carbon induced by intense femtosecond x-ray free-electron laser pulses

    Czech Academy of Sciences Publication Activity Database

    Gaudin, J.; Peyrusse, O.; Chalupský, Jaromír; Toufarová, Martina; Vyšín, Luděk; Hájková, Věra; Sobierajski, R.; Burian, Tomáš; Dastjani-Farahani, S.; Graf, A.; Amati, M.; Gregoratti, L.; Hau-Riege, S.P.; Hoffmann, G.; Juha, Libor; Krzywinski, J.; London, R.A.; Moeller, S.; Sinn, H.; Schorb, S.; Störmer, M.; Tschentscher, T.; Vorlíček, Vladimír; Vu, H.; Bozek, J.; Bostedt, C.

    2012-01-01

    Roč. 86, č. 2 (2012), "024103-1"-"024103-7" ISSN 1098-0121 R&D Projects: GA ČR(CZ) GAP108/11/1312; GA ČR GAP205/11/0571; GA ČR GAP208/10/2302; GA AV ČR IAAX00100903; GA MŠk EE.2.3.20.0087 Grant - others:OP VK 2 LaserGen(XE) CZ.1.07/2.3.00/20.0087 Institutional research plan: CEZ:AV0Z10100523 Keywords : amorphous carbon * phase transition * graphitization * x-ray laser * free-electron laser Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.767, year: 2012

  20. Suppression of intensity transition artifacts in statistical x-ray computer tomography reconstruction through Radon inversion initialization

    International Nuclear Information System (INIS)

    Zbijewski, Wojciech; Beekman, Freek J.

    2004-01-01

    Statistical reconstruction (SR) methods provide a general and flexible framework for obtaining tomographic images from projections. For several applications SR has been shown to outperform analytical algorithms in terms of resolution-noise trade-off achieved in the reconstructions. A disadvantage of SR is the long computational time required to obtain the reconstructions, in particular when large data sets characteristic for x-ray computer tomography (CT) are involved. As was shown recently, by combining statistical methods with block iterative acceleration schemes [e.g., like in the ordered subsets convex (OSC) algorithm], the reconstruction time for x-ray CT applications can be reduced by about two orders of magnitude. There are, however, some factors lengthening the reconstruction process that hamper both accelerated and standard statistical algorithms to similar degree. In this simulation study based on monoenergetic and scatter-free projection data, we demonstrate that one of these factors is the extremely high number of iterations needed to remove artifacts that can appear around high-contrast structures. We also show (using the OSC method) that these artifacts can be adequately suppressed if statistical reconstruction is initialized with images generated by means of Radon inversion algorithms like filtered back projection (FBP). This allows the reconstruction time to be shortened by even as much as one order of magnitude. Although the initialization of the statistical algorithm with FBP image introduces some additional noise into the first iteration of OSC reconstruction, the resolution-noise trade-off and the contrast-to-noise ratio of final images are not markedly compromised

  1. Telehealth, Wearable Sensors, and the Internet: Will They Improve Stroke Outcomes Through Increased Intensity of Therapy, Motivation, and Adherence to Rehabilitation Programs?

    Science.gov (United States)

    Burridge, Jane H; Lee, Alan Chong W; Turk, Ruth; Stokes, Maria; Whitall, Jill; Vaidyanathan, Ravi; Clatworthy, Phil; Hughes, Ann-Marie; Meagher, Claire; Franco, Enrico; Yardley, Lucy

    2017-07-01

    Stroke, predominantly a condition of older age, is a major cause of acquired disability in the global population and puts an increasing burden on health care resources. Clear evidence for the importance of intensity of therapy in optimizing functional outcomes is found in animal models, supported by neuroimaging and behavioral research, and strengthened by recent meta-analyses from multiple clinical trials. However, providing intensive therapy using conventional treatment paradigms is expensive and sometimes not feasible because of social and environmental factors. This article addresses the need for cost-effective increased intensity of practice and suggests potential benefits of telehealth (TH) as an innovative model of care in physical therapy. We provide an overview of TH and present evidence that a web-supported program, used in conjunction with constraint-induced therapy (CIT), can increase intensity and adherence to a rehabilitation regimen. The design and feasibility testing of this web-based program, "LifeCIT," is presented. We describe how wearable sensors can monitor activity and provide feedback to patients and therapists. The methodology for the development of a wearable device with embedded inertial and mechanomyographic sensors, algorithms to classify functional movement, and a graphical user interface to present meaningful data to patients to support a home exercise program is explained. We propose that wearable sensor technologies and TH programs have the potential to provide most-effective, intensive, home-based stroke rehabilitation.

  2. The increase of metallothionein content in rat liver induced by x-ray irradiation and its physiological function

    International Nuclear Information System (INIS)

    Shiraishi, Noriyuki; Miyahara, Masanobu; Utsumi, Kozo; Aono, Kaname; Inoue, Bunji.

    1982-01-01

    Whether or not stress promotes peroxidase reaction of lipids in vivo influences the biosynthesis of metallothionein (MT) was studied. After X-ray irradiation rats were exposed to oxygen, and the liver supernatant was examined. The Zn distribution in the liver supernatant fraction of 10,000 in molecular weight, which was attributed to MT in origin, was small in the control group, but was great in the stress group. The amount of Cd found to the 10,000 fraction (Zn in MT is relatively easily replaced by Cd) was extremely smaller in the control group than in the stress group. These data indicate that the amount of Zn is small, with no appreciable presence of MT, in the 10,000 fraction of the control group. The X-ray irradiated group showed a marked increase of Zn 5 and 7 days later, indicating a definite increase of MT, and the group exposed to O 2 showed similar phenomena, suggesting induction of MT synthesis in the rat liver. (Chiba, N.)

  3. X-ray microscopy as an approach to increasing accuracy and efficiency of serial block-face imaging for correlated light and electron microscopy of biological specimens.

    Science.gov (United States)

    Bushong, Eric A; Johnson, Donald D; Kim, Keun-Young; Terada, Masako; Hatori, Megumi; Peltier, Steven T; Panda, Satchidananda; Merkle, Arno; Ellisman, Mark H

    2015-02-01

    The recently developed three-dimensional electron microscopic (EM) method of serial block-face scanning electron microscopy (SBEM) has rapidly established itself as a powerful imaging approach. Volume EM imaging with this scanning electron microscopy (SEM) method requires intense staining of biological specimens with heavy metals to allow sufficient back-scatter electron signal and also to render specimens sufficiently conductive to control charging artifacts. These more extreme heavy metal staining protocols render specimens light opaque and make it much more difficult to track and identify regions of interest (ROIs) for the SBEM imaging process than for a typical thin section transmission electron microscopy correlative light and electron microscopy study. We present a strategy employing X-ray microscopy (XRM) both for tracking ROIs and for increasing the efficiency of the workflow used for typical projects undertaken with SBEM. XRM was found to reveal an impressive level of detail in tissue heavily stained for SBEM imaging, allowing for the identification of tissue landmarks that can be subsequently used to guide data collection in the SEM. Furthermore, specific labeling of individual cells using diaminobenzidine is detectable in XRM volumes. We demonstrate that tungsten carbide particles or upconverting nanophosphor particles can be used as fiducial markers to further increase the precision and efficiency of SBEM imaging.

  4. Long-term association between the intensity of cosmic rays and mortality rates in the city of Sao Paulo

    Science.gov (United States)

    Vieira, C. L. Z.; Janot-Pacheco, E.; Lage, C.; Pacini, A.; Koutrakis, P.; Cury, P. R.; Shaodan, H.; Pereira, L. A.; Saldiva, P. H. N.

    2018-02-01

    Human beings are constantly exposed to many kinds of environmental agents which affect their health and lifespan. Galactic cosmic rays (GCRs) are the main source of ionizing radiation in the lower troposphere, in which secondary products can penetrate the ground and underground layers. GCRs affect the physical-chemical properties of the terrestrial atmosphere, as well as the biosphere. GCRs are modulated by solar activity and latitudinal geomagnetic field distribution. In our ecological/populational retrospective study, we analyzed the correlation between the annual flux of local secondary GCR-induced ionization (CRII) and mortality rates in the city of Sao Paulo, Brazil, between 1951-2012. The multivariate linear regression analyses adjusted by demographic and weather parameters showed that CRII are significantly correlated with total mortality, infectious disease mortality, maternal mortality, and perinatal mortality rates (p < 0.001). The underlying mechanisms are still unclear. Further cross-sectional and experimental cohort studies are necessary to understand the biophysical mechanisms of the association found here.

  5. Indirect radio-chemo-beta therapy: a targeted approach to increase biological efficiency of x-rays based on energy.

    Science.gov (United States)

    Oktaria, Sianne; Corde, Stéphanie; Lerch, Michael L F; Konstantinov, Konstantin; Rosenfeld, Anatoly B; Tehei, Moeava

    2015-10-21

    Despite the use of multimodal treatments incorporating surgery, chemotherapy and radiotherapy, local control of gliomas remains a major challenge. The potential of a new treatment approach called indirect radio-chemo-beta therapy using the synergy created by combining methotrexate (MTX) with bromodeoxyuridine (BrUdR) under optimum energy x-ray irradiation is assessed. 9L rat gliosarcoma cells pre-treated with 0.01 μM MTX and/or 10 μM BrUdR were irradiated in vitro with 50 kVp, 125 kVp, 250 kVp, 6 MV and 10 MV x-rays. The cytotoxicity was assessed using clonogenic survival as the radiobiological endpoint. The photon energy with maximum effect was determined using radiation sensitization enhancement factors at 10% clonogenic survival (SER10%). The cell cycle distribution was investigated using flow cytometric analysis with propidium iodide staining. Incorporation of BrUdR in the DNA was detected by the fluorescence of labelled anti-BrUdR antibodies. The radiation sensitization enhancement exhibits energy dependence with a maximum of 2.3 at 125 kVp for the combined drug treated cells. At this energy, the shape of the clonogenic survival curve of the pharmacological agents treated cells changes substantially. This change is interpreted as an increased lethality of the local radiation environment and is attributed to supplemented inhibition of DNA repair. Radiation induced chemo-beta therapy was demonstrated in vitro by the targeted activation of combined pharmacological agents with optimized energy tuning of x-ray beams on 9 L cells. Our results show that this is a highly effective form of chemo-radiation therapy.

  6. Adipositas ikke associeret med øget mortalitet ved kritisk sygdom og intensiv terapi [Obesity is not associated with an increased mortality in critical disease and intensive care.

    DEFF Research Database (Denmark)

    Toft, Palle; Lange, Britt

    2010-01-01

    The prevalence of obesity is increasing. The mortality and morbidity among obese intensive care unit (ICU) patients has been a matter of concern. Most of the retrospective studies performed have yielded contradictory results. Recently, two large prospective studies showed that respiratory failure......, length of mechanical ventilation and ICU acquired infections were increased in obese patients. Obesity was, however, not associated with increased mortality. The results were confirmed by a meta-analysis which showed that obesity was associated with increased morbidity but not with increased mortality...

  7. Exercise increases sphingoid base-1-phosphate levels in human blood and skeletal muscle in a time- and intensity-dependent manner

    DEFF Research Database (Denmark)

    Baranowski, Marcin; Błachnio-Zabielska, Agnieszka U; Charmas, Małgorzata

    2015-01-01

    PURPOSE: Sphingosine-1-phosphate (S1P) regulates cardiovascular function and plays an important role in muscle biology. We have previously reported that cycling exercise increased plasma S1P. Here, we investigated the effect of exercise duration and intensity on plasma and skeletal muscle S1P lev...

  8. Survey of doses and frequency of X-ray examinations on children at the intensive care unit of a large reference pediatric hospital

    International Nuclear Information System (INIS)

    Pedrosa de Azevedo, Ana Cecilia; Osibote, Adelaja Otolorin; Bastos Boechat, Marcia Cristina

    2006-01-01

    Objective: This work aims to evaluate the entrance surface dose (ESD), the body organ dose (BOD) and the effective dose (E) resulting from pediatric radiological procedures with the use of portable X-ray equipments. Materials and methods: The software DoseCal was used to evaluate the doses imparted to patients. The children were classified according to their weight and age groups, and the study included three sectors of the intensive care unit of a large reference pediatric hospital in Rio de Janeiro. Results: A total of 518 radiographs have been performed (424 for chest and 94 for abdomen). The statistical data were compared with previously published results. The BOD is presented for the most exposed organs. Conclusion: The mean value of ESD and E varied widely among neonates. The highest number of radiographs per infant peaked 33 for chest examination in the age group 0-1 year

  9. Nuclear Decay Data for the International Reactor Dosimetry Library for Fission and Fusion (IRDFF: Updated Evaluations of the Half-Lives and Gamma Ray Intensities

    Directory of Open Access Journals (Sweden)

    Chechev Valery P.

    2016-01-01

    Full Text Available Updated evaluations of the half-lives and prominent gamma ray intensities have been presented for 20 radionuclides – dosimetry reaction residuals. The new values of these decay characteristics recommended for the IRDFF library were obtained using the approaches and methodology adopted by the working group of the Decay Data Evaluation Project (DDEP cooperation. The experimental data published up to 2014 were taken into account in updated evaluations. The list of radionuclides includes 3H, 18F, 22Na, 24Na, 46Sc, 51Cr, 54Mn, 59Fe, 57Co, 60Co, 57Ni, 64Cu, 88Y, 132Te, 131I, 140Ba, 140La, 141Ce, 182Ta, 198Au.

  10. A theoretical study of the possibilities for localization of anomalous density distribution in rock by means of underground cosmic ray muon intensity measurements

    International Nuclear Information System (INIS)

    Jacobsson, L.; Joensson, G.; Kristiansson, K.; Malmqvist, L.

    1977-05-01

    The possibilities for in situ rock density determinations by means of sub-surface cosmic ray muon intensity measurements have been studied. The calculations are based on an hypothetical scintillation counter telescope intended for registration in a gallery. It is shown that fairly accurate density measurements are possible and that a certain spatial resolution can be achieved. The measurements are only influenced by the density distribution in the forward direction which can make the muon technique valuable in connection with gravity measurements. Different prospecting situations have been studied. It is found that in certain prospecting situations the accuracy needed for the indication of a massive ore body can be reached within an acceptable registration period. (Auth.)

  11. Circular intensity differential scattering (CIDS) measurements in the soft x-ray region of the spectrum (∼16 eV to 500 eV)

    International Nuclear Information System (INIS)

    Maestre, M.F.; Bustamante, C.; Snyder, P.; Rowe, E.; Hansen, R.

    1991-03-01

    We propose the use of recently developed techniques of circular intensity differential scattering (CIDS), as extended to the soft x-ray region of the spectrum (16 eV to 500 eV), to study the higher order organization of the eukaryotic chromosome. CIDS is the difference in scattering power of an object when illuminated by right circularly polarized vs. left circularly polarized electromagnetic radiation of arbitrary wavelength. CIDS has been shown to be a very sensitive measure of the helical organization of the scattering object eg. the eukaryotic chromosome. Preliminary results of measurements of samples of bacteriophages and octopus sperm done at SRC, Wisconsin, show the technique to be very sensitive to the dimensional parameters of the particles interrogated by circularly polarized light. 7 refs., 5 figs

  12. Experimental evidence and theoretical analysis of photoionized plasma under x-ray radiation produced by an intense laser

    International Nuclear Information System (INIS)

    Wang Feilu; Fujioka, Shinsuke; Nishimura, Hiroaki; Takabe, Hideaki; Kato, Daiji; Li Yutong; Zhao Gang; Zhang Jie

    2008-01-01

    Photoionized plasma was studied experimentally under laboratory conditions by means of high intensity short pulse lasers. The experiment consists of a gold cavity filled with nitrogen gas. Six laser beams were focused on the inner surface of the gold cavity, thereby generating an almost black-body radiation having temperature of 80 eV inside the cavity. This radiation heats the nitrogen gas mainly by means of photoionization. L-shell emissions from N V to N VII have been observed in the wavelength range between 90 and 200 A. A time-dependent Detailed Configuration Accounting computer program has been developed to analyze the experimental spectra. In contrast to standard analysis of astrophysical observations, the evidence for photoionization is inferred from the spectral lines ratios. Comparison between the experimental and simulated line spectra indicates that the radiation heated nitrogen attains temperature of 20-30 eV, much lower than the source radiation temperature. Paradoxically, it is also shown that similar line emissions can be reproduced computationally also when the radiation and plasma temperatures both equal approximately 60 eV. This misleading result indicates that experimental simulation in laboratory is sometimes necessary to avoid misinterpretation of astrophysical spectra.

  13. A signature of cosmic-ray increase in AD 774-775 from tree rings in Japan

    Science.gov (United States)

    Miyake, Fusa; Nagaya, Kentaro; Masuda, Kimiaki; Nakamura, Toshio

    2012-06-01

    Increases in 14C concentrations in tree rings could be attributed to cosmic-ray events, as have increases in 10Be and nitrate in ice cores. The record of the past 3,000 years in the IntCal09 data set, which is a time series at 5-year intervals describing the 14C content of trees over a period of approximately 10,000 years, shows three periods during which 14C increased at a rate greater than 3‰ over 10 years. Two of these periods have been measured at high time resolution, but neither showed increases on a timescale of about 1 year (refs 11 and 12). Here we report 14C measurements in annual rings of Japanese cedar trees from AD 750 to AD 820 (the remaining period), with 1- and 2-year resolution. We find a rapid increase of about 12‰ in the 14C content from AD 774 to 775, which is about 20 times larger than the change attributed to ordinary solar modulation. When averaged over 10 years, the data are consistent with the decadal IntCal 14C data from North American and European trees. We argue that neither a solar flare nor a local supernova is likely to have been responsible.

  14. Increased signal intensity within glioblastoma resection cavities on fluid-attenuated inversion recovery imaging to detect early progressive disease in patients receiving radiotherapy with concomitant temozolomide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Perry, Luke A. [Monash University, Melbourne (Australia); Korfiatis, Panagiotis; Erickson, Bradley J. [Mayo Clinic Rochester, Department of Radiology, Rochester, MN (United States); Agrawal, Jay P. [University of Massachusetts Medical School, Department of Radiology, Worcester, MA (United States)

    2018-01-15

    Our study tested the diagnostic accuracy of increased signal intensity (SI) within FLAIR MR images of resection cavities in differentiating early progressive disease (ePD) from pseudoprogression (PsP) in patients with glioblastoma treated with radiotherapy with concomitant temozolomide therapy. In this retrospective study approved by our Institutional Review Board, we evaluated the records of 122 consecutive patients with partially or totally resected glioblastoma. Region of interest (ROI) analysis assessed 33 MR examinations from 11 subjects with histologically confirmed ePD and 37 MR examinations from 14 subjects with PsP (5 histologically confirmed, 9 clinically diagnosed). After applying an N4 bias correction algorithm to remove B0 field distortion and to standardize image intensities and then normalizing the intensities based on an ROI of uninvolved white matter from the contralateral hemisphere, the mean intensities of the ROI from within the resection cavities were calculated. Measures of diagnostic performance were calculated from the receiver operating characteristic (ROC) curve using the threshold intensity that maximized differentiation. Subgroup analysis explored differences between the patients with biopsy-confirmed disease. At an optimal threshold intensity of 2.9, the area under the ROC curve (AUROC) for FLAIR to differentiate ePD from PsP was 0.79 (95% confidence interval 0.686-0.873) with a sensitivity of 0.818 and specificity of 0.694. The AUROC increased to 0.86 when only the patients with biopsy-confirmed PsP were considered. Increased SI within the resection cavity of FLAIR images is not a highly specific sign of ePD in glioblastoma patients treated with the Stupp protocol. (orig.)

  15. Alteration in cardiac uncoupling proteins and eNOS gene expression following high-intensity interval training in favor of increasing mechanical efficiency

    OpenAIRE

    Fallahi, Ali Asghar; Shekarfroush, Shahnaz; Rahimi, Mostafa; Jalali, Amirhossain; Khoshbaten, Ali

    2016-01-01

    Objective(s): High-intensity interval training (HIIT) increases energy expenditure and mechanical energy efficiency. Although both uncoupling proteins (UCPs) and endothelial nitric oxide synthase (eNOS) affect the mechanical efficiency and antioxidant capacity, their effects are inverse. The aim of this study was to determine whether the alterations of cardiac UCP2, UCP3, and eNOS mRNA expression following HIIT are in favor of increased mechanical efficiency or decreased oxidative stress. Mat...

  16. Repeated intravenous administration of gadobutrol does not lead to increased signal intensity on unenhanced T1-weighted images - a voxel-based whole brain analysis

    Energy Technology Data Exchange (ETDEWEB)

    Langner, Soenke; Kromrey, Marie-Luise [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); Kuehn, Jens-Peter [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); University Hospital, Carl Gustav Carus University Dresden, Institute for Radiology, Dresden (Germany); Grothe, Matthias [University Medicine Greifswald, Department of Neurology, Greifswald (Germany); Domin, Martin [University Medicine Greifswald, Functional Imaging Unit, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany)

    2017-09-15

    To identify a possible association between repeated intravenous administration of gadobutrol and increased signal intensity in the grey and white matter using voxel-based whole-brain analysis. In this retrospective single-centre study, 217 patients with a clinically isolated syndrome underwent baseline brain magnetic resonance imaging and at least one annual follow-up examination with intravenous administration of 0.1 mmol/kg body weight of gadobutrol. Using the ''Diffeomorphic Anatomical Registration using Exponentiated Lie algebra'' (DARTEL) normalisation process, tissue templates for grey matter (GM), white matter (WM), and cerebrospinal fluid (CSF) were calculated, as were GM-CSF and WM-CSF ratios. Voxel-based whole-brain analysis was used to calculate the signal intensity for each voxel in each data set. Paired t-test was applied to test differences to baseline MRI for significance. Voxel-based whole-brain analysis demonstrated no significant changes in signal intensity of grey and white matter after up to five gadobutrol administrations. There was no significant change in GM-CSF and grey WM-CSF ratios. Voxel-based whole-brain analysis did not demonstrate increased signal intensity of GM and WM on unenhanced T1-weighted images after repeated gadobutrol administration. The molecular structure of gadolinium-based contrast agent preparations may be an essential factor causing SI increase on unenhanced T1-weighted images. (orig.)

  17. Few-photon electron-positron pair creation in the collision of a relativistic nucleus and an intense x-ray laser beam

    International Nuclear Information System (INIS)

    Mueller, C.; Gruen, N.; Voitkiv, A.B.

    2004-01-01

    We study the nonlinear process of e - e + pair creation by a nucleus which moves at a relativistic energy in the laboratory frame and collides with an intense x-ray laser beam. The collision system under consideration is chosen in such a way that the simultaneous absorption of at least two photons from the laser wave is required in order to exceed the energy threshold of the reaction. We calculate total and differential rates for both free-free and bound-free pair production. In the case of free-free pair creation we demonstrate the effect of the laser polarization on the spectra of the produced particles, and we show that at very high intensities the total rate exhibits features analogous to those well known from above-threshold ionization rates for atoms. In the case of bound-free pair creation a singularity is found in the laboratory frame angular distribution of the produced positron. This singularity represents a distinct characteristic of the bound-free pair production and allows one to separate this process from free-free pair creation even without detecting a bound state of the captured electron. For both types of pair creation we consider the dependences of the total rates on the collision parameters, give the corresponding scaling laws, and discuss the possibility to observe these nonlinear processes in a future experiment

  18. Climate-change driven increase in high intensity rainfall events: Analysis of development in the last decades and towards an extrapolation of future progression

    Science.gov (United States)

    Müller, Eva; Pfister, Angela; Gerd, Büger; Maik, Heistermann; Bronstert, Axel

    2015-04-01

    Hydrological extreme events can be triggered by rainfall on different spatiotemporal scales: river floods are typically caused by event durations of between hours and days, while urban flash floods as well as soil erosion or contaminant transport rather result from storms events of very short duration (minutes). Still, the analysis of climate change impacts on rainfall-induced extreme events is usually carried out using daily precipitation data at best. Trend analyses of extreme rainfall at sub-daily or even sub-hourly time scales are rare. In this contribution two lines of research are combined: first, we analyse sub-hourly rainfall data for several decades in three European regions.Second, we investigate the scaling behaviour of heavy short-term precipitation with temperature, i.e. the dependence of high intensity rainfall on the atmospheric temperature at that particular time and location. The trend analysis of high-resolution rainfall data shows for the first time that the frequency of short and intensive storm events in the temperate lowland regions in Germany has increased by up to 0.5 events per year over the last decades. I.e. this trend suggests that the occurrence of these types of storms have multiplied over only a few decades. Parallel to the changes in the rainfall regime, increases in the annual and seasonal average temperature and changes in the occurrence of circulation patterns responsible for the generation of high-intensity storms have been found. The analysis of temporally highly resolved rainfall records from three European regions further indicates that extreme precipitation events are more intense with warmer temperatures during the rainfall event. These observations follow partly the Clausius-Clapeyron relation. Based on this relation one may derive a general rule of maximum rainfall intensity associated to the event temperature, roughly following the Clausius-Clapeyron (CC) relation. This rule might be used for scenarios of future maximum

  19. Low-intensity repetitive magnetic stimulation lowers action potential threshold and increases spike firing in layer 5 pyramidal neurons in vitro.

    Science.gov (United States)

    Tang, Alexander D; Hong, Ivan; Boddington, Laura J; Garrett, Andrew R; Etherington, Sarah; Reynolds, John N J; Rodger, Jennifer

    2016-10-29

    Repetitive transcranial magnetic stimulation (rTMS) has become a popular method of modulating neural plasticity in humans. Clinically, rTMS is delivered at high intensities to modulate neuronal excitability. While the high-intensity magnetic field can be targeted to stimulate specific cortical regions, areas adjacent to the targeted area receive stimulation at a lower intensity and may contribute to the overall plasticity induced by rTMS. We have previously shown that low-intensity rTMS induces molecular and structural plasticity in vivo, but the effects on membrane properties and neural excitability have not been investigated. Here we investigated the acute effect of low-intensity repetitive magnetic stimulation (LI-rMS) on neuronal excitability and potential changes on the passive and active electrophysiological properties of layer 5 pyramidal neurons in vitro. Whole-cell current clamp recordings were made at baseline prior to subthreshold LI-rMS (600 pulses of iTBS, n=9 cells from 7 animals) or sham (n=10 cells from 9 animals), immediately after stimulation, as well as 10 and 20min post-stimulation. Our results show that LI-rMS does not alter passive membrane properties (resting membrane potential and input resistance) but hyperpolarises action potential threshold and increases evoked spike-firing frequency. Increases in spike firing frequency were present throughout the 20min post-stimulation whereas action potential (AP) threshold hyperpolarization was present immediately after stimulation and at 20min post-stimulation. These results provide evidence that LI-rMS alters neuronal excitability of excitatory neurons. We suggest that regions outside the targeted region of high-intensity rTMS are susceptible to neuromodulation and may contribute to rTMS-induced plasticity. Copyright © 2016 IBRO. All rights reserved.

  20. Estimated Cost-Effectiveness of Intensive Interdisciplinary Behavioral Treatment for Increasing Oral Intake in Children With Feeding Difficulties.

    Science.gov (United States)

    Dempster, Robert; Burdo-Hartman, Wendelin; Halpin, Elizabeth; Williams, Carol

    2016-09-01

    OBJECTIVE : To examine the cost-effectiveness of intensive interdisciplinary behavioral treatment (IIBT) to address severe pediatric feeding difficulties and lead to the removal or prevention of gastrostomy tubes (G tubes) from the perspective of the insurance company.  METHODS : Costs associated with G tubes and IIBT were compiled from the available literature and national databases. Costs were updated to price at the start of 2015 to allow data from different years to be analyzed on the same scale.  RESULTS : One-way sensitivity and two-way threshold analyses demonstrated that IIBT may be a cost-effective treatment for prevention and removal of G tubes over 5 and 10 years.  DISCUSSION : Data from this study can be used to justify cost of services for IIBT, and programs can use these data to discuss conservative savings of IIBT based on their treatment model and level of effectiveness. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Is There Evidence That Active Videogames Increase Energy Expenditure and Exercise Intensity for People Poststroke and with Cerebral Palsy?

    Science.gov (United States)

    Deutsch, Judith E; Guarrera-Bowlby, Phyllis; Myslinski, Mary Jane; Kafri, Michal

    2015-02-01

    This article asked and answered the question of whether there was evidence to support the use of videogames for promotion of wellness and fitness for people poststroke and those with cerebral palsy (CP). A literature search of PubMed, CINAHL, and PEDro using a population, intervention, and outcome (PIO) approach and the key words "stroke (or CP) AND video games (and synonyms) AND energy expenditure (EE) (and synonyms)" was conducted. It yielded two relevant references for people poststroke and five references for people with CP. The literature extraction and synthesis by the categories of the PIO indicated that most studies used only the population of interest, except two that compared the EE with that of healthy controls. The main finding is that both people poststroke (moderate severity) and people with CP (mild severity) can achieve moderate EE playing Wii(™) (Nintendo, Kyoto, Japan), PlayStation(®) (Sony, Tokyo, Japan), and Kinect(™) (Microsoft, Redmond, WA) games. Adults with CP of mild severity played the videogames at vigorous levels, whereas those with severe CP played them at low levels. There appears to be an interaction between development and severity that influences the exercise intensity measured by EE. The findings suggests that videogames are a gateway for wellness promotion.

  2. New determinations of gamma-ray line intensities of the E{sub p}=550 and 1747 keV resonances of the {sup 13}C(p,{gamma}){sup 14}N reaction

    Energy Technology Data Exchange (ETDEWEB)

    Kiener, J. E-mail: kiener@csnsm.in2p3.fr; Gros, M.; Tatischeff, V.; Attie, D.; Bailly, I.; Bauchet, A.; Chapuis, C.; Cordier, B.; Deloncle, I.; Porquet, M.G.; Schanne, S.; Sereville, N. de; Tauzin, G

    2004-03-01

    Gamma-ray angular distributions for the resonances at E{sub p}=550 and 1747 keV of the radiative capture reaction {sup 13}C(p,{gamma}){sup 14}N have been measured, using intense proton beams on isotopically pure {sup 13}C targets. Experimental gamma-ray spectra were obtained with three HP-Germanium detectors at four angles for E{sub p}=550 keV and six angles for E{sub p}=1747 keV in the range of 0-90 deg. with respect to the proton beam. From the data, relative intensities for the strongest transitions were extracted with an accuracy of typically 5%, making these resonances new useful gamma-ray standards for efficiency calibration in the energy range from E{sub {gamma}}=1.6-9 MeV. Gamma-ray branching ratios were obtained for several levels of {sup 14}N and are compared with literature values.

  3. Acute growth hormone administration causes exaggerated increases in plasma lactate and glycerol during moderate to high intensity bicycling in trained young men

    DEFF Research Database (Denmark)

    Lange, K.H.; Larsson, B.; Flyvbjerg, A.

    2002-01-01

    ). In the placebo trial, all subjects completed the exercise protocol without any difficulties. In contrast, two subjects were not able to complete the exercise protocol in the GH trial, and one subject barely managed to complete the protocol. In addition, GH administration resulted in exaggerated increases...... in increased whole body fat oxidation (indirect calorimetry). Plasma glucose was, on average, 9% higher during exercise after GH administration compared with placebo (P ... during 90 min of subsequent bicycling at moderate to high intensity. The exaggerated increase in plasma lactate may be associated with substantially decreased exercise performance....

  4. Improved brachial artery shear patterns and increased flow-mediated dilation after low-volume high-intensity interval training in type 2 diabetes.

    Science.gov (United States)

    Ghardashi Afousi, Alireza; Izadi, Mohammad Reza; Rakhshan, Kamran; Mafi, Farnoosh; Biglari, Soheil; Gandomkar Bagheri, Habibalah

    2018-06-22

    What is the central question of this study? Endothelial function is impaired because of increased oscillatory and retrograde shear in patients with type 2 diabetes. It is unclear whether low-volume high-intensity interval training and continuous moderate intensity exercise can modulate oscillatory and retrograde shear, blood flow and flow-mediated arterial dilation in these patients. What is the main finding and its importance? We found that low-volume high-intensity interval training, by increasing anterograde shear and decreasing retrograde shear and oscillatory index, can increase nitric oxide production and consequently result in increased flow-mediated dilation and outward arterial remodelling in patients with type 2 diabetes. Atherosclerosis in patients with type 2 diabetes is characterized by endothelial dysfunction associated with impaired flow-mediated dilation (FMD) and increases retrograde and oscillatory shear. The present study investigated endothelium-dependent vasodilation and shear rate in patients with type 2 diabetes at baseline and follow-up after 12 weeks of low-volume high-intensity interval training (LV-HIIT) or continuous moderate intensity training (CMIT). Seventy five sedentary patients with type 2 diabetes and untreated pre- or stage I hypertension were randomly divided into LV-HIIT, CMIT and control groups. The LV-HIIT group intervention was 12 intervals of 1.5 min at 85%-90% HR max and 2 min at 55%-60% HR max . The CMIT group intervention was 42 min of exercise at 70% HR max for 3 sessions per week during 12 weeks. High-resolution Doppler ultrasound was used to measure FMD, arterial diameter, anterograde and retrograde blood flow and shear rate patterns. Brachial artery FMD increased significantly in the LV-HIIT group (3.83 ± 1.13 baseline, 7.39 ± 3.6% follow-up), whereas there were no significant increase in the CMIT group (3.45 ± 0.97 baseline, 4.81 ± 2.36% follow-up) compared to the control group (3.16 ± 0

  5. Evidence of Increased Antibiotic Resistance in Phylogenetically-Diverse Aeromonas Isolates from Semi-Intensive Fish Ponds Treated with Antibiotics.

    Science.gov (United States)

    Patil, Hemant J; Benet-Perelberg, Ayana; Naor, Alon; Smirnov, Margarita; Ofek, Tamir; Nasser, Ahmed; Minz, Dror; Cytryn, Eddie

    2016-01-01

    The genus Aeromonas is ubiquitous in aquatic environments encompassing a broad range of fish and human pathogens. Aeromonas strains are known for their enhanced capacity to acquire and exchange antibiotic resistance genes and therefore, are frequently targeted as indicator bacteria for monitoring antimicrobial resistance in aquatic environments. This study evaluated temporal trends in Aeromonas diversity and antibiotic resistance in two adjacent semi-intensive aquaculture facilities to ascertain the effects of antibiotic treatment on antimicrobial resistance. In the first facility, sulfadiazine-trimethoprim was added prophylactically to fingerling stocks and water column-associated Aeromonas were monitored periodically over an 11-month fish fattening cycle to assess temporal dynamics in taxonomy and antibiotic resistance. In the second facility, Aeromonas were isolated from fish skin ulcers sampled over a 3-year period and from pond water samples to assess associations between pathogenic strains to those in the water column. A total of 1200 Aeromonas isolates were initially screened for sulfadiazine resistance and further screened against five additional antimicrobials. In both facilities, strong correlations were observed between sulfadiazine resistance and trimethoprim and tetracycline resistances, whereas correlations between sulfadiazine resistance and ceftriaxone, gentamicin, and chloramphenicol resistances were low. Multidrug resistant strains as well as sul1, tetA , and intI1 gene-harboring strains were significantly higher in profiles sampled during the fish cycle than those isolated prior to stocking and these genes were extremely abundant in the pathogenic strains. Five phylogenetically distinct Aeromonas clusters were identified using partial rpoD gene sequence analysis. Interestingly, prior to fingerling stocking the diversity of water column strains was high, and representatives from all five clusters were identified, including an A. salmonicida

  6. Evidence of increased antibiotic resistance in phylogenetically-diverse Aeromonas isolates from semi-intensive fish ponds treated with antibiotics

    Directory of Open Access Journals (Sweden)

    Hemant J Patil

    2016-11-01

    Full Text Available The genus Aeromonas is ubiquitous in aquatic environments encompassing a broad range of fish and human pathogens. Aeromonas strains are known for their enhanced capacity to acquire and exchange antibiotic resistance genes and therefore, are frequently targeted as indicator bacteria for monitoring antimicrobial resistance in aquatic environments. This study evaluated temporal trends in Aeromonas diversity and antibiotic resistance in two adjacent semi-intensive aquaculture facilities to ascertain effects of antibiotic treatment on antimicrobial resistance. In the first facility, sulfadiazine-trimethoprim was added prophylactically upon fingerling stocking and water column-associated Aeromonas were monitored periodically over an eleven-month fish-fattening cycle to assess temporal dynamics in taxonomy and antibiotic resistance. In the second facility, Aeromonas were isolated from fish skin ulcers sampled over a three-year period and from pond water samples to assess associations between pathogenic strains to those in the water column. A total of 1200 Aeromonas spp. were isolated, initially screened for sulfadiazine resistance and further screened against five additional antibiotics. In both facilities, strong correlations were observed between sulfadiazine resistance and trimethoprim and tetracycline resistances, whereas correlations between sulfadiazine resistance and ceftriaxone, gentamycin and chloramphenicol resistances were low. Abundance of multi-drug resistant strains as well as sul1, tetA and intI1 gene-harboring strains was significantly higher in profiles sampled during the fish cycle than those isolated prior to stocking and these genes were extremely abundant in the pathogenic strains. Five phylogenetically-distinct Aeromonas clusters were revealed using partial rpoD gene sequence analysis. Interestingly, prior to fingerling stocking the diversity of water column strains was high, and representatives from all five clusters were

  7. A holistic life cycle analysis of waste management scenarios at increasing source segregation intensity: the case of an Italian urban area.

    Science.gov (United States)

    Di Maria, Francesco; Micale, Caterina

    2014-11-01

    Life cycle analysis of several waste management scenarios for an Italian urban area was performed on the basis of different source segregation collection (SS) intensities from 0% up to 52%. Source segregated waste was recycled and or/recovered by composting. Residual waste management options were by landfilling, incineration with energy recovery or solid recovered fuel (SRF) production to substitute for coal. The increase in fuel and materials consumption due to increase in SS had negligible influence on the environmental impact of the system. Recycling operations such as incineration and SRF were always advantageous for impact reduction. There was lower impact for an SS of 52% even though the difference with the SS intensity of 35% was quite limited, about 15%. In all the configurations analyzed, the best environmental performance was achieved for the management system producing SRF by the biodrying process. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Characteristics of x-ray radiation from a gas-puff z-pinch plasma

    International Nuclear Information System (INIS)

    Akiyama, N.; Takasugi, K.

    2002-01-01

    Characteristics of x-ray radiation from Ar gas-puff z-pinch plasma have been investigated by changing delay time of discharge from gas puffing. Intense cloud structure of x-ray image was observed at small delay time region, but the total x-ray signal was not so intense. The x-ray signal increased with increasing the delay time, and hot spots of x-ray image also became intense. Electron temperature was evaluated from x-ray spectroscopic data, and no significant difference in temperature was observed. (author)

  9. Increased signal intensities in the dentate nucleus and globus pallidus on unenhanced T1-weighted images: evidence in children undergoing multiple gadolinium MRI exams

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Houchun H.; Pokorney, Amber; Towbin, Richard B.; Miller, Jeffrey H. [Phoenix Children' s Hospital, Department of Medical Imaging and Radiology, Phoenix, AZ (United States)

    2016-10-15

    Recent reports have suggested residual gadolinium deposition in the brain in subjects undergoing multiple contrast-enhanced MRI exams. These findings have raised some concerns regarding gadolinium-based contrast agent (GBCA) usage and retention in brain tissues. To summarize findings of hyperintense brain structures on precontrast T1-weighted images in 21 children undergoing multiple GBCA MRI exams. This retrospective study involved 21 patients, each of whom received multiple MRI examinations (range: 5-37 exams) with GBCA over the course of their medical treatment (duration from first to most recent exam: 1.2-12.9 years). The patients were between 0.9 and 14.4 years of age at the time of their first GBCA exam. Regions of interest were drawn in the dentate nucleus and the globus pallidus on 2-D fast spin echo images acquired at 1.5 T. The signal intensities of these two structures were normalized by that of the corpus callosum genu. Signal intensity ratios from these patients were compared to control patients of similar ages who have never received GBCA. Signal intensity ratios increased between the first and the most recent MRI exam in all 21 patients receiving GBCA, with an increase of 18.6%±12.7% (range: 0.5% to 47.5%) for the dentate nucleus and 12.4%±7.4% (range: -1.2% to 33.7%) for the globus pallidus (P<0.0001). Signal intensity ratios were also higher in GBCA patients than in controls (P<0.01). The degree of signal intensity enhancement did not correlate with statistical significance to the cumulative number or volume of GBCA administrations each patient received, the patient's age or the elapsed time between the first and most recent GBCA MRI exams. These results in children are consistent with recent findings in adults, suggesting possible gadolinium deposition in the brain. (orig.)

  10. The ability of non-computer tasks to increase biomechanical exposure variability in computer-intensive office work.

    Science.gov (United States)

    Barbieri, Dechristian França; Srinivasan, Divya; Mathiassen, Svend Erik; Nogueira, Helen Cristina; Oliveira, Ana Beatriz

    2015-01-01

    Postures and muscle activity in the upper body were recorded from 50 academics office workers during 2 hours of normal work, categorised by observation into computer work (CW) and three non-computer (NC) tasks (NC seated work, NC standing/walking work and breaks). NC tasks differed significantly in exposures from CW, with standing/walking NC tasks representing the largest contrasts for most of the exposure variables. For the majority of workers, exposure variability was larger in their present job than in CW alone, as measured by the job variance ratio (JVR), i.e. the ratio between min-min variabilities in the job and in CW. Calculations of JVRs for simulated jobs containing different proportions of CW showed that variability could, indeed, be increased by redistributing available tasks, but that substantial increases could only be achieved by introducing more vigorous tasks in the job, in casu illustrated by cleaning.

  11. High intensity interior aircraft noise increases the risk of high diastolic blood pressure in Indonesian Air Force pilots

    Directory of Open Access Journals (Sweden)

    Minarma Siagian

    2009-12-01

    Full Text Available Aim: To analyze the effects of aircraft noise, resting pulse rate, and other factors on the risk of high diastolic blood pressure (DBP in Indonesian Air Force pilots.Methods: A nested case-control study was conducted using data extracted from annual medical check-ups indoctrination aerophysiologic training records at the Saryanto Aviation and Aerospace Health Institute (LAKESPRA in Jakarta from January 2003 – September 2008. For analysis of DBP: the case group with DBP ≥ 90 mmHg were compared with contral group with DBP < 79 mmHG. One case matched to 12 controls.Results: Out of 567 pilots, 544 (95.9% had complete medical records. For this analysis there were 40 cases of high DBP and 480 controls for DBP. Pilots exposed to aircraft noise 90-95 dB rather than 70-80 dB had a 2.7-fold increase for high DBP [adjusted odds ratio (ORa = 2.70; 95% confi dence interval (CI = 1.05-6.97]. Pilots with resting pulse rates of ≥ 81/minute rather than ≤ 80/minute had a 2.7-fold increase for high DBP (ORa = 2.66; 95% CI = 1.26-5.61. In terms of total fl ight hours, pilots who had 1401-11125 hours rather than 147-1400 hours had a 3.2-fold increase for high DBP (ORa = 3.18; 95% CI = 1.01-10.03.Conclusion: High interior aircraft noise, high total flight hours,  and high resting pulse rate, increased risk for high DBP. Self assessment of resting pulse rate can be used to control the risk of high DBP. (Med J Indones 2009; 276: 276-82Keywords: diastolic blood pressure, aircraft noise, resting pulse rate, military pilots

  12. An intervention to reduce sitting and increase light-intensity physical activity at work: Design and rationale of the 'Stand & Move at Work' group randomized trial.

    Science.gov (United States)

    Buman, Matthew P; Mullane, Sarah L; Toledo, Meynard J; Rydell, Sarah A; Gaesser, Glenn A; Crespo, Noe C; Hannan, Peter; Feltes, Linda; Vuong, Brenna; Pereira, Mark A

    2017-02-01

    American workers spend 70-80% of their time at work being sedentary. Traditional approaches to increase moderate-vigorous physical activity (MVPA) may be perceived to be harmful to productivity. Approaches that target reductions in sedentary behavior and/or increases in standing or light-intensity physical activity [LPA] may not interfere with productivity and may be more feasible to achieve through small changes accumulated throughout the workday METHODS/DESIGN: This group randomized trial (i.e., cluster randomized trial) will test the relative efficacy of two sedentary behavior focused interventions in 24 worksites across two states (N=720 workers). The MOVE+ intervention is a multilevel individual, social, environmental, and organizational intervention targeting increases in light-intensity physical activity in the workplace. The STAND+ intervention is the MOVE+ intervention with the addition of the installation and use of sit-stand workstations to reduce sedentary behavior and enhance light-intensity physical activity opportunities. Our primary outcome will be objectively-measured changes in sedentary behavior and light-intensity physical activity over 12months, with additional process measures at 3months and longer-term sustainability outcomes at 24months. Our secondary outcomes will be a clustered cardiometabolic risk score (comprised of fasting glucose, insulin, triglycerides, HDL-cholesterol, and blood pressure), workplace productivity, and job satisfaction DISCUSSION: This study will determine the efficacy of a multi-level workplace intervention (including the use of a sit-stand workstation) to reduce sedentary behavior and increase LPA and concomitant impact on cardiometabolic health, workplace productivity, and satisfaction. ClinicalTrials.gov Identifier: NCT02566317 (date of registration: 10/1/2015). Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Relaxed damage threshold intensity conditions and nonlinear increase in the conversion efficiency of an optical parametric oscillator using a bi-directional pump geometry.

    Science.gov (United States)

    Norris, G; McConnell, G

    2010-03-01

    A novel bi-directional pump geometry that nonlinearly increases the nonlinear optical conversion efficiency of a synchronously pumped optical parametric oscillator (OPO) is reported. This bi-directional pumping method synchronizes the circulating signal pulse with two counter-propagating pump pulses within a linear OPO resonator. Through this pump scheme, an increase in nonlinear optical conversion efficiency of 22% was achieved at the signal wavelength, corresponding to a 95% overall increase in average power. Given an almost unchanged measured pulse duration of 260 fs under optimal performance conditions, this related to a signal wavelength peak power output of 18.8 kW, compared with 10 kW using the traditional single-pass geometry. In this study, a total effective peak intensity pump-field of 7.11 GW/cm(2) (corresponding to 3.55 GW/cm(2) from each pump beam) was applied to a 3 mm long periodically poled lithium niobate crystal, which had a damage threshold intensity of 4 GW/cm(2), without impairing crystal integrity. We therefore prove the application of this novel pump geometry provides opportunities for power-scaling of synchronously pumped OPO systems together with enhanced nonlinear conversion efficiency through relaxed damage threshold intensity conditions.

  14. Use of high-intensity sonication for pre-treatment of biological tissues prior to multielemental analysis by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    De La Calle, Inmaculada; Costas, Marta; Cabaleiro, Noelia; Lavilla, Isela; Bendicho, Carlos

    2012-01-01

    In this work, two ultrasound-based procedures are developed for sample preparation prior to determination of P, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se and Sr in biological tissues by total reflection X-ray fluorescence spectrometry. Ultrasound-assisted extraction by means of a cup-horn sonoreactor and ultrasonic-probe slurry sampling were compared with a well-established procedure such as magnetic agitation slurry sampling. For that purpose, seven certified reference materials and different real samples of animal tissue were used. Similar accuracy and precision is obtained with the three sample preparation approaches tried. Limits of detection were dependent on both the sample matrix and the sample pre-treatment used, best values being achieved with ultrasound-assisted extraction. Advantages of ultrasound-assisted extraction include reduced sample handling, decreased contamination risks (neither addition of surfactants nor use of foreign objects inside the extraction vial), simpler background (no solid particles onto the sample carrier) and improved recovery for some elements such as P. A mixture of 10% v/v HNO 3 + 20–40% v/v HCl was suitable for extraction from biological tissues. - Highlights: ► We implement high-intensity sonication for pre-treatment of biological tissues. ► Multielemental analysis is performed by total reflection X-ray spectrometry. ► Ultrasound-based procedures are developed and compared to conventional slurry preparation. ► Features such as background, recovery and sample handling are favored by using ultrasonic extraction.

  15. The response of a simulated mesoscale convective system to increased aerosol pollution: Part I: Precipitation intensity, distribution, and efficiency

    Science.gov (United States)

    Clavner, Michal; Cotton, William R.; van den Heever, Susan C.; Saleeby, Stephen M.; Pierce, Jeffery R.

    2018-01-01

    Mesoscale Convective Systems (MCSs) are important contributors to rainfall in the High Plains of the United States and elsewhere in the world. It is therefore of interest to understand how different aerosols serving as cloud condensation nuclei (CCN) may impact the total amount, rates and spatial distribution of precipitation produced by MCSs. In this study, different aerosol concentrations and their effects on precipitation produced by an MCS are examined by simulating the 8 May 2009 "Super-Derecho" MCS using the Regional Atmospheric Modeling System (RAMS), a cloud-resolving model (CRM) with sophisticated aerosol and microphysical parameterizations. Three simulations were conducted that differed only in the initial concentration, spatial distribution, and chemical composition of aerosols. Aerosol fields were derived from the output of GEOS-Chem, a 3D chemical transport numerical model. Results from the RAMS simulations show that the total domain precipitation was not significantly affected by variations in aerosol concentrations, however, the pollution aerosols altered the precipitation characteristics. The more polluted simulations exhibited higher precipitation rates, higher bulk precipitation efficiency, a larger area with heavier precipitation, and a smaller area with lighter precipitation. These differences arose as a result of aerosols enhancing precipitation in the convective region of the MCS while suppressing precipitation from the MCS's stratiform-anvil. In the convective region, several processes likely contributed to an increase of precipitation. First, owing to the very humid environment of this storm, the enhanced amount of cloud water available to be collected overwhelmed the reduction in precipitation efficiency associated with the aerosol-induced production of smaller droplets which led to a net increase in the conversion of cloud droplets to precipitation. Second, higher aerosol concentrations led to invigoration of convective updrafts which

  16. The determination of crystal size and disorder from the X-ray diffraction photograph of polymer fibres. 2. Modelling intensity profiles

    International Nuclear Information System (INIS)

    Hall, I.H.; Somashekar, R.

    1991-01-01

    The intensity profile of the X-ray reflection from a crystalline material is related to the lattice disorder and the distribution of crystal sizes through its Fourier cosine coefficients. However, existing methods of obtaining these structural parameters from the coefficients require more than one order of reflection and this is seldom available with polymer fibres. They also rely heavily on the low-order harmonics which are those determined with least accuracy. The development and testing of a method which overcomes this weakness and which is suitable for use with a single order is described. The coefficients are calculated for a model with paracrystalline disorder and an assumed distribution of crystal sizes and the parameters describing this model are refined to minimize the discrepancy between the calculated and experimental values of the coefficients. Provided the distribution of lengths is asymmetric this discrepancy is no greater than would be expected from experimental error and so the assumed model cannot be rejected on the evidence available. Since a range of model parameters all gave equally good agreement with experiment, it was not possible with a single order to obtain a well defined set of values. Diffraction patterns displaying two orders had been chosen and results from the second order were consistent with the first, only a narrow range satisfying both simultaneously. The method was further developed by calculating the intensity profile from the harmonics and using this in the refinement. There was no advantage over using harmonics; indeed, on occasions the refinement algorithm was unstable producing unreliable results. (orig.)

  17. Yaku-cedar tells cosmic outbursts in ancient times. Anomalies of cosmic ray intensity in AD 774-775 and AD 993-994

    International Nuclear Information System (INIS)

    Miyake, Fusa; Masuda, Kimiaki

    2014-01-01

    Measurements of cosmogenic nuclides, which are radioisotopes produced by cosmic rays in the atmosphere, provide important information regarding extraterrestrial high-energy events. We present 14 C measurements in annual rings of Japanese cedar trees with 1- and 2-year resolutions, and a finding of two sudden increases of 14 C content by significant amount from AD 774 to 775 and AD 993 to 994. The short-term increases of radioactive nuclide production were also found in tree rings of Europe and Antarctic ice core. This strongly indicates that the anomalies were not due to local terrestrial events, but triggered by cosmic outbursts that affected the whole planet. Several conjectures have been made upon the origin of the events, e.g. nearby supernovae (∼200 pc), Galactic short gamma-ray bursts, and violent solar mass ejections like SPEs (solar proton events) or super flares. We investigated energetics and the frequencies of occurrence of the phenomena, and demonstrate that SPE is likely to be the origin of the two 14 C increase events. Astrophysical significances and impact to modern human society are also discussed. (author)

  18. Bell's palsy: what is the prognostic value of measurements of signal intensity increases with contrast enhancement on MRI?

    International Nuclear Information System (INIS)

    Kress, B.P.J.; Efinger, K.; Solbach, T.; Gottschalk, A.; Baehren, W.; Griesbeck, F.; Kornhuber, A.W.

    2002-01-01

    Our objective was to assess the prognostic value of measurements of the degree of contrast enhancement of the intratemporal segments of the facial nerve. We prospectively obtained MRI, slice thickness <1 mm of 20 patients with a facial palsy on the first day of inpatient treatment, and measured contrast enhancement of the nerve. The data were compared with compound muscle action potential (CMAP) measurements and the clinical course. Analysis of the initial enabled differentiation of three patients whose palsy was to show no improvement from 17 whose palsy was to resolve as expected. No patient with a poor outcome showed lesser increase in signal in the internal auditory canal, pars tympanica and pars mastoidea than patients who fully recovered. In no patient who had been diagnosed on the basis of the initial MRI as having a ''normal'' palsy was the amplitude of the (CMAP) reduced to less than 20% that of the normal side. Measurement of contrast enhancement was thus shown to be a prognostic indicator and may provide a basis for a differential treatment of facial palsy. (orig.)

  19. Dissimilarity of Ant Communities Increases with Precipitation, but not Reduced Land-Use Intensity, in Indonesian Cacao Agroforestry

    Directory of Open Access Journals (Sweden)

    Damayanti Buchori

    2013-01-01

    Full Text Available Land-use degradation and climate change are well-known drivers of biodiversity loss, but little information is available about their potential interaction. Here, we focus on the effects of land-use and precipitation on ant diversity in cacao agroforestry. In Central Sulawesi, Indonesia, we selected 16 cacao agroforestry plots with a shaded vs. unshaded plot in each of eight villages differing in precipitation (1032–2051 mm annual rainfall. On each plot, 10 cacao trees with similar size and age (7–10 years were selected for hand collection of ants on each cacao tree and the soil surface. In total, we found 80 ant species belonging to five subfamilies. Land-use intensification (removal of shade trees and precipitation had no effect on species richness of ants per cacao tree (alpha diversity and, in an additive partitioning approach, within-plot beta diversity. However, higher precipitation (but not shade significantly increased ant species dissimilarity across cacao trees within a plot, with ant species showing contrasting responses to precipitation. Reduced precipitation causing drought stress appeared to contribute to convergence of ant community structure, presumably via reduced heterogeneity in cacao tree growth. In conclusion, reduced precipitation greatly influenced ant community dissimilarity and appeared to be more important for ant community structure than land-use intensification.

  20. High-intensity stress elicits robust cortisol increases, and impairs working memory and visuo-spatial declarative memory in Special Forces candidates: A field experiment.

    Science.gov (United States)

    Taverniers, John; Van Ruysseveldt, Joris; Smeets, Tom; von Grumbkow, Jasper

    2010-07-01

    While running a selection procedure, 27 male Belgian Special Forces candidates, with a mean age of 27.4 years (SD = 5.1), were randomly assigned to a no-stress control (n = 14) or a high-intensity stress group (n = 13). Participants in the latter group were exposed to an extremely strenuous mock prisoner of war (POW) exercise. Immediately after stress or control treatment, working memory and visuo-spatial declarative memory performances were measured by the digit span (DS) test and the Rey-Osterrieth complex figure (ROCF), respectively. Concurrently, stress levels were assessed by obtaining salivary cortisol measurements and subjectively by the NASA Task Load Index (TLX). As expected, exposure to high-intensity stress led to both robust cortisol increases and significant differences in TLX scores. Stress induction also significantly impaired DS and ROCF performances. Moreover, delta cortisol increases and ROCF performance in the POW stress group showed a significant negative correlation, while DS performances followed the same tendency. Summarizing, the current findings complement and extend previous work on hormonal stress effects, and the subsequent performance deterioration on two memory tests in a unique high-intensity stress environment.

  1. A holistic life cycle analysis of waste management scenarios at increasing source segregation intensity: The case of an Italian urban area

    International Nuclear Information System (INIS)

    Di Maria, Francesco; Micale, Caterina

    2014-01-01

    Highlights: • Waste management scenarios starting from different SS intensity were analyzed by LCA. • Several experimental data were utilized for the inventory. • Collection activities influences marginally global impact. • Maximum global environmental gain was achieved by SRF for coke substitution. - Abstract: Life cycle analysis of several waste management scenarios for an Italian urban area was performed on the basis of different source segregation collection (SS) intensities from 0% up to 52%. Source segregated waste was recycled and or/recovered by composting. Residual waste management options were by landfilling, incineration with energy recovery or solid recovered fuel (SRF) production to substitute for coal. The increase in fuel and materials consumption due to increase in SS had negligible influence on the environmental impact of the system. Recycling operations such as incineration and SRF were always advantageous for impact reduction. There was lower impact for an SS of 52% even though the difference with the SS intensity of 35% was quite limited, about 15%. In all the configurations analyzed, the best environmental performance was achieved for the management system producing SRF by the biodrying process

  2. Does aging with a cortical lesion increase fall-risk: Examining effect of age versus stroke on intensity modulation of reactive balance responses from slip-like perturbations.

    Science.gov (United States)

    Patel, Prakruti J; Bhatt, Tanvi

    2016-10-01

    We examined whether aging with and without a cerebral lesion such as stroke affects modulation of reactive balance response for recovery from increasing intensity of sudden slip-like stance perturbations. Ten young adults, older age-match adults and older chronic stroke survivors were exposed to three different levels of slip-like perturbations, level 1 (7.75m/s(2)), Level II (12.00m/s(2)) and level III (16.75m/s(2)) in stance. The center of mass (COM) state stability was computed as the shortest distance of the instantaneous COM position and velocity relative to base of support (BOS) from a theoretical threshold for backward loss of balance (BLOB). The COM position (XCOM/BOS) and velocity (ẊCOM/BOS) relative to BOS at compensatory step touchdown, compensatory step length and trunk angle at touchdown were also recorded. At liftoff, stability reduced with increasing perturbation intensity across all groups (main effect of intensity pbalance control, potentially contributing toward a higher fall risk in older stroke survivors. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  3. A holistic life cycle analysis of waste management scenarios at increasing source segregation intensity: The case of an Italian urban area

    Energy Technology Data Exchange (ETDEWEB)

    Di Maria, Francesco, E-mail: francesco.dimaria@unipg.it; Micale, Caterina

    2014-11-15

    Highlights: • Waste management scenarios starting from different SS intensity were analyzed by LCA. • Several experimental data were utilized for the inventory. • Collection activities influences marginally global impact. • Maximum global environmental gain was achieved by SRF for coke substitution. - Abstract: Life cycle analysis of several waste management scenarios for an Italian urban area was performed on the basis of different source segregation collection (SS) intensities from 0% up to 52%. Source segregated waste was recycled and or/recovered by composting. Residual waste management options were by landfilling, incineration with energy recovery or solid recovered fuel (SRF) production to substitute for coal. The increase in fuel and materials consumption due to increase in SS had negligible influence on the environmental impact of the system. Recycling operations such as incineration and SRF were always advantageous for impact reduction. There was lower impact for an SS of 52% even though the difference with the SS intensity of 35% was quite limited, about 15%. In all the configurations analyzed, the best environmental performance was achieved for the management system producing SRF by the biodrying process.

  4. Preparation of a liquid nitrogen target for measurement of γ-ray in the 14N(n,γ)15N reaction as an intensity standard in energy region up to 11 MeV

    International Nuclear Information System (INIS)

    Hirano, M.; Obayashi, H.; Sakane, H.; Shibata, M.; Kawade, K.; Taniguchi, A.

    2001-01-01

    For determination of relative γ-ray intensities up to 11 MeV in the 14 N(n,γ) 15 N reaction, we have developed a liquid nitrogen (N 2 ) target which contain no hydrogen (H) to improve the accuracy of γ-ray intensities. The ratio of the relative uncertainties for the liquid nitrogen to that for the melamine (C 3 H 6 N 6 ) widely used was improved by a factor of 2 above 2.2 MeV and a factor of 3 - 6 below 2.2 MeV. It has been shown that the liquid nitrogen target is useful for reduction of the 2.2 MeV γ-ray from the 1 H(n,γ) 2 H reaction and improvement of statistics. (author)

  5. Order of magnitude sensitivity increase in X-ray Fluorescence Computed Tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: theory and simulation.

    Science.gov (United States)

    Ahmad, Moiz; Bazalova, Magdalena; Xiang, Liangzhong; Xing, Lei

    2014-05-01

    The purpose of this study was to increase the sensitivity of XFCT imaging by optimizing the data acquisition geometry for reduced scatter X-rays. The placement of detectors and detector energy window were chosen to minimize scatter X-rays. We performed both theoretical calculations and Monte Carlo simulations of this optimized detector configuration on a mouse-sized phantom containing various gold concentrations. The sensitivity limits were determined for three different X-ray spectra: a monoenergetic source, a Gaussian source, and a conventional X-ray tube source. Scatter X-rays were minimized using a backscatter detector orientation (scatter direction > 110(°) to the primary X-ray beam). The optimized configuration simultaneously reduced the number of detectors and improved the image signal-to-noise ratio. The sensitivity of the optimized configuration was 10 μg/mL (10 pM) at 2 mGy dose with the mono-energetic source, which is an order of magnitude improvement over the unoptimized configuration (102 pM without the optimization). Similar improvements were seen with the Gaussian spectrum source and conventional X-ray tube source. The optimization improvements were predicted in the theoretical model and also demonstrated in simulations. The sensitivity of XFCT imaging can be enhanced by an order of magnitude with the data acquisition optimization, greatly enhancing the potential of this modality for future use in clinical molecular imaging.

  6. Increasing the Intensity over Time of an Electric-Assist Bike Based on the User and Route: The Bike Becomes the Gym

    Directory of Open Access Journals (Sweden)

    Daniel H. De La Iglesia

    2018-01-01

    Full Text Available Nowadays, many citizens have busy days that make finding time for physical activity difficult. Thus, it is important to provide citizens with tools that allow them to introduce physical activity into their lives as part of the day’s routine. This article proposes an app for an electric pedal-assist-system (PAS bicycle that increases the pedaling intensity so the bicyclist can achieve higher and higher levels of physical activity. The app includes personalized assist levels that have been adapted to the user’s strength/ability and a profile of the route, segmented according to its slopes. Additionally, a social component motivates interaction and competition between users based on a scoring system that shows the level of their performances. To test the training module, a case study in three different European countries lasted four months and included nine people who traveled 551 routes. The electric PAS bicycle with the app that increases intensity of physical activity shows promise for increasing levels of physical activity as a regular part of the day.

  7. Improvements in exercise performance with high-intensity interval training coincide with an increase in skeletal muscle mitochondrial content and function

    DEFF Research Database (Denmark)

    Jacobs, Robert Acton; Flueck, Daniela; Bonne, Thomas Christian

    2013-01-01

    sessions of HIT to determine the mechanisms explaining improvements in exercise performance. Sixteen untrained (43 +/- 6 ml.kg(-1).min(-1)) subjects completed six sessions of repeated (8-12) 60 s intervals of high-intensity cycling (100% peak power output elicited during incremental maximal exercise test...... (similar to 20 P = 0.026), as assessed by cytochrome c oxidase activity. Skeletal muscle deoxygenation also increased while maximal cardiac output, total hemoglobin, plasma volume, total blood volume, and relative measures of peripheral fatigue resistance were all unaltered with training. These results...

  8. Alteration in cardiac uncoupling proteins and eNOS gene expression following high-intensity interval training in favor of increasing mechanical efficiency.

    Science.gov (United States)

    Fallahi, Ali Asghar; Shekarfroush, Shahnaz; Rahimi, Mostafa; Jalali, Amirhossain; Khoshbaten, Ali

    2016-03-01

    High-intensity interval training (HIIT) increases energy expenditure and mechanical energy efficiency. Although both uncoupling proteins (UCPs) and endothelial nitric oxide synthase (eNOS) affect the mechanical efficiency and antioxidant capacity, their effects are inverse. The aim of this study was to determine whether the alterations of cardiac UCP2, UCP3, and eNOS mRNA expression following HIIT are in favor of increased mechanical efficiency or decreased oxidative stress. Wistar rats were divided into five groups: control group (n=12), HIIT for an acute bout (AT1), short term HIIT for 3 and 5 sessions (ST3 and ST5), long-term training for 8 weeks (LT) (6 in each group). The rats of the training groups were made to run on a treadmill for 60 min in three stages: 6 min running for warm-up, 7 intervals of 7 min running on treadmill with a slope of 5° to 20° (4 min with an intensity of 80-110% VO2max and 3 min at 50-60% VO2max), and 5-min running for cool-down. The control group did not participate in any exercise program. Rats were sacrificed and the hearts were extracted to analyze the levels of UCP2, UCP3 and eNOS mRNA by RT-PCR. UCP3 expression was increased significantly following an acute training bout. Repeated HIIT for 8 weeks resulted in a significant decrease in UCPs mRNA and a significant increase in eNOS expression in cardiac muscle. This study indicates that Long term HIIT through decreasing UCPs mRNA and increasing eNOS mRNA expression may enhance energy efficiency and physical performance.

  9. Solar flares associated coronal mass ejection accompanied with DH type II radio burst in relation with interplanetary magnetic field, geomagnetic storms and cosmic ray intensity

    Science.gov (United States)

    Chandra, Harish; Bhatt, Beena

    2018-04-01

    In this paper, we have selected 114 flare-CME events accompanied with Deca-hectometric (DH) type II radio burst chosen from 1996 to 2008 (i.e., solar cycle 23). Statistical analyses are performed to examine the relationship of flare-CME events accompanied with DH type II radio burst with Interplanetary Magnetic field (IMF), Geomagnetic storms (GSs) and Cosmic Ray Intensity (CRI). The collected sample events are divided into two groups. In the first group, we considered 43 events which lie under the CME span and the second group consists of 71 events which are outside the CME span. Our analysis indicates that flare-CME accompanied with DH type II radio burst is inconsistent with CSHKP flare-CME model. We apply the Chree analysis by the superposed epoch method to both set of data to find the geo-effectiveness. We observed different fluctuations in IMF for arising and decay phase of solar cycle in both the cases. Maximum decrease in Dst during arising and decay phase of solar cycle is different for both the cases. It is noted that when flare lie outside the CME span CRI shows comparatively more variation than the flare lie under the CME span. Furthermore, we found that flare lying under the CME span is more geo effective than the flare outside of CME span. We noticed that the time leg between IMF Peak value and GSs, IMF and CRI is on average one day for both the cases. Also, the time leg between CRI and GSs is on average 0 to 1 day for both the cases. In case flare lie under the CME span we observed high correlation (0.64) between CRI and Dst whereas when flare lie outside the CME span a weak correlation (0.47) exists. Thus, flare position with respect to CME span play a key role for geo-effectiveness of CME.

  10. Enhancing the aggressive intensity of hydrodynamic cavitation through a Venturi tube by increasing the pressure in the region where the bubbles collapse

    Science.gov (United States)

    Soyama, H.; Hoshino, J.

    2016-04-01

    In this paper, we used a Venturi tube for generating hydrodynamic cavitation, and in order to obtain the optimum conditions for this to be used in chemical processes, the relationship between the aggressive intensity of the cavitation and the downstream pressure where the cavitation bubbles collapse was investigated. The acoustic power and the luminescence induced by the bubbles collapsing were investigated under various cavitating conditions, and the relationships between these and the cavitation number, which depends on the upstream pressure, the downstream pressure at the throat of the tube and the vapor pressure of the test water, was found. It was shown that the optimum downstream pressure, i.e., the pressure in the region where the bubbles collapse, increased the aggressive intensity by a factor of about 100 compared to atmospheric pressure without the need to increase the input power. Although the optimum downstream pressure varied with the upstream pressure, the cavitation number giving the optimum conditions was constant for all upstream pressures.

  11. Enhancing the aggressive intensity of hydrodynamic cavitation through a Venturi tube by increasing the pressure in the region where the bubbles collapse

    Directory of Open Access Journals (Sweden)

    H. Soyama

    2016-04-01

    Full Text Available In this paper, we used a Venturi tube for generating hydrodynamic cavitation, and in order to obtain the optimum conditions for this to be used in chemical processes, the relationship between the aggressive intensity of the cavitation and the downstream pressure where the cavitation bubbles collapse was investigated. The acoustic power and the luminescence induced by the bubbles collapsing were investigated under various cavitating conditions, and the relationships between these and the cavitation number, which depends on the upstream pressure, the downstream pressure at the throat of the tube and the vapor pressure of the test water, was found. It was shown that the optimum downstream pressure, i.e., the pressure in the region where the bubbles collapse, increased the aggressive intensity by a factor of about 100 compared to atmospheric pressure without the need to increase the input power. Although the optimum downstream pressure varied with the upstream pressure, the cavitation number giving the optimum conditions was constant for all upstream pressures.

  12. Increased signal intensity of prostate lesions on high b-value diffusion-weighted images as a predictive sign of malignancy

    International Nuclear Information System (INIS)

    Quentin, Michael; Schimmoeller, Lars; Antoch, Gerald; Blondin, Dirk; Arsov, Christian; Rabenalt, Robert; Albers, Peter

    2014-01-01

    The evaluation of lesions detected in prostate magnetic resonance imaging (MRI) with increased signal intensity (SI) on high b-value diffusion-weighted images as a sign of malignancy. One hundred and three consecutive patients with prostate MRI examination and MRI-guided in-bore biopsy were retrospectively included in the study. MRI-guided in-bore biopsy histologically confirmed prostate cancer in 50 patients (n = 92 lesions). The other 53 patients (n = 122 lesions) had negative bioptical results. In patients with histologically confirmed prostate cancer, 46 of the 92 lesions had visually increased SI on the high b-value images compared with the peripheral zone (SI = +27 ± 16%) or the central gland (SI = +37 ± 19%, P < 0.001 respectively). In patients with a negative biopsy, ten of the 122 lesions had visually increased SI (compared with the peripheral zone, SI = +29 ± 18%, and with the central gland, SI = +41 ± 15%, P < 0.001 respectively). Neither the apparent diffusion coefficient (ADC) values nor the Gleason Score of lesions with increased SI were significantly different from lesions without increased SI. Visually increased SI on the high b-value images of diffusion-weighted imaging using standard b-values is a sign of malignancy but can occasionally also be a feature of benign lesions. However, it does not indicate more aggressive tumours. (orig.)

  13. High-Intensity Progressive Resistance Training Increases Strength With No Change in Cardiovascular Function and Autonomic Neural Regulation in Older Adults.

    Science.gov (United States)

    Kanegusuku, Hélcio; Queiroz, Andréia C; Silva, Valdo J; de Mello, Marco T; Ugrinowitsch, Carlos; Forjaz, Cláudia L

    2015-07-01

    The effects of high-intensity progressive resistance training (HIPRT) on cardiovascular function and autonomic neural regulation in older adults are unclear. To investigate this issue, 25 older adults were randomly divided into two groups: control (CON, N = 13, 63 ± 4 years; no training) and HIPRT (N = 12, 64 ± 4 years; 2 sessions/week, 7 exercises, 2–4 sets, 10–4 RM). Before and after four months, maximal strength, quadriceps cross-sectional area (QCSA), clinic and ambulatory blood pressures (BP), systemic hemodynamics, and cardiovascular autonomic modulation were measured. Maximal strength and QCSA increased in the HIPRT group and did not change in the CON group. Clinic and ambulatory BP, cardiac output, systemic vascular resistance, stroke volume, heart rate, and cardiac sympathovagal balance did not change in the HIPRT group or the CON group. In conclusion, HIPRT was effective at increasing muscle mass and strength without promoting changes in cardiovascular function or autonomic neural regulation.

  14. Classifying and assembling two-dimensional X-ray laser diffraction patterns of a single particle to reconstruct the three-dimensional diffraction intensity function: resolution limit due to the quantum noise

    International Nuclear Information System (INIS)

    Tokuhisa, Atsushi; Taka, Junichiro; Kono, Hidetoshi; Go, Nobuhiro

    2012-01-01

    A new algorithm is developed for reconstructing the high-resolution three-dimensional diffraction intensity function of a globular biological macromolecule from many quantum-noise-limited two-dimensional X-ray laser diffraction patterns, each for an unknown orientation. The structural resolution is expressed as a function of the incident X-ray intensity and quantities characterizing the target molecule. A new two-step algorithm is developed for reconstructing the three-dimensional diffraction intensity of a globular biological macromolecule from many experimentally measured quantum-noise-limited two-dimensional X-ray laser diffraction patterns, each for an unknown orientation. The first step is classification of the two-dimensional patterns into groups according to the similarity of direction of the incident X-rays with respect to the molecule and an averaging within each group to reduce the noise. The second step is detection of common intersecting circles between the signal-enhanced two-dimensional patterns to identify their mutual location in the three-dimensional wavenumber space. The newly developed algorithm enables one to detect a signal for classification in noisy experimental photon-count data with as low as ∼0.1 photons per effective pixel. The wavenumber of such a limiting pixel determines the attainable structural resolution. From this fact, the resolution limit due to the quantum noise attainable by this new method of analysis as well as two important experimental parameters, the number of two-dimensional patterns to be measured (the load for the detector) and the number of pairs of two-dimensional patterns to be analysed (the load for the computer), are derived as a function of the incident X-ray intensity and quantities characterizing the target molecule

  15. Increased signal intensity of the cochlea on pre- and post-contrast enhanced 3D-FLAIR in patients with vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi [Nagoya University, Department of Radiology, Graduate School of Medicine, Nagoya (Japan); Fukatsu, Hiroshi [Aichi Medical University Hospital, Department of Medical Informatics, Nagakute (Japan); Nakashima, Tsutomu [Nagoya University, Department of Otorhinolaryngology, Graduate School of Medicine, Nagoya (Japan)

    2009-12-15

    In the vestibular schwannoma patients, the pathophysiologic mechanism of inner ear involvement is still unclear. We investigated the status of the cochleae in patients with vestibular schwannoma by evaluating the signal intensity of cochlear fluid on pre- and post-contrast enhanced thin section three-dimensional fluid-attenuated inversion recovery (3D-FLAIR). Twenty-eight patients were retrospectively analyzed. Post-contrast images were obtained in 18 patients, and 20 patients had the records of their pure-tone audiometry. Regions of interest of both cochleae (C) and of the medulla oblongata (M) were determined on 3D-FLAIR images by referring to 3D heavily T2-weighted images on a workstation. The signal intensity ratio between C and M on the 3D-FLAIR images (CM ratio) was then evaluated. In addition, correlation between the CM ratio and the hearing level was also evaluated. The CM ratio of the affected side was significantly higher than that of the unaffected side (p < 0.001). In the affected side, post-contrast signal elevation was observed (p < 0.005). In 13 patients (26 cochleae) who underwent both gadolinium injection and the pure-tone audiometry, the post-contrast CM ratio correlated with hearing level (p < 0.05). The results of the present study suggest that alteration of cochlear fluid composition and increased permeability of the blood-labyrinthine barrier exist in the affected side in patients with vestibular schwannoma. Furthermore, although weak, positive correlation between post-contrast cochlear signal intensity on 3D-FLAIR and hearing level warrants further study to clarify the relationship between 3D-FLAIR findings and prognosis of hearing preservation surgery. (orig.)

  16. Increased signal intensity of the cochlea on pre- and post-contrast enhanced 3D-FLAIR in patients with vestibular schwannoma

    International Nuclear Information System (INIS)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi; Fukatsu, Hiroshi; Nakashima, Tsutomu

    2009-01-01

    In the vestibular schwannoma patients, the pathophysiologic mechanism of inner ear involvement is still unclear. We investigated the status of the cochleae in patients with vestibular schwannoma by evaluating the signal intensity of cochlear fluid on pre- and post-contrast enhanced thin section three-dimensional fluid-attenuated inversion recovery (3D-FLAIR). Twenty-eight patients were retrospectively analyzed. Post-contrast images were obtained in 18 patients, and 20 patients had the records of their pure-tone audiometry. Regions of interest of both cochleae (C) and of the medulla oblongata (M) were determined on 3D-FLAIR images by referring to 3D heavily T2-weighted images on a workstation. The signal intensity ratio between C and M on the 3D-FLAIR images (CM ratio) was then evaluated. In addition, correlation between the CM ratio and the hearing level was also evaluated. The CM ratio of the affected side was significantly higher than that of the unaffected side (p < 0.001). In the affected side, post-contrast signal elevation was observed (p < 0.005). In 13 patients (26 cochleae) who underwent both gadolinium injection and the pure-tone audiometry, the post-contrast CM ratio correlated with hearing level (p < 0.05). The results of the present study suggest that alteration of cochlear fluid composition and increased permeability of the blood-labyrinthine barrier exist in the affected side in patients with vestibular schwannoma. Furthermore, although weak, positive correlation between post-contrast cochlear signal intensity on 3D-FLAIR and hearing level warrants further study to clarify the relationship between 3D-FLAIR findings and prognosis of hearing preservation surgery. (orig.)

  17. Diffuse alopecia areata is associated with intense inflammatory infiltration and CD8+ T cells in hair loss regions and an increase in serum IgE level

    Directory of Open Access Journals (Sweden)

    Ying Zhao

    2012-01-01

    Full Text Available Background: Mechanism leading to an abrupt hair loss in diffuse alopecia areata (AA remains unclear. Aims: To explore the characteristics of diffuse AA and possible factors involved in its pathogenesis. Methods: Clinical and laboratory data of 17 diffuse AA patients and 37 patchy AA patients were analyzed retrospectively. Serum IgE level was evaluated in all diffuse and patchy AA patients, as well as 27 healthy subjects without hair loss to serve as normal control. Univariate analysis was performed using Fisher′s exact test and Wilcoxon rank-sum test. Associations between inflammatory cell infiltration and laboratory values were analyzed using Spearman rank correlation test. Results: The mean age of patients with diffuse AA was 27 years with a mean disease duration of 1.77 months. All of them presented in spring or summer with an acute onset of diffuse hair loss preceded by higher incidence of scalp pruritus. Although no statistically significant difference on the incidence of atopic disease among three groups has been found, serum IgE level in diffuse AA was higher than that in healthy controls, but was comparable to that in patchy AA group. Histopathology of lesional scalp biopsies showed more intense infiltration comprising of mononuclear cells, eosinophils, CD3 + , and CD8 + T cells around hair bulbs in diffuse AA group than in patchy AA group. Moreover, IgE level in diffuse AA patients positively correlated with intensity of infiltration by mononuclear cells, eosinophils, and CD8 + T cells. Conclusions: Hypersensitivity may be involved in pathogenesis of diffuse AA. The acute onset of diffuse AA may be related to intense local inflammatory infiltration of hair loss region and an increase in serum IgE level.

  18. Increased signal intensity at the proximal patellar tendon: correlation between MR imaging and histology in eight cadavers and clinical MR imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Seong Jong; Jin, Wook; Yoon, So Hee; Park, So Young [Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Yong-Koo [Kyung Hee University Medical Center, Department of Pathology, Seoul (Korea, Republic of); Kim, Gou Young [Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Department of Pathology, Seoul (Korea, Republic of); Lee, Jung Eun; Park, Ji Seon; Ryu, Kyung Nam [Kyung Hee University Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2015-10-15

    We set out to investigate the cause of persistently increased signal intensity (SI) in the posterior portion of the proximal patellar tendon (pPT) on T1-weighted images (T1WI). MR imaging was performed in eight cadavers, followed by gross histological examination. In addition, 84 patients without trauma history or anterior knee pain were included to compare the SI of the PTs. The patients were divided according to their age, sex, and Kellgren-Lawrence (KL) grades. The length and thickness of the increased SI portion in the pPT and whole PT (wPT) on T1WI were recorded. Histological specimens demonstrated that the adipose tissue, vessels, and perivascular connective tissue invaginated into the posterior portion of the pPT. This histological anatomy corresponded to the pPT signal change on MR imaging. There was linear and interdigitating increased SI of the pPT in all of the 84 patients (100 %). There were no differences in the lengths and thicknesses of the increased SI portion of pPTs and wPTs according to age, sex, and KL grade (all p > 0.05). The increased SI of the pPT on T1WI and fluid-sensitive MR images results from invaginating fat, vessels, and perivascular connective tissue. It is not pathological, but a normal and common finding. (orig.)

  19. l-glutamine and l-alanine supplementation increase glutamine-glutathione axis and muscle HSP-27 in rats trained using a progressive high-intensity resistance exercise.

    Science.gov (United States)

    Leite, Jaqueline Santos Moreira; Raizel, Raquel; Hypólito, Thaís Menezes; Rosa, Thiago Dos Santos; Cruzat, Vinicius Fernandes; Tirapegui, Julio

    2016-08-01

    In this study we investigated the chronic effects of oral l-glutamine and l-alanine supplementation, either in their free or dipeptide form, on glutamine-glutathione (GLN-GSH) axis and cytoprotection mediated by HSP-27 in rats submitted to resistance exercise (RE). Forty Wistar rats were distributed into 5 groups: sedentary; trained (CTRL); and trained supplemented with l-alanyl-l-glutamine, l-glutamine and l-alanine in their free form (GLN+ALA), or free l-alanine (ALA). All trained animals were submitted to a 6-week ladder-climbing protocol. Supplementations were offered in a 4% drinking water solution for 21 days prior to euthanasia. Plasma glutamine, creatine kinase (CK), myoglobin (MYO), and erythrocyte concentration of reduced GSH and glutathione disulfide (GSSG) were measured. In tibialis anterior skeletal muscle, GLN-GSH axis, thiobarbituric acid reactive substances (TBARS), and the expression of heat shock factor 1 (HSF-1), 27-kDa heat shock protein (HSP-27), and glutamine synthetase were determined. In CRTL animals, high-intensity RE reduced muscle glutamine levels and increased GSSG/GSH rate and TBARS, as well as augmented plasma CK and MYO levels. Conversely, l-glutamine-supplemented animals showed an increase in plasma and muscle levels of glutamine, with a reduction in GSSG/GSH rate, TBARS, and CK. Free l-alanine administration increased plasma glutamine concentration and lowered muscle TBARS. HSF-1 and HSP-27 were high in all supplemented groups when compared with CTRL (p alanine, in both a free or dipeptide form, improve the GLN-GSH axis and promote cytoprotective effects in rats submitted to high-intensity RE training.

  20. Are gender differences in upper-body power generated by elite cross-country skiers augmented by increasing the intensity of exercise?

    Science.gov (United States)

    Hegge, Ann Magdalen; Myhre, Kenneth; Welde, Boye; Holmberg, Hans-Christer; Sandbakk, Øyvind

    2015-01-01

    In the current study, we evaluated the impact of exercise intensity on gender differences in upper-body poling among cross-country skiers, as well as the associated differences in aerobic capacity, maximal strength, body composition, technique and extent of training. Eight male and eight female elite skiers, gender-matched for level of performance by FIS points, carried out a 4-min submaximal, and a 3-min and 30-sec maximal all-out test of isolated upper-body double poling on a Concept2 ski ergometer. Maximal upper-body power and strength (1RM) were determined with a pull-down exercise. In addition, body composition was assessed with a DXA scan and training during the previous six months quantified from diaries. Relative to the corresponding female values (defined as 100%), the power output produced by the men was 88%, 95% and 108% higher during the submaximal, 3-min and 30-sec tests, respectively, and peak power in the pull-down strength exercise was 118% higher (all Pgender differences in upper-body power among cross-country skiers augmented as the intensity of exercise increased. The gender differences observed here are greater than those reported previously for both lower- and whole-body sports and coincided with greater peak aerobic capacity and maximal upper-body strength, relatively more muscle mass in the upper-body, and more extensive training of upper-body strength and endurance among the male skiers.

  1. Measurement of secondary cosmic ray intensity at Regener-Pfotzer height using low-cost weather balloons and its correlation with solar activity

    OpenAIRE

    Sarkar, Ritabrata; Chakrabarti, Sandip K.; Pal, Partha Sarathi; Bhowmick, Debashis; Bhattacharya, Arnab

    2017-01-01

    Cosmic ray flux in our planetary system is primarily modulated by solar activity. Radiation effects of cosmic rays on the Earth strongly depend on latitude due to the variation of the geomagnetic field strength. To study these effects we carried out a series of measurements of the radiation characteristics in the atmosphere due to cosmic rays from various places (geomagnetic latitude: ~ 14.50 deg N) in West Bengal, India, located near the Tropic of Cancer, for several years (2012-2016) partic...

  2. Increased frequency of spontaneous and X-ray-induced chromosomal aberrations in lymphocytes from neonates and the influence of caffeine

    International Nuclear Information System (INIS)

    Karsdon, J.; Rijn, J. van; Berger, H.

    1989-01-01

    The authors have examined lymphocytes from human preterm (PT) and fullterm (FT) babies for an effect of gestational age (GA) on chromosomal aberrations either occurring spontaneously or indiced by treatment with X-rays alone; or with caffeine supplementation in comparison to the lymphocytes of healthy adults. (AD). Per cent of abnormal cells (% Abn) was used as an indicator of chromosome sensitivy to the different treatments. PT babies had significantly higher spontaneous and X-ray-induced % Abn values than AD, but were comparable to FT. After X-iradiation + caffeine the yield of aberrations in any 2 groups was not significantly different. Chromosomal sensitivity may resuult from factors other than GA. This in vitro model may permit study of the mechanisms of chromosomal damage repair and prevention of free radical damage of DNA during the perinatal period. (author). 33 refs.; 1 fig.; 3 tabs

  3. Optimizing shape uniformity and increasing structure heights of deep reactive ion etched silicon x-ray lenses

    DEFF Research Database (Denmark)

    Stöhr, Frederik; Wright, Jonathan; Simons, Hugh

    2015-01-01

    Line-focusing compound silicon x-ray lenses with structure heights exceeding 300 μm were fabricated using deep reactive ion etching. To ensure profile uniformity over the full height, a new strategy was developed in which the perimeter of the structures was defined by trenches of constant width....... The remaining sacrificial material inside the lens cavities was removed by etching through the silicon wafer. Since the wafers become fragile after through-etching, they were then adhesively bonded to a carrier wafer. Individual chips were separated using laser micro machining and the 3D shape of fabricated...... analysis, where a slight bowing of the lens sidewalls and an insufficiently uniform apex region are identified as resolution-limiting factors. Despite these, the proposed fabrication route proved a viable approach for producing x-ray lenses with large structure heights and provides the means to improve...

  4. Increase in tumor control and normal tissue complication probabilities in advanced head-and-neck cancer for dose-escalated intensity-modulated photon and proton therapy

    Directory of Open Access Journals (Sweden)

    Annika eJakobi

    2015-11-01

    Full Text Available Introduction:Presently used radio-chemotherapy regimens result in moderate local control rates for patients with advanced head and neck squamous cell carcinoma (HNSCC. Dose escalation (DE may be an option to improve patient outcome, but may also increase the risk of toxicities in healthy tissue. The presented treatment planning study evaluated the feasibility of two DE levels for advanced HNSCC patients, planned with either intensity-modulated photon therapy (IMXT or proton therapy (IMPT.Materials and Methods:For 45 HNSCC patients, IMXT and IMPT treatment plans were created including DE via a simultaneous integrated boost (SIB in the high-risk volume, while maintaining standard fractionation with 2 Gy per fraction in the remaining target volume. Two DE levels for the SIB were compared: 2.3 Gy and 2.6 Gy. Treatment plan evaluation included assessment of tumor control probabilities (TCP and normal tissue complication probabilities (NTCP.Results:An increase of approximately 10% in TCP was estimated between the DE levels. A pronounced high-dose rim surrounding the SIB volume was identified in IMXT treatment. Compared to IMPT, this extra dose slightly increased the TCP values and to a larger extent the NTCP values. For both modalities, the higher DE level led only to a small increase in NTCP values (mean differences < 2% in all models, except for the risk of aspiration, which increased on average by 8% and 6% with IMXT and IMPT, respectively, but showed a considerable patient dependence. Conclusions:Both DE levels appear applicable to patients with IMXT and IMPT since all calculated NTCP values, except for one, increased only little for the higher DE level. The estimated TCP increase is of relevant magnitude. The higher DE schedule needs to be investigated carefully in the setting of a prospective clinical trial, especially regarding toxicities caused by high local doses that lack a sound dose response description, e.g., ulcers.

  5. Preliminary investigation of the NMR, optical and x-ray CT dose-response of polymer gel dosimeters with cosolvents and increased crosslinker levels

    International Nuclear Information System (INIS)

    Koeva, V I; McAuley, K B; Jirasek, A; Schreiner, L J

    2009-01-01

    Three co-solvents (glycerol, N-propanol and isopropanol) have been investigated for increasing the solubility of N,N'-methylene-bisacrylamide (Bis) crosslinker in polymer gel dosimeter recipes. Using isopropanol, the crosslinker solubility increased from approximately from 3 to 10% by weight, enabling the manufacture of polymer gel dosimeters with higher levels of crosslinking than was previously possible. The new dosimeter recipes can be imaged effectively using Nuclear Magnetic Resonance (NMR), optical and x-ray Computed Tomography (CT) techniques.

  6. Preliminary investigation of the NMR, optical and x-ray CT dose-response of polymer gel dosimeters with cosolvents and increased crosslinker levels

    Energy Technology Data Exchange (ETDEWEB)

    Koeva, V I; McAuley, K B [Chemical Engineering Department, Queen' s University, Kingston, K7L 3N6 (Canada); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, V8W 6V5 (Canada); Schreiner, L J [Cancer Centre of Southeastern Ontario, Kingston, K7L 5P9 (Canada)], E-mail: Kim.McAuley@chee.queensu.ca

    2009-05-01

    Three co-solvents (glycerol, N-propanol and isopropanol) have been investigated for increasing the solubility of N,N'-methylene-bisacrylamide (Bis) crosslinker in polymer gel dosimeter recipes. Using isopropanol, the crosslinker solubility increased from approximately from 3 to 10% by weight, enabling the manufacture of polymer gel dosimeters with higher levels of crosslinking than was previously possible. The new dosimeter recipes can be imaged effectively using Nuclear Magnetic Resonance (NMR), optical and x-ray Computed Tomography (CT) techniques.

  7. Increase of (CdSe/ZnS)Cys quantum dot luminescence intensity in the presence of TPPS{sub 4} porphyrin

    Energy Technology Data Exchange (ETDEWEB)

    Parra, Gustavo G.; Borissevitch, Iouri E. [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filosofia, Ciencias e Letras de Ribeirao Preto. Dept. de Fisica; Kuzmin, Vladimir A. [Emanuel Institute of Biophysical Chemistry, RAS-RU, Moscow (Russian Federation); Oleinikov, Vladimir A. [Shemyakin and Ovchinnikov Institute of Biooganic Cemistry, RAS-RU, Moscow (Russian Federation)

    2012-07-01

    Full text: Nanocrystal semiconductor particles or Quantum Dots (QD) possess extraordinary photophysical characteristics, such as extreme high fluorescence quantum yield and optical absorption and very narrow fluorescence band, which can be easily shifted by changing of QD particle size. Due to these characteristics, QD is promising for fluorescence cancer diagnostics and photodynamic treatment. The efficiency of these processes can be in- creased by energy transfer between QD and classic fluorescence probes and photosensitizers (PS). In this work we present on the study of the increase of (CdSe/ZnS)Cys quantum dot luminescence intensity, stimulated by interaction with TPPS{sub 4} porphyrin. The optical absorption and steady-state and time-resolved fluorescence techniques were employed. Water soluble QD (CdSe/ZnS) with emission at 580 nm, functionalized with cysteine (Cys), were studied. TPPS{sub 4} porphyrin was used as a stimulator of QD luminescence. All experiments were realized in PBS buffer (pH 7.3; 7.5 mM) in Milli-Q quality water. The TPPS{sub 4} adding into the QD solutions until the 5{mu}M concentration produced an increase in QD luminescence intensity and lifetime, while for TPPS{sub 4} concentrations higher than 20{mu}M the reduction of the fluorescence intensity was observed, the emission spectra and fluorescence decays profile being unchanged. This effect can not be due to the electrostatic interaction between (CdSe/ZnS)Cys and TPPS{sub 4} because both, (CdSe/ZnS)Cys and TPPS{sub 4}, are negatively charged. We suppose that TPPS{sub 4} porphyrin interacts directly with QD (ZnS) shell, reducing the dangling bound number. This reduction decreases, in turn, the probability of nonradiative ways of the excitation energy dissipation. When the majority of dangling bound is occupied by the TPPS{sub 4} molecules, the effect of QD luminescence reduction (quenching) by porphyrin predominates, probably, via the energy transfer from QD to TPPS{sub 4}. However

  8. The influence of increasing dietary fat or protein on the efficiency of broiler chickens exposed to low levels of gamma-rays

    International Nuclear Information System (INIS)

    Ezzat, I.E.; Ghazalah, A.A.

    2002-01-01

    A total of 400 one-day-old chicks, from hubbard line of meat production type, were used in this study. The chicks were divided into three nutritional groups. The second group was fed on a high protein feed containing 3% protein higher than that of the normal diet (group one). The fat level was increased by 4% in the feed of the third group over the value of the normal diet. Each group was divided again into four subgroup treatments (To, T1, T2, and T3) according to the exposure to gamma rays in a single or multi doses. The aim of this study was to compare between the nutritional types and its combinations with the applied doses of gamma rays on broiler performance. The results can be summarized as follows: The broiler chicks fed on the high fat ration and exposed to 0.25 Gy of gamma-rays four times (group 111, T3) recorded the highest body weight gain along the duration of the experiment. in general, the stimulation effect of the gamma-ray doses applied herein was obvious during the period of rapid growth (0-4 weeks of age) then it was followed by retardation in growth rate. The group of chicks fed on a diet containing high fat (group 111), achieved the crude fiber and nitrogen extract digestibility's. Increase of dietary protein was accompanied by a significant increase in carcass protein, water and ash content. Carcass fat was increased while carcass water was decreased with low level of gamma rays

  9. Synchrotron topographic evaluation of strain around craters generated by irradiation with X-ray pulses from free electron laser with different intensities

    Czech Academy of Sciences Publication Activity Database

    Wierzchowski, W.; Wieteska, K.; Sobierajski, R.; Klinger, D.; Pelka, J.; Zymierska, D.; Paulmann, C.; Hau-Riege, S.P.; London, R.A.; Graf, A.; Burian, Tomáš; Chalupský, Jaromír; Gaudin, J.; Krzywinski, J.; Moeller, S.; Messerschmidt, M.; Bozek, J.; Bostedt, C.

    2015-01-01

    Roč. 364, Dec (2015), s. 20-26 ISSN 0168-583X Institutional support: RVO:68378271 Keywords : x-ray free electron laser * soft x-ray lasers * irradiation with femtosecond pulses * silicon Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 1.389, year: 2015

  10. Catalog of gamma-rays unplaced in radioactive decay schemes

    International Nuclear Information System (INIS)

    Narita, Tsutomu; Kitao, Kensuke.

    1991-03-01

    A catalog is made for gamma-rays emitted in decay of radioactive nuclides but not placed in their decay schemes. It consists of two tables. In Table 1, the number of these unplaced gamma-ray components by a nuclide is given together with the fraction of total intensity of these gamma-rays to that of all observed gamma-rays. In Table 2, the unplaced gamma-rays are arranged in order of increasing energy. Each line of this table contains the gamma-ray energy, intensity, nuclide identification, and energies and intensities of the most prominent gamma-rays from the decay of the radionuclides. This catalog is a compilation from Evaluated Nuclear Structure Data File (ENSDF) maintained by National Nuclear Data Center at Brookhaven National Laboratory, of at February 1990. (author)

  11. Development of confocal micro X-ray fluorescence instrument using two X-ray beams

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Nakano, Kazuhiko; Ding Xunliang

    2007-01-01

    A new confocal micro X-ray fluorescence instrument was developed. This instrument has two independent micro X-ray tubes with Mo targets. A full polycapillary X-ray lens was attached to each X-ray tube. Another half polycapillary lens was attached to a silicon drift X-ray detector (SDD). The focal spots of the three lenses were adjusted to a common position. The effects of the excitation of two X-ray beams were investigated. The instrument enabled highly sensitive three-dimensional X-ray fluorescence analysis. We confirmed that the X-ray fluorescence intensity from the sample increased by applying the two independent X-ray tubes in confocal configuration. Elemental depth profiling of black wheat was demonstrated with the result that each element in the surface coat of a wheat grain showed unique distribution

  12. The rise of the photosynthetic rate when light intensity increases is delayed in ndh gene-defective tobacco at high but not at low CO2 concentrations

    Directory of Open Access Journals (Sweden)

    Mercedes eMartin

    2015-02-01

    Full Text Available The 11 plastid ndh genes have hovered frequently on the edge of dispensability, being absent in the plastid DNA of many algae and certain higher plants. We have compared the photosynthetic activity of tobacco (Nicotiana tabacum, cv. Petit Havana with five transgenic lines (ndhF, pr-ndhF, T181D, T181A and ndhF FC and found that photosynthetic performance is impaired in transgenic ndhF-defective tobacco plants at rapidly fluctuating light intensities and higher than ambient CO2 concentrations. In contrast to wild type and ndhF FC, which reach the maximum photosynthetic rate in less than one min when light intensity suddenly increases, ndh defective plants (ndhF and T181A show up to a 5 min delay in reaching the maximum photosynthetic rate at CO2 concentrations higher than the ambient 360 ppm. Net photosynthesis was determined at different CO2 concentrations when sequences of 130, 870, 61, 870 and 130 μmol m−2 s−1 PAR sudden light changes were applied to leaves and photosynthetic efficiency and entropy production were determined as indicators of photosynthesis performance. The two ndh-defective plants, ndhF and T181A, had lower photosynthetic efficiency and higher entropy production than wt, ndhF FC and T181D tobacco plants, containing full functional ndh genes, at CO2 concentrations above 400 ppm. We propose that the Ndh complex improves cyclic electron transport by adjusting the redox level of transporters during the low light intensity stage. In ndhF-defective strains, the supply of electrons through the Ndh complex fails, transporters remain over-oxidized (specially at high CO2 concentrations and the rate of cyclic electron transport is low, impairing the ATP level required to rapidly reach high CO2 fixation rates in the following high light phase. Hence, ndh genes could be dispensable at low but not at high atmospheric concentrations of CO2.

  13. Sodium bicarbonate ingestion augments the increase in PGC-1α mRNA expression during recovery from intense interval exercise in human skeletal muscle.

    Science.gov (United States)

    Percival, Michael E; Martin, Brian J; Gillen, Jenna B; Skelly, Lauren E; MacInnis, Martin J; Green, Alex E; Tarnopolsky, Mark A; Gibala, Martin J

    2015-12-01

    We tested the hypothesis that ingestion of sodium bicarbonate (NaHCO3) prior to an acute session of high-intensity interval training (HIIT) would augment signaling cascades and gene expression linked to mitochondrial biogenesis in human skeletal muscle. On two occasions separated by ∼1 wk, nine men (mean ± SD: age 22 ± 2 yr, weight 78 ± 13 kg, V̇O(2 peak) 48 ± 8 ml·kg(-1)·min(-1)) performed 10 × 60-s cycling efforts at an intensity eliciting ∼90% of maximal heart rate (263 ± 40 W), interspersed with 60 s of recovery. In a double-blind, crossover manner, subjects ingested a total of 0.4 g/kg body weight NaHCO3 before exercise (BICARB) or an equimolar amount of a placebo, sodium chloride (PLAC). Venous blood bicarbonate and pH were elevated at all time points after ingestion (P 0.05). However, the increase in PGC-1α mRNA expression after 3 h of recovery was higher in BICARB vs. PLAC (approximately sevenfold vs. fivefold compared with rest, P < 0.05). We conclude that NaHCO3 before HIIT alters the mRNA expression of this key regulatory protein associated with mitochondrial biogenesis. The elevated PGC-1α mRNA response provides a putative mechanism to explain the enhanced mitochondrial adaptation observed after chronic HIIT supplemented with NaHCO3 in rats. Copyright © 2015 the American Physiological Society.

  14. High-intensity exercise training increases the diversity and metabolic capacity of the mouse distal gut microbiota during diet-induced obesity.

    Science.gov (United States)

    Denou, Emmanuel; Marcinko, Katarina; Surette, Michael G; Steinberg, Gregory R; Schertzer, Jonathan D

    2016-06-01

    Diet and exercise underpin the risk of obesity-related metabolic disease. Diet alters the gut microbiota, which contributes to aspects of metabolic disease during obesity. Repeated exercise provides metabolic benefits during obesity. We assessed whether exercise could oppose changes in the taxonomic and predicted metagenomic characteristics of the gut microbiota during diet-induced obesity. We hypothesized that high-intensity interval training (HIIT) would counteract high-fat diet (HFD)-induced changes in the microbiota without altering obesity in mice. Compared with chow-fed mice, an obesity-causing HFD decreased the Bacteroidetes-to-Firmicutes ratio and decreased the genetic capacity in the fecal microbiota for metabolic pathways such as the tricarboxylic acid (TCA) cycle. After HFD-induced obesity was established, a subset of mice were HIIT for 6 wk, which increased host aerobic capacity but did not alter body or adipose tissue mass. The effects of exercise training on the microbiota were gut segment dependent and more extensive in the distal gut. HIIT increased the alpha diversity and Bacteroidetes/Firmicutes ratio of the distal gut and fecal microbiota during diet-induced obesity. Exercise training increased the predicted genetic capacity related to the TCA cycle among other aspects of metabolism. Strikingly, the same microbial metabolism indexes that were increased by exercise were all decreased in HFD-fed vs. chow diet-fed mice. Therefore, exercise training directly opposed some of the obesity-related changes in gut microbiota, including lower metagenomic indexes of metabolism. Some host and microbial pathways appeared similarly affected by exercise. These exercise- and diet-induced microbiota interactions can be captured in feces. Copyright © 2016 the American Physiological Society.

  15. Factors Associated With the Increasing Rates of Discharges Directly Home From Intensive Care Units-A Direct From ICU Sent Home Study.

    Science.gov (United States)

    Lau, Vincent I; Priestap, Fran A; Lam, Joyce N H; Ball, Ian M

    2018-02-01

    To evaluate the relationship between rates of discharge directly to home (DDH) from the intensive care unit (ICU) and bed availability (ward and ICU). Also to identify patient characteristics that make them candidates for safe DDH and describe transfer delay impact on length of stay (LOS). Retrospective cohort study of all adult patients who survived their stay in our medical-surgical-trauma ICU between April 2003 and March 2015. Median age was 49 years (interquartile range [IQR]: 33.5-60.4), and the majority of the patients were males (54.8%). Median number of preexisting comorbidities was 5 (IQR: 2-7) diagnoses. Discharge directly to home increased from 28 (3.1% of all survivors) patients in 2003 to 120 (12.5%) patients in 2014. The mean annual rate of DDH was between 11% and 12% over the last 6 years. Approximately 62% (n = 397) of patients waited longer than 4 hours for a ward bed, with a median delay of 2.0 days (IQR: 0.5-4.7) before being DDH. There was an inverse correlation between ICU occupancy and DDH rates ( r P = -.55, P < .0001, 95% confidence interval [CI] = -0.36 to -0.69, R 2 = .29). There was no correlation with ward occupancy and DDH rates ( r s = -.055, P = .64, 95% CI = -0.25 to 0.21). The DDH rates have been increasing over time at our institution and were inversely correlated with ICU bed occupancy but were not associated with ward occupancy. The DDH patients are young, have few comorbidities on admission, and few discharge diagnoses, which are usually reversible single system problems with low disease burden. Transfers to the ward are delayed in a majority of cases, leading to increased ICU LOS and likely increased overall hospital LOS as well.

  16. Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?

    International Nuclear Information System (INIS)

    Hermanto, Ulrich; Frija, Erik K.; Lii, MingFwu J.; Chang, Eric L.; Mahajan, Anita; Woo, Shiao Y.

    2007-01-01

    Purpose: To determine whether intensity-modulated radiotherapy (IMRT) treatment increases the total integral dose of nontarget tissue relative to the conventional three-dimensional conformal radiotherapy (3D-CRT) technique for high-grade gliomas. Methods and Materials: Twenty patients treated with 3D-CRT for glioblastoma multiforme were selected for a comparative dosimetric evaluation with IMRT. Original target volumes, organs at risk (OAR), and dose-volume constraints were used for replanning with IMRT. Predicted isodose distributions, cumulative dose-volume histograms of target volumes and OAR, normal tissue integral dose, target coverage, dose conformity, and normal tissue sparing with 3D-CRT and IMRT planning were compared. Statistical analyses were performed to determine differences. Results: In all 20 patients, IMRT maintained equivalent target coverage, improved target conformity (conformity index [CI] 95% 1.52 vs. 1.38, p mean by 19.8% and D max by 10.7%), optic chiasm (D mean by 25.3% and D max by 22.6%), right optic nerve (D mean by 37.3% and D max by 28.5%), and left optic nerve (D mean by 40.6% and D max by 36.7%), p ≤ 0.01. This was achieved without increasing the total nontarget integral dose by greater than 0.5%. Overall, total integral dose was reduced by 7-10% with IMRT, p < 0.001, without significantly increasing the 0.5-5 Gy low-dose volume. Conclusions: These results indicate that IMRT treatment for high-grade gliomas allows for improved target conformity, better critical tissue sparing, and importantly does so without increasing integral dose and the volume of normal tissue exposed to low doses of radiation

  17. Caffeine prevents high-intensity exercise-induced increase in enzymatic antioxidant and Na+-K+-ATPase activities and reduction of anxiolytic like-behaviour in rats.

    Science.gov (United States)

    Vieira, Juliano M; Carvalho, Fabiano B; Gutierres, Jessié M; Soares, Mayara S P; Oliveira, Pathise S; Rubin, Maribel A; Morsch, Vera M; Schetinger, Maria Rosa; Spanevello, Roselia M

    2017-11-01

    Here we investigated the impact of chronic high-intensity interval training (HIIT) and caffeine consumption on the activities of Na + -K + -ATPase and enzymes of the antioxidant system, as well as anxiolytic-like behaviour in the rat brain. Animals were divided into groups: control, caffeine (4 mg/kg), caffeine (8 mg/kg), HIIT, HIIT plus caffeine (4 mg/kg) and HIIT plus caffeine (8 mg/kg). Rats were trained three times per week for 6 weeks, and caffeine was administered 30 minutes before training. We assessed the anxiolytic-like behaviour, Na + -K + -ATPase, superoxide dismutase (SOD), catalase (CAT), and glutathione peroxidase (GPx) activities, levels of reduced glutathione (GSH) and thiobarbituric acid reactive substances (TBARS) in the brain. HIIT-induced anxiolytic-like behaviour increased Na + -K + -ATPase and GPx activities and TBARS levels, altered the activities of SOD and CAT in different brain regions, and decreased GSH levels. Caffeine, however, elicited anxiogenic-like behaviour and blocked HIIT effects. The combination of caffeine and HIIT prevented the increase in SOD activity in the cerebral cortex and GPx activity in three brain regions. Our results show that caffeine promoted anxiogenic behaviour and prevented HIIT-induced changes in the antioxidant system and Na + -K + -ATPase activities.

  18. Delirium in the intensive care setting and the Richmond Agitation and Sedation Scale (RASS): Drowsiness increases the risk and is subthreshold for delirium.

    Science.gov (United States)

    Boettger, Soenke; Nuñez, David Garcia; Meyer, Rafael; Richter, André; Fernandez, Susana Franco; Rudiger, Alain; Schubert, Maria; Jenewein, Josef

    2017-12-01

    Sedation is a core concept in the intensive care setting, however, the impact of sedation on delirium has not yet been studied to date. In this prospective cohort study, 225 patients with Richmond Agitation and Sedation (RASS) scores of -1 - drowsiness and 0 - alert- and calmness were assessed with the Delirium Rating Scale-Revised 1998 (DRS-R-98) and DSM-IV-TR-determined diagnosis of delirium assessing drowsiness versus alertness. By itself, drowsiness increased the odds for developing delirium eightfold (OR 7.88 pmemory representing the core domains of delirium, or the temporal onset were very sensitive towards delirium, however lacked specificity. Conversely, delusions, perceptual abnormalities and lability of affect representing the non-core domain were very specific for delirium in the drowsy, however, not very sensitive. In the absence of delirium, drowsiness caused attentional impairment and language abnormalities. Drowsiness increased the odds for developing delirium eightfold and caused more severe delirium, which was characterized by sleep-wake cycle and language abnormalities. Further, drowsiness by itself caused attentional impairment and language abnormalities, thus, with its disturbance in consciousness was subthreshold for delirium. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Increased sensitivity in thick-target particle induced X-ray emission analyses using dry ashing for preconcentration

    International Nuclear Information System (INIS)

    Lill, J.-O.; Harju, L.; Saarela, K.-E.; Lindroos, A.; Heselius, S.-J.

    1999-01-01

    The sensitivity in thick-target particle induced X-ray emission (PIXE) analyses of biological materials can be enhanced by dry ashing. The gain depends mainly on the mass reduction factor and the composition of the residual ash. The enhancement factor was 7 for the certified reference material Pine Needles and the limits of detection (LODs) were below 0.2 μg/g for Zn, Cu, Rb and Sr. When ashing biological materials with low ash contents such as wood of pine or spruce (0.3% of dry weight) and honey (0.1% of wet weight) the gain was far greater. The LODs for these materials were 30 ng/g for wood and below 10 ng/g for honey. In addition, the ashed samples were more homogenous and more resistant to changes during the irradiation than the original biological samples. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  20. Evaluation of Effect of Gamma Rays Irradiation for Increasing of Variation in Germination and Agronomic Traits in Oilseed rape (Brassica napus L.

    Directory of Open Access Journals (Sweden)

    R. Momeni

    2012-04-01

    Full Text Available Increasing of genetic diversity is one of primary and basic goals of plant breeding programs. Induction of mutation is a method to increase genetic diversity that can be used in accommodate with selection, recombination and or combination of them in plant breeding. The aim of this study was to investigate the impact of different doses of gamma rays (500, 700, 900, 1100 and 1300 Gry on primary growth characters, such as: rate and percentage of germination, the length of rootlet and stemlet in M1 generation, and on agronomic characters such as: plant height, number of lateral branches, number of pods on main and lateral stem, length of pods and weigth of 1000-seed in M2 generation for two varieties of oilseed rape (Brassica napus, PF and Zarfam. Results of lab experiments showed that for both varieties, the germination percentage, the length of rootlet and the length of stemlet were significantly decreased by mutagen in compare with the control. While germination rate was only significantly affected by mutagen in PF. The estimation of "F" showed that there was significant difference between the variance of treatments for the germination rate and germination percentage in PF cultivar and for germination rate and stemlet length in Zarfam cultivar. In fact, increasing of gamma doses causes considerable enhancement in variance of treatment in compare with the control. The maximum relative coefficient of variation was related to 1300 Gry for germination rate of PF. In M2, all traits of study except number of pods on main stem was decreased by different doses of Gamma rays in PF cultivar. In opposition to other traits, Pods on main stem in PF cultivar was increased in different doses of gamma ray in compare with the control. But in Zarfam cultivar, only 1000-seed weight was significantly affected by Gamma rays.

  1. Extension of self-seeding to hard X-rays >10 keV as a way to increase user access at the European XFEL

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-11-01

    We propose to use the self-seeding scheme with single crystal monochromator at the European X-ray FEL to produce monochromatic, high-power radiation at 16 keV. Based on start to end simulations we show that the FEL power of the transform-limited pulses can reach about 100 GW by exploiting tapering in the tunable-gap baseline undulator. The combination of high photon energy, high peak power, and very narrow bandwidth opens a vast new range of applications, and includes the possibility to considerably increase the user capacity and fully exploit the high repetition rate of the European XFEL. In fact, dealing with monochromatic hard X-ray radiation one may use crystals as deflectors with minimum beam loss. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed for future study and possible extension of the baseline facility. They can be repeated a number of times to forman almost complete (one meter scale) ring with an angle of 20 degrees between two neighboring lines. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezo-electric devices similar to those for X-ray phase retarders at synchrotron radiation facilities. It is then possible to distribute monochromatic hard X-rays among 10 independent instruments, thereby enabling 10 users to work in parallel. The unmatched repetition rate of the European XFEL would be therefore fully exploited. (orig.)

  2. Extension of self-seeding to hard X-rays >10 keV as a way to increase user access at the European XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-11-15

    We propose to use the self-seeding scheme with single crystal monochromator at the European X-ray FEL to produce monochromatic, high-power radiation at 16 keV. Based on start to end simulations we show that the FEL power of the transform-limited pulses can reach about 100 GW by exploiting tapering in the tunable-gap baseline undulator. The combination of high photon energy, high peak power, and very narrow bandwidth opens a vast new range of applications, and includes the possibility to considerably increase the user capacity and fully exploit the high repetition rate of the European XFEL. In fact, dealing with monochromatic hard X-ray radiation one may use crystals as deflectors with minimum beam loss. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed for future study and possible extension of the baseline facility. They can be repeated a number of times to forman almost complete (one meter scale) ring with an angle of 20 degrees between two neighboring lines. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezo-electric devices similar to those for X-ray phase retarders at synchrotron radiation facilities. It is then possible to distribute monochromatic hard X-rays among 10 independent instruments, thereby enabling 10 users to work in parallel. The unmatched repetition rate of the European XFEL would be therefore fully exploited. (orig.)

  3. Chemo-radiotherapy for localized pancreatic cancer: increased dose intensity and reduced acute toxicity with concomitant radiotherapy and protracted venous infusion 5-fluorouracil

    International Nuclear Information System (INIS)

    Poen, Joseph C.; Collins, Helen L.; Niederhuber, John E.; Oberhelman, Harry A.; Vierra, Mark A.; Bastidas, Augusto J.; Young, Harvey S.; Slosberg, Edward A.; Jeffrey, Brooke R.; Longacre, Teri A.; Goffinet, Don R.

    1996-01-01

    intensity was significantly greater for the PVI treatment group. Cumulative 5-FU dose (mean = 7.1 gm/m 2 vs. 2.5 gm/m 2 , p 2 /wk vs. 0.5 gm/m2/wk, p < 0.001) were significantly higher in patients receiving PVI 5-FU. Following pancreaticoduodenectomy, 93% of those receiving PVI 5-FU were able to maintain a radiotherapy dose intensity of ≥ 900 cGy/wk throughout treatment, compared with 63% of those receiving bolus 5-FU (p = 0.03). No difference was seen for patients with locally advanced disease (67% vs. 76%, p = ns). Hematologic toxicity was reduced for patients receiving PVI 5-FU. Grade II-III neutropenia was less common for patients treated with PVI (10% vs. 34%, p = 0.04) compared with patients receiving bolus 5-FU. Thrombocytopenia was limited to Grade I in both treatment groups. Gastrointestinal toxicity as assessed by percent body weight loss during treatment was similar in the two treatment groups and was independent of disease stage. Mean percent weight loss for PVI and bolus 5-FU regimens were 4.7% and 4.1%, respectively (p = ns). Weight loss ≥ 5% body weight (32% vs. 31%) and ≥ 10% (10% vs. 7.7%, p = ns) were also similar between treatment groups. RT treatment interruptions for hematologic, gastrointestinal or other acute toxicities were less common for patients receiving PVI 5-FU (5% vs. 20%, p = 0.11) compared with patients receiving bolus 5-FU. Conclusion: Concurrent radiotherapy and protracted venous infusion 5-FU was well tolerated treatment for patients with localized pancreatic cancer and allowed for a 2.6 fold increase in 5-FU dose intensity for all patients, significantly greater radiotherapy dose intensity for res