  1. Calculation of gamma ray exposure rates from uranium ore bodies

    International Nuclear Information System (INIS)

    Thomson, J.E.; Wilson, O.J.

    1980-02-01

    The planning of operations associated with uranium mines often requires that estimates be made of the exposure rates from various ore bodies. A straight-forward method of calculating the exposure rate from an arbitrarily shaped body is presented. Parameters for the calculation are evaluated under the assumption of secular equilibrium of uranium with its daughters and that the uranium is uniformly distributed throughout an average soil mixture. The spectral distribution of the emitted gamma rays and the effect of air attenuation are discussed. Worked examples are given of typical situations encountered in uranium mines

  2. Design And Measurement Of Radiation Exposure Rates At An X-Ray Diagnostic Radiological Unit

    International Nuclear Information System (INIS)

    Tito-Sutjipto

    2003-01-01

    Every radiation employees suffers radiation exposure risk while doing his job. It is important therefore to investigate the occupational health and safety of radiation employees on its relationship with the design and measurement of radiation exposure rates at an X-ray diagnostic radiological unit in this work, a case study was held on the radiological unit at BP-4 Yogyakarta for patient diagnostics, This research armed to investigate the relationship between the design of radiological unit for X-ray diagnostics and the location of the X-ray machine, based on the distance variable and radiation exposure rate during patient diagnostics. This was performed using radiological unit design data for X-ray diagnostics and the measurement of radiation exposure rates throughout patient diagnostics. The design data can then be used for determining the requirement of primary and secondary shielding materials for radiological unit as well as a calculation basis of radiation exposure rates during patient diagnostics. From the result of the research, it can be concluded that from the occupational health and safety point of view, radiation exposure around the X-ray machines are fairly good, both for the shielding materials in each X-ray room and the radiation exposures received by the workers, because they are far beyond the maximum permittable average limit (16.67 m R/days). (author)

  3. Energy and rate dependence of diagnostic x-ray exposure meters

    International Nuclear Information System (INIS)

    Wagner, L.K.; Cerra, F.; Conway, B.; Fewell, T.R.; Ohlhaber, T.R.

    1988-01-01

    Variations in x-ray exposure measurements among a variety of contemporary diagnostic exposure meters are investigated. Variations may result from systematic errors due to calibration, beam-quality dependence and exposure-rate dependence. It is concluded that the majority of general purpose diagnostic meters will agree to within 10% of each other if exposure rates are below 1.3 mC kg-1S-1 of air (5 R s-1) and beam qualities are typical for general purpose radiology, excluding mammography. For exposure rates comparable to those in barium enema radiography the variations can range up to 25% or more. Variations up to 40% were observed among general purpose exposure meters at mammographic beam qualities. In the mammographic range, mammographic (thin window) exposure meters varied by no more than 2%

  4. Calculation on cosmic-ray muon exposure rate in non-walled concrete buildings

    International Nuclear Information System (INIS)

    Fujitaka, Kazunobu; Abe, Siro

    1984-01-01

    Computer simulations on the exposure indoors from cosmic ray muons were practiced in the framework of non-scattering and non-cascade assumptions. The model buildings were two-dimensional, rectangular, and were made of a normal concrete. A stratified structure was assumed in each building, where no mezzanine was considered. Walls were not taken into account yet. The distributions of the exposure rates in 26-story buildings were illustrated in contour maps for various sets of parameters. All of them gave basically archlike patterns. Analyses of the results showed that the exposure rate is affected most largely by the floor board thickness. The ceiling height would be an insignificant factor for short buildings. The min/max ratio of the muon exposure rate in a moderate size building was estimated to be more than 0.7. (author)

  5. Theoretical determination of spectrum-exposure rate conversion operator of HPGe detector and its application to the measurement of environmental gamma-ray exposure rate

    International Nuclear Information System (INIS)

    Park, Ch.M.; Choi, B.I.; Kwak, S.S.; Ji, P.K.; Kim, T.W.; Park, Y.W.; Yoon, B.K.

    1993-01-01

    A conversion operator between spectrum and exposure rate, using a portable HPGe detector for environmental radiation monitoring, was determined theoretically under the assumption of uniform distribution of radiation source on the ground surface. The measurement results were compared with those of a pressurized ionization chamber. The results obtained with the HPGe detector were slightly lower. The method can be easily applied to any gamma ray detector to obtain a spectrum - exposure-rate conversion factor for computing the exposure rate of environmental gamma radiation. (N.T.) 15 refs.; 6 figs.; 3 tabs

  6. Comparison of gamma-ray exposure rate measurements at Bikini Atoll

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Crites, T.R.

    1975-01-01

    A radiological survey of Bikini and Eneu Islands of the Bikini Atoll was conducted during June 1975 to assess the potential radiation doses that may be received by the returning Bikinians. Bikini Atoll was one of the U.S. nuclear weapons testing sites in the Pacific. An integral part of the survey included measurements of the gamma-ray exposure rates at 1 m above the ground with portable NaI instruments at nearly 2700 locations on the two islands. For comparison purposes, similar measurements were made with a pressurized ion chamber at approximately 200 locations, and with LiF and CaF 2 :Dy thermoluminescent dosimeters (TLDs) at 80 locations. The results indicate that the NaI scintillators overresponded because of their nonlinear energy characteristics. The responses of the LiF dosimeters and the pressurized ion chamber agreed to within 13 percent. Attenuation studies with LiF TLDs indicated that roughly 25 percent of the total free air exposure rate at 1 m was due to beta radiation

  7. Determination of gamma-ray exposure rate from short-lived fission products under criticality accident conditions

    International Nuclear Information System (INIS)

    Yanagisawa, Hiroshi; Ohno, Akio; Aizawa, Eijyu

    2002-01-01

    For the assessment of γ-ray doses from short-lived fission products (FPs) under criticality accident conditions, γ-ray exposure rates varying with time were experimentally determined in the Transient Experiment Critical Facility (TRACY). The data were obtained by reactivity insertion in the range of 1.50 to 2.93$. It was clarified from the experiments that the contribution of γ-ray from short-lived FPs to total exposure during the experiments was evaluated to be 15 to 17%. Hence, the contribution cannot be neglected for the assessment of γ-ray doses under criticality accident conditions. Computational analyses also indicated that γ-ray exposure rates from short-lived FPs calculated with the Monte Carlo code, MCNP4B, and photon sources based on the latest FP decay data, the JENDL FP Decay Data File 2000, well agreed with the experimental results. The exposure rates were, however, extremely underestimated when the photon sources were obtained by the ORIGEN2 code. The underestimation is due to lack of energy-dependent photon emission data for major short-lived FP nuclides in the photon database attached to the ORIGEN2 code. It was also confirmed that the underestimation arose in 1,000 or less of time lapse after an initial power burst. (author)

  8. X-ray equipment for dental diagnostics with a dose-rate controller influencing the exposure voltage

    International Nuclear Information System (INIS)

    Franke, K.

    1980-01-01

    If a synoptic picture is taken of teeth or jaw the X-ray tube and the film carrier with the film and a radiation detector are moving around the patient's head. The detector signal is connected to the input of the actual value of the dose-rate controller containing a scanning and stop circuit with a storing time roughly corresponding to the exposure of three teeth. After the shot the actual value of the dose rate is adjusted to the desired value, thus a constant quality of the following pictures being achieved. (RW) [de

  9. Comparative response of dogs and monkeys to sublethal acute and continuous low dose-rate gamma-ray exposure

    International Nuclear Information System (INIS)

    Spalding, J.F.; Holland, L.M.; Johnson, O.S.; LaBauve, P.M.; London, J.E.; Prine, J.R.; Vigil, E.A.

    1977-02-01

    Monkeys (Macaca mulatta) and dogs (beagle) were given thirteen 100-rad gamma-ray doses at 28-day intervals. The comparative response (injury and recovery) of the hematopoietic system of the two species was observed at 7-day intervals during the exposure regime. At 84 days after the thirteenth gamma-ray dose, the 1300-rad conditioned and control dogs and monkeys were challenged continuously with 35 R/day until death to determine the amount of radiation-induced injury remaining in conditioned animals as a reduction in mean survival time. Dogs (50 percent) and monkeys (8 percent) died from injury incurred during the conditioning exposures. Thus, the comparative response of dogs and monkeys to dose protraction by acute dose fractionation was similar to what might be expected from a single acute dose. Mean survival times for nonconditioned dogs and monkeys during continuous exposure at 35 R/day were the same (approximately 1400 h). Thus, hematopoietic response of the two species by this method of dose protraction was not significantly different. Mean survival times of conditioned dogs and monkeys during the continuous 35 R/day gamma-ray challenge exposure were greater than for their control counterparts. Thus, the long-term radiation-induced injury was not measurable by this method. Conditioning doses of more than four times the acute LD 50 - 30 in dogs and approximately two times that of monkeys served only to increase both mean survival time and variance in a gamma-ray stress environment with a dose rate of 35 R/day

  10. Measurement of the exposure rate due to low energy x-rays emitted from video display terminals

    International Nuclear Information System (INIS)

    Campos, L.L.

    1988-01-01

    Thermoluminescent dosimeters of CaSO 4 :Dy have been used to measure the low energy x-rays emitted from Video Display Terminals (VDTs). For each terminal, three points were measured with five dosimeters at each point. The points were at distances of 5 and 50 cm in front of the screen and at 65 cm with an angle of approximately 50 0 . The last two positions approximate to positions of the lenses of the eye and the gonads respectively. A survey of 50 VDTs at a distance of 5 cm from the screen resulted in exposure rates nearly fifteen times below the exposure rate of 0.5 mR h -1 (0.129 μC kg -1 h -1 ) which is the limit recommended by the International Atomic Energy Agency (IAEA), Safety Series No. 9 (1967) Basic Safety Standards for Radiation Protection. (author)

  11. Measurement and monitoring of entrance exposure dose rate in X-ray image intensifier television with dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J [Bezirkskrankenhaus Brandenburg (German Democratic Republic)

    1981-03-01

    For X-ray image intensifier television operation very low entrance dose rates (about 5.2 nA/kg) are stated and demanded, respectively. These required values are often manifold exceeded in practice so that a check seems to be necessary. It is shown and proved how these measurements can be performed with simple, generally available means of measurement in the radiological practice. For ZnCdS-image intensifiers should be considered that about 13 nA/kg for the large entrance size are not to be exceeded; for the CsI type lower values (factor 1.5) are practicable because of the twofold quantum absorption efficiency. Furthermore, some tests for a semiquantitative function check of the automatic dose rate control are proposed.

  12. Measurements and analyses of cosmic-ray exposure rates perturbed by various environmental objects

    International Nuclear Information System (INIS)

    Fukaya, Mitsuharu; Minato, Susumu

    1988-01-01

    One-dimensional intensity distributions of cosmic-rays transmitted through various large structural objects were measured to examine the feasibility of 'cosmic-ray radiography'. 1) For the rectungular building, (a) the bulk density estimation by comparison of the observed distribution with the calculated one, and (b) edge detection by differential method, were found to be possible. 2) For the stairs in the subway station, the relation between the intensities and the stairs depths was able to be interpreted by a simple model. These findings indicate that it is possible to correlate transmitted cosmic-ray intensity distributions to the structure and/or the physical quantities of large structural objects. (author)

  13. The rate of X-ray-induced DNA double-strand break repair in the embryonic mouse brain is unaffected by exposure to 50 Hz magnetic fields.

    Science.gov (United States)

    Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2015-06-01

    Following in utero exposure to low dose radiation (10-200 mGy), we recently observed a linear induction of DNA double-strand breaks (DSB) and activation of apoptosis in the embryonic neuronal stem/progenitor cell compartment. No significant induction of DSB or apoptosis was observed following exposure to magnetic fields (MF). In the present study, we exploited this in vivo system to examine whether exposure to MF before and after exposure to 100 mGy X-rays impacts upon DSB repair rates. 53BP1 foci were quantified following combined exposure to radiation and MF in the embryonic neuronal stem/progenitor cell compartment. Embryos were exposed in utero to 50 Hz MF at 300 μT for 3 h before and up to 9 h after exposure to 100 mGy X-rays. Controls included embryos exposed to MF or X-rays alone plus sham exposures. Exposure to MF before and after 100 mGy X-rays did not impact upon the rate of DSB repair in the embryonic neuronal stem cell compartment compared to repair rates following radiation exposure alone. We conclude that in this sensitive system MF do not exert any significant level of DNA damage and do not impede the repair of X-ray induced damage.

  14. Effect of continuous exposure to very low dose rates of gamma rays on life span and neoplasia in mice

    International Nuclear Information System (INIS)

    Tanaka, I.B. III; Tanaka, Satoshi; Ichinohe, Kazuaki; Matsumoto, Tsuneya; Otsu, Hiroshi; Oghiso, Yoichi; Sato, Fumiaki; Matsushita, Satoru

    2008-01-01

    Late effects of continuous exposure to ionizing radiation are potential hazards to workers in radiation facilities as well as to the general public. In the recent years, low-dose-rate and low-dose effects have become a serious concern. Using a total of 4,000 mice, we studied the late biological effects of chronic exposure to low-dose-rate radiation on life span and neoplasia. Two thousand male and 2000 female 8-week-old specific pathogen free (SPF) B6C3F1 mice were randomly divided into 4 groups, one non-irradiated (control) and three irradiated. The irradiated groups were exposed to 137 Cs gamma rays at dose-rates of 21, 1.1 and 0.05 mGy day -1 for approximately 400 days with total doses equivalent to 8000, 400 and 20 mGy, respectively. All mice were kept under SPF conditions until natural death and pathological examination was performed to determine the cause of death. Statistical analyses showed that the life spans of mice of both sexes irradiated with 21 mGy day -1 (P -1 (P 86.7% of all deaths. Compared to the non-irradiated controls, incidences of lethal neoplasms were significantly increased for myeloid leukaemia and hemangiosarcoma in males, soft tissue neoplasms and malignant granulosa cell tumors in females exposed to 21 mGy day -1 . The number of multiple primary neoplasms per mouse was significantly increased in mice irradiated at 21 mGy day -1 . Our results suggest that life shortening in mice continuously exposed to low dose-rate gamma rays is due to early death from a variety of neoplasms and not from increased incidence of specific lethal neoplasms. (author)

  15. γ-ray induced chromosome aberration in rabbit peripheral blood lymphocytes irradiated in partial and whole body and decline of aberration rate with time post-exposure

    International Nuclear Information System (INIS)

    Zhang Lianzhen; Deng Zhicheng; Wang Haiyan

    1997-01-01

    Te author presents the results of study on 60 Co γ-ray induced chromosome aberration in rabbits peripheral blood lymphocytes irradiated in partial and whole body and the aberration rate decrease with the time of post-exposure. The experiments included 5 groups, it was whole-body exposure group, partial-body exposure (abdomen and pelvic cavity) group, blood irradiation group in vitro and control group respectively. Radiation dose was 3.0 Gy delivered at rate of 0.5 Gy/min. The results show that it was no significant differences between whole body and in blood irradiation group. The chromosome aberration yield in whole body exposure group was higher than that in partial-body group and in the abdomen exposure group was higher than in that in the pelvic cavity irradiation; The chromosome aberration rate decreased with the time of post-exposure in partial and whole body by γ-ray irradiation

  16. Near-term and late biological effects of acute and low-dose-rate continuous gamma-ray exposure in dogs and monkeys

    International Nuclear Information System (INIS)

    Spalding, J.F.; Holland, L.M.

    1979-07-01

    Monkeys (Macaca mulatta) and dogs (beagle) were given thirteen 100-rad gamma-ray doses at 28-day intervals. The comparative response (inury and recovery) of the hematopoietic system of the two species was observed at 7-day intervals during the exposure regime. At 84 days after the thirteenth gamma-ray dose, the 1300-rad conditioned and control dogs and monkeys were challenged continuously with gamma rays at 35 r/day until death to determine the amount of radiation-induced injry remaining in conditioned animals as a reduction in mean survival time. Dogs (50%) and monkeys (8%) died from injury incurred during conditioning exposures. Thus, the comparative response (in terms of lethality) of dogs and monkeys to dose protraction by acute dose fractionation was similar to what we would expect from a single acute dose. The mean survival times for nonconditioned dogs and monkeys during continuous exposure at 35 R/day were the same (approx. 1400 h). Thus, the hematopoietic response of the two species by this method of dose protraction was not significantly different. Mean survival times of conditioned dogs and monkeys during the continuous 35-R/day gamma-ray challenge exposure were greater (significant in dogs but not in monkeys) than for their control counterparts. Thus, long-term radiation-induced injury was not measurable by this method. Conditioning doses of more than 4 times the acute LD 50 30 in dogs and approximately 2 times that in monkeys served only to increase both mean survival time and variance in a gamma-ray stress environment with a dose rate of 35 Rat/day

  17. Cosmic-ray exposure records and origins of meteorites

    International Nuclear Information System (INIS)

    Reedy, R.C.

    1985-01-01

    The cosmic-ray records of meteorites can be used to infer much about their origins and recent histories. Some meteorites had simple cosmic-ray exposure histories, while others had complex exposure histories with their cosmogenic products made both before and after a collision in space. The methods used to interpret meteorites' cosmic-ray records, especially identifying simple or complex exposure histories, often are inadequate. Besides spallogenic radionuclides and stable nuclides, measurements of products that have location-sensitive production rates, such as the tracks of heavy cosmic-ray nuclei or neutron-capture nuclides, are very useful in accurately determining a meteorite's history. Samples from different, known locations of a meteorite help in studying the cosmic-ray record. Such extensive sets of meteorite measurements, plus theoretical modeling of complex histories, will improve our ability to predict the production of cosmogenic nuclides in meteorites, to distinguish simple and complex exposure histories, and to better determine exposure ages

  18. A paediatric X-ray exposure chart

    Energy Technology Data Exchange (ETDEWEB)

    Knight, Stephen P, E-mail: stephen.knight@health.qld.gov.au [Department of Medical Imaging, Royal Children' s Hospital, Brisbane, Queensland (Australia)

    2014-09-15

    The aim of this review was to develop a radiographic optimisation strategy to make use of digital radiography (DR) and needle phosphor computerised radiography (CR) detectors, in order to lower radiation dose and improve image quality for paediatrics. This review was based on evidence-based practice, of which a component was a review of the relevant literature. The resulting exposure chart was developed with two distinct groups of exposure optimisation strategies – body exposures (for head, trunk, humerus, femur) and distal extremity exposures (elbow to finger, knee to toe). Exposure variables manipulated included kilovoltage peak (kVp), target detector exposure and milli-ampere-seconds (mAs), automatic exposure control (AEC), additional beam filtration, and use of antiscatter grid. Mean dose area product (DAP) reductions of up to 83% for anterior–posterior (AP)/posterior–anterior (PA) abdomen projections were recorded postoptimisation due to manipulation of multiple-exposure variables. For body exposures, the target EI and detector exposure, and thus the required mAs were typically 20% less postoptimisation. Image quality for some distal extremity exposures was improved by lowering kVp and increasing mAs around constant entrance skin dose. It is recommended that purchasing digital X-ray equipment with high detective quantum efficiency detectors, and then optimising the exposure chart for use with these detectors is of high importance for sites performing paediatric imaging. Multiple-exposure variables may need to be manipulated to achieve optimal outcomes.

  19. Cosmic-ray exposure records and origins of meteorites

    International Nuclear Information System (INIS)

    Reedy, R.C.

    1985-01-01

    The cosmic-ray records of meteorites are used to infer much about their origins and recent histories. The methods used to interpret meteorites cosmic-ray records, especially identifying simple or complex exposure histories, often are inadequate. Spallogenic radionuclides, stable nuclides, and measurements of products that have location-sensitive production rates, such as the tracks of heavy cosmic-ray nuclei or neutron-capture nuclides, are very useful in accurately determining a meteorite's history. Samples from different, known locations of a meteorite help in studying the cosmic-ray record. Such extensive sets of meteorite measuremetns, plus theoretical modeling of complex histories, improves the ability to predict the production of cosmogenic nuclides in meteorites, to distinguish simple and complex exposure histories, and to better determine exposure ages

  20. X-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients and a skeleton encased in plastic were instrumented with LiF thermoluminescent dosimeters to determine radiation exposures delivered from full-face diagnostic dental X-rays. Measurements were made using various panoramic radiographical and periapical machines. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices. (author)

  1. The rate of repeating X-rays in the medical centers of Jenin District/Palestine and how to reduce patient exposure to radiation

    Science.gov (United States)

    Assi, Abed Al Nasser

    2018-03-01

    Reduction of the patient's received radiation dose to as low as reasonably achievable (ALARA) is based on recommendations of radiation protection organizations such as the International Commission on Radiological Protection (ICRP) and the National Radiological Protection Board (NRPB). The aim of this study was to explore the frequency and characteristics of rejected / repeated radiographic films in governmental and private centers in Jenin city. The radiological centers were chosen based on their high volume of radiographic studies. The evaluation was carried out over a period of four months. The collected data were compiled at the end of each week and entered into a computer for analysis at the end of study. Overall 5000 films (images) were performed in four months, The average repeat rate of radiographic images was 10% (500 films). Repetition rate was the same for both thoracic and abdominal images (42%). The main reason for repeating imaging was inadequate imaging quality (58.2%) and poor film processing (38%). Human error was the most likely reason necessitating the repetition of the radiographs (48 %). Infant and children groups comprised 85% of the patient population that required repetition of the radiographic studies. In conclusion, we have a higher repetition rate of imaging studies compared to the international standards (10% vs. 4-6%, respectively). This is especially noticeable in infants and children, and mainly attributed to human error in obtaining and processing images. This is an important issue that needs to be addressed on a national level due to the ill effects associated with excessive exposure to radiation especially in children, and to reduce cost of the care delivered.

  2. The foreign exchange rate rate exposure of nations

    OpenAIRE

    Entorf, Horst; Moebert, Jochen; Sonderhof, Katja

    2007-01-01

    Following the well-known approach by Adler and Dumas (1984) we evaluate the foreign exchange rate exposure of nations. Results based on data from 27 countries show that national foreign exchange rate exposures are significantly related to the current trade balance variables of corresponding economies.

  3. The Foreign Exchange Rate Exposure of Nations

    OpenAIRE

    Entorf, Horst; Moebert, Jochen; Sonderhof, Katja

    2007-01-01

    Following the well-known approach by Adler and Dumas (1984), we evaluate the foreign exchange rate exposure of nations. Results based on data from 27 countries show that national foreign exchange rate exposures are significantly related to the current trade balance variables of corresponding economies.

  4. Low dose rate gamma ray induced loss and data error rate of multimode silica fibre links

    International Nuclear Information System (INIS)

    Breuze, G.; Fanet, H.; Serre, J.

    1993-01-01

    Fiber optics data transmission from numerous multiplexed sensors, is potentially attractive for nuclear plant applications. Multimode silica fiber behaviour during steady state gamma ray exposure is studied as a joint programme between LETI CE/SACLAY and EDF Renardieres: transmitted optical power and bit error rate have been measured on a 100 m optical fiber

  5. THIDA: code system for calculation of the exposure dose rate around a fusion device

    International Nuclear Information System (INIS)

    Iida, Hiromasa; Igarashi, Masahito.

    1978-12-01

    A code system THIDA has been developed for calculation of the exposure dose rates around a fusion device. It consists of the following: one- and two-dimensional discrete ordinate transport codes; induced activity calculation code; activation chain, activation cross section, radionuclide gamma-ray energy/intensity and gamma-ray group constant files; and gamma ray flux to exposure dose rate conversion coefficients. (author)

  6. Accidental exposure with X-ray diffraction equipment

    International Nuclear Information System (INIS)

    Montanez, O.; Blanco, D.

    1991-01-01

    The shutter on one of the windows of an X-ray diffraction apparatus was accidentally left open, exposing the worker to the radiation. The worker was wearing a dosimeter film, which was processed immediately to evaluate the potential risk. It was determined that the exposure rate was 350 Roentgen/minute on the skin surface, with corrections being made for the worker's thin clothing. It was concluded that in spite of the worker receiving a relative high dose, it did not reach the threshold value for producing deterministic effects such as cataracts, erythema, and skin damage

  7. Cancer incidence rate after diagnostic X-ray exposure in 1976-2003 among patients of a university children's hospital; Inzidenz von Kinderkrebs nach Roentgendiagnostik im Patientenkollektiv der Jahre 1976-2003 einer Universitaets-Kinderklinik

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, G.P.; Zeeb, H.; Blettner, M. [Mainz Univ. (DE). Inst. fuer Medizinische Biometrie, Epidemiologie und Informatik (IMBEI); Seidenbusch, M.C.; Schneider, K. [Klinikum der Univ. Muenchen, Dr. von Haunersches Kinderspital (Germany). Abt. Radiologie; Regulla, D. [Helmholtz Zentrum Muenchen - Deutsches Forschungszentrum fuer Gesundheit und Umwelt, Neuherberg (Germany). Inst. fuer Strahlenschutz; Spix, C. [Mainz Univ. (Germany). Deutsches Kinderkrebsregister

    2010-05-15

    Purpose: Although the carcinogenic effect of ionizing radiation is well known, knowledge gaps persist on the health effects of low-dose radiation, especially in children. The cancer incidence rate in a cohort of 92,957 children diagnosed using X-rays in the years 1976-2003 in the radiology department of a large university clinic was studied. Materials and Methods: Individual radiation doses per examination were reconstructed using an algorithm taking into account the dose area product and other exposure parameters together with conversion factors computed specifically for the equipment and protocols used in the radiology department. Incident cancer cases in the period 1980-2006 were identified via record linkage to the German Childhood Cancer Registry using pseudonymized data. Results: A total of 87 cancers occurred in the cohort between 1980 and 2006: 33 leukemia, 13 lymphoma, 10 brain tumors, and 31 other tumors. The standardized incidence ratio (SIR) for all cancers was 0.99 (95 % CI: 0.79 1.22). A dose-response relationship was not observed for all cancers, leukemia and lymphoma or solid tumors. The cancer risks for boys and girls did not differ. Conclusion: No increase in the cancer incidence risk in relation to very low doses of diagnostic ionizing radiation was observed in this study. However, the results are compatible with a broad range of risk estimates. (orig.)

  8. Contribution of cosmic rays to radiation exposure of the population

    International Nuclear Information System (INIS)

    Sztanyik, L.B.; Nikl, I.

    1982-01-01

    To evaluate the exposure of the Hungarian population to cosmic rays, the absorbed dose rate in air of cosmic radiation was directly measured by high pressure ionization chamber at ground level on the surface of different bodies of water and at various altitudes on the board of an aircraft. From the dose rates measured this way, the outdoor dose equivalent rate from the ionizing components of cosmic radiation to people living at sea level would be 300-325 μSv per year. Taking into account the altitude distribution of the population, the average weighted dose equivalent is about 320 μSv per year. At Kekestetoe, the highest peak of the Matra Mountains, (the highest altitude in Hungary), the annual dose equivalent is about 50 per cent higher than on the Great Hungarian Plain. (author)

  9. High exposure rate hardware ALARA plan

    International Nuclear Information System (INIS)

    Nellesen, A.L.

    1996-10-01

    This as low as reasonably achievable review provides a description of the engineering and administrative controls used to manage personnel exposure and to control contamination levels and airborne radioactivity concentrations. HERH waste is hardware found in the N-Fuel Storage Basin, which has a contact dose rate greater than 1 R/hr and used filters. This waste will be collected in the fuel baskets at various locations in the basins

  10. γ-ray dose rate effect in DNA double-strand break repair deficient murine cells

    International Nuclear Information System (INIS)

    Li Liya; Li Peiwen

    2002-01-01

    Objective: To analyze the dose rate effect and potentially lethal damage repair in DNA double-strand break repair deficient murine cells (SCID) irradiated by γ-ray. Methods: The wild type (CB.17+/+) and SCID cells were exposed to γ-ray at high and low dose rates. The high dose rate exposure was fractionated into two equal doses at 24 h intervals. The survival rates of irradiated cells were calculated by clone-forming analysis. Results: When γ-ray was given to wild type (CB.17+/+) cells in two fractions at 24 h intervals, the survival rate was significantly higher than that when the same total dose was given singly. In contrast, there was no difference in the survival rates between the single and fractionated exposure in SCID cells. SCID cells were more sensitive than CB.17+/+ cells to both low and high dose rates γ-ray exposure for cell killing. The survival rate by low dose rate exposure was significantly higher than that by high dose rate exposure, not only in CB.17+/+ cells but also in SCID cells. Conclusions: SCID cells are deficient in repairing γ-ray induced double-strand breaks. There is dose rate effect in both SCID and CB.17+/+ cells

  11. Preparation of exposures charts for X-ray tubes

    International Nuclear Information System (INIS)

    Zoofan, B.

    1988-01-01

    An exposure chart is a fundamental graph which provides guidance of the exposure conditions in relation to the thickness for a given specimen. It must be prepared specially for the X-ray unit and the type of the film to be used. Although exposure charts are available for each particular X-ray tube from its manufacturer, individual radiographic laboratory should be able to prepare its own exposure charts in a precise manner. Here a typical procedure to prepare such a chart is provided in a practical way with some necessary recommendations

  12. Trends in x-ray photography and patient exposure dose

    International Nuclear Information System (INIS)

    Orito, Takeo; Sanada, Shigeru; Maekawa, Ryuichi; Koshida, Kichiro; Hiraki, Tatsunosuke

    1980-01-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired. (J.P.N.)

  13. Measurements of indoor and outdoor natural radiation exposure rates in model houses

    International Nuclear Information System (INIS)

    Matsuda, Hideharu; Fukaya, Mitsuharu; Minato, Susumu

    1990-01-01

    Natural gamma-ray and cosmic-ray exposure rates were measured indoors and outdoors for 94 model houses of four housing centers in Nagoya to obtain basic data for estimation of the population dose. Influence of the structure of houses on indoor exposure rates and relationship between indoor and outdoor natural gamma-ray exposure rates were studied. Exposure rates were measured with a 1.5'' φ x 4'' NaI (Tl) scintillation counter and a 6''φ spherical plastic scintillation counter. The mean indoor natural gamma-ray exposure rate in ferro-concrete buildings was about 40% higher than that in fireproof wooden houses, about 60% higher than that in light-weight steel-framed buildings, in fireproof wooden houses, it was also about 10% higher than in light-weight steel-framed building. The ratio of indoor to outdoor natural gamma-ray exposure rate was found to be about 0.95±0.15, 0.77±0.10, and 0.72±0.13 for ferro-concrete buildings, fireproof wooden houses and light-weight steel-framed buildings, respectively. The mean indoor cosmic-ray exposure rate in ferro-concrete buildings was 2.8 μR/h, about 18% lower than the outdoors. The indoor cosmic-ray exposure rate in fireproof wooden houses and light-weight steel-framed buildings were 3.2 μR/h, about 6% lower than the outdoors. (author)

  14. Measurements of natural radiation exposure rates in various living environment, (2)

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1991-01-01

    Natural gamma-ray and cosmic-ray exposure rates were measured indoors and outdoors for 94 model houses of housing exhibition centers in Nagoya to obtain basic data for estimation of the population dose. Influence of the structure of houses on indoor exposure rates and relationship between indoor and outdoor natural gamma-ray exposure rates were studied. Exposure rates were measured with a 1.5''φ x 4''NaI(Tl) scintillation counter and a 6''φ spherical plastic scintillation counter. The mean indoor natural gamma-ray exposure rate in ferro-concrete buildings was about 40 % higher than that in fire-proof wooden houses and about 60 % higher than that in light weight steel framed buildings; that in fire-proof wooden houses was about 10 % higher than that in light weight steel framed buildings. The ratio of indoor to outdoor natural gamma-ray exposure rate was found to be 0.95 ± 0.15, 0.77 ± 0.10 and 0.72 ± 0.13 for ferro-concrete buildings, fire-proof wooden houses and light weight steel framed buildings, respectively. The mean indoor cosmic-ray exposure rate in ferro-concrete buildings was 2.8 μR/h, which was about 18 % lower than the outdoor value. The indoor cosmic-ray exposure rate both in fire-proof wooden houses and in light weight steel framed buildings were about 3.2 μR/h, which was 6 % lower than the outdoor value. (author)

  15. Exposure of nitrous oxide to X-rays

    International Nuclear Information System (INIS)

    Yanagida, H.

    1980-01-01

    A study was performed to determine how much NO and NO 2 is produced when nitrous oxide is exposed to X-radiation. Polyethylene bottles filled with either nitrous oxide alone or with nitrous oxide and 30% oxygen were placed 30 cm from the X-ray tube at a standard X-ray beam setting for chest fluoroscopy for 0 to 5 minutes. In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray exposure, this study suggests another potentially hazardous interaction that may occur secondary to the administration of an anaesthetic in the presence of X-irradiation as in pulmonary angiography, cardiac catheterisation, and fluoroscopic bronchoscopy or biopsy. (author)

  16. Exposure-rate calibration using large-area calibration pads

    International Nuclear Information System (INIS)

    Novak, E.F.

    1988-09-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. A set of large-area, radioelement-enriched concrete pads was constructed by the DOE in 1978 at the Walker Field Airport in Grand Junction for use as calibration standards for airborne gamma-ray spectrometer systems. The use of these pads was investigated by the TMC as potential calibration standards for portable scintillometers employed in measuring gamma-ray exposure rates at Uranium Mill Tailings Remedial Action (UMTRA) project sites. Data acquired on the pads using a pressurized ionization chamber (PIC) and three scintillometers are presented as an illustration of an instrumental calibration. Conclusions and recommended calibration procedures are discussed, based on the results of these data

  17. AIRGAMMA, External Gamma-Ray Exposure from Radioactive Cloud

    International Nuclear Information System (INIS)

    Hidaka, Akihide; Iijima, Tshinori

    1989-01-01

    1 - Description of program or function: AIRGAMMA calculates quickly the external exposure to gamma rays from a radioactive cloud. 2 - Method of solution: The external exposure is calculated by interpolating the normalized doses providing on the basis of the Gaussian plume model. 3 - Restrictions on the complexity of the problem: Memory requirement is 30 Kbytes

  18. Nitrous oxide pollution during x-ray exposure

    International Nuclear Information System (INIS)

    Yanagida, Hisashi; Nakajima, Michiaki.

    1980-01-01

    X-radiation has been shown to produce NO and NO 2 in the presence of nitrous oxide. The purpose of the present study was to confirm how much NO and NO 2 was produced when constant amount of nitrous oxide was exposed by constant X-radiation. Twenty polyethylene bottles (capacity 10 litres) were filled with nitrous oxide alone. Another 20 bottles were filled with nitrous oxide and 30% oxygen. Each bottle was placed at a distance of 30 cm from X-ray tube and they were directly in the line of the X-ray beam at a setting of 90 KV at 0.5 mA, a standard setting for chest fluoroscopy. The range of duration of X-ray exposure was from 0 (control), to 2, 3, and 5 minutes in 5 bottles each, respectively. A colorimetric recording method (Saltzman) and a chemiluminescent monitor were used for measurement of NO and NO 2 . In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray, this study suggests another potentially hazardous interaction that may occur secondary to the administration of anesthetic in the presence of X-irradiation such as pulmonary angiography, cardiac catheterization, and fluoroscopic bronchoscopy or biopsy under general anesthesia. (author)

  19. Does Interest rate Exposure explain the Low-Volatility Anomaly?

    NARCIS (Netherlands)

    Driessen, Joost; Kuiper, Ivo; Beilo, R.

    We show that part of the outperformance of low-volatility stocks can be explained by a premium for interest rate exposure. Low-volatility stock portfolios have negative exposure to interest rates, whereas the more volatile stocks have positive exposure. Incorporating an interest rate premium

  20. Measurements of national radiation exposure rates on train lines in Tokai area

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1996-01-01

    For data accumulation of natural radiation exposure rate derived from gamma-ray and cosmic-ray to evaluate population dose, the author measured the rate in the running vehicles of 12 JR Tokai lines, 17 Nagoya Railway lines, 4 Kinkinippon Railway lines and 1 line of Nagoya City Bus. A portable gamma spectrometer equipped with 3' in diameter x 3' NaI (Tl) scintillation detector was placed on the seat of the vehicle for measurement in the period of December, 1992-August, 1995. Gamma-ray and cosmic-ray exposure rates in air were assessed separately as reported before and expressed in Gy/h. The average exposure rate of gamma-ray in JR Tokai lines was 19.8 nGy/h and of cosmic-ray, 28.5 nGy/h, both of which were markedly varied from line to line. The average rates of gamma-and cosmic-ray were 21.6 nGy/h and 29.0 nGy/h, respectively, in Nagoya Railway lines and 20.9 nGy/h and 28.7 nGy/h, respectively, in Kinkinippon lines. In the city bus, the respective rates were 27.2 nGy/h and 27.0 nGy/h. Thus, the average rates of gamma-ray (about 20 nGy/h) and cosmic-ray (about 29 nGy/h) were not so different between JR and other private railway lines. In the bus, the former rate was slightly lower and the latter, slightly higher. However, the total rates of both rays were in the range of about 50-55 nGy/h in all vehicles examined. (H.O.)

  1. X-ray exposure from colour TV sets

    International Nuclear Information System (INIS)

    Nambi, K.S.V.; Viswanathan, P.S.

    1988-01-01

    A survey has been made of the X-ray exposures from colour television sets of eight different brands manufactured in India and one of foreign make. The high sensitivity of natural CaF 2 TL phosphor to low energy photons has been taken advantage of, in measuring the extremely low levels of the X-ray emis sion from the TV sets. The measured exposures range from 8 to 27 μRh -1 and are well below the radiation safety limit internationally adopted. (author). 4 tabs

  2. Excessive exposures of diagnostic X-ray workers in India

    International Nuclear Information System (INIS)

    Ambiger, T.Y.; Shenoy, K.S.; Patel, P.H.

    1980-01-01

    The excessive exposures (i.e. exceeding 400 mrems per fortnight) of diagnostic X-ray workers revealed under the countrywide personnel monitoring programme in India have been analysed. The analysis covers the data collected over a period of ten years during 1965-1974. The radiation workers in medical X-ray diagnostic group receiving an excess dose are found to be less than 1%. Each case of the excess dose is throughly investigated and nongenuine cases are separated and causes for genuine excessive exposures are traced. The causes and the corrective measures are enumerated. (M.G.B.)

  3. Cosmic ray exposure in aircraft and space flight

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Sugiura, Nobuyuki; Iimoto, Takeshi

    2000-01-01

    The exposure from cosmic ray radiation to the workers and public is a new aspect of exposure that was cased by the development of science and technology. ICRP Publication 60 says: 'to provide some practical guidance, the Commission recommends that there should be a requirement to include exposure to natural sources as part of occupational exposure only in the following cases: radon..., some natural radionuclides..., operation of jet air craft, space flight'. For this situation what kind of radiation protection concept is applicable? And what kind of radiation guideline and procedure are possible to propose? Here, we would like to review the past activities on this issue and to summarize the concepts in ICRP concerning to these exposure. Then the recommended radiation protection system will be proposed as one trial to this solution. In the paper the characters of cosmic ray were firstly reviewed. Cosmic rays are consisted by solar one and galactic one. Both of them have high energy and this will cause the difficulty of dosimetry because of lacking of physical and biological data. Next discussion point is a classification of exposure. For this, several classifications were done: jet airplane flight, supersonic airplane flight and space flight. Other classification is aircrew (occupational exposure), passengers (public exposure), frequent flyers (gray zone), space astronauts (special mission), and pregnant women. Considering the real level of radiation the practical radiation control is proposed including the cosmic radiation exposure prediction method by computer codes. The discussion of space astronauts is a little different for the highness of radiation doses. The dose levels will be obtained through the discussion of lifetime risk balancing their mission importance. (author)

  4. In situ measurements of dose rates from terrestrial gamma rays

    International Nuclear Information System (INIS)

    Horng, M.C.; Jiang, S.H.

    2002-01-01

    A portable, high purity germanium (HPGe) detector was employed for the performance of in situ measurements of radionuclide activity concentrations in the ground in Taiwan, at altitudes ranging from sea level to 3900 m. The absolute peak efficiency of the HPGe detector for a gamma-ray source uniformly distributed in the semi-infinite ground was determined using a semi-empirical method. The gamma-ray dose rates from terrestrial radionuclides were calculated from the measured activity levels using recently published dose rate conversion factors. The absorbed dose rate in air due to cosmic rays was derived by subtracting the terrestrial gamma-ray dose rate from the overall absorbed dose rate in air measured using a high-pressure ionization chamber. The cosmic-ray dose rate calculated as a function of altitude, was found to be in good agreement with the data reported by UNSCEAR. (orig.)

  5. Accidental over-exposure from dental X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, B G [National Radiological Protection Board, Harwell (UK)

    1976-07-01

    A description is given of an unusual dental X-ray procedure which resulted in accidental over-exposure both to the dentist and to several of his patients when a short-circuit was present in newly-installed equipment. The short-circuit by-passed the exposure control and energized the tube for certain orientations of the X-ray tube. The dentist left the patients, who wore protective aprons, to initiate the exposure themselves, using the control button. Although the warning lights were on, the dentist was not present in the room during the exposure, and the over-exposures were only detected when the developed X-ray films were found to be completely blackened. A reconstruction of the procedure enabled estimates to be made of the dose equivalents to the dentist's body and to the skin of the head, the eyes and the gonads of the patients. The dentist had overlooked several of basic principles recommended in the Code of Practice for the Protection of Persons against Ionizing Radiations from Medical and Dental Use (1972). It is pointed out that incidents involving failure of dental equipment (usually the timer mechanism) are not infrequent.

  6. Cosmic-ray-produced stable nuclides: various production rates and their implications

    International Nuclear Information System (INIS)

    Reedy, R.C.

    1981-01-01

    The rates for a number of reactions producing certain stable nuclides, such as 3 He and 4 He, and fission in the moon are calculated for galactic-cosmic-ray particles and for solar protons. Solar-proton-induced reactions with bromine usually are not an important source of cosmogenic Kr isotopes. The 130 Ba(n,p) reaction cannot account for the undercalculation of 130 Xe production rates. Calculated production rates of 15 N, 13 C, and 2 H agree fairly well with rates inferred from measured excesses of these isotopes in samples with long exposure ages. Cosmic-ray-induced fission of U and Th can produce significant amounts of fission tracks and of 86 Kr, 134 Xe, and 136 Xe, especially in samples with long exposures to cosmic-ray particles

  7. Exposure to rays and radiation hazards in connection with diagnostic X-ray procedures in children

    International Nuclear Information System (INIS)

    Protzer, K.

    1988-01-01

    In this study, figures and data about radiation exposures for diagnostic purposes are surveyed that were collected in connection with X-ray procedures in children. The data were sorted according to body regions and techniques required for their examination so as to permit separate analyses of procedures in the urogenital tract (intravenous urogramme, micturition cystourethrography), thorax (angiocardiogramme, thoractic aortogramme, examinations using cardiac catheters), gastrointestinal system (fluoroscopy and contrast-enhanced irrigoscopy), pelvis (survey radiography), skull (computed tomography) as well as in miscellaneous group of further origins. The second part of the report discusses the uncertainties surrounding the assessment of radiation hazards and indicated radiation doses. A formula is represented for the calculation of life-time reductions that can be applied to any type of cancer and embraces a number of factors like life expectancy at age X, the patient's age at the time of radiotherapy, the five-year-survival rate for the condition under investigation and the diseased organ. At the end of the study, some methods are pointed out that may be helpful in limiting radiation exposure. (KST) [de

  8. The Exchange Rate Exposure of Danish Non-Financial Companies

    DEFF Research Database (Denmark)

    Aabo, Tom

    1999-01-01

    of the extra-market exchange rate exposure of individual companies. As such, only a minority of companies has significant exposures when using the effective Danish exchange rate in an OLS regression analysis while half of the companies have significant exposures when using five main exchange rates. A GARCH(1......A shortcut to measuring exchange rate exposure at the company level can be to exploit the information content in the stock prices. A regression analysis is conducted for the main Danish non-financial companies. The use of one all-comprising exchange rate indicator fails to address the complexity......,1) regression analysis is shown to further improve the detection of exposures. The success in identifying exposures for Danish non-financial companies is in contrast to earlier US studies and is relevant in a European context....

  9. Constancy of radiation output during diagnostic X-ray exposures

    International Nuclear Information System (INIS)

    Ardran, G.M.; Crooks, H.E.; Birch, R.

    1978-01-01

    Variation in X-ray output and quality during a diagnostic exposure can be undesirable and may result in unnecessary dose to the patient. When significant build-up or decay periods are present errors will arise if factors obtained under steady-state conditions are employed to estimate the exposure. These parameters must be taken into account when calibrating X-ray generators. A variable speed spinning film device and a spectrometry system have been used to measure the variations under fluoroscopic and radiographic conditions for a number of generators. Variations in output due to filament heating, voltage supply and rectification, cable capacity and target pitting have been demonstrated. At low fluoroscopic currents, large surges and long decays have been observed; the significance of these effects is considered. (author)

  10. Radiation exposure in X-ray studies of the hips

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F [Krankenhaus der Barmherzigen Brueder, Salzburg (Austria). Roentgeninstitut

    1979-12-01

    The genetic exposure of the small child is above all a consequence of the rapid increase in X-ray studies, a problem which has not yet been settled. Through phantom measurements it can be shown, that dose reduction is of considerable practical significance if appropriate lead shielding is employed. The radiation dose can be significantly reduced, provided that the shielding material is of an appropriate lead equivalent. The form of the pelvic shield which is used is also of crucial importance.

  11. Prenatal x-ray exposure and childhood cancer in twins

    International Nuclear Information System (INIS)

    Harvey, E.B.; Boice, J.D. Jr.; Honeyman, M.; Flannery, J.T.

    1985-01-01

    A case-control study was conducted to investigate the relation between prenatal exposure to x-rays and childhood cancer, including leukemia, in over 32,000 twins born in Connecticut from 1930 to 1969. Twins as opposed to single births were chosen for study to reduce the likelihood of medical selection bias, since twins were often exposed to x-rays to diagnose the twin pregnancy or to determine fetal positioning before delivery and not because of medical conditions that may conceivably pre-dispose to cancer. Each of 31 incident cases of cancer, identified by linking the Connecticut twin and tumor registries, was matched with four twin controls according to sex, year of birth, and race. Records of hospitals, radiologists, and private physicians were searched for histories of x-ray exposure and other potentially important risk factors. Documented prenatal x-ray exposures were found for 39 per cent of the cases (12 of 31) and for 26 per cent of the controls (28 of 109). No other pregnancy, delivery, or maternal conditions were associated with cancer risk except low birth weight: 38 per cent of the cases as compared with 25 per cent of the controls weighed under 2.27 kg at birth. When birth weight was adjusted for, twins in whom leukemia or other childhood cancer developed were twice as likely to have been exposed to x-rays in utero as twins who were free of disease (relative risk, 2.4; 95 per cent confidence interval, 1.0 to 5.9). The results, though based on small numbers, provide further evidence that low-dose prenatal irradiation may increase the risk of childhood cancer

  12. Determination of x-radiation exposure rates from color television sets

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.

    1988-05-01

    The exposure rates of low energy X-rays emitted from color televisions were determined by thermoluminescence using CaSO 4 :Dy + Teflon pellets. The measurements were taken at the distances of 5 cm, 2 and 3 m in front of the screens. The results were compared with those obtained for video display terminals at the same experimental conditions. (author) [pt

  13. Dose Rate Determination from Airborne Gamma-ray Spectra

    DEFF Research Database (Denmark)

    Bargholz, Kim

    1996-01-01

    The standard method for determination of ground level dose rates from airborne gamma-ray is the integral count rate which for a constant flying altitude is assumed proportional to the dose rate. The method gives reasonably results for natural radioactivity which almost always has the same energy...

  14. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  15. Acute behavioural dysfunctions following exposure to γ-rays

    International Nuclear Information System (INIS)

    Kumar, Mayank; Haridas, Seenu; Manda, Kailash

    2014-01-01

    Exposure to ionizing radiations (IR) has been reported to have many ill effects. These are manifested immediately after exposure and may persist or develop long after the incident. The severity and manifestation is dependent on the absorbed dose and type of the IR. These have been reported extensively in human subjects; especially among the victims of the accidental exposure and radiotherapy patients. Additionally, there have been a plethora of studies in animal models which support these findings, and are being used to test radio-mitigative or radio-protective strategies. The vulnerability of neuronal tissue to IR is well known, however the acute dose-dependent behavioural consequences have yet to be understood. Thus, our laboratory has been trying to decipher the dose-dependent behavioural dysfunctions which have occurred 24-72 hours post IR exposure and possible radio-protective strategies. We are utilizing mouse models of studying the behavioural processes, in a test battery conceptualized to study the affective and cognitive skills as well as motor skills of the animals. Additionally, we have observed cellular damage to different areas of the brain and subsequent correlations to behavioural dysfunctions. This has being carried out by using single cell gel electrophoresis (SCGE) and Diffusion Tensor Imaging (DTI). The findings show that after exposure to sub-lethal γ-rays, there are significant changes that occur in all the behavioural parameters. The most sensitive area has been found to be the Hippocampus as visualized by DTI and the SCGE. Consequently, short term and long term memory functions have been shown to be disrupted within 24-72 hours of exposure. Acute dysfunctions of affective functions have also been demonstrated to materialise within 24 hours post exposure. Unexpectedly, the behavioural dysfunctions were seen to be dose independent. Thus, this study provides a foundation to help decipher the acute behavioural manifestations of IR exposure

  16. Computer program for diagnostic X-ray exposure conversion

    International Nuclear Information System (INIS)

    Lewis, S.L.

    1984-01-01

    Presented is a computer program designed to convert any given set of diagnostic X-ray exposure factors sequentially into another, yielding either an equivalent photographic density or one increased or decreased by a specifiable proportion. In addition to containing the wherewithal with which to manipulate a set of exposure factors, the facility to print hard (paper) copy is included enabling the results to be pasted into a notebook and used at any time. This program was originally written as an investigative exercise into examining the potential use of computers for practical radiographic purposes as conventionally encountered. At the same time, its possible use as an educational tool was borne in mind. To these ends, the current version of this program may be used as a means whereby exposure factors used in a diagnostic department may be altered to suit a particular requirement or may be used in the school as a mathematical model to describe the behaviour of exposure factors under manipulation without patient exposure. (author)

  17. Implementation of a primary standard for x-ray exposure

    International Nuclear Information System (INIS)

    Peixoto, Jose Guilherme Pereira

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-ray s of 10OKV to 250kV of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Since the collecting rod is small, and positioned far away from the X-ray beam, only a negligible fraction of ionization (0,01 %) is lost due to interactions with it. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation , beam homogeneity, influence Of beam size and influences of temperature, humidity and atmospheric pressure.Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  18. Radiation exposure with the NOMAD portable X-ray system.

    Science.gov (United States)

    Goren, A D; Bonvento, M; Biernacki, J; Colosi, D C

    2008-02-01

    A new hand-held battery-operated portable X-ray system was tested for possible leakage radiation through the existing heavy metal compounds surrounding the X-ray tube, backscatter radiation through the lead-filled acrylic shield attached at the end of the exit tube and patient exposure. Dose measurements were conducted using a DXTRR phantom and a water phantom. All measurements were recorded using calibrated thermoluminescent dosimetry (TLD), calibrated Unfors Model 583L dosemeter, and a calibrated Radcal MDH model 1015 dosemeter. The settings for all exposure were 60 kVp, 2.3 mA and 0.25 s using Kodak Insight (Class F) film. All backscatter measurements, in front of the shield, behind the shield, at the finger of the operator, the operator's chest, eyes and gonads were significantly below the maximum permissible radiation leakage as per the United States Food and Drug Administration regulations (100 mR h(-1)). Our measurements indicate that the exposure would be well within the occupational maximum permissible dose for an occupationally exposed person. Film dose was consistent with the manufacturer's recommendations. As a result of our measurements, the State of New York Bureau of Environmental Radiation Protection granted us a variance to use the NOMAD on a case-by-case basis. Our data have shown that the NOMAD presents risks that are no greater than with standard dental radiographic units to the patient or operator and the measured doses are well below recommended levels.

  19. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization

    International Nuclear Information System (INIS)

    Holmes, D.R. Jr.; Bove, A.A.; Wondrow, M.A.; Gray, J.E.

    1986-01-01

    A newly developed video x-ray progressive scanning system improves image quality, decreases radiation exposure, and can be added to any pulsed fluoroscopic x-ray system using a video display without major system modifications. With use of progressive video scanning, the radiation entrance exposure rate measured with a vascular phantom was decreased by 32 to 53% in comparison with a conventional fluoroscopic x-ray system. In addition to this substantial decrease in radiation exposure, the quality of the image was improved because of less motion blur and artifact. Progressive video scanning has the potential for widespread application to all pulsed fluoroscopic x-ray systems. Use of this technique should make cardiac catheterization procedures and all other fluoroscopic procedures safer for the patient and the involved medical and paramedical staff

  20. Radiation exposure in X-ray examinations of the pelvis

    International Nuclear Information System (INIS)

    Kainberger, F.

    1977-01-01

    The article reports on radiation exposure during X-ray treatment of the pelvis of children. Special attention is paid to genetical radiation exposure. Generally a dose of 100 mR is assumed to be taken up if no adequate shielding is provided. In order to be able to judge the value of a shielding with suitable lead-equivalent values, measurements were carried out on a phantom. These measurements showed that the dosage can be reduced by at least a factor 100 by using a lead shielding. When doing this, the lead equivalent value must be 1 mm. The form of gonad protection also has great importance for the shielding efficiency. (orig.) [de

  1. Cytogenetic studies with laser or X-ray exposures

    International Nuclear Information System (INIS)

    Bozduganov, A.; Genkov, P.

    1975-01-01

    Account is given of studies involving a total of 21 peripheral blood cultures given the following treatments: exposure to 20 0.13-joule pulses from an optic quantum generator (ruby), 9; exposure to 1000 R X-rays, 9; and unexposed controls, 3. Exposures were carried out on three cultures from each experimental series at each of three time intervals, namely 24 h, 48 h, and 72 h after initiation of cultures. On any day, 40 well-spread metaphases were examined. High quality metaphases were photographed and karyotyped in conformity to the Chicago Conference criteria. In the laser experiment, chromosome aberrations were observed in 65% of methaphases analyzed vs. 5.3% in controls. Anomalies encountered included aneuploidy, with hypoploid metaphases predominating, polyploidy (triploidy, tetraploidy, and partial endoreduplication), and structural alterations. The following structural chromosome rearrangements are found: acentric fragments, mostly pairs, occasionally single, including minute chromosomes; dicentric and tricentric chromosomes; interstitial deletions; and chromosome translocations. Most varied and abundant chromosome aberrations were seen in 72-h irradiated cultures. The data presented offer a new opportunity for assessing genetic lesions after laser exposure and may help to determine threshold doses. (author)

  2. Deformation and stress in PMMA during hard X-ray exposure for deep lithography

    International Nuclear Information System (INIS)

    Moldovan, N.

    1999-01-01

    The availability of high-energy, high-flux, collimated synchrotrons radiation has extended the application of deep X-ray lithography (DXRL) to thickness values of the PMMA resist of several millimeters. Some of the most severe limitations come from plastic deformation, stress, and cracks induced in PMMA during exposure and development. We have observed and characterized these phenomena quantitatively. Profilometry measurements revealed that the PMMA is subjected either to local shrinkage or to expansion, while compression and expansion evolve over time. Due to material loss and crosslinking, the material undergoes a shrinkage, while the radiation-induced decomposition generates gases expanding the polymer matrix. The overall dynamics of the material microrelief and stress during and after the exposure depend on the balance between compaction and outgassing. These depend in turn on the exposure conditions (spectrum; dose, dose rate, seaming, temperature), post-exposure storage conditions, PMMA material properties and thickness, and also on the size and geometry of the exposed patterns

  3. Monitoring method for an ambient Gamma exposure rate and its measurement analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mo Sung [Cheongju Univ., Cheongju (Korea, Republic of); Woo, Jong Kwan [University of Seoul, Seoul (Korea, Republic of)

    2006-12-15

    Daily and seasonal variations of the ambient gamma ray exposure rates were measured by using a pressurized ion chamber from January 2003 to December 2005 in the Cheongju Regional Radiation Monitoring Post and the patterns of the distributions were studied. The annual average of the daily variation of the exposure rate was {approx}0.17 {mu}R/h. The exposure rate was found to be maximum during 8:00 am to 9:00 am and minimum during 8:00 pm to 10:00 pm. For the annual data, the exposure rate was the minimum during the month of February. The exposure rate increased from February to mid-October (except during the period from May to July with no change) and decreased from October to February. The seasonal variation was found to be about 1 {mu}R/h. Most of the measured values (96%) of the exposure rates fell under the normal distribution with a deviation of less than 4.8% and the remaining 4% had large fluctuations caused mainly by the rainfalls.

  4. Absorbed dose rate meter for β-ray

    International Nuclear Information System (INIS)

    Bingo, K.

    1977-01-01

    The absorbed dose of β-ray depends on the energy of β-rays and the epidermal thickness of tissue in interest. In order to measure the absorbed dose rate at the interested tissue directly, the ratio of counting rate to absorbed dose should be constant independent of β-ray energy. In this purpose, a thin plastic scintillator was used as a detector with a single channel analyzer. The pulse height distribution, obtained using the scintillator whose thickness is less than the range of β-rays, shows a peak at a particular pulse height depending on the thickness of scintillator used. This means an increase of the number of pulses at lower pulse height. The lower level of discrimination and window width of the single channel analyzer are chosen according to the epidermal thickness of the tissue. In the experiment, scintillators of 0.5, 1, 2, 3, 5 and 10 mm thick were tested. It was found that desirable pulse height distribution, to obtain a constant dose sensitivity, could be obtained using the 2 mm thick scintillator. The sensitivity of the absorbed dose rate meter is constant within +-15% for β-ray with maximum energy from 0.4 to 3.5 MeV, when the absorbed dose rate for skin (epidermal thickness 7mg/cm 2 ) is measured. In order to measure the dose rate for a hand (epithermal thickness 40mg/cm 2 ) the lower level of discrimination is changed to be higher and at the same time the window width is also changed. Combining these techniques, one can get an absorbed dose rate meter for the tissue dose of various thickness, which has the constant dose sensitivity within +-15% for β-rays with maximum energy from 0.4 to 3.5 MeV

  5. Prediction of gamma exposure rates in large nuclear craters

    Energy Technology Data Exchange (ETDEWEB)

    Tami, Thomas M; Day, Walter C [U.S. Army Engineer Nuclear Cratering Group, Lawrence Radiation Laboratory, Livermore, CA (United States)

    1970-05-15

    In many civil engineering applications of nuclear explosives there is the need to reenter the crater and lip area as soon as possible after the detonation to carry out conventional construction activities. These construction activities, however, must be delayed until the gamma dose rate, or exposure rate, in and around the crater decays to acceptable levels. To estimate the time of reentry for post-detonation construction activities, the exposure rate in the crater and lip areas must be predicted as a function of time after detonation. An accurate prediction permits a project planner to effectively schedule post-detonation activities.

  6. Asymmetric Exchange Rate Exposure - Research in Southeast Asian Countries

    Directory of Open Access Journals (Sweden)

    Minh Thi Hong Le

    2017-04-01

    Full Text Available The study aims to analyse the impact of exchange rate exposure on stock returns in six countries representative of Southeast Asia, including Indonesia, Malaysia, Philippines, Singapore, Thailand and Vietnam from 2009 to 2014. Both nominal and real exchange rates are taken into account for evaluating exchange rate fluctuations via panel data. In order to achieve this goal, a panel regressive estimation approach is proposed in which a GLS model is firstly used to treat heteroscedasticity in the panel data and, then, a GMM estimator is employed to ensure the consistency of the estimates. The results point out that the exchange rate exposure of these countries is asymmetric. At market level, for a rise in the exchange rate (or local currency depreciates, the average stock returns tend to decrease. However, due to the favourable impact of currency depreciation on the net export position, the reduction speed of stock returns is faster than the rising speed of the exchange rate.

  7. Asymmetric Exchange Rate Exposure - Research in Southeast Asian Countries

    OpenAIRE

    Minh Thi Hong Le; Ha Thi Cam Huynh; Hong Thi Thu Dinh

    2017-01-01

    The study aims to analyse the impact of exchange rate exposure on stock returns in six countries representative of Southeast Asia, including Indonesia, Malaysia, Philippines, Singapore, Thailand and Vietnam from 2009 to 2014. Both nominal and real exchange rates are taken into account for evaluating exchange rate fluctuations via panel data. In order to achieve this goal, a panel regressive estimation approach is proposed in which a GLS model is firstly used to treat heteroscedasticity in the...

  8. Digital Intraoral Imaging Re-Exposure Rates of Dental Students.

    Science.gov (United States)

    Senior, Anthea; Winand, Curtis; Ganatra, Seema; Lai, Hollis; Alsulfyani, Noura; Pachêco-Pereira, Camila

    2018-01-01

    A guiding principle of radiation safety is ensuring that radiation dosage is as low as possible while yielding the necessary diagnostic information. Intraoral images taken with conventional dental film have a higher re-exposure rate when taken by dental students compared to experienced staff. The aim of this study was to examine the prevalence of and reasons for re-exposure of digital intraoral images taken by third- and fourth-year dental students in a dental school clinic. At one dental school in Canada, the total number of intraoral images taken by third- and fourth-year dental students, re-exposures, and error descriptions were extracted from patient clinical records for an eight-month period (September 2015 to April 2016). The data were categorized to distinguish between digital images taken with solid-state sensors or photostimulable phosphor plates (PSP). The results showed that 9,397 intraoral images were made, and 1,064 required re-exposure. The most common error requiring re-exposure for bitewing images was an error in placement of the receptor too far mesially or distally (29% for sensors and 18% for PSP). The most common error requiring re-exposure for periapical images was inadequate capture of the periapical area (37% for sensors and 6% for PSP). A retake rate of 11% was calculated, and the common technique errors causing image deficiencies were identified. Educational intervention can now be specifically designed to reduce the retake rate and radiation dose for future patients.

  9. A firm-specific exposure analyis of the exchange-rate exposure of Dutch firms

    NARCIS (Netherlands)

    de Jong, A.; Ligterink, J.; Macrae, V.

    2006-01-01

    We examine the relationship between exchange-rate changes and stock returns for a sample of Dutch firms over 1994-1998. We find that over 50 per cent of the firms are significantly exposed to exchange-rate risk. Furthermore, all firms with significant exchange-rate exposure benefit from a

  10. Childhood cancer after prenatal exposure to diagnostic X-ray examinations in Britain

    International Nuclear Information System (INIS)

    Mole, R.H.

    1990-01-01

    Detailed data were provided by the Oxford Survey of Childhood Cancer OSCC on deaths from childhood cancer in Britain after irradiation of the fetus during diagnostic radiology of the mother. In each age group at death, 0-5, 6-9 and 10-15 years, excess cancer deaths decreased suddenly for births in and after 1958. A major factor was concerted action initiated in 1956 to reduce radiation exposure of fetal gonads for fear of genetic hazards. Dose reduction was achieved during 1957 and early 1958 by reducing the rising rate of obstetric radiography and by virtually abandoning pelvimetry as that had been understood. In the 1970s the rate of X-raying increased again and so did cancer risk but not significantly. Direct evidence that diagnostic X-rays can cause childhood cancer is the similar excess rate per X-ray in twins and singleton births when X-raying rate is 5-6 times higher in twins. (author)

  11. American National Standard: neutron and gamma-ray flux-to-dose rate factors

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard presents data recommended for computing biological dose rates due to neutron and gamma-ray radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are given; the energy range for the gamma-ray conversion factors is 0.01 to 15 MeV. Specifically, this Standard is intended for use by shield designers to calculate wholebody dose rates to radiation workers and the general public. Establishing dose-rate limits is outside the scope of this Standard. Use of this Standard in cases where the dose equivalents are far in excess of occupational exposure guidelines is not recommended

  12. Influence of radiation exposure rate on somatic mutation frequency and loss of reproductive integrity in tradescantia stamen hairs

    International Nuclear Information System (INIS)

    Ichikawa, S.; Nauman, C.H.; Sparrow, A.H.; Takahashi, C.S.

    1978-01-01

    Inflorescences of Tradescantia clone 02 (2n=12), hetero- or hemi-zygous for flower color, were exposed to a series of γ-ray exposures at two different exposure rates, 29.3 R/min and 0.026-0.52 R/min. Pink mutation-response curves, and survival curves based on reproductive integrity, were constructed for each of the exposure rates. Loss of reproductive integrity was also assessed at high (256 R/min) and low (0.52-4.17 R/min) γ-ray exposure rates in T. blossfeldiana (2n=72). All observations were made on stamen hairs. The higher exposure rate was 1.3-1.7 times more effective in inducing pink mutations in clone 02. A greater efficiency of the higher exposure rate was also found for both taxa at the loss of reproductive integrity endpoint. The D 0 values obtained at the higher exposure rates, 154 R for clone 02 and 720 R for T. blossfeldiana, were significantly lower than the corresponding values of 270 R and 1880 R obtained at the lower exposure rates. These D 0 's differ by factors of 1.75 and 2.61 for clone 02 and T. blossfeldiana, respectively. D 0 's for the two taxa were found to be inversely correlated with their interphase chromosome volumes. (Auth.)

  13. Robust ray-tracing algorithms for interactive dose rate evaluation

    International Nuclear Information System (INIS)

    Perrotte, L.

    2011-01-01

    More than ever, it is essential today to develop simulation tools to rapidly evaluate the dose rate received by operators working on nuclear sites. In order to easily study numerous different scenarios of intervention, computation times of available softwares have to be all lowered. This mainly implies to accelerate the geometrical computations needed for the dose rate evaluation. These computations consist in finding and sorting the whole list of intersections between a big 3D scene and multiple groups of 'radiative' rays meeting at the point where the dose has to be measured. In order to perform all these computations in less than a second, we first propose a GPU algorithm that enables the efficient management of one big group of coherent rays. Then we present a modification of this algorithm that guarantees the robustness of the ray-triangle intersection tests through the elimination of the precision issues due to floating-point arithmetic. This modification does not require the definition of scene-dependent coefficients ('epsilon' style) and only implies a small loss of performance (less than 10%). Finally we propose an efficient strategy to handle multiple ray groups (corresponding to multiple radiative objects) which use the previous results.Thanks to these improvements, we are able to perform an interactive and robust dose rate evaluation on big 3D scenes: all of the intersections (more than 13 million) between 700 000 triangles and 12 groups of 100 000 rays each are found, sorted along each ray and transferred to the CPU in 470 milliseconds. (author) [fr

  14. Exchange Rate Exposure Management: "Speculation" in Non-Financial Companies

    DEFF Research Database (Denmark)

    Aabo, Tom

    "Speculation" in non-financial companies in relation to exchange rate exposure management constitutes one of the contributing factors behind corporate (or more widespread) crises. Deviations from benchmark positions constitute speculation. An empirical study of Danish non-financial companies finds...... that the larger the company (ability) and the larger its relative sale on foreign markets (relevance), the more likely the company will be to benchmark its exchange rate exposures. However, at the same time the very same factors (size and foreign sale) lead to more extensive speculation. Financial solvency (value...

  15. E-Commerce and Exchange Rate Exposure Management

    DEFF Research Database (Denmark)

    Aabo, Tom

    2001-01-01

    The aim of this paper is to address the impact of E-commerce on the balance between real hedging and financial hedging in the context of exchange rate exposure management in non-financial companies. A cross-case study of industrial companies highlights the inadequacy in taking a partial and static...... financial approach when managing exchange rate exposures. The paper argues that the emergence of E-commerce - by reducing the cost of obtaining, analyzing and allocating information - affects the dynamics of the markets and the dynamics of the company in such a way that a general tilt towards real hedging...

  16. Hospital and clinic survey estimates of medical x-ray exposures in Hiroshima and Nagasaki, (1)

    International Nuclear Information System (INIS)

    Sawada, Shozo; Land, C.E.; Otake, Masanori; Russell, W.J.; Takeshita, Kenji.

    1980-11-01

    All large hospitals and 40% of the small hospitals and clinics in Hiroshima and Nagasaki cities were surveyed for the X-ray examinations they performed during a 2-week period in 1974. The frequency and type of X-ray examinations received by members of the RERF Adult Health Study (AHS) and the RERF Life Span Study (LSS) extended, excluding AHS (Non-AHS), were compared with the general population in each city. Radiologic exposures of patients at hospitals and clinics were most frequent among the general populations. The number of patients, examinations, and exposures per caput per year in each population were estimated. Since the age distribution differed among the three populations, comparisons were made only after correcting for age. On a per caput per year basis exposure frequency was relatively high in the AHS and low in the general populations, a reflection of the greater number of patients in the AHS than in the general populations. Non-AHS males in Nagasaki had a higher X-ray examination rate than did the AHS subjects. The others in the Non-AHS did not differ appreciably from the general populations. There was no difference among these groups according to body sites examined. (author)

  17. Gardening process of lunar surface layer inferred from the galactic cosmic-ray exposure ages of lunar samples

    International Nuclear Information System (INIS)

    Iriyama, Jun; Honda, Masatake.

    1979-01-01

    From the cosmic-ray exposure age data, (time scale 10 7 - 10 8 years), of the lunar surface materials, we discuss the gardening process of the lunar surface layer caused by the meteoroid impact cratering. At steady state, it is calculated that, in the region within 10 - 50 m of the surface, a mixing rate of 10 -4 to 10 -5 mm/yr is necessary to match the exposure ages. Observed exposure ages of the lunar samples could be explained by the gardening effect calculated using a crater formation rate which is slightly modified from the current crater population data. (author)

  18. Mercury Exposure and Heart Rate Variability: A Systematic Review

    Science.gov (United States)

    Gribble, Matthew O.; Cheng, Alan; Berger, Ronald D.; Rosman, Lori; Guallar, Eliseo

    2015-01-01

    Background Mercury affects the nervous system and has been implicated in altering heart rhythm and function. We sought to better define its role in modulating heart rate variability, a well-known marker of cardiac autonomic function. Design Systematic review. Methods We searched PubMed, Embase, TOXLINE and DART databases without language restriction. We report findings as a qualitative systematic review because heterogeneity in study design and assessment of exposures and outcomes across studies, as well as other methodological limitations of the literature, precluded a quantitative meta-analysis. Results We identified 12 studies of mercury exposure and heart rate variability in human populations (10 studies involving primarily environmental methylmercury exposure and two studies involving occupational exposure to inorganic mercury) conducted in Japan, the Faroe Islands, Canada, Korea, French Polynesia, Finland and Egypt. The association of prenatal mercury exposure with lower high-frequency band scores (thought to reflect parasympathetic activity) in several studies, in particular the inverse association of cord blood mercury levels with the coefficient of variation of the R-R intervals and with low frequency and high frequency bands at 14 years of age in the Faroe Islands birth cohort study, suggests that early mercury exposure could have a long-lasting effect on cardiac parasympathetic activity. Studies with later environmental exposures to mercury in children or in adults were heterogeneous and did not show consistent associations. Conclusions The evidence was too limited to draw firm causal inferences. Additional research is needed to elucidate the effects of mercury on cardiac autonomic function, particularly as early-life exposures might have lasting impacts on cardiac parasympathetic function. PMID:26231507

  19. Differences of X-ray exposure between X-ray diagnostics with a conventional X-ray screen-system and with an image-intensifier-television-unit

    International Nuclear Information System (INIS)

    Loehr, H.; Vogel, H.; Reinhart, J.; Jantzen, R.

    1977-01-01

    During X-ray diagnostics of patients in the II. Medizinische Poliklinik the X-ray exposure was determined. It corresponded to the data described in literature. Two groups were compared: 518 patients examined with a conventional X-ray screen-system and 642 patients examined with an image-intensifier-television-system. The results demonstrated that with exception of thoracical X-ray examination the replacing of the old system by the television system brought a remarkable increase of the X-ray exposure. The doses depended of the patients constitution to a high degree. (orig.) [de

  20. Activity, exposure rate and spectrum prediction with Java programming

    International Nuclear Information System (INIS)

    Sahin, D.; Uenlue, K.

    2009-01-01

    In order to envision the radiation exposure during Neutron Activation Analysis (NAA) experiments, a software called Activity Predictor is developed using Java TM programming language. The Activity Predictor calculates activities, exposure rates and gamma spectra of activated samples for NAA experiments performed at Radiation Science and Engineering Center (RSEC), Penn State Breazeale Reactor (PSBR). The calculation procedure for predictions involves both analytical and Monte Carlo methods. The Activity Predictor software is validated with a series of activation experiments. It has been found that Activity Predictor software calculates the activities and exposure rates precisely. The software also predicts gamma spectrum for each measurement. The predicted spectra agreed partially with measured spectra. The error in net photo peak areas varied from 4.8 to 51.29%, which is considered to be due to simplistic modeling, statistical fluctuations and unknown contaminants in the samples. (author)

  1. A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems

    International Nuclear Information System (INIS)

    Yadava, G K; Kuhls-Gilcrist, A T; Rudin, S; Patel, V K; Hoffmann, K R; Bednarek, D R

    2008-01-01

    The performance of high-sensitivity x-ray imagers may be limited by additive instrumentation noise rather than by quantum noise when operated at the low exposure rates used in fluoroscopic procedures. The equipment-invasive instrumentation noise measures (in terms of electrons) are generally difficult to make and are potentially not as helpful in clinical practice as would be a direct radiological representation of such noise that may be determined in the field. In this work, we define a clinically relevant representation for instrumentation noise in terms of noise-equivalent detector entrance exposure, termed the instrumentation noise-equivalent exposure (INEE), which can be determined through experimental measurements of noise-variance or signal-to-noise ratio (SNR). The INEE was measured for various detectors, thus demonstrating its usefulness in terms of providing information about the effective operating range of the various detectors. A simulation study is presented to demonstrate the robustness of this metric against post-processing, and its dependence on inherent detector blur. These studies suggest that the INEE may be a practical gauge to determine and compare the range of quantum-limited performance for clinical x-ray detectors of different design, with the implication that detector performance at exposures below the INEE will be instrumentation-noise limited rather than quantum-noise limited

  2. Race, Exposure, and Initial Affective Ratings in Interpersonal Attraction.

    Science.gov (United States)

    Nikels, Kenneth W.; Hamm, Norman H.

    To test the mere exposure hypothesis, subjects were exposed to 20 slides of black and white stimulus persons. Based upon pre-experimental ratings, each slide had been initially assigned to one of four groups: high favorable black, high favorable white, low favorable black, and low favorable white. The experimental group, consisting of 25 white…

  3. Soft X ray spectrometry at high count rates

    International Nuclear Information System (INIS)

    Blanc, P.; Brouquet, P.; Uhre, N.

    1978-06-01

    Two modifications of the classical method of X-ray spectrometry by a semi-conductor diode permit a count rate of 10 5 c/s with an energy resolution of 350 eV. With a specially constructed pulse height analyzer, this detector can measure four spectra of 5 ms each, in the range of 1-30 keV, during a plasma shot

  4. Effective dose rate coefficients for exposure to contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K.G. [Easterly Scientific, Knoxville, TN (United States); Y-12 National Security Complex, Oak Ridge, TN (United States); Eckerman, K.F.; Easterly, C.E. [Easterly Scientific, Knoxville, TN (United States); Bellamy, M.B.; Hiller, M.M.; Dewji, S.A. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Hertel, N.E. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Georgia Institute of Technology, Atlanta, GA (United States); Manger, R. [University of California San Diego, Department of Radiation Medicine and Applied Sciences, La Jolla, CA (United States)

    2017-08-15

    The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios. (orig.)

  5. Advanced digital counting rate meter for gamma ray logging

    International Nuclear Information System (INIS)

    Kannan, S.; Meenakshi Sundari, A.; Rai, A.K.

    2013-01-01

    A compact, hand held controller based Advanced Digital Count Rate Meter (ADCRM) as a replacement of bulky Count Rate (analog) Meters (SBL-2A) was designed, developed and fabricated to carry out Gamma-Ray borehole logging with Geiger Muller (GM) tubes and Scintillation (SC) detectors. In the hardware the functionality of analog meter simulation, digital counting of gamma events and auto reference adjustment to use different length of armour cable winches were implemented. The in-built software evaluates grade in ppm and at the end of logging, the reports are prepared automatically. ADCRM was developed in-house to assist the uranium mineral exploration in AMD. (author)

  6. Modulation of expression of genes encoding nuclear proteins following exposure to JANUS neutrons or γ-rays

    International Nuclear Information System (INIS)

    Woloschak, G.E.; Chang-Liu, Chin-Mei

    1994-01-01

    Previous work has shown that exposure of cells to ionizing radiations causes modulation of a variety of genes, including those encoding c-fos, interleukin-1, tumor necrosis factor, cytoskeletal elements, and many more. The experiments reported herein were designed to examine the effects of either JANUS neutron or γ-ray exposure on expression of genes encoding nucleus-associated proteins (H4-histone, c-jun, c-myc, Rb, and p53). Cycling Syrian hamster embryo cells were irradiated with varying doses and dose rates of either JANUS fission-spectrum neutrons or γ-rays; after incubation of the cell cultures for 1 h following radiation exposure, mRNA was harvested and analyzed by Northern blot. Results revealed induction of transcripts for c-jun, H4-histone, and Rb following γ-ray but not following neutron exposure. Interestingly, expression of c-myc was repressed following γ-ray but not following neutron exposure. Radiations at different doses and dose rates were compared for each of the genes studied

  7. Study of tourists exposure rate in Mahallat hot Spring Region

    International Nuclear Information System (INIS)

    Tavakoli, H. M.B.; Fallah, M.G.; Ghiasinejad, M.

    2006-01-01

    Introduction: High level radiation areas have been recognized on various parts of the earth. Some of these areas include: Brasilia, India, and Iran. Mahallat hot spring region in the central part of Iran is also one of these areas. Study of exposure in these areas could be helpful in investigating the effects of ionizing radiation. Materials and Methods: In addition to several seasonal springs, Mahallat hot spring region contains five permanent springs named: Soleimani, Shafa, Dombe, Romatism and Sauda. Internal exposure (due to inhalation of radon gas and drinking water) and external exposure (due to cosmic rays and radioactive elements in the ground) to the tourists was studied. Used materials and apparatus include: RSS -112 ionizing chamber for environmental gamma rays exposure measurement, highly pure germanium detector for measuring radioactive elements in the ground, liquid scintillation counter for measuring 222 Rn gas concentration in water samples, Bubbler chamber and Locus cells for Rn concentration measurements (Emanation method) and Alfa guard detector for 226 Ra concentration measurements. Conclusions and Discussion: A total of 270 visitors are included in this study. Considering residual durations of the studied group in open and closed environment of bathrooms, hotel and inn rooms, obtained annual external effective dose is 75.4±8.7μSv and 138.3±11.8μSv for natives and travelers respectively. EEC coefficients has been used for calculating annual internal effective dose due to radon gas inhalation. Annual internal effective dose, in this path, is 0.9 and 2.1 mSv in open and closed environment for native and visitors respectively. Annual internal effective dose due to drinking water, is 0.43 and 0.09μSv for natives people and travelers, respectively. Measurements show that more than 90% of the received dose in the studied groups is due to radon gas inhalation. External and internal dose summation is 0.98 mSv for natives and 2.2 mSv for for

  8. Study of tourists exposure rate in Mahallat hot Spring Region

    Energy Technology Data Exchange (ETDEWEB)

    Tavakoli, H. M.B. [Isfahan Univ. of Medical Sciences, Isfahan (Iran, Islamic Republic of); Fallah, M.G. [Isfahan University of Medical Sciences (Iran, Islamic Republic of); Ghiasinejad, M. [Iran Atomic Energy Organization, Tehran (Iran, Islamic Republic of)

    2006-07-01

    Introduction: High level radiation areas have been recognized on various parts of the earth. Some of these areas include: Brasilia, India, and Iran. Mahallat hot spring region in the central part of Iran is also one of these areas. Study of exposure in these areas could be helpful in investigating the effects of ionizing radiation. Materials and Methods: In addition to several seasonal springs, Mahallat hot spring region contains five permanent springs named: Soleimani, Shafa, Dombe, Romatism and Sauda. Internal exposure (due to inhalation of radon gas and drinking water) and external exposure (due to cosmic rays and radioactive elements in the ground) to the tourists was studied. Used materials and apparatus include: RSS -112 ionizing chamber for environmental gamma rays exposure measurement, highly pure germanium detector for measuring radioactive elements in the ground, liquid scintillation counter for measuring {sup 222}Rn gas concentration in water samples, Bubbler chamber and Locus cells for Rn concentration measurements (Emanation method) and Alfa guard detector for {sup 226}Ra concentration measurements. Conclusions and Discussion: A total of 270 visitors are included in this study. Considering residual durations of the studied group in open and closed environment of bathrooms, hotel and inn rooms, obtained annual external effective dose is 75.4{+-}8.7{mu}Sv and 138.3{+-}11.8{mu}Sv for natives and travelers respectively. EEC coefficients has been used for calculating annual internal effective dose due to radon gas inhalation. Annual internal effective dose, in this path, is 0.9 and 2.1 mSv in open and closed environment for native and visitors respectively. Annual internal effective dose due to drinking water, is 0.43 and 0.09{mu}Sv for natives people and travelers, respectively. Measurements show that more than 90% of the received dose in the studied groups is due to radon gas inhalation. External and internal dose summation is 0.98 mSv for natives and 2

  9. Modeling emission rates and exposures from outdoor cooking

    Science.gov (United States)

    Edwards, Rufus; Princevac, Marko; Weltman, Robert; Ghasemian, Masoud; Arora, Narendra K.; Bond, Tami

    2017-09-01

    Approximately 3 billion individuals rely on solid fuels for cooking globally. For a large portion of these - an estimated 533 million - cooking is outdoors, where emissions from cookstoves pose a health risk to both cooks and other household and village members. Models that estimate emissions rates from stoves in indoor environments that would meet WHO air quality guidelines (AQG), explicitly don't account for outdoor cooking. The objectives of this paper are to link health based exposure guidelines with emissions from outdoor cookstoves, using a Monte Carlo simulation of cooking times from Haryana India coupled with inverse Gaussian dispersion models. Mean emission rates for outdoor cooking that would result in incremental increases in personal exposure equivalent to the WHO AQG during a 24-h period were 126 ± 13 mg/min for cooking while squatting and 99 ± 10 mg/min while standing. Emission rates modeled for outdoor cooking are substantially higher than emission rates for indoor cooking to meet AQG, because the models estimate impact of emissions on personal exposure concentrations rather than microenvironment concentrations, and because the smoke disperses more readily outdoors compared to indoor environments. As a result, many more stoves including the best performing solid-fuel biomass stoves would meet AQG when cooking outdoors, but may also result in substantial localized neighborhood pollution depending on housing density. Inclusion of the neighborhood impact of pollution should be addressed more formally both in guidelines on emissions rates from stoves that would be protective of health, and also in wider health impact evaluation efforts and burden of disease estimates. Emissions guidelines should better represent the different contexts in which stoves are being used, especially because in these contexts the best performing solid fuel stoves have the potential to provide significant benefits.

  10. Alteration of the Carbon and Nitrogen Isotopic Composition in the Martian Surface Rocks Due to Cosmic Ray Exposure

    Science.gov (United States)

    Pavlov, A. A.; Pavlov, A. K.; Ostryakov, V. M.; Vasilyev, G. I.; Mahaffy, P.; Steele, A.

    2014-01-01

    C-13/C-12 and N-15/N-14 isotopic ratios are pivotal for our understanding of the Martian carbon cycle, history of the Martian atmospheric escape, and origin of the organic compounds on Mars. Here we demonstrate that the carbon and nitrogen isotopic composition of the surface rocks on Mars can be significantly altered by the continuous exposure of Martian surface to cosmic rays. Cosmic rays can effectively produce C-13 and N-15 isotopes via spallation nuclear reactions on oxygen atoms in various Martian rocks. We calculate that in the top meter of the Martian rocks, the rates of production of both C-13 and N-15 due to galactic cosmic rays (GCRs) exposure can vary within 1.5-6 atoms/cm3/s depending on rocks' depth and chemical composition. We also find that the average solar cosmic rays can produce carbon and nitrogen isotopes at a rate comparable to GCRs in the top 5-10 cm of the Martian rocks. We demonstrate that if the total carbon content in a surface Martian rock is <10 ppm, then the "light," potentially "biological" C-13/C-12 ratio would be effectively erased by cosmic rays over 3.5 billion years of exposure. We found that for the rocks with relatively short exposure ages (e.g., 100 million years), cosmogenic changes in N-15/N-14 ratio are still very significant. We also show that a short exposure to cosmic rays of Allan Hills 84001 while on Mars can explain its high-temperature heavy nitrogen isotopic composition (N-15/N-14). Applications to Martian meteorites and the current Mars Science Laboratory mission are discussed.

  11. Potential radiological exposure rates resulting from hypothetical dome failure at Tank W-10

    International Nuclear Information System (INIS)

    1994-07-01

    The main plant area at Oak Ridge National Laboratory (ORNL) contains 12 buried Gunite tanks that were used for the storage and transfer of liquid radioactive waste. Although the tanks are no longer in use, they are known to contain some residual contaminated sludges and liquids. In the event of an accidental tank dome failure, however unlikely, the liquids, sludges, and radioactive contaminants within the tank walls themselves could create radiation fields and result in above-background exposures to workers nearby. This Technical Memorandum documents a series of calculations to estimate potential radiological exposure rates and total exposures to workers in the event of a hypothetical collapse of a Gunite tank dome. Calculations were performed specifically for tank W-10 because it contains the largest radioactivity inventory (approximately half of the total activity) of all the Gunite tanks. These calculations focus only on external, direct gamma exposures for prescribed, hypothetical exposure scenarios and do not address other possible tank failure modes or routes of exposure. The calculations were performed with established, point-kernel gamma ray modeling codes

  12. Potential radiological exposure rates resulting from hypothetical dome failure at Tank W-10

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The main plant area at Oak Ridge National Laboratory (ORNL) contains 12 buried Gunite tanks that were used for the storage and transfer of liquid radioactive waste. Although the tanks are no longer in use, they are known to contain some residual contaminated sludges and liquids. In the event of an accidental tank dome failure, however unlikely, the liquids, sludges, and radioactive contaminants within the tank walls themselves could create radiation fields and result in above-background exposures to workers nearby. This Technical Memorandum documents a series of calculations to estimate potential radiological exposure rates and total exposures to workers in the event of a hypothetical collapse of a Gunite tank dome. Calculations were performed specifically for tank W-10 because it contains the largest radioactivity inventory (approximately half of the total activity) of all the Gunite tanks. These calculations focus only on external, direct gamma exposures for prescribed, hypothetical exposure scenarios and do not address other possible tank failure modes or routes of exposure. The calculations were performed with established, point-kernel gamma ray modeling codes.

  13. Cosmic rays exposure during aircraft flight (3). Guideline and dose evaluation

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    2007-01-01

    Radiation Council of MEXT drew up the Guideline of Cosmic Ray Exposure Control for Air Crew in 2006. The content of the Guideline and evaluation methods of dose are explained. The Guideline stated five items for Airline Company. It consists of 1) exposure dose control for air crew, 2) evaluation methods of cosmic rays exposure dose of air crew, 3) explanation and education of cosmic rays exposure for air crew, 4) reading, record and store of cosmic rays exposure dose of air crew, and 5) health control of air crew. The doses of four airlines were calculated by the Civil Aeromedical Research Institute (CARI) code and the European Program package for the Calculation of Aviation Route Doses (EPCARD) code. The difference of two codes was about 15 to 25%. Japanese Internet System for Calculation of Aviation Route Doses (JISCAED) has been developed by Japan. (S.Y.)

  14. Real-Time Aircraft Cosmic Ray Radiation Exposure Predictions from the NAIRAS Model

    Science.gov (United States)

    Mertens, C. J.; Tobiska, W.; Kress, B. T.; Xu, X.

    2012-12-01

    The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) is a prototype operational model for predicting commercial aircraft radiation exposure from galactic and solar cosmic rays. NAIRAS predictions are currently streaming live from the project's public website, and the exposure rate nowcast is also available on the SpaceWx smartphone app for iPhone, IPad, and Android. Cosmic rays are the primary source of human exposure to high linear energy transfer radiation at aircraft altitudes, which increases the risk of cancer and other adverse health effects. Thus, the NAIRAS model addresses an important national need with broad societal, public health and economic benefits. There is also interest in extending NAIRAS to the LEO environment to address radiation hazard issues for the emerging commercial spaceflight industry. The processes responsible for the variability in the solar wind, interplanetary magnetic field, solar energetic particle spectrum, and the dynamical response of the magnetosphere to these space environment inputs, strongly influence the composition and energy distribution of the atmospheric ionizing radiation field. Real-time observations are required at a variety of locations within the geospace environment. The NAIRAS model is driven by real-time input data from ground-, atmospheric-, and space-based platforms. During the development of the NAIRAS model, new science questions and observational data gaps were identified that must be addressed in order to obtain a more reliable and robust operational model of atmospheric radiation exposure. The focus of this talk is to present the current capabilities of the NAIRAS model, discuss future developments in aviation radiation modeling and instrumentation, and propose strategies and methodologies of bridging known gaps in current modeling and observational capabilities.

  15. The parameters of X-ray equipment that influence in patient exposure

    International Nuclear Information System (INIS)

    Peixoto, J.E.

    1988-01-01

    The main components of the X-rays equipment and the secondary device for radiodiagnosis examination are showed. The influence of all radiographs parameters in human exposure as tension and current are also analysed. (C.G.C.) [pt

  16. Influence of X-ray exposure on morphologic composition of blood of sheep

    International Nuclear Information System (INIS)

    Tukhtaev, T.M.; Badalov, S.

    1983-01-01

    Present article is devoted influence of X-ray exposure on morphologic composition of blood of sheep. Thus, pathogenetic mechanisms of formation of acute radiation sickness of laboratory animals are studied. The experiments are described.

  17. Exposure rates from concrete covered cylindrical units containing radioactive waste

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.

    1983-03-01

    Exposure rates from cylindrical waste units containing the nuclides 60 Co, 134 Cs and 137 Cs homogeneously mixed in a solidification product have been calculated. Analyses have been made for single drums and for two disposal geometries, one with the units placed below ground near the surface in a circular geometry, and one with the units placed on the ground in a pile behind a concrete wall. Due to self-shielding of the units, the exposure rate from the two geometries will be a factor of only 10 - 20 higher than from a single unit, even without soil or wall shielding. With one meter of soil above the circular pile below ground, a reduction factor of 5.10 3 to 5.10 4 can be achieved, depending on the nuclide considered. Placing a one-meter concrete wall in front of the drum pile on the ground gives rise to a reduction factor in the range of 5.10 5 to 2.10 7 . (author)

  18. Effect of continuous gamma-ray exposure on performance of learned tasks and effect of subsequent fractionated exposures on blood-forming tissue

    Science.gov (United States)

    Spalding, J. F.; Holland, L. M.; Prine, J. R.; Farrer, D. N.; Braun, R. G.

    1972-01-01

    Sixteen monkeys trained to perform continuous and discrete-avoidance and fixed-ratio tasks with visual and auditory cues were performance-tested before, during, and after 10-day gamma-ray exposures totaling 0, 500, 750, and 1000 rads. Approximately 14 months after the performance-test exposures, surviving animals were exposed to 100-rad gamma-ray fractions at 56-day intervals to observe injury and recovery patterns of blood-forming tissues. The fixed-ratio, food-reward task performance showed a transient decline in all dose groups within 24 hours of the start of gamma-ray exposure, followed by recovery to normal food-consumption levels within 48 to 72 hours. Avoidance tasks were performed successfully by all groups during the 10-day exposure, but reaction times of the two higher dose-rate groups in which animals received 3 and 4 rads per hour or total doses of 750 and 1000 rads, respectively, were somewhat slower.

  19. Fabrication of open-top microchannel plate using deep X-ray exposure mask made with silicon on insulator substrate

    CERN Document Server

    Fujimura, T; Etoh, S I; Hattori, R; Kuroki, Y; Chang, S S

    2003-01-01

    We propose a high-aspect-ratio open-top microchannel plate structure. This type of microchannel plate has many advantages in electrophoresis. The plate was fabricated by deep X-ray lithography using synchrotron radiation (SR) light and the chemical wet etching process. A deep X-ray exposure mask was fabricated with a silicon on insulator (SOI) substrate. The patterned Si microstructure was micromachined into a thin Si membrane and a thick Au X-ray absorber was embedded in it by electroplating. A plastic material, polymethylmethacrylate (PMMA) was used for the plate substrate. For reduction of the exposure time and high-aspect-ratio fast wet development, the fabrication condition was optimized with respect to not the exposure dose but to the PMMA mean molecular weight (M.W.) changing after deep X-ray exposure as measured by gel permeation chromatography (GPC). Decrement of the PMMA M.W. and increment of the wet developer temperature accelerated the etching rate. Under optimized fabrication conditions, a microc...

  20. Expression of cytoskeletal and matrix genes following exposure to ionizing radiation: Dose-rate effects and protein synthesis requirements

    International Nuclear Information System (INIS)

    Woloschak, G.E.

    1994-01-01

    Experiments were designed to examine the effects Of radiation dose-rate and of the protein synthesis inhibitor cycloheximide on expression of cytoskeletal elements (γ- and β-actin and α-tubulin) and matrix elements (fibronectin) in Syrian hamster embryo cells. Past work from our laboratory had already demonstrated optimum time points and doses for examination of radiation effects on accumulation of specific transcripts. Our results here demonstrated little effect of dose-rate for JANUS fission spectrum neutrons when comparing expression of either α-tubulin or fibronectin genes. Past work had already documented similar results for expression of actin transcripts. Effects of cycloheximide revealed that cycloheximide repressed accumulation of α-tubulin following exposure to high dose-rate neutrons or γ rays; this did not occur following similar low dose-rate exposure. (2) Cycloheximide did not affect accumulation of MRNA for actin genes; and that cycloheximide abrogated the moderate induction of fibronectin-mRNA which occurred following exposure to γ rays and high dose-rate neutrons. These results suggest a role for labile proteins in the maintenance of α-tubulin and fibronectin MRNA accumulation following exposure to ionizing radiation. in addition, they suggest that the cellular/molecular response to low dose-rate neutrons may be different from the response to high dose-rate neutrons

  1. Expression of cytoskeletal and matrix genes following exposure to ionizing radiation: Dose-rate effects and protein synthesis requirements

    International Nuclear Information System (INIS)

    Woloschak, G.E.; Felcher, P.; Chang-Liu, Chin-Mei

    1992-01-01

    Experiments were designed to examine the effects of radiation dose-rate and of the protein synthesis inhibitor cycloheximide on expression of cytoskeletal elements (γ- and β-actin and α-tubulin) and matrix elements (fibronectin) in Syrian hamster embryo cells. Past work from our laboratory had already demonstrated optimum time points and doses for examination of radiation effects on accumulation of specific transcripts. Our results here demonstrated little effect of dose-rate for JANUS fission spectrum neutrons when comparing expression of either α-tubulin or fibronectin genes. Past work had already documented similar results for expression of actin transcripts. Effects of cycloheximide, however, revealed several interesting and novel findings: (1) Cycloheximide repressed accumulation of α-tubulin following exposure to high dose-rate neutrons or γ rays; this did not occur following similar low dose-rate exposure (2) Cycloheximide did not affect accumulation of mRNA for actin genes. Cycloheximide abrogated the moderate induction of fibronectin-mRNA which occurred following exposure to γ rays and high dose-rate neutrons. These results suggest a role for labile proteins in the maintenance of α-tubulin and fibronectin mRNA accumulation following exposure to ionizing radiation. In addition, they suggest that the cellular/molecular response to low dose-rate neutrons may be different from the response to high dose-rate neutrons

  2. Calibration of diagnostic x-ray machines using radiation exposure and radiographic parameters

    International Nuclear Information System (INIS)

    Agba, E.H.; Uloko, P. I.; Tyovenda, A. A.

    2011-01-01

    Calibration of diagnostic x-ray machines using radiation exposure and radiographic parameters of the x-ray machines has been carried out. Three phase diagnostic x-ray machines situated at Federal Medical Centre, Makurdi, General Hospital, Otukpo and Christian Hospital, Mkar were used for the calibration work. The radiation meter was used to measure x-ray radiation exposure. The result of this work demonstrates mR/mAs=C(KV p ) that there exist a power law relation of the form between the radiation exposure and the radiographic parameters of diagnostic x-ray machines, which can be used to estimate patient exposure during routine x-ray diagnostic examinations for wide range of operating parameters. The values of the power exponent n, constant c and total filtrations of the diagnostic x-ray machines have been estimated. These values for the diagnostic x-ray machines at the Federal Medical Centre, Makurdi are: 2.14, 0.88 and 2.77 respectively, for the one at the General Hospital, Otukpo are: 2.07, 0.76 and 2.68 respectively and that of the Christian Hospital, Mkar are: 2.01,0.69 and 2.61 respectively.

  3. Genotoxic effects of high dose rate X-ray and low dose rate gamma radiation in ApcMin/+ mice.

    Science.gov (United States)

    Graupner, Anne; Eide, Dag M; Brede, Dag A; Ellender, Michele; Lindbo Hansen, Elisabeth; Oughton, Deborah H; Bouffler, Simon D; Brunborg, Gunnar; Olsen, Ann Karin

    2017-10-01

    Risk estimates for radiation-induced cancer in humans are based on epidemiological data largely drawn from the Japanese atomic bomb survivor studies, which received an acute high dose rate (HDR) ionising radiation. Limited knowledge exists about the effects of chronic low dose rate (LDR) exposure, particularly with respect to the application of the dose and dose rate effectiveness factor. As part of a study to investigate the development of colon cancer following chronic LDR vs. acute HDR radiation, this study presents the results of genotoxic effects in blood of exposed mice. CBAB6 F1 Apc +/+ (wild type) and Apc Min/+ mice were chronically exposed to estimated whole body absorbed doses of 1.7 or 3.2 Gy 60 Co-γ-rays at a LDR (2.2 mGy h -1 ) or acutely exposed to 2.6 Gy HDR X-rays (1.3 Gy min -1 ). Genotoxic endpoints assessed in blood included chromosomal damage (flow cytometry based micronuclei (MN) assay), mutation analyses (Pig-a gene mutation assay), and levels of DNA lesions (Comet assay, single-strand breaks (ssb), alkali labile sites (als), oxidized DNA bases). Ionising radiation (ca. 3 Gy) induced genotoxic effects dependent on the dose rate. Chromosomal aberrations (MN assay) increased 3- and 10-fold after chronic LDR and acute HDR, respectively. Phenotypic mutation frequencies as well as DNA lesions (ssb/als) were modulated after acute HDR but not after chronic LDR. The Apc Min/+ genotype did not influence the outcome in any of the investigated endpoints. The results herein will add to the scant data available on genotoxic effects following chronic LDR of ionising radiation. Environ. Mol. Mutagen. 58:560-569, 2017. © 2017 The Authors Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society. © 2017 The Authors Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society.

  4. A hard x-ray prototype production exposure station at NSLS

    International Nuclear Information System (INIS)

    Johnson, E.D.; Milne, J.C.

    1997-07-01

    Exposures conducted at the NSLS R and D beamline (X-27B) for High Aspect Ratio Precision Manufacture have proven sufficiently successful that the authors are constructing a dedicated hard x-ray exposure beamline. The new beamline (X-14B) provides an exposure field ∼ 120 mm wide, three times larger than that of X-27B. The scanner is based on the hydraulic system from the X-27B program. It is optimized for planar exposures and takes advantage of the full 525 mm stroke available. Exposures of multiple substrates and masks will be possible, with the fixturing supporting mounting of substrate holders from other groups (ALS, APS, CAMD, and UW). The function of this beamline is to establish a hard x-ray exposure station where manufacturing scale protocols can be developed and ultimately exploited for production runs

  5. Pregnancy x-rays and childhood cancers: effects of exposure age and radiation dose

    International Nuclear Information System (INIS)

    Gilman, E.A.; Kneale, G.W.; Knox, E.G.; Stewart, A.M.

    1988-01-01

    Using data from the Oxford Survey of Childhood Cancers this paper examines the effect of foetal age and number of films used on the subsequent risk of childhood cancer associated with prenatal x-rays. X-rays early in pregnancy were taken for different reasons and required more films when compared with those taken in late pregnancy. Therefore, Mantel-Haenszel techniques were used to estimate the independent effects of (a) exposure age and (b) number of films. Age at exposure had a clearly significant effect; x-rays taken in the first trimester of pregnancy were 2.69 times as effective as x-rays taken in the third trimester. First trimester exposures were often the result of maternal illnesses, so these maternal illnesses were then included among the controlling factors. When this was done the first trimester x-rays were 2.73 times as effective as later exposures. First trimester x-rays were most strongly associated with the cancers which were diagnosed between 4 and 5 years of age. Although the number of films had no detectable effect upon relative risk calculated over all ages, multiple exposures were demonstrably associated with early age at diagnosis. (author)

  6. Risk evaluation of cosmic-ray exposure in long-term manned space mission

    International Nuclear Information System (INIS)

    Fujitaka, Kazunobu; Majima, Hideyuki; Ando, Koichi; Yasuda, Hiroshi; Suzuki, Masao

    1999-03-01

    Long-term manned space missions are planned to be implemented within the first two decades of the 21st century. The International Space Station (ISS) will be ready to run, and a plan to visit Mars is also under way. Humans will live in space for long periods of time and we are planning to do experiments in space to examine various aspects of space science. The main risk in long-term manned space missions is large exposure to space radiation. Human safety must be ensured in space where exposure to cosmic rays is almost 1 mSv a day. As such missions will inevitably result in significant exposure for astronauts, there is increasing need to protect them adequately based on both physical and biological knowledge. A good method to evaluate realistic risk associated with space missions will be in urgent demand. At the National Institute of Radiological Sciences (NIRS), Chiba, Japan, a research institutes of the Science Technology Agency of Japan, high energy cosmic radiation can be simulated only with heavy ion irradiation accelerated by the particle accelerator, Heavy Ion Medical Accelerator (HIMAC). Research to evaluate risk of space radiation, including physical measurement techniques, protective effects, biological effects and risk adjustment, aging, neuronal cell damage and cancer risk are undergoing. We organized a workshop of the latest topics and experimental results of physics and biology related to space radiation supported by Japan Science and Technology Corporation (JST). This workshop was held as a satellite meeting associated with the 32nd Committee on Space Research (COSPAR) Scientific Assembly (Nagoya, July 12-19th, 1998). This volume is an extended proceedings of the workshop. The proceedings contain six main subjects covering the latest information on Risk Evaluation of Cosmic-Ray Exposure in Long-Term Manned Space Mission'. 1. Risk Estimation of Heavy Ion Exposure in Space. 2. Low Dose-Rate Effects and Microbeam-Related Heavy Ions. 3. Chromosome and

  7. Influence of dose rate on the induction of simple and complex chromosome exchanges by gamma rays.

    Science.gov (United States)

    Loucas, Bradford D; Eberle, Richard; Bailey, Susan M; Cornforth, Michael N

    2004-10-01

    Single-color painting of whole chromosomes, or protocols in which only a few chromosomes are distinctively painted, will always fail to detect a proportion of complex exchanges because they frequently produce pseudosimple painting patterns that are indistinguishable from those produced by bona fide simple exchanges. When 24-color multi-fluor FISH (mFISH) was employed for the purpose of distinguishing (truly) simple from pseudosimple exchanges, it was confirmed that the acute low-LET radiation dose-response relationship for simple exchanges lacked significant upward curvature. This result has been interpreted to indicate that the formation of simple exchanges requires only one chromosome locus be damaged (e.g. broken) by radiation to initiate an exchange-not two, as classical cytogenetic theory maintains. Because a one-lesion mechanism implies single-track action, it follows that the production of simple exchanges should not be influenced by changes in dose rate. To examine this prediction, we irradiated noncycling primary human fibroblasts with graded doses of (137)Cs gamma rays at an acute dose rate of 1.10 Gy/min and compared, using mFISH, the yield of simple exchanges to that observed after exposure to the same radiation delivered at a chronic dose rate of 0.08 cGy/min. The shape of the dose response was found to be quasi-linear for both dose rates, but, counter to providing support for a one-lesion mechanism, the yield of simple aberrations was greatly reduced by protracted exposure. Although chronic doses were delivered at rates low enough to produce damage exclusively by single-track action, this did not altogether eliminate the formation of complex aberrations, an analysis of which leads to the conclusion that a single track of low-LET radiation is capable of inducing complex exchanges requiring up to four proximate breaks for their formation. For acute exposures, the ratio of simple reciprocal translocations to simple dicentrics was near unity.

  8. Outdoor γ-ray dose rate in Shariki Village and environmental factors affecting outdoor γ-ray dose rate in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2000-01-01

    Previously, we surveyed the outdoor γ-ray dose rate throughout Aomori Prefecture from 1992 to 1995, and found an annual mean dose rate of 51 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Shariki Village. Glass dosemeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the village. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosemeters showed that the γ-ray dose rates in Shariki Village varied from 49 to 55 nGy h -1 . Although the dose rates were generally higher than the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the village. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in the IES site. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 27 nGy h -1 and higher than when no precipitation was sensed (25 nGy h -1 ). (author)

  9. Outdoor γ-ray dose rate in Mutsu city and environmental factors affecting outdoor γ-ray dose rate in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2001-01-01

    Previously, we surveyed outdoor γ-ray dose rates throughout Aomori Prefecture from 1992 to 1995, and found a mean annual dose rate of 28 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Mutsu City. Glass dosemeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the city. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosemeters showed that the γ-ray dose rates in Mutsu City varied from 17 to 32 nGy h -1 . Although the dose rates were almost the same as the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the local ground. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in the IES site. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 26 nGy h -1 and higher than when no precipitation was sensed (24 nGy h -1 ). (author)

  10. X-ray detector for automatic exposure control using ionization chamber filled with xenon gas

    CERN Document Server

    Nakagawa, A; Yoshida, T

    2003-01-01

    This report refers to our newly developed X-ray detector for reliable automatic X-ray exposure control, which is to be widely used for X-ray diagnoses in various clinical fields. This new detector utilizes an ionization chamber filled with xenon gas, in contrast to conventional X-ray detectors which use ionization chambers filled with air. Use of xenon gas ensures higher sensitivity and thinner design of the detector. The xenon gas is completely sealed in the chamber, so that the influence of the changes in ambient environments is minimized. (author)

  11. Fieldable computer system for determining gamma-ray pulse-height distributions, flux spectra, and dose rates from Little Boy

    International Nuclear Information System (INIS)

    Moss, C.E.; Lucas, M.C.; Tisinger, E.W.; Hamm, M.E.

    1984-01-01

    Our system consists of a LeCroy 3500 data acquisition system with a built-in CAMAC crate and eight bismuth-germanate detectors 7.62 cm in diameter and 7.62 cm long. Gamma-ray pulse-height distributions are acquired simultaneously for up to eight positions. The system was very carefully calibrated and characterized from 0.1 to 8.3 MeV using gamma-ray spectra from a variety of radioactive sources. By fitting the pulse-height distributions from the sources with a function containing 17 parameters, we determined theoretical repsonse functions. We use these response functions to unfold the distributions to obtain flux spectra. A flux-to-dose-rate conversion curve based on the work of Dimbylow and Francis is then used to obtain dose rates. Direct use of measured spectra and flux-to-dose-rate curves to obtain dose rates avoids the errors that can arise from spectrum dependence in simple gamma-ray dosimeter instruments. We present some gamma-ray doses for the Little Boy assembly operated at low power. These results can be used to determine the exposures of the Hiroshima survivors and thus aid in the establishment of radation exposure limits for the nuclear industry

  12. Exposure measurement in the neighboring hospital beds during an x-ray procedure in hospitalization unit

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Rafael E.; Capeleti, Felipe F.; Cabete, Henrique V., E-mail: rafael.goto@fcmsantacasasp.edu.br, E-mail: felipe.capeleti@fcmsantacasasp.edu.br, E-mail: henrique@gmpbrasil.com.br [Faculdade de Ciencias Medicas da Santa Casa Sao Paulo, SP (Brazil); GMP Consultoria em Radioprotecao e Fisica Medica e Assessoria LTDA, Sao Paulo, SP (Brazil)

    2017-11-01

    There are lots of discussion about the exposure in hospitalization units in Brazil, especially around labor legislation and economic advantages of unhealthiness. With the attention focused on hospitalized patients, there were measured the exposure in neighboring beds of the patient submitted to an X-ray procedure with a mobile X-ray system that could be used to illustrate the discussion with consistent values. The most common X-ray procedure made in hospitalization units are chests images with techniques between 70 to 120 kV and 5 to 20 mAs. The measurement was made during routine exposure and simulations using a scattering phantom with Radcal AccuPro electrometer and 1800cc ionization chamber in a private hospital and a philanthropic hospital, both in Sao Paulo, Brazil. The ionization chambers are placed at 2 meters distance of the patient exposed of both sides during the routine procedure. During the simulation, a nylon phantom of 20 centimeters thick and 30 x 30 cm² size was placed on the bed, a typical exposure technique was used and the exposure was measured surrounding the phantom at 0.6, 1.0 and 2.0 meters distance for scattered radiation characterization. Initial results showed that the neighboring exposure at about 2 meters distance from the exposed patient bed have low values, even when exposure is integrated during the length of hospital stay. Therefore, the exposure in hospitalization units are very low compared to the exams doses. (author). (author)

  13. [Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation].

    Science.gov (United States)

    Olszewski, Jerzy; Wrzesień, Małgorzata

    2017-06-27

    The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491-496. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  14. X-ray diagnostic installation with an image intensifier TV chain and a dose rate control device

    Energy Technology Data Exchange (ETDEWEB)

    Duemmling, K; Schott, O

    1977-04-28

    The person performing the examination can key up the dose rate briefly via the X-ray tube current, e.g., if the movement of a contrast medium is to be observed on the video screen and only certain phases in this movement, which are of diagnostic significance, are to be viewed more closely. The upward change necessary to reduce quantum noise by a certain factor is made by means of a switch. This at the same time results in a reduction of brightness (over-exposure) of the X-ray image on the video screen by actuating an aperture system between the image intensifier, and the TV camera. To prevent the X-ray tube from being overloaded during key-up of the dose rate, a time limit switch is installed in the control system.

  15. Effect of infrared and X-ray radiation on thymus cells and the rate of growth of Ehrlich carcinoma.

    Science.gov (United States)

    Dyukina, A R; Zaichkina, S I; Rozanova, O M; Aptikaeva, G F; Romanchenko, S P; Sorokina, S S

    2012-09-01

    We studied the effect of infrared light with a wavelength of 850 nm and modulated frequency of 101 Hz and X-ray radiation on the induction of cross-adaptive and radiation responses in the thymus and on the rate of tumor growth in mice in vivo. Preliminary exposure to infrared and X-ray radiation was shown to result in recovery in thymus weight after irradiation in a dose of 1.5 Gy and also inhibited the growth rate of Ehrlich carcinoma. These data attest to common mechanisms of the adaptive response induced by infrared and X-ray radiation in mice. Infrared light can be used as an adaptogen to adapt the animals to adverse factors.

  16. Determination of energy absorbed during X-ray exposure of the forearm by means of thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Hofmann, E.

    1982-01-01

    LiF dose meters were used to determine radiation doses in conventional X-ray diagnostic pictures of the forearm. The paper describes a method for determining integral doses by using these dose meters. It describes in detail how a phantom forearm apt for the purpose is to be made. In the Federal Republic of Germany, malignant growth incidence due to X-ray pictures of the forearm is enhanced by about .01 cases each year. The malignant growth incidence rate caused by X-ray diagnostic measures is low. It is therefore generally justified to neglect limbs in exemplary studies of radiation exposure. All calculations and considerations took into account that all possible radiation protection measures have been duly applied. (orig./DG) [de

  17. Observation of X-ray occupational exposure on psychological function of medical workers

    International Nuclear Information System (INIS)

    Gong Zhaolong; Li Xiuqin

    1988-01-01

    The present research is an attempt to study the psychological effects of long-term exposure to low-level X-ray on man. The subjects included 50 exposed people and 50 control. The battery of psychological tests consists of 10 subtests mainly involving memory and coordination ability. The results indicate that there are no statistical differences in all subtests between exposure and control group, but exposure group appears to be a little lower on most subtests about memory. With age, decline of psychological function is observed in all subtests in both groups. The subjects are further divided into three subgroups according to the number of X-ray exposed years. No statistical differences are found in all subgroups between exposure and control. Factor analysis has been made and two factors are obtained. factor 1 is mainly about speed of coordination, factor 2 is mainly about memory and attention. No statistical differences in factor scores are observed in all subgroups between exposure and control. Yet decline is found in factor 1 and factor 2 in both exposure and control groups with age. The results show that there is no significant effect of current dose level of X-ray exposure on human psychological function

  18. Determination of personnel exposures in the lower energy ranges of X-ray by photographic dosimeter

    International Nuclear Information System (INIS)

    Ha, C.W.; Kim, J.R.; Suk, K.W.

    1986-01-01

    This paper described an improved technical method required for proper evaluation of personnel exposures by means of the photographic dosimeter developed by KAERI in lower gamma or X-ray energy regions, with which response of the dosimeter varies significantly. With calibration of the dosimeter in the energy range from 30 to 300 keV, the beam spectrum was carefully selected and specified it adequately. The absorber combinations and absorber thickness used to obtain the specified X-ray spectra from a constant potential X-ray machine were determined theoretically and also experimentally. A correlation between the density and exposure for the four separate energies, such as 49 keV eff , 154 keV eff 250 keV eff and 662 keV, is experimentally determined. As a result, it can be directly evaluated the exposure from the measured response of dosimeter. (Author)

  19. Patient dose evaluations from medical X-ray exposure in Italy: an analysis of next data

    International Nuclear Information System (INIS)

    Marchetti, A.; Paganini, F.M.; Susanna, A.

    1980-01-01

    NEXT (Nationwide Evaluation of X-ray Trends) is a program for the evaluation of patient exposure in X-ray diagnostic tests. The program is aimed at reducing patient exposure by pin-pointing poor radiological techniques and improving them. CNEN (Comitato Nazionale per l'Energia Nucleare) and ISS (Istituto Superiore di Sanita) have been developing such a program in Italy since 1976. Up to now two regional administrations applied the method and regional operators collected the needed data in all the medical institutions in their areas. The results show a wide spread of values for all the parameters studied in the 12 X-ray projections selected. Gonad dose and skin entrance exposure were found to be spread over a range up to about two orders of magnitude. (H.K.)

  20. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  1. Phototimer for automatic control of x-ray exposure, PT-20A

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, H; Itoh, K; Ogura, I; Yasuhara, H; Sugimoto, H [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1979-02-01

    The phototimer as an exposure control device is now required to have higher accuracy and wider range of control to comply with the recent trends of x-ray diagnosis, such as toward short-time exposure due to increased output power of x-ray apparatus and toward one-man operation. In order to meet the requirement, the x-ray characteristics of the components of the phototimer have been examined, and computer simulation of x-ray spectra and dynamic characteristics of every component have been investigated, in pursuit of the essential characters of phototimers. On the basis of these analytical investigations, the phototimer PT-20A is so designed as to compensate for density deviation under various kVp and object thickness: uniform density has been obtained under practical radiographic conditions.

  2. Cosmic-ray exposure ages of six chondritic Almahata Sitta fragments

    Science.gov (United States)

    Riebe, M. E. I.; Welten, K. C.; Meier, M. M. M.; Wieler, R.; Barth, M. I. F.; Ward, D.; Laubenstein, M.; Bischoff, A.; Caffee, M. W.; Nishiizumi, K.; Busemann, H.

    2017-11-01

    The Almahata Sitta strewn field is dominated by ureilites, but contains a large fraction of chondritic fragments of various types. We analyzed stable isotopes of He, Ne, Ar, Kr, and Xe, and the cosmogenic radionuclides 10Be, 26Al, and 36Cl in six chondritic Almahata Sitta fragments (EL6 breccia, EL6, EL3-5, CB, LL4/5, R-like). The cosmic-ray exposure (CRE) ages of five of the six samples have an average of 19.2 ± 3.3 Ma, close to the average of 19.5 ± 2.5 Ma for four ureilites. The cosmogenic radionuclide concentrations in the chondrites indicate a preatmospheric size consistent with Almahata Sitta. This corroborates that Almahata Sitta chondrite samples were part of the same asteroid as the ureilites. However, MS-179 has a lower CRE age of 11.0 ± 1.4 Ma. Further analysis of short-lived radionuclides in fragment MS-179 showed that it fell around the same time, and from an object of similar size as Almahata Sitta, making it almost certain that MS-179 is an Almahata Sitta fragment. Instead, its low CRE age could be due to gas loss, chemical heterogeneity that may have led to an erroneous 21Ne production-rate, or, perhaps most likely, MS-179 could represent the true 4π exposure age of Almahata Sitta (or an upper limit thereof), while all other samples analyzed so far experienced exposure on the parent body of similar lengths. Finally, MS-179 had an extraordinarily high activity of neutron-capture 36Cl, 600 dpm kg-1, the highest activity observed in any meteorite to date, related to a high abundance of the Cl-bearing mineral lawrencite.

  3. High precision instrumentation for measuring the true exposure time in diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Silva, Danubia B.; Santos, Marcus A.P.; Barros, Fabio R.; Santos, Luiz A.P.

    2013-01-01

    One of the most important physical quantities to be evaluated in diagnostic radiology is the radiation exposure time experimented by the patient during the X-ray examination. IAEA and WHO organizations have suggested that any country must create a quality surveillance program to verify if each type of ionizing radiation equipment used in the hospitals and medical clinics are in conformity with the accepted uncertainties following the international standards. The purpose of this work is to present a new high precision methodology for measuring true exposure time in diagnostic X-ray examinations: pulsed, continuous or digital one. An electronic system named CronoX, which will be soon registered at the Brazilian Patent Office (INPI), is the equipment that provides such a high precision measurement. The principle of measurement is based on the electrical signal captured by a sensor that enters in a regeneration amplifier to transform it in a digital signal, which is treated by a microprocessor (uP). The signal treatment results in a two measured times: 1) T rx , the true X-ray exposure time; 2) T nx , the time in which the X-ray machine is repeatedly cut off during the pulsed irradiation and there is no delivery dose to the patient. Conventional Polymat X-ray equipment and dental X-ray machines were used to generate X-ray photons and take the measurements with the electronic systems. The results show that such a high precision instrumentation displays the true exposure time in diagnostic X-ray examinations and indicates a new method to be purposed for the quality surveillance programs in radiology. (author)

  4. The primary exposure standard of ENEA for medium energy X-ray: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a medium energy X-ray free-air chamber used, as primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the Enea in Italy. The main features of an X-ray facility for the production of radiation between 40 KeV and 400 KeV are also described. The measurements procedures are then analyzed with respect to the realization of the exposure unit in the relevant energy range. Finally the results of some international comparisons are reported

  5. Influence of chronic x-ray exposure on adrenal glucocorticoid function and adrenocorticocyte membrane potential

    International Nuclear Information System (INIS)

    Gorban', Je.M.; Topol'nikova, N.V.

    1998-01-01

    The peculiarities of adrenal glucocorticoid function and membrane potential (MP) of zona fasciculata adrenocorticocyte (ACC) in rats after chronic x-ray exposure was studied. The changes of adrenal glucocorticoid function caused by chronic x-ray exposure within a relatively small period of irradiation (1.5 months) are obscure and manifest themselves only at physiological load. With the prolongation of the period (8 and 15 months), more considerable inhibition of the adrenal glucocorticoid function and disturbances in the membrane mechanisms of ACC MP level regulation are revealed

  6. Radiation exposure in X-ray angiography and comparisons between digital and conventional methods of imaging

    International Nuclear Information System (INIS)

    Schaberg, J.

    1987-01-01

    The more recent developments and techniques in the field of angiography are examined for associated radiation exposure risks for patients and investigators and then compared to the conventional methods of angiography. It could be shown that digital subtraction angiography is generally associated with a lesser risk of somatic exposure of the patient, provided that the equipment used offers an adjustable useful-beam range and focus. The fact that above-table X-ray tubes are now generally replaced with X-ray systems installed under the examination table permits the relatively high doses, to which investigators are exposed during angiography, to be reduced by a factor of 3. (DG) [de

  7. An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

    International Nuclear Information System (INIS)

    Polee, C; Chankow, N; Srisatit, S; Thong-Aram, D

    2015-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking information of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a small detector. Application software was developed for Android mobile phone to remotely control the device and to display counting data via Bluetooth communication. Prior to film exposure, the device is placed behind a specimen to measure transmitted intensity which is inversely proportional to the exposure. Unlike in using the conventional exposure curve, correction factors for source decay, source-to- film distance, specimen thickness and kind of material are not needed. The developed technique and device make radiographic process economic, convenient and more reliable. (paper)

  8. Differences in responses to X-ray exposure between osteoclast and osteoblast cells

    International Nuclear Information System (INIS)

    Zhang, Jian; Wang, Ziyang; Wu, Anqing; Nie, Jing; Pei, Hailong; Hu, Wentao; Wang, Bing; Shang, Peng; Li, Bingyan; Zhou, Guangming

    2017-01-01

    Radiation-induced bone loss is a potential health concern for cancer patients undergoing radiotherapy. Enhanced bone resorption by osteoclasts and decreased bone formation by osteoblasts were thought to be the main reasons. In this study, we showed that both pre-differentiating and differentiating osteoclasts were relatively sensitive to X-rays compared with osteoblasts. X-rays decreased cell viability to a greater degree in RAW264.7 cells and in differentiating cells than than in osteoblastic MC3T3-E1 cells. X-rays at up to 8 Gy had little effects on osteoblast mineralization. In contrast, X-rays at 1 Gy induced enhanced osteoclastogenesis by enhanced cell fusion, but had no effects on bone resorption. A higher dose of X-rays at 8 Gy, however, had an inhibitory effect on bone resorption. In addition, actin ring formation was disrupted by 8 Gy of X-rays and reorganized into clusters. An increased activity of Caspase 3 was found after X-ray exposure. Actin disorganization and increased apoptosis may be the potential effects of X-rays at high doses, by inhibiting osteoclast differentiation. Taken together, our data indicate high radiosensitivity of osteoclasts. X-ray irradiation at relatively low doses can activate osteoclastogenesis, but not osteogenic differentiation. The radiosensitive osteoclasts are the potentially responsive cells for X-ray-induced bone loss.

  9. Comparison of cytogenetic effects after occupational exposure to X-rays with those after foetal pelvimetric exposure

    International Nuclear Information System (INIS)

    Kirsch-Volders, M.; Poma, K.; Verschaeve, L.; Hens, L.; Susanne, C.; Elegem, P. van

    1978-01-01

    In utero acute low-level exposure to X-rays (300 to 350 mrads) induces a significant increase of band-loss in G-trypsin banded chromosomes of umbilical lymphocytes. Results, however, have to be confirmed by dose-effect relation studies and analysis with spectro-photometric scanning of deleted chromosomes. The same in utero exposure induces a significant dissociaton of chromosome pair 13 as revealed by centromere-centromere, angle and association tendency analysis of chromosome distribution in comparison with a control group. Occupational chronic low-level exposure to ionizing radiation does not modify significantly the amount of SCE in lymphocytes of peripheral blood. However, an analysis of centromere-centromere distances, angle values and associaton tendencies of the different chromosome combinations clearly shows an association of chromosome pair 12-16 after exposure to ionizing radiation. It is difficult to assess the exact biological importance of the observed chromosome modifications. However, referring to the already described dissociation of human acrocentric chromosomes after in vivo exposure to low levels of phenyl Hg acetate or inorganic Pb, the chromosome distribution seems not to be significantly disturbed by chronic or acute low-level exposure to ionizing radiation. (author)

  10. Radiation exposure and image quality in x-Ray diagnostic radiology physical principles and clinical applications

    CERN Document Server

    Aichinger, Horst; Joite-Barfuß, Sigrid; Säbel, Manfred

    2012-01-01

    The largest contribution to radiation exposure to the population as a whole arises from diagnostic X-rays. Protecting the patient from radiation is a major aim of modern health policy, and an understanding of the relationship between radiation dose and image quality is of pivotal importance in optimising medical diagnostic radiology. In this volume the data provided for exploring these concerns are partly based on X-ray spectra, measured on diagnostic X-ray tube assemblies, and are supplemented by the results of measurements on phantoms and simulation calculations.

  11. Exposure doses of the patient and the medical staff during urological X-ray examens

    International Nuclear Information System (INIS)

    Vogel, H.; Loehr, H.; Haug, P.; Schuett, B.

    1977-01-01

    During 32 intravenous urografies and 48 angiografies of the kidney and the suprarenal glands the X-ray doses at the patient's skin and gonades were determined. During the angiografies the doses were mesured at the hands. the gonades and the front (eyes) of the medical staff. The results are discussed. Because the X-ray doses are relatively high, the number of the pictures and the exposure time is to be reduced to the minimum. Clinical experience and special knowledge is the best X-ray protection. (orig.) [de

  12. Color change of gemstones by exposure to gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Giovanna L.C. de; Lameiras, Fernando S., E-mail: giovannalarissa17@hotmail.com, E-mail: fsl@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    A gem is appreciated by collectors and, when polished, widely used for jewelry manufacturing. For example, when quartz naturally or artificially acquires a color it becomes a gemstone (smoky quartz, morion, citrine, amethyst, or prasyolite). The presence of chromophore elements in a quartz sample was analysed by Fourier transform infrared spectrometry (FTIR). With a semi-quantitative analysis of the absorption FTIR spectra, it was possible to predict if colorless quartz has the potential to develop color when exposed to ionizing radiation and heat. Specific absorption bands show the presence of chromophore elements in quartz such as aluminum, iron, hydrogen, sodium, or lithium. Considering the ratio of the heights of the absorption bands of these elements, it was possible to predict the color quartz can develop. Samples of irradiated dark and light violet fluorites were analyzed by FTIR and energy-dispersive X-rays spectroscopy. The light violet samples has higher content of calcium relative to fluorine, as well higher content of hydroxyl, probably replacing fluorine in crystal lattice. Hydroxyls cannot be precursors of F color centers, which are the cause of violet color in fluorite, explaining the light violet color of hydroxyl-rich samples. (author)

  13. Color change of gemstones by exposure to gamma rays

    International Nuclear Information System (INIS)

    Lima, Giovanna L.C. de; Lameiras, Fernando S.

    2015-01-01

    A gem is appreciated by collectors and, when polished, widely used for jewelry manufacturing. For example, when quartz naturally or artificially acquires a color it becomes a gemstone (smoky quartz, morion, citrine, amethyst, or prasyolite). The presence of chromophore elements in a quartz sample was analysed by Fourier transform infrared spectrometry (FTIR). With a semi-quantitative analysis of the absorption FTIR spectra, it was possible to predict if colorless quartz has the potential to develop color when exposed to ionizing radiation and heat. Specific absorption bands show the presence of chromophore elements in quartz such as aluminum, iron, hydrogen, sodium, or lithium. Considering the ratio of the heights of the absorption bands of these elements, it was possible to predict the color quartz can develop. Samples of irradiated dark and light violet fluorites were analyzed by FTIR and energy-dispersive X-rays spectroscopy. The light violet samples has higher content of calcium relative to fluorine, as well higher content of hydroxyl, probably replacing fluorine in crystal lattice. Hydroxyls cannot be precursors of F color centers, which are the cause of violet color in fluorite, explaining the light violet color of hydroxyl-rich samples. (author)

  14. Hygiene implications associated with x-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients, then a skeleton encased in plastic, was instrumented with LiF thermoluminescent dosimeters to quantify radiation exposures delivered from full-face diagnostic dental x-rays. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices

  15. Estimating Exchange Rate Exposure over Various Return Horizons: Focusing on Major Countries in East Asia

    Directory of Open Access Journals (Sweden)

    Jeong Wook Lee

    2016-12-01

    Full Text Available In this paper, we estimate the exchange rate exposure, indicating the effect of exchange rate movements on firm values, for a sample of 1,400 firms in seven East Asian countries. The exposure estimates based on various exchange rate variables, return horizons and a control variable are compared. A key result from our analysis is that the long term effect of exchange rate movements on firm values is greater than the short term effect. And we find very similar results from using other exchange rate variables such as the U.S. dollar exchange rate, etc. Second, we add exchange rate volatility as a control variable and find that the extent of exposure is not much changed. Third, we examine the changes in exposure to exchange rate volatility with an increase in return horizon. Consequently the ratio of firms with significant exposures increases with the return horizons. Interestingly, the increase of exposure with the return horizons is faster for exposure to volatility than for exposure to exchange rate itself. Taken as a whole, our findings suggest that the so-called "exposure puzzle" may be a matter of the methodology used to measure exposure.

  16. Occupational exposure of medical staff due to diagnostic X-ray examinations in veterinary medicine

    International Nuclear Information System (INIS)

    Mergel, E.; Feige, S.; Haeusler, U.

    2007-01-01

    The implementation of the Council directive 96/29 EURATOM and the corresponding national Radiation Protection Ordinance and the X-ray Protection Ordinance coming subsequently into effect led to a changed situation regarding the occupational radiation protection in the medical sector. To reduce the occupational exposure of veterinarians and assisting staff in veterinary radiography is particularly challenging as, in opposite to human radiological examination, the presence of staff is indispensable to restrain the patient. Beyond that the relevant literature reports about too high and/or about unnecessary radiation exposures. To gain a comprehensive knowledge upon the possible exposure of involved staff, the variety of typical examination methods in veterinary clinics and at practitioners had been investigated during the daily routine. Dose measurements were performed for different employees during the examinations taking into account several places of exposure (lens, thyroid, chest, hand, gonad, and feet). Veterinary X-ray diagnostic examinations for pets as well as in equine radiography had been accounted for this study. In total, 101 examination methods, 4.484 accompanied examinations and 53.892 single dose readings resulted in a reliable statistical base to set up a 'Job-Exposure-Matrix' allowing the dose assessment for a variable number and kind of examinations. The 'Job-Exposure-Matrix' is believed to be a useful tool for optimization of occupational radiation exposure of veterinarians by appraising the height of a possible dose, forcing a review of the status quo and triggering the improvement of personal protection by establishing adequate measures. (orig.)

  17. Radium equivalent activity of building materials and gamma ray dose rates in ordinary houses of Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Campos, M.P.; Pecequilo, B.R.S.

    1994-01-01

    The external radiation exposure from natural radioactivity represents, approximately, 50% of the average annual dose caused to the human body by all natural and artificial radiation sources. Natural radioactivity in building materials is the most important source of external radiation exposure in dwellings because of the gamma rays emitted from potassium 40 and member of the uranium 238 and thorium 232 decay chains. Concrete is one of the most potential sources of elevated radiation exposure, however, little is known about the natural radioactivity of Brazilian construction materials. A study to predict the exposure rates of several ordinary houses built almost of concrete, consisting of 38 samples of 6 different materials was conducted by using high resolution gamma-ray spectrometry. The radium equivalent activity was calculated for all 38 samples in order to compare the specific activities of the construction materials containing different amounts of radium, thorium, and potassium. The effective dose rate due to the indoor gamma radiation from the building materials was performed following the 1988 UNSCEAR procedures

  18. Annama H chondrite-Mineralogy, physical properties, cosmic ray exposure, and parent body history

    Czech Academy of Sciences Publication Activity Database

    Kohout, Tomáš; Haloda, J.; Halodová, P.; Meiner, M. M. M.; Maden, C.; Busemann, H.; Laubenstein, M.; Caffee, M. W.; Welten, K.C.; Hopp, J.; Trieloff, M.; Mahajan, R. R.; Naik, S.; Trigo-Rodríguez, J.M.; Moyano-Cambero, C. E.; Oshtrakh, M. I.; Maksimova, A. A.; Chukin, A. V.; Semionkin, V. A.; Karabanalov, M. S.; Felner, I.; Petrova, E. V.; Brusnitsyna, E. V.; Grokhovsky, V. I.; Yakovlev, G. A.; Gritsevich, M.; Lyytinen, E.; Moilanen, J.; Kruglikov, N. A.; Ishchenko, A. V.

    2017-01-01

    Roč. 52, č. 8 (2017), s. 1525-1541 ISSN 1086-9379 Institutional support: RVO:67985831 Keywords : Annama * chondrite * cosmic-ray exposure * radionuclide Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 2.391, year: 2016

  19. Cost Benefit Optimization of the Israeli Medical Diagnostic X-Ray Exposure

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Shlesinger, T.; Shani, G.; Kushilevsky, A.

    1999-01-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. A preliminary survey was carried out during 1997 on 3 major Israeli hospitals in order to assess the extent of exposure of the population to medical x-rays (1). The survey has found that the annual collective dose of the Israeli population to x-ray medical imaging procedures (excluding radio-therapy) is about 7,500 Man-Sv. The results of the survey were analyzed in order to. 1. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of the Israeli patients under x-ray procedures. 2. Establish a set of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. . Establish a number of basic rules to be utilized by health policy makers in Israel. Based on the ICRP-60 linear model risk assessments (2), the extent of the annual risk arising A.om the 7,500 Man-Sv medical x-ray collective dose in Israel has been found to be the potential addition of 567 cancer cases per year, 244 of which to be fatal, and a potential additional birth of 3-4 children with severe genetic damage per year. This assessment take into account the differential risk and the collective dose according to the age distribution in the Israeli exposed population, and excludes patients with chronic diseases

  20. The rate of DNA synthesis in normal human and ataxia telangiectasia cells after exposure to X-irradiation

    International Nuclear Information System (INIS)

    Wit, J. de; Bootsma, D.; Jaspers, N.G.J.; Rijksverdedigingsorganisatie TNO, Rijswijk

    1981-01-01

    The rate of DNA synthesis was studied in normal cell strains and in strains from patients suffering from the inherited disorder ataxia telangiectasia (AT). After exposure to relatively low doses of oxic X-rays (0- 4 krad) DNA synthesis was depressed in AT cell strains to a significantly lesser extent than in normal cells. This response was observed in both an excision-deficient and an excision-proficient strain. In contrast, there was no difference in DNA-synthesis inhibition between AT and normal cells after UV exposure. After X-irradiation of cells from patients with xeroderma pigmentosum, both complementation group A and XP variants, the observed rate of DNA synthesis was equal to that in normal cells. An exception was the strain XP3BR which has been shown to be X-ray-sensitive. This strain exhibited diminished DNA synthesis inhibition after X-ray doses below 1 krad. These data suggest a relationship between hypersensitivity to X-rays and diminished depression of DNA synthesis. (orig.)

  1. Evaluation of selected parameters on exposure rates in Westinghouse designed nuclear power plants

    International Nuclear Information System (INIS)

    Bergmann, C.A.

    1989-01-01

    During the past ten years, Westinghouse under EPRI contract and independently, has performed research and evaluation of plant data to define the trends of ex-core component exposure rates and the effects of various parameters on the exposure rates. The effects of the parameters were evaluated using comparative analyses or empirical techniques. This paper updates the information presented at the Fourth Bournemouth Conference and the conclusions obtained from the effects of selected parameters namely, coolant chemistry, physical changes, use of enriched boric acid, and cobalt input on plant exposure rates. The trends of exposure rates and relationship to doses is also presented. (author)

  2. THE IMPLICATIONS OF A HIGH COSMIC-RAY IONIZATION RATE IN DIFFUSE INTERSTELLAR CLOUDS

    International Nuclear Information System (INIS)

    Indriolo, Nick; Fields, Brian D.; McCall, Benjamin J.

    2009-01-01

    Diffuse interstellar clouds show large abundances of H + 3 which can only be maintained by a high ionization rate of H 2 . Cosmic rays are the dominant ionization mechanism in this environment, so the large ionization rate implies a high cosmic-ray flux, and a large amount of energy residing in cosmic rays. In this paper, we find that the standard propagated cosmic-ray spectrum predicts an ionization rate much lower than that inferred from H + 3 . Low-energy (∼10 MeV) cosmic rays are the most efficient at ionizing hydrogen, but cannot be directly detected; consequently, an otherwise unobservable enhancement of the low-energy cosmic-ray flux offers a plausible explanation for the H + 3 results. Beyond ionization, cosmic rays also interact with the interstellar medium by spalling atomic nuclei and exciting atomic nuclear states. These processes produce the light elements Li, Be, and B, as well as gamma-ray lines. To test the consequences of an enhanced low-energy cosmic-ray flux, we adopt two physically motivated cosmic-ray spectra which by construction reproduce the ionization rate inferred in diffuse clouds, and investigate the implications of these spectra on dense cloud ionization rates, light-element abundances, gamma-ray fluxes, and energetics. One spectrum proposed here provides an explanation for the high ionization rate seen in diffuse clouds while still appearing to be broadly consistent with other observables, but the shape of this spectrum suggests that supernovae remnants may not be the predominant accelerators of low-energy cosmic rays.

  3. Scaling in situ cosmogenic nuclide production rates using analytical approximations to atmospheric cosmic-ray fluxes

    Science.gov (United States)

    Lifton, Nathaniel; Sato, Tatsuhiko; Dunai, Tibor J.

    2014-01-01

    Several models have been proposed for scaling in situ cosmogenic nuclide production rates from the relatively few sites where they have been measured to other sites of interest. Two main types of models are recognized: (1) those based on data from nuclear disintegrations in photographic emulsions combined with various neutron detectors, and (2) those based largely on neutron monitor data. However, stubborn discrepancies between these model types have led to frequent confusion when calculating surface exposure ages from production rates derived from the models. To help resolve these discrepancies and identify the sources of potential biases in each model, we have developed a new scaling model based on analytical approximations to modeled fluxes of the main atmospheric cosmic-ray particles responsible for in situ cosmogenic nuclide production. Both the analytical formulations and the Monte Carlo model fluxes on which they are based agree well with measured atmospheric fluxes of neutrons, protons, and muons, indicating they can serve as a robust estimate of the atmospheric cosmic-ray flux based on first principles. We are also using updated records for quantifying temporal and spatial variability in geomagnetic and solar modulation effects on the fluxes. A key advantage of this new model (herein termed LSD) over previous Monte Carlo models of cosmogenic nuclide production is that it allows for faster estimation of scaling factors based on time-varying geomagnetic and solar inputs. Comparing scaling predictions derived from the LSD model with those of previously published models suggest potential sources of bias in the latter can be largely attributed to two factors: different energy responses of the secondary neutron detectors used in developing the models, and different geomagnetic parameterizations. Given that the LSD model generates flux spectra for each cosmic-ray particle of interest, it is also relatively straightforward to generate nuclide-specific scaling

  4. Dental X-ray diagnostic facility with means to choose the time of exposure

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H; Grassme, U

    1978-02-16

    Equipment for dental X-ray diagnostics with automatic exposure control. In the patient's mouth there is arranged a film carrier containing in a pocket a dental X-ray film. A detector-transmitter assembly touches the pocket. It reacts to the density of the film and wireless transmits a signal to an antenna. This antenna is connected to a receiver shutting off the high voltage of the X-ray tube by means of a circuit if a desired dose value is reached. The detector-transmitter unit is an integrated component. It has got a luminescent layer with a light-sensitive detector or a detector directly sensitive to X-rays.

  5. Outdoor γ-ray dose rate in Ajigasawa Town and environmental factors affecting it in IES

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shunichi; Sakurai, Naoyuki; Koyama, Kenji

    1999-01-01

    We surveyed the outdoor γ-ray dose rate throughout Aomori Prefecture from 1991 to 1995, and found an annual mean dose rate of 46 nGy h -1 . Relatively high dose rates were also observed in several areas (municipalities) of the survey locations. In this study, we examined the detailed distribution of the γ-ray dose rate in one such high dose rate area, Ajigasawa Town. Glass dosimeters were used for the monitoring of cumulative γ-ray dose rate at 10 locations in the town. The dose rate from each radioactive nuclide in the ground at the monitoring locations was measured by using an in situ γ-ray spectrometer with a Ge detector. The results obtained with the glass dosimeters showed that the γ-ray dose rates in Ajigasawa Town varied from 48 to 57 nGy h -1 . Although the dose rates were generally higher than the mean dose in Aomori Prefecture (1992-1995), the rates were lower than other high dose rate areas which had already been measured. The in situ γ-ray spectrometry revealed that these relatively high dose rates were mainly caused by 40 K and Th series radionuclides in the town. The effect of meteorological conditions on the γ-ray dose rate was studied at a monitoring station in IES. The dose rate was continuously recorded by a DBM NaI(Tl) scintillation detector system. The mean dose rate obtained when precipitation was sensed was 27 nGy h -1 and higher than when no precipitation was sensed (23 nGy h -1 ). (author)

  6. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.

    Science.gov (United States)

    Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael

    2017-09-01

    Purpose  Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods  Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results  The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm 2 (flat panel detector systems: 155 cGy*cm 2 ; X-ray image intensifier: 175 cGy*cm 2 ). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm 2 ), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT - flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion  In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe

  7. On micro- and macrocirculatory effects of the whole body exposure to γ-rays in the rabbit

    International Nuclear Information System (INIS)

    Asano, Makishige; Ohkubo, Chiyoji; Chiba, Masashi

    1988-01-01

    Immediate and prolonged microcirculatory effects of varying single doses of the whole body exposure of γ-rays irradiation were studied by using the intravital-microscopy concurrently with macrocirculatory hematological determination in the healthy male rabbit. The intravital-microscopy applied to the subcutaneous microcirculatory system in a transparent round-table chamber, that has been installed in advance into the ear lobe, revealed that markedly increased intravascular adhesiveness of white blood cells (WBCs) and extensive stasis similar to the intravascular coagulation of red blood cells (RBCs) developed as immediate changes soon after the γ-rays irradiation regardless of difference of exposure doses such as 50, 250, 500 and 1000 R. Although these changes disappeared within 3 - 4 weeks in animals exposed to 50 R, they persisted throughout the whole experimental period of 4 weeks at higher doses of γ-rays and the extent of the persisting changes appeared to be dose-dependent. Similarly the macrocirculatory changes such as decreases in measurements of RBCs, WBCs, hematocrit values, hemoglobin concentrations, and platelet counts and increase in erythrocyte sedimentation rates were also noticed in a dose-dependent manner. (author)

  8. Combined exposure of ELF magnetic fields and X-rays increased mutant yields compared with X-rays alone in pTN89 plasmids

    International Nuclear Information System (INIS)

    Koyama, Shin; Nakahara, Takehisa; Sakurai, Tomonori; Komatsubara, Yoshiki; Miyakoshi, Junji; Isozumi, Yasuhito

    2005-01-01

    We have examined mutations in the supF gene carried by pTN89 plasmids in Escherichia coli (E. coli) to examine the effects of extremely low frequency magnetic fields (ELFMFs) and/or X-rays to the plasmids. The plasmids were subjected to sham exposure or exposed to an ELFMF (5 mT), with or without X-ray irradiation (10 Gy). For the combined treatments, exposure to the ELFMF was immediately before or after X-ray irradiation. The mutant fractions were 0.94 x 10 -5 for X-rays alone, 1.58 x 10 -5 for an ELFMF followed by X-rays, and 3.64 x 10 -5 for X-rays followed by an ELFMF. Increased mutant fraction was not detected following exposure to a magnetic field alone, or after sham exposure. The mutant fraction for X-rays followed by an ELFMF was significantly higher than those of other treatments. Sequence analysis of the supF mutant plasmids revealed that base substitutions were dominant on exposure to X-rays alone and X-rays plus an ELFMF. Several types of deletions were detected in only the combined treatments, but not with X-rays alone. We could not find any mutant colonies in sham irradiated and an ELFMF alone treatment, but exposure to ELFMFs immediately before or after X-ray irradiation may enhance the mutations. Our results indicate that an ELFMF increases mutation and alters the spectrum of mutations. (author)

  9. DIGITAL FLOOD INSURANCE RATE MAP DATABASE, RAY COUNTY, MISSOURI, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — The Digital Flood Insurance Rate Map (DFIRM) Database depicts flood risk information and supporting data used to develop the risk data. The primary risk...

  10. Micronucleus induction by repeated exposure of diagnostic X-ray on oral buccal mucosa

    International Nuclear Information System (INIS)

    Lohith Tejashvi, K.; Suchetha Kumari, N.; Shetty, Shishir Ram

    2012-01-01

    Radiography is the important diagnostic tools essential for diagnosis and planning of orthodontic treatment. X-ray is ionizing radiation which showed various effects include breaking the bond of biological molecules, inducing loss of ability of cell death, increases nuclear alterations. Micronuclei - x000D - (MN) are small chromatin bodies that appear in the cytoplasm by the - x000D - condensation of acrocentric chromosomal fragments or by whole chromosomes. This - x000D - is a sensitive indicator of genetic damage. - x000D - x000D - . To evaluate micronucleus induction by repeated exposure of diagnostic X-ray on human buccal cell. Methods: 25 patients who visiting to ABSMIDS, Department of Oral medicine and Radiology for dental checkup exposed to diagnostic X-ray more than 4 times have been selected for this study. The buccal cell for analysis was collected from the cheek mucosa by means of gentle scraping of epithelial using ice-cream sticks and placed in Buffer saline. This sample was smeared on glass slide and then fixed in methanol:glacial acetic acid (3:1). Air dried and stained with Giemsa for 15-25 minutes. Then 250 cells in each slides were analyzed under microscope and frequency of micronucleus was scored (n=4). Repeated X-ray exposed cells showed micronucleus (1.25%) and nuclear alteration (2.3%) compare to the control. Repeated X-ray exposure leads to induces detectable number of micronucleus and nuclear alterations. (author)

  11. Exchange Rate Exposures and Strategies of Industrial Companies: An Empirical Study

    DEFF Research Database (Denmark)

    Aabo, Tom

    2001-01-01

    This article investigates empirically the potential and actual exchange rate exposure strategies of industrial companies in relation to identifying and quantifying the neutral financial positions in an optimal hedging strategy.......This article investigates empirically the potential and actual exchange rate exposure strategies of industrial companies in relation to identifying and quantifying the neutral financial positions in an optimal hedging strategy....

  12. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    International Nuclear Information System (INIS)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S

    2006-01-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process

  13. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 373-1, Guseong-dong, Yuseong-dong, Daejeon (Korea, Republic of)

    2006-04-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process.

  14. X-ray exposure in utero and school performance: a population-based study of X-ray pelvimetry

    International Nuclear Information System (INIS)

    Nordenskjöld, A.C.; Palme, M.; Kaijser, M.

    2015-01-01

    Aim: To investigate the association between exposure to ionising radiation from pelvimetric examinations in utero and school performance. Material and methods: This was a population-based cohort study comprising 46,066 children born in the county of Östergötland, Sweden, from 1980 through 1990. Through record linkage between Swedish registers, children exposed in utero to X-ray pelvimetry examination were compared to other children born in the same county during the study period, as well as to their unexposed siblings. Outcome variable was primary school grades, expressed in centiles and calculated through linear regression. Results: In the univariate analysis, children exposed to X-ray pelvimetry in utero had higher school grades compared to unexposed children (point estimate 3 centiles, 95% confidence interval [CI]: 1.5 to 4.6). When sex, mother's education and income, birth order, and birth position were included in the analysis; however, the difference was reduced and the association was no longer statistically significant (PE 1.4, 95% CI: –0.1 to 2.8). Comparing exposed children with their siblings showed no statistical difference in univariate analysis or in multivariate analysis. Conclusion: No suggestion was found of a negative effect on school performance from in utero exposure of diagnostic X-ray pelvimetry. -- Highlights: •Pelvimetric examinations expose fetus to low levels of radiation. •No detectable effect on childrens final primary school grades from pelvimetric examinations. •Pelvimetric examinations is a safe procedure for the fetus regarding shool performance

  15. Asymmetric Exchange Rate Exposures: A Search for the Effect of Real Options

    DEFF Research Database (Denmark)

    Aabo, Tom

    2001-01-01

    Real options like the ability to reallocate production resources can lead to an asymmetric exchange rate exposure. Using a stock market approach in which the exchange rate exposure is derived from the information content in the stock prices this study examines the extra-market exchange rate...... exposures of a group of blue chip, industrial companies listed on the Copenhagen Stock Exchange. In these companies the existence of real options is an integrated part of the exchange rate exposure management process. The result of the stock market approach is mixed. Statistically significant asymmetric...... exchange rate exposures are identified successfully but the asymmetries can only to a limited extent be explained by the existence of real options. Financial options and pricing to market are competing explanations. Omitted variable bias further blurs the picture. These problems and the concept of path...

  16. The effect of exposure rate of the growth of soybean seedlings grown from gamma irradiated seeds

    International Nuclear Information System (INIS)

    Mohd Yusof, A.; Grunewald, R.

    1981-01-01

    The effect of the gamma ( 137 Cs) total exposure rate of 25 kR delivered at three different exposure rates (887 R/min, 159 R/min and 48 R/min) on soybean seeds was studied by measuring seedling height, cotyledon area, fresh weight, dry weight, Co 2 fixation and RuDP carboxylase activity. The dry weight, CO 2 fixation and irradiated imbibed groups did not show any correlation with exposure rate. Exposure rate effect was shown for the first stage out, no further correlation was observed in the subsequent stages, probably due to the recovery and repair mechanisms that take place as the seedling increases with age. The absence of an exposure rate effect on irradiated imbibed group may be explained in terms of non-detectable damage at a very high dose, since these seedlings exhibited effects that are similar to the effects of seeds exposed to an acute radiation dose. (author)

  17. Exposure reduction in general dental practice using digital x-ray imaging system for intraoral radiography with additional x-ray beam filter

    International Nuclear Information System (INIS)

    Shibuya, Hitoshi; Mori, Toshimichi; Hayakawa, Yoshihiko; Kuroyanagi, Kinya; Ota, Yoshiko

    1997-01-01

    To measure exposure reduction in general dental practice using digital x-ray imaging systems for intraoral radiography with additional x-ray beam filter. Two digital x-ray imaging systems, Pana Digital (Pana-Heraus Dental) and CDR (Schick Technologies), were applied for intraoral radiography in general dental practice. Due to the high sensitivity to x-rays, additional x-ray beam filters for output reduction were used for examination. An Orex W II (Osada Electric Industry) x-ray generator was operated at 60 kVp, 7 mA. X-ray output (air-kerma; Gy) necessary for obtaining clinically acceptable images was measured at 0 to 20 cm in 5 cm steps from the cone tip using an ionizing chamber type 660 (Nuclear Associates) and compared with those for Ektaspeed Plus film (Eastman Kodak). The Pana Digital system was used with the optional filter supplied by Pana-Heraus Dental which reduced the output to 38%. The exposure necessary to obtain clinically acceptable images was only 40% of that for the film. The CDR system was used with the Dental X-ray Beam Filter Kit (Eastman Kodak) which reduced the x-ray output to 30%. The exposure necessary to obtain clinically acceptable images was only 20% of that for the film. The two digital x-ray imaging systems, Pana Digital and CDR, provided large dose savings (60-80%) compared with Ektaspeed Plus film when applied for intraoral radiography in general dental practice. (author)

  18. Digital approach to high rate gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Korolczuk, Stefan; Mianowski, Slawomir; Rzadkiewicz, Jacek; Sibczynski, Pawel; Swiderski, Lukasz; Szewinski, Jaroslaw; Zychor, Izabella [Narodowe Centrum Badan Jadrowych (NCBJ), 05-400 Otwock, (Poland)

    2015-07-01

    Basic concepts and preliminary results of creating high rate digital spectrometry system using efficient ADCs and latest FPGA are presented as well as a comparison with commercially available devices. The possibility to use such systems, coupled to scintillators, in plasma experiments is discussed. (authors)

  19. Noble gases, nitrogen and cosmic ray exposure age of the Sulagiri chondrite

    Directory of Open Access Journals (Sweden)

    Ramakant R. Mahajan

    2017-01-01

    Full Text Available The Sulagiri meteorite fell in India on 12 September 2008, LL6 chondrite class is the largest among all the Indian meteorites. Isotopic compositions of noble gases (He, Ne, Ar, Kr and Xe and nitrogen in the Sulagiri meteorite and cosmic ray exposure history are discussed. Low cosmogenic (22Ne/21Nec ratio is consistent with irradiation in a large body. Cosmogenic noble gases indicate that Sulagiri has a 4π cosmic-ray exposure (CRE age of 27.9 ± 3.4 Ma and is a member of the peak of CRE age distribution of LL chondrites. Radiogenic 4He and 40Ar concentrations in Sulagiri yields the radiogenic ages as 2.29 and 4.56 Ga, indicating the loss of He from the meteorite. Xenon and krypton are mixture of Q and spallogenic components.

  20. Noble gases, nitrogen and cosmic ray exposure age of the Sulagiri chondrite

    Institute of Scientific and Technical Information of China (English)

    Ramakant R. Mahajan

    2017-01-01

    The Sulagiri meteorite fell in India on 12 September 2008, LL6 chondrite class is the largest among all the Indian meteorites. Isotopic compositions of noble gases (He, Ne, Ar, Kr and Xe) and nitrogen in the Sulagiri meteorite and cosmic ray exposure history are discussed. Low cosmogenic (22Ne/21Ne)c ratio is consistent with irradiation in a large body. Cosmogenic noble gases indicate that Sulagiri has a 4πcosmic-ray exposure (CRE) age of 27.9 ± 3.4 Ma and is a member of the peak of CRE age distribution of LL chondrites. Radiogenic 4He and 40Ar concentrations in Sulagiri yields the radiogenic ages as 2.29 and 4.56 Ga, indicating the loss of He from the meteorite. Xenon and krypton are mixture of Q and spallo-genic components.

  1. An Industrial Radipgraphy Exposure Device Based on Measurement of Transmitted Gamma-Ray Intensity

    International Nuclear Information System (INIS)

    Polee, C.; Chankow, N.; Srisatit, S.; Thong-Aram, D.

    2014-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking knowledge of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a D3372 Hamamatsu small GM tube. Application software is developed for Android mobile phone to remotely control the device and to display the counting data via Bluetooth. Prior to placing film, the device is placed behind the specimen to be radiographed to determine the exposure time from the transmitted intensity which is independent on source activity, source-to-film distance, specimen thickness and kind of material. The developed technique and device make radiographic process economic, convenient and more reliable.

  2. Mass accretion rate fluctuations in black hole X-ray binaries

    NARCIS (Netherlands)

    Rapisarda, S.

    2017-01-01

    This thesis is about the first systematic and quantitative application of propagating mass accretion rate fluctuations models to black hole X-ray binaries. Black hole X-ray binaries are systems consisting of a solar mass star orbiting around a stellar mass black hole. Eventually, the black hole

  3. Occupational exposure of medical staff due to diagnostic X-ray examinations in veterinary medicine

    Energy Technology Data Exchange (ETDEWEB)

    Mergel, E.; Feige, S. [Gesellschaft fuer Anlagen- und Reaktorsicherheit mbH (GRS) (Germany); Haeusler, U. [Bundesamt fuer Strahlenschutz (BfS), Salzgitter (Germany)

    2007-07-01

    The implementation of the Council directive 96/29 EURATOM and the corresponding national Radiation Protection Ordinance and the X-ray Protection Ordinance coming subsequently into effect led to a changed situation regarding the occupational radiation protection in the medical sector. To reduce the occupational exposure of veterinarians and assisting staff in veterinary radiography is particularly challenging as, in opposite to human radiological examination, the presence of staff is indispensable to restrain the patient. Beyond that the relevant literature reports about too high and/or about unnecessary radiation exposures. To gain a comprehensive knowledge upon the possible exposure of involved staff, the variety of typical examination methods in veterinary clinics and at practitioners had been investigated during the daily routine. Dose measurements were performed for different employees during the examinations taking into account several places of exposure (lens, thyroid, chest, hand, gonad, and feet). Veterinary X-ray diagnostic examinations for pets as well as in equine radiography had been accounted for this study. In total, 101 examination methods, 4.484 accompanied examinations and 53.892 single dose readings resulted in a reliable statistical base to set up a 'Job-Exposure-Matrix' allowing the dose assessment for a variable number and kind of examinations. The 'Job-Exposure-Matrix' is believed to be a useful tool for optimization of occupational radiation exposure of veterinarians by appraising the height of a possible dose, forcing a review of the status quo and triggering the improvement of personal protection by establishing adequate measures. (orig.)

  4. Stony meteoroid space erosion and drag: Effect on cosmic ray exposure ages

    Science.gov (United States)

    Rubincam, David Parry

    2017-09-01

    Collisions with dust particles in retrograde orbits cause space erosion on stony meteoroids in addition to the particle drag which causes drift toward resonances. The spacing between resonances determines the maximum drift time and sets upper limits on the neon-21 cosmic ray exposure (CRE) ages for meteoroids less than ∼1 m in radius, while space erosion controls the limit for radii greater than ∼1 m; the limits accord well with the measured CRE ages of stony meteorites.

  5. Cytological evidence of chromosomal rearrangement in the second meiotic division after exposure to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Szemere, G. (Orvostudomanyi Egyetem, Szeged (Hungary). Orvosbiologiai Intezet)

    1982-01-01

    Metaphase II cells with unequal dyad-arms and obvious X/autosomal rearrangements were found after an exposure to X-rays (2 Gy) of male mice at different stages of meiosis (pachytene, diplotene and diakinesis) with a frequency of 0.2, 1.26 and 0.6%, respectively, giving a direct cytological evidence of structural chromosomal rearrangements in metaphase II cells, partly with autosomal and partly with X/autosomal partners.

  6. Cytological evidence of chromosomal rearrangement in the second meiotic division after exposure to X-rays

    International Nuclear Information System (INIS)

    Szemere, G.

    1982-01-01

    Metaphase II cells with unequal dyad-arms and obvious X/autosomal rearrangements were found after an exposure to X-rays (2 Gy) of male mice at different stages of meiosis (pachytene, diplotene and diakinesis) with a frequency of 0.2, 1.26 and 0.6%, respectively, giving a direct cytological evidence of structural chromosomal rearrangements in metaphase II cells, partly with autosomal and partly with X/autosomal partners. (author)

  7. Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

    Science.gov (United States)

    Benyo, Theresa L.; Steinetz, Bruce M.; Hendricks, Robert C.; Martin, Richard E.; Forsley, Lawrence P.; Daniels, Christopher C.; Chait, Arnon; Pines, Vladimir; Pines, Marianna; Penney, Nicholas; hide

    2017-01-01

    Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 µA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4s confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

  8. Cosmic ray exposure ages of features and events at the Apollo landing sites

    International Nuclear Information System (INIS)

    Arvidson, R.; Crozaz, G.; Drozd, R.J.; Hohenberg, C.M.; Morgan, C.J.

    1975-01-01

    Cosmic ray exposure ages of lunar samples have been used to date surface features related to impact cratering and downslope movement of material. Only when multiple samples related to a feature have the same rare gas exposure age, or when a single sample has the same 81 Kr-Kr and track exposure age can a feature be considered reliably dated. Because any single lunar sample is likely to have had a complex history, assignment of ages to features based upon only one determination by any method should be avoided. Based on the above criteria, there are only five well-dated lunar features: Cone Crater (Apollo 14) 26 m.y., North Ray Crater (Apollo 16) 50 m.y., South Ray Crater (Apollo 16) 2 m.y., the emplacement of the Station 6 boulders (Apollo 17) 22 m.y., and the emplacement of the Station 7 boulder (Apollo 17) 28 m.y. Other features are tentatively dated or have limits set on their ages: Bench Crater (Apollo 12) =50 m.y. (Auth.)

  9. Digital image acquisition in the X-ray diagnostics. Its influence on the patients' exposure

    International Nuclear Information System (INIS)

    Hoberg, Bernd; Voigt, Stefan

    2012-01-01

    Radiation exposure in the classical X-ray diagnostics was continuously reduced during the past years. The annual report 2009 of the Bundesamt fuer Strahlenschutz (BfS) shows that 46% of the radiological examinations in Germany concern the skeleton, the lungs and the digestive and urogenital tract. The respective radiation dose is only 20% of the total dose of the public from X-ray diagnostic measures. Considering computerized tomography, angiography and interventional radiology, that amount to about 10% of the radiological examinations, their dose percentage reaches about 80%. Therefore, the emphasis of modern radiation protection has to be targeted to digital techniques in the future X-ray diagnostics. The authors describe digital detectors, direct and indirect digitalized image receivers, flat-panel detectors and dynamic detectors.

  10. Joint analysis of French and Czech uranium miners: lung cancer risk at low radon exposure rates and modifying effects of time since exposure and age at exposure

    International Nuclear Information System (INIS)

    Ladislav Tomasek; Agnes Rogel; Margot Tirmarche; Dominique Laurier

    2006-01-01

    The present analysis was conducted in the frame of European project 'Quantification of lung cancer risk after low radon exposure and low exposure rate: synthesis from epidemiologic and experimental data'. The overall goal of the project related to uranium miners was the evaluation of lung cancer dose-response relationship and of dose rate effects among European uranium miners exposed to low doses and low dose rates of radon decay products. In addition, modifying factors like attained age, age at exposure and time since exposure were investigated. The joint analysis of French and Czech uranium miners was conducted mainly in order to increase the statistical power and to allow a more detailed description of the variation of dose-response relationship in time. (N.C.)

  11. Joint analysis of French and Czech uranium miners: lung cancer risk at low radon exposure rates and modifying effects of time since exposure and age at exposure

    Energy Technology Data Exchange (ETDEWEB)

    Ladislav Tomasek [National Radiation Protection Institute, Prague (Czech Republic); Agnes Rogel; Margot Tirmarche; Dominique Laurier [Institut de Radioprotection et de Surete Nucleaire, Fontenay-aux-Roses (France)

    2006-07-01

    The present analysis was conducted in the frame of European project 'Quantification of lung cancer risk after low radon exposure and low exposure rate: synthesis from epidemiologic and experimental data'. The overall goal of the project related to uranium miners was the evaluation of lung cancer dose-response relationship and of dose rate effects among European uranium miners exposed to low doses and low dose rates of radon decay products. In addition, modifying factors like attained age, age at exposure and time since exposure were investigated. The joint analysis of French and Czech uranium miners was conducted mainly in order to increase the statistical power and to allow a more detailed description of the variation of dose-response relationship in time. (N.C.)

  12. Update of diagnostic medical and dental x-ray exposures in Romania

    Energy Technology Data Exchange (ETDEWEB)

    Sorop, Ioana; Mossang, Daniela; Dadulescu, Elena [Radiation Hygiene Laboratory of Public Health Authority Dolj, 2, Constantin Lecca Street, Craiova (Romania); Iacob, Mihai Radu [University ' Alexandru Ioan Cuza' , 11, Carol I Street, 700506, Iasi (Romania); Iacob, Olga [Institute of Public Health, 14, Victor Babes Street, 700465 Iasi (Romania)], E-mail: danamossang@sanpubdj.ro

    2008-12-15

    This national study, the third in the last 15 years, updates the magnitude of medical radiation exposure from conventional x-ray examinations, in order to optimise the radiological protection to the population in a cost-effective manner. Effective doses from diagnostic radiology were estimated for adult and paediatric patients undergoing the 20 most important types of x-ray examination. Data were collected from 179 x-ray departments, selected by their annual workload, throughout the country. Estimates were made using two dosimetric quantities: entrance surface dose, derived from the absorbed dose in air measured by simulation of radiographic examinations, and dose-area product, measured during fluoroscopic examinations performed on adult and paediatric patients. Conversion coefficients to effective dose of the UK National Radiological Protection Board (NRPB) have been used in all calculations. The effective dose per patient from all medical x-ray examinations was 0.74 mSv and the resulting annual collective effective dose was 6930 man Sv, with annual effective dose per caput of 0.33 mSv. The current size of population exposure from diagnostic radiology is lower than the previous one by 40%, but could be about 30% higher by taking into account the estimated contribution from computed tomography (CT) procedures.

  13. Radiation exposure to chest X-rays in the neonatal nursery

    International Nuclear Information System (INIS)

    Takeuchi, Toshio; Itabashi, Kazuo; Kawaguchi, Shigeru; Suzuka, Takahisa; Okuyama, Kazuo

    1989-01-01

    To measure how much very low birth-weight infants are exposed to chest X-rays during nursery, skin doses were calculated using phantoms under the same condition as that used in chest X-rays. Skin doses obtained were multiplied by the number of X-rays performed in 86 very low birth-weight infants (mean birth weight+-SD, 1163.0+-232.8 g; mean gestational age+-SD, 29.3+-3.0 week). Exposure doses per film ranged from 4.9 to 14.4 mR, with a mean dose of 6.1+-2.0 mR. Exposure doses per neonate ranged from 6.3 to 794.3 mR, with a mean dose of 170.4+-151.5 mR. The number of films per neonate ranged from one to 107, with a mean of 28.0+-24.9. Eighty-seven percent of X-rays were performed when the body weight was 1,500 g or less. Fourteen patients received 300 mR or more that may be the potential dose of radiation effects. (Namekawa, K)

  14. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    OpenAIRE

    Soichiro Tsujino; Takashi Tomizaki

    2016-01-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinn...

  15. Myeloid leukaemia frequency after protracted exposure to ionizing radiation: experimental confirmation of the flat dose-response found in ankylosing spondylitis after a single treatment course with x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Mole, R H; Major, I R [Medical Research Council, Harwell (UK). Radiobiological Research Unit

    1983-01-01

    The dose-response for leukaemia induction by exposure to ionizing radiation protracted over several weeks was largely independent of dose not only in X-rayed patients with ankylosing spondylitis but also in experimentally ..gamma..-rayed CBA/H mice. In the experiment the induced leukaemia frequency of acute myeloid leukaemia was independent of a several thousand-fold variation in physical dose rate. Any difference in leukaemia induction between brief and protracted exposures must therefore depend on specifically biological consequences of protracted exposures. Experimental analysis is required to provide the guides for inference about risks of low level exposure from observations on relatively heavily irradiated populations.

  16. Optimization of exposure factors for X-ray radiography non-destructive testing of pearl oyster

    Science.gov (United States)

    Susilo; Yulianti, I.; Addawiyah, A.; Setiawan, R.

    2018-03-01

    One of the processes in pearl oyster cultivation is detecting the pearl nucleus to gain information whether the pearl nucleus is still attached in the shell or vomited. The common tool used to detect pearl nucleus is an X-ray machine. However, an X-ray machine has a drawback that is the energy used is higher than that used by digital radiography. The high energy make the resulted image is difficult to be analysed. One of the advantages of digital radiography is the energy used can be adjusted so that the resulted image can be analysed easily. To obtain a high quality of pearl image using digital radiography, the exposure factors should be optimized. In this work, optimization was done by varying the voltage, current, and exposure time. Then, the radiography images were analysed using Contrast to Noise Ratio (CNR). From the analysis, it can be determined that the optimum exposure factors are 60 kV of voltage, 16 mA of current, and 0.125 s of exposure time which result in CNR of 5.71.

  17. Clastogenic effects in human lymphocytes exposed to low and high dose rate X-ray irradiation and vitamin C

    International Nuclear Information System (INIS)

    Konopacka, M; Rogolinski, J.

    2011-01-01

    In the present work we investigated the ability of vitamin C to modulate clastogenic effects induced in cultured human lymphocytes by X-irradiation delivered at either high (1 Gy/min) or low dose rate (0.24 Gy/min). Biological effects of the irradiation were estimated by cytokinesis-block micronucleus assay including the analysis of the frequency of micronuclei (MN) and apoptotic cells as well as calculation of nuclear division index (NDI). The numbers of micronucleated binucleate lymphocytes (MN-CBL) were 24.85 ± 2.67% and 32.56 ± 3.17% in cultures exposed to X-rays (2 Gy) delivered at low and high dose rates, respectively. Addition of vitamin C (1-20 μg/ml) to the medium of cultures irradiated with the low dose rate reduced the frequency of micronucleated lymphocytes with multiple MN in a concentration-dependent manner. Lymphocytes exposed to the high dose rate radiation showed a U-shape response: low concentration of vitamin C significantly reduced the number of MN, whereas high concentration influenced the radiation-induced total number of micronucleated cells insignificantly, although it increased the number of cells with multiple MN. Addition of vitamin C significantly reduced the fraction of apoptotic cells, irrespective of the X-ray dose rate. These results indicate that radiation dose rate is an important exposure factor, not only in terms of biological cell response to irradiation, but also with respect to the modulating effects of antioxidants. (authors)

  18. Measurement of angular distribution of cosmic-ray muon fluence rate

    International Nuclear Information System (INIS)

    Lin, Jeng-Wei; Chen, Yen-Fu; Sheu, Rong-Jiun; Jiang, Shiang-Huei

    2010-01-01

    In this work a Berkeley Lab cosmic ray detector was used to measure the angular distribution of the cosmic-ray muon fluence rate. Angular response functions of the detector at each measurement orientation were calculated by using the FLUKA Monte Carlo code, where no energy attenuation was taken into account. Coincidence counting rates were measured at ten orientations with equiangular intervals. The muon angular fluence rate spectrum was unfolded from the measured counting rates associated with the angular response functions using both the MAXED code and the parameter adjusting method.

  19. Europium- and lithium-doped yttrium oxide nanocrystals that provide a linear emissive response with X-ray radiation exposure

    Science.gov (United States)

    Stanton, Ian N.; Belley, Matthew D.; Nguyen, Giao; Rodrigues, Anna; Li, Yifan; Kirsch, David G.; Yoshizumi, Terry T.; Therien, Michael J.

    2014-04-01

    Eu- and Li-doped yttrium oxide nanocrystals [Y2-xO3 Eux, Liy], in which Eu and Li dopant ion concentrations were systematically varied, were developed and characterized (TEM, XRD, Raman spectroscopic, UV-excited lifetime, and ICP-AES data) in order to define the most emissive compositions under specific X-ray excitation conditions. These optimized [Y2-xO3 Eux, Liy] compositions display scintillation responses that: (i) correlate linearly with incident radiation exposure at X-ray energies spanning from 40-220 kVp, and (ii) manifest no evidence of scintillation intensity saturation at the highest evaluated radiation exposures [up to 4 Roentgen per second]. For the most emissive nanoscale scintillator composition, [Y1.9O3; Eu0.1, Li0.16], excitation energies of 40, 120, and 220 kVp were chosen to probe the dependence of the integrated emission intensity upon X-ray exposure-rate in energy regimes having different mass-attenuation coefficients and where either the photoelectric or the Compton effect governs the scintillation mechanism. These experiments demonstrate for the first time for that for comparable radiation exposures, when the scintillation mechanism is governed by the photoelectric effect and a comparably larger mass-attenuation coefficient (120 kVp excitation), greater integrated emission intensities are recorded relative to excitation energies where the Compton effect regulates scintillation (220 kVp) in nanoscale [Y2-xO3 Eux] crystals. Nanoscale [Y1.9O3; Eu0.1, Li0.16] (70 +/- 20 nm) was further exploited as a detector material in a prototype fiber-optic radiation sensor. The scintillation intensity from the [Y1.9O3; Eu0.1, Li0.16]-modified, 400 μm sized optical fiber tip, recorded using a CCD-photodetector and integrated over the 605-617 nm wavelength domain, was correlated with radiation exposure using a Precision XRAD 225Cx small-animal image guided radiation therapy (IGRT) system. For both 80 and 225 kVp energies, this radiotransparent device recorded

  20. Advanced Computational Approaches for Characterizing Stochastic Cellular Responses to Low Dose, Low Dose Rate Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Bobby, R., Ph.D.

    2003-06-27

    applications of NEOTRANS2, indicate that nonlinear threshold-type, dose-response relationships for excess stochastic effects (problematic nonlethal mutations, neoplastic transformation) should be expected after exposure to low linear energy transfer (LET) gamma rays or gamma rays in combination with high-LET alpha radiation. Similar thresholds are expected for low-dose-rate low-LET beta irradiation. We attribute the thresholds to low-dose, low-LET radiation induced protection against spontaneous mutations and neoplastic transformations. The protection is presumed mainly to involve selective elimination of problematic cells via apoptosis. Low-dose, low-LET radiation is presumed to trigger wide-area cell signaling, which in turn leads to problematic bystander cells (e.g., mutants, neoplastically transformed cells) selectively undergoing apoptosis. Thus, this protective bystander effect leads to selective elimination of problematic cells (a tissue cleansing process in vivo). However, this protective bystander effects is a different process from low-dose stimulation of the immune system. Low-dose, low-LET radiation stimulation of the immune system may explain why thresholds for inducing excess cancer appear much larger (possibly more than 100-fold larger) than thresholds for inducing excess mutations and neoplastic transformations, when the dose rate is low. For ionizing radiation, the current risk assessment paradigm is such that the relative risk (RR) is always ¡Ý 1, no matter how small the dose. Our research results indicate that for low-dose or low-dose-rate, low-LET irradiation, RR < 1 may be more the rule than the exception. Directly tied to the current RR paradigm are the billion-dollar cleanup costs for radionuclide-contaminated DOE sites. Our research results suggest that continued use of the current RR paradigm for which RR ¡Ý 1 could cause more harm than benefit to society (e.g., by spreading unwarranted fear about phantom excess risks associated with low-dose low

  1. Exposure reduces negative bias in self-rated performance in public speaking fearful participants.

    Science.gov (United States)

    Cheng, Joyce; Niles, Andrea N; Craske, Michelle G

    2017-03-01

    Individuals with public speaking anxiety (PSA) under-rate their performance compared to objective observers. The present study examined whether exposure reduces the discrepancy between self and observer performance ratings and improved observer-rated performance in individuals with PSA. PSA participants gave a speech in front of a small audience and rated their performance using a questionnaire before and after completing repeated exposures to public speaking. Non-anxious control participants gave a speech and completed the questionnaire one time only. Objective observers watched videos of the speeches and rated performance using the same questionnaire. PSA participants underrated their performance to a greater degree than did controls prior to exposure, but also performed significantly more poorly than did controls when rated objectively. Bias significantly decreased and objective-rated performance significantly increased following completion of exposure in PSA participants, and on one performance measure, anxious participants no longer showed a greater discrepancy between self and observer performance ratings compared to controls. The study employed non-clinical student sample, but the results should be replicated in clinical anxiety samples. These findings indicate that exposure alone significantly reduces negative performance bias among PSA individuals, but additional exposure or additional interventions may be necessary to fully correct bias and performance deficits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Distribution and characteristics of gamma and cosmic ray dose rate in living environment

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Moriuchi, Shigeru

    1991-01-01

    A series of environmental radiation surveys was carried out from the viewpoint of characterizing the natural radiation dose rate distribution in the living environment, including natural and artificial ones. Through the analysis of the data obtained at numbers of places, several aspects of the radiation field in living environments were clarified. That is the gamma ray dose rate varies due to the following three dominant causes: 1) the radionuclide concentration of surrounding materials acting as gamma ray sources, 2) the spatial distribution of surrounding materials, and 3) the geometrical and shielding conditions between the natural gamma ray sources and the measured point; whereas, the cosmic ray dose rate varies due to the thickness of upper shielding materials. It was also suggested that the gamma ray dose rate generally shows an upward tendency, and the cosmic ray dose rate a downward one in artificial environment. This kind of knowledge is expected to serve as fundamental information for accurate and realistic evaluation of the collective dose in the living environment. (author)

  3. ULY JUP GRB SOLAR X-RAY/COSMIC GAMMA-RAY RAW COUNT RATE

    Data.gov (United States)

    National Aeronautics and Space Administration — The archived data consist of count rates from the sum of two hemispherical detectors covering 4 pi steradians and operating continuously. The detectors are 3 mm...

  4. Cosmic ray exposure dating with in situ produced cosmogenic 3He: results from young Hawaiian lava flows

    Science.gov (United States)

    Kurz, M.D.; Colodner, D.; Trull, T.W.; Moore, R.B.; O'Brien, K.

    1990-01-01

    In an effort to determine the in situ production rate of spallation-produced cosmogenic 3He, and evaluate its use as a surface exposure chronometer, we have measured cosmogenic helium contents in a suite of Hawaiian radiocarbon-dated lava flows. The lava flows, ranging in age from 600 to 13,000 years, were collected from Hualalai and Mauna Loa volcanoes on the island of Hawaii. Because cosmic ray surface-exposure dating requires the complete absence of erosion or soil cover, these lava flows were selected specifically for this purpose. The 3He production rate, measured within olivine phenocrysts, was found to vary significantly, ranging from 47 to 150 atoms g-1 yr-1 (normalized to sea level). Although there is considerable scatter in the data, the samples younger than 10,000 years are well-preserved and exposed, and the production rate variations are therefore not related to erosion or soil cover. Data averaged over the past 2000 years indicate a sea-level 3He production rate of 125 ?? 30 atoms g-1 yr-1, which agrees well with previous estimates. The longer record suggests a minimum in sea level normalized 3He production rate between 2000 and 7000 years (55 ?? 15 atoms g-1 yr-1), as compared to samples younger than 2000 years (125 ?? 30 atoms g-1 yr-1), and those between 7000 and 10,000 years (127 ?? 19 atoms g-1 yr-1). The minimum in production rate is similar in age to that which would be produced by variations in geomagnetic field strength, as indicated by archeomagnetic data. However, the production rate variations (a factor of 2.3 ?? 0.8) are poorly determined due to the large uncertainties in the youngest samples and questions of surface preservation for the older samples. Calculations using the atmospheric production model of O'Brien (1979) [35], and the method of Lal and Peters (1967) [11], predict smaller production rate variations for similar variation in dipole moment (a factor of 1.15-1.65). Because the production rate variations, archeomagnetic data

  5. The acceleration rate of cosmic rays at cosmic ray modified shocks

    Science.gov (United States)

    Saito, Tatsuhiko; Hoshino, Masahiro; Amano, Takanobu

    It is a still controversial matter whether the production efficiency of cosmic rays (CRs) is relatively efficient or inefficient (e.g. Helder et al. 2009; Hughes et al. 2000; Fukui 2013). In upstream region of SNR shocks (the interstellar medium), the energy density of CRs is comparable to a substantial fraction of that of the thermal plasma (e.g. Ferriere 2001). In such a situation, CRs can possibly exert a back-reaction to the shocks and modify the global shock structure. These shocks are called cosmic ray modified shocks (CRMSs). In CRMSs, as a result of the nonlinear feedback, there are almost always up to three steady-state solutions for given upstream parameters, which are characterized by CR production efficiencies (efficient, intermediate and inefficient branch). We evaluate qualitatively the efficiency of the CR production in SNR shocks by considering the stability of CRMS, under the effects of i) magnetic fields and ii) injection, which play significant roles in efficiency of acceleration. By adopting two-fluid model (Drury & Voelk, 1981), we investigate the stability of CRMSs by means of time-dependent numerical simulations. As a result, we show explicitly the bi-stable feature of these multiple solutions, i.e., the efficient and inefficient branches are stable and the intermediate branch is unstable, and the intermediate branch transit to the inefficient one. This feature is independent of the effects of i) shock angles and ii) injection. Furthermore, we investigate the evolution from a hydrodynamic shock to CRMS in a self-consistent manner. From the results, we suggest qualitatively that the CR production efficiency at SNR shocks may be the least efficient.

  6. Probabilistic estimation of residential air exchange rates for population-based human exposure modeling

    Science.gov (United States)

    Residential air exchange rates (AERs) are a key determinant in the infiltration of ambient air pollution indoors. Population-based human exposure models using probabilistic approaches to estimate personal exposure to air pollutants have relied on input distributions from AER meas...

  7. Rates and Psychological Effects of Exposure to Family Violence among Sri Lankan University Students

    Science.gov (United States)

    Haj-Yahia, Muhammad M.; de Zoysa, Piyanjli

    2008-01-01

    Objectives: The study had two objectives: to examine the rates of exposure to family violence among students in a non-Western society, with Sri Lanka as a case study and to examine the psychological effects of their exposure. Method: Four hundred seventy six medical students in Sri Lanka were surveyed. A self-administered questionnaire was…

  8. Optimized control of X-ray exposure and image noise using a particular multislice CT scanner

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki; Koyama, Yoshihiro; Nagasawa, Hirofumi

    2008-01-01

    Patient dose reduction in computed tomography (CT) always results in a trade off between radiation exposure and image quality. There are few reports that estimate the relationship between image quality and X-ray exposure in CT examinations as one optimal index. The purpose of this study was to determine the optimal parameter settings enabling a low radiation exposure without compromising image quality using a particular 4-row multislice CT (MSCT) scanner (Aquilion VZ 4-slice CT scanner, Toshiba Medical Systems Corporation, Otawara, Tochigi, Japan). Normalized dose divided by image noise for helical pitches (nDNR: normalized dose to noise ratio) were calculated in consideration of beam collimation and tube current-time product. Optimal tube current-time product was calculated using the nDNR for the helical pitches based on user-defined standards of quality of the CT image. As a result, the nDNR proved to be well-supported to decrease the patient exposure in various exposure conditions of MSCT scans; however, the dose and image noise did not show a linear relation to the helical pitch. In conclusion, nDNR can be applied to patient dose reduction while keeping an acceptable image quality using a particular 4-row MSCT scanner. (author)

  9. A Firm-Specific Analysis of the Exchange-Rate Exposure of Dutch Firms

    NARCIS (Netherlands)

    A. de Jong (Abe); J. Ligterink; V. Macrae

    2002-01-01

    textabstractWe examine the relationship between exchange-rate changes and stock returns for a sample of Dutch firms over 1994-1998. We find that over 50% of the firms are significantly exposed to exchange-rate risk. Furthermore, all firms with significant exchange-rate exposure benefit from a

  10. A re-evaluation of the 0-10 ka 10Be production rate for exposure dating obtained from the Koefels (Austria) landslide

    International Nuclear Information System (INIS)

    Kubik, Peter W.; Ivy-Ochs, Susan

    2004-01-01

    The sea level, high latitude 10 Be production rate for exposure dating obtained from the giant 9.8 ka landslide of Koefels (Austria) has been calculated based on a re-assessment of the contribution of the muonic cosmic ray component. The 0-10 ka production rate value is 5.44 ± 0.19 10 Be atoms/y g quartz

  11. On the Dependence of the X-Ray Burst Rate on Accretion and Spin Rate

    Science.gov (United States)

    Cavecchi, Yuri; Watts, Anna L.; Galloway, Duncan K.

    2017-12-01

    Nuclear burning and its dependence on the mass accretion rate are fundamental ingredients for describing the complicated observational phenomenology of neutron stars (NSs) in binary systems. Motivated by high-quality burst rate data emerging from large statistical studies, we report general calculations relating the bursting rate to the mass accretion rate and NS rotation frequency. In this first work, we ignore general relativistic effects and accretion topology, although we discuss where their inclusion should play a role. The relations we derive are suitable for different burning regimes and provide a direct link between parameters predicted by theory and what is to be expected in observations. We illustrate this for analytical relations of different unstable burning regimes that operate on the surface of an accreting NS. We also use the observed behavior of the burst rate to suggest new constraints on burning parameters. We are able to provide an explanation for the long-standing problem of the observed decrease of the burst rate with increasing mass accretion that follows naturally from these calculations: when the accretion rate crosses a certain threshold, ignition moves away from its initially preferred site, and this can cause a net reduction of the burst rate due to the effects of local conditions that set local differences in both the burst rate and stabilization criteria. We show under which conditions this can happen even if locally the burst rate keeps increasing with accretion.

  12. Device for measuring the exposure time in dental X-ray - Cronox

    International Nuclear Information System (INIS)

    Menezes, Claudio J.M.; Santos, Luiz A.P. dos

    2009-01-01

    The Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) developed a test device for monitoring the X-ray beam in dental equipment to its application in quality control programs. This device, called Odontologic Dosimetric Card (CDO of Cartao Dosimetrico Odontologico in Portuguese) uses thermoluminescent dosimeters (TLD) for the measurement of some parameters of the X-ray beam as the entrance surface dose, the peak tension and half value layer (HVL). Radiographic films record the size of the radiation field. However, the TLD does not allow the assessment of exposure time, a parameter that complements the requirements of the Diretrizes de Protecao Radiologica em Radiodiagnostico Medico e Odontologico of Department of Health in Brazil for such equipment. Thus was developed a system based on sensitivity to ionizing radiation of phototransistors for measurement of exposure time when a patient is put in a clinical dental radiography. The system, called CRONOX was sized to be inserted within the CDO. The results showed that the measuring error had developed for less than 3% when compared to reference values obtained with the Tektronix digital oscilloscope, TDS2022 model. The readings obtained with the CRONOX were also compared with the nominal values selected in the X-ray equipment and with the values measured with the instrument of trade PTW Diavolt Universal. The results showed that the measuring device developed showed a maximum deviation of 5.92% on the nominal value selected, while for the instrument of PTW was 17.86%. (author)

  13. Comparison of hurricane exposure methods and associations with county fetal death rates, adjusting for environmental quality

    Science.gov (United States)

    Adverse effects of hurricanes are increasing as coastal populations grow and events become more severe. Hurricane exposure during pregnancy can influence fetal death rates through mechanisms related to healthcare, infrastructure disruption, nutrition, and injury. Estimation of hu...

  14. Effects of embryonic and fetal exposure to x-ray, microwaves, and ultrasound

    International Nuclear Information System (INIS)

    Brent, R.L.

    1986-01-01

    Many professionals are unfamiliar with radiation biology or the quantitative nature of the risks. Frequently, microwave, ultrasound, and ionizing radiation risks are confused. Although it is impossible to prove no risk for any environmental hazard, it appears that exposure to microwave radiation below the maximal permissible levels present no measurable risk to the embryo. Ultrasound exposure from diagnostic ultrasonographic imaging equipment also is quite innocuous. It is true that continued surveillance and research into potential risks of these low-level exposures should continue, but at present ultrasound not only improves obstetric care but also reduces the necessity of diagnostic x-ray procedures. In the field of ionizing radiation, we have as good a comprehension of the biologic effects and the quantitative maximum risks as of any other environmental hazard. Although the animal and human data support the conclusion that no increases in the incidence of gross congenital malformations, intrauterine growth retardation, or abortion will occur with exposures less than 5 rad, that does not mean that there are definitely no risks to the embryo exposed to lower doses of radiation. Whether there exists a linear or exponential dose-response relationship or a threshold exposure for genetic, carcinogenic, cell-depleting, and life-shortening effects has not been determined. In establishing maximum permissible levels for the embryo at low exposures, refer to Tables 4, 5, 6, 8, and 9. It is obvious that the risks of 1-rad or 5-rad acute exposure are far below the spontaneous risks of the developing embryo because 15 per cent of human embryos abort, 2.7 to 3.0 per cent of human embryos have major malformations, 4 per cent have intrauterine growth retardation, and 8 to 10 per cent have early- or late-onset genetic disease. 98 references

  15. Measurements of natural radiation exposure rates in various living environments. 4

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1993-01-01

    The absorbed dose rates in air due to the terrestrial γ-ray and the cosmic rays were measured on five subway lines in Nagoya City and in the underground shopping malls in Sakae and The Nagoya Station areas as the basic data to estimate the population dose. The mean values of the γ-ray dose rates were 36.3 ± 7.3 nGy/h and 56.1 ± 6.4 nGy/h in the subway lines and in the underground shopping malls, respectively. It is inferred that the variation in the γ-ray dose rate is mainly due to the difference in the concentration of natural radionuclides contained in the building materials of the subway tunnels and of the ceilings of the underground malls. The cosmic ray dose rates lay in the range of ca. 1/2-1/3 of the ground level value due to the shielding effect of the materials covering over the subway tunnels or the underground shopping malls. The mean value of the total dose rate for the gamma and the cosmic rays in the subway lines was about 50% and that in the underground shopping malls was about 20% lower than the value (87.3 nGy/h) on the ground in Nagoya City. (author)

  16. Exposure to Low-Dose X-Ray Radiation Alters Bone Progenitor Cells and Bone Microarchitecture.

    Science.gov (United States)

    Lima, Florence; Swift, Joshua M; Greene, Elisabeth S; Allen, Matthew R; Cunningham, David A; Braby, Leslie A; Bloomfield, Susan A

    2017-10-01

    Exposure to high-dose ionizing radiation during medical treatment exerts well-documented deleterious effects on bone health, reducing bone density and contributing to bone growth retardation in young patients and spontaneous fracture in postmenopausal women. However, the majority of human radiation exposures occur in a much lower dose range than that used in the radiation oncology clinic. Furthermore, very few studies have examined the effects of low-dose ionizing radiation on bone integrity and results have been inconsistent. In this study, mice were irradiated with a total-body dose of 0.17, 0.5 or 1 Gy to quantify the early (day 3 postirradiation) and delayed (day 21 postirradiation) effects of radiation on bone microarchitecture and bone marrow stromal cells (BMSCs). Female BALBc mice (4 months old) were divided into four groups: irradiated (0.17, 0.5 and 1 Gy) and sham-irradiated controls (0 Gy). Micro-computed tomography analysis of distal femur trabecular bone from animals at day 21 after exposure to 1 Gy of X-ray radiation revealed a 21% smaller bone volume (BV/TV), 22% decrease in trabecular numbers (Tb.N) and 9% greater trabecular separation (Tb.Sp) compared to sham-irradiated controls (P X-rays, whereas osteoclastogenesis was enhanced. A better understanding of the effects of radiation on osteoprogenitor cell populations could lead to more effective therapeutic interventions that protect bone integrity for individuals exposed to low-dose ionizing radiation.

  17. Effect of medical x-ray exposure on subsequent reproductive outcomes in scoliosis patients

    International Nuclear Information System (INIS)

    Visscher, W.A.

    1987-01-01

    A retrospective cohort study was done which was designed to assess the effects of medical x-ray exposure on cancer incidence among scoliosis patients. Although the primary purpose of the study was to assess cancer incidence, a secondary goal was to investigate whether diagnostic x-ray exposure is related to adverse reproductive events in the female subjects. A series of case-control analyses were done which were designed to assess these effects. Radiation exposure was measured both by total films received and by an estimate of the number of films received and by an estimate of the number of films which involved ovarian irradiation. Radiation appeared to increase a woman's risk of any adverse event in the overall analysis and her risk of a premature or low birth weight infant in the separate analyses. Radiation did not appear to be related to spontaneous abortion, complications of pregnancy or delivery or birth defects, although the results of the pregnancy complications analysis was suggestive

  18. A survey of medical exposure during X-ray diagnosis in Aomori

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    The purpose of this project was to survey medical exposure doses in Aomori Prefecture and compare them with guidance levels for X-ray diagnosis. A questionnaire survey on X-ray diagnosis was conducted at the main medical institutions in the prefecture. The questionnaire asked about technical conditions, and replies were obtained from 72.2% of the 79 institutions. The medical exposure doses (entrance surface doses) were calculated from the results of the questionnaires by the modified numerical dose determination (NDD) method. The distribution of the entrance surface doses at each site was calculated as the 1st quartile, median, 3rd quartile, average, standard deviation, maximum value and minimum value, by the quartile method. The distribution of exposed doses at each site showed a similar pattern with that of the national distribution. Some institutions used higher doses than the Japanese proposed guidance levels and International Atomic Energy Agency (IAEA) guidance levels. Re-assessment of radiographic conditions and photosensitive materials is needed to reduce exposure doses. (K.H.)

  19. Injury of the blood-testies barrier after low-dose-rate chronic radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Young Hoon; Bae Min Ji; Lee, Chang Geun; Yang, Kwang Mo; Jur, Kyu; Kim, Jong Sun [Dongnam Institute of Radiological and Medical Science, Busan (Korea, Republic of)

    2014-04-15

    The systemic effect of radiation increases in proportionally with the dose and dose rate. Little is known concerning the relationships between harmful effects and accumulated dose, which is derived from continuous low-dose rate radiation exposure. Recent our studies show that low-dose-rate chronic radiation exposure (3.49 mGy/h) causes adverse effects in the testis at a dose of 2 Gy (6 mGy/h). However, the mechanism of the low-dose-rate 2 Gy irradiation induced testicular injury remains unclear. The present results indicate that low-dose rate chronic radiation might affect the BTB permeability, possibly by decreasing levels of ZO-1, Occludin-1, and NPC-2. Furthermore, our results suggest that there is a risk of male infertility through BTB impairment even with low-dose-rate radiation if exposure is continuous.

  20. Conversion of Airborne Gamma ray Spectra to Ground Level Air Kerma Rates

    DEFF Research Database (Denmark)

    Bargholz, Kim; Korsbech, Uffe C C

    1997-01-01

    A new method for relating airborne gamma-ray spectra to dose rates and kerma rates at ground level is presented. Dependent on flying altitude 50 m to 125 m the method gives correct results for gamma energies above 250 keV respective 350 keV. At lower energies the method underestimate the dose...... or kerma rates; by having a large fraction of the ground level gamma-rays at energies below 350 keV special care should be taken at an interpretation of the results....

  1. Measurement of exposure dose rate by TLD in 60Co garden

    International Nuclear Information System (INIS)

    Fan Chengfang; Li Pinfang; Wu Maoliang; Zhao Quan

    1987-01-01

    The use of TLD method to measure exposure dose rate in 60 Co garden is described. As compared with chemical dosimetry, the relative deviation of measurement would not exceed 10%. The good repeatability has been proved by comparing the measurements of different times and distances with correction of decay law and 1/1 2 law. Besides, the distribution of exposure dose rate was influenced by scattering of the living plants

  2. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  3. Radiation exposure of holding personnel involved in veterinary X-ray diagnosis

    International Nuclear Information System (INIS)

    Rothe, W.

    1977-01-01

    An account is given of radiation protection in the context of X-ray examination of small and big animals on the premises of seven reviewed veterinary centres. Also reported are the dosimetric results obtained from holding personnel involved in X-ray diagnosis of 319 big and 4,047 small animals. Infringement of valid regulations was quite often observed, in that animals are held in position in an inadequate way and by unauthorised persons. The measured results, however, have shown that the radiation exposure of vocationally exposed persons can be kept far below the maximum permissible equivalent doses, provided that all applicable rules of radiation protection are observed by those on duty. (author)

  4. Radiation exposure of the Yazd Population from medical conventional X-ray examinations

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Zare, M. H.; Dashti, M. H.

    2007-01-01

    Radiation dose knowledge through X-ray examinations and their distribution in Iran provides useful guidance on patient dose reduction. The results of the entrance skin dose (ESD s ) of five common radiographs in all radiology centers in Yazd province were reported in our previous study (2003). In the present study we have evaluated the collective effective dose of conventional X-ray examinations, as well as the annual per caput of Yazd population.Materials and Methods: The annual frequencies of 18 different types of conventional radiology examinations during April 2005 to March 2006 were recorded from all 35 radiology centers in Yazd province. The exposure conditions consisted of kVp, mAs, and Focus surface distance (FSD) of the examinations for the mode of exposure in each X-ray unit. 620 ESD were measured by diode dosimeter in 35 hospitals and clinics. The real exposure kVp for each radiology unit was measured by a Molt-0-Meter. The conversion coefficient (effective dose - ESD ratio) for each radiology examination was determined by using SR262 tables. Finally, the patients' effective dose was calculated by multiplying the conversion factor to the ESD. Results: The patients' annual collective effective dose due to the conventional radiology examinations was 31.159 man-Sv (0.03 mSv per inhabitant). The frequency of examinations was 311813 i.e. 0.36 examinations per head of the population for one year. Conclusion: According to our findings, the effective per caput dose seems to be optimally relative to HCL-II countries, which may be due to low mean effective dose that could obscure high examination frequency. The number of radiology conventional examinations and frequency of radiologist per1000 population of Yazd was more and lower than HCL-II countries respectively. Thus the justification of radiography requests in this province must be revised

  5. ANATOMICAL DISPOSITION OF CARPAL BONES OF GOLDEN RETRIEVER DOG BY X-RAY EXPOSURE

    Directory of Open Access Journals (Sweden)

    R. Mandal

    2012-07-01

    Full Text Available The present study was conducted to know the general disposition of bones in carpal region of experimental dogs by X-ray study with an objective that the findings will facilitate to have an in-depth knowledge about the proper positioning of the carpal bones for surgical management of fractures and different types of bone deformities in dogs. In the present study, the anatomical disposition and arrangement pattern of carpal bones playing a pivotal role in providing the structural conformity in the limbs of Golden Retriever dog has been thoroughly confirmed by Xray exposure.

  6. DNA Topoisomerase-I Inhibition due to Exposure to X-Rays

    International Nuclear Information System (INIS)

    Daudee, R.; Gonen, R.; German, U.; Orion, I.; Priel, E.

    2014-01-01

    In events such as radiological terrorism, accidents involving radioactive materials and occupational exposures, there is a great need to identify exposures to relatively low radiation levels. In many situations, the evaluation of radiation doses is not possible using physical dosimeters as they are not worn, and it is desirable to achieve this based on sensitive biomarkers (1, 2, 3). DNA Topoisomerase-I (Topo-I) is an essential nuclear enzyme that is responsible for the topological state of the DNA. The enzyme is involved in a variety of DNA transactions, including replication, transcription, recombination and DNA repair (4,5). The aim of the present work was to investigate the influence of X-ray radiation on the catalytic activity of this enzyme, and to evaluate its applicability as a biological dosimeter

  7. Calculation of dose-rate conversion factors for external exposure to photons and electrons

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1978-01-01

    Methods are presented for the calculation of dose-rate conversion factors for external exposure to photon and electron radiation from radioactive decay. A dose-rate conversion factor is defined as the dose-equivalent rate per unit radionuclide concentration. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each radiation type and exposure mode, dose-rate conversion factors are derived for tissue-equivalent material at the body surface of an exposed individual. In addition, photon dose-rate conversion factors are estimated for 22 body organs. The calculations are based on the assumption that the exposure medium is infinite in extent and that the radionuclide concentration is uniform. The dose-rate conversion factors for immersion in contaminated air and water then follow from the requirement that all of the energy emitted in the radioactive decay is absorbed in the infinite medium. Dose-rate conversion factors for ground-surface exposure are calculated at a reference location above a smooth, infinite plane using the point-kernel integration method and known specific absorbed fractions for photons and electrons in air

  8. Modifications of γ-ray sensitivity of bacterial membranes by pre-exposure to light

    International Nuclear Information System (INIS)

    Misiti-Dorello, P.; Cancelliere, G.; De Martino, G.; Quintilini, M.

    1976-01-01

    The exposure of E. coli B/r cells to ultraviolet or to visible light prior to irradiation with γ-rays modifies the sensitivity of the cell membrane to radiation damage responsible for the intracellular K + content. Exposure of bacterial cells to sublethal doses of UV radiation increases their sensitivity to γ-induced membrane damage, while exposure to visible light has the opposite effect. In combined exposures, the visible light, either given before or after the UV always produces a strong photoprotective effect. In either case, the photosensitizing effect of UV is completely suppressed. The photoprotection decays with time if cell suspensions are left in the dark before γ-irradiation. At O 0 C, the half-life of the photoprotective effect is 25 min at pH 7 and 100 min at pH 7.5. The decay is due to the presence of oxygen. The light band responsible for the induction of photoprotection has been estimated to lie in the wavelenght region between 540 and 580 nm. (orig./MG) [de

  9. Determination of exposure rates from natural background radiation in Khartoum using LiF:Mg,Cu,P (GR-200) and CaSo4: Mn TLD chips

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khangi, F.A.; Shaddad, I.A.; Suliman, I.A.; El Amin, O.I.

    2002-01-01

    The exposure rates from natural background radiation - including terrestrial gamma radiation and the ionizing component of cosmic rays - were measured for the first time in the city of khartoum using two types of TLD materials: LiF:Mg,Cu,P (GR-200) and CaSo 4 :Mn TLD chips. Measurements were performed at two sites simultaneously, one site was selected on land in the vicinity of the Sudan Atomic Energy Commission, for the purposes of the measurement of the total exposure rate outdoors, while the other site was located on a buoy anchored in the Blue Nile, and was selected to measure the exposure rate due to the ionizing component of cosmic rays. The investigations were conducted for periods of between 5 and 28 days. Calibration was performed on a selected number of dosimeters to determine the exposure rates at each site. The exposure rates from the ionizing component of cosmic rays in Khartoum were found to be respectively 33 nGy.h -1 and 30 nGy.h -1 , in the measurements performed within the scope of this work using GR-200 and CaSo 4 :Mn dosimeters, while the total values for exposure on land were found to be 45 nGy.h -1 and 42 nGy.h -1 respectively. These values compare reasonably well with other national averages reported in the UNSCEAR publication. The comparison of the results for the two dosimetric materials demonstrates both the sensitivity and suitability of GR-200 for the purposes of environmental monitoring (orig.)

  10. Application of airborne gamma spectrometric survey data to estimating terrestrial gamma-ray dose rates: An example in California

    International Nuclear Information System (INIS)

    Wollenberg, H.A.; Revzan, K.L.; Smith, A.R.

    1992-01-01

    The authors examine the applicability of radioelement data from the National Aerial Radiometric Reconnaissance (NARR) to estimate terrestrial gamma-ray absorbed dose rates, by comparing dose rates calculated from aeroradiometric surveys of U, Th, and K concentrations in 1 x 2 degree quadrangles with dose rates calculated from a radiogeologic data base and the distribution of lithologies in California. Gamma-ray dose rates increase generally from north to south following lithological trends. Low values of 25--30 nG/h occur in the northernmost quadrangles where low-radioactivity basaltic and ultramafic rocks predominate. Dose rates then increase southward due to the preponderance of clastic sediments and basic volcanics of the Franciscan Formation and Sierran metamorphics in north central and central California, and to increasing exposure southward of the Sierra Nevada batholith, Tertiary marine sedimentary rocks, intermediate to acidic volcanics, and granitic rocks of the Coast Ranges. High values, to 100 nGy/h occur in southeastern California, due primarily to the presence of high-radioactivity Precambrian and pre Cenozoic metamorphic rocks. Lithologic-based estimates of mean dose rates in the quadrangles generally match those from aeroradiometric data, with statewide means of 63 and 60 nGy/h, respectively. These are intermediate between a population-weighted global average of 51 nGy/h and a weighted continental average of 70 nGy/h, based on the global distribution of rock types. The concurrence of lithologically- and aeroradiometrically- determined dose rates in California, with its varied geology and topography encompassing settings representative of the continents, indicates that the NARR data are applicable to estimates of terrestrial absorbed dose rates from natural gamma emitters

  11. Quantification of lung cancer risk after low radon exposure and low exposure rate: synthesis from epidemiological and experimental data

    International Nuclear Information System (INIS)

    Timarche, M.

    2004-03-01

    Radon is a radioactive gas produced during the decay of uranium 238 that is present in soil. It was classified as a human lung carcinogen in 1988, based on evidence both from animal studies and from human studies of miners with high levels of radon exposure. Radon is present everywhere; therefore the quantification of the risk associated with exposure to it is a key public health issue. The project aimed to analyse the risk associated with radon inhalation at low doses and at low rates of exposure. It involved researchers from three different fields: epidemiology, animal experiments and mechanistic modelling and provided a unique opportunity to study the influence of dose rate, mainly in the range of low daily exposures over long periods, by analysing in parallel results from both animal and epidemiological studies. The project comprised 6 work packages (W.P.). Firstly, the partners involved in epidemiology and animal experiments worked on the validation and the analysis of the data. Secondly, the data from W.P.1 and W.P.4 were transferred to the partners involved in W.P.5 for the application of mechanistic models. In the final step a synthesis of the results was prepared. (N.C)

  12. Quantification of lung cancer risk after low radon exposure and low exposure rate: synthesis from epidemiological and experimental data

    Energy Technology Data Exchange (ETDEWEB)

    Timarche, M

    2004-03-15

    Radon is a radioactive gas produced during the decay of uranium 238 that is present in soil. It was classified as a human lung carcinogen in 1988, based on evidence both from animal studies and from human studies of miners with high levels of radon exposure. Radon is present everywhere; therefore the quantification of the risk associated with exposure to it is a key public health issue. The project aimed to analyse the risk associated with radon inhalation at low doses and at low rates of exposure. It involved researchers from three different fields: epidemiology, animal experiments and mechanistic modelling and provided a unique opportunity to study the influence of dose rate, mainly in the range of low daily exposures over long periods, by analysing in parallel results from both animal and epidemiological studies. The project comprised 6 work packages (W.P.). Firstly, the partners involved in epidemiology and animal experiments worked on the validation and the analysis of the data. Secondly, the data from W.P.1 and W.P.4 were transferred to the partners involved in W.P.5 for the application of mechanistic models. In the final step a synthesis of the results was prepared. (N.C)

  13. Determination of the strain hardening rate of metals and alloys by X ray diffraction

    International Nuclear Information System (INIS)

    Cadalbert, Robert

    1977-01-01

    This report for engineering graduation is based on the study of X ray diffraction line profile which varies with the plastic strain rate of the metal. After some generalities of strain hardening (consequence of a plastic deformation on the structure of a polycrystalline metal, means to study a strain hardened structure, use of X ray diffraction to analyse the strain hardened crystalline structure), the author reports the strain hardening rate measurement by using X ray diffraction. Several aspects are addressed: principles, experimental technique, apparatus, automation and programming of the measurement cycle, method sensitivity and precision. In the next part, the author reports applications: measurement of the strain hardening rate in different materials (tubes with hexagonal profile, cylindrical tubes in austenitic steel), and study of the evolution of strain hardening with temperature [fr

  14. ABCC-JNIH adult health study Hiroshima and Nagasaki 1961 exposure to medical x-ray. Preliminary survey

    Energy Technology Data Exchange (ETDEWEB)

    Ishimaru, Toranosuke; Russell, W J

    1962-05-16

    A survey was conducted for three months among subjects seen in the medical clinics of ABCC, Hiroshima and Nagasaki, to determine the extent of medical x-ray received in ABCC and other hospitals and clinics. Emphasis was chiefly methodological to prepare for later studies designed to evaluate the contribution of medical x-ray to total radiation dose received by survivors of the atomic bombings and controls. The frequency, the institution in which the subject received x-ray, as well as the types of exposure were the prime considerations in the survey. The data were analyzed for each city by sex, age, and exposure status. 2 references, 5 figures, 11 tables.

  15. PM2.5 metal exposures and nocturnal heart rate variability: a panel study of boilermaker construction workers

    Directory of Open Access Journals (Sweden)

    Herrick Robert F

    2008-07-01

    Full Text Available Abstract Background To better understand the mechanism(s of particulate matter (PM associated cardiovascular effects, research priorities include identifying the responsible PM characteristics. Evidence suggests that metals play a role in the cardiotoxicity of fine PM (PM2.5 and in exposure-related decreases in heart rate variability (HRV. We examined the association between daytime exposure to the metal content of PM2.5 and night HRV in a panel study of boilermaker construction workers exposed to metal-rich welding fumes. Methods Twenty-six male workers were monitored by ambulatory electrocardiogram (ECG on a workday while exposed to welding fume and a non-workday (baseline. From the ECG, rMSSD (square root of the mean squared differences of successive intervals was summarized over the night (0:00–7:00. Workday, gravimetric PM2.5 samples were analyzed by x-ray fluorescence to determine metal content. We used linear mixed effects models to assess the associations between night rMSSD and PM2.5 metal exposures both with and without adjustment for total PM2.5. Matched ECG measurements from the non-workday were used to control for individual cardiac risk factors and models were also adjusted for smoking status. To address collinearity between PM2.5 and metal content, we used a two-step approach that treated the residuals from linear regression models of each metal on PM2.5 as surrogates for the differential effects of metal exposures in models for night rMSSD. Results The median PM2.5 exposure was 650 μg/m3; median metal exposures for iron, manganese, aluminum, copper, zinc, chromium, lead, and nickel ranged from 226 μg/m3 to non-detectable. We found inverse linear associations in exposure-response models with increased metal exposures associated with decreased night rMSSD. A statistically significant association for manganese was observed, with a decline of 0.130 msec (95% CI: -0.162, -0.098 in night rMSSD for every 1 μg/m3 increase in

  16. Population kinetics studies in mouse jejunum exposed prenatally to gamma rays at different dose rates

    International Nuclear Information System (INIS)

    Godha, Meena; Nand Chahal, K.

    2001-01-01

    Pregnant Swiss albino mice of 18 days post conception were exposed to 0.80 Gy, 0.40 Gy and 0.20 Gy of gamma rays from a Cobalt-60 source at different dose rates (.0584 Gy/min and .00091 Gy/min). Post irradiation variations in the cell population of crypts and villus of jejunum were studied in the F 1 -generation at 1 day, 3 day and 1,2,4,6 and 12 weeks of post-partum age. In all the exposure groups at 1 day post-partum age, crypts show a decrease in total cells, mitotic figures and goblet cells on one hand and an increase in PNNC on the other hand in comparison to coeval controls. At this interval a decrease in the number of total cells as well as goblet cells/villus column was also noticeable. Dead cells which were prominently seen in crypts were totally absent in villi. The first signs of recovery can be observed on day 3 p.p. when total cell population, mitotic activity and goblet cells of crypt registered an increase while percentage of PNNC showed a fall. Percentage of total cell population and goblet cells/villus column also increased. The recovery continued up to 2 week of p.p. age. At p.p. age of 4 weeks a relapse of damage was observed when values for all the parameters of crypt and villi registered a fall except PNNC. This is followed by a second phase of recovery and by 6 and 12 weeks of post-partum age, normal value were obtained for all the parameters. (author)

  17. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers.

    Science.gov (United States)

    Burns, Katrina N; Sun, Kan; Fobil, Julius N; Neitzel, Richard L

    2016-01-19

    Electronic waste (e-waste) is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people's livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA) and community (70 dBA) noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen's Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman's ρ 0.46, p stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  18. Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians

    Science.gov (United States)

    Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.

    2018-06-01

    The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (Pgroups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.

  19. Effects of pre-natal X-ray exposure on learning behaviour of mice

    International Nuclear Information System (INIS)

    Frank, P.; Faber, U.; Budny, T.

    1983-01-01

    The authors investigated whether prenatal X-raying affects the learning behaviour of mice. For this purpose they irradiated mice of strain C57BL/6Ffm with 130 r at different points of the fetal phase. Unirradiated mice served as controls. The animals underwent two learning test series of 14 days each teaching them optical signs. The results of the test series show a distinctly inferior learning ability in the animals exposed to pre-natal irradiation as compared to unirradiated controls. The extent of the reduction of the learning ability depends on the stage of the pregnancy at the time of X-ray exposure. The greatest difference as compared to non-irradiated mice occurred in the animals irradiated at the earliest stage (13th/14th day of pregnancy). The results of the other test groups (15th/16th and 17th/18th day of pregnancy) exhibited less distinct, but still significant differences to the controls. Exposure at the latest period (17th/18th day) coincided with the smallest difference. (orig./MG) [de

  20. Cellular oncogene expression following exposure of mice to γ-rays

    International Nuclear Information System (INIS)

    Anderson, A.; Woloschak, G.E.

    1991-01-01

    We examined the effects of total body exposure of BCF1 mice to γ-rays (300 cGy) in modulating expression of cellular oncogenes in both gut and liver tissues. We selected specific cellular oncogenes (c-fos, c-myc, c-src, and c-H-ras), based on their normal expression in liver and gut tissues from untreated mice. As early as 5 min. following whole body exposure of BCF1 mice to γ-rays we detected induction of mRNA specific for c-src and c-H-ras in both liver and gut tissues. c-fos RNA was slightly decreased in accumulation in gut but was unaffected in liver tissue from irradiated mice relative to untreated controls. c-myc mRNA accumulation was unaffected in all tissues examined. These experiments document that modulation of cellular oncogene expression can occur as an early event in tissues following irradiation and suggest that this modulation may play a role in radiation-induced carcinogenesis

  1. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Energy Technology Data Exchange (ETDEWEB)

    Starkenburg, Daken J. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Johns, Paul M. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Detection Systems Group, Pacific Northwest National Laboratory, Richland, Washington 99354, USA; Baciak, James E. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Nino, Juan C. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Xue, Jiangeng [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA

    2017-12-14

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  2. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Science.gov (United States)

    Starkenburg, Daken J.; Johns, Paul M.; Baciak, James E.; Nino, Juan C.; Xue, Jiangeng

    2017-12-01

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.18 μGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  3. DEPENDENCE OF X-RAY BURST MODELS ON NUCLEAR REACTION RATES

    Energy Technology Data Exchange (ETDEWEB)

    Cyburt, R. H.; Keek, L.; Schatz, H. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Amthor, A. M. [Department of Physics and Astronomy, Bucknell University, Lewisburg, PA 17837 (United States); Heger, A.; Meisel, Z.; Smith, K. [Joint Institute for Nuclear Astrophysics (JINA), Michigan State University, East Lansing, MI 48824 (United States); Johnson, E. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States)

    2016-10-20

    X-ray bursts are thermonuclear flashes on the surface of accreting neutron stars, and reliable burst models are needed to interpret observations in terms of properties of the neutron star and the binary system. We investigate the dependence of X-ray burst models on uncertainties in (p, γ ), ( α , γ ), and ( α , p) nuclear reaction rates using fully self-consistent burst models that account for the feedbacks between changes in nuclear energy generation and changes in astrophysical conditions. A two-step approach first identified sensitive nuclear reaction rates in a single-zone model with ignition conditions chosen to match calculations with a state-of-the-art 1D multi-zone model based on the Kepler stellar evolution code. All relevant reaction rates on neutron-deficient isotopes up to mass 106 were individually varied by a factor of 100 up and down. Calculations of the 84 changes in reaction rate with the highest impact were then repeated in the 1D multi-zone model. We find a number of uncertain reaction rates that affect predictions of light curves and burst ashes significantly. The results provide insights into the nuclear processes that shape observables from X-ray bursts, and guidance for future nuclear physics work to reduce nuclear uncertainties in X-ray burst models.

  4. REVEALING TYPE Ia SUPERNOVA PHYSICS WITH COSMIC RATES AND NUCLEAR GAMMA RAYS

    International Nuclear Information System (INIS)

    Horiuchi, Shunsaku; Beacom, John F.

    2010-01-01

    Type Ia supernovae (SNe Ia) remain mysterious despite their central importance in cosmology and their rapidly increasing discovery rate. The progenitors of SNe Ia can be probed by the delay time between progenitor birth and explosion as SNe Ia. The explosions and progenitors of SNe Ia can be probed by MeV nuclear gamma rays emitted in the decays of radioactive nickel and cobalt into iron. We compare the cosmic star formation and SN Ia rates, finding that their different redshift evolution requires a large fraction of SNe Ia to have large delay times. A delay-time distribution of the form t -α with α = 1.0 ± 0.3 provides a good fit, implying that 50% of SNe Ia explode more than ∼1 Gyr after progenitor birth. The extrapolation of the cosmic SN Ia rate to z = 0 agrees with the rate we deduce from catalogs of local SNe Ia. We investigate prospects for gamma-ray telescopes to exploit the facts that escaping gamma rays directly reveal the power source of SNe Ia and uniquely provide tomography of the expanding ejecta. We find large improvements relative to earlier studies by Gehrels et al. in 1987 and Timmes and Woosley in 1997 due to larger and more certain SN Ia rates and advances in gamma-ray detectors. The proposed Advanced Compton Telescope, with a narrow-line sensitivity ∼60 times better than that of current satellites, would, on an annual basis, detect up to ∼100 SNe Ia (3σ) and provide revolutionary model discrimination for SNe Ia within 20 Mpc, with gamma-ray light curves measured with ∼10σ significance daily for ∼100 days. Even more modest improvements in detector sensitivity would open a new and invaluable astronomy with frequent SN Ia gamma-ray detections.

  5. Shorter exposures to harder X-rays trigger early apoptotic events in Xenopus laevis embryos.

    Directory of Open Access Journals (Sweden)

    JiaJia Dong

    Full Text Available BACKGROUND: A long-standing conventional view of radiation-induced apoptosis is that increased exposure results in augmented apoptosis in a biological system, with a threshold below which radiation doses do not cause any significant increase in cell death. The consequences of this belief impact the extent to which malignant diseases and non-malignant conditions are therapeutically treated and how radiation is used in combination with other therapies. Our research challenges the current dogma of dose-dependent induction of apoptosis and establishes a new parallel paradigm to the photoelectric effect in biological systems. METHODOLOGY/PRINCIPAL FINDINGS: We explored how the energy of individual X-ray photons and exposure time, both factors that determine the total dose, influence the occurrence of cell death in early Xenopus embryo. Three different experimental scenarios were analyzed and morphological and biochemical hallmarks of apoptosis were evaluated. Initially, we examined cell death events in embryos exposed to increasing incident energies when the exposure time was preset. Then, we evaluated the embryo's response when the exposure time was augmented while the energy value remained constant. Lastly, we studied the incidence of apoptosis in embryos exposed to an equal total dose of radiation that resulted from increasing the incoming energy while lowering the exposure time. CONCLUSIONS/SIGNIFICANCE: Overall, our data establish that the energy of the incident photon is a major contributor to the outcome of the biological system. In particular, for embryos exposed under identical conditions and delivered the same absorbed dose of radiation, the response is significantly increased when shorter bursts of more energetic photons are used. These results suggest that biological organisms display properties similar to the photoelectric effect in physical systems and provide new insights into how radiation-mediated apoptosis should be understood and

  6. A synchrotron-based X-ray exposure station for radiation biology experiments

    International Nuclear Information System (INIS)

    Thompson, A.C.; Blakely, E.A.; Bjornstad, K.A.; Chang, P.Y.; Rosen, C.J.; Schwarz, R.I.

    2007-01-01

    Synchrotron X-ray sources enable radiation biology experiments that are difficult with conventional sources. A synchrotron source can easily deliver a monochromatic, tunable energy, highly collimated X-ray beam of well-calibrated intensity. An exposure station at beamline 10.3.1 of the Advanced Light Source (ALS) has been developed which delivers a variable energy (5-20 keV) X-ray fan beam with very sharp edges (10-90% in less than 3 μm). A series of experiments have been done with a four-well slide where a stripe (100 μm widex18 mm long) of cells in each well has been irradiated and the dose varied from well to well. With this facility we have begun a series of experiments to study cells adjacent to irradiated cells and how they respond to the damage of their neighbors. Initial results have demonstrated the advantages of using synchrotron radiation for these experiments

  7. A synchrotron-based X-ray exposure station for radiation biology experiments

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, A.C. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States)], E-mail: acthompson@lbl.gov; Blakely, E.A.; Bjornstad, K.A. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States); Chang, P.Y. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States); SRI International, Menlo Park, CA (United States); Rosen, C.J.; Schwarz, R.I. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States)

    2007-11-11

    Synchrotron X-ray sources enable radiation biology experiments that are difficult with conventional sources. A synchrotron source can easily deliver a monochromatic, tunable energy, highly collimated X-ray beam of well-calibrated intensity. An exposure station at beamline 10.3.1 of the Advanced Light Source (ALS) has been developed which delivers a variable energy (5-20 keV) X-ray fan beam with very sharp edges (10-90% in less than 3 {mu}m). A series of experiments have been done with a four-well slide where a stripe (100 {mu}m widex18 mm long) of cells in each well has been irradiated and the dose varied from well to well. With this facility we have begun a series of experiments to study cells adjacent to irradiated cells and how they respond to the damage of their neighbors. Initial results have demonstrated the advantages of using synchrotron radiation for these experiments.

  8. Effect of daily noise exposure monitoring on annual rates of hearing loss in industrial workers.

    Science.gov (United States)

    Rabinowitz, Peter M; Galusha, Deron; Kirsche, Sharon R; Cullen, Mark R; Slade, Martin D; Dixon-Ernst, Christine

    2011-06-01

    Occupational noise-induced hearing loss (NIHL) is prevalent, yet evidence on the effectiveness of preventive interventions is lacking. The effectiveness of a new technology allowing workers to monitor daily at-ear noise exposure was analysed. Workers in the hearing conservation program of an aluminium smelter were recruited because of accelerated rates of hearing loss. The intervention consisted of daily monitoring of at-ear noise exposure and regular feedback on exposures from supervisors. The annual rate of change in high frequency hearing average at 2, 3 and 4 KHz before intervention (2000-2004) and 4 years after intervention (2006-2009) was determined. Annual rates of loss were compared between 78 intervention subjects and 234 controls in other company smelters matched for age, gender and high frequency hearing threshold level in 2005. Individuals monitoring daily noise exposure experienced on average no further worsening of high frequency hearing (average rate of hearing change at 2, 3 and 4 KHz = -0.5 dB/year). Matched controls also showed decelerating hearing loss, the difference in rates between the two groups being significant (p hearing loss showed a similar trend but the difference was not statistically significant (p = 0.06). Monitoring daily occupational noise exposure inside hearing protection with ongoing administrative feedback apparently reduces the risk of occupational NIHL in industrial workers. Longer follow-up of these workers will help determine the significance of the intervention effect. Intervention studies for the prevention of NIHL need to include appropriate control groups.

  9. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  10. Exchange Rate Exposure and Its Determinants: A Firm and Industry Analysis of the UK Companies

    OpenAIRE

    He, Jiao

    2010-01-01

    This study assesses whether the unexpected exchange rate movements volatilize the UK firms’ stock return based on the firm- and industry-level analysis, and examines whether the magnitude of the exchange rate exposure is determined by the firm-specific factors. Using a sample of 244 UK companies listed in the FTSE 350 during the test period between December 1999 and December 2009, the result documents that the exchange rate fluctuation does affect the firm value. Among the five introduced ex...

  11. Study on exposures in incidents situations involving X-ray generators of industrial use

    International Nuclear Information System (INIS)

    Rios, Paulo B.; Rios, Denise A. da S.

    2014-01-01

    Case studies of accidents involving radiation sources provides valuable information for the improvement of equipment and procedures to be adopted to prevent their recurrence. Therefore, they are recommended as part of the licensing process of radiative facilities. However, when the equipment has no radiological protection requirements or have no record of accidents, an effective method to appropriate this knowledge necessary to improvements of process and project is the investigation of reported incidents and the proposition limit situations where exposures unlikely and even low intensity can occur. This work reviews incidents in X-ray equipment and thickness meters. Emergency situations are also studied in this type of equipment and in an accelerator of electrons self-shielded for curing of paints and varnishes. The exposure estimates are calculated from data collected in workplaces on the distance and time for each proposed case. Although there is no severe consequences to occupational health, the results can be used to improve the quality of training for operators and maintenance technicians, for proposing of new alarm systems and emergency teams procedures and may serve as a warning in inadvertent and avoidable situations of unnecessary exposures

  12. Implementation of a primary standard for a x-ray exposure

    International Nuclear Information System (INIS)

    peixoto, J.G.P.

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-rays of 100 K V to 250 K V of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation, beam homogeneity, influence of beam size and influences of temperature, humidity and atmospheric pressure. Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  13. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers

    Directory of Open Access Journals (Sweden)

    Katrina N. Burns

    2016-01-01

    Full Text Available Electronic waste (e-waste is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people’s livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA and community (70 dBA noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen’s Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman’s ρ 0.46, p < 0.001. A mixed effects linear regression model indicated that a 1 dB increase in noise exposure was associated with a 0.17 increase in heart rate (p-value = 0.01 even after controlling for work activities, age, smoking, perceived stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  14. Generation of plasma X-ray sources via high repetition rate femtosecond laser pulses

    Science.gov (United States)

    Baguckis, Artūras; Plukis, Artūras; Reklaitis, Jonas; Remeikis, Vidmantas; Giniūnas, Linas; Vengris, Mikas

    2017-12-01

    In this study, we present the development and characterization of Cu plasma X-ray source driven by 20 W average power high repetition rate femtosecond laser in ambient atmosphere environment. The peak Cu- Kα photon flux of 2.3 × 109 photons/s into full solid angle is demonstrated (with a process conversion efficiency of 10-7), using pulses with peak intensity of 4.65 × 1014 W/cm2. Such Cu- Kα flux is significantly larger than others found in comparable experiments, performed in air environment. The effects of resonance plasma absorption process, when optimized, are shown to increase measured flux by the factor of 2-3. The relationship between X-ray photon flux and plasma-driving pulse repetition rate is quasi-linear, suggesting that fluxes could further be increased to 1010 photons/s using even higher average powers of driving radiation. These results suggest that to fully utilize the potential of high repetition rate laser sources, novel target material delivery systems (for example, jet-based ones) are required. On the other hand, this study demonstrates that high energy lasers currently used for plasma X-ray sources can be conveniently and efficiently replaced by high average power and repetition rate laser radiation, as a way to increase the brightness of the generated X-rays.

  15. Late effects of chronic low dose-rate γ-rays irradiation on mice

    International Nuclear Information System (INIS)

    Tanaka, Satoshi; Sasagawa, Sumiko; Ichinohe, Kazuaki; Matsumoto, Tsuneya; Otsu, Hiroshi; Sato, Fumiaki

    2002-01-01

    To evaluate late biological effects of chronic low dose-rate radiation, we are conducting two experiments. Experiment 1 - Late effects of chronic low dose-rate g-rays irradiation on SPF mice, using life-span and pathological changes as parameters. Continuous irradiation with g-rays for 400 days was performed using 137 Cs γ-rays at dose-rates of 20 mGy/day, 1 mGy/day and 0.05 mGy/day with accumulated doses equivalent to 8,000 mGy, 400 mGy and 20 mGy, respectively. All mice were kept until they died a natural death. As of 2002 March 31, 3,999 of the total 4,000 mice have died. Preliminary analyses of data show that 20 mGy/day suggested a shortened life span in both sexes. Partial results show that the most common lethal neoplasms in the pooled data of non-irradiated control and irradiated male mice, in order of frequency, were neoplasms of the lymphohematopoietic system, liver, and lung. In female mice, neoplasms of the lymphohematopoietic system, soft tissue, and endocrine system were common. Experiment 2 - Effects on the progeny of chronic low dose-rate g-ray irradiated SPF mice: pilot study, was started in 1999 and is currently in progress. (author)

  16. Estimation of production rates for in-situ cosmogenic isotopes and application to surface exposure dating: certitudes and uncertainties

    International Nuclear Information System (INIS)

    Graham, I.J.

    1996-01-01

    Cosmogenic nuclides, produced in-situ in rocks by the action of cosmic rays on target nuclei, are increasingly being employed by earth scientists in a wide variety of applications. For example, surface exposure dating is used to determine erosion rates, the age of debris flows, alluvial fans, volcanic eruptions, meteoritic impact craters, and glacial deposits, and the timing of recent movement along faults and tectonic uplift. The technique can thus play a vital role in the study of potential hazards from geological processes, by establishing recurrence intervals between them, and establish chronologies and periodicities for major paleoclimatic events. Before surface exposure dating methods using cosmogenic isotopes can be applied even more widely, production rates of the main nuclides of interest must be better known, and their temporal and spatial variabilities determined. This paper summarises the present state of knowledge on production rates of the currently most useful nuclides ( 10 Be, 26 Al, 36 Cl, 14 C, 3 He and 21 Ne), discusses the main areas of concern, and makes suggestions for future improvement. (author). 83 refs., 7 tabs., 11 figs

  17. Radiation exposure rate and liquid level measurement inside a high level liquid waste (HLLW) storage tank

    International Nuclear Information System (INIS)

    Sur, B.; Yue, S.; Thekkevarriam, A.

    2007-01-01

    An instrument based on an inexpensive, small silicon diode has been developed and used to measure, for the first time, the gamma radiation exposure rate profile inside a 6.4 mm diameter reentrant thermo-well tube, immersed in the highly radioactive liquid solution in an HLLW storage tank. The measurement agrees with previous calculations of exposure rate, and provides confirmation for safe and effective radiation work plans and material selection for investigations and remediation of the storage tank facility. The measured radiation exposure rate profile is also used to confirm that the position of tank internal structures have not changed because of aging and corrosion, and to obtain, within a few mm, the level of liquid inside the tank. (author)

  18. Exposure to power frequency magnetic fields suppresses X-ray-induced apoptosis transiently in Ku80-deficient xrs5 cells

    International Nuclear Information System (INIS)

    Tian, Furong; Nakahara, Takehisa; Yoshida, Masami; Honda, Naoko; Hirose, Hideki; Miyakoshi, Junji

    2002-01-01

    In an attempt to determine whether exposure to extremely low frequency (ELF) electromagnetic fields can affect cells, Ku80-deficient cells (xrs5) and Ku80-proficient cells (CHO-K1) were exposed to ELF electromagnetic fields. Cell survival, and the levels of the apoptosis-related genes p21, p53, phospho-p53 (Ser 15 ), caspase-3 and the anti-apoptosis gene bcl-2 were determined in xrs5 and CHO-K1 cells following exposure to ELF electromagnetic fields and X-rays. It was found that exposure of xrs5 and CHO-K1 cells to 60 Hz ELF electromagnetic fields had no effect on cell survival, cell cycle distribution and protein expression. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields for 5 h after irradiation significantly inhibited G 1 cell cycle arrest induced by X-rays (1 Gy) and resulted in elevated bcl-2 expression. A significant decrease in the induction of p53, phospho-p53, caspase-3 and p21 proteins was observed in xrs5 cells when irradiation by X-rays (8 Gy) was followed by exposure to 5 mT ELF magnetic fields. Exposure of xrs5 cells to the ELF electromagnetic fields for 10 h following irradiation significantly decreased X-ray-induced apoptosis from about 1.7% to 0.7%. However, this effect was not found in CHO-K1 cells within 24 h of irradiation by X-rays alone and by X-rays combined with ELF electromagnetic fields. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields following irradiation can affect cell cycle distribution and transiently suppress apoptosis by decreasing the levels of caspase-3, p21, p53 and phospho-p53 and by increasing bcl-2 expression

  19. Normal rejoining of DNA strand breaks in ataxia telangiectasia fibroblast lines after low x-ray exposure

    International Nuclear Information System (INIS)

    Hariharan, P.V.; Eleczko, S.; Smith, B.P.; Paterson, M.C.

    1981-01-01

    The alkaline elution method was used to measure the enzymatic repair of x-ray-induced DNA strand breaks in skin fibroblasts derived from human subjects afflicted with ataxia telangiectasia (AT). Monolayer cultures of normal control and AT cell lines were exposed acutely to moderately lethal (250-rad) and highly lethal (1250-rad) doses of 250-kV x rays under aerobic conditions. Upon receiving 250 rad, the control fibroblasts from a clinically normal donor rejoined all detectable single-strand breaks (plus alkali-labile bonds) within 30 to 60 min of incubation. When challenged with 1250 rad the kinetics of strand rejoining by the normal control cells were biphasic. For both exposures, no significant difference in either the rate or the extent of strand rejoining was detected between the normal cell line (GM38) and three mutant cell lines (AT2BE, AT3BI, AT4BI) belonging to the three known genetic complementation groups in AT. It would thus appear that the enhanced radiosensitivity of cultured AT cells does not stem from faulty rejoining of radiogenic DNA strand breaks

  20. Dose-rate effects of ethylene oxide exposure on developmental toxicity.

    Science.gov (United States)

    Weller, E; Long, N; Smith, A; Williams, P; Ravi, S; Gill, J; Henessey, R; Skornik, W; Brain, J; Kimmel, C; Kimmel, G; Holmes, L; Ryan, L

    1999-08-01

    In risk assessment, evaluating a health effect at a duration of exposure that is untested involves assuming that equivalent multiples of concentration (C) and duration (T) of exposure have the same effect. The limitations of this approach (attributed to F. Haber, Zur Geschichte des Gaskrieges [On the history of gas warfare], in Funf Vortrage aus den Jahren 1920-1923 [Five lectures from the years 1920-1923], 1924, Springer, Berlin, pp. 76-92), have been noted in several studies. The study presented in this paper was designed to specifically look at dose-rate (C x T) effects, and it forms an ideal case study to implement statistical models and to examine the statistical issues in risk assessment. Pregnant female C57BL/6J mice were exposed, on gestational day 7, to ethylene oxide (EtO) via inhalation for 1.5, 3, or 6 h at exposures that result in C x T multiples of 2100 or 2700 ppm-h. EtO was selected because of its short half-life, documented developmental toxicity, and relevance to exposures that occur in occupational settings. Concurrent experiments were run with animals exposed to air for similar periods. Statistical analysis using models developed to assess dose-rate effects revealed significant effects with respect to fetal death and resorptions, malformations, crown-to-rump length, and fetal weight. Animals exposed to short, high exposures of EtO on day 7 of gestation were found to have more adverse effects than animals exposed to the same C x T multiple but at longer, lower exposures. The implication for risk assessment is that applying Haber's Law could potentially lead to an underestimation of risk at a shorter duration of exposure and an overestimation of risk at a longer duration of exposure. Further research, toxicological and statistical, are required to understand the mechanism of the dose-rate effects, and how to incorporate the mechanistic information into the risk assessment decision process.

  1. Risk assessment of medical exposure in X-ray examinations of children

    Directory of Open Access Journals (Sweden)

    I. G. Shatsky

    2017-01-01

    Full Text Available The use of the effective dose (the concept of which was developed for radiation protection of workers and public and the nominal risk coefficients, averaged by sex and age, to assess the radiation risks of medical exposure has some significant limitations. Age and sex distribution of the staff and the entire population may be quite different from the sex and age distribution of patients undergoing medical exposure. Moreover, the structure of the age and sex of patients may be different for various medical examinations. There are simplified methods for evaluating individual risk for patients undergoing medical exposure. The methods are based on the effective dose evaluation and those take in to account age and gender. A more accurate assessment of lifetime risk of delayed stochastic effects for health of the patient is achieved by using the organ doses and the age and gender risk factors. The aim of this work was evaluation of the lifetime risk of long-term stochastic health effects for different gender and age groups of children undergoing various radiographic investigations by using organ doses and the age and gender risk factors, and subsequent classification in accordance with generally accepted international risk scale. Data from surveys of33 X-ray units in 29 specialized pediatric health care organizations in Russia were used in the work. Organ doses and patient’s effective doses were calculated on the basis of the defined for each x-ray machine typical modes for the 12 radiographic procedures (X-ray exam of the skull, chest, cervical spine, thoracic spine, lumbar spine–all in two projections – of the abdomen and pelvis – both in one projectionusing a computer program PCXMC., Radiation risks for selected studies were estimated using the obtained organ doses and the age and gender risk factors calculated for the Russian population. The radiation risks were classified according to the international scale of the risks. It was found

  2. INTERSTELLAR METASTABLE HELIUM ABSORPTION AS A PROBE OF THE COSMIC-RAY IONIZATION RATE

    International Nuclear Information System (INIS)

    Indriolo, Nick; McCall, Benjamin J.; Hobbs, L. M.; Hinkle, K. H.

    2009-01-01

    The ionization rate of interstellar material by cosmic rays has been a major source of controversy, with different estimates varying by three orders of magnitude. Observational constraints of this rate have all depended on analyzing the chemistry of various molecules that are produced following cosmic-ray ionization, and in many cases these analyses contain significant uncertainties. Even in the simplest case (H + 3 ), the derived ionization rate depends on an (uncertain) estimate of the absorption path length. In this paper, we examine the feasibility of inferring the cosmic-ray ionization rate using the 10830 A absorption line of metastable helium. Observations through the diffuse clouds toward HD 183143 are presented, but yield only an upper limit on the metastable helium column density. A thorough investigation of He + chemistry reveals that only a small fraction of He + will recombine into the triplet state and populate the metastable level. In addition, excitation to the triplet manifold of helium by secondary electrons must be accounted for as it is the dominant mechanism which produces He* in some environments. Incorporating these various formation and destruction pathways, we derive new equations for the steady state abundance of metastable helium. Using these equations in concert with our observations, we find ζ He -15 s -1 , an upper limit about 5 times larger than the ionization rate previously inferred for this sight line using H + 3 . While observations of interstellar He* are extremely difficult at present, and the background chemistry is not nearly as simple as previously thought, potential future observations of metastable helium would provide an independent check on the cosmic-ray ionization rate derived from H + 3 in diffuse molecular clouds, and, perhaps more importantly, allow the first direct measurements of the ionization rate in diffuse atomic clouds.

  3. E-Commerce and Exchange Rate Exposure Management: A Tilt towards Real Hedging

    DEFF Research Database (Denmark)

    Aabo, Tom

    2001-01-01

    The aim of this paper is to address the impact of E-commerce on the balance between real hedging and financial hedging in the context of exchange rate exposure management in non-financial companies. A cross-case study of industrial companies highlights the inadequacy in taking a partial and static...... financial approach when managing exchange rate exposures. The paper argues that the emergence of E-commerce - by reducing the cost of obtaining, analyzing and allocating information - affects the dynamics of the markets and the dynamics of the company in such a way that a general tilt towards real hedging...

  4. Influence of radon daughter exposure rate, unattachment fraction, and disequilibrium on occurrence of lung tumours

    International Nuclear Information System (INIS)

    Cross, F.T.; Palmer, R.F.; Dagle, G.E.; Busch, R.H.; Buschbom, R.L.

    1984-01-01

    Groups of male, specific-pathogen-free (SPF), Wistar rats were exposed to several concentrations of radon daughters and uranium ore dust to clarify the roles of exposure rate, unattached RaA daughters, and the degree of radon daughter disequilibrium, in the development of respiratory system disease. Modelled, human dosimetric data indicate that the dose to sensitive tissues of the respiratory tract increases with increasing radon daughter unattachment fraction and degree of disequilibrium. Data bearing on these developments as well as updated results of experiments designed to test the role of radon daughter exposure rate on lung tumour incidence are reported. (author)

  5. Exposure to hazardous substances in Cathode Ray Tube (CRT) recycling sites in France

    Energy Technology Data Exchange (ETDEWEB)

    Lecler, Marie-Thérèse, E-mail: marie-therese.lecler@inrs.fr; Zimmermann, François; Silvente, Eric; Clerc, Frédéric; Chollot, Alain; Grosjean, Jérôme

    2015-05-15

    Highlights: • Chemical risks were assessed in the nine cathode ray tube screens recycling facilities. • The main hazardous agents are dust containing lead, cadmium, barium and yttrium. • Exposure and pollutant levels are described for different operations and processes. • All the operations and processes are concerned by significant levels of pollutants. • We suggest recommendations to reduce chemical risk. - Abstract: The Waste Electrical and Electronic Equipment (WEEE) or e-waste recycling sector has grown considerably in the last fifteen years due to the ever shorter life cycles of consumables and an increasingly restrictive policy context. Cathode Ray Tubes (CRTs) from used television and computer screens represent one of the main sources of e-waste. CRTs contain toxic materials such as lead, cadmium, barium, and fluorescent powders which can be released if recycling of CRTs is not appropriate. Exposure to these harmful substances was assessed in nine workshops where CRT screens are treated. Particulate exposure levels were measured using a gravimetric method and metals were analysed by plasma emission spectrometry. The maximum levels of worker exposure were 8.8 mg/m{sup 3}, 1504.3 μg/m{sup 3}, 434.9 μg/m{sup 3}, 576.3 μg/m{sup 3} and 2894.3 μg/m{sup 3} respectively for inhalable dust, barium, cadmium, lead and yttrium. The maximum levels of airborne pollutants in static samples were 39.0 mg/m{sup 3}, 848.2 μg/m{sup 3}, 698.4 μg/m{sup 3}, 549.3 μg/m{sup 3} and 3437.9 μg/m{sup 3} for inhalable dust, barium, cadmium, lead and yttrium. The most harmful operations were identified, and preventive measures for reducing the chemical risk associated with screen recycling were proposed. Workplace measurements were used to define recommendations for reducing the chemical risks in CRT screens recycling facilities and for promoting the design and development of “clean and safe” processes in emerging recycling channels.

  6. Development of X-ray CCD camera system with high readout rate using ASIC

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Matsuura, Daisuke; Anabuki, Naohisa; Miyata, Emi; Tsunemi, Hiroshi; Doty, John P.; Ikeda, Hirokazu; Katayama, Haruyoshi

    2009-01-01

    We report on the development of an X-ray charge-coupled device (CCD) camera system with high readout rate using application-specific integrated circuit (ASIC) and Camera Link standard. The distinctive ΔΣ type analog-to-digital converter is introduced into the chip to achieve effective noise shaping and to obtain a high resolution with relatively simple circuits. The unit test proved moderately low equivalent input noise of 70μV with a high readout pixel rate of 625 kHz, while the entire chip consumes only 100 mW. The Camera Link standard was applied for the connectivity between the camera system and frame grabbers. In the initial test of the whole system, we adopted a P-channel CCD with a thick depletion layer developed for X-ray CCD camera onboard the next Japanese X-ray astronomical satellite. The characteristic X-rays from 109 Cd were successfully read out resulting in the energy resolution of 379(±7)eV (FWHM) at 22.1 keV, that is, ΔE/E=1.7% with a readout rate of 44 kHz.

  7. Calculation of neutron and gamma-ray flux-to-dose-rate conversion factors

    International Nuclear Information System (INIS)

    Kwon, S.G.; Lee, S.Y.; Yook, C.C.

    1981-01-01

    This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute (ANSI) N666. These data are used to calculate the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoenergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions. (author)

  8. Gamma-ray dose rate increase at rainfall events and their air-mass origins

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2007-01-01

    The environmental γ-ray dose rate and precipitation rates were measured at our institute, in Rokkasho, Aomori, Japan. We analyzed 425 rainfall events in which the precipitation rate was over 0.5 mm from April through November during the years 2003 to 2005. Backward trajectories for 5 d starting from 1000 m above Rokkasho at the time of the maximum dose rate in a rainfall event, were calculated by using the HYSPLIT model of the NOAA Air Resources Laboratory. The trajectories for 5 d were classified by visual inspection according to the passage areas; Pacific Ocean, Asian Continent and Japan Islands. The increase of cumulative environmental γ-ray dose during a rainfall event was plotted against the precipitation in the event, and their relationship was separately examined according to the air-mass passage area, i.e. origin of the air-mass. Our results showed that the origin of air-mass was an important factor affecting the increase of environmental γ-ray dose rate by rainfall. (author)

  9. Comparison of late effects of single x-ray exposure, chronic tritiated water ingestion, and chronic cesium-137 gamma exposure in mice

    International Nuclear Information System (INIS)

    Carsten, A.L.; Cronkite, E.P.

    1979-01-01

    There is concern over the possible late effects resulting from chronic exposure to tritiated water, a primary by-product of power reactors. We are comparing the genetic and somatic effects of tritiated water ingestion to acute x-ray or chronic cesium-137 gamma-ray exposures. Eight week old mice were maintaned on tritiated water in concentrations of 0.3, 1.0, and 3.0 μCi/ml. Identical animals received cesium-137 gamma exposures equivalent to that from the tritiated water. At 4 week intervals, animals were sacrificed and the hematopoietic stem cell content and cellularity of the bone marrow determined. For comparison of acute and chronic effects, one group of mice received a single whole-body x-ray exposure of 525 rads. The x-irradiated animals showed an immediate sharp decrease in marrow cellularity followed by gradual return to normal levels, with a lifelong reduction in number of marrow stem cells. Animals exposed to the two higher concentrations of tritiated water showed only slight reductions in marrow cellularity, with a lifelong reduction in hematopoietic stem cells in the bone marrow. Comparison of the external gamma exposures to chronic tritiated water ingestion indicates similar patterns. Maintenance of normal cellularity with a reduced number of stem cells in x-rayed animals was shown by tritiated thymidine cytocide to be due to the reduction in number of stem cells in the resting G/sub O/ stage. At this time it is not possible to determine whether there is a significant difference in relative biological effectiveness of tritiated water compared to cesium-137 gamma rays; however, indications are that they are similar

  10. Measurement of environmental radiation exposure rates from Vernita, Hanford Reach, and Richland area shores. Addendum 1

    International Nuclear Information System (INIS)

    Cooper, A.T.

    1995-02-01

    Environmental radiation exposure rate measurements are taken on and around the Hanford Site for Pacific Northwest Laboratory's Hanford Site Surface Environmental Surveillance Project. In 1992, environmental radiation exposure rate measurements were taken from shoreline and island areas ranging from Vernita, along the Hanford Reach, down to the Richland Pumphouse. Measurements were taken primarily at locations known or expected to have elevated exposure rates as determined by examination of aerial photographs depicting radiation exposure measurements. Results from the 1992 survey indicated radiation exposure rates taken from the Hanford Reach area were elevated in comparison to the measurements taken from the Vernita area with ranges of 8 to 28 μR/hr and 4 to 11 μR/hr, respectively. In January 1994, additional shoreline radiation exposure rate measurements were taken from the Vernita, Hanford Reach, and Richland areas to determine the relationship of radiation exposure rates along the Richland area shores when compared to Vernita and Hanford Reach area exposure rates (measurements along the Richland area were not collected during the 1992 survey). This report discusses the 1994 results and is an addendum to the report that discussed the 1992 survey. An analysis of variance indicated a significant location interaction at a p-value of 0.0014. To determine differences between paried locations a post-hoc comparison of location means was performed on log transformed data using the Scheffacute e's F-test. This test indicated a significant difference between Hanford Reach and Richland area means with a mean difference of 0.075 /μR/hr and a p-value of 0.0014. No significant difference was found between Hanford Reach and Vernita area means: The mean difference was 0.031 μR/hr and the p-value was 0.3138. No significant difference was found between Vernita and Richland area means with a mean difference of 0.044 μR/hr and a p-value of 0.1155

  11. Improved model for solar cosmic ray exposure in manned Earth orbital flights

    International Nuclear Information System (INIS)

    Wilson, J.W.; Nealy, J.E.; Atwell, W.; Cucinotta, F.A.; Shinn, J.L.; Townsend, L.W.

    1990-06-01

    A calculational model is derived for use in estimating Solar cosmic ray exposure to critical body organs in low-Earth orbit at the center of a large spherical shield of fixed thickness. The effects of the Earth's geomagnetic field and the astronauts' self-shielding are evaluated explicitly. The geomagnetic field model is an approximate tilted eccentric dipole with geomagnetic storms represented as a uniform-impressed field. The storm field is related to the planetary geomagnetic index K(sub p). The code is applied to the Shuttle geometry using the Shuttle mass distribution surrounding two locations on the flight deck. The Shuttle is treated as pure aluminum and the astronaut as soft tissue. Short-term, average fluence over a single orbit is calculated as a function of the location of the lines of nodes or long-term averages over all lines of nodes for a fixed inclination

  12. Medical management of severe local radiation injury after acute X-ray exposure

    International Nuclear Information System (INIS)

    Bushmanov, A.; Nadezhina, N.; Kretov, A.

    2008-01-01

    Medical management during acute period in a case of severe local radiation injury after acute X-ray exposure includes 3 stages. During the fist stage patient got conservative treatment according to the common pathogenetic mechanisms of LRI (dis aggregating therapy, stimulation of regeneration, dis intoxication therapy, antibiotic therapy, pain relief therapy, Local anti-burn therapy-specific non-adhesive bandage with antiseptic and anti-burn medicaments); estimation of severity, deepness and area of injury by clinical picture and dates of instrumental methods of examining; defining necessity and volume of surgical treatment; preparing arrangements for surgical treatment. This stage ends with forming of demarcation line of a very hard severity of a Local Radiation Injure. The second stage includes necrectomy of the area of a very hard severity with microsurgical plastic by re vascularized flap and auto dermoplastic. The third stage - adaptation of re vascularized flap and total epithelization of injured area. (author)

  13. Gamma-ray energy absorption and exposure buildup factor studies in some human tissues with endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Kurudirek, Murat, E-mail: mkurudirek@gmail.co [Faculty of Science, Department of Physics, Ataturk University, 25240 Erzurum (Turkey); Dogan, Bekir [Faculty of Science, Department of Physics, Ataturk University, 25240 Erzurum (Turkey); Ingec, Metin [Faculty of Medicine, Department of Obstetrics and Gynecology, Ataturk University, 25240 Erzurum (Turkey); Ekinci, Neslihan; Ozdemir, Yueksel [Faculty of Science, Department of Physics, Ataturk University, 25240 Erzurum (Turkey)

    2011-02-15

    Human tissues with endometriosis have been analyzed in terms of energy absorption (EABF) and exposure (EBF) buildup factors using the five-parameter geometric progression (G-P) fitting formula in the energy region 0.015-15 MeV up to a penetration depth of 40 mfp (mean free path). Chemical compositions of the tissue samples were determined using a wavelength dispersive X-ray fluorescence spectrometer (WDXRFS). Possible conclusions were drawn due to significant variations in EABF and EBF for the selected tissues when photon energy, penetration depth and chemical composition changed. Buildup factors so obtained may be of use when the method of choice for treatment of endometriosis is radiotherapy.

  14. Life span and tumorigenesis in mice exposed to continuous low dose-rate gamma-rays

    International Nuclear Information System (INIS)

    Tanaka, Satoshi; Braga-Tanaka III, Ignacia; Takabatake, Takashi; Ichinohe, Kazuaki; Tanaka, Kimio; Matsumoto, Tsuneya; Sato, Fumiaki

    2004-01-01

    Two experiments were conducted to evaluate late biological effects of chronic low dose-rate radiation. 1: Late effects of chronic low dose-rate gamma-ray irradiation on SPF mice, using life span and pathological changes as parameters. Continuous irradiation for approximately 400 days was performed using 137 Cs gamma-rays at dose-rates of 20 mGy/day, 1 mGy/day and 0.05 mGy/day with accumulated doses equivalent to 8000 mGy, 400 mGy and 20 mGy, respectively. All mice were kept until their natural death. Statistical analyses show that the life spans of the both sexes irradiated at 20 mGy/day (p<0.0001) and of females irradiated at 1 mGy/day (p<0.05) were significantly shorter than those of the control group. There was no evidence of lengthened life span in mice continuously exposed to very low dose-rates of gama-rays. Pathodological examinations showed that the most frequently observed lethal neoplasms in males were malignant lymphomas, liver, lung, and soft tissue neoplasms, whereas, in females, malignant lymphomas and soft tissue neoplasms were common. No significant difference in the causes of death and mortality rates between groups. Hematopoietic neoplasms (malignant lymphoma and myeloid leukemia), liver, lung and soft tissue neoplasms, showed a tendency to appear at a younger age in both sexes irradiated at 20 mGy/day. Experiment 2: effects on the progeny of chronic low dose-rate gamma-ray irradiated SPF mice: preliminary study. No significant difference was observed between non-irradiated group and irradiated group with regards to litter size, sex ratio and causes of death in F1 and F2 mice. (author)

  15. Analysis of chromosomal abnormalities: a study of partial exposure to X-rays

    International Nuclear Information System (INIS)

    Andrade, Aida M.G. de; Mendes, Mariana E.; Mendonça, Julyanne C.G.; Melo, Laís; Hwang, Suy; Santos, Neide; Lima, Fabiana F. de; Centro Regional de Ciências Nucleares; Universidade Federal de Pernambuco

    2017-01-01

    Biological dosimetry is used in case of supposed accidental overexposure. The most commonly used biomarkers for assessing the absorbed dose are unstable chromosomal abnormalities. In a case of a partial body exposure, the frequencies of those abnormalities varies according to the area of the exposed body and may be substantially different from a total exposure of the body with an identical dose. The present study aimed to evaluate the frequency of chromosomal changes simulating, with blood samples, partial (25%, 50%) and full body irradiation (100%) in X-ray beam. The irradiation was performed at Metrology Service (CRCN-NE / CNEN) with a bundle of 250kVp X-rays, resulting in the absorbed dose of 1.0 Gy. Prior to obtain the metaphases, irradiated blood was mixed with non-irradiated blood, and then the mitotic metaphases for the chromosomal analyzes were obtained by culturing lymphocytes and the slides were stained with 5% Giemsa. It was observed that there was an increase in dicentric frequency when the dose percentage increases in both subjects (0.024 and 0.049 in subject 1 and 0.016 and 0.038 in subject 2) after irradiation. The cellular distribution was 'contaminated' only at dose 25% of the first individual who had a prolongation of the distribution. The Qdr and Dolphin methods were used to estimate partial absorbed dose, but the Qdr method was not efficient and whereas the Dolphin method was efficient when the individual had a prolonged cell distribution. It is necessary to increase the number of observations to be sure of the observed behaviors. (author)

  16. Analysis of chromosomal abnormalities: a study of partial exposure to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Aida M.G. de; Mendes, Mariana E.; Mendonça, Julyanne C.G.; Melo, Laís; Hwang, Suy; Santos, Neide; Lima, Fabiana F. de, E-mail: aidamgandrade@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Centro Regional de Ciências Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Universidade Federal de Pernambuco (UFPE),Recife (Brazil). Centro de Biociências. Departamento de Genética

    2017-11-01

    Biological dosimetry is used in case of supposed accidental overexposure. The most commonly used biomarkers for assessing the absorbed dose are unstable chromosomal abnormalities. In a case of a partial body exposure, the frequencies of those abnormalities varies according to the area of the exposed body and may be substantially different from a total exposure of the body with an identical dose. The present study aimed to evaluate the frequency of chromosomal changes simulating, with blood samples, partial (25%, 50%) and full body irradiation (100%) in X-ray beam. The irradiation was performed at Metrology Service (CRCN-NE / CNEN) with a bundle of 250kVp X-rays, resulting in the absorbed dose of 1.0 Gy. Prior to obtain the metaphases, irradiated blood was mixed with non-irradiated blood, and then the mitotic metaphases for the chromosomal analyzes were obtained by culturing lymphocytes and the slides were stained with 5% Giemsa. It was observed that there was an increase in dicentric frequency when the dose percentage increases in both subjects (0.024 and 0.049 in subject 1 and 0.016 and 0.038 in subject 2) after irradiation. The cellular distribution was 'contaminated' only at dose 25% of the first individual who had a prolongation of the distribution. The Qdr and Dolphin methods were used to estimate partial absorbed dose, but the Qdr method was not efficient and whereas the Dolphin method was efficient when the individual had a prolonged cell distribution. It is necessary to increase the number of observations to be sure of the observed behaviors. (author)

  17. Radiation exposure of the UK population from medical and dental x-ray examinations

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.F.

    2002-03-01

    Knowledge of recent trends in the radiation doses from x-ray examinations and their distribution for the UK population provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimise the protection of the population in a cost-effective manner. In this report, the results of a recent survey of the frequency of medical and dental x-ray examinations in the UK and contemporary data on the radiation doses typically received by patients, are used to assess trends in the extent and the pattern of the population exposure. Individual patient doses, expressed in terms of the effective dose, range from a few microsieverts for simple radiographic examinations of the teeth, limbs or chest to tens of millisieverts for prolonged fluoroscopic procedures or some computed tomography (CT) examinations. A total of about 41.5 million medical and dental x-ray examinations are now conducted each year in the UK (0.70 examination per head of population) resulting in an annual per caput effective dose of 330 μSv. This is not significantly different from the previous rough estimate of 350 μSv for 1991. However, over the last ten years CT has more than doubled its contribution and is now responsible for 40% of the total dose to the population from medical x-rays. In contrast, the contribution from conventional radiographic and fluoroscopic examinations has nearly halved to about 44%. Interventional and angiographic procedures together contribute the remaining 16%. The annual per caput dose of 330 μSv is low in comparison with other countries having similarly developed systems of health care. This is due to both a lower frequency of x-ray examinations per head of population and generally lower doses in the UK than in other developed countries. However, the much increased contributions of CT, angiography and interventional procedures to the UK population dose indicate an urgent need to develop radiation protection and optimisation activities for

  18. Neutron and gamma-ray dose-rates from the Little Boy replica

    International Nuclear Information System (INIS)

    Plassmann, E.A.; Pederson, R.A.

    1984-01-01

    We report dose-rate information obtained at many locations in the near vicinity of, and at distances out to 0.64 km from, the Little Boy replica while it was operated as a critical assembly. The measurements were made with modified conventional dosimetry instruments that used an Anderson-Braun detector for neutrons and a Geiger-Mueller tube for gamma rays with suitable electronic modules to count particle-induced pulses. Thermoluminescent dosimetry methods provide corroborative data. Our analysis gives estimates of both neutron and gamma-ray relaxation lengths in air for comparison with earlier calculations. We also show the neutron-to-gamma-ray dose ratio as a function of distance from the replica. Current experiments and further data analysis will refine these results. 7 references, 8 figures

  19. The last generation of contamination and exposure rate meters and monitors designed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Koturovic, A.M.; Sobajic, M.V.; Smelcerovic, M.A.; Damljanovic, D.D.; Drndarevic, V.R.

    1989-01-01

    The last generation of contamination and exposure rate meters and monitors designed and produced in Boris Kidric Institute, presented in this paper, are digital survey instruments. The common principle of these instruments is the 'simple precision' concept, i.e. predetermined time pulse counting. This principle is discussed and basic structure of these instruments is shown with their possibilities and features (author)

  20. The Importance of Corporate Foreign Debt in Managing Exchange Rate Exposure in Non-Financial Companies

    DEFF Research Database (Denmark)

    Aabo, Tom

    2006-01-01

    This empirical study of the exchange rate exposure management of Danish non-financial firms listed on the Copenhagen Stock Exchange shows that debt denominated in foreign currency (foreign debt) is a very important alternative to the use of currency derivatives. The results show that the relative...

  1. Assessment of natural radiation exposure and radon exhalation rates from the soil of Islamabad District of Pakistan

    International Nuclear Information System (INIS)

    Mujahid, S.A.

    2007-01-01

    Complete text of publication follows. The earth's crust is a main source of natural radionuclides in soils and rocks. The specific levels of background gamma radiation depend upon the geological composition of each lithologically separated area, and the content of the rock from which the soils originate the radioactive elements of 226Rn, 232Th and 40K. These naturally occurring radionuclides of terrestrial origin in soil can be a source of external radiation exposure through the gamma ray emission whereas internal exposure occurs through the inhalation of radon gas. The measurements of natural radioactivity and the assessment of radiological hazards in the soil samples of Islamabad district of Pakistan have been carried out using High Purity Germanium (HPGe) detector. The radon exhalation rates from these samples have also been estimated employing the 'closed-can' technique of passive dosimeters. The measured activities of 226Ra, 232Th and 40K were found in the range 14 - 30, 18 - 40 and 301 - 655 Bq.kg-1. The annual effective dose was calculated in the range 0.15 - 0.31 mSv. The values of external and internal hazard indices were less than 1. The radon exhalation rates these areas were found in the range 200 - 345 mBq.m-2h-1.

  2. Low-dose CT of the paranasal sinuses. Minimizing X-ray exposure with spectral shaping

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, Wolfgang [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany); Radiological Institute, Erlangen (Germany); May, Matthias; Saake, Marc; Brand, Michael; Uder, Michael; Lell, Michael [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany)

    2016-11-15

    Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192 x 0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 x 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDI{sub vol} 1.2 mGy vs. 4.4 mGy, p < 0.001). Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. (orig.)

  3. Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study

    International Nuclear Information System (INIS)

    Haeusler, Uwe; Brix, Gunnar; Czarwinski, Renate

    2009-01-01

    The purpose of this study was to analyse the radiation exposure of medical staff from interventional x-ray procedures. Partial-body dose measurements were performed with thermoluminescent dosimeters (TLD) in 39 physicians and nine assistants conducting 73 interventional procedures of nine different types in 14 hospitals in Germany. Fluoroscopy time and the dose-area product (DAP) were recorded too. The median (maximum) equivalent body dose per procedure was 16 (2,500) μSv for an unshielded person; the partial-body dose per procedure was 2.8 (240) μSv to the eye lens, 4.1 (730) μSv to the thyroid, 44 (1,800) μSv to one of the feet and 75 (13,000) μSv to one of the hands. A weak correlation between fluoroscopy time or DAP and the mean TLD dose was observed. Generally, the doses were within an acceptable range from a radiation hygiene point of view. However, relatively high exposures were measured to the hand in some cases and could cause a partial-body dose above the annual dose limit of 500 mSv. Thus, the use of finger dosimeters is strongly recommended. (orig.)

  4. New results regarding gonadal exposure in urologic X-ray diagnostics

    International Nuclear Information System (INIS)

    Barke, R.

    1977-01-01

    In a dosimetric study the radiation exposure of the gonads of 130 patients is determined with condenser ionization chambers in applying intravenous urography according to the valid examination standard of the Society of Medical radiology of the GDR. Shielding the gonads with 2 mm lead equivalent the gonad dose of men is less than 30 mrem, but more than 850 mrem without shielding. The gonad dose of women computationally determined from measurements of the surface dose, is about 1,200 mrem. As the radiation exposure due to each individual radiograph was recorded, the influencing factors (film size, distance of the lower field margin from the gonads) can be determined. For the statistically significant correlation between body weight and gonad dose regression equations are given which, with standard X-ray examinations, make it possible to calculate the gonad dose for the individual case with a high degree of certainty. The analysis of intravenous urographic examinations shows that there is a greater share of female patients because this type of examination is often used as an additional diagnostic procedure in case of gynaecologic diseases. Problems of exact dosimetry at the ovary can hardly be solved

  5. Cytogenetic analysis in peripheral blood lymphocytes after arteriography (exposure to X-rays and contrast medium)

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Popova, L.; Hristova, R.; Hadjidekov, V.

    2006-01-01

    Full text: The purpose of our study is to investigate the cytogenetic effects in peripheral blood lymphocytes of 29 patients who had undergone diagnostic angiography. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13 and 68 years). Cytogenetic analysis was performed in peripheral lymphocytes before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03 - 0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency was used as biomarkers of genotoxicity. The estimated frequency of chromosomal aberrations and micronuclei in peripheral blood lymphocytes of patients after arteriography examination is significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations nearly double after examination and remained constant at 24h analysis. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase of the cytogenetic injury in peripheral blood lymphocytes

  6. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  7. Dose Rate and Mass Attenuation Coefficients of Gamma Ray for Concretes

    CERN Document Server

    Abdel-Latif, A A; Kansouh, W A; El-Sayed, F H

    2003-01-01

    This work is concerned with the study of the leakage gamma ray dose and mass attenuation coefficients for ordinary, basalt and dolomite concretes made from local ores. Concretes under investigation were constructed from gravel, basalt and dolomite ores, and then reconstructed with the addition of 3% steel fibers by weight. Measurements were carried out using a collimated beam from sup 6 sup 0 Co gamma ray source and sodium iodide (3x3) crystal with the genie 2000 gamma spectrometer. The obtained fluxes were transformed to gamma ray doses and displayed in the form of gamma ray dose rates distribution. The displayed curves were used to estimate the linear attenuation coefficients (mu), the relaxation lengths (lambda), half value layer (t sub 1 /2) and tenth value layer (t sub 1 /10). Also, The total mass attenuation coefficients of gamma ray have been calculated to the concerned concretes using XCOM (version 3.1) program and database elements cross sections from Z=1 to 100 at energies from 10 keV to 100 MeV. In...

  8. In-situ buildup of cosmogenic isotopes at the earth`s surface: measurement of erosion rates and exposure times

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, L K; Allan, G L; Stone, J O.H.; Evans, J M; Cresswell, R G; Ophel, T R [Australian National Univ., Canberra, ACT (Australia)

    1994-12-31

    Cosmic rays produce a number of nuclides in rocks that can be used to determine the geomorphic history of surfaces. The most useful are the radioactive isotopes {sup 10}Be (t{sub 1/2} = 1.5Ma), {sup 26}Al (0.7Ma) and {sup 36}Cl (0.3Ma). Within the top 2m of the surface, these are produced principally by fast neutrons. At greater depths, production is dominated by the capture of negative muons. Measurements of a single nuclide produced in situ can be used to determine total exposure times or erosion rates. The use of multiple nuclides with different half-lives makes it possible to determine more complex histories, such as exposures interrupted by periods of burial. At the ANU, all three of the isotopes above are being used to study a variety of problems in geomorphology and paleoclimatology, although to date, most of the work has concentrated on {sup 36}Cl. The accumulation of cosmogenic {sup 36}Cl in calcite (CaCO{sub 3}) provides a means of measuring erosion rates on limestone surfaces. Sensitivity is achieved over a wide range of erosion rates due to the high production rate of {sup 36}Cl in calcite (typically greater than 30 atoms/g/yr) and a detection limit of ca. 5000 atoms/g attainable with the ANU AMS system. The method is simplified by the predominance of Ca reactions (principally spallation) over other sources of {sup 36}Cl in calcite, and the ease of sample preparation. This presentation discuss the results of measurements of {sup 36}Cl in calcite from limestone samples from Australia and Papua New Guinea. Erosion rates derived from these measurements range from 3 microns per year (Australia) to over 200 microns per year in the New Guinea highlands. 3 refs.

  9. In-situ buildup of cosmogenic isotopes at the earth's surface: measurement of erosion rates and exposure times

    International Nuclear Information System (INIS)

    Fifield, L.K.; Allan, G.L.; Stone, J.O.H.; Evans, J.M.; Cresswell, R.G.; Ophel, T.R.

    1993-01-01

    Cosmic rays produce a number of nuclides in rocks that can be used to determine the geomorphic history of surfaces. The most useful are the radioactive isotopes 10 Be (t 1/2 = 1.5Ma), 26 Al (0.7Ma) and 36 Cl (0.3Ma). Within the top 2m of the surface, these are produced principally by fast neutrons. At greater depths, production is dominated by the capture of negative muons. Measurements of a single nuclide produced in situ can be used to determine total exposure times or erosion rates. The use of multiple nuclides with different half-lives makes it possible to determine more complex histories, such as exposures interrupted by periods of burial. At the ANU, all three of the isotopes above are being used to study a variety of problems in geomorphology and paleoclimatology, although to date, most of the work has concentrated on 36 Cl. The accumulation of cosmogenic 36 Cl in calcite (CaCO 3 ) provides a means of measuring erosion rates on limestone surfaces. Sensitivity is achieved over a wide range of erosion rates due to the high production rate of 36 Cl in calcite (typically greater than 30 atoms/g/yr) and a detection limit of ca. 5000 atoms/g attainable with the ANU AMS system. The method is simplified by the predominance of Ca reactions (principally spallation) over other sources of 36 Cl in calcite, and the ease of sample preparation. This presentation discuss the results of measurements of 36 Cl in calcite from limestone samples from Australia and Papua New Guinea. Erosion rates derived from these measurements range from 3 microns per year (Australia) to over 200 microns per year in the New Guinea highlands. 3 refs

  10. In-situ buildup of cosmogenic isotopes at the earth`s surface: measurement of erosion rates and exposure times

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, L.K.; Allan, G.L.; Stone, J.O.H.; Evans, J.M.; Cresswell, R.G.; Ophel, T.R. [Australian National Univ., Canberra, ACT (Australia)

    1993-12-31

    Cosmic rays produce a number of nuclides in rocks that can be used to determine the geomorphic history of surfaces. The most useful are the radioactive isotopes {sup 10}Be (t{sub 1/2} = 1.5Ma), {sup 26}Al (0.7Ma) and {sup 36}Cl (0.3Ma). Within the top 2m of the surface, these are produced principally by fast neutrons. At greater depths, production is dominated by the capture of negative muons. Measurements of a single nuclide produced in situ can be used to determine total exposure times or erosion rates. The use of multiple nuclides with different half-lives makes it possible to determine more complex histories, such as exposures interrupted by periods of burial. At the ANU, all three of the isotopes above are being used to study a variety of problems in geomorphology and paleoclimatology, although to date, most of the work has concentrated on {sup 36}Cl. The accumulation of cosmogenic {sup 36}Cl in calcite (CaCO{sub 3}) provides a means of measuring erosion rates on limestone surfaces. Sensitivity is achieved over a wide range of erosion rates due to the high production rate of {sup 36}Cl in calcite (typically greater than 30 atoms/g/yr) and a detection limit of ca. 5000 atoms/g attainable with the ANU AMS system. The method is simplified by the predominance of Ca reactions (principally spallation) over other sources of {sup 36}Cl in calcite, and the ease of sample preparation. This presentation discuss the results of measurements of {sup 36}Cl in calcite from limestone samples from Australia and Papua New Guinea. Erosion rates derived from these measurements range from 3 microns per year (Australia) to over 200 microns per year in the New Guinea highlands. 3 refs.

  11. Tritium β-radiation induction of chromosomal damage: a calibration curve for low dose, low dose rate exposures of human cells to tritiated water

    International Nuclear Information System (INIS)

    Morrison, D.P.; Gale, K.L.; Lucas, J.N.

    1997-01-01

    Radiation exposures from tritium contribute to the occupational radiation exposures associated with CANDU reactors. Tritiated water is of particular interest since it is readily taken up by human cells and its elimination from the body, and, consequently, the radiation exposure of the cells, is spread over a period of days. Occupational exposures to tritiated water result in what are effectively chronic β-radiation exposures. The doses and dose rates ordinarily used in the definition of cellular responses to radiation in vitro, for use in biological dosimetry (the assessment of radiation exposures based on the observed levels of changes in the cells of exposed individuals), are usually much higher than for most occupational exposures and involve radiations other than tritium β-rays. As a result, their use in assessing the effects from tritiated water exposures may not be appropriate. We describe here an in vitro calibration curve for chronic tritium β-radiation induction of reciprocal chromosomal translocations in humn peripheral blood lymphocytes (PBLs) for use in biodosimetry. (author)

  12. Level of radiation exposure to staff in X-ray diagnosis

    International Nuclear Information System (INIS)

    Zol'nikova, N.I.; Moisejtsev, P.I.; Trunov, B.V.

    1976-01-01

    In modern radiological service departments the dose rates at working placesof medical aff directly engaged in diagnostic work were found to range from 7 to 100 mR/h during fuoroscopand up to 1,200 mR/h during roentgenoscopy and ray inematography, respectively. Durig fluocopic work in the operating theatre the monthly doses to staff ranged from 100 to 380 mRfor sugeos and anaesthesists, from 110 to 225 mR for surgical nurses, and from5to 30 roranhesia nurses. AUTHOR)

  13. [Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination].

    Science.gov (United States)

    Miyajima, Ryuichi; Fujibuchi, Toshioh; Miyachi, Yusuke; Tateishi, Satoshi; Uno, Yoshinori; Amakawa, Kazutoshi; Ohura, Hiroki; Orita, Shinichi

    2018-01-01

    Medical staffs like radiological technologists, doctors, and nurses are at an increased risk of exposure to radiation while assisting the patient in a position or monitor contrast medium injection during computed tomography (CT). However, methods to protect medical staff from radiation exposure and protocols for using radiological protection equipment have not been standardized and differ among hospitals. In this study, the distribution of scattered X-rays in a CT room was measured by placing electronic personal dosimeters in locations where medical staff stands beside the CT scanner gantry while assisting the patient and the exposure dose was measured. Moreover, we evaluated non-uniform exposure and revealed effective techniques to reduce the exposure dose to medical staff during CT. The dose of the scattered X-rays was the lowest at the gantry and at the examination table during both head and abdominal CT. The dose was the highest at the trunk of the upper body of the operator corresponding to a height of 130 cm during head CT and at the head corresponding to a height of 150 cm during abdominal CT. The maximum dose to the crystalline lens was approximately 600 μSv during head CT. We found that the use of volumetric CT scanning and X-ray protective goggles, and face direction toward the gantry reduced the exposure dose, particularly to the crystalline lens, for which lower equivalent dose during CT scan has been recently recommended in the International Commission on Radiological Protection Publication 118.

  14. Low-dose-rate radiation exposure leads to testicular damage with decreases in DNMT1 and HDAC1 in the murine testis

    International Nuclear Information System (INIS)

    Gong, Eun Ji; Son, Tae Gen; Yang, Kwangmo; Heo, Kyu; Kim, Joong Sun; Shin, In Sik

    2014-01-01

    This study examined the effects of continuous low-dose-rate radiation exposure (3.49 mGy/h) of gamma rays on mice testicles. C57BL/6 mice were divided into sham and radiation groups (n = 8 each), and were exposed to either sham irradiation or 2 Gy for 21 days, 0.2 Gy for 2 days, or 0.02 Gy for 6 h of low-dose-rate irradiation. Testicular weight, seminiferous tubular diameter, and seminiferous epithelial depth were significantly decreased in the mice irradiated with 2 Gy at 1 and 9 days after exposure. Moreover, the low-dose-rate radiation exposure induced an increase in malondialdehyde levels, and a decrease in superoxide dismutase activity in the testis of mice irradiated with 2 Gy at 1 and 9 days after exposure. The sperm count and motility in the epididymis also decreased in mice irradiated with 2 Gy at 1 and 9 days after exposure, whereas there was no significant effect on the proportion of abnormal sperm. The expressions of DNA methlytransferases-1 and histone deacetylases 1 in testes irradiated with 2 Gy were significantly decreased compared with the sham group. In conclusion, the damage exerted on the testes and epididymis largely depended on the total dose of low-dose-rate radiation. (author)

  15. A review of air exchange rate models for air pollution exposure assessments.

    Science.gov (United States)

    Breen, Michael S; Schultz, Bradley D; Sohn, Michael D; Long, Thomas; Langstaff, John; Williams, Ronald; Isaacs, Kristin; Meng, Qing Yu; Stallings, Casson; Smith, Luther

    2014-11-01

    A critical aspect of air pollution exposure assessments is estimation of the air exchange rate (AER) for various buildings where people spend their time. The AER, which is the rate of exchange of indoor air with outdoor air, is an important determinant for entry of outdoor air pollutants and for removal of indoor-emitted air pollutants. This paper presents an overview and critical analysis of the scientific literature on empirical and physically based AER models for residential and commercial buildings; the models highlighted here are feasible for exposure assessments as extensive inputs are not required. Models are included for the three types of airflows that can occur across building envelopes: leakage, natural ventilation, and mechanical ventilation. Guidance is provided to select the preferable AER model based on available data, desired temporal resolution, types of airflows, and types of buildings included in the exposure assessment. For exposure assessments with some limited building leakage or AER measurements, strategies are described to reduce AER model uncertainty. This review will facilitate the selection of AER models in support of air pollution exposure assessments.

  16. Spatial variation of natural terrestrial γ-ray dose rates in Brunei

    International Nuclear Information System (INIS)

    Hu, S.J.; Lai, K.K.

    1998-01-01

    A carborne survey of natural terrestrial y-ray dose rates along the main roads of the western part of Brunei Darussalam was carried out using two portable type 1.5'φx4' NaI(T1) and 1'φx2' NaI(T1) scintillation counters. A series of semicontinuous count rates measurements were performed inside a moving vehicle. This yielded equal-distance data which were analysed statistically to obtain the spatial variation of the natural terrestrial γ-ray dose rates. The equal-distance data of dose rates were obtained by correcting for shielding effect of the car. The thickness of the pavement and the contribution from the pavement material were estimated from a correlation curve between the dose rates measured on pavements and on the nearby soils. A spectral analysis of the equal-distance data enabled us to clarify the structure of the spatial variation in dose rates. The data could be reasonably smoothened by removing the random noise components in a higher wave number region

  17. Exposure Time Distributions reveal Denitrification Rates along Groundwater Flow Path of an Agricultural Unconfined Aquifer

    Science.gov (United States)

    Kolbe, T.; Abbott, B. W.; Thomas, Z.; Labasque, T.; Aquilina, L.; Laverman, A.; Babey, T.; Marçais, J.; Fleckenstein, J. H.; Peiffer, S.; De Dreuzy, J. R.; Pinay, G.

    2016-12-01

    Groundwater contamination by nitrate is nearly ubiquitous in agricultural regions. Nitrate is highly mobile in groundwater and though it can be denitrified in the aquifer (reduced to inert N2 gas), this process requires the simultaneous occurrence of anoxia, an electron donor (e.g. organic carbon, pyrite), nitrate, and microorganisms capable of denitrification. In addition to this the ratio of the time groundwater spent in a denitrifying environment (exposure time) to the characteristic denitrification reaction time plays an important role, because denitrification can only occur if the exposure time is longer than the characteristic reaction time. Despite a long history of field studies and numerical models, it remains exceedingly difficult to measure or model exposure times in the subsurface at the catchment scale. To approach this problem, we developed a unified modelling approach combining measured environmental proxies with an exposure time based reactive transport model. We measured groundwater age, nitrogen and sulfur isotopes, and water chemistry from agricultural wells in an unconfined aquifer in Brittany, France, to quantify changes in nitrate concentration due to dilution and denitrification. Field data showed large differences in nitrate concentrations among wells, associated with differences in the exposure time distributions. By constraining a catchment-scale characteristic reaction time for denitrification with water chemistry proxies and exposure times, we were able to assess rates of denitrification along groundwater flow paths. This unified modeling approach is transferable to other catchments and could be further used to investigate how catchment structure and flow dynamics interact with biogeochemical processes such as denitrification.

  18. On scaling cosmogenic nuclide production rates for altitude and latitude using cosmic-ray measurements

    Science.gov (United States)

    Desilets, Darin; Zreda, Marek

    2001-11-01

    The wide use of cosmogenic nuclides for dating terrestrial landforms has prompted a renewed interest in characterizing the spatial distribution of terrestrial cosmic rays. Cosmic-ray measurements from neutron monitors, nuclear emulsions and cloud chambers have played an important role in developing new models for scaling cosmic-ray neutron intensities and, indirectly, cosmogenic production rates. Unfortunately, current scaling models overlook or misinterpret many of these data. In this paper, we describe factors that must be considered when using neutron measurements to determine scaling formulations for production rates of cosmogenic nuclides. Over the past 50 years, the overwhelming majority of nucleon flux measurements have been taken with neutron monitors. However, in order to use these data for scaling spallation reactions, the following factors must be considered: (1) sensitivity of instruments to muons and to background, (2) instrumental biases in energy sensitivity, (3) solar activity, and (4) the way of ordering cosmic-ray data in the geomagnetic field. Failure to account for these factors can result in discrepancies of as much as 7% in neutron attenuation lengths measured at the same location. This magnitude of deviation can result in an error on the order of 20% in cosmogenic production rates scaled from 4300 m to sea level. The shapes of latitude curves of nucleon flux also depend on these factors to a measurable extent, thereby causing additional uncertainties in cosmogenic production rates. The corrections proposed herein significantly improve our ability to transfer scaling formulations based on neutron measurements to scaling formulations applicable to spallation reactions, and, therefore, constitute an important advance in cosmogenic dating methodology.

  19. Studies of a Linac Driver for a High Repetition Rate X-Ray FEL

    International Nuclear Information System (INIS)

    Venturini, M.; Corlett, J.; Doolittle, L.; Filippetto, D.; Papadopoulos, C.; Penn, G.; Prosnitz, D.; Qiang, J.; Reinsch, M.; Ryne, R.; Sannibale, F.; Staples, J.; Wells, R.; Wurtele, J.; Zolotorev, M.; Zholents, A.

    2011-01-01

    We report on on-going studies of a superconducting CW linac driver intended to support a high repetition rate FEL operating in the soft x-rays spectrum. We present a pointdesign for a 1.8 GeV machine tuned for 300 pC bunches and delivering low-emittance, low-energy spread beams as needed for the SASE and seeded beamlines.

  20. Air pollution and heart rate variability: effect modification by chronic lead exposure.

    Science.gov (United States)

    Park, Sung Kyun; O'Neill, Marie S; Vokonas, Pantel S; Sparrow, David; Wright, Robert O; Coull, Brent; Nie, Huiling; Hu, Howard; Schwartz, Joel

    2008-01-01

    Outdoor air pollution and lead exposure can disturb cardiac autonomic function, but the effects of both these exposures together have not been studied. We examined whether higher cumulative lead exposures, as measured by bone lead, modified cross-sectional associations between air pollution and heart rate variability among 384 elderly men from the Normative Aging Study. We used linear regression, controlling for clinical, demographic, and environmental covariates. We found graded, significant reductions in both high-frequency and low-frequency powers of heart rate variability in relation to ozone and sulfate across the quartiles of tibia lead. Interquartile range increases in ozone and sulfate were associated respectively, with 38% decrease (95% confidence interval = -54.6% to -14.9%) and 22% decrease (-40.4% to 1.6%) in high frequency, and 38% decrease (-51.9% to -20.4%) and 12% decrease (-28.6% to 9.3%) in low frequency, in the highest quartile of tibia lead after controlling for potential confounders. We observed similar but weaker effect modification by tibia lead adjusted for education and cumulative traffic (residuals of the regression of tibia lead on education and cumulative traffic). Patella lead modified only the ozone effect on heart rate variability. People with long-term exposure to higher levels of lead may be more sensitive to cardiac autonomic dysfunction on high air pollution days. Efforts to understand how environmental exposures affect the health of an aging population should consider both current levels of pollution and history of lead exposure as susceptibility factors.

  1. In-situ real time measurements of net erosion rates of copper during hydrogen plasma exposure

    Science.gov (United States)

    Kesler, Leigh; Wright, Graham; Peterson, Ethan; Whyte, Dennis

    2013-10-01

    In order to properly understand the dynamics of net erosion/deposition in fusion reactors, such as tokamaks, a diagnostic measuring the real time rates of net erosion/deposition during plasma exposure is necessary. The DIONISOS experiment produces real time measurements of net erosion/deposition by using Rutherford backscattering spectroscopy (RBS) ion beam analysis simultaneously with plasma exposure from a helicon plasma source. This in-situ method improves on ex-situ weight loss measurements by allowing measurement of possible synergistic effects of high ion implantation rates and net erosion rate and by giving a real time response to changes in plasma parameters. Previous work has validated this new technique for measuring copper (Cu) erosion from helium (He) plasma ion bombardment. This technique is now extended to measure copper erosion due to deuterium and hydrogen plasma ion exposure. Targets used were a 1.5 μm Cu layer on an aluminum substrate. Cu layer thickness is tracked in real time using 1.2 MeV proton RBS. Measured erosion rates will be compared to results from literature and He erosion rates. Supported by US DoE award DE-SC00-02060.

  2. Water requirements and drinking rates of homing pigeons: A consideration for exposure risk of migratory birds.

    Science.gov (United States)

    Perez, Cristina R; Moye, John K; Pritsos, Chris A

    2017-09-01

    Access to water along a bird's migratory flyway is essential during the vital process of migration. Because of the scarcity of water in some environments, there is potential for migratory birds to encounter and drink from contaminated bodies of water. Ingestion of contaminated water may cause injury and compromise flying ability, leading to a disruption of migration. To determine injury to birds from potential exposure, it is essential to know not only the concentration of a given contaminant in the water but also the quantity and rate of water consumption by the birds. Homing pigeons (Columba livia) were used in a series of experiments to determine differences in drinking behavior after various flights and after periods of resting. Results from the present study demonstrate that homing pigeons' water consumption is dramatically different when assessed according to activity, flight distance, and time elapsed after flight. This suggests that the drinking rates of birds during migration are extremely important and much greater than estimated using traditional exposure assessment procedures. Thus, exposure to contaminants via drinking water may be greatly underestimated, and the rate of water consumption should be considered when estimating potential exposure risk to avian species. Integr Environ Assess Manag 2017;13:870-876. © 2017 SETAC. © 2017 SETAC.

  3. The effects of exposure to environmental factors on Heart Rate Variability: An ecological perspective

    International Nuclear Information System (INIS)

    Schnell, Izhak; Potchter, Oded; Epstein, Yoram; Yaakov, Yaron; Hermesh, Hagai; Brenner, Shmuel; Tirosh, Emanuel

    2013-01-01

    The impact of human exposure to environmental factors on Heart Rate Variability (HRV) was examined in the urban space of Tel-Aviv-Jaffa. Four environmental factors were investigated: thermal and social loads; CO concentrations and noise. Levels of HRV are explained mainly by subjective social stresses, noise and CO. The most interesting result is the fact that while subjective social stress and noise increase HRV, low levels of CO are reducing HRV to some extent moderating the impact of subjective social stress and noise. Beyond the poisoning effect of CO and the fact that extremely low levels of HRV associated with high dozes of CO increase risk for life, low levels of CO may have a narcotic effect, as it is measured by HRV. The effects of thermal loads on HRV are negligible probably due to the use of behavioral means in order to neutralize heat and cold effects. -- Highlights: ► The impact of human exposure to environmental factors on Heart Rate Variability (HRV) was examined. ► Previous studies measured human exposure to pollution by fixed monitoring stations. ► This study measured actual personal exposure by mini sensors. ► High level of subjective social load and noise increase HRV. ► Low levels of CO may have a narcotic effect, as it is measured by HRV. -- The research focuses on the effects of environmental factors; noise, subjective social stress, thermal load and CO on Heart Rate Variability

  4. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    Science.gov (United States)

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-05-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.

  5. Dose-rate models for human survival after exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Jones, T.D.; Morris, M.D.; Young, R.W.

    1987-01-01

    This paper reviews new estimates of the LD 50 in man by Mole and by Rotblat, the biological processes contributing to hematologic death, the collection of animal experiments dealing with hematologic death, and the use of regression analysis to make new estimates of human mortality based on all relevant animal studies. Regression analysis of animal mortality data has shown that mortality is dependent strongly on dose rate, species, body weight, and time interval over which the exposure is delivered. The model has predicted human LD 50 s of 194, 250, 310, and 360 rad to marrow when the exposure time is a minute, an hour, a day, and a week, respectively

  6. Estimation of exposure to 222Rn from the excretion rates of 21πPb

    International Nuclear Information System (INIS)

    Holtzman, R.B.; Rundo, J.

    1981-01-01

    A model is proposed with which estimates of exposure to 227 Rn and its daughter products may be made from urinary excretion rates of 210 Pb. It is assumed that 20% of all the 210 Pb inhaled reaches the blood and that 50% of the endogenous excretion is through the urine. The estimates from the model are compared with the results of measurements on a subject residing in a house with high levels of radon. Whole body radioactivity and excretion data were consistent with the model, but the estimates of exposure (WL) were higher than those measured with an Environmental Working Level Monitor

  7. Dose-rate models for human survival after exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Jones, T.D.; Morris, M.D.; Young, R.W.

    1986-01-01

    This paper reviews new estimates of the L 50 in man by Mole and by Rotblat, the biological processes contributing to hematologic death, the collection of animal experiments dealing with hematologic death, and the use of regression analysis to make new estimates of human mortality based on all relevant animal studies. Regression analysis of animal mortality data has shown that mortality is dependent strongly on dose rate, species, body weight, and time interval over which the exposure is delivered. The model has predicted human LD 50 s of 194, 250, 310, and 360 rad to marrow when the exposure time is a minute, an hour, a day, and a week, respectively

  8. Relationship between terrestrial gamma ray dose rates and geology of Awaji Island in Hyogo Prefecture

    International Nuclear Information System (INIS)

    Shibayama, Motohiko; Hiraoka, Yoshitsugu; Ikeda, Tadashi; Terado, Shin

    2004-01-01

    In order to clarify the relationship between terrestrial gamma ray dose rates and surface geology, measurements were carried out for the entire part f Awaji Island in Hyogo Prefecture. The results of analysis were summarized as follows. (1) The mean value for each geology was nearly the same as that in the whole of Japan. (2) The granitic rocks can be divided into three groups, based on their stages of intrusion (Tainsyo, 1985). the dose rate levels for granitic rocks increased from fast stage over third stage. (author)

  9. Determination of Corrosion Rate of Artificial Bone Made of Metal at Different pH Conditions using X-Ray Radiography

    Science.gov (United States)

    Sutikno; Handayani, L.; Edi, S. S.; Susilo; Elvira

    2018-03-01

    The purpose of this research is to observe the mechanism and the rate of corrosion of artificial bone made of metal by using x-ray radiography technique. Artificial bones can be made of metallic materials and composites which are biomaterials. The most commonly used metal for bone graft is stainless steel. The interaction between artificial bone and human tissue will have important medical impacts that need to be observed and examined. This interaction can be a mechanical or chemical interaction. X-ray radiography technique is selected because it uses non-destructive method. This method is done by x-ray radiation exposure on the observed body part. The bone density and bone fracture can be seen on the resulted radiographic film or image on the monitor screen.

  10. Disorders of oxidation homeostasis in the blood and organs of rats under the influence of external x-ray exposure

    International Nuclear Information System (INIS)

    Uzlenkova, N.Je.

    2009-01-01

    The study was performed in the blood and organs (lungs and skin) of male rats weighing 160-180 g. Single external x-ray exposure to minimal and medial lethal doses causes stable disorders in oxidation homeostasis resulting in peroxidation state and development of chronic oxidative stress in the organism of the exposed rats.

  11. The Rates of Type I X-ray Bursts from Transients Observed with RXTE: Evidence for Black Hole Event Horizons

    Science.gov (United States)

    Remillard, R. A.; Lin, D.; Cooper, R. L.; Narayan, R.

    2005-12-01

    We measure the rates of type I X-ray bursts from a likely complete sample of 37 non-pulsing Galactic X-ray transients observed with the RXTE ASM during 1996-2004. Our strategy is to test the prevailing paradigms for these sources, which are well-categorized in the literature as either neutron-star systems or black hole candidates. Burst rates are measured as a function of the bolometric luminosity, and the results are compared with burst models for neutron stars and for heavy compact objects with a solid surface. We use augmented versions of the models developed by Narayan & Heyl (2002; 2003). For a given mass, we consider a range of conditions in both the radius and the temperature at the boundary below the accretion layer. We find 135 type I bursts in 3.7 Ms of PCA light curves for the neutron-star group, and the burst rate function is generally consistent with the model predictions for bursts from accreting neutron stars. On the other hand, none of the (20) bursts candidates passed spectral criteria for type I bursts in 6.5 Ms of PCA light curves for black-hole binaries and candidates. The burst function upper limits are inconsistent with the predictions of the burst model for heavy compact objects with a solid surface. The consistency probability is found to be below 10-7 for dynamical black-hole binaries, falling to below 10-13 for the additional exposures of black-hole candidates. These results provide indirect evidence that black holes do have event horizons. This research was supported, in part, by NASA science programs.

  12. Rating the Raters: Legal Exposure of Trustmark Authorities in the Context of Consumer Health Informatics

    Science.gov (United States)

    2000-01-01

    There are three areas of potential legal exposure for an organization such as a trustmark authority involved in e-health quality rating. First, an e-health provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on e-health data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the e-health data provider, questions may arise as to the possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations, and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, the introduction of legislation. PMID:11720941

  13. Rating the "Raters": Legal Exposure of Trustmark Authorities in the Context of Consumer Health Informatics

    Science.gov (United States)

    Terry, Nicolas P

    2000-01-01

    There are three areas of potential legal exposure for an organization such as a trustmark authority involved in ehealth quality rating. First, an ehealth provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on ehealth data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the ehealth data provider, questions may arise as to possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, legislation.

  14. Dose response relationship for unstable-type chromosome aberration rate of spleen cells from mice continuously exposed to low-dose-rate gamma-rays

    International Nuclear Information System (INIS)

    Tanaka, Kimio; Khoda, Atsushi; Ichinohe, Kazuaki; Oghiso, Yoichi

    2007-01-01

    It has been reported that people who are chronically exposed to radiation such as nuclear facility workers and medical radiologists have slightly higher incidences of chromosome aberrations than non-exposed people. However, chronological changes of chromosome aberration rates related to accumulated doses and dose-rates for low dose-rate radiation exposures have not been well studied. Precise analyses of human populations are quite limited because confounding factors influence the results. For this reason, animal experiments are important for analyses. Mice were continuously exposed to gamma-rays at 400 mGy/22 hr/day for 10 days, 20 mGy/22 hr/day for about 400 days, and 1 mGy/22 hr/day for about 615 days under SPF conditions. Chronological changes of unstable-type chromosome aberration rates of spleen cells were observed along with accumulated doses at the middle dose rate and the two low-dose rates by conventional Giemsa-staining method. Aberrations such as dicentric chromosome, ring chromosome and fragment increased in a two-phase manner within 0-1.2 Gy and 2-8 Gy at 20 mGy/22 hr/day. They slightly increased up to 0.5 Gy at 1 mGy/22 hr/day. Aberration rates for 1, 2, 8 Gy at the 20 mGy/22 hr/day and for 0.5 Gy at 1 mGy/22 hr/day were 5.1, 9.6, 13.9 and 2.2 times higher than those of age-matched, non-irradiated control mice, respectively. Chromosome aberration rates at 400 mGy/22 hr/day were 2.7 times higher than that of 20 mGy/22 hr/day for the same total dose of 1.2 Gy. The results that unstable-type chromosome aberrations increased with accumulated dose of the low-dose rate radiation will be important to establish biological dosimetry for people who are chronically exposed to radiation. (author)

  15. Gamma-ray dose rate in air on the subway lines in Tokyo metropolitan area

    International Nuclear Information System (INIS)

    Ogawa, Masayuki; Hosoda, Masahiro; Ogashiwa, Susumu; Fukushi, Masahiro

    2008-01-01

    Measurements of gamma-ray dose rates in air were performed on 12 subway lines in Tokyo from the perspective of health physics, because the subways are commonly used for commuting in the Tokyo metropolitan area. The results showed that the maximum dose rate (36.5 nGy/h) was 1.6 times higher than that of the minimum one (23.3 nGy/h), and that the dose rate in the subway car was 33% lower than the outside. Also the results strongly suggested that the dose rates depend on the concentration of natural radionuclide around the subway lines and the platform structures rather than the depth. (author)

  16. Dose-rate effects and chronological changes of chromosome aberration rates in spleen cells from mice that are chronically exposed to gamma-ray at low dose rates

    International Nuclear Information System (INIS)

    Tanaka, Kimio; Kohda, Atsushi; Ichinohe, Kazuaki; Matsumoto, Tsuneya; Oghiso, Yoichi

    2006-01-01

    Dose-rate effects have not been examined in the low dose-rate regions of less than 60-600 mGy/h. Mice were chronically exposed to gamma-ray at 20 mGy/day (approximately 1 mGy/h) up to 700 days and at 1 mGy/day (approximately 0.05 mGy/h) for 500 days under SPF conditions. Chronological changes of chromosome aberration rates in spleen cells were observed along with accumulated doses at both low dose-rates. Unstable aberrations increased in a biphasic manner within 0-2 Gy and 4-14 Gy in 20 mGy/day irradiation. They slightly increased up to 0.5 Gy in 1 mGy/day irradiation. Chromosome aberration rates at 20 mGy/day and 1 mGy/day were compared at the same total doses of 0.5 Gy and 0.25 Gy. They were 2.0 vs. 0.53, and 1.0 vs. 0.47 respectively. Thus, dose-rate effects were observed in these low dose-rate regions. (author)

  17. Medicine and ionizing rays: a help sheet in analysing risks in high rate curietherapy

    International Nuclear Information System (INIS)

    Gauron, C.

    2009-01-01

    This document proposes a synthesis of useful knowledge for radioprotection in the case of high rate curietherapy. Several aspects are considered: the concerned personnel, the course of treatment procedures, the hazards, the identification of the risk associated with ionizing radiation, the risk assessment and the determination of exposure levels, the strategy to control the risks (reduction of risks, technical measures concerning the installation or the personnel, teaching and information, prevention and medical monitoring), and risk control assessment

  18. Medicine and ionizing rays: a help sheet in analysing risks in pulsed rate curietherapy

    International Nuclear Information System (INIS)

    Gauron, C.

    2009-01-01

    This document proposes a synthesis of useful knowledge for radioprotection in the case of pulsed rate curietherapy. Several aspects are considered: the concerned personnel, the course of treatment procedures, the hazards, the identification of the risk associated with ionizing radiation, the risk assessment and the determination of exposure levels, the strategy to control the risks (reduction of risks, technical measures concerning the installation or the personnel, teaching and information, prevention and medical monitoring), and risk control assessment

  19. Thermoluminescence study of X-ray irradiated muscovite mineral under various heating rate

    International Nuclear Information System (INIS)

    Kalita, J.M.; Wary, G.

    2014-01-01

    The thermoluminescence (TL) glow curves of X-ray irradiated micro-grain natural muscovite were recorded within 298–520 K at various linear heating rates (2 K/s, 4 K/s, 6 K/s, 8 K/s and 10 K/s). Natural TL of muscovite was checked, but no significant TL was observed within 298–520 K in any heating rate. Within the heating rate 2–10 K/s only a low temperature distinct peak was observed in the temperature range 348–357 K. The TL parameters such as activation energy, order of kinetic, geometrical symmetry factor and pre-exponential frequency factor were investigated from the glow peak by Peak Shape (PS) method and Computerized Glow Curve Deconvolution (CGCD) technique. At lowest heating rate the glow peak obeys non-first order kinetic and at the highest heating rate it follows the second order kinetic. The variation of peak integrals, peak maximum temperatures, FWHM and activation energy with heating rates were investigated, and the glow curves at higher rates were found to be influenced by the presence of the thermal quenching. The thermal quenching activation energy and pre-exponential factor were calculated and found to be 2.31±0.02 eV and 3.46×10 14 s −1 , respectively. -- Highlights: • Muscovite is a silicate mineral with chemical formula KAl 2 (Si 3 Al)O 10 (OH,F) 2 . • TL of natural and X-ray induced muscovite was studied under various heating rates. • TL parameters were evaluated by Peak Shape and CGCD method. • Thermal quenching parameters (W and C) of muscovite were evaluated

  20. Association of arsenic exposure with lung cancer incidence rates in the United States.

    Directory of Open Access Journals (Sweden)

    Joseph J Putila

    Full Text Available Although strong exposure to arsenic has been shown to be carcinogenic, its contribution to lung cancer incidence in the United States is not well characterized. We sought to determine if the low-level exposures to arsenic seen in the U.S. are associated with lung cancer incidence after controlling for possible confounders, and to assess the interaction with smoking behavior.Measurements of arsenic stream sediment and soil concentration obtained from the USGS National Geochemical Survey were combined, respectively, with 2008 BRFSS estimates on smoking prevalence and 2000 U.S. Census county level income to determine the effects of these factors on lung cancer incidence, as estimated from respective state-wide cancer registries and the SEER database. Poisson regression was used to determine the association between each variable and age-adjusted county-level lung cancer incidence. ANOVA was used to assess interaction effects between covariates.Sediment levels of arsenic were significantly associated with an increase in incident cases of lung cancer (P<0.0001. These effects persisted after controlling for smoking and income (P<0.0001. Across the U.S., exposure to arsenic may contribute to up to 5,297 lung cancer cases per year. There was also a significant interaction between arsenic exposure levels and smoking prevalence (P<0.05.Arsenic was significantly associated with lung cancer incidence rates in the U.S. after controlling for smoking and income, indicating that low-level exposure to arsenic is responsible for excess cancer cases in many parts of the U.S. Elevated county smoking prevalence strengthened the association between arsenic exposure and lung cancer incidence rate, an effect previously unseen on a population level.

  1. Study on cancer induced by long-term exposure to low dose rate radiation and its treatment

    International Nuclear Information System (INIS)

    Takahashi, Shinji

    1980-01-01

    For the purpose of discovering measures to prevent carcinogenesis by exposure to low dose radiation, radiological and clinical studies were carried out on patients with previous thorotrast injection. X-ray findings of these patients were classified into 8 types; the amount of injected thorotrast was not proportional to the size of the liver or spleen. CT could visualize sites of lymph nodes where thorotrast was remained and intrahepatic distribution of thorotrast. CT was also useful for detecting hepatic carcinoma. The amounts of thorotrast in each organ were calculated from the measurement by the whole body counter, and interstitial thorotrast was identified by fluorescent x-ray analysis. Numerical chromosome aberrations were found in all 9 patients with thorotrast; structural chromosome aberrations were found in 3 of the 9 patients. The appearance rates of small nuclei and H-J bodies in the bone marrow were higher in these patients than in controls. When patients with thorotrast had liver failure, their conditions deteriorated rapidly. Amino acid transfusion by Fisher's description was effective for hepatic encephalopathy. Out of 170 necropsied cases with thorotrast, 112 had malignant tumors of the liver with statistically significance compared to the control population. (Tsunoda, M.)

  2. Study on cancer induced by long-term exposure to low dose rate radiation and its treatment

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, S. (Hamamatsu Univ. School of Medicine, Shizuoka (Japan))

    1980-06-01

    For the purpose of discovering measures to prevent carcinogenesis by exposure to low dose radiation, radiological and clinical studies were carried out on patients with previous thorotrast injection. X-ray findings of these patients were classified into 8 types; the amount of injected thorotrast was not proportional to the size of the liver or spleen. CT could visualize sites of lymph nodes where thorotrast was remained and intrahepatic distribution of thorotrast. CT was also useful for detecting hepatic carcinoma. The amounts of thorotrast in each organ were calculated from the measurement by the whole body counter, and interstitial thorotrast was identified by fluorescent x-ray analysis. Numerical chromosome aberrations were found in all 9 patients with thorotrast; structural chromosome aberrations were found in 3 of the 9 patients. The appearance rates of small nuclei and H-J bodies in the bone marrow were higher in these patients than in controls. When patients with thorotrast had liver failure, their conditions deteriorated rapidly. Amino acid transfusion by Fisher's description was effective for hepatic encephalopathy. Out of 170 necropsied cases with thorotrast, 112 had malignant tumors of the liver with statistically significance compared to the control population.

  3. Exposure rate measurements and radiation control in post therapy with I131

    International Nuclear Information System (INIS)

    Vazquez A, M.; Castillo D, C.; Flores U, H.; Cespedes C, L.; Morgan N, C.; Sifuentes D, Y.; Marin R, K.

    2015-10-01

    During hyperthyroidism treatment, 131 I activities from 111 MBq up to 296 MBq are used. In the aim to determine if the 131 I uptake by the patient is a radiological risk to family members and public around the patient exposure rate measurements were carried out, using a limit 1.8 m R/h. Measurements were carried out in the Nuclear Medicine department of Almenara hospital in Lima, Peru. The exposure rate was measured to 0.3, 0.6, and 1.0 m from the patient from 0 to 11 days after post-administrated dose (Pda). In this study measurements were carried out in 21 hyperthyroid patients. Measurements to 1 meter, along 2-4 (16/16), 5-7 (15/15), and 8-11 (14/14) days after Pda, indicate the dose rate around 100% of patients is ≤ 1.8 m R /h. Measurements to 0.6 meters along 2-4 (16/16), 5 -7 (15/15), and 8-11 (14/14) days after Pda, indicate that the dose rate around 44% (7/16), 93% (14/15), and 100% (14/14) of patients is ≤ 1.8 m R h. On the other hand, dose rate measurements to 0.3 meters, along 2-4 (16/16), 5-7 (15/15), and 8 -11 (14/14) days after Pda, indicate that de dose rate is 13% (2/16), 6% (1/15), and 43% (6/14) of patients is ≤ 1.8 m R/h. Measured exposure rates are alike to values reported in the literature, and were used to define radiation control recommendations. (Author)

  4. Lung cancer incidence after exposure of rats to low doses of radon: influence of dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Morlier, J.P.; Morin, M.; Monchaux, G.; Fritsch, P.; Lafuma, J.; Masse, R. [CEA Centre d`Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Protection Technique; Pineau, J.F. [ALGADE, Bessines (France); Chameaud, J. [Compagnie Generale des Matieres Nucleaires (COGEMA), 87 - Razes (France)

    1994-12-31

    To study the effect on lung cancer incidence of a long exposure to low levels of radon, 500 male 3-months-old Sprague-Dawley rats, were exposed to a cumulative dose of 25 WLM of radon and its daughters, 6 hours a day, 5 days a week, during 18 months. Exposure conditions were controlled in order to maintain a defined PAEC: 42 x 10{sup 6} J.m{sup -3} (2 WL), in the range of domestic and environmental exposures. Animals were kept until they died or given euthanasia when moribund. Mean survival times were similar in both irradiated and control groups: 828 days (SD = 169) and 830 days (SD = 137), as well as lung cancer incidence, 0.60% at 25 WLM and 0.63% for controls. The incidence of lung lesions was compared statistically with controls and those previously obtained at cumulative exposures of 25 and 50 WLM delivered over a 4-6 month period, inducing a significant increase of lung cancer, 2.2% and 3.8% respectively. Such a comparison showed a decreased lung cancer incidence related to a decrease in the dose rate for low levels of radon exposure. (author).

  5. Lung cancer incidence after exposure of rats to low doses of radon: influence of dose rate

    International Nuclear Information System (INIS)

    Morlier, J.P.; Morin, M.; Monchaux, G.; Fritsch, P.; Lafuma, J.; Masse, R.; Chameaud, J.

    1994-01-01

    To study the effect on lung cancer incidence of a long exposure to low levels of radon, 500 male 3-months-old Sprague-Dawley rats, were exposed to a cumulative dose of 25 WLM of radon and its daughters, 6 hours a day, 5 days a week, during 18 months. Exposure conditions were controlled in order to maintain a defined PAEC: 42 x 10 6 J.m -3 (2 WL), in the range of domestic and environmental exposures. Animals were kept until they died or given euthanasia when moribund. Mean survival times were similar in both irradiated and control groups: 828 days (SD = 169) and 830 days (SD = 137), as well as lung cancer incidence, 0.60% at 25 WLM and 0.63% for controls. The incidence of lung lesions was compared statistically with controls and those previously obtained at cumulative exposures of 25 and 50 WLM delivered over a 4-6 month period, inducing a significant increase of lung cancer, 2.2% and 3.8% respectively. Such a comparison showed a decreased lung cancer incidence related to a decrease in the dose rate for low levels of radon exposure. (author)

  6. DETERMINATION OF HLW GLASS MELT RATE USING X-RAY COMPUTED TOMOGRAPHY

    Energy Technology Data Exchange (ETDEWEB)

    Choi, A.; Miller, D.; Immel, D.

    2011-10-06

    , a significant amount of glassy material interspersed among the gas bubbles will be excluded, thus underestimating the melt rate. Likewise, if they are drawn too high, many large voids will be counted as glass, thus overestimating the melt rate. As will be shown later in this report, there is also no guarantee that a given distribution of glass and gas bubbles along a particular sectioned plane will always be representative of the entire sample volume. Poor reproducibility seen in some LMR data may be related to these difficulties of the visual method. In addition, further improvement of the existing melt rate model requires that the overall impact of feed chemistry on melt rate be reflected on measured data at a greater quantitative resolution on a more consistent basis than the visual method can provide. An alternate method being pursued is X-ray computed tomography (CT). It involves X-ray scanning of glass samples, performing CT on the 2-D X-ray images to build 3-D volumetric data, and adaptive segmentation analysis of CT results to not only identify but quantify the distinct regions within each sample based on material density and morphologies. The main advantage of this new method is that it can determine the relative local density of the material remaining in the beaker after the heat treatment regardless of its morphological conditions by selectively excluding all the voids greater than a given volumetric pixel (voxel) size, thus eliminating much of the subjectivity involved in the visual method. As a result, the melt rate data obtained from CT scan will give quantitative descriptions not only on the fully-melted glass, but partially-melted and unmelted feed materials. Therefore, the CT data are presumed to be more reflective of the actual melt rate trends in continuously-fed melters than the visual data. In order to test the applicability of X-ray CT scan to the HLW glass melt rate study, several new series of HLW simulant/frit mixtures were melted in the

  7. Derivation of pulse height to exposure rate conversion functions for aerial radiological surveys

    International Nuclear Information System (INIS)

    Artuso, J.F.

    1985-01-01

    A method is described for deriving conversion functions that can be used to convert pulse height spectra taken at altitude to the exposure rate at the 1-m level. An integral equation is set up which involves the integration of a calculated pulse height spectrum multiplied by an unknown conversion function and then set equal to the exposure rate at ground level. This equation is then solved for the conversion function by assuming as a solution a three-term polynomial. Conversion functions have been derived for various source distributions, including surface, uniform, and exponentially distributed sources. These conversion functions are independent of source energy, which means that a conversion can be made without any knowledge of the isotopic content of the source. In the case of a uniform distribution, these conversion functions provide conversions that agree to within 10% with ground truth measurements

  8. Consequences of the exposure at low dose rates-contribution of animal experimentation

    International Nuclear Information System (INIS)

    Masse, R.

    1990-01-01

    The exposure of laboratory animals to the various types of radiations will induce cancers in relation with the tissue absorbed doses. The shape of the dose-effet relationship is most variable. It is important to distinguish which tumours are comparable to human tumours. Those showing more analogies answer but seldom to the classical lineo-quadratic relationship; however, a strong attenuation of induction is demonstrated at low dose rates. Quasi-threshold relationships are seen after the exposure of some tissues to high-LET radiations. These observations question the validity of generalizing the radiobiologists' dual action theory, setting the origin of the dose-effect relationship in the induction of events within the DNA molecule. There is an alternative in the cellular collaboration events; it assumes that the effectiveness per dose unit decreases constantly as an inverse function of the dose rate [fr

  9. Influence of random daughter exposure rate, unattachment fraction, and disequilibrium on occurrence of lung tumors

    International Nuclear Information System (INIS)

    Cross, F.T.; Palmer, R.F.; Dagle, G.E.; Busch, R.H.; Buschbom, R.L.

    1983-10-01

    Groups of male, specific-pathogen-free (SPF), Wistar rats were exposed to several concentrations of radon daughters and uranium ore dust to clarify the roles of exposure rate, unattached RaA daughters, and the degree of radon daughter disequilibrium, in the development of respiratory system disease. Modeled, human-dosimetric data indicate that the dose to sensitive tissues of the respiratory tract increases with increasing radon-daughter unattachment fraction and degree of disequilibrium. Experimental verification of these dose-effect relationships is needed to protect the health of workers and of the public exposed to radon-daughter environments. Data bearing on these relationships as well as updated results of experiments designed to test the role of radon-daughter exposure rate on lung-tumor incidence are reported. 13 references, 3 tables

  10. A high rate, low noise, x-ray silicon strip detector system

    International Nuclear Information System (INIS)

    Ludewigt, B.; Jaklevic, J.; Kipnis, I.; Rossington, C.; Spieler, H.

    1993-11-01

    An x-ray detector system, based on a silicon strip detector wire-bonded to a low noise charge-senstive amplifier integrated circuit, has been developed for synchrotron radiation experiments which require very high count rates and good energy resolution. Noise measurements and x-ray spectra were taken using a 6 mm long, 55 μm pitch strip detector in conjunction with a prototype 16-channel charge-sensitive preamplifier, both fabricated using standard 1.2 μm CMOS technology. The detector system currently achieves an energy resolution of 350 eV FWHM at 5.9 key, 2 μs peaking time, when cooled to -5 degree C

  11. Cosmic-ray production rates of neon isotopes in meteorite minerals

    International Nuclear Information System (INIS)

    Bhandari, N.

    1988-01-01

    The rates of production of 21 Ne and 22 Ne in spallation reactions, both due to solar as well as galactic cosmic rays, in some major meteoritic minerals, e.g. olivines, feldspars and pyroxenes, are calculated using their energy spectra and excitation functions. The production profiles of 21 Ne and 22 Ne due to galactic cosmic rays, and the 22 Ne/ 21 Ne ratio depend upon the size of the meteoroid. The 22 Ne/ 21 Ne ratio is very sensitive to the abundance of sodium and consequently its depth profile is distinctly different in feldspars, the ratio increasing with depth rather than decreasing as in pyroxenes and olivines. In the near-surface regions, up to a depth of 2 cm, production due to solar flare protons dominates, giving rise to a steep gradient in isotopic production as well as in the 22 Ne/ 21 Ne ratio. Composite production profiles are given and compared with measurements in some meteorites. (author). 22 refs

  12. Gamma exposure rates in the Steel Creek and Little Hell landing areas

    International Nuclear Information System (INIS)

    Marter, W.L.

    1975-01-01

    Aeroradiographic and ground transect γ surveys in the summer of 1974 were conducted to determine the degree of offsite radioactive contamination in an area immediately below the Savannah River plant boundary. Since it is recognized that mechanisms in the biosphere tend to cause nonhomogenous distribution and redistribution of radionuclides released to the environment, a plan was developed to continually evaluate the radioactivity of the offsite area. As part of this plan, a 1300-foot-long section of offsite swamp (42.9 acres) adjacent to the SRP boundary was surveyed in the latter half of October 1974 on a 10-foot grid pattern. The results of this survey show that 6.6 of the 42.9 acres surveyed in detail has γ exposure rates exceeding 57 μR/hr (approximately 500 mR/yr). The maximum exposure rate found at a single grid point was 120 μR/hr. Approximately 5.8 Ci of 137 Cs was deposited in the 42.9-acre 10-foot grid survey area. It was calculated a hypothetical person residing continuously in the location of highest exposure rate when the swamp is not flooded (77 percent of the time each year) could receive an annual dose of about 809 mR. Previous surveys of this area indicated a maximum external annual dose of 357 mR under the same residency conditions. Even with the higher exposure rates detected in the 10-foot grid survey, the more probable incremental radiation dose (above background) to hunters and fishermen who spend a few hours to a few hundred hours in this section of swamp would range from less than 1 mR to a few tens of mR per year

  13. Addressing the recovery of feeding rates in post-exposure feeding bioassays: Cyathura carinata as a case study

    Energy Technology Data Exchange (ETDEWEB)

    Pais-Costa, Antonia Juliana [IMAR—Institute of Marine Research, MARE—Marine and Environmental Sciences Centre, Faculty of Sciences and Technology, University of Coimbra, 3004-517 Coimbra (Portugal); Acevedo, Pelayo [SaBio IREC, Instituto de Investigación en Recursos Cinegéticos (UCLM-CSIC-JCCM), Ciudad Real 13005 (Spain); Marques, João Carlos [IMAR—Institute of Marine Research, MARE—Marine and Environmental Sciences Centre, Faculty of Sciences and Technology, University of Coimbra, 3004-517 Coimbra (Portugal); Martinez-Haro, Mónica, E-mail: monica.martinezharo@gmail.com [IMAR—Institute of Marine Research, MARE—Marine and Environmental Sciences Centre, Faculty of Sciences and Technology, University of Coimbra, 3004-517 Coimbra (Portugal)

    2015-02-15

    Post-exposure bioassays are used in environmental assessment as a cost-effective tool, but the effects of organism's recovery after exposure to pollutant has not yet been addressed in detail. The recoveries of post-exposure feeding rates after being exposed to two sublethal concentrations of cadmium during two different exposure periods (48 h and 96 h) were evaluated under laboratory conditions using the estuarine isopod Cyathura carinata. Results showed that feeding depression was a stable endpoint up to 24 h after cadmium exposure, which is useful for ecotoxicological bioassays. - Highlights: • We studied recovery of post-exposure feeding rates 48–96 h after cadmium exposure. • The assay is based on the isopod Cyathura carinata. • Post-exposure feeding inhibition is a stable sublethal endpoint.

  14. High count-rate study of two TES x-ray microcalorimeters with different transition temperatures

    Science.gov (United States)

    Lee, Sang-Jun; Adams, Joseph S.; Bandler, Simon R.; Betancourt-Martinez, Gabriele L.; Chervenak, James A.; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.; Porter, Frederick S.; Sadleir, John E.; Smith, Stephen J.; Wassell, Edward J.

    2017-10-01

    We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures (T c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T cs had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.3 eV at 6 keV from lower and higher T c devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the so-called event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96% throughput for 6 keV x-rays of 1025 Hz per pixel with the higher T c (faster) device, and 5.8 eV FWHM with 97% throughput with the lower T c (slower) device at 722 Hz.

  15. Exposure rate measurements on TV monitors LiF:Mg, Cu, P (GR- 200A) chips

    International Nuclear Information System (INIS)

    Sanaye, S.S.; Sadagopan, Geetha; Bhatt, B.C.

    2004-01-01

    For measuring exposure rate on black and white TV monitor screen, LiF:Mg,Cu,P (GR-200A) TLD chips were used. The samples were kept on TV monitor screen and exposed for 560 hrs with TV in 'ON' condition. The exposure rate on TV monitor screen was determined from integrated TL measurements and it varied from 0.081μGy/hr to 0.106 μGy/hr. Thus it was observed that the exposure levels were well below the prescribed limits (i.e. 5 μGy/h at 5 cm from the surface). LiF:Mg,Cu,P (GR-200A) TLD discs were also used to estimate the dose level on the surface of two types of TV monitors. The samples were kept at five different locations on the two (14 C PT AND 20 C PT) models of TV monitors and exposed for 622 hrs. From the measurement of TL, integrated dose on the screen were in the range 3.86 mR to 12.34 mR, the corresponding dose rate being 6.206 mR/hr to 19.839 mR/hr. This ensures that doses were well below the recommended limit of 0.5 mR/hr at 5cm. (author)

  16. Evidence from cosmic ray exposure (CRE) dating for the existence of a pre-Minoan caldera on Santorini, Greece

    Science.gov (United States)

    Athanassas, C. D.; Bourlès, D. L.; Braucher, R.; Druitt, T. H.; Nomikou, P.; Léanni, L.

    2016-05-01

    Cosmic ray exposure (CRE) dating was performed on the caldera cliffs of Santorini with the aim of detecting cliff segments predating the Minoan eruption (17th century BCE). The methodology involved the determination of in situ-produced cosmogenic 36Cl concentration in basaltic-to-rhyodacitic whole rocks cropping out in the cliffs. After the samples were processed following the chemical protocol of 36Cl preparation for silicate rocks, 36Cl concentrations were measured by accelerator mass spectrometry (AMS). Important challenges during the implementation procedure were related to large amounts of radiogenic 36Cl, complex modeling of inherited 36Cl, and dominance of the thermal and epithermal (low-energy) neutron capture production pathway. Nevertheless, quantitative assessments on the basis of the contribution of the low-energy neutron capture pathway percent to the total production rate validated the calculated CRE dates. Current CRE ages demonstrate that an ancient caldera existed on pre-Minoan Santorini, occupying at least the northern half of the modern-day caldera.

  17. Effective Kα x-ray excitation rates for plasma impurity measurements

    International Nuclear Information System (INIS)

    Hill, K.W.; Bitter, M.; von Goeler, S.; Hiroe, S.; Hulse, R.; Ramsey, A.T.; Sesnic, S.; Shimada, M.; Stratton, B.C.

    1986-06-01

    Metal impurity concentrations are measured by the Pulse-Height-Analyzer (PHA) diagnostic from Kα x-ray peak intensities by use of an averaged excitation rate . Low-Z impurity concentrations are inferred from the continuum enhancement (relative to a pure plasma) minus the enhancement due to metals. Since the PHA does not resolve lines from different charge states, is a weighted sum of rates; coronal equilibrium is usually assumed. The used earlier omitted the intercombination and forbidden lines from the dominant helium-like state. The result was an overestimate of metals and an underestimate of low-Z impurities in cases where metals were significant. Improved values of using recent calculations for H-, He-, and Li-like Fe range from 10 to 50% larger than the earlier rates and yield metal concentrations in better agreement with those from VUV spectroscopy

  18. Exposure to Fine Particulate Matter Leads to Rapid Heart Rate Variability Changes

    Directory of Open Access Journals (Sweden)

    Michael Riediker

    2018-01-01

    Full Text Available Introduction: Heart Rate Variability (HRV reflects the adaptability of the heart to internal and external stimuli. Reduced HRV is a predictor of post-infarction mortality. We previously found in road maintenance workers HRV-increases several hours after exposure to fine particulate matter (PM2.5. This seemed to conflict with studies where PM-exposure acutely reduced HRV. We therefore assessed whether time from exposure to HRV-assessment could explain the differences observed.Methods: On five non-consecutive days, workers carried nephelometers providing 1-min-interval PM2.5-exposure. Five-min HRV-intervals of SDNN (Standard Deviation of Normal to Normal beat intervals and pNN50 (Percentage of the interval differences exceeding 50 ms were extracted from 24-h electrocardiograms (ECGs. Following 60 min PM2.5-exposure, changes in HRV-parameters were assessed during 120-min visually and by regression analysis with control for time at work, at home, and during the night using autoregressive integrating moving average (ARIMA models to account for autocorrelation of the time-series. Additional controls included changing the time windows and including body mass index (BMI and age in the models.Result: Pattern analysis of 12,669 data points showed high modulation of mean, standard deviation (SD, and time trend of HRV (SDNN and pNN50 at low, and much reduced modulation at high PM2.5-exposures. The time trend following exposure was highly symmetrical, resembling a funnel plot. Regression analysis showed significant associations of decreasing SDNN and pNN50 (average, SD, and absolute value of time trend with increasing PM2.5-exposure, which remained significant when controlling for activity phases. Changing time windows did not change the pattern of response. Including BMI and age did not change the results.Conclusions: The reduced modulation of HRV following PM2.5-exposure is striking. It suggests strong interference with homeostatic controls. Such an

  19. Analysis of time series exposure rates obtained at a monitoring station around nuclear power stations

    International Nuclear Information System (INIS)

    Urabe, I.; Ogawa, Y.; Kimura, Y.; Honda, Y.; Nakashima, Y.; Yoshimoto, T.; Tsujimoto, T.

    1991-01-01

    From the investigation on the variation of AAD rates monitored in the natural environment around nuclear power station, it may be concluded; (1) Differences between monthly averaged air absorbed dose rates (AAD rates) given by all data obtained and those obtained in fine weather become larger in winter (from Dec. to Feb.) (2) Cummulative frequency distributions of AAD rates are very different among four seasons. Remarkably high AAD rates are observed by heavy rains in summer and snow falls or rains in winter. (3) Though the hypothesis that the frequency distribution of AAD rates fit to the lognormal distribution can not be accepted by chi-square test, higher part of the frequency distribution of AAD rates agree approximately with the lognormal one. (4) Identification of AAD rates due to plume exposure may be possible by statistical analysis assuming lognormal distribution of AAD rates as well as the discrimination method based on the reference standard using mean values and standard deviations of the data obtained in fine weather. (author)

  20. Study of the contribution of X-ray and gamma photons to the measured exposure dose

    International Nuclear Information System (INIS)

    Andriampanarivo, H.L.H.

    2000-01-01

    The aim of this work was to study the contribution of X-rays and gamma radiation to the measured dose in the city of Antananarivo. The annual indoor absorbed dose was studied as well. Measurements were carried out in twelve sites, namely public schools and churches. The mean dose rate lies between (0.34±0.03)μSv/h and (0.38±0.04)μSv/h for most of the sites. Two of them showed values between (0.40±0.04)μSv/h and (0.30±0.03)μSv/h. Mean indoor dose rate is of (0.36±0.04)μSv/h and the annual absorbed dose is (3.16±0.32)mSv/person. Indoor measurements showed mean integral values ranging from (277.22±0,22)cps to (733.66±0,37)cps. The lowest mean count rate is (277.22±0,22)cps, measured in the AMARO site, whereas the highest are (733,66±0,37)cps, (697,81±0,36)cps and (689,32±0,36)cps measured in ALO0 , AKELY, and MASINA respectively. [fr

  1. Interest Rate Demands and Television Viewing-Is a Single Exposure More Influential Than Routine Viewing?

    Science.gov (United States)

    Hetsroni, Amir; Reizer, Abira; Ben Zion, Uri

    2017-04-01

    This study examined the impact of media consumption, and particularly exposure to television, on decisions regarding interest rate demands. One hundred and fifty-four participants were randomly divided into two groups: in the manipulation group, participants were exposed to a news clip about an Iranian nuclear attack on Israel, whereas in the control group, the participants were not exposed to the film. Both groups filled a questionnaires regarding their interest rate requirements in different situations, their media conception behaviors, and demographic questionnaires. Frequent routine viewing increased the interest rate demands only among participants in the manipulation group, but the manipulation itself did not have a significant effect on interest rate demands. The results are explained in terms of cultivation theory.

  2. Exposure of patients and creation of system of quality assurance in conventional x-ray radiology in Lithuania

    International Nuclear Information System (INIS)

    Morkunas, G.; Ziliukas, J.

    1999-01-01

    One of the most important sources of exposure is medical application of ionizing radiation. X-ray examination comprise a significant part of medical exposure. Doses received by patients and quality of diagnostic images are to be optimized. Measurements of these doses were started by the Radiation Protection Centre in 1997. These measurements are performed in randomly selected x-ray departments all around Lithuania during examinations of chest and lumbar spine. Dose and parameters related to exposure and patient are registered. Quality control measurements by PMX-III are being performed on each x-ray machine used for examination. The results show that in many cases the guidance levels are of entrance surface dose for standard patient determined by the Basic Radiation Protection Standard of Lithuania are exceeded. Quality control of x-ray machines performed in 1997-1999 shows that more than 30% of these machines did not comply with the requirements though in many cases shortcomings are minor and easily removed. (au)

  3. Calculation of Buildup Factor for Gamma-ray Exposure in Two Layered Shields Made of Water and Lead

    International Nuclear Information System (INIS)

    Al-Saadi, A.H.

    2012-01-01

    The buildup factor for gamma ray exposure is most useful in calculations for biological protective shields.The buildup factors for gamma ray exposure were calculated in tow layered shields consist of water-lead and lead-water up to optical Thickness 20 mean free path (mfp) at gamma ray energies 1, 2 and 6MeV by using kalos's formula.The program has been designed to work at any atomic number of the attenuating medium, photon energy, slab thickness and and the arrangement of materials.The results obtained in this search leading to the buildup factor for gamma ray exposure at energies (1and2MeV) in lead-water were higher than the reverse case,while at energy 6 MeV the effect was opposite.The calculated data were parameterized by an empirical formula as a function of optical thickness of tow materials.The results obtained were in reasonable agreement with a previous work

  4. Monitoring catalyst flow rate in a FCC cold pilot unity by gamma ray transmission measurements

    International Nuclear Information System (INIS)

    Brito, Marcio F.P.; Netto, Wilson F.S.; Miranda, Marcia V.F.E.S.; Junior, Isacc A.S.; Dantas, Carlos C.; Melo, Silvio B.; Lima, Emerson A.O.

    2013-01-01

    A model for monitoring catalyst mass flow in riser of Fluid Catalytic Cracking - FCC, pilot unity as a function of air flow and solid injection is proposed. The fluidized FCC- catalyst bed system is investigated in an experimental setup the Cold Pilot Unity - CPU by means of gamma ray transmission measurements. Riser in CPU simulates the reactor in FCC process. By automation control air flow is instrumentally measured in riser and the solid injection is manually controlled by valve adjusting. Keeping a constant solid injection, catalyst level at the return column was measured by gamma transmission for several air flow values in riser. The operational condition reached a steady state regime before given to setup a new air flow value. A calibration of catalyst level as a function of air flow in riser is calculated, therefore, a model for solid feed rate is derived. Recent published work evaluates solid concentration in riser of the CPU by means of gamma ray transmission, and a correlation with air velocity is obtained. In this work, the model for solid feed rate was further investigated by carrying out experiments to measure catalyst concentration at the same air flow values. These experiments lead to a model for monitoring catalyst flow in riser as function of solid feed rate and air flow. Simulation with random numbers produced with Matlab software allows to define validation criteria for the model parameters. (author)

  5. Cosmic ray exposure dating of geo-morphic surface features using in situ-produced 10Be: tectonic and climatic implications

    International Nuclear Information System (INIS)

    Siame, L.; Bellier, O.; Sebrier, M.; Braucher, R.; Bourles, D.L.

    2001-01-01

    The evolution of continental landforms is mainly modulated by the impact of climatic and tectonic processes. Because of their distinctive morphology and the periodicity of their deposition, climatically induced landforms such as alluvial fans or terraces are well suited to infer rates of tectonic and continental climatic processes. Within tectonically active regions, an important step consists in dating displaced geomorphic features to calculate slip rates on active faults. Dating is probably the most critical tool because it is generally much more simpler to measure deformation resulting from tectonic activity than it is to accurately date when that deformation occurred. Recent advances in analytical chemistry and nuclear physics (accelerator mass spectrometry) now allow quantitative abundance measurements of the extremely rare isotopes produced by the interaction of cosmic rays with surface rocks and soils, the so-called in situ-produced cosmogenic nuclides ( 3 He, 10 Be, 21 Ne, 26 Al, 36 Cl), and allow to directly date the duration that a landform has been exposed to cosmic rays at the Earth's surface (Lal, 1991; Nishiizumi et al., 1993; Cerling and Craig, 1994; Clark et al., 1995]. In fact, the abundance of these cosmo-nuclides is proportional to landscape stability and, under favorable circumstances, their abundance within surface rocks can be used as a proxy for erosion rate or exposure age. These cosmo-nuclides thus provide geomorphologists with the opportunity to constrain rates of landscape evolution. This paper presents a new approach that combines cosmic ray exposure (CRE) dating using in situ-produced 10 Be and geomorphic as well as structural analyse. This approach has been applied on two active strike-slip and reverse faults located in the Andean fore-land of western Argentina. These two case studies illustrate how CRE dating using in situ-produced 10 Be is particularly well suited for geomorphic studies that aim to estimate the respective control of

  6. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, Christian, E-mail: neep@gmx.de [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Andres, Claudia; Foldyna, Borek [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Nagel, Hans Dieter [Wissenschaft and Technik für die Radiologie, Buchhholz i.d.N (Germany); Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany)

    2012-09-15

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p < 0.05) were bifocal pacemaker (61%), pacemaker dysfunction (22%), SVES (20%), ventricular salvo (20%), and atrial fibrillation (14%). Significantly (p < 0.05) prolonged scan time (>8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols.

  7. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    International Nuclear Information System (INIS)

    Luecke, Christian; Andres, Claudia; Foldyna, Borek; Nagel, Hans Dieter; Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas

    2012-01-01

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p 8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols

  8. Micronucleus formation compared to the survival rate of human melanoma cells after X-ray and neutron irradiation and hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    van Beuningen, D.; Streffer, C.; Bertholdt, G.

    1981-09-01

    After neutron and X-ray irradiation and combined X-ray irradiation and hyperthermia (3 hours, 42/sup 0/C), the survival rate of human melanoma cells was measured by means of the colony formation test and compared to the formation of micronuclei. Neutrons had a stronger effect on the formation of micronuclei than the combination of X-rays and hyperthermia. X-rays had the lowest effect. The dose effect curve showed a break at that dose level at which a reduction of cells was observed in the cultures. A good relation between survival rate and formation of micronuclei was found for the X-ray irradiation, but not for the neutron irradiation and the combined treatment. These observations are discussed. At least for X-rays, the micronucleus test has turned out to be a good screening method for the radiosensitivity of a biologic system.

  9. The background counting rates in a balloon borne hard X-ray telescope

    International Nuclear Information System (INIS)

    Dean, A.J.; Dipper, N.A.; Lewis, R.A.

    1986-01-01

    A detailed Monte Carlo model of a hard (20-300 keV) X-ray astronomical telescope has been developed in order to calculate the energy loss distribution of the unwanted background noise events in the prime detection elements. The spectral distributions of the background rates measured at balloon altitudes over Palestine, Texas are compared to the predictions of the theoretical model. Good agreement has been found in terms of both the overall intensity level as well as the spectral distribution. (orig.)

  10. Cosmic ray production rates of Be-10 and Al-26 in quartz from glacially polished rocks

    Science.gov (United States)

    Nishiizumi, K.; Kohl, C. P.; Winterer, E. L.; Klein, J.; Middleton, R.

    1989-01-01

    The concentrations of Be-10 and Al-26 in quartz crystals extracted from glacially polished granitic surfaces from the Sierra Nevada range are studied. These surfaces are identified with the glacial advance during the Tioga period about 11,000 yr ago. The measurements yield the most accurate estimates to date for the absolute production rates of three nuclides in SiO2 due to cosmic ray nucleons and muons for geomagnetic latitudes 43.8-44.6 N and altitudes 2.1-3.6 km.

  11. Strategy of image-information-guided dose rate adjustment in digital X-ray television

    International Nuclear Information System (INIS)

    Sliva, K.

    1992-01-01

    The experiments were so designed and carried out that it was even possible for extremely overexposed or underexposed displays to be ascertained within the framework of this study. They were based on observations in phantoms suitable to simulate situations encountered in actual practice. These permitted variations in patient volume (using different water volumes) just as well as the creation of any desired organ constellation (by insertion of bone material, etc.). It is one requirement of this experimental procedure that the X-ray unit used can be operated without automatic dose rate adjustment. A computer equipped with Frame-Grabber card may serve as an image memory. (orig.) [de

  12. Evaluation of absorbed radiation dose rate in a didactic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Phelipe Amaral Ferreira; Perini, Ana Paula; Neves, Lucio Pereira

    2016-01-01

    This work was performed in order to create a new didactic experiment in the X-ray apparatus of PHYWE, where the saturation current was obtained through a free air ionization chamber. The values of saturation currents were obtained in two ways. Initially, the anodic DDP was kept constant and the anodic current was varied. In the second way, the anodic current was kept constant while the anodic DDP was varied. Therefore, we were able to evaluate the dependence of the absolved dose rate in relation to the DDP and the tube current. (author)

  13. Approximate techniques for calculating gamma ray dose rates in nuclear power plants

    International Nuclear Information System (INIS)

    Lahti, G.P.

    1986-01-01

    Although today's computers have made three-dimensional discrete ordinates transport codes a virtual reality, there is still a need for approximate techniques for estimating radiation environments. This paper discusses techniques for calculating gamma ray dose rates in nuclear power plants where Compton scattering is the dominant attenuation mechanism. The buildup factor method is reviewed; its use and misuse are discussed. Several useful rules-of-thumb are developed. The paper emphasizes the need for understanding the fundamental physics and draws heavily on the old, classic references

  14. Spatial variation of natural terrestrial gamma-ray dose rates in Brunei

    International Nuclear Information System (INIS)

    Hu, S.J.; Lai, K.K.; Manato, S.; Kodaira, K.

    1998-01-01

    A carbon survey of natural terrestrial gamma-rat dose rates along the main roads of the western part of Brunei Darussalam was carried out using two portable type 1.5 φ x 4 NaI(TI) and 1 φ x 2 NaI(TI) scintillation counters. A series of semicontinuous count rates measurements were performed inside a moving vehicle. This yielded equal-distance data which were analysed statistically to obtain the spatial variation of the natural terrestrial gamma-ray dose rates. The equal-distance data of dose rates were obtained by correcting for shielding effect of the car. The thickness of the pavement and the contribution from the pavement material were estimated from a correlation curve between the dose rates measured on pavements and on the nearby soils. A spectral analysis of the equal-distance data enabled us to clarify the structure of the spatial variation in dose rates. The data could be reasonably smoothened by removing the random noise components in a higher wave number region. (author). 6 refs., 7 figs., 1 tab

  15. Binary neutron star merger rate via the luminosity function of short gamma-ray bursts

    Science.gov (United States)

    Paul, Debdutta

    2018-04-01

    The luminosity function of short Gamma Ray Bursts (GRBs) is modelled by using the available catalogue data of all short GRBs (sGRBs) detected till October, 2017. The luminosities are estimated via the `pseudo-redshifts' obtained from the `Yonetoku correlation', assuming a standard delay distribution between the cosmic star formation rate and the production rate of their progenitors. While the simple powerlaw is ruled out to high confidence, the data is fit well both by exponential cutoff powerlaw and broken powerlaw models. Using the derived parameters of these models along with conservative values in the jet opening angles seen from afterglow observations, the true rate of short GRBs are derived. Assuming a short GRB is produced from each binary neutron star merger (BNSM), the rate of gravitational wave (GW) detections from these mergers are derived for the past, present and future configurations of the GW detector networks. Stringent lower limits of 1.87yr-1 for the aLIGO-VIRGO, and 3.11yr-1 for the upcoming aLIGO-VIRGO-KAGRA-LIGO/India configurations are thus derived for the BNSM rate at 68% confidence. The BNSM rates calculated from this work and that independently inferred from the observation of the only confirmed BNSM observed till date, are shown to have a mild tension; however the scenario that all BNSMs produce sGRBs cannot be ruled out.

  16. Suicide Rates and State Laws Regulating Access and Exposure to Handguns.

    Science.gov (United States)

    Anestis, Michael D; Anestis, Joye C

    2015-10-01

    Using previous research, we examined the impact of 4 handgun laws (waiting periods, universal background checks, gun locks, and open carrying regulations) on suicide rates. We used publicly available databases to collect information on statewide laws, suicide rates, and demographic characteristics for 2013. Each law was associated with significantly lower firearm suicide rates and the proportion of suicides resulting from firearms. In addition, each law, except for that which required a waiting period, was associated with a lower overall suicide rate. Follow-up analyses showed a significant indirect effect on overall suicide rates through the proportion of suicides by firearms, indicating that the reduced overall suicide rate was attributable to fewer suicide attempts, fewer handguns in the home, suicide attempts using less lethal means, or a combination of these factors. States that implemented any of these laws saw a decreased suicide rate in subsequent years, whereas the only state that repealed 1 of these laws saw an increased suicide rate. Our results were supportive of a potentially vital role in suicide prevention for state legislation that limits access and exposure to handguns.

  17. Exposure to Discrimination and Heart Rate Variability Reactivity to Acute Stress among Women with Diabetes.

    Science.gov (United States)

    Wagner, Julie; Lampert, Rachel; Tennen, Howard; Feinn, Richard

    2015-08-01

    Exposure to racial discrimination has been linked to physiological reactivity. This study investigated self-reported exposure to racial discrimination and parasympathetic [high-frequency heart rate variability (HF-HRV)] and sympathetic (norepinephrine and cortisol) activity at baseline and then again after acute laboratory stress. Lifetime exposure to racial discrimination was measured with the Schedule of Racist Events scale. Thirty-two women (16 Black and 16 White) with type 2 diabetes performed a public speaking stressor. Beat-to-beat intervals were recorded on electrocardiograph recorders, and HF-HRV was calculated using spectral analysis and natural log transformed. Norepinephrine and cortisol were measured in blood. Higher discrimination predicted lower stressor HF-HRV, even after controlling for baseline HF-HRV. When race, age, A1c and baseline systolic blood pressure were also controlled, racial discrimination remained a significant independent predictor of stressor HF-HRV. There was no association between lifetime discrimination and sympathetic markers. In conclusion, preliminary data suggest that among women with type 2 diabetes mellitus (T2DM), exposure to racial discrimination is adversely associated with parasympathetic, but not sympathetic, reactivity. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Does chronic occupational exposure to volatile anesthetic agents influence the rate of neutrophil apoptosis?

    LENUS (Irish Health Repository)

    Goto, Y

    2012-02-03

    PURPOSE: The purpose of this preliminary investigation was to determine whether the rate of neutrophil apoptosis in health care workers is influenced by exposure to volatile anesthetic agents. METHODS: Percentage neutrophil apoptosis (Annexin-V FITC assay) was measured in health care workers (n = 20) and unexposed volunteers (n = 10). For the health care workers, time weighted personal exposure monitoring to N2O, sevoflurane and isoflurane was carried out. RESULTS: The sevoflurane and isoflurane concentrations to which health care workers were exposed were less than recommended levels in all 20 cases. Percent apoptosis was less at 24 (but not at one and 12) hr culture in health care workers [50.5 (9.7)%; P = 0.008] than in unexposed volunteers [57.3 (5.1)%]. CONCLUSION: Inhibition of neutrophil apoptosis at 24 hr culture was demonstrated in health care workers chronically exposed to volatile anesthetic agents. Exposure was well below recommended levels in the both scavenged and unscavenged work areas in which the study was carried out. Further study is required to assess the effect of greater degrees of chronic exposure to volatile anesthetic agents on neutrophil apoptosis.

  19. A soft X-ray source based on a low divergence, high repetition rate ultraviolet laser

    Science.gov (United States)

    Crawford, E. A.; Hoffman, A. L.; Milroy, R. D.; Quimby, D. C.; Albrecht, G. F.

    The CORK code is utilized to evaluate the applicability of low divergence ultraviolet lasers for efficient production of soft X-rays. The use of the axial hydrodynamic code wih one ozone radial expansion to estimate radial motion and laser energy is examined. The calculation of ionization levels of the plasma and radiation rates by employing the atomic physics and radiation model included in the CORK code is described. Computations using the hydrodynamic code to determine the effect of laser intensity, spot size, and wavelength on plasma electron temperature are provided. The X-ray conversion efficiencies of the lasers are analyzed. It is observed that for a 1 GW laser power the X-ray conversion efficiency is a function of spot size, only weakly dependent on pulse length for time scales exceeding 100 psec, and better conversion efficiencies are obtained at shorter wavelengths. It is concluded that these small lasers focused to 30 micron spot sizes and 10 to the 14th W/sq cm intensities are useful sources of 1-2 keV radiation.

  20. Direct electron acceleration in plasma waveguides for compact high-repetition-rate x-ray sources

    International Nuclear Information System (INIS)

    Lin, M-W; Jovanovic, I

    2014-01-01

    Numerous applications in fundamental and applied research, security, and industry require robust, compact sources of x-rays, with a particular recent interest in monochromatic, spatially coherent, and ultrafast x-ray pulses in well-collimated beams. Such x-ray sources usually require production of high-quality electron beams from compact accelerators. Guiding a radially polarized laser pulse in a plasma waveguide has been proposed for realizing direct laser acceleration (DLA), where the electrons are accelerated by the axial electric field of a co-propagating laser pulse (Serafim et al 2000 IEEE Trans. Plasma Sci. 28 1190). A moderate laser peak power is required for DLA when compared to laser wakefield acceleration, thus offering the prospect for high repetition rate operation. By using a density-modulated plasma waveguide for DLA, the acceleration distance can be extended with pulse guiding, while the density-modulation with proper axial structure can realize the quasi-phase matching between the laser pulses and electrons for a net gain accumulation (York et al 2008 Phys. Rev. Lett. 100 195001; York et al 2008 J. Opt. Soc. Am. B 25 B137; Palastro et al 2008 Phys. Rev. E 77 036405). We describe the development and application of a test particle model and particle-in-cell model for DLA. Experimental setups designed for fabrication of optically tailored plasma waveguides via the ignitor-heater scheme, and for generation and characterization of radially polarized short pulses used to drive DLA, are presented. (paper)

  1. Large area, low capacitance Si(Li) detectors for high rate x-ray applications

    International Nuclear Information System (INIS)

    Rossington, C.S.; Fine, P.M.; Madden, N.W.

    1992-10-01

    Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication procedures, I-V and C-V characteristics, noise performance, and spectral response to 2-60 keV x-rays are described

  2. X-RAY DETERMINATION OF THE VARIABLE RATE OF MASS ACCRETION ONTO TW HYDRAE

    Energy Technology Data Exchange (ETDEWEB)

    Brickhouse, N. S.; Cranmer, S. R.; Dupree, A. K.; Guenther, H. M.; Wolk, S. J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Luna, G. J. M. [Current address: Instituto de Astronomia y Fisica del Espacio (IAFE), Buenos Aires (Argentina)

    2012-12-01

    Diagnostics of electron temperature (T{sub e} ), electron density (n{sub e} ), and hydrogen column density (N{sub H}) from the Chandra High Energy Transmission Grating spectrum of He-like Ne IX in TW Hydrae (TW Hya), in conjunction with a classical accretion model, allow us to infer the accretion rate onto the star directly from measurements of the accreting material. The new method introduces the use of the absorption of Ne IX lines as a measure of the column density of the intervening, accreting material. On average, the derived mass accretion rate for TW Hya is 1.5 Multiplication-Sign 10{sup -9} M{sub Sun} yr{sup -1}, for a stellar magnetic field strength of 600 G and a filling factor of 3.5%. Three individual Chandra exposures show statistically significant differences in the Ne IX line ratios, indicating changes in N{sub H}, T{sub e} , and n{sub e} by factors of 0.28, 1.6, and 1.3, respectively. In exposures separated by 2.7 days, the observations reported here suggest a five-fold reduction in the accretion rate. This powerful new technique promises to substantially improve our understanding of the accretion process in young stars.

  3. Determination of existing exposure level of population during X ray investigations

    International Nuclear Information System (INIS)

    Tselinov, N.V.; Kudritskij, Yu.K.

    1978-01-01

    The distribution of X ray procedures among 500 inhabitants of the city of Vorkuta in 1975 is studied. Data on the distribution of the subjects by age group and type of X ray procedure are presented. The results obtained broaden the existing concepts on hygienic importance of radiation received by the population of the country during X ray studies. It is proposed that these results be used in developing methods for standardizing X ray procedures

  4. Radiological protection in X-ray diagnosis: How to minimize the patient exposure in X-ray diagnosis

    International Nuclear Information System (INIS)

    Araujo, A.M.C. de.

    1986-01-01

    The principles involved in the radiation protection and the radiographic process are discussed. An adequate systematic work is presented, to achieve the main goal of the Radiation Protection that is, to irradiate the patient and the staff with lowest possible exposure. (M.A.C.) [pt

  5. Exposure testing of fasteners in preservative treated wood: Gravimetric corrosion rates and corrosion product analyses

    Energy Technology Data Exchange (ETDEWEB)

    Zelinka, Samuel L., E-mail: szelinka@fs.fed.u [USDA Forest Products Laboratory, One Gifford Pinchot Drive, Madison, WI 53726 (United States); Sichel, Rebecca J. [College of Engineering, University of Wisconsin, Madison, WI 53706 (United States); Stone, Donald S. [Department of Materials Science and Engineering, College of Engineering, University of Wisconsin, Madison, WI 53706 (United States)

    2010-12-15

    Research highlights: {yields} The composition of the corrosion products was similar for the nail head and shank. {yields} Reduced copper was not detected on any of the fasteners. {yields} Measured corrosion rates were between 1 and 35 {mu}m year{sup -1}. - Abstract: Research was conducted to determine the corrosion rates of metals in preservative treated wood and also understand the mechanism of metal corrosion in treated wood. Steel and hot-dip galvanized steel fasteners were embedded in wood treated with one of six preservative treatments and exposed to 27 {sup o}C at 100% relative humidity for 1 year. The corrosion rate was determined gravimetrically and the corrosion products were analyzed with scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. Although the accepted mechanism of corrosion in treated wood involves the reduction of cupric ions from the wood preservative, no reduced copper was found on the corrosion surfaces. The galvanized corrosion products contained sulfates, whereas the steel corrosion products consisted of iron oxides and hydroxides. The possible implications and limitations of this research on fasteners used in building applications are discussed.

  6. X-ray exposure dose for the gonadal gland by the examination of computerized tomography and its protection

    International Nuclear Information System (INIS)

    Moriuchi, Iwao; Kaiya, Hisanori; Hirata, Toshifumi; Asada, Shuichi

    1978-01-01

    Computerized tomography (CT) is very useful for neuroradiological examination, and so it may possibly be used for screening tests. But x-ray exposure dose by a examination of CT is considerable, especially for the male gonadal gland. This study showed that the dose from a complete CT examination of 10 - 15 scans for a male gonadal gland was about 1,800 times more than a single plain neuroradiography. But by only a 0.07 mm lead equivalent protecter, the exposure dose resulting from CT for a gonadal gland could be reduced to 0.0 mrad. (auth.)

  7. Dose-rate models for human survival after exposure to ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Jones, T.D.; Morris, M.D.; Young, R.W.

    1986-01-01

    This paper reviews new estimates of the L/sub 50/ in man by Mole and by Rotblat, the biological processes contributing to hematologic death, the collection of animal experiments dealing with hematologic death, and the use of regression analysis to make new estimates of human mortality based on all relevant animal studies. Regression analysis of animal mortality data has shown that mortality is dependent strongly on dose rate, species, body weight, and time interval over which the exposure is delivered. The model has predicted human LD/sub 50/s of 194, 250, 310, and 360 rad to marrow when the exposure time is a minute, an hour, a day, and a week, respectively.

  8. A survey in Portuguese X-ray fluoroscopy equipment: dose rates and image quality

    International Nuclear Information System (INIS)

    Teixeira, Nuno G.; Cunha, Gilda R.; Coutinho, Guilherme M.; Trindade, Hugo R.; Carvoeiras, Pedro P.

    2015-01-01

    X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level. (authors)

  9. External dose rates from gamma rays and activity concentrations in foodstuffs and herbage in eastern Europe

    International Nuclear Information System (INIS)

    Wilkins, B.T.; Dodd, N.J.; Bradley, E.J.

    1986-01-01

    The initial scarcity of reliable information in eastern European countries, coupled with the proximity of the Chernobyl installation, resulted in understandable concern among British nationals living in these areas or visiting them on a short-term basis. Accordingly, arrangements were made by the Foreign and Commonwealth Office (FCO) for the appropriate Embassies to send samples of milk, drinking water, grass and available fruit and vegetables to the Board's laboratories at Chilton for analysis. In addition, simple monitoring equipment was supplied to the Embassies for measurements of external dose rates from gamma rays out of doors. The first set of samples was collected in Moscow on May 3rd 1986. Most consignments arrived at Chilton within 24 hours of collection. Speed was important, not only because of the need for information but because vegetation needed to be sufficiently fresh to permit meaningful measurement. By the end of June 1986, the results of systematic monitoring programmes in eastern Europe were being disseminated more freely, so that frequent sampling by the Embassies was no longer considered necessary. Since that time samples have been received only occasionally from those Embassies where concern still persists. This report summarises the results of measurements and samples taken by June 30th 1986. Data for γ-ray emitting radionuclides in foodstuffs were issued to the FCO in a series of Measurement Reports. Here they are presented together with data for actinide element concentrations in a limited number of samples. Measurements of outdoor external dose rates made by the Embassies are also included

  10. Measurement of exposure buildup factors: The influence of scattered photons on gamma-ray attenuation coefficients

    Science.gov (United States)

    Mann, Kulwinder Singh

    2018-01-01

    Scattered photon's influence on measured values of attenuation coefficients (μm, cm2g-1) for six low-Z (effective atomic number) building materials, at three photon energies has been estimated. Narrow-beam transmission geometry has been used for the measurements. Samples of commonly used engineering materials (Cements, Clay, Lime-Stone, Plaster of Paris) have been selected for the present study. Standard radioactive sources Cs137 and Co60 have been used for obtaining γ-ray energies 661.66, 1173.24 and 1332.50 keV. The optical thickness (OT) of 0.5 mfp (mean free path) has been found the optimum optical thickness (OOT) for μm-measurement in the selected energy range (661.66-1332.50 keV). The aim of this investigation is to provide neglected information regarding subsistence of scattered photons in narrow beam geometry measurements for low-Z materials. The measurements have been performed for a wide range of sample-thickness (2-26 cm) such that their OT varies between 0.2-3.5 mfp in selected energy range. A computer program (GRIC2-toolkit) has been used for various theoretical computations required in this investigation. It has been concluded that in selected energy-range, good accuracy in μm-measurement of low-Z materials can be achieved by keeping their sample's OT below 0.5 mfp. The exposure buildup factors have been measured with the help of mathematical-model developed in this investigation.

  11. Risk of mammary oncogenesis from exposure to neutrons or gamma rays: experimental methodology and early findings

    International Nuclear Information System (INIS)

    Clifton, K.H.; Sridharan, B.N.; Gould, M.N.

    1976-01-01

    A project has been initiated to define the risk of oncogenesis per rad of high or low linear energy transfer (LET) radiation per surviving mammary cell and its modification by hormones. This work was undertaken because: (a) mammary carcinoma is the principle neoplastic disease of American women; (b) rats have been demonstrated to be remarkably susceptible to mammary oncogenesis following neutron irradiation; (c) rats are similar to women in the importance of hormones to carcinoma induction and progression in their mammary glands; and (d) exposure to neutrons is likely to increase with increasing use of nuclear reactors and development of neutron radiotherapy sources. To measure mammary cell survival and, ultimately, postirradiation repair capacity, the authors are developing an in-vivo end-point dilution assay based on the formation of glandular structures after the transplantation of known numbers of monodispersed rat mammary epithelial cell suspensions. Such grafts initially give rise to alveolus-like spheres and, with time, to complete glands. Growth and secretion can be stimulated in them by hormonal manipulation. In the short-term assays and the longer-term carcinogenesis studies, elevated endogenous mammotropic hormone, prolactin (MtH) levels have been induced by grafting of anterior pituitary tissue or of MtT (MtH-secreting pituitary tumours). Steroid hormone levels have been manipulated by surgical ablation or injection. Irradiations have been performed with a modified neutron fission spectrum generated by a Triga reactor, or with 137 Cs γ rays. Results with two inbred rat strains indicate: (a) that the type (carcinoma or fibroadenoma), incidence and latency of mammary tumours is markedly influenced by the circulating levels of MtH: and (b) that adrenal deficiency markedly enhances the induction of mammary carcinomas in irradiated rats with high endogenous MtH levels. Further studies are in progress. (author)

  12. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    International Nuclear Information System (INIS)

    Veinot, K.G.; Dewji, S.A.; Hiller, M.M.; Eckerman, K.F.; Easterly, C.E.

    2017-01-01

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133. (orig.)

  13. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K.G. [Easterly Scientific, Knoxville, TN (United States); Y-12 National Security Complex, Oak Ridge, TN (United States); Dewji, S.A.; Hiller, M.M. [Center for Radiation Protection Knowledge, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Eckerman, K.F.; Easterly, C.E. [Easterly Scientific, Knoxville, TN (United States)

    2017-11-15

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133. (orig.)

  14. MODERN PECULIARITIES OF THE MEDICAL EXPOSURE LEVELS FORMING OF THE TATARSTAN REPUBLIC POPULATION DURING X-RAY PROCEDURES IMPLEMENTATION

    Directory of Open Access Journals (Sweden)

    S. A. Ryzhkin

    2015-01-01

    Full Text Available The purpose. The purpose of the investigation is an assessment of the peculiarities of forming and registration of the collective doses of patients and the population of the Tatarsatan Republic (RT from medical exposure and the development of measures for optimization of this radiation factor.Materials and methods. The analysis is based on the forms of the Federal statistical observation № 3-DOZ «Data on the exposure doses to patients obtained during medical radiological examination» (form № 3-DOZ and radiation-hygienic passports of RT for the period from 2006 to 2013.The results. Annually in RT there is an increase of the number of performed X-ray procedures, which reached the value of 6279696 (1.64 procedures per resident per year in 2013. During the reporting period (from 2006 to 2013 the structure of the performed X-ray procedures has also changed. It is observed that the percentage of fluorography procedures in the overall structure decreased from 41.3% to 31.3% at the same time the level of absolute value of annually performed fluorography procedures is stable. There is an increase in the absolute number of radiographic procedures performed during the period from 2578754 to 4072810 X-rays per year, that is 1.58 times higher. Absolute and relative values related to X-ray fluoroscopy examinations decreased from 1.1% to 0.7%. In contrast, the absolute number of annually performed X-ray computed tomography examinations (CT has increased over the period by 3.3 times and percentage of CT in overall structure of X-ray procedure is 2.7%. The number of special investigations has increased in 2.1 times, but the relative value remained at average level of 0.4% on general background of the increasing of X-ray activity in the region. This fact influenced the change in the radiation-hygienic indexes of medical radiation exposure of the population of RT. According to №3-DOZ forms and radiation-hygienic passports of the

  15. Upper arm elevation and repetitive shoulder movements: a general population job exposure matrix based on expert ratings and technical measurements.

    Science.gov (United States)

    Dalbøge, Annett; Hansson, Gert-Åke; Frost, Poul; Andersen, Johan Hviid; Heilskov-Hansen, Thomas; Svendsen, Susanne Wulff

    2016-08-01

    We recently constructed a general population job exposure matrix (JEM), The Shoulder JEM, based on expert ratings. The overall aim of this study was to convert expert-rated job exposures for upper arm elevation and repetitive shoulder movements to measurement scales. The Shoulder JEM covers all Danish occupational titles, divided into 172 job groups. For 36 of these job groups, we obtained technical measurements (inclinometry) of upper arm elevation and repetitive shoulder movements. To validate the expert-rated job exposures against the measured job exposures, we used Spearman rank correlations and the explained variance[Formula: see text] according to linear regression analyses (36 job groups). We used the linear regression equations to convert the expert-rated job exposures for all 172 job groups into predicted measured job exposures. Bland-Altman analyses were used to assess the agreement between the predicted and measured job exposures. The Spearman rank correlations were 0.63 for upper arm elevation and 0.64 for repetitive shoulder movements. The expert-rated job exposures explained 64% and 41% of the variance of the measured job exposures, respectively. The corresponding calibration equations were y=0.5%time+0.16×expert rating and y=27°/s+0.47×expert rating. The mean differences between predicted and measured job exposures were zero due to calibration; the 95% limits of agreement were ±2.9% time for upper arm elevation >90° and ±33°/s for repetitive shoulder movements. The updated Shoulder JEM can be used to present exposure-response relationships on measurement scales. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Effects of chronic occupational exposure to anaesthetic gases on the rate of neutrophil apoptosis among anaesthetists.

    LENUS (Irish Health Repository)

    Tyther, R

    2012-02-03

    BACKGROUND AND OBJECTIVE: Volatile anaesthetic agents are known to influence neutrophil function. The aim was to determine the effect of chronic occupational exposure to volatile anaesthetic agents on the rate of neutrophil apoptosis among anaesthetists. To test this hypothesis, we compared the rate of neutrophil apoptosis in anaesthetists who had been chronically exposed to volatile anaesthetic agents with that in unexposed volunteers. METHODS: Venous blood (20 mL) was withdrawn from 24 ASA I-II volunteers, from which neutrophils were isolated, and maintained in culture. At 1, 12 and 24 h in culture, the percentage of neutrophil apoptosis was assessed by dual staining with annexin V-FITC and propidium iodide. RESULTS: At 1 h (but not at 12 and 24 h) in culture, the rate of neutrophil apoptosis was significantly less in the anaesthetists--13.8 (12.9%) versus 34.4 (12.1%) (P = 0.001). CONCLUSIONS: Chronic occupational exposure to volatile anaesthetic agents may inhibit neutrophil apoptosis. This may have implications for anaesthetists and similarly exposed healthcare workers in terms of the adequacy of their inflammatory response.

  17. X-ray exposures given with various combinations of film and screen

    International Nuclear Information System (INIS)

    Schlenker, R.A.; Kirsh, I.E.

    A comparison of entrance exposure doses of patients for various film and screen combinations and xeroradiographs showed that moderate speed screen and film gave exposures 4 to 7 times greater than fast film and screen and that xeroradiographs produced exposures 20 to 40 times greater than fast film and screen. Xeroradiographs produced table top incident exposures which exceeded Illinois Department of Health limits, while conventional film-screen combinations did not. (U.S.)

  18. A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Burion, Steve; Funk, Tobias; Speidel, Michael A.

    2013-01-01

    Purpose: Reduction of radiation dose in x-ray imaging has been recognized as a high priority in the medical community. Here the authors show that a regional adaptive exposure method can reduce dose-area product (DAP) in x-ray fluoroscopy. The authors' method is particularly geared toward providing dose savings for the pediatric population. Methods: The scanning beam digital x-ray system uses a large-area x-ray source with 8000 focal spots in combination with a small photon-counting detector. An imaging frame is obtained by acquiring and reconstructing up to 8000 detector images, each viewing only a small portion of the patient. Regional adaptive exposure was implemented by varying the exposure of the detector images depending on the local opacity of the object. A family of phantoms ranging in size from infant to obese adult was imaged in anteroposterior view with and without adaptive exposure. The DAP delivered to each phantom was measured in each case, and noise performance was compared by generating noise arrays to represent regional noise in the images. These noise arrays were generated by dividing the image into regions of about 6 mm 2 , calculating the relative noise in each region, and placing the relative noise value of each region in a one-dimensional array (noise array) sorted from highest to lowest. Dose-area product savings were calculated as the difference between the ratio of DAP with adaptive exposure to DAP without adaptive exposure. The authors modified this value by a correction factor that matches the noise arrays where relative noise is the highest to report a final dose-area product savings. Results: The average dose-area product saving across the phantom family was (42 ± 8)% with the highest dose-area product saving in the child-sized phantom (50%) and the lowest in the phantom mimicking an obese adult (23%). Conclusions: Phantom measurements indicate that a regional adaptive exposure method can produce large DAP savings without compromising

  19. Set of programs for determining exposure and dose rates from selected sources of gamma radiation

    International Nuclear Information System (INIS)

    Hep, J.; Kralovcova, E.; Smutny, V.; Valenta, V.

    1982-01-01

    The programs are described for the determination of exposure and dose rate of gamma radiation from point, surface, linear and volume sources with and without shielding. The computation is conducted using the classical method taking into consideration the buildup factor. For the computation of the buildup factor in heterogeneous shielding the Broder and Kitazuma formulas are used. Kitazuma's alpha coefficients were calculated recurrently using a new semi-empirical method. Taylor's approximation was used for the calculation of the buildup factor in a single layer

  20. Degradation and annealing studies on gamma rays irradiated COTS PPD CISs at different dose rates

    International Nuclear Information System (INIS)

    Wang, Zujun; Ma, Yingwu; Liu, Jing; Xue, Yuan; He, Baoping; Yao, Zhibin; Huang, Shaoyan; Liu, Minbo; Sheng, Jiangkun

    2016-01-01

    The degradation and annealing studies on Colbalt-60 gamma-rays irradiated commercial-off-the-shelf (COTS) pinned photodiode (PPD) CMOS image sensors (CISs) at the various dose rates are presented. The irradiation experiments of COTS PPD CISs are carried out at 0.3, 3.0 and 30.0 rad(Si)/s. The COTS PPD CISs are manufactured using a standard 0.18-μm CMOS technology with four-transistor pixel PPD architecture. The behavior of the tested CISs shows a remarkable degradation after irradiation and differs in the dose rates. The dark current, dark signal non-uniformity (DSNU), random noise, saturation output, signal to noise ratio (SNR), and dynamic range (DR) versus the total ionizing dose (TID) at the various dose rates are investigated. The tendency of dark current, DSNU, and random noise increase and saturation output, SNR, and DR to decrease at 3.0 rad(Si)/s are far greater than those at 0.3 and 30.0 rad(Si)/s. The damage mechanisms caused by TID irradiation at the various dose rates are also analyzed. The annealing tests are carried out at room temperature with unbiased conditions after irradiation.

  1. Degradation and annealing studies on gamma rays irradiated COTS PPD CISs at different dose rates

    Science.gov (United States)

    Wang, Zujun; Ma, Yingwu; Liu, Jing; Xue, Yuan; He, Baoping; Yao, Zhibin; Huang, Shaoyan; Liu, Minbo; Sheng, Jiangkun

    2016-06-01

    The degradation and annealing studies on Colbalt-60 gamma-rays irradiated commercial-off-the-shelf (COTS) pinned photodiode (PPD) CMOS image sensors (CISs) at the various dose rates are presented. The irradiation experiments of COTS PPD CISs are carried out at 0.3, 3.0 and 30.0 rad(Si)/s. The COTS PPD CISs are manufactured using a standard 0.18-μm CMOS technology with four-transistor pixel PPD architecture. The behavior of the tested CISs shows a remarkable degradation after irradiation and differs in the dose rates. The dark current, dark signal non-uniformity (DSNU), random noise, saturation output, signal to noise ratio (SNR), and dynamic range (DR) versus the total ionizing dose (TID) at the various dose rates are investigated. The tendency of dark current, DSNU, and random noise increase and saturation output, SNR, and DR to decrease at 3.0 rad(Si)/s are far greater than those at 0.3 and 30.0 rad(Si)/s. The damage mechanisms caused by TID irradiation at the various dose rates are also analyzed. The annealing tests are carried out at room temperature with unbiased conditions after irradiation.

  2. Development of a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value

    International Nuclear Information System (INIS)

    Kueppers, C.; Sering, M.; Poppe, B.; Poplawski, A.; Looe, H.K.; Beyer, D.; Pfaffenberger, A.; Chofor, N.; Eenboom, F.

    2012-01-01

    The research project on the development a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value includes the following issues: Fundamental facts: dental X-ray examination techniques, dose relevant factors and characteristics during X-ray examinations, radiation exposed organs during dental X-ray examinations, dose assessment based on phantoms. Materials and methodologies of the project: TLD measurements using the phantom, calculation of the effective dose during dental X-ray examinations, properties and settings of the reference facilities for the determination of radiation exposure, selection of dental offices, dosimetric measurements, data acquisition and statistical evaluation. Results of dosimetric examinations: results of dosimetric measurements at reference facilities, results of dosimetric measurements in dental offices. Discussion of the concept for the determination of the radiation exposure during dental X-ray examinations.

  3. Solar proton exposure of an ICRU sphere within a complex structure part II: Ray-trace geometry.

    Science.gov (United States)

    Slaba, Tony C; Wilson, John W; Badavi, Francis F; Reddell, Brandon D; Bahadori, Amir A

    2016-06-01

    A computationally efficient 3DHZETRN code with enhanced neutron and light ion (Z ≤ 2) propagation was recently developed for complex, inhomogeneous shield geometry described by combinatorial objects. Comparisons were made between 3DHZETRN results and Monte Carlo (MC) simulations at locations within the combinatorial geometry, and it was shown that 3DHZETRN agrees with the MC codes to the extent they agree with each other. In the present report, the 3DHZETRN code is extended to enable analysis in ray-trace geometry. This latest extension enables the code to be used within current engineering design practices utilizing fully detailed vehicle and habitat geometries. Through convergence testing, it is shown that fidelity in an actual shield geometry can be maintained in the discrete ray-trace description by systematically increasing the number of discrete rays used. It is also shown that this fidelity is carried into transport procedures and resulting exposure quantities without sacrificing computational efficiency. Published by Elsevier Ltd.

  4. Gamma exposure rate reduction and residual radium-226 concentrations resulting from decontamination activities conducted at the former uranium millsite in Shiprock, New Mexico

    International Nuclear Information System (INIS)

    Hans, J.M. Jr.; Hurst, T.L.

    1981-01-01

    Gamma radiation surveys and residual radium 226 soil samples were taken as part of the decontamination activities of the former Shiprock uranium mill site in New Mexico. In order to facilitate the decontamination activities, the mill site and its contaminated environs were divided into 6 major areas. Extensive data are presented in 2 appendices of the pre- and post-decontamination gamma ray exposure rates made on mill site, and of radium 226 concentrations in surface soil samples. A training program established on the mill site by the Navajo Engineering and Construction Authority is described

  5. Determination of correction and conversion factor of exposure rate generated Gamma spectrometer GR-320 to Victoreen data

    International Nuclear Information System (INIS)

    Supardjo-AS; Mappa, Djody-Rachim; Nasrun-Syamsul; Syamsul-Hadi

    2000-01-01

    Exposure rate data of Muria Peninsula were generated from Victoreen-491 measurement and calculation of radioelement content in soil which were measured by Exploranium GR-320, using IAEA formula. However those data are not be comparable so the exposure rate calculated from Gamma Spectrometer data necessarily to be corrected. The correction factor was determinate by measuring the exposure rate of at the NMDC's back yard selected location using Victoreen-491 and Gamma Spectrometer Exploranium GR-320 . Correction factor was created by comparing mean exposure rate data that calculated from 30 data measured by Gamma Spectrometer instrument and to those Victoreen's exposure rate. Conversion factor was gained from comparing of total count data of Gamma Spectrometer Exploranium GR-320 to Victoreen's exposure rate data. The correction factor of Exploranium GR-320's exposure rate is 0.34 μR/hours, and the conversion factor of total count is 0.0092 μR/hours per c/m. Deviation Victoreen 491 = 4.7 % and Gamma Spectrometer Exploranium GR-320 8.6 %

  6. Relationship between X-ray exposure and malignant transformation in C3H 10T1/2 cells

    International Nuclear Information System (INIS)

    Kennedy, A.R.; Fox, M.; Murphy, G.; Little, J.B.

    1980-01-01

    The appearance of transformed foci after x-irradiation of the C3H 10T1/2 line of murine cells requires extensive proliferation followed by prolonged incubation under conditions of confluence. When the progeny of irradiated cells are resuspended and plated to determine the number of potential transformed foci, the absolute yield is constant over a wide range of dilutions and is similar to that observed in cultures that have not been resuspended. In addition, for cells exposed to a given x-ray dose, the number of transformed foci per dish is independent of the number of irradiated cells. These observations suggest that few, if any, of the transformed clones occur as a direct consequence of the x-ray exposure and challenge the hypothesis that transformed foci are the clonal products of occasional cells that have experienced an x-ray-induced mutational change. Rather, it appears that at least two steps are involved. We suggest that exposure to x-rays results in a change, for example, the induction or expression of some cell function, in many or all of the cells and that this change is transmitted to the progeny of the surviving cells; a consequence of this change is an enhanced probability of the occurrence of a second step, transformation, when these cells are maintained under conditions of confluence

  7. Inverse dose-rate effect for the induction of 6-thioguanine-resistant mutants in Chinese hamster V79-S cells by 60Co gamma rays

    International Nuclear Information System (INIS)

    Crompton, N.E.; Barth, B.; Kiefer, J.

    1990-01-01

    Chinese hamster V79-S cells capable of growing in suspension culture were exposed to 60Co gamma rays at a high dose rate (84 Gy/h), low dose rates (200, 50, and 39 mGy/h), and a spectrum of very low dose rates (between 29 and 4.5 mGy/h). Following time for appropriate expression the cultures were assayed for the induction of 6-thioguanine-resistant mutants. For a given dose, a decrease in mutation induction occurred as the dose rate was reduced from high dose rates to low dose rates. However, further reduction in dose rate resulted in a reverse dose-rate effect, and an increase in the frequency of mutants was observed. The contribution of background mutation frequency to this reverse dose-rate effect was studied, both by examining fluctuations of mutation frequency in nonirradiated culture and by its impact upon the dose-rate-independent nature of the reversed effect, and it was found to be negligible. The physiological state of the suspension culture under periods of protracted exposure to very low dose rates was also investigated. The effect of doubling time, plating efficiency, cell cycle distribution, and sensitivity on survival and mutation were examined. In no case was a change apparent during the very low-dose-rate exposures. The results are discussed in terms of the possible expression of cryptic radiation damage after prolonged culture times and/or the involvement of an error-free repair system which requires a certain amount of radiation damage to become active

  8. On the radiation exposure dose and health management history during 50 years of x-ray working

    International Nuclear Information System (INIS)

    Yoshida, Tomihiro

    1981-01-01

    My X-ray working history has become 50 years at the end of April, 1980. At this chance, the following data were summarized; the case numbers of X-ray photographs (517,132 cases), total amounts of radiation exposure dose (66.85 roentgen) and the results of blood test, which were experienced during past 50 years. The amounts of exposure dose during 35 years till 1965 were measured using my own method, which measured the film blackening as 30 milli-roentgen per week by certain standard method. After 1966 till 1980, the exposure dose were recorded using that of the film-badge service of Nippon Hoan Yohin Kyokai. The total amounts of exposure dose during 50 years were about 1/4 of D = 5 (N - 18). The results of blood test during last 27 years were found to be normal values. Then, it is happy to say that my body has been protected completely, from radiation hazard as a result of taking radiation protection and checking blood test always at my daily radiation works. The data of my own experiences during 50 years are summarized and reported in this paper. (author)

  9. Survey on th incidence of homeless pulmonary tuberculosis infection rate through chest x-ray examination

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Young; Shin, Sung Rae [Dept. of Nursing, Sahmyook University, Seoul (Korea, Republic of); Ryu, Young Hwan [Dept. of Radiology, Seoul Medical Center, Seoul (Korea, Republic of); Lim, Hwan Yeal [Dept. of Medical Business Administration, U1 University, Yeongdong (Korea, Republic of)

    2017-02-15

    This study, Seoul City shelter, you are trying to seek medical cooperation and cure rate increase proposal Yu fndings’s current situation and tuberculosis of homeless tuberculosis. Inspector, and has a total 591 people is targeted to implement an interview after acquiring utilization agreement in studies conducted chest X-ray photography. Of the interview questions, three or more protons, it is determined that the TB symptomatic conducted sputum examination, chest X-ray examination confrms the physician radiology, when sputum examination primarily chromatic fndings the double implemented and conducted by requesting the ship inspection also said inspection sputum acid-fast bacteria if it is true one, respectively. confrmed case result of checking whether there is a difference due to risk factors (Jb) at the chi square black, it was found that there is no statistically significant difference at 95% confidence level. (χ{sup 2}=0.276, p>0.05), suspected case (Ac, Ae) results of examining whether there is a difference due to risk factors in chi square black, that there is a statistically significant difference at 99% confidence level is I found (χ{sup 2}=9.414, p<0.01). The nature of the homeless tuberculosis screening and directed to the distance homeless specifc location are likely to evaluate the actual incidence low and aggressive or management needs, the rationale is allowed insufficient reality is. Through this research, future, for tuberculosis high risk tuberculosis patient, such as homeless to expand the tuberculosis screening of infectious tuberculosis patients in private medical institutions, and one-stop service that chest X-ray examination and sputum examination is carried out at the same time introduced immediately to prevent the inspection and examination, cure, and should establish a foundation that can be up to post administration.

  10. Survey on th incidence of homeless pulmonary tuberculosis infection rate through chest x-ray examination

    International Nuclear Information System (INIS)

    Kim, Mi Young; Shin, Sung Rae; Ryu, Young Hwan; Lim, Hwan Yeal

    2017-01-01

    This study, Seoul City shelter, you are trying to seek medical cooperation and cure rate increase proposal Yu fndings’s current situation and tuberculosis of homeless tuberculosis. Inspector, and has a total 591 people is targeted to implement an interview after acquiring utilization agreement in studies conducted chest X-ray photography. Of the interview questions, three or more protons, it is determined that the TB symptomatic conducted sputum examination, chest X-ray examination confrms the physician radiology, when sputum examination primarily chromatic fndings the double implemented and conducted by requesting the ship inspection also said inspection sputum acid-fast bacteria if it is true one, respectively. confrmed case result of checking whether there is a difference due to risk factors (Jb) at the chi square black, it was found that there is no statistically significant difference at 95% confidence level. (χ 2 =0.276, p>0.05), suspected case (Ac, Ae) results of examining whether there is a difference due to risk factors in chi square black, that there is a statistically significant difference at 99% confidence level is I found (χ 2 =9.414, p<0.01). The nature of the homeless tuberculosis screening and directed to the distance homeless specifc location are likely to evaluate the actual incidence low and aggressive or management needs, the rationale is allowed insufficient reality is. Through this research, future, for tuberculosis high risk tuberculosis patient, such as homeless to expand the tuberculosis screening of infectious tuberculosis patients in private medical institutions, and one-stop service that chest X-ray examination and sputum examination is carried out at the same time introduced immediately to prevent the inspection and examination, cure, and should establish a foundation that can be up to post administration

  11. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  12. Effect of dose rate and exposure time on the stimulation effect of tube growth of Pinus sylvestris pollen

    International Nuclear Information System (INIS)

    Zelles, L.; Fendrik, I.; Technische Univ. Hannover

    1975-01-01

    The stimulating effect of ionizing radiation in respect to dose rate and exposure time was studied using the tube growth of Pinus silvestris pollen. Stimulation was registered with a small dose (50 rad) supplied at low dose rates (0.5; 1.0; 3.0 and 5.0 rad/sec) and with higher doses (300; 800 and 1,400 rad) supplied at higher dose rates (10; 40 and 50 rad/sec). This suggests that only the exposure time is of importance for radiation-induced stimulation provided that the exposure time does not exceed 100 sec. (orig.) [de

  13. Investigation of exposure rates and radionuclide and trace metal distributions along the Hanford Reach of the Columbia River

    International Nuclear Information System (INIS)

    Cooper, A.T.; Woodruff, R.K.

    1993-09-01

    Studies have been conducted to investigate exposure rates, and radionuclide and trace metal distributions along the Columbia River where it borders the Hanford Site. The last major field study was conducted in 1979. With recently renewed interest in various land use and resource protection alternatives, it is important to have data that represent current conditions. Radionuclides and trace metals were surveyed in Columbia River shoreline soils along the Hanford Site (Hanford Reach). The work was conducted as part of the Surface Environmental Surveillance Project, Pacific Northwest Laboratory. The survey consisted of taking exposure rate measurements and soil samples primarily at locations known or expected to have elevated exposure rates

  14. Bacterial Community Dynamics and Biodegradation Rates in Untreated and Oily Soils During PAH Exposure

    International Nuclear Information System (INIS)

    Zakaria, A.E.M.

    2008-01-01

    The approach taken in this study represents an attempt to address the possible selective effects of Polycyclic aromatic hydrocarbons (PAH) on the bacterial community structure of an untreated garden soil (S) and a chronically contaminated oily soil (CS). Untreated and chronically hydrocarbon polluted soils, collected from Egypt were enriched in shaking flasks containing 50 mg/l anthracene as a sole source of carbon over a period of 15 days. Bacterial communities in each soil were profiled by denaturing gradient gel electrophoresis (DGGE) analysis of the PCR amplified 16 S r DNA gene fragments after 0, 5, 10, and 15 days. Culture able biodegrading bacterial counts on minerals- Silica gel- Oil (MSD) plates as well as anthracene degradation for both soils were followed up at the same time intervals. Nine bacterial species were found to be dominant in the pristine soil before enrichment with the model polycyclic aromatic hydrocarbon (PAH), eight of them disappeared after live days of enrichment with the domination of one new species. It stayed dominant in soil until 15 days - exposure to anthracene. Therefore it can be used as a bio marker for PAH pollution. The chronically contaminated soil revealed a remarkable increase in the diversity directly after 5 days exposure to PAH HPLC analysis of the extracted anthracene remained in the biodegradation flasks after different degradation periods revealed that a higher biodegradation rates were accomplished by the oily soil consortium rather than by the pristine one. Before exposure to PAH, counts of culture able biodegrading bacteria were found to be higher in the untreated soil rather than in the oily one. After exposure the situation has been a bit altered as the counts in the untreated soil revealed a temporary suppression with a prolongation of the time required for growth as a result of the hydrocarbon stress

  15. Exchange Rate Exposure Management: An Empirical Study into the Strategies of Industrial Companies

    DEFF Research Database (Denmark)

    Aabo, Tom

    1999-01-01

    that major reasons behind this focus are the dynamic development of the competitive environment and the ability of the specific company to counter unfavorable changes in exchange rates by the exercise of real options (e.g. reallocation of production resources). As such, the study shows the in adequacy......This cross-case study of eight blue-chip industrial companies extends previous studies of why exchange rate exposure management is done the way it is. While hedging should not be pursued unless it creates value, the operational objectives differ among companies. Avoiding financial distress...... is considered one of the most important ways of adding value by hedging. However, reducing stakeholders perceived risk and improving the ability to pursue investment plans and make value adding investments do also get some attention. While the overall objective is to add value, the dominating object...

  16. Modelling radiation exposure in homes from siporex blocks by using exhalation rates of radon

    Directory of Open Access Journals (Sweden)

    Nikolić Mladen D.

    2015-01-01

    Full Text Available Building materials are the second major source of indoor radon, after soil. The contribution of building materials to indoor radon amount depends upon the radium content and exhalation rates, which can be used as a primary index for radon levels in the dwellings. This paper presents the results of using the experimentally determined exhalation rates of siporex blocks and concrete plates, to assess the radiation exposure in dwellings built of siporex blocks. The annual doses in rooms have been estimated depending on the established modes of ventilation. Realistic scenario was created to predict an annual effective dose for an old person, a housewife, a student, and an employed tenant, who live in the same apartment, spending different periods of time in it. The results indicate the crucial importance of good ventilation of the living space.

  17. A HIGH REPETITION RATE VUV-SOFT X-RAY FEL CONCEPT

    International Nuclear Information System (INIS)

    Corlett, J.; Byrd, J.; Fawley, W.M.; Gullans, M.; Li, D.; Lidia, S.M.; Padmore, H.; Penn, G.; Pogorelov, I.; Qiang, J.; Robin, D.; Sannibale, F.; Staples, J.W.; Steier, C.; Venturini, M.; Virostek, S.; Wan, W.; Wells, R.; Wilcox, R.; Wurtele, J.; Zholents, A.

    2007-01-01

    We report on design studies for a seeded FEL light source that is responsive to the scientific needs of the future. The FEL process increases radiation flux by several orders of magnitude above existing incoherent sources, and offers the additional enhancements attainable by optical manipulations of the electron beam: control of the temporal duration and bandwidth of the coherent output, reduced gain length in the FEL, utilization of harmonics to attain shorter wavelengths, and precise synchronization of the x-ray pulse with seed laser systems. We describe an FEL facility concept based on a high repetition rate RF photocathode gun, that would allow simultaneous operation of multiple independent FEL's, each producing high average brightness, tunable over the VUV-soft x-ray range, and each with individual performance characteristics determined by the configuration of the FEL. SASE, enhanced-SASE (ESASE), seeded, harmonic generation, and other configurations making use of optical manipulations of the electron beam may be employed, providing a wide range of photon beam properties to meet varied user demands

  18. Reconstruction of the Exposure Histories of 20 Allan Hills Ordinary Chondrites on the Basis of Cosmogenic 10Be, 26Al, Noble Gases, and Cosmic Ray Tracks

    Science.gov (United States)

    Neupert, U.; Knauer, M.; Michel, R.; Loeken, Th.; Schultz, L.; Dittrich-Hannen, B.; Suter, M.; Kubik, P. W.; Metzler, K.; Romstedt, J.

    1995-09-01

    Twenty ordinary chondrites from the 1988/89 meteorite search (ALH 88004, 88008, 88010, 88011, 88013, 88016 to 88021, 88026 to 88031, 88033, 88039, 88042) [1,2] were investigated for 10Be and 26Al, and for He, Ne and Ar by accelerator and rare gas mass spectrometry, respectively. Cosmic ray tracks were measured in samples of ALH 88019. Using theoretical production rates calculated by a physical model [3] the experimental data are interpreted with respect to the reconstruction of the preatmospheric exposure conditions and exposure histories of the meteoroids. Ordinary chondrites are particularly well suited to exemplify the capabilities of an interpretation of many cosmogenic nuclides measured in one sample. Model calculations of GCR production rates were performed for 10Be, 26Al, 3He, 21Ne, 22Ne and 38Ar as reported elsewhere [4,5]. For all meteorites, except for ALH 88019, the cosmogenic nuclide data can be explained by simple one stage exposure histories between 3 Ma and 44 Ma in meteoroids with radii between 5 cm and 85 cm. Exposure ages were derived from cosmogenic 3He, 21Ne and 38Ar on the basis of the theoretical production rates as function of3He/21Ne and 22Ne/21Ne as well as on the empirical ones proposed by Eugster [6]. The average ratios of exposure ages determined from theoretical production rates to those calculated according to Eugster [6] were 1.08+/-0.11, 1.11+/-0.25 and 1.12+/-0.17 in case of 3He, 21Ne and 38Ar, respectively. Repeated measurements of 10Be and 26Al in ALH 88019 resulted in 10.4+/-1.3 dpm/kg and 5.6+/-0.5 dpm/kg, respectively. But, the cosmogenic rare gas concentrations point to a (single stage) exposure age of 39 Ma in a meteoroid. This is in accordance with a measured cosmic ray track density in olivine of 2.8 * 10^6 cm^-2. The samples are from depths betwen 3 cm and 8 cm. Based on the track data we obtain a minimum meteoroid radius of 8 cm. The low 10Be and 26Al cannot be explained by a one stage exposure history and a long

  19. Gamma ray heating rates due to chromium isotopes in stellar core during late stages of high mass stars (>10M⊙

    Directory of Open Access Journals (Sweden)

    Nabi Jameel-Un

    2017-01-01

    Full Text Available Gamma ray heating rates are thought to play a crucial role during the pre-supernova stage of high mass stars. Gamma ray heating rates, due to β±-decay and electron (positron capture on chromium isotopes, are calculated using proton-neutron quasiparticle random phase approximation theory. The electron capture significantly affects the lepton fraction (Ye and accelerates the core contraction. The gamma rays emitted as a result of weak processes heat the core and tend to hinder the cooling and contraction due to electron capture and neutrino emission. The emitted gamma rays tend to produce enormous entropy and set the convection to play its role at this stage. The gamma heating rates, on 50-60Cr, are calculated for the density range 10 < ρ (g.cm-3 < 1011 and temperature range 107 < T (K < 3.0×1010.

  20. APPLE-2: an improved version of APPLE code for plotting neutron and gamma ray spectra and reaction rates

    International Nuclear Information System (INIS)

    Kawasaki, Hiromitsu; Seki, Yasushi.

    1982-07-01

    A computer code APPLE-2 which plots the spatial distribution of energy spectra of multi-group neutron and/or gamma ray fluxes, and reaction rates has been developed. This code is an improved version of the previously developed APPLE code and has the following features: (1) It plots energy spectra of neutron and/or gamma ray fluxes calculated by ANISN, DOT and MORSE. (2) It calculates and plots the spatial distribution of neutron and gamma ray fluxes and various types of reaction rates such as nuclear heating rates, operational dose rates, displacement damage rates. (3) Input data specification is greatly simplified by the use of standard, response libraries and by close coupling with radiation transport calculation codes. (4) Plotting outputs are given in camera ready form. (author)

  1. Two survey meters for measuring low γ-ray dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1979-01-01

    Two low-level survey meters have been developed which have numerical displays. The first is of the light-emitting diode (LED) type. The second is a liquid crystal display (LCD). The design of both instruments is described and results of measurements of performance are presented. They measure γ dose rates from background up to 2 mrad/h (20 μGy/h) for γ-rays in the energy range 0.05-1.25 MeV. They can be used at temperatures between -20 deg C and +50 deg C. Statistical accuracy and battery life both depend upon a number of factors and this dependence is shown. A later section describes the intended application of the survey meters. An appendix describes the circuit adjustments which are necessary and when they must be made. (author)

  2. Configuration interaction calculations and excitation rates of X-ray and EUV transitions in sulfurlike manganese

    Energy Technology Data Exchange (ETDEWEB)

    El-Maaref, A.A., E-mail: ahmed.maaref@azhar.edu.eg; Saddeek, Y.B.; Abou halaka, M.M.

    2017-02-15

    Highlights: • Fine-structure calculations of sulfurlike Mn have been performed using configuration interaction technique, CI. • The relativistic effects, Breit-Pauli Hameltonian, have been correlated to the CI calculations. • Excitation rates by electron impact of the Mn X ion have been evaluated up to ionization potential. - Abstract: Fine-structure calculations of energies and transition parameters have been performed using the configuration interaction technique (CI) as implemented in CIV3 code for sulfurlike manganese, Mn X. The calculations are executed in an intermediate coupling scheme using the Breit-Pauli Hamiltonian. As well as, energy levels and oscillator strengths are calculated using LANL code, where the calculations by LANL have been used to estimate the accuracy of the present CI calculations. The calculated energy levels, oscillator strengths, and lifetimes are in reasonable agreement with the published experimental and theoretical values. Electron impact excitation rates of the transitions emit soft X-ray and extreme ultraviolet (EUV) wavelengths have been evaluated. The level population densities are calculated using the collisional radiative model (CRM), as well. The collisional excitation rates and collision strengths have been calculated in the electron temperature range ≤ the ionization potential, ∼1–250 eV.

  3. Ice-based altitude distribution of natural radiation annual exposure rate in the Antarctica zone over the latitude range 69 degrees S-77 degrees S using a pair-filter thermoluminescence method.

    Science.gov (United States)

    Nakajima, T; Kamiyama, T; Fujii, Y; Motoyama, H; Esumi, S

    1995-12-01

    Both ice-based altitude distributions of natural ionizing radiation exposure and the quasi-effective energy of natural radiation over Antartica over the latitude range 69 degrees S - 77 degrees S during approx. 500 days were measured using thermoluminescent dosimeters. The results shows that dependence on altitude above sea level of the exposure rate increases by almost three-fold with each increase of 2000 m of altitude, thus deviating from the general rule stating that the exposure rate should double with each 2000 m. Although the exposure rate shows a dependence on altitude, altitude dependence of the quasi-effective energy of natural radiation over Antartica is not observed. In the present study it is observed that natural radiation occurring over the ice base of Antartica consists mainly of cosmic rays.

  4. Ice-based altitude distribution of natural radiation annual exposure rate in the Antarctica zone over the latitude range 69 deg S-77 deg S using a pair-filter thermoluminescence method

    International Nuclear Information System (INIS)

    Nakajima, Toshiyuki; Kamiyama, Takayoshi; Fujii, Yoshiyuki; Motoyama, Hideaki; Esumi, Shuuichi

    1995-01-01

    Both ice-based altitude distributions of natural ionizing radiation exposure and the quasi-effective energy of natural radiation over Antarctica over the latitude range 69 o S-77 o S during approx. 500 days were measured using thermoluminescent dosimeters. The results shows that dependence on altitude above sea level of the exposure rate increases by almost three-fold with each increase of 2000 m of altitude, thus deviating from the general rule stating that the exposure rate should double with each 2000 m. Although the exposure rate shows a dependence on altitude, altitude dependence of the quasi-effective energy of natural radiation over Antarctica is not observed. In the present study it is observed that natural radiation occurring over the ice base of Antarctica consists mainly of cosmic rays. (Author)

  5. External exposure rates from terrestrial radiation at Guarapari and Meaipe in Brazil

    International Nuclear Information System (INIS)

    Fujinami, N.; Koga, T.; Morishima, H.

    2000-01-01

    Recently epidemiological and cytogenetic studies on inhabitants living in high background radiation areas have been carried out in order to examine health effects of exposure to low dose radiation. Guarapari and Meaipe are towns built on the monazite sand region along the Atlantic coast in Brazil, which is one of the widely known high background radiation areas in the world. As an initial step toward studies on health effects of high background radiation on inhabitants living in Guarapari and Meaipe, we surveyed absorbed dose rates in air in these towns with a portable NaI(Tl) scintillation detector in September 1998. Sand and soil were also sampled there so as to determine the concentrations of Th-232 and Ra-226 in them. In Guarapari and Meaipe, dose rates in the streets ranged from 0.1 to 0.4 μ Gy/h except for a few places such as near the Areia Preta beach and Meaipe beach. Dose rates inside houses were lower than 0.2 μ Gy/h except that two houses attained a dose rate of 0.4 μ Gy/h. Our effective dose rate from external terrestrial irradiation (outdoors and indoors) was 0.17 μ Sv/h on the average, during the period of our three day stay in Guarapari and Meaipe. From comparison of our present values with those observed in the 1960s, which were cited in UNSCEAR reports, it is indicated that dose rate levels have decreased clearly in downtown, while the levels have scarcely changed in beaches and unpaved beach streets which have not been developed yet. This fact suggests that the natural radiation environment of Guarapari and Meaipe has varied with urbanization which brought paved streets, and changes in the structure and building materials of houses. A detailed survey is necessary in order to evaluate present absorbed dose rates in air in this area. (author)

  6. Radiation exposure and image quality in X-ray diagnostic radiology. Physical principles and clinical applications. 2. ed.

    International Nuclear Information System (INIS)

    Saebel, Manfred; Aichinger, Horst; Dierker, Joachim; Joite-Barfuss, Sigrid

    2012-01-01

    Diagnostic X-rays are the largest contributor to radiation exposure to the general population, and protecting the patient from radiation damage is a major aim of modern health policy. Once the decision has been taken to use ionising radiation for imaging in a particular patient, it is necessary to optimize the image acquisition process taking into account the diagnostic quality of the images and the radiation dose to the patient. Both image quality and radiation dose are affected by a number of parameters, knowledge of which permits scientifically based decision making. The authors of this second edition of Radiation Exposure and Image Quality in X-ray Diagnostic Radiology have spent many years studying the optimization of radiological imaging. In this book they present in detail the basic physical principles of diagnostic radiology and their application to clinical problems. Particular attention is devoted to evaluation of the dose to the patient, the influence of scattered radiation on image quality, the use of antiscatter grids, and optimization of image quality and dose. The final section is a supplement containing tables of data and graphical depictions of X-ray spectra, interaction coefficients, characteristics of X-ray beams, and other aspects relevant to patient dose calculations. In addition, a complementary CD-ROM contains a user-friendly Excel file database covering these aspects that can be used in the reader's own programs. Since the first edition, the text, figures, tables, and references have all been thoroughly updated, and more detailed attention is now paid to image quality and radiation exposure when using digital imaging and computed tomography. This book will be an invaluable aid to medical physicists when performing calculations relating to patient dose and image quality, and will also prove useful for diagnostic radiologists and engineers. (orig.)

  7. Aberrant cell divisions in root meristeme of maize following exposure to X-rays low doses compared to similar effects of 50 Hz electromagnetic exposure

    Directory of Open Access Journals (Sweden)

    Luchian T.

    2012-04-01

    Full Text Available The response of maize to radiation exposure was investigated by two cytogenetic methods considering the importance of the geno-toxic effect for environmental and agricultural purposes. Uniform genophond seeds, freshly germinated, were exposed to relatively low radiation doses using a radiotherapy X-ray applicator from a hospital irradiation device and to a 50 Hz electromagnetic field with about 10 mT magnetic induction (generated within laboratory assembled electromagnetic coils. Radicular meristeme tissue aliquots were prevailed for cytogenetic investigation based on microscopic observations and cell counting. Microscope slides were prepared following a specific procedure (squash technique and Feulgen method based on modified Carr reactive coloration. Mitotic index as well as chromosomal aberration percentage were calculated for more than 30,000 cells taken into account. From a qualitative viewpoint, chromosomal aberrations such as interchromatidian bridges, lagging and expelled chromosomes and multipolar divisions were evidenced - no distinct situation for either ionizing radiation or electromagnetic field being identified. The main quantitative difference consisted in the increased mitotic index for electromagnetic exposure increased times compared with the diminished mitotic index in the case of low X-ray doses.

  8. Exposure assessment of neonates in israel to x-ray radiation during hospitalization at neonatal intensive care unit

    International Nuclear Information System (INIS)

    Datz, H.

    2005-03-01

    Nowadays nearly 10% of all births in western countries are premature. In the last decade, there has been an increase of 45% in the number of neonates that were born in Israel. At the same time, the survival of neonates, especially those with very low birth weight, VLBW, (less than 1,500 gr), has increased dramatically. Diagnostic radiology plays an important role in the assessment and treatment of neonates requiring intensive care. During their prolonged and complex hospitalization, these infants are exposed to multiple radiographic examinations involving X-ray radiation. The extent of the examinations that the infant undergoes depends on its birth weight, gestational age and its medical problems, where most of the treatment effort is focused especially on VLBW neonates. Most of the diagnostic X-ray examinations taken during the hospitalization of neonates in the neonatal intensive care unit (NICU) consist of imaging of the respiratory and gastrointestinal systems, namely, the chest and abdomen. The imaging process is done using mobile X-ray units located at the NICUs. Due to their long hospitalization periods and complex medical condition, all neonates, and neonates with VLBW in particular, are exposed to a much higher level of diagnostic radiation, compared to normal newborns. The goal of this research was to assess the extent of the exposure of neonates in Israel to X-ray radiation during their hospitalization at the neonatal intensive care unit. Five NICUs, located at different geographical zones in Israel and treating 20% of all newborns in Israel every year, participated in this research. The research was conducted in three phases: Phase I: Collection of information on radiographic techniques and exposure parameters (e.g. kV, mAs, focus to skin distance (FSD), examination borders). 499 X-ray examinations (from 157 neonates) were evaluated for necessary and unnecessary exposure of the neonate's organs to X-ray radiation during these examinations. Phase II

  9. Acute myeloid leukemia induction in CBA/H mice by irradiation with fission neutrons as a function of exposure rate

    International Nuclear Information System (INIS)

    Huiskamp, R.

    1991-01-01

    Radiation-induced acute myeloid leukemia (AML) in male CBA/H mice was used as a model for investigation of the effect of reduced fast fission neutron exposure rates on radiation-induced carcinogenesis. Groups of about 90 male CBA/H mice were irradiated or sham-irradiated at the age of 15-20 weeks. The animals were exposed to 400 mGy fast fission neutrons at exposure rates of 2, 10 or 100 mGy/min. The investigation clearly showed that reducing the exposure rate of high-LET fast fission neutrons had no influence on the incidence of AML or on the survival of the irradiated mice. In contrast, a higher incidence of lymphosarcomas was observed in mice irradiated with higher exposure rates. (orig./MG)

  10. Acute myeloid leukemia induction in CBA/H mice by irradiation with fission neutrons as a function of exposure rate

    Energy Technology Data Exchange (ETDEWEB)

    Huiskamp, R [Stichting Energieonderzoek Centrum Nederland, Petten (Netherlands). Radiobiology and Radio-Ecology Unit

    1991-06-01

    Radiation-induced acute myeloid leukemia (AML) in male CBA/H mice was used as a model for investigation of the effect of reduced fast fission neutron exposure rates on radiation-induced carcinogenesis. Groups of about 90 male CBA/H mice were irradiated or sham-irradiated at the age of 15-20 weeks. The animals were exposed to 400 mGy fast fission neutrons at exposure rates of 2, 10 or 100 mGy/min. The investigation clearly showed that reducing the exposure rate of high-LET fast fission neutrons had no influence on the incidence of AML or on the survival of the irradiated mice. In contrast, a higher incidence of lymphosarcomas was observed in mice irradiated with higher exposure rates. (orig./MG).

  11. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  12. X-ray diagnostic study on the optimization of digital radiography in dentistry. Optimal exposure conditions for X-ray CCD sensor

    International Nuclear Information System (INIS)

    Hakata, Toshifumi

    2002-01-01

    The purpose of this research is to reduce the patient dose by optimization of irradiation conditions of an X-ray CCD sensor in intra-oral digital radiography. The X-ray diagnosis was divided into two, high quality-of-image diagnosis and low quality-of-image diagnosis, and it optimized by using the exposure of necessary minimum for each. The image quality of CCD was evaluated using the signal-to-noise ratio (SNR) in order to estimate the influence of irradiation conditions. The dose based on CCD maker setting value was set up so that the highest quality of image might be obtained mostly. In low quality-of-image diagnosis, even if it reduced the dose to 13.2% of standard irradiation, SNR was 40% and interpretation was possible. In high quality-of-image diagnosis, even if it reduces the dose to 49% of standard irradiation, SNR remained 80% and there were few differences of the image with a standard. A study of the digital X-ray examination taken at the dental clinic showed high quality-of-image diagnosis was 69% and low quality-of-image one was 31%. When this optimization was performed, it was presumed that reduction of about 62% of the dose is possible. (author)

  13. Evaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulation

    International Nuclear Information System (INIS)

    Santos, Felipe A.; Galeano, Diego C.; Santos, William S.; Carvalho Júnior, Albérico B.

    2016-01-01

    In this work irradiation scenarios that simulated chest and abdomen examinations involving mobile X-ray equipment in hospitals were modeled with the purpose of calculating conversion coefficient for effective dose (CC E ), normalized to entrance surface dose (ESD), applied to patients and public individuals. These coefficients can easily be used in this practice. Patients and public individuals were represented by a pair of anthropomorphic phantoms inserted in the MCNPX 2.7.0 radiation transport code. One of the phantoms (patient) was irradiated with the direct beam simulating examinations of the chest and abdomen, each with two fields of irradiation, ideal (IF) and extrapolated (EF). Using the software SPECGEN X-ray spectra from 60 to 100 kVp at 10 kVp intervals were generated and used in this work. The other phantom (public individual) was positioned 50–200 cm from the patient. In relation to the CC E calculated in the patient, the average increase obtained between the irradiation fields was 62.4% for the chest examinations, and for the same conditions the CC E was calculated for abdomen examinations and found to be 8.0%. Increasing the distance between public individual and patient, reductions of up to 81.7% in the CC E in abdomen examinations and 83.4% in chest examinations were observed. Through the assessment of CC E of these scenarios, it is possible to measure the damages relating to this practice for both patients and public individuals. - Highlights: • A computational scenario involving mobile X-ray equipment in hospitals were modeled. • Evaluation of medical exposure and exposure by the public was made by CC E (E/ESD). • A pair of the anthropomorphic simulators was inserted into the input file MCNPX. • Analyze the influence in CC E for the different types of fields used in examinations. • Monitoring the reduction of CC E 's with increasing distance between the beds.

  14. Star formation rates and stellar masses in z ~ 1 gamma-ray burst hosts

    DEFF Research Database (Denmark)

    Castro Cerón, José María; Michalowski, Michal; Hjorth, J.

    2006-01-01

    Cosmology: Observations, ISM: Dust, Extinction, Galaxies: High-Redshift, Galaxies: ISM, Gamma Rays: Bursts, Infrared: Galaxies Udgivelsesdato: Dec. 4......Cosmology: Observations, ISM: Dust, Extinction, Galaxies: High-Redshift, Galaxies: ISM, Gamma Rays: Bursts, Infrared: Galaxies Udgivelsesdato: Dec. 4...

  15. The calculation of individual radiation exposure rates arising from routine discharges of activity into an estuary or sea

    International Nuclear Information System (INIS)

    Maul, P.R.

    1982-03-01

    Simple methods are described which enable assessments to be made of exposure rates to individuals arising from the release of activity into an estuary or sea. These methods are based in the main on those employed by the Ministry of Agriculture Fisheries and Food together with models developed by the author. The exposure routes considered are the ingestion of seafood and external exposure from β and γ emitters arising from occupancy over contaminated sediments or beaches and the handling of fishing gear. These routes are generally the most important, but for any chosen site it will also be necessary to determine whether any other exposure routes are significant. (author)

  16. The calculation of individual radiation exposure rates arising from routine discharges of activity into an estuary or sea

    International Nuclear Information System (INIS)

    Maul, P.R.

    1982-11-01

    Simple methods are described which enable assessments to be made of exposure rates to individuals arising from the release of activity into an estuary or sea. These methods are based in the main on those employed by the Ministry of Agriculture Fisheries and Food together with models developed by the author. The exposure routes considered are the ingestion of seafood and external exposure from ν and ν emitters arising from occupancy over contaminated sediments or beaches and the handling of fishing gear. These routes are generally the most important, but for any chosen site it will also be necessary to determine whether any other exposure routes are significant. (author)

  17. Trends in x-ray photography and patient exposure dose. Questionnaire survey results compared with those in 1973. [questionnaire survey in 1979

    Energy Technology Data Exchange (ETDEWEB)

    Orito, T; Sanada, S; Maekawa, R; Koshida, K; Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine

    1980-04-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired.

  18. The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

    Directory of Open Access Journals (Sweden)

    Mehrdad Gholami

    2015-07-01

    Full Text Available Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation dose. Materials and Methods This cross-sectional study was performed on seven stationary X-ray units in sixhospitals of Lorestan province. The measurements were performed, using a factory-calibrated Barracuda dosimeter (model: SE-43137. Results According to the results, the highest output was obtained in A Hospital (M1 device, ranging from 107×10-3 to 147×10-3 mGy/mAs. The evaluation of tube voltage accuracy showed a deviation from the standard value, which ranged between 0.81% (M1 device and 17.94% (M2 device at A Hospital. The deviation ranges at other hospitals were as follows: 0.30-27.52% in B Hospital (the highest in this study, 8.11-20.34% in C Hospital, 1.68-2.58% in D Hospital, 0.90-2.42% in E Hospital and 0.10-1.63% in F Hospital. The evaluation of exposure time accuracy showed that E, C, D and A (M2 device hospitals complied with the requirements (allowing a deviation of ±5%, whereas A (M1 device, F and B hospitals exceeded the permitted limit. Conclusion The results of this study showed that old X-ray equipments with poor or no maintenance are probably the main sources of reducing radiographic image quality and increasing patient radiation dose.

  19. Technical study on reduction of patient exposure in x-ray examination

    International Nuclear Information System (INIS)

    Ohtsuka, Akiyoshi

    1983-01-01

    This paper deals with the necessity, problems and technical factors on the reduction of the patient exposure, as well as the source of disagreement between doctors and radiologic technologists with respect to their psychological evaluation of the radiological image quality. (1) The patient exposure has a close relationship to the radiological image quality and is affected by many physical and psychological factors. (2) From the patient's point of view, reduction of the patient exposure without the decrease of the image quality has the same meaning as improving the image quality without the increase of the patient exposure. (3) It is known that, in the observation of the radiological image, the radiologic technologists basically attach more importance to the physical evaluation while doctors attach more importance to the psychological evaluation. (4) If doctors and radiologic technologists have more knowledge concerning the radiological imaging technology, optimization of radiographic technique, reduction of the patient exposure and improvement of the diagnostic accuracy can be expected. (author)

  20. Different gene expression of Normal lymphobloastoid cells which exposure to different dose of 60Co γ-ray

    International Nuclear Information System (INIS)

    Xiao Yao; Yang Jian; Gao Xian; Qin Yanghua; Sun Ding; Hai Ling

    2008-01-01

    Objective: To study on the gene expression of normal lymphoblastoid cells(AHH-1) which exposure to difference dose of 60 Co γ-ray, analyses the essential different biological effect.. Methods Human AHH-1 normal line was irradiated by 60 Co γ-rays. Used human cDNA microarray to develop the transcriptional levels of the genes by hybridizing the mRNA of cells 8 h after exposured in different dose and the control cells. Cluster analysis, discrimination and bolting were used to filter the effective genes of differential expression. Results The results of data analysis showed 23 genes of differential expression closely related to biological effect of 2.0 Gy radiation, 5 genes express changed only by 0.5 Gy radiation, 5 genes express apparently both in 2.0 Gy and 0.5 Gy radiation. Conclusion: The different dose γ-rays radiation-induced significant changes in gene expression, such as PAPLN, TP53INP1, PTENP1, FOS and TPR seem to be some important components of cellular radioresponse. (authors)

  1. Exposure assessment and heart rate variability monitoring in workers handling titanium dioxide particles: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Ichihara, Sahoko [Mie University, Graduate School of Regional Innovation Studies (Japan); Li, Weihua [WHO Collaborating Centre for Research in Human Reproduction, Shanghai Institute of Planned Parenthood Research (China); Omura, Seiichi [Tokyo Institute of Technology (Japan); Fujitani, Yuji [National Institute for Environmental Studies (Japan); Liu, Ying; Wang, Qiangyi [WHO Collaborating Centre for Research in Human Reproduction, Shanghai Institute of Planned Parenthood Research (China); Hiraku, Yusuke [Mie University Graduate School of Medicine, Department of Environmental and Molecular Medicine (Japan); Hisanaga, Naomi [Aichi Gakusen University, Faculty of Human Science and Design (Japan); Wakai, Kenji [Nagoya University Graduate School of Medicine, Department of Preventive Medicine (Japan); Ding, Xuncheng [WHO Collaborating Centre for Research in Human Reproduction, Shanghai Institute of Planned Parenthood Research (China); Kobayashi, Takahiro, E-mail: takakoba@airies.or.jp [Association for International Research Initiatives for Environmental Studies (Japan); Ichihara, Gaku, E-mail: gak@rs.tus.ac.jp [Tokyo University of Science, Department of Occupational and Environmental Health, Faculty of Pharmaceutical Sciences (Japan)

    2016-03-15

    Titanium dioxide (TiO{sub 2}) particles are used for surface coating and in a variety of products such as inks, fibers, food, and cosmetics. The present study investigated possible respiratory and cardiovascular effects of TiO{sub 2} particles in workers exposed to this particle at high concentration in a factory in China. The diameter of particles collected on filters was measured by scanning electron microscopy. Real-time size-dependent particle number concentration was monitored in the nostrils of four workers using condensation particle counter and optical particle counter. Electrocardiogram was recorded using Holter monitors for the same four workers to record heart rate variability. Sixteen workers underwent assessment of the respiratory and cardiovascular systems. Mass-based individual exposure levels were also measured with personal cascade impactors. The primary particle diameter ranged from 46 to 562 nm. Analysis of covariance of the pooled data of the four workers showed that number of particles with a diameter <300 nm was associated positively with total number of N–N and negatively with total number of increase or decrease in successive RR intervals greater than 50 ms (RR50+/−) or percentage of RR 50+/− that were parameters of parasympathetic function. The total mass concentration was 9.58–30.8 mg/m{sup 3} during work, but significantly less before work (0.36 mg/m{sup 3}). The clear abnormality in respiratory function was not observed in sixteen workers who had worked for 10 months to 13 years in the factory. The study showed that exposure to particles with a diameter <300 nm might affect HRV in workers handling TiO{sub 2} particles. The results highlight the need to investigate the possible impact of exposure to nano-scaled particles on the autonomic nervous system.

  2. The morphofunctional state of Purkin'e cells in the cerebellum of new-born rats following laser and gamma-ray exposure

    International Nuclear Information System (INIS)

    Zubkova, S.M.; Popov, V.I.

    1993-01-01

    Following of local laser (632.8 nm, 6.3. J/cm 2 ) and whole-body Gy gamma-ray exposures of new-born rats the contrast changes of morphometrical indices, RNA amount, and chromatophilia of Purkin'e cells in the cerebellum were seen. The preliminary laser exposure of new-born rat cerebellum artially increased activity of karyogene structures of the cerebellum cells which were inhibited by 6.37 Gy gamma-rays

  3. The Relationship of Practice Exposure and Injury Rate on Game Performance and Season Success in Professional Male Basketball

    Directory of Open Access Journals (Sweden)

    Toni Caparrós, Eduard Alentorn-Geli, Gregory D. Myer, Lluís Capdevila, Kristian Samuelsson, Bruce Hamilton, Gil Rodas

    2016-09-01

    Full Text Available The objectives of this study were to determine the relationship among game performance, injury rate, and practice exposure in a professional male basketball team. A retroospective analysis of prospective collected data was conducted over seven consecutive seasons (2007/2008 to 2013/2014. Data collection included sports performance during competition (statistical evaluation, injury rate, and total exposure (games and practices. Over the surveillance period, 162 injuries (91 practice; 71 matches occurred over 32,668 hours of exposure (556 games and 2005 practices. There was a strong positive correlation between: 1 exposure (total number of practices and hours of exposure and the total number of injuries (r = 0.77; p = 0.04; 2 exposure (total hours of exposure and total hours of practice exposure and performance (total team ranking (r = 0.77 and p = 0.04, and r = 0.8 and p = 0.03, respectively; and 3 total number of injuries and performance (total team ranking (r = 0.84; p = 0.02. While increasing practice and competition time is related to greater team performance, it also increases the number of injuries. However, higher injury rates were not associated with worse overall team performance. Efforts to reduce high-risk activity during practice, optimally replaced with injury prevention training, might help to reduce injury risk.

  4. Combined methodology for estimating dose rates and health effects from exposure to radioactive pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, D.E. Jr.; Leggett, R.W.; Yalcintas, M.G.

    1980-12-01

    The work described in the report is basically a synthesis of two previously existing computer codes: INREM II, developed at the Oak Ridge National Laboratory (ORNL); and CAIRD, developed by the Environmental Protection Agency (EPA). The INREM II code uses contemporary dosimetric methods to estimate doses to specified reference organs due to inhalation or ingestion of a radionuclide. The CAIRD code employs actuarial life tables to account for competing risks in estimating numbers of health effects resulting from exposure of a cohort to some incremental risk. The combined computer code, referred to as RADRISK, estimates numbers of health effects in a hypothetical cohort of 100,000 persons due to continuous lifetime inhalation or ingestion of a radionuclide. Also briefly discussed in this report is a method of estimating numbers of health effects in a hypothetical cohort due to continuous lifetime exposure to external radiation. This method employs the CAIRD methodology together with dose conversion factors generated by the computer code DOSFACTER, developed at ORNL; these dose conversion factors are used to estimate dose rates to persons due to radionuclides in the air or on the ground surface. The combination of the life table and dosimetric guidelines for the release of radioactive pollutants to the atmosphere, as required by the Clean Air Act Amendments of 1977.

  5. Estimating dose rates to organs as a function of age following internal exposure to radionuclides

    International Nuclear Information System (INIS)

    Leggett, R.W.; Eckerman, K.F.; Dunning, D.E. Jr.; Cristy, M.; Crawford-Brown, D.J.; Williams, L.R.

    1984-03-01

    The AGEDOS methodology allows estimates of dose rates, as a function of age, to radiosensitive organs and tissues in the human body at arbitrary times during or after internal exposure to radioactive material. Presently there are few, if any, radionuclides for which sufficient metabolic information is available to allow full use of all features of the methodology. The intention has been to construct the methodology so that optimal information can be gained from a mixture of the limited amount of age-dependent, nuclide-specific data and the generally plentiful age-dependent physiological data now available. Moreover, an effort has been made to design the methodology so that constantly accumulating metabolic information can be incorporated with minimal alterations in the AGEDOS computer code. Some preliminary analyses performed by the authors, using the AGEDOS code in conjunction with age-dependent risk factors developed from the A-bomb survivor data and other studies, has indicated that the doses and subsequent risks of eventually experiencing radiogenic cancers may vary substantially with age for some exposure scenarios and may be relatively invariant with age for other scenarios. We believe that the AGEDOS methodology provides a convenient and efficient means for performing the internal dosimetry

  6. The evaluation the magnitude radiation exposure dose rate in digital radiography room design

    Science.gov (United States)

    Dwiyanto, Agung; Setia Budi, Wahyu; Hardiman, Gagoek

    2017-12-01

    This study discusses the dose rate in digital radiography room, buit according to meet the provisions of KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation of BAPETEN No. 8 / 2011. The provisions primary concern of radiation safety, not comfort, by considering the space design. There are five aspects to consider in designing the space: functionality, comfort, security, movement activities and aesthetics. However provisions only met three aspects of the design, which are a function, security and movement activity. Therefore, it is necessary to evaluate digital radiography room in terms of its ability to control external radiation exposure to be safe and comfortable The dose rate is measured by the range of primary and secondary radiation in the observation points by using Surveymeter. All data are obtained by the preliminary survey prior to the study. Furthermore, the review of digital radiography room is done based on architectural design theory. The dose rate for recommended improvement room is recalculated using the same method as the actual room with the help of computer modeling. The result of dose rate calculation at the inner and outer part of digital radiography observation room shows that in-room dose for a week at each measuring point exceeds the allowable dose limit both for staff and public. During a week of observation, the outdoor dose at some measuring points exceeds the dose limit set by the KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation BEPETEN No 8/2011. Meanwhile, the result of dose rate calculation in the inner and outer part of the improved digital radiography room can meet the applicable regulations better.

  7. Breathing rates and daily activities: parameters of exposure to inhaled substances

    International Nuclear Information System (INIS)

    Roy, M.; Malarbet, J.L.; Courtay, C.

    1993-01-01

    The intake of inhaled toxic substances is based upon the air volumes breathed every day by people under exposure to gases and aerosols. On the occasion of the revision of the respiratory tract model by the International Commission on Radiological Protection (ICRP), modern standards have been assessed for average inspired air volumes according to age and sex. Recent data of breathing rates as a function of physical activity have been recorded, and economical surveys recently published by the National Institute of Statistics and Economical studies (INSEE) provided time budgets and activities of specific categories of the population. The results were calculated for adults and children, 3 months, 1, 5, 10 and 15 years old. These values are slightly different from those formerly published by ICRP and the United Nations scientific committee on the effects of atomic radiation (UNSCEAR). (author). 27 refs., 6 tabs

  8. Features of working in fields with high values of exposure dose rate

    International Nuclear Information System (INIS)

    Samojlenko, Yu.N.

    1989-01-01

    Features of working in fields with the exposure dose rate (EDR) ∼ 1000-7000 R/h are described. Data on the performed operations concerning initial decontamination of the Chernobyl-3 reactor roof during 10.07.86-03.10.86 are presented. It is marked that the methodical recommendations on working in fields with high values of EDR are absent in our country and abroad and it is necessary to develop them on the basis of obtained experience. Moreover, there are no protective means (protective clotting). Main principles of its creation are the protection of critical organ groups and comfort in working. Personnel should be specially trained and get phychologically ready. 2 figs., 1 tab

  9. Guest–Host Interactions Investigated by Time-Resolved X-ray Spectroscopies and Scattering at MHz Rates

    DEFF Research Database (Denmark)

    Haldrup, Martin Kristoffer; Vanko, G.; Gawelda, W.

    2012-01-01

    We have studied the photoinduced low spin (LS) to high spin (HS) conversion of [Fe(bipy)3]2+ in aqueous solution. In a laser pump/X-ray probe synchrotron setup permitting simultaneous, time-resolved X-ray diffuse scattering (XDS) and X-ray spectroscopic measurements at a 3.26 MHz repetition rate...... lifetime, allowing the detection of an ultrafast change in bulk solvent density. An analysis approach directly utilizing the spectroscopic data in the XDS analysis effectively reduces the number of free parameters, and both combined permit extraction of information about the ultrafast structural dynamics...

  10. Gamma exposure rate estimation in irradiation facilities of nuclear research reactors

    International Nuclear Information System (INIS)

    Daoud, Adrian

    2009-01-01

    There are experimental situations in the nuclear field, in which dose estimations due to energy-dependent radiation fields are required. Nuclear research reactors provide such fields under normal operation or due to radioactive disintegration of fission products and structural materials activation. In such situations, it is necessary to know the exposure rate of gamma radiation the different materials under experimentation are subject to. Detectors of delayed reading are usually used for this purpose. Direct evaluation methods using portable monitors are not always possible, because in some facilities the entrance with such devices is often impracticable and also unsafe. Besides, these devices only provide information of the place where the measurement was performed, but not of temporal and spatial fluctuations the radiation fields could have. In this work a direct evaluation method was developed for the 'in-situ' gamma exposure rate for the irradiation facilities of the RA-1 reactor. This method is also applicable in any similar installation, and may be complemented by delayed evaluations without problem. On the other hand, it is well known that the residual effect of radiation modifies some properties of the organic materials used in reactors, such as density, colour, viscosity, oxidation level, among others. In such cases, a correct dosimetric evaluation enables in service estimation of material duration with preserved properties. This evaluation is for instance useful when applied to lubricating oils for the primary circuit pumps in nuclear power plants, thus minimizing waste generation. In this work the necessary elements required to estimate in-situ time and space integrated dose are also established for a gamma irradiated sample in an irradiation channel of a nuclear facility with zero neutron flux. (author)

  11. A Monte Carlo program to calculate the exposure rate from airborne radioactive gases inside a nuclear reactor containment building.

    Science.gov (United States)

    Sherbini, S; Tamasanis, D; Sykes, J; Porter, S W

    1986-12-01

    A program was developed to calculate the exposure rate resulting from airborne gases inside a reactor containment building. The calculations were performed at the location of a wall-mounted area radiation monitor. The program uses Monte Carlo techniques and accounts for both the direct and scattered components of the radiation field at the detector. The scattered component was found to contribute about 30% of the total exposure rate at 50 keV and dropped to about 7% at 2000 keV. The results of the calculations were normalized to unit activity per unit volume of air in the containment. This allows the exposure rate readings of the area monitor to be used to estimate the airborne activity in containment in the early phases of an accident. Such estimates, coupled with containment leak rates, provide a method to obtain a release rate for use in offsite dose projection calculations.

  12. Investigation of the Effect of Occupational Noise Exposure on Blood Pressure and Heart Rate of Steel Industry Workers

    Science.gov (United States)

    Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan

    2013-01-01

    Background and Objectives. This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. Materials and Methods. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. Results. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). Conclusion. No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels. PMID:23781252

  13. Investigation of the effect of occupational noise exposure on blood pressure and heart rate of steel industry workers.

    Science.gov (United States)

    Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan

    2013-01-01

    This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels.

  14. Ultrastructural changes in spermatogonia of Wistar strain rats following acute whole-body X-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hrehorovsky, M; Horak, J [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes in spermatogonia ultrastructure in rats of Wistar strain after single whole-body X-ray irradiation with 6.4 mC.kg/sup -1/, 25.8 mC.kg/sup -1/ and 51.6 mC.kg/sup -1/ respectively, were studied. Intracellular spaces were found between spermatogonia enlarged, nuclear membranes were bent, the pheripheral teritories of chromation were electronoptically denser, the morphology of nucleoli was changed, cytoplasm was vacuolised, mitochondria were damaged, the vacuolar dilatation of agranular endoplasmic reticulum was evident and electronoptically empty vacuoles near the Golgi complex occured 48 hours after single whole-body X-ray irradiation. Qualitative changes in the ultrastructure of individual types of spermatogonia after individual exposures were similar.

  15. Restoring efficiency of hemopoietic cell transplantation in a mouse lethally irradiated by a total exposure to X rays

    International Nuclear Information System (INIS)

    Doria, Gino

    1959-10-01

    This research thesis reports the study of possibility of treatments (or restoration) of a mouse which has been submitted to a lethal dose of X rays. More particularly, the author compared the restoring efficiency of bone marrow and fetal liver injected in a mouse which had been lethally irradiated by a total exposure to X rays. He also studied the functional status of the hemopoietic graft, and the emergence of the secondary disease in mice which had been as well lethally irradiated and then restored by injection of bone marrow and fetal liver. The author then addressed the influence of the induction of immune tolerance of the host with respect to the donor on the survival of a mouse lethally irradiated and restored by homologue bone marrow [fr

  16. Protocol for X-ray dosimetry and exposure arrangements employed in studies of late somatic effects in mammals

    International Nuclear Information System (INIS)

    Zoetelief, J.; Kogel, A.J. van der; Broerse, J.J.; Scarpa, G.; Dixon-Brown, A.

    1985-01-01

    A number of European laboratories studying the late effects of ionizing radiation in animals have established an effective cooperation within the European Late Effects Project Group (EULEP) since 1970. To facilitate the exchange of biological results several techniques, including quality control of the experimental animals, pathology and dosimetry, have to be standardized. The most important aspects of the procedures for X-irradiation and dosimetry of small animals are summarized. These include recommendations on irradiation conditions, dosimetry methods, characteristics of phantoms and factors affecting X-ray dosimetry. X-irradiation procedures employed by the participating institutes are described and the results of five X-ray dosimetry intercomparisons are reported. The introduction of a common dosimetry protocol has resulted in improvements in exposure arrangements and absolute dosimetry. (author)

  17. Development of a head simulator for exposure dose estimation on patients exposed by odontological X-rays

    International Nuclear Information System (INIS)

    Moura Neto, Francisco N.; Batista, Eutropio V.; Santos, Adriano M.

    2009-01-01

    In the obtaining a odontological radiography, the individual is exposed to te radiation and part of that radiation will be absorbed by his organism. The estimative of absorbed dose can be accomplished through calculations where are considered: the distance from the source to the individual, the energy of the emitted X-ray at the moment of the exposure and the bode region exposed; and as that option does not possess great precision, alternative forms are seek for the quantification such doses. This work proposes the construction of a head simulator to be used in the estimative of absorbed dose in patients, during the accomplishment of the odontological radiographic examinations. As a perspective of work, it is intended to use the phantom to help in the absorbed doses for obtainment of parameters in X-ray odontological devices, contributing of image obtainment with more quality and less radiation dose in the patient

  18. SU-E-I-52: Effect of Various X-Ray Beam Qualities On the Exposure Index

    International Nuclear Information System (INIS)

    Yasumatsu, S; Iwase, K; Shimizu, Y; Tanaka, N; Morishita, J

    2015-01-01

    Purpose: The exposure index (EI) proposed by the International Electrotechnical Commission (IEC) 62494-1 is expected to be utilized as a standard dose index by every manufacturer. The IEC recommended the usage of RQA5 for the EI. However, X-ray beam qualities, particularly in clinical practices, vary depending on the examination objects and exposure conditions, including usage of anti-scatter grids. We investigated the effects of the X-ray beam qualities other than RQA5 on the EI. Methods: The Xray beam qualities of RQA3, 5, 7, and 9 in IEC 61267 Ed. 1.0 were adopted in a computed radiography system. A uniform exposure without objects was performed to measure the exposure indicators (S values) and air kerma (K). The relational equations between the S values and K were derived for the determination of the EI values. The EI values for RQA3, 7, and 9 were compared to those for RQA5 at the fixed S values of 100, 200, 400, and 600. Finally, the half-value layers (HVLs) using four grids (ratio 6:1, 8:1, 10:1, and 12:1) for the RQA5 X-ray were compared to those with RQA3–9. Results: The EI values for RQA3, 7, and 9 were up to 35.3%, 11.8%, and 38.7% higher, respectively, than that for RQA5 at the S value of 600. The HVLs without grids and with various grids for RQA5 were 6.85 mm Al. and in the range of 6.94–7.29 mm Al. (ΔHVL: up to 0.44 mm Al.), respectively. This variation in the HVLs with grids was smaller than that observed for RQA3–9 (ΔHVL: 2.0–7.5 mm Al.). Conclusion: Although the usage of grids may not greatly affect the EI, the X-ray beam quality for the determination of the EI cannot be ignored in the clinical evaluation of the dose index

  19. Effective energies and exposure determinations of two different energy X-ray beams incident on a personnel monitor

    International Nuclear Information System (INIS)

    Okuno, E.; Cruz, M.T. da

    1984-01-01

    The effective energy of one X or gamma ray beam can be determined by means of two thermoluminescent (TL) dosemeters mounted between suitable filters. However, it has been observed that personnel monitors exposed to two different energy ionizing radiations provide different effective energies depeding on the type of TL phosphor used. This fact could be a powerful tool for identifying exposures to radiation with quite different effective energies which are very common in practice. Two types of TL dosemeters were used : pellets of cold pressed natural fluoride and NaCl developed in our own laboratory, and LiF, TLD-100 from Harshaw Chemical Co.. Experimental results obtained with these combined dosemeters after irradiation with different sets of exposures and energy values of ionizing radiations are also presented. (Author) [pt

  20. Effect of in utero exposure to diagnostic doses of X-rays on the growth and behaviour of mouse

    International Nuclear Information System (INIS)

    Prakash Hande, M.; Uma Devi, P.

    1992-01-01

    Intrauterine development, particularly the period of organogenesis is an especially radiosensitive phase in mammals. Teratogenic effect of low dose irradiation has been demonstrated in laboratory animals. Several studies have indicated the vulnerability of the developing human brain to radiation injury and demonstrated changes in postnatal behaviour following intrauterine animal irradiation. However, data are lacking on the comparative response of the different stages of prenatal development to low doses at levels that could result from diagnostic radiation exposure. This study attempts to empirically evaluate the differential response of critical stages in prenatal development of mouse to single low dose exposures to diagnostic X-rays. Data on growth and behaviour are briefly presented. (author). 22 refs., 2 figs., 1 tab

  1. Chronic Low Dose Rate Ionizing Radiation Exposure Induces Premature Senescence in Human Fibroblasts that Correlates with Up Regulation of Proteins Involved in Protection against Oxidative Stress

    Directory of Open Access Journals (Sweden)

    Olga Loseva

    2014-07-01

    Full Text Available The risks of non-cancerous diseases associated with exposure to low doses of radiation are at present not validated by epidemiological data, and pose a great challenge to the scientific community of radiation protection research. Here, we show that premature senescence is induced in human fibroblasts when exposed to chronic low dose rate (LDR exposure (5 or 15 mGy/h of gamma rays from a 137Cs source. Using a proteomic approach we determined differentially expressed proteins in cells after chronic LDR radiation compared to control cells. We identified numerous proteins involved in protection against oxidative stress, suggesting that these pathways protect against premature senescence. In order to further study the role of oxidative stress for radiation induced premature senescence, we also used human fibroblasts, isolated from a patient with a congenital deficiency in glutathione synthetase (GS. We found that these GS deficient cells entered premature senescence after a significantly shorter time of chronic LDR exposure as compared to the GS proficient cells. In conclusion, we show that chronic LDR exposure induces premature senescence in human fibroblasts, and propose that a stress induced increase in reactive oxygen species (ROS is mechanistically involved.

  2. Exposure to ionizing radiation during dental X-rays is not associated with risk of developing meningioma: a meta-analysis based on seven case-control studies.

    Science.gov (United States)

    Xu, Ping; Luo, Hong; Huang, Guang-Lei; Yin, Xin-Hai; Luo, Si-Yang; Song, Ju-Kun

    2015-01-01

    Many observational studies have found that exposure to dental X-rays is associated with the risk of development of meningioma. However, these findings are inconsistent. We conducted a meta-analysis to assess the relationship between exposure to dental X-rays and the risk of development of meningioma. The PubMed and EMBASE databases were searched to identify eligible studies. Summary odds ratio (OR) estimates and 95% confidence intervals (95% CIs) were used to compute the risk of meningioma development according to heterogeneity. Subgroup and sensitivity analyses were performed to further explore the potential heterogeneity. Finally, publication bias was assessed. Seven case-control studies involving 6,174 patients and 19,459 controls were included in the meta-analysis. Neither exposure to dental X-rays nor performance of full-mouth panorex X-rays was associated with an increased risk of development of meningioma (overall: OR, 0.97; 95% CI, 0.70-1.32; dental X-rays: OR, 1.05; 95% CI, 0.89-1.25; panorex X-rays: OR, 1.01; 95% CI, 0.76-1.34). However, exposure to bitewing X-rays was associated with a slightly increased risk of development of meningioma (OR, 1.73; 95% CI, 1.28-2.34). Similar results were obtained in the subgroup and sensitivity analyses. Little evidence of publication bias was observed. Based on the currently limited data, there is no association between exposure to dental X-rays and the risk of development of meningioma. However, these results should be cautiously interpreted because of the heterogeneity among studies. Additional large, high-quality clinical trials are needed to evaluate the association between exposure to dental X-rays and the risk of development of meningioma.

  3. Exposure to ionizing radiation during dental X-rays is not associated with risk of developing meningioma: a meta-analysis based on seven case-control studies.

    Directory of Open Access Journals (Sweden)

    Ping Xu

    Full Text Available Many observational studies have found that exposure to dental X-rays is associated with the risk of development of meningioma. However, these findings are inconsistent. We conducted a meta-analysis to assess the relationship between exposure to dental X-rays and the risk of development of meningioma.The PubMed and EMBASE databases were searched to identify eligible studies. Summary odds ratio (OR estimates and 95% confidence intervals (95% CIs were used to compute the risk of meningioma development according to heterogeneity. Subgroup and sensitivity analyses were performed to further explore the potential heterogeneity. Finally, publication bias was assessed.Seven case-control studies involving 6,174 patients and 19,459 controls were included in the meta-analysis. Neither exposure to dental X-rays nor performance of full-mouth panorex X-rays was associated with an increased risk of development of meningioma (overall: OR, 0.97; 95% CI, 0.70-1.32; dental X-rays: OR, 1.05; 95% CI, 0.89-1.25; panorex X-rays: OR, 1.01; 95% CI, 0.76-1.34. However, exposure to bitewing X-rays was associated with a slightly increased risk of development of meningioma (OR, 1.73; 95% CI, 1.28-2.34. Similar results were obtained in the subgroup and sensitivity analyses. Little evidence of publication bias was observed.Based on the currently limited data, there is no association between exposure to dental X-rays and the risk of development of meningioma. However, these results should be cautiously interpreted because of the heterogeneity among studies. Additional large, high-quality clinical trials are needed to evaluate the association between exposure to dental X-rays and the risk of development of meningioma.

  4. Influence of turmeric on biochemical disorders induced by exposure to gamma- rays or chloropyrifos pesticide on rats

    International Nuclear Information System (INIS)

    Kamal El-Dein, E.M.; Ebrahim, R.M.

    2013-01-01

    Toxicity of Chloropyrifos and gamma-radiation exposure on rats were examined in the presence or absence of Turmeric (200 mg/ kg/ b.wt.). Effects chloropyrifos when administrated orally to rats at a dose 9 mg/ kg b .wt (1/ 4 LD 50) for 7 and 28 days showed increased level of malondialdehyde (MDA) concomitant with depletion in the levels of glutathion (GSH), superoxide dismutase (SOD) and catalase (CAT).gamma- radiation exposure effect on rats was examined in the presence or absence of turmeric . Exposure of rats to gamma-radiation (8 Gy) at a fractionated dose levels (2 Gy/ week for 4 weeks) exhibited an elevated level of MDA and decreased level of GSH, SOD and CAT. Administration of Turmeric to animals which were previously treated with Chloropyrifos or gamma-rays showed an amelioration response to the antioxidant regime. Treatment of rats with Chloropyrifos for 7 and 28 days or gamma- radiation induced an elevated serum transaminases level(ALT and AST),Alkaline phosphatase (ALP) and Acid phosphatase activity (ACP), creatinine concentration, blood urea and uric acid.Also treatment of rats with Chloropyrifos for 7 and 28 days or gamma-radiation induced a decline in the testosterone level associated with alteration in the levels of follicular stimulating hormone (FSH),Iuetinizing hormone (LH) and prolactin (PRL).Results observed due to Chloropyrifos pesticide or radiation-exposure have been ameliorated by turmeric administration. It could be concluded that turmeric might protect from oxidative stress

  5. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure, and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure, and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6, and 15 months) were given five doses (20, 60, 180, 540, and 1620 rad) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rad/day and 25 rad/min). Forty to sixty mice were used in each of the approximately 110 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replication. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the 15-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used

  6. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6 and l5 months) were given five doses (20, 60, 180, 540, and 1620 rads) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rads/day and 25 rads/min). Forty to sixty mice were used in each of the approximately 119 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replicaton. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the l5-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used. It was also concluded that radiaton-induced neoplastic transformaton was significantly greater in mice with a known genetic sensitivity to neoplastic disease than in mammals which do not normally have a significant incidence of tumours. (author)

  7. High Resolution Gamma Ray Spectroscopy at MHz Counting Rates With LaBr3 Scintillators for Fusion Plasma Applications

    Science.gov (United States)

    Nocente, M.; Tardocchi, M.; Olariu, A.; Olariu, S.; Pereira, R. C.; Chugunov, I. N.; Fernandes, A.; Gin, D. B.; Grosso, G.; Kiptily, V. G.; Neto, A.; Shevelev, A. E.; Silva, M.; Sousa, J.; Gorini, G.

    2013-04-01

    High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out at nuclear accelerators, combining a LaBr 3(Ce) detector with dedicated hardware and software solutions based on digitization and off-line analysis. Spectra were measured at counting rates up to 4 MHz, with little or no degradation of the energy resolution, adopting a pile up rejection algorithm. The reported results represent a step forward towards the final goal of high resolution γ-ray spectroscopy measurements on a burning plasma device.

  8. Development of a Watt-level gamma-ray source based on high-repetition-rate inverse Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Mihalcea, D.; Murokh, A.; Piot, P.; Ruan, J.

    2017-07-01

    A high-brilliance (~1022 photon s-1 mm-2 mrad-2 /0.1%) gamma-ray source experiment is currently being planned at Fermilab (Eγ≃1.1 MeV). The source implements a high-repetition-rate inverse Compton scattering by colliding electron bunches formed in a ~300-MeV superconducting linac with a high-intensity laser pulse. This paper describes the design rationale along with some of technical challenges associated to producing high-repetition-rate collision. The expected performances of the gamma-ray source are also presented.

  9. Detectability of changes in cosmic-ray counting rate measured with the Liulin detector

    International Nuclear Information System (INIS)

    Malusek, A.; Kubancak, J.; Ambrozova, I.

    2011-05-01

    Experimental data are needed to improve and validate models predicting the dynamics of solar particle events because the mechanisms of processes leading to the acceleration of solar energetic particles are not yet fully understood. The aim of this work was to examine whether the spectrometer of deposited energy, Liulin, positioned at the Lomnický štít mountain observatory can collect such data. Decision thresholds and detection limits for the increase or decrease in the average number of particles detected by Liulin were determined for a period in February 2011. The changes in counts corresponding to the decision thresholds and detection limits relative to the average number of detected particles were about 17% and 33%, respectively. The Forbush decrease with a maximum change of about 6.8%, which started on February 18, was detectable neither during the 10-minute acquisition time nor during any other, longer period. Statistical analysis showed that an acquisition time about 7 hours would be needed to detect a 5% decrease. As this time was shorter than the duration of the Forbush decrease (about 56 hours), we theorize that the current placement of the Liulin detector inside a living room shielded by a thick concrete ceiling may have had an adverse impact on the detectability of the the cosmic ray counting rate decrease. To test this hypothesis, we recommend positioning the Liulin detector outside the main observatory building.. (author)

  10. Estimating detection rates for the LIGO-Virgo search for gravitational-wave burst counterparts to gamma-ray bursts using inferred local GRB rates

    International Nuclear Information System (INIS)

    Leonor, I; Frey, R; Sutton, P J; Jones, G; Marka, S; Marka, Z

    2009-01-01

    One of the ongoing searches performed using the LIGO-Virgo network of gravitational-wave interferometers is the search for gravitational-wave burst (GWB) counterparts to gamma-ray bursts (GRBs). This type of analysis makes use of GRB time and position information from gamma-ray satellite detectors to trigger the GWB search, and the GWB detection rates possible for such an analysis thus strongly depend on the GRB detection efficiencies of the satellite detectors. Using local GRB rate densities inferred from observations which are found in the science literature, we calculate estimates of the GWB detection rates for different configurations of the LIGO-Virgo network for this type of analysis.

  11. The White Dwarf Mass and the Accretion Rate of Recurrent Novae: An X-ray Perspective

    Science.gov (United States)

    Mukai, Koji; Sokoloski, Jennifer L.; Nelson, Thomas; Luna, Gerardo J. M.

    2011-01-01

    We present recent results of quiescent X-ray observations of recurrent novae (RNe) and related objects. Several RNe are luminous hard X-ray sources in quiescence, consistent with accretion onto a near Chandrasekhar mass white dwarf. Detection of similar hard X-ray emissions in old novae and other cataclysmic variables may lead to identification of additional RN candidates. On the other hand, other RNe are found to be comparatively hard X-ray faint. We present several scenarios that may explain this dichotomy, which should be explored further.

  12. Time Course of Heart Rate Variability Response to PM2.5 Exposure from Secondhand Smoke.

    Directory of Open Access Journals (Sweden)

    Jennifer L Garza

    Full Text Available Exposure to secondhand smoke (SHS has been associated with decreased heart rate variability (HRV. However, the time course of this association is unclear. Therefore, the objective of this study was to investigate the association between 15-240 minute SHS-related fine particulate matter (PM2.5 moving averages and indices of HRV.With a panel study design, we used personal monitors to continuously measure PM2.5 and HRV of 35 participants who were exposed to SHS for approximately 6 hours.We observed negative, significant associations between 5-minute HRV indices and 15 minute PM2.5 moving averages and 240 minute PM2.5 moving averages: there was a significant (p<0.01 7.5% decrease in the 5-minute square root of the mean squared differences of successive normal heart beats associated with (RMSSD, and a significant (p<0.01 14.7% decrease in the 5-minute high frequency (HF power associated with the 15 minute PM2.5 moving averages; there was also a significant (p<0.01 46.9% decrease in the 5-minute RMSSD, and a significant (p<0.01 77.7% decrease in the 5-minute high frequency (HF power associated with the 240 minute PM2.5 moving averages.Our findings that exposure to SHS related PM2.5 was associated with HRV support the hypothesis that SHS can affect the cardiovascular system. The negative associations reported between short and longer term PM2.5 and HRV indicate adverse effects of SHS on the cardiovascular system.

  13. Symbolic Analysis of Heart Rate Variability During Exposure to Musical Auditory Stimulation.

    Science.gov (United States)

    Vanderlei, Franciele Marques; de Abreu, Luiz Carlos; Garner, David Matthew; Valenti, Vitor Engrácia

    2016-01-01

    In recent years, the application of nonlinear methods for analysis of heart rate variability (HRV) has increased. However, studies on the influence of music on cardiac autonomic modulation in those circumstances are rare. The research team aimed to evaluate the acute effects on HRV of selected auditory stimulation by 2 musical styles, measuring the results using nonlinear methods of analysis: Shannon entropy, symbolic analysis, and correlation-dimension analysis. Prospective control study in which the volunteers were exposed to music and variables were compared between control (no auditory stimulation) and during exposure to music. All procedures were performed in a sound-proofed room at the Faculty of Science and Technology at São Paulo State University (UNESP), São Paulo, Brazil. Participants were 22 healthy female students, aged between 18 and 30 y. Prior to the actual intervention, the participants remained at rest for 20 min, and then they were exposed to one of the selected types of music, either classical baroque (64-84 dB) or heavy-metal (75-84 dB). Each musical session lasted a total of 5 min and 15 s. At a point occurring up to 1 wk after that day, the participants listened to the second type of music. The 2 types of music were delivered in a random sequence that depended on the group to which the participant was assigned. The study analyzed the following HRV indices through Shannon entropy; symbolic analysis-0V%, 1V%, 2LV%, and 2ULV%; and correlation-dimension analysis. During exposure to auditory stimulation by heavy-metal or classical baroque music, the study established no statistically significant variations regarding the indices for the Shannon entropy; the symbolic analysis-0V%, 1V%, and 2ULV%; and the correlation-dimension analysis. However, during heavy-metal music, the 2LV% index in the symbolic analysis was reduced compared with the controls. Auditory stimulation with the heavy-metal music reduced the parasympathetic modulation of HRV

  14. Occupational exposure and risks associated with the X-ray and gamma ray scanners used for destination inspection at the port of Tema, Ghana

    International Nuclear Information System (INIS)

    Gbormittah, S.V.

    2010-01-01

    The x-ray linear accelerator scanner with average energy of 5 MeV operated by the Gateway Services Limited (GSL) and the Cobalt-60 gamma ray scanner with average energy of 1.25 MeV operated by the Ghana Customs Inspection Company Limited (GCIC) have been in use for destination inspection at the Port of Tema for the past ten (10) and six (6) years respectively. For radiation protection purposes, there is the need to assess the risk of exposure to ensure that Staff are not unduly overexposed to minimize the likelihood of adverse radiation effects. The prime objective of this research was to compare the risks from exposure, working conditions and safety culture of the two facilities in order to determine the facility that gives higher levels of exposure to the workers. Data was collected by means of questionnaires and measurements at the two facilities for a period of eight (8) weeks. Personal monitoring data for the occupationally exposed workers of the two facilities for a period sixty-one (61) months were obtained from the Personal Monitoring Laboratory of the Radiation Protection Board; these data were used for mean annual dose, mean annual collective dose and risks assessments for Staff of the two facilities. Ambient dose measurements were carried out with a calibrated Thermo Electron Micro Sievert Doserate survey meter and LiF TLD-100 dosimeters at selected points in the two facilities were 1.16 mSv/a and 1.41 mSv/a respectively. The mean annual effective doses estimated for the collective doses were 8.1man-Sv and 21.15 man-Sv for Staff of GSL and GCIC respectively. Assessment of risks using the ICRP 103 and 60 risk assessment models indicated that Staff of GSL and GCIC had a 0.14% and 0.17% risk of developing fatal cancer respectively. Staff of GSL had a 0.02% risk of passing on adverse hereditary traits to offsprings born after exposure while Staff of GCIC had a hereditary risk of 0.03% of passing on adverse hereditary traits to offsprings born after exposure

  15. Reducing exposure of X-ray radiodiagnosis personnel with use of apron

    International Nuclear Information System (INIS)

    Snobr, J.

    1988-01-01

    Experimental results are presented showing dose reduction in X-ray irradiation thanks to protective aprons from lead-containing rubber. The values were used to calculate a reduction in the effective dose equivalent while using the protective apron for isotropic irradiation and for frontal irradiation. A method for optimizing the lead equivalent of the protective apron is suggested. (author). 7 tabs., 6 refs

  16. X-ray exposure hazards for physicians performing ablation procedures and device implantation

    DEFF Research Database (Denmark)

    Marinskis, Germanas; Bongiorni, Maria Grazia; Dagres, Nikolaos

    2013-01-01

    The purpose of the survey was to evaluate physician's and authorities policies and clinical practices when using occupational X-ray during ablation procedures and device implantation. This survey shows infrequent use of lead gloves, radiation absorbing pads, and lead glass cabins, but increasing ...

  17. Steep Hard-X-ray Spectra Indicate Extremely High Accretion Rates in Weak Emission-Line Quasars

    Science.gov (United States)

    Marlar, Andrea; Shemmer, Ohad; Anderson, Scott F.; Brandt, W. Niel; Diamond-Stanic, Aleksandar M.; Fan, Xiaohui; Luo, Bin; Plotkin, Richard; Richards, Gordon T.; Schneider, Donald P.; Wu, Jianfeng

    2018-06-01

    We present XMM-Newton imaging spectroscopy of ten weak emission-line quasars (WLQs) at 0.928 ≤ z ≤ 3.767, six of which are radio quiet and four which are radio intermediate. The new X-ray data enabled us to measure the hard-X-ray power-law photon index (Γ) in each source with relatively high accuracy. These measurements allowed us to confirm previous reports that WLQs have steeper X-ray spectra, therefore indicating higher accretion rates with respect to "typical" quasars. A comparison between the Γ values of our radio-quiet WLQs and those of a carefully-selected, uniform sample of 84 quasars shows that the first are significantly higher, at the ≥ 3σ level. Collectively, the four radio-intermediate WLQs have lower Γ values with respect to the six radio-quiet WLQs, as may be expected if the spectra of the first group are contaminated by X-ray emission from a jet. These results suggest that, in the absence of significant jet emission along our line of sight, WLQs constitute the extreme high end of the accretion rate distribution in quasars. We detect soft excess emission in our lowest-redshift radio-quiet WLQ, in agreement with previous findings suggesting that the prominence of this feature is associated with a high accretion rate. We have not detected signatures of Compton reflection, Fe Kα lines, or strong variability between two X-ray epochs in any of our WLQs.

  18. Relative biological effectiveness (RBE) of fission neutrons and gamma rays at occupational exposure levels: Volume 1, Studies on the genetic effects in mice of 60 equal once-weekly exposures to fission neutrons and gamma rays

    International Nuclear Information System (INIS)

    Grahn, D.; Carnes, B.A.

    1987-10-01

    The relative biological effectiveness (RBE) values for low doses of fission neutrons compared to 60 Co gamma rays were determined with four separate assessments of genetic damage induced in young hybrid male mice. Both radiations were delivered at low dose levels over about one-half the adult lifetime as 60 once-weekly exposures. Genetic damage assessed included both transient and residual injury. The latter is more critical, as residual genetic injury can be transmitted to subsequent generations long after the radiation exposures have ceased. Assays were performed periodically during the 60-week exposure period and at 10 or more weeks after the irradiations had terminated. RBE values, with few exceptions, ranged between 5 and 15 for transient injury and between 25 and 50 for different types of residual genetic injury. The most important form of residual genetic damage in this study was the balanced reciprocal chromosome translocation. These translocations continue to be transmitted throughout reproductive life and can lead to reduced fertility and increased prenatal mortality. The best estimate of the RBE value for translocations was 45 +- 10. Implications and recommendations with regard to the neutron quality factor will be presented conjointly with the findings from the data obtained in this same project on life shortening and on the risks of incidence or death from neoplastic disease. 64 refs., 23 tabs

  19. DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2013-01-01

    Full Text Available We introduce a system of Diagnostic Reference Levels (DRLs for patients medical exposure for national health care practice implementation. DRLs are an effective way of the patient radiation protection through the optimization of the medical exposure. The paper discusses and compares different methods of determining the DRLs based on measured and/or calculated quantities of patient’s dose: dose area product (DAP, entrance surface dose (ESD and an effective dose. Distributions of different dose quantities in different Saint-Petersburg clinics are shown on the example of chest PA examinations. The results are compared with the data from other sources. Regional DRLs for Saint-Petersburg are proposed.

  20. Simulation of short-term fluctuations in gamma exposure rate due to radioactive cloud released from nuclear power plant

    International Nuclear Information System (INIS)

    Ichikawa, Yoichi; Shikata, Hiroshi; Ishida, Kenji; Ohba, Tachimori.

    1981-01-01

    The measured γ-exposure rate around nuclear power plants is due mainly to natural causes and radioactive clouds emitted from the plants. An exposure calculation method based on puff model has been already proposed to identify the plant contributions and to estimate values in response to short-term fluctuations of meteorological condition and the release rate. However, the calculation method by this model consumes a lot of computer time, since the calculation requires a three-dimensional integration of the distribution of the concentration from each puff. Hence, we propose a simplified method using approximate polynominal equations and interpolations. The computer time needed for the calculation with the simplified method is reduced to 1/30 of that required by the previous method. The calculation results by simplified method are compared with those by the previous method and with the measured exposure rate less natural background. The results of two different methods are in good agreement. The calculated exposure rate is within the range from half to twice as much as the measured exposure rate less background. (author)

  1. Mutation induction in cultured human cells after low-dose and low-dose-rate γ-ray irradiation. Detection by LOH analysis

    International Nuclear Information System (INIS)

    Umebayashi, Yukihiro; Iwaki, Masaya; Yatagai, Fumio; Honma, Masamitsu; Suzuki, Masao; Suzuki, Hiromi; Shimazu, Toru; Ishioka, Noriaki

    2007-01-01

    To study the genetic effects of low-doses and low-dose-rate ionizing radiation (IR), human lymphoblastoid TK6 cells were exposed to 30 mGy of γ-rays at a dose-rate of 1.2 mGy/hr. The frequency of early mutations (EMs) in the thymidine kinase (TK) gene locus was determined to be 1.7 x 10 -6 , or 1.9-fold higher than the level seen in unirradiated controls. These mutations were analyzed with a loss of heterozygosity (LOH) detection system, a methodology which has been shown to be sensitive to the effects of radiation. Among the 15 EMs observed after IR exposure, 8 were small interstitial-deletion events restricted to the TK gene locus. However, this specific type of event was not found in unirradiated controls. Although these results were observed under the limited conditions, they strongly suggest that the LOH detection system can be used for estimating the genetic effects of a low-dose IR exposure delivered at a low-dose-rate. (author)

  2. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo; Kamei, Tetsuya; Koga, Sukehiko

    1998-01-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  3. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo [Fujita Health Univ., Toyoake, Aichi (Japan). School of Health Science; Kamei, Tetsuya; Koga, Sukehiko

    1998-12-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  4. X-ray film reject rate analysis at eight selected government hospitals ...

    African Journals Online (AJOL)

    admin

    Objective: The purpose of this research was to identify the main causes of film faults as well as the pattern and magnitude of film ... ensure satisfactory performance of radiographic x-ray equipment on a day-to-day basis. Quality assurance programs are primarily concerned with maintaining of X- ray imaging equipment at the ...

  5. Seasonal variations of indoor microbial exposures and their relation to temperature, relative humidity, and air exchange rate.

    Science.gov (United States)

    Frankel, Mika; Bekö, Gabriel; Timm, Michael; Gustavsen, Sine; Hansen, Erik Wind; Madsen, Anne Mette

    2012-12-01

    Indoor microbial exposure has been related to adverse pulmonary health effects. Exposure assessment is not standardized, and various factors may affect the measured exposure. The aim of this study was to investigate the seasonal variation of selected microbial exposures and their associations with temperature, relative humidity, and air exchange rates in Danish homes. Airborne inhalable dust was sampled in five Danish homes throughout the four seasons of 1 year (indoors, n = 127; outdoors, n = 37). Measurements included culturable fungi and bacteria, endotoxin, N-acetyl-beta-d-glucosaminidase, total inflammatory potential, particles (0.75 to 15 μm), temperature, relative humidity, and air exchange rates. Significant seasonal variation was found for all indoor microbial exposures, excluding endotoxin. Indoor fungi peaked in summer (median, 235 CFU/m(3)) and were lowest in winter (median, 26 CFU/m(3)). Indoor bacteria peaked in spring (median, 2,165 CFU/m(3)) and were lowest in summer (median, 240 CFU/m(3)). Concentrations of fungi were predominately higher outdoors than indoors, whereas bacteria, endotoxin, and inhalable dust concentrations were highest indoors. Bacteria and endotoxin correlated with the mass of inhalable dust and number of particles. Temperature and air exchange rates were positively associated with fungi and N-acetyl-beta-d-glucosaminidase and negatively with bacteria and the total inflammatory potential. Although temperature, relative humidity, and air exchange rates were significantly associated with several indoor microbial exposures, they could not fully explain the observed seasonal variations when tested in a mixed statistical model. In conclusion, the season significantly affects indoor microbial exposures, which are influenced by temperature, relative humidity, and air exchange rates.

  6. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schirmer, A. [Arbeitsgruppe Aufklarung der Arbeitsplatzverhaltnisse Radar, Wehrbereichsverwaltung Nord, Bundeswehr, Munster (Germany)

    2006-07-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H{sup *}(10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  7. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    International Nuclear Information System (INIS)

    Schirmer, A.

    2006-01-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H * (10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  8. Effects of Moxa (Folium Artemisiae argyi Smoke Exposure on Heart Rate and Heart Rate Variability in Healthy Young Adults: A Randomized, Controlled Human Study

    Directory of Open Access Journals (Sweden)

    Yingxue Cui

    2013-01-01

    Full Text Available Objective. To determine the effects of the moxa smoke on human heart rate (HR and heart rate variability (HRV. Methods. Fifty-five healthy young adults were randomly divided into experimental (n=28 and control (n=27 groups. Experimental subjects were exposed to moxa smoke (2.5 ± 0.5 mg/m3 twice for 25 minutes in one week. ECG monitoring was performed before, during, and after exposure. Control subjects were exposed to normal indoor air in a similar environment and similarly monitored. Followup was performed the following week. Short-term (5 min HRV parameters were analyzed with HRV analysis software. SPSS software was used for statistical analysis. Results. During and after the first exposure, comparison of percentage changes or changes in all parameters between groups showed no significant differences. During the second exposure, percentage decrease in HR, percentage increases in lnTP, lnHF, lnLF, and RMSSD, and increase in PNN50 were significantly greater in the experimental group than in control. Conclusion. No significant adverse HRV effects were associated with this clinically routine 25-minute exposure to moxa smoke, and the data suggests that short-term exposure to moxa smoke might have positive regulating effects on human autonomic function. Further studies are warranted to confirm these findings.

  9. Formation Rates of Black Hole Accretion Disk Gamma-Ray Bursts

    International Nuclear Information System (INIS)

    Fryer, Chris L.; Woosley, S. E.; Hartmann, Dieter H.

    1999-01-01

    The cosmological origin of at least an appreciable fraction of classical gamma-ray bursts (GRBs) is now supported by redshift measurements for a half-dozen faint host galaxies. Still, the nature of the central engine (or engines) that provide the burst energy remains unclear. While many models have been proposed, those currently favored are all based upon the formation of and/or rapid accretion into stellar-mass black holes. Here we discuss a variety of such scenarios and estimate the probability of each. Population synthesis calculations are carried out using a Monte Carlo approach in which the many uncertain parameters intrinsic to such calculations are varied. We estimate the event rate for each class of model as well as the propagation distances for those having significant delay between formation and burst production, i.e., double neutron star (DNS) mergers and black hole-neutron star (BH/NS) mergers. One conclusion is a 1-2 order of magnitude decrease in the rate of DNS and BH/NS mergers compared to that previously calculated using invalid assumptions about common envelope evolution. Other major uncertainties in the event rates and propagation distances include the history of star formation in the universe, the masses of the galaxies in which merging compact objects are born, and the radii of the hydrogen-stripped cores of massive stars. For reasonable assumptions regarding each, we calculate a daily event rate in the universe for (1) merging neutron stars: ∼100 day-1; (2) neutron star-black hole mergers: ∼450 day-1; (3) collapsars: ∼104 day-1; (4) helium star black hole mergers: ∼1000 day-1; and (5) white dwarf-black hole mergers: ∼20 day-1. The range of uncertainty in these numbers, however, is very large, typically 2-3 orders of magnitude. These rates must additionally be multiplied by any relevant beaming factor (f Ω <1) and sampling fraction (if the entire universal set of models is not being observed). Depending upon the mass of the host

  10. A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

    Directory of Open Access Journals (Sweden)

    Jai Wan Cho

    2014-01-01

    Full Text Available We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

  11. A comparison of calculated and measured background noise rates in hard X-ray telescopes at balloon altitude

    Science.gov (United States)

    Dean, A. J.; Dipper, N. A.; Lewis, R. A.; Perotti, F.

    1985-01-01

    An actively shielded hard X-ray astronomical telescope has been flown on stratospheric balloons. An attempt is made to compare the measured spectral distribution of the background noise counting rates over the energy loss range 20-300 keV with the contributions estimated from a series of Monte Carlo and other computations. The relative contributions of individual particle interactions are assessed.

  12. Interpretation of soil-type maps of forestry in terms of terrestrial gamma-ray dose rate

    International Nuclear Information System (INIS)

    Kopp, D.; Hannemann, M.

    1984-01-01

    Measurements have been performed in the lowlands of the G.D.R. to determine the activity concentration of 40 K, 226 Ra and 232 Th in soil as well as the terrestrial γ-ray dose rate at the soil surface and 1 m above. The results demonstrate that the dose rate due to terrestrial radiation can be assessed by means of forest site maps indicating the potassium content of the various soils. Two examples were presented to explain the approach. (author)

  13. Changes in respiration rates and biomass attributes of epilithon due to extended exposure to zinc

    International Nuclear Information System (INIS)

    Colwell, F.S.

    1986-01-01

    The purpose of this research was to determine the influence of extended dosing of zinc on the carbon cycling and biomass characteristics of freshwater epilithon. Experiments were conducted in artificial streams continuously dosed with 0.00, 0.05, or 1.00 mg Zn liter -1 for 20 to 30 days during summer and fall, 1984 and 1985. Repeated measurement of epilithon structure and function included estimates of 14 C-glucose respiration, 14 C-glutamate respiration, O 2 and CO 2 flux rates, ash-free dry weight (AFDW), protein, carbohydrate, and algal pigment concentrations, and total and zinc-tolerant colony forming units. An increase in epilithic glucose respiration per unit biomass consistently occurred 5 to 10 days after dosing with 1.0 mg Zn liter -1 was started. At the same time significantly lower epilithon biomass occurred in the high dosed streams relative to controls in 3 out of 4 studies. Although algal pigment concentrations were lowest in the high dose streams at the midpoint of the studies, the chlorophyll a-to-pheophytin a ratio remained high, indicating that the minimal algal population was not senescing in situ. After 30 days, the epilithon dosed with 1.0 mg Zn liter -1 had higher AFDW, protein, and carbohydrate concentrations than the other treatments. The development of unique epilithon communities that are acclimated to prolonged zinc exposure is evident in the eventual recolonization of the artificial surfaces, glucose respiration rates that are comparable to controls, and presence of zinc-tolerant heterotrophs

  14. Readiness evaluation report -- High-exposure rate hardware removal resumption of activities

    International Nuclear Information System (INIS)

    Volkman, C.L.

    1996-11-01

    In August 1996, N Basin Project Management proactively ceased activities in the N Basin after noting several radiological control anomalies occurring during the performance of the high exposure rate hardware removal activity. The HERH is one of several activities that will be accomplished to complete deactivation of N Basin. Three project critiques were performed to identify causes and several corrective actions were identified. To ensure the true causes of the events were identified the N Basin Project Manager requested that a root cause analysis be performed for the events covered by the three critiques. The intent was to identify recurring events and evaluate the effectiveness of corrective action implementation. These three review elements were used by the project to develop a corrective action plan (CAP) which consisted of both project unique and programmatic items. The N Basin Project is using this BHI Readiness Evaluation (RE) process as a mechanism to independently verify that corrective actions identified from the CAP have been completed and that no changes have been made during the stand down that affect the resumption of the HERH activities. A readiness evaluation (RE) plan (Attachment 3) was prepared. The completed Readiness Evaluation Records which documents the results of the team member evaluations are in attachment 1. The independent readiness evaluation team identified 5 deficiencies of which two are post startup and three are pre startup. All deficiencies are in the area of training. These findings are explained in detail in Attachment 2

  15. Evaluating terrain based criteria for snow avalanche exposure ratings using GIS

    Science.gov (United States)

    Delparte, Donna; Jamieson, Bruce; Waters, Nigel

    2010-05-01

    Snow avalanche terrain in backcountry regions of Canada is increasingly being assessed based upon the Avalanche Terrain Exposure Scale (ATES). ATES is a terrain based classification introduced in 2004 by Parks Canada to identify "simple", "challenging" and "complex" backcountry areas. The ATES rating system has been applied to well over 200 backcountry routes, has been used in guidebooks, trailhead signs and maps and is part of the trip planning component of the AVALUATOR™, a simple decision-support tool for backcountry users. Geographic Information Systems (GIS) offers a means to model and visualize terrain based criteria through the use of digital elevation model (DEM) and land cover data. Primary topographic variables such as slope, aspect and curvature are easily derived from a DEM and are compatible with the equivalent evaluation criteria in ATES. Other components of the ATES classification are difficult to extract from a DEM as they are not strictly terrain based. An overview is provided of the terrain variables that can be generated from DEM and land cover data; criteria from ATES which are not clearly terrain based are identified for further study or revision. The second component of this investigation was the development of an algorithm for inputting suitable ATES criteria into a GIS, thereby mimicking the process avalanche experts use when applying the ATES classification to snow avalanche terrain. GIS based classifications were compared to existing expert assessments for validity. The advantage of automating the ATES classification process through GIS is to assist avalanche experts with categorizing and mapping remote backcountry terrain.

  16. High strain rate mechanical response of buttress-grooved tensile specimens which have undergone environmental exposure

    International Nuclear Information System (INIS)

    Weirick, L.J.

    1976-07-01

    The purpose of the corrosion compatibility program was to identify the effect of corrosion on the mechanical performance of the buttress-grooved section of the 105-mm penetrator, a section which must sustain a load during launch. It is important that the environment not deteriorate the mechanical integrity of these grooves during long-term storage. Both coated and uncoated test specimens which simulate both geometrical shape and residual stress patterns were exposed to corrosive environments of moist air, distilled water, and salt water. Some of these tests also incorporated the galvanic coupling caused by the aluminum sabot. After exposure to the corrosive environments, the specimens were pulled on a high strain rate tensile machine which simulated launch conditions. Results show that the galvanic coupling due to the aluminum sabot caused no deterioration of mechanical properties. Results do indicate that the coating applied caused a significant reduction in the fracture load. There was a dichotomy in the results as affected by the environment. Uncoated test specimens showed no change in fracture load with increasing severity of corrosion environment, whereas the coated specimens indicated a trend of decreasing load-bearing ability with increasing corrosion

  17. Association of soil arsenic and nickel exposure with cancer mortality rates, a town-scale ecological study in Suzhou, China.

    Science.gov (United States)

    Chen, Kai; Liao, Qi Lin; Ma, Zong Wei; Jin, Yang; Hua, Ming; Bi, Jun; Huang, Lei

    2015-04-01

    Heavy metals and arsenic are well-known carcinogens. However, few studies have examined whether soil heavy metals and arsenic concentrations associate with cancer in the general population. In this ecological study, we aimed to evaluate the association of heavy metals and arsenic in soil with cancer mortality rates during 2005-2010 in Suzhou, China, after controlling for education and smoking prevalence. In 2005, a total of 1683 soil samples with a sampling density of one sample every 4 km(2) were analyzed. Generalized linear model with a quasi-Poisson regression was applied to evaluate the association between town-scale cancer mortality rates and soil heavy metal concentrations. Results showed that soil arsenic exposure had a significant relationship with colon, gastric, kidney, lung, and nasopharyngeal cancer mortality rates and soil nickel exposure was significantly associated with liver and lung cancer. The associations of soil arsenic and nickel exposure with colon, gastric, kidney, and liver cancer in male were higher than those in female. The observed associations of soil arsenic and nickel with cancer mortality rates were less sensitive to alternative exposure metrics. Our findings would contribute to the understanding of the carcinogenic effect of soil arsenic and nickel exposure in general population.

  18. Study of the argyrophil structures of thymus connective tissue after exposure to X-rays

    International Nuclear Information System (INIS)

    Beletskij, V.K.; Beletskaya, L.V.; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Ehpidemiologii i Mikrobiologii)

    1980-01-01

    Studied are argyrophil structures of thymus connective tissue - histiocytes (appendiculate macrophages) and reticuline fibers after the bulk of lymphoid cells has migrated from the organ due to irradiation of animals with X-rays. 10 intact and 16 experimental guinea pigs subjected to the whole-body irradiation with X-rays in the dose of 1000-3000 rad have been used for investigations. It is shown that argyrophil stroma elements of thymus connective tissue, histiocytes and reticular cells, are rather resistant to X-rays and preserve their argyrophily property in the irradiation with high doses, as well as the epithelial cells of the organ. Paraplastic structures in irradiated animals are expressed more completely being demasked as a result of lymphocyte migration and death. The expressed hypertrophy and proliferation of reticular cells and appendiculate macrophages are probably the response to the alternative process in the organ tissues caused by irradiation. A close structural connection of reticular and epithelial tissues on the territory of both layers of thymus sections is noted

  19. Aging simulation of the tailings from Stava fluorite extraction by exposure to gamma rays

    Directory of Open Access Journals (Sweden)

    Gianluca Bella

    Full Text Available Abstract Tailings storage facilities are disposal systems for storing the waste products of the mining industry consisting of a slurry mixture made of soil, rock and water that remain after the mineral values have been removed from the patent ore. Tailings dams are supposed to last forever, so after their deposition, tailings can experience aging processes with physical and chemical changes depending on the interactions between local conditions and source mineralogy. The consequences of these aging processes are increased interlocking of particles and oxidation processes, sometimes making previously safely held contaminants available and mobile. Among the long-term aging processes, the natural ionizing radiation (from radioactive isotopes of the soils, cosmic rays, and also ultraviolet rays from the sun can be considered, as proposed in the current research. Furthermore, in many countries, tailings are beginning to be re-used as backfill, landscaping material or feedstock for cement and concrete. So if any, the long-term physical and chemical modifications could affect the hydraulic and mechanical behaviour of tailings with relevant economic consequences. For these reasons, wet and dry silty samples of tailings spilled out after the failure of the Stava tailings dam (Trentino Alto Adige, Italy were exposed to gamma rays, as an accelerated aging technique to simulate the natural ionizing radiation, and then characterized. The modifications on physical and chemical properties were observed and, despite certain chemical stability, some physical changes were observed, particularly in terms of size particle distribution, inner porosity of the particles and specific surface.

  20. Aging simulation of the tailings from Stava fluorite extraction by exposure to gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Bella, Gianluca; Barbero, Monica; Barpi, Fabrizio, E-mail: gianluca.bella@polito.it, E-mail: monica.barbero@polito.it, E-mail: fabrizio.barpi@polito.it [Politecnico di Torino - DISEG (Italy); Lameiras, Fernando Soares, E-mail: fsl@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Espósito, Terezinha de Jesus, E-mail: esposito@etg.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Transporte e Engenharia Geotécnica

    2017-10-15

    Tailings storage facilities are disposal systems for storing the waste products of the mining industry consisting of a slurry mixture made of soil, rock and water that remain after the mineral values have been removed from the patent ore. Tailings dams are supposed to last forever, so after their deposition, tailings can experience aging processes with physical and chemical changes depending on the interactions between local conditions and source mineralogy. The consequences of these aging processes are increased interlocking of particles and oxidation processes, sometimes making previously safely held contaminants available and mobile. Among the long-term aging processes, the natural ionizing radiation (from radioactive isotopes of the soils, cosmic rays, and also ultraviolet rays from the sun) can be considered, as proposed in the current research. Furthermore, in many countries, tailings are beginning to be re-used as backfill, landscaping material or feedstock for cement and concrete. So if any, the long-term physical and chemical modifications could affect the hydraulic and mechanical behaviour of tailings with relevant economic consequences. For these reasons, wet and dry silty samples of tailings spilled out after the failure of the Stava tailings dam (Trentino Alto Adige, Italy) were exposed to gamma rays, as an accelerated aging technique to simulate the natural ionizing radiation, and then characterized. The modifications on physical and chemical properties were observed and, despite certain chemical stability, some physical changes were observed, particularly in terms of size particle distribution, inner porosity of the particles and specific surface. (author)

  1. Secondhand tobacco smoke exposure and heart rate variability and inflammation among non-smoking construction workers: a repeated measures study.

    Science.gov (United States)

    Zhang, Jinming; Fang, Shona C; Mittleman, Murray A; Christiani, David C; Cavallari, Jennifer M

    2013-10-02

    Although it has been well recognized that exposure to secondhand tobacco smoke (SHS) is associated with cardiovascular mortality, the mechanisms and time course by which SHS exposure may lead to cardiovascular effects are still being explored. Non-smoking workers were recruited from a local union and monitored inside a union hall while exposed to SHS over approximately 6 hours. Participants were fitted with a continuous electrocardiographic monitor upon enrollment which was removed at the end of a 24-hr monitoring period. A repeated measures study design was used where resting ECGs and blood samples were taken from individuals before SHS exposure (baseline), immediately following SHS exposure (post) and the morning following SHS exposure (next-morning).Inflammatory markers, including high sensitivity C-reactive protein (CRP) and white blood cell count (WBC) were analyzed. Heart rate variability (HRV) was analyzed from the ECG recordings in time (SDNN, rMSSD) and frequency (LF, HF) domain parameters over 5-minute periods. SHS exposure was quantified using a personal fine particulate matter (PM2.5) monitor.Linear mixed effects regression models were used to examine within-person changes in inflammatory and HRV parameters across the 3 time periods. Exposure-response relationships with PM2.5 were examined using mixed effects models. All models were adjusted for age, BMI and circadian variation. A total of 32 male non-smokers were monitored between June 2010 and June 2012. The mean PM2.5 from SHS exposure was 132 μg/m3. Immediately following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with declines in HRV (7.8% [standard error (SE) =3%] SDNN, 8.0% (SE = 3.9%) rMSSD, 17.2% (SE = 6.3%) LF, 29.0% (SE = 10.1%) HF) and increases in WBC count 0.42 (SE = 0.14) k/μl. Eighteen hours following SHS exposure, a 100 μg/m3 increase in PM2.5 was associated with 24.2% higher CRP levels. Our study suggest that short-term SHS exposure is associated

  2. Development of an algorithm for X-ray exposures using the Panasonic UD-802A thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    McKittrick, Leo; Currivan, Lorraine; Pollard, David; Nicholls, Colyn; Romero, A.M.; Palethorpe, Jeffrey

    2008-01-01

    Full text: As part of its continuous quality improvement the Dosimetry Service of the Radiological Protection Institute of Ireland (RPII) in conjunction with Panasonic Industrial Europe (UK) has investigated further the use of the standard Panasonic algorithm for X-ray exposures using the Panasonic UD-802A TL dosemeter. Originally developed to satisfy the obsolete standard ANSI 13.11-1983, the standard Panasonic dose algorithm has undergone several revisions such as HPS N13.11-2001. This paper presents a dose algorithm that can be used to correct the dose response at low energies such as X-ray radiation using a four element TL dosemeter due to the behaviour of two different independent phosphors. A series of irradiations with a range of energies using N-20 up to Co-60 were carried out with our particular interest being in responses to X-ray irradiations. Irradiations were performed at: RRPPS, University Hospital Birmingham NHS Foundation Trust, U.K.; HPA, U.K. and CIEMAT, Madrid, Spain. Different irradiation conditions were employed which included: X-ray from narrow and wide spectra as described by ISO 4037-1 (1996), and ISO water slab phantom and PMMA slab phantom respectively. Using the UD-802A TLD and UD-854AT hanger combination, the response data from the series of irradiations was utilised to validate and if necessary, modify the photon/beta branches of the algorithm to: 1. Best estimate Hp(10) and Hp(0.07); 2. Provide information on irradiation energies; 3. Verification by performance tests. This work further advances the algorithm developed at CIEMAT whereby a best-fit, polynomial trend is used with the dose response variations between the independent phosphors. (author)

  3. ERX: a software for editing files containing X-ray spectra to be used in exposure computational models

    International Nuclear Information System (INIS)

    Cabral, Manuela O.M.; Vieira, Jose W.; Silva, Alysson G.; Leal Neto, Viriato; Oliveira, Alex C.H.; Lima, Fernando R.A.

    2011-01-01

    Exposure Computational Models (ECMs) are utilities that simulate situations in which occurs irradiation in a given environment. An ECM is composed primarily by an anthropomorphic model (phantom), and a Monte Carlo code (MC). This paper presents a tutorial of the software Espectro de Raios-X (ERX). This software performs reading and numerical and graphical analysis of text files containing diagnostic X-ray spectra for use in algorithms of radioactive sources in the ECMs of a Grupo de Dosimetria Numerica. The ERX allows the user to select one among several X-ray spectrums in the energy range Diagnostic radiology X-Ray most commonly used in radiology clinics. In the current version of the ERX there are two types of input files: the contained in mspectra.dat file and the resulting of MC simulations in Geant4. The software allows the construction of charts of the Probability Density Function (PDF) and Cumulative Distribution Function (CDF) of a selected spectrum as well as the table with the values of these functions and the spectrum. In addition, the ERX allows the user to make comparative analysis between the PDF graphics of the two catalogs of spectra available, besides being can perform dosimetric evaluations with the selected spectrum. A software of this kind is an important computational tool for researchers in numerical dosimetry because of the diversity of Diagnostic radiology X-Ray machines, which implies in a mass of input data highly diverse. And because of this, the ERX provides independence to the group related to the data origin that is contained in the catalogs created, not being necessary to resort to others. (author)

  4. Implication of occupational exposure to X-Rays diagnosed during pregnancy

    International Nuclear Information System (INIS)

    Frometa Suarez, Ileana

    1998-01-01

    At the present time the risks have been described thoroughly and goods on the inherent fetus to the exhibition give sources ionizing radiations in women that are in period gestation. Presently investigation work is carried out for survey of women exposed to occupational ionizing radiations in reproductive age. The incidence is described and behavior gives these goods and its relationship with other risk factors. In this study the exposure to ionizing radiations is not revealed as main causal factor risk

  5. Cosmic-ray exposure ages of the ordinary chondrites and their significance for parent body stratigraphy

    Science.gov (United States)

    Crabb, J.; Schultz, L.

    1981-01-01

    Improved exposure ages are derived for 201 H, 203 L, and 38 LL chondrites in an effort to understand the characteristics of the chondrite parent body. The Ne-21 exposure ages were calculated from literature values taking into account shielding differences, a trapped component and radiogenic He. The exposure age distributions show clear peaks at 4.5 and 20 million years for the H chondrites, while the Ls and LLs appear more as a continuous series of intermediate peaks which may be modeled by at least six peaks between 1 and 35 million years in the case of L chondrites. The observations that every petrological type occurs in each large peak and contain solar wind gases suggest that the parent bodies have been fragmented and reassembled into a megabreccia. The H meteorites are proposed to represent the surface layer of a body with a substantial, active regolith as indicated by the relatively high abundances of solar gases. The L chondrites, on the other hand, are attributed to a parent body that was fragmented by collision about 500 million years ago.

  6. Analgesia induced by repeated exposure to low dose X-rays in mice, and involvement of the accessory olfactory system in modulation of the radiation effects

    International Nuclear Information System (INIS)

    Miyachi, Yukihisa; Yamada, Takeshi

    1997-01-01

    The effects of low-dose X-rays on mouse nociceptive behavior were examined using a formalin injected test which rated the amount of time the animals spent licking the injected hind-paw. Male ICR White Swiss mice showed a marked suppression of licking behavior after repeated low-dose X-irradiation (5 cGy/day, 6 consecutive days). The most profound effect was observed on the day 30 after irradiation. The decline of licking behavior, however, was not observed at all following olfactory bulbectomy or vomeronasal tract cut. The analgesic effects could be observed in writhing animals administered acetic-acid intraperitoneally. Moreover, analgesia was totally blocked by the administration of N-nitro-L-arginine, a nitric oxide synthase inhibitor, to accessory olfactory bulbs prior to the exposure. The present results indicate that the olfactory system plays an important role in modulation of radiation-induced analgesia, and a possible involvement of nitric oxide in the formation of recognition memory subjected to repeated X-rays. Relatively higher doses (5 cGy x 9 days, 5 cGy x 12 days), however, did not induce such effects, namely, the decline of nociceptive response was limited to the animals irradiated with the smaller dose. (author)

  7. Very low dose and dose-rate X-ray induced adaptive response in human lymphocytes at various cell cycle stages against bleomycin induced chromatid aberrations

    International Nuclear Information System (INIS)

    Hossein Mozdarani; Moghadam, R.N.

    2007-01-01

    Complete text of publication follows. Objective: To study the adaptive response induced by very low doses of X-rays at very low dose rate in human lymphocytes at different cell cycle stages followed by a challenge dose of bleomycin sulphate at G2 phase. Materials and Methods: Human peripheral blood lymphocytes before (G0) and after PHA stimulation (G1 and G2) were exposed to 1 and 5 cGy X-rays generated by a fluoroscopy unit with a dose rate of 5.56 mGy/min and challenged with 5 μg/ml bleomycin sulphate (BLM) 48 hours after culture initiation. Mitotic cells were arrested at metaphase by addition of colcemid in cultures 1.5 h before harvesting. Harvesting and slide preparation was performed using standard method. 100 well spread metaphases were analyzed for the presence of chromatid type aberrations for each sample. Results: Results obtained indicate that there is a linear relationship between the dose of BLM and chromatid aberrations below 5 μg/ml (R=0.93, p<0.0001). The results also show that pretreatment of lymphocytes with low dose X-rays at G0, G1 and G2 phases of the cell cycle significantly reduced the sensitivity of lymphocytes to the clastogenic effects of BLM in G2. Much lower frequencies of chromatid aberrations were observed in X-ray irradiated lymphocytes following BLM treatment (p<0.05). The magnitudes of adaptation induced at different phases of the cell cycle were not significantly different. Furthermore, there was no a significant difference in the magnitude of adaptive response induced by either 1 or 5 cGy X-rays. Conclusion: These observations might indicate that resistance of pre-exposure of lymphocytes to very low doses of X-rays protects them from clastogenic effects of BLM. This effect might be due to initial DNA damage induced in these cells leading to provocation of an active DNA repair mechanism independent of cell cycle stage.

  8. Changes of chromosome aberration rate and micronucleus frequency along with accumulated dose in continuously irradiated mice with a low dose rate of γ-rays

    International Nuclear Information System (INIS)

    Tanaka, Kimio; Izumi, Jun; Yanai, Takanori; Ichinohe, Kazuaki; Matsumoto, Tsuneya

    2003-01-01

    Chromosome aberrations in chronically exposed workers in nuclear facilities and medical radiologists have been reported. However chronological change of chromosome aberration rates along with accumulated dose has not been well studied. Chromosome aberrations and micronuclei in spleen lymphocytes were observed serially in mice continuously irradiated with a low dose rate of 20 mGy/day up to 400 days. Chromosome aberration rates were rapidly increased to 11.1% at 1 Gy, while micronucleus incidence increased at 5 Gy. After these doses their increase rates were saturated. Micronucleus incidence in bone marrow erythroblasts was higher than in spleen cells. These chronological changes of cytogenetic aberrations seem to be induced through a balance between developments of chromosome aberrations and micronuclei, and life span of spleen lymphocytes. These results will be helpful for risk assessment in low dose rate radiation exposure. (author)

  9. Short-time X-ray diffraction with an efficient-optimized, high repetition-rate laser-plasma X-ray-source

    International Nuclear Information System (INIS)

    Kaehle, Stephan

    2009-01-01

    This thesis deals with the production and application of ultrashort X-ray pulses. In the beginning different possibilities for the production of X-ray pulses with pulse durations of below one picosecond are presented, whereby the main topic lies on the so called laser-plasma X-ray sources with high repetition rate. In this case ultrashort laser pulses are focused on a metal, so that in the focus intensities of above 10 16 W/cm 2 dominate. In the ideal case in such way ultrafast electrons are produced, which are responsible for line radiation. In these experiments titanium K α radiation is produced, thes photons possess an energy of 4.51 keV. For the efficient production of line radiation here the Ti:Sa laser is optimized in view of the laser energy and the pulse shape and the influence of the different parameters on the K α production systematically studied. The influences of laser intensity, system-conditioned pre-pulses and of phase modulation are checked. It turns out that beside the increasement of the K α radiation by a suited laser intensity a reduction of the X-ray background radiation is of deciding importance for the obtaining of clear diffraction images. This background radiation is mainly composed of bremsstrahlung. It can be suppressed by the avoidance of intrinsic pre-pulses and by means of 2nd-order phase modulation. By means of optical excitation and X-ray exploration experiments the production of acoustic waves after ultrashort optical excitation in a 150 nm thick Ge(111) film on Si(111) is studied. These acoustic waves are driven by thermal (in this time scale time-independent) and electronic (time dependent) pressure amounts. As essential results it turns out that the relative amount of the electronic pressure increases with decreasing excitation density [de

  10. Ultra-high-resolution inelastic X-ray scattering at high-repetition-rate self-seeded X-ray free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Chubar, Oleg [Brookhaven National Laboratory, Upton, NY 11973 (United States); Geloni, Gianluca [European X-ray Free-Electron Laser, Albert-Einstein-Ring 19, 22761 Hamburg (Germany); Kocharyan, Vitali [Deutsches Elektronen-Synchrotron, 22761 Hamburg (Germany); Madsen, Anders [European X-ray Free-Electron Laser, Albert-Einstein-Ring 19, 22761 Hamburg (Germany); Saldin, Evgeni; Serkez, Svitozar [Deutsches Elektronen-Synchrotron, 22761 Hamburg (Germany); Shvyd’ko, Yuri, E-mail: shvydko@aps.anl.gov [Argonne National Laboratory, Argonne, IL 60439 (United States); Sutter, John [Diamond Light Source Ltd, Didcot OX11 0DE (United Kingdom)

    2016-02-12

    This article explores novel opportunities for ultra-high-resolution inelastic X-ray scattering (IXS) at high-repetition-rate self-seeded XFELs. These next-generation light sources are promising a more than three orders of magnitude increase in average spectral flux compared with what is possible with storage-ring-based radiation sources. In combination with the advanced IXS spectrometer described here, this may become a real game-changer for ultra-high-resolution X-ray spectroscopies, and hence for the studies of dynamics in condensed matter systems. Inelastic X-ray scattering (IXS) is an important tool for studies of equilibrium dynamics in condensed matter. A new spectrometer recently proposed for ultra-high-resolution IXS (UHRIX) has achieved 0.6 meV and 0.25 nm{sup −1} spectral and momentum-transfer resolutions, respectively. However, further improvements down to 0.1 meV and 0.02 nm{sup −1} are required to close the gap in energy–momentum space between high- and low-frequency probes. It is shown that this goal can be achieved by further optimizing the X-ray optics and by increasing the spectral flux of the incident X-ray pulses. UHRIX performs best at energies from 5 to 10 keV, where a combination of self-seeding and undulator tapering at the SASE-2 beamline of the European XFEL promises up to a 100-fold increase in average spectral flux compared with nominal SASE pulses at saturation, or three orders of magnitude more than what is possible with storage-ring-based radiation sources. Wave-optics calculations show that about 7 × 10{sup 12} photons s{sup −1} in a 90 µeV bandwidth can be achieved on the sample. This will provide unique new possibilities for dynamics studies by IXS.

  11. Inquiry on the radiation exposure of the Swiss population by X-ray diagnosis

    International Nuclear Information System (INIS)

    Poretti, G.G.; Bern Univ.; Jonesco-Farca, F.; Lanz, W.

    1976-01-01

    The genetic load on a population is usually expressed in terms of the so-called 'Genetically Significant Dose' (GSD), i.e. the dose which, averaged over the total population, produces the same results as the varying amounts of radiation received in reality by the individuals making up the population. It may be calculated taking into account the following parameters: 1) total number of male and female persons in the population per age group, including the foetuses, 2) average expectation of children per person, 3) number of persons having received a certain type of X-ray examination, and 4) experimental gonadal dose for this examination (for men, women and foetuses - not to be confused with the GSD). The GSD of the Swiss population for the year 1971 was calculated per age group on the basis of physicians' data on some 60,000 patients. The gonadal dose was determined experimentally in various hospitals by means of TLD dosimeters, sensitive high-pressure ionization chambers and normal chambers. The computer programme to calculate the GSD (PL/1 language) is very time-consuming, but its structure allows a new selective investigation to be made later on by merely changing the input. The results show that in Switzerland as in other countries there is a 3-4% increase per year in X-ray examinations for diagnostic purposes. The GSD for 1971 is 42-43 mrad per person in Switzerland as compared to 22 mrad for 1957. The GSD percentage is about 57% for men, about 35% for women and about 8% for foetuses. The number of X-ray examinations is almost equal for general practitioners (53.8%) and hospitals (46.2%). (orig.) [de

  12. Constraints on the bulk Lorentz factor of gamma-ray bursts with the detection rate by Fermi LAT

    Science.gov (United States)

    Chen, Ye; Liu, Ruo-Yu; Wang, Xiang-Yu

    2018-05-01

    The bulk Lorentz factor(Γ) of the outflow is an essential parameter to understanding the physics of gamma-ray burst (GRB). Informations about the Lorentz factors of some individual GRBs have been obtained from the spectral features of the high-energy gamma-ray emissions (>100 MeV), assuming that the spectral breaks or cutoffs are due to the pair-production attenuation (i.e., γγ → e+e-). In this paper, we attempt to interpret the dependence of the LAT detection rate of GRBs on the number of high-energy gamma-rays, taking into account the attenuation effect. We first simulate a long-GRB sample with Monte Carlo method using the luminosity function, rate distribution with redshift and properties of the GRB spectrum. To characterize the distribution of the Lorentz factors, we assume that the Lorentz factors follow the relation Γ =Γ _0E_iso,52k, where Eiso, 52 is the isotropic photon energy in unit of 1052erg. After taking into account the attenuation effect related with the above Lorentz factor distribution, we are able to reproduce the LAT-detected rate of GRBs as the function of the number of gamma-rays for suitable choice of the values of Γ0 and k. The result suggests that the distribution of the bulk Lorentz factor for the majority of GRBs is in the range of 50 - 250.

  13. The x-ray source application test cassette for radiation exposures at the OMEGA laser

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, K. B.; Rekow, V.; Emig, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Fisher, J. H.; Newlander, C. D. [Fifth Gait Technologies, Inc., Huntsville, Alabama 35803 (United States); Horton, R. [Gray Research, Inc., Huntsville, Alabama 35806 (United States); Davis, J. [Defense Threat Reduction Agency, Fort Belvoir, Virginia 22060 (United States)

    2012-10-15

    We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5{sup Double-Prime }) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.

  14. Comparison of x-ray diagnosis associated radiation exposures in Puerto Rico: 1973 vs. 1968

    International Nuclear Information System (INIS)

    Gileadi, M.; Gileadi, A.E.; Musalem, A.

    1975-01-01

    In general, it can be concluded that comparison of 1973 results obtained to date with parallel values for 1968 show a significant improvement in radiation protection practices in Puerto Rico. This improvement, which concerns the whole of society, is not only a result of technical upgrading of the diagnostic equipment, but also and perhaps more significantly, a result of the utmost efforts of professionals: doctors, radiologists and those in radiation protection, to use diagnostic x-rays judiciously, and to reduce the unavoidable doses to a minimum compatible with the diagnostic objective. (U.S.)

  15. Variations in sensitivity of synchronized Chinese hamster cells to oxic and anoxic X-ray exposures

    International Nuclear Information System (INIS)

    Siracka, E.; Littbrand, B.; Clifton, K.H.; Revesz, L.

    1975-01-01

    V-79 Chinese hamster cells in monolayer cultures on glass surfaces were synchronized by treatment with hydroxyurea and then exposed at different times to X-rays in air or in oxygen-free argon. Survival determinations indicated that the oxygen enhancement ratio (OER) as expressed by the ratio of the respective D 0 values varied over a narrow range in the different phases of the cell cycle. These changes resulted from cyclic alterations in both aerobic and anaerobic D 0 values, possibly in n values. (author)

  16. Electrical behavior research of silicon photo-cell used in online monitoring absorbed dose rate of γ-ray

    International Nuclear Information System (INIS)

    Yang Guixia; Li Xiaoyan; Fu Lan; Wu Wenhao; An You; Zeng Fansong

    2015-01-01

    The real-time online monitoring system for γ-ray absorbed dose rate was established to study the relationship between the photocurrent of semi-conductive silicon photo-cell BBZSGD-4 and γ-ray absorbed dose rate under the open circuit. The radioactive experiments in "6"0Co γ radiation field show that photo-cell BBZSGD-4 has good response to "6"0Co γ-ray, and their relationship accords with the linear law. The photocurrent of photo-cell can be up to 1.26 μA when the absorbed dose rate is 94.54 Gy/min. The relationship between photocurrent and the absorbed dose accords with exponential law when absorbed dose rate is 50 Gy/min, and the attenuation of photocurrent is 1% when the absorbed dose is 5445.8 Gy. Thus photo-cell BBZSGD-4 has the potential to be a real-time detector to detect low absorbed dose rate in "6"0Co γ radiation field. (authors)

  17. A pulse shape discriminator with high precision of neutron and gamma ray selection at high counting rate

    International Nuclear Information System (INIS)

    Bialkowski, J.; Moszynski, M.; Wolski, D.

    1989-01-01

    A pulse shape discriminator based on the zero-crossing principle is described. Due to dc negative feedback loops stabilizing the shaping amplifier and the zero-crossing discriminator, the working of the circuit is not affected by the high counting rate and the temperature variations. The pileup rejection circuit built into the discriminator improves the quality of the n-γ separation at high counting rates. A full γ-ray rejection is obtained for a recoil energy of electrons down to 25 keV. At high counting rates the remaining γ-ray contribution is evidently due to the pileup effect which is equal to about 2% at 4x10 5 counts/s. (orig.)

  18. Exposure to Sexist Humor and Rape Proclivity: The Moderator Effect of Aversiveness Ratings

    Science.gov (United States)

    Romero-Sanchez, Monica; Duran, Mercedes; Carretero-Dios, Hugo; Megias, Jesus L.; Moya, Miguel

    2010-01-01

    The aim of this study is to explore the effect of exposure to sexist humor about women on men's self-reported rape proclivity. Earlier studies have shown that exposure to this type of humor increases rape proclivity and that funniness responses to jokes are a key element to consider. However, the role of aversiveness responses has not been…

  19. Dealing with consumer differences in liking during repeated exposure to food; typical dynamics in rating behavior

    NARCIS (Netherlands)

    Horst, ter G.J.; Renken, R.; Nanneti, L.; Dalenberg, J.R.; Wijk, de R.A.

    2014-01-01

    Consumers show high interindividual variability in food liking during repeated exposure. To investigate consumer liking during repeated exposure, data is often interpreted on a product level by averaging results over all consumers. However, a single product may elicit inconsistent behaviors in

  20. Dealing with Consumer Differences in Liking during Repeated Exposure to Food; Typical Dynamics in Rating Behavior

    NARCIS (Netherlands)

    Dalenberg, Jelle R.; Nanetti, Luca; Renken, Remco J.; de Wijk, Rene A.; ter Horst, Gert J.

    2014-01-01

    Consumers show high interindividual variability in food liking during repeated exposure. To investigate consumer liking during repeated exposure, data is often interpreted on a product level by averaging results over all consumers. However, a single product may elicit inconsistent behaviors in

  1. O Star Wind Mass-Loss Rates and Shock Physics from X-ray Line Profiles in Archival XMM RGS Data

    Science.gov (United States)

    Cohen, David

    O stars are characterized by their dense, supersonic stellar winds. These winds are the site of X-ray emission from shock-heated plasma. By analyzing high-resolution X-ray spectra of these O stars, we can learn about the wind-shock heating and X-ray production mechanism. But in addition, the X-rays can also be used to measure the mass-loss rate of the stellar wind, which is a key observational quantity whose value affects stellar evolution and energy, momentum, and mass input to the Galactic interstellar medium. We make this X-ray based mass-loss measurement by analyzing the profile shapes of the X-ray emission lines observed at high resolution with the Chandra and XMM-Newton grating spectrometers. One advantage of our method is that it is insensitive to small-scale clumping that affects density-squared diagnostics. We are applying this analysis technique to O stars in the Chandra archive, and are finding mass-loss rates lower than those traditionally assumed for these O stars, and in line with more recent independent determinations that do account for clumping. By extending this analysis to the XMM RGS data archive, we will make significant contributions to the understanding of both X-ray production in O stars and to addressing the issue of the actual mass-loss rates of O stars. The XMM RGS data archive provides several extensions and advantages over the smaller Chandra HETGS archive: (1) there are roughly twice as many O and early B stars in the XMM archive; (2) the longer wavelength response of the RGS provides access to diagnostically important lines of nitrogen and carbon; (3) the very long, multiple exposures of zeta Pup provide the opportunity to study this canonical O supergiant's X-ray spectrum in unprecedented detail, including looking at the time variability of X-ray line profiles. Our research team has developed a sophisticated empirical line profile model as well as a computational infrastructure for fitting the model to high-resolution X-ray spectra

  2. Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields.

    Science.gov (United States)

    Kelaranta, Anna; Ekholm, Marja; Toroi, Paula; Kortesniemi, Mika

    2016-01-01

    Dental radiography may involve situations where the patient is known to be pregnant or the pregnancy is noticed after the X-ray procedure. In such cases, the radiation dose to the foetus, though low, needs to be estimated. Uniform and widely used guidance on dental X-ray procedures during pregnancy are presently lacking, the usefulness of lead shields is unclear and practices vary. Upper estimates of radiation doses to the foetus and breasts of the pregnant patient were estimated with an anthropomorphic female phantom in intraoral, panoramic, cephalometric and CBCT dental modalities with and without lead shields. The upper estimates of foetal doses varied from 0.009 to 6.9 μGy, and doses at the breast level varied from 0.602 to 75.4 μGy. With lead shields, the foetal doses varied from 0.005 to 2.1 μGy, and breast doses varied from 0.002 to 10.4 μGy. The foetal dose levels without lead shielding were dental radiographic examination.

  3. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  4. N Basin deactivation high exposure rate hardware container offgassing final report

    International Nuclear Information System (INIS)

    Day, R.S.; Palmer, D.L.; Pisarcik, D.J.; Vail, S.W.

    1996-11-01

    The N Reactor's 105-N Basin (N Basin) and the methods of packaging high-exposure rate hardware (HERH) were inspected, and gas bubbles were observed rising from the top surface of the third monolith prepared, Monolith No. 3. The HERH packaging was discontinued until the gas and the source could be explained and the safety of continued operation was verified. This report documents the investigation and the conclusions that support decisions regarding N Basin water removal, future storage, shipping, and Monolith No. 3 burial. Samples indicate that the gas emitted from Monolith No. 3 is almost exclusively hydrogen, containing some air and trace quantities of stable xenon. Gamma-energy analysis indicated trace amounts of 85 Kr in the samples. The literature review and the laboratory test results support the conclusion that aluminum is the only potentially grouted metal capable of corroding rapidly enough to generate the quantities of hydrogen gas that are observed. Based on aluminum components known to be found in the N Basin, the likely source of the aluminum is a used aluminum rupture can. All gas pockets in Monolith No. 3 caused by offgassing should be vented to the surface of the monolith. The peak offgas pressure within Monolith No. 3 (after it is removed from the N Basin water) should be approximately 0.62 psi above atmospheric pressure. Sufficient testing and analysis has been completed to remove Monolith No. 3 from the N Basin water and place the monolith in temporary storage until arrangements have been made for its shipment and disposition

  5. Evaluation of the contribution of contamination of radiotherapy room surfaces in the measure of exposure rate of radioiodine therapy patients

    International Nuclear Information System (INIS)

    Campos, Rafael Ferreira

    2015-01-01

    The contamination of radiotherapy room surfaces is significant and the measures of patient exposure rate are held on the fourth dependencies, relevant questions are raised: the background radiation of the room stay high due to surface contamination, may interfere with the rate of patient exposure at the time of its release? The monitoring site is important to determine whether the patient will be released? The value of the deal activity and the clinical condition of the patient may increase the contamination, influencing the monitoring results? This paper aims to conduct a quantitative analysis of surface contamination of the contribution of therapeutic room at the time is monitored exposure rate from inpatient. Measurements were made regarding the hospitalization of 32 patients with different doses administered activity, age and of both genders. The measurements were performed in the therapeutic rooms at the hospital Brotherhood Santa Casa de Misericordia de Sao Paulo. Exposure rate measurements were performed at the center of the room at 1 meter of the patient on the day of its release. After his release and prior to decontamination, measurements were performed at predetermined landmarks within the therapeutic room. The results revealed that on average background radiation, high due to surface contamination contributes only 2% of the patient dose rate. It can be considered that even with influence of contamination of surfaces, this is insignificant to determine if the patient may or may not be released. This study suggests that the site in which monitoring occurs exposure rate of the patient should not be decisive for liberation thereof. (author)

  6. Intercomparison of the medium energy primary standards for X-ray exposure of NPL and ENEA, Italy

    International Nuclear Information System (INIS)

    Moretti, C.J.; Heaton, J.A.; Laitano, R.F.; Toni, M.P.

    1991-04-01

    An intercomparison between the primary standards of exposure for medium energy X-rays held by the National Physical Laboratory (NPL) and ENEA in Italy is described. The intercomparison, using four different transfer chambers, took place at NPL in December 1989 and at ENEA during March 1990. Measurements were made at four therapy-level qualities, with half value layers of 0.15, 0.5, 1.0 and 2.5 mm Cu (nominal generating voltages of 100, 135, 180 and 250 kV respectively). At the 2.5 mm Cu HVL quality the primary standards were found to agree to within about 0.8%; for the other three qualities the chambers differed by no more than 0.3%. (author)

  7. Development of the town data base: Estimates of exposure rates and times of fallout arrival near the Nevada Test Site

    International Nuclear Information System (INIS)

    Thompson, C.B.; McArthur, R.D.; Hutchinson, S.W.

    1994-09-01

    As part of the U.S. Department of Energy's Off-Site Radiation Exposure Review Project, the time of fallout arrival and the H+12 exposure rate were estimated for populated locations in Arizona, California, Nevada, and Utah that were affected by fallout from one or more nuclear tests at the Nevada Test Site. Estimates of exposure rate were derived from measured values recorded before and after each test by fallout monitors in the field. The estimate for a given location was obtained by retrieving from a data base all measurements made in the vicinity, decay-correcting them to H+12, and calculating an average. Estimates were also derived from maps produced after most events that show isopleths of exposure rate and time of fallout arrival. Both sets of isopleths on these maps were digitized, and kriging was used to interpolate values at the nodes of a 10-km grid covering the pattern. The values at any location within the grid were then estimated from the values at the surrounding grid nodes. Estimates of dispersion (standard deviation) were also calculated. The Town Data Base contains the estimates for all combinations of location and nuclear event for which the estimated mean H+12 exposure rate was greater than three times background. A listing of the data base is included as an appendix. The information was used by other project task groups to estimate the radiation dose that off-site populations and individuals may have received as a result of exposure to fallout from Nevada nuclear tests

  8. Estimated effective dose rates from radon exposure in workplaces and residences within Los Alamos county in New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Whicker, Jeffrey J [Los Alamos National Laboratory; Mcnaughton, Michael [Los Alamos National Laboratory

    2009-01-01

    Many millions of office workers are exposed to radon while at work and at home. Though there has been a multitude of studies reporting the measurements of radon concentrations and potential lung and effective doses associated with radon and progeny exposure in homes, similar studies on the concentrations and subsequent effective dose rates in the workplace are lacking. The purposes of this study were to measure radon concentrations in office and residential spaces in the same county and explore the radiation dose implications. Sixty-five track-etch detectors were deployed in office spaces and 47 were deployed in residences, all within Los Alamos County, New Mexico, USA. The sampling periods for these measurements were generally about three months. The measured concentrations were then used to calculate and compare effective dose rates resulting from exposure while at work and at home. Results showed that full-time office workers receive on average about nine times greater exposure at home than while in the office (691 mrem yr{sup -1} versus 78 mrem yr{sup -1}). The estimated effective dose rate for a more homebound person was 896 mrem yr{sup -1}. These effective dose rates are contrasted against the 100 mrem yr{sup -1} threshold for regulation of a 'radiological worker' defined in the Department of Energy regulations occupational exposure and the 10 mrem yr{sup -1} air pathway effective public dose limit regulated by the Environmental Protection Agency.

  9. The importance of corporate foreign debt as an alternative to currency derivatives in actual management of exchange rate exposures

    DEFF Research Database (Denmark)

    Aabo, Tom

    This empirical study of the exchange rate exposure management of Danish non-financial firms listed on the Copenhagen Stock Exchange shows that debt denominated in foreign currency ("foreign debt") is a very important alternative to the use of currency derivatives. The results show that the relati...

  10. Isopleths of surface concentration and surface exposure rate due to a radioactive cloud released from a stack

    International Nuclear Information System (INIS)

    Kobayashi, Hideo; Yabuta, Hajimu; Katagiri, Hiroshi; Obata, Kazuichi; Kokubu, Morinobu

    1982-03-01

    Various calculations are made to estimate the distributions of concentration and γ-exposure rate due to a radioactive cloud released from a point source to the atmosphere. In this report, the isopleths of concentration and γ-exposure rate which were calculated are given in graphs to enable rapid prediction of the influence of released radioactive material in the emergency situation. Recently there are facilities which are equipped with a system to display the calculation results on CRT; but such practice is rather rare. By placing the calculated isopleths of reduction scale 1/25000 or 1/50000 on the usual map, any facilities without the CRT system can readily estimate the influence of an accidental release. The graphs of isopleths are given with the release height (11 values of 0 to 200 m at about 20 m intervals) and the atmospheric stability (6 classes) as parameters. Calculations of γ-exposure rates were made using the computer code GAMPUL developed by T. Hayashi and T. Shiraishi. In the calculation of radioactive concentrations and γ-exposure rates, the vertical diffusion depths, σsub(z), exceeding 1000 m are taken to be 1000 m according to the Meteorological Guide for the Safety Analysis of Power Reactor (J.AEC). The comparison between with and without this limitation in σsub(z) is made in the case of downwind axial surface distributions. (author)

  11. Sex-dependent Differences in Intestinal Tumorigenesis Induced in Apc1638N/+ Mice by Exposure to {gamma} Rays

    Energy Technology Data Exchange (ETDEWEB)

    Trani, Daniela [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Maastricht Radiation Oncology (MaastRO) Lab, GROW-School for Oncology and Developmental Biology, University of Maastricht (Netherlands); Moon, Bo-Hyun [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Kallakury, Bhaskar; Hartmann, Dan P. [Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Datta, Kamal [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Fornace, Albert J., E-mail: af294@georgetown.edu [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Center of Excellence in Genomic Medicine Research (CEGMR), King Abdulaziz University, Jeddah (Saudi Arabia)

    2013-01-01

    Purpose: The purpose of the present study was to assess the effect of 1 and 5 Gy radiation doses and to investigate the interplay of gender and radiation with regard to intestinal tumorigenesis in an adenomatous polyposis coli (APC) mutant mouse model. Methods and Materials: Apc1638N/+ female and male mice were exposed whole body to either 1 Gy or 5 Gy of {gamma} rays and euthanized when most of the treated mice became moribund. Small and large intestines were processed to determine tumor burden, distribution, and grade. Expression of proliferation marker Ki-67 and estrogen receptor (ER)-{alpha} were also assessed by immunohistochemistry. Results: We observed that, with both 1 Gy and 5 Gy of {gamma} rays, females displayed reduced susceptibility to radiation-induced intestinal tumorigenesis compared with males. As for radiation effect on small intestinal tumor progression, although no substantial differences were found in the relative frequency and degree of dysplasia of adenomas in irradiated animals compared with controls, invasive carcinomas were found in 1-Gy- and 5-Gy-irradiated animals. Radiation exposure was also shown to induce an increase in protein levels of proliferation marker Ki-67 and sex-hormone receptor ER-{alpha} in both non tumor mucosa and intestinal tumors from irradiated male mice. Conclusions: We observed important sex-dependent differences in susceptibility to radiation-induced intestinal tumorigenesis in Apc1638N/+ mutants. Furthermore, our data provide evidence that exposure to radiation doses as low as 1 Gy can induce a significant increase in intestinal tumor multiplicit