WorldWideScience

Sample records for ray exposure dating

  1. Evidence from cosmic ray exposure (CRE) dating for the existence of a pre-Minoan caldera on Santorini, Greece

    Science.gov (United States)

    Athanassas, C. D.; Bourlès, D. L.; Braucher, R.; Druitt, T. H.; Nomikou, P.; Léanni, L.

    2016-05-01

    Cosmic ray exposure (CRE) dating was performed on the caldera cliffs of Santorini with the aim of detecting cliff segments predating the Minoan eruption (17th century BCE). The methodology involved the determination of in situ-produced cosmogenic 36Cl concentration in basaltic-to-rhyodacitic whole rocks cropping out in the cliffs. After the samples were processed following the chemical protocol of 36Cl preparation for silicate rocks, 36Cl concentrations were measured by accelerator mass spectrometry (AMS). Important challenges during the implementation procedure were related to large amounts of radiogenic 36Cl, complex modeling of inherited 36Cl, and dominance of the thermal and epithermal (low-energy) neutron capture production pathway. Nevertheless, quantitative assessments on the basis of the contribution of the low-energy neutron capture pathway percent to the total production rate validated the calculated CRE dates. Current CRE ages demonstrate that an ancient caldera existed on pre-Minoan Santorini, occupying at least the northern half of the modern-day caldera.

  2. Cosmic ray exposure dating with in situ produced cosmogenic 3He: results from young Hawaiian lava flows

    Science.gov (United States)

    Kurz, M.D.; Colodner, D.; Trull, T.W.; Moore, R.B.; O'Brien, K.

    1990-01-01

    In an effort to determine the in situ production rate of spallation-produced cosmogenic 3He, and evaluate its use as a surface exposure chronometer, we have measured cosmogenic helium contents in a suite of Hawaiian radiocarbon-dated lava flows. The lava flows, ranging in age from 600 to 13,000 years, were collected from Hualalai and Mauna Loa volcanoes on the island of Hawaii. Because cosmic ray surface-exposure dating requires the complete absence of erosion or soil cover, these lava flows were selected specifically for this purpose. The 3He production rate, measured within olivine phenocrysts, was found to vary significantly, ranging from 47 to 150 atoms g-1 yr-1 (normalized to sea level). Although there is considerable scatter in the data, the samples younger than 10,000 years are well-preserved and exposed, and the production rate variations are therefore not related to erosion or soil cover. Data averaged over the past 2000 years indicate a sea-level 3He production rate of 125 ?? 30 atoms g-1 yr-1, which agrees well with previous estimates. The longer record suggests a minimum in sea level normalized 3He production rate between 2000 and 7000 years (55 ?? 15 atoms g-1 yr-1), as compared to samples younger than 2000 years (125 ?? 30 atoms g-1 yr-1), and those between 7000 and 10,000 years (127 ?? 19 atoms g-1 yr-1). The minimum in production rate is similar in age to that which would be produced by variations in geomagnetic field strength, as indicated by archeomagnetic data. However, the production rate variations (a factor of 2.3 ?? 0.8) are poorly determined due to the large uncertainties in the youngest samples and questions of surface preservation for the older samples. Calculations using the atmospheric production model of O'Brien (1979) [35], and the method of Lal and Peters (1967) [11], predict smaller production rate variations for similar variation in dipole moment (a factor of 1.15-1.65). Because the production rate variations, archeomagnetic data

  3. Cosmic ray exposure dating of geo-morphic surface features using in situ-produced 10Be: tectonic and climatic implications

    International Nuclear Information System (INIS)

    Siame, L.; Bellier, O.; Sebrier, M.; Braucher, R.; Bourles, D.L.

    2001-01-01

    The evolution of continental landforms is mainly modulated by the impact of climatic and tectonic processes. Because of their distinctive morphology and the periodicity of their deposition, climatically induced landforms such as alluvial fans or terraces are well suited to infer rates of tectonic and continental climatic processes. Within tectonically active regions, an important step consists in dating displaced geomorphic features to calculate slip rates on active faults. Dating is probably the most critical tool because it is generally much more simpler to measure deformation resulting from tectonic activity than it is to accurately date when that deformation occurred. Recent advances in analytical chemistry and nuclear physics (accelerator mass spectrometry) now allow quantitative abundance measurements of the extremely rare isotopes produced by the interaction of cosmic rays with surface rocks and soils, the so-called in situ-produced cosmogenic nuclides ( 3 He, 10 Be, 21 Ne, 26 Al, 36 Cl), and allow to directly date the duration that a landform has been exposed to cosmic rays at the Earth's surface (Lal, 1991; Nishiizumi et al., 1993; Cerling and Craig, 1994; Clark et al., 1995]. In fact, the abundance of these cosmo-nuclides is proportional to landscape stability and, under favorable circumstances, their abundance within surface rocks can be used as a proxy for erosion rate or exposure age. These cosmo-nuclides thus provide geomorphologists with the opportunity to constrain rates of landscape evolution. This paper presents a new approach that combines cosmic ray exposure (CRE) dating using in situ-produced 10 Be and geomorphic as well as structural analyse. This approach has been applied on two active strike-slip and reverse faults located in the Andean fore-land of western Argentina. These two case studies illustrate how CRE dating using in situ-produced 10 Be is particularly well suited for geomorphic studies that aim to estimate the respective control of

  4. Seismic hazard reappraisal from combined structural geology, geomorphology and cosmic ray exposure dating analyses: the Eastern Precordillera thrust system (NW Argentina)

    Science.gov (United States)

    Siame, L. L.; Bellier, O.; Sébrier, M.; Bourlès, D. L.; Leturmy, P.; Perez, M.; Araujo, M.

    2002-07-01

    Because earthquakes on large active thrust or reverse faults are not always accompanied with surface rupture, paleoseismological estimation of their associated seismic hazard is a difficult task. To improve the seismic hazard assessments in the Andean foreland of western Argentina (San Juan Province), this paper proposes a novel approach that combines structural geology, geomorphology and exposure age dating. The Eastern Precordillera of San Juan is probably one of the most active zones of thrust tectonics in the world. We concentrated on one major regional active reverse structure, the 145 km long Villicúm-Pedernal thrust, where this methodology allows one to: (1) constrain the Quaternary stress regime by inversion of geologically determined slip vectors on minor or major fault planes; (2) analyse the geometry and the geomorphic characteristics of the Villicúm-Pedernal thrust; and (3) estimate uplift and shortening rates through determination of in situ-produced 10Be cosmic ray exposure (CRE) ages of abandoned and uplifted alluvial terraces. From a structural point of view, the Villicúm-Pedernal thrust can be subdivided into three thrust portions constituting major structural segments separated by oblique N40°E-trending fault branches. Along the three segments, inversion of fault slip data shows that the development of the Eastern Precordillera between 31°S and 32°S latitude is dominated by a pure compressive reverse faulting stress regime characterized by a N110°+/- 10°E-trending compressional stress axis (σ1). A geomorphic study realized along the 18 km long Las Tapias fault segment combined with CRE ages shows that the minimum shortening rate calculated over the previous ~20 kyr is at least of the order of 1 mm yr-1. An earthquake moment tensor sum has also been used to calculate a regional shortening rate caused by seismic deformation. This analysis of the focal solutions available for the last 23 yr shows that the seismic contribution may be three

  5. Violence exposure and teen dating violence among African American youth.

    Science.gov (United States)

    Black, Beverly M; Chido, Lisa M; Preble, Kathleen M; Weisz, Arlene N; Yoon, Jina S; Delaney-Black, Virginia; Kernsmith, Poco; Lewandowski, Linda

    2015-07-01

    This study examines the relationships between exposure to violence in the community, school, and family with dating violence attitudes and behaviors among 175 urban African American youth. Age, gender, state support and experiences with neglect, school violence, and community violence were the most significant predictors of acceptance of dating violence. Experiences with community violence and age were important predictors of dating violence perpetration and victimization. Findings highlight the importance of planning prevention programs that address variables affecting attitudes and behaviors of high-risk youth who have already been exposed to multiple types of violence. © The Author(s) 2014.

  6. {sup 36}Cl exposure dating with a 3-MV tandem

    Energy Technology Data Exchange (ETDEWEB)

    Steier, Peter, E-mail: peter.steier@univie.ac.a [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Forstner, Oliver; Golser, Robin; Kutschera, Walter; Martschini, Martin [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Merchel, Silke [CEREGE, CNRS-IRD-Universite Aix-Marseille, Europole Mediterraneen de L' Arbois, 13545 Aix-en-Provence (France); Forschungszentrum Dresden-Rossendorf, D-01314 Dresden (Germany); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Orlowski, Tobias; Priller, Alfred [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Vockenhuber, Christof [Forschungszentrum Dresden-Rossendorf, D-01314 Dresden (Germany); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Wallner, Anton [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland)

    2010-04-15

    {sup 36}Cl AMS measurements at natural isotopic concentrations have yet been performed only at tandem accelerators with 5 MV terminal voltage or beyond. We have developed a method to detect {sup 36}Cl at natural terrestrial isotopic concentrations with a 3-MV system, operated above specifications at 3.5 MV. An effective separation was obtained with an optimized split-anode ionization chamber design (adopted from the ETH/PSI Zurich AMS group), providing a suppression factor of up to 30,000 for the interfering isobar {sup 36}S. Despite the good separation, a relatively high sulfur output from the ion source ({sup 36}S{sup -}/{sup 35}Cl{sup -} approx 4 x 10{sup -10} for samples prepared from chemically pure reagents), and a possibly cross contamination resulted in a background corresponding to {sup 36}Cl/Cl approx 3 x 10{sup -14}. The method was applied to samples containing between 10{sup 5} and 10{sup 6} atoms {sup 36}Cl/g rock from sites in Italy and Iran, which were already investigated by other laboratories for surface exposure dating. The {sup 36}Cl/Cl ratios in the range from 2 x 10{sup -13} to 5 x 10{sup -12} show a generally good agreement with the previous results. These first measurements demonstrate that also 3-MV tandems, constituting the majority of dedicated AMS facilities, are capable of {sup 36}Cl exposure dating, which is presently the domain of larger facilities.

  7. A paediatric X-ray exposure chart

    Energy Technology Data Exchange (ETDEWEB)

    Knight, Stephen P, E-mail: stephen.knight@health.qld.gov.au [Department of Medical Imaging, Royal Children' s Hospital, Brisbane, Queensland (Australia)

    2014-09-15

    The aim of this review was to develop a radiographic optimisation strategy to make use of digital radiography (DR) and needle phosphor computerised radiography (CR) detectors, in order to lower radiation dose and improve image quality for paediatrics. This review was based on evidence-based practice, of which a component was a review of the relevant literature. The resulting exposure chart was developed with two distinct groups of exposure optimisation strategies – body exposures (for head, trunk, humerus, femur) and distal extremity exposures (elbow to finger, knee to toe). Exposure variables manipulated included kilovoltage peak (kVp), target detector exposure and milli-ampere-seconds (mAs), automatic exposure control (AEC), additional beam filtration, and use of antiscatter grid. Mean dose area product (DAP) reductions of up to 83% for anterior–posterior (AP)/posterior–anterior (PA) abdomen projections were recorded postoptimisation due to manipulation of multiple-exposure variables. For body exposures, the target EI and detector exposure, and thus the required mAs were typically 20% less postoptimisation. Image quality for some distal extremity exposures was improved by lowering kVp and increasing mAs around constant entrance skin dose. It is recommended that purchasing digital X-ray equipment with high detective quantum efficiency detectors, and then optimising the exposure chart for use with these detectors is of high importance for sites performing paediatric imaging. Multiple-exposure variables may need to be manipulated to achieve optimal outcomes.

  8. X-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients and a skeleton encased in plastic were instrumented with LiF thermoluminescent dosimeters to determine radiation exposures delivered from full-face diagnostic dental X-rays. Measurements were made using various panoramic radiographical and periapical machines. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices. (author)

  9. 10Be surface exposure dating of raised marine terraces and glacial moraines

    International Nuclear Information System (INIS)

    Graham, I.J.; Zondervan, A.

    2004-01-01

    Geological processes at the Earth's surface have a profound effect on human activity. Interactions between various elements of the landscape influence the harshness of floods, the danger of earthquakes, the severity of landslides, the potential of soil erosion of croplands, and the reliability of water supplies. Landscape constantly evolves through the forces of tectonics, climate, weathering and hydrology, and analysis of its evolution provides insight into the controls on processes. Of prime importance is an understanding of the timing of events, allowing determination of cause and effect, and rates of change. The time period most relevant to this is the last two million years, the Quaternary Period. Geological surfaces and deposits are, however, difficult to date by conventional methods within this time period. Surface exposure-age dating (SED) using cosmogenic isotopes (i.e. nuclides produced by cosmic rays) can help solve this problem. (author). 10 refs., 2 figs., 1 tab

  10. Detailed chronology of a giant Pleistocene rock-avalanche sequence in the hyperarid southern Peru revealed by jointly applied 10Be and 3He cosmic ray exposure dating : The Study case of the Cerro Caquilluco landslide complex.

    Science.gov (United States)

    Swann, Zerathe; Laurence, Audin; Carlos, Benavente; Régis, Braucher; Pierre-Henri, Blard; Didier, Bourlès; Julien, Carcaillet; Fabrizio, Delgado; Pascal, Lacroix; Valderrama Patricio, Murillo; Aster Team

    2015-04-01

    Giant landslides are recognized to be remarkably abundant on the Western Andean front of southern Peru and northern Chile, especially in the Arica Bend region (e.g. Crosta et al., 2014a). This area is characterized by strong topographic gradients and subsequent incision of deep canyons, due to the evolution of the Andean range that provide suitable conditions for the development of such instabilities. The climate is hyper-arid (Atacama Desert), although rare but highly impulsive wet events have been evidenced since the Pleistocene. In parallel, this region is submitted to strong (Mw 8-9) and recurrent (~100 yrs) subduction earthquakes. Previous studies suggest that large landslides represent the main agent of erosion of the Western Cordillera, providing soft material for subsequent fluvial remobilization. However the lack of time constrains on the numerous fossil landslides identified away from major canyons still hamper to assess a real mass balance of sliding material versus the known fluvial erosion and tectonic uplift rates. Finally the role of landslides in the long-term erosion rates of the Andean range on its arid flank remains quantitatively unknown. Recently, two studies gave divergent opinions about the main factor supposed to control the slope failures in that region. Based on cosmogenic nuclides derived erosion rates, McPhillips et al. (2014) argue that the last Holocene climate variation did not have had any effect on the rate of landsliding, suggesting that here landslides are mainly triggered by earthquake. On the other hand, Margirier et al. (2014) have showed a temporal correlation between a failure episode of the giant Chuquibamba landslide and the Ouki wet climatic event identified on the Altiplano ~100 ka ago. In this study we focus on dating the Cerro Caquilluco rock avalanche complex described by Crosta et al. (2014). With a total volume of about 15 km3, a length of 43 km and an internal structure characterized by various depositional lobes

  11. Project Date SMART: a Dating Violence (DV) and Sexual Risk Prevention Program for Adolescent Girls with Prior DV Exposure.

    Science.gov (United States)

    Rizzo, Christie J; Joppa, Meredith; Barker, David; Collibee, Charlene; Zlotnick, Caron; Brown, Larry K

    2018-05-01

    This study assessed the initial feasibility, acceptability, and efficacy of an intervention aimed at reducing dating violence and sexual risk behavior in a sample of adolescent girls (ages 14-17) with prior exposure to physical dating violence (DV). One hundred and nine girls were randomly assigned to Date SMART (Skills to Manage Aggression in Relationships for Teens) or a Knowledge-only (KO) comparison group. Both intervention arms consisted of six, weekly 2-h sessions and one "booster" session 6 weeks later. Based on principles of cognitive behavioral therapy, the Date SMART intervention was designed to target common underlying skills deficits linked to both DV and sexual risk behavior in adolescent females: depression, self-regulation deficits, and interpersonal skills deficits. Assessments were administered at four time points (baseline, 3, 6, and 9 months). The Date SMART group was effective as reducing sexual DV involvement across the 9-month follow-up period. Both groups evidenced clinically meaningful reductions in physical, emotional, and digital DV involvement, total time in dating relationships, as well as reductions in depression. Findings indicate that delivering a DV and sexual risk prevention intervention to DV-affected adolescent girls is feasible and well-received. Furthermore, a skills-based approach that addresses the co-occurrence of DV and sexual risk behavior may be particularly useful for promoting reductions of sexual DV among high-risk adolescent girls. A future, large-scale trial with an inactive comparison condition is needed to evaluate the efficacy of Date SMART further. Clinical Trials, NCT01326195, and http://www.clinicaltrials.gov.

  12. Cosmic-ray exposure records and origins of meteorites

    International Nuclear Information System (INIS)

    Reedy, R.C.

    1985-01-01

    The cosmic-ray records of meteorites can be used to infer much about their origins and recent histories. Some meteorites had simple cosmic-ray exposure histories, while others had complex exposure histories with their cosmogenic products made both before and after a collision in space. The methods used to interpret meteorites' cosmic-ray records, especially identifying simple or complex exposure histories, often are inadequate. Besides spallogenic radionuclides and stable nuclides, measurements of products that have location-sensitive production rates, such as the tracks of heavy cosmic-ray nuclei or neutron-capture nuclides, are very useful in accurately determining a meteorite's history. Samples from different, known locations of a meteorite help in studying the cosmic-ray record. Such extensive sets of meteorite measurements, plus theoretical modeling of complex histories, will improve our ability to predict the production of cosmogenic nuclides in meteorites, to distinguish simple and complex exposure histories, and to better determine exposure ages

  13. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    International Nuclear Information System (INIS)

    Freiesleben, Trine; Sohbati, Reza; Murray, Andrew; Jain, Mayank; Al Khasawneh, Sahar; Hvidt, Søren; Jakobsen, Bo

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescence–depth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated luminescence-depth profile from a feldspar-rich granite cobble from an archaeological site near Aarhus, Denmark. This profile shows qualitative evidence for multiple daylight exposure and burial events; these are quantified using the model developed here. By determining the burial ages from the surface layer of the cobble and by fitting the new model to the luminescence profile, it is concluded that the cobble was well bleached before burial. This indicates that the OSL burial age is likely to be reliable. In addition, a recent known exposure event provides an approximate calibration for older daylight exposure events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible to determine the length of a fossil exposure, using a known natural light exposure as calibration. - Highlights: • Evidence for multiple exposure and burial events in the history of a single cobble. • OSL rock surface dating model improved to include multiple burial/exposure cycles. • Application of the new model quantifies burial and exposure events.

  14. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    DEFF Research Database (Denmark)

    Freiesleben, Trine Holm; Sohbati, Reza; Murray, Andrew

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure...... and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescenceedepth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated...... events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible...

  15. Surface exposure dating of non-terrestrial bodies using optically stimulated luminescence: A new method

    DEFF Research Database (Denmark)

    Sohbati, Reza; Jain, Mayank; Murray, Andrew

    2012-01-01

    We propose a new method for in situ surface exposure dating of non-terrestrial geomorphological features using optically stimulated luminescence (OSL); our approach is based on the progressive emptying of trapped charge with exposure to light at depth into a mineral surface. A complete model of t...... charge population. The potential dating applications for (a) include dust accumulation, volcanic rocks and impact-related sediments, and for (b) fault scarps, rock-falls, landslides and ice-scoured bedrock. Using assumptions based on terrestrial observations we expect that this approach...

  16. Preparation of exposures charts for X-ray tubes

    International Nuclear Information System (INIS)

    Zoofan, B.

    1988-01-01

    An exposure chart is a fundamental graph which provides guidance of the exposure conditions in relation to the thickness for a given specimen. It must be prepared specially for the X-ray unit and the type of the film to be used. Although exposure charts are available for each particular X-ray tube from its manufacturer, individual radiographic laboratory should be able to prepare its own exposure charts in a precise manner. Here a typical procedure to prepare such a chart is provided in a practical way with some necessary recommendations

  17. Cosmic ray exposure ages of features and events at the Apollo landing sites

    International Nuclear Information System (INIS)

    Arvidson, R.; Crozaz, G.; Drozd, R.J.; Hohenberg, C.M.; Morgan, C.J.

    1975-01-01

    Cosmic ray exposure ages of lunar samples have been used to date surface features related to impact cratering and downslope movement of material. Only when multiple samples related to a feature have the same rare gas exposure age, or when a single sample has the same 81 Kr-Kr and track exposure age can a feature be considered reliably dated. Because any single lunar sample is likely to have had a complex history, assignment of ages to features based upon only one determination by any method should be avoided. Based on the above criteria, there are only five well-dated lunar features: Cone Crater (Apollo 14) 26 m.y., North Ray Crater (Apollo 16) 50 m.y., South Ray Crater (Apollo 16) 2 m.y., the emplacement of the Station 6 boulders (Apollo 17) 22 m.y., and the emplacement of the Station 7 boulder (Apollo 17) 28 m.y. Other features are tentatively dated or have limits set on their ages: Bench Crater (Apollo 12) =50 m.y. (Auth.)

  18. Trends in x-ray photography and patient exposure dose

    International Nuclear Information System (INIS)

    Orito, Takeo; Sanada, Shigeru; Maekawa, Ryuichi; Koshida, Kichiro; Hiraki, Tatsunosuke

    1980-01-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired. (J.P.N.)

  19. Exposure of nitrous oxide to X-rays

    International Nuclear Information System (INIS)

    Yanagida, H.

    1980-01-01

    A study was performed to determine how much NO and NO 2 is produced when nitrous oxide is exposed to X-radiation. Polyethylene bottles filled with either nitrous oxide alone or with nitrous oxide and 30% oxygen were placed 30 cm from the X-ray tube at a standard X-ray beam setting for chest fluoroscopy for 0 to 5 minutes. In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray exposure, this study suggests another potentially hazardous interaction that may occur secondary to the administration of an anaesthetic in the presence of X-irradiation as in pulmonary angiography, cardiac catheterisation, and fluoroscopic bronchoscopy or biopsy. (author)

  20. OSL surface exposure dating of a lithic quarry in Tibet: Laboratory validation and application

    DEFF Research Database (Denmark)

    Gliganic, L.A.; Meyer, M.C.; Sohbati, R.

    2018-01-01

    developed OSL Surface exposure dating technique (OSL-Surf) to date flake scars at lithic quarry sites. We performed the first quantitative validation of the model describing the OSL-Surf dating technique using a controlled laboratory experiment. Our results show that longer laboratory bleaching durations......-depth profile that could be used to calibrate the model to estimate the exposure duration of a flake scar associated with human exploitation of the area. Finally, we observe that the μ parameter of the OSL-Surf model varies considerably between the laboratory-bleached and two naturally daylight-bleached...... datasets, despite having identical lithologies. We thus infer that, in addition to lithological controls, the μ parameter is primarily sensitive to the daylight irradiation geometry and only weakly dependent on spectrum of the incident light; this interpretation implies a narrow effective bleaching...

  1. AIRGAMMA, External Gamma-Ray Exposure from Radioactive Cloud

    International Nuclear Information System (INIS)

    Hidaka, Akihide; Iijima, Tshinori

    1989-01-01

    1 - Description of program or function: AIRGAMMA calculates quickly the external exposure to gamma rays from a radioactive cloud. 2 - Method of solution: The external exposure is calculated by interpolating the normalized doses providing on the basis of the Gaussian plume model. 3 - Restrictions on the complexity of the problem: Memory requirement is 30 Kbytes

  2. Cosmic-ray exposure records and origins of meteorites

    International Nuclear Information System (INIS)

    Reedy, R.C.

    1985-01-01

    The cosmic-ray records of meteorites are used to infer much about their origins and recent histories. The methods used to interpret meteorites cosmic-ray records, especially identifying simple or complex exposure histories, often are inadequate. Spallogenic radionuclides, stable nuclides, and measurements of products that have location-sensitive production rates, such as the tracks of heavy cosmic-ray nuclei or neutron-capture nuclides, are very useful in accurately determining a meteorite's history. Samples from different, known locations of a meteorite help in studying the cosmic-ray record. Such extensive sets of meteorite measuremetns, plus theoretical modeling of complex histories, improves the ability to predict the production of cosmogenic nuclides in meteorites, to distinguish simple and complex exposure histories, and to better determine exposure ages

  3. Nitrous oxide pollution during x-ray exposure

    International Nuclear Information System (INIS)

    Yanagida, Hisashi; Nakajima, Michiaki.

    1980-01-01

    X-radiation has been shown to produce NO and NO 2 in the presence of nitrous oxide. The purpose of the present study was to confirm how much NO and NO 2 was produced when constant amount of nitrous oxide was exposed by constant X-radiation. Twenty polyethylene bottles (capacity 10 litres) were filled with nitrous oxide alone. Another 20 bottles were filled with nitrous oxide and 30% oxygen. Each bottle was placed at a distance of 30 cm from X-ray tube and they were directly in the line of the X-ray beam at a setting of 90 KV at 0.5 mA, a standard setting for chest fluoroscopy. The range of duration of X-ray exposure was from 0 (control), to 2, 3, and 5 minutes in 5 bottles each, respectively. A colorimetric recording method (Saltzman) and a chemiluminescent monitor were used for measurement of NO and NO 2 . In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray, this study suggests another potentially hazardous interaction that may occur secondary to the administration of anesthetic in the presence of X-irradiation such as pulmonary angiography, cardiac catheterization, and fluoroscopic bronchoscopy or biopsy under general anesthesia. (author)

  4. A new sampling technique for surface exposure dating using a portable electric rock cutter

    Directory of Open Access Journals (Sweden)

    Yusuke Suganuma

    2012-07-01

    Full Text Available Surface exposure dating using in situ cosmogenic nuclides has contributed to our understanding of Earth-surface processes. The precision of the ages estimated by this method is affected by the sample geometry; therefore, high accuracy measurements of the thickness and shape of the rock sample (thickness and shape is crucial. However, it is sometimes diffi cult to meet these requirements by conventional sampling methods with a hammer and chisel. Here, we propose a new sampling technique using a portable electric rock cutter. This sampling technique is faster, produces more precisely shaped samples, and allows for a more precise age interpretation. A simple theoretical modeldemonstrates that the age error due to defective sample geometry increases as the total sample thickness increases, indicating the importance of precise sampling for surface exposure dating.

  5. Estimation of production rates for in-situ cosmogenic isotopes and application to surface exposure dating: certitudes and uncertainties

    International Nuclear Information System (INIS)

    Graham, I.J.

    1996-01-01

    Cosmogenic nuclides, produced in-situ in rocks by the action of cosmic rays on target nuclei, are increasingly being employed by earth scientists in a wide variety of applications. For example, surface exposure dating is used to determine erosion rates, the age of debris flows, alluvial fans, volcanic eruptions, meteoritic impact craters, and glacial deposits, and the timing of recent movement along faults and tectonic uplift. The technique can thus play a vital role in the study of potential hazards from geological processes, by establishing recurrence intervals between them, and establish chronologies and periodicities for major paleoclimatic events. Before surface exposure dating methods using cosmogenic isotopes can be applied even more widely, production rates of the main nuclides of interest must be better known, and their temporal and spatial variabilities determined. This paper summarises the present state of knowledge on production rates of the currently most useful nuclides ( 10 Be, 26 Al, 36 Cl, 14 C, 3 He and 21 Ne), discusses the main areas of concern, and makes suggestions for future improvement. (author). 83 refs., 7 tabs., 11 figs

  6. 36Chlorine exposure dating of a terminal moraine in the Galicica Mountains, Macedonia

    Science.gov (United States)

    Gromig, R.; Mechernich, S.; Ribolini, A.; Dunai, T. J.; Wagner, B.

    2015-12-01

    The glaciation history of the Balkan Peninsula is subject of research since the late 19th century. To date, only a few moraines on the Balkan Peninsula are dated, mainly using 10Be exposure dating applied on quartz bearing rocks. Since large parts of the Balkan Peninsula mountains are composed of carbonatic rocks, absolute age dating is restricted to 36Cl exposure dating, which, to date, was not conducted in this region yet. So far, an absolute chronological control in limestone-dominated areas is limited to U-series minimum ages of calcitic cements. In order to obtain more information about the timing of the glaciation history on the Balkan Peninsula, we investigated a terminal moraine in a NNE-facing cirque in the Galicica Mountains (40°56´N, 20°49´E) in the Former Yugoslav Republic of Macedonia. The cirque comprises a series of nested moraine ridges at the base of the cirque wall, with the largest one being sampled. Samples from five limestone boulders in crest position (≈ 2050 m a.s.l.) were taken and pre-treated for AMS measurement at the University of Cologne. Three preliminary ages point to a moraine formation in the course of a late Pleistocene glaciation, either Last Glacial Maximum or Younger Dryas. The data were discussed concerning corrections for topographic shielding, snow cover, inheritance, and erosion. However, five AMS re-measurements are currently in progress in order to refine the correlation of the moraine formation to a specific glacial period. The resulting ages will be compared to sediments of the adjacent Lakes Ohrid and Prespa, which represent valuable climatic and environmental archives. Several studies on these sediments were carried out in order to reconstruct relative changes in temperature and moisture availability. Moreover, the inferred moraine formation ages will be compared to glaciation reconstructions of other mountainous regions on the Balkan Peninsula to improve the knowledge on past climatic conditions.

  7. Predicting Adolescent Dating Violence Perpetration: Role of Exposure to Intimate Partner Violence and Parenting Practices.

    Science.gov (United States)

    Latzman, Natasha E; Vivolo-Kantor, Alana M; Holditch Niolon, Phyllis; Ghazarian, Sharon R

    2015-09-01

    Exposure to adult intimate partner violence (IPV) places youth at risk for a range of outcomes, including perpetration of adolescent dating violence (ADV). However, there is variability in the effect of IPV exposure, as many youth who are exposed to IPV do not go on to exhibit problems. Thus, research is needed to examine contextual factors, such as parenting practices, to more fully explain heterogeneity in outcomes and better predict ADV perpetration. The current research draws from a multisite study to investigate the predictive power of IPV exposure and parenting practices on subsequent ADV perpetration. Participants included 417 adolescents (48.7% female) drawn from middle schools in high-risk, urban communities. IPV exposure, two types of parenting practices (positive parenting/involvement and parental knowledge of their child's dating), and five types of ADV perpetration (threatening behaviors, verbal/emotional abuse, relational abuse, physical abuse, and sexual abuse) were assessed at baseline (2012) and approximately 5 months later (2013) via adolescent report. Analyses (conducted in 2015) used a structural equation modeling approach. Structural models indicated that IPV exposure was positively related only to relational abuse at follow-up. Further, adolescents who reported parents having less knowledge of dating partners were more likely to report perpetrating two types of ADV (physical and verbal/emotional abuse) at follow-up. Analyses did not demonstrate any significant interaction effects. Results fill a critical gap in understanding of important targets to prevent ADV in middle school and highlight the important role that parents may play in ADV prevention. Published by Elsevier Inc.

  8. A re-evaluation of the 0-10 ka 10Be production rate for exposure dating obtained from the Koefels (Austria) landslide

    International Nuclear Information System (INIS)

    Kubik, Peter W.; Ivy-Ochs, Susan

    2004-01-01

    The sea level, high latitude 10 Be production rate for exposure dating obtained from the giant 9.8 ka landslide of Koefels (Austria) has been calculated based on a re-assessment of the contribution of the muonic cosmic ray component. The 0-10 ka production rate value is 5.44 ± 0.19 10 Be atoms/y g quartz

  9. X-ray exposure from colour TV sets

    International Nuclear Information System (INIS)

    Nambi, K.S.V.; Viswanathan, P.S.

    1988-01-01

    A survey has been made of the X-ray exposures from colour television sets of eight different brands manufactured in India and one of foreign make. The high sensitivity of natural CaF 2 TL phosphor to low energy photons has been taken advantage of, in measuring the extremely low levels of the X-ray emis sion from the TV sets. The measured exposures range from 8 to 27 μRh -1 and are well below the radiation safety limit internationally adopted. (author). 4 tabs

  10. Excessive exposures of diagnostic X-ray workers in India

    International Nuclear Information System (INIS)

    Ambiger, T.Y.; Shenoy, K.S.; Patel, P.H.

    1980-01-01

    The excessive exposures (i.e. exceeding 400 mrems per fortnight) of diagnostic X-ray workers revealed under the countrywide personnel monitoring programme in India have been analysed. The analysis covers the data collected over a period of ten years during 1965-1974. The radiation workers in medical X-ray diagnostic group receiving an excess dose are found to be less than 1%. Each case of the excess dose is throughly investigated and nongenuine cases are separated and causes for genuine excessive exposures are traced. The causes and the corrective measures are enumerated. (M.G.B.)

  11. Optically stimulated luminescence (OSL) as a chronometer for surface exposure dating

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Chapot, Melissa S.

    2012-01-01

    We pioneer a technique of surface-exposure dating based upon the characteristic form of an optically stimulated luminescence (OSL) bleaching profile beneath a rock surface; this evolves as a function of depth and time. As a field illustration of this new method, the maximum age of a premier example...... exposure histories; one of these samples was exposed at the time of sampling and one was buried and no longer light exposed. A third sample is known to have been first exposed 80 years ago and was still exposed at the time of sampling. First, the OSL-depth profile of the known-age sample is modeled...... to estimate material-dependent and environmental parameters. These parameters are then used to fit the model to the corresponding data for the samples of unknown exposure history. From these fits we calculate that the buried sample was light exposed for similar to 700 years before burial and that the unburied...

  12. Thermoluminescence characteristics and dating of some egyptian rocks using gamma-rays

    International Nuclear Information System (INIS)

    Sharaf, M.M.; Mohamed, R.I.; Rabie, N.

    1994-01-01

    The thermoluminescence (T L) characteristics and dating of some natural samples which were collected from different areas in the eastern desert of egypt have been studied. The T L- glow curves of all natural samples show three peaks, shallow peak, dosimetric peak and dating peak. T L response to gamma rays for the samples under examination shows a linear response from 4.5 Gy up to 7.5 kGy followed by saturation. Ages of these geological rocks from the selected areas A (hutait), B(Urga), C(Tendba), D(Sebaya) and E(Atad) in the Eastern desert were found to be 4 X 108, 1.5 X 109, 0.5 X 108, 2.5 X 107 and 3 X 107 years, respectively. It can be concluded that these geological rocks belong to the precambrian period of the history. 4 figs., 4 tabs

  13. Thermoluminescence characteristics and dating of some egyptian rocks using gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Sharaf, M M; Mohamed, R I; Rabie, N [Acodemy of Scientific Research and Technology, National Institute for Standards, Pyramids, Giza (Egypt)

    1994-12-31

    The thermoluminescence (T L) characteristics and dating of some natural samples which were collected from different areas in the eastern desert of egypt have been studied. The T L- glow curves of all natural samples show three peaks, shallow peak, dosimetric peak and dating peak. T L response to gamma rays for the samples under examination shows a linear response from 4.5 Gy up to 7.5 kGy followed by saturation. Ages of these geological rocks from the selected areas A (hutait), B(Urga), C(Tendba), D(Sebaya) and E(Atad) in the Eastern desert were found to be 4 X 108, 1.5 X 109, 0.5 X 108, 2.5 X 107 and 3 X 107 years, respectively. It can be concluded that these geological rocks belong to the precambrian period of the history. 4 figs., 4 tabs.

  14. Dating of pre-exposure times of lunar rocks and soils

    International Nuclear Information System (INIS)

    Eugster, O.

    1986-01-01

    Xenon produced by fission of uranium, thorium and plutonium has repeatedly been observed in lunar rocks and soils. In two basaltic rocks and in two soils Xe was found originating from fission of U-235 induced by neutrons which are due to the interactions of cosmic ray particles with lunar matter. Two facts lead to this conclusion: (1) fission Xe is present in excess of that expected for the U, Th, and Pu concentrations and for the gas retention age of the samples; and (2) the Xe-134/Xe-136 ratio of excess fission Xe is close to 1.25 as expected for neutron induced fission of U-235. Information on the duration of the exposure to cosmic rays was obtained from the Kr-81-Kr systematics whereas the effective shielding conditions were derived from the depth sensitive cosmogenic ratio Xe-131/Xe-126. For the four samples the exposure to cosmic rays in the lunar regolith is described by a two stage exposure model. The history of the four samples was derived in terms of duration and shielding depth of the two stages

  15. Cosmic ray exposure in aircraft and space flight

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Sugiura, Nobuyuki; Iimoto, Takeshi

    2000-01-01

    The exposure from cosmic ray radiation to the workers and public is a new aspect of exposure that was cased by the development of science and technology. ICRP Publication 60 says: 'to provide some practical guidance, the Commission recommends that there should be a requirement to include exposure to natural sources as part of occupational exposure only in the following cases: radon..., some natural radionuclides..., operation of jet air craft, space flight'. For this situation what kind of radiation protection concept is applicable? And what kind of radiation guideline and procedure are possible to propose? Here, we would like to review the past activities on this issue and to summarize the concepts in ICRP concerning to these exposure. Then the recommended radiation protection system will be proposed as one trial to this solution. In the paper the characters of cosmic ray were firstly reviewed. Cosmic rays are consisted by solar one and galactic one. Both of them have high energy and this will cause the difficulty of dosimetry because of lacking of physical and biological data. Next discussion point is a classification of exposure. For this, several classifications were done: jet airplane flight, supersonic airplane flight and space flight. Other classification is aircrew (occupational exposure), passengers (public exposure), frequent flyers (gray zone), space astronauts (special mission), and pregnant women. Considering the real level of radiation the practical radiation control is proposed including the cosmic radiation exposure prediction method by computer codes. The discussion of space astronauts is a little different for the highness of radiation doses. The dose levels will be obtained through the discussion of lifetime risk balancing their mission importance. (author)

  16. In Situ Radiometric and Exposure Age Dating of the Martian Surface

    Science.gov (United States)

    Farley, K. A.; Malespin, C.; Mahaffy, P.; Grotzinger, J. P.; Vasconcelos, P. M.; Milliken, R. E.; Malin, M.; Edgett, K. S.; Pavlov, A. A.; Hurowitz, J. A.; hide

    2014-01-01

    We determined radiogenic and cosmogenic noble gases in a mudstone on the floor of Gale Crater. A K-Ar age of 4.21 +/- 0.35 billion years represents a mixture of detrital and authigenic components and confirms the expected antiquity of rocks comprising the crater rim. Cosmic-ray-produced 3He, 21Ne, and 36Ar yield concordant surface exposure ages of 78 T 30 million years. Surface exposure occurred mainly in the present geomorphic setting rather than during primary erosion and transport. Our observations are consistent with mudstone deposition shortly after the Gale impact or possibly in a later event of rapid erosion and deposition. The mudstone remained buried until recent exposure by wind-driven scarp retreat. Sedimentary rocks exposed by this mechanism may thus offer the best potential for organic biomarker preservation against destruction by cosmic radiation.

  17. Accidental over-exposure from dental X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, B G [National Radiological Protection Board, Harwell (UK)

    1976-07-01

    A description is given of an unusual dental X-ray procedure which resulted in accidental over-exposure both to the dentist and to several of his patients when a short-circuit was present in newly-installed equipment. The short-circuit by-passed the exposure control and energized the tube for certain orientations of the X-ray tube. The dentist left the patients, who wore protective aprons, to initiate the exposure themselves, using the control button. Although the warning lights were on, the dentist was not present in the room during the exposure, and the over-exposures were only detected when the developed X-ray films were found to be completely blackened. A reconstruction of the procedure enabled estimates to be made of the dose equivalents to the dentist's body and to the skin of the head, the eyes and the gonads of the patients. The dentist had overlooked several of basic principles recommended in the Code of Practice for the Protection of Persons against Ionizing Radiations from Medical and Dental Use (1972). It is pointed out that incidents involving failure of dental equipment (usually the timer mechanism) are not infrequent.

  18. Calculation of gamma ray exposure rates from uranium ore bodies

    International Nuclear Information System (INIS)

    Thomson, J.E.; Wilson, O.J.

    1980-02-01

    The planning of operations associated with uranium mines often requires that estimates be made of the exposure rates from various ore bodies. A straight-forward method of calculating the exposure rate from an arbitrarily shaped body is presented. Parameters for the calculation are evaluated under the assumption of secular equilibrium of uranium with its daughters and that the uranium is uniformly distributed throughout an average soil mixture. The spectral distribution of the emitted gamma rays and the effect of air attenuation are discussed. Worked examples are given of typical situations encountered in uranium mines

  19. Constancy of radiation output during diagnostic X-ray exposures

    International Nuclear Information System (INIS)

    Ardran, G.M.; Crooks, H.E.; Birch, R.

    1978-01-01

    Variation in X-ray output and quality during a diagnostic exposure can be undesirable and may result in unnecessary dose to the patient. When significant build-up or decay periods are present errors will arise if factors obtained under steady-state conditions are employed to estimate the exposure. These parameters must be taken into account when calibrating X-ray generators. A variable speed spinning film device and a spectrometry system have been used to measure the variations under fluoroscopic and radiographic conditions for a number of generators. Variations in output due to filament heating, voltage supply and rectification, cable capacity and target pitting have been demonstrated. At low fluoroscopic currents, large surges and long decays have been observed; the significance of these effects is considered. (author)

  20. Radiation exposure in X-ray studies of the hips

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F [Krankenhaus der Barmherzigen Brueder, Salzburg (Austria). Roentgeninstitut

    1979-12-01

    The genetic exposure of the small child is above all a consequence of the rapid increase in X-ray studies, a problem which has not yet been settled. Through phantom measurements it can be shown, that dose reduction is of considerable practical significance if appropriate lead shielding is employed. The radiation dose can be significantly reduced, provided that the shielding material is of an appropriate lead equivalent. The form of the pelvic shield which is used is also of crucial importance.

  1. Prenatal x-ray exposure and childhood cancer in twins

    International Nuclear Information System (INIS)

    Harvey, E.B.; Boice, J.D. Jr.; Honeyman, M.; Flannery, J.T.

    1985-01-01

    A case-control study was conducted to investigate the relation between prenatal exposure to x-rays and childhood cancer, including leukemia, in over 32,000 twins born in Connecticut from 1930 to 1969. Twins as opposed to single births were chosen for study to reduce the likelihood of medical selection bias, since twins were often exposed to x-rays to diagnose the twin pregnancy or to determine fetal positioning before delivery and not because of medical conditions that may conceivably pre-dispose to cancer. Each of 31 incident cases of cancer, identified by linking the Connecticut twin and tumor registries, was matched with four twin controls according to sex, year of birth, and race. Records of hospitals, radiologists, and private physicians were searched for histories of x-ray exposure and other potentially important risk factors. Documented prenatal x-ray exposures were found for 39 per cent of the cases (12 of 31) and for 26 per cent of the controls (28 of 109). No other pregnancy, delivery, or maternal conditions were associated with cancer risk except low birth weight: 38 per cent of the cases as compared with 25 per cent of the controls weighed under 2.27 kg at birth. When birth weight was adjusted for, twins in whom leukemia or other childhood cancer developed were twice as likely to have been exposed to x-rays in utero as twins who were free of disease (relative risk, 2.4; 95 per cent confidence interval, 1.0 to 5.9). The results, though based on small numbers, provide further evidence that low-dose prenatal irradiation may increase the risk of childhood cancer

  2. Acute behavioural dysfunctions following exposure to γ-rays

    International Nuclear Information System (INIS)

    Kumar, Mayank; Haridas, Seenu; Manda, Kailash

    2014-01-01

    Exposure to ionizing radiations (IR) has been reported to have many ill effects. These are manifested immediately after exposure and may persist or develop long after the incident. The severity and manifestation is dependent on the absorbed dose and type of the IR. These have been reported extensively in human subjects; especially among the victims of the accidental exposure and radiotherapy patients. Additionally, there have been a plethora of studies in animal models which support these findings, and are being used to test radio-mitigative or radio-protective strategies. The vulnerability of neuronal tissue to IR is well known, however the acute dose-dependent behavioural consequences have yet to be understood. Thus, our laboratory has been trying to decipher the dose-dependent behavioural dysfunctions which have occurred 24-72 hours post IR exposure and possible radio-protective strategies. We are utilizing mouse models of studying the behavioural processes, in a test battery conceptualized to study the affective and cognitive skills as well as motor skills of the animals. Additionally, we have observed cellular damage to different areas of the brain and subsequent correlations to behavioural dysfunctions. This has being carried out by using single cell gel electrophoresis (SCGE) and Diffusion Tensor Imaging (DTI). The findings show that after exposure to sub-lethal γ-rays, there are significant changes that occur in all the behavioural parameters. The most sensitive area has been found to be the Hippocampus as visualized by DTI and the SCGE. Consequently, short term and long term memory functions have been shown to be disrupted within 24-72 hours of exposure. Acute dysfunctions of affective functions have also been demonstrated to materialise within 24 hours post exposure. Unexpectedly, the behavioural dysfunctions were seen to be dose independent. Thus, this study provides a foundation to help decipher the acute behavioural manifestations of IR exposure

  3. Cosmogenic Nuclide Exposure Dating of the Tiltill Rock Avalanche, Yosemite National Park

    Science.gov (United States)

    Ford, K. R.; Pluhar, C. J.; Stone, J. O.; Stock, G. M.; Zimmerman, S. R.

    2013-12-01

    Yosemite National Park serves as an excellent natural laboratory for studying rock falls and rock avalanches because these are the main processes modifying the nearly vertical slopes of this recently glaciated landscape. Mass wasting represents a significant hazard in the region and the database of previous rock falls and other mass wasting events in Yosemite is extensive, dating back to the mid-1800s. However, this record is too short to capture the recurrence characteristics and triggering mechanisms of the very largest events, necessitating studies of the geologic record of mass wasting. Rock falls and rock avalanches are readily dated by cosmogenic nuclide methods due to their instantaneous formation, and results can be tied to triggering events such as seismic activity (e.g. Stock et al., 2009). Here, we apply exposure dating to the Holocene Tiltill rock avalanche north of Hetch Hetchy Reservoir. The deposit comprises what appear to be two separate lobes of rock and debris, yielding a total volume of ~3.1 x 106 m3. Assuming an erosion rate of 0.0006 cm/yr and neglecting snowpack shielding, preliminary data suggest a mean exposure age of 11,000 + 600 year B.P. for both deposits, indicating that they were emplaced in a single event. The age of the Tiltill 'slide' is similar to earthquakes on the Owens Valley Fault between 10,800 + 600 and 10,200 + 200 cal year B.P. (Bacon, 2007) and the White Mountain Fault, ~10,000 cal year B.P. (Reheis, 1996; DePolo, 1989). Given that movement on the Owens Valley fault in 1872 caused a number of rock falls in Yosemite and the coincidence of ages between the Tiltill 'slide' and paleoseismic events, a large earthquake in Eastern Sierra Nevada may have triggered this event. Other trigger events are also possibilities, but only through compilation of a database of large rock avalanches can statistically significant groupings of events begin to demonstrate whether seismic triggering is a dominant process.

  4. Computer program for diagnostic X-ray exposure conversion

    International Nuclear Information System (INIS)

    Lewis, S.L.

    1984-01-01

    Presented is a computer program designed to convert any given set of diagnostic X-ray exposure factors sequentially into another, yielding either an equivalent photographic density or one increased or decreased by a specifiable proportion. In addition to containing the wherewithal with which to manipulate a set of exposure factors, the facility to print hard (paper) copy is included enabling the results to be pasted into a notebook and used at any time. This program was originally written as an investigative exercise into examining the potential use of computers for practical radiographic purposes as conventionally encountered. At the same time, its possible use as an educational tool was borne in mind. To these ends, the current version of this program may be used as a means whereby exposure factors used in a diagnostic department may be altered to suit a particular requirement or may be used in the school as a mathematical model to describe the behaviour of exposure factors under manipulation without patient exposure. (author)

  5. Implementation of a primary standard for x-ray exposure

    International Nuclear Information System (INIS)

    Peixoto, Jose Guilherme Pereira

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-ray s of 10OKV to 250kV of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Since the collecting rod is small, and positioned far away from the X-ray beam, only a negligible fraction of ionization (0,01 %) is lost due to interactions with it. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation , beam homogeneity, influence Of beam size and influences of temperature, humidity and atmospheric pressure.Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  6. Radiation exposure with the NOMAD portable X-ray system.

    Science.gov (United States)

    Goren, A D; Bonvento, M; Biernacki, J; Colosi, D C

    2008-02-01

    A new hand-held battery-operated portable X-ray system was tested for possible leakage radiation through the existing heavy metal compounds surrounding the X-ray tube, backscatter radiation through the lead-filled acrylic shield attached at the end of the exit tube and patient exposure. Dose measurements were conducted using a DXTRR phantom and a water phantom. All measurements were recorded using calibrated thermoluminescent dosimetry (TLD), calibrated Unfors Model 583L dosemeter, and a calibrated Radcal MDH model 1015 dosemeter. The settings for all exposure were 60 kVp, 2.3 mA and 0.25 s using Kodak Insight (Class F) film. All backscatter measurements, in front of the shield, behind the shield, at the finger of the operator, the operator's chest, eyes and gonads were significantly below the maximum permissible radiation leakage as per the United States Food and Drug Administration regulations (100 mR h(-1)). Our measurements indicate that the exposure would be well within the occupational maximum permissible dose for an occupationally exposed person. Film dose was consistent with the manufacturer's recommendations. As a result of our measurements, the State of New York Bureau of Environmental Radiation Protection granted us a variance to use the NOMAD on a case-by-case basis. Our data have shown that the NOMAD presents risks that are no greater than with standard dental radiographic units to the patient or operator and the measured doses are well below recommended levels.

  7. Effect of gamma rays on fruit storage of some date palm cultivars

    International Nuclear Information System (INIS)

    El Salhy, F.T.A.

    1998-01-01

    This investigation wa conducted on two date groups: Semi-dry date (Amry cultivar) and dry date (Sackoti and Bartamoda cultivars) dates, at the National Center for Radiation Research and Technology (NCRRT), in Cairo, during two successive seasons, 1992 and 1993. The aim of this study is to find out the best alternative method for improving fruit quality as well as prolonging the marketable period of date fruits. Semi-dry date (Amry) fruits were obtained from El-Kourain region, brought from Aswan Governorate. Two hundred and twenty kilograms of fruits from each date group were collected to be used for the different postharvest experiments

  8. Accidental exposure with X-ray diffraction equipment

    International Nuclear Information System (INIS)

    Montanez, O.; Blanco, D.

    1991-01-01

    The shutter on one of the windows of an X-ray diffraction apparatus was accidentally left open, exposing the worker to the radiation. The worker was wearing a dosimeter film, which was processed immediately to evaluate the potential risk. It was determined that the exposure rate was 350 Roentgen/minute on the skin surface, with corrections being made for the worker's thin clothing. It was concluded that in spite of the worker receiving a relative high dose, it did not reach the threshold value for producing deterministic effects such as cataracts, erythema, and skin damage

  9. Radiation exposure in X-ray examinations of the pelvis

    International Nuclear Information System (INIS)

    Kainberger, F.

    1977-01-01

    The article reports on radiation exposure during X-ray treatment of the pelvis of children. Special attention is paid to genetical radiation exposure. Generally a dose of 100 mR is assumed to be taken up if no adequate shielding is provided. In order to be able to judge the value of a shielding with suitable lead-equivalent values, measurements were carried out on a phantom. These measurements showed that the dosage can be reduced by at least a factor 100 by using a lead shielding. When doing this, the lead equivalent value must be 1 mm. The form of gonad protection also has great importance for the shielding efficiency. (orig.) [de

  10. Cytogenetic studies with laser or X-ray exposures

    International Nuclear Information System (INIS)

    Bozduganov, A.; Genkov, P.

    1975-01-01

    Account is given of studies involving a total of 21 peripheral blood cultures given the following treatments: exposure to 20 0.13-joule pulses from an optic quantum generator (ruby), 9; exposure to 1000 R X-rays, 9; and unexposed controls, 3. Exposures were carried out on three cultures from each experimental series at each of three time intervals, namely 24 h, 48 h, and 72 h after initiation of cultures. On any day, 40 well-spread metaphases were examined. High quality metaphases were photographed and karyotyped in conformity to the Chicago Conference criteria. In the laser experiment, chromosome aberrations were observed in 65% of methaphases analyzed vs. 5.3% in controls. Anomalies encountered included aneuploidy, with hypoploid metaphases predominating, polyploidy (triploidy, tetraploidy, and partial endoreduplication), and structural alterations. The following structural chromosome rearrangements are found: acentric fragments, mostly pairs, occasionally single, including minute chromosomes; dicentric and tricentric chromosomes; interstitial deletions; and chromosome translocations. Most varied and abundant chromosome aberrations were seen in 72-h irradiated cultures. The data presented offer a new opportunity for assessing genetic lesions after laser exposure and may help to determine threshold doses. (author)

  11. Radiocarbon-dates of snow petrel regurgitations can reveal exposure periods for nunataks in Antarctica

    CSIR Research Space (South Africa)

    Ryan, PG

    1992-11-01

    Full Text Available There are several problems associated with determining radiocarbon dates, particularly for organic material from Antarctica. However, this study attempts to find accurate measure of the length of time these radiocarbon dates have been established...

  12. A dated molecular phylogeny of manta and devil rays (Mobulidae) based on mitogenome and nuclear sequences.

    Science.gov (United States)

    Poortvliet, Marloes; Olsen, Jeanine L; Croll, Donald A; Bernardi, Giacomo; Newton, Kelly; Kollias, Spyros; O'Sullivan, John; Fernando, Daniel; Stevens, Guy; Galván Magaña, Felipe; Seret, Bernard; Wintner, Sabine; Hoarau, Galice

    2015-02-01

    Manta and devil rays are an iconic group of globally distributed pelagic filter feeders, yet their evolutionary history remains enigmatic. We employed next generation sequencing of mitogenomes for nine of the 11 recognized species and two outgroups; as well as additional Sanger sequencing of two mitochondrial and two nuclear genes in an extended taxon sampling set. Analysis of the mitogenome coding regions in a Maximum Likelihood and Bayesian framework provided a well-resolved phylogeny. The deepest divergences distinguished three clades with high support, one containing Manta birostris, Manta alfredi, Mobula tarapacana, Mobula japanica and Mobula mobular; one containing Mobula kuhlii, Mobula eregoodootenkee and Mobula thurstoni; and one containing Mobula munkiana, Mobula hypostoma and Mobula rochebrunei. Mobula remains paraphyletic with the inclusion of Manta, a result that is in agreement with previous studies based on molecular and morphological data. A fossil-calibrated Bayesian random local clock analysis suggests that mobulids diverged from Rhinoptera around 30 Mya. Subsequent divergences are characterized by long internodes followed by short bursts of speciation extending from an initial episode of divergence in the Early and Middle Miocene (19-17 Mya) to a second episode during the Pliocene and Pleistocene (3.6 Mya - recent). Estimates of divergence dates overlap significantly with periods of global warming, during which upwelling intensity - and related high primary productivity in upwelling regions - decreased markedly. These periods are hypothesized to have led to fragmentation and isolation of feeding regions leading to possible regional extinctions, as well as the promotion of allopatric speciation. The closely shared evolutionary history of mobulids in combination with ongoing threats from fisheries and climate change effects on upwelling and food supply, reinforces the case for greater protection of this charismatic family of pelagic filter feeders

  13. Effects of Cognitive Distortions on the Link Between Dating Violence Exposure and Substance Problems in Clinically Hospitalized Youth.

    Science.gov (United States)

    Miller, Adam Bryant; Williams, Caitlin; Day, Catherine; Esposito-Smythers, Christianne

    2017-06-01

    The purpose of the present study was to examine whether cognitive distortions (e.g., cognitive errors; negative views of self, world, and future) influence the association between dating violence and problematic substance use behaviors in a sample of psychiatrically hospitalized adolescents. Participants included 155 adolescents, aged 13-17 years, who had initiated dating. Adolescents completed measures of dating violence, substance-related problems (alcohol and marijuana), and cognitive distortions. Logistic regressions were conducted to examine the direct and interactive effects of dating violence exposure and cognitive distortions on likelihood of recent problematic substance use. Results suggested a main effect of dating violence on problematic alcohol and other drug use as well as an interactive effect of dating violence and cognitive distortions. Specifically, the relationship between dating violence and odds of substance-related problems was higher among those with greater (vs. fewer) cognitive distortions. Study results suggest the need for careful screening of cognitive distortions among adolescent dating violence victims, particularly those in mental health treatment. © 2016 Wiley Periodicals, Inc.

  14. Contribution of cosmic rays to radiation exposure of the population

    International Nuclear Information System (INIS)

    Sztanyik, L.B.; Nikl, I.

    1982-01-01

    To evaluate the exposure of the Hungarian population to cosmic rays, the absorbed dose rate in air of cosmic radiation was directly measured by high pressure ionization chamber at ground level on the surface of different bodies of water and at various altitudes on the board of an aircraft. From the dose rates measured this way, the outdoor dose equivalent rate from the ionizing components of cosmic radiation to people living at sea level would be 300-325 μSv per year. Taking into account the altitude distribution of the population, the average weighted dose equivalent is about 320 μSv per year. At Kekestetoe, the highest peak of the Matra Mountains, (the highest altitude in Hungary), the annual dose equivalent is about 50 per cent higher than on the Great Hungarian Plain. (author)

  15. Adolescent Conflict as a Developmental Process in the Prospective Pathway from Exposure to Interparental Violence to Dating Violence

    Science.gov (United States)

    Narayan, Angela J.; Englund, Michelle M.; Carlson, Elizabeth A.; Egeland, Byron

    2013-01-01

    Within a developmental psychopathology framework, the current study examined adolescent conflict (age 16) with families, best friends, and dating partners as mediators in the prospective pathway from exposure to interparental violence (EIPV) in early childhood (0–64 months) to dating violence perpetration and victimization in early adulthood (age 23). Adolescent conflict was predicted to partially mediate EIPV and dating violence with significant direct paths from EIPV to dating violence, given the extant literature on the salience of early childhood EIPV for later maladjustment. Participants (N = 182; 99 males, 83 females; 67% Caucasian, 11% African-American, 18% other, 4% unreported) were drawn from a larger prospective study of high-risk mothers (aged 12–34 years) that followed their children from birth through adulthood. EIPV and adolescent conflict were rated from interviews with mothers and participants, and dating violence (physical perpetration and victimization) was assessed with the Conflict Tactics Scale. Path analyses showed that EIPV in early childhood (a) directly predicted dating violence perpetration in early adulthood and (b) predicted conflict with best friends, which in turn predicted dating violence perpetration. Although mediation of best friend conflict was not evident, indirect effects of EIPV to dating violence were found through externalizing behaviors in adolescence and life stress in early adulthood. Findings highlight that conflict with best friends is affected by EIPV and predicts dating violence, suggesting that it may be a promising target for relationship-based interventions for youth with EIPV histories. Furthermore, deleterious early experiences and contemporaneous risk factors are salient predictors of dating violence. PMID:23979004

  16. Medical management of severe local radiation injury after acute X-ray exposure

    International Nuclear Information System (INIS)

    Bushmanov, A.; Nadezhina, N.; Kretov, A.

    2008-01-01

    Medical management during acute period in a case of severe local radiation injury after acute X-ray exposure includes 3 stages. During the fist stage patient got conservative treatment according to the common pathogenetic mechanisms of LRI (dis aggregating therapy, stimulation of regeneration, dis intoxication therapy, antibiotic therapy, pain relief therapy, Local anti-burn therapy-specific non-adhesive bandage with antiseptic and anti-burn medicaments); estimation of severity, deepness and area of injury by clinical picture and dates of instrumental methods of examining; defining necessity and volume of surgical treatment; preparing arrangements for surgical treatment. This stage ends with forming of demarcation line of a very hard severity of a Local Radiation Injure. The second stage includes necrectomy of the area of a very hard severity with microsurgical plastic by re vascularized flap and auto dermoplastic. The third stage - adaptation of re vascularized flap and total epithelization of injured area. (author)

  17. Differences of X-ray exposure between X-ray diagnostics with a conventional X-ray screen-system and with an image-intensifier-television-unit

    International Nuclear Information System (INIS)

    Loehr, H.; Vogel, H.; Reinhart, J.; Jantzen, R.

    1977-01-01

    During X-ray diagnostics of patients in the II. Medizinische Poliklinik the X-ray exposure was determined. It corresponded to the data described in literature. Two groups were compared: 518 patients examined with a conventional X-ray screen-system and 642 patients examined with an image-intensifier-television-system. The results demonstrated that with exception of thoracical X-ray examination the replacing of the old system by the television system brought a remarkable increase of the X-ray exposure. The doses depended of the patients constitution to a high degree. (orig.) [de

  18. Direct dating of Tantavel man by non-destructive gamma-ray spectrometry of fossil human skull Arago XXI

    International Nuclear Information System (INIS)

    Yokoyama, Yuji; Nguyen, Huu-Van

    1981-01-01

    A new method to date prehistoric samples is proposed. Non-destructive gamma-ray spectrometry with semi-conductor detector was used in the direct determination of the activities of 238 U, 234 U, 231 Pa, 230 Th and 228 Th. An age of (400sub(-96)sup(+infinite))x10 3 years was obtained from the 230 Th/ 238 U ratio of 0.975+-0.030 [fr

  19. A study on the wine-date preservation using Co-60 γ ray

    International Nuclear Information System (INIS)

    Li Guozhu; Hao Xiaoling

    1993-01-01

    Wine-dates go mouldy when they are processed on a large scale and transported, and farmers suffer heavy losses. Dates were treated with 5 different radiation doses repeated six times, and then the dates were kept in a temperature of 18-21 o C. The results showed that irradiation with 1.5-6.0 kGy kills the germs and moulds on date cuticles, the number of bacteria decreases with the increasing dose, and they can be kept in store for more days. Nutritive components, such as carbohydrates, vegetable fats, proteins, amino-acids and microelements etc. are not affected. Under the condition of our experiments, the optimum irradiation dose, when stored 10 days, is 3.0 kGy and 6.0 kGy when stored 90 days. (author)

  20. Developmental Timing and Continuity of Exposure to Interparental Violence and Externalizing Behavior as Prospective Predictors of Dating Violence

    Science.gov (United States)

    Narayan, Angela J.; Englund, Michelle M.; Egeland, Byron

    2014-01-01

    This study investigated the prospective pathways of children's exposure to interparental violence (EIPV) in early and middle childhood and externalizing behavior in middle childhood and adolescence as developmental predictors of dating violence perpetration and victimization at ages 23 and 26 years. Participants (N = 168) were drawn from a longitudinal study of low-income families. Path analyses examined whether timing or continuity of EIPV predicted dating violence and whether timing or continuity of externalizing behavior mediated these pathways. Results indicated that EIPV in early childhood directly predicted perpetration and victimization at age 23. There were significant indirect effects from EIPV to dating violence through externalizing behavior in adolescence and life stress at age 23. Independent of EIPV, externalizing behavior in middle childhood also predicted dating violence through externalizing behavior in adolescence and life stress at age 23, but this pathway stemmed from maltreatment. These results highlight that the timing of EIPV and both the timing and continuity of externalizing behavior are critical risks for the intergenerational transmission of dating violence. Findings support a developmental perspective that negative early experiences and children's externalizing behavior are powerful influences for dating violence in early adulthood. PMID:24229543

  1. Developmental timing and continuity of exposure to interparental violence and externalizing behavior as prospective predictors of dating violence.

    Science.gov (United States)

    Narayan, Angela J; Englund, Michelle M; Egeland, Byron

    2013-11-01

    This study investigated the prospective pathways of children's exposure to interparental violence (EIPV) in early and middle childhood and externalizing behavior in middle childhood and adolescence as developmental predictors of dating violence perpetration and victimization at ages 23 and 26 years. Participants (N = 168) were drawn from a longitudinal study of low-income families. Path analyses examined whether timing or continuity of EIPV predicted dating violence and whether timing or continuity of externalizing behavior mediated these pathways. Results indicated that EIPV in early childhood directly predicted perpetration and victimization at age 23. There were significant indirect effects from EIPV to dating violence through externalizing behavior in adolescence and life stress at age 23. Independent of EIPV, externalizing behavior in middle childhood also predicted dating violence through externalizing behavior in adolescence and life stress at age 23, but this pathway stemmed from maltreatment. These results highlight that the timing of EIPV and both the timing and the continuity of externalizing behavior are critical risks for the intergenerational transmission of dating violence. The findings support a developmental perspective that negative early experiences and children's externalizing behavior are powerful influences for dating violence in early adulthood.

  2. Th/U/Pu/Cm dating of galactic cosmic rays with the extremely heavy cosmic ray composition observer

    Science.gov (United States)

    Westphal, Andrew J.; Weaver, Benjamin A.; Tarlé, Gregory

    The principal goal of ECCO, the Extremely-heavy Cosmic-ray Composition Observer, is the measurement of the age of heavy galactic cosmic-ray nuclei using the extremely rare actinides (Th, U, Pu, Cm) as clocks. ECCO is one of two cosmic-ray instruments comprising the Heavy Nuclei Explorer (HNX), which was recently selected as one of several missions for Phase A study under NASA's Small class Explorer (SMEX) program. ECCO is based on the flight heritage of Trek, an array of barium-phosphate glass tracketch detectors deployed on the Russian space station Mir from 1991-1995. Using Trek, we measured the abundances of elements with Z > 70 in the galactic cosmic rays (GCRs). Trek consisted of a 1 m 2 array of stacks of individually polished thin BP-1 glass detectors. ECCO will be a much larger instrument, but will achieve both excellent resolution and low cost through use of a novel detector configuration. Here we report the results of recent accelerator tests of the ECCO detectors that verify detector performance. We also show the expected charge and energy resolution of ECCO as a function of energy.

  3. LGM and Late Glacial glacier advances in the Cordillera Real and Cochabamba (Bolivia deduced from 10Be surface exposure dating

    Directory of Open Access Journals (Sweden)

    H. Veit

    2007-10-01

    Full Text Available Surface exposure dating (SED is an innovative tool already being widely applied for moraine dating and for Late Quaternary glacier and climate reconstruction. Here we present exposure ages of 28 boulders from the Cordillera Real and the Cordillera Cochabamba, Bolivia. Our results indicate that the local Last Glacial Maximum (LGM in the Eastern Cordilleras occurred at ~22–25 ka and was thus synchronous to the global temperature minimum. We were also able to date several Late Glacial moraines to ~11–13 ka, which likely document lower temperatures and increased precipitation ("Coipasa" humid phase. Additionally, we recognize the existence of older Late Glacial moraines re-calculated to ~15 ka from published cosmogenic nuclide data. Those may coincide with the cold Heinrich 1 event in the North Atlantic region and the pronounced "Tauca" humid phase. We conclude that (i exposure ages in the tropical Andes may have been overestimated so far due to methodological uncertainties, and (ii although precipitation plays an important role for glacier mass balances in the tropical Andes, it becomes the dominant forcing for glaciation only in the drier and thus more precipitation-sensitive regions farther west and south.

  4. A study on the wine-date preservation using Co-60 γ ray

    Science.gov (United States)

    Guozhu, Li; Xiaoling, Hao

    1993-07-01

    The wine-dates go mouldy seriously when they are processed in a large scale and transported, from which farmers suffer heavy losses. In this paper, we treated dates with 5 different rediation dosages, and repeated them six times, and then kept the dates in the temperature of 18-21°C. The resultes showed that the irradiation with 1.5-6.0 kGy is very effective to kill the germs and moulds on dates cuticles, the number of bacteria decreases with the dosages increasing, and can keep them in store for more days. The analysis of variance and F- test indicated, that the days of preservation prolonged and the number of infected mildew in the tenth day treated with the dosage above 1.5 kGy compared with check are both achieved 0.01 significant level. But the nutritive components, such as carbohydrates, vegetable fats, proteins, amino-acides and microelements etc. have no obvious difference. Under the condition of our experiments, the optimum irradiation dose, when stored 10 days, is 3.0 kGy and 6.0 kGy when stored 90 days.

  5. Cosmic-ray interactions and dating of meteorite stranding surfaces with cosmogenic nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Reedy, R.C.

    1988-01-01

    A wide variety of products from cosmic-ray interactions have been measured in terrestrial or extraterrestrial samples. These ''cosmogenic'' products include radiation damage tracks and rare nuclides that are made by nuclear reactions. They often have been used to determine the fluxes and composition of cosmic-ray particles in the past, but they are usually used to study the history of the ''target'' (such as the time period that it was exposed to cosmic-ray particles). Products made by both the high-energy galactic cosmic rays and energetic particles emitted irregularly from the Sun have been extensively studied. Some of these cosmogenic products, especially nuclides, have been or can be applied to studies of Antarctic meteorite stranding surfaces, the ice surfaces in Antarctica where meteorites have been found. Cosmogenic nuclides studied in samples from Antarctica and reported by others elsewhere in this volume include those in meteorites, especially radionuclides used to determine terrestrial ages, and those made in situ in terrestrial rocks. Cosmogenic nuclides made in the Earth's atmosphere or brought in with cosmic dust have also been studied in polar ice, and it should also be possible to measure nuclides made in situ in ice. As an introduction to cosmogenic nuclides and their applications, cosmic rays and their interactions will be presented below and production systematics of cosmogenic nuclides in these various media will be discussed later. 20 refs., 2 tabs.

  6. Cosmic-ray interactions and dating of meteorite stranding surfaces with cosmogenic nuclides

    International Nuclear Information System (INIS)

    Reedy, R.C.

    1988-01-01

    A wide variety of products from cosmic-ray interactions have been measured in terrestrial or extraterrestrial samples. These ''cosmogenic'' products include radiation damage tracks and rare nuclides that are made by nuclear reactions. They often have been used to determine the fluxes and composition of cosmic-ray particles in the past, but they are usually used to study the history of the ''target'' (such as the time period that it was exposed to cosmic-ray particles). Products made by both the high-energy galactic cosmic rays and energetic particles emitted irregularly from the Sun have been extensively studied. Some of these cosmogenic products, especially nuclides, have been or can be applied to studies of Antarctic meteorite stranding surfaces, the ice surfaces in Antarctica where meteorites have been found. Cosmogenic nuclides studied in samples from Antarctica and reported by others elsewhere in this volume include those in meteorites, especially radionuclides used to determine terrestrial ages, and those made in situ in terrestrial rocks. Cosmogenic nuclides made in the Earth's atmosphere or brought in with cosmic dust have also been studied in polar ice, and it should also be possible to measure nuclides made in situ in ice. As an introduction to cosmogenic nuclides and their applications, cosmic rays and their interactions will be presented below and production systematics of cosmogenic nuclides in these various media will be discussed later. 20 refs., 2 tabs

  7. A dated molecular phylogeny of manta and devil rays (Mobulidae) based on mitogenome and nuclear sequences

    NARCIS (Netherlands)

    Poortvliet, Marloes; Olsen, Jeanine; Croll, Donald A.; Bernardi, Giacomo; Newton, Kelly; Kollias, Spyros; O'Sullivan, John; Fernando, Daniel; Stevens, Guy; Galván Magaña, Felipe; Seret, Bernard; Wintner, Sabine; Hoarau, Galice

    Manta and devil rays are an iconic group of globally distributed pelagic filter feeders, yet their evolutionary history remains enigmatic. We employed next generation sequencing of mitogenomes for nine of the 11 recognized species and two outgroups; as well as additional Sanger sequencing of two

  8. Exposure to rays and radiation hazards in connection with diagnostic X-ray procedures in children

    International Nuclear Information System (INIS)

    Protzer, K.

    1988-01-01

    In this study, figures and data about radiation exposures for diagnostic purposes are surveyed that were collected in connection with X-ray procedures in children. The data were sorted according to body regions and techniques required for their examination so as to permit separate analyses of procedures in the urogenital tract (intravenous urogramme, micturition cystourethrography), thorax (angiocardiogramme, thoractic aortogramme, examinations using cardiac catheters), gastrointestinal system (fluoroscopy and contrast-enhanced irrigoscopy), pelvis (survey radiography), skull (computed tomography) as well as in miscellaneous group of further origins. The second part of the report discusses the uncertainties surrounding the assessment of radiation hazards and indicated radiation doses. A formula is represented for the calculation of life-time reductions that can be applied to any type of cancer and embraces a number of factors like life expectancy at age X, the patient's age at the time of radiotherapy, the five-year-survival rate for the condition under investigation and the diseased organ. At the end of the study, some methods are pointed out that may be helpful in limiting radiation exposure. (KST) [de

  9. 10Be exposure dating of the timing of Neoglacial glacier advances in the Ecrins-Pelvoux massif, southern French Alps

    Science.gov (United States)

    Le Roy, Melaine; Deline, Philip; Carcaillet, Julien; Schimmelpfennig, Irene; Ermini, Magali; Aster Team

    2017-12-01

    Alpine glacier variations are known to be reliable proxies of Holocene climate. Here, we present a terrestrial cosmogenic nuclide (TCN)-based glacier chronology relying on 24 new 10Be exposure ages, which constrain maximum Neoglacial positions of four small to mid-sized glaciers (Rateau, Lautaret, Bonnepierre and Etages) in the Ecrins-Pelvoux massif, southern French Alps. Glacier advances, marked by (mainly lateral) moraine ridges that are located slightly outboard of the Little Ice Age (LIA, c. 1250-1860 AD) maximum positions, were dated to 4.25 ± 0.44 ka, 3.66 ± 0.09 ka, 2.09 ± 0.10 ka, c. 1.31 ± 0.17 ka and to 0.92 ± 0.02 ka. The '4.2 ka advance', albeit constrained by rather scattered dates, is to our knowledge exposure-dated here for the first time in the Alps. It is considered as one of the first major Neoglacial advance in the western Alps, in agreement with other regional paleoclimatological proxies. We further review Alpine and Northern Hemisphere mid-to-high latitude evidence for climate change and glacier activity concomitant with the '4.2 ka event'. The '2.1 ka advance' was not extensively dated in the Alps and is thought to represent a prominent advance in early Roman times. Other Neoglacial advances dated here match the timing of previously described Alpine Neoglacial events. Our results also suggest that a Neoglacial maximum occurred at Etages Glacier 0.9 ka ago, i.e. during the Medieval Climate Anomaly (MCA, c. 850-1250 AD). At Rateau Glacier, discordant results are thought to reflect exhumation and snow cover of the shortest moraine boulders. Overall, this study highlights the need to combine several sites to develop robust Neoglacial glacier chronologies in order to take into account the variability in moraine deposition pattern and landform obliteration and conservation.

  10. Cosmic rays exposure during aircraft flight (3). Guideline and dose evaluation

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    2007-01-01

    Radiation Council of MEXT drew up the Guideline of Cosmic Ray Exposure Control for Air Crew in 2006. The content of the Guideline and evaluation methods of dose are explained. The Guideline stated five items for Airline Company. It consists of 1) exposure dose control for air crew, 2) evaluation methods of cosmic rays exposure dose of air crew, 3) explanation and education of cosmic rays exposure for air crew, 4) reading, record and store of cosmic rays exposure dose of air crew, and 5) health control of air crew. The doses of four airlines were calculated by the Civil Aeromedical Research Institute (CARI) code and the European Program package for the Calculation of Aviation Route Doses (EPCARD) code. The difference of two codes was about 15 to 25%. Japanese Internet System for Calculation of Aviation Route Doses (JISCAED) has been developed by Japan. (S.Y.)

  11. Design And Measurement Of Radiation Exposure Rates At An X-Ray Diagnostic Radiological Unit

    International Nuclear Information System (INIS)

    Tito-Sutjipto

    2003-01-01

    Every radiation employees suffers radiation exposure risk while doing his job. It is important therefore to investigate the occupational health and safety of radiation employees on its relationship with the design and measurement of radiation exposure rates at an X-ray diagnostic radiological unit in this work, a case study was held on the radiological unit at BP-4 Yogyakarta for patient diagnostics, This research armed to investigate the relationship between the design of radiological unit for X-ray diagnostics and the location of the X-ray machine, based on the distance variable and radiation exposure rate during patient diagnostics. This was performed using radiological unit design data for X-ray diagnostics and the measurement of radiation exposure rates throughout patient diagnostics. The design data can then be used for determining the requirement of primary and secondary shielding materials for radiological unit as well as a calculation basis of radiation exposure rates during patient diagnostics. From the result of the research, it can be concluded that from the occupational health and safety point of view, radiation exposure around the X-ray machines are fairly good, both for the shielding materials in each X-ray room and the radiation exposures received by the workers, because they are far beyond the maximum permittable average limit (16.67 m R/days). (author)

  12. Cosmic-ray exposure ages of six chondritic Almahata Sitta fragments

    Science.gov (United States)

    Riebe, M. E. I.; Welten, K. C.; Meier, M. M. M.; Wieler, R.; Barth, M. I. F.; Ward, D.; Laubenstein, M.; Bischoff, A.; Caffee, M. W.; Nishiizumi, K.; Busemann, H.

    2017-11-01

    The Almahata Sitta strewn field is dominated by ureilites, but contains a large fraction of chondritic fragments of various types. We analyzed stable isotopes of He, Ne, Ar, Kr, and Xe, and the cosmogenic radionuclides 10Be, 26Al, and 36Cl in six chondritic Almahata Sitta fragments (EL6 breccia, EL6, EL3-5, CB, LL4/5, R-like). The cosmic-ray exposure (CRE) ages of five of the six samples have an average of 19.2 ± 3.3 Ma, close to the average of 19.5 ± 2.5 Ma for four ureilites. The cosmogenic radionuclide concentrations in the chondrites indicate a preatmospheric size consistent with Almahata Sitta. This corroborates that Almahata Sitta chondrite samples were part of the same asteroid as the ureilites. However, MS-179 has a lower CRE age of 11.0 ± 1.4 Ma. Further analysis of short-lived radionuclides in fragment MS-179 showed that it fell around the same time, and from an object of similar size as Almahata Sitta, making it almost certain that MS-179 is an Almahata Sitta fragment. Instead, its low CRE age could be due to gas loss, chemical heterogeneity that may have led to an erroneous 21Ne production-rate, or, perhaps most likely, MS-179 could represent the true 4π exposure age of Almahata Sitta (or an upper limit thereof), while all other samples analyzed so far experienced exposure on the parent body of similar lengths. Finally, MS-179 had an extraordinarily high activity of neutron-capture 36Cl, 600 dpm kg-1, the highest activity observed in any meteorite to date, related to a high abundance of the Cl-bearing mineral lawrencite.

  13. Accessing the application of in situ cosmogenic 14C to surface exposure dating of amorphous SiO2

    Science.gov (United States)

    Cesta, J. M.; Goehring, B. M.; Ward, D. J.

    2017-12-01

    We assess the feasibility and utility of in situ cosmogenic 14C as a geochronometer for landforms composed of amorphous SiO2 through the comparison of 14C surface exposure ages to independently determined eruption ages on Obsidian Dome, California. Landforms composed of amorphous SiO2 phases are difficult to date by conventional cosmogenic nuclide methods due to several complications that may arise (e.g., inability to remove meteoric contamination). The onset of an increased understanding of production rates and analytical measurement of in situ 14C in SiO2 provides an opportunity to address this limitation. Obsidian Dome is a 600-year-old phreatomagmatic dome of the Mono-Inyo Craters located in Inyo County, California, and consists of vesicular pumice, obsidian, and rhyolite. Exposure ages from eight obsidian and banded pumice and obsidian surface samples range from 3947 ± 678 to 914 ± 134 years, all significantly older than the accepted radiocarbon age of 650-550 years. δ13C values for the samples range between +2.65‰ and +1.34‰ and show a negative correlation with CO2 yield. The `too old' exposure ages coupled with this negative correlation between δ13C and CO2 yield suggests the incorporation of an atmospheric component of 14C. Measurement of 14C concentrations in shielded, subsurface samples will assist in isolating the atmospheric 14C component and aid in correcting the surface exposure ages.

  14. Effect of fast neutrons and gamma rays treatments on heading date, plant height and tiller number in wheat

    International Nuclear Information System (INIS)

    Arain, M.A.

    1978-01-01

    Homogeneous seeds of six varieties of bread wheat, Triticum aestivum L. (2n = 6x = 42) were treated with fast neutrons and gamma rays. The irradiated seeds along with respective controls were grown in field plots during 1973-74 and heating date, plant height and tiller number studied. Varieties used in the present study varied significantly (P >=0.01) for all the characters. Treatment mean squares were highly significant for plant height and tillers per plant; whereas, the varieties x treatments interaction mean squares were significant only for plant height (P >= 0.05). Irradiated treatments exhibited significant reductions in plant height and tiller number than respective controls. However, heading was delayed among the irradiated material when compared with respective controls. Reduction in plant height was more pronounced after the treatments of gamma rays than the fast neutrons. The maximum and minimum shifts in mean values of these characters were observed in 20 kR (gamma rays) and Nf 300 RADS (fast neutrons) treatments, respectively. (author)

  15. The parameters of X-ray equipment that influence in patient exposure

    International Nuclear Information System (INIS)

    Peixoto, J.E.

    1988-01-01

    The main components of the X-rays equipment and the secondary device for radiodiagnosis examination are showed. The influence of all radiographs parameters in human exposure as tension and current are also analysed. (C.G.C.) [pt

  16. Influence of X-ray exposure on morphologic composition of blood of sheep

    International Nuclear Information System (INIS)

    Tukhtaev, T.M.; Badalov, S.

    1983-01-01

    Present article is devoted influence of X-ray exposure on morphologic composition of blood of sheep. Thus, pathogenetic mechanisms of formation of acute radiation sickness of laboratory animals are studied. The experiments are described.

  17. Deglacial history of the Pensacola Mountains, Antarctica from glacial geomorphology and cosmogenic nuclide surface exposure dating

    Science.gov (United States)

    Bentley, M. J.; Hein, A. S.; Sugden, D. E.; Whitehouse, P. L.; Shanks, R.; Xu, S.; Freeman, S. P. H. T.

    2017-02-01

    The retreat history of the Antarctic Ice Sheet is important for understanding rapid deglaciation, as well as to constrain numerical ice sheet models and ice loading models required for glacial isostatic adjustment modelling. There is particular debate about the extent of grounded ice in the Weddell Sea embayment at the Last Glacial Maximum, and its subsequent deglacial history. Here we provide a new dataset of geomorphological observations and cosmogenic nuclide surface exposure ages of erratic samples that constrain the deglacial history of the Pensacola Mountains, adjacent to the present day Foundation Ice Stream and Academy Glacier in the southern Weddell Sea embayment. We show there is evidence of at least two glaciations, the first of which was relatively old and warm-based, and a more recent cold-based glaciation. During the most recent glaciation ice thickened by at least 450 m in the Williams Hills and at least 380 m on Mt Bragg. Progressive thinning from these sites was well underway by 10 ka BP and ice reached present levels by 2.5 ka BP, and is broadly similar to the relatively modest thinning histories in the southern Ellsworth Mountains. The thinning history is consistent with, but does not mandate, a Late Holocene retreat of the grounding line to a smaller-than-present configuration, as has been recently hypothesized based on ice sheet and glacial isostatic modelling. The data also show that clasts with complex exposure histories are pervasive and that clast recycling is highly site-dependent. These new data provide constraints on a reconstruction of the retreat history of the formerly-expanded Foundation Ice Stream, derived using a numerical flowband model.

  18. Calibration of diagnostic x-ray machines using radiation exposure and radiographic parameters

    International Nuclear Information System (INIS)

    Agba, E.H.; Uloko, P. I.; Tyovenda, A. A.

    2011-01-01

    Calibration of diagnostic x-ray machines using radiation exposure and radiographic parameters of the x-ray machines has been carried out. Three phase diagnostic x-ray machines situated at Federal Medical Centre, Makurdi, General Hospital, Otukpo and Christian Hospital, Mkar were used for the calibration work. The radiation meter was used to measure x-ray radiation exposure. The result of this work demonstrates mR/mAs=C(KV p ) that there exist a power law relation of the form between the radiation exposure and the radiographic parameters of diagnostic x-ray machines, which can be used to estimate patient exposure during routine x-ray diagnostic examinations for wide range of operating parameters. The values of the power exponent n, constant c and total filtrations of the diagnostic x-ray machines have been estimated. These values for the diagnostic x-ray machines at the Federal Medical Centre, Makurdi are: 2.14, 0.88 and 2.77 respectively, for the one at the General Hospital, Otukpo are: 2.07, 0.76 and 2.68 respectively and that of the Christian Hospital, Mkar are: 2.01,0.69 and 2.61 respectively.

  19. A hard x-ray prototype production exposure station at NSLS

    International Nuclear Information System (INIS)

    Johnson, E.D.; Milne, J.C.

    1997-07-01

    Exposures conducted at the NSLS R and D beamline (X-27B) for High Aspect Ratio Precision Manufacture have proven sufficiently successful that the authors are constructing a dedicated hard x-ray exposure beamline. The new beamline (X-14B) provides an exposure field ∼ 120 mm wide, three times larger than that of X-27B. The scanner is based on the hydraulic system from the X-27B program. It is optimized for planar exposures and takes advantage of the full 525 mm stroke available. Exposures of multiple substrates and masks will be possible, with the fixturing supporting mounting of substrate holders from other groups (ALS, APS, CAMD, and UW). The function of this beamline is to establish a hard x-ray exposure station where manufacturing scale protocols can be developed and ultimately exploited for production runs

  20. Precise Surface Exposure Dating of Early Holocene and Little Ice Age Moraines in the Cordillera Vilcabamba of Southern Peru

    Science.gov (United States)

    Licciardi, J. M.; Schaefer, J. M.; Lund, D. C.; Taggart, J. R.

    2008-12-01

    We have established precise ages of two glacial events in the tropical Andean highlands of southern Peru. The field site is located on the flanks of Nevado Salcantay (6271 m asl; 13°20'S latitude), the highest peak in the Cordillera Vilcabamba. A two-fold sequence of nested lateral and end moraines was mapped in a glacial trough emanating from the south face of Salcantay. Well-defined outer and inner moraines were deposited by valley glaciers that terminated 5 km and 3 km, respectively, from their head on the Salcantay massif. Cosmogenic 10Be surface exposure dating of boulders on the outer (n = 7) and inner (n = 7) moraine crests expands upon initial age control for these deposits and improves substantially on the precision of earlier 10Be measurements. The new results yield mean ages of 9.0 ± 0.3 ka for the outer moraine and 195 ± 24 years for the inner moraine, corresponding to glacial events during the early and latest Holocene. These ages are derived using the CRONUS-Earth 10Be exposure age calculator with Lal-Stone production rate scaling and the default height-pressure relationship. The inner moraine age correlates with the timing of the Little Ice Age as defined from northern mid- and high latitude records, and indicates considerable expansion of glaciers heading on Nevado Salcantay during this climatic minimum. Recent geomorphic mapping has identified similar sequences of moraines in adjacent drainages on and near Salcantay, suggesting a broader regional signal of two prominent Holocene glacial events in this segment of the southern Peruvian Andes; 10Be dating of these additional moraines is underway. Our new glacier chronologies complement ice core and lacustrine paleoclimate records in the vicinity, thereby increasing spatial and temporal coverage for identifying patterns of climate change in the tropical Andes during the Holocene. Apart from their paleoclimatic significance, the results also demonstrate a newly- developed capability of 10Be exposure

  1. Pregnancy x-rays and childhood cancers: effects of exposure age and radiation dose

    International Nuclear Information System (INIS)

    Gilman, E.A.; Kneale, G.W.; Knox, E.G.; Stewart, A.M.

    1988-01-01

    Using data from the Oxford Survey of Childhood Cancers this paper examines the effect of foetal age and number of films used on the subsequent risk of childhood cancer associated with prenatal x-rays. X-rays early in pregnancy were taken for different reasons and required more films when compared with those taken in late pregnancy. Therefore, Mantel-Haenszel techniques were used to estimate the independent effects of (a) exposure age and (b) number of films. Age at exposure had a clearly significant effect; x-rays taken in the first trimester of pregnancy were 2.69 times as effective as x-rays taken in the third trimester. First trimester exposures were often the result of maternal illnesses, so these maternal illnesses were then included among the controlling factors. When this was done the first trimester x-rays were 2.73 times as effective as later exposures. First trimester x-rays were most strongly associated with the cancers which were diagnosed between 4 and 5 years of age. Although the number of films had no detectable effect upon relative risk calculated over all ages, multiple exposures were demonstrably associated with early age at diagnosis. (author)

  2. The problem of dating quartz 2: Synchrotron generated X-ray excited optical luminescence (XEOL) from quartz

    International Nuclear Information System (INIS)

    King, G.E.; Finch, A.A.; Robinson, R.A.J.; Taylor, R.P.; Mosselmans, J.F.W.

    2011-01-01

    The luminescence emission of quartz is used in optically stimulated luminescence dating (OSL), however the precise origins of the emission are unclear. A suite of quartz samples were analysed using X-ray excited optical luminescence (XEOL). Radiation dose effects were observed whereby the UV emissions (3.8 and 3.4 eV) were depleted to the benefit of the red emission (1.9-2.0 eV). Samples were excited at ∼7 keV. Understanding why some quartz emit light more brightly than others will increase the efficiency and precision of OSL analyses. - Highlights: → The X-ray excited optical luminescence (XEOL) emission of quartz is explored. → The XEOL of quartz of different provenances varies. → Radiation dosing causes UV emissions to deplete to the benefit of red emissions. → The 3.8 and 3.4 eV emissions deplete at the same rate. → The quartz luminescence emission exhibits anisotropic effects.

  3. Importance of Gender and Attitudes about Violence in the Relationship between Exposure to Interparental Violence and the Perpetration of Teen Dating Violence

    Science.gov (United States)

    Temple, Jeff R.; Shorey, Ryan C.; Tortolero, Susan R.; Wolfe, David A.; Stuart, Gregory L.

    2013-01-01

    Objective: Mounting evidence has demonstrated a link between exposure to family of origin violence and the perpetration of teen dating violence (TDV). However, only recently have mechanisms underlying this relationship been investigated and very few studies have differentiated between exposure to father-to-mother and mother-to-father violence.…

  4. AMS exposure dating : a case study from Himalaya and Tibet and its application potentials in earth science studies in India

    International Nuclear Information System (INIS)

    Sharma, K.K.

    1999-01-01

    The development of accelerator mass spectrometry (AMS) has made possible low level (10 -6 atoms/gm) measurements of 10 Be, 14 C, 26 Al, 36 Cl, 129 I isotopes in geological materials. Early studies investigated 10 Be atoms of cosmogenic nuclides produced mainly in the atmosphere (called garden variety), which subsequently admixed with the geological material from land surfaces get transported into the ocean waters and fixed in the ocean sediments. Subsequently, focus shifted to in-situ produced long-lived isotopes in quartz and their measurement in the terrestrial samples. This opened a new field of exposure dating and its potential applications in earth sciences and their role to study the time controlled processes resulting in diverse geomorphic landforms

  5. Timing of last deglaciation in the Cantabrian Mountains (Iberian Peninsula; North Atlantic Region) based on in situ-produced 10Be exposure dating

    Science.gov (United States)

    Rodríguez-Rodríguez, Laura; Jiménez-Sánchez, Montserrat; Domínguez-Cuesta, María José; Rinterknecht, Vincent; Pallàs, Raimon; Aumaître, Georges; Bourlès, Didier L.; Keddadouche, Karim; Aster Team

    2017-09-01

    The Last Glacial Termination led to major changes in ice sheet coverage that disrupted global patterns of atmosphere and ocean circulation. Paleoclimate records from Iberia suggest that westerly episodes played a key role in driving heterogeneous climate in the North Atlantic Region. We used 10Be Cosmic Ray Exposure (CRE) dating to explore the glacier response of small mountain glaciers (ca. 5 km2) that developed on the northern slope of the Cantabrian Mountains (Iberian Peninsula), an area directly under the influence of the Atlantic westerly winds. We analyzed twenty boulders from three moraines and one rock glacier arranged as a recessional sequence preserved between 1150 and 1540 m above sea level (a.s.l.) in the Monasterio valley (Redes Natural Park). Results complement previous chronologic data based on radiocarbon and optically stimulated luminescence from the Monasterio valley, which suggest a local Glacial Maximum (local GM) prior to 33 ka BP and a long-standing glacier advance at 24 ka coeval to the global Last Glacial Maximum (LGM). Resultant 10Be CRE ages suggest a progressive retreat and thinning of the Monasterio glacier over the time interval 18.1-16.7 ka. This response is coeval with the Heinrich Stadial 1, an extremely cold and dry climate episode initiated by a weakening of the Atlantic Meridional Overturning Circulation (AMOC). Glacier recession continued through the Bølling/Allerød period as indicate the minimum exposure ages obtained from a cirque moraine and a rock glacier nested within this moraine, which yielded ages of 14.0 and 13.0 ka, respectively. Together, they suggest that the Monasterio glacier experienced a gradual transition from glacier to rock glacier activity as the AMOC started to strengthen again. Glacial evidence ascribable to the Younger Dryas cooling was not dated in the Monasterio valley, but might have occurred at higher elevations than evidence dated in this work. The evolution of former glaciers documented in the

  6. X-ray detector for automatic exposure control using ionization chamber filled with xenon gas

    CERN Document Server

    Nakagawa, A; Yoshida, T

    2003-01-01

    This report refers to our newly developed X-ray detector for reliable automatic X-ray exposure control, which is to be widely used for X-ray diagnoses in various clinical fields. This new detector utilizes an ionization chamber filled with xenon gas, in contrast to conventional X-ray detectors which use ionization chambers filled with air. Use of xenon gas ensures higher sensitivity and thinner design of the detector. The xenon gas is completely sealed in the chamber, so that the influence of the changes in ambient environments is minimized. (author)

  7. Exposure measurement in the neighboring hospital beds during an x-ray procedure in hospitalization unit

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Rafael E.; Capeleti, Felipe F.; Cabete, Henrique V., E-mail: rafael.goto@fcmsantacasasp.edu.br, E-mail: felipe.capeleti@fcmsantacasasp.edu.br, E-mail: henrique@gmpbrasil.com.br [Faculdade de Ciencias Medicas da Santa Casa Sao Paulo, SP (Brazil); GMP Consultoria em Radioprotecao e Fisica Medica e Assessoria LTDA, Sao Paulo, SP (Brazil)

    2017-11-01

    There are lots of discussion about the exposure in hospitalization units in Brazil, especially around labor legislation and economic advantages of unhealthiness. With the attention focused on hospitalized patients, there were measured the exposure in neighboring beds of the patient submitted to an X-ray procedure with a mobile X-ray system that could be used to illustrate the discussion with consistent values. The most common X-ray procedure made in hospitalization units are chests images with techniques between 70 to 120 kV and 5 to 20 mAs. The measurement was made during routine exposure and simulations using a scattering phantom with Radcal AccuPro electrometer and 1800cc ionization chamber in a private hospital and a philanthropic hospital, both in Sao Paulo, Brazil. The ionization chambers are placed at 2 meters distance of the patient exposed of both sides during the routine procedure. During the simulation, a nylon phantom of 20 centimeters thick and 30 x 30 cm² size was placed on the bed, a typical exposure technique was used and the exposure was measured surrounding the phantom at 0.6, 1.0 and 2.0 meters distance for scattered radiation characterization. Initial results showed that the neighboring exposure at about 2 meters distance from the exposed patient bed have low values, even when exposure is integrated during the length of hospital stay. Therefore, the exposure in hospitalization units are very low compared to the exams doses. (author). (author)

  8. Energy and rate dependence of diagnostic x-ray exposure meters

    International Nuclear Information System (INIS)

    Wagner, L.K.; Cerra, F.; Conway, B.; Fewell, T.R.; Ohlhaber, T.R.

    1988-01-01

    Variations in x-ray exposure measurements among a variety of contemporary diagnostic exposure meters are investigated. Variations may result from systematic errors due to calibration, beam-quality dependence and exposure-rate dependence. It is concluded that the majority of general purpose diagnostic meters will agree to within 10% of each other if exposure rates are below 1.3 mC kg-1S-1 of air (5 R s-1) and beam qualities are typical for general purpose radiology, excluding mammography. For exposure rates comparable to those in barium enema radiography the variations can range up to 25% or more. Variations up to 40% were observed among general purpose exposure meters at mammographic beam qualities. In the mammographic range, mammographic (thin window) exposure meters varied by no more than 2%

  9. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2009-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

  10. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2008-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs

  11. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2012-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materials in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

  12. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2009-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs

  13. Luminescence dating

    International Nuclear Information System (INIS)

    Rieser, U.

    2013-01-01

    The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materials in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14 C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

  14. [Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation].

    Science.gov (United States)

    Olszewski, Jerzy; Wrzesień, Małgorzata

    2017-06-27

    The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes. Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films. The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs. The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491-496. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  15. Gender's Role in Exposure to Interparental Violence, Acceptance of Violence, Self-Efficacy, and Physical Teen Dating Violence Among Quebec Adolescents.

    Science.gov (United States)

    Ruel, Catherine; Lavoie, Francine; Hébert, Martine; Blais, Martin

    2017-05-01

    Despite efforts to prevent physical teen dating violence, it remains a major public health issue with multiple negative consequences. This study aims to investigate gender differences in the relationships between exposure to interparental violence (mother-to-father violence, father-to-mother violence), acceptance of dating violence (perpetrated by boys, perpetrated by girls), and self-efficacy to disclose teen dating violence. Data were drawn from Waves 1 and 2 of the Quebec Youth Romantic Relationships Project, conducted with a representative sample of Quebec high school students. Analyses were conducted on a subsample of 2,564 teenagers who had been in a dating relationship in the past 6 months (63.8% girls, mean age of 15.3 years). Path analyses were conducted to investigate the links among exposure to interparental violence, acceptance of violence, self-efficacy to disclose teen dating violence (measured at Wave 1), and physical teen dating violence (measured at Wave 2). General exposure to interparental violence was linked, through acceptance of girl-perpetrated violence, to victimization among both genders and to girls' perpetration of physical teen dating violence. No significant difference was identified in the impact of the gender of the perpetrating parent when considering exposure to interparental violence. Self-efficacy to disclose personal experiences of violence was not linked to exposure to interparental violence or to experiences of physical teen dating violence. The findings support the intergenerational transmission of violence. Moreover, the findings underline the importance of targeting acceptance of violence, especially girl-perpetrated violence, in prevention programs and of intervening with children and adolescents who have witnessed interparental violence.

  16. Observation of X-ray occupational exposure on psychological function of medical workers

    International Nuclear Information System (INIS)

    Gong Zhaolong; Li Xiuqin

    1988-01-01

    The present research is an attempt to study the psychological effects of long-term exposure to low-level X-ray on man. The subjects included 50 exposed people and 50 control. The battery of psychological tests consists of 10 subtests mainly involving memory and coordination ability. The results indicate that there are no statistical differences in all subtests between exposure and control group, but exposure group appears to be a little lower on most subtests about memory. With age, decline of psychological function is observed in all subtests in both groups. The subjects are further divided into three subgroups according to the number of X-ray exposed years. No statistical differences are found in all subgroups between exposure and control. Factor analysis has been made and two factors are obtained. factor 1 is mainly about speed of coordination, factor 2 is mainly about memory and attention. No statistical differences in factor scores are observed in all subgroups between exposure and control. Yet decline is found in factor 1 and factor 2 in both exposure and control groups with age. The results show that there is no significant effect of current dose level of X-ray exposure on human psychological function

  17. Determination of personnel exposures in the lower energy ranges of X-ray by photographic dosimeter

    International Nuclear Information System (INIS)

    Ha, C.W.; Kim, J.R.; Suk, K.W.

    1986-01-01

    This paper described an improved technical method required for proper evaluation of personnel exposures by means of the photographic dosimeter developed by KAERI in lower gamma or X-ray energy regions, with which response of the dosimeter varies significantly. With calibration of the dosimeter in the energy range from 30 to 300 keV, the beam spectrum was carefully selected and specified it adequately. The absorber combinations and absorber thickness used to obtain the specified X-ray spectra from a constant potential X-ray machine were determined theoretically and also experimentally. A correlation between the density and exposure for the four separate energies, such as 49 keV eff , 154 keV eff 250 keV eff and 662 keV, is experimentally determined. As a result, it can be directly evaluated the exposure from the measured response of dosimeter. (Author)

  18. Patient dose evaluations from medical X-ray exposure in Italy: an analysis of next data

    International Nuclear Information System (INIS)

    Marchetti, A.; Paganini, F.M.; Susanna, A.

    1980-01-01

    NEXT (Nationwide Evaluation of X-ray Trends) is a program for the evaluation of patient exposure in X-ray diagnostic tests. The program is aimed at reducing patient exposure by pin-pointing poor radiological techniques and improving them. CNEN (Comitato Nazionale per l'Energia Nucleare) and ISS (Istituto Superiore di Sanita) have been developing such a program in Italy since 1976. Up to now two regional administrations applied the method and regional operators collected the needed data in all the medical institutions in their areas. The results show a wide spread of values for all the parameters studied in the 12 X-ray projections selected. Gonad dose and skin entrance exposure were found to be spread over a range up to about two orders of magnitude. (H.K.)

  19. Phototimer for automatic control of x-ray exposure, PT-20A

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, H; Itoh, K; Ogura, I; Yasuhara, H; Sugimoto, H [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1979-02-01

    The phototimer as an exposure control device is now required to have higher accuracy and wider range of control to comply with the recent trends of x-ray diagnosis, such as toward short-time exposure due to increased output power of x-ray apparatus and toward one-man operation. In order to meet the requirement, the x-ray characteristics of the components of the phototimer have been examined, and computer simulation of x-ray spectra and dynamic characteristics of every component have been investigated, in pursuit of the essential characters of phototimers. On the basis of these analytical investigations, the phototimer PT-20A is so designed as to compensate for density deviation under various kVp and object thickness: uniform density has been obtained under practical radiographic conditions.

  20. High precision instrumentation for measuring the true exposure time in diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Silva, Danubia B.; Santos, Marcus A.P.; Barros, Fabio R.; Santos, Luiz A.P.

    2013-01-01

    One of the most important physical quantities to be evaluated in diagnostic radiology is the radiation exposure time experimented by the patient during the X-ray examination. IAEA and WHO organizations have suggested that any country must create a quality surveillance program to verify if each type of ionizing radiation equipment used in the hospitals and medical clinics are in conformity with the accepted uncertainties following the international standards. The purpose of this work is to present a new high precision methodology for measuring true exposure time in diagnostic X-ray examinations: pulsed, continuous or digital one. An electronic system named CronoX, which will be soon registered at the Brazilian Patent Office (INPI), is the equipment that provides such a high precision measurement. The principle of measurement is based on the electrical signal captured by a sensor that enters in a regeneration amplifier to transform it in a digital signal, which is treated by a microprocessor (uP). The signal treatment results in a two measured times: 1) T rx , the true X-ray exposure time; 2) T nx , the time in which the X-ray machine is repeatedly cut off during the pulsed irradiation and there is no delivery dose to the patient. Conventional Polymat X-ray equipment and dental X-ray machines were used to generate X-ray photons and take the measurements with the electronic systems. The results show that such a high precision instrumentation displays the true exposure time in diagnostic X-ray examinations and indicates a new method to be purposed for the quality surveillance programs in radiology. (author)

  1. Glacial and volcanic evolution on Nevado Coropuna (Tropical Andes) based on cosmogenic 36Cl surface exposure dating

    Science.gov (United States)

    Úbeda, J.; Palacios, D.; Vázquez-Selém, L.

    2012-04-01

    We have reconstructed the evolution of the paleo-glaciers of the volcanic complex Nevado Coropuna (15°S, 72°W; 6377 m asl) through the interpretation and dating of geomorphological evidences. Surface exposure dating (SED) based on the accumulation of 36Cl on the surface of moraine boulders, polished bedrock and lava flows allowed: 1) to confirm that the presence of ice masses in the region dates back to >80ka; 2) to produce chronologies of glacial and volcanic phases for the last ~21 ka; and 3) to obtain evidences of the reactivation of volcanic activity after the Last Glacial Maximum. Bromley et al. (2009) presented 3He SED ages of 21 ka for moraine boulders on the Mapa Mayo valley, to the North of Nevado Coropuna. Our 36Cl SED SED for moraine boulders from the valleys on the NE sector of the volcanic complex suggest a maximum initial advance between 20 and 16 ka, followed by another expansion of similar extent at 12-11 ka. On the Southern slope of Nevado Coropuna, the 36Cl ages show a maximum initial advance that reaches to the level of the Altiplano at 14 ka, and a re-advance at ~10-9 ka BP. Other data show minor re-advances at 9 ka on the Northern slope and at 6 ka to the South of the volcanic complex. These minor positive pulses interrupted a fast deglaciation process during the Holocene as shown by two series of 36Cl SED from polished rock surfaces on successively higher altitudes along the valleys of rivers Blanco and Cospanja, to the SW and SE. Despite the global warming occuring since 20 ka, deduced from the record of sea surface paleo-temperature of the Galapago Islands (Lea et al, 2006), the evolution of the fresh-water plankton from Lake Titicaca (Fritz et al, 2007) is consistent with sustained glacial conditions until 10-9 ka as suggested by the present work. Exposure ages of three lava flows indicate a reactivation of the magmatic system as the paleo-glaciers abandonned the slopes. The eruptive activity migrated from the West, where we found a lava

  2. The primary exposure standard of ENEA for medium energy X-ray: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a medium energy X-ray free-air chamber used, as primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the Enea in Italy. The main features of an X-ray facility for the production of radiation between 40 KeV and 400 KeV are also described. The measurements procedures are then analyzed with respect to the realization of the exposure unit in the relevant energy range. Finally the results of some international comparisons are reported

  3. Influence of chronic x-ray exposure on adrenal glucocorticoid function and adrenocorticocyte membrane potential

    International Nuclear Information System (INIS)

    Gorban', Je.M.; Topol'nikova, N.V.

    1998-01-01

    The peculiarities of adrenal glucocorticoid function and membrane potential (MP) of zona fasciculata adrenocorticocyte (ACC) in rats after chronic x-ray exposure was studied. The changes of adrenal glucocorticoid function caused by chronic x-ray exposure within a relatively small period of irradiation (1.5 months) are obscure and manifest themselves only at physiological load. With the prolongation of the period (8 and 15 months), more considerable inhibition of the adrenal glucocorticoid function and disturbances in the membrane mechanisms of ACC MP level regulation are revealed

  4. Radiation exposure in X-ray angiography and comparisons between digital and conventional methods of imaging

    International Nuclear Information System (INIS)

    Schaberg, J.

    1987-01-01

    The more recent developments and techniques in the field of angiography are examined for associated radiation exposure risks for patients and investigators and then compared to the conventional methods of angiography. It could be shown that digital subtraction angiography is generally associated with a lesser risk of somatic exposure of the patient, provided that the equipment used offers an adjustable useful-beam range and focus. The fact that above-table X-ray tubes are now generally replaced with X-ray systems installed under the examination table permits the relatively high doses, to which investigators are exposed during angiography, to be reduced by a factor of 3. (DG) [de

  5. An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

    International Nuclear Information System (INIS)

    Polee, C; Chankow, N; Srisatit, S; Thong-Aram, D

    2015-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking information of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a small detector. Application software was developed for Android mobile phone to remotely control the device and to display counting data via Bluetooth communication. Prior to film exposure, the device is placed behind a specimen to measure transmitted intensity which is inversely proportional to the exposure. Unlike in using the conventional exposure curve, correction factors for source decay, source-to- film distance, specimen thickness and kind of material are not needed. The developed technique and device make radiographic process economic, convenient and more reliable. (paper)

  6. Differences in responses to X-ray exposure between osteoclast and osteoblast cells

    International Nuclear Information System (INIS)

    Zhang, Jian; Wang, Ziyang; Wu, Anqing; Nie, Jing; Pei, Hailong; Hu, Wentao; Wang, Bing; Shang, Peng; Li, Bingyan; Zhou, Guangming

    2017-01-01

    Radiation-induced bone loss is a potential health concern for cancer patients undergoing radiotherapy. Enhanced bone resorption by osteoclasts and decreased bone formation by osteoblasts were thought to be the main reasons. In this study, we showed that both pre-differentiating and differentiating osteoclasts were relatively sensitive to X-rays compared with osteoblasts. X-rays decreased cell viability to a greater degree in RAW264.7 cells and in differentiating cells than than in osteoblastic MC3T3-E1 cells. X-rays at up to 8 Gy had little effects on osteoblast mineralization. In contrast, X-rays at 1 Gy induced enhanced osteoclastogenesis by enhanced cell fusion, but had no effects on bone resorption. A higher dose of X-rays at 8 Gy, however, had an inhibitory effect on bone resorption. In addition, actin ring formation was disrupted by 8 Gy of X-rays and reorganized into clusters. An increased activity of Caspase 3 was found after X-ray exposure. Actin disorganization and increased apoptosis may be the potential effects of X-rays at high doses, by inhibiting osteoclast differentiation. Taken together, our data indicate high radiosensitivity of osteoclasts. X-ray irradiation at relatively low doses can activate osteoclastogenesis, but not osteogenic differentiation. The radiosensitive osteoclasts are the potentially responsive cells for X-ray-induced bone loss.

  7. Comparison of cytogenetic effects after occupational exposure to X-rays with those after foetal pelvimetric exposure

    International Nuclear Information System (INIS)

    Kirsch-Volders, M.; Poma, K.; Verschaeve, L.; Hens, L.; Susanne, C.; Elegem, P. van

    1978-01-01

    In utero acute low-level exposure to X-rays (300 to 350 mrads) induces a significant increase of band-loss in G-trypsin banded chromosomes of umbilical lymphocytes. Results, however, have to be confirmed by dose-effect relation studies and analysis with spectro-photometric scanning of deleted chromosomes. The same in utero exposure induces a significant dissociaton of chromosome pair 13 as revealed by centromere-centromere, angle and association tendency analysis of chromosome distribution in comparison with a control group. Occupational chronic low-level exposure to ionizing radiation does not modify significantly the amount of SCE in lymphocytes of peripheral blood. However, an analysis of centromere-centromere distances, angle values and associaton tendencies of the different chromosome combinations clearly shows an association of chromosome pair 12-16 after exposure to ionizing radiation. It is difficult to assess the exact biological importance of the observed chromosome modifications. However, referring to the already described dissociation of human acrocentric chromosomes after in vivo exposure to low levels of phenyl Hg acetate or inorganic Pb, the chromosome distribution seems not to be significantly disturbed by chronic or acute low-level exposure to ionizing radiation. (author)

  8. Radiation exposure and image quality in x-Ray diagnostic radiology physical principles and clinical applications

    CERN Document Server

    Aichinger, Horst; Joite-Barfuß, Sigrid; Säbel, Manfred

    2012-01-01

    The largest contribution to radiation exposure to the population as a whole arises from diagnostic X-rays. Protecting the patient from radiation is a major aim of modern health policy, and an understanding of the relationship between radiation dose and image quality is of pivotal importance in optimising medical diagnostic radiology. In this volume the data provided for exploring these concerns are partly based on X-ray spectra, measured on diagnostic X-ray tube assemblies, and are supplemented by the results of measurements on phantoms and simulation calculations.

  9. Exposure doses of the patient and the medical staff during urological X-ray examens

    International Nuclear Information System (INIS)

    Vogel, H.; Loehr, H.; Haug, P.; Schuett, B.

    1977-01-01

    During 32 intravenous urografies and 48 angiografies of the kidney and the suprarenal glands the X-ray doses at the patient's skin and gonades were determined. During the angiografies the doses were mesured at the hands. the gonades and the front (eyes) of the medical staff. The results are discussed. Because the X-ray doses are relatively high, the number of the pictures and the exposure time is to be reduced to the minimum. Clinical experience and special knowledge is the best X-ray protection. (orig.) [de

  10. Color change of gemstones by exposure to gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Giovanna L.C. de; Lameiras, Fernando S., E-mail: giovannalarissa17@hotmail.com, E-mail: fsl@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    A gem is appreciated by collectors and, when polished, widely used for jewelry manufacturing. For example, when quartz naturally or artificially acquires a color it becomes a gemstone (smoky quartz, morion, citrine, amethyst, or prasyolite). The presence of chromophore elements in a quartz sample was analysed by Fourier transform infrared spectrometry (FTIR). With a semi-quantitative analysis of the absorption FTIR spectra, it was possible to predict if colorless quartz has the potential to develop color when exposed to ionizing radiation and heat. Specific absorption bands show the presence of chromophore elements in quartz such as aluminum, iron, hydrogen, sodium, or lithium. Considering the ratio of the heights of the absorption bands of these elements, it was possible to predict the color quartz can develop. Samples of irradiated dark and light violet fluorites were analyzed by FTIR and energy-dispersive X-rays spectroscopy. The light violet samples has higher content of calcium relative to fluorine, as well higher content of hydroxyl, probably replacing fluorine in crystal lattice. Hydroxyls cannot be precursors of F color centers, which are the cause of violet color in fluorite, explaining the light violet color of hydroxyl-rich samples. (author)

  11. Color change of gemstones by exposure to gamma rays

    International Nuclear Information System (INIS)

    Lima, Giovanna L.C. de; Lameiras, Fernando S.

    2015-01-01

    A gem is appreciated by collectors and, when polished, widely used for jewelry manufacturing. For example, when quartz naturally or artificially acquires a color it becomes a gemstone (smoky quartz, morion, citrine, amethyst, or prasyolite). The presence of chromophore elements in a quartz sample was analysed by Fourier transform infrared spectrometry (FTIR). With a semi-quantitative analysis of the absorption FTIR spectra, it was possible to predict if colorless quartz has the potential to develop color when exposed to ionizing radiation and heat. Specific absorption bands show the presence of chromophore elements in quartz such as aluminum, iron, hydrogen, sodium, or lithium. Considering the ratio of the heights of the absorption bands of these elements, it was possible to predict the color quartz can develop. Samples of irradiated dark and light violet fluorites were analyzed by FTIR and energy-dispersive X-rays spectroscopy. The light violet samples has higher content of calcium relative to fluorine, as well higher content of hydroxyl, probably replacing fluorine in crystal lattice. Hydroxyls cannot be precursors of F color centers, which are the cause of violet color in fluorite, explaining the light violet color of hydroxyl-rich samples. (author)

  12. Modelling of Earthquake History of the Knidos Fault Zone SW Turkey Using in-situ 36Cl Surface Exposure Dating by R

    Science.gov (United States)

    Sahin, S.; Yıldırım, C.; Sarıkaya, M. A.; Tuysuz, O.; Genç, S. C.; Aksoy, M. E.; Doksanaltı, M. E.; Benedetti, L.

    2016-12-01

    Cosmogenic surface exposure dating is based on the production of rare nuclides in exposed rocks, which interact with cosmic rays. Through modelling of measured 36Cl concentrations, we might obtain information of the history of the earthquake activity. Yet, there are several factors which may impact production of rare nuclides such as geometry of fault, topography, geographic location of study area, temporal variations of the Earth's magnetic field, self-cover and denudation rate on the scarp. Our study area, the Knidos Fault Zone, is located on the Datça Peninsula in the Southwestern Anatolia and contains several normal fault scarps formed within the limestone, which are appropriate to apply cosmogenic chlorine-36 dating. Since it has a well-preserved scarp, we have focused on the Mezarlık Segment of the fault zone, which has an average length of 300 m and height 12-15 m. 128 continuous samples from top to bottom of the fault scarp were collected to carry out analysis of cosmic 36Cl isotopes concentrations. Recent research elucidated each step of the application of this method by the Matlab (e.g. Schlagenhauf et al., 2010). It is vitally helpful to generate models activity of normal faults. We, however, wanted to build a user-friendly program through an open source programing language R that might be able to help those without knowledge of complex math, programming, making calculations as easy as possible. We have set out to obtain accurate conclusions to compare and contrast our results with synthetic profiles and previous studies of limestone fault scarps. The preliminary results indicate at least three major or more earthquakes/earthquakes cluster events occurred on the Mezarlık fault within the past 20 kyr; over 10 meters of displacement took place between early Holocene and late Pleistocene. Estimated ages of those three large slip events are 18.7, 15.1 and 10.8 ka respectively. This study was conducted with the Decision of the Council of Ministers with No

  13. Hygiene implications associated with x-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients, then a skeleton encased in plastic, was instrumented with LiF thermoluminescent dosimeters to quantify radiation exposures delivered from full-face diagnostic dental x-rays. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices

  14. Occupational exposure of medical staff due to diagnostic X-ray examinations in veterinary medicine

    International Nuclear Information System (INIS)

    Mergel, E.; Feige, S.; Haeusler, U.

    2007-01-01

    The implementation of the Council directive 96/29 EURATOM and the corresponding national Radiation Protection Ordinance and the X-ray Protection Ordinance coming subsequently into effect led to a changed situation regarding the occupational radiation protection in the medical sector. To reduce the occupational exposure of veterinarians and assisting staff in veterinary radiography is particularly challenging as, in opposite to human radiological examination, the presence of staff is indispensable to restrain the patient. Beyond that the relevant literature reports about too high and/or about unnecessary radiation exposures. To gain a comprehensive knowledge upon the possible exposure of involved staff, the variety of typical examination methods in veterinary clinics and at practitioners had been investigated during the daily routine. Dose measurements were performed for different employees during the examinations taking into account several places of exposure (lens, thyroid, chest, hand, gonad, and feet). Veterinary X-ray diagnostic examinations for pets as well as in equine radiography had been accounted for this study. In total, 101 examination methods, 4.484 accompanied examinations and 53.892 single dose readings resulted in a reliable statistical base to set up a 'Job-Exposure-Matrix' allowing the dose assessment for a variable number and kind of examinations. The 'Job-Exposure-Matrix' is believed to be a useful tool for optimization of occupational radiation exposure of veterinarians by appraising the height of a possible dose, forcing a review of the status quo and triggering the improvement of personal protection by establishing adequate measures. (orig.)

  15. Annama H chondrite-Mineralogy, physical properties, cosmic ray exposure, and parent body history

    Czech Academy of Sciences Publication Activity Database

    Kohout, Tomáš; Haloda, J.; Halodová, P.; Meiner, M. M. M.; Maden, C.; Busemann, H.; Laubenstein, M.; Caffee, M. W.; Welten, K.C.; Hopp, J.; Trieloff, M.; Mahajan, R. R.; Naik, S.; Trigo-Rodríguez, J.M.; Moyano-Cambero, C. E.; Oshtrakh, M. I.; Maksimova, A. A.; Chukin, A. V.; Semionkin, V. A.; Karabanalov, M. S.; Felner, I.; Petrova, E. V.; Brusnitsyna, E. V.; Grokhovsky, V. I.; Yakovlev, G. A.; Gritsevich, M.; Lyytinen, E.; Moilanen, J.; Kruglikov, N. A.; Ishchenko, A. V.

    2017-01-01

    Roč. 52, č. 8 (2017), s. 1525-1541 ISSN 1086-9379 Institutional support: RVO:67985831 Keywords : Annama * chondrite * cosmic-ray exposure * radionuclide Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 2.391, year: 2016

  16. Cost Benefit Optimization of the Israeli Medical Diagnostic X-Ray Exposure

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Shlesinger, T.; Shani, G.; Kushilevsky, A.

    1999-01-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. A preliminary survey was carried out during 1997 on 3 major Israeli hospitals in order to assess the extent of exposure of the population to medical x-rays (1). The survey has found that the annual collective dose of the Israeli population to x-ray medical imaging procedures (excluding radio-therapy) is about 7,500 Man-Sv. The results of the survey were analyzed in order to. 1. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of the Israeli patients under x-ray procedures. 2. Establish a set of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. . Establish a number of basic rules to be utilized by health policy makers in Israel. Based on the ICRP-60 linear model risk assessments (2), the extent of the annual risk arising A.om the 7,500 Man-Sv medical x-ray collective dose in Israel has been found to be the potential addition of 567 cancer cases per year, 244 of which to be fatal, and a potential additional birth of 3-4 children with severe genetic damage per year. This assessment take into account the differential risk and the collective dose according to the age distribution in the Israeli exposed population, and excludes patients with chronic diseases

  17. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  18. Dental X-ray diagnostic facility with means to choose the time of exposure

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H; Grassme, U

    1978-02-16

    Equipment for dental X-ray diagnostics with automatic exposure control. In the patient's mouth there is arranged a film carrier containing in a pocket a dental X-ray film. A detector-transmitter assembly touches the pocket. It reacts to the density of the film and wireless transmits a signal to an antenna. This antenna is connected to a receiver shutting off the high voltage of the X-ray tube by means of a circuit if a desired dose value is reached. The detector-transmitter unit is an integrated component. It has got a luminescent layer with a light-sensitive detector or a detector directly sensitive to X-rays.

  19. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.

    Science.gov (United States)

    Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael

    2017-09-01

    Purpose  Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods  Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results  The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm 2 (flat panel detector systems: 155 cGy*cm 2 ; X-ray image intensifier: 175 cGy*cm 2 ). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm 2 ), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT - flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion  In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe

  20. Exposure to family violence and attachment styles as predictors of dating violence perpetration among men and women: a mediational model.

    Science.gov (United States)

    Lee, Mary; Reese-Weber, Marla; Kahn, Jeffrey H

    2014-01-01

    This study examined a multiple mediator model explaining how sibling perpetration and one's attachment style mediate the relation between parent-to-child victimization and dating violence perpetration. A sample of undergraduate students (n = 392 women, n = 89 men) completed measures of the aforementioned variables on an Internet survey. For men, path analyses found no mediation; parent-to-child victimization had a direct association with dating violence perpetration, no association was found between sibling perpetration and dating violence perpetration, and attachment anxiety, but not attachment avoidance, was positively associated with dating violence perpetration for men. For women, the hypothesized mediation model was supported; parent-to-child victimization had a direct association with dating violence perpetration, and sibling perpetration and attachment anxiety served as mediating variables. Attachment avoidance was not associated with dating violence perpetration for women. Implications for future research and clinical practice are discussed.

  1. Combined exposure of ELF magnetic fields and X-rays increased mutant yields compared with X-rays alone in pTN89 plasmids

    International Nuclear Information System (INIS)

    Koyama, Shin; Nakahara, Takehisa; Sakurai, Tomonori; Komatsubara, Yoshiki; Miyakoshi, Junji; Isozumi, Yasuhito

    2005-01-01

    We have examined mutations in the supF gene carried by pTN89 plasmids in Escherichia coli (E. coli) to examine the effects of extremely low frequency magnetic fields (ELFMFs) and/or X-rays to the plasmids. The plasmids were subjected to sham exposure or exposed to an ELFMF (5 mT), with or without X-ray irradiation (10 Gy). For the combined treatments, exposure to the ELFMF was immediately before or after X-ray irradiation. The mutant fractions were 0.94 x 10 -5 for X-rays alone, 1.58 x 10 -5 for an ELFMF followed by X-rays, and 3.64 x 10 -5 for X-rays followed by an ELFMF. Increased mutant fraction was not detected following exposure to a magnetic field alone, or after sham exposure. The mutant fraction for X-rays followed by an ELFMF was significantly higher than those of other treatments. Sequence analysis of the supF mutant plasmids revealed that base substitutions were dominant on exposure to X-rays alone and X-rays plus an ELFMF. Several types of deletions were detected in only the combined treatments, but not with X-rays alone. We could not find any mutant colonies in sham irradiated and an ELFMF alone treatment, but exposure to ELFMFs immediately before or after X-ray irradiation may enhance the mutations. Our results indicate that an ELFMF increases mutation and alters the spectrum of mutations. (author)

  2. Deformation and stress in PMMA during hard X-ray exposure for deep lithography

    International Nuclear Information System (INIS)

    Moldovan, N.

    1999-01-01

    The availability of high-energy, high-flux, collimated synchrotrons radiation has extended the application of deep X-ray lithography (DXRL) to thickness values of the PMMA resist of several millimeters. Some of the most severe limitations come from plastic deformation, stress, and cracks induced in PMMA during exposure and development. We have observed and characterized these phenomena quantitatively. Profilometry measurements revealed that the PMMA is subjected either to local shrinkage or to expansion, while compression and expansion evolve over time. Due to material loss and crosslinking, the material undergoes a shrinkage, while the radiation-induced decomposition generates gases expanding the polymer matrix. The overall dynamics of the material microrelief and stress during and after the exposure depend on the balance between compaction and outgassing. These depend in turn on the exposure conditions (spectrum; dose, dose rate, seaming, temperature), post-exposure storage conditions, PMMA material properties and thickness, and also on the size and geometry of the exposed patterns

  3. Calculation on cosmic-ray muon exposure rate in non-walled concrete buildings

    International Nuclear Information System (INIS)

    Fujitaka, Kazunobu; Abe, Siro

    1984-01-01

    Computer simulations on the exposure indoors from cosmic ray muons were practiced in the framework of non-scattering and non-cascade assumptions. The model buildings were two-dimensional, rectangular, and were made of a normal concrete. A stratified structure was assumed in each building, where no mezzanine was considered. Walls were not taken into account yet. The distributions of the exposure rates in 26-story buildings were illustrated in contour maps for various sets of parameters. All of them gave basically archlike patterns. Analyses of the results showed that the exposure rate is affected most largely by the floor board thickness. The ceiling height would be an insignificant factor for short buildings. The min/max ratio of the muon exposure rate in a moderate size building was estimated to be more than 0.7. (author)

  4. Micronucleus induction by repeated exposure of diagnostic X-ray on oral buccal mucosa

    International Nuclear Information System (INIS)

    Lohith Tejashvi, K.; Suchetha Kumari, N.; Shetty, Shishir Ram

    2012-01-01

    Radiography is the important diagnostic tools essential for diagnosis and planning of orthodontic treatment. X-ray is ionizing radiation which showed various effects include breaking the bond of biological molecules, inducing loss of ability of cell death, increases nuclear alterations. Micronuclei - x000D - (MN) are small chromatin bodies that appear in the cytoplasm by the - x000D - condensation of acrocentric chromosomal fragments or by whole chromosomes. This - x000D - is a sensitive indicator of genetic damage. - x000D - x000D - . To evaluate micronucleus induction by repeated exposure of diagnostic X-ray on human buccal cell. Methods: 25 patients who visiting to ABSMIDS, Department of Oral medicine and Radiology for dental checkup exposed to diagnostic X-ray more than 4 times have been selected for this study. The buccal cell for analysis was collected from the cheek mucosa by means of gentle scraping of epithelial using ice-cream sticks and placed in Buffer saline. This sample was smeared on glass slide and then fixed in methanol:glacial acetic acid (3:1). Air dried and stained with Giemsa for 15-25 minutes. Then 250 cells in each slides were analyzed under microscope and frequency of micronucleus was scored (n=4). Repeated X-ray exposed cells showed micronucleus (1.25%) and nuclear alteration (2.3%) compare to the control. Repeated X-ray exposure leads to induces detectable number of micronucleus and nuclear alterations. (author)

  5. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    International Nuclear Information System (INIS)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S

    2006-01-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process

  6. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 373-1, Guseong-dong, Yuseong-dong, Daejeon (Korea, Republic of)

    2006-04-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process.

  7. X-ray exposure in utero and school performance: a population-based study of X-ray pelvimetry

    International Nuclear Information System (INIS)

    Nordenskjöld, A.C.; Palme, M.; Kaijser, M.

    2015-01-01

    Aim: To investigate the association between exposure to ionising radiation from pelvimetric examinations in utero and school performance. Material and methods: This was a population-based cohort study comprising 46,066 children born in the county of Östergötland, Sweden, from 1980 through 1990. Through record linkage between Swedish registers, children exposed in utero to X-ray pelvimetry examination were compared to other children born in the same county during the study period, as well as to their unexposed siblings. Outcome variable was primary school grades, expressed in centiles and calculated through linear regression. Results: In the univariate analysis, children exposed to X-ray pelvimetry in utero had higher school grades compared to unexposed children (point estimate 3 centiles, 95% confidence interval [CI]: 1.5 to 4.6). When sex, mother's education and income, birth order, and birth position were included in the analysis; however, the difference was reduced and the association was no longer statistically significant (PE 1.4, 95% CI: –0.1 to 2.8). Comparing exposed children with their siblings showed no statistical difference in univariate analysis or in multivariate analysis. Conclusion: No suggestion was found of a negative effect on school performance from in utero exposure of diagnostic X-ray pelvimetry. -- Highlights: •Pelvimetric examinations expose fetus to low levels of radiation. •No detectable effect on childrens final primary school grades from pelvimetric examinations. •Pelvimetric examinations is a safe procedure for the fetus regarding shool performance

  8. Exposure reduction in general dental practice using digital x-ray imaging system for intraoral radiography with additional x-ray beam filter

    International Nuclear Information System (INIS)

    Shibuya, Hitoshi; Mori, Toshimichi; Hayakawa, Yoshihiko; Kuroyanagi, Kinya; Ota, Yoshiko

    1997-01-01

    To measure exposure reduction in general dental practice using digital x-ray imaging systems for intraoral radiography with additional x-ray beam filter. Two digital x-ray imaging systems, Pana Digital (Pana-Heraus Dental) and CDR (Schick Technologies), were applied for intraoral radiography in general dental practice. Due to the high sensitivity to x-rays, additional x-ray beam filters for output reduction were used for examination. An Orex W II (Osada Electric Industry) x-ray generator was operated at 60 kVp, 7 mA. X-ray output (air-kerma; Gy) necessary for obtaining clinically acceptable images was measured at 0 to 20 cm in 5 cm steps from the cone tip using an ionizing chamber type 660 (Nuclear Associates) and compared with those for Ektaspeed Plus film (Eastman Kodak). The Pana Digital system was used with the optional filter supplied by Pana-Heraus Dental which reduced the output to 38%. The exposure necessary to obtain clinically acceptable images was only 40% of that for the film. The CDR system was used with the Dental X-ray Beam Filter Kit (Eastman Kodak) which reduced the x-ray output to 30%. The exposure necessary to obtain clinically acceptable images was only 20% of that for the film. The two digital x-ray imaging systems, Pana Digital and CDR, provided large dose savings (60-80%) compared with Ektaspeed Plus film when applied for intraoral radiography in general dental practice. (author)

  9. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Czech Academy of Sciences Publication Activity Database

    Bártová, H.; Kučera, Jan; Musílek, L.; Trojek, T.

    2014-01-01

    Roč. 104, NOV (2014), s. 393-397 ISSN 0969-806X. [1st International Conference on Dosimetry and its Applications (ICDA). Prague, 23.6.2013-28.6.2013] R&D Projects: GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : Alpha coutning * neutron activation analysis * X-ray fluorescence * thermoluminescence dating * dose rate Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.380, year: 2014

  10. Noble gases, nitrogen and cosmic ray exposure age of the Sulagiri chondrite

    Directory of Open Access Journals (Sweden)

    Ramakant R. Mahajan

    2017-01-01

    Full Text Available The Sulagiri meteorite fell in India on 12 September 2008, LL6 chondrite class is the largest among all the Indian meteorites. Isotopic compositions of noble gases (He, Ne, Ar, Kr and Xe and nitrogen in the Sulagiri meteorite and cosmic ray exposure history are discussed. Low cosmogenic (22Ne/21Nec ratio is consistent with irradiation in a large body. Cosmogenic noble gases indicate that Sulagiri has a 4π cosmic-ray exposure (CRE age of 27.9 ± 3.4 Ma and is a member of the peak of CRE age distribution of LL chondrites. Radiogenic 4He and 40Ar concentrations in Sulagiri yields the radiogenic ages as 2.29 and 4.56 Ga, indicating the loss of He from the meteorite. Xenon and krypton are mixture of Q and spallogenic components.

  11. Noble gases, nitrogen and cosmic ray exposure age of the Sulagiri chondrite

    Institute of Scientific and Technical Information of China (English)

    Ramakant R. Mahajan

    2017-01-01

    The Sulagiri meteorite fell in India on 12 September 2008, LL6 chondrite class is the largest among all the Indian meteorites. Isotopic compositions of noble gases (He, Ne, Ar, Kr and Xe) and nitrogen in the Sulagiri meteorite and cosmic ray exposure history are discussed. Low cosmogenic (22Ne/21Ne)c ratio is consistent with irradiation in a large body. Cosmogenic noble gases indicate that Sulagiri has a 4πcosmic-ray exposure (CRE) age of 27.9 ± 3.4 Ma and is a member of the peak of CRE age distribution of LL chondrites. Radiogenic 4He and 40Ar concentrations in Sulagiri yields the radiogenic ages as 2.29 and 4.56 Ga, indicating the loss of He from the meteorite. Xenon and krypton are mixture of Q and spallo-genic components.

  12. An Industrial Radipgraphy Exposure Device Based on Measurement of Transmitted Gamma-Ray Intensity

    International Nuclear Information System (INIS)

    Polee, C.; Chankow, N.; Srisatit, S.; Thong-Aram, D.

    2014-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking knowledge of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a D3372 Hamamatsu small GM tube. Application software is developed for Android mobile phone to remotely control the device and to display the counting data via Bluetooth. Prior to placing film, the device is placed behind the specimen to be radiographed to determine the exposure time from the transmitted intensity which is independent on source activity, source-to-film distance, specimen thickness and kind of material. The developed technique and device make radiographic process economic, convenient and more reliable.

  13. Occupational exposure of medical staff due to diagnostic X-ray examinations in veterinary medicine

    Energy Technology Data Exchange (ETDEWEB)

    Mergel, E.; Feige, S. [Gesellschaft fuer Anlagen- und Reaktorsicherheit mbH (GRS) (Germany); Haeusler, U. [Bundesamt fuer Strahlenschutz (BfS), Salzgitter (Germany)

    2007-07-01

    The implementation of the Council directive 96/29 EURATOM and the corresponding national Radiation Protection Ordinance and the X-ray Protection Ordinance coming subsequently into effect led to a changed situation regarding the occupational radiation protection in the medical sector. To reduce the occupational exposure of veterinarians and assisting staff in veterinary radiography is particularly challenging as, in opposite to human radiological examination, the presence of staff is indispensable to restrain the patient. Beyond that the relevant literature reports about too high and/or about unnecessary radiation exposures. To gain a comprehensive knowledge upon the possible exposure of involved staff, the variety of typical examination methods in veterinary clinics and at practitioners had been investigated during the daily routine. Dose measurements were performed for different employees during the examinations taking into account several places of exposure (lens, thyroid, chest, hand, gonad, and feet). Veterinary X-ray diagnostic examinations for pets as well as in equine radiography had been accounted for this study. In total, 101 examination methods, 4.484 accompanied examinations and 53.892 single dose readings resulted in a reliable statistical base to set up a 'Job-Exposure-Matrix' allowing the dose assessment for a variable number and kind of examinations. The 'Job-Exposure-Matrix' is believed to be a useful tool for optimization of occupational radiation exposure of veterinarians by appraising the height of a possible dose, forcing a review of the status quo and triggering the improvement of personal protection by establishing adequate measures. (orig.)

  14. Stony meteoroid space erosion and drag: Effect on cosmic ray exposure ages

    Science.gov (United States)

    Rubincam, David Parry

    2017-09-01

    Collisions with dust particles in retrograde orbits cause space erosion on stony meteoroids in addition to the particle drag which causes drift toward resonances. The spacing between resonances determines the maximum drift time and sets upper limits on the neon-21 cosmic ray exposure (CRE) ages for meteoroids less than ∼1 m in radius, while space erosion controls the limit for radii greater than ∼1 m; the limits accord well with the measured CRE ages of stony meteorites.

  15. Cytological evidence of chromosomal rearrangement in the second meiotic division after exposure to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Szemere, G. (Orvostudomanyi Egyetem, Szeged (Hungary). Orvosbiologiai Intezet)

    1982-01-01

    Metaphase II cells with unequal dyad-arms and obvious X/autosomal rearrangements were found after an exposure to X-rays (2 Gy) of male mice at different stages of meiosis (pachytene, diplotene and diakinesis) with a frequency of 0.2, 1.26 and 0.6%, respectively, giving a direct cytological evidence of structural chromosomal rearrangements in metaphase II cells, partly with autosomal and partly with X/autosomal partners.

  16. Cytological evidence of chromosomal rearrangement in the second meiotic division after exposure to X-rays

    International Nuclear Information System (INIS)

    Szemere, G.

    1982-01-01

    Metaphase II cells with unequal dyad-arms and obvious X/autosomal rearrangements were found after an exposure to X-rays (2 Gy) of male mice at different stages of meiosis (pachytene, diplotene and diakinesis) with a frequency of 0.2, 1.26 and 0.6%, respectively, giving a direct cytological evidence of structural chromosomal rearrangements in metaphase II cells, partly with autosomal and partly with X/autosomal partners. (author)

  17. Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

    Science.gov (United States)

    Benyo, Theresa L.; Steinetz, Bruce M.; Hendricks, Robert C.; Martin, Richard E.; Forsley, Lawrence P.; Daniels, Christopher C.; Chait, Arnon; Pines, Vladimir; Pines, Marianna; Penney, Nicholas; hide

    2017-01-01

    Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 µA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4s confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

  18. Hospital and clinic survey estimates of medical x-ray exposures in Hiroshima and Nagasaki, (1)

    International Nuclear Information System (INIS)

    Sawada, Shozo; Land, C.E.; Otake, Masanori; Russell, W.J.; Takeshita, Kenji.

    1980-11-01

    All large hospitals and 40% of the small hospitals and clinics in Hiroshima and Nagasaki cities were surveyed for the X-ray examinations they performed during a 2-week period in 1974. The frequency and type of X-ray examinations received by members of the RERF Adult Health Study (AHS) and the RERF Life Span Study (LSS) extended, excluding AHS (Non-AHS), were compared with the general population in each city. Radiologic exposures of patients at hospitals and clinics were most frequent among the general populations. The number of patients, examinations, and exposures per caput per year in each population were estimated. Since the age distribution differed among the three populations, comparisons were made only after correcting for age. On a per caput per year basis exposure frequency was relatively high in the AHS and low in the general populations, a reflection of the greater number of patients in the AHS than in the general populations. Non-AHS males in Nagasaki had a higher X-ray examination rate than did the AHS subjects. The others in the Non-AHS did not differ appreciably from the general populations. There was no difference among these groups according to body sites examined. (author)

  19. Digital image acquisition in the X-ray diagnostics. Its influence on the patients' exposure

    International Nuclear Information System (INIS)

    Hoberg, Bernd; Voigt, Stefan

    2012-01-01

    Radiation exposure in the classical X-ray diagnostics was continuously reduced during the past years. The annual report 2009 of the Bundesamt fuer Strahlenschutz (BfS) shows that 46% of the radiological examinations in Germany concern the skeleton, the lungs and the digestive and urogenital tract. The respective radiation dose is only 20% of the total dose of the public from X-ray diagnostic measures. Considering computerized tomography, angiography and interventional radiology, that amount to about 10% of the radiological examinations, their dose percentage reaches about 80%. Therefore, the emphasis of modern radiation protection has to be targeted to digital techniques in the future X-ray diagnostics. The authors describe digital detectors, direct and indirect digitalized image receivers, flat-panel detectors and dynamic detectors.

  20. Update of diagnostic medical and dental x-ray exposures in Romania

    Energy Technology Data Exchange (ETDEWEB)

    Sorop, Ioana; Mossang, Daniela; Dadulescu, Elena [Radiation Hygiene Laboratory of Public Health Authority Dolj, 2, Constantin Lecca Street, Craiova (Romania); Iacob, Mihai Radu [University ' Alexandru Ioan Cuza' , 11, Carol I Street, 700506, Iasi (Romania); Iacob, Olga [Institute of Public Health, 14, Victor Babes Street, 700465 Iasi (Romania)], E-mail: danamossang@sanpubdj.ro

    2008-12-15

    This national study, the third in the last 15 years, updates the magnitude of medical radiation exposure from conventional x-ray examinations, in order to optimise the radiological protection to the population in a cost-effective manner. Effective doses from diagnostic radiology were estimated for adult and paediatric patients undergoing the 20 most important types of x-ray examination. Data were collected from 179 x-ray departments, selected by their annual workload, throughout the country. Estimates were made using two dosimetric quantities: entrance surface dose, derived from the absorbed dose in air measured by simulation of radiographic examinations, and dose-area product, measured during fluoroscopic examinations performed on adult and paediatric patients. Conversion coefficients to effective dose of the UK National Radiological Protection Board (NRPB) have been used in all calculations. The effective dose per patient from all medical x-ray examinations was 0.74 mSv and the resulting annual collective effective dose was 6930 man Sv, with annual effective dose per caput of 0.33 mSv. The current size of population exposure from diagnostic radiology is lower than the previous one by 40%, but could be about 30% higher by taking into account the estimated contribution from computed tomography (CT) procedures.

  1. Radiation exposure to chest X-rays in the neonatal nursery

    International Nuclear Information System (INIS)

    Takeuchi, Toshio; Itabashi, Kazuo; Kawaguchi, Shigeru; Suzuka, Takahisa; Okuyama, Kazuo

    1989-01-01

    To measure how much very low birth-weight infants are exposed to chest X-rays during nursery, skin doses were calculated using phantoms under the same condition as that used in chest X-rays. Skin doses obtained were multiplied by the number of X-rays performed in 86 very low birth-weight infants (mean birth weight+-SD, 1163.0+-232.8 g; mean gestational age+-SD, 29.3+-3.0 week). Exposure doses per film ranged from 4.9 to 14.4 mR, with a mean dose of 6.1+-2.0 mR. Exposure doses per neonate ranged from 6.3 to 794.3 mR, with a mean dose of 170.4+-151.5 mR. The number of films per neonate ranged from one to 107, with a mean of 28.0+-24.9. Eighty-seven percent of X-rays were performed when the body weight was 1,500 g or less. Fourteen patients received 300 mR or more that may be the potential dose of radiation effects. (Namekawa, K)

  2. Optimization of exposure factors for X-ray radiography non-destructive testing of pearl oyster

    Science.gov (United States)

    Susilo; Yulianti, I.; Addawiyah, A.; Setiawan, R.

    2018-03-01

    One of the processes in pearl oyster cultivation is detecting the pearl nucleus to gain information whether the pearl nucleus is still attached in the shell or vomited. The common tool used to detect pearl nucleus is an X-ray machine. However, an X-ray machine has a drawback that is the energy used is higher than that used by digital radiography. The high energy make the resulted image is difficult to be analysed. One of the advantages of digital radiography is the energy used can be adjusted so that the resulted image can be analysed easily. To obtain a high quality of pearl image using digital radiography, the exposure factors should be optimized. In this work, optimization was done by varying the voltage, current, and exposure time. Then, the radiography images were analysed using Contrast to Noise Ratio (CNR). From the analysis, it can be determined that the optimum exposure factors are 60 kV of voltage, 16 mA of current, and 0.125 s of exposure time which result in CNR of 5.71.

  3. A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems

    International Nuclear Information System (INIS)

    Yadava, G K; Kuhls-Gilcrist, A T; Rudin, S; Patel, V K; Hoffmann, K R; Bednarek, D R

    2008-01-01

    The performance of high-sensitivity x-ray imagers may be limited by additive instrumentation noise rather than by quantum noise when operated at the low exposure rates used in fluoroscopic procedures. The equipment-invasive instrumentation noise measures (in terms of electrons) are generally difficult to make and are potentially not as helpful in clinical practice as would be a direct radiological representation of such noise that may be determined in the field. In this work, we define a clinically relevant representation for instrumentation noise in terms of noise-equivalent detector entrance exposure, termed the instrumentation noise-equivalent exposure (INEE), which can be determined through experimental measurements of noise-variance or signal-to-noise ratio (SNR). The INEE was measured for various detectors, thus demonstrating its usefulness in terms of providing information about the effective operating range of the various detectors. A simulation study is presented to demonstrate the robustness of this metric against post-processing, and its dependence on inherent detector blur. These studies suggest that the INEE may be a practical gauge to determine and compare the range of quantum-limited performance for clinical x-ray detectors of different design, with the implication that detector performance at exposures below the INEE will be instrumentation-noise limited rather than quantum-noise limited

  4. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization

    International Nuclear Information System (INIS)

    Holmes, D.R. Jr.; Bove, A.A.; Wondrow, M.A.; Gray, J.E.

    1986-01-01

    A newly developed video x-ray progressive scanning system improves image quality, decreases radiation exposure, and can be added to any pulsed fluoroscopic x-ray system using a video display without major system modifications. With use of progressive video scanning, the radiation entrance exposure rate measured with a vascular phantom was decreased by 32 to 53% in comparison with a conventional fluoroscopic x-ray system. In addition to this substantial decrease in radiation exposure, the quality of the image was improved because of less motion blur and artifact. Progressive video scanning has the potential for widespread application to all pulsed fluoroscopic x-ray systems. Use of this technique should make cardiac catheterization procedures and all other fluoroscopic procedures safer for the patient and the involved medical and paramedical staff

  5. Comparison of x-ray diagnosis associated radiation exposures in Puerto Rico: 1973 vs. 1968

    International Nuclear Information System (INIS)

    Gileadi, M.; Gileadi, A.E.; Musalem, A.

    1975-01-01

    In general, it can be concluded that comparison of 1973 results obtained to date with parallel values for 1968 show a significant improvement in radiation protection practices in Puerto Rico. This improvement, which concerns the whole of society, is not only a result of technical upgrading of the diagnostic equipment, but also and perhaps more significantly, a result of the utmost efforts of professionals: doctors, radiologists and those in radiation protection, to use diagnostic x-rays judiciously, and to reduce the unavoidable doses to a minimum compatible with the diagnostic objective. (U.S.)

  6. Optimized control of X-ray exposure and image noise using a particular multislice CT scanner

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kakinuma, Ryutaro; Moriyama, Noriyuki; Koyama, Yoshihiro; Nagasawa, Hirofumi

    2008-01-01

    Patient dose reduction in computed tomography (CT) always results in a trade off between radiation exposure and image quality. There are few reports that estimate the relationship between image quality and X-ray exposure in CT examinations as one optimal index. The purpose of this study was to determine the optimal parameter settings enabling a low radiation exposure without compromising image quality using a particular 4-row multislice CT (MSCT) scanner (Aquilion VZ 4-slice CT scanner, Toshiba Medical Systems Corporation, Otawara, Tochigi, Japan). Normalized dose divided by image noise for helical pitches (nDNR: normalized dose to noise ratio) were calculated in consideration of beam collimation and tube current-time product. Optimal tube current-time product was calculated using the nDNR for the helical pitches based on user-defined standards of quality of the CT image. As a result, the nDNR proved to be well-supported to decrease the patient exposure in various exposure conditions of MSCT scans; however, the dose and image noise did not show a linear relation to the helical pitch. In conclusion, nDNR can be applied to patient dose reduction while keeping an acceptable image quality using a particular 4-row MSCT scanner. (author)

  7. Study of Syrian archaeological pottery by the combined application of thermoluminescence (TL) dating, X-ray fluorescence analysis and statistical multivariate analysis

    International Nuclear Information System (INIS)

    Bakraji, E.H.

    2012-01-01

    X-ray fluorescence method and the technique of thermoluminescence (TL) dating have been utilized for the study of archaeological pottery fragment samples, fairly representative of Romanian period between 1 st century B.C. and 4th century A.D, from Judaidet Yabous site, which is located north-west of Damascus city, Syria. Four samples were chosen randomly among the forty six samples for dating using thermoluminescence technique and the results were in good agreement with the date assigned by archaeologists. The samples were irradiated for 1000 s live time twice, first using a Mo X-ray Tube and second using a 109 Cd radioactive source. Fifteen elements (K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, Nb, and Pb) were determined. The elemental concentrations have been processed using two multivariate statistical methods. The purpose of the study was to characterize by means of elements contents the pottery paste from Judaidet Yabous archaeological site and providing new data to the Syrian databases for future studies. From an archaeological point of view the results indicated that most of the potteries, were locally produced. (author)

  8. Clinical applications of scanning electron microscopy and energy dispersive X-ray analysis in dermatology--an up-date

    International Nuclear Information System (INIS)

    Forslind, B.

    1988-01-01

    Dermatological papers comprising scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) analysis data published 1983 through 1986 in international journals are reviewed, as an update to our 1984 paper on Clinical applications of scanning electron microscopy and X-ray microanalysis in dermatology. The present paper not only deals with a review of recent publications in this area but also presents the application of microincineration to hair and cryosectioned freeze-dried skin specimens. Examples of the increased contrast obtained in hair cross sections are presented and a discussion on the feasibility of microincineration at analysis of hair and skin cross sections is given. Particle probe analysis (EDX: energy dispersive X-ray analysis and PMP: proton microprobe analysis) as applied to hair and skin samples are presented with stress put on the proton probe analysis. The complementarity of EDX and PMP is demonstrated and future applications are suggested. 75 references

  9. Exposure to Spousal Violence in the Family, Attitudes and Dating Violence Perpetration Among High School Students in Port-au-Prince.

    Science.gov (United States)

    Gage, Anastasia J

    2016-09-01

    This study examined the associations of exposure to spousal violence in the family and personal and peer attitudes with dating violence (DV) perpetration among high school students in Port-au-Prince, Haiti. Participants were 342 high school students in Grades 10 to 12 who stated that they had ever been on a date. Multiple linear regression methods were used to examine correlates of the scale of DV perpetration. Findings showed that personal acceptance of DV mediated the association between exposure to wife-perpetrated and husband-perpetrated spousal violence in the family and DV perpetration for girls. Boys who were exposed to husband-perpetrated spousal violence in the family had significantly higher levels of psychological DV perpetration than those who were not. Contrary to expectations, exposure to wife-perpetrated spousal violence in the family was negatively associated with psychological and physical/sexual DV perpetration by boys, after controlling for other factors. Overall, perceived peer tolerance of DV was more strongly associated with DV perpetration than personal tolerance of DV, and was the only significant correlate of psychological DV perpetration for girls. Perceived peer attitudes also moderated the association between boys' exposure to spousal violence in the family and DV perpetration. Implications for future research and policy are discussed. © The Author(s) 2015.

  10. Device for measuring the exposure time in dental X-ray - Cronox

    International Nuclear Information System (INIS)

    Menezes, Claudio J.M.; Santos, Luiz A.P. dos

    2009-01-01

    The Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) developed a test device for monitoring the X-ray beam in dental equipment to its application in quality control programs. This device, called Odontologic Dosimetric Card (CDO of Cartao Dosimetrico Odontologico in Portuguese) uses thermoluminescent dosimeters (TLD) for the measurement of some parameters of the X-ray beam as the entrance surface dose, the peak tension and half value layer (HVL). Radiographic films record the size of the radiation field. However, the TLD does not allow the assessment of exposure time, a parameter that complements the requirements of the Diretrizes de Protecao Radiologica em Radiodiagnostico Medico e Odontologico of Department of Health in Brazil for such equipment. Thus was developed a system based on sensitivity to ionizing radiation of phototransistors for measurement of exposure time when a patient is put in a clinical dental radiography. The system, called CRONOX was sized to be inserted within the CDO. The results showed that the measuring error had developed for less than 3% when compared to reference values obtained with the Tektronix digital oscilloscope, TDS2022 model. The readings obtained with the CRONOX were also compared with the nominal values selected in the X-ray equipment and with the values measured with the instrument of trade PTW Diavolt Universal. The results showed that the measuring device developed showed a maximum deviation of 5.92% on the nominal value selected, while for the instrument of PTW was 17.86%. (author)

  11. Effects of embryonic and fetal exposure to x-ray, microwaves, and ultrasound

    International Nuclear Information System (INIS)

    Brent, R.L.

    1986-01-01

    Many professionals are unfamiliar with radiation biology or the quantitative nature of the risks. Frequently, microwave, ultrasound, and ionizing radiation risks are confused. Although it is impossible to prove no risk for any environmental hazard, it appears that exposure to microwave radiation below the maximal permissible levels present no measurable risk to the embryo. Ultrasound exposure from diagnostic ultrasonographic imaging equipment also is quite innocuous. It is true that continued surveillance and research into potential risks of these low-level exposures should continue, but at present ultrasound not only improves obstetric care but also reduces the necessity of diagnostic x-ray procedures. In the field of ionizing radiation, we have as good a comprehension of the biologic effects and the quantitative maximum risks as of any other environmental hazard. Although the animal and human data support the conclusion that no increases in the incidence of gross congenital malformations, intrauterine growth retardation, or abortion will occur with exposures less than 5 rad, that does not mean that there are definitely no risks to the embryo exposed to lower doses of radiation. Whether there exists a linear or exponential dose-response relationship or a threshold exposure for genetic, carcinogenic, cell-depleting, and life-shortening effects has not been determined. In establishing maximum permissible levels for the embryo at low exposures, refer to Tables 4, 5, 6, 8, and 9. It is obvious that the risks of 1-rad or 5-rad acute exposure are far below the spontaneous risks of the developing embryo because 15 per cent of human embryos abort, 2.7 to 3.0 per cent of human embryos have major malformations, 4 per cent have intrauterine growth retardation, and 8 to 10 per cent have early- or late-onset genetic disease. 98 references

  12. Exposure to Low-Dose X-Ray Radiation Alters Bone Progenitor Cells and Bone Microarchitecture.

    Science.gov (United States)

    Lima, Florence; Swift, Joshua M; Greene, Elisabeth S; Allen, Matthew R; Cunningham, David A; Braby, Leslie A; Bloomfield, Susan A

    2017-10-01

    Exposure to high-dose ionizing radiation during medical treatment exerts well-documented deleterious effects on bone health, reducing bone density and contributing to bone growth retardation in young patients and spontaneous fracture in postmenopausal women. However, the majority of human radiation exposures occur in a much lower dose range than that used in the radiation oncology clinic. Furthermore, very few studies have examined the effects of low-dose ionizing radiation on bone integrity and results have been inconsistent. In this study, mice were irradiated with a total-body dose of 0.17, 0.5 or 1 Gy to quantify the early (day 3 postirradiation) and delayed (day 21 postirradiation) effects of radiation on bone microarchitecture and bone marrow stromal cells (BMSCs). Female BALBc mice (4 months old) were divided into four groups: irradiated (0.17, 0.5 and 1 Gy) and sham-irradiated controls (0 Gy). Micro-computed tomography analysis of distal femur trabecular bone from animals at day 21 after exposure to 1 Gy of X-ray radiation revealed a 21% smaller bone volume (BV/TV), 22% decrease in trabecular numbers (Tb.N) and 9% greater trabecular separation (Tb.Sp) compared to sham-irradiated controls (P X-rays, whereas osteoclastogenesis was enhanced. A better understanding of the effects of radiation on osteoprogenitor cell populations could lead to more effective therapeutic interventions that protect bone integrity for individuals exposed to low-dose ionizing radiation.

  13. Effect of medical x-ray exposure on subsequent reproductive outcomes in scoliosis patients

    International Nuclear Information System (INIS)

    Visscher, W.A.

    1987-01-01

    A retrospective cohort study was done which was designed to assess the effects of medical x-ray exposure on cancer incidence among scoliosis patients. Although the primary purpose of the study was to assess cancer incidence, a secondary goal was to investigate whether diagnostic x-ray exposure is related to adverse reproductive events in the female subjects. A series of case-control analyses were done which were designed to assess these effects. Radiation exposure was measured both by total films received and by an estimate of the number of films received and by an estimate of the number of films which involved ovarian irradiation. Radiation appeared to increase a woman's risk of any adverse event in the overall analysis and her risk of a premature or low birth weight infant in the separate analyses. Radiation did not appear to be related to spontaneous abortion, complications of pregnancy or delivery or birth defects, although the results of the pregnancy complications analysis was suggestive

  14. A survey of medical exposure during X-ray diagnosis in Aomori

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    The purpose of this project was to survey medical exposure doses in Aomori Prefecture and compare them with guidance levels for X-ray diagnosis. A questionnaire survey on X-ray diagnosis was conducted at the main medical institutions in the prefecture. The questionnaire asked about technical conditions, and replies were obtained from 72.2% of the 79 institutions. The medical exposure doses (entrance surface doses) were calculated from the results of the questionnaires by the modified numerical dose determination (NDD) method. The distribution of the entrance surface doses at each site was calculated as the 1st quartile, median, 3rd quartile, average, standard deviation, maximum value and minimum value, by the quartile method. The distribution of exposed doses at each site showed a similar pattern with that of the national distribution. Some institutions used higher doses than the Japanese proposed guidance levels and International Atomic Energy Agency (IAEA) guidance levels. Re-assessment of radiographic conditions and photosensitive materials is needed to reduce exposure doses. (K.H.)

  15. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  16. Can polychlorinated biphenyl (PCB) signatures and enantiomer fractions be used for source identification and to age date occupational exposure?

    Science.gov (United States)

    Megson, David; Focant, Jean-Françios; Patterson, Donald G; Robson, Matthew; Lohan, Maeve C; Worsfold, Paul J; Comber, Sean; Kalin, Robert; Reiner, Eric; O'Sullivan, Gwen

    2015-08-01

    Detailed polychlorinated biphenyl (PCB) signatures and chiral Enantiomer Fractions (EFs) of CB-95, CB-136 and CB-149 were measured for 30 workers at a transformer dismantling plant. This was undertaken to identify sources of exposure and investigate changes to the PCB signature and EFs over different exposure periods. Approximately 1.5 g of serum was extracted and PCB signatures were created through analysis by comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC×GC-TOFMS) and EFs calculated following analysis by gas chromatography with high resolution mass spectrometry (GC-HRMS). A total of 84 PCBs were identified in the serum samples with concentrations of the 7 indicator PCBs ranging from 11-350 ng g(-1) of serum (1.2-39 μg g(-1) lipid). The PCB signatures were interpreted using principal component analysis (PCA) which was able to distinguish workers with background or recent minimal exposure from those with prolonged occupational exposure. Occupationally exposed individuals had a similar PCB profile to Aroclor A1260. However, individuals with prolonged exposure had depleted proportions of several PCB congeners that are susceptible to metabolism (CB-95, CB-101 and CB-151) and elevated proportions of PCBs that are resistant to metabolism (CB-74, CB-153, CB-138 and CB-180). The results also identified a third group of workers with elevated proportions of CB-28, CB-60, CB-66, CB-74, CB-105 and CB-118 who appeared to have been exposed to an additional source of PCBs. The results show near complete removal of the CB-95 E2 enantiomer in some samples, indicating that bioselective metabolism or preferential excretion of one enantiomer occurs in humans. By considering PCB concentrations along with detailed congener specific signatures it was possible to identify different exposure sources, and gain an insight into both the magnitude and duration of exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Radiation exposure of holding personnel involved in veterinary X-ray diagnosis

    International Nuclear Information System (INIS)

    Rothe, W.

    1977-01-01

    An account is given of radiation protection in the context of X-ray examination of small and big animals on the premises of seven reviewed veterinary centres. Also reported are the dosimetric results obtained from holding personnel involved in X-ray diagnosis of 319 big and 4,047 small animals. Infringement of valid regulations was quite often observed, in that animals are held in position in an inadequate way and by unauthorised persons. The measured results, however, have shown that the radiation exposure of vocationally exposed persons can be kept far below the maximum permissible equivalent doses, provided that all applicable rules of radiation protection are observed by those on duty. (author)

  18. Childhood cancer after prenatal exposure to diagnostic X-ray examinations in Britain

    International Nuclear Information System (INIS)

    Mole, R.H.

    1990-01-01

    Detailed data were provided by the Oxford Survey of Childhood Cancer OSCC on deaths from childhood cancer in Britain after irradiation of the fetus during diagnostic radiology of the mother. In each age group at death, 0-5, 6-9 and 10-15 years, excess cancer deaths decreased suddenly for births in and after 1958. A major factor was concerted action initiated in 1956 to reduce radiation exposure of fetal gonads for fear of genetic hazards. Dose reduction was achieved during 1957 and early 1958 by reducing the rising rate of obstetric radiography and by virtually abandoning pelvimetry as that had been understood. In the 1970s the rate of X-raying increased again and so did cancer risk but not significantly. Direct evidence that diagnostic X-rays can cause childhood cancer is the similar excess rate per X-ray in twins and singleton births when X-raying rate is 5-6 times higher in twins. (author)

  19. Radiation exposure of the Yazd Population from medical conventional X-ray examinations

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Zare, M. H.; Dashti, M. H.

    2007-01-01

    Radiation dose knowledge through X-ray examinations and their distribution in Iran provides useful guidance on patient dose reduction. The results of the entrance skin dose (ESD s ) of five common radiographs in all radiology centers in Yazd province were reported in our previous study (2003). In the present study we have evaluated the collective effective dose of conventional X-ray examinations, as well as the annual per caput of Yazd population.Materials and Methods: The annual frequencies of 18 different types of conventional radiology examinations during April 2005 to March 2006 were recorded from all 35 radiology centers in Yazd province. The exposure conditions consisted of kVp, mAs, and Focus surface distance (FSD) of the examinations for the mode of exposure in each X-ray unit. 620 ESD were measured by diode dosimeter in 35 hospitals and clinics. The real exposure kVp for each radiology unit was measured by a Molt-0-Meter. The conversion coefficient (effective dose - ESD ratio) for each radiology examination was determined by using SR262 tables. Finally, the patients' effective dose was calculated by multiplying the conversion factor to the ESD. Results: The patients' annual collective effective dose due to the conventional radiology examinations was 31.159 man-Sv (0.03 mSv per inhabitant). The frequency of examinations was 311813 i.e. 0.36 examinations per head of the population for one year. Conclusion: According to our findings, the effective per caput dose seems to be optimally relative to HCL-II countries, which may be due to low mean effective dose that could obscure high examination frequency. The number of radiology conventional examinations and frequency of radiologist per1000 population of Yazd was more and lower than HCL-II countries respectively. Thus the justification of radiography requests in this province must be revised

  20. ANATOMICAL DISPOSITION OF CARPAL BONES OF GOLDEN RETRIEVER DOG BY X-RAY EXPOSURE

    Directory of Open Access Journals (Sweden)

    R. Mandal

    2012-07-01

    Full Text Available The present study was conducted to know the general disposition of bones in carpal region of experimental dogs by X-ray study with an objective that the findings will facilitate to have an in-depth knowledge about the proper positioning of the carpal bones for surgical management of fractures and different types of bone deformities in dogs. In the present study, the anatomical disposition and arrangement pattern of carpal bones playing a pivotal role in providing the structural conformity in the limbs of Golden Retriever dog has been thoroughly confirmed by Xray exposure.

  1. DNA Topoisomerase-I Inhibition due to Exposure to X-Rays

    International Nuclear Information System (INIS)

    Daudee, R.; Gonen, R.; German, U.; Orion, I.; Priel, E.

    2014-01-01

    In events such as radiological terrorism, accidents involving radioactive materials and occupational exposures, there is a great need to identify exposures to relatively low radiation levels. In many situations, the evaluation of radiation doses is not possible using physical dosimeters as they are not worn, and it is desirable to achieve this based on sensitive biomarkers (1, 2, 3). DNA Topoisomerase-I (Topo-I) is an essential nuclear enzyme that is responsible for the topological state of the DNA. The enzyme is involved in a variety of DNA transactions, including replication, transcription, recombination and DNA repair (4,5). The aim of the present work was to investigate the influence of X-ray radiation on the catalytic activity of this enzyme, and to evaluate its applicability as a biological dosimeter

  2. Thermoluminescence dating

    International Nuclear Information System (INIS)

    Price, D.M.

    1999-01-01

    Thermoluminescence (TL) dating of sediments depends upon the acquisition and long term stable storage of TL energy by crystalline minerals contained within a sedimentary unit. This energy is stored in the form of trapped electrons and quartz sand is the most commonly used mineral employed in the dating process. Prior to the final depositional episode it is necessary that any previously acquired TL is removed by exposure to sunlight. After burial the TL begins to build up again at a rate dependent upon the radiation flux delivered by long-lived isotopes of uranium, thorium and potassium. The presence of rubidium and cosmic radiation generally play a lesser but contributory roll, and the total radiation dose delivered to the TL phosphor is modified by the presence of water. The period since deposition is therefore measured by determining the total amount of stored TL energy, the palaeodose (P), and the rate at which this energy is acquired, the annual radiation dose (ARD). TL dating may be applied to eolian, fluvial, coastal and in some cases, marine sediments. the technique is also successfully applied to volcanic materials and to a certain extent to archeological specimens

  3. Real-Time Aircraft Cosmic Ray Radiation Exposure Predictions from the NAIRAS Model

    Science.gov (United States)

    Mertens, C. J.; Tobiska, W.; Kress, B. T.; Xu, X.

    2012-12-01

    The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) is a prototype operational model for predicting commercial aircraft radiation exposure from galactic and solar cosmic rays. NAIRAS predictions are currently streaming live from the project's public website, and the exposure rate nowcast is also available on the SpaceWx smartphone app for iPhone, IPad, and Android. Cosmic rays are the primary source of human exposure to high linear energy transfer radiation at aircraft altitudes, which increases the risk of cancer and other adverse health effects. Thus, the NAIRAS model addresses an important national need with broad societal, public health and economic benefits. There is also interest in extending NAIRAS to the LEO environment to address radiation hazard issues for the emerging commercial spaceflight industry. The processes responsible for the variability in the solar wind, interplanetary magnetic field, solar energetic particle spectrum, and the dynamical response of the magnetosphere to these space environment inputs, strongly influence the composition and energy distribution of the atmospheric ionizing radiation field. Real-time observations are required at a variety of locations within the geospace environment. The NAIRAS model is driven by real-time input data from ground-, atmospheric-, and space-based platforms. During the development of the NAIRAS model, new science questions and observational data gaps were identified that must be addressed in order to obtain a more reliable and robust operational model of atmospheric radiation exposure. The focus of this talk is to present the current capabilities of the NAIRAS model, discuss future developments in aviation radiation modeling and instrumentation, and propose strategies and methodologies of bridging known gaps in current modeling and observational capabilities.

  4. Modifications of γ-ray sensitivity of bacterial membranes by pre-exposure to light

    International Nuclear Information System (INIS)

    Misiti-Dorello, P.; Cancelliere, G.; De Martino, G.; Quintilini, M.

    1976-01-01

    The exposure of E. coli B/r cells to ultraviolet or to visible light prior to irradiation with γ-rays modifies the sensitivity of the cell membrane to radiation damage responsible for the intracellular K + content. Exposure of bacterial cells to sublethal doses of UV radiation increases their sensitivity to γ-induced membrane damage, while exposure to visible light has the opposite effect. In combined exposures, the visible light, either given before or after the UV always produces a strong photoprotective effect. In either case, the photosensitizing effect of UV is completely suppressed. The photoprotection decays with time if cell suspensions are left in the dark before γ-irradiation. At O 0 C, the half-life of the photoprotective effect is 25 min at pH 7 and 100 min at pH 7.5. The decay is due to the presence of oxygen. The light band responsible for the induction of photoprotection has been estimated to lie in the wavelenght region between 540 and 580 nm. (orig./MG) [de

  5. ABCC-JNIH adult health study Hiroshima and Nagasaki 1961 exposure to medical x-ray. Preliminary survey

    Energy Technology Data Exchange (ETDEWEB)

    Ishimaru, Toranosuke; Russell, W J

    1962-05-16

    A survey was conducted for three months among subjects seen in the medical clinics of ABCC, Hiroshima and Nagasaki, to determine the extent of medical x-ray received in ABCC and other hospitals and clinics. Emphasis was chiefly methodological to prepare for later studies designed to evaluate the contribution of medical x-ray to total radiation dose received by survivors of the atomic bombings and controls. The frequency, the institution in which the subject received x-ray, as well as the types of exposure were the prime considerations in the survey. The data were analyzed for each city by sex, age, and exposure status. 2 references, 5 figures, 11 tables.

  6. Exposure to Family Violence as a Predictor of Dating Violence and Child-to-Parent Aggression in Spanish Adolescents

    Science.gov (United States)

    Izaguirre, Ainhoa; Calvete, Esther

    2017-01-01

    Witnessing intimate partner violence (IPV) and child maltreatment may place children on a lifelong trajectory toward violence. The primary aim of this research was to examine the associations between exposure to violence at home and two forms of violence in close relationships in Spanish adolescents: child-to-parent violence (CPV) and dating…

  7. Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians

    Science.gov (United States)

    Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.

    2018-06-01

    The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (Pgroups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.

  8. Effects of pre-natal X-ray exposure on learning behaviour of mice

    International Nuclear Information System (INIS)

    Frank, P.; Faber, U.; Budny, T.

    1983-01-01

    The authors investigated whether prenatal X-raying affects the learning behaviour of mice. For this purpose they irradiated mice of strain C57BL/6Ffm with 130 r at different points of the fetal phase. Unirradiated mice served as controls. The animals underwent two learning test series of 14 days each teaching them optical signs. The results of the test series show a distinctly inferior learning ability in the animals exposed to pre-natal irradiation as compared to unirradiated controls. The extent of the reduction of the learning ability depends on the stage of the pregnancy at the time of X-ray exposure. The greatest difference as compared to non-irradiated mice occurred in the animals irradiated at the earliest stage (13th/14th day of pregnancy). The results of the other test groups (15th/16th and 17th/18th day of pregnancy) exhibited less distinct, but still significant differences to the controls. Exposure at the latest period (17th/18th day) coincided with the smallest difference. (orig./MG) [de

  9. Cellular oncogene expression following exposure of mice to γ-rays

    International Nuclear Information System (INIS)

    Anderson, A.; Woloschak, G.E.

    1991-01-01

    We examined the effects of total body exposure of BCF1 mice to γ-rays (300 cGy) in modulating expression of cellular oncogenes in both gut and liver tissues. We selected specific cellular oncogenes (c-fos, c-myc, c-src, and c-H-ras), based on their normal expression in liver and gut tissues from untreated mice. As early as 5 min. following whole body exposure of BCF1 mice to γ-rays we detected induction of mRNA specific for c-src and c-H-ras in both liver and gut tissues. c-fos RNA was slightly decreased in accumulation in gut but was unaffected in liver tissue from irradiated mice relative to untreated controls. c-myc mRNA accumulation was unaffected in all tissues examined. These experiments document that modulation of cellular oncogene expression can occur as an early event in tissues following irradiation and suggest that this modulation may play a role in radiation-induced carcinogenesis

  10. Shorter exposures to harder X-rays trigger early apoptotic events in Xenopus laevis embryos.

    Directory of Open Access Journals (Sweden)

    JiaJia Dong

    Full Text Available BACKGROUND: A long-standing conventional view of radiation-induced apoptosis is that increased exposure results in augmented apoptosis in a biological system, with a threshold below which radiation doses do not cause any significant increase in cell death. The consequences of this belief impact the extent to which malignant diseases and non-malignant conditions are therapeutically treated and how radiation is used in combination with other therapies. Our research challenges the current dogma of dose-dependent induction of apoptosis and establishes a new parallel paradigm to the photoelectric effect in biological systems. METHODOLOGY/PRINCIPAL FINDINGS: We explored how the energy of individual X-ray photons and exposure time, both factors that determine the total dose, influence the occurrence of cell death in early Xenopus embryo. Three different experimental scenarios were analyzed and morphological and biochemical hallmarks of apoptosis were evaluated. Initially, we examined cell death events in embryos exposed to increasing incident energies when the exposure time was preset. Then, we evaluated the embryo's response when the exposure time was augmented while the energy value remained constant. Lastly, we studied the incidence of apoptosis in embryos exposed to an equal total dose of radiation that resulted from increasing the incoming energy while lowering the exposure time. CONCLUSIONS/SIGNIFICANCE: Overall, our data establish that the energy of the incident photon is a major contributor to the outcome of the biological system. In particular, for embryos exposed under identical conditions and delivered the same absorbed dose of radiation, the response is significantly increased when shorter bursts of more energetic photons are used. These results suggest that biological organisms display properties similar to the photoelectric effect in physical systems and provide new insights into how radiation-mediated apoptosis should be understood and

  11. Methodological study on exposure date of Tiankeng by AMS measurement of in situ produced cosmogenic {sup 36}Cl

    Energy Technology Data Exchange (ETDEWEB)

    Dong Kejun [China Institute of Atomic Energy, P.O. Box 275(50), Beijing 102413 (China); Li Shizhuo [China Institute of Atomic Energy, P.O. Box 275(50), Beijing 102413 (China); CNNC China North Nuclear Fuel Company Ltd., Baotou 014035 (China); He Ming [China Institute of Atomic Energy, P.O. Box 275(50), Beijing 102413 (China); Sasa, Kimikazu [Tandem Accelerator Complex, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan); Matsushi, Yuki [Disaster Prevention Research Institute, Kyoto University (Japan); Huang Baojian [Institute of Karst Geology, Chinese Academy of Geological Sciences, Guilin 541004 (China); Ruan Xiangdong; Guan Yongjing [College of Physics Science and Technology, Guangxi University, Nanning 530004 (China); Takahashi, Tsutomu [Tandem Accelerator Complex, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan); Sueki, Keisuke [Graduate School of Pure and Applied Sciences, University of Tsukuba (Japan); Li Chaoli; Wu Shaoyong [China Institute of Atomic Energy, P.O. Box 275(50), Beijing 102413 (China); Wang Xianggao [China Institute of Atomic Energy, P.O. Box 275(50), Beijing 102413 (China); Institute of Karst Geology, Chinese Academy of Geological Sciences, Guilin 541004 (China); Shen Hongtao [China Institute of Atomic Energy, P.O. Box 275(50), Beijing 102413 (China); College of Physics and Technology, Guangxi Normal University, Guilin 541004 (China); Nagashima, Yasuo [Tandem Accelerator Complex, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan); Jiang Shan, E-mail: jiangs@ciae.ac.cn [China Institute of Atomic Energy, P.O. Box 275(50), Beijing 102413 (China)

    2013-01-15

    Tiankeng is a typical Karst relief of the late Quaternary Period. Studies on the exposure ages of Tiankeng are very important in geographical research to elucidate the formation condition, the developing process, and the features of biological species. {sup 36}Cl on the surface layer of the rupture cross-section of Tiankeng is largely produced by cosmogenic high-energy neutron induced reactions {sup 40}Ca(n, {alpha}p) and {sup 39}K(n, {alpha}), and has accumulated since the formation of the Tiankeng. Low-energy neutron reaction {sup 35}Cl(n, {gamma}) contributes a small portion of {sup 36}Cl. In this work, the concentration of the cosmogenic {sup 36}Cl in rock samples taken from Dashiwei Tiankeng, Leye County, Guangxi Zhuang Autonomous Region, China, was measured jointly by Accelerator Mass Spectrometry (AMS) laboratories of CIAE and University of Tsukuba in an effort to estimate the formation time (or exposure age) of the Tiankeng. The results show that the exposure time of Da Shiwei Tiankeng is about 26 {+-} 9.6 ka (without erosion correction). The sampling strategy and procedures, experimental set-up, and preliminary results will be presented in detail.

  12. A synchrotron-based X-ray exposure station for radiation biology experiments

    International Nuclear Information System (INIS)

    Thompson, A.C.; Blakely, E.A.; Bjornstad, K.A.; Chang, P.Y.; Rosen, C.J.; Schwarz, R.I.

    2007-01-01

    Synchrotron X-ray sources enable radiation biology experiments that are difficult with conventional sources. A synchrotron source can easily deliver a monochromatic, tunable energy, highly collimated X-ray beam of well-calibrated intensity. An exposure station at beamline 10.3.1 of the Advanced Light Source (ALS) has been developed which delivers a variable energy (5-20 keV) X-ray fan beam with very sharp edges (10-90% in less than 3 μm). A series of experiments have been done with a four-well slide where a stripe (100 μm widex18 mm long) of cells in each well has been irradiated and the dose varied from well to well. With this facility we have begun a series of experiments to study cells adjacent to irradiated cells and how they respond to the damage of their neighbors. Initial results have demonstrated the advantages of using synchrotron radiation for these experiments

  13. A synchrotron-based X-ray exposure station for radiation biology experiments

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, A.C. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States)], E-mail: acthompson@lbl.gov; Blakely, E.A.; Bjornstad, K.A. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States); Chang, P.Y. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States); SRI International, Menlo Park, CA (United States); Rosen, C.J.; Schwarz, R.I. [Division of Life Sciences, Lawrence Berkeley National Laboratory, Bld. 50A-6120, Berkeley, CA 94720 (United States)

    2007-11-11

    Synchrotron X-ray sources enable radiation biology experiments that are difficult with conventional sources. A synchrotron source can easily deliver a monochromatic, tunable energy, highly collimated X-ray beam of well-calibrated intensity. An exposure station at beamline 10.3.1 of the Advanced Light Source (ALS) has been developed which delivers a variable energy (5-20 keV) X-ray fan beam with very sharp edges (10-90% in less than 3 {mu}m). A series of experiments have been done with a four-well slide where a stripe (100 {mu}m widex18 mm long) of cells in each well has been irradiated and the dose varied from well to well. With this facility we have begun a series of experiments to study cells adjacent to irradiated cells and how they respond to the damage of their neighbors. Initial results have demonstrated the advantages of using synchrotron radiation for these experiments.

  14. Feasibility of applying gamma irradiation as disinfestation technique on date fruits in respect to nutritional value that is affected by disinfesting gamma ray doses

    International Nuclear Information System (INIS)

    Ahmed, El-Sayed S.

    1976-01-01

    Infested and non-infested dry date fruits (Phonex dactylifera), Abrimi variety (9.2% moisture), with Ephestia cautella Walker were irradiated for 0, 15, 20 and 40 Krad gamma ray doses emitted from Co-60 source with 1.36 x 10-rad/h. as a dose rate. Irradiated fruits were stored at room temperature, at 20-25 0 C and 85-95% R.H., in packages to avoid reinfestation. A dose of 20 Krad is 100 percent effective in preventing the emergency of eggs, larva, and pupae in fruits as reflected by zero per cent emergency count for live adults. Also, this dose was found to be lethal for adult stage of the insect. On the other hand, 2 Krad dose does not produce significant changes in the nutritional qualities of fruits, as measured by chemical analytical means for carbohydrates, protein and amino acids, directly after irradiation as well as at 2, 4 and 6 months storage. The triangular tests show that irradiation treatments even with 4 Krad exerted no determinal effect upon the sensory qualities of stored irradiated date fruits. These results point out the feasibility of applying gamma irradiation, 20 Krad, as disinfestation technique against Ephestia cautella Walker in dry date fruits without exerting any effect on the nutritional value

  15. Risk evaluation of cosmic-ray exposure in long-term manned space mission

    International Nuclear Information System (INIS)

    Fujitaka, Kazunobu; Majima, Hideyuki; Ando, Koichi; Yasuda, Hiroshi; Suzuki, Masao

    1999-03-01

    Long-term manned space missions are planned to be implemented within the first two decades of the 21st century. The International Space Station (ISS) will be ready to run, and a plan to visit Mars is also under way. Humans will live in space for long periods of time and we are planning to do experiments in space to examine various aspects of space science. The main risk in long-term manned space missions is large exposure to space radiation. Human safety must be ensured in space where exposure to cosmic rays is almost 1 mSv a day. As such missions will inevitably result in significant exposure for astronauts, there is increasing need to protect them adequately based on both physical and biological knowledge. A good method to evaluate realistic risk associated with space missions will be in urgent demand. At the National Institute of Radiological Sciences (NIRS), Chiba, Japan, a research institutes of the Science Technology Agency of Japan, high energy cosmic radiation can be simulated only with heavy ion irradiation accelerated by the particle accelerator, Heavy Ion Medical Accelerator (HIMAC). Research to evaluate risk of space radiation, including physical measurement techniques, protective effects, biological effects and risk adjustment, aging, neuronal cell damage and cancer risk are undergoing. We organized a workshop of the latest topics and experimental results of physics and biology related to space radiation supported by Japan Science and Technology Corporation (JST). This workshop was held as a satellite meeting associated with the 32nd Committee on Space Research (COSPAR) Scientific Assembly (Nagoya, July 12-19th, 1998). This volume is an extended proceedings of the workshop. The proceedings contain six main subjects covering the latest information on Risk Evaluation of Cosmic-Ray Exposure in Long-Term Manned Space Mission'. 1. Risk Estimation of Heavy Ion Exposure in Space. 2. Low Dose-Rate Effects and Microbeam-Related Heavy Ions. 3. Chromosome and

  16. Study on exposures in incidents situations involving X-ray generators of industrial use

    International Nuclear Information System (INIS)

    Rios, Paulo B.; Rios, Denise A. da S.

    2014-01-01

    Case studies of accidents involving radiation sources provides valuable information for the improvement of equipment and procedures to be adopted to prevent their recurrence. Therefore, they are recommended as part of the licensing process of radiative facilities. However, when the equipment has no radiological protection requirements or have no record of accidents, an effective method to appropriate this knowledge necessary to improvements of process and project is the investigation of reported incidents and the proposition limit situations where exposures unlikely and even low intensity can occur. This work reviews incidents in X-ray equipment and thickness meters. Emergency situations are also studied in this type of equipment and in an accelerator of electrons self-shielded for curing of paints and varnishes. The exposure estimates are calculated from data collected in workplaces on the distance and time for each proposed case. Although there is no severe consequences to occupational health, the results can be used to improve the quality of training for operators and maintenance technicians, for proposing of new alarm systems and emergency teams procedures and may serve as a warning in inadvertent and avoidable situations of unnecessary exposures

  17. Implementation of a primary standard for a x-ray exposure

    International Nuclear Information System (INIS)

    peixoto, J.G.P.

    1991-04-01

    In the scientific program of the National Laboratory for Ionizing Radiation Metrology of the Instituto de Radioprotecao e Dosimetria, which belongs to the Comissao Nacional de Energia Nuclear, a free-air ionization chamber should be established as an exposure primary standard for X-rays of 100 K V to 250 K V of potential range. Preliminary results showed that the available free-air ionization chamber was suitable to be used. The absolute measurement of the radiation quantity exposure, is performed with a free-air ionization chamber. Its geometrical volume, which allows the determination of the air mass, is defined by the effective aperture area and by the length of the region where an electrical field is applied. Most of the ions produced in such volume are collected as an ionization current. Parameters related to the measurement of the quantity exposure were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation, beam homogeneity, influence of beam size and influences of temperature, humidity and atmospheric pressure. Preliminary determination of correction factors has showed good results with 99.9% of repeatability and has demonstrated the reliability of the checked chamber as a standard instrument. (author)

  18. Theoretical determination of spectrum-exposure rate conversion operator of HPGe detector and its application to the measurement of environmental gamma-ray exposure rate

    International Nuclear Information System (INIS)

    Park, Ch.M.; Choi, B.I.; Kwak, S.S.; Ji, P.K.; Kim, T.W.; Park, Y.W.; Yoon, B.K.

    1993-01-01

    A conversion operator between spectrum and exposure rate, using a portable HPGe detector for environmental radiation monitoring, was determined theoretically under the assumption of uniform distribution of radiation source on the ground surface. The measurement results were compared with those of a pressurized ionization chamber. The results obtained with the HPGe detector were slightly lower. The method can be easily applied to any gamma ray detector to obtain a spectrum - exposure-rate conversion factor for computing the exposure rate of environmental gamma radiation. (N.T.) 15 refs.; 6 figs.; 3 tabs

  19. Exposure to power frequency magnetic fields suppresses X-ray-induced apoptosis transiently in Ku80-deficient xrs5 cells

    International Nuclear Information System (INIS)

    Tian, Furong; Nakahara, Takehisa; Yoshida, Masami; Honda, Naoko; Hirose, Hideki; Miyakoshi, Junji

    2002-01-01

    In an attempt to determine whether exposure to extremely low frequency (ELF) electromagnetic fields can affect cells, Ku80-deficient cells (xrs5) and Ku80-proficient cells (CHO-K1) were exposed to ELF electromagnetic fields. Cell survival, and the levels of the apoptosis-related genes p21, p53, phospho-p53 (Ser 15 ), caspase-3 and the anti-apoptosis gene bcl-2 were determined in xrs5 and CHO-K1 cells following exposure to ELF electromagnetic fields and X-rays. It was found that exposure of xrs5 and CHO-K1 cells to 60 Hz ELF electromagnetic fields had no effect on cell survival, cell cycle distribution and protein expression. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields for 5 h after irradiation significantly inhibited G 1 cell cycle arrest induced by X-rays (1 Gy) and resulted in elevated bcl-2 expression. A significant decrease in the induction of p53, phospho-p53, caspase-3 and p21 proteins was observed in xrs5 cells when irradiation by X-rays (8 Gy) was followed by exposure to 5 mT ELF magnetic fields. Exposure of xrs5 cells to the ELF electromagnetic fields for 10 h following irradiation significantly decreased X-ray-induced apoptosis from about 1.7% to 0.7%. However, this effect was not found in CHO-K1 cells within 24 h of irradiation by X-rays alone and by X-rays combined with ELF electromagnetic fields. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields following irradiation can affect cell cycle distribution and transiently suppress apoptosis by decreasing the levels of caspase-3, p21, p53 and phospho-p53 and by increasing bcl-2 expression

  20. Risk assessment of medical exposure in X-ray examinations of children

    Directory of Open Access Journals (Sweden)

    I. G. Shatsky

    2017-01-01

    Full Text Available The use of the effective dose (the concept of which was developed for radiation protection of workers and public and the nominal risk coefficients, averaged by sex and age, to assess the radiation risks of medical exposure has some significant limitations. Age and sex distribution of the staff and the entire population may be quite different from the sex and age distribution of patients undergoing medical exposure. Moreover, the structure of the age and sex of patients may be different for various medical examinations. There are simplified methods for evaluating individual risk for patients undergoing medical exposure. The methods are based on the effective dose evaluation and those take in to account age and gender. A more accurate assessment of lifetime risk of delayed stochastic effects for health of the patient is achieved by using the organ doses and the age and gender risk factors. The aim of this work was evaluation of the lifetime risk of long-term stochastic health effects for different gender and age groups of children undergoing various radiographic investigations by using organ doses and the age and gender risk factors, and subsequent classification in accordance with generally accepted international risk scale. Data from surveys of33 X-ray units in 29 specialized pediatric health care organizations in Russia were used in the work. Organ doses and patient’s effective doses were calculated on the basis of the defined for each x-ray machine typical modes for the 12 radiographic procedures (X-ray exam of the skull, chest, cervical spine, thoracic spine, lumbar spine–all in two projections – of the abdomen and pelvis – both in one projectionusing a computer program PCXMC., Radiation risks for selected studies were estimated using the obtained organ doses and the age and gender risk factors calculated for the Russian population. The radiation risks were classified according to the international scale of the risks. It was found

  1. Exposure to hazardous substances in Cathode Ray Tube (CRT) recycling sites in France

    Energy Technology Data Exchange (ETDEWEB)

    Lecler, Marie-Thérèse, E-mail: marie-therese.lecler@inrs.fr; Zimmermann, François; Silvente, Eric; Clerc, Frédéric; Chollot, Alain; Grosjean, Jérôme

    2015-05-15

    Highlights: • Chemical risks were assessed in the nine cathode ray tube screens recycling facilities. • The main hazardous agents are dust containing lead, cadmium, barium and yttrium. • Exposure and pollutant levels are described for different operations and processes. • All the operations and processes are concerned by significant levels of pollutants. • We suggest recommendations to reduce chemical risk. - Abstract: The Waste Electrical and Electronic Equipment (WEEE) or e-waste recycling sector has grown considerably in the last fifteen years due to the ever shorter life cycles of consumables and an increasingly restrictive policy context. Cathode Ray Tubes (CRTs) from used television and computer screens represent one of the main sources of e-waste. CRTs contain toxic materials such as lead, cadmium, barium, and fluorescent powders which can be released if recycling of CRTs is not appropriate. Exposure to these harmful substances was assessed in nine workshops where CRT screens are treated. Particulate exposure levels were measured using a gravimetric method and metals were analysed by plasma emission spectrometry. The maximum levels of worker exposure were 8.8 mg/m{sup 3}, 1504.3 μg/m{sup 3}, 434.9 μg/m{sup 3}, 576.3 μg/m{sup 3} and 2894.3 μg/m{sup 3} respectively for inhalable dust, barium, cadmium, lead and yttrium. The maximum levels of airborne pollutants in static samples were 39.0 mg/m{sup 3}, 848.2 μg/m{sup 3}, 698.4 μg/m{sup 3}, 549.3 μg/m{sup 3} and 3437.9 μg/m{sup 3} for inhalable dust, barium, cadmium, lead and yttrium. The most harmful operations were identified, and preventive measures for reducing the chemical risk associated with screen recycling were proposed. Workplace measurements were used to define recommendations for reducing the chemical risks in CRT screens recycling facilities and for promoting the design and development of “clean and safe” processes in emerging recycling channels.

  2. Dating Violence

    Science.gov (United States)

    ... for Teens / Dating Violence Bulletins for Teens: Dating Violence What is it? If you are a victim ... often. If You Are a Victim of Dating Violence, You Might… Think it's your fault. Feel angry, ...

  3. Comparison of late effects of single x-ray exposure, chronic tritiated water ingestion, and chronic cesium-137 gamma exposure in mice

    International Nuclear Information System (INIS)

    Carsten, A.L.; Cronkite, E.P.

    1979-01-01

    There is concern over the possible late effects resulting from chronic exposure to tritiated water, a primary by-product of power reactors. We are comparing the genetic and somatic effects of tritiated water ingestion to acute x-ray or chronic cesium-137 gamma-ray exposures. Eight week old mice were maintaned on tritiated water in concentrations of 0.3, 1.0, and 3.0 μCi/ml. Identical animals received cesium-137 gamma exposures equivalent to that from the tritiated water. At 4 week intervals, animals were sacrificed and the hematopoietic stem cell content and cellularity of the bone marrow determined. For comparison of acute and chronic effects, one group of mice received a single whole-body x-ray exposure of 525 rads. The x-irradiated animals showed an immediate sharp decrease in marrow cellularity followed by gradual return to normal levels, with a lifelong reduction in number of marrow stem cells. Animals exposed to the two higher concentrations of tritiated water showed only slight reductions in marrow cellularity, with a lifelong reduction in hematopoietic stem cells in the bone marrow. Comparison of the external gamma exposures to chronic tritiated water ingestion indicates similar patterns. Maintenance of normal cellularity with a reduced number of stem cells in x-rayed animals was shown by tritiated thymidine cytocide to be due to the reduction in number of stem cells in the resting G/sub O/ stage. At this time it is not possible to determine whether there is a significant difference in relative biological effectiveness of tritiated water compared to cesium-137 gamma rays; however, indications are that they are similar

  4. Improved model for solar cosmic ray exposure in manned Earth orbital flights

    International Nuclear Information System (INIS)

    Wilson, J.W.; Nealy, J.E.; Atwell, W.; Cucinotta, F.A.; Shinn, J.L.; Townsend, L.W.

    1990-06-01

    A calculational model is derived for use in estimating Solar cosmic ray exposure to critical body organs in low-Earth orbit at the center of a large spherical shield of fixed thickness. The effects of the Earth's geomagnetic field and the astronauts' self-shielding are evaluated explicitly. The geomagnetic field model is an approximate tilted eccentric dipole with geomagnetic storms represented as a uniform-impressed field. The storm field is related to the planetary geomagnetic index K(sub p). The code is applied to the Shuttle geometry using the Shuttle mass distribution surrounding two locations on the flight deck. The Shuttle is treated as pure aluminum and the astronaut as soft tissue. Short-term, average fluence over a single orbit is calculated as a function of the location of the lines of nodes or long-term averages over all lines of nodes for a fixed inclination

  5. Gamma-ray energy absorption and exposure buildup factor studies in some human tissues with endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Kurudirek, Murat, E-mail: mkurudirek@gmail.co [Faculty of Science, Department of Physics, Ataturk University, 25240 Erzurum (Turkey); Dogan, Bekir [Faculty of Science, Department of Physics, Ataturk University, 25240 Erzurum (Turkey); Ingec, Metin [Faculty of Medicine, Department of Obstetrics and Gynecology, Ataturk University, 25240 Erzurum (Turkey); Ekinci, Neslihan; Ozdemir, Yueksel [Faculty of Science, Department of Physics, Ataturk University, 25240 Erzurum (Turkey)

    2011-02-15

    Human tissues with endometriosis have been analyzed in terms of energy absorption (EABF) and exposure (EBF) buildup factors using the five-parameter geometric progression (G-P) fitting formula in the energy region 0.015-15 MeV up to a penetration depth of 40 mfp (mean free path). Chemical compositions of the tissue samples were determined using a wavelength dispersive X-ray fluorescence spectrometer (WDXRFS). Possible conclusions were drawn due to significant variations in EABF and EBF for the selected tissues when photon energy, penetration depth and chemical composition changed. Buildup factors so obtained may be of use when the method of choice for treatment of endometriosis is radiotherapy.

  6. Analysis of chromosomal abnormalities: a study of partial exposure to X-rays

    International Nuclear Information System (INIS)

    Andrade, Aida M.G. de; Mendes, Mariana E.; Mendonça, Julyanne C.G.; Melo, Laís; Hwang, Suy; Santos, Neide; Lima, Fabiana F. de; Centro Regional de Ciências Nucleares; Universidade Federal de Pernambuco

    2017-01-01

    Biological dosimetry is used in case of supposed accidental overexposure. The most commonly used biomarkers for assessing the absorbed dose are unstable chromosomal abnormalities. In a case of a partial body exposure, the frequencies of those abnormalities varies according to the area of the exposed body and may be substantially different from a total exposure of the body with an identical dose. The present study aimed to evaluate the frequency of chromosomal changes simulating, with blood samples, partial (25%, 50%) and full body irradiation (100%) in X-ray beam. The irradiation was performed at Metrology Service (CRCN-NE / CNEN) with a bundle of 250kVp X-rays, resulting in the absorbed dose of 1.0 Gy. Prior to obtain the metaphases, irradiated blood was mixed with non-irradiated blood, and then the mitotic metaphases for the chromosomal analyzes were obtained by culturing lymphocytes and the slides were stained with 5% Giemsa. It was observed that there was an increase in dicentric frequency when the dose percentage increases in both subjects (0.024 and 0.049 in subject 1 and 0.016 and 0.038 in subject 2) after irradiation. The cellular distribution was 'contaminated' only at dose 25% of the first individual who had a prolongation of the distribution. The Qdr and Dolphin methods were used to estimate partial absorbed dose, but the Qdr method was not efficient and whereas the Dolphin method was efficient when the individual had a prolonged cell distribution. It is necessary to increase the number of observations to be sure of the observed behaviors. (author)

  7. Analysis of chromosomal abnormalities: a study of partial exposure to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Aida M.G. de; Mendes, Mariana E.; Mendonça, Julyanne C.G.; Melo, Laís; Hwang, Suy; Santos, Neide; Lima, Fabiana F. de, E-mail: aidamgandrade@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Centro Regional de Ciências Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Universidade Federal de Pernambuco (UFPE),Recife (Brazil). Centro de Biociências. Departamento de Genética

    2017-11-01

    Biological dosimetry is used in case of supposed accidental overexposure. The most commonly used biomarkers for assessing the absorbed dose are unstable chromosomal abnormalities. In a case of a partial body exposure, the frequencies of those abnormalities varies according to the area of the exposed body and may be substantially different from a total exposure of the body with an identical dose. The present study aimed to evaluate the frequency of chromosomal changes simulating, with blood samples, partial (25%, 50%) and full body irradiation (100%) in X-ray beam. The irradiation was performed at Metrology Service (CRCN-NE / CNEN) with a bundle of 250kVp X-rays, resulting in the absorbed dose of 1.0 Gy. Prior to obtain the metaphases, irradiated blood was mixed with non-irradiated blood, and then the mitotic metaphases for the chromosomal analyzes were obtained by culturing lymphocytes and the slides were stained with 5% Giemsa. It was observed that there was an increase in dicentric frequency when the dose percentage increases in both subjects (0.024 and 0.049 in subject 1 and 0.016 and 0.038 in subject 2) after irradiation. The cellular distribution was 'contaminated' only at dose 25% of the first individual who had a prolongation of the distribution. The Qdr and Dolphin methods were used to estimate partial absorbed dose, but the Qdr method was not efficient and whereas the Dolphin method was efficient when the individual had a prolonged cell distribution. It is necessary to increase the number of observations to be sure of the observed behaviors. (author)

  8. Radiation exposure of the UK population from medical and dental x-ray examinations

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.F.

    2002-03-01

    Knowledge of recent trends in the radiation doses from x-ray examinations and their distribution for the UK population provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimise the protection of the population in a cost-effective manner. In this report, the results of a recent survey of the frequency of medical and dental x-ray examinations in the UK and contemporary data on the radiation doses typically received by patients, are used to assess trends in the extent and the pattern of the population exposure. Individual patient doses, expressed in terms of the effective dose, range from a few microsieverts for simple radiographic examinations of the teeth, limbs or chest to tens of millisieverts for prolonged fluoroscopic procedures or some computed tomography (CT) examinations. A total of about 41.5 million medical and dental x-ray examinations are now conducted each year in the UK (0.70 examination per head of population) resulting in an annual per caput effective dose of 330 μSv. This is not significantly different from the previous rough estimate of 350 μSv for 1991. However, over the last ten years CT has more than doubled its contribution and is now responsible for 40% of the total dose to the population from medical x-rays. In contrast, the contribution from conventional radiographic and fluoroscopic examinations has nearly halved to about 44%. Interventional and angiographic procedures together contribute the remaining 16%. The annual per caput dose of 330 μSv is low in comparison with other countries having similarly developed systems of health care. This is due to both a lower frequency of x-ray examinations per head of population and generally lower doses in the UK than in other developed countries. However, the much increased contributions of CT, angiography and interventional procedures to the UK population dose indicate an urgent need to develop radiation protection and optimisation activities for

  9. Determination of gamma-ray exposure rate from short-lived fission products under criticality accident conditions

    International Nuclear Information System (INIS)

    Yanagisawa, Hiroshi; Ohno, Akio; Aizawa, Eijyu

    2002-01-01

    For the assessment of γ-ray doses from short-lived fission products (FPs) under criticality accident conditions, γ-ray exposure rates varying with time were experimentally determined in the Transient Experiment Critical Facility (TRACY). The data were obtained by reactivity insertion in the range of 1.50 to 2.93$. It was clarified from the experiments that the contribution of γ-ray from short-lived FPs to total exposure during the experiments was evaluated to be 15 to 17%. Hence, the contribution cannot be neglected for the assessment of γ-ray doses under criticality accident conditions. Computational analyses also indicated that γ-ray exposure rates from short-lived FPs calculated with the Monte Carlo code, MCNP4B, and photon sources based on the latest FP decay data, the JENDL FP Decay Data File 2000, well agreed with the experimental results. The exposure rates were, however, extremely underestimated when the photon sources were obtained by the ORIGEN2 code. The underestimation is due to lack of energy-dependent photon emission data for major short-lived FP nuclides in the photon database attached to the ORIGEN2 code. It was also confirmed that the underestimation arose in 1,000 or less of time lapse after an initial power burst. (author)

  10. Modulation of expression of genes encoding nuclear proteins following exposure to JANUS neutrons or γ-rays

    International Nuclear Information System (INIS)

    Woloschak, G.E.; Chang-Liu, Chin-Mei

    1994-01-01

    Previous work has shown that exposure of cells to ionizing radiations causes modulation of a variety of genes, including those encoding c-fos, interleukin-1, tumor necrosis factor, cytoskeletal elements, and many more. The experiments reported herein were designed to examine the effects of either JANUS neutron or γ-ray exposure on expression of genes encoding nucleus-associated proteins (H4-histone, c-jun, c-myc, Rb, and p53). Cycling Syrian hamster embryo cells were irradiated with varying doses and dose rates of either JANUS fission-spectrum neutrons or γ-rays; after incubation of the cell cultures for 1 h following radiation exposure, mRNA was harvested and analyzed by Northern blot. Results revealed induction of transcripts for c-jun, H4-histone, and Rb following γ-ray but not following neutron exposure. Interestingly, expression of c-myc was repressed following γ-ray but not following neutron exposure. Radiations at different doses and dose rates were compared for each of the genes studied

  11. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  12. Low-dose CT of the paranasal sinuses. Minimizing X-ray exposure with spectral shaping

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, Wolfgang [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany); Radiological Institute, Erlangen (Germany); May, Matthias; Saake, Marc; Brand, Michael; Uder, Michael; Lell, Michael [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany)

    2016-11-15

    Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192 x 0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 x 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDI{sub vol} 1.2 mGy vs. 4.4 mGy, p < 0.001). Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. (orig.)

  13. Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study

    International Nuclear Information System (INIS)

    Haeusler, Uwe; Brix, Gunnar; Czarwinski, Renate

    2009-01-01

    The purpose of this study was to analyse the radiation exposure of medical staff from interventional x-ray procedures. Partial-body dose measurements were performed with thermoluminescent dosimeters (TLD) in 39 physicians and nine assistants conducting 73 interventional procedures of nine different types in 14 hospitals in Germany. Fluoroscopy time and the dose-area product (DAP) were recorded too. The median (maximum) equivalent body dose per procedure was 16 (2,500) μSv for an unshielded person; the partial-body dose per procedure was 2.8 (240) μSv to the eye lens, 4.1 (730) μSv to the thyroid, 44 (1,800) μSv to one of the feet and 75 (13,000) μSv to one of the hands. A weak correlation between fluoroscopy time or DAP and the mean TLD dose was observed. Generally, the doses were within an acceptable range from a radiation hygiene point of view. However, relatively high exposures were measured to the hand in some cases and could cause a partial-body dose above the annual dose limit of 500 mSv. Thus, the use of finger dosimeters is strongly recommended. (orig.)

  14. New results regarding gonadal exposure in urologic X-ray diagnostics

    International Nuclear Information System (INIS)

    Barke, R.

    1977-01-01

    In a dosimetric study the radiation exposure of the gonads of 130 patients is determined with condenser ionization chambers in applying intravenous urography according to the valid examination standard of the Society of Medical radiology of the GDR. Shielding the gonads with 2 mm lead equivalent the gonad dose of men is less than 30 mrem, but more than 850 mrem without shielding. The gonad dose of women computationally determined from measurements of the surface dose, is about 1,200 mrem. As the radiation exposure due to each individual radiograph was recorded, the influencing factors (film size, distance of the lower field margin from the gonads) can be determined. For the statistically significant correlation between body weight and gonad dose regression equations are given which, with standard X-ray examinations, make it possible to calculate the gonad dose for the individual case with a high degree of certainty. The analysis of intravenous urographic examinations shows that there is a greater share of female patients because this type of examination is often used as an additional diagnostic procedure in case of gynaecologic diseases. Problems of exact dosimetry at the ovary can hardly be solved

  15. Comparison of gamma-ray exposure rate measurements at Bikini Atoll

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Crites, T.R.

    1975-01-01

    A radiological survey of Bikini and Eneu Islands of the Bikini Atoll was conducted during June 1975 to assess the potential radiation doses that may be received by the returning Bikinians. Bikini Atoll was one of the U.S. nuclear weapons testing sites in the Pacific. An integral part of the survey included measurements of the gamma-ray exposure rates at 1 m above the ground with portable NaI instruments at nearly 2700 locations on the two islands. For comparison purposes, similar measurements were made with a pressurized ion chamber at approximately 200 locations, and with LiF and CaF 2 :Dy thermoluminescent dosimeters (TLDs) at 80 locations. The results indicate that the NaI scintillators overresponded because of their nonlinear energy characteristics. The responses of the LiF dosimeters and the pressurized ion chamber agreed to within 13 percent. Attenuation studies with LiF TLDs indicated that roughly 25 percent of the total free air exposure rate at 1 m was due to beta radiation

  16. Cytogenetic analysis in peripheral blood lymphocytes after arteriography (exposure to X-rays and contrast medium)

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Popova, L.; Hristova, R.; Hadjidekov, V.

    2006-01-01

    Full text: The purpose of our study is to investigate the cytogenetic effects in peripheral blood lymphocytes of 29 patients who had undergone diagnostic angiography. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13 and 68 years). Cytogenetic analysis was performed in peripheral lymphocytes before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03 - 0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency was used as biomarkers of genotoxicity. The estimated frequency of chromosomal aberrations and micronuclei in peripheral blood lymphocytes of patients after arteriography examination is significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations nearly double after examination and remained constant at 24h analysis. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase of the cytogenetic injury in peripheral blood lymphocytes

  17. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  18. Chemical U-Th-Pb dating of monazite by 3D-Micro x-ray fluorescence analysis with synchrotron radiation

    DEFF Research Database (Denmark)

    Schmitz, Susanne; Möller, Andreas; Wilke, Max

    2009-01-01

    A confocal set-up for three-dimensional (3D) micro X-ray fluorescence (micro-XRF) was used at the mySpot beamline at BESSY II, which allows compositional depth profiling for various applications. We present results obtained with a confocal 3D micro-XRF set-up for chemical age dating using the U, Th...... and Pb concentrations of monazite within rock thin sections. The probing volume was determined to be approximately 21 × 21 × 24 µm3 for W-La using an excitation energy of 19 keV. The relative detection limits particularly for Pb are below 10 ppm (for counting times of 1000 s). Therefore, this 3D micro...... of ages, varying from 20 Ma to 1.82 Ga. Reference materials (GM3, F6, 3345) can be reproduced within error. The spread in the ages of all points determined by 3D micro-XRF is within 8 % of the isotopic reference value. The average 3D micro-XRF dates reproduce the reference ages with discrepancies between...

  19. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.

    2014-11-01

    In order to evaluate the age from the equivalent dose and to obtain an optimized and efficient procedure for thermoluminescence (TL) dating, it is necessary to obtain the values of both the internal and the external dose rates from dated samples and from their environment. The measurements described and compared in this paper refer to bricks from historic buildings and a fine-grain dating method. The external doses are therefore negligible, if the samples are taken from a sufficient depth in the wall. However, both the alpha dose rate and the beta and gamma dose rates must be taken into account in the internal dose. The internal dose rate to fine-grain samples is caused by the concentrations of natural radionuclides 238U, 235U, 232Th and members of their decay chains, and by 40K concentrations. Various methods can be used for determining trace concentrations of these natural radionuclides and their contributions to the dose rate. The dose rate fraction from 238U and 232Th can be calculated, e.g., from the alpha count rate, or from the concentrations of 238U and 232Th, measured by neutron activation analysis (NAA). The dose rate fraction from 40K can be calculated from the concentration of potassium measured, e.g., by X-ray fluorescence analysis (XRF) or by NAA. Alpha counting and XRF are relatively simple and are accessible for an ordinary laboratory. NAA can be considered as a more accurate method, but it is more demanding regarding time and costs, since it needs a nuclear reactor as a neutron source. A comparison of these methods allows us to decide whether the time- and cost-saving simpler techniques introduce uncertainty that is still acceptable.

  20. [Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination].

    Science.gov (United States)

    Miyajima, Ryuichi; Fujibuchi, Toshioh; Miyachi, Yusuke; Tateishi, Satoshi; Uno, Yoshinori; Amakawa, Kazutoshi; Ohura, Hiroki; Orita, Shinichi

    2018-01-01

    Medical staffs like radiological technologists, doctors, and nurses are at an increased risk of exposure to radiation while assisting the patient in a position or monitor contrast medium injection during computed tomography (CT). However, methods to protect medical staff from radiation exposure and protocols for using radiological protection equipment have not been standardized and differ among hospitals. In this study, the distribution of scattered X-rays in a CT room was measured by placing electronic personal dosimeters in locations where medical staff stands beside the CT scanner gantry while assisting the patient and the exposure dose was measured. Moreover, we evaluated non-uniform exposure and revealed effective techniques to reduce the exposure dose to medical staff during CT. The dose of the scattered X-rays was the lowest at the gantry and at the examination table during both head and abdominal CT. The dose was the highest at the trunk of the upper body of the operator corresponding to a height of 130 cm during head CT and at the head corresponding to a height of 150 cm during abdominal CT. The maximum dose to the crystalline lens was approximately 600 μSv during head CT. We found that the use of volumetric CT scanning and X-ray protective goggles, and face direction toward the gantry reduced the exposure dose, particularly to the crystalline lens, for which lower equivalent dose during CT scan has been recently recommended in the International Commission on Radiological Protection Publication 118.

  1. Effect of continuous gamma-ray exposure on performance of learned tasks and effect of subsequent fractionated exposures on blood-forming tissue

    Science.gov (United States)

    Spalding, J. F.; Holland, L. M.; Prine, J. R.; Farrer, D. N.; Braun, R. G.

    1972-01-01

    Sixteen monkeys trained to perform continuous and discrete-avoidance and fixed-ratio tasks with visual and auditory cues were performance-tested before, during, and after 10-day gamma-ray exposures totaling 0, 500, 750, and 1000 rads. Approximately 14 months after the performance-test exposures, surviving animals were exposed to 100-rad gamma-ray fractions at 56-day intervals to observe injury and recovery patterns of blood-forming tissues. The fixed-ratio, food-reward task performance showed a transient decline in all dose groups within 24 hours of the start of gamma-ray exposure, followed by recovery to normal food-consumption levels within 48 to 72 hours. Avoidance tasks were performed successfully by all groups during the 10-day exposure, but reaction times of the two higher dose-rate groups in which animals received 3 and 4 rads per hour or total doses of 750 and 1000 rads, respectively, were somewhat slower.

  2. Alteration of the Carbon and Nitrogen Isotopic Composition in the Martian Surface Rocks Due to Cosmic Ray Exposure

    Science.gov (United States)

    Pavlov, A. A.; Pavlov, A. K.; Ostryakov, V. M.; Vasilyev, G. I.; Mahaffy, P.; Steele, A.

    2014-01-01

    C-13/C-12 and N-15/N-14 isotopic ratios are pivotal for our understanding of the Martian carbon cycle, history of the Martian atmospheric escape, and origin of the organic compounds on Mars. Here we demonstrate that the carbon and nitrogen isotopic composition of the surface rocks on Mars can be significantly altered by the continuous exposure of Martian surface to cosmic rays. Cosmic rays can effectively produce C-13 and N-15 isotopes via spallation nuclear reactions on oxygen atoms in various Martian rocks. We calculate that in the top meter of the Martian rocks, the rates of production of both C-13 and N-15 due to galactic cosmic rays (GCRs) exposure can vary within 1.5-6 atoms/cm3/s depending on rocks' depth and chemical composition. We also find that the average solar cosmic rays can produce carbon and nitrogen isotopes at a rate comparable to GCRs in the top 5-10 cm of the Martian rocks. We demonstrate that if the total carbon content in a surface Martian rock is <10 ppm, then the "light," potentially "biological" C-13/C-12 ratio would be effectively erased by cosmic rays over 3.5 billion years of exposure. We found that for the rocks with relatively short exposure ages (e.g., 100 million years), cosmogenic changes in N-15/N-14 ratio are still very significant. We also show that a short exposure to cosmic rays of Allan Hills 84001 while on Mars can explain its high-temperature heavy nitrogen isotopic composition (N-15/N-14). Applications to Martian meteorites and the current Mars Science Laboratory mission are discussed.

  3. Gardening process of lunar surface layer inferred from the galactic cosmic-ray exposure ages of lunar samples

    International Nuclear Information System (INIS)

    Iriyama, Jun; Honda, Masatake.

    1979-01-01

    From the cosmic-ray exposure age data, (time scale 10 7 - 10 8 years), of the lunar surface materials, we discuss the gardening process of the lunar surface layer caused by the meteoroid impact cratering. At steady state, it is calculated that, in the region within 10 - 50 m of the surface, a mixing rate of 10 -4 to 10 -5 mm/yr is necessary to match the exposure ages. Observed exposure ages of the lunar samples could be explained by the gardening effect calculated using a crater formation rate which is slightly modified from the current crater population data. (author)

  4. Fabrication of open-top microchannel plate using deep X-ray exposure mask made with silicon on insulator substrate

    CERN Document Server

    Fujimura, T; Etoh, S I; Hattori, R; Kuroki, Y; Chang, S S

    2003-01-01

    We propose a high-aspect-ratio open-top microchannel plate structure. This type of microchannel plate has many advantages in electrophoresis. The plate was fabricated by deep X-ray lithography using synchrotron radiation (SR) light and the chemical wet etching process. A deep X-ray exposure mask was fabricated with a silicon on insulator (SOI) substrate. The patterned Si microstructure was micromachined into a thin Si membrane and a thick Au X-ray absorber was embedded in it by electroplating. A plastic material, polymethylmethacrylate (PMMA) was used for the plate substrate. For reduction of the exposure time and high-aspect-ratio fast wet development, the fabrication condition was optimized with respect to not the exposure dose but to the PMMA mean molecular weight (M.W.) changing after deep X-ray exposure as measured by gel permeation chromatography (GPC). Decrement of the PMMA M.W. and increment of the wet developer temperature accelerated the etching rate. Under optimized fabrication conditions, a microc...

  5. Disorders of oxidation homeostasis in the blood and organs of rats under the influence of external x-ray exposure

    International Nuclear Information System (INIS)

    Uzlenkova, N.Je.

    2009-01-01

    The study was performed in the blood and organs (lungs and skin) of male rats weighing 160-180 g. Single external x-ray exposure to minimal and medial lethal doses causes stable disorders in oxidation homeostasis resulting in peroxidation state and development of chronic oxidative stress in the organism of the exposed rats.

  6. Dating Violence

    Science.gov (United States)

    Stader, David L.

    2011-01-01

    Dating violence is a form of student-on-student victimization and is a serious school safety issue. Research indicates that at a minimum, 10 percent of high school students are victims of dating violence in one form or another. Among female high school students that date, some data indicate that as many as 30 percent may be victims of dating…

  7. A mini X-ray generator as an alternative to a 90Sr/90Y beta source in luminescence dating

    DEFF Research Database (Denmark)

    Andersen, C.E.; Bøtter-Jensen, L.; Murray, A.S.

    2003-01-01

    We have carried out an investigation to test whether mini X-ray generators are a suitable alternative to radioactive sources in luminescence dating. The study has mainly been motivated by the need for high dose rates (similar to 1 Gy/s) to make dating of older samples using regeneration protocols...... with a sample of thermally sensitized sedimentary quartz suggest that we can use beta and X-ray irradiation interchangeably from the point of view of construction of growth curves by the single-aliquot regenerative-dose protocol. (C) 2003 Elsevier Science Ltd. All rights reserved....

  8. Exposure of patients and creation of system of quality assurance in conventional x-ray radiology in Lithuania

    International Nuclear Information System (INIS)

    Morkunas, G.; Ziliukas, J.

    1999-01-01

    One of the most important sources of exposure is medical application of ionizing radiation. X-ray examination comprise a significant part of medical exposure. Doses received by patients and quality of diagnostic images are to be optimized. Measurements of these doses were started by the Radiation Protection Centre in 1997. These measurements are performed in randomly selected x-ray departments all around Lithuania during examinations of chest and lumbar spine. Dose and parameters related to exposure and patient are registered. Quality control measurements by PMX-III are being performed on each x-ray machine used for examination. The results show that in many cases the guidance levels are of entrance surface dose for standard patient determined by the Basic Radiation Protection Standard of Lithuania are exceeded. Quality control of x-ray machines performed in 1997-1999 shows that more than 30% of these machines did not comply with the requirements though in many cases shortcomings are minor and easily removed. (au)

  9. Calculation of Buildup Factor for Gamma-ray Exposure in Two Layered Shields Made of Water and Lead

    International Nuclear Information System (INIS)

    Al-Saadi, A.H.

    2012-01-01

    The buildup factor for gamma ray exposure is most useful in calculations for biological protective shields.The buildup factors for gamma ray exposure were calculated in tow layered shields consist of water-lead and lead-water up to optical Thickness 20 mean free path (mfp) at gamma ray energies 1, 2 and 6MeV by using kalos's formula.The program has been designed to work at any atomic number of the attenuating medium, photon energy, slab thickness and and the arrangement of materials.The results obtained in this search leading to the buildup factor for gamma ray exposure at energies (1and2MeV) in lead-water were higher than the reverse case,while at energy 6 MeV the effect was opposite.The calculated data were parameterized by an empirical formula as a function of optical thickness of tow materials.The results obtained were in reasonable agreement with a previous work

  10. Radiopacity and microhardness changes and effect of X-ray operating voltage in resin-based materials before and after the expiration date

    Directory of Open Access Journals (Sweden)

    Tirapelli Camila

    2004-01-01

    Full Text Available This study observed alteration in the radiopacity and microhardness of expired resin-based materials compared to non-expired materials and the operating characteristics of the X-ray source used. Five 2 mm-thick cured specimens were prepared for each material: composite resins (P60®, Z100®, and a compomer (Dyract AP®. Radiopacity of the specimens was evaluated comparing the density of the resin-based material to an equivalent (mm density of a 99.5% pure aluminum step wedge using a transmission densitometer. Surface microhardness measurements were carried out using a calibrated Vickers indenter on three different points of the same surface. ANOVA and Tukey tests (pre-set alpha = 0.05 revealed that expired materials showed no significant change in radiopacity. One material (Filtek P60 demonstrated lower radiopacity with lower KVp. Change in microhardness wa s statistically significant for Z100: for this material, the microhardness after expiration was significantly lower than before the expiration date.

  11. Luminescence dating in archaeology

    International Nuclear Information System (INIS)

    Wintle, A.G.

    2001-01-01

    Thermoluminescence (TL) dating is routinely applied to burnt lithic material. Simple fires are capable of enabling stones weighing a few hundred grams to reach 450 o C, thus zeroing the TL signal. TL dates have been obtained for Upper and Lower Paleolithic sites in Europe and the Near East. TL dating continues to be used for dating pottery and for authentification of ceramic works of art. Some recent studies report the use of optically stimulated luminescence (OSL) (also know as photoluminescence) for dating very small samples of quartz, e.g. from small pieces of pottery or frm metallurgical slag The major recent advance has been in the development of a reliable laboratory procedure for using the OSL signal from quartz to obtain the past radiation exposure. The quartz OSL signal is extremely sensitive to light and is reduced to a negligible level on exposure to direct sunlight for radionuclides during burial, signal to date san.sized quartz grains extracted from sediments, The OSL signal is stimulated by 470 nm light from emitting diodes and the detected using flirters centred on 340 nm A similar signal can be obtained from feldspar grain when are exposed to infrared wavelengths around 880 nm. The infrared stimulated luminescence (IRSL) signals is also rapidly depleted by exposure to sunlight, and dating of colluvial deposits from archaeological sites has been reported

  12. Determination of existing exposure level of population during X ray investigations

    International Nuclear Information System (INIS)

    Tselinov, N.V.; Kudritskij, Yu.K.

    1978-01-01

    The distribution of X ray procedures among 500 inhabitants of the city of Vorkuta in 1975 is studied. Data on the distribution of the subjects by age group and type of X ray procedure are presented. The results obtained broaden the existing concepts on hygienic importance of radiation received by the population of the country during X ray studies. It is proposed that these results be used in developing methods for standardizing X ray procedures

  13. The timing and cause of glacial activity during the last glacial in central Tibet based on 10Be surface exposure dating east of Mount Jaggang, the Xainza range

    Science.gov (United States)

    Dong, Guocheng; Zhou, Weijian; Yi, Chaolu; Fu, Yunchong; Zhang, Li; Li, Ming

    2018-04-01

    Mountain glaciers are sensitive to climate change, and can provide valuable information for inferring former climates on the Tibetan Plateau (TP). The increasing glacial chronologies indicate that the timing of the local Last Glacial Maximum (LGM) recorded across the TP is asynchronous, implying different local influences of the mid-latitude westerlies and Asian Summer Monsoon in triggering glacier advances. However, the well-dated sites are still too few, especially in the transition zone between regions controlled by the two climate systems. Here we present detailed last glacial chronologies for the Mount Jaggang area, in the Xainza range, central Tibet, with forty-three apparent 10Be exposure-ages ranging from 12.4 ± 0.8 ka to 61.9 ± 3.8 ka. These exposure-ages indicate that at least seven glacial episodes occurred during the last glacial cycle east of Mount Jaggang. These include: a local LGM that occurred at ∼61.9 ± 3.8 ka, possibly corresponding to Marine Isotope Stage 4 (MIS 4); subsequent glacial advances at ∼43.2 ± 2.6 ka and ∼35.1 ± 2.1 ka during MIS 3; one glacial re-advance/standstill at MIS3/2 transition (∼29.8 ± 1.8 ka); and three glacial re-advances/standstills that occurred following MIS 3 at ∼27.9 ± 1.7 ka, ∼21.8 ± 1.3 ka, and ∼15.1 ± 0.9 ka. The timing of these glacial activities is roughly in agreement with North Atlantic millennial-scale climate oscillations (Heinrich events), suggesting the potential correlations between these abrupt climate changes and glacial fluctuations in the Mount Jaggang area. The successively reduced glacial extent might have resulted from an overall decrease in Asian Summer Monsoon intensity over this timeframe.

  14. Radiological protection in X-ray diagnosis: How to minimize the patient exposure in X-ray diagnosis

    International Nuclear Information System (INIS)

    Araujo, A.M.C. de.

    1986-01-01

    The principles involved in the radiation protection and the radiographic process are discussed. An adequate systematic work is presented, to achieve the main goal of the Radiation Protection that is, to irradiate the patient and the staff with lowest possible exposure. (M.A.C.) [pt

  15. X-ray exposure dose for the gonadal gland by the examination of computerized tomography and its protection

    International Nuclear Information System (INIS)

    Moriuchi, Iwao; Kaiya, Hisanori; Hirata, Toshifumi; Asada, Shuichi

    1978-01-01

    Computerized tomography (CT) is very useful for neuroradiological examination, and so it may possibly be used for screening tests. But x-ray exposure dose by a examination of CT is considerable, especially for the male gonadal gland. This study showed that the dose from a complete CT examination of 10 - 15 scans for a male gonadal gland was about 1,800 times more than a single plain neuroradiography. But by only a 0.07 mm lead equivalent protecter, the exposure dose resulting from CT for a gonadal gland could be reduced to 0.0 mrad. (auth.)

  16. Measurement of exposure buildup factors: The influence of scattered photons on gamma-ray attenuation coefficients

    Science.gov (United States)

    Mann, Kulwinder Singh

    2018-01-01

    Scattered photon's influence on measured values of attenuation coefficients (μm, cm2g-1) for six low-Z (effective atomic number) building materials, at three photon energies has been estimated. Narrow-beam transmission geometry has been used for the measurements. Samples of commonly used engineering materials (Cements, Clay, Lime-Stone, Plaster of Paris) have been selected for the present study. Standard radioactive sources Cs137 and Co60 have been used for obtaining γ-ray energies 661.66, 1173.24 and 1332.50 keV. The optical thickness (OT) of 0.5 mfp (mean free path) has been found the optimum optical thickness (OOT) for μm-measurement in the selected energy range (661.66-1332.50 keV). The aim of this investigation is to provide neglected information regarding subsistence of scattered photons in narrow beam geometry measurements for low-Z materials. The measurements have been performed for a wide range of sample-thickness (2-26 cm) such that their OT varies between 0.2-3.5 mfp in selected energy range. A computer program (GRIC2-toolkit) has been used for various theoretical computations required in this investigation. It has been concluded that in selected energy-range, good accuracy in μm-measurement of low-Z materials can be achieved by keeping their sample's OT below 0.5 mfp. The exposure buildup factors have been measured with the help of mathematical-model developed in this investigation.

  17. Risk of mammary oncogenesis from exposure to neutrons or gamma rays: experimental methodology and early findings

    International Nuclear Information System (INIS)

    Clifton, K.H.; Sridharan, B.N.; Gould, M.N.

    1976-01-01

    A project has been initiated to define the risk of oncogenesis per rad of high or low linear energy transfer (LET) radiation per surviving mammary cell and its modification by hormones. This work was undertaken because: (a) mammary carcinoma is the principle neoplastic disease of American women; (b) rats have been demonstrated to be remarkably susceptible to mammary oncogenesis following neutron irradiation; (c) rats are similar to women in the importance of hormones to carcinoma induction and progression in their mammary glands; and (d) exposure to neutrons is likely to increase with increasing use of nuclear reactors and development of neutron radiotherapy sources. To measure mammary cell survival and, ultimately, postirradiation repair capacity, the authors are developing an in-vivo end-point dilution assay based on the formation of glandular structures after the transplantation of known numbers of monodispersed rat mammary epithelial cell suspensions. Such grafts initially give rise to alveolus-like spheres and, with time, to complete glands. Growth and secretion can be stimulated in them by hormonal manipulation. In the short-term assays and the longer-term carcinogenesis studies, elevated endogenous mammotropic hormone, prolactin (MtH) levels have been induced by grafting of anterior pituitary tissue or of MtT (MtH-secreting pituitary tumours). Steroid hormone levels have been manipulated by surgical ablation or injection. Irradiations have been performed with a modified neutron fission spectrum generated by a Triga reactor, or with 137 Cs γ rays. Results with two inbred rat strains indicate: (a) that the type (carcinoma or fibroadenoma), incidence and latency of mammary tumours is markedly influenced by the circulating levels of MtH: and (b) that adrenal deficiency markedly enhances the induction of mammary carcinomas in irradiated rats with high endogenous MtH levels. Further studies are in progress. (author)

  18. MODERN PECULIARITIES OF THE MEDICAL EXPOSURE LEVELS FORMING OF THE TATARSTAN REPUBLIC POPULATION DURING X-RAY PROCEDURES IMPLEMENTATION

    Directory of Open Access Journals (Sweden)

    S. A. Ryzhkin

    2015-01-01

    Full Text Available The purpose. The purpose of the investigation is an assessment of the peculiarities of forming and registration of the collective doses of patients and the population of the Tatarsatan Republic (RT from medical exposure and the development of measures for optimization of this radiation factor.Materials and methods. The analysis is based on the forms of the Federal statistical observation № 3-DOZ «Data on the exposure doses to patients obtained during medical radiological examination» (form № 3-DOZ and radiation-hygienic passports of RT for the period from 2006 to 2013.The results. Annually in RT there is an increase of the number of performed X-ray procedures, which reached the value of 6279696 (1.64 procedures per resident per year in 2013. During the reporting period (from 2006 to 2013 the structure of the performed X-ray procedures has also changed. It is observed that the percentage of fluorography procedures in the overall structure decreased from 41.3% to 31.3% at the same time the level of absolute value of annually performed fluorography procedures is stable. There is an increase in the absolute number of radiographic procedures performed during the period from 2578754 to 4072810 X-rays per year, that is 1.58 times higher. Absolute and relative values related to X-ray fluoroscopy examinations decreased from 1.1% to 0.7%. In contrast, the absolute number of annually performed X-ray computed tomography examinations (CT has increased over the period by 3.3 times and percentage of CT in overall structure of X-ray procedure is 2.7%. The number of special investigations has increased in 2.1 times, but the relative value remained at average level of 0.4% on general background of the increasing of X-ray activity in the region. This fact influenced the change in the radiation-hygienic indexes of medical radiation exposure of the population of RT. According to №3-DOZ forms and radiation-hygienic passports of the

  19. Comparative response of dogs and monkeys to sublethal acute and continuous low dose-rate gamma-ray exposure

    International Nuclear Information System (INIS)

    Spalding, J.F.; Holland, L.M.; Johnson, O.S.; LaBauve, P.M.; London, J.E.; Prine, J.R.; Vigil, E.A.

    1977-02-01

    Monkeys (Macaca mulatta) and dogs (beagle) were given thirteen 100-rad gamma-ray doses at 28-day intervals. The comparative response (injury and recovery) of the hematopoietic system of the two species was observed at 7-day intervals during the exposure regime. At 84 days after the thirteenth gamma-ray dose, the 1300-rad conditioned and control dogs and monkeys were challenged continuously with 35 R/day until death to determine the amount of radiation-induced injury remaining in conditioned animals as a reduction in mean survival time. Dogs (50 percent) and monkeys (8 percent) died from injury incurred during the conditioning exposures. Thus, the comparative response of dogs and monkeys to dose protraction by acute dose fractionation was similar to what might be expected from a single acute dose. Mean survival times for nonconditioned dogs and monkeys during continuous exposure at 35 R/day were the same (approximately 1400 h). Thus, hematopoietic response of the two species by this method of dose protraction was not significantly different. Mean survival times of conditioned dogs and monkeys during the continuous 35 R/day gamma-ray challenge exposure were greater than for their control counterparts. Thus, the long-term radiation-induced injury was not measurable by this method. Conditioning doses of more than four times the acute LD 50 - 30 in dogs and approximately two times that of monkeys served only to increase both mean survival time and variance in a gamma-ray stress environment with a dose rate of 35 R/day

  20. X-ray exposures given with various combinations of film and screen

    International Nuclear Information System (INIS)

    Schlenker, R.A.; Kirsh, I.E.

    A comparison of entrance exposure doses of patients for various film and screen combinations and xeroradiographs showed that moderate speed screen and film gave exposures 4 to 7 times greater than fast film and screen and that xeroradiographs produced exposures 20 to 40 times greater than fast film and screen. Xeroradiographs produced table top incident exposures which exceeded Illinois Department of Health limits, while conventional film-screen combinations did not. (U.S.)

  1. Radiometric dating and quantitative analysis of elements in depth profiles of sediments by means of nuclear physical as well as X-ray fluorescence and atomic emission spectroscopic methods

    International Nuclear Information System (INIS)

    Schoenburg, M.

    1987-01-01

    The measurement of heavy metal concentration in sediments is of great importance for the assessment of water quality. If dating of the different layers of sediment cores is possible, informations about the history of pollution can be inferred. This paper describes the development and practical test of a procedure suitable for the investigation of sediment cores. Both the element analysis and the dating are based on physical methods. For element concentration determination inductively coupled plasma atomic emission spectrometry (ICP), total-reflection X-ray fluorescence analysis (TXRF) and neutron activation analysis (NAA) are used. The techniques are described and compared. For dating radiometric measurements of 210 Pb and 137 Cs are carried out with a coaxial well-type germanium γ-ray detector in a special low-level arrangement. Results of the systematic investigations are presented and a few individual depth profiles are discussed. (orig.) With 34 figs., 20 tabs [de

  2. A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Burion, Steve; Funk, Tobias; Speidel, Michael A.

    2013-01-01

    Purpose: Reduction of radiation dose in x-ray imaging has been recognized as a high priority in the medical community. Here the authors show that a regional adaptive exposure method can reduce dose-area product (DAP) in x-ray fluoroscopy. The authors' method is particularly geared toward providing dose savings for the pediatric population. Methods: The scanning beam digital x-ray system uses a large-area x-ray source with 8000 focal spots in combination with a small photon-counting detector. An imaging frame is obtained by acquiring and reconstructing up to 8000 detector images, each viewing only a small portion of the patient. Regional adaptive exposure was implemented by varying the exposure of the detector images depending on the local opacity of the object. A family of phantoms ranging in size from infant to obese adult was imaged in anteroposterior view with and without adaptive exposure. The DAP delivered to each phantom was measured in each case, and noise performance was compared by generating noise arrays to represent regional noise in the images. These noise arrays were generated by dividing the image into regions of about 6 mm 2 , calculating the relative noise in each region, and placing the relative noise value of each region in a one-dimensional array (noise array) sorted from highest to lowest. Dose-area product savings were calculated as the difference between the ratio of DAP with adaptive exposure to DAP without adaptive exposure. The authors modified this value by a correction factor that matches the noise arrays where relative noise is the highest to report a final dose-area product savings. Results: The average dose-area product saving across the phantom family was (42 ± 8)% with the highest dose-area product saving in the child-sized phantom (50%) and the lowest in the phantom mimicking an obese adult (23%). Conclusions: Phantom measurements indicate that a regional adaptive exposure method can produce large DAP savings without compromising

  3. Irradiation of dates

    International Nuclear Information System (INIS)

    Farkas, J.; Al-Charchafchy, F.; Al-Shaikhaly, M.H.; Mirjan, J.; Auda, H.

    1974-01-01

    Testing of the technical feasibility of radurization of fresh dates was attempted. In addition preliminary studies were carried out to investigate the applicability of gamma rays to date syrup manufacture. The varieties Zahdi, Lelwi and Tabarzel were studied at different stages of ripening. The eating quality of fresh dates was not affected significantly by irradiation even with doses of 270 and 540 krad. The duration of the softening process, after-ripening, of dates was prolonged by low doses of 10-30 krad in the majority of the experimental batches. The time period of after-ripening was reduced with 270 krad, as well as with 540 krad as a result of shortening of the induction period, i.e. the time after which the date begins to soften. The microbial spoilage of khalaal Lelwi dates was considerably reduced by irradiation with doses above 90 krad. The dibis yield of fully rutab dates was highly increased by the radiation doses of 375 to 2000 krad. The darkness and viable cell count of dibis pressed from irradiated dates were significantly lower than that of untreated dates. (F.J.)

  4. Development of a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value

    International Nuclear Information System (INIS)

    Kueppers, C.; Sering, M.; Poppe, B.; Poplawski, A.; Looe, H.K.; Beyer, D.; Pfaffenberger, A.; Chofor, N.; Eenboom, F.

    2012-01-01

    The research project on the development a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value includes the following issues: Fundamental facts: dental X-ray examination techniques, dose relevant factors and characteristics during X-ray examinations, radiation exposed organs during dental X-ray examinations, dose assessment based on phantoms. Materials and methodologies of the project: TLD measurements using the phantom, calculation of the effective dose during dental X-ray examinations, properties and settings of the reference facilities for the determination of radiation exposure, selection of dental offices, dosimetric measurements, data acquisition and statistical evaluation. Results of dosimetric examinations: results of dosimetric measurements at reference facilities, results of dosimetric measurements in dental offices. Discussion of the concept for the determination of the radiation exposure during dental X-ray examinations.

  5. Determination of energy absorbed during X-ray exposure of the forearm by means of thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Hofmann, E.

    1982-01-01

    LiF dose meters were used to determine radiation doses in conventional X-ray diagnostic pictures of the forearm. The paper describes a method for determining integral doses by using these dose meters. It describes in detail how a phantom forearm apt for the purpose is to be made. In the Federal Republic of Germany, malignant growth incidence due to X-ray pictures of the forearm is enhanced by about .01 cases each year. The malignant growth incidence rate caused by X-ray diagnostic measures is low. It is therefore generally justified to neglect limbs in exemplary studies of radiation exposure. All calculations and considerations took into account that all possible radiation protection measures have been duly applied. (orig./DG) [de

  6. Solar proton exposure of an ICRU sphere within a complex structure part II: Ray-trace geometry.

    Science.gov (United States)

    Slaba, Tony C; Wilson, John W; Badavi, Francis F; Reddell, Brandon D; Bahadori, Amir A

    2016-06-01

    A computationally efficient 3DHZETRN code with enhanced neutron and light ion (Z ≤ 2) propagation was recently developed for complex, inhomogeneous shield geometry described by combinatorial objects. Comparisons were made between 3DHZETRN results and Monte Carlo (MC) simulations at locations within the combinatorial geometry, and it was shown that 3DHZETRN agrees with the MC codes to the extent they agree with each other. In the present report, the 3DHZETRN code is extended to enable analysis in ray-trace geometry. This latest extension enables the code to be used within current engineering design practices utilizing fully detailed vehicle and habitat geometries. Through convergence testing, it is shown that fidelity in an actual shield geometry can be maintained in the discrete ray-trace description by systematically increasing the number of discrete rays used. It is also shown that this fidelity is carried into transport procedures and resulting exposure quantities without sacrificing computational efficiency. Published by Elsevier Ltd.

  7. Relationship between X-ray exposure and malignant transformation in C3H 10T1/2 cells

    International Nuclear Information System (INIS)

    Kennedy, A.R.; Fox, M.; Murphy, G.; Little, J.B.

    1980-01-01

    The appearance of transformed foci after x-irradiation of the C3H 10T1/2 line of murine cells requires extensive proliferation followed by prolonged incubation under conditions of confluence. When the progeny of irradiated cells are resuspended and plated to determine the number of potential transformed foci, the absolute yield is constant over a wide range of dilutions and is similar to that observed in cultures that have not been resuspended. In addition, for cells exposed to a given x-ray dose, the number of transformed foci per dish is independent of the number of irradiated cells. These observations suggest that few, if any, of the transformed clones occur as a direct consequence of the x-ray exposure and challenge the hypothesis that transformed foci are the clonal products of occasional cells that have experienced an x-ray-induced mutational change. Rather, it appears that at least two steps are involved. We suggest that exposure to x-rays results in a change, for example, the induction or expression of some cell function, in many or all of the cells and that this change is transmitted to the progeny of the surviving cells; a consequence of this change is an enhanced probability of the occurrence of a second step, transformation, when these cells are maintained under conditions of confluence

  8. The rate of X-ray-induced DNA double-strand break repair in the embryonic mouse brain is unaffected by exposure to 50 Hz magnetic fields.

    Science.gov (United States)

    Woodbine, Lisa; Haines, Jackie; Coster, Margaret; Barazzuol, Lara; Ainsbury, Elizabeth; Sienkiewicz, Zenon; Jeggo, Penny

    2015-06-01

    Following in utero exposure to low dose radiation (10-200 mGy), we recently observed a linear induction of DNA double-strand breaks (DSB) and activation of apoptosis in the embryonic neuronal stem/progenitor cell compartment. No significant induction of DSB or apoptosis was observed following exposure to magnetic fields (MF). In the present study, we exploited this in vivo system to examine whether exposure to MF before and after exposure to 100 mGy X-rays impacts upon DSB repair rates. 53BP1 foci were quantified following combined exposure to radiation and MF in the embryonic neuronal stem/progenitor cell compartment. Embryos were exposed in utero to 50 Hz MF at 300 μT for 3 h before and up to 9 h after exposure to 100 mGy X-rays. Controls included embryos exposed to MF or X-rays alone plus sham exposures. Exposure to MF before and after 100 mGy X-rays did not impact upon the rate of DSB repair in the embryonic neuronal stem cell compartment compared to repair rates following radiation exposure alone. We conclude that in this sensitive system MF do not exert any significant level of DNA damage and do not impede the repair of X-ray induced damage.

  9. On the radiation exposure dose and health management history during 50 years of x-ray working

    International Nuclear Information System (INIS)

    Yoshida, Tomihiro

    1981-01-01

    My X-ray working history has become 50 years at the end of April, 1980. At this chance, the following data were summarized; the case numbers of X-ray photographs (517,132 cases), total amounts of radiation exposure dose (66.85 roentgen) and the results of blood test, which were experienced during past 50 years. The amounts of exposure dose during 35 years till 1965 were measured using my own method, which measured the film blackening as 30 milli-roentgen per week by certain standard method. After 1966 till 1980, the exposure dose were recorded using that of the film-badge service of Nippon Hoan Yohin Kyokai. The total amounts of exposure dose during 50 years were about 1/4 of D = 5 (N - 18). The results of blood test during last 27 years were found to be normal values. Then, it is happy to say that my body has been protected completely, from radiation hazard as a result of taking radiation protection and checking blood test always at my daily radiation works. The data of my own experiences during 50 years are summarized and reported in this paper. (author)

  10. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  11. Radiation exposure and image quality in X-ray diagnostic radiology. Physical principles and clinical applications. 2. ed.

    International Nuclear Information System (INIS)

    Saebel, Manfred; Aichinger, Horst; Dierker, Joachim; Joite-Barfuss, Sigrid

    2012-01-01

    Diagnostic X-rays are the largest contributor to radiation exposure to the general population, and protecting the patient from radiation damage is a major aim of modern health policy. Once the decision has been taken to use ionising radiation for imaging in a particular patient, it is necessary to optimize the image acquisition process taking into account the diagnostic quality of the images and the radiation dose to the patient. Both image quality and radiation dose are affected by a number of parameters, knowledge of which permits scientifically based decision making. The authors of this second edition of Radiation Exposure and Image Quality in X-ray Diagnostic Radiology have spent many years studying the optimization of radiological imaging. In this book they present in detail the basic physical principles of diagnostic radiology and their application to clinical problems. Particular attention is devoted to evaluation of the dose to the patient, the influence of scattered radiation on image quality, the use of antiscatter grids, and optimization of image quality and dose. The final section is a supplement containing tables of data and graphical depictions of X-ray spectra, interaction coefficients, characteristics of X-ray beams, and other aspects relevant to patient dose calculations. In addition, a complementary CD-ROM contains a user-friendly Excel file database covering these aspects that can be used in the reader's own programs. Since the first edition, the text, figures, tables, and references have all been thoroughly updated, and more detailed attention is now paid to image quality and radiation exposure when using digital imaging and computed tomography. This book will be an invaluable aid to medical physicists when performing calculations relating to patient dose and image quality, and will also prove useful for diagnostic radiologists and engineers. (orig.)

  12. New constraints on slip rates of the Fodongmiao-Hongyazi fault in the Northern Qilian Shan, NE Tibet, from the 10Be exposure dating of offset terraces

    Science.gov (United States)

    Yang, Haibo; Yang, Xiaoping; Huang, Xiongnan; Li, An; Huang, Weiliang; Zhang, Ling

    2018-01-01

    The Fodongmo-Hongyazi fault (FHF) is a major thrust of Northeastern Tibet, bounding the Qilian Shan. It accommodates crustal shortening across this region and has produced a strong historical earthquake. Until now the slip rate has been poorly constrained, limiting our understanding of its role in the accommodation of deformation across this region. In this paper, faulted terraces at two sites on the western and middle segments of the FHF were mapped with satellite imagery and field observations. Chronological constraints are placed on the ages of displaced river terraces at these sites using terrestrial cosmogenic nuclide (TCN) exposure dating. These ages combined with offsets measured from SPOT 6 DEM's yield average vertical slip rates of 1.3 ± 0.1 mm/yr for the western segment since ∼207 ka and 0.9 ± 0.1 mm/yr since ∼46 ka for the middle segment. These data suggest that the FHF accommodates ∼15-20% of the total shortening across the Qilian Shan (5.5-7 mm/yr). In addition, comparisons of our data with published slip rates along the Northern Qilian Thrust Fault Zone show that the fastest tectonic uplift occurs along the western portion of the Northern Qilian Shan. This is consistent with estimates deduced from geomorphology. The western portion of the Qilian Shan is mainly controlled by compressional deformation produced by the northward movement of the Northeastern Tibetan Plateau, while the eastern Qilian Shan is mainly controlled by the eastward extrusion of material along the left-lateral Haiyuan strike-slip Fault.

  13. Aberrant cell divisions in root meristeme of maize following exposure to X-rays low doses compared to similar effects of 50 Hz electromagnetic exposure

    Directory of Open Access Journals (Sweden)

    Luchian T.

    2012-04-01

    Full Text Available The response of maize to radiation exposure was investigated by two cytogenetic methods considering the importance of the geno-toxic effect for environmental and agricultural purposes. Uniform genophond seeds, freshly germinated, were exposed to relatively low radiation doses using a radiotherapy X-ray applicator from a hospital irradiation device and to a 50 Hz electromagnetic field with about 10 mT magnetic induction (generated within laboratory assembled electromagnetic coils. Radicular meristeme tissue aliquots were prevailed for cytogenetic investigation based on microscopic observations and cell counting. Microscope slides were prepared following a specific procedure (squash technique and Feulgen method based on modified Carr reactive coloration. Mitotic index as well as chromosomal aberration percentage were calculated for more than 30,000 cells taken into account. From a qualitative viewpoint, chromosomal aberrations such as interchromatidian bridges, lagging and expelled chromosomes and multipolar divisions were evidenced - no distinct situation for either ionizing radiation or electromagnetic field being identified. The main quantitative difference consisted in the increased mitotic index for electromagnetic exposure increased times compared with the diminished mitotic index in the case of low X-ray doses.

  14. Exposure assessment of neonates in israel to x-ray radiation during hospitalization at neonatal intensive care unit

    International Nuclear Information System (INIS)

    Datz, H.

    2005-03-01

    Nowadays nearly 10% of all births in western countries are premature. In the last decade, there has been an increase of 45% in the number of neonates that were born in Israel. At the same time, the survival of neonates, especially those with very low birth weight, VLBW, (less than 1,500 gr), has increased dramatically. Diagnostic radiology plays an important role in the assessment and treatment of neonates requiring intensive care. During their prolonged and complex hospitalization, these infants are exposed to multiple radiographic examinations involving X-ray radiation. The extent of the examinations that the infant undergoes depends on its birth weight, gestational age and its medical problems, where most of the treatment effort is focused especially on VLBW neonates. Most of the diagnostic X-ray examinations taken during the hospitalization of neonates in the neonatal intensive care unit (NICU) consist of imaging of the respiratory and gastrointestinal systems, namely, the chest and abdomen. The imaging process is done using mobile X-ray units located at the NICUs. Due to their long hospitalization periods and complex medical condition, all neonates, and neonates with VLBW in particular, are exposed to a much higher level of diagnostic radiation, compared to normal newborns. The goal of this research was to assess the extent of the exposure of neonates in Israel to X-ray radiation during their hospitalization at the neonatal intensive care unit. Five NICUs, located at different geographical zones in Israel and treating 20% of all newborns in Israel every year, participated in this research. The research was conducted in three phases: Phase I: Collection of information on radiographic techniques and exposure parameters (e.g. kV, mAs, focus to skin distance (FSD), examination borders). 499 X-ray examinations (from 157 neonates) were evaluated for necessary and unnecessary exposure of the neonate's organs to X-ray radiation during these examinations. Phase II

  15. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  16. X-ray diagnostic study on the optimization of digital radiography in dentistry. Optimal exposure conditions for X-ray CCD sensor

    International Nuclear Information System (INIS)

    Hakata, Toshifumi

    2002-01-01

    The purpose of this research is to reduce the patient dose by optimization of irradiation conditions of an X-ray CCD sensor in intra-oral digital radiography. The X-ray diagnosis was divided into two, high quality-of-image diagnosis and low quality-of-image diagnosis, and it optimized by using the exposure of necessary minimum for each. The image quality of CCD was evaluated using the signal-to-noise ratio (SNR) in order to estimate the influence of irradiation conditions. The dose based on CCD maker setting value was set up so that the highest quality of image might be obtained mostly. In low quality-of-image diagnosis, even if it reduced the dose to 13.2% of standard irradiation, SNR was 40% and interpretation was possible. In high quality-of-image diagnosis, even if it reduces the dose to 49% of standard irradiation, SNR remained 80% and there were few differences of the image with a standard. A study of the digital X-ray examination taken at the dental clinic showed high quality-of-image diagnosis was 69% and low quality-of-image one was 31%. When this optimization was performed, it was presumed that reduction of about 62% of the dose is possible. (author)

  17. Evaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulation

    International Nuclear Information System (INIS)

    Santos, Felipe A.; Galeano, Diego C.; Santos, William S.; Carvalho Júnior, Albérico B.

    2016-01-01

    In this work irradiation scenarios that simulated chest and abdomen examinations involving mobile X-ray equipment in hospitals were modeled with the purpose of calculating conversion coefficient for effective dose (CC E ), normalized to entrance surface dose (ESD), applied to patients and public individuals. These coefficients can easily be used in this practice. Patients and public individuals were represented by a pair of anthropomorphic phantoms inserted in the MCNPX 2.7.0 radiation transport code. One of the phantoms (patient) was irradiated with the direct beam simulating examinations of the chest and abdomen, each with two fields of irradiation, ideal (IF) and extrapolated (EF). Using the software SPECGEN X-ray spectra from 60 to 100 kVp at 10 kVp intervals were generated and used in this work. The other phantom (public individual) was positioned 50–200 cm from the patient. In relation to the CC E calculated in the patient, the average increase obtained between the irradiation fields was 62.4% for the chest examinations, and for the same conditions the CC E was calculated for abdomen examinations and found to be 8.0%. Increasing the distance between public individual and patient, reductions of up to 81.7% in the CC E in abdomen examinations and 83.4% in chest examinations were observed. Through the assessment of CC E of these scenarios, it is possible to measure the damages relating to this practice for both patients and public individuals. - Highlights: • A computational scenario involving mobile X-ray equipment in hospitals were modeled. • Evaluation of medical exposure and exposure by the public was made by CC E (E/ESD). • A pair of the anthropomorphic simulators was inserted into the input file MCNPX. • Analyze the influence in CC E for the different types of fields used in examinations. • Monitoring the reduction of CC E 's with increasing distance between the beds.

  18. Last Glacial Maximum and Lateglacial in the Polish High Tatra Mountains - Revised deglaciation chronology based on the 10Be exposure age dating

    Science.gov (United States)

    Makos, Michał; Rinterknecht, Vincent; Braucher, Régis; Tołoczko-Pasek, Anna; Arnold, Maurice; Aumaître, Georges; Bourlès, Didier; Keddadouche, Karim; Aster Team

    2018-05-01

    Deglaciation chronology of the Polish High Tatra Mountains has been reconstructed based on 10Be exposure age dating. Fifty-seven rock samples were collected from boulders located on the terminal and lateral moraines that limit the horizontal extent of the LGM and the Lateglacial glaciers in the Biała Woda and Sucha Woda catchments. The uncertainty-weighted mean age of 21.5 ± 2.5 ka obtained for the maximum terminal moraine in the Sucha Woda Valley indicates that the oldest preserved moraines were formed during the global LGM. The age population ranges between 15.1 ± 1.0 and 28.3 ± 2.0 ka, and suggests that glaciers reached their maximum position (LGM I) as early as 28-25 ka and the final stabilization of the form occurred much later possibly after melting of buried dead ice. The younger glacial oscillation (LGM II) occurred no later than 20.5 ka and is represented by well-preserved termino-lateral moraine systems in the Pańszczyca Valley. The first Lateglacial stage (LG1) in the study area is documented in the Rybi Potok Valley at the RP1 moraine (1300 m a.s.l.), which was stable at around 16.6 ± 0.3 ka. The younger LG2 stage has no defined absolute age, however, it is constrained between 16.5 and 15.5 ka by the timing of the LG3 stage. This cold event is represented by well-formed moraines in the Roztoka/Pięć Stawów Polskich, Rybi Potok and Pańszczyca valleys of which exposure age indicates their deposition between 15.0 ± 0.5 and 15.6 ± 0.1 ka. The LG1, LG2 and LG3 stages likely occurred during the Oldest Dryas cold stage (Greenland Stadial 2.1a) related to the North Atlantic cooling Heinrich Event 1. The youngest glacial oscillation is evidenced by moraines in the Pusta and Pańszczyca valleys. These moraines are composed of very large granitic blocks of which exposure ages often exhibit isotope inheritance. This is reflected by the youngest P3 moraine in the Pańszczyca Valley with a mean age of deposition close to the LGM. The R4 moraine system in

  19. Trends in x-ray photography and patient exposure dose. Questionnaire survey results compared with those in 1973. [questionnaire survey in 1979

    Energy Technology Data Exchange (ETDEWEB)

    Orito, T; Sanada, S; Maekawa, R; Koshida, K; Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine

    1980-04-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired.

  20. The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

    Directory of Open Access Journals (Sweden)

    Mehrdad Gholami

    2015-07-01

    Full Text Available Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation dose. Materials and Methods This cross-sectional study was performed on seven stationary X-ray units in sixhospitals of Lorestan province. The measurements were performed, using a factory-calibrated Barracuda dosimeter (model: SE-43137. Results According to the results, the highest output was obtained in A Hospital (M1 device, ranging from 107×10-3 to 147×10-3 mGy/mAs. The evaluation of tube voltage accuracy showed a deviation from the standard value, which ranged between 0.81% (M1 device and 17.94% (M2 device at A Hospital. The deviation ranges at other hospitals were as follows: 0.30-27.52% in B Hospital (the highest in this study, 8.11-20.34% in C Hospital, 1.68-2.58% in D Hospital, 0.90-2.42% in E Hospital and 0.10-1.63% in F Hospital. The evaluation of exposure time accuracy showed that E, C, D and A (M2 device hospitals complied with the requirements (allowing a deviation of ±5%, whereas A (M1 device, F and B hospitals exceeded the permitted limit. Conclusion The results of this study showed that old X-ray equipments with poor or no maintenance are probably the main sources of reducing radiographic image quality and increasing patient radiation dose.

  1. Technical study on reduction of patient exposure in x-ray examination

    International Nuclear Information System (INIS)

    Ohtsuka, Akiyoshi

    1983-01-01

    This paper deals with the necessity, problems and technical factors on the reduction of the patient exposure, as well as the source of disagreement between doctors and radiologic technologists with respect to their psychological evaluation of the radiological image quality. (1) The patient exposure has a close relationship to the radiological image quality and is affected by many physical and psychological factors. (2) From the patient's point of view, reduction of the patient exposure without the decrease of the image quality has the same meaning as improving the image quality without the increase of the patient exposure. (3) It is known that, in the observation of the radiological image, the radiologic technologists basically attach more importance to the physical evaluation while doctors attach more importance to the psychological evaluation. (4) If doctors and radiologic technologists have more knowledge concerning the radiological imaging technology, optimization of radiographic technique, reduction of the patient exposure and improvement of the diagnostic accuracy can be expected. (author)

  2. Different gene expression of Normal lymphobloastoid cells which exposure to different dose of 60Co γ-ray

    International Nuclear Information System (INIS)

    Xiao Yao; Yang Jian; Gao Xian; Qin Yanghua; Sun Ding; Hai Ling

    2008-01-01

    Objective: To study on the gene expression of normal lymphoblastoid cells(AHH-1) which exposure to difference dose of 60 Co γ-ray, analyses the essential different biological effect.. Methods Human AHH-1 normal line was irradiated by 60 Co γ-rays. Used human cDNA microarray to develop the transcriptional levels of the genes by hybridizing the mRNA of cells 8 h after exposured in different dose and the control cells. Cluster analysis, discrimination and bolting were used to filter the effective genes of differential expression. Results The results of data analysis showed 23 genes of differential expression closely related to biological effect of 2.0 Gy radiation, 5 genes express changed only by 0.5 Gy radiation, 5 genes express apparently both in 2.0 Gy and 0.5 Gy radiation. Conclusion: The different dose γ-rays radiation-induced significant changes in gene expression, such as PAPLN, TP53INP1, PTENP1, FOS and TPR seem to be some important components of cellular radioresponse. (authors)

  3. On micro- and macrocirculatory effects of the whole body exposure to γ-rays in the rabbit

    International Nuclear Information System (INIS)

    Asano, Makishige; Ohkubo, Chiyoji; Chiba, Masashi

    1988-01-01

    Immediate and prolonged microcirculatory effects of varying single doses of the whole body exposure of γ-rays irradiation were studied by using the intravital-microscopy concurrently with macrocirculatory hematological determination in the healthy male rabbit. The intravital-microscopy applied to the subcutaneous microcirculatory system in a transparent round-table chamber, that has been installed in advance into the ear lobe, revealed that markedly increased intravascular adhesiveness of white blood cells (WBCs) and extensive stasis similar to the intravascular coagulation of red blood cells (RBCs) developed as immediate changes soon after the γ-rays irradiation regardless of difference of exposure doses such as 50, 250, 500 and 1000 R. Although these changes disappeared within 3 - 4 weeks in animals exposed to 50 R, they persisted throughout the whole experimental period of 4 weeks at higher doses of γ-rays and the extent of the persisting changes appeared to be dose-dependent. Similarly the macrocirculatory changes such as decreases in measurements of RBCs, WBCs, hematocrit values, hemoglobin concentrations, and platelet counts and increase in erythrocyte sedimentation rates were also noticed in a dose-dependent manner. (author)

  4. Measurements and analyses of cosmic-ray exposure rates perturbed by various environmental objects

    International Nuclear Information System (INIS)

    Fukaya, Mitsuharu; Minato, Susumu

    1988-01-01

    One-dimensional intensity distributions of cosmic-rays transmitted through various large structural objects were measured to examine the feasibility of 'cosmic-ray radiography'. 1) For the rectungular building, (a) the bulk density estimation by comparison of the observed distribution with the calculated one, and (b) edge detection by differential method, were found to be possible. 2) For the stairs in the subway station, the relation between the intensities and the stairs depths was able to be interpreted by a simple model. These findings indicate that it is possible to correlate transmitted cosmic-ray intensity distributions to the structure and/or the physical quantities of large structural objects. (author)

  5. The morphofunctional state of Purkin'e cells in the cerebellum of new-born rats following laser and gamma-ray exposure

    International Nuclear Information System (INIS)

    Zubkova, S.M.; Popov, V.I.

    1993-01-01

    Following of local laser (632.8 nm, 6.3. J/cm 2 ) and whole-body Gy gamma-ray exposures of new-born rats the contrast changes of morphometrical indices, RNA amount, and chromatophilia of Purkin'e cells in the cerebellum were seen. The preliminary laser exposure of new-born rat cerebellum artially increased activity of karyogene structures of the cerebellum cells which were inhibited by 6.37 Gy gamma-rays

  6. X-ray spot film device

    International Nuclear Information System (INIS)

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  7. Radiometric dating

    International Nuclear Information System (INIS)

    Das, N.R.

    2017-01-01

    Since the discovery of natural radioactivity in uranium, in the last decade of the nineteenth century, the nuclear property of radioactive decay of radionuclides at immutable rates has been effectively utilized in dating of varieties of naturally occurring geological matrices and the organisms which constantly replenish their "1"4C supply through respiration when alive on earth. During the period, applications of radiometric dating techniques have been extensively diversified and have enabled the geologists to indicate the absolute time scales of geological formations and the evolution of the solar system, the earth, meteorites, lunar rocks, etc. and the archaeologists to record the facts of history of several important events like dinosaur era, Iceman, the Shroud in Turin and many other ancient artefacts. In the development of dating methods, varieties of naturally occurring radio-isotopic systems with favorable half-lives ranging from about 10 years to over 100 billion years have been used as radiometric clocks. (author)

  8. Europium- and lithium-doped yttrium oxide nanocrystals that provide a linear emissive response with X-ray radiation exposure

    Science.gov (United States)

    Stanton, Ian N.; Belley, Matthew D.; Nguyen, Giao; Rodrigues, Anna; Li, Yifan; Kirsch, David G.; Yoshizumi, Terry T.; Therien, Michael J.

    2014-04-01

    Eu- and Li-doped yttrium oxide nanocrystals [Y2-xO3 Eux, Liy], in which Eu and Li dopant ion concentrations were systematically varied, were developed and characterized (TEM, XRD, Raman spectroscopic, UV-excited lifetime, and ICP-AES data) in order to define the most emissive compositions under specific X-ray excitation conditions. These optimized [Y2-xO3 Eux, Liy] compositions display scintillation responses that: (i) correlate linearly with incident radiation exposure at X-ray energies spanning from 40-220 kVp, and (ii) manifest no evidence of scintillation intensity saturation at the highest evaluated radiation exposures [up to 4 Roentgen per second]. For the most emissive nanoscale scintillator composition, [Y1.9O3; Eu0.1, Li0.16], excitation energies of 40, 120, and 220 kVp were chosen to probe the dependence of the integrated emission intensity upon X-ray exposure-rate in energy regimes having different mass-attenuation coefficients and where either the photoelectric or the Compton effect governs the scintillation mechanism. These experiments demonstrate for the first time for that for comparable radiation exposures, when the scintillation mechanism is governed by the photoelectric effect and a comparably larger mass-attenuation coefficient (120 kVp excitation), greater integrated emission intensities are recorded relative to excitation energies where the Compton effect regulates scintillation (220 kVp) in nanoscale [Y2-xO3 Eux] crystals. Nanoscale [Y1.9O3; Eu0.1, Li0.16] (70 +/- 20 nm) was further exploited as a detector material in a prototype fiber-optic radiation sensor. The scintillation intensity from the [Y1.9O3; Eu0.1, Li0.16]-modified, 400 μm sized optical fiber tip, recorded using a CCD-photodetector and integrated over the 605-617 nm wavelength domain, was correlated with radiation exposure using a Precision XRAD 225Cx small-animal image guided radiation therapy (IGRT) system. For both 80 and 225 kVp energies, this radiotransparent device recorded

  9. Ultrastructural changes in spermatogonia of Wistar strain rats following acute whole-body X-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hrehorovsky, M; Horak, J [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes in spermatogonia ultrastructure in rats of Wistar strain after single whole-body X-ray irradiation with 6.4 mC.kg/sup -1/, 25.8 mC.kg/sup -1/ and 51.6 mC.kg/sup -1/ respectively, were studied. Intracellular spaces were found between spermatogonia enlarged, nuclear membranes were bent, the pheripheral teritories of chromation were electronoptically denser, the morphology of nucleoli was changed, cytoplasm was vacuolised, mitochondria were damaged, the vacuolar dilatation of agranular endoplasmic reticulum was evident and electronoptically empty vacuoles near the Golgi complex occured 48 hours after single whole-body X-ray irradiation. Qualitative changes in the ultrastructure of individual types of spermatogonia after individual exposures were similar.

  10. Restoring efficiency of hemopoietic cell transplantation in a mouse lethally irradiated by a total exposure to X rays

    International Nuclear Information System (INIS)

    Doria, Gino

    1959-10-01

    This research thesis reports the study of possibility of treatments (or restoration) of a mouse which has been submitted to a lethal dose of X rays. More particularly, the author compared the restoring efficiency of bone marrow and fetal liver injected in a mouse which had been lethally irradiated by a total exposure to X rays. He also studied the functional status of the hemopoietic graft, and the emergence of the secondary disease in mice which had been as well lethally irradiated and then restored by injection of bone marrow and fetal liver. The author then addressed the influence of the induction of immune tolerance of the host with respect to the donor on the survival of a mouse lethally irradiated and restored by homologue bone marrow [fr

  11. Protocol for X-ray dosimetry and exposure arrangements employed in studies of late somatic effects in mammals

    International Nuclear Information System (INIS)

    Zoetelief, J.; Kogel, A.J. van der; Broerse, J.J.; Scarpa, G.; Dixon-Brown, A.

    1985-01-01

    A number of European laboratories studying the late effects of ionizing radiation in animals have established an effective cooperation within the European Late Effects Project Group (EULEP) since 1970. To facilitate the exchange of biological results several techniques, including quality control of the experimental animals, pathology and dosimetry, have to be standardized. The most important aspects of the procedures for X-irradiation and dosimetry of small animals are summarized. These include recommendations on irradiation conditions, dosimetry methods, characteristics of phantoms and factors affecting X-ray dosimetry. X-irradiation procedures employed by the participating institutes are described and the results of five X-ray dosimetry intercomparisons are reported. The introduction of a common dosimetry protocol has resulted in improvements in exposure arrangements and absolute dosimetry. (author)

  12. Development of a head simulator for exposure dose estimation on patients exposed by odontological X-rays

    International Nuclear Information System (INIS)

    Moura Neto, Francisco N.; Batista, Eutropio V.; Santos, Adriano M.

    2009-01-01

    In the obtaining a odontological radiography, the individual is exposed to te radiation and part of that radiation will be absorbed by his organism. The estimative of absorbed dose can be accomplished through calculations where are considered: the distance from the source to the individual, the energy of the emitted X-ray at the moment of the exposure and the bode region exposed; and as that option does not possess great precision, alternative forms are seek for the quantification such doses. This work proposes the construction of a head simulator to be used in the estimative of absorbed dose in patients, during the accomplishment of the odontological radiographic examinations. As a perspective of work, it is intended to use the phantom to help in the absorbed doses for obtainment of parameters in X-ray odontological devices, contributing of image obtainment with more quality and less radiation dose in the patient

  13. SU-E-I-52: Effect of Various X-Ray Beam Qualities On the Exposure Index

    International Nuclear Information System (INIS)

    Yasumatsu, S; Iwase, K; Shimizu, Y; Tanaka, N; Morishita, J

    2015-01-01

    Purpose: The exposure index (EI) proposed by the International Electrotechnical Commission (IEC) 62494-1 is expected to be utilized as a standard dose index by every manufacturer. The IEC recommended the usage of RQA5 for the EI. However, X-ray beam qualities, particularly in clinical practices, vary depending on the examination objects and exposure conditions, including usage of anti-scatter grids. We investigated the effects of the X-ray beam qualities other than RQA5 on the EI. Methods: The Xray beam qualities of RQA3, 5, 7, and 9 in IEC 61267 Ed. 1.0 were adopted in a computed radiography system. A uniform exposure without objects was performed to measure the exposure indicators (S values) and air kerma (K). The relational equations between the S values and K were derived for the determination of the EI values. The EI values for RQA3, 7, and 9 were compared to those for RQA5 at the fixed S values of 100, 200, 400, and 600. Finally, the half-value layers (HVLs) using four grids (ratio 6:1, 8:1, 10:1, and 12:1) for the RQA5 X-ray were compared to those with RQA3–9. Results: The EI values for RQA3, 7, and 9 were up to 35.3%, 11.8%, and 38.7% higher, respectively, than that for RQA5 at the S value of 600. The HVLs without grids and with various grids for RQA5 were 6.85 mm Al. and in the range of 6.94–7.29 mm Al. (ΔHVL: up to 0.44 mm Al.), respectively. This variation in the HVLs with grids was smaller than that observed for RQA3–9 (ΔHVL: 2.0–7.5 mm Al.). Conclusion: Although the usage of grids may not greatly affect the EI, the X-ray beam quality for the determination of the EI cannot be ignored in the clinical evaluation of the dose index

  14. X-ray equipment for dental diagnostics with a dose-rate controller influencing the exposure voltage

    International Nuclear Information System (INIS)

    Franke, K.

    1980-01-01

    If a synoptic picture is taken of teeth or jaw the X-ray tube and the film carrier with the film and a radiation detector are moving around the patient's head. The detector signal is connected to the input of the actual value of the dose-rate controller containing a scanning and stop circuit with a storing time roughly corresponding to the exposure of three teeth. After the shot the actual value of the dose rate is adjusted to the desired value, thus a constant quality of the following pictures being achieved. (RW) [de

  15. Effective energies and exposure determinations of two different energy X-ray beams incident on a personnel monitor

    International Nuclear Information System (INIS)

    Okuno, E.; Cruz, M.T. da

    1984-01-01

    The effective energy of one X or gamma ray beam can be determined by means of two thermoluminescent (TL) dosemeters mounted between suitable filters. However, it has been observed that personnel monitors exposed to two different energy ionizing radiations provide different effective energies depeding on the type of TL phosphor used. This fact could be a powerful tool for identifying exposures to radiation with quite different effective energies which are very common in practice. Two types of TL dosemeters were used : pellets of cold pressed natural fluoride and NaCl developed in our own laboratory, and LiF, TLD-100 from Harshaw Chemical Co.. Experimental results obtained with these combined dosemeters after irradiation with different sets of exposures and energy values of ionizing radiations are also presented. (Author) [pt

  16. Effect of in utero exposure to diagnostic doses of X-rays on the growth and behaviour of mouse

    International Nuclear Information System (INIS)

    Prakash Hande, M.; Uma Devi, P.

    1992-01-01

    Intrauterine development, particularly the period of organogenesis is an especially radiosensitive phase in mammals. Teratogenic effect of low dose irradiation has been demonstrated in laboratory animals. Several studies have indicated the vulnerability of the developing human brain to radiation injury and demonstrated changes in postnatal behaviour following intrauterine animal irradiation. However, data are lacking on the comparative response of the different stages of prenatal development to low doses at levels that could result from diagnostic radiation exposure. This study attempts to empirically evaluate the differential response of critical stages in prenatal development of mouse to single low dose exposures to diagnostic X-rays. Data on growth and behaviour are briefly presented. (author). 22 refs., 2 figs., 1 tab

  17. Measurement of the exposure rate due to low energy x-rays emitted from video display terminals

    International Nuclear Information System (INIS)

    Campos, L.L.

    1988-01-01

    Thermoluminescent dosimeters of CaSO 4 :Dy have been used to measure the low energy x-rays emitted from Video Display Terminals (VDTs). For each terminal, three points were measured with five dosimeters at each point. The points were at distances of 5 and 50 cm in front of the screen and at 65 cm with an angle of approximately 50 0 . The last two positions approximate to positions of the lenses of the eye and the gonads respectively. A survey of 50 VDTs at a distance of 5 cm from the screen resulted in exposure rates nearly fifteen times below the exposure rate of 0.5 mR h -1 (0.129 μC kg -1 h -1 ) which is the limit recommended by the International Atomic Energy Agency (IAEA), Safety Series No. 9 (1967) Basic Safety Standards for Radiation Protection. (author)

  18. Exposure to ionizing radiation during dental X-rays is not associated with risk of developing meningioma: a meta-analysis based on seven case-control studies.

    Science.gov (United States)

    Xu, Ping; Luo, Hong; Huang, Guang-Lei; Yin, Xin-Hai; Luo, Si-Yang; Song, Ju-Kun

    2015-01-01

    Many observational studies have found that exposure to dental X-rays is associated with the risk of development of meningioma. However, these findings are inconsistent. We conducted a meta-analysis to assess the relationship between exposure to dental X-rays and the risk of development of meningioma. The PubMed and EMBASE databases were searched to identify eligible studies. Summary odds ratio (OR) estimates and 95% confidence intervals (95% CIs) were used to compute the risk of meningioma development according to heterogeneity. Subgroup and sensitivity analyses were performed to further explore the potential heterogeneity. Finally, publication bias was assessed. Seven case-control studies involving 6,174 patients and 19,459 controls were included in the meta-analysis. Neither exposure to dental X-rays nor performance of full-mouth panorex X-rays was associated with an increased risk of development of meningioma (overall: OR, 0.97; 95% CI, 0.70-1.32; dental X-rays: OR, 1.05; 95% CI, 0.89-1.25; panorex X-rays: OR, 1.01; 95% CI, 0.76-1.34). However, exposure to bitewing X-rays was associated with a slightly increased risk of development of meningioma (OR, 1.73; 95% CI, 1.28-2.34). Similar results were obtained in the subgroup and sensitivity analyses. Little evidence of publication bias was observed. Based on the currently limited data, there is no association between exposure to dental X-rays and the risk of development of meningioma. However, these results should be cautiously interpreted because of the heterogeneity among studies. Additional large, high-quality clinical trials are needed to evaluate the association between exposure to dental X-rays and the risk of development of meningioma.

  19. Exposure to ionizing radiation during dental X-rays is not associated with risk of developing meningioma: a meta-analysis based on seven case-control studies.

    Directory of Open Access Journals (Sweden)

    Ping Xu

    Full Text Available Many observational studies have found that exposure to dental X-rays is associated with the risk of development of meningioma. However, these findings are inconsistent. We conducted a meta-analysis to assess the relationship between exposure to dental X-rays and the risk of development of meningioma.The PubMed and EMBASE databases were searched to identify eligible studies. Summary odds ratio (OR estimates and 95% confidence intervals (95% CIs were used to compute the risk of meningioma development according to heterogeneity. Subgroup and sensitivity analyses were performed to further explore the potential heterogeneity. Finally, publication bias was assessed.Seven case-control studies involving 6,174 patients and 19,459 controls were included in the meta-analysis. Neither exposure to dental X-rays nor performance of full-mouth panorex X-rays was associated with an increased risk of development of meningioma (overall: OR, 0.97; 95% CI, 0.70-1.32; dental X-rays: OR, 1.05; 95% CI, 0.89-1.25; panorex X-rays: OR, 1.01; 95% CI, 0.76-1.34. However, exposure to bitewing X-rays was associated with a slightly increased risk of development of meningioma (OR, 1.73; 95% CI, 1.28-2.34. Similar results were obtained in the subgroup and sensitivity analyses. Little evidence of publication bias was observed.Based on the currently limited data, there is no association between exposure to dental X-rays and the risk of development of meningioma. However, these results should be cautiously interpreted because of the heterogeneity among studies. Additional large, high-quality clinical trials are needed to evaluate the association between exposure to dental X-rays and the risk of development of meningioma.

  20. γ-ray induced chromosome aberration in rabbit peripheral blood lymphocytes irradiated in partial and whole body and decline of aberration rate with time post-exposure

    International Nuclear Information System (INIS)

    Zhang Lianzhen; Deng Zhicheng; Wang Haiyan

    1997-01-01

    Te author presents the results of study on 60 Co γ-ray induced chromosome aberration in rabbits peripheral blood lymphocytes irradiated in partial and whole body and the aberration rate decrease with the time of post-exposure. The experiments included 5 groups, it was whole-body exposure group, partial-body exposure (abdomen and pelvic cavity) group, blood irradiation group in vitro and control group respectively. Radiation dose was 3.0 Gy delivered at rate of 0.5 Gy/min. The results show that it was no significant differences between whole body and in blood irradiation group. The chromosome aberration yield in whole body exposure group was higher than that in partial-body group and in the abdomen exposure group was higher than in that in the pelvic cavity irradiation; The chromosome aberration rate decreased with the time of post-exposure in partial and whole body by γ-ray irradiation

  1. Influence of turmeric on biochemical disorders induced by exposure to gamma- rays or chloropyrifos pesticide on rats

    International Nuclear Information System (INIS)

    Kamal El-Dein, E.M.; Ebrahim, R.M.

    2013-01-01

    Toxicity of Chloropyrifos and gamma-radiation exposure on rats were examined in the presence or absence of Turmeric (200 mg/ kg/ b.wt.). Effects chloropyrifos when administrated orally to rats at a dose 9 mg/ kg b .wt (1/ 4 LD 50) for 7 and 28 days showed increased level of malondialdehyde (MDA) concomitant with depletion in the levels of glutathion (GSH), superoxide dismutase (SOD) and catalase (CAT).gamma- radiation exposure effect on rats was examined in the presence or absence of turmeric . Exposure of rats to gamma-radiation (8 Gy) at a fractionated dose levels (2 Gy/ week for 4 weeks) exhibited an elevated level of MDA and decreased level of GSH, SOD and CAT. Administration of Turmeric to animals which were previously treated with Chloropyrifos or gamma-rays showed an amelioration response to the antioxidant regime. Treatment of rats with Chloropyrifos for 7 and 28 days or gamma- radiation induced an elevated serum transaminases level(ALT and AST),Alkaline phosphatase (ALP) and Acid phosphatase activity (ACP), creatinine concentration, blood urea and uric acid.Also treatment of rats with Chloropyrifos for 7 and 28 days or gamma-radiation induced a decline in the testosterone level associated with alteration in the levels of follicular stimulating hormone (FSH),Iuetinizing hormone (LH) and prolactin (PRL).Results observed due to Chloropyrifos pesticide or radiation-exposure have been ameliorated by turmeric administration. It could be concluded that turmeric might protect from oxidative stress

  2. Comparison of gestational dating methods and implications for exposure-outcome associations: an example with PM2.5 and preterm birth

    Science.gov (United States)

    OBJECTIVES: Estimating gestational age is usually based on date of last menstrual period (LMP) or clinical estimation (CE); both approaches introduce potential bias. Differences in methods of estimation may lead to misclassificat ion and inconsistencies in risk estimates, particu...

  3. Occupational exposure and risks associated with the X-ray and gamma ray scanners used for destination inspection at the port of Tema, Ghana

    International Nuclear Information System (INIS)

    Gbormittah, S.V.

    2010-01-01

    The x-ray linear accelerator scanner with average energy of 5 MeV operated by the Gateway Services Limited (GSL) and the Cobalt-60 gamma ray scanner with average energy of 1.25 MeV operated by the Ghana Customs Inspection Company Limited (GCIC) have been in use for destination inspection at the Port of Tema for the past ten (10) and six (6) years respectively. For radiation protection purposes, there is the need to assess the risk of exposure to ensure that Staff are not unduly overexposed to minimize the likelihood of adverse radiation effects. The prime objective of this research was to compare the risks from exposure, working conditions and safety culture of the two facilities in order to determine the facility that gives higher levels of exposure to the workers. Data was collected by means of questionnaires and measurements at the two facilities for a period of eight (8) weeks. Personal monitoring data for the occupationally exposed workers of the two facilities for a period sixty-one (61) months were obtained from the Personal Monitoring Laboratory of the Radiation Protection Board; these data were used for mean annual dose, mean annual collective dose and risks assessments for Staff of the two facilities. Ambient dose measurements were carried out with a calibrated Thermo Electron Micro Sievert Doserate survey meter and LiF TLD-100 dosimeters at selected points in the two facilities were 1.16 mSv/a and 1.41 mSv/a respectively. The mean annual effective doses estimated for the collective doses were 8.1man-Sv and 21.15 man-Sv for Staff of GSL and GCIC respectively. Assessment of risks using the ICRP 103 and 60 risk assessment models indicated that Staff of GSL and GCIC had a 0.14% and 0.17% risk of developing fatal cancer respectively. Staff of GSL had a 0.02% risk of passing on adverse hereditary traits to offsprings born after exposure while Staff of GCIC had a hereditary risk of 0.03% of passing on adverse hereditary traits to offsprings born after exposure

  4. Radiocarbon dating

    International Nuclear Information System (INIS)

    Lazos R, L.

    2005-01-01

    The application of the radiocarbon dating in archaeology has not served only to solve problems related with the establishment of chronologies, but also in the development of archaeological methods of excavation and interpretation. This has been possible because the dating method by radiocarbon provides a common temporary scale that transcends the cultural and regional frontiers. It is even spoken of the revolution that has meant the fact that the application of this method has allowed to the archaeologist to pass from the construction of chronologies until the evaluation and dynamic interpretation of the archaeological data to build theories. This work explains and compares methods for the detection of 14 C, as the gas counting, the liquid scintillation counting and the mass spectrometry with accelerators. (Author)

  5. Reducing exposure of X-ray radiodiagnosis personnel with use of apron

    International Nuclear Information System (INIS)

    Snobr, J.

    1988-01-01

    Experimental results are presented showing dose reduction in X-ray irradiation thanks to protective aprons from lead-containing rubber. The values were used to calculate a reduction in the effective dose equivalent while using the protective apron for isotropic irradiation and for frontal irradiation. A method for optimizing the lead equivalent of the protective apron is suggested. (author). 7 tabs., 6 refs

  6. X-ray exposure hazards for physicians performing ablation procedures and device implantation

    DEFF Research Database (Denmark)

    Marinskis, Germanas; Bongiorni, Maria Grazia; Dagres, Nikolaos

    2013-01-01

    The purpose of the survey was to evaluate physician's and authorities policies and clinical practices when using occupational X-ray during ablation procedures and device implantation. This survey shows infrequent use of lead gloves, radiation absorbing pads, and lead glass cabins, but increasing ...

  7. Relative biological effectiveness (RBE) of fission neutrons and gamma rays at occupational exposure levels: Volume 1, Studies on the genetic effects in mice of 60 equal once-weekly exposures to fission neutrons and gamma rays

    International Nuclear Information System (INIS)

    Grahn, D.; Carnes, B.A.

    1987-10-01

    The relative biological effectiveness (RBE) values for low doses of fission neutrons compared to 60 Co gamma rays were determined with four separate assessments of genetic damage induced in young hybrid male mice. Both radiations were delivered at low dose levels over about one-half the adult lifetime as 60 once-weekly exposures. Genetic damage assessed included both transient and residual injury. The latter is more critical, as residual genetic injury can be transmitted to subsequent generations long after the radiation exposures have ceased. Assays were performed periodically during the 60-week exposure period and at 10 or more weeks after the irradiations had terminated. RBE values, with few exceptions, ranged between 5 and 15 for transient injury and between 25 and 50 for different types of residual genetic injury. The most important form of residual genetic damage in this study was the balanced reciprocal chromosome translocation. These translocations continue to be transmitted throughout reproductive life and can lead to reduced fertility and increased prenatal mortality. The best estimate of the RBE value for translocations was 45 +- 10. Implications and recommendations with regard to the neutron quality factor will be presented conjointly with the findings from the data obtained in this same project on life shortening and on the risks of incidence or death from neoplastic disease. 64 refs., 23 tabs

  8. DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2013-01-01

    Full Text Available We introduce a system of Diagnostic Reference Levels (DRLs for patients medical exposure for national health care practice implementation. DRLs are an effective way of the patient radiation protection through the optimization of the medical exposure. The paper discusses and compares different methods of determining the DRLs based on measured and/or calculated quantities of patient’s dose: dose area product (DAP, entrance surface dose (ESD and an effective dose. Distributions of different dose quantities in different Saint-Petersburg clinics are shown on the example of chest PA examinations. The results are compared with the data from other sources. Regional DRLs for Saint-Petersburg are proposed.

  9. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo; Kamei, Tetsuya; Koga, Sukehiko

    1998-01-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  10. Studies on the radiation exposure and protection at the X-ray radiography in the medical care at home

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shoichi; Fujii, Shigehisa; Asada, Yasuo; Orito, Takeo [Fujita Health Univ., Toyoake, Aichi (Japan). School of Health Science; Kamei, Tetsuya; Koga, Sukehiko

    1998-12-01

    Since there are scarce studies on the exposure and protection at the radiography in the medical care at home, authors performed such studies as comparison of doses from self-rectifying and inverter tubes, exposure and protection to patients and nursing persons and actual measurement (October, 1997) at home in Tohno city, Iwate prefecture, of scattering radiation dose at radiography. Apparatuses used were: Portable X-ray equipments; self-rectifying types (Toshiba TR-20 and Medisonacoma PX 30N) and an inverter type (Medisonacoma PX-15HF), Kyoto Kagaku WAC water phantom, X-ray analyzer Model 200 of Kasei Optonics, and Dosimeters (Victoreen Radocon ionization dosimeter and Aloka ICS-301 ionization chamber survey meters). Radiation qualities, surface doses and scattering doses of the equipments under various conditions were compared by the half value layer and effective energy measured with the analyzer. Actual measurement of scattering dose was done at home for 4 patients at chest radiography. Annual dose in monthly ordinary radiography at home, when the distance was >200 cm far from the flux center, was found about 1/100 of 1 mSv (the annual public dose limit), thus securing the safety of nurses. (K.H.)

  11. Dating Techniques

    Indian Academy of Sciences (India)

    However, this can not be always true as there are other factors like nature of pigments, depth of engravings, hardness of the rock, factors of bioturbation, mineral staining, degree of exposure etc. that should be considered. Even different parts of the same drawing are weathered differently depending on the above factors, ...

  12. Study of the argyrophil structures of thymus connective tissue after exposure to X-rays

    International Nuclear Information System (INIS)

    Beletskij, V.K.; Beletskaya, L.V.; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Ehpidemiologii i Mikrobiologii)

    1980-01-01

    Studied are argyrophil structures of thymus connective tissue - histiocytes (appendiculate macrophages) and reticuline fibers after the bulk of lymphoid cells has migrated from the organ due to irradiation of animals with X-rays. 10 intact and 16 experimental guinea pigs subjected to the whole-body irradiation with X-rays in the dose of 1000-3000 rad have been used for investigations. It is shown that argyrophil stroma elements of thymus connective tissue, histiocytes and reticular cells, are rather resistant to X-rays and preserve their argyrophily property in the irradiation with high doses, as well as the epithelial cells of the organ. Paraplastic structures in irradiated animals are expressed more completely being demasked as a result of lymphocyte migration and death. The expressed hypertrophy and proliferation of reticular cells and appendiculate macrophages are probably the response to the alternative process in the organ tissues caused by irradiation. A close structural connection of reticular and epithelial tissues on the territory of both layers of thymus sections is noted

  13. Aging simulation of the tailings from Stava fluorite extraction by exposure to gamma rays

    Directory of Open Access Journals (Sweden)

    Gianluca Bella

    Full Text Available Abstract Tailings storage facilities are disposal systems for storing the waste products of the mining industry consisting of a slurry mixture made of soil, rock and water that remain after the mineral values have been removed from the patent ore. Tailings dams are supposed to last forever, so after their deposition, tailings can experience aging processes with physical and chemical changes depending on the interactions between local conditions and source mineralogy. The consequences of these aging processes are increased interlocking of particles and oxidation processes, sometimes making previously safely held contaminants available and mobile. Among the long-term aging processes, the natural ionizing radiation (from radioactive isotopes of the soils, cosmic rays, and also ultraviolet rays from the sun can be considered, as proposed in the current research. Furthermore, in many countries, tailings are beginning to be re-used as backfill, landscaping material or feedstock for cement and concrete. So if any, the long-term physical and chemical modifications could affect the hydraulic and mechanical behaviour of tailings with relevant economic consequences. For these reasons, wet and dry silty samples of tailings spilled out after the failure of the Stava tailings dam (Trentino Alto Adige, Italy were exposed to gamma rays, as an accelerated aging technique to simulate the natural ionizing radiation, and then characterized. The modifications on physical and chemical properties were observed and, despite certain chemical stability, some physical changes were observed, particularly in terms of size particle distribution, inner porosity of the particles and specific surface.

  14. Aging simulation of the tailings from Stava fluorite extraction by exposure to gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Bella, Gianluca; Barbero, Monica; Barpi, Fabrizio, E-mail: gianluca.bella@polito.it, E-mail: monica.barbero@polito.it, E-mail: fabrizio.barpi@polito.it [Politecnico di Torino - DISEG (Italy); Lameiras, Fernando Soares, E-mail: fsl@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Espósito, Terezinha de Jesus, E-mail: esposito@etg.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Transporte e Engenharia Geotécnica

    2017-10-15

    Tailings storage facilities are disposal systems for storing the waste products of the mining industry consisting of a slurry mixture made of soil, rock and water that remain after the mineral values have been removed from the patent ore. Tailings dams are supposed to last forever, so after their deposition, tailings can experience aging processes with physical and chemical changes depending on the interactions between local conditions and source mineralogy. The consequences of these aging processes are increased interlocking of particles and oxidation processes, sometimes making previously safely held contaminants available and mobile. Among the long-term aging processes, the natural ionizing radiation (from radioactive isotopes of the soils, cosmic rays, and also ultraviolet rays from the sun) can be considered, as proposed in the current research. Furthermore, in many countries, tailings are beginning to be re-used as backfill, landscaping material or feedstock for cement and concrete. So if any, the long-term physical and chemical modifications could affect the hydraulic and mechanical behaviour of tailings with relevant economic consequences. For these reasons, wet and dry silty samples of tailings spilled out after the failure of the Stava tailings dam (Trentino Alto Adige, Italy) were exposed to gamma rays, as an accelerated aging technique to simulate the natural ionizing radiation, and then characterized. The modifications on physical and chemical properties were observed and, despite certain chemical stability, some physical changes were observed, particularly in terms of size particle distribution, inner porosity of the particles and specific surface. (author)

  15. Development of an algorithm for X-ray exposures using the Panasonic UD-802A thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    McKittrick, Leo; Currivan, Lorraine; Pollard, David; Nicholls, Colyn; Romero, A.M.; Palethorpe, Jeffrey

    2008-01-01

    Full text: As part of its continuous quality improvement the Dosimetry Service of the Radiological Protection Institute of Ireland (RPII) in conjunction with Panasonic Industrial Europe (UK) has investigated further the use of the standard Panasonic algorithm for X-ray exposures using the Panasonic UD-802A TL dosemeter. Originally developed to satisfy the obsolete standard ANSI 13.11-1983, the standard Panasonic dose algorithm has undergone several revisions such as HPS N13.11-2001. This paper presents a dose algorithm that can be used to correct the dose response at low energies such as X-ray radiation using a four element TL dosemeter due to the behaviour of two different independent phosphors. A series of irradiations with a range of energies using N-20 up to Co-60 were carried out with our particular interest being in responses to X-ray irradiations. Irradiations were performed at: RRPPS, University Hospital Birmingham NHS Foundation Trust, U.K.; HPA, U.K. and CIEMAT, Madrid, Spain. Different irradiation conditions were employed which included: X-ray from narrow and wide spectra as described by ISO 4037-1 (1996), and ISO water slab phantom and PMMA slab phantom respectively. Using the UD-802A TLD and UD-854AT hanger combination, the response data from the series of irradiations was utilised to validate and if necessary, modify the photon/beta branches of the algorithm to: 1. Best estimate Hp(10) and Hp(0.07); 2. Provide information on irradiation energies; 3. Verification by performance tests. This work further advances the algorithm developed at CIEMAT whereby a best-fit, polynomial trend is used with the dose response variations between the independent phosphors. (author)

  16. ERX: a software for editing files containing X-ray spectra to be used in exposure computational models

    International Nuclear Information System (INIS)

    Cabral, Manuela O.M.; Vieira, Jose W.; Silva, Alysson G.; Leal Neto, Viriato; Oliveira, Alex C.H.; Lima, Fernando R.A.

    2011-01-01

    Exposure Computational Models (ECMs) are utilities that simulate situations in which occurs irradiation in a given environment. An ECM is composed primarily by an anthropomorphic model (phantom), and a Monte Carlo code (MC). This paper presents a tutorial of the software Espectro de Raios-X (ERX). This software performs reading and numerical and graphical analysis of text files containing diagnostic X-ray spectra for use in algorithms of radioactive sources in the ECMs of a Grupo de Dosimetria Numerica. The ERX allows the user to select one among several X-ray spectrums in the energy range Diagnostic radiology X-Ray most commonly used in radiology clinics. In the current version of the ERX there are two types of input files: the contained in mspectra.dat file and the resulting of MC simulations in Geant4. The software allows the construction of charts of the Probability Density Function (PDF) and Cumulative Distribution Function (CDF) of a selected spectrum as well as the table with the values of these functions and the spectrum. In addition, the ERX allows the user to make comparative analysis between the PDF graphics of the two catalogs of spectra available, besides being can perform dosimetric evaluations with the selected spectrum. A software of this kind is an important computational tool for researchers in numerical dosimetry because of the diversity of Diagnostic radiology X-Ray machines, which implies in a mass of input data highly diverse. And because of this, the ERX provides independence to the group related to the data origin that is contained in the catalogs created, not being necessary to resort to others. (author)

  17. Implication of occupational exposure to X-Rays diagnosed during pregnancy

    International Nuclear Information System (INIS)

    Frometa Suarez, Ileana

    1998-01-01

    At the present time the risks have been described thoroughly and goods on the inherent fetus to the exhibition give sources ionizing radiations in women that are in period gestation. Presently investigation work is carried out for survey of women exposed to occupational ionizing radiations in reproductive age. The incidence is described and behavior gives these goods and its relationship with other risk factors. In this study the exposure to ionizing radiations is not revealed as main causal factor risk

  18. Cosmic-ray exposure ages of the ordinary chondrites and their significance for parent body stratigraphy

    Science.gov (United States)

    Crabb, J.; Schultz, L.

    1981-01-01

    Improved exposure ages are derived for 201 H, 203 L, and 38 LL chondrites in an effort to understand the characteristics of the chondrite parent body. The Ne-21 exposure ages were calculated from literature values taking into account shielding differences, a trapped component and radiogenic He. The exposure age distributions show clear peaks at 4.5 and 20 million years for the H chondrites, while the Ls and LLs appear more as a continuous series of intermediate peaks which may be modeled by at least six peaks between 1 and 35 million years in the case of L chondrites. The observations that every petrological type occurs in each large peak and contain solar wind gases suggest that the parent bodies have been fragmented and reassembled into a megabreccia. The H meteorites are proposed to represent the surface layer of a body with a substantial, active regolith as indicated by the relatively high abundances of solar gases. The L chondrites, on the other hand, are attributed to a parent body that was fragmented by collision about 500 million years ago.

  19. Inquiry on the radiation exposure of the Swiss population by X-ray diagnosis

    International Nuclear Information System (INIS)

    Poretti, G.G.; Bern Univ.; Jonesco-Farca, F.; Lanz, W.

    1976-01-01

    The genetic load on a population is usually expressed in terms of the so-called 'Genetically Significant Dose' (GSD), i.e. the dose which, averaged over the total population, produces the same results as the varying amounts of radiation received in reality by the individuals making up the population. It may be calculated taking into account the following parameters: 1) total number of male and female persons in the population per age group, including the foetuses, 2) average expectation of children per person, 3) number of persons having received a certain type of X-ray examination, and 4) experimental gonadal dose for this examination (for men, women and foetuses - not to be confused with the GSD). The GSD of the Swiss population for the year 1971 was calculated per age group on the basis of physicians' data on some 60,000 patients. The gonadal dose was determined experimentally in various hospitals by means of TLD dosimeters, sensitive high-pressure ionization chambers and normal chambers. The computer programme to calculate the GSD (PL/1 language) is very time-consuming, but its structure allows a new selective investigation to be made later on by merely changing the input. The results show that in Switzerland as in other countries there is a 3-4% increase per year in X-ray examinations for diagnostic purposes. The GSD for 1971 is 42-43 mrad per person in Switzerland as compared to 22 mrad for 1957. The GSD percentage is about 57% for men, about 35% for women and about 8% for foetuses. The number of X-ray examinations is almost equal for general practitioners (53.8%) and hospitals (46.2%). (orig.) [de

  20. The x-ray source application test cassette for radiation exposures at the OMEGA laser

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, K. B.; Rekow, V.; Emig, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Fisher, J. H.; Newlander, C. D. [Fifth Gait Technologies, Inc., Huntsville, Alabama 35803 (United States); Horton, R. [Gray Research, Inc., Huntsville, Alabama 35806 (United States); Davis, J. [Defense Threat Reduction Agency, Fort Belvoir, Virginia 22060 (United States)

    2012-10-15

    We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5{sup Double-Prime }) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.

  1. Level of radiation exposure to staff in X-ray diagnosis

    International Nuclear Information System (INIS)

    Zol'nikova, N.I.; Moisejtsev, P.I.; Trunov, B.V.

    1976-01-01

    In modern radiological service departments the dose rates at working placesof medical aff directly engaged in diagnostic work were found to range from 7 to 100 mR/h during fuoroscopand up to 1,200 mR/h during roentgenoscopy and ray inematography, respectively. Durig fluocopic work in the operating theatre the monthly doses to staff ranged from 100 to 380 mRfor sugeos and anaesthesists, from 110 to 225 mR for surgical nurses, and from5to 30 roranhesia nurses. AUTHOR)

  2. Variations in sensitivity of synchronized Chinese hamster cells to oxic and anoxic X-ray exposures

    International Nuclear Information System (INIS)

    Siracka, E.; Littbrand, B.; Clifton, K.H.; Revesz, L.

    1975-01-01

    V-79 Chinese hamster cells in monolayer cultures on glass surfaces were synchronized by treatment with hydroxyurea and then exposed at different times to X-rays in air or in oxygen-free argon. Survival determinations indicated that the oxygen enhancement ratio (OER) as expressed by the ratio of the respective D 0 values varied over a narrow range in the different phases of the cell cycle. These changes resulted from cyclic alterations in both aerobic and anaerobic D 0 values, possibly in n values. (author)

  3. Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields.

    Science.gov (United States)

    Kelaranta, Anna; Ekholm, Marja; Toroi, Paula; Kortesniemi, Mika

    2016-01-01

    Dental radiography may involve situations where the patient is known to be pregnant or the pregnancy is noticed after the X-ray procedure. In such cases, the radiation dose to the foetus, though low, needs to be estimated. Uniform and widely used guidance on dental X-ray procedures during pregnancy are presently lacking, the usefulness of lead shields is unclear and practices vary. Upper estimates of radiation doses to the foetus and breasts of the pregnant patient were estimated with an anthropomorphic female phantom in intraoral, panoramic, cephalometric and CBCT dental modalities with and without lead shields. The upper estimates of foetal doses varied from 0.009 to 6.9 μGy, and doses at the breast level varied from 0.602 to 75.4 μGy. With lead shields, the foetal doses varied from 0.005 to 2.1 μGy, and breast doses varied from 0.002 to 10.4 μGy. The foetal dose levels without lead shielding were dental radiographic examination.

  4. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  5. Intercomparison of the medium energy primary standards for X-ray exposure of NPL and ENEA, Italy

    International Nuclear Information System (INIS)

    Moretti, C.J.; Heaton, J.A.; Laitano, R.F.; Toni, M.P.

    1991-04-01

    An intercomparison between the primary standards of exposure for medium energy X-rays held by the National Physical Laboratory (NPL) and ENEA in Italy is described. The intercomparison, using four different transfer chambers, took place at NPL in December 1989 and at ENEA during March 1990. Measurements were made at four therapy-level qualities, with half value layers of 0.15, 0.5, 1.0 and 2.5 mm Cu (nominal generating voltages of 100, 135, 180 and 250 kV respectively). At the 2.5 mm Cu HVL quality the primary standards were found to agree to within about 0.8%; for the other three qualities the chambers differed by no more than 0.3%. (author)

  6. Effect of continuous exposure to very low dose rates of gamma rays on life span and neoplasia in mice

    International Nuclear Information System (INIS)

    Tanaka, I.B. III; Tanaka, Satoshi; Ichinohe, Kazuaki; Matsumoto, Tsuneya; Otsu, Hiroshi; Oghiso, Yoichi; Sato, Fumiaki; Matsushita, Satoru

    2008-01-01

    Late effects of continuous exposure to ionizing radiation are potential hazards to workers in radiation facilities as well as to the general public. In the recent years, low-dose-rate and low-dose effects have become a serious concern. Using a total of 4,000 mice, we studied the late biological effects of chronic exposure to low-dose-rate radiation on life span and neoplasia. Two thousand male and 2000 female 8-week-old specific pathogen free (SPF) B6C3F1 mice were randomly divided into 4 groups, one non-irradiated (control) and three irradiated. The irradiated groups were exposed to 137 Cs gamma rays at dose-rates of 21, 1.1 and 0.05 mGy day -1 for approximately 400 days with total doses equivalent to 8000, 400 and 20 mGy, respectively. All mice were kept under SPF conditions until natural death and pathological examination was performed to determine the cause of death. Statistical analyses showed that the life spans of mice of both sexes irradiated with 21 mGy day -1 (P -1 (P 86.7% of all deaths. Compared to the non-irradiated controls, incidences of lethal neoplasms were significantly increased for myeloid leukaemia and hemangiosarcoma in males, soft tissue neoplasms and malignant granulosa cell tumors in females exposed to 21 mGy day -1 . The number of multiple primary neoplasms per mouse was significantly increased in mice irradiated at 21 mGy day -1 . Our results suggest that life shortening in mice continuously exposed to low dose-rate gamma rays is due to early death from a variety of neoplasms and not from increased incidence of specific lethal neoplasms. (author)

  7. Sex-dependent Differences in Intestinal Tumorigenesis Induced in Apc1638N/+ Mice by Exposure to {gamma} Rays

    Energy Technology Data Exchange (ETDEWEB)

    Trani, Daniela [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Maastricht Radiation Oncology (MaastRO) Lab, GROW-School for Oncology and Developmental Biology, University of Maastricht (Netherlands); Moon, Bo-Hyun [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Kallakury, Bhaskar; Hartmann, Dan P. [Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Datta, Kamal [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Fornace, Albert J., E-mail: af294@georgetown.edu [Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, District of Columbia (United States); Lombardi Comprehensive Cancer Center, Georgetown University Medical Center, Washington, District of Columbia (United States); Center of Excellence in Genomic Medicine Research (CEGMR), King Abdulaziz University, Jeddah (Saudi Arabia)

    2013-01-01

    Purpose: The purpose of the present study was to assess the effect of 1 and 5 Gy radiation doses and to investigate the interplay of gender and radiation with regard to intestinal tumorigenesis in an adenomatous polyposis coli (APC) mutant mouse model. Methods and Materials: Apc1638N/+ female and male mice were exposed whole body to either 1 Gy or 5 Gy of {gamma} rays and euthanized when most of the treated mice became moribund. Small and large intestines were processed to determine tumor burden, distribution, and grade. Expression of proliferation marker Ki-67 and estrogen receptor (ER)-{alpha} were also assessed by immunohistochemistry. Results: We observed that, with both 1 Gy and 5 Gy of {gamma} rays, females displayed reduced susceptibility to radiation-induced intestinal tumorigenesis compared with males. As for radiation effect on small intestinal tumor progression, although no substantial differences were found in the relative frequency and degree of dysplasia of adenomas in irradiated animals compared with controls, invasive carcinomas were found in 1-Gy- and 5-Gy-irradiated animals. Radiation exposure was also shown to induce an increase in protein levels of proliferation marker Ki-67 and sex-hormone receptor ER-{alpha} in both non tumor mucosa and intestinal tumors from irradiated male mice. Conclusions: We observed important sex-dependent differences in susceptibility to radiation-induced intestinal tumorigenesis in Apc1638N/+ mutants. Furthermore, our data provide evidence that exposure to radiation doses as low as 1 Gy can induce a significant increase in intestinal tumor multiplicity as well as enhance tumor progression in vivo.

  8. Tumours associated with medical X-ray therapy exposure in childhood

    International Nuclear Information System (INIS)

    Colman, M.; Kirsch, M.; Creditor, M.

    1978-01-01

    A total of 5166 persons who were exposed to limited field (80-100 cm 2 ) X-ray irradiation to the head, neck and upper chest region during childhood and adolescence have provided an outstanding opportunity for the study of tumour incidence following medical X-ray therapy. More than 3254 subjects have been traced, 3108 have completed questionnaires eliciting information on tumour incidence, and 1539 of these were subjected to a thorough clinical screening procedure that included a thyroid scintigram. The prevalence of thyroid tumours in the 1539 clinically screened subjects and the prevalence of all other tumours in the 3254 subjects traced can therefore be assumed to reflect the risks in the group of irradiated subjects as a whole. Median age at irradiation was 3.5 years, and median radiation dose 790 rads (7.9 Gy). Thyroid tumour was diagnosed in 413 subjects. Of those undergoing surgery (273) 30.3% were found to have thyroid cancer. A total of 366 surgical pathology specimens of the thyroid, including 93 from subjects who were diagnosed at other hospitals, were examined revealing 73 papillary carcinomas, 12 follicular carcinomas and 26 microscopic papillary carcinomas. One hundred and eighty-seven other (non-thyroid) neoplasmas identified included 27 benign and 10 malignant salivary gland tumours, 16 benign and seven malignant tumours of neural origin (brain, spinal cord, cranial and peripheral nerves), 37 skin tumours, 9 lymphomas, 8 gonadal tumours, 45 breast tumours and 28 tumours of miscellaneous sites. The incidence of thyroid tumours, salivary gland tumours and primary brain tumours was considerably in excess of the expected incidence (p values<0.0001), and a radiation dose-effect correlation was observed for thyroid and brain tumours. Gonadal tumours and lymphomas did not occur in excess of the expected incidence

  9. Evaluation of patient exposure with Flat Panel Detector (FPD) in X-ray TV system

    International Nuclear Information System (INIS)

    Yamada, M.; Komiya, N.; Kawaguchi, A.; Suzuki, M.; Suzuki, Shoichi; Asada, Yasuki

    2008-01-01

    The use of flat-panel detector (FPD) systems in TV equipment for gastrointestinal tract examination is increasing. The use of FPD systems is believed to reduce the exposure dose. When our institution changed its TV equipment from an image intensifier (GE; MS90Tj) system to an FPD (Shimadzu; SONIALVISION safire DAR-3500) system, we measured the doses produced and carried out a comparative examination of the extent to which exposure could be reduced. Two TV systems were used. We used an analyzer to measure output waveform, tube voltage, and half-value layer (HVL), and an ionization chamber dosimeter to carry out dose-in-air measurements. Body thickness, number of image acquisitions, and fluoroscopy time are required for the calculation of entrance skin dose (ESD). We therefore measured body thicknesses in 1000 upper gastrointestinal tract (UGI) and barium enemas and obtained average body thicknesses for males and females by age group. Values used for number of image acquisitions and fluoroscopy times were the averages in our institution over a two-year period. When an I.I. system was used, the average ESD during UGI examination were 126.8 mGy fluoroscopy dose and 11.62 mGy imaging dose, for an average total dose of 138.42 mGy per examination. ESD during barium enema averaged 201.73 mGy fluoroscopy dose and 45.2 mGy imaging dose, for an average total dose of 246.92 mGy per examination. When an FPD system was used, the average ESD during UGI examination were 58.71 mGy fluoroscopy dose and 5.72 mGy imaging dose, for an average total dose of 64.43 mGy per examination. ESD during barium enema averaged 112.21 mGy fluoroscopy dose and 24.55 mGy imaging dose, for an average total dose of 136.76 mGy per examination. The use of an FPD system reduced both fluoroscopy dose and imaging dose by 50%. The number of TV systems equipped with FPD in Japan has increased from around 1300 in 2006 to around 1700 in 2007. The use of FPD systems can be expected to increase in future. This

  10. Statistical investigation on frequency, duration, number of X-ray investigations and radiation exposure to the patients of a district hospital on the outskirts of Munich

    Energy Technology Data Exchange (ETDEWEB)

    Nordmann, W

    1973-04-10

    Within the framework of a dissertation, X-ray examined patients were statistically surveyed during one month at the district hospital. The radiation exposure of the patients increased strongly particularly with men of the age of 21 to 30 and of 61 to 70. The causes are the multiply performed investigations after accidents as well as angiography at greater ages. The exposure is in the case of women particularly high between the ages of 66 and 70. In determining the gonadal exposure, the average values for the X-ray investigation at the time were referred to. The numbers give an approximate idea of to what extent single investigations with varying investigation or picture frequency can contribute to gonadal exposure.

  11. Normal rejoining of DNA strand breaks in ataxia telangiectasia fibroblast lines after low x-ray exposure

    International Nuclear Information System (INIS)

    Hariharan, P.V.; Eleczko, S.; Smith, B.P.; Paterson, M.C.

    1981-01-01

    The alkaline elution method was used to measure the enzymatic repair of x-ray-induced DNA strand breaks in skin fibroblasts derived from human subjects afflicted with ataxia telangiectasia (AT). Monolayer cultures of normal control and AT cell lines were exposed acutely to moderately lethal (250-rad) and highly lethal (1250-rad) doses of 250-kV x rays under aerobic conditions. Upon receiving 250 rad, the control fibroblasts from a clinically normal donor rejoined all detectable single-strand breaks (plus alkali-labile bonds) within 30 to 60 min of incubation. When challenged with 1250 rad the kinetics of strand rejoining by the normal control cells were biphasic. For both exposures, no significant difference in either the rate or the extent of strand rejoining was detected between the normal cell line (GM38) and three mutant cell lines (AT2BE, AT3BI, AT4BI) belonging to the three known genetic complementation groups in AT. It would thus appear that the enhanced radiosensitivity of cultured AT cells does not stem from faulty rejoining of radiogenic DNA strand breaks

  12. A comprehensive study of the energy absorption and exposure buildup factors of different bricks for gamma-rays shielding

    Directory of Open Access Journals (Sweden)

    M.I. Sayyed

    Full Text Available The present investigation has been performed on different bricks for the purpose of gamma-ray shielding. The values of the mass attenuation coefficient (µ/ρ, energy absorption buildup factor (EABF and exposure buildup factor (EBF were determined and utilized to assess the shielding effectiveness of the bricks under investigation. The mass attenuation coefficients of the selected bricks were calculated theoretically using WinXcom program and compared with MCNPX code. Good agreement between WinXcom and MCNPX results was observed. Furthermore, the EABF and EBF have been discussed as functions of the incident photon energy and penetration depth. It has been found that the EABF and EBF values are very large in the intermediate energy region. The steel slag showed good shielding properties, consequently, this brick is eco-friendly and feasible compared with other types of bricks used for construction. The results in this work should be useful in the construction of effectual shielding against hazardous gamma-rays. Keywords: Brick, Mass attenuation coefficient, Buildup factor, G-P fitting, Radiation shielding

  13. Contribution of renal X-ray examinations to the radiation exposure to the population

    International Nuclear Information System (INIS)

    Radtke, I.; Koenig, W.; Menzel, B.

    1978-01-01

    Measured values of the radiation exposure of patients by urography published in the literature are summarized and critically reviewed. The gonad dose to men, women and children has been determined in 6 series of measurements performed according to the recommendations of the Gesellschaft fuer Medizinische Radiologie. Altogether, the determination of the gonad dose based on 927 individual measurements, 230 of them intravaginally, on 226 patients. The surface dose has been determined from 335 measurements. With exact collimation and shielding values of 250 mR for men and 650 mR for women have been obtained as the most probable ones. For 350,000 urographs equally distributed to both sexes and performed under correct working conditions an average per capita dose of 9.2 mR would result. (author)

  14. Contribution of renal X-ray examinations to the radiation exposure to the population

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, I [Staedtisches Klinikum Berlin-Buch (German Democratic Republic). Roentgendiagnostisches Zentrum; Angerstein, W [Forschungsinstitut fuer Tuberkulose und Lungenkrankheiten, Berlin (German Democratic Republic); Koenig, W; Menzel, B [Staatliches Amt fuer Atomsicherheit und Strahlenschutz, Berlin (German Democratic Republic)

    1978-04-02

    Measured values of the radiation exposure of patients by urography published in the literature are summarized and critically reviewed. The gonad dose to men, women and children has been determined in 6 series of measurements performed according to the recommendations of the Gesellschaft fuer Medizinische Radiologie. Altogether, the determination of the gonad dose based on 927 individual measurements, 230 of them intravaginally, on 226 patients. The surface dose has been determined from 335 measurements. With exact collimation and shielding values of 250 mR for men and 650 mR for women have been obtained as the most probable ones. For 350,000 urographs equally distributed to both sexes and performed under correct working conditions an average per capita dose of 9.2 mR would result.

  15. Hospital and clinic survey estimates of medical X-ray exposure in Hiroshima and Nagasaki, 2

    International Nuclear Information System (INIS)

    Antoku, Shigetoshi; Hoshi, Masaharu; Sawada, Shozo; Russell, W.J.

    1987-07-01

    The technical factors used during radiological examinations performed in Hiroshima and Nagasaki medical institutions were analyzed. The most frequently performed examination was chest radiography, followed by upper GI series. More than half the radiographic exposures were from upper GI series due to the many spot films made during fluoroscopy. Comparison of the present survey results with those of a previous one showed that relatively high kVp, low mAs and mA, and smaller field sizes are now more widely used. Though there have been decreased in fluoroscopy times and tube currents over the past 10 years, the numbers of spot films used have increased. Based on these technical factors, tables of organ doses from fluoroscopic examinations were compiled. (author)

  16. Establishment and verification of dose-response curve of chromosomal aberrations after exposure to very high dose γ-ray

    International Nuclear Information System (INIS)

    Chen Ying; Luo Yisheng; Cao Zhenshan; Liu Xiulin

    2006-01-01

    To estimate accurately biological dose of the victims exposed to high dose, the dose-response curves of chromosome aberration induced by 6-22 Gy 60 Co γ-ray were established. Human peripheral blood in vitro was irradiated, then lymphocytes were concentrated, cultured 52h, 68h and 72h and harvested. The frequencies of dicentrics (multi-centrics) and rings were counted and compared between different culture times. The dose-response curves and equations were established, as well as verified with high dose exposure accidents. The experiment showed that the culture time should be prolonged properly after high dose exposure, and no significant differences were observed between 52-72h culture. The dose-response curve of 6-22 Gy fitted to linear-square model Y=-2.269 + 0.776D - 7.868 x 10 -3 D 2 and is reliable through verification of the accident dose estimations. In this study, the dose-response curve and equation of chromosome dic + r after 6-22 Gy high dose irradiation were established firstly, and exact dose estimation can be achieved according to it. (authors)

  17. Staff and patient exposure to X-ray radiation during cardiac procedures

    International Nuclear Information System (INIS)

    Jankowski, J.; Papierz, D.; Domienik, J.; Kacprzyk, J.; Tybor-Czerwinska, M.; Werduch, A.

    2008-01-01

    The aim of this study was to define and compare staff and patient doses during the most common types of cardiac procedures. The influence of operators' technique and quality of X-ray unit in use on doses received by the staff and patients was investigated. The study was conduced in two independent hemodynamic rooms (I and II). The doses to hand for medical staff (operators and nurses) were monitored. For hand dose assessment, ring thermoluminescent dosimeters were used. Regarding patient dosimetry, dose-area product was collected for selected procedures. The monthly hand doses ranged from 0.4 mSv to 41.2 mSv in room I and from 0.1 to 8.95 mSv in room II. On the basis of the above measurements, the annual doses were estimated. The maximum annual hand doses for the operator and for the nurse in room I were 232.8 mSv/year and 11.5 mSv/year and in room II - 29.8 mSv/year and 14.1 mSv/year, respectively. Additionally, to compare the doses received by the particular medical operators, the doses were normalized to the total workload. Hand dose per procedure ranged from 109 to 614 μSv/procedure and were significantly larger in room I. The typical DAP values (median) recorded for the CA and CA+PTCA procedures were 55 Gy/cm 2 and 171 Gy/cm 2 in room I and 35 Gy/cm 2 and 87 Gy/cm 2 in the room II, respectively. As a result of this survey, the impact of medical operator's experience as well as technique and quality of available X-ray units on doses received by staff and patients has been proven. On the basis of the above results, the special need for monitoring hand doses for medical staff, apart from the effective dose, has been recognized. (author)

  18. Effects of fetal exposure to gamma rays on aggressive behavior in adult male mice

    International Nuclear Information System (INIS)

    Minamisawa, Takeru; Hirokaga, Kouichi; Sasaki, Shunsaku; Noda, Yutaka.

    1992-01-01

    Aggressive behavior (AB) in first generation (F 1 ) hybrid male C57BL/6 x C3H mice irradiated on the 14th day of gestation was studied at 100-135 days of age. Gravid female mice were irradiated with 1.0 or 2.0 Gy of gamma rays to the whole body. The AB of pairs of mice were recorded with a capacitance-induction motility monitor and on videotape. Recordings were continued for 90 min, starting at 2:00 PM. Vigorous wrestling, boxing and biting were regarded as AB. Data recorded at 15-min intervals were stored on micro-computer discs. The body weight for the irradiated group was significantly lower than that for the control group. The number of instances of AB was significantly higher in the irradiated group. The AB of the 2.0 Gy group was significantly more intensive than that of the control group. No difference in the duration of AB was found for the 2 irradiated and the control groups. Results demonstrate that male mice irradiated prenatally show increased aggressiveness. (author)

  19. Dicentric yields induced in rabbit blood lymphocytes after exposure in vitro to X-rays

    International Nuclear Information System (INIS)

    Inoue, Yoshinori

    1995-06-01

    For the purpose of biological dosimetry, it is essential to establish the relationship between dicentric yields and absorbed doses. The present experiment was carried out to obtain data for rabbit lymphocytes as a reference for this relationship. As data at low dose level are scanty, rabbit lymphocytes were exposed to various doses, especially below 0.5 Gy, of 150 kVp X-rays and analysed at their first mitotic division for dicentric yields. The yields at high dose level were compared with data reported by other authors. The linear-quadratic equation, which is generally accepted, for the dose-response relationship was obtained by the iteratively reweighted least squares method. However, as the present experiment result showed that the dose-response relationship at low dose-levels was likely to be linear, a dose-response line was calculated by the linear regression analysis. As the result of the chi-square tests, it was found that the dicentric yield was better fitted to the linear model at low doses below 0.5 Gy than the linear quadratic model. (author)

  20. Degradation of Albumin on Plasma-Treated Polystyrene by Soft X-ray Exposure

    Directory of Open Access Journals (Sweden)

    Nina Recek

    2016-06-01

    Full Text Available Thin films of human serum albumin (HSA were immobilized on polystyrene (PS substrates previously functionalized either with polar or nonpolar functional groups. The functionalization was performed by treatment with cold gaseous plasma created in pure oxygen and tetrafluoromethane (CF4 plasmas, respectively. Samples were examined with soft X-rays in the photon energy range of 520 to 710 eV in the ANTARES beam line at SOLEIL Synchrotron. NEXAFS spectra of O K-edge and F K-edge were collected at different spots of the sample, and measurements at each spot were repeated many times. A strong degradation of the HSA protein was observed. The weakly irradiated samples exhibited strong absorption at 531.5 eV associated with the O 1s→π*amide transitions, and a broad non distinctive peak at 540 eV was attributed to the O 1s→σ*C–O transitions. Both peaks decreased with increasing irradiation time until they were completely replaced by a broad non-distinctive peak at around 532 eV, indicating the destruction of the original protein conformation. The shortage of the amide groups indicated breakage of the peptide bonds.

  1. Study of the contribution of X-ray and gamma photons to the measured exposure dose

    International Nuclear Information System (INIS)

    Andriampanarivo, H.L.H.

    2000-01-01

    The aim of this work was to study the contribution of X-rays and gamma radiation to the measured dose in the city of Antananarivo. The annual indoor absorbed dose was studied as well. Measurements were carried out in twelve sites, namely public schools and churches. The mean dose rate lies between (0.34±0.03)μSv/h and (0.38±0.04)μSv/h for most of the sites. Two of them showed values between (0.40±0.04)μSv/h and (0.30±0.03)μSv/h. Mean indoor dose rate is of (0.36±0.04)μSv/h and the annual absorbed dose is (3.16±0.32)mSv/person. Indoor measurements showed mean integral values ranging from (277.22±0,22)cps to (733.66±0,37)cps. The lowest mean count rate is (277.22±0,22)cps, measured in the AMARO site, whereas the highest are (733,66±0,37)cps, (697,81±0,36)cps and (689,32±0,36)cps measured in ALO0 , AKELY, and MASINA respectively. [fr

  2. Study of the separate exposure method for bootstrap sensitometry on X-ray cine film

    International Nuclear Information System (INIS)

    Matsuda, Eiji; Sanada, Taizo; Hitomi, Go; Kakuba, Koki; Kangai, Yoshiharu; Ishii, Koushi

    1997-01-01

    We developed a new method for bootstrap sensitometry that obtained the characteristic curve from a wide range, with a smaller number of aluminum steps than the conventional bootstrap method. In this method, the density-density curve was obtained from standard and multiplied exposures to the aluminum step wedge and used for bootstrap manipulation. The curve was acquired from two regions separated and added together, e.g., lower and higher photographic density regions. In this study, we evaluated the usefulness of a new cinefluorography method in comparison with N.D. filter sensitometry. The shape of the characteristic curve and the gradient curve obtained with the new method were highly similar to that obtained with N.D. filter sensitometry. Also, the average gradient obtained with the new bootstrap sensitometry method was not significantly different from that obtained by the N.D. filter method. The study revealed that the reliability of the characteristic curve was improved by increasing the measured value used to calculate the density-density curve. This new method was useful for obtaining a characteristic curve with a sufficient density range, and the results suggested that this new method could be applied to specific systems to which the conventional bootstrap method is not applicable. (author)

  3. Surface Exposure Geochronology Using Cosmogenic Nuclides: Applications in Antarctic Glacial Geology

    Science.gov (United States)

    1994-02-01

    in rocks, are particularly promising for directly dating 1 geological surfaces . In 1934, Grosse et al. first suggested that cosmic rays produce rare...and muons produced by cosmic ray irteractions in the atmosphere and in rocks, and spallation by I neutrons produced in muon capture reactions (Kurz...stable isotopes are useful for surface 3 exposure studies because they can act as integrators of cosmic ray exposure on long time scales, potentially up

  4. Dental X-ray exposure and Alzheimer's disease: a hypothetical etiological association.

    Science.gov (United States)

    Rodgers, Caroline C

    2011-07-01

    Despite the fact that Alzheimer's disease was identified more than 100 years ago, its cause remains elusive. Although the chance of developing Alzheimer's disease increases with age, it is not a natural consequence of aging. This article proposes that dental X-rays can damage microglia telomeres - the structures at the end of chromosomes that determine how many times cells divide before they die - causing them to age prematurely. Degenerated microglia lose their neuroprotective properties, resulting in the formation of neurofibrillary tau tangles and consequently, the neuronal death that causes Alzheimer's dementia. The hypothesis that Alzheimer's is caused specifically by microglia telomere damage would explain the delay of one decade or longer between the presence of Alzheimer's brain pathology and symptoms; telomere damage would not cause any change in microglial function, it would just reset the countdown clock so that senescence and apoptosis occurred earlier than they would have without the environmental insult. Once microglia telomere damage causes premature aging and death, the adjacent neurons are deprived of the physical support, maintenance and nourishment they require to survive. This sequence of events would explain why therapies and vaccines that eliminate amyloid plaques have been unsuccessful in stopping dementia. Regardless of whether clearing plaques is beneficial or harmful - which remains a subject of debate - it does not address the failing microglia population. If microglia telomere damage is causing Alzheimer's disease, self-donated bone marrow or dental pulp stem cell transplants could give rise to new microglia populations that would maintain neuronal health while the original resident microglia population died. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Malformation of the cerebral cortex of rats caused by embryonal exposure to x-ray

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, M [Nagoya Univ. (Japan). Research Inst. of Environmental Medicine

    1978-03-01

    200 R x-ray was irradiated to rat embryos, 17 days of age, and changes of the brain were observed histologically from one hour after the irradiation until they grew up. At start, there was not a great damage in the formation of bundles of major and minor hemisphere commissure passing through the terminal plate, although many cells died or fell off in the new brain mantle. After that, callosal fibers did not reach the midline because of the tissue destruction around the midline, and growth of the stem of the corpus callosum was pressed down. Defect of the stem of the corpus callosum was recognized in adult rats. Surviving mother cells gathered irregularly on the wall of the ventricle at the time of the repair of destructed tissues, and they remained as they stood around the midline of the brain mantle without rearrangement. In adult rats, there was abnormal formation of the cerebral cortex within medullary substances. Marked hypoplasia was recognized in the II-IV layer of the new cortex, bundle branches of dendritic processes of pyramidal cells in the V layer were small in number, and the directions of dendritic processes were abnormal. Pyramidal cell layer of the hippocampus fell into disorder and the directions of dendritic processes were irregular. It was demonstrated by the measurement of cubic volume of each part of the brain using reconstruction method that not only marked hypoplasia of the new cortex and the hippocampus but also hypoplasia of the old cortex, the basal ganglion, and the thalamus in which it was thought to be little disorder in the past were clear.

  6. Malformation of the cerebral cortex of rats caused by embryonal exposure to x-ray

    International Nuclear Information System (INIS)

    Inoue, Minoru

    1978-01-01

    200 R x-ray was irradiated to rat embryos, 17 days of age, and changes of the brain were observed histologically from one hour after the irradiation until they grew up. At start, there was not a great damage in the formation of bundles of major and minor hemisphere commissure passing through the terminal plate, although many cells died or fell off in the new brain mantle. After that, callosal fibers did not reach the midline because of the tissue destruction around the midline, and growth of the stem of the corpus callosum was pressed down. Defect of the stem of the corpus callosum was recognized in adult rats. Surviving mother cells gathered irregularly on the wall of the ventricle at the time of the repair of destructed tissues, and they remained as they stood around the midline of the brain mantle without rearrangement. In adult rats, there was abnormal formation of the cerebral cortex within medullary substances. Marked hypoplasia was recognized in the II-IV layer of the new cortex, bundle branches of dendritic processes of pyramidal cells in the V layer were small in number, and the directions of dendritic processes were abnormal. Pyramidal cell layer of the hippocampus fell into disorder and the directions of dendritic processes were irregular. It was demonstrated by the measurement of cubic volume of each part of the brain using reconstruction method that not only marked hypoplasia of the new cortex and the hippocampus but also hypoplasia of the old cortex, the basal ganglion, and the thalamus in which it was thought to be little disorder in the past were clear. (Iwagami, H.)

  7. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  8. Obsidian dating prospects

    International Nuclear Information System (INIS)

    Ambrose, W.

    1997-01-01

    Full text: Developments in the nuclear industry have shown that some of the problems related to the glassification of waste for long term storage are centred on the rate of glass weathering in various repositories. Long term weathering of artificial glasses is paralleled by the archaeological problem of determining hydration rates in obsidian artefacts as a means of dating their manufacture. Figures available for sites in Papua New Guinea indicate that the weathering rate is sufficiently fast to render conventional hydration measurement completely unreliable. This follows from the range of calculated surface reduction rates which range between .0002μ to .004μ per year depending on the site's location and the obsidian source. Hydration rates for key Papua New Guinea obsidians have been determined from long term experimental laboratory exposure and these are used to evaluate the age of obsidians from selected archaeological sites. By adopting a strategy of measuring hydration in concealed fissures both the weathering rate and the dating of the Papua New Guinea obsidians have been successfully achieved. The dissolution rates of natural obsidians could be useful in considering weathering rates for artificial glasses. An improved system for calculating the annual effective hydration temperature is presented which gives a better control of micro-environmental temperature in its crucial rate determining role. The combined result of these developments gives obsidian hydration dating an enhanced capacity to be a useful and independent dating system

  9. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    Science.gov (United States)

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  10. Relationship medical exposure in X-ray diagnosis and loading factor and film/screen system for reduction exposure dose in Aomori. An analysis based on the results of questionnaire

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    A fact-finding questionnaire survey on medical exposure in Aomori Prefecture was conducted in September 1998. Of the 23 exposed sites in the body investigated, exposure at 17 sites in adults was investigated in terms of the type of high-voltage generator, imaging conditions (X-ray tube voltage, electric current, exposure time, etc.), photosensitive materials and relative photosensitivity, and entrance surface doses. At 6 of the 17 exposed sites, the relationships between these technical conditions and entrance surface doses were analyzed to consider further reduction of medical exposure. The most frequently used high-voltage generators were inverter generators (about 52%). In many institutions, additional filters were utilized for high-voltage imaging of the chest. Highly sensitive green-emission materials were the most frequently used photosensitive materials (73%). These findings indicate that many institutions are attempting to reduce exposure. Entrance surface doses varied greatly among institutions: and a 100-fold difference was observed in exposure to the chest, Martius, and the pelvis. Further efforts to lower entrance surface doses are therefore necessary to reduce medical exposure. Negative correlations were observed between electric voltage, electric current, and exposure time. Examination of the relationships between entrance surface doses, electric current, and exposure time yielded positive correlations. However, the entrance surface doses may not have been properly calculated in some institutions, and examination of the relationship between the relative sensitivity of the sensitive material and entrance surface doses showed great variability in entrance surface doses between institutions. Based on the above results, it is concluded that further reduction of medical exposure is possible, not only by improving the accuracy of X-ray units/devices, but by choosing a more appropriate of conditions to perform radiography. (K.H.)

  11. [Induction of micronuclei in peripheral blood and bone marrow reticulocytes of male mice after subchronic exposure to x-rays and bisphenol A].

    Science.gov (United States)

    Radzikowska, Joanna; Gajowik, Aneta; Dobrzyńska, Małgorzata

    2012-01-01

    Ionizing radiation and xenoestrogens are widely present in the human environment. Bisphenol A (BPA) is used to manufacture polycarbonate plastics, epoxy and polyester resins. BPA is present in a great variety of products including: baby bottles, compact disks, thermal paper, safety helmets, bullet resistant laminate, plastic windows, car parts, adhesives, protective coatings, powder paints, polycarbonate bottles and containers, the sheathing of electrical and electronic parts, dental fillings. Food and beverage cans are protected from rusting and corrosion by the application of epoxy resins as inner coatings. Human activities involving the use of radiation and radioactive materials in industry, agriculture and research cause radiation exposure in addition to natural exposure coming from cosmic rays and naturally occurring radioactive substances. The aim of the study was to estimate the effects of bisphenol A, X-rays and combined exposure to X-rays and bisphenol A on the induction of micronuclei in the peripheral blood and in bone marrow reticulocytes of laboratory mice. Pzh-Sfis male mice were exposed for 8 weeks. Animals were treated with bisphenol A diluted in drinking water (5 mg/kg bw, 10 mg/kg bw, 20 mg/kg bw), irradiated 0.05 Gy of X-rays or exposed to a combination of both (0.05 Gy + 5 mg/kg bw BPA). The samples of peripheral blood were taken at 1, 4 and 8 week following the start of exposure, whereas the bone marrow after the end of experiment, only. The induction of micronuclei in reticulocytes were evaluated by using fluorescence microscope. Bisphenol A as well as ionizing radiation stimulated induction of micronuclei in peripheral blood and bone marrow reticulocytes. After the irradiation the level of micronuclei increased, whereas after exposure to BPA decreased related to time expired from beginning of experiment. Combined exposure of ionizing radiation and bisphenol A induced significantly higher frequency of micronuclei compared to the effect

  12. Thermoluminescence dating of pottery

    International Nuclear Information System (INIS)

    Higashimura, Takenobu; Ichikawa, Yoneta.

    1978-01-01

    This report is divided into two parts. The first half describes on the history of thermoluminescence dating, and the latter half, the principle and measurement examples. It was in late 1955 that the measurement of radiation dose using thermoluminescence began. The method to thermoluminescence dating was developed when it was found that most natural stones emit the thermoluminescence. About Greek earthen wares, the study of which was presented in 1961 by G. Kennedy of University of California, the dating was able to be made within the standard deviation of 10%. Since then, this dating method progressed rapidly, and a number of laboratories are now forwarding the investigation. In the samples of natural materials, intensity of thermoluminescence I is proportional to natural radiation dose D which has been absorbed by the samples, i.e. I = kD, where k is the susceptibility of thermoluminescence of the samples. Since k is different in each sample, D can be determined by irradiating the sample with β or γ ray of known dose D 0 , measuring its luminescence I 0 , and eliminating k through these two equations, because i 0 = kD 0 . Next, if t is assumed to be the time passed since a pottery was made, D is expressed as Rt, where R is the natural radiation dose per year absorbed by the pottery. Thus t is determined if R is known. The report describes on the method of measuring R. As an example, the results of measurement of the potteries excavated at Iwakura remains, Yorikura, Taishaku-kyo, are listed. Results by 14 C dating are also described for reference. (Wakatsuki, Y.)

  13. Dose-response relationship of γ-H2AX foci induction in human lymphocytes after X-rays exposure

    International Nuclear Information System (INIS)

    Mandina, Tania; Roch-Lefevre, Sandrine H.; Voisin, Pascale; Gonzalez, Jorge E.; Lamadrid, Ana I.; Romero, Ivonne; Garcia, Omar; Voisin, Philippe; Roy, Laurence

    2011-01-01

    Biological dosimeters are recommended for dose estimation in case of human overexposure to ionising radiation. Rapid measurement of γ-H2AX foci as a marker of DNA double-strand breaks (DSB) induction has been recently tested with this purpose. Here we reported a dose-response relationship after X-ray irradiation at different times post-exposure. Blood samples were obtained from several healthy donors and exposed to doses between 0 and 2 Gy. After irradiation, blood samples were incubated at 37 deg. C during 0.5 h, 5 h, and 8 h. Scoring of cells and γ-H2AX foci was performed by software. The dose-response curves for different incubation times were as follows: Y (0.5h) = 11.66D + 0.15 (R 2 = 0.99), Y (5h) = 2.44D + 0.15 (R 2 = 0.99), Y (8h) = 1.57D + 0.22 (R 2 = 0.99). At 0.5 h post-exposure, the dose-response relationship for X-irradiated lymphocytes was similar to the one obtained after gamma-irradiation using the same protocol. On the other hand, the results were not similar after 8 h due to different kinetics after gamma- and X-irradiation. Our results confirm the possibilities of using γ-H2AX foci method for dose estimation in a period from 0.5 h up to 8 h post X-irradiation and support the hypothesis of differences in γ-H2AX foci kinetics after gamma- and X-irradiation in vitro.

  14. Radiation-induced signaling results in mitochondrial impairment in mouse heart at 4 weeks after exposure to X-rays.

    Science.gov (United States)

    Barjaktarovic, Zarko; Schmaltz, Dominik; Shyla, Alena; Azimzadeh, Omid; Schulz, Sabine; Haagen, Julia; Dörr, Wolfgang; Sarioglu, Hakan; Schäfer, Alexander; Atkinson, Michael J; Zischka, Hans; Tapio, Soile

    2011-01-01

    Radiation therapy treatment of breast cancer, Hodgkin's disease or childhood cancers expose the heart to high local radiation doses, causing an increased risk of cardiovascular disease in the survivors decades after the treatment. The mechanisms that underlie the radiation damage remain poorly understood so far. Previous data show that impairment of mitochondrial oxidative metabolism is directly linked to the development of cardiovascular disease. In this study, the radiation-induced in vivo effects on cardiac mitochondrial proteome and function were investigated. C57BL/6N mice were exposed to local irradiation of the heart with doses of 0.2 Gy or 2 Gy (X-ray, 200 kV) at the age of eight weeks, the control mice were sham-irradiated. After four weeks the cardiac mitochondria were isolated and tested for proteomic and functional alterations. Two complementary proteomics approaches using both peptide and protein quantification strategies showed radiation-induced deregulation of 25 proteins in total. Three main biological categories were affected: the oxidative phophorylation, the pyruvate metabolism, and the cytoskeletal structure. The mitochondria exposed to high-dose irradiation showed functional impairment reflected as partial deactivation of Complex I (32%) and Complex III (11%), decreased succinate-driven respiratory capacity (13%), increased level of reactive oxygen species and enhanced oxidation of mitochondrial proteins. The changes in the pyruvate metabolism and structural proteins were seen with both low and high radiation doses. This is the first study showing the biological alterations in the murine heart mitochondria several weeks after the exposure to low- and high-dose of ionizing radiation. Our results show that doses, equivalent to a single dose in radiotherapy, cause long-lasting changes in mitochondrial oxidative metabolism and mitochondria-associated cytoskeleton. This prompts us to propose that these first pathological changes lead to an increased

  15. Dose-response relationship of {gamma}-H2AX foci induction in human lymphocytes after X-rays exposure

    Energy Technology Data Exchange (ETDEWEB)

    Mandina, Tania [Centro de Proteccion e Higiene de las Radiaciones, Calle 20 No. 4113 e/41y 47 Miramar, AP 6195 C. Habana (Cuba); Roch-Lefevre, Sandrine H.; Voisin, Pascale [Institut de Radioprotection et de Surete Nucleaire (IRSN), DRPH, SRBE, LDB, BP17, 92262 Fontenay-aux-Roses (France); Gonzalez, Jorge E.; Lamadrid, Ana I.; Romero, Ivonne [Centro de Proteccion e Higiene de las Radiaciones, Calle 20 No. 4113 e/41y 47 Miramar, AP 6195 C. Habana (Cuba); Garcia, Omar, E-mail: omar@cphr.edu.cu [Centro de Proteccion e Higiene de las Radiaciones, Calle 20 No. 4113 e/41y 47 Miramar, AP 6195 C. Habana (Cuba); Voisin, Philippe; Roy, Laurence [Institut de Radioprotection et de Surete Nucleaire (IRSN), DRPH, SRBE, LDB, BP17, 92262 Fontenay-aux-Roses (France)

    2011-09-15

    Biological dosimeters are recommended for dose estimation in case of human overexposure to ionising radiation. Rapid measurement of {gamma}-H2AX foci as a marker of DNA double-strand breaks (DSB) induction has been recently tested with this purpose. Here we reported a dose-response relationship after X-ray irradiation at different times post-exposure. Blood samples were obtained from several healthy donors and exposed to doses between 0 and 2 Gy. After irradiation, blood samples were incubated at 37 deg. C during 0.5 h, 5 h, and 8 h. Scoring of cells and {gamma}-H2AX foci was performed by software. The dose-response curves for different incubation times were as follows: Y{sub (0.5h)} = 11.66D + 0.15 (R{sup 2} = 0.99), Y{sub (5h)} = 2.44D + 0.15 (R{sup 2} = 0.99), Y{sub (8h)} = 1.57D + 0.22 (R{sup 2} = 0.99). At 0.5 h post-exposure, the dose-response relationship for X-irradiated lymphocytes was similar to the one obtained after gamma-irradiation using the same protocol. On the other hand, the results were not similar after 8 h due to different kinetics after gamma- and X-irradiation. Our results confirm the possibilities of using {gamma}-H2AX foci method for dose estimation in a period from 0.5 h up to 8 h post X-irradiation and support the hypothesis of differences in {gamma}-H2AX foci kinetics after gamma- and X-irradiation in vitro.

  16. Unbiased Scanning Method and Data Banking Approach Using Ultra-High Performance Liquid Chromatography Coupled with High-Resolution Mass Spectrometry for Quantitative Comparison of Metabolite Exposure in Plasma across Species Analyzed at Different Dates.

    Science.gov (United States)

    Gao, Hongying; Deng, Shibing; Obach, R Scott

    2015-12-01

    An unbiased scanning methodology using ultra high-performance liquid chromatography coupled with high-resolution mass spectrometry was used to bank data and plasma samples for comparing the data generated at different dates. This method was applied to bank the data generated earlier in animal samples and then to compare the exposure to metabolites in animal versus human for safety assessment. With neither authentic standards nor prior knowledge of the identities and structures of metabolites, full scans for precursor ions and all ion fragments (AIF) were employed with a generic gradient LC method to analyze plasma samples at positive and negative polarity, respectively. In a total of 22 tested drugs and metabolites, 21 analytes were detected using this unbiased scanning method except that naproxen was not detected due to low sensitivity at negative polarity and interference at positive polarity; and 4'- or 5-hydroxy diclofenac was not separated by a generic UPLC method. Statistical analysis of the peak area ratios of the analytes versus the internal standard in five repetitive analyses over approximately 1 year demonstrated that the analysis variation was significantly different from sample instability. The confidence limits for comparing the exposure using peak area ratio of metabolites in animal plasma versus human plasma measured over approximately 1 year apart were comparable to the analysis undertaken side by side on the same days. These statistical analysis results showed it was feasible to compare data generated at different dates with neither authentic standards nor prior knowledge of the analytes.

  17. Saffron extracts effect on processes in brain structures under exposure to x-ray irradiation of medium dose

    International Nuclear Information System (INIS)

    Rzaeva, A.

    2012-01-01

    Full text : Process of ionizing radiation on live organism is accompanied by interaction of free radicals (FR) with molecules of proteins, nucleic acids and lipids. In its turn, FR occurs subsequently by excitation and ionization of molecules. Besides all, ionizing radiation becomes the reason of accumulation in body tissues of toxic products (radio toxic) that strengthen beam effect. Endogenous antioxidatic system (EAS) of an organism plays a significant role in detoxication of redundant quantity of FR formed in cells. Ionizing radiation influences negatively to high-grade functioning of basic EAS enzymes. Besides, during radiation injuries, the level of FR increases. In case of its exhaustion and lack insertion of natural antioxidants (bioantioxidants) to organism plays a therapeutic role. Thus, in our work we used saffron extract in experiments with the purpose of studying its effect on the activity of antioxidant enzymes at radiation influence. Determination of proteins has been carried out with Lowry method. In the result of carried-out researches, it has been detected fixed dynamics of activity change of antioxidant enzymes in various brain structures of white rats within x-ray irradiation at medium dose, and joint impact of x-ray radiation of saffron extract. Under exposure to X-ray irradiation of medium dose in some brain structures decreasing of catalase activity was revealed. Tendency towards decreasing is more developed on the 3th day of irradiation. As opposed to catalase activity GPO activity was increased. Insertion of saffron extract to experimental animals (for 21 days before irradiation) conducive to prevention the decreasing of catalase activity stabilizes GPO activity and exerts an effective influence. Thereby, bioantioxidants have significant role in the regulation of processes occurred in tissues and cells under the influence of extreme factors. Antioxidant protection system of organism carries out continuous protection of organism from toxic

  18. PRELIMINARY RESULTS IN SYNCHROTRON X-RAY DIFFRACTION MEASUREMENTS OF RUBBER COMPOSITES STRUCTURE BEFORE AND AFTER EXPOSURE TO HYDROGEN

    Directory of Open Access Journals (Sweden)

    Francesca Cosmi

    2011-05-01

    Full Text Available In future years, fuel cells are expected to represent a promising technology as a source of heat and electricity in buildings and of electrical power for vehicles, since fossil fuels are exhausting and significantly degrade air quality. It is well known that, when exposed to a hydrogen environment, hydrogen embrittlerment may affect materials such as iron and steel. But these are not the only materials that are used for hydrogen equipment. In particular, the rubber materials used for O–rings that seal high pressure hydrogen gas equipment show problems of internal fracture, called blister fracture, when the gas is rapidly decompressed. As many different kinds of fillers can be used, in this work we started to investigate the influence of the type of filler on the rubber composites structure, by means of X-ray diffraction measurements performed at the Elettra synchrotron radiation facility in Trieste. In this preliminary study, three kinds of samples were analyzed before and after exposure to hydrogen: Sulphur vulcanized EPDM, Peroxide vulcanized EPDM and Sulphur vulcanized NBR. While Peroxide vulcanized samples did not show significant differences in the diffraction pattern, changes could be detected in the cristalline form of Sulfure vulcanized rubber.

  19. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Izdihar Kamal

    2015-05-01

    Full Text Available Objectives: The aim of this research was to examine the average glandular dose (AGD of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. Methods: This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50 and 20% glandular and 80% adipose tissue (20/80 commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA with auto-time, auto-filter and auto-kilovolt modes. Results: The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy for two dimension (2D and 2.48 mGy for three dimensional (3D images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. Conclusion: The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  20. Santa Lucia (2008) (L6) Chondrite, a Recent Fall: Composition, Noble Gases, Nitrogen and Cosmic Ray Exposure Age

    Science.gov (United States)

    Mahajan, Ramakant R.; Varela, Maria Eugenia; Joron, Jean Louis

    2016-04-01

    The Santa Lucia (2008)—one the most recent Argentine meteorite fall, fell in San Juan province, Argentina, on 23 January 2008. Several masses (total ~6 kg) were recovered. Most are totally covered by fusion crust. The exposed interior is of light-grey colour. Chemical data [olivine (Fa24.4) and low-Ca pyroxene (En77.8 Fs20.7 Wo1.6)] indicate that Santa Luica (2008) is a member of the low iron L chondrite group, corresponding to the equilibrated petrologic type 6. The meteorite name was approved by the Nomenclature Committee (NomCom) of the Meteoritical Society (Meteoritic Bulletin, no. 97). We report about the chemical composition of the major mineral phases, its bulk trace element abundance, its noble gas and nitrogen data. The cosmic ray exposure age based on cosmogenic 3He, 21Ne, and 38Ar around 20 Ma is comparable to one peak of L chondrites. The radiogenic K-Ar age of 2.96 Ga, while the young U, Th-He are of 1.2 Ga indicates that Santa Lucia (2008) lost radiogenic 4He more recently. Low cosmogenic (22Ne/21Ne)c and absence of solar wind noble gases are consistent with irradiation in a large body. Heavy noble gases (Ar/Kr/Xe) indicated trapped gases similar to ordinary chondrites. Krypton and neon indicates irradiation in large body, implying large pre-atmospheric meteoroid.

  1. Noble gases, nitrogen, cosmic ray exposure history and mineralogy of Beni M'hira (L6) chondrite

    Science.gov (United States)

    Mahajan, Ramakant R.; Nejia, Laridhi Ouazaa; Ray, Dwijesh; Naik, Sekhar

    2018-03-01

    The concentrations and isotopic composition of noble gases helium (He), neon (Ne), argon (Ar), krypton (Kr), xenon(Xe) and nitrogen were measured in the Beni M'hira L6 chondrite. The cosmic ray exposure age of Beni M'hira is estimated of 15.6 ± 3.7 (Ma). The radiogenic age, of around 485 ± 64 Ma, derived from 4He, and of around 504 ± 51 Ma from 40Ar, suggests an age resetting indicating the event impact. The heavy noble gases (Ar, Kr and Xe) concentrations imply that the gas is a mixture of trapped component Q and solar wind. The measured nitrogen abundance of 0.74 ppm and the isotopic signature of δ15N = 14.6‰ are within the range of ordinary chondrites. The homogeneous chemical composition of olivine (Fa:26 ± 0.25) and low-Ca pyroxene (Fs:22.4 ± 0.29) suggest that the Beni M'hira meteorite is an equilibrated chondrite. This is further corroborated by strong chondrule-matrix textural integration (lack of chondrules, except a few relict clast). Shock metamorphism generally corresponds to S5 (>45 GPa), however, locally disequilibrium melting (shock-melt veins) suggests, that the peak shock metamorphism was at ∼75 GPa, 950 °C.

  2. Radiation risk to the patient: a case study involving multiple diagnostic X ray exposures given over a period of 25 years

    International Nuclear Information System (INIS)

    Rainbow, A.J.; McMaster Univ., Hamilton, ON; Roginski, P.; McGeen, W.

    1992-01-01

    The cumulative somatic dose index (SDI) for a number of diagnostic X ray examinations was made for a 60 year old male. The history of diagnostic X ray exposure for this patient from 1957 to 1983 showed 29 diagnostic X ray examinations including more than 100 films and 15 minutes of fluoroscopy. The total cumulative SDI to this patient was 214 mGy (about 21 rad). More than half this dose, 142 mGy, was contributed from upper GI and barium enema examinations which used fluoroscopy, with 88 mGy from the fluoroscopy alone. Using the recently revised risk coefficient for fatal cancer following whole-body irradiation of adult workers recommended by the International Commission on Radiological Protection in 1990, the authors estimate a 0.9% cancer morality risk to this patient resulting from the 29 diagnostic X ray examinations. (author)

  3. Isotopic Evidence for Multi-stage Cosmic-ray Exposure Histories of Lunar Meteorites: Long Residence on the Moon and Short Transition to the Earth

    International Nuclear Information System (INIS)

    Hidaka, Hiroshi; Sakuma, Keisuke; Nishiizumi, Kunihiko; Yoneda, Shigekazu

    2017-01-01

    It is known that most lunar meteorites have complicated cosmic-ray exposure experiences on the Moon and in space. In this study, cosmic-ray irradiation histories of six lunar meteorites, Dhofar 489, Northwest Africa 032 (NWA 032), NWA 479, NWA 482, NWA 2995, and NWA 5000, were characterized from neutron-captured isotopic shifts of Sm and Gd, and from the abundances of long-lived cosmogenic radionuclides like 10 Be, 26 Al, 36 Cl, and 41 Ca. Sm and Gd isotopic data of all of six meteorites show significant isotopic shifts of 149 Sm– 150 Sm and 157 Gd– 158 Gd caused by accumulation of neutron capture reactions due to cosmic-ray irradiation, corresponding to the neutron fluences of (1.3–9.6) × 10 16 n cm −2 . In particular, very large Sm and Gd isotopic shifts of NWA 482 are over those of a lunar regolith 70002, having the largest isotopic shifts among the Apollo regolith samples, corresponding to cosmic-ray exposure duration over 800 million years in the lunar surface (2 π irradiation). Meanwhile, the concentrations of cosmogenic radionuclides for individual six meteorites show the short irradiation time less than one million years as their bodies in space (4 π irradiation). Our data also support the results of previous studies, revealing that most of lunar meteorites have long exposure ages at shallow depths on the Moon and short transit times from the Moon to the Earth.

  4. In vivo x-ray fluorescence of bone lead in the study of human lead metabolism: Serum lead, whole blood lead, bone lead, and cumulative exposure

    International Nuclear Information System (INIS)

    Cake, K.M.; Chettle, D.R.; Webber, C.E.; Gordon, C.L.

    1995-01-01

    Traditionally, clinical studies of lead's effect on health have relied on blood lead levels to indicate lead exposure. However, this is unsatisfactory because blood lead levels have a half-life of approximately 5 weeks, and thus reflect recent exposure. Over 90% of the lead body burden is in bone, and it is thought to have a long residence time, thus implying that measurements of bone lead reflect cumulative exposure. So, measurements of bone lead are useful in understanding the long-term health effects of lead. Ahlgren reported the first noninvasive measurements of bone lead in humans, where γ-rays from 57 Co were used to excite the K series x-rays of lead. The lead detection system at McMaster University uses a 109 Cd source which is positioned at the center of the detector face (HPGe) and a near backscatter (∼160 degrees) geometry. This arrangement allows great flexibility, since one can sample lead in a range of different bone sites due to a robust normalization technique which eliminates the need to correct for bone geometry, thickness of overlying tissue, and other related factors. The effective radiation dose to an adult during an x-ray fluorescence bone lead measurement is extremely low, being 35 nSv. This paper addresses the issue of how bone, whole blood, and serum lead concentrations can be related in order to understand a person's lead exposure history

  5. Near-term and late biological effects of acute and low-dose-rate continuous gamma-ray exposure in dogs and monkeys

    International Nuclear Information System (INIS)

    Spalding, J.F.; Holland, L.M.

    1979-07-01

    Monkeys (Macaca mulatta) and dogs (beagle) were given thirteen 100-rad gamma-ray doses at 28-day intervals. The comparative response (inury and recovery) of the hematopoietic system of the two species was observed at 7-day intervals during the exposure regime. At 84 days after the thirteenth gamma-ray dose, the 1300-rad conditioned and control dogs and monkeys were challenged continuously with gamma rays at 35 r/day until death to determine the amount of radiation-induced injry remaining in conditioned animals as a reduction in mean survival time. Dogs (50%) and monkeys (8%) died from injury incurred during conditioning exposures. Thus, the comparative response (in terms of lethality) of dogs and monkeys to dose protraction by acute dose fractionation was similar to what we would expect from a single acute dose. The mean survival times for nonconditioned dogs and monkeys during continuous exposure at 35 R/day were the same (approx. 1400 h). Thus, the hematopoietic response of the two species by this method of dose protraction was not significantly different. Mean survival times of conditioned dogs and monkeys during the continuous 35-R/day gamma-ray challenge exposure were greater (significant in dogs but not in monkeys) than for their control counterparts. Thus, long-term radiation-induced injury was not measurable by this method. Conditioning doses of more than 4 times the acute LD 50 30 in dogs and approximately 2 times that in monkeys served only to increase both mean survival time and variance in a gamma-ray stress environment with a dose rate of 35 Rat/day

  6. Dating and Sexual Feelings

    Science.gov (United States)

    ... Home Body Your sexuality Dating and sexual feelings Dating and sexual feelings Thinking about romance, starting to ... you learn how to stay healthy and strong. Dating older guys top If you date someone even ...

  7. Setting a date

    International Nuclear Information System (INIS)

    Moore, Glenis.

    1987-01-01

    Dating techniques are discussed and explained. The age range and sensitivity of different techniques are given. Potassium/argon dating, amino-acid dating, radiocarbon dating, dendrochronology, thermoluminescence and geomagnetic field dating are all mentioned. Each technique is explained and a brief history given. The techniques and equipment used by the British Museum, and some examples of archaeological articles dated are mentioned. (UK)

  8. Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

    Science.gov (United States)

    Laohaudomchok, Wisanti; Cavallari, Jennifer M; Fang, Shona C; Lin, Xihong; Herrick, Robert F; Christiani, David C; Weisskopf, Marc G

    2010-08-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM(2.5) deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman rho = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the portable XRF could be used as an effective and reliable tool for exposure assessment in many studies.

  9. Radioresistant cell strain of human fibrosarcoma cells obtained after long-term exposure to X-rays

    International Nuclear Information System (INIS)

    Wei, K.; Kodym, R.

    1998-01-01

    A radioresistant cell strain from human fibrosarcoma HT1080 has been obtained after prolonged exposure to x-rays for 7 months (2 Gy per day, 5 days per week). This new strain, HT1080R, differs from HT1080 in a significantly increased ability of clonogenical survival, with coefficient α decreasing from 0.161 to 0.123 Gy -1 and coefficient β decreasing from 0.0950 to 0.0565 Gy -2 . Furthermore, the radioresistance of HT1080R proved to be stable in long-term passaged cultures as well as in frozen samples. Differences between the two cell lines are also observed in the G-banded karyotype; the new cell line shows monosomy of chromosome 17 and loss of 5p + and 11q + present in the parental cells. These data suggest that the radioresistance may have been caused by radiation-induced cell mutation and that the resistant cells may have been selected by repeated irradiations. In order to characterize this new strain, the ability of the cells to rejoin DNA double-strand breaks, the cell cycle distribution and the amount of apoptosis after irradiation have been estimated; however, no differences are observed between these two cell strains. Although the mechanism of the elevated radioresistance remains unknown, this pair of cell strains can provide a new model system for further investigations with regard to the mechanisms of cellular radioresistance. The results also show that any type of irradiation similar to the schedules used in radiotherapy can lead to the formation and selection of more radioresistant cell clones in vitro, a phenomenon with possible implications for radiotherapy. (orig.)

  10. 4D synchrotron X-ray imaging to understand porosity development in shales during exposure to hydraulic fracturing fluid

    Science.gov (United States)

    Kiss, A. M.; Bargar, J.; Kohli, A. H.; Harrison, A. L.; Jew, A. D.; Lim, J. H.; Liu, Y.; Maher, K.; Zoback, M. D.; Brown, G. E.

    2016-12-01

    Unconventional (shale) reservoirs have emerged as the most important source of petroleum resources in the United States and represent a two-fold decrease in greenhouse gas emissions compared to coal. Despite recent progress, hydraulic fracturing operations present substantial technical, economic, and environmental challenges, including inefficient recovery, wastewater production and disposal, contaminant and greenhouse gas pollution, and induced seismicity. A relatively unexplored facet of hydraulic fracturing operations is the fluid-rock interface, where hydraulic fracturing fluid (HFF) contacts shale along faults and fractures. Widely used, water-based fracturing fluids contain oxidants and acid, which react strongly with shale minerals. Consequently, fluid injection and soaking induces a host of fluid-rock interactions, most notably the dissolution of carbonates and sulfides, producing enhanced or "secondary" porosity networks, as well as mineral precipitation. The competition between these mechanisms determines how HFF affects reactive surface area and permeability of the shale matrix. The resultant microstructural and chemical changes may also create capillary barriers that can trap hydrocarbons and water. A mechanistic understanding of the microstructure and chemistry of the shale-HFF interface is needed to design new methodologies and fracturing fluids. Shales were imaged using synchrotron micro-X-ray computed tomography before, during, and after exposure to HFF to characterize changes to the initial 3D structure. CT reconstructions reveal how the secondary porosity networks advance into the shale matrix. Shale samples span a range of lithologies from siliceous to calcareous to organic-rich. By testing shales of different lithologies, we have obtained insights into the mineralogic controls on secondary pore network development and the morphologies at the shale-HFF interface and the ultimate composition of produced water from different facies. These results

  11. Evaluating X-ray absorption of nano-bismuth oxide ointment for decreasing risks associated with X-ray exposure among operating room personnel and radiology experts

    Directory of Open Access Journals (Sweden)

    M. Rashidi

    2015-12-01

      Conclusion: It seems that due to higher atomic number and lower toxicity, Bi2O3 nanoparticles have better efficiency in X-ray absorbtion, comparing to the lead. Cream and ointment of bismuth oxide nanoparticles can be used as X-ray absorbant for different professions such as physicians, dentists, radiology experts, and operating room staff and consequently increase health and safety of these employees.

  12. Analysis of patients' X-ray exposure in 146 percutaneous radiologic gastrostomies; Analyse der Strahlenexposition fuer Patienten bei 146 perkutanen radiologischen Gastrostomien

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael [Univ. Hospital Leipzig (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-09-15

    Analysis of patient's X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. The median DFP of PRG-placements under fluoroscopy was 163 cGy{sup *}cm{sup 2} (flat panel detector systems: 155 cGy{sup *}cm{sup 2}; X-ray image intensifier: 175 cGy{sup *}cm{sup 2}). The median DLZ was 2.2min. Intraprocedural placement of a naso- or orogastric probe (n=68) resulted in a significant prolongation of the median DLZ to 2.5min versus 2min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n=7, median DFP=2635 cGy{sup *}cm{sup 2}), or using CT (n=4, median DLP=657mGy{sup *}cm). Estimates of the median DFP and DLP showed effective doses of 0.3mSv for DL-assisted placements (flat panel detector 0.3mSv, X-ray image converter 0.4mSv), 7.9mSv using a CBCT - flat detector, and 9.9mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe significantly extends FT, but has little effect on the overall dose of the

  13. The influence of plutonium exposure and lung cancer on the frequency of x-ray-induced micronuclei in dog blood lymphocytes

    International Nuclear Information System (INIS)

    Brooks, A.L.; Rithidech, K.; Muggenburg, B.A.; Lozano, D.; Lundgren, D.L.

    1988-01-01

    This study determined if lung cancer or exposure to an inhaled alpha emitter, plutonium-239, increased the frequency of micronuclei in blood lymphocytes or altered the responsiveness of lymphocytes to induction of micronuclei by subsequent doses of X rays in vitro. Beagle dogs inhaled 1.5 mm ABAD monodisperse 239 PuO 2 aerosols. The exposure resulted in initial lung burdens of 1.8 KBq to 48 KBq and produced cumulative alpha radiation lung doses of 1.4 to 10.4 Gy at the time of this study. Blood lymphocytes were sampled and irradiated with either 0.0 or 2.0 Gy of X rays. The lymphocytes were stimulated to divide by phytohemagglutinin, cytokinesis was blocked with cytochalasin B, and the frequency of micronuclei was determined in binucleated cells. Plutonium inhalation alone produced no significant increase in the frequency of micronuclei in blood lymphocytes. When 2 Gy of X rays ws given to blood lymphocytes of dogs that had inhaled 239 PuO 2 , there was a linear increase in micronuclei frequency as a function of alpha dose to the lungs; micronuclei/binucleated cell = 0.15 +0.2 D, where D is the cumulative alpha-radiation dose to the lung in Gy. Dogs with 239 PuO 2 - induced lung cancer did not have a significant increase in the frequency of X- ray-induced micronuclei relative to dogs exposed to plutonium that did not have lung cancer. These data suggest that inhaled 239 PuO 2 alters the responsiveness of blood lymphocytes to subsequent X-ray exposure. (author)

  14. Age evaluation and causation of rock-slope failures along the western margin of the Antrim Lava Group (ALG), Northern Ireland, based on cosmogenic isotope (36Cl) surface exposure dating

    Science.gov (United States)

    Southall, David W.; Wilson, Peter; Dunlop, Paul; Schnabel, Christoph; Rodés, Ángel; Gulliver, Pauline; Xu, Sheng

    2017-05-01

    The temporal pattern of postglacial rock-slope failure in a glaciated upland area of Ireland (the western margin of the Antrim Lava Group) was evaluated using both 36Cl exposure dating of surface boulders on run-out debris and 14C dating of basal organic soils from depressions on the debris. The majority of the 36Cl ages ( 21-15 ka) indicate that major failures occurred during or immediately following local deglaciation ( 18-17 ka). Other ages ( 14-9 ka) suggest some later, smaller-scale failures during the Lateglacial and/or early Holocene. The 14C ages (2.36-0.15 cal ka BP) indicate the very late onset of organic accumulation and do not provide close limiting age constraints. Rock-slope failure during or immediately following local deglaciation was probably in response to some combination of glacial debuttressing, slope steepening and paraglacial stress release. Later failures may have been triggered by seismic activity associated with glacio-isostatic crustal uplift and/or permafrost degradation consequent upon climate change. The 36Cl ages support the findings of previous studies that show the deglacial - Lateglacial period in northwest Ireland and Scotland to have been one of enhanced rock-slope failure. Table S2 Concentrations of main elements (as oxides) etc.

  15. Influence of occupational exposure to pesticides on the level of DNA damage induced in human lymphocytes (Polish group) by UV-C and X-rays

    International Nuclear Information System (INIS)

    Dyga, W.; Drag, Z.; Cebulska-Wasilewska, A.

    2002-01-01

    The aim of this study was to find out whether occupational exposure to pesticides might affect the individual susceptibility of various donors to the induction of DNA damage by genotoxic agents (UV-C, X-rays) and the efficiency of cellular repair. Previously cryo preserved lymphocytes were defrosted, and DNA damage in the lymphocytes prior to any in vitro studies was investigated with the application of the Comet assay. In order to evaluate the susceptibilities of human lymphocytes to genotoxic agents and the variability of repair capacities, the DNA migrations were estimated immediately after exposure to UV-C light or X-rays and after two hours. On average, the DNA damage detected in untreated lymphocytes was significantly higher in the group exposed to pesticides than in reference group. UV-C treated lymphocytes from group exposed to pesticides shows a greater statistically significant level of DNA migration compared to the reference group, detected after 2 hours incubation in the absence of PHA. Significantly lower responses to X-rays and higher levels of residual DNA damage were detected in the lymphocytes of donors from the group exposed to pesticides compared with the reference group. In conclusion, our results suggest that occupational exposure to pesticides influences the level of induced DNA damage, and the cellular capabilities of repair. (author)

  16. Developable images produced by x-rays using the nickel-hypophosphite system. 2: Exposure and development parameters for sodium hypophosphite

    Science.gov (United States)

    May, C. E.; Philipp, W. H.; Marsik, S. J.

    1972-01-01

    Crystalline sodium hypophosphite was X-irradiated and then treated with an ammoniacal nickel hypophosphite solution. Treatment resulted in the precipitation of nickel metal. The yield of nickel metal varied directly with particle size, sample weight, X-ray voltage, target current, exposure time, and development time. These findings show the process to be potentially useful in X-ray type photography. The half-life for the latent image species was found to be relatively short; but this is not critical in most X-ray photography applications. Furthermore, the work can be interpreted on the basis that a hydrogen atom is involved in the mechanism and indicates that the autocatalytic development step may be self-poisoning.

  17. Mutation induction in haploid yeast after split-dose radiation exposure. II. Combination of UV-irradiation and X-rays.

    Science.gov (United States)

    Keller, B; Zölzer, F; Kiefer, J

    2004-01-01

    Split-dose protocols can be used to investigate the kinetics of recovery from radiation damage and to elucidate the mechanisms of cell inactivation and mutation induction. In this study, a haploid strain of the yeast, Saccharomyces cerevisiae, wild-type with regard to radiation sensitivity, was irradiated with 254-nm ultraviolet (UV) light and then exposed to X-rays after incubation for 0-6 hr. The cells were incubated either on nutrient medium or salt agar between the treatments. Loss of reproductive ability and mutation to canavanine resistance were measured. When the X-ray exposure immediately followed UV-irradiation, the X-ray survival curves had the same slope irrespective of the pretreatment, while the X-ray mutation induction curves were changed from linear to linear quadratic with increasing UV fluence. Incubations up to about 3 hr on nutrient medium between the treatments led to synergism with respect to cell inactivation and antagonism with respect to mutation, but after 4-6 hr the two treatments acted independently. Incubation on salt agar did not cause any change in the survival curves, but there was a strong suppression of X-ray-induced mutation with increasing UV fluence. On the basis of these results, we suggest that mutation after combined UV and X-ray exposure is affected not only by the induction and suppression of DNA repair processes, but also by radiation-induced modifications of cell-cycle progression and changes in the expression of the mutant phenotype. Copyright 2004 Wiley-Liss, Inc.

  18. A theoretical model predicting the intensity of emitted light per unit of x-ray exposure in radiographic screens

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukos, S; Kateris, A; Kalivas, N; Spyrou, G; Panayiotakis, G [Department of Medical Physics, School of Medicine, University of Patras, 265 00 pAtras (Greece); Kandarakis, I; Gavouras, D [Department of Medical Instrumentation Technology, Technological Educational Institution of Athens (Greece)

    1999-12-31

    A theoretical model predicting the intensity of light emitted by x-ray imaging phosphor screens per unit of area and time over incident x-ray flux (absolute efficiency) was developed. The model takes into account : A) the structure of the screens which consists of luminescent grains embedded in a binding matrix. B) the direct deposition of energy by x-ray absorption effects.. C) the re-absorption of K fluorescence characteristic x-rays produced when the x-ray energy exceeds the energy of the K absorption edge of the phosphor material. To test the model a set of (Gd,La)2O2S:Tb phosphor screens was prepared by sedimentation in the laboratory. Experimental absolute efficiency data were obtained at x-ray tube voltage range from 40 to 160 kVp. The coincidence between experimental and theoretical results were satisfactory. (authors) 7 refs., 4 figs.

  19. The toxicity and anesthetic effect of sodium hydroxybutyrate and ketamine at different periods of the combined radiation injuy , burn trauma and x-ray exposure

    International Nuclear Information System (INIS)

    Il'yuchenok, T.Yu.; Rasulev, B.K.; Moiseeva, L.A.

    1985-01-01

    Mongreal mice have been used to study animal sensitivity under the conditions of combined radiation injury (CRI), separate burn and X-ray effect to sodium hydroxybutyrate and ketamine. It is shown that while administering these anes thetics the differences in the organism reaction depend on the stage of injury and form of exposure. The changes in anesthesia duration in the first days (1-st - 4-th) after radiation exposure are contrary to those at combined radiation-thermal injury and separate burn trauma. The anesthetic effect of ketamine increases under the conditions of combined radiation-thermal injury and is not changed at separate exposures; its toxicity, on the contrary, on the 30-th day after burn and irradiation is increased

  20. Myeloid leukaemia frequency after protracted exposure to ionizing radiation: experimental confirmation of the flat dose-response found in ankylosing spondylitis after a single treatment course with x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Mole, R H; Major, I R [Medical Research Council, Harwell (UK). Radiobiological Research Unit

    1983-01-01

    The dose-response for leukaemia induction by exposure to ionizing radiation protracted over several weeks was largely independent of dose not only in X-rayed patients with ankylosing spondylitis but also in experimentally ..gamma..-rayed CBA/H mice. In the experiment the induced leukaemia frequency of acute myeloid leukaemia was independent of a several thousand-fold variation in physical dose rate. Any difference in leukaemia induction between brief and protracted exposures must therefore depend on specifically biological consequences of protracted exposures. Experimental analysis is required to provide the guides for inference about risks of low level exposure from observations on relatively heavily irradiated populations.

  1. Isotopic Evidence for Multi-stage Cosmic-ray Exposure Histories of Lunar Meteorites: Long Residence on the Moon and Short Transition to the Earth

    Energy Technology Data Exchange (ETDEWEB)

    Hidaka, Hiroshi; Sakuma, Keisuke [Department of Earth and Planetary Sciences, Nagoya University Nagoya 464-8601 (Japan); Nishiizumi, Kunihiko [Space Sciences Laboratory, University of California, Berkeley, CA 94720-7450 (United States); Yoneda, Shigekazu, E-mail: hidaka@eps.nagoya-u.ac.jp [Department of Science and Engineering, National Museum of Nature and Science Tsukuba 305-0005 (Japan)

    2017-06-01

    It is known that most lunar meteorites have complicated cosmic-ray exposure experiences on the Moon and in space. In this study, cosmic-ray irradiation histories of six lunar meteorites, Dhofar 489, Northwest Africa 032 (NWA 032), NWA 479, NWA 482, NWA 2995, and NWA 5000, were characterized from neutron-captured isotopic shifts of Sm and Gd, and from the abundances of long-lived cosmogenic radionuclides like {sup 10}Be, {sup 26}Al, {sup 36}Cl, and {sup 41}Ca. Sm and Gd isotopic data of all of six meteorites show significant isotopic shifts of {sup 149}Sm–{sup 150}Sm and {sup 157}Gd–{sup 158}Gd caused by accumulation of neutron capture reactions due to cosmic-ray irradiation, corresponding to the neutron fluences of (1.3–9.6) × 10{sup 16} n cm{sup −2}. In particular, very large Sm and Gd isotopic shifts of NWA 482 are over those of a lunar regolith 70002, having the largest isotopic shifts among the Apollo regolith samples, corresponding to cosmic-ray exposure duration over 800 million years in the lunar surface (2 π irradiation). Meanwhile, the concentrations of cosmogenic radionuclides for individual six meteorites show the short irradiation time less than one million years as their bodies in space (4 π irradiation). Our data also support the results of previous studies, revealing that most of lunar meteorites have long exposure ages at shallow depths on the Moon and short transit times from the Moon to the Earth.

  2. Understanding Teen Dating Violence

    Science.gov (United States)

    Understanding Teen Dating Violence Fact Sheet 2014 Dating violence is a type of intimate partner violence. It occurs between two people in a close relationship. The nature of dating violence can be physical, emotional, or sexual. • Physical— This ...

  3. Teen Dating Violence

    Science.gov (United States)

    ... Room Social Media Publications Injury Center Teen Dating Violence Recommend on Facebook Tweet Share Compartir On This ... serious forms of violence. What is teen dating violence? Teen Dating Violence [550 KB, 2 Pages, 508] ...

  4. Microscale radiocarbon dating of paintings

    International Nuclear Information System (INIS)

    Hendriks, Laura; Hajdas, Irka; McIntyre, Cameron; Kueffner, Markus; Ferreira, Ester S.B.; Scherrer, Nadim C.

    2016-01-01

    In this paper, radiocarbon dating of paintings using minimal sample sizes has been investigated, in an effort to address the problem of limited access to sample material in paintings. 14 C analyses were conducted on signed and dated paintings from two Swiss artists of the twentieth century. The selected paintings dated from the 1930s and 1960s, provided the opportunity to evaluate the dating accuracy on paintings realized before and after 1950 AD when the 14 C bomb peak was created, as a result of the nuclear tests conducted in the 1950/1960s. The work focused on the one hand on minimizing the size of the canvas sample required for accelerator mass spectrometer radiocarbon measurement on the gas ion source of the MICADAS and, on the other hand, on testing the possibility of dating the organic binder of the paint. Following careful characterization of the paint composition by X-ray fluorescence spectroscopy, Fourier transformed infrared spectroscopy, and Raman spectroscopy, paints containing no other carbon source than the natural organic binder were identified and dated. (orig.)

  5. Microscale radiocarbon dating of paintings

    Energy Technology Data Exchange (ETDEWEB)

    Hendriks, Laura; Hajdas, Irka; McIntyre, Cameron [ETH Zurich, Ion Beam Physics, Zurich (Switzerland); Kueffner, Markus; Ferreira, Ester S.B. [SIK-ISEA, Zurich, Zurich (Switzerland); Scherrer, Nadim C. [Bern University of Applied Sciences, HKB, Bern (Switzerland)

    2016-03-15

    In this paper, radiocarbon dating of paintings using minimal sample sizes has been investigated, in an effort to address the problem of limited access to sample material in paintings. {sup 14}C analyses were conducted on signed and dated paintings from two Swiss artists of the twentieth century. The selected paintings dated from the 1930s and 1960s, provided the opportunity to evaluate the dating accuracy on paintings realized before and after 1950 AD when the {sup 14}C bomb peak was created, as a result of the nuclear tests conducted in the 1950/1960s. The work focused on the one hand on minimizing the size of the canvas sample required for accelerator mass spectrometer radiocarbon measurement on the gas ion source of the MICADAS and, on the other hand, on testing the possibility of dating the organic binder of the paint. Following careful characterization of the paint composition by X-ray fluorescence spectroscopy, Fourier transformed infrared spectroscopy, and Raman spectroscopy, paints containing no other carbon source than the natural organic binder were identified and dated. (orig.)

  6. Radiokrypton dating coming of age

    Institute of Scientific and Technical Information of China (English)

    Zheng-Tian Lu

    2016-01-01

    The dream of radiokrypton dating began in 1969 when Heinz Hugo Loosli and Hans Oeschger of the University of Bern first detected the decay of81Rr(half-life=230 000 yr)in krypton gas extracted from air[1].This isotope is produced in the upper atmosphere by cosmic-ray-induced spallation and neutron-activation of stable krypton.Due to its long residence time(105 yr)in the atmosphere,81Rr is uniformly

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to ...

  8. Progress in radiocarbon dating

    International Nuclear Information System (INIS)

    Hedges, R.E.M.

    1985-01-01

    The article concerns radiocarbon dating, the most important method for dating in archaeology. The principles and practice of the dating method are described. Recent developments in radiocarbon dating due to technical advances, are discussed, and include radiometric counting of small samples and accelerator mass spectrometry. Carbon isotopes and the environment are also discussed. (U.K.)

  9. Determining optimum wavelength of ultraviolet rays to pre-exposure of non-uniformity error correction in Gafchromic EBT2 films

    Science.gov (United States)

    Katsuda, Toshizo; Gotanda, Rumi; Gotanda, Tatsuhiro; Akagawa, Takuya; Tanki, Nobuyoshi; Kuwano, Tadao; Noguchi, Atsushi; Yabunaka, Kouichi

    2018-03-01

    Gafchromic films have been used to measure X-ray doses in diagnostic radiology such as computed tomography. The double-exposure technique is used to correct non-uniformity error of Gafchromic EBT2 films. Because of the heel effect of diagnostic x-rays, ultraviolet A (UV-A) is intended to be used as a substitute for x-rays. When using a UV-A light-emitting diode (LED), it is necessary to determine the effective optimal UV wavelength for the active layer of Gafchromic EBT2 films. This study evaluated the relation between the increase in color density of Gafchromic EBT2 films and the UV wavelengths. First, to correct non-uniformity, a Gafchromic EBT2 film was pre-irradiated using uniform UV-A radiation for 60 min from a 72-cm distance. Second, the film was irradiated using a UV-LED with a wavelength of 353-410 nm for 60 min from a 5.3-cm distance. The maximum, minimum, and mean ± standard deviation (SD) of pixel values of the subtraction images were evaluated using 0.5 inches of a circular region of interest (ROI). The highest mean ± SD (8915.25 ± 608.86) of the pixel value was obtained at a wavelength of 375 nm. The results indicated that 375 nm is the most effective and sensitive wavelength of UV-A for Gafchromic EBT2 films and that UV-A can be used as a substitute for x-rays in the double-exposure technique.

  10. Dynamic changes of peripheral blood T-lymphocyte DNA-Synthesis in rabbits after fractionated and single exposure to 60Co-γ rays

    International Nuclear Information System (INIS)

    Wang Zongwu; Chen Tiehe; Yu Zhijie; Han Ling; Pan Yusha; Su Fuqiang

    1988-01-01

    The experiments in 59 rabbits γ-irradiated with doses of 0, 0.5, 1.0, 2.0, and 3.0 Gy in fractional and single exposure to 60 Co-γ rays were reported, respectively · Dynamics of the changes of DNA-Synthesis in T-lymphocytes of peripheral blood was obserced during 29 days after γ-irradiation. Marked inhibition in DNA-synthesis was found on 1st day after irradiation. Recovery was observed in 3rd day after irradiation. The levels of DNA-synthesis before irradiation was recovered on 7th day after exposure for all groups. For fractionated irradiation, however, an increase, rather than a decrese, of DNA-synthesis was in the group of 1.0 Gy

  11. The effect of embryonic and fetal exposure to x-ray, microwaves, and ultrasound: Counseling the pregnant and nonpregnant patient about these risks

    International Nuclear Information System (INIS)

    Brent, R.L.

    1989-01-01

    The term radiation evokes emotional responses both from lay persons and from professionals. Many spokespersons are unfamiliar with radiation biology or the quantitative nature of the risks. Frequently, microwave, ultrasound, and ionizing radiation risks are confused. Although it is impossible to prove no risk for any environmental hazard, it appears that exposure to microwave radiation below the maximal permissible levels present no measurable risk to the embryo. Ultrasound exposure from diagnostic ultrasonographic-imaging equipment also is quite innocuous. It is true that continued surveillance and research into potential risks of these low-level exposures should continue; however, at present ultrasound not only improves obstetric care, but also reduces the necessity of diagnostic x-ray procedures. In the field of ionizing radiation, we have a better comprehension of the biologic effects and the quantitative maximum risks than for any other environmental hazard. Although the animal and human data support the conclusion that no increases in the incidence of gross congenital malformations, IUGR, or abortion will occur with exposures less than 5 rad, that does not mean that there are definitely no risks to the embryo exposed to lower doses of radiation, Whether there exists a linear or exponential dose-response relationship or a threshold exposure for genetic, carcinogenic, cell-depleting, and life-shortening effects has not been determined. It is obvious that the risks of 1-rad (.10Gy) or 5-rad (.05Gy) acute exposure are far below the spontaneous risks of the developing embryo because 15% of human embryos abort, 2.7% to 3.0% of human embryos have major malformations, 4% have intrauterine growth retardation, and 8% to 10% have early- or late-stage onset genetic disease. 92 references

  12. Use of lead aprons - further considerations of estimation of doses and conditions of acute exposures of TLD badge in diagnostic x-ray institutions

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.

    2003-01-01

    In the recent study the authors reported that the exposure conditions of the use of the TLD badge, whether worn under or over the lead apron could be estimated from the readout of the TLD badge used in X-ray diagnostic departments. The effectiveness of lead aprons procured from different suppliers having the same value of quoted nominal lead equivalence was found to vary severely and this indicated some limitation in the applicability of the method of evaluation of exposure conditions of the badge. The transmission factors for the lead aprons varied up to a factor of 15 for the same value of quoted nominal lead equivalence procured from three different suppliers. This is of serious consequences in radiation protection and attracts attention for quality control. An error in the estimation of the exposure conditions of the TLD badge could lead to an underestimation of doses up to 4 times using the prevalent method. The estimation of the actual doses of radiation workers in the cases of over-exposures for the situations of the use of the TLD badge over the lead apron showed that the variation in the quality of lead aprons could be wrong in the range from 1.6 to 25 times even if the kVp of the machine is exactly known. Therefore, attempt should not be made to estimate the actual doses under lead apron from the readout of the TLD badge worn over the apron, as the real values of the transmission factors of the aprons and kVp of the X-ray machine may not be available. (author)

  13. Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

    Science.gov (United States)

    den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R

    1994-06-01

    Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and

  14. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  15. Relationship between medical exposure and acquisition conditions during X-ray diagnosis of small children to reduce exposure doses in Aomori Prefecture. An analysis questionnaire

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    A questionnaire survey to determine the exposure dose of each site imaged was performed by the Aomori Association of Radiological Technologists in September 1998. Based on the results, the relation between the entrance surface dose and loading factor and film/screen system during chest and hip joint imaging of children was analyzed, and reduction of the exposure dose was assessed. The entrance surface dose was calculated by a non-dosimeter dosimetry (NDD) method. A slight correlation was observed between tube voltage and the product of tube current x imaging time for chest imaging, but not for hip joint imaging. No correlation was observed between the entrance surface dose and tube current x imaging time for chest imaging, but a positive correlation was observed for hip joint imaging. The rates at which an inverter device, a three-phase device, and a single-phase device were used as the high-voltage generator for chest imaging were 57.5%, 30.0%, 12.5%, respectively, and 57.0%, 26.0%, and 17.0%, respectively, for hip joint imaging. The tube voltage ranged from 45 to 130 kV (mean: 70-80 kV) for chest imaging, and from 45 to 74 kV (mean: 60 kV) for hip joint imaging. The tube current ranged from 100 to 800 mA (mean: 300 mA) for chest imaging, and from 50 to 650 mA (mean: 200 mA) for hip joint imaging. The mean entrance surface dose for chest imaging was smaller (1/3-1/5) than for hip joint imaging. The maximal difference in entrance surface dose between facilities was 39.0 times, the minimal difference was 18.4 times, and the difference was less than half of the difference in adults. The rates at which photosensitive materials were used was 8% blue luminescence 8%, green luminescence 76%. Many facilities used photosensitive materials whose the relative sensitivity was approximately 250. It was concluded that reduction of the exposure doses during imaging of children had been thoroughly considered at each facility. Dose reduction was concluded to be possible by using

  16. Response of TLD badge for the estimation of exposure conditions in diagnostic x-ray departments - use of lead aprons

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.; Bakshi, A.K.

    2002-01-01

    The present study was undertaken to ascertain the conditions of exposure of the TLD badge and to evaluate the inaccuracy involved in the estimation of dose received by the worker using an averaged lead apron transmission factor for the use of the badge above lead apron

  17. TU-FG-209-09: Mathematical Estimation and Experimental Measurement of Patient Free-In-Air Skin Entrance Exposure During a Panoramic Dental X-Ray Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Errico, A; Behrman, R; Li, B [Boston University Medical Center, Boston, MA (United States)

    2016-06-15

    Purpose: To develop a simple mathematical model for estimating the patient free-in-air skin entrance exposure (SEE) during a panoramic dental x-ray that does not require the use of a head phantom. This eliminates issues associated with phantom centering and the mounting of a detector on the phantom for routine QC testing. Methods: We used a Sirona Orthophos XG panoramic radiographic unit and a Radcal Accu-Gold system for this study. A solid state detector was attached over the slit of the Orthophos’ sensor with the help of a custom-built jig. A single measurement of the free-in-air exposure at this position was taken over a full panoramic scan. A mathematical model for estimating the SEE was developed based upon this measurement, the system geometry, x-ray field beam width, and x-ray sweep angle. To validate the model, patient geometry was simulated by a 16 cm diameter PMMA CTDI phantom centered at the machine’s isocenter. Measurements taken on the phantom’s surface were made using a solid state detector with lead backing, an ion chamber, and the ion chamber with the phantom wrapped in lead to mitigate backscatter. Measurements were taken near the start position of the tube and at 90 degrees from the start position. Results: Using the solid state detector, the average SEE was 23.5+/−0.02 mR and 55.5+/−0.08 mR at 64 kVp and 73 kVp, respectively. With the lead-wrapping, the measurements from the ion chamber matched those of the solid state detector to within 0.1%. Preliminary results gave the difference between the mathematical model and the phantom measurements to be approximately 5% at both kVps. Conclusion: Reasonable estimates of patient SEE for panoramic dental radiography can be made using a simple mathematical model without the need for a head phantom.

  18. TU-FG-209-09: Mathematical Estimation and Experimental Measurement of Patient Free-In-Air Skin Entrance Exposure During a Panoramic Dental X-Ray Procedure

    International Nuclear Information System (INIS)

    Errico, A; Behrman, R; Li, B

    2016-01-01

    Purpose: To develop a simple mathematical model for estimating the patient free-in-air skin entrance exposure (SEE) during a panoramic dental x-ray that does not require the use of a head phantom. This eliminates issues associated with phantom centering and the mounting of a detector on the phantom for routine QC testing. Methods: We used a Sirona Orthophos XG panoramic radiographic unit and a Radcal Accu-Gold system for this study. A solid state detector was attached over the slit of the Orthophos’ sensor with the help of a custom-built jig. A single measurement of the free-in-air exposure at this position was taken over a full panoramic scan. A mathematical model for estimating the SEE was developed based upon this measurement, the system geometry, x-ray field beam width, and x-ray sweep angle. To validate the model, patient geometry was simulated by a 16 cm diameter PMMA CTDI phantom centered at the machine’s isocenter. Measurements taken on the phantom’s surface were made using a solid state detector with lead backing, an ion chamber, and the ion chamber with the phantom wrapped in lead to mitigate backscatter. Measurements were taken near the start position of the tube and at 90 degrees from the start position. Results: Using the solid state detector, the average SEE was 23.5+/−0.02 mR and 55.5+/−0.08 mR at 64 kVp and 73 kVp, respectively. With the lead-wrapping, the measurements from the ion chamber matched those of the solid state detector to within 0.1%. Preliminary results gave the difference between the mathematical model and the phantom measurements to be approximately 5% at both kVps. Conclusion: Reasonable estimates of patient SEE for panoramic dental radiography can be made using a simple mathematical model without the need for a head phantom.

  19. The Antarctica component of postglacial rebound model ICE-6G_C (VM5a) based on GPS positioning, exposure age dating of ice thicknesses, and relative sea level histories

    Science.gov (United States)

    Argus, Donald F.; Peltier, W. R.; Drummond, R.; Moore, Angelyn W.

    2014-07-01

    A new model of the deglaciation history of Antarctica over the past 25 kyr has been developed, which we refer to herein as ICE-6G_C (VM5a). This revision of its predecessor ICE-5G (VM2) has been constrained to fit all available geological and geodetic observations, consisting of: (1) the present day uplift rates at 42 sites estimated from GPS measurements, (2) ice thickness change at 62 locations estimated from exposure-age dating, (3) Holocene relative sea level histories from 12 locations estimated on the basis of radiocarbon dating and (4) age of the onset of marine sedimentation at nine locations along the Antarctic shelf also estimated on the basis of 14C dating. Our new model fits the totality of these data well. An additional nine GPS-determined site velocities are also estimated for locations known to be influenced by modern ice loss from the Pine Island Bay and Northern Antarctic Peninsula regions. At the 42 locations not influenced by modern ice loss, the quality of the fit of postglacial rebound model ICE-6G_C (VM5A) is characterized by a weighted root mean square residual of 0.9 mm yr-1. The Southern Antarctic Peninsula is inferred to be rising at 2 mm yr-1, requiring there to be less Holocene ice loss there than in the prior model ICE-5G (VM2). The East Antarctica coast is rising at approximately 1 mm yr-1, requiring ice loss from this region to have been small since Last Glacial Maximum. The Ellsworth Mountains, at the base of the Antarctic Peninsula, are inferred to be rising at 5-8 mm yr-1, indicating large ice loss from this area during deglaciation that is poorly sampled by geological data. Horizontal deformation of the Antarctic Plate is minor with two exceptions. First, O'Higgins, at the tip of the Antarctic Peninsula, is moving southeast at a significant 2 mm yr-1 relative to the Antarctic Plate. Secondly, the margins of the Ronne and Ross Ice Shelves are moving horizontally away from the shelf centres at an approximate rate of 0.8 mm yr-1, in

  20. Radiation-hygienic assessment of theroid exposure in children resulted from X-ray examination of chest organs

    International Nuclear Information System (INIS)

    Kostenetskij, M.I.

    1983-01-01

    Radiation doses for thyroid in children in the case of X-ray examination of chest organs with the aim of optimization of investigation regimes are studied. Dosimetric measurements are performed in aqueous plexiglass phantoms imitating children of different age. It is shown that the maximum radiation dose for thyroid is registered in breast-fed children and constitutes, about 50% of the annual radiation background; in the older age it constiturotes 8-10% of the natural annual radiation backgund. The increase of intensity at the X-ray tube with the simultaneous decrease of explosure in the case of constant filtration of radiation gives the increase of radiation dose of thyroid in breast-fed children are inconsiderable; in older children, approximately in 1.7 times

  1. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schirmer, A. [Arbeitsgruppe Aufklarung der Arbeitsplatzverhaltnisse Radar, Wehrbereichsverwaltung Nord, Bundeswehr, Munster (Germany)

    2006-07-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H{sup *}(10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  2. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    International Nuclear Information System (INIS)

    Schirmer, A.

    2006-01-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H * (10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  3. Structural and histochemical considerations of parotid gland from adult rats (Holtzmann) submitted to x-rays exposure

    International Nuclear Information System (INIS)

    Sposto, M.R.

    1988-01-01

    A histomorphological and histochemical study of the parotid gland of adult rats was carried out after subjecting the animals to a single X-ray irradiation dose of 900 R directed to the cervical region. The samples for the histological analysis were obtained at 2, 7, 15, 21, 30 and 45 days after radiation through desiccation and removal of the glands. The results showed clearly that the parotid gland is quite sensitive to X-ray irradiation with the serous acinar cells presenting heavier injuries than the mucous ones. A maximum in the deleterial action of the irradiation was detected at 15 days during the observation period. A comparative analysis of the glandular ducts showed that both of the types intercalated and striated were damaged, with the last presenting severe alterations in morphology and volume. By interpretation of the histochemical results it was concluded that a reduction in protein metabolism of the parotid gland occurred as a consequence of the X-ray irradiation. (author)

  4. Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants

    International Nuclear Information System (INIS)

    Schneider, Karl; Seidenbusch, M.C.

    2010-01-01

    Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be reduced in the last 30 years by a factor of 5 to 8. They are far below the entrance dose values reported by other radiology departments in Europe. Nevertheless, a slight increase in the entrance doses that correlates with the introduction of a digital storage phosphor system could be observed in the last years. Conclusion: because nearly all radiosensitive body organs in early life are involved during a thoracoabdominal babygram and because of the high radiation sensitivity of newborns, thoracoabdominal babygrams should be performed in neonatology with caution. A dose value of 1.0 cGy cm 2 could serve as the actual reference dose value for the thoracoabdominal babygram of the newborn. (orig.)

  5. Phenotypic and Functional Changes Induced in Hematopoietic Stem/Progenitor Cells After Gamma-Ray Radiation Exposure

    Energy Technology Data Exchange (ETDEWEB)

    Simonnet, A.J.; Nehme, J.; Leboulch, Ph.; Tronik-Le Roux, D. [Institute of Emerging Diseases and Innovative Therapies, Functional Bioengineering Laboratory, Commissariat a l' Energie Atomique (CEA), Evry (France); Simonnet, A.J.; Nehme, J.; Leboulch, Ph.; Tronik-Le Roux, D. [Institut National de la Sante et de la Recherche Medicale (INSERM) U733 (Unite Mixte de Recherche) - UMR INSERM CEA Paris XI (France); Vaigot, P. [Institute of Cellular and Molecular Radiation Biology, Department of Genetic Instability, Recombination and Repair, Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France); Vaigot, P. [UMR 217, UMR-CEA-Centre National de la Recherche Scientifique (France); Barroca, V. [Laboratory of Gametogenesis, Apoptosis, Genotoxicity, Institute of Cellular and Molecular Radiation Biology, Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France); Barroca, V. [Institut National de la Sante et de la Recherche Medicale U566 - UMR INSERM-CEA-PARIS VII (France); Leboulch, Ph. [Genetics Division, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (US)

    2009-07-01

    Ionizing radiation (IR) exposure causes rapid and acute bone marrow (BM) suppression that is reversible for nonlethal doses. Evidence is accumulating that IR can also provoke long-lasting residual hematopoietic injury. To better understand these effects, we analyzed phenotypic and functional changes in the stem/progenitor compartment of irradiated mice over a 10-week period. We found that hematopoietic stem cells (HSCs) identified by their repopulating ability continued to segregate within the Hoechst dye excluding 'side population (SP)' early after IR exposure. However, transient phenotypic changes were observed within this cell population: Sca-1 (S) and c-Kit (K) expression levels were increased and severely reduced, respectively, with a concurrent increase in the proportion of SPSK cells positive for established indicators of the presence of HSCs: CD150 and CD105. Ten weeks after IR exposure, expression of Sca-1 and c-Kit at the SP cell surface returned to control levels, and BM cellularity of irradiated mice was restored. However, the c-Kit{sup +}Sca-1{sup +}Lin{sup -/low} (KSL) stem/progenitor compartment displayed major phenotypic modifications, including an increase and a severe decrease in the frequencies of CD150{sup +}Flk2{sup -} and CD150{sup -}Flk2{sup +} cells, respectively. CD150{sup +} KSL cells also showed impaired reconstituting ability, an increased tendency to apoptosis, and accrued DNA damage. Finally, 15 weeks after exposure, irradiated mice, but not age matched controls, allowed engraftment and significant hematopoietic contribution from transplanted con-genic HSCs without additional host conditioning. These results provide novel insight in our understanding of immediate and delayed IR-induced hematopoietic injury and highlight similarities between HSCs of young irradiated and old mice. (authors)

  6. Phenotypic and Functional Changes Induced in Hematopoietic Stem/Progenitor Cells After Gamma-Ray Radiation Exposure

    International Nuclear Information System (INIS)

    Simonnet, A.J.; Nehme, J.; Leboulch, Ph.; Tronik-Le Roux, D.; Simonnet, A.J.; Nehme, J.; Leboulch, Ph.; Tronik-Le Roux, D.; Vaigot, P.; Vaigot, P.; Barroca, V.; Barroca, V.; Leboulch, Ph.

    2009-01-01

    Ionizing radiation (IR) exposure causes rapid and acute bone marrow (BM) suppression that is reversible for nonlethal doses. Evidence is accumulating that IR can also provoke long-lasting residual hematopoietic injury. To better understand these effects, we analyzed phenotypic and functional changes in the stem/progenitor compartment of irradiated mice over a 10-week period. We found that hematopoietic stem cells (HSCs) identified by their repopulating ability continued to segregate within the Hoechst dye excluding 'side population (SP)' early after IR exposure. However, transient phenotypic changes were observed within this cell population: Sca-1 (S) and c-Kit (K) expression levels were increased and severely reduced, respectively, with a concurrent increase in the proportion of SPSK cells positive for established indicators of the presence of HSCs: CD150 and CD105. Ten weeks after IR exposure, expression of Sca-1 and c-Kit at the SP cell surface returned to control levels, and BM cellularity of irradiated mice was restored. However, the c-Kit + Sca-1 + Lin -/low (KSL) stem/progenitor compartment displayed major phenotypic modifications, including an increase and a severe decrease in the frequencies of CD150 + Flk2 - and CD150 - Flk2 + cells, respectively. CD150 + KSL cells also showed impaired reconstituting ability, an increased tendency to apoptosis, and accrued DNA damage. Finally, 15 weeks after exposure, irradiated mice, but not age matched controls, allowed engraftment and significant hematopoietic contribution from transplanted con-genic HSCs without additional host conditioning. These results provide novel insight in our understanding of immediate and delayed IR-induced hematopoietic injury and highlight similarities between HSCs of young irradiated and old mice. (authors)

  7. Reconstruction of the Exposure Histories of 20 Allan Hills Ordinary Chondrites on the Basis of Cosmogenic 10Be, 26Al, Noble Gases, and Cosmic Ray Tracks

    Science.gov (United States)

    Neupert, U.; Knauer, M.; Michel, R.; Loeken, Th.; Schultz, L.; Dittrich-Hannen, B.; Suter, M.; Kubik, P. W.; Metzler, K.; Romstedt, J.

    1995-09-01

    Twenty ordinary chondrites from the 1988/89 meteorite search (ALH 88004, 88008, 88010, 88011, 88013, 88016 to 88021, 88026 to 88031, 88033, 88039, 88042) [1,2] were investigated for 10Be and 26Al, and for He, Ne and Ar by accelerator and rare gas mass spectrometry, respectively. Cosmic ray tracks were measured in samples of ALH 88019. Using theoretical production rates calculated by a physical model [3] the experimental data are interpreted with respect to the reconstruction of the preatmospheric exposure conditions and exposure histories of the meteoroids. Ordinary chondrites are particularly well suited to exemplify the capabilities of an interpretation of many cosmogenic nuclides measured in one sample. Model calculations of GCR production rates were performed for 10Be, 26Al, 3He, 21Ne, 22Ne and 38Ar as reported elsewhere [4,5]. For all meteorites, except for ALH 88019, the cosmogenic nuclide data can be explained by simple one stage exposure histories between 3 Ma and 44 Ma in meteoroids with radii between 5 cm and 85 cm. Exposure ages were derived from cosmogenic 3He, 21Ne and 38Ar on the basis of the theoretical production rates as function of3He/21Ne and 22Ne/21Ne as well as on the empirical ones proposed by Eugster [6]. The average ratios of exposure ages determined from theoretical production rates to those calculated according to Eugster [6] were 1.08+/-0.11, 1.11+/-0.25 and 1.12+/-0.17 in case of 3He, 21Ne and 38Ar, respectively. Repeated measurements of 10Be and 26Al in ALH 88019 resulted in 10.4+/-1.3 dpm/kg and 5.6+/-0.5 dpm/kg, respectively. But, the cosmogenic rare gas concentrations point to a (single stage) exposure age of 39 Ma in a meteoroid. This is in accordance with a measured cosmic ray track density in olivine of 2.8 * 10^6 cm^-2. The samples are from depths betwen 3 cm and 8 cm. Based on the track data we obtain a minimum meteoroid radius of 8 cm. The low 10Be and 26Al cannot be explained by a one stage exposure history and a long

  8. Dose response curve for prematurely condensed chromosome fragments of human lymphocytes after 60Co-γ ray exposure

    International Nuclear Information System (INIS)

    Gao Jinsheng; Zheng Siying; Bao Hong

    1992-06-01

    The dose-effect relationship of premature condensed chromosome fragments in human lymphocytes irradiated by 60 Co gamma ray was studied by PCC method (premature condensed chromosomes). In addition, The conventional cellular genetics method was also used in the study. The response curve of both methods can represented by two linear equations. The ratio of two slopes, K PCC /K M1 , is about 28. Comparing with conventional method, the PCC method has many advantages such as faster, simpler, more sensitive and accurate. The PCC method used in the studying of radiation damage is also discussed

  9. Tests for radiation protection in X-Ray mammography room for professional and non-professional exposure

    International Nuclear Information System (INIS)

    Naidenov, I.; Skocheva, A.

    2006-01-01

    Full text: Control tests for radiation protection of medical diagnostic rooms in our country are based on the guidelines to the use of x-rays in medicine and on the basic safety standards for radiation protection. The mammography room tests are not supported by basic data (such as normal conditions for testing and secondary limits) which to allow the developing of methods as the case is with the conventional x-ray rooms. The material presents and discusses over the situation of the matter with the aim to find solution of the problem. In mammography units the space distribution of the dose field of the object scattering radiation is not symmetrical, the maximum being in a direction opposite to the primary beam. Control tests were made for stray radiation in major (in the plane of beam rotation) test points in five rooms with mammography units of different producers and generation, under angles of scattering from the direction of the beam of 900 (horizontal table - 0 deg projection) and 1630 (tilt table - 730 deg projection). The results on the stray radiation show up to four times higher values in the 730 projection, the remaining conditions being the same. Normalization to the week loading used in the shielding design, like the comparison with secondary limits as published in the available norms do not give unambiguous idea. It is advisable to use this projection in control tests for radiation protection and the values shall be compared with the secondary limits of the corresponding standard loading

  10. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  11. Correlates of minimal dating.

    Science.gov (United States)

    Leck, Kira

    2006-10-01

    Researchers have associated minimal dating with numerous factors. The present author tested shyness, introversion, physical attractiveness, performance evaluation, anxiety, social skill, social self-esteem, and loneliness to determine the nature of their relationships with 2 measures of self-reported minimal dating in a sample of 175 college students. For women, shyness, introversion, physical attractiveness, self-rated anxiety, social self-esteem, and loneliness correlated with 1 or both measures of minimal dating. For men, physical attractiveness, observer-rated social skill, social self-esteem, and loneliness correlated with 1 or both measures of minimal dating. The patterns of relationships were not identical for the 2 indicators of minimal dating, indicating the possibility that minimal dating is not a single construct as researchers previously believed. The present author discussed implications and suggestions for future researchers.

  12. Dating of cremated bones

    OpenAIRE

    Lanting, JN; Aerts-Bijma, AT; van der Plicht, J; Boaretto, E.; Carmi, I.

    2001-01-01

    When dating unburnt bone, bone collagen, the organic fraction of the bone, is used. Collagen does not survive the heat of the cremation pyre, so dating of cremated bone has been considered impossible. Structural carbonate in the mineral fraction of the bone, however, survives the cremation process. We developed a method of dating cremated bone by accelerator mass spectrometry (AMS), using this carbonate fraction. Here we present results for a variety of prehistoric sites and ages, showing a r...

  13. Risk estimates for meningiomas and other late effects after diagnostic X-ray exposure of the skull

    International Nuclear Information System (INIS)

    Pflugbeil, S.; Pflugbeil, C.; Schmitz-Feuerhake, I.

    2011-01-01

    This study aims to investigate the contribution of diagnostic exposures to the rising rates of brain tumours and other neoplasms which are observed in several industrial nations. Included are benign tumours in the head and neck region and cataracts which are neglected in usual risk estimates by international and national radiation protection committees. Dose-effect relationships for tumours of the brain, skin, thyroid and other sites of the head region, leukaemia and cataracts are taken from the literature. Risk estimates are derived for paediatric head computed tomographies (CTs) as well as for brain tumours in adults. On the basis of estimates for Germany about the number of head scans, the annual rate of radiation-induced diseases is calculated. About 1000 annual paediatric CT investigations of the skull will lead to about three excess neoplasms in the head region, i.e. the probability of an induced late effect must be suspected in the range of some thousands. Additionally, a relevant increase of cataracts must be considered. The radiation-induced occurrence of meningiomas and other brain tumours most probably contributes to the continuously increasing incidence of these diseases which is observed in several industrial nations, as well as the exposure of the bone marrow by CT to the increase of childhood leukaemia. (authors)

  14. Carbon 14 dating method

    International Nuclear Information System (INIS)

    Fortin, Ph.

    2000-01-01

    This document gives a first introduction to 14 C dating as it is put into practice at the radiocarbon dating centre of Claude-Bernard university (Lyon-1 univ., Villeurbanne, France): general considerations and recalls of nuclear physics; the 14 C dating method; the initial standard activity; the isotopic fractioning; the measurement of samples activity; the liquid-scintillation counters; the calibration and correction of 14 C dates; the preparation of samples; the benzene synthesis; the current applications of the method. (J.S.)

  15. Measurement and monitoring of entrance exposure dose rate in X-ray image intensifier television with dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J [Bezirkskrankenhaus Brandenburg (German Democratic Republic)

    1981-03-01

    For X-ray image intensifier television operation very low entrance dose rates (about 5.2 nA/kg) are stated and demanded, respectively. These required values are often manifold exceeded in practice so that a check seems to be necessary. It is shown and proved how these measurements can be performed with simple, generally available means of measurement in the radiological practice. For ZnCdS-image intensifiers should be considered that about 13 nA/kg for the large entrance size are not to be exceeded; for the CsI type lower values (factor 1.5) are practicable because of the twofold quantum absorption efficiency. Furthermore, some tests for a semiquantitative function check of the automatic dose rate control are proposed.

  16. Reproductive ability of female dogs (beagles) surviving a single, midlethal, whole-body x-ray exposure

    International Nuclear Information System (INIS)

    Andersen, A.C.; Rosenblatt, L.S.

    1976-01-01

    The ability of 82 irradiated and sham-treated female beagles to whelp and wean pups was tested over a major portion of their reproductive life span. The dogs were exposed to 290 or 300 R of x rays (250 kVp) either as young pups, prior to puberty, or at puberty. Although all of the irradiated dogs were fertile and produced approximately the same number of litters as controls, litters of the pup irradiated and prepubertal irradiated dams surviving throughout the study were smaller than those of controls by 17 and 9 percent, respectively. Pup survival was also reduced relative to controls; the number of pups weaned was 38 percent lower in the pup irradiated group and 18 percent lower in the prepubertal irradiated group, as compared with controls. The overall reproductive ability of dogs irradiated at puberty was similar to that of sham-treated controls

  17. Iron distribution in cancer cells following doxorubicin exposure using proton and X-ray synchrotron radiation microprobes

    International Nuclear Information System (INIS)

    Ortega, R.; Deves, G.; Bohic, S.; Simionovici, A.; Menez, B.; Bonnin-Mosbah, M.

    2001-01-01

    Chemical studies have shown that doxorubicin, a well-established anticancer agent, is a powerful iron chelator and the resultant iron-drug complex is an efficient catalyst of the conversion of hydrogen peroxide to the highly reactive hydroxyl radical. However, the intracellular complexation of doxorubicin with iron is still debated. Using nuclear microprobe analysis (NMPA), we previously observed in human ovarian cancer cells exposed to 20 μM iodo-doxorubicin (IDX) that iodine and iron cellular distributions were spatially correlated, suggesting a mechanism of intracellular iron chelation by the anthracycline compound. Because maximal plasma drug concentrations in patients are expected to be around 5 μM, NMPA and X-ray absorption near edge spectroscopy (XANES) experiments for iron speciation analysis were performed on cultured cells exposed to pharmacological doses of 2 μM IDX or doxorubicin

  18. Behavior analysis in consumer affairs: encouraging dental professionals to provide consumers with shielding from unnecessary X-ray exposure

    International Nuclear Information System (INIS)

    Greene, B.F.; Neistat, M.D.

    1983-01-01

    An unobtrusive observation system was developed to determine the extent to which dental professionals in two communities provided lead shielding to patients during X-ray exams. A lengthy baseline revealed low and irregular provision of shielding among half of these professionals. Subsequently, a program was undertaken by a consumer's group in which these professionals were requested to provide shielding and were given confidential feedback regarding its use during the baseline period. The provision of shielding dramatically increased at all offices and was maintained throughout a follow-up period extending to more than 9 months after the program's implementation. Little or no generalized effect was observed in the occurrence of three collateral behaviors that were also assessed throughout the study

  19. Differential Bystander Signaling Between Radioresistant Chondrosarcoma Cells and Fibroblasts After X-Ray, Proton, Iron Ion and Carbon Ion Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Wakatsuki, Masaru, E-mail: wa@mbe.nifty.com [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Department of Radiation Oncology, Massachusetts General Hospital/Harvard Medical School, Boston, Massachusetts (United States); Magpayo, Nicole; Kawamura, Hidemasa; Held, Kathryn D. [Department of Radiation Oncology, Massachusetts General Hospital/Harvard Medical School, Boston, Massachusetts (United States)

    2012-09-01

    Purpose: Chondrosarcoma is well known as a radioresistant tumor, but the mechanisms underlying that resistance are still unclear. The bystander effect is well documented in the field of radiation biology. We investigated the bystander response induced by X-rays, protons, carbon ions, and iron ions in chondrosarcoma cells using a transwell insert co-culture system that precludes physical contact between targeted and bystander cells. Methods and Materials: Human chondrosarcoma cells were irradiated with 0.1-, 0.5-, 1-, and 2-Gy X-rays, protons, carbon ions or iron ions using a transwell insert co-culture system. Formation of micronuclei and p53 binding protein 1 staining in bystander and irradiated cells were analyzed and bystander signaling between mixed cultures of chondrosarcoma cells, and normal human skin fibroblasts was investigated. Results: In this study, we show that the fraction of cells with DNA damages in irradiated chondrosarcoma cells showed dose-dependent increases with all beams. However, the fraction of cells with DNA damages in all bystander chondrosarcoma cells did not show any change from the levels in control cells. In the bystander signaling between mixed cultures of chondrosarcoma cells and fibroblasts, the amount of micronucleus formation in all bystander chondrosarcoma cells co-cultured with irradiated fibroblasts were the same as the levels for control cells. However, all bystander fibroblasts co-cultured with irradiated chondrosarcoma cells showed significant increases in the fraction of micronucleated cells compared to the rate of control cells. Conclusions: We conclude that chondrosarcoma cells in the transwell insert co-culture system could release bystander stimulations but could not develop bystander responses.

  20. Differential Bystander Signaling Between Radioresistant Chondrosarcoma Cells and Fibroblasts After X-Ray, Proton, Iron Ion and Carbon Ion Exposures

    International Nuclear Information System (INIS)

    Wakatsuki, Masaru; Magpayo, Nicole; Kawamura, Hidemasa; Held, Kathryn D.

    2012-01-01

    Purpose: Chondrosarcoma is well known as a radioresistant tumor, but the mechanisms underlying that resistance are still unclear. The bystander effect is well documented in the field of radiation biology. We investigated the bystander response induced by X-rays, protons, carbon ions, and iron ions in chondrosarcoma cells using a transwell insert co-culture system that precludes physical contact between targeted and bystander cells. Methods and Materials: Human chondrosarcoma cells were irradiated with 0.1-, 0.5-, 1-, and 2-Gy X-rays, protons, carbon ions or iron ions using a transwell insert co-culture system. Formation of micronuclei and p53 binding protein 1 staining in bystander and irradiated cells were analyzed and bystander signaling between mixed cultures of chondrosarcoma cells, and normal human skin fibroblasts was investigated. Results: In this study, we show that the fraction of cells with DNA damages in irradiated chondrosarcoma cells showed dose-dependent increases with all beams. However, the fraction of cells with DNA damages in all bystander chondrosarcoma cells did not show any change from the levels in control cells. In the bystander signaling between mixed cultures of chondrosarcoma cells and fibroblasts, the amount of micronucleus formation in all bystander chondrosarcoma cells co-cultured with irradiated fibroblasts were the same as the levels for control cells. However, all bystander fibroblasts co-cultured with irradiated chondrosarcoma cells showed significant increases in the fraction of micronucleated cells compared to the rate of control cells. Conclusions: We conclude that chondrosarcoma cells in the transwell insert co-culture system could release bystander stimulations but could not develop bystander responses.

  1. Long-term effects of prenatal exposure to low levels of gamma rays on open-field activity in male mice

    International Nuclear Information System (INIS)

    Minamisawa, Takeru; Hirokaga, Kouichi

    1995-01-01

    The open-field activity of first-generation (F 1 ) hybrid male C57BL/6 x C3H mice irradiated with γ rays on day 14 of gestation was studied at the following ages: 6-7 months (young), 12-13 months (adult) and 19-20 months (old). Doses were 0.5 Gy or 1.0 Gy. Open-field activity was recorded with a camera. The camera output signal was recorded every second through an A/D converter to a personal computer. The field was divided into 25 8-cm 2 units. All recordings were continuous for 60 min. The walking speed of the 1.0-Gy group recorded at 19-20 months was higher than that for the comparably aged control group. The time which the irradiated group, recorded at 19-20 months, spent in the corner fields was high in comparison with the control group at the same age. Conversely, the time spent by the irradiated group in the middle fields when recorded at 19-20 months was shorter than in the comparably aged control group. No effect of radiation was shown for any of the behaviors observed and recorded at 6-7 and 12-13 months. The results demonstrate that such exposure to γ rays on day 14 of gestation results in behavioral changes which occur at 19-20 but not at 6-7 or 12-13 months. 10 refs. 2 figs., 1 tab

  2. Long-term effects of prenatal exposure to low levels of gamma rays on open-field activity in male mice.

    Science.gov (United States)

    Minamisawa, T; Hirokaga, K

    1995-11-01

    The open-field activity of first-generation (F1) hybrid male C57BL/6 x C3H mice irradiated with gamma rays on day 14 of gestation was studied at the following ages: 6-7 months (young), 12-13 months (adult) and 19-20 months (old). Doses were 0.5 Gy or 1.0 Gy. Open-field activity was recorded with a camera. The camera output signal was recorded every second through an A/D converter to a personal computer. The field was divided into 25 8-cm2 units. All recordings were continuous for 60 min. The walking speed of the 1.0-Gy group recorded at 19-20 months was higher than that for the comparably aged control group. The time which the irradiated group, recorded at 19-20 months, spent in the corner fields was high in comparison with the control group at the same age. Conversely, the time spent by the irradiated group in the middle fields when recorded at 19-20 months was shorter than in the comparably aged control group. No effect of radiation was shown for any of the behaviors observed and recorded at 6-7 and 12-13 months. The results demonstrate that such exposure to gamma rays on day 14 of gestation results in behavioral changes which occur at 19-20 months but not at 6-7 or 12-13 months.

  3. Study of optimal X-ray exposure conditions in consideration of bone mineral density. Relation between bone mineral density and image contrast

    International Nuclear Information System (INIS)

    Kondo, Yuji

    2003-01-01

    Bone mineral density (BMD) increases through infancy and adolescence, reaching a maximum at 20-30 years of age. Thereafter, BMD gradually decreases with age in both sexes. The image contrast of radiographs of bones varies with the change in BMD owing to the changes in the X-ray absorption of bone. The image contrast of bone generally is higher in the young adult than in the older adult. To examine the relation between BMD and image visibility, we carried out the following experiments. We measured the image contrast of radiographs of a lumbar vertebra phantom in which BMD was equivalent to the average BMD for each developmental period. We examined image visibility at various levels of imaging contrast using the Howlett chart. The results indicated that differences in BMD affect the image contrast of radiographs, and, consequently, image visibility. It was also found that image visibility in the young adult was higher than that in the older adult. The findings showed that, in digital radiography of young adults with high BMD, X-ray exposure can be decreased according the ratio of improvement in image visibility. (author)

  4. Analgesia induced by repeated exposure to low dose X-rays in mice, and involvement of the accessory olfactory system in modulation of the radiation effects

    International Nuclear Information System (INIS)

    Miyachi, Yukihisa; Yamada, Takeshi

    1997-01-01

    The effects of low-dose X-rays on mouse nociceptive behavior were examined using a formalin injected test which rated the amount of time the animals spent licking the injected hind-paw. Male ICR White Swiss mice showed a marked suppression of licking behavior after repeated low-dose X-irradiation (5 cGy/day, 6 consecutive days). The most profound effect was observed on the day 30 after irradiation. The decline of licking behavior, however, was not observed at all following olfactory bulbectomy or vomeronasal tract cut. The analgesic effects could be observed in writhing animals administered acetic-acid intraperitoneally. Moreover, analgesia was totally blocked by the administration of N-nitro-L-arginine, a nitric oxide synthase inhibitor, to accessory olfactory bulbs prior to the exposure. The present results indicate that the olfactory system plays an important role in modulation of radiation-induced analgesia, and a possible involvement of nitric oxide in the formation of recognition memory subjected to repeated X-rays. Relatively higher doses (5 cGy x 9 days, 5 cGy x 12 days), however, did not induce such effects, namely, the decline of nociceptive response was limited to the animals irradiated with the smaller dose. (author)

  5. Annual radiation dose in thermoluminescence dating

    International Nuclear Information System (INIS)

    Li Huhou

    1988-01-01

    The annual radiation dose in thermoluminescence dating has been discussed. The autor gives an entirely new concept of the enviromental radiation in the thermoluminescence dating. Methods of annual dose detemination used by author are dating. Methods of annual dose determination used by author are summed up, and the results of different methods are compared. The emanium escapiug of three radioactive decay serieses in nature has been considered, and several determination methods are described. The contribution of cosmic rays for the annual radiation dose has been mentioned

  6. Annual radiation dose in thermoluminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Huhou, Li [Chinese Academy of Social Sciences, Beijing, BJ (China). Inst. of Archaeology

    1988-11-01

    The annual radiation dose in thermoluminescence dating has been discussed. The autor gives an entirely new concept of the enviromental radiation in the thermoluminescence dating. Methods of annual dose detemination used by author are dating. Methods of annual dose determination used by author are summed up, and the results of different methods are compared. The emanium escapiug of three radioactive decay serieses in nature has been considered, and several determination methods are described. The contribution of cosmic rays for the annual radiation dose has been mentioned.

  7. Lethal and teratogenic effects after exposure to X-rays at various times of early murine gestation

    International Nuclear Information System (INIS)

    Mueller, W.U.S.; Streffer, C.

    1990-01-01

    Various well-defined stages during completion of the second meiotic division and early organogenesis of mouse embryos were X-irradiated with doses of 1-4 Gy (100-400 rad). The major risk was prenatal mortality with radiation sensitivity changing markedly with dependence on the developmental stage irradiated; in the case of day 1 even within hours. The surviving fetuses did show a significantly enhanced frequency of malformations on day 19 of gestation (mostly gastroschisis and some exencephalies). This was true for all stages between days 1 and 8; only sensitivity again changed considerably. The radiation doses used in this study are markedly higher than doses that can be expected from radiation diagnostics, but exposure is in a range comparable to doses that can occur in radiation therapy (e.g., Morbus Hodgkin)

  8. Analysis of cell-cycle regulation following exposure of lung-derived cells to γ-rays

    Science.gov (United States)

    Trani, D.; Lucchetti, C.; Cassone, M.; D'Agostino, L.; Caputi, M.; Giordano, A.

    Acute exposure of mammalian cells to ionizing radiation results in a delay of cell-cycle progression and/or augmentation of apoptosis. Following ionizing radiation-induced DNA damage, cell-cycle arrest in the G1- or G2-phase of the cell-cycle prevents or delays DNA replication or mitosis, providing time for the DNA repair machinery to exert its function. Deregulation or failing of cell-cycle checkpoints and/or DNA repair mechanisms may lead normal cells bearing chromosome mutations to acquire neoplastic autonomy, which in turn can trigger the onset of cancer. Existing studies have focused on the impact of p53 status on the radiation response of lung cancer (LC) cell lines in terms of both cell-cycle regulation and apoptosis, while no comparative studies have been performed on the radiation response of lung derived normal and cancerous epithelial cells. To investigate the radiation response in normal and cancerous phenotypes, along with the role and impact of p53 status, and possible correlations with pRb/p105 or other proteins involved in carcinogenesis and cell-cycle regulation, we selected two lung-derived epithelial cell lines, one normal (NL20, p53 wild-type) and one non-small cell lung cancer (NSCLC), H358 (known to be p53-deficient). We compared the levels of γ-induced cell proliferation ability, cell-cycle arrest, apoptotic index, and expression levels of cell-cycle regulating and regulated proteins. The different cell sensitivity, apoptotic response and protein expression profiles resulting from our study for NL20 and H358 cells suggest that still unknown mechanisms involving p53, pRb/p105 and their target molecules might play a pivotal role in determining cell sensitivity and resistance upon exposure to ionizing radiation.

  9. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  10. Effect of an acute exposure of rat testes to gamma rays on germ cells and on Sertoli and Leydig cell functions

    International Nuclear Information System (INIS)

    Pinon-Lataillade, G.; Maas, J.; Viguier-Martinez, M.C.; Touzalin, A.M.; Jegou, B.

    1991-01-01

    Germ cells and Sertoli and Leydig cell functions were studied from 7 to 180 days after an acute exposure of 2-month-old rat testes to 9 Gy of γ rays. Body weight, testis and epididymal weights were recorded. Sertoli cell parameters (androgen-binding protein, ABP, in caput epididymis and plasma follicle stimulating hormone, FSH) and Leydig cell parameters (plasma luteinizing hormone, LH, testosterone and prostate and seminal vesicle weights) were determined together with the number of germ cells and Sertoli cells. Irradiation did not affect body weight but significantly reduced testicular and epididymal weights from day 7 and day 15 post-irradiation respectively. The cells killed by irradiation were mainly spermatogonia and preleptotene spermatocytes engaged in replicating their DNA at the time of exposure, but all spermatocytes seemed damaged as they gave abnormal descendent cells. By day 34, only elongated spermatids remained in a few tubules and thereafter very little regeneration of the seminiferous epithelium occurred, except for one rat which showed a better regeneration. Levels of ABP decreased by day 15 when the germ cell depletion had reached the pachytene spermatocytes, whereas FSH and LH levels rose when the number of elongated spermatids decreased. Levels of testosterone and the weight of the seminal vesicles did not change; occasionally, the prostate weight was slightly reduced. These results support our hypothesis that pachytene spermatocytes and elongated spermatids are involved in influencing some aspects of Sertoli cell function in the adult rat

  11. Evidence for differences in the thermal histories of Antarctic and non-Antarctic H chondrites with cosmic-ray exposure ages less than 20 Ma

    Science.gov (United States)

    Sears, Derek W. G.; Benoit, Paul; Batchelor, J. David

    1991-01-01

    Antarctic H chondrites show a different range of induced thermoluminescence properties compared with those of H chondrites that have fallen elsewhere in the world. Recent noble gas data of Schultz et al. (1991) show that this difference is displayed most dramatically by meteorites with cosmic-ray exposure ages less than 20 Ma, and they confirm that the differences cannot be attributed to weathering or to the presence of a great many fragments of an unusual Antarctic meteorite. Annealing experiments on an H5 chondrite, and other measurements on a variety of ordinary chondrites, have shown that induced TL properties are sensitive to the thermal histories of the meteorities. It is concluded that the events(s) that released the less than 20 Ma samples, which are predominantly those with exposure ages of 8 + or - 2 Ma, produced two groups with different thermal histories, one that came to earth several 100,000 years ago and that are currently only found in Antarctica, and one that is currently falling on the earth.

  12. S K Date

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. S K Date. Articles written in Bulletin of Materials Science. Volume 23 Issue 2 April 2000 pp 97-101 Magnetic Materials. Comparison of the irreversible thermomagnetic behaviour of some ferro- and ferrimagnetic systems · P S Anil Kumar P A Joy S K Date · More Details Abstract ...

  13. Second Quaternary dating workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    The second Quaternary dating methods workshop was held at Lucas Heights and sponsored by ANSTO and AINSE. Topics covered include, isotope and thermoluminescence dating, usage of accelerator and thermal ionisation mass spectrometry in environmental studies emphasizing on the methodologies used and sample preparation

  14. Dating of cremated bones

    NARCIS (Netherlands)

    Lanting, JN; Aerts-Bijma, AT; van der Plicht, J; Boaretto, E.; Carmi, I.

    2001-01-01

    When dating unburnt bone, bone collagen, the organic fraction of the bone, is used. Collagen does not survive the heat of the cremation pyre, so dating of cremated bone has been considered impossible. Structural carbonate in the mineral fraction of the bone, however, survives the cremation process.

  15. Second Quaternary dating workshop

    International Nuclear Information System (INIS)

    1999-01-01

    The second Quaternary dating methods workshop was held at Lucas Heights and sponsored by ANSTO and AINSE. Topics covered include, isotope and thermoluminescence dating, usage of accelerator and thermal ionisation mass spectrometry in environmental studies emphasizing on the methodologies used and sample preparation

  16. Quaternary dating methods

    International Nuclear Information System (INIS)

    Mahaney, W.C.

    1984-01-01

    The papers in this book cover absolute, relative and multiple dating methods, and have been written by specialists from a number of different earth sciences disciplines - their common interest being the dating of geological materials within the Quaternary. Papers on absolute dating methods discuss radiocarbon, uranium-series, potassium argon, 40 Ar/ 39 Ar, paleomagnetic, obsidian hydration, thermoluminescence, amino acid racemization, tree rings, and lichenometric techniques. Those on relative dating include discussions on various geomorphic relative age indicators such as drainage density changes, hypsometric integrals, bifurcation ratios, stream junction angles, spur morphology, hillslope geometry, and till sheet characteristics. The papers on multiple dating cite examples from the Rocky Mountains, Australia, Lake Agassiz Basin, and the Southern Andes. Also included is the panel discussion which reviews and assesses the information presented, and a field trip guide which discusses the sequences of Wisconian tills and interlayered lacustrine and fluvial sediments. (orig.)

  17. DNA damage and biological expression of adenovirus: A comparison of liquid versus frozen conditions of exposure to gamma rays

    International Nuclear Information System (INIS)

    Bennett, C.B.; Rainbow, A.J.

    1989-01-01

    Human adenovirus type 2 (Ad 2) was irradiated with 137Cs gamma rays in the liquid state at 0 degree C. DNA breaks were correlated with the inactivation of several viral functions and compared to results obtained previously for irradiation of Ad 2 under frozen conditions at -75 degrees C. Irradiation at 0 degree C induced 170 +/- 20 single-strand breaks and 2.6 +/- 0.4 double-strand breaks/Gy/10(12) Da in the viral DNA. Viral adsorption to human KB cells was inactivated with a D0 of 9.72 +/- 1.18 kGy, whereas the inactivation of Ad 2 plaque formation had a D0 of 0.99 +/- 0.14 or 1.1 +/- 0.29 kGy when corrected for the effect of radiation on virus adsorption. For the adsorbed virus, an average of 4.3 +/- 1.7 single-strand and 0.065 +/- 0.02 double-strand breaks were induced in the viral DNA per lethal hit. In contrast, irradiation of Ad 2 at -75 degrees C results in 2.6- to 3.4-fold less DNA breakage per Gy and a 5.6-fold increase in D0 for plaque formation of the adsorbed virus. Furthermore, although host cell reactivation (HCR) of Ad 2 viral structural antigen production for irradiated virus was substantially reduced in the xeroderma pigmentosum fibroblast strain (XP25RO) compared to normal strains for irradiation at -75 degrees C (57% HCR), it was only slightly reduced compared to normal for irradiation at 0 degree C (88% HCR). These results indicate that the spectrum of DNA damage is both quantitatively and qualitatively different for the two conditions of irradiation

  18. Induction and disappearance of γH2AX foci and formation of micronuclei after exposure of human lymphocytes to ⁶⁰Co γ-rays and p(66)+ Be(40) neutrons.

    Science.gov (United States)

    Vandersickel, Veerle; Beukes, Philip; Van Bockstaele, Bram; Depuydt, Julie; Vral, Anne; Slabbert, Jacobus

    2014-02-01

    To investigate both the formation of micronuclei (MN) and the induction and subsequent loss of phosphorylated histone H2AX foci (γH2AX foci) after in vitro exposure of human lymphocytes to either (60)Co γ-rays or p(66)+ Be(40) neutrons. MN dose response (DR) curves were obtained by exposing isolated lymphocytes of 10 different donors to doses ranging from 0-4 Gy γ-rays or 0-2 Gy neutrons. Also, γH2AX foci DR curves were obtained following exposure to doses ranging from 0-0.5 Gy of either γ-rays or neutrons. Foci kinetics for lymphocytes for a single donor exposed to 0.5 Gy γ-rays or neutrons were studied up to 24 hours post-irradiation. Micronuclei yields following neutron exposure were consistently higher compared to that from (60)Co γ-rays. All MN yields were over-dispersed compared to a Poisson distribution. Over-dispersion was higher after neutron irradiation for all doses > 0.1 Gy. Up to 4 hours post-irradiation lower yields of neutron-induced γH2AX foci were observed. Between 4 and 24 hours the numbers of foci from neutrons were consistently higher than that from γ-rays. The half-live of foci disappearance is only marginally longer for neutrons compared to that from γ-rays. Foci formations were more likely to be over-dispersed for neutron irradiations. Although neutrons are more effective to induce MN, the absolute number of induced γH2AX foci are less at first compared to γ-rays. With time neutron-induced foci are more persistent. These findings are helpful for using γH2AX foci in biodosimetry and to understand the repair of neutron-induced cellular damage.

  19. Date Rape (For Teens)

    Science.gov (United States)

    ... owe" someone sex, even if you're a couple. Rape is not always violent. If you say " ... date rape" drugs like: rohypnol , called roofies, lunch money, or mind erasers GHB (gamma hydroxybutyric acid), called ...

  20. Methods of dating

    Energy Technology Data Exchange (ETDEWEB)

    Gatty, B

    1986-04-01

    Scientific methods of dating, born less than thirty years ago, have recently improved tremendously. First the dating principles will be given; then it will be explained how, through natural radioactivity, we can have access to the age of an event or an object; the case of radiocarbon will be especially emphasized. The principle of relative methods such as thermoluminescence or paleomagnetism will also be shortly given. What is the use for dating. The fields of its application are numerous; through these methods, relatively precise ages can be given to the major events which have been keys in the history of universe, life and man; thus, dating is a useful scientific tool in astrophysics, geology, biology, anthropology and archeology. Even if certain ages are still subject to controversies, we can say that these methods have confirmed evolution's continuity, be it on a cosmic, biologic or human scale, where ages are measured in billions, millions or thousands of years respectively.

  1. Radiometric dating methods

    International Nuclear Information System (INIS)

    Bourdon, B.

    2003-01-01

    The general principle of isotope dating methods is based on the presence of radioactive isotopes in the geologic or archaeological object to be dated. The decay with time of these isotopes is used to determine the 'zero' time corresponding to the event to be dated. This paper recalls the general principle of isotope dating methods (bases, analytical methods, validation of results and uncertainties) and presents the methods based on natural radioactivity (Rb-Sr, Sm-Nd, U-Pb, Re-Os, K-Ar (Ar-Ar), U-Th-Ra- 210 Pb, U-Pa, 14 C, 36 Cl, 10 Be) and the methods based on artificial radioactivity with their applications. Finally, the methods based on irradiation damages (thermoluminescence, fission tracks, electron spin resonance) are briefly evoked. (J.S.)

  2. NAIP 2012 Image Dates

    Data.gov (United States)

    Farm Service Agency, Department of Agriculture — This map is produced by the Aerial Phtography Field Office (APFO) to show the image acquisition dates for the 2012 National Agriculture Imagery Program (NAIP)...

  3. NAIP 2014 Image Dates

    Data.gov (United States)

    Farm Service Agency, Department of Agriculture — This map is produced by the Aerial Phtography Field Office (APFO) to show the image acquisition dates for the 2014 National Agriculture Imagery Program (NAIP)...

  4. Food Product Dating

    Science.gov (United States)

    ... Standard Forms FSIS United States Department of Agriculture Food Safety and Inspection Service About FSIS District Offices ... Web Content Viewer (JSR 286) Actions ${title} Loading... Food Product Dating "Best if Used By" is a ...

  5. NAIP 2013 Image Dates

    Data.gov (United States)

    Farm Service Agency, Department of Agriculture — This map is produced by the Aerial Phtography Field Office (APFO) to show the image acquisition dates for the 2013 National Agriculture Imagery Program (NAIP)...

  6. NAIP 2011 Image Dates

    Data.gov (United States)

    Farm Service Agency, Department of Agriculture — This map is produced by the Aerial Phtography Field Office (APFO) to show the image acquisition dates for the 2011 National Agriculture Imagery Program (NAIP)...

  7. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel

  8. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel.

  9. Dating fossil opal phytoliths

    International Nuclear Information System (INIS)

    Lentfer, C.; Boyd, B.; Torrence, R.

    1999-01-01

    Full text: Opal phytoliths are microscopic silica bodies formed by the precipitation of hydrated silica dioxide (SiO 2 nH 2 0) in, around and between cell walls. They are relatively resistant to degradation in most environments and thus, can occur in large quantities in palaeosediments. Consequently, they are valuable tools for environmental reconstruction. Furthermore, phytoliths are often the only recoverable organic material in well oxidised sediments, the occluded carbon provides the opportunity for dating sediment whose ages have previously been difficult to determine, and thus, increase the potential for fine resolution determination of environmental change. This poster describes the results of an investigation assessing the viability of AMS radiocarbon dating of fossil phytolith inclusions using samples from Garua Island, West New Britain, PNG. Thirteen phytolith samples, isolated from sediments previously dated using tephrastratigraphy and C14 dating of macroremains of nutshells and wood charcoal, were used in the analysis. As a control measure, thirteen parallel samples of microscopic charcoal were also dated using AMS. The results show that the AMS dates for the microscopic charcoal samples are consistent with ages anticipated from the other dating methods, for all but one sample. However, the dates for eight of the thirteen phytolith samples are considerably younger than expected. This bias could be explained by several factors, including downwashing of phytolith through soils, bioturbation, carbon exchange through the siliceous matrix of the phytolith bodies, and contamination from extraneous sources of modern carbon retained in the samples. Research is currently focusing on the investigation of these issues and selected samples are in the process of being retreated with strong oxidising agents to clear contaminants prior to re-dating. Further to this, a full investigation of one profile with a long sequence is underway. High concentrations of

  10. Duodenal crypt health following exposure to Cr(VI): Micronucleus scoring, γ-H2AX immunostaining, and synchrotron X-ray fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Chad M.; Wolf, Jeffrey C.; Elbekai, Reem H.; Paranjpe, Madhav G.; Seiter, Jennifer M.; Chappell, Mark A.; Tappero, Ryan V.; Suh, Mina; Proctor, Deborah M.; Bichteler, Anne; Haws, Laurie C.; Harris, Mark A.

    2015-08-01

    Lifetime exposure to high concentrations of hexavalent chromium [Cr(VI)] in drinking water results in intestinal damage and an increase in duodenal tumors in B6C3F1 mice. To assess whether these tumors could be the result of a direct mutagenic or genotoxic mode of action, we conducted a GLP-compliant 7-day drinking water study to assess crypt health along the entire length of the duodenum. Mice were exposed to water (vehicle control), 1.4, 21, or 180 ppm Cr(VI) via drinking water for 7 consecutive days. Crypt enterocytes in Swiss roll sections were scored as normal, mitotic, apoptotic, karyorrhectic, or as having micronuclei. A single oral gavage of 50 mg/kg cyclophosphamide served as a positive control for micronucleus induction. Exposure to 21 and 180 ppm Cr(VI) significantly increased the number of crypt enterocytes. Micronuclei and γ-H2AX immunostaining were not elevated in the crypts of Cr(VI)-treated mice. In contrast, treatment with cyclophosphamide significantly increased numbers of crypt micronuclei and qualitatively increased γ-H2AX immunostaining. Synchrotron-based X-ray fluorescence (XRF) microscopy revealed the presence of strong Cr fluorescence in duodenal villi, but negligible Cr fluorescence in the crypt compartment. Together, these data indicate that Cr(VI) does not adversely effect the crypt compartment where intestinal stem cells reside, and provide additional evidence that the mode of action for Cr(VI)-induced intestinal cancer in B6C3F1 mice involves chronic villous wounding resulting in compensatory crypt enterocyte hyperplasia.

  11. History of radiocarbon dating

    Energy Technology Data Exchange (ETDEWEB)

    Libby, W F [Department of Chemistry and Institute of Geophysics, University of California, Los Angeles, CA (United States)

    1967-08-15

    The development is traced of radiocarbon dating from its birth in curiosity regarding the effects of cosmic radiation on Earth. Discussed in historical perspective are: the significance of the initial measurements in determining the course of developments; the advent of the low-level counting technique; attempts to avoid low-level counting by the use of isotopic enrichment; the gradual appearance of the environmental effect due to the combustion of fossil fuel (Suess effect); recognition of the atmosphere ocean barrier for carbon dioxide exchange; detailed understanding of the mixing mechanism from the study of fallout radiocarbon; determination of the new half-life; indexing and the assimilation problem for the massive accumulation of dates; and the proliferation of measurement techniques and the impact of archaeological insight on the validity of radiocarbon dates. (author)

  12. Confronting Dating Violence.

    Science.gov (United States)

    McNulty, Raymond J.; Heller, Daniel A.; Binet, Tracy

    1997-01-01

    To be safe havens for children, schools cannot address the intellect only. Brattleboro (Vermont) Union High School went beyond academics by sponsoring a performance of "The Yellow Dress," a powerful one-woman play about a teenage victim of dating violence. The production challenged participants to unite school and community, intellect…

  13. The Realities of Date Rape.

    Science.gov (United States)

    Presley, Cara; Watson, Jennifer; Williams, Audrey R.

    This poster presentation addresses the issue of date rape, specifically in the college environment. Highlighted are date rape statistics, demographics, and date rape drugs. Also discussed are date rape warnings and prevention strategies. It is concluded that college and university administrators must place the issue of date rape and acquaintance…

  14. Fluvial terrace dating using in situ cosmogenic {sup 21}Ne

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, E. [Univ. of Illinois, Chicago, IL (United States); Caffee, M. [Lawrence Livermore National Lab., CA (United States)

    1994-12-01

    Through the analysis of cosmic-ray produced radio-genic and stable nuclide concentrations, specifically {sup 21}Ne, we hope to date certain geomorphic features located along the tributaries of the Colorado River in the Eastern Grand Canyon and the Rainbow Plateau located in Utah. During the Quaternary, the Colorado River system was fed by glacial melting and run-off from the Wind River and Colorado Mountain Ranges. Past periods of aggradation allowed the emplacement of terrace features from debris flow activity. By dating such features we can further constrain the timing of key events such as river down cutting, terrace genesis/exposure age, and rates of surface erosion. Knowing the age and elevation of each terrace we can determine an average rate of down cutting of this river system. This, in turn, will offer information regarding alpine glaciation which is a sensitive indicator of global climate change. Studying the relative concentrations of these isotopic species in surface rocks can be useful in researching glacial periodicity and the relationship between solar activity and climate.

  15. Reconstruction of local fallout composition and gamma-ray exposure in a village contaminated by the first USSR nuclear test in the Semipalatinsk nuclear test site in Kazakhstan.

    Science.gov (United States)

    Imanaka, Tetsuji; Yamamoto, Masayoshi; Kawai, Kenta; Sakaguchi, Aya; Hoshi, Masaharu; Chaizhunusova, Nailya; Apsalikov, Kazbek

    2010-11-01

    After the disintegration of the USSR in end of 1991, it became possible for foreign scientists to visit Kazakhstan, in order to investigate the radiological consequences of nuclear explosions that had been conducted at the Semipalatinsk nuclear test site (SNTS). Since the first visit in 1994, our group has been continuing expeditions for soil sampling at various areas around SNTS. The current level of local fallout at SNTS was studied through γ-spectrometry for (137)Cs as well as α-spectrometry for (239,240)Pu. Average values of soil inventory from wide areas around SNTS were 3,500 and 3,700 Bq m(-2) for (137)Cs and (239,240)Pu, respectively, as of January 1, 2000. The average level of (137)Cs is comparable to that in Japan due to global fallout, while the level of (239,240)Pu is several tens of times larger than that in Japan. Areas of strong contamination were found along the trajectories of radioactive fallout, information on which was declassified after the collapse of the USSR. Our recent efforts of soil sampling were concentrated on the area around the Dolon village heavily affected by the radioactive plume from the first USSR atomic bomb test in 1949 and located 110 km east from ground zero of the explosion. Using soil inventory data, retrospective dosimetry was attempted by reconstructing γ-ray exposure from fission product nuclides deposited on the ground. Adopting representative parameters for the initial (137)Cs deposition (13 kBq m(-2)), the refractory/volatile deposition ratio (3.8) and the plume arrival time after explosion (2.5 h), an absorbed dose in air of 600 mGy was obtained for the 1-year cumulative dose in Dolon village, due to the first bomb test in 1949. Considering possible ranges of the parameters, 350 and 910 mGy were estimated for high and low cases of γ-ray dose in air, respectively. It was encouraging that the deduced value was consistent with other estimations using thermal luminescence and archived monitoring data. The present

  16. Room-temperature X-ray diffraction studies of cisplatin and carboplatin binding to His15 of HEWL after prolonged chemical exposure

    International Nuclear Information System (INIS)

    Tanley, Simon W. M.; Schreurs, Antoine M. M.; Kroon-Batenburg, Loes M. J.; Helliwell, John R.

    2012-01-01

    Binding of cisplatin to His15 in hen egg-white lysozyme in aqueous media is observed after prolonged chemical exposure for 15 months, in contrast to the lack of binding that was observed after 4 d in a previous study. Binding of carboplatin is seen in greater detail in the case of room-temperature data collection compared with cryo data collection. The anticancer complexes cisplatin and carboplatin are known to bind to both the N δ and the N ∊ atoms of His15 of hen egg-white lysozyme (HEWL) in the presence of dimethyl sulfoxide (DMSO). However, neither binds in aqueous media after 4 d of crystallization and crystal growth, suggesting that DMSO facilitates cisplatin/carboplatin binding to the N atoms of His15 by an unknown mechanism. Crystals of HEWL cocrystallized with cisplatin in both aqueous and DMSO media, of HEWL cocrystallized with carboplatin in DMSO medium and of HEWL cocrystallized with cisplatin and N-acetylglucosamine (NAG) in DMSO medium were stored for between seven and 15 months. X-ray diffraction studies of these crystals were carried out on a Bruker APEX II home-source diffractometer at room temperature. Room-temperature X-ray diffraction data collection removed the need for cryoprotectants to be used, ruling out any effect that the cryoprotectants might have had on binding to the protein. Both cisplatin and carboplatin still bind to both the N δ and N ∊ atoms of His15 in DMSO media as expected, but more detail for the cyclobutanedicarboxylate (CBDC) moiety of carboplatin was observed at the N ∊ binding site. However, two molecules of cisplatin were now observed to be bound to His15 in aqueous conditions. The platinum peak positions were identified using anomalous difference electron-density maps as a cross-check with F o − F c OMIT electron-density maps. The occupancies of each binding site were calculated using SHELXTL. These results show that over time cisplatin binds to both N atoms of His15 of HEWL in aqueous media, whereas this

  17. Nordic working group on x-ray diagnostics - Practical implementation of the directive on medical exposures in the Nordic EU countries

    Energy Technology Data Exchange (ETDEWEB)

    Waltenburg, H.N.; Groen, P. [National Institute of Radiation Hygiene, Herlev (Denmark); Leitz, W. [Swedish Radiation Protection Authority, Stockholm (Sweden); Servomaa, A. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland); Einarsson, G. [Icelandic Radiation Protection Institute, Reykjavik (Iceland); Olerud, H. [Norwegian Radiation Protection Authority, Oslo (Norway)

    2003-06-01

    The EU directive on medical exposure, 97/43/EURATOM (referred to in the following as MED) imposes new requirements on hospital departments using ionising radiation for either diagnostics or treatment of illnesses. The directive was approved on 30 June 1997, and the member states were obliged to implement the requirements into national legislation before 13 May 2000. The implementation of a directive of this kind is a complicated process requiring time as well as other resources. The Nordic EU countries (Sweden, Finland and Denmark) must comply with the rules in MED, while this is not the case for Norway and Iceland as EFTA (European Free Trade Association) members, since the agreements between EFTA and EU does not cover the EURATOM treaty. The issues that have to be addressed in the national legislation are justification, optimisation, responsibilities, procedures, training, equipment, special protection during pregnancy and breast-feeding, and potential exposure. A central aspect in MED is the requirement for quality assurance programmes to be established in radiological departments (and in other departments employing ionising radiation). A change of this magnitude in legislation requires adjustments in the routines of the individual departments. The staff in each department needs to prepare and follow procedures and instructions for daily work and also participate in day-to-day quality assurance. A considerable burden has also been laid on the radiation protection authorities in the member states, first in the process of transposing MED into national law or regulations, and secondly in guiding the process of practical implementation. Here we will describe how the individual Nordic EU countries have chosen to implement MED in national legislation and how far the process of complying with the requirements has come so far. Although Norway and Iceland are not required to follow MED, it is still interesting for comparison to include the situation in these countries

  18. Nordic working group on x-ray diagnostics - Practical implementation of the directive on medical exposures in the Nordic EU countries

    International Nuclear Information System (INIS)

    Waltenburg, H.N.; Groen, P.; Leitz, W.; Servomaa, A.; Einarsson, G.; Olerud, H.

    2003-01-01

    The EU directive on medical exposure, 97/43/EURATOM (referred to in the following as MED) imposes new requirements on hospital departments using ionising radiation for either diagnostics or treatment of illnesses. The directive was approved on 30 June 1997, and the member states were obliged to implement the requirements into national legislation before 13 May 2000. The implementation of a directive of this kind is a complicated process requiring time as well as other resources. The Nordic EU countries (Sweden, Finland and Denmark) must comply with the rules in MED, while this is not the case for Norway and Iceland as EFTA (European Free Trade Association) members, since the agreements between EFTA and EU does not cover the EURATOM treaty. The issues that have to be addressed in the national legislation are justification, optimisation, responsibilities, procedures, training, equipment, special protection during pregnancy and breast-feeding, and potential exposure. A central aspect in MED is the requirement for quality assurance programmes to be established in radiological departments (and in other departments employing ionising radiation). A change of this magnitude in legislation requires adjustments in the routines of the individual departments. The staff in each department needs to prepare and follow procedures and instructions for daily work and also participate in day-to-day quality assurance. A considerable burden has also been laid on the radiation protection authorities in the member states, first in the process of transposing MED into national law or regulations, and secondly in guiding the process of practical implementation. Here we will describe how the individual Nordic EU countries have chosen to implement MED in national legislation and how far the process of complying with the requirements has come so far. Although Norway and Iceland are not required to follow MED, it is still interesting for comparison to include the situation in these countries

  19. Amino acid racemisation dating

    International Nuclear Information System (INIS)

    Murray-Wallace, C.V.

    1999-01-01

    The potential of the time-dependent amino acid racemisation reaction as a method of age assessment was first reported by Hare and Abelson (1968). They noted that in specimens of the bivalve mollusc Mercenaria sp., greater concentrations of amino acids in the D-configuration with increasing fossil age. Hare and Abelson (1968) also reported negligible racemisation in a modern specimen of Mecanaria sp. On this basis they suggested that the extent of amino acid racemisation (epimerisation in the case of isoleucine) may be used to assess the age of materials within and beyond the range of radiocarbon dating. For the past thirty years amino acid racemisation has been extensively applied in Quaternary research as a method of relative and numeric dating, and a particularly large literature has emerged on the subject

  20. Dating fractures in infants

    Energy Technology Data Exchange (ETDEWEB)

    Halliday, K.E., E-mail: kath.halliday@nuh.nhs.uk [Department of Radiology, Nottingham University Hospitals, Queen' s Medical Centre, Nottingham (United Kingdom); Broderick, N J; Somers, J M [Department of Radiology, Nottingham University Hospitals, Queen' s Medical Centre, Nottingham (United Kingdom); Hawkes, R [Department of Radiology, Paul O' Gorman Building, Bristol (United Kingdom)

    2011-11-15

    Aim: To document the timing of the appearance of the radiological features of fracture healing in a group of infants in which the date of injury was known and to assess the degree of interobserver agreement. Materials and methods: Three paediatric radiologists independently assessed 161 images of 37 long bone fractures in 31 patients aged 0-44 months. The following features were assessed: soft-tissue swelling, subperiosteal new bone formation (SPNBF), definition of fracture line, presence or absence of callus, whether callus was well or ill defined, and the presence of endosteal callus. Results: Agreement between observers was only moderate for all discriminators except SPNBF. SPNBF was invariably seen after 11 days but was uncommon before this time even in the very young. In one case SPNBF was seen at 4 days. Conclusion: With the exception of SPNBF, the criteria relied on to date fractures are either not reproducible or are poor discriminators of fracture age.

  1. Dating fractures in infants

    International Nuclear Information System (INIS)

    Halliday, K.E.; Broderick, N.J.; Somers, J.M.; Hawkes, R.

    2011-01-01

    Aim: To document the timing of the appearance of the radiological features of fracture healing in a group of infants in which the date of injury was known and to assess the degree of interobserver agreement. Materials and methods: Three paediatric radiologists independently assessed 161 images of 37 long bone fractures in 31 patients aged 0-44 months. The following features were assessed: soft-tissue swelling, subperiosteal new bone formation (SPNBF), definition of fracture line, presence or absence of callus, whether callus was well or ill defined, and the presence of endosteal callus. Results: Agreement between observers was only moderate for all discriminators except SPNBF. SPNBF was invariably seen after 11 days but was uncommon before this time even in the very young. In one case SPNBF was seen at 4 days. Conclusion: With the exception of SPNBF, the criteria relied on to date fractures are either not reproducible or are poor discriminators of fracture age.

  2. Thermoluminescence dating method

    International Nuclear Information System (INIS)

    Zink, A.

    2004-01-01

    A crystal that is submitted to radiation stores energy and releases this energy under the form of light whenever it is heated. These 2 properties: the ability to store energy and the ability to reset the energy stored are the pillars on which time dating methods like thermoluminescence are based. A typical accuracy of the thermoluminescence method is between 5 to 7% but an accuracy of 3% can be reached with a sufficient number of measurement. This article describes the application of thermoluminescence to the dating of a series of old terra-cotta statues. This time measurement is absolute and does not require any calibration, it represents the time elapsed since the last heating of the artifact. (A.C.)

  3. Radiocarbon dating for contributors

    International Nuclear Information System (INIS)

    Jansen, H.S.

    1984-06-01

    This report describes the radiocarbon facility at the Institute of Nuclear Sciences, and is written for potential contributors, current users, and for those who advise others. The report briefly outlines the principles and practices of C-14 dating; with emphasis on factors that enable contributors to judge whether C-14 work is appropriate, and to assist them with the procedures to be followed in order to get the best results. Age determinations, being the main requirements by contributors, have been discussed in detail

  4. An innovative in vitro device providing continuous low doses of γ-rays mimicking exposure to the space environment: A dosimetric study

    Science.gov (United States)

    Pereda-Loth, V.; Franceries, X.; Afonso, A. S.; Ayala, A.; Eche, B.; Ginibrière, D.; Gauquelin-Koch, G.; Bardiès, M.; Lacoste-Collin, L.; Courtade-Saïdi, M.

    2018-02-01

    Astronauts are exposed to microgravity and chronic irradiation but experimental conditions combining these two factors are difficult to reproduce on earth. We have created an experimental device able to combine chronic irradiation and altered gravity that may be used for cell cultures or plant models in a ground based facility. Irradiation was provided by thorium nitrate powder, conditioned so as to constitute a sealed source that could be placed in an incubator. Cell plates or plant seedlings could be placed in direct contact with the source or at various distances above it. Moreover, a random positioning machine (RPM) could be positioned on the source to simulate microgravity. The activity of the source was established using the Bateman formula. The spectrum of the source, calculated according to the natural decrease of radioactivity and the gamma spectrometry, showed very good adequacy. The experimental fluence was close to the theoretical fluence evaluation, attesting its uniform distribution. A Monte Carlo model of the irradiation device was processed by GATE code. Dosimetry was performed with radiophotoluminescent dosimeters exposed for one month at different locations (x and y axes) in various cell culture conditions. Using the RPM placed on the source, we reached a mean absorbed dose of gamma rays of (0.33 ± 0.17) mSv per day. In conclusion, we have elaborated an innovative device allowing chronic radiation exposure to be combined with altered gravity. Given the limited access to the International Space Station, this device could be useful to researchers interested in the field of space biology.

  5. Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations

    Energy Technology Data Exchange (ETDEWEB)

    Neroladaki, Angeliki; Botsikas, Diomidis; Boudabbous, Sana; Becker, Christoph D.; Montet, Xavier [Geneva University Hospital, Department of Radiology, Geneva 4 (Switzerland)

    2013-02-15

    The purpose of this study was to assess the diagnostic image quality of ultra-low-dose chest computed tomography (ULD-CT) obtained with a radiation dose comparable to chest radiography and reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard dose diagnostic CT (SDD-CT) or low-dose diagnostic CT (LDD-CT) reconstructed with FBP alone. Unenhanced chest CT images of 42 patients acquired with ULD-CT were compared with images obtained with SDD-CT or LDD-CT in the same examination. Noise measurements and image quality, based on conspicuity of chest lesions on all CT data sets were assessed on a five-point scale. The radiation dose of ULD-CT was 0.16 {+-} 0.006 mSv compared with 11.2 {+-} 2.7 mSv for SDD-CT (P < 0.0001) and 2.7 {+-} 0.9 mSv for LDD-CT. Image quality of ULD-CT increased significantly when using MBIR compared with FBP or ASIR (P < 0.001). ULD-CT reconstructed with MBIR enabled to detect as many non-calcified pulmonary nodules as seen on SDD-CT or LDD-CT. However, image quality of ULD-CT was clearly inferior for characterisation of ground glass opacities or emphysema. Model-based iterative reconstruction allows detection of pulmonary nodules with ULD-CT with radiation exposure in the range of a posterior to anterior (PA) and lateral chest X-ray. (orig.)

  6. Sediment dating in review

    International Nuclear Information System (INIS)

    Prescott, J.R.; Robertson, G.B.

    1997-01-01

    The paper will comment on a few issues of particular relevance to Australasia. Thermoluminescent (TL) methods applied to open sites have been demonstrated to be effective. A particularly good example of this is to be found in the South East of South Australia, where a sequence of low ranges runs roughly parallel with the coast. They represent relict sand dunes left behind, on a slowly rising land surface by successive interglacial incursions of the sea at roughly 120 ka intervals. Comparison with ages established on independent geological grounds allows a test of quartz TL and IRSL ages that is believable back to 500 ka. Older than this, we do not yet understand the physics of the quartz well enough to go unequivocally forward (backward?). Similar results are emerging elsewhere. With dating limits being pushed ever further back, the time variation of the environmental radiation giving rise to the stored luminescent energy needs to be addressed. Particularly at wet sites, radioactive disequilibrium must be considered. In any case, a time profile of the radiation dose rate needs to be determined.In dating a given site or sites the value of ages obtained by any dating method,including C-14, is enhanced by parallel measurements with an different method

  7. Exposure to low-dose X-rays promotes peculiar autophagic cell death in Drosophila melanogaster, an effect that can be regulated by the inducible expression of Hml dsRNA

    Energy Technology Data Exchange (ETDEWEB)

    Kanao, Tomoko [Department of Radiological Sciences, International University of Health and Welfare, Kitakanemaru 2600-1, Ohtawara-shi, Tochigi-ken 324-8501 (Japan); Miyachi, Yukihisa [Department of Radiological Sciences, International University of Health and Welfare, Kitakanemaru 2600-1, Ohtawara-shi, Tochigi-ken 324-8501 (Japan)]. E-mail: ymiyachi@iuhw.ac.jp

    2006-03-20

    We previously reported that to induce an early emergence effect with low-dose X-irradiation in Drosophila, exposure during the prepupae stage is necessary. The present study examined the mechanism by which low-dose radiation rapidly eliminates larval cells and activates the formation of the imaginal discs during metamorphosis. Upon exposure to 0.5 Gy X-rays at 2 h after puparium formation (APF), the larval salivary glands swelled and were surrounded by remarkably thick structures containing an acid phosphatase (Acph) enzyme, implicating a peculiar autophagic cell death. TUNEL staining revealed the presence of DNA fragmentations compared with cells from sham controls which remained unchanged until 12 h APF. Additionally, the salivary glands of exposed flies were completely destroyed by 10 h APF. Furthermore, exposure to 0.5 Gy X-rays also facilitated the activity of the engulfment function of dendritic cells (DCs); they were generated in the larval salivary glands, engulfed the cell corpses and finally moved to the fat body. Data from an experiment demonstrating the inducible expression of Hml double-stranded RNA (dsRNA) indicate that a slow rate of engulfment of larval cells results in a longer time to emergence. Thus, the animals subjected to low-dose X-rays activated autophagic processes, resulting in significantly faster adult eclosion.

  8. Exposure to low-dose X-rays promotes peculiar autophagic cell death in Drosophila melanogaster, an effect that can be regulated by the inducible expression of Hml dsRNA

    International Nuclear Information System (INIS)

    Kanao, Tomoko; Miyachi, Yukihisa

    2006-01-01

    We previously reported that to induce an early emergence effect with low-dose X-irradiation in Drosophila, exposure during the prepupae stage is necessary. The present study examined the mechanism by which low-dose radiation rapidly eliminates larval cells and activates the formation of the imaginal discs during metamorphosis. Upon exposure to 0.5 Gy X-rays at 2 h after puparium formation (APF), the larval salivary glands swelled and were surrounded by remarkably thick structures containing an acid phosphatase (Acph) enzyme, implicating a peculiar autophagic cell death. TUNEL staining revealed the presence of DNA fragmentations compared with cells from sham controls which remained unchanged until 12 h APF. Additionally, the salivary glands of exposed flies were completely destroyed by 10 h APF. Furthermore, exposure to 0.5 Gy X-rays also facilitated the activity of the engulfment function of dendritic cells (DCs); they were generated in the larval salivary glands, engulfed the cell corpses and finally moved to the fat body. Data from an experiment demonstrating the inducible expression of Hml double-stranded RNA (dsRNA) indicate that a slow rate of engulfment of larval cells results in a longer time to emergence. Thus, the animals subjected to low-dose X-rays activated autophagic processes, resulting in significantly faster adult eclosion

  9. Comparison of gestational dating methods and implications ...

    Science.gov (United States)

    OBJECTIVES: Estimating gestational age is usually based on date of last menstrual period (LMP) or clinical estimation (CE); both approaches introduce potential bias. Differences in methods of estimation may lead to misclassificat ion and inconsistencies in risk estimates, particularly if exposure assignment is also gestation-dependent. This paper examines a'what-if' scenario in which alternative methods are used and attempts to elucidate how method choice affects observed results.METHODS: We constructed two 20-week gestational age cohorts of pregnancies between 2000 and 2005 (New Jersey, Pennsylvania, Ohio, USA) using live birth certificates : one defined preterm birth (PTB) status using CE and one using LMP. Within these, we estimated risk for 4 categories of preterm birth (PTBs per 106 pregnancies) and risk differences (RD (95% Cl s)) associated with exposure to particulate matter (PM2. 5).RESULTS: More births were classified preterm using LMP (16%) compared with CE (8%). RD divergences increased between cohorts as exposure period approached delivery. Among births between 28 and 31 weeks, week 7 PM2.5 exposure conveyed RDs of 44 (21 to 67) for CE and 50 (18 to 82) for LMP populations, while week 24 exposure conveyed RDs of 33 (11 to 56) and -20 (-50 to 10), respectively.CONCLUSIONS: Different results from analyses restricted to births with both CE and LMP are most likely due to differences in dating methods rather than selection issues. Results are sensitive t

  10. Development of a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value; Erarbeitung eines Konzepts zur Ermittlung der Strahlenexposition von Patienten bei zahnmedizinischen Roentgenuntersuchungen und Erhebung von statistischen Daten zur Erstellung diagnostischer Referenzwerten

    Energy Technology Data Exchange (ETDEWEB)

    Kueppers, C.; Sering, M. [Oekoinstitut Freiburg e.V., Freiburg (Germany); Poppe, B.; Poplawski, A.; Looe, H.K.; Beyer, D.; Pfaffenberger, A.; Chofor, N.; Eenboom, F. [Pius Hospital, Oldenburg (Germany)

    2012-02-15

    The research project on the development a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value includes the following issues: Fundamental facts: dental X-ray examination techniques, dose relevant factors and characteristics during X-ray examinations, radiation exposed organs during dental X-ray examinations, dose assessment based on phantoms. Materials and methodologies of the project: TLD measurements using the phantom, calculation of the effective dose during dental X-ray examinations, properties and settings of the reference facilities for the determination of radiation exposure, selection of dental offices, dosimetric measurements, data acquisition and statistical evaluation. Results of dosimetric examinations: results of dosimetric measurements at reference facilities, results of dosimetric measurements in dental offices. Discussion of the concept for the determination of the radiation exposure during dental X-ray examinations.

  11. Dating Violence among College Students

    Science.gov (United States)

    Iconis, Rosemary

    2013-01-01

    Dating violence is a significant problem on college campuses. More than one-fifth of the undergraduate dating population are physically abused by their dating partners and an even greater percentage are psychologically abused. Researchers have identified risk factors for college student dating violence. Preventive interventions are strongly…

  12. Flirting in Online Dating

    DEFF Research Database (Denmark)

    Mortensen, Kristine Køhler

    2017-01-01

    Various fields have examined the activity of flirting, predominantly based on experimental and reported data; the interactional workings are therefore often overlooked. Based on emails and chats from two Danish online dating sites, this article investigates how users negotiate romantic connections...... through the flirting strategy of ‘imagined togetherness’, linguistically constructing imagery of a shared future. Using the notion of the chronotope, turn-by-turn analysis demonstrates how users, embedded in the activity of getting to know each other, tenuously communicate romantic interest by alluding...

  13. Bomb pulse radiocarbon dating

    International Nuclear Information System (INIS)

    Tuniz, C.; Zoppi, U.; Hotchkis, M.A.C.

    2004-01-01

    Modern forensic science has to deal not only with homicides and other traditional crimes but also with more global threats such as the smuggling of nuclear materials, clandestine production of weapons of mass destruction, stockpiling of illicit drugs by state controlled groups and war crimes. Forensic applications have always benefited from the use of advanced analytical tools that can characterize materials found at crime scenes. In this paper we will discuss the use of accelerator mass spectrometry (AMS) as an ultrasensitive tool for the crime laboratories of the third millennium. An important objective in forensic science is to order past events chronologically by analysing materials associated with criminal actions. Radiocarbon dating is known to the general public for its application to historical and prehistorical investigations. Examples of forensic significance include the assassination of the Inca Atahualpa by Francisco Pizarro in the early 1530s, the possible murder of the Tyrolean Ice Man (Oetzi) 5300 years ago and the analysis of the burial cloths allegedly associated with the crucifixion of Jesus Christ . Recent murders, including those associated with war crimes in the Balkans during the 1990s, can be studied using 14 C bomb pulse dating. This method has other forensic applications, including investigation of frauds related to food and wine counterfeiting, dating of opium crops and dating of substances used in biological warfare. AMS extends the applicability of the radiocarbon method, allowing the analysis of 14 C in submilligram organic samples. Specific molecular compounds extracted from bones, hair, skin and other carbon bearing substances of forensic significance can now be dated, enhancing the sensitivity and reliability of chronological determinations. AMS can also be used to analyse rare actinide isotopes released into the environment during the clandestine production of nuclear weapons or associated with the smuggling of nuclear materials. In

  14. Updating dating down under

    International Nuclear Information System (INIS)

    Bristow, J.W.

    1986-01-01

    The article deals with the Sensitive High Resolution Ion Microprobe (SHRIMP), Australia's only microprobe and its applications for geochronology. SHRIMP has the ability to analyse tiny areas (less than 30μm across) within crystals directly, the only sample preparation required being polishing of the crystal surface. Most analyses so far have been done on separated crystals prepared as grain mounts, although an increasing number of analyses are now being made of crystals in rock thin sections where their textural associations can be established. Important features of SHRIMP are its double-focusing mass spectrometer and great physical size, more than 8 meters long, employing a magnet weighing six tons. This enables the machine to distinguish ions with atomic masses differing by less than one part in ten thousand while at the same time having a very great sensitivity. SHRIMP was used for dating crustal zircons from southern African Kimberlites. Although low U and Pb abundances presents problems in peak selection and focusing on SHRIMP its was found that kimberlitic zircons could be dated successfully

  15. Exposure of [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} single-molecule magnets to soft X-rays: The effect of the counterions on radiation stability

    Energy Technology Data Exchange (ETDEWEB)

    Helmstedt, Andreas, E-mail: andreas.helmstedt@uni-bielefeld.de [Fakultaet fuer Physik, Universitaet Bielefeld, Universitaetsstrasse 25, D-33615 Bielefeld (Germany); Sacher, Marc D.; Gryzia, Aaron; Harder, Alexander; Brechling, Armin; Mueller, Norbert; Heinzmann, Ulrich [Fakultaet fuer Physik, Universitaet Bielefeld, Universitaetsstrasse 25, D-33615 Bielefeld (Germany); Hoeke, Veronika; Krickemeyer, Erich; Glaser, Thorsten [Fakultaet fuer Chemie, Universitaet Bielefeld, Universitaetsstrasse 25, D-33615 Bielefeld (Germany); Bouvron, Samuel; Fonin, Mikhail [Fachbereich Physik, Universitaet Konstanz, Universitaetsstrasse 10, D-78457 Konstanz (Germany)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} single-molecule magnets adsorbed on gold are investigated. Black-Right-Pointing-Pointer The oxidation state of the Mn{sup III} constituents changes under X-ray exposure. Black-Right-Pointing-Pointer The change is monitored by Mn-L{sub 3}-edge XAS. Black-Right-Pointing-Pointer Choice of anions strongly influences radiation stability of the SMM. Black-Right-Pointing-Pointer No influence of the sample morphology on radiation stability could be observed. - Abstract: X-ray absorption spectroscopy studies of the [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} single-molecule magnet deposited as a microcrystalline layer on gold substrates are presented. The oxidation state of the manganese centers changes from Mn{sup III} to Mn{sup II} due to irradiation with soft X-rays. The influence of the charge-neutralizing anions on the stability of [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} against soft X-ray exposure is investigated for the different anions tetraphenylborate (BPh{sub 4}{sup -}), lactate (C{sub 3}H{sub 5}O{sub 3}{sup -}) and perchlorate (ClO{sub 4}{sup -}). The exposure dependence of the radiation-induced reduction process is compared for [Mn{sup III}{sub 6}Cr{sup III}]{sup 3+} with the three different anions.

  16. Radiocarbon dates XXI

    International Nuclear Information System (INIS)

    Lowdon, J.A.; Blake, W. Jr.

    1981-01-01

    This list includes 105 radiocarbon age determinations on 104 geological samples made by the Radiocarbon Dating Laboratory. They are on samples from various areas as follows: Labrador Shelf (2); Newfoundland (12); Nova Scotia (2); New Brunswick (1); Quebec (3); Ontario (1); Manitoba (1); Alberta (2); British Columbia (15); Yukon Territory (35); Northwest Territories, Mainland (10); Northwest Territories, Arctic Archipelago (21). Details of background and standard for the 2 L and 5 L counters during the period from November 4, 1980 to October 31, 1981 are summarized in Tables 1 and 2; Table 3 gives the number of counts used to determine the average background and standard counting rates; and Table 4 lists the number of different background and standard gas preparations used for counting

  17. Development of BASIC program for radiocarbon dating

    International Nuclear Information System (INIS)

    Omoto, Kunio

    1982-01-01

    The continuous improvement of the system and the needs have produced the successful radiocarbon dating system of today to detect very low energy β-radioactivity. However, it still takes longer than 1,000 minutes for a sample counting. In a gas counting system, it is very difficult to keep the drift of impressed high voltage for a proportional counter less than 5 volts throughout the counting time. The temperature and the characteristics of gas itself also change during experiment. The accumulation of the above drift and errors are closely concerned with the accuracy and reliability of the radiocarbon date. The detection and reduction of the errors are only possible by using a ''fully automatic radiocarbon dating system'' linked to a personal computer system. In this paper, the author presents the BASIC (Beginners All-purpose Symbolic Instruction Code) program for a fully automatic radiocarbon dating system. In this paper, the outline of the system and software development are described. The details of the program include the description for gas-collection, gas-enclosing, plateau counting, β-ray counting, age calculation and data file maintenance. The author wrote numerous remark statements into the program so that it can be understood by users without detailed knowledge of the operation of a personal computer system or of the radiocarbon dating. Using this system, the author found that the radiocarbon dating has greatly progressed in speed and labour-saving, and that the accuracy and reliability of the date itself has also improved much than former manual systems. (Wakatsuki, Y.)

  18. Dates fruits classification using SVM

    Science.gov (United States)

    Alzu'bi, Reem; Anushya, A.; Hamed, Ebtisam; Al Sha'ar, Eng. Abdelnour; Vincy, B. S. Angela

    2018-04-01

    In this paper, we used SVM in classifying various types of dates using their images. Dates have interesting different characteristics that can be valuable to distinguish and determine a particular date type. These characteristics include shape, texture, and color. A system that achieves 100% accuracy was built to classify the dates which can be eatable and cannot be eatable. The built system helps the food industry and customer in classifying dates depending on specific quality measures giving best performance with specific type of dates.

  19. Diagnostic x-ray examinations in Poland in 2004 in view of the population exposure: The assessment of structure and trends

    International Nuclear Information System (INIS)

    Staniszewska, M. A.; Papierz, S.

    2006-01-01

    The paper presents the results of the Polish national survey of medical x-ray examinations performed in 2004. A questionnaire was used to collect the data on the number and types of x-ray examinations. The data covered most of x-ray laboratories in Poland, being under the dosimetric surveillance performed by the Radiation Protection Department at the Nofer Institute of Occupational Medicine in Lodz. The number of x-ray procedures in Poland in the year 2004 accounted for 32.4 million examinations, i.e. 830 procedures per 1000 inhabitants; the latter figure includes 65 specialist procedures and 61 dental examinations per 1000 of inhabitants, each. They were performed in over 3000 x-ray laboratories, including operational theatres and dental units. The majority of patients were at the age of 40-60 years and women made over 50% of all those examined. Owing to the modification of the heath care organisation, the profile of examinations performed in x-ray laboratories has changed. Nevertheless, conventional x-ray examinations are still in a majority, among which radiograph's of chest, spine and limbs are most frequently performed. It should be emphasised that the number of the hip joint radiograph's in infants and small children have decreased and practically photo fluorographic examinations have been eliminated from the diagnostic practice. The number of specialist procedures has evidently increased, and thus the frequency of these procedures in Poland and other European countries is comparable. (author)

  20. Correlations of DNA strand breaks and their repair with cell survival following acute exposure to mercury(II) and X-rays

    International Nuclear Information System (INIS)

    Cantoni, O.; Costa, M.

    1983-01-01

    Alkaline elution analysis demonstrates that both HgCl 2 and X-rays result in a rapid induction of DNA single-strand breaks at acutely cytotoxic doses (HgCl 2 , 25-100 microM for 60 min; X-rays, 150-600 rads) in cultured Chinese hamster ovary cells. Cytotoxicity, as measured by cell-plating efficiency, correlates linearly with the level of DNA breakage induced by both agents (HgCl 2 , r . 0.97; X-rays, r . 0.99), although a substantial difference in axis intercepts of the two linear regression lines indicates that a higher level of DNA damage was required by X-rays as compared with HgCl 2 to produce an equivalent level of cell killing. DNA damage induced by X-rays was rapidly repaired such that within 1 hr following treatment the elution rate of DNA from treated cells resembled that obtained in untreated cultures. In contrast, DNA damage after Hg 2+ insult was not repaired, and further damage was evident following a similar 1-hr recovery period. Addition of noncytotoxic, non-DNA-damaging concentrations of HgCl 2 (10 microM) to cells 15-45 min following treatment with X-rays greatly inhibited the repair of the DNA strand breaks. Thus, although both HgCl 2 and X-rays induce rapid and striking single-strand breaks in the DNA, persistence of Hg 2+ in the cell can inhibit the repair of these breaks. The inhibition of DNA repair by HgCl 2 may explain why this agent is not severely mutagenic or carcinogenic despite its ability to induce an X-ray-like DNA damage and why a lower level of mercury-induced DNA damage, compared with that induced by X-rays, was required to produce an equivalent level of cell death

  1. Exposure of Plastic Track Detectors to Relativistic Pb Beam for the Purpose of Providing Calibration for the DUBLIN-ESTEC Ultra Heavy Cosmic Ray Experiment Which was Exposed for Sixty-Nine Months in Earth Orbit

    CERN Multimedia

    2002-01-01

    % WA100 \\\\ \\\\ Solid state nuclear track detectors which formed part of the Dublin-ESTEC ultra heavy~cosmic~ray experiment aboard LDEF (Long Duration Exposure Facility) and which was deployed in Earth orbit for sixty-nine months, will be exposed to relativistic Pb ions. The experiment was the largest of its kind ever undertaken in space and has successfully accumulated more than fifteen times the world sample of cosmic ray nuclei in the region above Z~=~70. The data include the first significant sample of cosmic ray actinide elements and is of major astrophysical importance. The total number of ultra heavy nuclei (Z~$>$~70) in the Dublin-ESTEC sample is $\\sim$~2800. \\\\ \\\\The exposure will be very simple. A stack of detectors (20.5~cm~x~26~cm x~3~cm in size) will be irradiated with a low density beam of Pb ions (a few hundred per cm$^2$ would be ideal, but a wide range of densities and areas could be tolerated). The response of the detectors to these ions of known charge and velocity will be measured and the da...

  2. Dating ancient monuments by nuclear radiation

    International Nuclear Information System (INIS)

    Goedicke, C.

    2000-01-01

    combination with modern dosimeter materials a total error of less 5% might be achievable. As the zeroing event for optical luminescence is either heat or sunlight bleaching, optical techniques enable two more types of building material to be dated. Stones containing quartz or feldspar are datable because of the effect of bleaching. During the process of cutting into shapes adequate for use as a building material the surface-minerals of stones will be bleached by sunlight exposure. If further exposition to light is prevented, luminescence is accumulated again on unexposed surfaces. Two approaches, using either the C- 14 method or optical luminescence, are currently under investigation for mortar dating. Partially bleached quartz grains in mortar require a statistical treatment of the archaeological doses. (author)

  3. Dating technique tested

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    An analytical technique for dating ground water and polar ice up to a million years old has been successfully tested by scientists at Oak Ridge National Laboratory (ORNL). The system, known as a rare gas atom counter, extends the capabilities of resonance ionization mass spectrometry to include counting single atoms of krypton-81. The counter is composed of a pulsed dye laser operated in tandem with a mass spectrometer to separate the various isotopes of krypton. In a collaborative study, ORNL scientists recently used the method for the first time to count krypton-81 in a liter of ground water removed from a sandstone aquifer near Zurich. Fewer than 1000 krypton-81 atoms were isolated from the ground water samples. According to Bernard Lehman, a collaborating geochemist at the University of Bern, this first test proved that counting the small numbers of krypton-81 atoms necessary to make an estimate of the age of water could actually be done. Among the applications of this method, Lehman says, could be improved siting of locations for the disposal of radioactive wastes

  4. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  5. Analyzing three-dimensional position of region of interest using an image of contrast media using unilateral X-ray exposure

    International Nuclear Information System (INIS)

    Harauchi, Hajime; Gotou, Hiroshi; Tanooka, Masao

    1994-01-01

    Analyzing three-dimensional internal structure of object in an X-ray study is usually performed by using two or more of the incidents of an X-ray direction. In this report, we analyzed the three-dimensional position of tubes with a phantom by using both contrast media and imaging of one direction in the X-ray study. The concentration of the iodine in contrast media can be known by using the log-subtraction image of only the one-directional incident X-ray. Also the diameter of tube filled with contrast media is calculated by the concentration of iodine. So we can show the three-dimensional position of tubes geometrically, by the diameter of tube and the measured value of the film. We verified this method by an experiment according to the theory. (author)

  6. Correlation between Co-60 and X-ray exposures on radiation-induced charge buildup in silicon-on-insulator buried oxides

    International Nuclear Information System (INIS)

    Schwank, James R.; Shaneyfelt, Marty R.; Loemker, Rhonda Ann; Draper, Bruce L.; Dodd, Paul E.; Witczak, StevenN C.; Riewe, Leonard Charles; Ferlet-Cavrois, V.; Paillet, P.; Leray, J.-L.; Fleetwood, D.M.

    2000-01-01

    Large differences in charge buildup in SOI buried oxides can result between x-ray and Co-60 irradiations. The effects of bias configuration and substrate type on charge buildup and hardness assurance issues are explored

  7. Quality control in veterinary radiology: application of X-ray sets in veterinary practices and measurements of radiation exposure at taking

    International Nuclear Information System (INIS)

    Horvat, C.

    1986-10-01

    In a first part a survey was made by questionnaires from veterinary doctors about the existence and use of X-ray sets in their practices. Special attention is given to the quality of X-ray shots. In part two stray radiation measurements under typical conditions were performed and the radiation burden of the personnel estimated. The results is that because of the small number of shots the burden is safely below the legal limits. (G.Q.)

  8. Measurement and calculation of secondary gamma rays resulting from exposure of Fe, Pb, and H/sub 2/O to the ARERR-1 spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Makarious, A.S.; Ford, W.E. III; Turnbull, K.R.

    1977-08-01

    Integral experiments were performed to measure the angular distribution of secondary gamma rays produced when various thicknesses of Fe, Pb, and H/sub 2/O samples were exposed to bare and to B/sub 4/C-filtered neutron beams from the Research Reactor of Egypt. For selected experiments, multigroup coupled neutron-gamma cross sections and a discrete ordinates transport theory code (DOT4PI-M) were used to calculate the secondary gamma rays and the transport of primary gamma rays. Integral comparisons between the calculated and measured spectra were favorable. Graphical comparisons of the measured flux for various angles of incidence of the neutron beams on the samples, for various angles of exit on the transmitted side of the samples, and for various sample thicknesses are shown. The comparisons show that the angular distribution of secondary gamma rays for the three materials changes slightly with a change in the angle of beam incident on the sample, but increasing the angle between the normal to the sample and the detector by 60/sup 0/ decreases the measured secondary gamma-ray flux up to a factor of two. An investigation was made to determine the consequences of using single scatter Compton theory versus using discrete ordinates transport calculations to estimate the primary gamma-ray contribution to the measured photon spectra.

  9. Synergistic Exposure of Rice Seeds to Different Doses of γ-Ray and Salinity Stress Resulted in Increased Antioxidant Enzyme Activities and Gene-Specific Modulation of TC-NER Pathway

    Directory of Open Access Journals (Sweden)

    Anca Macovei

    2014-01-01

    Full Text Available Recent reports have underlined the potential of gamma (γ-rays as tools for seed priming, a process used in seed industry to increase seed vigor and to enhance plant tolerance to biotic/abiotic stresses. However, the impact of γ-rays on key aspects of plant metabolism still needs to be carefully evaluated. In the present study, rice seeds were challenged with different doses of γ-rays and grown in absence/presence of NaCl to assess the impact of these treatments on the early stages of plant life. Enhanced germination efficiency associated with increase in radicle and hypocotyl length was observed, while at later stages no increase in plant tolerance to salinity stress was evident. APX, CAT, and GR were enhanced at transcriptional level and in terms of enzyme activity, indicating the activation of antioxidant defence. The profiles of DNA damage accumulation were obtained using SCGE and the implication of TC-NER pathway in DNA damage sensing and repair mechanisms is discussed. OsXPB2, OsXPD, OsTFIIS, and OsTFIIS-like genes showed differential modulation in seedlings and plantlets in response to γ-irradiation and salinity stress. Altogether, the synergistic exposure to γ-rays and NaCl resulted in enhanced oxidative stress and proper activation of antioxidant mechanisms, thus being compatible with plant survival.

  10. A Protection Motivation Theory application to date rape education.

    Science.gov (United States)

    Singh, Shweta; Orwat, John; Grossman, Susan

    2011-12-01

    Date rape risk communication is a key component of education-based Date Rape Prevention Programs, common across colleges. In such programs, risk assessment in date rape is approached cautiously in order to avoid a tone of "victim blaming." Since it is important in the assessment of any risk to understand the surrounding social context of the risky situation and the individual's unique relationship with that social context, this study examines Protection Motivation Theory as it applies to handling the risk of date rape without victim blaming. The paper links individual personality and social contexts with risk communication. The study sample comprised 367 undergraduate women enrolled in a large Southern Public University. The study examines the relationships between dating activity, social competency, and type of information provided with the dependents variables of date rape related protection behavior (intent), belief, and knowledge. A factorial multiple analysis of covariance analysis found that the dependent variables had a significant relationship with aspects of social competency and dating activity. The exposure to varying information about date rape was not significantly related to the dependent variables of date rape-related protection behavior (intent), belief, and knowledge. The identification of social competency and dating activity status as protective factors in this study makes a significant contribution to the practice and research efforts in date rape education.

  11. Construction, calibration and testing of a ionization chamber for exposure measurement of X and gamma rays in the energy range from 40 keV up to 1250KEV

    International Nuclear Information System (INIS)

    Campos, Carlos A.A. Lima

    1982-01-01

    An unsealed thimble ionization chamber with connecting cable was designed, manufactured and tested at the IRD/CNEN, for exposure or exposure rate measurement of X or gamma rays in the energy range from 40 keV up to Cobalt-60. Recommendations given by IEC,TC-62(1974) were used as acceptance tests of the ionization chamber for use as a tertiary standard (field class instruments) in radiation therapy. In addition, intercomparison with commercially available chambers of reference class type were carried out in respect to field size dependence, energy dependence, short and long term stability.The results of those tests indicated the usefulness of the developed ionization chamber as a tertiary standard. (author)

  12. Evaluation of environmental radiation exposure

    International Nuclear Information System (INIS)

    Imai, Kazuhiko

    1974-01-01

    The environmental radiation exposure due to radioactive rare gases is most important both at the time of reactor accidents and also in the long-term normal operation of reactor plants. The exposure dose is usually calculated by means of computers. The procedure of the calculation on environmental exposure dose is divided in several consecutive steps. The calculational formulae frequently used and those proposed recently are given with the explanation on released radionuclides, release to the atmosphere, concentration in the atmosphere, β-ray exposure, γ-ray exposure, and calculation of long-term exposure dose. (Mori, K.)

  13. Effect of localized intraoperative x-rays irradiation followed by intermittent external exposure on certain histochemical parameters related to pancreatic function

    International Nuclear Information System (INIS)

    Abdel-Azeem, M.G.

    2005-01-01

    The present study was carried out to evaluate the pancreatic enzyme activities in rabbits, whose splenic part of pancreas was exposed to local intraoperative radiation therapy (IORT) at level of 30 Gy X-rays followed by fractionated external radiation therapy (ERT) at a total dose of 40 Gy (2 Gy day after day) starting from the 15th day following the local intraoperative irradiation. The control pancreas was that received only external X-rays radiation without local irradiation. The exocrine pancreatic functions were assessed by determination of insulin hormone and enzyme activity of lipase as well as alkaline and acid phosphatases. After local X-rays irradiation on days 2 and 10 and after external X-rays irradiation on days 23 , 33 , 43 and 53, technovit-8100 plastic embedding (Kulzer and Heraeus) was used to prepare the cold blocks. The quantitative morphometric method was used to evaluate the histochemical pancreatic activity of the irradiated and control pancreas of each rabbit. Most of the studied parameters recorded non-significant changes as a result of the applied different levels of X-rays irradiation, which would give the chance to use this type of irradiation in pancreatic radiotherapy without any hazards to the pancreas

  14. Dating method with /sup 39/Ar

    Energy Technology Data Exchange (ETDEWEB)

    Loosli, H H [Bern Univ. (Switzerland). Physikalisches Inst.

    1983-04-01

    The principles of a dating method based on the cosmic-ray-produced radioisotope /sup 39/Ar are given. Technical requirements such as background and standard gas samples and gas proportional counting systems are described. With samples extracted from Greenland ice it can be demonstrated that /sup 39/Ar ages agree with ages obtained by other methods. First results on ocean water samples show that with this isotope valuable information on ocean mixing and circulation can be expected. /sup 39/Ar results on groundwater samples disagree for some aquifers with conventional /sup 14/C ages; possible explanations are discussed, especially underground production of /sup 39/Ar.

  15. Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement

    International Nuclear Information System (INIS)

    Mothiram, Ursula; Brennan, Patrick C; Robinson, John; Lewis, Sarah J; Moran, Bernadette

    2013-01-01

    Following X-ray exposure, radiographers receive immediate feedback on detector exposure in the form of the exposure index (EI). To identify whether radiographers are meeting manufacturer-recommended EI (MREI) ranges for routine chest, abdomen and pelvis X-ray examinations under a variety of conditions and to examine factors affecting the EI. Data on 5000 adult X-ray examinations including the following variables were collected: examination parameters, EI values, patient gender, date of birth, date and time of examination, grid usage and the presence of implant or prosthesis. Descriptive statistics were used to summarize each data set and the Mann–Whitney U test was used to determine significant differences, with P < 0.05 indicating significance for all tests. Most examinations demonstrated EI values that were outside the MREI ranges, with significantly higher median EI values recorded for female patient radiographs than those for male patients for all manufacturers, indicating higher detector exposures for all units except for Philips digital radiography (DR), where increased EI values indicate lower exposure (P = 0.01). Median EI values for out of hours radiography were also significantly higher compared with normal working hours for all technologies (P ≤ 0.02). Significantly higher median EI values were demonstrated for Philips DR chest X-rays without as compared to those with the employment of a grid (P = 0.03), while significantly lower median EI values were recorded for Carestream Health computed radiography (CR) chest X-rays when an implant or prosthesis was present (P = 0.02). Non-adherence to MREIs has been demonstrated with EI value discrepancies being dependent on patient gender, time/day of exposure, grid usage and the presence of an implant or prosthesis. Retrospective evaluation of EI databases is a valuable tool to assess the need of quality improvement in routine DR

  16. Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement

    Energy Technology Data Exchange (ETDEWEB)

    Mothiram, Ursula; Brennan, Patrick C; Robinson, John; Lewis, Sarah J [Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, Sydney (Australia); Moran, Bernadette [Department of Clinical Medicine, Trinity College Dublin, Dublin (Ireland); Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, Sydney (Australia)

    2013-12-15

    Following X-ray exposure, radiographers receive immediate feedback on detector exposure in the form of the exposure index (EI). To identify whether radiographers are meeting manufacturer-recommended EI (MREI) ranges for routine chest, abdomen and pelvis X-ray examinations under a variety of conditions and to examine factors affecting the EI. Data on 5000 adult X-ray examinations including the following variables were collected: examination parameters, EI values, patient gender, date of birth, date and time of examination, grid usage and the presence of implant or prosthesis. Descriptive statistics were used to summarize each data set and the Mann–Whitney U test was used to determine significant differences, with P < 0.05 indicating significance for all tests. Most examinations demonstrated EI values that were outside the MREI ranges, with significantly higher median EI values recorded for female patient radiographs than those for male patients for all manufacturers, indicating higher detector exposures for all units except for Philips digital radiography (DR), where increased EI values indicate lower exposure (P = 0.01). Median EI values for out of hours radiography were also significantly higher compared with normal working hours for all technologies (P ≤ 0.02). Significantly higher median EI values were demonstrated for Philips DR chest X-rays without as compared to those with the employment of a grid (P = 0.03), while significantly lower median EI values were recorded for Carestream Health computed radiography (CR) chest X-rays when an implant or prosthesis was present (P = 0.02). Non-adherence to MREIs has been demonstrated with EI value discrepancies being dependent on patient gender, time/day of exposure, grid usage and the presence of an implant or prosthesis. Retrospective evaluation of EI databases is a valuable tool to assess the need of quality improvement in routine DR.

  17. Optically stimulated luminescence dating of rock surfaces

    DEFF Research Database (Denmark)

    Sohbati, Reza

    There are many examples of rock surfaces, rock art and stone structures whose ages are of great importance to the understanding of various phenomena in geology, climatology and archaeology. Optically stimulated luminescence (OSL) dating is a well-established chronological tool that has successfully...... to include the effects of the environmental dose rate. By fitting the model to the dose-depth variation from a single clast, four events (two light exposures of different durations each followed by a burial period) in the history of a single cobble are identified and quantified. However, the use of model...

  18. Prenatal pesticide exposure and PON1 genotype associated with adolescent body fat distribution evaluated by dual X-ray absorptiometry (DXA)

    DEFF Research Database (Denmark)

    Tinggaard, Jeanette; Wohlfahrt-Veje, C.; Husby, S

    2016-01-01

    ) at age 10-15. Prenatal pesticide exposure was associated with increased total, android, and gynoid fat% (DXA) at age 10-15 years after adjustment for sex, socioeconomic status, and puberty (all β = 0.5 standard deviation score (SDS) p ... (total fat: β = 0.7 SDS, android-gynoid ratio: β = 0.1, both p ... circumference were found. Prenatal pesticide exposure was associated with higher adolescent body fat content, including android fat deposition, independent of puberty. Girls appeared more susceptible than boys. Furthermore, the association depended on maternal and child PON1 Q192R genotype....

  19. The EOS 2D/3D X-ray imaging system: A cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure

    International Nuclear Information System (INIS)

    Faria, Rita; McKenna, Claire; Wade, Ros; Yang, Huiqin; Woolacott, Nerys; Sculpher, Mark

    2013-01-01

    Objectives: To evaluate the cost-effectiveness of the EOS ® 2D/3D X-ray imaging system compared with standard X-ray for the diagnosis and monitoring of orthopaedic conditions. Materials and methods: A decision analytic model was developed to quantify the long-term costs and health outcomes, expressed as quality-adjusted life years (QALYs) from the UK health service perspective. Input parameters were obtained from medical literature, previously developed cancer models and expert advice. Threshold analysis was used to quantify the additional health benefits required, over and above those associated with radiation-induced cancers, for EOS ® to be considered cost-effective. Results: Standard X-ray is associated with a maximum health loss of 0.001 QALYs, approximately 0.4 of a day in full health, while the loss with EOS ® is a maximum of 0.00015 QALYs, or 0.05 of a day in full health. On a per patient basis, EOS ® is more expensive than standard X-ray by between £10.66 and £224.74 depending on the assumptions employed. The results suggest that EOS ® is not cost-effective for any indication. Health benefits over and above those obtained from lower radiation would need to double for EOS to be considered cost-effective. Conclusion: No evidence currently exists on whether there are health benefits associated with imaging improvements from the use of EOS ® . The health benefits from radiation dose reductions are very small. Unless EOS ® can generate additional health benefits as a consequence of the nature and quality of the image, comparative patient throughput with X-ray will be the major determinant of cost-effectiveness

  20. The EOS 2D/3D X-ray imaging system: A cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Rita, E-mail: rita.nevesdefaria@york.ac.uk [Centre for Health Economics, University of York, York (United Kingdom); McKenna, Claire [Centre for Health Economics, University of York, York (United Kingdom); Wade, Ros; Yang, Huiqin; Woolacott, Nerys [Centre for Reviews and Dissemination, University of York, York (United Kingdom); Sculpher, Mark [Centre for Health Economics, University of York, York (United Kingdom)

    2013-08-15

    Objectives: To evaluate the cost-effectiveness of the EOS{sup ®} 2D/3D X-ray imaging system compared with standard X-ray for the diagnosis and monitoring of orthopaedic conditions. Materials and methods: A decision analytic model was developed to quantify the long-term costs and health outcomes, expressed as quality-adjusted life years (QALYs) from the UK health service perspective. Input parameters were obtained from medical literature, previously developed cancer models and expert advice. Threshold analysis was used to quantify the additional health benefits required, over and above those associated with radiation-induced cancers, for EOS{sup ®} to be considered cost-effective. Results: Standard X-ray is associated with a maximum health loss of 0.001 QALYs, approximately 0.4 of a day in full health, while the loss with EOS{sup ®} is a maximum of 0.00015 QALYs, or 0.05 of a day in full health. On a per patient basis, EOS{sup ®} is more expensive than standard X-ray by between £10.66 and £224.74 depending on the assumptions employed. The results suggest that EOS{sup ®} is not cost-effective for any indication. Health benefits over and above those obtained from lower radiation would need to double for EOS to be considered cost-effective. Conclusion: No evidence currently exists on whether there are health benefits associated with imaging improvements from the use of EOS{sup ®}. The health benefits from radiation dose reductions are very small. Unless EOS{sup ®} can generate additional health benefits as a consequence of the nature and quality of the image, comparative patient throughput with X-ray will be the major determinant of cost-effectiveness.

  1. Optimization of laboratory illumination in optical dating

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew; Lindvold, Lars René

    2017-01-01

    As part of the development of new laboratory lighting, we present a methodological approach applicable to the characterization of any light source intended for illumination in optical dating laboratories. We derive optical absorption cross-sections for quartz and feldspar from published data......-emitting diodes (LEDs); this comparison demonstrates the significant advantage of the LED sources over the filtered light sources, because essentially all of the reduction of both OSL and IRSL signals by the LEDs occurs at wavelengths to which the human eye is most sensitive. We conclude that exposure of quartz...... and feldspar extracts from various samples to the light from an LED with emission peak at 594 nm results in a 1% OSL or IRSL signal loss for a 48-h exposure at a power density of ~0.2 mW.cm-2....

  2. The new X-ray ordinance: what's new?

    International Nuclear Information System (INIS)

    Reichow, H.

    2000-01-01

    The augmented requirements for the minimisation of the radiation dose in medical exposure and the experiences gained from the implementation of the ordinance in force call for more extensive measures for reducing radiation, for quality assurance and expertise in radiological protection. In future physicians, dentists, veterinarians and other people using X-rays will have to bring their necessary expert knowledge regarding radiological protection up to date at regular intervals, and prove that they have done so. To protect the public against radiation exposure from targeted use, the limit value of the effective dose is reduced to 1 mSv in the calendar year. The dose level for the protection of people professionally exposed to radiation is reduced to 20 mSv. The further development of information technology and digital imaging demands that appropriate framework conditions be laid down in response to the changing requirements for radiation protection such as those in telemedicine and in digital recording and documentation possibilities in radiology. The draft further clarifies the distinction between the Radiological Protection Ordinance and the X-Ray Ordinance in relation to accelerators, in which electrons are accelerated with the aim of producing ionizing radiation, and reduces the limit energy from 3 MeV to 1 MeV. It is discussed to remove the X-ray therapy from the X-ray Ordinance and to insert it into the Radiological Protection Ordinance, in order to conform to the higher protection requirements in X-ray therapy. (orig.) [de

  3. Analysis of cell cycle regulated and regulating proteins following exposure of lung derived cells to sub-lethal doses of a-rays

    Science.gov (United States)

    Trani, D.; Claudio, P. P.; Cassone, M.; Lucchetti, C.; D'Agostino, L.; Caputi, M.; Giordano, A.

    Introduction Since the last century mankind had to face an increased exposure to man made and natural sources of radiation Radiation represents a therapeutic instrument for radiosensitive cancers as well as a cytotoxic agent for normal human tissues The effects of prolonged exposure to low doses of high energy radiation are still not well-known at the molecular and clinical level Understanding their molecular effects will aid in developing more tailored therapeutic strategies as well as implementing radio-protective measures essential prerequisite for the long-time permanence of men in space Objective of the study The general aim of this study was to evaluate the susceptibility and the response of lung epithelial cells to DNA damage induced by ionizing radiations We decided to study a panel of epithelial bronchial cell lines because of their fast-growth rate and their prominent exposure to both environmental and medical radiations The specific objective of our study was to qualitatively and semi-quantitatively assess the involvement and behaviour of selected genes in DNA damage DNA-repair mechanisms and apoptosis which follow radiation exposure with the aim to determine the involvement of the most promising targets for the early detection of radiation-mediated lung damage before chronic disease develops Methods Four epithelial cell lines one normal and three neoplastic were selected in order to detect and compare survival cell cycle and protein expression differences related to their different genetic asset

  4. Reliability and deviations of dates of the gamma-rays

    International Nuclear Information System (INIS)

    Matolin, M.

    1997-01-01

    In this article the method of the measurement of the terrestrial radioactivity by the transferable gamma-spectrometers with Na(TI) 76 x 76 mm with the scintillation detectors and the air gamma-spectrometry on the area of the Czech Republic is described. The radiometric map of the Czech Republic 1:50000, brought out in 1995, expressed in dose rate input of gamma-radiation, is based on regional (1957-1959) and detail (1960-1971) air measurement of the summary gamma-activity, of the air gamma-spectrometry (from 1976) and it was amplified with the results of the terrestrial and laboratory radiometric measurements. The method of feed back calibration was realized in 1994 with the means expression of the data in dose rate and equalization of data of the map. The map of the iso-lines with the step 10 nGy.h -1 was weaved by computer processing with the crining method. The regional terrestrial radiation in the Czech Republic, which is formed igneous, sedimentary and metamorphic minerals is in the range 15-200 (6-245) nGy.h -1 with the average value (65.6+-19.0) nGy.h -1 . The radiometric map of the Czech Republic 1:500000 was verified in 1995-1996 by comparison with the terrestrial gamma-spectrometric measurement. The middle difference of the comparing sets 2.1 nGy.h -1 indicate good regional equalization of the data while middle difference +-13.8 nGy.h -1 illustrate expected difference for the individual locality. The correlation coefficient of data of the comparing sets (N=81) is 0.942. The radiometric maps of the Saxon and of the Czech Republic in the border zone with the length about 250 km were compared. The middle difference (1.3+-13.6) nGy.h -1 nGy.h -1 indicate good unity of the data. The radiometric maps of the Poland and of the Czech Republic in the border zone with the length about 300 km were compared in 1977. The middle difference (12.1+-17.9) nGy.h -1 with higher values in the Czech Republic indicate the disunity of presentation of the radiometric data. The analysis of reasons of difference of the radiometric data are given [sk

  5. Optical stimulated luminescence (OSL) dating

    International Nuclear Information System (INIS)

    Banerjee, D.

    1999-01-01

    Since the pioneering work by Huntley et al. (1985), optical dating is being increasingly recognised as an important technique for establishing a time frame of deposition of sediments (Aitken, 1998). Optical dating differs from thermoluminescence (TL) dating in that visible/infrared light from lasers or LEDs (light-emitting-diodes) is used as a means of stimulation, in contrast to thermal stimulation. It has several advantages over TL dating: (i) the resetting of the OSL (optically stimulated luminescence) clock is more effective than that of TL clock; for sediments transported under water or in other situations where the sediment grains have undergone inhomogeneous bleaching, this property ensures that ages based on optical dating are generally more reliable than TL ages, (ii) the optical dating technique is non-destructive, and multiple readouts of the optical signal is possible; this feature has resulted in the development of single-aliquot and single-grain protocols (Murray and Wintle, 1999; Banerjee et al. 1999), (iii) the sample is not heated as in TL; thus, spurious luminescence is avoided and there is a significant reduction in blackbody radiation. Dating of materials which change phase on heating is also practical, and finally, (iv) thermal quenching of luminescence is negligible, allowing accurate estimation of kinetic parameters using standard techniques and providing access to deep OSL traps. This characteristic may be helpful in extending the limits of optical dating beyond the last 150 ka from a global point of view

  6. Luminescence dating of Netherland's sediments

    NARCIS (Netherlands)

    Wallinga, J.; Davids, F.; Dijkmans, J.W.A.

    2007-01-01

    Over the last decades luminescence dating techniques have been developed that allow earth scientists to determine the time of deposition of sediments. In this contribution we revity: 1) the development of the methodology, 2) tests of the reliability of luminescence dating on Netherlands' sediments;

  7. The isotopic dating of crystals

    International Nuclear Information System (INIS)

    Giuliani, G.; Cheilletz, A.

    1995-01-01

    The first part of this work deals with the answer to the question : why are the crystals dated ? Then, some isotopic dating methods are described : U-Th-Pb, K-Ar, 40 Ar/ 39 Ar, Rb-Sr, Sm-Nd, fission traces, carbon 14 methods. Examples concerning emeralds and diamonds are given. (O.L.). 12 refs., 2 figs

  8. The comparison of absolute dating (Radiocarbon dating) and relative dating of Pringapus and Gondosuli temples

    International Nuclear Information System (INIS)

    Faisal, W; Arumbinang, H; Taftazani, A; Widayati, S; Sumiyatno; Suhardi

    1996-01-01

    The absolute dating (radiocarbon, 14 C dating) and relative dating of Pringapus and Gondosuli temples in Temanggung regency (district) of Central Java Province have been carried out. The field sampling was done especially with the purpose to obtain vertical data, so that excavation method was adopted in the case. The main data were the ecofacts of organic habitation such as bones, woods, charcoals, shells, and paper artefacts. The artefacts data were used as a comparison. The comparative data analysis were conducted at Yogyakarta archaeological Department Laboratory, thus included dating of artefacts which were performed according to archaeological analysis procedures, generally based on the attributes attached to the artefacts, whereas the absolute dating of charcoal samples were performed in the Radiocarbon Dating Laboratory at Yogyakarta Nuclear Research Centre. Based on the relative dating of epigraphy content on the andesit rock from Gondosuli Temple which showed the year of 754 Saka or 832 AD, the Pringapus Temple was estimated to be built in the 850 AD. According to the absolute dating (Radiocarbon Dating with delta 13 C and tree ring corrections) the age for Gondosuli temple based on GDS/LU-2/Spit-7 samples is (384 -602) AD and from GDS/LU-2/Spit-8 = (452 - 652) AD. With these significant differences in the results obtained, it can be concluded that culture environment where the sample were collected already existed before the temple was built. Further investigation is still required

  9. Hemo rheological Changes Associated with Occupational Exposure to Low Doses Radiation from X-Ray Inspection Machines Influenced by Smoking Habits

    International Nuclear Information System (INIS)

    Ahmed, M.A.M.; El-khatib, A.M.; Naim, M.A.; Ali, F.M.

    2011-01-01

    The effects of low dose x-ray radiation on some rheological parameters of blood were investigated in 30 male x-ray workers and 20 healthy volunteers not occupationally exposed to any type of radiation and match in age. Each group was classified according to smoking habits. The analysis of the flow curve of all subjects was performed by applying power-law model and Bingham plastic model. The results indicated elevates in whole blood viscosity and yield stress in smoker subjects as compared with non-smoker subjects and also showed that the elevation of blood viscosity of smoker radiation workers are related to work duration in the radiation field.We have observed that cigarette smoking increases the hazardous effects of radiation through the increase of blood viscosity, which excess the risk of cardiovascular disease. So it is recommended to consider blood viscosity measurements to be included in routine medical investigation for occupational workers and rheological

  10. Late biological effects in the lung of C3H inbred mice following exposure to fast neutrons and 60Co-γ-rays

    International Nuclear Information System (INIS)

    Magdon, E.

    1980-01-01

    Histological changes in the lung tissue following local irradiation of the thorax of C 3 H inbred mice were analyzed. The investigation was continued up to 500 d following irradiation with 2 - 8 Gy neutrons and 4 - 30 Gy 60 Co γ-rays, respectively. The study revealed a clear dose dependence and higher effectivity of fast neutrons as to the late effects of the lungs. An increase of the portion of affected connective tissue in the lung was demonstrable already after a dose of 2.5 Gy neutrons and 5 Gy 60 Co γ-rays, respectively. The RBE of fast neutrons for late biological effects on the lung is discussed in connection with previous findings for the RBE of acute effects on tumor and normal tissue. (author)

  11. Effects of ha berlea rho dopensis extract on antioxidation and lipid peroxidation in rabbits after exposure to 60Co-γ-rays

    Directory of Open Access Journals (Sweden)

    Popov B.

    2013-01-01

    Full Text Available Haberlea rhodopensis extract (HRE possesses strong antioxidant activity. The aim of the present study was to evaluate the protective ability of HRE against oxidative damage induced by a non-lethal dose of 60Co-γ-rays. Experimental animals (New Zealand rabbits were exposed to 2.0 Gy γ-rays before and after HRE administration. Lipid peroxidation (MDA and activities of antioxidant enzymes superoxide dismutase (SOD and catalase (CAT were analyzed. Results show that administration of HRE before and after irradiation decreased the MDA level and increased SOD and CAT activity, thus providing protection against the radiation-induced decrease in antioxidative ability and increase in lipid peroxidation. This finding supports the idea that HRE is a potent free radical scavenger and antioxidant.

  12. Study on exposures in incidents situations involving X-ray generators of industrial use; Estudo de exposicoes em situacoes de incidentes envolvendo geradores de raios-X de uso industrial

    Energy Technology Data Exchange (ETDEWEB)

    Rios, Paulo B., E-mail: paulo@inovafi.com.br [Fisica aplicada a Inovacao Ltda. (INOVAFI), Campinas, SP (Brazil); Rios, Denise A. da S., E-mail: denise@inovafi.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    Case studies of accidents involving radiation sources provides valuable information for the improvement of equipment and procedures to be adopted to prevent their recurrence. Therefore, they are recommended as part of the licensing process of radiative facilities. However, when the equipment has no radiological protection requirements or have no record of accidents, an effective method to appropriate this knowledge necessary to improvements of process and project is the investigation of reported incidents and the proposition limit situations where exposures unlikely and even low intensity can occur. This work reviews incidents in X-ray equipment and thickness meters. Emergency situations are also studied in this type of equipment and in an accelerator of electrons self-shielded for curing of paints and varnishes. The exposure estimates are calculated from data collected in workplaces on the distance and time for each proposed case. Although there is no severe consequences to occupational health, the results can be used to improve the quality of training for operators and maintenance technicians, for proposing of new alarm systems and emergency teams procedures and may serve as a warning in inadvertent and avoidable situations of unnecessary exposures.

  13. Dose-response relationship for the induction of structural chromosome aberrations in human spermatozoa after in vitro exposure ti tritium. beta. -rays

    Energy Technology Data Exchange (ETDEWEB)

    Kamiguchi, Yujiroh; Tateno, Hiroyuki; Mikamo, Kazuya (Asahikawa Medical College (Japan). Department of Biological Sciences)

    1990-02-01

    THe effects of tritium (HTO) {beta}-rays on human sperm chromosomes were studied using our interspecific in vitro fertilization system between human spermatozoa and zona-free hamster oocytes. Semen samples were treated with media containing 1.53-24.3 mCi/ml HTO for about 80 min. 1290 spermatozoa from the controls and 1842 spermatozoa from the irradiated groups were karyotyped. The incidence of spermatozoa with structural chromosome aberrations increased linearly with increasing dosage. Breakage-type aberrations occurred far more frequently than exchange-type. Chromosome-type aberrations appeared far more frequently than chromatid-ype. All of these types of aberrations showed linear dose-dependent increases. The RBE valus of HTO {beta}-rays relative to X-rays were calculated for the above-mentioned 5 indices, respectively. Their RBE values franged from 1.89 to 3.00 when the absorbed dose was estimated to be the minimum, whereas the values ranged between 1.04 and 1.65 when the absorbed dose was estimated to be the maximum. (author). 15 refs.; 3 figs.; 4 tabs.

  14. DGT/ASN circular n. 04 of the 21. of April 2010 related to provisions for the prevention to ionizing ray exposure risks

    International Nuclear Information System (INIS)

    2010-01-01

    After an overview of the context of risk of exposure to ionizing radiation (potentially concerned activities, prevention policy based on radioprotection principles, regulation origin, radioprotection organization, specific inspection), this document presents the different regulatory provisions for the protection of workers against ionizing radiation hazards (scope of application, risk assessment, technical rules for workspace design, collective and individual protections, conditions for the follow-up of exposed workers, medical follow-up, work abnormal condition, radioprotection operating organisation, exposure to natural radioactivity). Then, a set of sheets is proposed, respectively containing regulatory information on employer obligations in terms of radioprotection, technical controls of radioprotection, individual protection equipment, worker information and education, radiological follow-up of classified workers, worker medical follow-up, work abnormal conditions, person with abilities in radioprotection, and a list of application decisions and orders

  15. Radiation exposure records management

    International Nuclear Information System (INIS)

    Boiter, H.P.

    1975-12-01

    Management of individual radiation exposure records begins at employment with the accumulation of data pertinent to the individual and any previous occupational radiation exposure. Appropriate radiation monitorinng badges or devices are issued and accountability established. A computer master file is initiated to include the individual's name, payroll number, social security number, birth date, assigned department, and location. From this base, a radiation exposure history is accumulated to include external ionizing radiation exposure to skin and whole body, contributing neutron exposure, contributing tritium exposure, and extremity exposure. It is used also to schedule bioassay sampling and in-vivo counts and to provide other pertinent information. The file is used as a basis for providing periodic reports to management and monthly exposure summaries to departmental line supervision to assist in planning work so that individual annual exposures are kept as low as practical. Radiation exposure records management also includes documentation of radiation surveys performed by the health physicist to establish working rates and the individual estimating and recording his estimated exposure on a day-to-day basis. Exposure information is also available to contribute to Energy Research and Development Administration statistics and to the National Transuranium Registry

  16. Determination of body diameters of babies, children and adolescents to list exposure values in X-ray diagnostics and estimation of organ dose values for typical X-ray examinations

    International Nuclear Information System (INIS)

    Bohmann, I.

    1990-04-01

    Measurements of body diameters of children did not exist as yet. Therefore the body diameters of 270 children, male and female, were measured, together with weight and height. The children were healthy and chosen at random. Six groups regarding age were considered: Newborn, one, five, seven, ten, fifteen years old. From the measurements mean values and standard deviations were calculated. In addition the correlations of the body diameters with age, weight, and height were investigated. The mean values of weight and height were compared to literature data. Exposure tables for children now, for the first time, can be established on the basis of empirical results. (orig.) [de

  17. AHP 47: A NIGHT DATE

    Directory of Open Access Journals (Sweden)

    Phun tshogs dbang rgyal ཕུན་ཚོགས་དབང་རྒྱལ།

    2017-04-01

    Full Text Available The author was born in 1993 in Ska chung (Gaqun Village, Nyin mtha' (Ningmute Township, Rma lho (Henan Mongolian Autonomous County, Rma lho (Huangnan Tibetan Autonomous Prefecture, Mtsho sngon (Qinghai Province, PR China. Night dating was popular for teenage boys some years ago. They rode horses and yaks when they went night dating. They generally rode yaks, because horses were important for their families and used for such important tasks as pursuing bandits and going to the county town for grain and supplies. An early experience with night dating is described.

  18. The use of a secondary standard x-ray exposure meter to calibrate a field instrument for use in output measurements

    International Nuclear Information System (INIS)

    1974-11-01

    It is stated that the recommended procedures have been closely correlated with ICRU Report 23 (1973), 'Measurements of absorbed dose in a phantom irradiated by a single beam of X- or gamma-rays'. The present report is contained in sections entitled: introduction; equipment and outline of procedures; calibration and use of field instrument in a phantom; calibration and use of the field instrument in air; local reference instrument; summary of recommended procedures. Appendices are entitled: the Perspex Intercomparison Phantom; the implications of applying an in-air calibration factor to readings made in a water phantom. (U.K.)

  19. Experimental Model for Retrospective Assessment of X-Ray Exposures in Dento-Maxillary Radiology Measured by Electron Paramagnetic Resonance in Tooth Enamel

    Directory of Open Access Journals (Sweden)

    Ioana Costina DÂNŞOREANU

    2009-12-01

    Full Text Available Electron paramagnetic resonance (EPR dosimetry of human tooth enamel has been widely used in measuring radiation doses in various scenarios. For experimental purposes in X-ray diagnostic or therapy human persons can not be involved. For such cases we have developed an EPR dosimetry technique making use of enamel of molars extracted from pigs. The method can evaluate doses and dose-profiles of irradiated teeth at low level as 50 – 100 mGy (in air. EPR-spectra acquisition, data processing and dose assessment were done using non-dedicated equipment, devices and software.

  20. Dating the humans by radiocarbon

    International Nuclear Information System (INIS)

    Fedi, M.E.

    2011-01-01

    Radiocarbon has become a very powerful tool used for dating. This paper deals with a specific application of 1 4C i.e. dating of humans. Attention is focused on those aspects that, if neglected, might lead to a misinterpretation of the results or to an unsatisfying accuracy of the measurement. After a brief description of the main principles on which the radiocarbon method is based and of Accelerator Mass Spectrometry, examples taken from the research activity of INFN-LABEC (Laboratorio di Tecniche Nucleari per I Beni Culturali) in Florence are presented. The case of the relic of St. Francis represents an example of dating not directly human remains but other objects that can be associated to them. The case of two burials from the archaeological area of Baratti-Populonia, in Tuscany, gives the possibility to show the importance of estimating the human palaeodiet when dating bone samples.

  1. Dating by electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Poupeau, G.; Rossi, A.M.

    1984-01-01

    Some natural materials behave like dosimeters in front of the ionizing particle flux coming from environmental radioactivity and the cosmic radiation. This property is used for the dating by Electron Paramagnetic Resonance (EPR). Before presenting the basic principles of the EPR analysis and the dating method which uses such a phenomenous, it is reviewed several types of application currently in course of development. (L.C.) [pt

  2. Radiocarbon dating of lake sediments

    OpenAIRE

    Pocevičius, Matas

    2016-01-01

    Matas Pocevičius, Radiocarbon dating of lake sediments, bachelor thesis, Vilnius University, Faculty of Physics, Department of General Physics and Spectroscopy, physics, Vilnius, 45 p., 2016. The aim of this study is to evaluate the possibility of radiocarbon dating application for Tapeliai lake bottom sediments. The literature review discusses topics related to accelerator mass spectrometry, principles of radiocarbon formation, importance of nuclear fallout for 14C, possible applications of ...

  3. Determination of the spallogenic radionuclides 26Al and 53Mn in Antartic meteorites with respect to cosmic ray exposure and terrestrial ages

    International Nuclear Information System (INIS)

    Herpers, U.; Sarafin, R.

    1987-01-01

    The spallogenic radionuclides 26 Al (T=7.18x10 5 a) and 53 Mn (T=3.8x10 6 a) were determined in 11 ordinary chondrites and 7 achondrites from Antarctica by nondestructive coincidence counting techniques and radiochemical neutron activation analysis. The results are discussed with respect to exposure ages, terrestrial residence times and possible genetic relationships of the meteorites investigated. The high terrestrial ages of some specimens (up to 800 000 years) are of importance for the study of the ice flow in Antarctica. (author)

  4. Radiocarbon dating of iron artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Cresswell, R. [Australian National Univ., Canberra, ACT (Australia). Dept. of Nuclear Physics

    1997-12-31

    Iron artefacts are generally dated by association or on stylistic grounds. This may not give a true indication of the date of manufacture, or may not be possible if the piece is out of context, ambiguous in style, or a copy. Obtaining a direct date on the artefact would be preferable. During the processes of manufacture, carbon is incorporated into the iron from the fuel source. If the fuel is of a material containing contemporaneous carbon, i.e. has an ambient radiocarbon signature, e.g. charcoal, then we may reliably radiocarbon date the artefact by extracting this carbon. Care must be taken, however, to ensure that re-working has not introduced multiple sources of carbon that would give an erroneous date. Detailed chemical analysis must precede radiocarbon analysis. Sample size is determined by carbon content, and before the advent of accelerator mass spectrometry, several tens of grams of carbon were required for radiocarbon dating (van der Merwe, 1969), prohibiting this method except for high-carbon cast-irons and bulk samples, e.g. caches of nails. AMS permits the analysis of sub-gram pieces of iron (Cresswell, 1991), thereby permitting the analysis of museum pieces with only minimal loss of material, and small fragments of iron recovered from archaeological sites. A few examples are given to illustrate these points. Paper no. 41; Extended abstract. 6 refs.

  5. Radiocarbon dating of iron artefacts

    International Nuclear Information System (INIS)

    Cresswell, R.

    1997-01-01

    Iron artefacts are generally dated by association or on stylistic grounds. This may not give a true indication of the date of manufacture, or may not be possible if the piece is out of context, ambiguous in style, or a copy. Obtaining a direct date on the artefact would be preferable. During the processes of manufacture, carbon is incorporated into the iron from the fuel source. If the fuel is of a material containing contemporaneous carbon, i.e. has an ambient radiocarbon signature, e.g. charcoal, then we may reliably radiocarbon date the artefact by extracting this carbon. Care must be taken, however, to ensure that re-working has not introduced multiple sources of carbon that would give an erroneous date. Detailed chemical analysis must precede radiocarbon analysis. Sample size is determined by carbon content, and before the advent of accelerator mass spectrometry, several tens of grams of carbon were required for radiocarbon dating (van der Merwe, 1969), prohibiting this method except for high-carbon cast-irons and bulk samples, e.g. caches of nails. AMS permits the analysis of sub-gram pieces of iron (Cresswell, 1991), thereby permitting the analysis of museum pieces with only minimal loss of material, and small fragments of iron recovered from archaeological sites. A few examples are given to illustrate these points

  6. Direct dating of human fossils.

    Science.gov (United States)

    Grün, Rainer

    2006-01-01

    The methods that can be used for the direct dating of human remains comprise of radiocarbon, U-series, electron spin resonance (ESR), and amino acid racemization (AAR). This review gives an introduction to these methods in the context of dating human bones and teeth. Recent advances in ultrafiltration techniques have expanded the dating range of radiocarbon. It now seems feasible to reliably date bones up to 55,000 years. New developments in laser ablation mass spectrometry permit the in situ analysis of U-series isotopes, thus providing a rapid and virtually non-destructive dating method back to about 300,000 years. This is of particular importance when used in conjunction with non-destructive ESR analysis. New approaches in AAR analysis may lead to a renaissance of this method. The potential and present limitations of these direct dating techniques are discussed for sites relevant to the reconstruction of modern human evolution, including Florisbad, Border Cave, Tabun, Skhul, Qafzeh, Vindija, Banyoles, and Lake Mungo. (c) 2006 Wiley-Liss, Inc.

  7. The therapeutic effect of a preparation extracted from tremella fuciformic berk (TFP) on the hematopoietic residual injury in mice induced by fractionated doses of 60Co γ-ray exposures

    International Nuclear Information System (INIS)

    Lu Shaoping; Yang Fengtong; Xu Chengxiong

    1989-01-01

    Hematopoietic residual injury, which is identified by the permanent defect of the blood forming system, could be induced in mice by repeated sublethal 60 Co γ-ray exposures. The number of hematopoietic stem cells (CFU-S) in mouse femora could be enhanced to a normal or near normal level if the 3 or 5 doses of 4.0 Gy irradiated mice were treated with a preparation extracted from an edible fungus Tremella Fuciformis Berk (TFP) 2 months after the irradiation. The number of endogenous spleen colonies and the spleen weight also increased markedly after the treatment. Because of the similarity found in the changes of hemaopoietic functions between the mice of residual injury and the patients of aplastic anemia, it is suggested that TFP may be useful to the patients of such blood disorder

  8. 30 CFR 62.100 - Purpose and scope; effective date.

    Science.gov (United States)

    2010-07-01

    ... HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.100 Purpose and scope; effective date. The purpose of these standards is to prevent the occurrence and reduce the progression of occupational noise-induced hearing loss among miners. This part sets forth mandatory health standards for each surface and...

  9. Skeletal deformations of newborn mice after X-ray exposure in fetal stage, with particular regard to hyperplastic growth phenomena in the neurocranium

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, I.

    1980-11-01

    The following comprises a literary review of the effects of prenatal X-ray irradiation, known mainly from the mouse. Our own investigations were carried out with NMRI mice which on gestation days 11-13, 11-16 or 14-16 were exposed to whole-body irradiation comprising individual daily doses of between 80 and 160 R. All the examinations were carried out on the 18th day of gestation. Findings of special nature were ascertained on the talus and calcaneus. These bones indicate that the X-ray irradiation has an accelerating effect on development. It was possible to ascertain a corresponding effect with regard to the deformations of the os supraoccipital. After irradiation with 3 x 120 R and 3 x 160 R on the 11th-13th gestation days, both inhibitory deformities and also the occurence of an additional, novel bone anlage were observed. These findings were subjected to detailed histological examinations. In doing so, it was found that following a single irradiation with 200 R on the 12th day of gestation, 86,6% of the fetuses showed hyperostoses on the roof of the skull. In 13,2% of all cases there was in addition a clear, abnormal chondrification of the neurocranium, at the same time combined with an excessive formation of the bone, which protruded deep into the cerebral hemispheres. The patogeneses of this excessive growth phenomenon is explained on the basis of the complex relationship between the fetal brain formation and the formation of the skull cap.

  10. Roentgenologic study on radius and ulna of a surgeon with skin carcinoma of the hand induced by occupational x-ray exposure

    International Nuclear Information System (INIS)

    Okuyama, Takeo; Suzuki, Soji; Yamada, Naoyuki; Okawa, Tomohiko; Tsuya, Akira.

    1977-01-01

    In this report, we described the results of microradiographic and microradioscopic studies on radius and ulna obtained from the amputated right forearm of a 76-year-old surgeon suffering from the radiation induced skin carcinoma of his hand. The period between the beginning of his radiological practice (mainly fluoroscopy) and the onset of skin carcinoma was about 20 years. The right forearm was amputated 30 years after the onset of the disease, in spite of all possible treatments. Microradiographic study on the cortex; 1. osteoporotic and/or disuse bone changes such as enlarged Haversian canals and multi-cavitary formation partially progressing to trabecular transformation of the cortex. 2. possibility of reconstructive process such as prominent existence of Haversian systems of low mineral density (immature osteon) and sufficient preservation of osteocyte lacunae. 3. more prominence of both findings in the distal portions of radius and ulna (5 cm proximal to the distal ends) probably much more intensively exposed by x-ray than the proximal portions (15 cm proximal to the distal ends). Microradioscopic study revealed such two processes of bone loss of the cortex as ''intracortical cavitation'' and ''endosteal erosion''. The former was reported to be encountered mainly in the presence of high bone turnover (hyperparathyroidism, acromegaly) and the latter mainly in low bone turnover (involutional osteoporosis), as stated by Meema. In our present material, intracortical cavitation appeared more prominent than endosteal erosion. Above-stated findings seemed to indicate the following two processes occured in the vital bone exposed by diagnostic x-ray during a long period of time (50 years); the one is the senile or involutional change and the other the rather increase in reconstructive or high bone turnover process. (auth.)

  11. “Protective Bystander Effects Simulated with the State-Vector Model”—HeLa x Skin Exposure to 137Cs Not Protective Bystander Response But Mammogram and Diagnostic X-Rays Are

    Science.gov (United States)

    Leonard, Bobby E.

    2008-01-01

    The recent Dose Response journal article “Protective Bystander Effects Simulated with the State-Vector Model” (Schollnberger and Eckl 2007) identified the suppressive (below natural occurring, zero primer dose, spontaneous level) dose response for HeLa x skin exposure to 137Cs gamma rays (Redpath et al 2001) as a protective Bystander Effect (BE) behavior. I had previously analyzed the Redpath et al (2001) data with a Microdose Model and conclusively showed that the suppressive response was from Adaptive Response (AR) radio-protection (Leonard 2005, 2007a). The significance of my microdose analysis has been that low LET radiation induced single (i.e. only one) charged particle traversals through a cell can initiate a Poisson distributed activation of AR radio-protection. The purpose of this correspondence is to clarify the distinctions relative to the BE and the AR behaviors for the Redpath groups 137Cs data, show conversely however that the Redpath group data for mammography (Ko et al 2004) and diagnostic (Redpath et al 2003) X-rays do conclusively reflect protective bystander behavior and also herein emphasize the need for radio-biologist to apply microdosimetry in planning and analyzing their experiments for BE and AR. Whether we are adamantly pro-LNT, adamantly anti-LNT or, like most of us, just simple scientists searching for the truth in radio-biology, it is important that we accurately identify our results, especially when related to the LNT hypothesis controversy. PMID:18846260

  12. Rapid degradation of the complex organic molecules in Martian surface rocks due to exposure to cosmic rays. Implications to the search of 'extinct' life on Mars by MSL and ExoMars

    Science.gov (United States)

    Pavlov, A.; Eigenbrode, J. L.; Glavin, D. P.; Floyd, M.; Mahaffy, P. R.

    2013-12-01

    Until recently, long-term exposure to cosmic rays has not been recognized as a major environmental factor, which can alter and destroy organic molecules in the Martian surface rocks. Recent modeling studies (e.g. Pavlov et al., 2012) suggested that organic molecules with masses >100 amu would be degraded in less than 1 billion years in the top 5 cm of the Martian rocks. That poses a serious challenge to the search of ancient molecules in the shallow subsurface of Mars. However, Pavlov et al. calculated the fraction of the survived organic molecules using conservative radiolysis constants derived from the gamma irradiation experiments on pure dry amino acid mixtures (Kminek and Bada, 2006). In this study we conducted a series of gamma irradiations of amino acids and carboxylic acids mixed with silica powder. We report that the addition of silicates dramatically increased the rate of organic degradation under gamma radiation. Using the newly derived radiolysis constants for amino acids and carboxylic acids in mineral mixtures, we recalculated the rate of organic degradation in the Martian rocks as a function of rocks' depth, chemical composition and weathering rates. Our results suggest that isolated organic molecules (acids) are likely to be altered or fully degraded in the surface rocks on Mars by cosmic rays in less than 10 million years unless some additional protective mechanisms are in place. We will discuss possible strategies for the MSL's search of the elusive ancient organic molecules to overcome the adverse effects of cosmic rays in the surface Martian rocks. References. Pavlov et al., 2012 GEOPHYSICAL RESEARCH LETTERS, doi:10.1029/2012GL052166 Kminek, G., and J. Bada (2006), Earth Planet. Sci. Lett., 245, 1-5, doi:10.1016/j.epsl.2006.03.008.

  13. Comprehensive study on estimation of gamma-ray exposure buildup factors for smart polymers as a potent application in nuclear industries

    Science.gov (United States)

    Sayyed, M. I.; AlZaatreh, M. Y.; Matori, K. A.; Sidek, H. A. A.; Zaid, M. H. M.

    2018-06-01

    In the present study, the exposure buildup factors (EBF) have been investigated using geometric progression (G-P) fitting method for different types of smart polymers (DMSO, PDMS, PES, PMA, PVDC, and PVDF) in the energy range of 0.015-15 MeV. From the calculations, the values of the EBF were depended on the incident photon energy, penetration depth as well as chemical composition of the polymers. In the intermediate energy region, the EBF values were reached at maximum point while in low and high energy regions, the EBF values were decreased at minimum point. The obtained results of the selected polymers have been compared in terms of EBF with Al2O3 and other common polymers such as PAN, Teflon and SR. The shielding effectiveness of the selected polymers is found to be comparable to the common polymers. The results of this work should be useful in radiation shielding applications such as in industry, medical and nuclear engineering.

  14. Induction and repair of DNA double-strand breaks in hippocampal neurons of mice of different age after exposure to 60Co γ-rays in vivo and in vitro

    Science.gov (United States)

    Kozhina, R. A.; Chausov, V. N.; Kuzmina, E. A.; Boreyko, A. V.

    2018-04-01

    One of the central problems of modern radiobiology is the study of DNA damage induction and repair mechanisms in central nervous system cells, in particular, in hippocampal cells. The study of the regularities of molecular damage formation and repair in the hippocampus cells is of special interest, because these cells, unlike most cells of the central nervous system (CNS), keep proliferative activity, i.e. ability to neurogenesis. Age-related changes in hippocampus play an important role, which could lead to radiosensitivity changes in neurons to the ionizing radiation exposure. Regularities in DNA double-strand breaks (DSB) induction and repair in different aged mice hippocampal cells in vivo and in vitro under the action of γ-rays 60Co were studied with DNA comet-assay. The obtained dose dependences of DNA DSB induction are linear both in vivo and in vitro. It is established that in young animals' cells, the degree of DNA damage is higher than in older animals. It is shown that repair kinetics is basically different for exposure in vivo and in vitro.

  15. Linguistic Dating of Biblical Texts

    DEFF Research Database (Denmark)

    Ehrensvärd, Martin Gustaf

    2003-01-01

    For two centuries, scholars have pointed to consistent differences in the Hebrew of certain biblical texts and interpreted these differences as reflecting the date of composition of the texts. Until the 1980s, this was quite uncontroversial as the linguistic findings largely confirmed the chronol......For two centuries, scholars have pointed to consistent differences in the Hebrew of certain biblical texts and interpreted these differences as reflecting the date of composition of the texts. Until the 1980s, this was quite uncontroversial as the linguistic findings largely confirmed...... the chronology of the texts established by other means: the Hebrew of Genesis-2 Kings was judged to be early and that of Esther, Daniel, Ezra, Nehemiah, and Chronicles to be late. In the current debate where revisionists have questioned the traditional dating, linguistic arguments in the dating of texts have...... come more into focus. The study critically examines some linguistic arguments adduced to support the traditional position, and reviewing the arguments it points to weaknesses in the linguistic dating of EBH texts to pre-exilic times. When viewing the linguistic evidence in isolation it will be clear...

  16. X-ray apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1985-01-01

    X-ray apparatus is described which has a shutter between the X-ray source and the patient. The shutter controls the level of radiation to which the patient is exposed instead of merely discontinuing the electric power supplied to the source. When the shutter is opened a radiation sensor senses the level of X-radiation. When a preset quantity of X-radiation has been measured an exposure control closes the shutter. Instead of using the radiation sensor, the integrated power supplied to the anode of the X-ray source may be measured. (author)

  17. Persistence of gamma-H2AX and 53BP1 foci in proliferating and nonproliferating human mammary epithelial cells after exposure to gamma-rays or iron ions

    Energy Technology Data Exchange (ETDEWEB)

    Groesser, Torsten; Chang, Hang; Fontenay, Gerald; Chen, James; Costes, Sylvain V.; Barcellos-Hoff, Mary Helen; Parvin, Bahram; Rydberg, Bjorn

    2010-12-22

    To investigate {gamma}-H2AX (phosphorylated histone H2AX) and 53BP1 (tumour protein 53 binding protein No. 1) foci formation and removal in proliferating and non-proliferating human mammary epithelial cells (HMEC) after exposure to sparsely and densely ionizing radiation under different cell culture conditions. HMEC cells were grown either as monolayers (2D) or in extracellular matrix to allow the formation of acinar structures in vitro (3D). Foci numbers were quantified by image analysis at various time points after exposure. Our results reveal that in non-proliferating cells under 2D and 3D cell culture conditions, iron-ion induced {gamma}-H2AX foci were still present at 72 h after exposure, although 53BP1 foci returned to control levels at 48 h. In contrast in proliferating HMEC, both {gamma}-H2AX and 53BP1 foci decreased to control levels during the 24-48 h time interval after irradiation under 2D conditions. Foci numbers decreased faster after {gamma}-ray irradiation and returned to control levels by 12 h regardless of marker, cell proliferation status, and cell culture condition. Conclusions: The disappearance of radiation induced {gamma}-H2AX and 53BP1 foci in HMEC have different dynamics that depend on radiation quality and proliferation status. Notably, the general patterns do not depend on the cell culture condition (2D versus 3D). We speculate that the persistent {gamma}-H2AX foci in iron-ion irradiated non-proliferating cells could be due to limited availability of double strand break (DSB) repair pathways in G0/G1-phase, or that repair of complex DSB requires replication or chromatin remodeling.

  18. Role of radiation dating technique - one example

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Shigueo [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Etchevarne, Carlos A. [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Fac. de Filosofia e Ciencias Humanas. Dept. Antropologia e Etnologia; Cano, Nilo F.; Munita, C.S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-07-01

    Full text: The great majority of archaeological or geological dating technique is based on radiation effect. The so called radioactivity method uses radioactive decays of elements. This is the case of the well known radiocarbon or carbon-14 method. Also the method of relating daughter nucleus to decaying nucleus, as in K-40/Ar-40, Th- 230/U-234, etc. Here we will concentrate in the method based on energy deposition in a solid by radiation from the disintegration of U-series and Th-series. {beta}-rays emitted by the decay of K-40 into Ca-40 (80%) and Ar-40 (11%) also contributes. The role of {alpha}, {beta} and {gamma} radiation emitted by radionuclides in the U-238 and Th-232 series and of {beta} rays from the decay of K-40, all of them in the soil irradiate anything in their course. For dating, we can have sediments as well as potteries produced by ancient people and became buried. The important process consists in transferring a fraction of the energy of radiation to the solid, mainly liberating electrons from valence band to conduction band and from there to traps. In many case the energy of the radiation is used to create defects which in turn create energy levels (traps) in the forbidden gap (or energy gap). There are three ways to recover the energy stored in the solid: (1) by emission of light optically stimulated (OSL), (2) by emission of light thermally stimulated (TL), (3) by microwave absorption (EPR or ESR). Using these techniques among several applications, we will present one to find the first settlers in the northeaster region of Brazil. (author)

  19. Role of radiation dating technique - one example

    International Nuclear Information System (INIS)

    Watanabe, Shigueo

    2012-01-01

    Full text: The great majority of archaeological or geological dating technique is based on radiation effect. The so called radioactivity method uses radioactive decays of elements. This is the case of the well known radiocarbon or carbon-14 method. Also the method of relating daughter nucleus to decaying nucleus, as in K-40/Ar-40, Th- 230/U-234, etc. Here we will concentrate in the method based on energy deposition in a solid by radiation from the disintegration of U-series and Th-series. β-rays emitted by the decay of K-40 into Ca-40 (80%) and Ar-40 (11%) also contributes. The role of α, β and γ radiation emitted by radionuclides in the U-238 and Th-232 series and of β rays from the decay of K-40, all of them in the soil irradiate anything in their course. For dating, we can have sediments as well as potteries produced by ancient people and became buried. The important process consists in transferring a fraction of the energy of radiation to the solid, mainly liberating electrons from valence band to conduction band and from there to traps. In many case the energy of the radiation is used to create defects which in turn create energy levels (traps) in the forbidden gap (or energy gap). There are three ways to recover the energy stored in the solid: (1) by emission of light optically stimulated (OSL), (2) by emission of light thermally stimulated (TL), (3) by microwave absorption (EPR or ESR). Using these techniques among several applications, we will present one to find the first settlers in the northeaster region of Brazil. (author)

  20. Comparable Senescence Induction in Three-dimensional Human Cartilage Model by Exposure to Therapeutic Doses of X-rays or C-ions.

    Science.gov (United States)

    Hamdi, Dounia Houria; Chevalier, François; Groetz, Jean-Emmanuel; Durantel, Florent; Thuret, Jean-Yves; Mann, Carl; Saintigny, Yannick

    2016-05-01

    Particle therapy using carbon ions (C-ions) has been successfully used in the treatment of tumors resistant to conventional radiation therapy. However, the potential side effects to healthy cartilage exposed to lower linear energy transfer (LET) ions in the beam track before the tumor have not been evaluated. The aim of the present study was to assess the extent of damage after C-ion irradiation in a 3-dimensional (3D) cartilage model close to human homeostasis. Primary human articular chondrocytes from a healthy donor were cultured in a collagen scaffold to construct a physioxic 3D cartilage model. A 2-dimensional (2D) culture was used as a reference. The cells were irradiated with a single dose of a monoenergetic C-ion beam with a LET of approximatively 30 keV/μm. This LET corresponds to the entrance channel of C-ions in the shallow healthy tissues before the spread-out Bragg peak (∼100 keV/μm) during hadron therapy protocols. The same dose of X-rays was used as a reference. Survival, cell death, and senescence assays were performed. As expected, in the 2D culture, C-ions were more efficient than X-rays in reducing cell survival with a relative biological effectiveness of 2.6. This correlated with stronger radiation-induced senescence (two-fold) but not with higher cell death induction. This differential effect was not reflected in the 3D culture. Both ionizing radiation types induced a comparable rate of senescence induction in the 3D model. The greater biological effectiveness of C-ions compared with low LET radiation when evaluated in treatment planning systems might be misevaluated using 2D culture experiments. Radiation-induced senescence is an important factor of potential cartilage attrition. The present data should encourage the scientific community to use relevant models and beams to improve the use of charged particles with better safety for patients. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.