WorldWideScience

Sample records for ratio snr measurements

  1. Skalabilitas Signal to Noise Ratio (SNR pada Pengkodean Video dengan Derau Gaussian

    Directory of Open Access Journals (Sweden)

    Agus Purwadi

    2015-04-01

    Full Text Available In video transmission, there is a possibility of packet lost an d a large load variation on the bandwidth. These are the source of network congestion, which can interfere the communication data rate. This study discusses a system to overcome the congestion with Signal-to-noise ratio (SNR scalability-based approach, for the video sequence encoding method into two layers, which is a solution to decrease encoding mode for each packet and channel coding rate. The goal is to minimize any distortion from the source to the destination. The coding system used is a video coding standards that is MPEG-2 or H.263 with SNR scalability. The algorithm used for motion compensation, temporal redundancy and spatial redundancy is the Discrete Cosine Transform (DCT and quantization. The transmission error is simulated by adding Gaussian noise (error on motion vectors. From the simulation results, the SNR and Peak Signal to Noise Ratio (PSNR in the noisy video frames decline with averages of 3dB and 4dB respectively.

  2. On the low SNR capacity of maximum ratio combining over rician fading channels with full channel state information

    KAUST Repository

    Benkhelifa, Fatma; Rezki, Zouheir; Alouini, Mohamed-Slim

    2013-01-01

    In this letter, we study the ergodic capacity of a maximum ratio combining (MRC) Rician fading channel with full channel state information (CSI) at the transmitter and at the receiver. We focus on the low Signal-to-Noise Ratio (SNR) regime and we show that the capacity scales as L ΩK+L SNRx log(1SNR), where Ω is the expected channel gain per branch, K is the Rician fading factor, and L is the number of diversity branches. We show that one-bit CSI feedback at the transmitter is enough to achieve this capacity using an on-off power control scheme. Our framework can be seen as a generalization of recently established results regarding the fading-channels capacity characterization in the low-SNR regime. © 2012 IEEE.

  3. On the low SNR capacity of maximum ratio combining over rician fading channels with full channel state information

    KAUST Repository

    Benkhelifa, Fatma

    2013-04-01

    In this letter, we study the ergodic capacity of a maximum ratio combining (MRC) Rician fading channel with full channel state information (CSI) at the transmitter and at the receiver. We focus on the low Signal-to-Noise Ratio (SNR) regime and we show that the capacity scales as L ΩK+L SNRx log(1SNR), where Ω is the expected channel gain per branch, K is the Rician fading factor, and L is the number of diversity branches. We show that one-bit CSI feedback at the transmitter is enough to achieve this capacity using an on-off power control scheme. Our framework can be seen as a generalization of recently established results regarding the fading-channels capacity characterization in the low-SNR regime. © 2012 IEEE.

  4. The position dependent influence that sensitivity correction processing gives the signal-to-noise ratio measurement in parallel imaging

    International Nuclear Information System (INIS)

    Murakami, Koichi; Yoshida, Koji; Yanagimoto, Shinichi

    2012-01-01

    We studied the position dependent influence that sensitivity correction processing gave the signal-to-noise ratio (SNR) measurement of parallel imaging (PI). Sensitivity correction processing that referred to the sensitivity distribution of the body coil improved regional uniformity more than the sensitivity uniformity correction filter with a fixed correction factor. In addition, the position dependent influence to give the SNR measurement in PI was different from the sensitivity correction processing. Therefore, if we divide SNR of the sensitivity correction processing image by SNR of the original image in each pixel and calculate SNR ratio, we can show the position dependent influence that sensitivity correction processing gives the SNR measurement in PI. It is with an index of the sensitivity correction processing precision. (author)

  5. Signal-to-noise ratio measurement in parallel MRI with subtraction mapping and consecutive methods

    International Nuclear Information System (INIS)

    Imai, Hiroshi; Miyati, Tosiaki; Ogura, Akio; Doi, Tsukasa; Tsuchihashi, Toshio; Machida, Yoshio; Kobayashi, Masato; Shimizu, Kouzou; Kitou, Yoshihiro

    2008-01-01

    When measuring the signal-to-noise ratio (SNR) of an image the used parallel magnetic resonance imaging, it was confirmed that there was a problem in the application of past SNR measurement. With the method of measuring the noise from the background signal, SNR with parallel imaging was higher than that without parallel imaging. In the subtraction method (NEMA standard), which sets a wide region of interest, the white noise was not evaluated correctly although SNR was close to the theoretical value. We proposed two techniques because SNR in parallel imaging was not uniform according to inhomogeneity of the coil sensitivity distribution and geometry factor. Using the first method (subtraction mapping), two images were scanned with identical parameters. The SNR in each pixel divided the running mean (7 by 7 pixels in neighborhood) by standard deviation/√2 in the same region of interest. Using the second (consecutive) method, more than fifty consecutive scans of the uniform phantom were obtained with identical scan parameters. Then the SNR was calculated from the ratio of mean signal intensity to the standard deviation in each pixel on a series of images. Moreover, geometry factors were calculated from SNRs with and without parallel imaging. The SNR and geometry factor using parallel imaging in the subtraction mapping method agreed with those of the consecutive method. Both methods make it possible to obtain a more detailed determination of SNR in parallel imaging and to calculate the geometry factor. (author)

  6. Multipath detection with the combination of SNR measurements - Example from urban environment

    Science.gov (United States)

    Špánik, Peter; Hefty, Ján

    2017-12-01

    Multipath is one of the most severe station-dependent error sources in both static and kinematic positioning. Relatively new and simple detection technique using the Signal-to-Noise (SNR) measurements on three frequencies will be presented based on idea of Strode and Groves. Exploitation of SNR measurements is benefi cial especially for their unambiguous character. Method is based on the fact that SNR values are closely linked with estimation of pseudo-ranges and phase measurements during signal correlation processing. Due to this connection, combination of SNR values can be used to detect anomalous behavior in received signal, however some kind of calibration in low multipath environment has to be done previously. In case of multipath, phase measurements on different frequencies will not be affected in the same manner. Specular multipath, e.g. from building wall introduces additional path delay which is interpreted differently on each of the used carrier, due to different wavelengths. Experimental results of multipath detection in urban environment will be presented. Originally proposed method is designed to work with three different frequencies in each epoch, thus only utilization of GPS Block II-F and Galileo satellites is possible. Simplification of detection statistics to use only two frequencies is made and results using GPS and GLONASS systems are presented along with results obtained using original formula.

  7. SNR characteristics of 850-nm OEIC receiver with a silicon avalanche photodetector.

    Science.gov (United States)

    Youn, Jin-Sung; Lee, Myung-Jae; Park, Kang-Yeob; Rücker, Holger; Choi, Woo-Young

    2014-01-13

    We investigate signal-to-noise ratio (SNR) characteristics of an 850-nm optoelectronic integrated circuit (OEIC) receiver fabricated with standard 0.25-µm SiGe bipolar complementary metal-oxide-semiconductor (BiCMOS) technology. The OEIC receiver is composed of a Si avalanche photodetector (APD) and BiCMOS analog circuits including a transimpedance amplifier with DC-balanced buffer, a tunable equalizer, a limiting amplifier, and an output buffer with 50-Ω loads. We measure APD SNR characteristics dependence on the reverse bias voltage as well as BiCMOS circuit noise characteristics. From these, we determine the SNR characteristics of the entire OEIC receiver, and finally, the results are verified with bit-error rate measurement.

  8. A Semi-Empirical SNR Model for Soil Moisture Retrieval Using GNSS SNR Data

    Directory of Open Access Journals (Sweden)

    Mutian Han

    2018-02-01

    Full Text Available The Global Navigation Satellite System-Interferometry and Reflectometry (GNSS-IR technique on soil moisture remote sensing was studied. A semi-empirical Signal-to-Noise Ratio (SNR model was proposed as a curve-fitting model for SNR data routinely collected by a GNSS receiver. This model aims at reconstructing the direct and reflected signal from SNR data and at the same time extracting frequency and phase information that is affected by soil moisture as proposed by K. M. Larson et al. This is achieved empirically through approximating the direct and reflected signal by a second-order and fourth-order polynomial, respectively, based on the well-established SNR model. Compared with other models (K. M. Larson et al., T. Yang et al., this model can improve the Quality of Fit (QoF with little prior knowledge needed and can allow soil permittivity to be estimated from the reconstructed signals. In developing this model, we showed how noise affects the receiver SNR estimation and thus the model performance through simulations under the bare soil assumption. Results showed that the reconstructed signals with a grazing angle of 5°–15° were better for soil moisture retrieval. The QoF was improved by around 45%, which resulted in better estimation of the frequency and phase information. However, we found that the improvement on phase estimation could be neglected. Experimental data collected at Lamasquère, France, were also used to validate the proposed model. The results were compared with the simulation and previous works. It was found that the model could ensure good fitting quality even in the case of irregular SNR variation. Additionally, the soil moisture calculated from the reconstructed signals was about 15% closer in relation to the ground truth measurements. A deeper insight into the Larson model and the proposed model was given at this stage, which formed a possible explanation of this fact. Furthermore, frequency and phase information

  9. Multipath detection with the combination of SNR measurements – Example from urban environment

    Directory of Open Access Journals (Sweden)

    Špánik Peter

    2017-12-01

    Full Text Available Multipath is one of the most severe station-dependent error sources in both static and kinematic positioning. Relatively new and simple detection technique using the Signal-to-Noise (SNR measurements on three frequencies will be presented based on idea of Strode and Groves. Exploitation of SNR measurements is benefi cial especially for their unambiguous character. Method is based on the fact that SNR values are closely linked with estimation of pseudo-ranges and phase measurements during signal correlation processing. Due to this connection, combination of SNR values can be used to detect anomalous behavior in received signal, however some kind of calibration in low multipath environment has to be done previously. In case of multipath, phase measurements on different frequencies will not be affected in the same manner. Specular multipath, e.g. from building wall introduces additional path delay which is interpreted differently on each of the used carrier, due to different wavelengths. Experimental results of multipath detection in urban environment will be presented. Originally proposed method is designed to work with three different frequencies in each epoch, thus only utilization of GPS Block II-F and Galileo satellites is possible. Simplification of detection statistics to use only two frequencies is made and results using GPS and GLONASS systems are presented along with results obtained using original formula.

  10. Accuracy of signal-to-noise ratio measurement method for magnetic resonance images

    International Nuclear Information System (INIS)

    Ogura, Akio; Miyai, Akira; Maeda, Fumie; Fukutake, Hiroyuki; Kikumoto, Rikiya

    2003-01-01

    The signal-to-noise ratio (SNR) of a magnetic resonance image is a common measure of imager performance. However, evaluations for the calculation of the SNR use various methods. A problem with measuring SNR is caused by the distortion of noise statistics in commonly used magnitude images. In this study, measurement accuracy was compared among four methods of evaluating SNR according to the size and position of regions of interest (ROIs). The results indicated that the method that used the difference between two images showed the best agreement with the theoretical value. In the method that used a single image, the SNR calculated by using a small size of ROI showed better agreement with the theoretical value because of noise bias and image artifacts. However, in the method that used the difference between two images, a large size of ROI was better in reducing statistical errors. In the same way, the methods that used air noise and air signal were better when applied to a large ROI. In addition, the image subtraction process used to calculate pixel-by-pixel differences in images may reach zero on a minus pixel value when using an image processor with the MRI system and apparatuses associated with it. A revised equation is presented for this case. It is important to understand the characteristics of each method and to choose a suitable method carefully according to the purpose of the study. (author)

  11. Assessment of broadband SNR estimation for hearing aid applications

    DEFF Research Database (Denmark)

    May, Tobias; Kowalewski, Borys; Fereczkowski, Michal

    2017-01-01

    was systematically investigated. The most accurate approach utilized an estimation of the clean speech power spectral density (PSD) and the noisy speech power across a sliding window of 1280 ms and achieved an total SNR estimation error below 3 dB across a wide variety of background noises and input SNRs......An accurate estimation of the broadband input signal-to-noise ratio (SNR) is a prerequisite for many hearing-aid algorithms. An extensive comparison of three SNR estimation algorithms was performed. Moreover, the influence of the duration of the analysis window on the SNR estimation performance...

  12. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2017-01-01

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  13. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas

    2017-09-18

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  14. The effect of signal to noise ratio on accuracy of temperature measurements for Brillouin lidar in water

    Science.gov (United States)

    Liang, Kun; Niu, Qunjie; Wu, Xiangkui; Xu, Jiaqi; Peng, Li; Zhou, Bo

    2017-09-01

    A lidar system with Fabry-Pérot etalon and an intensified charge coupled device can be used to obtain the scattering spectrum of the ocean and retrieve oceanic temperature profiles. However, the spectrum would be polluted by noise and result in a measurement error. To analyze the effect of signal to noise ratio (SNR) on the accuracy of measurements for Brillouin lidar in water, the theory model and characteristics of SNR are researched. The noise spectrums with different SNR are repetitiously measured based on simulation and experiment. The results show that accuracy is related to SNR, and considering the balance of time consumption and quality, the average of five measurements is adapted for real remote sensing under the pulse laser conditions of wavelength 532 nm, pulse energy 650 mJ, repetition rate 10 Hz, pulse width 8 ns and linewidth 0.003 cm-1 (90 MHz). Measuring with the Brillouin linewidth has a better accuracy at a lower temperature (15 °C), based on the classical retrieval model we adopt. The experimental results show that the temperature error is 0.71 °C and 0.06 °C based on shift and linewidth respectively when the image SNR is at the range of 3.2 dB-3.9 dB.

  15. Estimating achievable signal-to-noise ratios of MRI transmit-receive coils from radiofrequency power measurements: applications in quality control

    International Nuclear Information System (INIS)

    Redpath, T.W.

    2000-01-01

    The inverse relationship between the radiofrequency (RF) power needed to transmit a 90 deg. RF pulse, and the signal-to-noise ratio (SNR) available from a transmit-receive RF coil is well known. The theory is restated and a formula given for the signal-to-noise ratio from water, achievable from a single-shot MRI experiment, in terms of the net forward RF power needed for a rectangular 90 deg. RF pulse of known shape and duration. The result is normalized to a signal bandwidth of 1 Hz and a sample mass of 1 g. The RF power information needed is available on most commercial scanners, as it is used to calculate specific absorption rates for RF tissue heating. The achievable SNR figure will normally be larger that that actually observed, mainly because of receiver noise, but also because of inaccuracies in setting RF pulse angles, and relaxation effects. Phantom experiments were performed on the transmit-receive RF head coil of a commercial MRI system at 0.95 T using a projection method. The measured SNR agreed with that expected from the formula for achievable SNR once a correction was made for the noise figure of the receiving chain. Comparisons of measured SNR figures with those calculated from RF power measurements are expected to be of value in acceptance testing and quality control. (author)

  16. Design of planar microcoil-based NMR probe ensuring high SNR

    Science.gov (United States)

    Ali, Zishan; Poenar, D. P.; Aditya, Sheel

    2017-09-01

    A microNMR probe for ex vivo applications may consist of at least one microcoil, which can be used as the oscillating magnetic field (MF) generator as well as receiver coil, and a sample holder, with a volume in the range of nanoliters to micro-liters, placed near the microcoil. The Signal-to-Noise ratio (SNR) of such a probe is, however, dependent not only on its design but also on the measurement setup, and the measured sample. This paper introduces a performance factor P independent of both the proton spin density in the sample and the external DC magnetic field, and which can thus assess the performance of the probe alone. First, two of the components of the P factor (inhomogeneity factor K and filling factor η ) are defined and an approach to calculate their values for different probe variants from electromagnetic simulations is devised. A criterion based on dominant component of the magnetic field is then formulated to help designers optimize the sample volume which also affects the performance of the probe, in order to obtain the best SNR for a given planar microcoil. Finally, the P factor values are compared between different planar microcoils with different number of turns and conductor aspect ratios, and planar microcoils are also compared with conventional solenoids. These comparisons highlight which microcoil geometry-sample volume combination will ensure a high SNR under any external setup.

  17. Design of planar microcoil-based NMR probe ensuring high SNR

    Directory of Open Access Journals (Sweden)

    Zishan Ali

    2017-09-01

    Full Text Available A microNMR probe for ex vivo applications may consist of at least one microcoil, which can be used as the oscillating magnetic field (MF generator as well as receiver coil, and a sample holder, with a volume in the range of nanoliters to micro-liters, placed near the microcoil. The Signal-to-Noise ratio (SNR of such a probe is, however, dependent not only on its design but also on the measurement setup, and the measured sample. This paper introduces a performance factor P independent of both the proton spin density in the sample and the external DC magnetic field, and which can thus assess the performance of the probe alone. First, two of the components of the P factor (inhomogeneity factor K and filling factor η are defined and an approach to calculate their values for different probe variants from electromagnetic simulations is devised. A criterion based on dominant component of the magnetic field is then formulated to help designers optimize the sample volume which also affects the performance of the probe, in order to obtain the best SNR for a given planar microcoil. Finally, the P factor values are compared between different planar microcoils with different number of turns and conductor aspect ratios, and planar microcoils are also compared with conventional solenoids. These comparisons highlight which microcoil geometry-sample volume combination will ensure a high SNR under any external setup.

  18. Improved SNR of phased-array PERES coils via simulation study

    International Nuclear Information System (INIS)

    RodrIguez, Alfredo O; Medina, LucIa

    2005-01-01

    A computational comparison of signal-to-noise ratio (SNR) was performed between a conventional phased array of two circular-shaped coils and a petal resonator surface array. The quasi-static model and phased-array optimum SNR were combined to derive an SNR formula for each array. Analysis of mutual inductance between coil petals was carried out to compute the optimal coil separation and optimum number of petal coils. Mutual interaction between coil arrays was not included in the model because this does not drastically affect coil performance. Phased arrays of PERES coils show a 114% improvement in SNR over that of the simplest circular configuration. (note)

  19. Low-SNR Capacity of Parallel IM-DD Optical Wireless Channels

    KAUST Repository

    Chaaban, Anas

    2016-11-29

    The capacity of parallel intensity-modulation and direct-detection (IM-DD) optical wireless channels with total average intensity and per-channel peak intensity constraints is studied. The optimal intensity allocation at low signal-to-noise ratio (SNR) is derived, leading to the capacity-achieving onoff keying (OOK) distribution. Interestingly, while activating the strongest channel is optimal if (i) the peak intensity is fixed, this is not the case if (ii) the peak intensity is proportional to the average intensity. The minimum average optical intensity per bit is also studied, and is characterized for case (i) where it is achievable at low SNR. However, in case (ii), the average optical intensity per bit grows indefinitely as SNR decreases, indicating that lower optical intensity per bit can be achieved at moderate SNR than at low SNR.

  20. Using optical fibers with different modes to improve the signal-to-noise ratio of diffuse correlation spectroscopy flow-oximeter measurements

    OpenAIRE

    He, Lian; Lin, Yu; Shang, Yu; Shelton, Brent J.; Yu, Guoqiang

    2013-01-01

    The dual-wavelength diffuse correlation spectroscopy (DCS) flow-oximeter is an emerging technique enabling simultaneous measurements of blood flow and blood oxygenation changes in deep tissues. High signal-to-noise ratio (SNR) is crucial when applying DCS technologies in the study of human tissues where the detected signals are usually very weak. In this study, single-mode, few-mode, and multimode fibers are compared to explore the possibility of improving the SNR of DCS flow-oximeter measure...

  1. Comparison study on CNR and SNR of thoracic spine lateral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Min, Jung Whan; Lyu, Kwang Yeul [Dept. of Radiology, Shingu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, College of Health Science, Korea University, Seoul (Korea, Republic of); Jeong, Hei Woun [Dept. of Radiological Science, Beakseok Culture University, Cheonan (Korea, Republic of); Lee, Joo Ah [Dept. of Oncology, Catholic University of Korea Incheon St.Mary,s Hospital, Incheon (Korea, Republic of); Jung, Jae Hong [Dept. of Oncology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Sung, Dong Chan [Dept. of Radiology, Dong Guk University Medical Center, Seoul (Korea, Republic of); Park, Soon Cheol [Dept. of Radiology, Kang Dong Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2013-12-15

    This study was proven for the T-spine breathing technique in lateral projection, using computer radiography (CR), charge coupled device (CCD), indirect digital radiography (IDR) and direct digital radiography (DDR). All images were evaluated and compared with CNR and SNR measured with the mean pixels and the standard deviation as setting ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk using Image J. In experiment results of 4 type detectors, T-spine breathing technique was indicated as excellent in ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk. As T-spine breathing technique indicated excellent images compared to the existing T-spine lateral radiography, this method would be useful for elderly patients who have difficulty in deep exhalation. This study was indicated the application possibility of T-spine breathing technique by presenting contrast to noise ratio (CNR) and signal to noise ratio (SNR) with quantitative value in 4 type detectors.

  2. Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

    International Nuclear Information System (INIS)

    Xue, Zhenyu; Charonko, John J; Vlachos, Pavlos P

    2014-01-01

    In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we extend the original work by Charonko and Vlachos and present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. Several corrections have been applied in this work. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations by applying a subtraction of the minimum correlation value to remove the effect of the background image noise. In addition, the notion of a ‘valid’ measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an ‘outlier’ measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to more robust and reliable uncertainty estimation models compared with the original work by Charonko and Vlachos. The models are tested against both synthetic benchmark data as well as experimental measurements. In this work, U 68.5 uncertainties are estimated at the 68.5% confidence level while U 95 uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical confidence intervals, thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements. (paper)

  3. Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

    Science.gov (United States)

    Xue, Zhenyu; Charonko, John J.; Vlachos, Pavlos P.

    2014-11-01

    In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we extend the original work by Charonko and Vlachos and present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. Several corrections have been applied in this work. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations by applying a subtraction of the minimum correlation value to remove the effect of the background image noise. In addition, the notion of a ‘valid’ measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an ‘outlier’ measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to more robust and reliable uncertainty estimation models compared with the original work by Charonko and Vlachos. The models are tested against both synthetic benchmark data as well as experimental measurements. In this work, {{U}68.5} uncertainties are estimated at the 68.5% confidence level while {{U}95} uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical confidence intervals, thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements.

  4. Optimum SNR data compression in hardware using an Eigencoil array.

    Science.gov (United States)

    King, Scott B; Varosi, Steve M; Duensing, G Randy

    2010-05-01

    With the number of receivers available on clinical MRI systems now ranging from 8 to 32 channels, data compression methods are being explored to lessen the demands on the computer for data handling and processing. Although software-based methods of compression after reception lessen computational requirements, a hardware-based method before the receiver also reduces the number of receive channels required. An eight-channel Eigencoil array is constructed by placing a hardware radiofrequency signal combiner inline after preamplification, before the receiver system. The Eigencoil array produces signal-to-noise ratio (SNR) of an optimal reconstruction using a standard sum-of-squares reconstruction, with peripheral SNR gains of 30% over the standard array. The concept of "receiver channel reduction" or MRI data compression is demonstrated, with optimal SNR using only four channels, and with a three-channel Eigencoil, superior sum-of-squares SNR was achieved over the standard eight-channel array. A three-channel Eigencoil portion of a product neurovascular array confirms in vivo SNR performance and demonstrates parallel MRI up to R = 3. This SNR-preserving data compression method advantageously allows users of MRI systems with fewer receiver channels to achieve the SNR of higher-channel MRI systems. (c) 2010 Wiley-Liss, Inc.

  5. Combining parallel detection of proton echo planar spectroscopic imaging (PEPSI) measurements with a data-consistency constraint improves SNR.

    Science.gov (United States)

    Tsai, Shang-Yueh; Hsu, Yi-Cheng; Chu, Ying-Hua; Kuo, Wen-Jui; Lin, Fa-Hsuan

    2015-12-01

    One major challenge of MRSI is the poor signal-to-noise ratio (SNR), which can be improved by using a surface coil array. Here we propose to exploit the spatial sensitivity of different channels of a coil array to enforce the k-space data consistency (DC) in order to suppress noise and consequently to improve MRSI SNR. MRSI data were collected using a proton echo planar spectroscopic imaging (PEPSI) sequence at 3 T using a 32-channel coil array and were averaged with one, two and eight measurements (avg-1, avg-2 and avg-8). The DC constraint was applied using a regularization parameter λ of 1, 2, 3, 5 or 10. Metabolite concentrations were quantified using LCModel. Our results show that the suppression of noise by applying the DC constraint to PEPSI reconstruction yields up to 32% and 27% SNR gain for avg-1 and avg-2 data with λ = 5, respectively. According to the reported Cramer-Rao lower bounds, the improvement in metabolic fitting was significant (p < 0.01) when the DC constraint was applied with λ ≥ 2. Using the DC constraint with λ = 3 or 5 can minimize both root-mean-square errors and spatial variation for all subjects using the avg-8 data set as reference values. Our results suggest that MRSI reconstructed with a DC constraint can save around 70% of scanning time to obtain images and spectra with similar SNRs using λ = 5. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Free-space optical communications with peak and average constraints: High SNR capacity approximation

    KAUST Repository

    Chaaban, Anas; Morvan, Jean-Marie; Alouini, Mohamed-Slim

    2015-01-01

    . Numerical evaluation shows that this capacity lower bound is nearly tight at high signal-to-noise ratio (SNR), while it is shown analytically that the gap to capacity upper bounds is a small constant at high SNR. In particular, the gap to the high

  7. Signal-to-noise ratio of FT-IR CO gas spectra

    DEFF Research Database (Denmark)

    Bak, J.; Clausen, Sønnik

    1999-01-01

    in emission and transmission spectrometry, an investigation of the SNR in CO gas spectra as a function of spectral resolution has been carried out. We present a method to (1) determine experimentally the SNR at constant throughput, (2) determine the SNR on the basis of measured noise levels and Hitran......The minimum amount of a gaseous compound which can be detected and quantified with Fourier transform infrared (FT-IR) spectrometers depends on the signal-to-noise ratio (SNR) of the measured gas spectra. In order to use low-resolution FT-IR spectrometers to measure combustion gases like CO and CO2...... simulated signals, and (3) determine the SNR of CO from high to low spectral resolutions related to the molecular linewidth and vibrational-rotational lines spacing. In addition, SNR values representing different spectral resolutions but scaled to equal measurement times were compared. It was found...

  8. Empirical investigation on the dependence of TCP downstream throughput on SNR in an IEEE802.11b WLAN system

    Directory of Open Access Journals (Sweden)

    Ikponmwosa Oghogho

    2017-04-01

    Full Text Available The dependence of TCP downstream throughput (TCPdownT on signal to noise ratio (SNR in an IEEE802.11b WLAN system was investigated in various environments and varieties of QoS traffic. TCPdownT was measured for various SNR observed. An Infrastructure based IEEE802.11b WLAN system having networked computers on which measurement software were installed, was set up consecutively in various environments (open corridor, small offices with block walls and plaster boards and free space. Empirical models describing TCPdownT against SNR for different signal ranges (all ranges of signals, strong signals only, grey signals only and weak signals only were statistically generated and validated. As the SNR values changed from high (strong signals through low (grey signals to very low (weak signals, our results show a strong dependence of TCPdownT on the received SNR. Our models showed lower RMS errors when compared with other similar models. We observed RMS errors of 0.6734791 Mbps, 0.472209 Mbps, 0.9111563 Mbps and 0.5764460 Mbps for general (all SNR model, strong signals model, grey signals model and Weak signals model respectively. Our models will provide researchers and WLAN systems users with a tool to estimate the TCP downstream throughput in a real network in various environments by monitoring the received SNR.

  9. A method to design high SNR nanoscale magnetic sensors using an array of tunnelling magneto-resistance (TMR) devices

    International Nuclear Information System (INIS)

    Gomez, P; Litvinov, D; Khizroev, S

    2007-01-01

    This paper presents a systematic method to design and calculate tunnelling magneto-resistance (TMR) sensors with high signal-to-noise ratio (SNR). The sensing module consists of four TMR devices arranged in a Wheatstone-bridge configuration. Closed-form equations were obtained to calculate TMR sensor current, array output voltage, magneto-resistance ratio, overall noise (thermal and shot) and SNR for a given bandwidth. Using this technique we were able to maximize the SNR by tuning the many parameters of the TMR devices. Typical SNR values are in excess of 45 dB

  10. Evaluation and comparison of contrast to noise ratio and signal to noise ratio according to change of reconstruction on breast PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Jae [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); Lee, Eul Kyu [Dept. of Radiology, Inje Paik University Hospital Jeo-dong, Seoul (Korea, Republic of); Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, The Baekseok Culture University, Cheonan (Korea, Republic of); Lyu, Kwang Yeul; Park, Hoon Hee; Son, Jin Hyun; Min, Jung Whan [Dept. of Radiological Technology, The Shingu University, Sungnam (Korea, Republic of)

    2017-03-15

    The purpose of this study was to measure contrast to noise ratio (CNR) and signal to noise ratio (SNR) according to change of reconstruction from region of interest (ROI) in breast positron emission tomography- computed tomography (PET-CT), and to analyze the CNR and SNR statically. We examined images of breast PET-CT of 100 patients in a University-affiliated hospital, Seoul, Korea. Each patient's image of breast PET-CT were calculated by using Image J. Differences of CNR and SNR among four reconstruction algorithms were tested by SPSS Statistics21 ANOVA test for there was statistical significance (p<0.05). We have analysis socio-demographical variables, CNR and SNR according to reconstruction images, 95% confidence according to CNR and SNR of reconstruction and difference in a mean of CNR and SNR. SNR results, with the quality of distributions in the order of PSF{sub T}OF, Iterative and Iterative-TOF, FBP-TOF. CNR, with the quality of distributions in the order of PSF{sub T}OF, Iterative and Iterative-TOF, FBP-TOF. CNR and SNR of PET-CT reconstruction methods of the breast would be useful to evaluate breast diseases.

  11. Selective Route Based on SNR with Cross-Layer Scheme in Wireless Ad Hoc Network

    Directory of Open Access Journals (Sweden)

    Istikmal

    2017-01-01

    Full Text Available In this study, we developed network and throughput formulation models and proposed new method of the routing protocol algorithm with a cross-layer scheme based on signal-to-noise ratio (SNR. This method is an enhancement of routing protocol ad hoc on-demand distance vector (AODV. This proposed scheme uses selective route based on the SNR threshold in the reverse route mechanism. We developed AODV SNR-selective route (AODV SNR-SR for a mechanism better than AODV SNR, that is, the routing protocol that used average or sum of path SNR, and also better than AODV which is hop-count-based. We also used selective reverse route based on SNR mechanism, replacing the earlier method to avoid routing overhead. The simulation results show that AODV SNR-SR outperforms AODV SNR and AODV in terms of throughput, end-to-end delay, and routing overhead. This proposed method is expected to support Device-to-Device (D2D communications that are concerned with the quality of the channel awareness in the development of the future Fifth Generation (5G.

  12. Using optical fibers with different modes to improve the signal-to-noise ratio of diffuse correlation spectroscopy flow-oximeter measurements

    Science.gov (United States)

    He, Lian; Lin, Yu; Shang, Yu; Shelton, Brent J.; Yu, Guoqiang

    2013-03-01

    The dual-wavelength diffuse correlation spectroscopy (DCS) flow-oximeter is an emerging technique enabling simultaneous measurements of blood flow and blood oxygenation changes in deep tissues. High signal-to-noise ratio (SNR) is crucial when applying DCS technologies in the study of human tissues where the detected signals are usually very weak. In this study, single-mode, few-mode, and multimode fibers are compared to explore the possibility of improving the SNR of DCS flow-oximeter measurements. Experiments on liquid phantom solutions and in vivo muscle tissues show only slight improvements in flow measurements when using the few-mode fiber compared with using the single-mode fiber. However, light intensities detected by the few-mode and multimode fibers are increased, leading to significant SNR improvements in detections of phantom optical property and tissue blood oxygenation. The outcomes from this study provide useful guidance for the selection of optical fibers to improve DCS flow-oximeter measurements.

  13. Free-space optical communications with peak and average constraints: High SNR capacity approximation

    KAUST Repository

    Chaaban, Anas

    2015-09-07

    The capacity of the intensity-modulation direct-detection (IM-DD) free-space optical channel with both average and peak intensity constraints is studied. A new capacity lower bound is derived by using a truncated-Gaussian input distribution. Numerical evaluation shows that this capacity lower bound is nearly tight at high signal-to-noise ratio (SNR), while it is shown analytically that the gap to capacity upper bounds is a small constant at high SNR. In particular, the gap to the high-SNR asymptotic capacity of the channel under either a peak or an average constraint is small. This leads to a simple approximation of the high SNR capacity. Additionally, a new capacity upper bound is derived using sphere-packing arguments. This bound is tight at high SNR for a channel with a dominant peak constraint.

  14. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinzhen; Li, Gang; Lin, Ling, E-mail: linling@tju.edu.cn [State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People' s Republic of China, and Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin (China); Qiao, Xiaoyan [College of Physics and Electronic Engineering, Shanxi University, Shanxi (China); Wang, Mengjun [School of Information Engineering, Hebei University of Technology, Tianjin (China); Zhang, Weibo [Institute of Acupuncture and Moxibustion China Academy of Chinese Medical Sciences, Beijing (China)

    2014-05-15

    The stability and signal to noise ratio (SNR) of the current source circuit are the important factors contributing to enhance the accuracy and sensitivity in bioimpedance measurement system. In this paper we propose a new differential Howland topology current source and evaluate its output characters by simulation and actual measurement. The results include (1) the output current and impedance in high frequencies are stabilized after compensation methods. And the stability of output current in the differential current source circuit (DCSC) is 0.2%. (2) The output impedance of two current circuits below the frequency of 200 KHz is above 1 MΩ, and below 1 MHz the output impedance can arrive to 200 KΩ. Then in total the output impedance of the DCSC is higher than that of the Howland current source circuit (HCSC). (3) The SNR of the DCSC are 85.64 dB and 65 dB in the simulation and actual measurement with 10 KHz, which illustrates that the DCSC effectively eliminates the common mode interference. (4) The maximum load in the DCSC is twice as much as that of the HCSC. Lastly a two-dimensional phantom electrical impedance tomography is well reconstructed with the proposed HCSC. Therefore, the measured performance shows that the DCSC can significantly improve the output impedance, the stability, the maximum load, and the SNR of the measurement system.

  15. High SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging

    Science.gov (United States)

    Motosugi, Utaroh; Hernando, Diego; Wiens, Curtis; Bannas, Peter; Reeder, Scott. B

    2017-01-01

    Purpose: To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). Materials and Methods: Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the same scans were repeated to evaluate the test-retest repeatability. Next, an in vivo study was performed with 20 volunteers and 28 patients scheduled for liver magnetic resonance imaging (MRI). Two CSE-MRI protocols with standard- and high-SNR were repeated to assess test-retest repeatability. MR spectroscopy (MRS)-based PDFF was acquired as a standard of reference. The standard deviation (SD) of the difference (Δ) of PDFF measured in the two repeated scans was defined to ascertain repeatability. The correlation between PDFF of CSE-MRI and MRS was calculated to assess accuracy. The SD of Δ and correlation coefficients of the two protocols (standard- and high-SNR) were compared using F-test and t-test, respectively. Two reconstruction algorithms (complex-based and magnitude-based) were used for both the phantom and in vivo experiments. Results: The phantom study demonstrated that higher SNR improved the repeatability for both complex- and magnitude-based reconstruction. Similarly, the in vivo study demonstrated that the repeatability of the high-SNR protocol (SD of Δ = 0.53 for complex- and = 0.85 for magnitude-based fit) was significantly higher than using the standard-SNR protocol (0.77 for complex, P magnitude-based fit, P = 0.003). No significant difference was observed in the accuracy between standard- and high-SNR protocols. Conclusion: Higher SNR improves the repeatability of fat quantification using confounder-corrected CSE-MRI. PMID:28190853

  16. A Family of Maximum SNR Filters for Noise Reduction

    DEFF Research Database (Denmark)

    Huang, Gongping; Benesty, Jacob; Long, Tao

    2014-01-01

    significantly increase the SNR but at the expense of tremendous speech distortion. As a consequence, the speech quality improvement, measured by the perceptual evaluation of speech quality (PESQ) algorithm, is marginal if any, regardless of the number of microphones used. In the STFT domain, the maximum SNR...

  17. A CLT on the SNR of Diagonally Loaded MVDR Filters

    Science.gov (United States)

    Rubio, Francisco; Mestre, Xavier; Hachem, Walid

    2012-08-01

    This paper studies the fluctuations of the signal-to-noise ratio (SNR) of minimum variance distorsionless response (MVDR) filters implementing diagonal loading in the estimation of the covariance matrix. Previous results in the signal processing literature are generalized and extended by considering both spatially as well as temporarily correlated samples. Specifically, a central limit theorem (CLT) is established for the fluctuations of the SNR of the diagonally loaded MVDR filter, under both supervised and unsupervised training settings in adaptive filtering applications. Our second-order analysis is based on the Nash-Poincar\\'e inequality and the integration by parts formula for Gaussian functionals, as well as classical tools from statistical asymptotic theory. Numerical evaluations validating the accuracy of the CLT confirm the asymptotic Gaussianity of the fluctuations of the SNR of the MVDR filter.

  18. Secure diversity-multiplexing tradeoff of zero-forcing transmit scheme at finite-SNR

    KAUST Repository

    Rezki, Zouheir

    2012-04-01

    In this paper, we address the finite Signal-to-Noise Ratio (SNR) Diversity-Multiplexing Tradeoff (DMT) of the Multiple Input Multiple Output (MIMO) wiretap channel, where a Zero-Forcing (ZF) transmit scheme, that intends to send the secret information in the orthogonal space of the eavesdropper channel, is used. First, we introduce the secrecy multiplexing gain at finite-SNR that generalizes the definition at high-SNR. Then, we provide upper and lower bounds on the outage probability under secrecy constraint, from which secrecy diversity gain estimates of ZF are derived. Through asymptotic analysis, we show that the upper bound underestimates the secrecy diversity gain, whereas the lower bound is tight at high-SNR, and thus its related diversity gain estimate is equal to the actual asymptotic secrecy diversity gain of the MIMO wiretap channel. © 2012 IEEE.

  19. Weighted-SNR-based fair scheduling for uplink OFDMA

    KAUST Repository

    Ma, Yao

    2009-11-01

    In this paper, we study the sum rate maximization algorithms with long-term proportional rate fairness (PRF) for uplink orthogonal frequency division multiple access (OFDMA) systems. In contrast to the rate-maximization schemes which used short-term PRF in the literature, we propose to use a selective multiuser diversity (SMuD) scheme to achieve a long-term PRF and improved sum rate performance. This scheme implements weighted channel signal-to-noise ratio (w-SNR)-based ranking for user selection on each subchannel, and then uses either water-filling (WF) or equal power allocation (EPA) along the assigned channels of each user. Both offline and online methods to find the optimal SNR weight factors are designed to achieve the target proportional rates for different users. The offline optimization technique requires to know the channel distribution information (CDI) at the scheduler. The online method uses the weight adaption combined with individual user rate tracking, which avoids the need to know the CDI. Analytical throughput metrics for the proposed w-SNR scheme with WF and EPA over Rayleigh channels are derived, and verified by simulations. Simulation results show that the proposed w-SNR PRF scheme can achieve significantly higher sum rates than the frequency diversity-based short-term and long-term fairness schemes. Besides the improved performance, the proposed schemes have a low complexity which is linear to numbers of users and subchannels.

  20. Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors.

    Science.gov (United States)

    Willis, Charles E; Vinogradskiy, Yevgeniy Y; Lofton, Brad K; White, R Allen

    2011-07-01

    The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 microGy air KERMA) to the detector. The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r2=0.9999). The dependence was greater than unity (m = 1.101 +/- 0.006), and the difference from unity was statistically significant (p grid replacement. The nonconformant behavior of the other system was corrected by replacing

  1. On the low SNR capacity of log-normal turbulence channels with full CSI

    KAUST Repository

    Benkhelifa, Fatma; Tall, Abdoulaye; Rezki, Zouheir; Alouini, Mohamed-Slim

    2014-01-01

    In this paper, we characterize the low signal-To-noise ratio (SNR) capacity of wireless links undergoing the log-normal turbulence when the channel state information (CSI) is perfectly known at both the transmitter and the receiver. We derive a closed form asymptotic expression of the capacity and we show that it scales essentially as λ SNR where λ is the water-filling level satisfying the power constraint. An asymptotically closed-form expression of λ is also provided. Using this framework, we also propose an on-off power control scheme which is capacity-achieving in the low SNR regime.

  2. On the low SNR capacity of log-normal turbulence channels with full CSI

    KAUST Repository

    Benkhelifa, Fatma

    2014-09-01

    In this paper, we characterize the low signal-To-noise ratio (SNR) capacity of wireless links undergoing the log-normal turbulence when the channel state information (CSI) is perfectly known at both the transmitter and the receiver. We derive a closed form asymptotic expression of the capacity and we show that it scales essentially as λ SNR where λ is the water-filling level satisfying the power constraint. An asymptotically closed-form expression of λ is also provided. Using this framework, we also propose an on-off power control scheme which is capacity-achieving in the low SNR regime.

  3. Evaluation of the signal-to-noise ratio (SNR) in a CR system and establishment of RQR-M and RQA-M IEC reference radiations in mammography

    International Nuclear Information System (INIS)

    Rosado, Paulo H.G.; Nogueira, Maria S.; Dantas, Marcelino V.A.; Santana, Priscila do C.

    2009-01-01

    In this work, the radiation condition RQR-M e RQA-M of IEC were established in the Siemens Mammomat 3000 mammography equipment. The standard radiation condition are described in terms of: emitting target of molybdenum, percentage ripple not more that 4%, total filtration of 0,032 ± 0,002 mm of molybdenum and specific values of first half-value layer. The results show that the values of parameters were in the range that the IEC recommends. Only the RQAM-3 the value of CSR was not in agreement of the value recommend, and was necessary a additions of 0,1 mm Al in the x-ray tube. After this, the signal noise ratio (SNR) of de Computer radiography (CR) system was evaluated in the reference qualities of RQR-M e RQA-M. For SNR the RQR-M mode of exposure was done with both the 20 mAs and automatic one. To RQA-M the exposure was done with 100 mAs. The variations of the values of SNR were approximated 4%. The tests were done with CR model CR850 made from Kodak and 40 mm of PMMA. (author)

  4. SNR Estimation in Linear Systems with Gaussian Matrices

    KAUST Repository

    Suliman, Mohamed Abdalla Elhag; Alrashdi, Ayed; Ballal, Tarig; Al-Naffouri, Tareq Y.

    2017-01-01

    This letter proposes a highly accurate algorithm to estimate the signal-to-noise ratio (SNR) for a linear system from a single realization of the received signal. We assume that the linear system has a Gaussian matrix with one sided left correlation. The unknown entries of the signal and the noise are assumed to be independent and identically distributed with zero mean and can be drawn from any distribution. We use the ridge regression function of this linear model in company with tools and techniques adapted from random matrix theory to achieve, in closed form, accurate estimation of the SNR without prior statistical knowledge on the signal or the noise. Simulation results show that the proposed method is very accurate.

  5. SNR Estimation in Linear Systems with Gaussian Matrices

    KAUST Repository

    Suliman, Mohamed Abdalla Elhag

    2017-09-27

    This letter proposes a highly accurate algorithm to estimate the signal-to-noise ratio (SNR) for a linear system from a single realization of the received signal. We assume that the linear system has a Gaussian matrix with one sided left correlation. The unknown entries of the signal and the noise are assumed to be independent and identically distributed with zero mean and can be drawn from any distribution. We use the ridge regression function of this linear model in company with tools and techniques adapted from random matrix theory to achieve, in closed form, accurate estimation of the SNR without prior statistical knowledge on the signal or the noise. Simulation results show that the proposed method is very accurate.

  6. SNR and Standard Deviation of cGNSS-R and iGNSS-R Scatterometric Measurements.

    Science.gov (United States)

    Alonso-Arroyo, Alberto; Querol, Jorge; Lopez-Martinez, Carlos; Zavorotny, Valery U; Park, Hyuk; Pascual, Daniel; Onrubia, Raul; Camps, Adriano

    2017-01-19

    This work addresses the accuracy of the Global Navigation Satellite Systems (GNSS)-Reflectometry (GNSS-R) scatterometric measurements considering the presence of both coherent and incoherent scattered components, for both conventional GNSS-R (cGNSS-R) and interferometric GNSS-R (iGNSS-R) techniques. The coherent component is present for some type of surfaces, and it has been neglected until now because it vanishes for the sea surface scattering case. Taking into account the presence of both scattering components, the estimated Signal-to-Noise Ratio (SNR) for both techniques is computed based on the detectability criterion, as it is done in conventional GNSS applications. The non-coherent averaging operation is considered from a general point of view, taking into account that thermal noise contributions can be reduced by an extra factor of 0.88 dB when using partially overlapped or partially correlated samples. After the SNRs are derived, the received waveform's peak variability is computed, which determines the system's capability to measure geophysical parameters. This theoretical derivations are applied to the United Kingdom (UK) TechDemoSat-1 (UK TDS-1) and to the future GNSS REflectometry, Radio Occultation and Scatterometry on board the International Space Station (ISS) (GEROS-ISS) scenarios, in order to estimate the expected scatterometric performance of both missions.

  7. Statistical approach of measurement of signal to noise ratio in according to change pulse sequence on brain MRI meningioma and cyst images

    International Nuclear Information System (INIS)

    Lee, Eul Kyu; Choi, Kwan Woo; Jeong, Hoi Woun; Jang, Seo Goo; Kim, Ki Won; Son, Soon Yong; Min, Jung Whan; Son, Jin Hyun

    2016-01-01

    The purpose of this study was to needed basis of measure MRI CAD development for signal to noise ratio (SNR) by pulse sequence analysis from region of interest (ROI) in brain magnetic resonance imaging (MRI) contrast. We examined images of brain MRI contrast enhancement of 117 patients, from January 2005 to December 2015 in a University-affiliated hospital, Seoul, Korea. Diagnosed as one of two brain diseases such as meningioma and cysts SNR for each patient's image of brain MRI were calculated by using Image J. Differences of SNR among two brain diseases were tested by SPSS Statistics21 ANOVA test for there was statistical significance (p < 0.05). We have analysis socio-demographical variables, SNR according to sequence disease, 95% confidence according to SNR of sequence and difference in a mean of SNR. Meningioma results, with the quality of distributions in the order of T1CE, T2 and T1, FLAIR. Cysts results, with the quality of distributions in the order of T2 and T1, T1CE and FLAIR. SNR of MRI sequences of the brain would be useful to classify disease. Therefore, this study will contribute to evaluate brain diseases, and be a fundamental to enhancing the accuracy of CAD development

  8. Statistical approach of measurement of signal to noise ratio in according to change pulse sequence on brain MRI meningioma and cyst images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eul Kyu [Inje Paik University Hospital Jeo-dong, Seoul (Korea, Republic of); Choi, Kwan Woo [Asan Medical Center, Seoul (Korea, Republic of); Jeong, Hoi Woun [The Baekseok Culture University, Cheonan (Korea, Republic of); Jang, Seo Goo [The Soonchunhyang University, Asan (Korea, Republic of); Kim, Ki Won [Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Son, Soon Yong [The Wonkwang Health Science University, Iksan (Korea, Republic of); Min, Jung Whan; Son, Jin Hyun [The Shingu University, Sungnam (Korea, Republic of)

    2016-09-15

    The purpose of this study was to needed basis of measure MRI CAD development for signal to noise ratio (SNR) by pulse sequence analysis from region of interest (ROI) in brain magnetic resonance imaging (MRI) contrast. We examined images of brain MRI contrast enhancement of 117 patients, from January 2005 to December 2015 in a University-affiliated hospital, Seoul, Korea. Diagnosed as one of two brain diseases such as meningioma and cysts SNR for each patient's image of brain MRI were calculated by using Image J. Differences of SNR among two brain diseases were tested by SPSS Statistics21 ANOVA test for there was statistical significance (p < 0.05). We have analysis socio-demographical variables, SNR according to sequence disease, 95% confidence according to SNR of sequence and difference in a mean of SNR. Meningioma results, with the quality of distributions in the order of T1CE, T2 and T1, FLAIR. Cysts results, with the quality of distributions in the order of T2 and T1, T1CE and FLAIR. SNR of MRI sequences of the brain would be useful to classify disease. Therefore, this study will contribute to evaluate brain diseases, and be a fundamental to enhancing the accuracy of CAD development.

  9. Low SNR Capacity of FSO Links over Gamma-Gamma Atmospheric Turbulence Channels

    KAUST Repository

    Benkhelifa, Fatma; Alouini, Mohamed-Slim; Rezki, Zouheir

    2013-01-01

    free space optical communication systems over Gamma-Gamma atmospheric turbulence fading channels with perfect channel state information at both the transmitter and the receiver. In our framework, we mainly focus on the low signal-to-noise ratio range and show that the ergodic capacity scales proportionally to SNR log^4(1/SNR). We show also that one-bit CSI feedback at the transmitter is enough to achieve this capacity using an on-o ff power control scheme.

  10. Analysis on frequency response of trans-impedance amplifier (TIA) for signal-to-noise ratio (SNR) enhancement in optical signal detection system using lock-in amplifier (LIA)

    Science.gov (United States)

    Kim, Ji-Hoon; Jeon, Su-Jin; Ji, Myung-Gi; Park, Jun-Hee; Choi, Young-Wan

    2017-02-01

    Lock-in amplifier (LIA) has been widely used in optical signal detection systems because it can measure small signal under high noise level. Generally, The LIA used in optical signal detection system is composed of transimpedance amplifier (TIA), phase sensitive detector (PSD) and low pass filter (LPF). But commercial LIA using LPF is affected by flicker noise. To avoid flicker noise, there is 2ω detection LIA using BPF. To improve the dynamic reserve (DR) of the 2ω LIA, the signal to noise ratio (SNR) of the TIA should be improved. According to the analysis of frequency response of the TIA, the noise gain can be minimized by proper choices of input capacitor (Ci) and feed-back network in the TIA in a specific frequency range. In this work, we have studied how the SNR of the TIA can be improved by a proper choice of frequency range. We have analyzed the way to control this frequency range through the change of passive component in the TIA. The result shows that the variance of the passive component in the TIA can change the specific frequency range where the noise gain is minimized in the uniform gain region of the TIA.

  11. Design of an adaptive CubeSat transmitter for achieving optimum signal-to-noise ratio (SNR)

    Science.gov (United States)

    Jaswar, F. D.; Rahman, T. A.; Hindia, M. N.; Ahmad, Y. A.

    2017-12-01

    CubeSat technology has opened the opportunity to conduct space-related researches at a relatively low cost. Typical approach to maintain an affordable cubeSat mission is to use a simple communication system, which is based on UHF link with fixed-transmit power and data rate. However, CubeSat in the Low Earth Orbit (LEO) does not have relative motion with the earth rotation, resulting in variable propagation path length that affects the transmission signal. A transmitter with adaptive capability to select multiple sets of data rate and radio frequency (RF) transmit power is proposed to improve and optimise the link. This paper presents the adaptive UHF transmitter design as a solution to overcome the variability of the propagation path. The transmitter output power is adjustable from 0.5W to 2W according to the mode of operations and satellite power limitations. The transmitter is designed to have four selectable modes to achieve the optimum signal-to-noise ratio (SNR) and efficient power consumption based on the link budget analysis and satellite requirement. Three prototypes are developed and tested for space-environment conditions such as the radiation test. The Total Ionizing Dose measurements are conducted in the radiation test done at Malaysia Nuclear Agency Laboratory. The results from this test have proven that the adaptive transmitter can perform its operation with estimated more than seven months in orbit. This radiation test using gamma source with 1.5krad exposure is the first one conducted for a satellite program in Malaysia.

  12. How to improve a critical performance for an ExoMars 2020 Scientific Instrument (RLS). Raman Laser Spectrometer Signal to Noise Ratio (SNR) Optimization

    Science.gov (United States)

    Canora, C. P.; Moral, A. G.; Rull, F.; Maurice, S.; Hutchinson, I.; Ramos, G.; López-Reyes, G.; Belenguer, T.; Canchal, R.; Prieto, J. A. R.; Rodriguez, P.; Santamaria, P.; Berrocal, A.; Colombo, M.; Gallago, P.; Seoane, L.; Quintana, C.; Ibarmia, S.; Zafra, J.; Saiz, J.; Santiago, A.; Marin, A.; Gordillo, C.; Escribano, D.; Sanz-Palominoa, M.

    2017-09-01

    The Raman Laser Spectrometer (RLS) is one of the Pasteur Payload instruments, within the ESA's Aurora Exploration Programme, ExoMars mission. Raman spectroscopy is based on the analysis of spectral fingerprints due to the inelastic scattering of light when interacting with matter. RLS is composed by Units: SPU (Spectrometer Unit), iOH (Internal Optical Head), and ICEU (Instrument Control and Excitation Unit) and the harnesses (EH and OH). The iOH focuses the excitation laser on the samples and collects the Raman emission from the sample via SPU (CCD) and the video data (analog) is received, digitalizing it and transmiting it to the processor module (ICEU). The main sources of noise arise from the sample, the background, and the instrument (Laser, CCD, focuss, acquisition parameters, operation control). In this last case the sources are mainly perturbations from the optics, dark signal and readout noise. Also flicker noise arising from laser emission fluctuations can be considered as instrument noise. In order to evaluate the SNR of a Raman instrument in a practical manner it is useful to perform end-to-end measurements on given standards samples. These measurements have to be compared with radiometric simulations using Raman efficiency values from literature and taking into account the different instrumental contributions to the SNR. The RLS EQM instrument performances results and its functionalities have been demonstrated in accordance with the science expectations. The Instrument obtained SNR performances in the RLS EQM will be compared experimentally and via analysis, with the Instrument Radiometric Model tool. The characterization process for SNR optimization is still on going. The operational parameters and RLS algorithms (fluorescence removal and acquisition parameters estimation) will be improved in future models (EQM-2) until FM Model delivery.

  13. Low SNR Capacity of FSO Links over Gamma-Gamma Atmospheric Turbulence Channels

    KAUST Repository

    Benkhelifa, Fatma

    2013-01-27

    In this paper, we study the ergodic capacity of free space optical communication systems over Gamma-Gamma atmospheric turbulence fading channels with perfect channel state information at both the transmitter and the receiver. In our framework, we mainly focus on the low signal-to-noise ratio range and show that the ergodic capacity scales proportionally to SNR log^4(1/SNR). We show also that one-bit CSI feedback at the transmitter is enough to achieve this capacity using an on-o ff power control scheme.

  14. Low SNR Capacity of FSO Links over Gamma-Gamma Atmospheric Turbulence Channels

    KAUST Repository

    Benkhelifa, Fatma

    2013-02-23

    In this paper, we study the ergodic capacity of free space optical communication systems over Gamma-Gamma atmospheric turbulence fading channels with perfect channel state information at both the transmitter and the receiver. In our framework, we mainly focus on the low signal-to-noise ratio range and show that the ergodic capacity scales proportionally to SNR log^4(1/SNR). We show also that one-bit CSI feedback at the transmitter is enough to achieve this capacity using an on-off power control scheme.

  15. Low SNR Capacity of FSO Links over Gamma-Gamma Atmospheric Turbulence Channels

    KAUST Repository

    Benkhelifa, Fatma; Alouini, Mohamed-Slim; Rezki, Zouheir

    2013-01-01

    In this paper, we study the ergodic capacity of free space optical communication systems over Gamma-Gamma atmospheric turbulence fading channels with perfect channel state information at both the transmitter and the receiver. In our framework, we mainly focus on the low signal-to-noise ratio range and show that the ergodic capacity scales proportionally to SNR log^4(1/SNR). We show also that one-bit CSI feedback at the transmitter is enough to achieve this capacity using an on-off power control scheme.

  16. The upper limits of the SNR in radiography and CT with polyenergetic x-rays

    International Nuclear Information System (INIS)

    Shikhaliev, Polad M

    2010-01-01

    The aim of the study is to determine the upper limits of the signal-to-noise ratio (SNR) in radiography and computed tomography (CT) with polyenergetic x-ray sources. In x-ray imaging, monoenergetic x-rays provide a higher SNR compared to polyenergetic x-rays. However, the SNR in polyenergetic x-ray imaging can be increased when a photon-counting detector is used and x-rays are optimally weighted according to their energies. For a particular contrast/background combination and at a fixed x-ray entrance skin exposure, the SNR in energy-weighting x-ray imaging depends on tube voltage and can be maximized by selecting the optimal tube voltage. The SNR in energy-weighted x-ray images acquired at this optimal tube voltage is the highest SNR that can be achieved with polyenergetic x-ray sources. The optimal tube voltages and the highest SNR were calculated and compared to the SNR of monoenergetic x-ray imaging. Monoenergetic, energy-weighting polyenergetic and energy-integrating polyenergetic x-ray imagings were simulated at a fixed entrance skin exposure of 20 mR. The tube voltages varied in the range of 30-140 kVp with 10 kV steps. Contrast elements of CaCO 3 , iodine, adipose and tumor with thicknesses of 280 mg cm -2 , 15 mg cm -2 , 1 g cm -2 and 1 g cm -2 , respectively, inserted in a soft tissue background with 10 cm and 20 cm thicknesses, were used. The energy weighting also improves the contrast-to-noise ratio (CNR) in CT when monoenergetic CT projections are optimally weighted prior to CT reconstruction (projection-based weighting). Alternatively, monoenergetic CT images are reconstructed, optimally weighted and composed to yield a final CT image (image-based weighting). Both projection-based and image-based weighting methods improve the CNR in CT. An analytical approach was used to determine which of these two weighting methods provides the upper limit of the CNR in CT. The energy-weighting method was generalized and expanded as a weighting method applicable in

  17. The effect of energy weighting on the SNR under the influence of non-ideal detectors in mammographic applications

    International Nuclear Information System (INIS)

    Patatoukas, G.; Gaitanis, A.; Kalivas, N.; Liaparinos, P.; Nikolopoulos, D.; Konstantinidis, A.; Kandarakis, I.; Cavouras, D.; Panayiotakis, G.

    2006-01-01

    This work investigates the effect of the energy-weighting technique on the signal to noise ratio (SNR) response of X-ray imaging detectors. So far in the literature all scintillation-detector characteristics (detection efficiency, conversion efficiency, light-attenuation effects, etc) that degrade image quality have been ignored. A theoretical evaluation of the scintillator's SNR output was carried out. An algorithm was produced to describe the variation of the weighting factor, and SNR, with respect to the anode material (Mo or W), in a particular energy range (25-40 keV), typical for mammography, using two different phantoms. Results show that under non-ideal conditions the ratio of the weighted SNR to the original SNR appears to be increasing from values that are close to unity, and under specific conditions, can reach values up to 30. For the further investigation of this method, a more complex, simulated computed tomography breast imaging system was modeled and studied for various parameters such as breast software phantoms, scintillation materials and reconstruction filters

  18. SNR and Standard Deviation of cGNSS-R and iGNSS-R Scatterometric Measurements

    Directory of Open Access Journals (Sweden)

    Alberto Alonso-Arroyo

    2017-01-01

    Full Text Available This work addresses the accuracy of the Global Navigation Satellite Systems (GNSS-Reflectometry (GNSS-R scatterometric measurements considering the presence of both coherent and incoherent scattered components, for both conventional GNSS-R (cGNSS-R and interferometric GNSS-R (iGNSS-R techniques. The coherent component is present for some type of surfaces, and it has been neglected until now because it vanishes for the sea surface scattering case. Taking into account the presence of both scattering components, the estimated Signal-to-Noise Ratio (SNR for both techniques is computed based on the detectability criterion, as it is done in conventional GNSS applications. The non-coherent averaging operation is considered from a general point of view, taking into account that thermal noise contributions can be reduced by an extra factor of 0.88 dB when using partially overlapped or partially correlated samples. After the SNRs are derived, the received waveform’s peak variability is computed, which determines the system’s capability to measure geophysical parameters. This theoretical derivations are applied to the United Kingdom (UK TechDemoSat-1 (UK TDS-1 and to the future GNSS REflectometry, Radio Occultation and Scatterometry on board the International Space Station (ISS (GEROS-ISS scenarios, in order to estimate the expected scatterometric performance of both missions.

  19. On the low SNR capacity of MIMO fading channels with imperfect channel state information

    KAUST Repository

    Benkhelifa, Fatma

    2014-06-01

    The capacity of multiple-input multiple-output (MIMO) Rayleigh fading channels with full knowledge of channel state information (CSI) at both the transmitter and the receiver (CSI-TR) has been shown recently to scale at low signal-to-noise ratio (SNR) essentially as SNR log(1/SNR), independently of the number of transmit and receive antennas. In this paper, we investigate the ergodic capacity of MIMO Rayleigh fading channel with estimated channel state information at the transmitter (CSI-T) and possibly imperfect channel state information at the receiver (CSI-R). Our framework can be seen as a generalization of previous works as it can capture the perfect CSI-TR as a special case when the estimation error variance goes to zero. In this paper, we mainly focus on the low SNR regime, and we show that the capacity scales as (1-α) SNR log(1/SNR), where α is the estimation error variance. This characterization shows the loss of performance due to error estimation over the perfect channel state information at both the transmitter and the receiver. As a by-product of our new analysis, we show that our framework can be also extended to characterize the capacity of MIMO Rician fading channels at low SNR with possibly imperfect CSI-T and CSI-R. © 1972-2012 IEEE.

  20. On the low SNR capacity of MIMO fading channels with imperfect channel state information

    KAUST Repository

    Benkhelifa, Fatma

    2014-05-01

    The capacity of Multiple Input Multiple Output (MIMO) Rayleigh fading channels with full knowledge of channel state information (CSI) at both the transmitter and the receiver (CSI-TR) has been shown recently to scale at low Signal-to-Noise Ratio (SNR) essentially as SNR log(1=SNR), independently of the number of transmit and receive antennas. In this paper, we investigate the ergodic capacity of MIMO Rayleigh fading channel with estimated channel state information at the transmitter (CSI-T) and possibly imperfect channel state information at the receiver (CSI-R). Our framework can be seen as a generalization of previous works as it can capture the perfect CSI-TR as a special case when the estimation error variance goes to zero. In our work, we mainly focus on the low SNR regime and we show that the capacity scales as (1-α) SNR log(1=SNR), where α is the estimation error variance. This characterization shows the loss of performance due to error estimation over the perfect channel state information at both the transmitter and the receiver. As a by-product of our new analysis, we show that our framework can also be extended to characterize the capacity of MIMO Rician fading channels at low SNR with possibly imperfect CSI-T and CSI-R. © 2014 IFIP.

  1. Improved method for SNR prediction in machine-learning-based test

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2010-01-01

    This paper applies an improved method for testing the signal-to-noise ratio (SNR) of Analogue-to-Digital Converters (ADC). In previous work, a noisy and nonlinear pulse signal is exploited as the input stimulus to obtain the signature results of ADC. By applying a machine-learning-based approach,

  2. Optimized filtering of regional and teleseismic seismograms: results of maximizing SNR measurements from the wavelet transform and filter banks

    Energy Technology Data Exchange (ETDEWEB)

    Leach, R.R.; Schultz, C.; Dowla, F.

    1997-07-15

    Development of a worldwide network to monitor seismic activity requires deployment of seismic sensors in areas which have not been well studied or may have from available recordings. Development and testing of detection and discrimination algorithms requires a robust representative set of calibrated seismic events for a given region. Utilizing events with poor signal-to-noise (SNR) can add significant numbers to usable data sets, but these events must first be adequately filtered. Source and path effects can make this a difficult task as filtering demands are highly varied as a function of distance, event magnitude, bearing, depth etc. For a given region, conventional methods of filter selection can be quite subjective and may require intensive analysis of many events. In addition, filter parameters are often overly generalized or contain complicated switching. We have developed a method to provide an optimized filter for any regional or teleseismically recorded event. Recorded seismic signals contain arrival energy which is localized in frequency and time. Localized temporal signals whose frequency content is different from the frequency content of the pre-arrival record are identified using rms power measurements. The method is based on the decomposition of a time series into a set of time series signals or scales. Each scale represents a time-frequency band with a constant Q. SNR is calculated for a pre-event noise window and for a window estimated to contain the arrival. Scales with high SNR are used to indicate the band pass limits for the optimized filter.The results offer a significant improvement in SNR particularly for low SNR events. Our method provides a straightforward, optimized filter which can be immediately applied to unknown regions as knowledge of the geophysical characteristics is not required. The filtered signals can be used to map the seismic frequency response of a region and may provide improvements in travel-time picking, bearing estimation

  3. On the finite-SNR diversity-multiplexing tradeoff of zero-forcing transmit scheme under secrecy constraint

    KAUST Repository

    Rezki, Zouheir

    2011-06-01

    In this paper, we address the finite Signal-to-Noise Ratio (SNR) Diversity-Multiplexing Tradeoff (DMT) of the Multiple Input Multiple Output (MIMO) wiretap channel, where a Zero-Forcing (ZF) transmit scheme, that intends to send the secret information in the orthogonal space of the eavesdropper channel, is used. First, we introduce the secret multiplexing gain at finite-SNR that generalizes the definition at high-SNR. Then, we provide upper and lower bounds on the outage probability under secrecy constraint, from which secret diversity gain estimates of ZF are derived. Through asymptotic analysis, we show that the upper bound underestimates the secret diversity gain, whereas the lower bound is tight at high-SNR, and thus its related diversity gain estimate is equal to the actual asymptotic secret diversity gain of the Multiple-Input Multiple-Output (MIMO) wiretap channel. © 2011 IEEE.

  4. Optical intensity modulation direct detection versus heterodyne detection: A high-SNR capacity comparison

    KAUST Repository

    Chaaban, Anas

    2016-09-15

    An optical wireless communications system which employs either intensity-modulation and direct-detection (IM-DD) or heterodyne detection (HD) is considered. IM-DD has lower complexity and cost than HD, but on the other hand, has lower capacity. It is therefore interesting to investigate the capacity gap between the two systems. The main focus of this paper is to investigate this gap at high SNR. Bounds on this gap are established for two cases: between IM-DD and HD, and between IM-DD and an HD-PAM which is an HD system employing pulse-amplitude modulation (PAM). While the gap between IM-DD and HD increases as the signal-to-noise ratio (SNR) increases, the gap between IM-DD and an HD-PAM is upper bounded by a constant at high SNR. © 2015 IEEE.

  5. Optical intensity modulation direct detection versus heterodyne detection: A high-SNR capacity comparison

    KAUST Repository

    Chaaban, Anas; Alouini, Mohamed-Slim

    2016-01-01

    An optical wireless communications system which employs either intensity-modulation and direct-detection (IM-DD) or heterodyne detection (HD) is considered. IM-DD has lower complexity and cost than HD, but on the other hand, has lower capacity. It is therefore interesting to investigate the capacity gap between the two systems. The main focus of this paper is to investigate this gap at high SNR. Bounds on this gap are established for two cases: between IM-DD and HD, and between IM-DD and an HD-PAM which is an HD system employing pulse-amplitude modulation (PAM). While the gap between IM-DD and HD increases as the signal-to-noise ratio (SNR) increases, the gap between IM-DD and an HD-PAM is upper bounded by a constant at high SNR. © 2015 IEEE.

  6. A Study on the Optimal Receiver Impedance for SNR Maximization in Broadband PLC

    Directory of Open Access Journals (Sweden)

    Massimo Antoniali

    2013-01-01

    Full Text Available We consider the design of the front-end receiver for broadband power line communications. We focus on the design of the input impedance that maximizes the signal-to-noise ratio (SNR at the receiver. We show that the amplitude, rather than the power, of the received signal is important for communication purposes. Furthermore, we show that the receiver impedance impacts the amplitude of the noise term. We focus on the background noise, and we propose a novel description of the noise experienced at the receiver port of a PLC network. We model the noise as the sum of four uncorrelated contributions, that is, the active, resistive, receiver, and coupled noise components. We study the optimal impedance design problem for real in-home grids that we assessed with experimental measurements. We describe the results of the measurement campaign, and we report the statistics of the optimal impedance. Hence, we study the best attainable performance when the optimal receiver impedance is deployed. We focus on the SNR and the maximum achievable rate, and we show that power matching is suboptimal with respect to the proposed impedance design approach.

  7. Effect of exposure time reduction towards sensitivity and SNR for computed radiography (CR) application in NDT

    International Nuclear Information System (INIS)

    Sapizah Rahim; Khairul Anuar Mohd Salleh; Noorhazleena Azaman; Shaharudin Sayuti; Siti Madiha Muhammad Amir; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    Signal-to-noise ratio (SNR) and sensitivity study of Computed Radiography (CR) system with reduction of exposure time is presented. The purposes of this research are to determine the behavior of SNR toward three different thicknesses (step wedge; 5, 10 and 15 mm) and the ability of CR system to recognize hole type penetrameter when the exposure time decreased up to 80 % according to the exposure chart (D7; ISOVOLT Titan E). It is shown that the SNR is decreased with decreasing of exposure time percentage but the high quality image is achieved until 80 % reduction of exposure time. (author)

  8. Changes in signal-to-noise ratios and contrast-to-noise ratios of hypervascular hepatocellular carcinomas on ferucarbotran-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Park, Yulri; Choi, Dongil; Kim, Seong Hyun; Kim, Seung Hoon; Kim, Min Ju; Lee, Jongmee; Lim, Jae Hoon; Lee, Won Jae; Lim, Hyo K.

    2006-01-01

    Purpose: To verify changes in the signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of hypervascular hepatocellular carcinomas (HCCs) on ferucarbotran-enhanced dynamic T1-weighted MR imaging. Materials and methods: Fifty-two patients with 61 hypervascular HCCs underwent ferucarbotran-enhanced dynamic MR imaging, and then hepatic resection. Hypervascular HCCs were identified when definite enhancement was noted during the arterial dominant phase of three-phase MDCT. Dynamic MR Images with T1-weighted fast multiplanar spoiled gradient-recalled echo sequence (TR200/TE4.2) were obtained before and 20 s, and 1, 3, 5, and 10 min, after bolus injection of ferucarbotran. We estimated the signal intensities of tumors and livers, and calculated the SNRs and CNRs of the tumors. Results: On ferucarbotran-enhanced dynamic MR imaging, SNR measurements showed a fluctuating pattern, namely, an increase in SNR followed by a decrease and a subsequent increase (or a decrease in SNR followed by a increase and a subsequent decrease) in 50 (82.0%) of 61 tumors, a single-peak SNR pattern (highest SNR on 20 s, 1, 3, or 5 min delayed images followed by a decrease) in seven (11.5%), and a decrease in SNR followed by an increase in four (6.6%). Maximum absolute CNRs with positive value were noted on 10 min delayed images in 41 (67.2%) tumors, and maximum absolute CNRs with negative value were observed on 20 s delayed images in 12 (19.7%) and on 1 min delayed images in eight (13.1%). Conclusion: Despite showing various SNR and CNR changes, the majority of hypervascular HCCs demonstrated a fluctuating SNR pattern on ferucarbotran-enhanced dynamic MR imaging and a highest CNR on 10 min delayed image, which differed from the classic enhancement pattern on multiphasic CT

  9. Detection of plumes at Redoubt and Etna volcanoes using the GPS SNR method

    Science.gov (United States)

    Larson, Kristine M.; Palo, Scott; Roesler, Carolyn; Mattia, Mario; Bruno, Valentina; Coltelli, Mauro; Fee, David

    2017-09-01

    Detection and characterization of volcanic eruptions is important both for public health and aircraft safety. A variety of ground sensors are used to monitor volcanic eruptions. Data from these ground sensors are subsequently incorporated into models that predict the movement of ash. Here a method to detect volcanic plumes using GPS signals is described. Rather than carrier phase data used by geodesists, the method takes advantage of attenuations in signal to noise ratio (SNR) data. Two datasets are evaluated: the 2009 Redoubt Volcano eruptions and the 2013/2015 eruptions at Mt. Etna. SNR-based eruption durations are compared with previously published seismic, infrasonic, and radar studies at Redoubt Volcano. SNR-based plume detections from Mt. Etna are compared with L-band radar and tremor observations. To place these SNR observations from Redoubt and Etna in context, a model of the propagation of GPS signals through both water/water vapor and tephra is developed. Neither water nor fine ash particles will produce the observed attenuation of GPS signals, while scattering caused by particles > 1 cm in diameter potentially could.

  10. Signal to Noise Ratio (SNR Enhancement Comparison of Impulse-, Coding- and Novel Linear-Frequency-Chirp-Based Optical Time Domain Reflectometry (OTDR for Passive Optical Network (PON Monitoring Based on Unique Combinations of Wavelength Selective Mirrors

    Directory of Open Access Journals (Sweden)

    Christopher M. Bentz

    2014-03-01

    Full Text Available We compare optical time domain reflectometry (OTDR techniques based on conventional single impulse, coding and linear frequency chirps concerning their signal to noise ratio (SNR enhancements by measurements in a passive optical network (PON with a maximum one-way attenuation of 36.6 dB. A total of six subscribers, each represented by a unique mirror pair with narrow reflection bandwidths, are installed within a distance of 14 m. The spatial resolution of the OTDR set-up is 3.0 m.

  11. Optimizing the night time with dome vents and SNR-QSO at CFHT

    Science.gov (United States)

    Devost, Daniel; Mahoney, Billy; Moutou, Claire; CFHT QSO Team, CFHT software Group

    2017-06-01

    Night time is a precious and costly commodity and it is important to get everything we can out of every second of every night of observing. In 2012 the Canada-France-Hawaii Telescope started operating 12 new vent doors installed on the dome over the course of the previous two years. The project was highly successful and seeing measurements show that venting the dome greatly enhances image quality at the focal plane. In order to capitalize on the gains brought by the new vents, the observatory started exploring a new mode of observation called SNR-QSO. This mode consist of a new implementation inside our Queued Service Observation (QSO) system. Exposure times are adjusted for each frame depending on the weather conditions in order to reach a specific depth, Signal to Noise Ratio (SNR) at a certain magnitude. The goal of this new mode is to capitalize on the exquisite seeing provided by Maunakea, complemented by the minimized dome turbulence, to use the least amount of time to reach the depth required by the science programs. Specific implementations were successfully tested on two different instruments, our wide field camera MegaCam and our high resolution spectrograph ESPaDOnS. I will present the methods used for each instrument to achieve SNR observing and the gains produced by these new observing modes in order to reach the scientific goals of accepted programs in a shorter amount of time.

  12. Measurement and analysis of vibrational behaviour of an SNR-fuel element in sodium flow

    International Nuclear Information System (INIS)

    Hess, B.F.H.; Ruppert, E.; Schmidt, H.; Vinzens, K.

    1975-01-01

    Within the framework of SNR-300 fuel element development programme a complete full size fuel element dummy has been tested thoroughly for nearly 3000 hours at 650 0 C system temperature in the AKB sodium loop at Interatom, Bensberg. Investigations of the hydraulic characteristics by measurements of specific pressure losses, flow velocities, leakage flow through the piston rings and investigations of its vibrational behaviour were part of this endurance test at elevated temperatures. The pressure drop versus flow and the leakage measurement are mentioned briefly to confirm the correctness of the test hydraulics. The vibrational behaviour of the element and the approach to analysis is the main object of this report. (Auth.)

  13. Best relay selection using SNR and interference quotient for underlay cognitive networks

    KAUST Repository

    Hussain, Syed Imtiaz

    2012-06-01

    Cognitive networks in underlay settings operate simultaneously with the primary networks satisfying stringent interference limits. This condition forces them to operate with low transmission powers and confines their area of coverage. In an effort to reach remote destinations, underlay cognitive sources make use of relaying techniques. Selecting the best relay among those who are ready to cooperate is different in underlay settings than traditional non-cognitive networks. In this paper, we present a relay selection scheme which uses the quotient of the relay link signal to noise ratio (SNR) and the interference generated from the relay to the primary user to choose the best relay. The proposed scheme optimizes this quotient in a way to maximize the relay link SNR above a certain value whereas the interference is kept below a defined threshold. We derive closed expressions for the outage probability and bit error probability of the system incorporating this scheme. Simulation results confirm the validity of the analytical results and reveal that the relay selection in cognitive environment is feasible in low SNR regions. © 2012 IEEE.

  14. A Dynamical System Exhibits High Signal-to-noise Ratio Gain by Stochastic Resonance

    Science.gov (United States)

    Makra, Peter; Gingl, Zoltan

    2003-05-01

    On the basis of mixed-signal simulations, we demonstrate that signal-to-noise ratio (SNR) gains much greater than unity can be obtained in the double-well potential through stochastic resonance (SR) with a symmetric periodic pulse train as deterministic and Gaussian white noise as random excitation. We also show that significant SNR improvement is possible in this system even for a sub-threshold sinusoid input if, instead of the commonly used narrow-band SNR, we apply an equally simple but much more realistic wide-band SNR definition. Using the latter result as an argument, we draw attention to the fact that the choice of the measure to reflect signal quality is critical with regard to the extent of signal improvement observed, and urge reconsideration of the practice prevalent in SR studies that most often the narrow-band SNR is used to characterise SR. Finally, we pose some questions concerning the possibilities of applying SNR improvement in practical set-ups.

  15. Safety design of SNR-300

    International Nuclear Information System (INIS)

    Traube, K.

    1976-01-01

    The joint German-Belgian-Dutch loop-type 300 MW(e) LMFBR prototype is being constructed at Kalkar on the lower Rhine in Germany. Among the many arguments put forward in defense of SNR-300, that of acquiring licensing exprience has proven to be of major importance to the international breeder scene. The severity of the licensing procedures and of the safety standards imposed are unique in several respects, including timing: generally growing scepticism towards nuclear power increased severity of the licensing practice; organizational features: the procedure and criteria developed for commercial light water reactors have been applied without exemptions. This relates to the commercial-type contract under which SNR-300 is being built for private utilities by a private company; and German nuclear safety standards, known worldwide to be most stringent. The following three important areas are discussed in which SNR-300 decidedly deviates from its forerunners: protection against the hypothetical core disruptive accident (HCDA), protection against external events, and provisions for in-service inspection

  16. Signal to noise ratio (SNR) and image uniformity: an estimate of performance of magnetic resonance imaging (MRI) system

    International Nuclear Information System (INIS)

    Narayan, P.; Suri, S.; Choudhary, S.R.

    2001-01-01

    In most general definition, noise in an image, is any variation that represents a deviation from truth. Noise sources in MRI can be systematic or random and statistical in nature. Data processing algorithms that smooth and enhance the edges by non-linear intensity assignments among other factors can affect the distribution of statistical noise. The SNR and image uniformity depends on the various parameters of NMR imaging system (viz. General system calibration, Gain coil tuning, AF shielding, coil loading, image processing and scan parameters like TE, TR, interslice distance, slice thickness, pixel size and matrix size). A study on SNR and image uniformity have been performed using standard head AF coil with different TR and the estimates of their variation are presented. A comparison between different techniques has also been evaluated using standard protocol of the Siemens Magnetom Vision Plus MRI system

  17. A complex symbol signal-to-noise ratio estimator and its performance

    Science.gov (United States)

    Feria, Y.

    1994-01-01

    This article presents an algorithm for estimating the signal-to-noise ratio (SNR) of signals that contain data on a downconverted suppressed carrier or the first harmonic of a square-wave subcarrier. This algorithm can be used to determine the performance of the full-spectrum combiner for the Galileo S-band (2.2- to 2.3-GHz) mission by measuring the input and output symbol SNR. A performance analysis of the algorithm shows that the estimator can estimate the complex symbol SNR using 10,000 symbols at a true symbol SNR of -5 dB with a mean of -4.9985 dB and a standard deviation of 0.2454 dB, and these analytical results are checked by simulations of 100 runs with a mean of -5.06 dB and a standard deviation of 0.2506 dB.

  18. Stratification in SNR-300 outlet plenum

    International Nuclear Information System (INIS)

    Reinders, R.

    1983-01-01

    In the inner outlet plenum of the SNR-300 under steady state conditions a large toroidal vortex is expected. The main flow passes through the gap between dipplate and shield vessel to the outer annular space. Only 3% of the flow pass the 24 emergency cooling holes, situated in the shield vessel. The sodium leaves the reactor tank through the 3 symmetrically arranged outlet nozzles. For a scram flow rates and temperatures are decreased simultaneously, so it is expected, that stratification occurs in the inner outlet plenum. A measure of stratification effects is the Archimedes Number Ar, which is the relation of buoyancy forces (negative) to kinetic energy. (The Archimedes Number is nearly identical with the Richardson Number). For values Ar>1 stratification can occur. Under the assumption of stratification the code TIRE was developed, which is only applicable for the period of time after some 50 sec after scram. This code serves for long term calculations. As the equations are very simple, it is a very fast code which gives the possibility to calculate transients for some hours real time. This code mainly has to take into account the pressure difference between inner plenum and outlet annulus caused by geodatic pressure. That force is in equilibrium with the pressure drop over the gap and holes in the shield vessel. For more detailed calculations of flow pattern and temperature distribution the code MIX and INKO 2T are applied. MIX was developed and validated at ANL, INKO 2T is a development of INTERATOM. INKO 2T is under validation. Mock up experiments were carried out with water to simulate the transient behavior of the SNR-300 outlet plenum. Calculations obtained by INKO 2T for steady state and the transient are shown for the flow pattern. Results of measurements also prove that stratification begins after about 30 sec. Measurements and detailed calculations show that it is admissible to use the code TIRE for the long term calculations. Calculations for a scram

  19. A novel method for enhancing the lateral resolution and image SNR in confocal microscopy

    Science.gov (United States)

    Chen, Youhua; Zhu, Dazhao; Fang, Yue; Kuang, Cuifang; Liu, Xu

    2017-12-01

    There is always a tradeoff between the resolution and the signal-to-noise ratio (SNR) in confocal microscopy. In particular, the pinhole size is very important for maintaining a balance between them. In this paper, we propose a method for improving the lateral resolution and image SNR in confocal microscopy without making any changes to the hardware. By using the fluorescence emission difference (FED) approach, we divide the images acquired by different pinhole sizes into one image acquired by the central pinhole and several images acquired by ring-shaped pinholes. Then, they are added together with the deconvolution method. Simulation and experimental results for fluorescent particles and cells show that our method can achieve a far better resolution than a large pinhole and a higher SNR than a small pinhole. Moreover, our method can improve the performance of classic confocal laser scanning microscopy (CLSM) to a certain extent, especially CLSM with a continuously variable pinhole.

  20. [The radial velocity measurement accuracy of different spectral type low resolution stellar spectra at different signal-to-noise ratio].

    Science.gov (United States)

    Wang, Feng-Fei; Luo, A-Li; Zhao, Yong-Heng

    2014-02-01

    The radial velocity of the star is very important for the study of the dynamics structure and chemistry evolution of the Milky Way, is also an useful tool for looking for variable or special objects. In the present work, we focus on calculating the radial velocity of different spectral types of low-resolution stellar spectra by adopting a template matching method, so as to provide effective and reliable reference to the different aspects of scientific research We choose high signal-to-noise ratio (SNR) spectra of different spectral type stellar from the Sloan Digital Sky Survey (SDSS), and add different noise to simulate the stellar spectra with different SNR. Then we obtain theradial velocity measurement accuracy of different spectral type stellar spectra at different SNR by employing a template matching method. Meanwhile, the radial velocity measurement accuracy of white dwarf stars is analyzed as well. We concluded that the accuracy of radial velocity measurements of early-type stars is much higher than late-type ones. For example, the 1-sigma standard error of radial velocity measurements of A-type stars is 5-8 times as large as K-type and M-type stars. We discuss the reason and suggest that the very narrow lines of late-type stars ensure the accuracy of measurement of radial velocities, while the early-type stars with very wide Balmer lines, such as A-type stars, become sensitive to noise and obtain low accuracy of radial velocities. For the spectra of white dwarfs stars, the standard error of radial velocity measurement could be over 50 km x s(-1) because of their extremely wide Balmer lines. The above conclusion will provide a good reference for stellar scientific study.

  1. Description of the global fuel element failure detection for SNR 300

    International Nuclear Information System (INIS)

    Dauk, J.

    1985-07-01

    For the detection of fission products in the cover gas of SNR 300 a high-resolution gamma-spectrometer with connected mini-computer is applied. The mechanical structure of the two Ge-detectors, which are positioned at two redundant gas lines, the analogous electronic and the structure of the computer with its periphery are described in this report. The concept of the software is presented, which had been developed especially for SNR 300. The start-up of the system and the calibration of the auxiliary measuring points and of the Ge-detectors are described [de

  2. Joint volumetric extraction and enhancement of vasculature from low-SNR 3-D fluorescence microscopy images.

    Science.gov (United States)

    Almasi, Sepideh; Ben-Zvi, Ayal; Lacoste, Baptiste; Gu, Chenghua; Miller, Eric L; Xu, Xiaoyin

    2017-03-01

    To simultaneously overcome the challenges imposed by the nature of optical imaging characterized by a range of artifacts including space-varying signal to noise ratio (SNR), scattered light, and non-uniform illumination, we developed a novel method that segments the 3-D vasculature directly from original fluorescence microscopy images eliminating the need for employing pre- and post-processing steps such as noise removal and segmentation refinement as used with the majority of segmentation techniques. Our method comprises two initialization and constrained recovery and enhancement stages. The initialization approach is fully automated using features derived from bi-scale statistical measures and produces seed points robust to non-uniform illumination, low SNR, and local structural variations. This algorithm achieves the goal of segmentation via design of an iterative approach that extracts the structure through voting of feature vectors formed by distance, local intensity gradient, and median measures. Qualitative and quantitative analysis of the experimental results obtained from synthetic and real data prove the effcacy of this method in comparison to the state-of-the-art enhancing-segmenting methods. The algorithmic simplicity, freedom from having a priori probabilistic information about the noise, and structural definition gives this algorithm a wide potential range of applications where i.e. structural complexity significantly complicates the segmentation problem.

  3. Acoustics of fish shelters: background noise and signal-to-noise ratio.

    Science.gov (United States)

    Lugli, Marco

    2014-12-01

    Fish shelters (flat stones, shells, artificial covers, etc., with a hollow beneath) increase the sound pressure levels of low frequency sounds (noise ratio (SNR) in the nest. Background noise amplification by the shelter was examined under both laboratory (stones and shells) and field (stones) conditions, and the SNR of tones inside the nest cavity was measured by performing acoustic tests on stones in the stream. Stone and shell shelters amplify the background noise pressure levels inside the cavity with comparable gains and at similar frequencies of an active sound source. Inside the cavity of stream stones, the mean SNR of tones increased significantly below 125 Hz and peaked at 65 Hz (+10 dB). Implications for fish acoustic communication inside nest enclosures are discussed.

  4. A study on evaluating validity of SNR calculation using a conventional two region method in MR images applied a multichannel coil and parallel imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kwan Woo; Son, Soon Yong [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Min, Jung Whan [Dept. of Radiological Technology, Shingu University, Sungnam (Korea, Republic of); Kwon, Kyung Tae [Dept. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Yoo, Beong Gyu; Lee, Jong Seok [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2015-12-15

    The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

  5. Methods and findings of the SNR study

    International Nuclear Information System (INIS)

    Koeberlein, K.; Schaefer, H.; Spindler, H.

    1983-01-01

    A featfinding committee of the German Federal Parliament in July 1980 recommended to perform a ''risk-oriented study'' of the SNR-300, the German 300 MW fast breeder prototype reactor being under construction in Kalkar. The main aim of this study was to allow a comparative safety evaluation between the SNR-300 and a modern PWR, thus to prepare a basis for a political decision on the SNR-300. Methods and main results of the study are presented in this paper. In the first step of the risk analysis six groups of accidents have been identified which may initiate core destruction. These groups comprise all conceivable courses, potentially leading to core destruction. By reliability analyses, expected frequency of each group has been calculated. In the accident analysis potential failure modes of the reactor tank have been investigated. Core destruction may be accompanied by the release of significant amounts of mechanical energy. The primary coolant system of SNR-300 is designed to withstand mechanical energy releases up to 370 MJ. Design features make it possible to cool the molten core inside the reactor tank. (orig./RW) [de

  6. Secret-key agreement over spatially correlated multiple-antenna channels in the low-SNR regime

    KAUST Repository

    Zorgui, Marwen; Rezki, Zouheir; Alomair, Basel; Jorswieck, Eduard A.; Alouini, Mohamed-Slim

    2015-01-01

    We consider secret-key agreement with public discussion over Rayleigh fast-fading channels with transmit, receive and eavesdropper correlation. The legitimate receiver along with the eavesdropper are assumed to have perfect channel knowledge while the transmitter has only knowledge of the correlation matrices. We analyze the secret-key capacity in the low signal-to-noise ratio (SNR) regime. We derive closed-form expressions for the first and the second derivatives of the secret-key capacity with respect to SNR at SNR= 0, for arbitrary correlation matrices and number of transmit, receive and eavesdropper antennas. Moreover, we identify optimal transmission strategies achieving these derivatives. For instance, we prove that achieving the first and the second derivatives requires a uniform power distribution between the eigenvectors spanning the maximal-eigenvalue eigenspace of the transmit correlation matrix. We also compare the optimal transmission scheme to a simple uniform power allocation. Finally, we express the minimum energy required for sharing a secret-key bit as well as the wideband slope in terms of the system parameters.

  7. Secret-key agreement over spatially correlated multiple-antenna channels in the low-SNR regime

    KAUST Repository

    Zorgui, Marwen

    2015-09-28

    We consider secret-key agreement with public discussion over Rayleigh fast-fading channels with transmit, receive and eavesdropper correlation. The legitimate receiver along with the eavesdropper are assumed to have perfect channel knowledge while the transmitter has only knowledge of the correlation matrices. We analyze the secret-key capacity in the low signal-to-noise ratio (SNR) regime. We derive closed-form expressions for the first and the second derivatives of the secret-key capacity with respect to SNR at SNR= 0, for arbitrary correlation matrices and number of transmit, receive and eavesdropper antennas. Moreover, we identify optimal transmission strategies achieving these derivatives. For instance, we prove that achieving the first and the second derivatives requires a uniform power distribution between the eigenvectors spanning the maximal-eigenvalue eigenspace of the transmit correlation matrix. We also compare the optimal transmission scheme to a simple uniform power allocation. Finally, we express the minimum energy required for sharing a secret-key bit as well as the wideband slope in terms of the system parameters.

  8. Effects of the physiological parameters on the signal-to-noise ratio of single myoelectric channel

    Directory of Open Access Journals (Sweden)

    Zhang YT

    2007-08-01

    Full Text Available Abstract Background An important measure of the performance of a myoelectric (ME control system for powered artificial limbs is the signal-to-noise ratio (SNR at the output of ME channel. However, few studies illustrated the neuron-muscular interactive effects on the SNR at ME control channel output. In order to obtain a comprehensive understanding on the relationship between the physiology of individual motor unit and the ME control performance, this study investigates the effects of physiological factors on the SNR of single ME channel by an analytical and simulation approach, where the SNR is defined as the ratio of the mean squared value estimation at the channel output and the variance of the estimation. Methods Mathematical models are formulated based on three fundamental elements: a motoneuron firing mechanism, motor unit action potential (MUAP module, and signal processor. Myoelectric signals of a motor unit are synthesized with different physiological parameters, and the corresponding SNR of single ME channel is numerically calculated. Effects of physiological multi factors on the SNR are investigated, including properties of the motoneuron, MUAP waveform, recruitment order, and firing pattern, etc. Results The results of the mathematical model, supported by simulation, indicate that the SNR of a single ME channel is associated with the voluntary contraction level. We showed that a model-based approach can provide insight into the key factors and bioprocess in ME control. The results of this modelling work can be potentially used in the improvement of ME control performance and for the training of amputees with powered prostheses. Conclusion The SNR of single ME channel is a force, neuronal and muscular property dependent parameter. The theoretical model provides possible guidance to enhance the SNR of ME channel by controlling physiological variables or conscious contraction level.

  9. Multiengine Speech Processing Using SNR Estimator in Variable Noisy Environments

    Directory of Open Access Journals (Sweden)

    Ahmad R. Abu-El-Quran

    2012-01-01

    Full Text Available We introduce a multiengine speech processing system that can detect the location and the type of audio signal in variable noisy environments. This system detects the location of the audio source using a microphone array; the system examines the audio first, determines if it is speech/nonspeech, then estimates the value of the signal to noise (SNR using a Discrete-Valued SNR Estimator. Using this SNR value, instead of trying to adapt the speech signal to the speech processing system, we adapt the speech processing system to the surrounding environment of the captured speech signal. In this paper, we introduced the Discrete-Valued SNR Estimator and a multiengine classifier, using Multiengine Selection or Multiengine Weighted Fusion. Also we use the SI as example of the speech processing. The Discrete-Valued SNR Estimator achieves an accuracy of 98.4% in characterizing the environment's SNR. Compared to a conventional single engine SI system, the improvement in accuracy was as high as 9.0% and 10.0% for the Multiengine Selection and Multiengine Weighted Fusion, respectively.

  10. Background- and simulated leak-noise measurements on ASB-loop, KNK II- and SNR 300-steam generators

    International Nuclear Information System (INIS)

    Voss, J.; Arnaoutis, N.; Foerster, K.; Moellerfeld, H.

    1990-01-01

    During several leak propagation experiments in the ASB sodium loop noise measurements were performed showing the acoustic behaviour of evoluting leaks in a tube bundle section under sodium. Effects like self evolution, secondary leaks and tube ruptures by overheating occurred during these tests and were reflected in the course of acoustic signals. In one of the KNK II steam generators simulated leak noise was detected against background noise throughout the operating power range. Experimental arrangements and results are described. In SNR 300 all of the SGUs are equipped with waveguides and some with accelerometers for background noise measurements. First measurement under isothermal conditions were performed in the past. A gas injection device for acoustic leak simulation is under construction. The design of the experimental acoustic system and first results are presented. (author). 1 ref., 21 figs, 2 tabs

  11. Signal-noise ratio of MR spectroscopy in the central gland of prostate

    International Nuclear Information System (INIS)

    Tong Yanjun; Wang Xiaoying; Li Feiyu; Jiang Xuexiang

    2007-01-01

    Objective: To analyze the signal to noise ratio (SNR) of the MRS of the prostate central gland, and study its relationship with the pathology of the lesions. Methods: Eighteen patients who underwent transurethral resection of prostate (TURP) for benign prostate hyperplasia (BPH) were enrolled in this study. They were divided into three groups according to the pathological findings: 7 cases of glandular-BPH (GBPH), 7 cases of stromal-BPH (SBPH) and 5 cases of incidentally detected prostate carcinoma (IDPC). The voxels in the central glands with SNR ≥5 and SNR < 5 were counted, and the relationship between the percentage of voxel with SNR < 5 and pathology was analyzed. Results: In the 18 cases, the total number of voxels measured in the regions of interest was 3632, and the voxels with SNR≥5 and SNR < 5 were 1579 (the percentage is 43%) and 1873, respectively. The percentage of voxels with SNR < 5 in SBPH group (67.6 ± 21.8)% was statistically higher than that in GBPH (37.1±14.5)% and IDPC (39.9±18.8)%. The difference between the group of GBPH and IDPC was not statistically significant. Conclusion: More than half of the voxels in the central gland could not be reliably analyzed in the prostate MRS examination because of its low SNR, especially in the case of SBPH. (authors)

  12. Modeling signal-to-noise ratio of otoacoustic emissions in workers exposed to different industrial noise levels

    Directory of Open Access Journals (Sweden)

    Parvin Nassiri

    2016-01-01

    Full Text Available Introduction: Noise is considered as the most common cause of harmful physical effects in the workplace. A sound that is generated from within the inner ear is known as an otoacoustic emission (OAE. Distortion-product otoacoustic emissions (DPOAEs assess evoked emission and hearing capacity. The aim of this study was to assess the signal-to-noise ratio in different frequencies and at different times of the shift work in workers exposed to various levels of noise. It was also aimed to provide a statistical model for signal-to-noise ratio (SNR of OAEs in different frequencies based on the two variables of sound pressure level (SPL and exposure time. Materials and Methods: This case–control study was conducted on 45 workers during autumn 2014. The workers were divided into three groups based on the level of noise exposure. The SNR was measured in frequencies of 1000, 2000, 3000, 4000, and 6000 Hz in both ears, and in three different time intervals during the shift work. According to the inclusion criterion, SNR of 6 dB or greater was included in the study. The analysis was performed using repeated measurements of analysis of variance, spearman correlation coefficient, and paired samples t-test. Results: The results showed that there was no statistically significant difference between the three exposed groups in terms of the mean values of SNR (P > 0.05. Only in signal pressure levels of 88 dBA with an interval time of 10:30–11:00 AM, there was a statistically significant difference between the right and left ears with the mean SNR values of 3000 frequency (P = 0.038. The SPL had a significant effect on the SNR in both the right and left ears (P = 0.023, P = 0.041. The effect of the duration of measurement on the SNR was statistically significant in both the right and left ears (P = 0.027, P < 0.001. Conclusion: The findings of this study demonstrated that after noise exposure during the shift, SNR of OAEs reduced from the

  13. Evaluation and comparison of signal to noise ratio according to histogram equalization of heart shadow on chest image

    International Nuclear Information System (INIS)

    Kim, Ki Won; Lee, Eul Kyu; Jeong, Hoi Woun; Kang, Byung Sam; Kim, Hyun Soo; Min, Jung Whan; Son, Jin Hyun

    2017-01-01

    The purpose of this study was to measure signal to noise ratio (SNR) according to change of equalization from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 87 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using Image. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p < 0.05). In SNR results, with the quality of distributions in the order of original chest image, original chest image heart shadow and equalization chest image, equalization chest image heart shadow(p < 0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the histogram equalization chest image

  14. Evaluation and comparison of signal to noise ratio according to histogram equalization of heart shadow on chest image

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Lee, Eul Kyu [Inje Paik University Hospital at Jeo-dong, Seoul (Korea, Republic of); Jeong, Hoi Woun [The Baekseok Culture University, Cheonan (Korea, Republic of); Kang, Byung Sam; Kim, Hyun Soo; Min, Jung Whan; Son, Jin Hyun [The Shingu University, Seongnam (Korea, Republic of)

    2017-06-15

    The purpose of this study was to measure signal to noise ratio (SNR) according to change of equalization from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 87 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using Image. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p < 0.05). In SNR results, with the quality of distributions in the order of original chest image, original chest image heart shadow and equalization chest image, equalization chest image heart shadow(p < 0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the histogram equalization chest image.

  15. Summary of results for the SNEAK-9 series of critical experiments and conclusions for the accuracy of predicted physics parameters of the SNR-300

    International Nuclear Information System (INIS)

    Helm, F.

    1978-08-01

    In a series of critical assembles in SNEAK physics parameters of interest for the prototype fast reactor SNR-300 were investigated and compared to the results of calculations. Since a complete mock-up of the SNR-300 was not possible with the material supply available the measurements were performed in three different assemblies, each being adapted to the investigation of a particular set of problems. Work was concentrated on the following quantities: criticality, breeding ratio, Na-void effect, control rod worths and power distribution. The calculation were performed using the diffusion and transport methods available at KFK and as a data basis the KFKINER cross section set. Detailed descriptions of the assemblies, the majority of the results and extensive discussions of the experimental and calculational methods used can be found in separate KFK reports about each assembly which were already published. This report contains a summary of the results for each quantity investigated including a basic account of the methods used, and an evaluation of the significance of these data for the prediction of parameters of the SNR-300. (orig.) 891 RW [de

  16. Radio-continuum study of the supernova remnants in the large Magellanic Cloud: An SNR with a highly polarized breakout region: SNR J0455-6838

    Directory of Open Access Journals (Sweden)

    Crawford E.J.

    2008-01-01

    Full Text Available We present the results of new moderate resolution ATCA observations of SNR J0455-6838. We found that this SNR exhibits a mostly typical appearance with rather steep and curved α=-0.81±0.18 and D=43×31±1 pc. Regions of high polarization were detected, including unusually strong (~70% region corresponding to the northern breakout. Such a strong polarization in breakout regions has not been observed in any other SNR.

  17. Use of zero power plutonium reactor measurements as a support of criticality prediction for the SNR-300

    International Nuclear Information System (INIS)

    Pilate, S.; de Wouters, R.; Wehmann, U.; Helm, F.; Scholtyssek, W.

    1978-01-01

    Evaluations of criticality measurements performed in various SNEAK and Zero Power Plutonium Reactor (ZPPR) cores are compared. The best available methods of calculations (including transport theory) are used. The ZPPR results support well the trend indicated by the SNEAK evaluations for clean cores and for cores with followers; for cores with absorbers partially inserted, the agreement is only rough. Evaluations of control rod worth measurements are therefore also compared, using the routine method of calculation for SNR-300 (diffusion theory). The control rod worths are largely underestimated in SNEAK (C/E = 0.89), but only slightly underestimated in the ZPPR (C/E = 0.97). The difference in the nature of core fuel (uranium in SNEAK, plutonium in the ZPPR) could be at the origin of this discrepancy

  18. Diffusion-weighted MRI of the prostate at 3.0 T: Comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI—The impact of SNR on ADC measurement

    International Nuclear Information System (INIS)

    Mazaheri, Yousef; Vargas, H. Alberto; Nyman, Gregory; Shukla-Dave, Amita; Akin, Oguz; Hricak, Hedvig

    2013-01-01

    Purpose: To compare ADC values measured from diffusion-weighted MR (DW-MR) images of the prostate obtained with both endorectal and phased-array coils (ERC + PAC) to those from DW-MRI images obtained with an eight-channel torso phased-array coil (PAC) at 3.0 T. Methods: The institutional review board issued a waiver of informed consent for this HIPAA-compliant study. Twenty-five patients with biopsy-proven prostate cancer underwent standard 3-T MRI using 2 different coil arrangements (ERC + PAC and PAC only) in the same session. DW-MRI at five b-values (0, 600, 1000, 1200, and 1500 s/mm 2 ) were acquired using both coil arrangements. On b = 0 images, signal-to-noise ratios (SNRs) were measured as the ratio of the mean signal from PZ and TZ ROIs to the standard deviation from the mean signal in an artifact-free ROI in the rectum. Matching regions-of-interest (ROIs) were identified in the peripheral zone and transition zone on ERC-MRI and PAC-MRI. For each ROI, mean ADC values for all zero and non-zero b-value combinations were computed. Results: Mean SNR with ERC-MRI at PZ (66.33 ± 27.07) and TZ (32.69 ± 12.52) was 9.27 and 5.52 times higher than with PAC-MRI ((7.32 ± 2.30) and (6.13 ± 1.56), respectively) (P < 0.0001 for both). ADCs from DW-MR images obtained with all b-values in the PZ and TZ were significantly lower with PAC-MRI than with ERC-MRI (P < 0.001 for all). Conclusion: Lower SNR of DW-MR images of the prostate obtained with a PAC can significantly decrease ADC values at higher b-values compared to similar measurements obtained using the ERC. To address these requirements, clinical MR systems should have image processing capabilities which incorporate the noise distribution

  19. Signal-to-noise ratio, contrast-to-noise ratio and their trade-offs with resolution in axial-shear strain elastography

    International Nuclear Information System (INIS)

    Thitaikumar, Arun; Krouskop, Thomas A; Ophir, Jonathan

    2007-01-01

    In axial-shear strain elastography, the local axial-shear strain resulting from the application of quasi-static axial compression to an inhomogeneous material is imaged. In this paper, we investigated the image quality of the axial-shear strain estimates in terms of the signal-to-noise ratio (SNR asse ) and contrast-to-noise ratio (CNR asse ) using simulations and experiments. Specifically, we investigated the influence of the system parameters (beamwidth, transducer element pitch and bandwidth), signal processing parameters (correlation window length and axial window shift) and mechanical parameters (Young's modulus contrast, applied axial strain) on the SNR asse and CNR asse . The results of the study show that the CNR asse (SNR asse ) is maximum for axial-shear strain values in the range of 0.005-0.03. For the inclusion/background modulus contrast range considered in this study ( asse (SNR asse ) is maximum for applied axial compressive strain values in the range of 0.005%-0.03%. This suggests that the RF data acquired during axial elastography can be used to obtain axial-shear strain elastograms, since this range is typically used in axial elastography as well. The CNR asse (SNR asse ) remains almost constant with an increase in the beamwidth while it increases as the pitch increases. As expected, the axial shift had only a weak influence on the CNR asse (SNR asse ) of the axial-shear strain estimates. We observed that the differential estimates of the axial-shear strain involve a trade-off between the CNR asse (SNR asse ) and the spatial resolution only with respect to pitch and not with respect to signal processing parameters. Simulation studies were performed to confirm such an observation. The results demonstrate a trade-off between CNR asse and the resolution with respect to pitch

  20. MIMO channel capacity with full CSI at Low SNR

    KAUST Repository

    Tall, Abdoulaye

    2012-10-01

    In this paper, we characterize the ergodic capacity of Multiple Input Multiple Output (MIMO) Rayleigh fading channels with full channel state information (CSI) at both the transmitter (CSI-T) and the receiver (CSI-R) at asymptotically low signal-to-noise ratio (SNR). A simple analytical expression of the capacity is derived for any number of transmit and receive antennas. This characterization clearly shows the substantial gain in terms of capacity over the no CSI-T case and gives a good insight on the effect of the number of antennas used. In addition, an On-Off transmission scheme is proposed and is shown to be asymptotically capacity-achieving. © 2012 IEEE.

  1. Symbol signal-to-noise ratio loss in square-wave subcarrier downconversion

    Science.gov (United States)

    Feria, Y.; Statman, J.

    1993-01-01

    This article presents the simulated results of the signal-to-noise ratio (SNR) loss in the process of a square-wave subcarrier down conversion. In a previous article, the SNR degradation was evaluated at the output of the down converter based on the signal and noise power change. Unlike in the previous article, the SNR loss is defined here as the difference between the actual and theoretical symbol SNR's for the same symbol-error rate at the output of the symbol matched filter. The results show that an average SNR loss of 0.3 dB can be achieved with tenth-order infinite impulse response (IIR) filters. This loss is a 0.2-dB increase over the SNR degradation in the previous analysis where neither the signal distortion nor the symbol detector was considered.

  2. Evaluation of special safety features of the SNR-300 in view of the Chernobyl accident

    International Nuclear Information System (INIS)

    Vossebrecker, H.

    1987-03-01

    A comparison of those characteristics, which decisively influenced the accident in the RMBK-1000 reactor, with the safety features of SNR-300 has been performed. The conclusions of this comparison are presented in the present report. The SNR-300 is characterized by a stable reactivity behaviour and good controllability, whereas RBMK-1000 has an instable behaviour and complex spatial dependencies in the core. Among other points, design deficiencies in the protection and emergency shutdown systems were responsible for the Chernobyl accident. The protection and scram systems of the SNR-300 are unquestionably superior to those of the RBMK-1000 with regard to redundancy, diversity, degree of automation, separation of operational and safety-relevant tasks, protection against inadmissible interventions, effectiveness and safety reserves. Therefore, excursion accidents can be classified as hypothetical for SNR-300. Due to elementary physical properties, possible energy releases during hypothetical excursions are substantially lower for SNR-300 and would be controlled by the design of the primary system and containment systems. No damage limiting measures are provided in the RBMK-100 for excursion accidents. Finally, exothermal processes augmented the consequences of the accident in the RBMK-1000 and the long-lasting graphite fire intensified the release of radioactivity. In the SNR-300, however, inertisation of the containment, the steel plate lining and the floor troughs ensure that activity enclosure inside the containment after leakage or hypothetical excursion accident is not endangered by exothermal reactions. Further safety aspects are presented in the report, which can be linked with the accident in Chernobyl. In summary, it is obvious that the disadvantageous physical and technical features of the RBMK-1000 do either not exist in the SNR-300 or are covered by the safety design

  3. Cavitation problems in mixing devices of SNR-300 fuel elements

    International Nuclear Information System (INIS)

    Benemann, A.

    1976-01-01

    Because of a complex flow path within the mixing device developed for the fuel elements of the SNR-300, in order to determine the minimum allowable interval to the beginning of cavitation, experimental tests with the original geometry are necessary. These conclusions show that for cavitation values CV>=1,3 - in the model and prototype - no cavitation zones can form. For reactor conditions a maximum velocity of Vsub(max)=4,7m/sec is therefore allowable in the free annular space of the compensator unit which corresponds to a massflow of M=22,5kg/sec. A cavitation value of CV=1,5 can be figured for the 120% load factor (M=20,4kg/sec,T=560 0 C). The mixing device developed is free of cavitation under the present conditions in the SNR-300. The condition of the fully developed cavitation is evidenced by a white noise with frequencies of at least 2.000 - 300.000cps and a signal/noise ratio S/R>40dB. The pressure amplitudes dependent on frequency are propagated in the streaming fluid and are severely damped by the locally existing two-phase flow. The unstable range at the beginning of cavitation is characterized by frequencies of about f=15.000cps

  4. Present status and further objectives of SNR fuel element development

    International Nuclear Information System (INIS)

    Karsten, G.

    Within the scope of the fuel element development program for the fast breeder reactor SNR 300, 500 fuel pins have been irradiated since 1964, 250 of them in fast flux. Results indicate that the maximum nominal target burnup of 90.000 MWd/t of the SNR 300 Mk Ia possibly can be reached. The main problems, which arise from clad swelling and internal corrosion, can be met by special pretreatments of the austenitic stainless steel 1.4970 and a fuel stoichiometry of 1.97. Beyond this target burnup either material property improvements have to be made or burnup reductions have to be accepted. The remaining questions can be answered by the use of the SNR 300 as a test reactor. A further target is the development of a carbide fuel element, which should be very effective in a high power breeder reactor because of its low fissile inventory and high breeding gain. This development program will also be finalized in the SNR 300. (U.S.)

  5. Signal noise ratio analysis and on-orbit performance estimation of a solar occultation Fourier transform spectrometer

    Science.gov (United States)

    Li, Bicen; Xu, Pengmei; Hou, Lizhou; Wang, Caiqin

    2017-10-01

    Taking the advantages of high spectral resolution, high sensitivity and wide spectral coverage, space borne Fourier transform infrared spectrometer (FTS) plays more and more important role in atmospheric composition sounding. The combination of solar occultation and FTS technique improves the sensitivity of instrument. To achieve both high spectral resolution and high signal to noise ratio (SNR), reasonable allocation and optimization for instrument parameters are the foundation and difficulty. The solar occultation FTS (SOFTS) is a high spectral resolution (0.03 cm-1) FTS operating from 2.4 to 13.3 μm (750-4100cm-1), which will determine the altitude profile information of typical 10-100km for temperature, pressure, and the volume mixing ratios for several dozens of atmospheric compositions. As key performance of SOFTS, SNR is crucially important to high accuracy retrieval of atmospheric composition, which is required to be no less than 100:1 at the radiance of 5800K blackbody. Based on the study of various parameters and its interacting principle, according to interference theory and operation principle of time modulated FTS, a simulation model of FTS SNR has been built, which considers satellite orbit, spectral radiometric features of sun and atmospheric composition, optical system, interferometer and its control system, measurement duration, detector sensitivity, noise of detector and electronic system and so on. According to the testing results of SNR at the illuminating of 1000 blackbody, the on-orbit SNR performance of SOFTS is estimated, which can meet the mission requirement.

  6. Influence of range-gated intensifiers on underwater imaging system SNR

    Science.gov (United States)

    Wang, Xia; Hu, Ling; Zhi, Qiang; Chen, Zhen-yue; Jin, Wei-qi

    2013-08-01

    Range-gated technology has been a hot research field in recent years due to its high effective back scattering eliminating. As a result, it can enhance the contrast between a target and its background and extent the working distance of the imaging system. The underwater imaging system is required to have the ability to image in low light level conditions, as well as the ability to eliminate the back scattering effect, which means that the receiver has to be high-speed external trigger function, high resolution, high sensitivity, low noise, higher gain dynamic range. When it comes to an intensifier, the noise characteristics directly restrict the observation effect and range of the imaging system. The background noise may decrease the image contrast and sharpness, even covering the signal making it impossible to recognize the target. So it is quite important to investigate the noise characteristics of intensifiers. SNR is an important parameter reflecting the noise features of a system. Through the use of underwater laser range-gated imaging prediction model, and according to the linear SNR system theory, the gated imaging noise performance of the present market adopted super second generation and generation Ⅲ intensifiers were theoretically analyzed. Based on the active laser underwater range-gated imaging model, the effect to the system by gated intensifiers and the relationship between the system SNR and MTF were studied. Through theoretical and simulation analysis to the image intensifier background noise and SNR, the different influence on system SNR by super second generation and generation Ⅲ ICCD was obtained. Range-gated system SNR formula was put forward, and compared the different effect influence on the system by using two kind of ICCDs was compared. According to the matlab simulation, a detailed analysis was carried out theoretically. All the work in this paper lays a theoretical foundation to further eliminating back scattering effect, improving

  7. The southern molecular environment of SNR G18.8+0.3

    OpenAIRE

    Paron, S.; Peña, M. Celis; Ortega, M. E.; Petriela, A.; Dubner, G.; Giacina, E.; Rubio, M.

    2015-01-01

    In a previous paper we have investigated the molecular environment towardsthe eastern border of the SNR G18.8+0.3. Continuing with the study of thesurroundings of this SNR, in this work we focus on its southern border, whichin the radio continuum emission shows a very peculiar morphology with acorrugated corner and a very flattened southern flank. We observed two regionstowards the south of SNR G18.8+0.3 using the Atacama Submillimeter TelescopeExperiment (ASTE) in the 12CO J=3-2. One of thes...

  8. Risk-oriented analysis on the German prototype fast breeder reactor SNR-300

    International Nuclear Information System (INIS)

    Bayer, A.; Koeberlein, K.; Gesellschaft fuer Reaktorsicherheit, Garching, Germany)

    1984-01-01

    On request of a fact-finding committee of the German Federal Parliament, a risk-oriented analysis on the SNR-300, the German prototype fast breeder reactor, has been performed to allow a pragmatic safety comparison of the SNR-300 and a modern light-water reactor. Results of the technical plant analysis have been summarized in seven release categories. Accident consequences have been calculated for the actual site at Kalkar/Rhine. The results indicate that for the SNR-300 both the frequency of major accidents and the consequences of accidents are smaller than for the pressurized-water reactor analyzed in the German Risk Study. This article summarizes the methods and main results of the analysis of the SNR-300

  9. Carrier tracking by smoothing filter improves symbol SNR

    Science.gov (United States)

    Pomalaza-Raez, Carlos A.; Hurd, William J.

    1986-01-01

    The potential benefit of using a smoothing filter to estimate carrier phase over use of phase locked loops (PLL) is determined. Numerical results are presented for the performance of three possible configurations of the deep space network advanced receiver. These are residual carrier PLL, sideband aided residual carrier PLL, and finally sideband aiding with a Kalman smoother. The average symbol signal to noise ratio (SNR) after losses due to carrier phase estimation error is computed for different total power SNRs, symbol rates and symbol SNRs. It is found that smoothing is most beneficial for low symbol SNRs and low symbol rates. Smoothing gains up to 0.4 dB over a sideband aided residual carrier PLL, and the combined benefit of smoothing and sideband aiding relative to a residual carrier loop is often in excess of 1 dB.

  10. Synchronization of OFDM at low SNR over an AWGN channel

    NARCIS (Netherlands)

    Kokkeler, Andre B.J.; Smit, Gerardus Johannes Maria; Dimitrova, D.C.; Blom, K.C.H.; Meratnia, Nirvana

    2011-01-01

    This paper is based on Extended Symbol OFDM (ES-OFDM) where symbols are extended in time. This way ES-OFDM can operate at low SNR. Each doubling of the symbol length improves the SNR performance by 3 dB in case of a coherent receiver. One of the basic questions is how to synchronize to signals far

  11. Safety and risk assessments for the SNR 300

    International Nuclear Information System (INIS)

    Maschek, W.; Froehlich, R.; Jacobs, H.; Schikorr, M.; Heusener, G.; Caldarola, L.; Royl, P.; Struwe, D.

    1983-01-01

    Under the official inquiry ''Future Nuclear Energy Policies'', KfK have carried out a number of studies concerning the hazards arising from core-destructive accidents at the SNR-300 reactor. Among these, there was the so-called ''Upper Limit Study'' providing a critical evaluation of literature on all research done on core-destructive accidents (Bethe-Tait excursion) with a high mechanic energy release potential; the other one was the so-called ''SAI Study'' (a cooperation of KfK, Science Applications, Inc. (SAI) and Interatom (IA)) which investigated the hazards of an uncontrolled coolant flow rate disturbance occurring in the SNR-300 reactor. KfK also took part in the analysis of hazards comparing the SNR-300 reactor with an LWR-type reactor like the one at Biblis B, ordered by the Federal Ministry of Research and Technology (BMFT). These studies have already been dealt with KfK-Nachrichten, 14th annual set issue 4/1982. The article on hand summarizes and evaluates once more the most important results. (orig./RW) [de

  12. Multifrequency radio observations of a SNR in the LMC: The case of SNR J0527-6549 (DEM l204

    Directory of Open Access Journals (Sweden)

    Bozzetto L.M.

    2010-01-01

    Full Text Available We present a detailed study and results of new Australia Telescope Compact Array (ATCA observations of supernova remnant SNR J0527-6549. This Large Magellanic Cloud (LMC object follows a typical supernova remnant (SNR horseshoe morphology with a diameter of D=(66×58±1 pc which is among the largest SNRs in the LMC. Its relatively large size indicates older age while a steeper than expected radio spectral index of α=-0.92±0.11 is more typical of younger and energetic SNRs. Also, we report detections of regions with a high order of polarization at a peak value of ~54%±17% at 6 cm.

  13. PSR B 1706-44 and the SNR G 343.1-2.3 as the remnants of a cavity supernova explosion

    Science.gov (United States)

    Bock, D. C.-J.; Gvaramadze, V. V.

    2002-11-01

    The possible association of the supernova remnant (SNR) G 343.1-2.3 with the pulsar PSR B 1706-44 (superposed on the arclike ``shell" of the SNR) has been questioned by some authors on the basis of an inconsistency between the implied and measured (scintillation) transverse velocities of the pulsar, the absence of any apparent interaction between the pulsar and the SNR's ``shell'', and some other indirect arguments. We suggest, however, that this association could be real if both objects are the remnants of a supernova (SN) which exploded within a mushroom-like cavity (created by the SN progenitor wind breaking out of the parent molecular cloud). This suggestion implies that the actual shape of the SNR's shell is similar to that of the well-known SNR VRO 42.05.01 and that the observed bright arc corresponds to the ``half'' of the SNR located inside the cloud. We report the discovery in archival radio data of an extended ragged radio arc to the southeast of the bright arc which we interpret as the ``half'' of the SN blast wave expanding in the intercloud medium.

  14. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas

    2018-02-19

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  15. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2018-01-01

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  16. Review on Dutch-German steam generator safety activities in the field of SNR-development

    International Nuclear Information System (INIS)

    Dumm, K.; Westenbrugge, J.K. van

    1984-01-01

    This paper reviews the results of the experimental and theoretical safety related work for SNR steam generators in brief. A review of the operating experience with SNR-300 sodium-water heat-exchangers and protection philosophy used in SNR-2 is also given

  17. The SNR-300 steam generator small leak detection system

    International Nuclear Information System (INIS)

    Dumm, K.

    1984-01-01

    Small leak detection in the SNR-300 steam generator moduls is achieved by hydrogen meters. Development and design of the Nickel membrane - ion getter pump combination are described and sensitivity requests derived. Results of calibration tests by water/steam injections in a sodium loop are presented. The arrangement and interconnection of signals in SNR-300 are given and possibilities for inservice calibrations are discussed, supported by long time operation tests in the KNK-reactor plant. (author)

  18. The effect of SNR structure on non-equilibrium X-ray spectra

    International Nuclear Information System (INIS)

    Hamilton, A.J.S.; Sarazin, C.L.

    1983-01-01

    A technique is presented for characterizing the ionization structure and consequent thermal X-ray emission of a SNR when non-equilibrium ionization effects are important. The technique allows different theoretical SNR models to be compared and contrasted rapidly in advance of detailed numerical computations. In particular it is shown that the spectrum of a Sedov remnant can probably be applied satisfactorily in a variety of SNR structures, including the reverse shock model advocated by Chevalier (1982) for Type I SN, the isothermal similarity solution of Solinger, Rappaport and Buff (1975), and various inhomogenous or 'messy' structures. (Auth.)

  19. Detection of local sodium boiling in the nuclear boiling generator in KNK II and in the cores of SNR 300 and SNR 2

    International Nuclear Information System (INIS)

    Erhardt, J.; Hoppe, P.

    1977-03-01

    As a basis of a global detection system, the detection of local boiling in sodium cooled reactors via surveillance of the neutron flux background noise is of special importance. With the help of parameter studies it is investigated in the present report, which parts of the core of SNR 300 and SNR 2 could be monitored with such a detection system. As a comparison the detection sensibility of the planned boiling generator in KNK II is determined

  20. Boosting the SNR by adding a receive-only endorectal monopole to an external antenna array for high-resolution, T2 -weighted imaging of early-stage cervical cancer with 7-T MRI

    NARCIS (Netherlands)

    van Kalleveen, I.M.L.; Hoogendam, J.P.; Raaijmakers, A.J.E.; Visser, F.; Arteaga de Castro, C.S.; Verheijen, R.H.M.; Luijten, P.R.; Zweemer, R.P.; Veldhuis, W.B.; Klomp, D.W.J.

    The aim of this study was to investigate the signal-to-noise ratio (SNR) gain in early-stage cervical cancer at ultrahigh-field MRI (e.g. 7 T) using a combination of multiple external antennas and a single endorectal antenna. In particular, we used an endorectal monopole antenna to increase the SNR

  1. Core design aspects of SNR 2

    International Nuclear Information System (INIS)

    Wehmann, U.K.

    1987-01-01

    The paper describes in its first part the main characteristics of the core of the SNR 2 fast breeder reactor which is being planned within the European collaboration on fast breeder reactors. In the second part some core design aspects are discussed. The fuel element management with an inwards shuffling after each cycle is illustrated which offers advantages with respect to linear rating, steel damage and average discharge burnup. For this management, the full three-dimensional power and burnup history has been calculated and some typical results are presented. The shutdown requirements and the capabilities of the two shutdown systems of SNR 2 are discussed. The necessity for a reliable surveillance of the power distribution is demonstrated by the pronounced power tilts in case of the unintentional withdrawal of an absorber rod. Finally, a short review of the main nuclear design methods and their validation with help of the evaluation of experiments in zero power facilities and power reactors is given

  2. Optimize the Power Consumption and SNR of the 3D Photonic High-Radix Switch Architecture Based on Extra Channels and Redundant Rings

    Directory of Open Access Journals (Sweden)

    Jie Jian

    2018-01-01

    Full Text Available The demand from exascale computing has made the design of high-radix switch chips an attractive and challenging research field in EHPC (exascale high-performance computing. The static power, due to the thermal sensitivity and process variation of the microresonator rings, and the cross talk noise of the optical network become the main bottlenecks of the network’s scalability. This paper proposes the analyze model of the trimming power, process variation power, and signal-to-noise ratio (SNR for the Graphein-based high-radix optical switch networks and uses the extra channels and the redundant rings to decrease the trimming power and the process variation power. The paper also explores the SNR under different configurations. The simulation result shows that when using 8 extra channels in the 64×64 crossbar optical network, the trimming power reduces almost 80% and the process variation power decreases 65% by adding 16 redundant rings in the 64×64 crossbar optical network. All of these schemes have little influence on the SNR. Meanwhile, the greater channel spacing has great advantages to decrease the static power and increase the SNR of the optical network.

  3. A novel technique for determination of two dimensional signal-to-noise ratio improvement factor of an antiscatter grid in digital radiography

    Science.gov (United States)

    Nøtthellen, Jacob; Konst, Bente; Abildgaard, Andreas

    2014-08-01

    Purpose: to present a new and simplified method for pixel-wise determination of the signal-to-noise ratio improvement factor KSNR of an antiscatter grid, when used with a digital imaging system. The method was based on approximations of published formulas. The simplified estimate of K2SNR may be used as a decision tool for whether or not to use an antiscatter grid. Methods: the primary transmission of the grid Tp was determined with and without a phantom present using a pattern of beam stops. The Bucky factor B was measured with and without a phantom present. Hence K2SNR maps were created based on Tp and B. A formula was developed to calculate K2SNR from the measured Bs without using the measured Tp. The formula was applied on two exposures of anthropomorphic phantoms, adult legs and baby chest, and on two homogeneous poly[methyl methacrylate] (PMMA) phantoms, 5 cm and 10 cm thick. The results from anthropomorphic phantoms were compared to those based on the beam stop method. The results for the PMMA-phantoms were compared to a study that used a contrast-detail phantom. Results: 2D maps of K2SNR over the entire adult legs and baby chest phantoms were created. The maps indicate that it is advantageous to use the antiscatter grid for imaging of the adult legs. For baby chest imaging the antiscatter grid is not recommended if only the lung regions are of interest. The K2SNR maps based on the new method correspond to those from the beam stop method, and the K2SNR from the homogenous phantoms arising from two different approaches also agreed well with each other. Conclusion: a method to measure 2D K2SNR associated with grid use in digital radiography system was developed and validated. The proposed method requires four exposures and use of a simple formula. It is fast and provides adequate estimates for K2SNR.

  4. Secure diversity-multiplexing tradeoff of zero-forcing transmit scheme at finite-SNR

    KAUST Repository

    Rezki, Zouheir; Alouini, Mohamed-Slim

    2012-01-01

    information in the orthogonal space of the eavesdropper channel, is used. First, we introduce the secrecy multiplexing gain at finite-SNR that generalizes the definition at high-SNR. Then, we provide upper and lower bounds on the outage probability under

  5. Sodium magnetic resonance imaging. Development of a 3D radial acquisition technique with optimized k-space sampling density and high SNR-efficiency; Natrium-Magnetresonanztomographie. Entwicklung einer 3D radialen Messtechnik mit optimierter k-Raum-Abtastdichte und hoher SNR-Effizienz

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, Armin Michael

    2009-04-01

    A 3D radial k-space acquisition technique with homogenous distribution of the sampling density (DA-3D-RAD) is presented. This technique enables short echo times (TE<0.5 ms), that are necessary for {sup 23}Na-MRI, and provides a high SNR-efficiency. The gradients of the DA-3D-RAD-sequence are designed such that the average sampling density in each spherical shell of k-space is constant. The DA-3D-RAD-sequence provides 34% more SNR than a conventional 3D radial sequence (3D-RAD) if T{sub 2}{sup *}-decay is neglected. This SNR-gain is enhanced if T{sub 2}{sup *}-decay is present, so a 1.5 to 1.8 fold higher SNR is measured in brain tissue with the DA-3D-RAD-sequence. Simulations and experimental measurements show that the DA-3D-RAD sequence yields a better resolution in the presence of T{sub 2}{sup *}-decay and less image artefacts when B{sub 0}-inhomogeneities exist. Using the developed sequence, T{sub 1}-, T{sub 2}{sup *}- and Inversion-Recovery-{sup 23}Na-image contrasts were acquired for several organs and {sup 23}Na-relaxation times were measured (brain tissue: T{sub 1}=29.0{+-}0.3 ms; T{sub 2s}{sup *}{approx}4 ms; T{sub 2l}{sup *}{approx}31 ms; cerebrospinal fluid: T{sub 1}=58.1{+-}0.6 ms; T{sub 2}{sup *}=55{+-}3 ms (B{sub 0}=3 T)). T{sub 1}- und T{sub 2}{sup *}-relaxation times of cerebrospinal fluid are independent of the selected magnetic field strength (B0 = 3T/7 T), whereas the relaxation times of brain tissue increase with field strength. Furthermore, {sup 23}Na-signals of oedemata were suppressed in patients and thus signals from different tissue compartments were selectively measured. (orig.)

  6. Performance of the split-symbol moments SNR estimator in the presence of inter-symbol interference

    Science.gov (United States)

    Shah, B.; Hinedi, S.

    1989-01-01

    The Split-Symbol Moments Estimator (SSME) is an algorithm that is designed to estimate symbol signal-to-noise ratio (SNR) in the presence of additive white Gaussian noise (AWGN). The performance of the SSME algorithm in band-limited channels is examined. The effects of the resulting inter-symbol interference (ISI) are quantified. All results obtained are in closed form and can be easily evaluated numerically for performance prediction purposes. Furthermore, they are validated through digital simulations.

  7. Development of a smartphone-based pulse oximeter with adaptive SNR/power balancing.

    Science.gov (United States)

    Phelps, Tom; Haowei Jiang; Hall, Drew A

    2017-07-01

    Millions worldwide suffer from diseases that exhibit early warnings signs that can be detected by standard clinical-grade diagnostic tools. Unfortunately, such tools are often prohibitively expensive to the developing world leading to inadequate healthcare and high mortality rates. To address this problem, a smartphone-based pulse oximeter is presented that interfaces with the phone through the audio jack, enabling point-of-care measurements of heart rate (HR) and oxygen saturation (SpO 2 ). The device is designed to utilize existing phone resources (e.g., the processor, battery, and memory) resulting in a more portable and inexpensive diagnostic tool than standalone equivalents. By adaptively tuning the LED driving signal, the device is less dependent on phone-specific audio jack properties than prior audio jack-based work making it universally compatible with all smartphones. We demonstrate that the pulse oximeter can adaptively optimize the signal-to-noise ratio (SNR) within the power constraints of a mobile phone (<; 10mW) while maintaining high accuracy (HR error <; 3.4% and SpO 2 error <; 3.7%) against a clinical grade instrument.

  8. Recent radio studies of SNR

    International Nuclear Information System (INIS)

    Dickel, J.R.

    1983-01-01

    SNR can generally be recognized as extended sources of continuum radio emission with non-thermal spectra located near the galactic plane. The author describes the kinds of observations currently being obtained and what they tell us about the objects. The data include continuum observations which can reach resolutions of about 1 arcsec using aperture synthesis techniques and also spectral line observations of the interstellar matter being encountered by the remnants. (Auth.)

  9. Use of reflected GNSS SNR data to retrieve either soil moisture or vegetation height from a wheat crop

    Directory of Open Access Journals (Sweden)

    S. Zhang

    2017-09-01

    Full Text Available This work aims to estimate soil moisture and vegetation height from Global Navigation Satellite System (GNSS Signal to Noise Ratio (SNR data using direct and reflected signals by the land surface surrounding a ground-based antenna. Observations are collected from a rainfed wheat field in southwestern France. Surface soil moisture is retrieved based on SNR phases estimated by the Least Square Estimation method, assuming the relative antenna height is constant. It is found that vegetation growth breaks up the constant relative antenna height assumption. A vegetation-height retrieval algorithm is proposed using the SNR-dominant period (the peak period in the average power spectrum derived from a wavelet analysis of SNR. Soil moisture and vegetation height are retrieved at different time periods (before and after vegetation's significant growth in March. The retrievals are compared with two independent reference data sets: in situ observations of soil moisture and vegetation height, and numerical simulations of soil moisture, vegetation height and above-ground dry biomass from the ISBA (interactions between soil, biosphere and atmosphere land surface model. Results show that changes in soil moisture mainly affect the multipath phase of the SNR data (assuming the relative antenna height is constant with little change in the dominant period of the SNR data, whereas changes in vegetation height are more likely to modulate the SNR-dominant period. Surface volumetric soil moisture can be estimated (R2  =  0.74, RMSE  =  0.009 m3 m−3 when the wheat is smaller than one wavelength (∼ 19 cm. The quality of the estimates markedly decreases when the vegetation height increases. This is because the reflected GNSS signal is less affected by the soil. When vegetation replaces soil as the dominant reflecting surface, a wavelet analysis provides an accurate estimation of the wheat crop height (R2  =  0.98, RMSE  =  6

  10. Signal-to-noise ratio application to seismic marker analysis and fracture detection

    Science.gov (United States)

    Xu, Hui-Qun; Gui, Zhi-Xian

    2014-03-01

    Seismic data with high signal-to-noise ratios (SNRs) are useful in reservoir exploration. To obtain high SNR seismic data, significant effort is required to achieve noise attenuation in seismic data processing, which is costly in materials, and human and financial resources. We introduce a method for improving the SNR of seismic data. The SNR is calculated by using the frequency domain method. Furthermore, we optimize and discuss the critical parameters and calculation procedure. We applied the proposed method on real data and found that the SNR is high in the seismic marker and low in the fracture zone. Consequently, this can be used to extract detailed information about fracture zones that are inferred by structural analysis but not observed in conventional seismic data.

  11. MIMO Intensity-Modulation Channels: Capacity Bounds and High SNR Characterization

    KAUST Repository

    Chaaban, Anas

    2016-10-01

    The capacity of MIMO intensity modulation channels is studied. The nonnegativity of the transmit signal (intensity) poses a challenge on the precoding of the transmit signal, which limits the applicability of classical schemes in this type of channels. To resolve this issue, capacity lower bounds are developed by using precoding-free schemes. This is achieved by channel inversion or QR decomposition to convert the MIMO channel to a set of parallel channels. The achievable rate of a DC-offset SVD based scheme is also derived as a benchmark. Then, a capacity upper bound is derived and is shown to coincide with the achievable rate of the QR decomposition based scheme at high SNR, consequently characterizing the high-SNR capacity of the channel. The high-SNR gap between capacity and the achievable rates of the channel inversion and the DC-offset SVD based schemes is also characterized. Finally, the ergodic capacity of the channel is also briefly discussed.

  12. Comparison of entrance exposure and signal-to-noise ratio between an SBDX prototype and a wide-beam cardiac angiographic system

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Wilfley, Brian P.; Star-Lack, Josh M.; Heanue, Joseph A.; Betts, Timothy D.; Van Lysel, Michael S.

    2006-01-01

    The scanning-beam digital x-ray (SBDX) system uses an inverse geometry, narrow x-ray beam, and a 2-mm thick CdTe detector to improve the dose efficiency of the coronary angiographic procedure. Entrance exposure and large-area iodine signal-to-noise ratio (SNR) were measured with the SBDX prototype and compared to that of a clinical cardiac interventional system with image intensifier (II) and charge coupled device (CCD) camera (Philips H5000, MRC-200 x-ray tube, 72 kWp max). Phantoms were 18.6-35.0 cm acrylic with an iohexol-equivalent disk placed at midthickness (35 mg/cm 2 iodine radiographic density). Imaging was performed at 15 frame/s, with the disk at mechanical isocenter and an 11-cm object-plane field width. The II/CCD system was operated in cine mode with automatic exposure control. With the SBDX prototype at maximum x-ray output (120 kVp, 24.3 kWp), the SBDX SNR was 107%-69% of the II/CCD SNR, depending on phantom thickness, and the SBDX entrance exposure rate was 10.7-9.3 R/min (9.4-8.2 cGy/min air kerma). For phantoms where an equal-kVp imaging comparison was possible (≥23.3 cm), the SBDX SNR ranged from 47% to 69% of the II/CCD SNR while delivering 6% to 9% of the II/CCD entrance exposure rate. From these measurements it was determined that the relative SBDX entrance exposure at equal SNR would be 31%-16%. Results were consistent with a model for relative entrance exposure at equal SNR, which predicted a 3-7 times reduction in entrance exposure due to SBDX's comparatively low scatter fraction (5.5%-8.1% measured, including off-focus radiation), high detector detective quantum efficiency (66%-73%, measured from 70 to 120 kVp), and large entrance field area (1.7x-2.3x, for the same object-plane field width). With improvements to the system geometry, detector, and x-ray source, SBDX technology is projected to achieve conventional cine-quality SNR over a full range of patient thicknesses, with 5-10 times lower skin dose

  13. A model of SNR evolution for an O-star in a cloudy ISM

    International Nuclear Information System (INIS)

    Shull, P. Jr.

    1988-01-01

    The authors present an analytical model of SNR evolution in a cloudy interstellar medium for a single progenitor star of spectral type 05 V. The model begins with the progenitor on the zero-age main sequence, includes the effects of the star's wind and ionizing photons, and ends with the SNR's assimilation by the ISM. The authors assume that the ISM consists of atomic clouds, molecular clouds, and a hot intercloud phase. The type of SNR that results bears a strong resemblance to N63A in the Large Magellanic Cloud

  14. Measurement of moisture motion under a temperature gradient in a concrete for SNR-300 using thermal neutrons

    International Nuclear Information System (INIS)

    Zelinger, A.

    1975-01-01

    For describing the behavior of the moisture in the concrete of the containment of SNR-300 in a hypothetical accident parameters were determined experimentally. The method is based on transmission of thermal neutrons through a plate of concrete. When a temperature of 170 deg C was applied at one end of the plate migration of moisture and evaporation took place. This could be observed by neutron radiography giving a gross picture of moisture migration. Furthermore the intensity of the transmitted neutron beam was measured with a neutron counter. From these values profiles of the change of moisture concentration could be obtained with a spatial resolution of few millimeters. The method used is entirely different from the conventional moisture meters which use fast neutrons. From the experimental data the mass transfer coefficient of vapour, the diffusion coefficient of vapour in concrete and the porosity of the concrete could be determined

  15. Investigation of the signal-to-noise ratio on a state-of-the-art PET system: measurements with the EEC whole-body phantom

    International Nuclear Information System (INIS)

    Jaegel, M.; Adam, L.E.; Bellemann, M.E.; Zaers, J.; Trojan, H.; Brix, G.; Rauschnabel, K.

    1998-01-01

    Aim: The spatial resolution of PET scanners can be improved by using smaller detector elements. This approach, however, results in poorer counting statistics of the reconstructed images. Therefore, the aim of this study was to investigate the influence of different acquisition parameters on the signal-to-noise ratio (SNR) and thus to optimize PET image quality. Methods: The experiments were performed with the latest-generation whole-body PET system (ECAT Exact HR + , Siemens/CTI) using the standard 2D and 3D data acquisition parameters recommended by the manufacturer. The EEC whole-body phantom with different inserts was used to simulate patient examinations of the thorax. Emission and transmission scans were acquired with varying numbers of events and at different settings of the lower level energy discriminator. The influence of the number of counts on the SNR was parameterized using a simple model function. Results: For count rates frequently encountered in clinical PET studies, the emission scan has a stronger influence on the SNR in the reconstructed image than the transmission scan. The SNR can be improved by using a higher setting of the lower energy level provided that the total number of counts is kept constant. Based on the established model function, the relative duration of the emission scan with respect to the total acquistion time was optimized, yielding a value of about 75% for both the 2D and 3D mode. Conclusion: The presented phenomenological approach can readily be employed to optimize the SNR and thus the quality of PET images acquired at different scanners or with different examination protocols. (orig.) [de

  16. Influence of detector collimation on SNR in four different MDCT scanners using a reconstructed slice thickness of 5 mm

    International Nuclear Information System (INIS)

    Verdun, F.R.; Pachoud, M.; Monnin, P.; Valley, J.-F.; Noel, A.; Meuli, R.; Schnyder, P.; Denys, A.

    2004-01-01

    The purpose of this paper is to compare the influence of detector collimation on the signal-to-noise ratio (SNR) for a 5.0 mm reconstructed slice thickness for four multi-detector row CT (MDCT) units. SNRs were measured on Catphan test phantom images from four MDCT units: a GE LightSpeed QX/I, a Marconi MX 8000, a Toshiba Aquilion and a Siemens Volume Zoom. Five-millimetre-thick reconstructed slices were obtained from acquisitions performed using detector collimations of 2.0-2.5 mm and 5.0 mm, 120 kV, a 360 tube rotation time of 0.5 s, a wide range of mA and pitch values in the range of 0.75-0.85 and 1.25-1.5. For each set of acquisition parameters, a Wiener spectrum was also calculated. Statistical differences in SNR for the different acquisition parameters were evaluated using a Student's t-test (P<0.05). The influence of detector collimation on the SNR for a 5.0-mm reconstructed slice thickness is different for different MDCT scanners. At pitch values lower than unity, the use of a small detector collimation to produce 5.0-mm thick slices is beneficial for one unit and detrimental for another. At pitch values higher than unity, using a small detector collimation is beneficial for two units. One manufacturer uses different reconstruction filters when switching from a 2.5- to a 5.0-mm detector collimation. For a comparable reconstructed slice thickness, using a smaller detector collimation does not always reduce image noise. Thus, the impact of the detector collimation on image noise should be determined by standard deviation calculations, and also by assessing the power spectra of the noise. (orig.)

  17. [Evaluation of signal noise ratio on analysis of clear cell renal cell carcinoma using DWI with multi-b values].

    Science.gov (United States)

    Ding, Jiule; Xing, Wei; Chen, Jie; Dai, Yongming; Sun, Jun; Li, Dengfa

    2014-01-21

    To explore the influence of signal noise ratio (SNR) on analysis of clear cell renal cell carcinoma (CCRCC) using DWI with multi-b values. The images of 17 cases with CCRCC were analyzed, including 17 masses and 9 pure cysts. The signal intensity of the cysts and masses was measured separately on DWI for each b value. The minimal SNR, as the threshold, was recorded when the signal curve manifest as the single exponential line. The SNR of the CCRCC was calculated on DWI for each b value, and compared with the threshold by independent Two-sample t Test. The signal decreased on DWI with increased b factors for both pure cysts and CCRCC. The threshold is 1.29 ± 0.17, and the signal intensity of the cysts on DWI with multi-b values shown as a single exponential line when b ≤ 800 s/mm(2). For the CCRCC, the SNR is similar to the threshold when b = 1 000 s/mm(2) (t = 0.40, P = 0.69), and is lower when b = 1 200 s/mm(2) (t = -2.38, P = 0.03). The SNR should be sufficient for quantitative analysis of DWI, and the maximal b value is 1000 s/mm(2) for CCRCC.

  18. THE NEUTRAL INTERSTELLAR GAS TOWARD SNR W44: CANDIDATES FOR TARGET PROTONS IN HADRONIC {gamma}-RAY PRODUCTION IN A MIDDLE-AGED SUPERNOVA REMNANT

    Energy Technology Data Exchange (ETDEWEB)

    Yoshiike, S.; Fukuda, T.; Sano, H.; Ohama, A.; Moribe, N.; Torii, K.; Hayakawa, T.; Okuda, T.; Yamamoto, H.; Mizuno, N.; Onishi, T.; Fukui, Y. [Department of Physics and Astrophysics, Nagoya University, Nagoya, Aichi 464-8602 (Japan); Tajima, H.; Maezawa, H.; Mizuno, A. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya, Aichi 464-8601 (Japan); Nishimura, A.; Kimura, K.; Ogawa, H. [Department of Astrophysics, Graduate School of Science, Osaka Prefecture University, 1-1 Gakuen-cho, Naka-ku, Sakai, Osaka 599-8531 (Japan); Giuliani, A. [INAF-IASF Milano, via E. Bassini 15, I-20133 Milano (Italy); Koo, B.-C., E-mail: yoshiike@a.phys.nagoya-u.ac.jp [Seoul National University, Seoul 151-742 (Korea, Republic of)

    2013-05-10

    We present an analysis of the interstellar medium (ISM) toward the {gamma}-ray supernova remnant (SNR) W44. We used NANTEN2 {sup 12}CO(J = 2-1) and {sup 12}CO(J = 1-0) data and Arecibo H I data in order to identify the molecular and atomic gas in the SNR. We confirmed that the molecular gas is located in the SNR shell with a primary peak toward the eastern edge of the shell. We newly identified high-excitation molecular gas along the eastern shell of the SNR in addition to the high-excitation broad gas previously observed inside the shell; the line intensity ratio between the {sup 12}CO(J = 2-1) and {sup 12}CO(J = 1-0) transitions in these regions is greater than {approx}1.0, suggesting a kinetic temperature of 30 K or higher, which is most likely due to heating by shock interaction. By comparing the ISM with {gamma}-rays, we find that target protons of hadronic origin are dominated by molecular protons of average density around 200 cm{sup -3}, where the possible contribution of atomic protons is 10% or less. This average density is consistent with the recent discovery of the low-energy {gamma}-rays suppressed in 50 MeV-10 GeV as observed with AGILE and Fermi. The {gamma}-ray spectrum differs from place to place in the SNR, suggesting that the cosmic-ray (CR) proton spectrum significantly changes within the middle-aged SNR perhaps due to the energy-dependent escape of CR protons from the acceleration site. We finally derive a total CR proton energy of {approx}10{sup 49} erg, consistent with the SN origin of the majority of the CRs in the Galaxy.

  19. On the capacity of Rician fading channels with full channel state information at low SNR

    KAUST Repository

    Rezki, Zouheir

    2012-06-01

    The capacity of flat Rayleigh fading channels with full channel state information (CSI) at the transmitter and at the receiver at asymptotically low SNR has been recently shown to scale essentially as SNR log (1/SNR). In this paper, we investigate the Rician fading channel capacity with full CSI, and show that the capacity of this channel scales essentially as 1/1+K SNR log (1 /SNR), where K is the Rician factor. This characterization includes perfect CSI at both the transmitter and the receiver or noisy CSI at the transmitter and perfect CSI at the receiver. We also show that one-bit CSI at the transmitter is enough to achieve this asymptotic capacity using an On-Off power control scheme. Our framework may be seen as a generalization of previous works as it captures the Rayleigh fading channel as a special case by letting K goes to zero. © 2012 IEEE.

  20. Radiometric and signal-to-noise ratio properties of multiplex dispersive spectrometry

    International Nuclear Information System (INIS)

    Barducci, Alessandro; Guzzi, Donatella; Lastri, Cinzia; Nardino, Vanni; Marcoionni, Paolo; Pippi, Ivan

    2010-01-01

    Recent theoretical investigations have shown important radiometric disadvantages of interferential multiplexing in Fourier transform spectrometry that apparently can be applied even to coded aperture spectrometers. We have reexamined the methods of noninterferential multiplexing in order to assess their signal-to-noise ratio (SNR) performance, relying on a theoretical modeling of the multiplexed signals. We are able to show that quite similar SNR and radiometric disadvantages affect multiplex dispersive spectrometry. The effect of noise on spectral estimations is discussed.

  1. Reactivity feedback evaluation of material relocations in the CABRI-1 experiments with fuel worth distributions from SNR-300

    International Nuclear Information System (INIS)

    Royl, P.; Pfrang, W.; Struwe, D.

    1991-01-01

    The fuel relocations from the CABRI-1 experiments with irradiated fuel that had been evaluated from the hodoscope measurements were used together with fuel reactivity worth distributions from the SNR-300 to estimate the reactivity effect which these motions would have if they occurred in SNR-300 at the same relative distance to the peak power as in CABRI. The procedure for the reactivity evaluation is outlined including the assumptions made for fuel mass conservation. The results show that the initial fuel motion yields always negative reactivities. They also document the mechanism for a temporary reactivity increase by in-pin fuel flow in some transient overpower tests. This mechanism, however, never dominates, because material accumulates always sufficiently above the peak power point. Thus, the late autocatalytic amplifications of voiding induced power excursions by compactive in-pin fuel flow, that had been simulated in bounding loss of flow analyses for SNR-300, have no basis at all when considering the results from the CABRI-1 experiments

  2. Verification of the directivity index and other measures of directivity in predicting directional benefit

    Science.gov (United States)

    Dittberner, Andrew; Bentler, Ruth

    2005-09-01

    The relationship between various directivity measures and subject performance with directional microphone hearing aids was determined. Test devices included first- and second-order directional microphones. Recordings of sentences and noise (Hearing in Noise Test, HINT) were made through each test device in simple, complex, and anisotropic background noise conditions. Twenty-six subjects, with normal hearing, were administered the HINT test recordings, and directional benefit was computed. These measures were correlated to theoretical, free-field, and KEMAR DI values, as well as front-to-back ratios, in situ SNRs, and a newly proposed Db-SNR, wherein a predictive value of the SNR improvement is calculated as a function of the noise source incidence. The different predictive scores showed high correlation to the measured directional benefit scores in the complex (diffuse-like) background noise condition (r=0.89-0.97, pThe Db-SNR approach and the in situ SNR measures provided excellent prediction of subject performance in all background noise conditions (0.85-0.97, pthe predictive measures could account for the effects of reverberation on the speech signal (r=0.35-0.40, p<0.05).

  3. On the capacity of nakagami-m fading Channels with full channel state information at low SNR

    KAUST Repository

    Rezki, Zouheir

    2012-06-01

    The capacity of flat Rayleigh fading channels with full channel state information (CSI) at the transmitter and at the receiver at asymptotically low SNR has been recently shown to scale essentially as SNR log(1/SNR)}. In this paper, we investigate the Nakagami-m fading channel capacity with full CSI, and show that the capacity of this channel scales essentially as m/ Omega SNR log(1/SNR), where m is the Nakagami-m fading parameter and where Ω is the channel mean-square. We also show that one-bit CSI at the transmitter is enough to achieve this asymptotic capacity using an On-Off power control scheme. Our framework may be seen as a generalization of previous works as it captures the Rayleigh fading channel as a special case by taking m=1. © 2012 IEEE.

  4. SNR-steam generator design with respect to large sodium water reactions

    International Nuclear Information System (INIS)

    Jong, J.J. de; Kellner, A.; Florie, C.J.L.

    1984-01-01

    This paper deals with the experiences gained during the licensing procedure for the steam generators for the SNR 300 LMFBR regarding large sodium-water reactions. A description is given of the different calculations executed to investigate the effects of large leaks on the 85 MW helical coiled and straight tube steam generators. The investigations on the helical coiled steam generators are divided in the formulations of fluid behaviour, dynamic force calculations, dynamic response calculation and finally stress analyses. Several results are shown. The investigations on the straight tube steam generators are performed using models describing fluid-structure interaction, coupled with stress analyses. Several results are presented. A description is given of the problems and necessary construction changes during the licensing process. Advises are given for future analyses and design concepts for second generation commercial size LMFBR steam generators with respect to large leaks; based on the experience, gained with SNR 300, and using some new calculations for SNR 2. (author)

  5. Using image quality measures and features to choose good images for classification of ISAR imagery

    CSIR Research Space (South Africa)

    Steyn, JM

    2014-10-01

    Full Text Available the quality measures and to determine the minimum dwell-time for ISAR image formation. Keywords—ISAR (inverse synthetic aperture radar), Dwell-time, Quality Measure, Image Contrast, Image Entropy, SNR (signal-to-noise ratio), Maritime Vessels ...

  6. Steam generator in the SNR-project

    International Nuclear Information System (INIS)

    van Westenbrugge, J.K.

    1979-01-01

    The design philosophy of steam generators for 1300 MWe LMFBR's is presented. The basis for this philosophy is the present experience with the licensing of the SNR-300. This experience is reported. The approach for the steam generators for the 1300 MWe LMFBR is elaborated on, both for accident prevention and damage limitation, for the component itself as well as for the system design. Both Design Base Accident and Hypothetical Accidents are discussed. 8 refs

  7. The Effect of Signal-to-Noise Ratio on Linguistic Processing in a Semantic Judgment Task: An Aging Study.

    Science.gov (United States)

    Stanley, Nicholas; Davis, Tara; Estis, Julie

    2017-03-01

    Aging effects on speech understanding in noise have primarily been assessed through speech recognition tasks. Recognition tasks, which focus on bottom-up, perceptual aspects of speech understanding, intentionally limit linguistic and cognitive factors by asking participants to only repeat what they have heard. On the other hand, linguistic processing tasks require bottom-up and top-down (linguistic, cognitive) processing skills and are, therefore, more reflective of speech understanding abilities used in everyday communication. The effect of signal-to-noise ratio (SNR) on linguistic processing ability is relatively unknown for either young (YAs) or older adults (OAs). To determine if reduced SNRs would be more deleterious to the linguistic processing of OAs than YAs, as measured by accuracy and reaction time in a semantic judgment task in competing speech. In the semantic judgment task, participants indicated via button press whether word pairs were a semantic Match or No Match. This task was performed in quiet, as well as, +3, 0, -3, and -6 dB SNR with two-talker speech competition. Seventeen YAs (20-30 yr) with normal hearing sensitivity and 17 OAs (60-68 yr) with normal hearing sensitivity or mild-to-moderate sensorineural hearing loss within age-appropriate norms. Accuracy, reaction time, and false alarm rate were measured and analyzed using a mixed design analysis of variance. A decrease in SNR level significantly reduced accuracy and increased reaction time in both YAs and OAs. However, poor SNRs affected accuracy and reaction time of Match and No Match word pairs differently. Accuracy for Match pairs declined at a steeper rate than No Match pairs in both groups as SNR decreased. In addition, reaction time for No Match pairs increased at a greater rate than Match pairs in more difficult SNRs, particularly at -3 and -6 dB SNR. False-alarm rates indicated that participants had a response bias to No Match pairs as the SNR decreased. Age-related differences were

  8. Signal-to-Noise Ratio in PVT Performance as a Cognitive Measure of the Effect of Sleep Deprivation on the Fidelity of Information Processing.

    Science.gov (United States)

    Chavali, Venkata P; Riedy, Samantha M; Van Dongen, Hans P A

    2017-03-01

    There is a long-standing debate about the best way to characterize performance deficits on the psychomotor vigilance test (PVT), a widely used assay of cognitive impairment in human sleep deprivation studies. Here, we address this issue through the theoretical framework of the diffusion model and propose to express PVT performance in terms of signal-to-noise ratio (SNR). From the equations of the diffusion model for one-choice, reaction-time tasks, we derived an expression for a novel SNR metric for PVT performance. We also showed that LSNR-a commonly used log-transformation of SNR-can be reasonably well approximated by a linear function of the mean response speed, LSNRapx. We computed SNR, LSNR, LSNRapx, and number of lapses for 1284 PVT sessions collected from 99 healthy young adults who participated in laboratory studies with 38 hr of total sleep deprivation. All four PVT metrics captured the effects of time awake and time of day on cognitive performance during sleep deprivation. The LSNR had the best psychometric properties, including high sensitivity, high stability, high degree of normality, absence of floor and ceiling effects, and no bias in the meaning of change scores related to absolute baseline performance. The theoretical motivation of SNR and LSNR permits quantitative interpretation of PVT performance as an assay of the fidelity of information processing in cognition. Furthermore, with a conceptual and statistical meaning grounded in information theory and generalizable across scientific fields, LSNR in particular is a useful tool for systems-integrated fatigue risk management. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  9. A consistency evaluation of signal-to-noise ratio in the quality assessment of human brain magnetic resonance images.

    Science.gov (United States)

    Yu, Shaode; Dai, Guangzhe; Wang, Zhaoyang; Li, Leida; Wei, Xinhua; Xie, Yaoqin

    2018-05-16

    Quality assessment of medical images is highly related to the quality assurance, image interpretation and decision making. As to magnetic resonance (MR) images, signal-to-noise ratio (SNR) is routinely used as a quality indicator, while little knowledge is known of its consistency regarding different observers. In total, 192, 88, 76 and 55 brain images are acquired using T 2 * , T 1 , T 2 and contrast-enhanced T 1 (T 1 C) weighted MR imaging sequences, respectively. To each imaging protocol, the consistency of SNR measurement is verified between and within two observers, and white matter (WM) and cerebral spinal fluid (CSF) are alternately used as the tissue region of interest (TOI) for SNR measurement. The procedure is repeated on another day within 30 days. At first, overlapped voxels in TOIs are quantified with Dice index. Then, test-retest reliability is assessed in terms of intra-class correlation coefficient (ICC). After that, four models (BIQI, BLIINDS-II, BRISQUE and NIQE) primarily used for the quality assessment of natural images are borrowed to predict the quality of MR images. And in the end, the correlation between SNR values and predicted results is analyzed. To the same TOI in each MR imaging sequence, less than 6% voxels are overlapped between manual delineations. In the quality estimation of MR images, statistical analysis indicates no significant difference between observers (Wilcoxon rank sum test, p w  ≥ 0.11; paired-sample t test, p p  ≥ 0.26), and good to very good intra- and inter-observer reliability are found (ICC, p icc  ≥ 0.74). Furthermore, Pearson correlation coefficient (r p ) suggests that SNR wm correlates strongly with BIQI, BLIINDS-II and BRISQUE in T 2 * (r p  ≥ 0.78), BRISQUE and NIQE in T 1 (r p  ≥ 0.77), BLIINDS-II in T 2 (r p  ≥ 0.68) and BRISQUE and NIQE in T 1 C (r p  ≥ 0.62) weighted MR images, while SNR csf correlates strongly with BLIINDS-II in T 2 * (r p  ≥ 0.63) and in T

  10. The single SNR fuel assembly container (ESBB) to transport unirradiated SNR 300 fuel assemblies

    International Nuclear Information System (INIS)

    Hilbert, F.; Hottenrott, G.

    1998-01-01

    In this paper a new type B(U) package design is presented. The Single SNR Fuel Assembly Container (ESBB) is designed for the transport and storage of a single SNR 300 fuel assembly. This package is the main component for the future interim storage of the fuel assemblies in heavy storage casks. Its benefits are that it is compatible with the Category I transport system of Nuclear Cargo + Service NCS) used in Germany and that it can be easily handled at the current storage locations as well as in an interim storage facility. In total 205 fuel assemblies are currently stored in Hanau, Germany and Dounreay, U.K. Former studies have shown, that heavy transport and storage casks can be handled there only with considerable efforts. But the required category I transport to an interim storage is not reasonably feasible. To overcome these problems the ESBB was designed. It consists of a stainless steel tube with welded bottom, a welded plug as closure system and shock absorbers 26 packages at maximum can be transported in one batch with the NCS security vehicle. The safety analysis shows that the package complies with IAEA 1996. Standard calculations methods and computer codes like HEATING 7.2 (Childs 1993) have been used for the analysis. Criticality safety assessment is based on conservative assumptions as required in IAEA 1996. Drop tests carried out by BAM will be used to verify the design. These tests are scheduled for mid 1998. For the validation of the design prototypes have already been manufactured. Handling tests show that the design complies with the requirements. Preliminary drop tests show that the certification drop tests will be passed positively. (authors)

  11. Sodium magnetic resonance imaging. Development of a 3D radial acquisition technique with optimized k-space sampling density and high SNR-efficiency

    International Nuclear Information System (INIS)

    Nagel, Armin Michael

    2009-01-01

    A 3D radial k-space acquisition technique with homogenous distribution of the sampling density (DA-3D-RAD) is presented. This technique enables short echo times (TE 23 Na-MRI, and provides a high SNR-efficiency. The gradients of the DA-3D-RAD-sequence are designed such that the average sampling density in each spherical shell of k-space is constant. The DA-3D-RAD-sequence provides 34% more SNR than a conventional 3D radial sequence (3D-RAD) if T 2 * -decay is neglected. This SNR-gain is enhanced if T 2 * -decay is present, so a 1.5 to 1.8 fold higher SNR is measured in brain tissue with the DA-3D-RAD-sequence. Simulations and experimental measurements show that the DA-3D-RAD sequence yields a better resolution in the presence of T 2 * -decay and less image artefacts when B 0 -inhomogeneities exist. Using the developed sequence, T 1 -, T 2 * - and Inversion-Recovery- 23 Na-image contrasts were acquired for several organs and 23 Na-relaxation times were measured (brain tissue: T 1 =29.0±0.3 ms; T 2s * ∼4 ms; T 2l * ∼31 ms; cerebrospinal fluid: T 1 =58.1±0.6 ms; T 2 * =55±3 ms (B 0 =3 T)). T 1 - und T 2 * -relaxation times of cerebrospinal fluid are independent of the selected magnetic field strength (B0 = 3T/7 T), whereas the relaxation times of brain tissue increase with field strength. Furthermore, 23 Na-signals of oedemata were suppressed in patients and thus signals from different tissue compartments were selectively measured. (orig.)

  12. Diffusion-weighted MRI of the prostate at 3.0 T: comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI-The impact of SNR on ADC measurement.

    Science.gov (United States)

    Mazaheri, Yousef; Vargas, H Alberto; Nyman, Gregory; Shukla-Dave, Amita; Akin, Oguz; Hricak, Hedvig

    2013-10-01

    To compare ADC values measured from diffusion-weighted MR (DW-MR) images of the prostate obtained with both endorectal and phased-array coils (ERC+PAC) to those from DW-MRI images obtained with an eight-channel torso phased-array coil (PAC) at 3.0 T. The institutional review board issued a waiver of informed consent for this HIPAA-compliant study. Twenty-five patients with biopsy-proven prostate cancer underwent standard 3-T MRI using 2 different coil arrangements (ERC+PAC and PAC only) in the same session. DW-MRI at five b-values (0, 600, 1000, 1200, and 1500 s/mm(2)) were acquired using both coil arrangements. On b=0 images, signal-to-noise ratios (SNRs) were measured as the ratio of the mean signal from PZ and TZ ROIs to the standard deviation from the mean signal in an artifact-free ROI in the rectum. Matching regions-of-interest (ROIs) were identified in the peripheral zone and transition zone on ERC-MRI and PAC-MRI. For each ROI, mean ADC values for all zero and non-zero b-value combinations were computed. Mean SNR with ERC-MRI at PZ (66.33 ± 27.07) and TZ (32.69 ± 12.52) was 9.27 and 5.52 times higher than with PAC-MRI ((7.32 ± 2.30) and (6.13 ± 1.56), respectively) (PERC-MRI (PERC. To address these requirements, clinical MR systems should have image processing capabilities which incorporate the noise distribution. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. How should low-contrast detail detectability be measured in fluoroscopy?

    International Nuclear Information System (INIS)

    Tapiovaara, Markku J.; Sandborg, Michael

    2004-01-01

    The relationship and precision of four methods for measuring the low-contrast detail detectability in fluoroscopic imaging were studied. These included the physical measurement of the accumulation rate of the square of the signal-to-noise ratio (SNR rate 2 ), two-alternative forced-choice (2-AFC) experiments, sixteen-alternative forced-choice (16-AFC) experiments and subjective determination of the threshold contrast. The precision and sensitivity of the threshold contrast measurement were seen to be modest in the constancy testing of fluoroscopic equipment: only large changes in system performance could be reliably detected by that method. The measurement of the SNR rate 2 is suggested instead. The relationship between the results of the various methods were studied, and it was found that human performance can be related to SNR rate 2 by introducing the concept of the effective image information integration time (t eff ). When measured for an unlimited observation time, it depicts the saturation of human performance in detecting a static low-contrast detail in dynamic image noise. Here, t eff was found to be about 0.6 s in 2-AFC tests and 0.3 s in 16-AFC tests

  14. Measurement and analysis of vibrational behavior of an SNR-fuel element in sodium flow

    International Nuclear Information System (INIS)

    Hess, B.F.H.; Ruppert, E.; Schmidt, H.; Vinzens, K.

    1975-01-01

    Within the framework of SNR-300 fuel element development programme a complete full size fuel element dummy has been tested thoroughly for nearly 3000 hours at 650 deg C system temperature in the AKB sodium loop at Interatom, Bensberg. It is known that the coolant flow through a subassembly can induce flutter or vibrations of structural parts such as single pins, the wrapper and the total pin bundle all of which have been of interest during this test. To detect these vibrations of different structural parts simultaneously with a minimum of instrumentation only 3 weldable high temperature strain gauges were employed. These strain gauges were especially prepared and bent in such a way as to form a bridge between the inner wrapper and a fuel pin top and spot-welded to both the wrapper and the fuel pin. Although this arrangement seems to be a rather unusual one, the simultaneous-measurement of bundle, wrapper and pin vibrations was possible and periodic flow fluctuations were also detected. The presented results are only relative due to calibration difficulties with these deformed strain gauges which were first used during this test. It is, however, believed that this arrangement, in connection with the proposed anlytical approach, leads to a simple and technical representation of the vibrational behavior of core elements during sodium tests. Detailed information needed for check and calibration of computer codes are however displayed by the respective power spectral density functions

  15. dDYRK2 and Minibrain interact with the chromatin remodelling factors SNR1 and TRX.

    Science.gov (United States)

    Kinstrie, Ross; Lochhead, Pamela A; Sibbet, Gary; Morrice, Nick; Cleghon, Vaughn

    2006-08-15

    The DYRKs (dual specificity tyrosine phosphorylation-regulated kinases) are a conserved family of protein kinases that autophosphorylate a tyrosine residue in their activation loop by an intra-molecular mechanism and phosphorylate exogenous substrates on serine/threonine residues. Little is known about the identity of true substrates for DYRK family members and their binding partners. To address this question, we used full-length dDYRK2 (Drosophila DYRK2) as bait in a yeast two-hybrid screen of a Drosophila embryo cDNA library. Of 14 independent dDYRK2 interacting clones identified, three were derived from the chromatin remodelling factor, SNR1 (Snf5-related 1), and three from the essential chromatin component, TRX (trithorax). The association of dDYRK2 with SNR1 and TRX was confirmed by co-immunoprecipitation studies. Deletion analysis showed that the C-terminus of dDYRK2 modulated the interaction with SNR1 and TRX. DYRK family member MNB (Minibrain) was also found to co-precipitate with SNR1 and TRX, associations that did not require the C-terminus of the molecule. dDYRK2 and MNB were also found to phosphorylate SNR1 at Thr102 in vitro and in vivo. This phosphorylation required the highly conserved DH-box (DYRK homology box) of dDYRK2, whereas the DH-box was not essential for phosphorylation by MNB. This is the first instance of phosphorylation of SNR1 or any of its homologues and implicates the DYRK family of kinases with a role in chromatin remodelling.

  16. A Ramp Cosine Cepstrum Model for the Parameter Estimation of Autoregressive Systems at Low SNR

    Directory of Open Access Journals (Sweden)

    Zhu Wei-Ping

    2010-01-01

    Full Text Available A new cosine cepstrum model-based scheme is presented for the parameter estimation of a minimum-phase autoregressive (AR system under low levels of signal-to-noise ratio (SNR. A ramp cosine cepstrum (RCC model for the one-sided autocorrelation function (OSACF of an AR signal is first proposed by considering both white noise and periodic impulse-train excitations. Using the RCC model, a residue-based least-squares optimization technique that guarantees the stability of the system is then presented in order to estimate the AR parameters from noisy output observations. For the purpose of implementation, the discrete cosine transform, which can efficiently handle the phase unwrapping problem and offer computational advantages as compared to the discrete Fourier transform, is employed. From extensive experimentations on AR systems of different orders, it is shown that the proposed method is capable of estimating parameters accurately and consistently in comparison to some of the existing methods for the SNR levels as low as −5 dB. As a practical application of the proposed technique, simulation results are also provided for the identification of a human vocal tract system using noise-corrupted natural speech signals demonstrating a superior estimation performance in terms of the power spectral density of the synthesized speech signals.

  17. High-SNR spectrum measurement based on Hadamard encoding and sparse reconstruction

    Science.gov (United States)

    Wang, Zhaoxin; Yue, Jiang; Han, Jing; Li, Long; Jin, Yong; Gao, Yuan; Li, Baoming

    2017-12-01

    The denoising capabilities of the H-matrix and cyclic S-matrix based on the sparse reconstruction, employed in the Pixel of Focal Plane Coded Visible Spectrometer for spectrum measurement are investigated, where the spectrum is sparse in a known basis. In the measurement process, the digital micromirror device plays an important role, which implements the Hadamard coding. In contrast with Hadamard transform spectrometry, based on the shift invariability, this spectrometer may have the advantage of a high efficiency. Simulations and experiments show that the nonlinear solution with a sparse reconstruction has a better signal-to-noise ratio than the linear solution and the H-matrix outperforms the cyclic S-matrix whether the reconstruction method is nonlinear or linear.

  18. Lidar signal-to-noise ratio improvements: Considerations and techniques

    Science.gov (United States)

    Hassebo, Yasser Y.

    The primary objective of this study is to improve lidar signal-to-noise ratio (SNR) and hence extend attainable lidar ranges through reduction of the sky background noise (BGP), which dominates other sources of noise in daytime operations. This is particularly important for Raman lidar techniques where the Raman backscattered signal of interest is relatively weak compared with the elastic backscatter lidars. Two approaches for reduction of sky background noise are considered: (1) Improvements in lidar SNR by optimization of the design of the lidar receiver were examined by a series of simulations. This part of the research concentrated on biaxial lidar systems, where overlap between laser beam and receiver field of view (FOV) is an important aspect of noise considerations. The first optimized design evolved is a wedge shaped aperture. While this design has the virtue of greatly reducing background light, it is difficult to implement practically, requiring both changes in area and position with lidar range. A second more practical approach, which preserves some of the advantages of the wedge design, was also evolved. This uses a smaller area circular aperture optimally located in the image plane for desired ranges. Simulated numerical results for a biaxial lidar have shown that the best receiver parameters selection is one using a small circular aperture (field stop) with a small telescope focal length f, to ensure the minimum FOV that accepts all return signals over the entire lidar range while at the same time minimizing detected BGP and hence maximizing lidar SNR and attainable lidar ranges. The improvement in lidar SNR was up to 18%. (2) A polarization selection technique was implemented to reduce sky background signal for linearly polarized monostatic elastic backscatter lidar measurements. The technique takes advantage of naturally occurring polarization properties in scattered sky light, and then ensures that both the lidar transmitter and receiver track and

  19. SNR coolant system components

    International Nuclear Information System (INIS)

    De Haas Van Dorsser, A.H.; Mausbeck, H.

    1976-01-01

    The DEBENELUX prototype fast reactor power plant SNR 300 at Kalkar has a loop-type heat transfer system similar to that of the prototype LMFBR plants in the USA and Japan. There exist three 257 MW/sub th/ primary sodium loops, each with a hot leg centrifugal pump and three 85.6 MW/sub th/ intermediate heat exchangers in parallel. From there the heat is transferred to the steam generators via three secondary sodium loops with one cold leg sodium circulating pump in each. At a nominal reactor outlet temperature of 819 0 K and a turbine inlet power of 771 MW/sub th/ super heated steam of 166 bar and 733 0 K is produced, giving rise to a plant rating of 327 MW/sub e/ gross. The primary and secondary loops are described in detail

  20. Business sustainability performance measurement: Eco-ratio analysis

    Directory of Open Access Journals (Sweden)

    Collins C. Ngwakwe

    2016-12-01

    Full Text Available Eco-aware customers and stakeholders are demanding for a measurement that links environmental performance with other business operations. To bridge this seemingly measurement gap, this paper suggests ‘Eco-Ratio Analysis’ and proposes an approach for conducting eco-ratio analysis. It is argued that since accounting ratios function as a tool for evaluating corporate financial viability by management and investors, eco-ratio analysis should be brought to the fore to provide a succinct measurement about the linkage between environmental performance and conventional business performance. It is hoped that this suggestion will usher in a nuance debate and approach in the teaching, research and practice of environmental management and sustainability accounting

  1. Multifrequency radio observations of SNR J0536-6735 (N 59B with associated pulsar

    Directory of Open Access Journals (Sweden)

    Bozzetto L.M.

    2012-01-01

    Full Text Available We present a study of new Australian Telescope Compact Array (ATCA observations of supernova remnant, SNR J0536-6735. This remnant appears to follow a shell morphology with a diameter of D=36x29 pc (with 1 pc uncertainty in each direction. There is an embedded HII region on the northern limb of the remnant which made various analysis and measurements (such as flux density, spectral index and polarisation difficult. The radio-continuum emission followed the same structure as the optical emission, allowing for extent and flux density estimates at 20 cm. We estimate the surface brightness at 1 GHz of 2.55x10−21 Wm−2 Hz−1 sr−1 for the SNR. Also, we detect a distinctive radio-continuum point source which confirms the previous suggestion of this remnant being associated with pulsar wind nebula (PWN. The tail of this remnant is not seen in the radio-continuum images and is only seen in the optical and X-ray images.

  2. Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arrays.

    Science.gov (United States)

    Pohmann, Rolf; Speck, Oliver; Scheffler, Klaus

    2016-02-01

    Relaxation times, transmit homogeneity, signal-to-noise ratio (SNR) and parallel imaging g-factor were determined in the human brain at 3T, 7T, and 9.4T, using standard, tight-fitting coil arrays. The same human subjects were scanned at all three field strengths, using identical sequence parameters and similar 31- or 32-channel receive coil arrays. The SNR of three-dimensional (3D) gradient echo images was determined using a multiple replica approach and corrected with measured flip angle and T2 (*) distributions and the T1 of white matter to obtain the intrinsic SNR. The g-factor maps were derived from 3D gradient echo images with several GRAPPA accelerations. As expected, T1 values increased, T2 (*) decreased and the B1 -homogeneity deteriorated with increasing field. The SNR showed a distinctly supralinear increase with field strength by a factor of 3.10 ± 0.20 from 3T to 7T, and 1.76 ± 0.13 from 7T to 9.4T over the entire cerebrum. The g-factors did not show the expected decrease, indicating a dominating role of coil design. In standard experimental conditions, SNR increased supralinearly with field strength (SNR ∼ B0 (1.65) ). To take full advantage of this gain, the deteriorating B1 -homogeneity and the decreasing T2 (*) have to be overcome. © 2015 Wiley Periodicals, Inc.

  3. Future development LMFBR-steam generators SNR2

    International Nuclear Information System (INIS)

    Essebaggers, J.; Pors, J.G.

    1975-01-01

    The development work for steam generators for large LMFBR plants by Neratoom will be reviewed consisting of: 1. Development engineering information. 2. Concept select studies followed by conceptual designs of selected models. 3. Development manufacturing techniques. 4. Detail design of a prototype unit. 5. Testing of sub-constructions for prototype steam generators. In this presentation item 1 and 2 above will be high lighted, identifying the development work for the SNR-2 steam generators on short term basis. (author)

  4. Highly accurate adaptive TOF determination method for ultrasonic thickness measurement

    Science.gov (United States)

    Zhou, Lianjie; Liu, Haibo; Lian, Meng; Ying, Yangwei; Li, Te; Wang, Yongqing

    2018-04-01

    Determining the time of flight (TOF) is very critical for precise ultrasonic thickness measurement. However, the relatively low signal-to-noise ratio (SNR) of the received signals would induce significant TOF determination errors. In this paper, an adaptive time delay estimation method has been developed to improve the TOF determination’s accuracy. An improved variable step size adaptive algorithm with comprehensive step size control function is proposed. Meanwhile, a cubic spline fitting approach is also employed to alleviate the restriction of finite sampling interval. Simulation experiments under different SNR conditions were conducted for performance analysis. Simulation results manifested the performance advantage of proposed TOF determination method over existing TOF determination methods. When comparing with the conventional fixed step size, and Kwong and Aboulnasr algorithms, the steady state mean square deviation of the proposed algorithm was generally lower, which makes the proposed algorithm more suitable for TOF determination. Further, ultrasonic thickness measurement experiments were performed on aluminum alloy plates with various thicknesses. They indicated that the proposed TOF determination method was more robust even under low SNR conditions, and the ultrasonic thickness measurement accuracy could be significantly improved.

  5. Risk oriented analysis of the SNR-300

    International Nuclear Information System (INIS)

    Koeberlein, K.

    1982-01-01

    The Fact Finding Committee on 'Future Nuclear Power Policy' established by the 8th German Federal Parliament in its report of June 1980 among other items published the recommendation to commission a 'risk oriented analysis' of the SNR-300 in order to enable a pragmatic comparison to be made of the safety of the German prototype fast breeder reactor and a modern light water reactor (a Biblis B PWR). The Federal Minister for Research and Technology in August 1981 officially commissioned the Gesellschaft fuer Reaktorsicherheit (GRS) to conduct the study. Following a recommendation by the Fact Finding Committee, additional studies were performed also by a group of opponents of the breeder reactor. On the instigation of the group of opponents the delivery date of the study was altered several times and finally set at April 30, 1982. GRS submitted its report by this deadline. However, a joint report by the two groups could not be compiled, as had been requested by the client, because the contributions of the opponents were not made available until mid-May 1982 and then only as an 'interim report'. In summary, the GRS study indicates that the frequency and severity of major accidents is lower for the SNR-300 at the Kalkar site than for a PWR as covered in the German Nuclear Power Plant Risk Study. (orig.) [de

  6. Relevancies of multiple-interaction events and signal-to-noise ratio for Anger-logic based PET detector designs

    Science.gov (United States)

    Peng, Hao

    2015-10-01

    A fundamental challenge for PET block detector designs is to deploy finer crystal elements while limiting the number of readout channels. The standard Anger-logic scheme including light sharing (an 8 by 8 crystal array coupled to a 2×2 photodetector array with an optical diffuser, multiplexing ratio: 16:1) has been widely used to address such a challenge. Our work proposes a generalized model to study the impacts of two critical parameters on spatial resolution performance of a PET block detector: multiple interaction events and signal-to-noise ratio (SNR). The study consists of the following three parts: (1) studying light output profile and multiple interactions of 511 keV photons within crystal arrays of different crystal widths (from 4 mm down to 1 mm, constant height: 20 mm); (2) applying the Anger-logic positioning algorithm to investigate positioning/decoding uncertainties (i.e., "block effect") in terms of peak-to-valley ratio (PVR), with light sharing, multiple interactions and photodetector SNR taken into account; and (3) studying the dependency of spatial resolution on SNR in the context of modulation transfer function (MTF). The proposed model can be used to guide the development and evaluation of a standard Anger-logic based PET block detector including: (1) selecting/optimizing the configuration of crystal elements for a given photodetector SNR; and (2) predicting to what extent additional electronic multiplexing may be implemented to further reduce the number of readout channels.

  7. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boss, Andreas, E-mail: andreas.boss@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Piccirelli, Marco [Institute of Neuroradiology, University Hospital of Zurich (Switzerland); Reiner, Caecilia S. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland)

    2016-11-15

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  8. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    International Nuclear Information System (INIS)

    Boss, Andreas; Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C.; Piccirelli, Marco; Reiner, Caecilia S.

    2016-01-01

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  9. Relationship of signal-to-noise ratio with acquisition parameters in MRI for a given contrast

    International Nuclear Information System (INIS)

    Bittoun, J.; Leroy-Willig, A.; Idy, I.; Halimi, P.; Syrota, A.; Desgrez, A.; Saint-Jalmes, H.

    1987-01-01

    The signal-to-noise ratio (SNR) is certainly the most important characteristic of medical images, since the spatial resolution and the visualization of contrast are dependent on its value. On the other hand, modifying an acquisition variable in magnetic resonance imaging, in order to improve spatial resolution for example, may induce a SNR loss and finally alter the image quality. We have studied a theoretical relation between SNR and 2DFT method acquisition variables with the exception of parameters such as TR, TE and TI; these parameters are determined by the desired contrast in order to confirm a diagnosis. According to this relation SNR is proportional to each dimension of the slice, and to the square root of the number of averaged signals; it is inversely proportional to the number of frequency points and to the square root of the number of phase points. This relation was experimentally verified with phantoms and on an MR system at 1.5 T. It was then plotted as a multiple-entry graph on which operators at the console can read the number of averaged signals necessary to compensate SNR loss induced by a modification of other parameters [fr

  10. Numerical simulation and measurements of acoustic transmissions from Heard Island to the equatorial Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    PrasannaKumar, S.; Navelkar, G.S.; Murty, T.V.R.; Somayajulu, Y.K.; Saran, A.K.; Murty, C.S.

    of the Sub Tropical Convergence. Measured acoustic signals, received at the Indian listening station has a signal to noise ratio (SNR) of 20 dB on an average and confirmed their detectability over distances as far as 7000 km. The phase stability...

  11. Blood flow measurement of transverse sinuses by using MR: a phantom study of its influence factors

    International Nuclear Information System (INIS)

    Gao Gejun; Feng Xiaoyuan; Li Yuan; Geng Daoying; Yao Zhengyu

    2003-01-01

    Objective: (1) To determine the relationship between the MR signal intensity and the actual flow velocity under steady flow condition. (2) to analyze the influence produced by the angle (θ) between the flow direction and the velocity-encoded gradient direction, and flip angle as well as section thickness on the velocity measurement under oblique flow condition. (3) to develop a suitable protocol for using this method to measure volumetric flow rate in the transverse sinus system. Methods: Flow phantom, which simulated blood-flow conditions in the transverse sinus system, consisted of a fluid-filled cylinder and a bent tube with a 3.4 mm internal diameter. A 1.5 T superconductive MR imager and VIGRE sequence were used for these studies. A suitable protocol was based on consideration of the effects of (1) the accuracy of velocity and transverse area measurement of flow, and (2) signal-to-noise ratio (SNR). Results: (1) Signal intensity (y) determined by MR and the actual flow velocity (x) showed straight-line correlation, y=68.914x + 357.206, R 2 =0.998. (2) As the angle (θ) increased, the transverse area of the signal determined by MR also increased, but the value of flow velocity decreased. (3) As the flip angle increased, the SNR varied from 5.7 to 11.2. The maximum SNR was obtained with 30 degree flip angle. (4) As the section thickness increased, the SNR and the transverse area of the signal determined by MR slightly increased. Conclusions: Phase-contrast MR imaging is a practical method for measuring volumetric flow rates. The angle (θ influenced the accuracy of flow velocity and the measurement of transverse area of flow whereas the flip angle and the section thickness substantially influenced the signal-to-noise ratio and the transverse area of flow

  12. Study of the accidental risk of the German fast breeder prototype reactor SNR-300

    International Nuclear Information System (INIS)

    Koeberlein, K.

    1983-01-01

    A fact-finding committee of the German Federal Parliament in July 1980 recommended to perform a 'risk-oriented study' of the SNR-300, the German 300 MWe fast breeder prototype reactor being under construction at Kalkar. The main aim of this study was to allow a comparative safety evaluation between the SNR-300 and a modern PWR, thus to prepare a basis for a political decision on the SNR-300. Methods and main results of the study are presented in this paper. In the first step of the study six groups of accidents have been identified which may initiate core destruction. By reliability analyses, expected frequency of each group has been estimated. Conditional probabilities for conceivable reactor tank failure modes have been analysed. Tank failure after core destruction leads to release of energy and radioactive material into the containment system. Such accident sequences have been pursued further. Based on a number of core destruction initiators and tank failure modes and various combinations of success and failure states of the containment systems, detailed calculations of different containment scenarious were carried out. From the results of the plant systems analysis, five release categories have been defined. Possible effects of external events and releases of radioactivity from the spent fuel storage pool have also been analysed. In order to quantify the degree of uncertainty of the calculated frequencies, subjective probability distributions of fixed, but inaccurately known quantities have been propagated through the calculations. Using the release categories as input, accident consequences were calculated for the site Kalkar. Though the uncertainty bandwidths for the accident frequencies estimated in the SNR-300 analysis are much wider than for the PWR, the analysis indicates that frequencies of severe accidents, and consequences, are smaller for the SNR-300 than for the PWR as analysed in the 'German Risk Study'. (orig.)

  13. Intelligibility for Binaural Speech with Discarded Low-SNR Speech Components.

    Science.gov (United States)

    Schoenmaker, Esther; van de Par, Steven

    2016-01-01

    Speech intelligibility in multitalker settings improves when the target speaker is spatially separated from the interfering speakers. A factor that may contribute to this improvement is the improved detectability of target-speech components due to binaural interaction in analogy to the Binaural Masking Level Difference (BMLD). This would allow listeners to hear target speech components within specific time-frequency intervals that have a negative SNR, similar to the improvement in the detectability of a tone in noise when these contain disparate interaural difference cues. To investigate whether these negative-SNR target-speech components indeed contribute to speech intelligibility, a stimulus manipulation was performed where all target components were removed when local SNRs were smaller than a certain criterion value. It can be expected that for sufficiently high criterion values target speech components will be removed that do contribute to speech intelligibility. For spatially separated speakers, assuming that a BMLD-like detection advantage contributes to intelligibility, degradation in intelligibility is expected already at criterion values below 0 dB SNR. However, for collocated speakers it is expected that higher criterion values can be applied without impairing speech intelligibility. Results show that degradation of intelligibility for separated speakers is only seen for criterion values of 0 dB and above, indicating a negligible contribution of a BMLD-like detection advantage in multitalker settings. These results show that the spatial benefit is related to a spatial separation of speech components at positive local SNRs rather than to a BMLD-like detection improvement for speech components at negative local SNRs.

  14. On the origin of the system PSR B 1757-24/SNR G 5.4-1.2

    Science.gov (United States)

    Gvaramadze, V. V.

    2004-03-01

    A scenario for the origin of the system PSR B 1757-24/supernova remnant (SNR) G 5.4-1.2 is proposed. It is suggested that both objects are the remnants of a supernova (SN) that exploded within a pre-existing bubble blown-up by a runaway massive star (the SN progenitor) during the final (Wolf-Rayet) phase of its evolution. This suggestion implies that (a) the SN blast centre was significantly offset from the geometric centre of the wind-blown bubble (i.e. from the centre of the future SNR), (b) the bubble was surrounded by a massive wind-driven shell, and (c) the SN blast wave was drastically decelerated by the interaction with the shell. Therefore, one can understand how the relatively young and low-velocity pulsar PSR B 1757-24 was able to escape from the associated SNR G 5.4-1.2 and why the inferred vector of pulsar transverse velocity does not point away from the geometric centre of the SNR. A possible origin of the radio source G 5.27-0.9 (located between PSR B 1757-24 and the SNR G 5.4-1.2) is proposed. It is suggested that G 5.27-0.9 is a lobe of a low Mach number (≃1.7) jet of gas outflowing from the interior of G 5.4-1.2 through the hole bored in the SNR's shell by the escaping pulsar. It is also suggested that the non-thermal emission of the comet-shaped pulsar wind nebula originates in the vicinity of the termination shock and in the cylindric region of subsonically moving shocked pulsar wind. The role of magnetized wind-driven shells (swept-up during the Wolf-Rayet phase from the ambient interstellar medium with the regular magnetic field) in formation of elongated axisymmetric SNRs is discussed.

  15. Large signal-to-noise ratio quantification in MLE for ARARMAX models

    Science.gov (United States)

    Zou, Yiqun; Tang, Xiafei

    2014-06-01

    It has been shown that closed-loop linear system identification by indirect method can be generally transferred to open-loop ARARMAX (AutoRegressive AutoRegressive Moving Average with eXogenous input) estimation. For such models, the gradient-related optimisation with large enough signal-to-noise ratio (SNR) can avoid the potential local convergence in maximum likelihood estimation. To ease the application of this condition, the threshold SNR needs to be quantified. In this paper, we build the amplitude coefficient which is an equivalence to the SNR and prove the finiteness of the threshold amplitude coefficient within the stability region. The quantification of threshold is achieved by the minimisation of an elaborately designed multi-variable cost function which unifies all the restrictions on the amplitude coefficient. The corresponding algorithm based on two sets of physically realisable system input-output data details the minimisation and also points out how to use the gradient-related method to estimate ARARMAX parameters when local minimum is present as the SNR is small. Then, the algorithm is tested on a theoretical AutoRegressive Moving Average with eXogenous input model for the derivation of the threshold and a gas turbine engine real system for model identification, respectively. Finally, the graphical validation of threshold on a two-dimensional plot is discussed.

  16. Correlation between the signal-to-noise ratio improvement factor (KSNR) and clinical image quality for chest imaging with a computed radiography system

    International Nuclear Information System (INIS)

    Moore, C S; Wood, T J; Saunderson, J R; Beavis, A W

    2015-01-01

    This work assessed the appropriateness of the signal-to-noise ratio improvement factor (K SNR ) as a metric for the optimisation of computed radiography (CR) of the chest. The results of a previous study in which four experienced image evaluators graded computer simulated chest images using a visual grading analysis scoring (VGAS) scheme to quantify the benefit of using an anti-scatter grid were used for the clinical image quality measurement (number of simulated patients  =  80). The K SNR was used to calculate the improvement in physical image quality measured in a physical chest phantom. K SNR correlation with VGAS was assessed as a function of chest region (lung, spine and diaphragm/retrodiaphragm), and as a function of x-ray tube voltage in a given chest region. The correlation of the latter was determined by the Pearson correlation coefficient. VGAS and K SNR image quality metrics demonstrated no correlation in the lung region but did show correlation in the spine and diaphragm/retrodiaphragmatic regions. However, there was no correlation as a function of tube voltage in any region; a Pearson correlation coefficient (R) of  −0.93 (p  =  0.015) was found for lung, a coefficient (R) of  −0.95 (p  =  0.46) was found for spine, and a coefficient (R) of  −0.85 (p  =  0.015) was found for diaphragm. All demonstrate strong negative correlations indicating conflicting results, i.e. K SNR increases with tube voltage but VGAS decreases. Medical physicists should use the K SNR metric with caution when assessing any potential improvement in clinical chest image quality when introducing an anti-scatter grid for CR imaging, especially in the lung region. This metric may also be a limited descriptor of clinical chest image quality as a function of tube voltage when a grid is used routinely. (paper)

  17. The Association of PSR B1757-24 and the SNR G5.4-1.2

    Science.gov (United States)

    Gvaramadze, V. V.

    The association of PSR B1757-24 and the supernova remnant (SNR) G5.4-1.2 was recently questioned by Thorsett et al. (2002) on the basis of proper motion measurements of the pulsar and the "incorrect" orientation of the vector of pulsar transverse velocity (inferred from the orientation of the cometary-shaped pulsar wind nebula). We show, however, that the association could be real if both objects are the remnants of an off-centered cavity supernova explosion.

  18. The SNR 300 fast breeder in the ups and downs of its history

    International Nuclear Information System (INIS)

    Marth, W.

    1994-12-01

    The Fast Breeder Project was founded in Karlsruhe in 1960. After an initial period of fundamental research, industry assumed responsibility for designing the SNR 300. Construction of the Kalkar Nuclear Power Station was hampered by a variety of political influences, but finally completed in 1985. As a consequence of the North Rhine-Westphalian party-in-government's opting out of nuclear power, no startup permit was issued for the SNR 300. Consequently, the Kalkar Nuclear Power Station project was discontinued for political reasons in March 1991. The report is the English translation of KFK--4466. (orig./HP) [de

  19. Study of signal-to-noise ratio in digital mammography

    Science.gov (United States)

    Kato, Yuri; Fujita, Naotoshi; Kodera, Yoshie

    2009-02-01

    Mammography techniques have recently advanced from those using analog systems (the screen-film system) to those using digital systems; for example, computed radiography (CR) and flat-panel detectors (FPDs) are nowadays used in mammography. Further, phase contrast mammography (PCM)-a digital technique by which images with a magnification of 1.75× can be obtained-is now available in the market. We studied the effect of the air gap in PCM and evaluated the effectiveness of an antiscatter x-ray grid in conventional mammography (CM) by measuring the scatter fraction ratio (SFR) and relative signal-to-noise ratio (rSNR) and comparing them between PCM and the digital CM. The results indicated that the SFRs for the CM images obtained with a grid were the lowest and that these ratios were almost the same as those for the PCM images. In contrast, the rSNRs for the PCM images were the highest, which means that the scattering of x-rays was sufficiently reduced by the air gap without the loss of primary x-rays.

  20. Ratio method of measuring W boson mass

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Feng [Stony Brook Univ., NY (United States)

    2010-08-01

    This dissertation describes an alternative method of measuring the W boson mass in DØ experiment. Instead of extracting MW from the fitting of W → ev fast Monte Carlo simulations to W → ev data as in the standard method, we make the direct fit of transverse mass between W → ev data and Z → ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (MW/MZ). Given the precisely measured Z boson mass, W mass is directly fitted from W → ev and Z → ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb-1 DØ Run IIa dataset, ratio method gives MW = 80435 ± 43(stat) ± 26(sys) MeV.

  1. The possibilities of application of experimental Kfk results from BR2 on SNR designs

    International Nuclear Information System (INIS)

    Karsten, G.; Elbel, K.; Dienst, W.; Schaefer, L.

    1978-01-01

    A review is given of the relevant results of the technological application for the SNR300 reactor, since the BR2 reactor has been used as a test facility for the material development. Special emphasis has been laid on the fuel pin behavior under the aspect of chemical and mechanical fuel-clad interaction and on the specification of the cladding in terms of high temperature mechanical behavior in the SNR 300 reactor. A systematic analysis of urgent research topics in BR2 test facility reactor is presented. (A.F.)

  2. Small leak detection requirements for SNR-300 steam generator operation

    International Nuclear Information System (INIS)

    Dumm, K.

    1975-01-01

    The leak detection philosophy of the SNR-300 steam generators is described. Due to operational demands small leaks have already to be detectable at a stage where secondary tube damage has not yet occurred. The requirements on a leak detection instrument are developed and the instrument itself is described. (author)

  3. Small leak detection requirements for SNR-300 steam generator operation

    Energy Technology Data Exchange (ETDEWEB)

    Dumm, K

    1975-07-01

    The leak detection philosophy of the SNR-300 steam generators is described. Due to operational demands small leaks have already to be detectable at a stage where secondary tube damage has not yet occurred. The requirements on a leak detection instrument are developed and the instrument itself is described. (author)

  4. Quality assurance in MRI breast screening: comparing signal-to-noise ratio in dynamic contrast-enhanced imaging protocols

    Science.gov (United States)

    Kousi, Evanthia; Borri, Marco; Dean, Jamie; Panek, Rafal; Scurr, Erica; Leach, Martin O.; Schmidt, Maria A.

    2016-01-01

    MRI has been extensively used in breast cancer staging, management and high risk screening. Detection sensitivity is paramount in breast screening, but variations of signal-to-noise ratio (SNR) as a function of position are often overlooked. We propose and demonstrate practical methods to assess spatial SNR variations in dynamic contrast-enhanced (DCE) breast examinations and apply those methods to different protocols and systems. Four different protocols in three different MRI systems (1.5 and 3.0 T) with receiver coils of different design were employed on oil-filled test objects with and without uniformity filters. Twenty 3D datasets were acquired with each protocol; each dataset was acquired in under 60 s, thus complying with current breast DCE guidelines. In addition to the standard SNR calculated on a pixel-by-pixel basis, we propose other regional indices considering the mean and standard deviation of the signal over a small sub-region centred on each pixel. These regional indices include effects of the spatial variation of coil sensitivity and other structured artefacts. The proposed regional SNR indices demonstrate spatial variations in SNR as well as the presence of artefacts and sensitivity variations, which are otherwise difficult to quantify and might be overlooked in a clinical setting. Spatial variations in SNR depend on protocol choice and hardware characteristics. The use of uniformity filters was shown to lead to a rise of SNR values, altering the noise distribution. Correlation between noise in adjacent pixels was associated with data truncation along the phase encoding direction. Methods to characterise spatial SNR variations using regional information were demonstrated, with implications for quality assurance in breast screening and multi-centre trials.

  5. Signal-to-noise ratio of bilateral nonimaging transcranial Doppler recordings of the middle cerebral artery is not affected by age and sex.

    Science.gov (United States)

    Katsogridakis, Emmanuel; Dineen, Nicky E; Brodie, Fiona G; Robinson, Thompson G; Panerai, Ronney B

    2011-04-01

    Differences between transcranial Doppler ultrasonography (TCD) recordings of symmetrical vessels can show true physiologic differences, but can also be caused by measurement error and other sources of noise. The aim of this project was to assess the influence of noise on estimates of dynamic cerebral autoregulation (dCA), and of age, sex and breathing manoeuvres on the signal-to-noise ratio (SNR). Cerebral blood flow (CBF) was monitored in 30 young (60 years) during baseline conditions, breath-holding and hyperventilation. Noise was defined as the difference between beat-to-beat values of the two mean CBF velocity (CBFV) signals. Magnitude squared coherence estimates of noise vs. ABP and ABP vs. CBFV were obtained and averaged. A similar approach was adopted for the CBFV step response. The effect of age and breathing manoeuvre on the SNR was assessed using a two-way analysis of variance (ANOVA), whilst the effect of sex was investigated using a Student's t test. No significant differences were observed in SNR (baseline 6.07 ± 3.07 dB and 7.33 ± 3.84 dB, breath-hold: 13.53 ± 3.93 dB and 14.64 ± 4.52 dB, and hyperventilation: 14.69 ± 4.04 dB and 14.84 ± 4.05 dB) estimates between young and old groups, respectively. The use of breathing manoeuvres significantly improved the SNR (p < 10(-4)) without a significant difference between manoeuvres. Sex does not appear to have an effect on SNR (p = 0.365). Coherence estimates were not influenced by the SNR, but significant differences were found in the amplitude of the CBFV step response. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Measuring Poisson Ratios at Low Temperatures

    Science.gov (United States)

    Boozon, R. S.; Shepic, J. A.

    1987-01-01

    Simple extensometer ring measures bulges of specimens in compression. New method of measuring Poisson's ratio used on brittle ceramic materials at cryogenic temperatures. Extensometer ring encircles cylindrical specimen. Four strain gauges connected in fully active Wheatstone bridge self-temperature-compensating. Used at temperatures as low as liquid helium.

  7. Suzaku observation of TeV SNR RX J1713.7-3946

    International Nuclear Information System (INIS)

    Takahashi, Tadayuki; Tanaka, Takaaki; Uchiyama, Yasunobu

    2007-01-01

    We report on results from Suzaku broadband X-ray observations of the Galactic supernova remnant (SNR) RX J1713.7-3946 with an energy coverage of 0.4-40 keV. With a sensitive hard X-ray measurement from the HXD PIN on board Suzaku, we determine the hard X-ray spectrum in the 12-40 keV range to be described by a power law with photon index Γ=3.2±0.2, significantly steeper than the soft X-ray index of Γ=2.4±0.05 measured previously with ASCA and other missions. We find that a simple power law fails to describe the full spectral range of 0.4-40 keV and instead a cutoff power law with hard index Γ=1.96±0.05 and high energy cutoff ε c =9±1 keV provides an excellent fit over the full bandpass. (author)

  8. The influence of the maximal value and peak enhancement value of arterial and venous enhancement curve on CT perfusion parameters and signal-to-noise ratio

    International Nuclear Information System (INIS)

    Ju Haiyue; Gao Sijia; Xu Ke; Wang Qiang

    2007-01-01

    Objective: To explore the influence of the maximal value and peak enhancement value of arterial and venous enhancement curve on CT perfusion parameters and signal-to-noise ratio (SNR). Methods: Seventeen patients underwent brain CT perfusion scanning. All row data were analyzed with perfusion software for 6 times, and get different arterial and venous enhancement curves for each patient. The maximal values and peak enhancement values of each arterial and venous enhancement curves, as well as mean perfusion parameters including cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), permeability surface area product (PS), and their standard deviations (SD) in homolateral white and gray matter were measured and recorded. SNR was calculated by dividing the mean perfusion parameter value by its SD. Pearson correlation analysis and two-tailed paired Student t test were used for statistics. Results: The maximal values and peak enhancement values of arterial and venous curves were correlated with mean SNR CBF , SNR CBV and SNR MTT in both white matter and gray matters (r value range: 0.332-0.922, P PS in white matter(r=0.256, P PS (in both white matter and gray matters) and arterial peak enhancement values, the maximal values and venous peak enhancement values, or between SNR PS (in gray matter) and the maximal values of venous curve(r value range: -0.058-0.210, P>0.05). (2) Mean CBF, CBV and PS values in the group with low venous peak enhancement values were significantly different from the group with high venous peak enhancement values in both white and gray matters (t value range: 3.830-5.337, P 0.05). Conclusions: The mean perfusion parameters and SNR are influenced by the maximal values and peak enhancement values of the arterial and venous curves. Peak enhancement of arterial and venous curves should be adjusted to higher level to make parameter values more reliable and increase the SNR. (authors)

  9. Quasi Cyclic Low Density Parity Check Code for High SNR Data Transfer

    Directory of Open Access Journals (Sweden)

    M. R. Islam

    2010-06-01

    Full Text Available An improved Quasi Cyclic Low Density Parity Check code (QC-LDPC is proposed to reduce the complexity of the Low Density Parity Check code (LDPC while obtaining the similar performance. The proposed QC-LDPC presents an improved construction at high SNR with circulant sub-matrices. The proposed construction yields a performance gain of about 1 dB at a 0.0003 bit error rate (BER and it is tested on 4 different decoding algorithms. Proposed QC-LDPC is compared with the existing QC-LDPC and the simulation results show that the proposed approach outperforms the existing one at high SNR. Simulations are also performed varying the number of horizontal sub matrices and the results show that the parity check matrix with smaller horizontal concatenation shows better performance.

  10. Inelastic analysis of SNR-300 piping

    International Nuclear Information System (INIS)

    Huebel, H.; Di Luna, L.J.; Moy, G.

    1983-01-01

    This paper investigates plasticity, creep, and elastic follow-up effects on a full size hot primary piping system of the German fast breeder reactor prototype, the SNR-300. A large model (327 elements, 419 nodes) of straight pipe, special elbow and hanger elements of the general purpose finite element program, MARC-CDC, is used to predict piping behavior for a heat-up, sodium loading-unloading-reloading cycle and other significant operating conditions. Included in this work are many time-dependent solution increments for a 5,000 hour creep period. Creep strains and relaxed stress results, after 5,000 hours, for the complete model are used with uniaxial and biaxial models and results to extrapolate conclusions for a 100,000 hour operating life. (author)

  11. Inelastic analysis of SNR-300 piping

    Energy Technology Data Exchange (ETDEWEB)

    Huebel, H [INTERATOM, Bergisch Gladbach (Germany); Di Luna, L J; Moy, G [Teledyne Engineering Services, Waltham, MA (United States)

    1983-05-01

    This paper investigates plasticity, creep, and elastic follow-up effects on a full size hot primary piping system of the German fast breeder reactor prototype, the SNR-300. A large model (327 elements, 419 nodes) of straight pipe, special elbow and hanger elements of the general purpose finite element program, MARC-CDC, is used to predict piping behavior for a heat-up, sodium loading-unloading-reloading cycle and other significant operating conditions. Included in this work are many time-dependent solution increments for a 5,000 hour creep period. Creep strains and relaxed stress results, after 5,000 hours, for the complete model are used with uniaxial and biaxial models and results to extrapolate conclusions for a 100,000 hour operating life. (author)

  12. Low SNR capacity for MIMO Rician and Rayleigh-product fading channels with single co-channel interferer and noise

    KAUST Repository

    Zhong, Caijun

    2010-09-01

    This paper studies the ergodic capacity of multiple-input multiple-output (MIMO) systems with a single co-channel interferer in the low signal-to-noise-ratio (SNR) regime. Two MIMO models namely Rician and Rayleigh-product channels are investigated. Exact analytical expressions for the minimum energy per information bit, {Eb/N0min, and wideband slope, S0, are derived for both channels. Our results show that the minimum energy per information bit is the same for both channels while their wideband slopes differ significantly. Further, the impact of the numbers of transmit and receive antennas, the Rician K factor, the channel mean matrix and the interference-to-noise-ratio (INR) on the capacity, is addressed. Results indicate that interference degrades the capacity by increasing the required minimum energy per information bit and reducing the wideband slope. Simulation results validate our analytical results. © 2010 IEEE.

  13. Uranium isotope ratio measurements in field settings

    International Nuclear Information System (INIS)

    Shaw, R.W.; Barshick, C.M.; Young, J.P.; Ramsey, J.M.

    1997-01-01

    The authors have developed a technique for uranium isotope ratio measurements of powder samples in field settings. Such a method will be invaluable for environmental studies, radioactive waste operations, and decommissioning and decontamination operations. Immediate field data can help guide an ongoing sampling campaign. The measurement encompasses glow discharge sputtering from pressed sample hollow cathodes, high resolution laser spectroscopy using conveniently tunable diode lasers, and optogalvanic detection. At 10% 235 U enrichment and above, the measurement precision for 235 U/( 235 U+ 238 U) isotope ratios was ±3%; it declined to ±15% for 0.3% (i.e., depleted) samples. A prototype instrument was constructed and is described

  14. GMTI Direction of Arrival Measurements from Multiple Phase Centers.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bickel, Douglas L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    Ground Moving Target Indicator (GMTI) radar attempts to detect and locate targets with unknown motion. Very slow-moving targets are difficult to locate in the presence of surrounding clutter. This necessitates multiple antenna phase centers (or equivalent) to offer independent Direction of Arrival (DOA) measurements. DOA accuracy and precision generally remains dependent on target Signal-to-Noise Ratio (SNR), Clutter-toNoise Ratio (CNR), scene topography, interfering signals, and a number of antenna parameters. This is true even for adaptive techniques like Space-Time-AdaptiveProcessing (STAP) algorithms.

  15. Corrosion and deposition behaviour of 60Co and 54Mn in the SNR mockup loop for the primary sodium system

    International Nuclear Information System (INIS)

    Menken, G.; Reichel, H.

    1976-01-01

    The SNR corrosion mockup loop, simulating the SNR primary system is described. The influence of hydraulic conditions and temperature on the deposition behaviour is studied. γ-spectroscopy measurements at the pipe-work and removable samples allowed to determine the distribution of radioactive corrosion products in the loop and by-pass system. The release rate of Mn 54 could be reduced by a factor of 3 by decreasing the cold trap temperature from 165 0 C to 105 0 C while the Co 60 release rate could be reduced by a factor of 14, respectively. High temperature loop sections (873K) representing 13% of the loop surface absorbed 50-60% of the released Co 60 and only 8 - 18% of the Mn 54. The cold trap absorbed not more than 1% of the Co 60 and 10% of the Mn 54 inventory. (author)

  16. Reproducibility of isotope ratio measurements

    International Nuclear Information System (INIS)

    Elmore, D.

    1981-01-01

    The use of an accelerator as part of a mass spectrometer has improved the sensitivity for measuring low levels of long-lived radionuclides by several orders of magnitude. However, the complexity of a large tandem accelerator and beam transport system has made it difficult to match the precision of low energy mass spectrometry. Although uncertainties for accelerator measured isotope ratios as low as 1% have been obtained under favorable conditions, most errors quoted in the literature for natural samples are in the 5 to 20% range. These errors are dominated by statistics and generally the reproducibility is unknown since the samples are only measured once

  17. Intrinsic low pass filtering improves signal-to-noise ratio in critical-point flexure biosensors

    International Nuclear Information System (INIS)

    Jain, Ankit; Alam, Muhammad Ashraful

    2014-01-01

    A flexure biosensor consists of a suspended beam and a fixed bottom electrode. The adsorption of the target biomolecules on the beam changes its stiffness and results in change of beam's deflection. It is now well established that the sensitivity of sensor is maximized close to the pull-in instability point, where effective stiffness of the beam vanishes. The question: “Do the signal-to-noise ratio (SNR) and the limit-of-detection (LOD) also improve close to the instability point?”, however remains unanswered. In this article, we systematically analyze the noise response to evaluate SNR and establish LOD of critical-point flexure sensors. We find that a flexure sensor acts like an effective low pass filter close to the instability point due to its relatively small resonance frequency, and rejects high frequency noise, leading to improved SNR and LOD. We believe that our conclusions should establish the uniqueness and the technological relevance of critical-point biosensors.

  18. Experimental and theoretical investigations on safety of the SNR - straight-tube design steam generator with sodium-water reactions

    International Nuclear Information System (INIS)

    Dumm, K.; Sauermann, F.; Schnitker, W.; Welter, A.

    A number of large sodium-water reaction tests has been performed in a steam generator model in order to verify the layout criteria of the SNR straight-tube design steam generators under accident conditions. The experimental setup is described. The test results and their applicability to the SNR steam generators are given and discussed. (U.S.)

  19. How the signal‐to‐noise ratio influences hyperpolarized 13C dynamic MRS data fitting and parameter estimation

    DEFF Research Database (Denmark)

    Santarelli, Maria Filomena; Positano, Vincenzo; Giovannetti, Giulio

    2012-01-01

    signals with low signal‐to‐noise ratio (SNR). The relationship between SNR and the precision of quantitative analysis for the evaluation of the in vivo kinetic behavior of metabolites is unknown. In this article, this topic is addressed by Monte Carlo simulations, covering the problem of MRS signal model......MRS of hyperpolarized 13C‐labeled compounds represents a promising technique for in vivo metabolic studies. However, robust quantification and metabolic modeling are still important areas of investigation. In particular, time and spatial resolution constraints may lead to the analysis of MRS...

  20. Improved stochastic resonance algorithm for enhancement of signal-to-noise ratio of high-performance liquid chromatographic signal

    International Nuclear Information System (INIS)

    Xie Shaofei; Xiang Bingren; Deng Haishan; Xiang Suyun; Lu Jun

    2007-01-01

    Based on the theory of stochastic resonance, an improved stochastic resonance algorithm with a new criterion for optimizing system parameters to enhance signal-to-noise ratio (SNR) of HPLC/UV chromatographic signal for trace analysis was presented in this study. Compared with the conventional criterion in stochastic resonance, the proposed one can ensure satisfactory SNR as well as good peak shape of chromatographic peak in output signal. Application of the criterion to experimental weak signals of HPLC/UV was investigated and the results showed an excellent quantitative relationship between different concentrations and responses

  1. Combining of Direct Search and Signal-to-Noise Ratio for economic dispatch optimization

    International Nuclear Information System (INIS)

    Lin, Whei-Min; Gow, Hong-Jey; Tsai, Ming-Tang

    2011-01-01

    This paper integrated the ideas of Direct Search and Signal-to-Noise Ratio (SNR) to develop a Novel Direct Search (NDS) method for solving the non-convex economic dispatch problems. NDS consists of three stages: Direct Search (DS), Global SNR (GSNR) and Marginal Compensation (MC) stages. DS provides a basic solution. GSNR searches the point with optimization strategy. MC fulfills the power balance requirement. With NDS, the infinite solution space becomes finite. Furthermore, a same optimum solution can be repeatedly reached. Effectiveness of NDS is demonstrated with three examples and the solutions were compared with previously published results. Test results show that the proposed method is simple, robust, and more effective than many other previously developed algorithms.

  2. Influence of Signal Stationarity on Digital Stochastic Measurement Implementation

    Directory of Open Access Journals (Sweden)

    Ivan Župunski

    2013-06-01

    Full Text Available The paper presents the influence of signal stationarity on digital stochastic measurement method implementation. The implementation method is based on stochastic voltage generators, analog adders, low resolution A/D converter, and multipliers and accumulators implemented by Field-Programmable Gate Array (FPGA. The characteristic of first implementations of digital stochastic measurement was the measurement of stationary signal harmonics over the constant measurement period. Later, digital stochastic measurement was extended and used also when it was necessary to measure timeseries of non-stationary signal over the variable measurement time. The result of measurement is the set of harmonics, which is, in the case of non-stationary signals, the input for calculating digital values of signal in time domain. A theoretical approach to determine measurement uncertainty is presented and the accuracy trends with varying signal-to-noise ratio (SNR are analyzed. Noisy brain potentials (spontaneous and nonspontaneous are selected as an example of real non-stationary signal and its digital stochastic measurement is tested by simulations and experiments. Tests were performed without noise and with adding noise with SNR values of 10dB, 0dB and - 10dB. The results of simulations and experiments are compared versus theory calculations, and comparasion confirms the theory.

  3. Theoretical Issues of Validity in the Measurement of Aided Speech Reception Threshold in Noise for Comparing Nonlinear Hearing Aid Systems.

    Science.gov (United States)

    Naylor, Graham

    2016-07-01

    Adaptive Speech Reception Threshold in noise (SRTn) measurements are often used to make comparisons between alternative hearing aid (HA) systems. Such measurements usually do not constrain the signal-to-noise ratio (SNR) at which testing takes place. Meanwhile, HA systems increasingly include nonlinear features that operate differently in different SNRs, and listeners differ in their inherent SNR requirements. To show that SRTn measurements, as commonly used in comparisons of alternative HA systems, suffer from threats to their validity, to illustrate these threats with examples of potentially invalid conclusions in the research literature, and to propose ways to tackle these threats. An examination of the nature of SRTn measurements in the context of test theory, modern nonlinear HAs, and listener diversity. Examples from the audiological research literature were used to estimate typical interparticipant variation in SRTn and to illustrate cases where validity may have been compromised. There can be no doubt that SRTn measurements, when used to compare nonlinear HA systems, in principle, suffer from threats to their internal and external/ecological validity. Interactions between HA nonlinearities and SNR, and interparticipant differences in inherent SNR requirements, can act to generate misleading results. In addition, SRTn may lie at an SNR outside the range for which the HA system is designed or expected to operate in. Although the extent of invalid conclusions in the literature is difficult to evaluate, examples of studies were nevertheless identified where the risk of each form of invalidity is significant. Reliable data on ecological SNRs is becoming available, so that ecological validity can be assessed. Methodological developments that can reduce the risk of invalid conclusions include variations on the SRTn measurement procedure itself, manipulations of stimulus or scoring conditions to place SRTn in an ecologically relevant range, and design and analysis

  4. Precise and accurate isotope ratio measurements by ICP-MS.

    Science.gov (United States)

    Becker, J S; Dietze, H J

    2000-09-01

    The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

  5. LITERATURE SURVEY ON ISOTOPIC ABUNDANCE RATIO MEASUREMENTS - 2001-2005

    International Nuclear Information System (INIS)

    HOLDEN, N.E.

    2005-01-01

    Along with my usual weekly review of the published literature for new nuclear data, I also search for new candidates for best measurements of isotopic abundances from a single source. Most of the published articles, that I previously had found in the Research Library at the Brookhaven Lab, have already been sent to the members of the Atomic Weights Commission, by either Michael Berglund or Thomas Walczyk. In the last few days, I checked the published literature for any other articles in the areas of natural variations in isotopic abundance ratios, measurements of isotopic abundance ratios on samples of extra-terrestrial material and isotopic abundance ratio measurements performed using ICPMS instruments. Hopefully this information will be of interest to members of the Commission, the sub-committee on isotopic abundance measurements (SIAM), members of the former sub-committee on natural isotopic fractionation (SNIF), the sub-committee on extra-terrestrial isotope ratios (SETIR), the RTCE Task Group and the Guidelines Task Group, who are dealing with ICPMS and TIMS comparisons. In the following report, I categorize the publications in one of four areas. Measurements performed using either positive or negative ions with Thermal Ionization Mass Spectrometer, TIMS, instruments; measurements performed on Inductively Coupled Plasma Mass Spectrometer, ICPMS, instruments; measurements of natural variations of the isotopic abundance ratios; and finally measurements on extra-terrestrial samples with instrumentation of either type. There is overlap in these areas. I selected out variations and ET results first and then categorized the rest of the papers by TIMS and ICPMS

  6. Recovery of a broken inspection lance from the reactor vessel of the German sodium cooled fast breeder reactor SNR 300

    International Nuclear Information System (INIS)

    Menck, J.W.; Hoeft, E.; Kirchner, G.

    1988-01-01

    An inspection lance for flow and vibration measurements was installed into the SNR-300 rotating plug. Centering and guiding of the lower end of the lance was effected in the central grid plate insert. The lance was torn off due to handling problems. The task consisted in recovering all defective parts from the reactor vessel and re-establishing the intact initial state. (author)

  7. Licensing aspects in the verification of the SNR 300 design concept against hypothetical accidents

    International Nuclear Information System (INIS)

    Kugler, E.; Wiesner, S.

    1976-01-01

    The German prototype of a fast breeder reactor, the SNR 300, is being built near Kalkar on the Lower Rhine. It is a loop-type fast sodium-cooled reactor, designed and constructed by Interatom, Bensberg. Experiences gained from the first phase of construction are described. The report is restricted to the aspects of the SNR 300 design against a core disruptive accident (CDA) and its consequences and to the difficulties having arisen in the verification of the design concept so far. Some examples of the detailed design are described and discussed from the licensing authority's point of view showing that the difficulties have been typical for a prototype reactor subjected to a regular licensing procedure

  8. IVA2 verification: Expansion phase experiment in SNR geometry

    International Nuclear Information System (INIS)

    Kolev, N.I.

    1987-09-01

    Using the IVA2/005 computer code the SNR model explosion experiment SGI-09-1 was numerically simulated. The experiment consists of high pressure gas injection into a low pressure liquid pool with a free surface in a cylindrical geometry with internals. Bubble formation and pressure history as a function of time was predicted and compared with the experimental observation. A good agreement between theory and experiment was obtained. Numerical diffusion and its influence on the results are discussed. (orig.) [de

  9. Impact of SNR, masker type and noise reduction processing on sentence recognition performance and listening effort as indicated by the pupil dilation response

    DEFF Research Database (Denmark)

    Ohlenforst, Barbara; Wendt, Dorothea; Kramer, Sophia E

    2018-01-01

    Recent studies have shown that activating the noise reduction scheme in hearing aids results in a smaller peak pupil dilation (PPD), indicating reduced listening effort, at 50% and 95% correct sentence recognition with a 4-talker masker. The objective of this study was to measure the effect...... of the noise reduction scheme (on or off) on PPD and sentence recognition across a wide range of signal-to-noise ratios (SNRs) from +16 dB to -12 dB and two masker types (4-talker and stationary noise). Relatively low PPDs were observed at very low (-12 dB) and very high (+16 dB to +8 dB) SNRs presumably due...... to 'giving up' and 'easy listening', respectively. The maximum PPD was observed with SNRs at approximately 50% correct sentence recognition. Sentence recognition with both masker types was significantly improved by the noise reduction scheme, which corresponds to the shift in performance from SNR function...

  10. SNR-300 steam generator accident philosophy - Assessment due to new understandings in Na/H20-reactions

    International Nuclear Information System (INIS)

    Ruloff, G.; Huebner, R.

    1990-01-01

    Recent R+D results in the intermediate leak range (finally confirmed by the PFR steam generator accident) lead to a new assessment for the SNR-300 steam generator accident. This paper discusses the course of such accident which has to be expected under the SNR-300 conditions, starting with an unblocked micro leak and ending with the pressure loads on the secondary system due to overheating failure. Also, enclosed are the possibilities for a leak detection before serious damage has occurred and the discussion of the definition of the DBA. (author). 2 refs, 9 figs

  11. On the origin of the system PSR B1757-24/SNR G5.4-1.2

    OpenAIRE

    Gvaramadze, V. V.

    2003-01-01

    A scenario for the origin of the system PSR B1757-24/supernova remnant (SNR) G5.4-1.2 is proposed. It is suggested that both objects are the remnants of a supernova (SN) that exploded within a pre-existing bubble blown-up by a runaway massive star (the SN progenitor) during the final (Wolf-Rayet) phase of its evolution. This suggestion implies that (a) the SN blast centre was significantly offset from the geometric centre of the wind-blown bubble (i.e. from the centre of the future SNR), (b) ...

  12. The split symbol moments SNR estimator in narrow-band channels

    Science.gov (United States)

    Shah, Biren; Hinedi, Sami

    1990-01-01

    The split symbol moments estimator is an algorithm that is designed to estimate symbol SNR in the presence of additive white Gaussian noise. The performance of the algorithm in band-limited channels is examined, and the effects of the resulting intersymbol interference are quantified. All results obtained are in closed form and can be easily evaluated numerically for performance-prediction purposes. The results are also validated through digital simulations.

  13. Improving Signal-to-Noise Ratio in Susceptibility Weighted Imaging: A Novel Multicomponent Non-Local Approach.

    Directory of Open Access Journals (Sweden)

    Pasquale Borrelli

    Full Text Available In susceptibility-weighted imaging (SWI, the high resolution required to obtain a proper contrast generation leads to a reduced signal-to-noise ratio (SNR. The application of a denoising filter to produce images with higher SNR and still preserve small structures from excessive blurring is therefore extremely desirable. However, as the distributions of magnitude and phase noise may introduce biases during image restoration, the application of a denoising filter is non-trivial. Taking advantage of the potential multispectral nature of MR images, a multicomponent approach using a Non-Local Means (MNLM denoising filter may perform better than a component-by-component image restoration method. Here we present a new MNLM-based method (Multicomponent-Imaginary-Real-SWI, hereafter MIR-SWI to produce SWI images with high SNR and improved conspicuity. Both qualitative and quantitative comparisons of MIR-SWI with the original SWI scheme and previously proposed SWI restoring pipelines showed that MIR-SWI fared consistently better than the other approaches. Noise removal with MIR-SWI also provided improvement in contrast-to-noise ratio (CNR and vessel conspicuity at higher factors of phase mask multiplications than the one suggested in the literature for SWI vessel imaging. We conclude that a proper handling of noise in the complex MR dataset may lead to improved image quality for SWI data.

  14. Computer-controlled detection system for high-precision isotope ratio measurements

    International Nuclear Information System (INIS)

    McCord, B.R.; Taylor, J.W.

    1986-01-01

    In this paper the authors describe a detection system for high-precision isotope ratio measurements. In this new system, the requirement for a ratioing digital voltmeter has been eliminated, and a standard digital voltmeter interfaced to a computer is employed. Instead of measuring the ratio of the two steadily increasing output voltages simultaneously, the digital voltmeter alternately samples the outputs at a precise rate over a certain period of time. The data are sent to the computer which calculates the rate of charge of each amplifier and divides the two rates to obtain the isotopic ratio. These results simulate a coincident measurement of the output of both integrators. The charge rate is calculated by using a linear regression method, and the standard error of the slope gives a measure of the stability of the system at the time the measurement was taken

  15. Influence of Signal-to-Noise Ratio and Point Spread Function on Limits of Super-Resolution

    NARCIS (Netherlands)

    Pham, T.Q.; Vliet, L.J. van; Schutte, K.

    2005-01-01

    This paper presents a method to predict the limit of possible resolution enhancement given a sequence of low resolution images. Three important parameters influence the outcome of this limit: the total Point Spread Function (PSF), the Signal-to-Noise Ratio (SNR) and the number of input images.

  16. Influence of signal-to-noise ratio and point spread function on limits of super-resolution

    NARCIS (Netherlands)

    Pham, T.Q.; Van Vliet, L.; Schutte, K.

    2005-01-01

    This paper presents a method to predict the limit of possible resolution enhancement given a sequence of lowresolution images. Three important parameters influence the outcome of this limit: the total Point Spread Function (PSF), the Signal-to-Noise Ratio (SNR) and the number of input images.

  17. A HOS-based blind deconvolution algorithm for the improvement of time resolution of mixed phase low SNR seismic data

    International Nuclear Information System (INIS)

    Hani, Ahmad Fadzil M; Younis, M Shahzad; Halim, M Firdaus M

    2009-01-01

    A blind deconvolution technique using a modified higher order statistics (HOS)-based eigenvector algorithm (EVA) is presented in this paper. The main purpose of the technique is to enable the processing of low SNR short length seismograms. In our study, the seismogram is assumed to be the output of a mixed phase source wavelet (system) driven by a non-Gaussian input signal (due to earth) with additive Gaussian noise. Techniques based on second-order statistics are shown to fail when processing non-minimum phase seismic signals because they only rely on the autocorrelation function of the observed signal. In contrast, existing HOS-based blind deconvolution techniques are suitable in the processing of a non-minimum (mixed) phase system; however, most of them are unable to converge and show poor performance whenever noise dominates the actual signal, especially in the cases where the observed data are limited (few samples). The developed blind equalization technique is primarily based on the EVA for blind equalization, initially to deal with mixed phase non-Gaussian seismic signals. In order to deal with the dominant noise issue and small number of available samples, certain modifications are incorporated into the EVA. For determining the deconvolution filter, one of the modifications is to use more than one higher order cumulant slice in the EVA. This overcomes the possibility of non-convergence due to a low signal-to-noise ratio (SNR) of the observed signal. The other modification conditions the cumulant slice by increasing the power of eigenvalues of the cumulant slice, related to actual signal, and rejects the eigenvalues below the threshold representing the noise. This modification reduces the effect of the availability of a small number of samples and strong additive noise on the cumulant slices. These modifications are found to improve the overall deconvolution performance, with approximately a five-fold reduction in a mean square error (MSE) and a six

  18. Fast fission ratio and relative conversion ratio measurements in gadolinium poisoned water moderated UO2 lattices

    International Nuclear Information System (INIS)

    Murphy, M.F.

    1984-01-01

    A programme of criticality experiments has been carried out for BNFL by the Battelle reactor facility at Pacific Northwest Laboratories in Washington State, USA. A series of water moderated lattices of 4.3% enriched, 12.7 mm diameter, UO 2 fuel rods was studied, the fuel pitch was varied and the effects of gadolinium poison were measured. This report deals with the measurement of Fast Fission Ratios and Relative Conversion Ratios at the centre of five of the critical lattices. The Fast Fission Ratio (FFR) is defined here as the ratio of the fission rate per atom of U238, to the fission rate per atom of U235. The Relative Conversion Ratio (RCR) is defined as the ratio of the capture rate per ,atom of U238, to the fission rate per atom of U235, in the reactor fuel, relative to the corresponding ratio in a well thermalised neutron spectrum. A major aspect of these measurements was that the packs of foils were prepared at AEEW Winfrith, despatched to the USA for irradiation and returned to Winfrith for counting. This resulted in a considerable logistics problem but by good planning and the co-operation and diligence of all concerned this problem was overcome. However, the long distance involved inevitably meant that samples were not available for measurement until about 28 hours after the irradiation. It was therefore necessary to modify the techniques that are normally used in the Reactor Physics Division Counting Laboratory, where samples are normally available about two hours after shut-down. The techniques used and the results obtained are given below

  19. Constraining lowermost mantle structure with PcP/P amplitude ratios from large aperture arrays

    Science.gov (United States)

    Ventosa, S.; Romanowicz, B. A.

    2015-12-01

    Observations of weak short-period teleseismic body waves help to resolve lowermost mantle structure at short wavelengths, which is essential for understanding mantle dynamics and the interactions between the mantle and core. Their limited amount and uneven distribution are however major obstacles to solve for volumetric structure of the D" region, topography of the core-mantle boundary (CMB) and D" discontinuity, and the trade-offs among them. While PcP-P differential travel times provide important information, there are trade-offs between velocity structure and core-mantle boundary topography, which PcP/P amplitude ratios can help resolve, as long as lateral variations in attenuation and biases due to focusing are small or can be corrected for. Dense broadband seismic networks help to improve signal-to-noise ratio (SNR) of the target phases and signal-to-interference ratio (SIR) of other mantle phases when the slowness difference is large enough. To improve SIR and SNR of teleseismic PcP data, we have introduced the slant-stacklet transform to define coherent-guided filters able to separate and enhance signals according to their slowness, time of arrival and frequency content. We thus obtain optimal PcP/P amplitude ratios in the least-square sense using two short sliding windows to match the P signal with a candidate PcP signal. This method allows us to dramatically increase the amount of high-quality observations of short-period PcP/P amplitude ratios by allowing for smaller events and wider epicentral distance and depth ranges.We present the results of measurement of PcP/P amplitude ratios, sampling regions around the Pacific using dense arrays in North America and Japan. We observe that short-period P waves traveling through slabs are strongly affected by focusing, in agreement with the bias we have observed and corrected for due to mantle heterogeneities on PcP-P travel time differences. In Central America, this bias is by far the stronger anomaly we observe

  20. 1H-MRS evaluation of breast lesions by using total choline signal-to-noise ratio as an indicator of malignancy: a meta-analysis.

    Science.gov (United States)

    Wang, Xin; Wang, Xiang Jiang; Song, Hui Sheng; Chen, Long Hua

    2015-05-01

    The aim of this study was to evaluate the diagnostic performance of the use of total choline signal-to-noise ratio (tCho SNR) criteria in MRS studies for benign/malignant discrimination of focal breast lesions. We conducted (1) a meta-analysis based on 10 studies including 480 malignant breast lesions and 312 benign breast lesions and (2) a subgroup meta-analysis of tCho SNR ≥ 2 as cutoff for malignancy based on 7 studies including 371 malignant breast lesions and 239 benign breast lesions. (1) The pooled sensitivity and specificity of proton MRS with tCho SNR were 0.74 (95 % CI 0.69-0.77) and 0.76 (95 % CI 0.71-0.81), respectively. The PLR and NLR were 3.67 (95 % CI 2.30-5.83) and 0.25 (95 % CI 0.14-0.42), respectively. From the fitted SROC, the AUC and Q* index were 0.89 and 0.82. Publication bias was present (t = 2.46, P = 0.039). (2) Meta-regression analysis suggested that neither threshold effect nor evaluated covariates including strength of field, pulse sequence, TR and TE were sources of heterogeneity (all P value >0.05). (3) Subgroup meta-analysis: The pooled sensitivity and specificity were 0.79 and 0.72, respectively. The PLR and NLR were 3.49 and 0.20, respectively. The AUC and Q* index were 0.92 and 0.85. The use of tCho SNR criteria in MRS studies was helpful for differentiation between malignant and benign breast lesions. However, pooled diagnostic measures might be overestimated due to publication bias. A tCho SNR ≥ 2 as cutoff for malignancy resulted in higher diagnostic accuracy.

  1. Measurements of K/Π ratio in cosmic radiation

    International Nuclear Information System (INIS)

    Mahon, J.R.P.

    1986-01-01

    Measurements of k/Π ratio in cosmic radiation by its half lives and its fluxes, were carried out. The kaon flux was obtained using the Cherenkov detector, and for pion flux scintillation detectors were used. The final results of K/Π ratio ∼ 0.2 was obtained. (M.C.K.) [pt

  2. Turning Fiction Into Non-fiction for Signal-to-Noise Ratio Estimation -- The Time-Multiplexed and Adaptive Split-Symbol Moments Estimator

    Science.gov (United States)

    Simon, M.; Dolinar, S.

    2005-08-01

    A means is proposed for realizing the generalized split-symbol moments estimator (SSME) of signal-to-noise ratio (SNR), i.e., one whose implementation on the average allows for a number of subdivisions (observables), 2L, per symbol beyond the conventional value of two, with other than an integer value of L. In theory, the generalized SSME was previously shown to yield optimum performance for a given true SNR, R, when L=R/sqrt(2) and thus, in general, the resulting estimator was referred to as the fictitious SSME. Here we present a time-multiplexed version of the SSME that allows it to achieve its optimum value of L as above (to the extent that it can be computed as the average of a sum of integers) at each value of SNR and as such turns fiction into non-fiction. Also proposed is an adaptive algorithm that allows the SSME to rapidly converge to its optimum value of L when in fact one has no a priori information about the true value of SNR.

  3. Measurement of the super-allowed branching ratio of $^{22}$Mg

    CERN Multimedia

    We propose to measure the super-allowed branching ratio and the half-life of $^{22}$Mg, one of the least-well-measured $0^{+} \\rightarrow 0^{+}$ transitions of the 14 nuclei used to determine V$_{ud}$ and to test the unitarity of the CKM matrix. We propose measurements which should allow to significantly improve the precision on the super-allowed branching ratio employing a precisely efficiency calibrated germanium detector and on the half-life. As no method exists to greatly improve (e.g. an order of magnitude) on previous results, the branching ratio and the half-life have to be measured several times with independent methods and in independent experiments.

  4. New method to extract radial acceleration of target from short-duration signal at low SNR

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In order to extract target radial acceleration from radar echo signal at low SNR (signal-to-noise), this paper employed FRFT (fractional Fourier transformation) to analyze short-duration radar echo and studied the relations between signal convergence peaks in matched transformation domain and signal duration and modu- lated frequency of signal. When signal duration is specified, the method of multi- plying sampled signal by the known frequency modulated signal to alter modulated frequency was presented, which generated the new signal with larger convergence peaks than the initial signal in matched transformation domain. Thus, it could successfully estimate the radial acceleration of radar target at low SNR. Simulations were conducted to show the feasibility and effectiveness of the method.

  5. Optimized optical wireless channel for indoor and intra-vehicle communications: power distribution and SNR analysis

    Science.gov (United States)

    Shaaban, Rana; Faruque, Saleh

    2018-01-01

    Light emitting diodes - LEDs are modernizing the indoor illumination and replacing current incandescent and fluorescent lamps rapidly. LEDs have multiple advantages such as extremely high energy efficient, longer lifespan, and lower heat generation. Due to the ability to switch to different light intensity at a very fast rate, LED has given rise to a unique communication technology (visible light communication - VLC) used for high speed data transmission. By studying various kinds of commonly used VLC channel analysis: diffuse and line of sight channels, we presented a simply improved indoor and intra-vehicle visible light communication transmission model. Employing optical wireless communications within the vehicle, not only enhance user mobility, but also alleviate radio frequency interference, and increase efficiency by lowering the complexity of copper cabling. Moreover, a solution to eliminate ambient noise caused by environmental conditions is examined by using optical differential receiver. The simulation results show the improved received power distribution and signal to noise ratio - SNR.

  6. Parallel Array Bistable Stochastic Resonance System with Independent Input and Its Signal-to-Noise Ratio Improvement

    Directory of Open Access Journals (Sweden)

    Wei Li

    2014-01-01

    with independent components and averaged output; second, we give a deduction of the output signal-to-noise ratio (SNR for this system to show the performance. Our examples show the enhancement of the system and how different parameters influence the performance of the proposed parallel array.

  7. Variable impact of CSF flow suppression on quantitative 3.0T intracranial vessel wall measurements.

    Science.gov (United States)

    Cogswell, Petrice M; Siero, Jeroen C W; Lants, Sarah K; Waddle, Spencer; Davis, L Taylor; Gilbert, Guillaume; Hendrikse, Jeroen; Donahue, Manus J

    2018-03-31

    Flow suppression techniques have been developed for intracranial (IC) vessel wall imaging (VWI) and optimized using simulations; however, simulation results may not translate in vivo. To evaluate experimentally how IC vessel wall and lumen measurements change in identical subjects when evaluated using the most commonly available blood and cerebrospinal fluid (CSF) flow suppression modules and VWI sequences. Prospective. Healthy adults (n = 13; age = 37 ± 15 years) were enrolled. A 3.0T 3D T 1 /proton density (PD)-weighted turbo-spin-echo (TSE) acquisition with post-readout anti-driven equilibrium module, with and without Delay-Alternating-with-Nutation-for-Tailored-Excitation (DANTE) was applied. DANTE flip angle (8-12°) and TSE refocusing angle (sweep = 40-120° or 50-120°) were varied. Basilar artery and internal carotid artery (ICA) wall thicknesses, CSF signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal ratio (SR) were assessed. Measurements were made by two readers (radiology resident and board-certified neuroradiologist). A Wilcoxon signed-rank test was applied with corrected two-sided P CSF suppression. Addition of the DANTE preparation reduced CSF SNR from 17.4 to 6.7, thereby providing significant (P CSF suppression. The DANTE preparation also resulted in a significant (P CSF CNR improvement (P = 0.87). There was a trend for a difference in blood SNR with vs. without DANTE (P = 0.05). The outer vessel wall diameter and wall thickness values were lower (P CSF suppression and CNR of the approaches evaluated. However, improvements are heterogeneous, likely owing to intersubject vessel pulsatility and CSF flow variations, which can lead to variable flow suppression efficacy in these velocity-dependent modules. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  8. Star Forming Dense Cloud Cores in the TeV -ray SNR RX J1713.7-3946

    Energy Technology Data Exchange (ETDEWEB)

    Sano, H.; Sato, J.; Yamamoto, H.; Hayakawa, T.; Torii, K.; Moribe, N.; Kawamura, A.; Okuda, T.; Mizuno, N.; Onishi, T.; Maezawa, H.; Inoue, T.; Inutsuka, S.; Tanaka, T.; Mizuno, A.; Ogawa, H.; Stutzki, J.; Bertoldi, F.; Anderl, S.; Bronfman, L.; Koo, B.C.

    2010-10-27

    RX J1713.7-3946 is one of the TeV {gamma}-ray supernova remnants (SNRs) emitting synchrotron X rays. The SNR is associated with molecular gas located at {approx}1 kpc. We made new molecular observations toward the dense cloud cores, peaks A, C and D, in the SNR in the {sup 12}CO(J=2-1) and {sup 13}CO(J=2-1) transitions at angular resolution of 90 degrees. The most intense core in {sup 13}CO, peak C, was also mapped in the {sup 12}CO(J=4-3) transition at angular resolution of 38 degrees. Peak C shows strong signs of active star formation including bipolar outflow and a far-infrared protostellar source and has a steep gradient with a r{sup -2.2 {+-} 0.4} variation in the average density within radius r. Peak C and the other dense cloud cores are rim-brightened in synchrotron X rays, suggesting that the dense cloud cores are embedded within or on the outer boundary of the SNR shell. This confirms the earlier suggestion that the X rays are physically associated with the molecular gas (Fukui et al. 2003). We present a scenario where the densest molecular core, peak C, survived against the blast wave and is now embedded within the SNR. Numerical simulations of the shock-cloud interaction indicate that a dense clump can indeed survive shock erosion, since shock propagation speed is stalled in the dense clump. Additionally, the shock-cloud interaction induces turbulence and magnetic field amplification around the dense clump that may facilitate particle acceleration in the lower-density inter-clump space leading to the enhanced synchrotron X rays around dense cores.

  9. Measurement of the temperature coefficient of ratio transformers

    Science.gov (United States)

    Briggs, Matthew E.; Gammon, Robert W.; Shaumeyer, J. N.

    1993-01-01

    We have measured the temperature coefficient of the output of several ratio transformers at ratios near 0.500,000 using an ac bridge and a dual-phase, lock-in amplifier. The two orthogonal output components were each resolved to +/- ppb of the bridge drive signal. The results for three commercial ratio transformers between 20 and 50 C range from 0.5 to 100 ppb/K for the signal component in phase with the bridge drive, and from 4 to 300 ppb/K for the quadrature component.

  10. Multi-reception strategy with improved SNR for multichannel MR imaging.

    Directory of Open Access Journals (Sweden)

    Bing Wu

    Full Text Available A multi-reception strategy with extended GRAPPA is proposed in this work to improve MR imaging performance at ultra-high field MR systems with limited receiver channels. In this method, coil elements are separated to two or more groups under appropriate grouping criteria. Those groups are enabled in sequence for imaging first, and then parallel acquisition is performed to compensate for the redundant scan time caused by the multiple receptions. To efficiently reconstruct the data acquired from elements of each group, a specific extended GRAPPA was developed. This approach was evaluated by using a 16-element head array on a 7 Tesla whole-body MRI scanner with 8 receive channels. The in-vivo experiments demonstrate that with the same scan time, the 16-element array with twice receptions and acceleration rate of 2 can achieve significant SNR gain in the periphery area of the brain and keep nearly the same SNR in the center area over an eight-element array, which indicates the proposed multi-reception strategy and extended GRAPPA are feasible to improve image quality for MRI systems with limited receive channels. This study also suggests that it is advantageous for a MR system with N receiver channels to utilize a coil array with more than N elements if an appropriate acquisition strategy is applied.

  11. Regional improvement of signal-to-noise and contrast-to-noise ratios in dual-screen CR chest imaging - a phantom study

    International Nuclear Information System (INIS)

    Liu Xinming; Shaw, Chris C.

    2001-01-01

    The improvement of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in dual-screen computed radiography (CR) has been investigated for various regions in images of an anthropomorphic chest phantom. With the dual-screen CR technique, two image plates are placed in a cassette and exposed together during imaging. The exposed plates are separately scanned to form a front image and a back image, which are then registered and superimposed to form a composite image with improved SNRs and CNRs. The improvement can be optimized by applying specifically selected weighting factors during superimposition. In this study, dual-screen CR images of an anthropomorphic chest phantom were acquired and formed with four different combinations of standard resolution (ST) and high-resolution (HR) screens: ST-ST, ST-HR, HR-ST, and HR-HR. SNRs and their improvements were measured and compared over twelve representative regions-of-interest (ROIs) in these images. A 19.1%-45.7% increase of the SNR was observed, depending on the ROI and screen combination used. The optimal weighting factors were found to vary by only 4.5%-12.4%. Largest improvement was found in the lung field for all screen combinations. Improvement of CNRs was investigated over two ROIs in the lung field using the rib bones as the contrast objects and a 29.2%-43.9% improvement of the CNR was observed. Among the four screen combinations, ST-ST resulted in the most SNR and CNR improvement, followed in order by HR-ST, HR-HR, and ST-HR. The HR-ST combination yielded the lowest spatial variation of the optimal weighting factors with improved SNRs and CNRs close to those of the ST-ST combination

  12. Stable isotope ratio measurements in hydrogen, nitrogen, and oxygen using Raman scattering

    International Nuclear Information System (INIS)

    Harney, R.C.; Bloom, S.D.; Milanovich, F.P.

    1975-01-01

    A method for measuring stable isotope ratios using laser Raman scattering was developed which may prove of significant utility and benefit in stable isotope tracer studies. Crude isotope ratio measurements obtained with a low-power laser indicate that with current technology it should be possible to construct an isotope ratio measurement system using laser Raman scattering that is capable of performing 0.1 percent accuracy isotope ratio measurements of 16 O/ 18 O in natural abundance oxygen gas or 14 N/ 15 N in natural abundance nitrogen gas in times less than two minutes per sample. Theory pertinent to the technique, designs of specific isotope ratio spectrometer systems, and data relating to isotope ratio measurements in hydrogen, nitrogen, and oxygen are presented. In addition, the current status of several studies utilizing this technique is discussed. (auth)

  13. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, A. [Shenzhen College of International Education, 1st HuangGang Park St., Shenzhen, GuangDong (China); Luo, J. [Department of Biomedical Engineering, University at Buffalo, 332 Bonner Hall, Buffalo, NY 14260-1920 (United States); Wang, A. [Department of Computer Science, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Broadbent, C. [School of Engineering, Columbia University, 1130 Amsterdam Av., New York, NY 10027 (United States); Zhong, J. [Department of English, Dartmouth College, 6032 Sanborn House, Hanover, NH 03755 (United States); Dilmanian, F.A. [Departments of Radiation Oncology, Neurology, and Radiology, Stony Brook University, Stony Brook, NY 11794 (United States); Zafonte, F.; Zhong, Z. [National Synchrotron Light Source II, Brookhaven National Laboratory, Bldg. 743, Upton, NY 11973 (United States)

    2015-07-11

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. An efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

  14. Measurement of boron isotope ratios in groundwater studies

    International Nuclear Information System (INIS)

    Porteous, N.C.; Walsh, J.N.; Jarvis, K.E.

    1995-01-01

    Boron is present at low levels in groundwater and rainfall in the UK, ranging between 2 and 200 ng ml -1 . A sensitive technique has been developed using inductively coupled plasma mass spectrometry (ICP-MS) to measure boron isotope ratios at low concentrations with a precision (s r ) of between 0.1 and 0.2%. Samples were evaporated to increase elemental boron concentrations to 200 ng ml -1 and interfering matrix elements were removed by an adapted cation-exchange separation procedure. The validity of measuring boron isotopic ratios by ICP-MS at this concentration level is discussed in relation to the theoretical instrument precision attainable based on counting statistics. (author)

  15. Measurement of the inclusive charmless and double-charm B branching ratios

    CERN Document Server

    Abreu, P; Adye, T; Adzic, P; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andersson, P; Andreazza, A; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barbier, R; Bardin, Dimitri Yuri; Barker, G; Baroncelli, A; Bärring, O; Bates, M J; Battaglia, Marco; Baubillier, M; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Bérat, C; Berggren, M; Bertini, D; Bertrand, D; Besançon, M; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bizouard, M A; Bloch, D; Bonesini, M; Bonivento, W; Boonekamp, M; Booth, P S L; Borgland, A W; Borisov, G; Bosio, C; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozovic, I; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Brown, R; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerruti, C; Chabaud, V; Chapkin, M M; Charpentier, P; Chaussard, L; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Chudoba, J; Collins, P; Colomer, M; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Cowell, J H; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; D'Almagne, B; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; Dijkstra, H; Di Ciaccio, Lucia; Di Diodato, A; Djannati, A; Dolbeau, J; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Duperrin, A; Durand, J D; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Ellert, M; Elsing, M; Engel, J P; Erzen, B; Espirito-Santo, M C; Falk, E; Fanourakis, G K; Fassouliotis, D; Fayot, J; Feindt, Michael; Fenyuk, A; Ferrari, P; Ferrer, A; Fichet, S; Firestone, A; Fischer, P A; Flagmeyer, U; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gaspar, M; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gerdyukov, L N; Ghodbane, N; Glege, F; Gokieli, R; Golob, B; González-Caballero, I; Gopal, Gian P; Gorn, L; Górski, M; Gracco, Valerio; Grahl, J; Graziani, E; Green, C; Grefrath, A; Gris, P; Grosdidier, G; Grzelak, K; Günther, M; Guy, J; Hahn, F; Hahn, S; Haider, S; Hajduk, Z; Hallgren, A; Hamacher, K; Harris, F J; Hedberg, V; Heising, S; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Heuser, J M; Higón, E; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, C; Juillot, P; Kapusta, F; Karafasoulis, K; Katsanevas, S; Katsoufis, E C; Keränen, R; Khokhlov, Yu A; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klapp, O; Klein, H; Kluit, P M; Knoblauch, D; Kokkinias, P; Koratzinos, M; Korcyl, K; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leisos, A; Leitner, R; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Lethuillier, M; Libby, J; Liko, D; Lipniacka, A; Lippi, I; Lörstad, B; Loken, J G; Lopes, J H; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Mahon, J R; Maio, A; Malek, A; Malmgren, T G M; Malychev, V; Mandl, F; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, F; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; McPherson, G; Medbo, J; Meroni, C; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Moreau, X; Morettini, P; Münich, K; Mulders, M; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Myklebust, T; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Némécek, S; Neufeld, N; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Nikolenko, M; Niss, P; Nomerotski, A; Normand, Ainsley; Nygren, A; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Orazi, G; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Paiano, S; Pain, R; Paiva, R; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Parzefall, U; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Piotto, E; Podobnik, T; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Reinhardt, R; Renton, P B; Resvanis, L K; Richard, F; Rídky, J; Rinaudo, G; Røhne, O M; Romero, A; Ronchese, P; Rosenberg, E I; Rosinsky, P; Roudeau, Patrick; Rovelli, T; Ruhlmann-Kleider, V; Ruiz, A; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sampsonidis, D; Sannino, M; Schneider, H; Schwickerath, U; Schyns, M A E; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Sekulin, R L; Shellard, R C; Sheridan, A; Silvestre, R; Simonetto, F; Sissakian, A N; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Solovyanov, O; Sopczak, André; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stampfer, D; Stanescu, C; Stanic, S; Stapnes, Steinar; Stavitski, I; Stevenson, K; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Chikilev, O G; Tegenfeldt, F; Terranova, F; Thomas, J; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Todorova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; van Apeldoorn, G W; van Dam, P; Van Eldik, J; Van Lysebetten, A; Van Vulpen, I B; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Verzi, V; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Waldner, F; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Wlodek, T; Wolf, G; Yi, J; Yushchenko, O P; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zucchelli, G C; Zumerle, G

    1998-01-01

    The DELPHI experiment at LEP has measured the inclusive charmless $B$ hadron decay branching ratio, the $B$ branching ratio into two charmed particles, and the total number of charmed particles per $B$ decay, using the hadronic Z data taken between 1992 and 1995. The results are extracted from a fit to the $b$-tagging probability distribution based on the precise impact parameter measurements made using the microvertex detector. The inclusive charmless $B$ branching ratio, including $B$ decays into hidden charm ($c\\bar{c}$), is measured to be $0.033 \\pm 0.021$. The $B$ branching ratio into two open charmed particles is $0.136 \\pm 0.042$. The mean number of charmed particles per $B$ decay (including hidden charm) is $1.147 \\pm 0.041$. After subtracting the $B$ decay branching ratio into hidden charm, the charmless $B$ branching ratio is found to be $0.007 \\pm 0.021$, compatible with the Standard Model expectation. Models that predict an additional contribution to the charmless $B$ branching ratio of 0.037 or h...

  16. Measurement of the super-allowed branching ratio of $^{10}$C

    CERN Multimedia

    We propose to measure the super-allowed branching ratio of $^{10}$C, the lightest of all nuclei decaying by a $0^{+} \\rightarrow 0^{+}$ transition. The light nuclei have a much stronger impact on limits of physics beyond the standard model than heavier nuclei. We propose a measurement which should reach a precision similar to the two latest measurements, however, with a different method employing a precisely efficiency-calibrated germanium detector. As no method exists to greatly improve on previous results, the branching ratio has to be measured with independent methods.

  17. Phasor Measurement Unit under Interference Conditions

    DEFF Research Database (Denmark)

    Ghiga, Radu; Martin, Kenneth E.; Wu, Qiuwei

    2017-01-01

    interference condition scenarios. In the first scenario, noise is added to the PMU input signal. The test runs a sweep of Signalto-Noise Ratios (SNR) and the accuracy versus the noise level is obtained. The second scenario injects multiple harmonics with the input to test the influence on accuracy. The last...... scenario focuses on instrument transformer saturation which leads to a modified waveform injected in the PMU. This test goes through different levels of Current Transformer (CT) saturation and analyzes the effect of saturation on the accuracy of PMUs. The test results show PMU measurements will be degraded...

  18. Nondestructive measurement of the grid ratio using a single image

    International Nuclear Information System (INIS)

    Pasciak, A. S.; Jones, A. Kyle

    2009-01-01

    The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (T p ), and scatter transmission (T s ). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53±0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

  19. Combination of fat saturation and variable bandwidth imaging to increase signal-to-noise ratio and decrease motion artifacts for body MR imaging at high field

    International Nuclear Information System (INIS)

    Chew, W.M.

    1989-01-01

    The signal-to-noise ratio (SNR) of the MR imaging examination is a critical component of the quality of the image. Standard methods to increase SNR include signal averaging with multiple excitations, at the expense of imaging time (which on T2-weighted images could be quite significant), or increasing pixel volume by manipulation of field of view, matrix size, and/or section thickness, all at the expense of resolution. Another available method to increase SNR is to reduce the bandwidth of the receiver, which increases SNR by the square root of the amount of the reduction. The penalty imposed on high-field-strength MR examinations of the body is an unacceptable increase in chemical shift artifact. However, presaturating the fat resonance eliminates the chemical shift artifact. Thus, a combination of imaging techniques, fat suppression, and decreased bandwidth imaging can produce images free of chemical shift artifact with increased SNR and no penalty in resolution or imaging time. Early studies also show a reduction in motion artifact when fat saturation is used. This paper reports MR imaging performed with a 1.5-T Signa imager. With this technique, T2-weighted images (2,500/20/80 [repetition time msec/echo time msec/inversion time msec]) illustrating the increase in SNR and T1-weighted images (600/20) demonstrating a decrease in motion artifact are shown

  20. YOUNG REMNANTS OF TYPE Ia SUPERNOVAE AND THEIR PROGENITORS: A STUDY OF SNR G1.9+0.3

    International Nuclear Information System (INIS)

    Chakraborti, Sayan; Childs, Francesca; Soderberg, Alicia

    2016-01-01

    SNe Ia, with their remarkably homogeneous light curves and spectra, have been used as standardizable candles to measure the accelerating expansion of the universe. Yet, their progenitors remain elusive. Common explanations invoke a degenerate star (white dwarf) that explodes upon almost reaching the Chandrasekhar limit, by either steadily accreting mass from a companion star or violently merging with another degenerate star. We show that circumstellar interaction in young Galactic supernova remnants can be used to distinguish between these single and double degenerate (DD) progenitor scenarios. Here we propose a new diagnostic, the surface brightness index, which can be computed from theory and compared with Chandra and Very Large Array (VLA) observations. We use this method to demonstrate that a DD progenitor can explain the decades-long flux rise and size increase of the youngest known galactic supernova remnant (SNR), G1.9+0.3. We disfavor a single degenerate scenario for SNR G1.9+0.3. We attribute the observed properties to the interaction between a steep ejecta profile and a constant density environment. We suggest using the upgraded VLA, ASKAP, and MeerKAT to detect circumstellar interaction in the remnants of historical SNe Ia in the Local Group of galaxies. This may settle the long-standing debate over their progenitors

  1. YOUNG REMNANTS OF TYPE Ia SUPERNOVAE AND THEIR PROGENITORS: A STUDY OF SNR G1.9+0.3

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborti, Sayan; Childs, Francesca; Soderberg, Alicia, E-mail: schakraborti@post.harvard.edu [Institute for Theory and Computation, Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2016-03-01

    SNe Ia, with their remarkably homogeneous light curves and spectra, have been used as standardizable candles to measure the accelerating expansion of the universe. Yet, their progenitors remain elusive. Common explanations invoke a degenerate star (white dwarf) that explodes upon almost reaching the Chandrasekhar limit, by either steadily accreting mass from a companion star or violently merging with another degenerate star. We show that circumstellar interaction in young Galactic supernova remnants can be used to distinguish between these single and double degenerate (DD) progenitor scenarios. Here we propose a new diagnostic, the surface brightness index, which can be computed from theory and compared with Chandra and Very Large Array (VLA) observations. We use this method to demonstrate that a DD progenitor can explain the decades-long flux rise and size increase of the youngest known galactic supernova remnant (SNR), G1.9+0.3. We disfavor a single degenerate scenario for SNR G1.9+0.3. We attribute the observed properties to the interaction between a steep ejecta profile and a constant density environment. We suggest using the upgraded VLA, ASKAP, and MeerKAT to detect circumstellar interaction in the remnants of historical SNe Ia in the Local Group of galaxies. This may settle the long-standing debate over their progenitors.

  2. Measurement of Tau Branching Ratios to Five Charged Hadrons

    CERN Document Server

    Ackerstaff, K.; Allison, John; Altekamp, N.; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Bartoldus, R.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bird, S.D.; Blobel, V.; Bloodworth, I.J.; Bobinski, M.; Bock, P.; Bohme, J.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brown, Robert M.; Burckhart, H.J.; Burgard, C.; Burgin, R.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Davis, R.; De Jong, S.; del Pozo, L.A.; De Roeck, A.; Desch, K.; Dienes, B.; Dixit, M.S.; Doucet, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Eatough, D.; Estabrooks, P.G.; Etzion, E.; Evans, H.G.; Fabbri, F.; Fanfani, A.; Fanti, M.; Faust, A.A.; Fiedler, F.; Fierro, M.; Fischer, H.M.; Fleck, I.; Folman, R.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gascon, J.; Gascon-Shotkin, S.M.; Geich-Gimbel, C.; Geralis, T.; Giacomelli, G.; Giacomelli, P.; Gibson, V.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Hargrove, C.K.; Hartmann, C.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herndon, M.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hillier, S.J.; Hobson, P.R.; Hocker, James Andrew; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Joly, A.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Koetke, D.S.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kyberd, P.; Lafferty, G.D.; Lanske, D.; Lauber, J.; Lautenschlager, S.R.; Lawson, I.; Layter, J.G.; Lazic, D.; Lee, A.M.; Lefebvre, E.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mannelli, M.; Marcellini, S.; Markopoulos, C.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menke, S.; Merritt, F.S.; Mes, H.; Meyer, J.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mir, R.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nellen, B.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Oreglia, M.J.; Orito, S.; Palinkas, J.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Polok, J.; Przybycien, M.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharf, F.; Scharff-Hansen, P.; Schieck, J.; Schmitt, B.; Schmitt, S.; Schoning, A.; Schorner, T.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Sittler, A.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Sproston, M.; Stahl, A.; Stephens, K.; Steuerer, J.; Stoll, K.; Strom, David M.; Strohmer, R.; Stumpf, L.; Tafirout, R.; Talbot, S.D.; Tanaka, S.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomson, M.A.; von Torne, E.; Torrence, E.; Towers, S.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turcot, A.S.; Turner-Watson, M.F.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Vikas, P.; Voss, H.; Wackerle, F.; Wagner, A.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Yekutieli, G.; Zacek, V.; Zer-Zion, D.

    1999-01-01

    The branching ratios of the decay of the tau lepton to five charged hadrons have been measured with the OPAL detector at LEP using data collected between 1991 and 1995 at e+e- centre-of-mass energies close to the Z resonance. The branching ratios are measured to be BR(tau- to 3h-2h+nutau) = 0.091+-0.014+-0.005% BR(tau- to 3h-2h+pi0nutau) = 0.027+-0.018+-0.007% where the first error is statistical and the second systematic.

  3. Carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool

    International Nuclear Information System (INIS)

    Cai, Yu; Sha, Shuang

    2016-01-01

    This paper proposes a new carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool used in a cylindrical borehole environment during oil-based mud drilling processes. The new tool is an orthogonal frequency division multiplexing access-based contactless multi-measurand detection tool. The tool can measure formation resistivity in different azimuthal angles and elevational depths. It can measure many more measurands simultaneously in a specified bandwidth than the legacy frequency division multiplexing multi-measurand tool without a channel-select filter while avoiding inter-carrier interference. The paper also shows that formation resistivity is not sensitive to frequency in certain frequency bands. The average resistivity collected from N subcarriers can increase the measurement of the signal-to-noise ratio (SNR) by N times given no amplitude clipping in the current-injection electrode. If the clipping limit is taken into account, with the phase rotation of each single carrier, the amplitude peak-to-average ratio can be reduced by 3 times, and the SNR can achieve a 9/ N times gain over the single-carrier system. The carrier-interleaving technique is also introduced to counter the carrier frequency offset (CFO) effect, where the CFO will cause inter-pad interference. A qualitative analysis and simulations demonstrate that block-interleaving performs better than tone-interleaving when coping with a large CFO. The theoretical analysis also suggests that increasing the subcarrier number can increase the measurement speed or enhance elevational resolution without sacrificing receiver performance. The complex orthogonal multi-pad multi-carrier resistivity logging tool, in which all subcarriers are complex signals, can provide a larger available subcarrier pool than other types of transceivers. (paper)

  4. Estimation of (n,f) Cross-Sections by Measuring Reaction Probability Ratios

    Energy Technology Data Exchange (ETDEWEB)

    Plettner, C; Ai, H; Beausang, C W; Bernstein, L A; Ahle, L; Amro, H; Babilon, M; Burke, J T; Caggiano, J A; Casten, R F; Church, J A; Cooper, J R; Crider, B; Gurdal, G; Heinz, A; McCutchan, E A; Moody, K; Punyon, J A; Qian, J; Ressler, J J; Schiller, A; Williams, E; Younes, W

    2005-04-21

    Neutron-induced reaction cross-sections on unstable nuclei are inherently difficult to measure due to target activity and the low intensity of neutron beams. In an alternative approach, named the 'surrogate' technique, one measures the decay probability of the same compound nucleus produced using a stable beam on a stable target to estimate the neutron-induced reaction cross-section. As an extension of the surrogate method, in this paper they introduce a new technique of measuring the fission probabilities of two different compound nuclei as a ratio, which has the advantage of removing most of the systematic uncertainties. This method was benchmarked in this report by measuring the probability of deuteron-induced fission events in coincidence with protons, and forming the ratio P({sup 236}U(d,pf))/P({sup 238}U(d,pf)), which serves as a surrogate for the known cross-section ratio of {sup 236}U(n,f)/{sup 238}U(n,f). IN addition, the P({sup 238}U(d,d{prime}f))/P({sup 236}U(d,d{prime}f)) ratio as a surrogate for the {sup 237}U(n,f)/{sup 235}U(n,f) cross-section ratio was measured for the first time in an unprecedented range of excitation energies.

  5. Use of compensation assemblies in the first core of SNR-300

    International Nuclear Information System (INIS)

    Billaux, M.; De Wouters, R.; Pilate, S.; Vandenberg, C.

    1975-01-01

    For the SNR-300 reactor, the use of thin fuel pins was limited to the first core. A direct consequence of changing from the cycle reloading scheme to a complete irradiation without refueling operation is an increase of the initial excess reactivity and plutonium investment. The new system of special assemblies conceived to compensate for the too high reactivity of the first core is described: fixed absorbers, made of B 4 C pins, and sodium diluents, consisting simply of hollow wrapper tubes [fr

  6. Main heat transfer components for SNR-300

    International Nuclear Information System (INIS)

    De Haas Van Dorsser, A.H.

    1976-01-01

    Early in the joint German-Belgium-Dutch fast breeder programme it was decided that all main components should be tested, if possible at full scale, before fabrication of the actual SNR-300 components. Descriptions are given of the results of testing, and subsequent modifications, of the pumps, intermediate heat exchangers, and steam generators. A full scale model of the primary pump, free surface vertical shaft centrifugal type, was constructed and tested in the 5000 cubic metres per hour pump test facility erected at Bensberg. A 70 MW model of an intermediate heat exchanger, straight tube type with floating head, was tested in the 50 MW steam generator test station at Hengelo. Also tested in the Hengelo facility was an almost full scale straight tube 50 MW steam generator and subsequently a 50 MW helical tube evaporator. The latter tests were of more than 3000 h operation and resulted in minor changes in design and manufacturing operation. (U.K.)

  7. Fluctuations of the SNR at the output of the MVDR with Regularized Tyler Estimators

    KAUST Repository

    Elkhalil, Khalil

    2016-12-27

    This paper analyzes the statistical properties of the signal-to-noise ratio (SNR) at the output of the Capon\\'s minimum variance distortionless response (MVDR) beamformers when operating over impulsive noises. Particularly, we consider the supervised case in which the receiver employs the regularized Tyler estimator in order to estimate the covariance matrix of the interference-plus-noise process using n observations of size N×1N×1. The choice for the regularized Tylor estimator (RTE) is motivated by its resilience to the presence of outliers and its regularization parameter that guarantees a good conditioning of the covariance estimate. Of particular interest in this paper is the derivation of the second order statistics of the SINR. To achieve this goal, we consider two different approaches. The first one is based on considering the classical regime, referred to as the n-large regime, in which N is assumed to be fixed while n grows to infinity. The second approach is built upon recent results developped within the framework of random matrix theory and assumes that N and n grow large together. Numerical results are provided in order to compare between the accuracies of each regime under different settings.

  8. LATE-TIME EVOLUTION OF COMPOSITE SUPERNOVA REMNANTS: DEEP CHANDRA OBSERVATIONS AND HYDRODYNAMICAL MODELING OF A CRUSHED PULSAR WIND NEBULA IN SNR G327.1-1.1

    Energy Technology Data Exchange (ETDEWEB)

    Temim, Tea [Observational Cosmology Lab, Code 665, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Slane, Patrick [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Kolb, Christopher; Blondin, John [North Carolina State University, 421 Riddick Hall, Raleigh, NC 27695 (United States); Hughes, John P. [Rutgers University, 57 US Highway 1, New Brunswick, NJ 08901 (United States); Bucciantini, Niccoló [INAF Osservatorio Astrofisico di Arcetri, Largo Enrico Fermi, 5, 50125, Firenze Italy (Italy)

    2015-07-20

    In an effort to better understand the evolution of composite supernova remnants (SNRs) and the eventual fate of relativistic particles injected by their pulsars, we present a multifaceted investigation of the interaction between a pulsar wind nebula (PWN) and its host SNR G327.1-1.1. Our 350 Chandra X-ray observations of SNR G327.1-1.1 reveal a highly complex morphology: a cometary structure resembling a bow shock, prong-like features extending into large arcs in the SNR interior, and thermal emission from the SNR shell. Spectral analysis of the non-thermal emission offers clues about the origin of the PWN structures, while enhanced abundances in the PWN region provide evidence for a mixing of supernova ejecta with PWN material. The overall morphology and spectral properties of the SNR suggest that the PWN has undergone an asymmetric interaction with the SNR reverse shock (RS), whichcan occur as a result of a density gradient in the ambient medium and/or a moving pulsar that displaces the PWN from the center of the remnant. We present hydrodynamical simulations of G327.1-1.1 that show that its morphology and evolution can be described by a ∼17,000-year-old composite SNR that expanded into a density gradient with an orientation perpendicular to the pulsar’s motion. We also show that the RS/PWN interaction scenario can reproduce the broadband spectrum of the PWN from radio to γ-ray wavelengths. The analysis and modeling presented in this work have important implications for our general understanding of the structure and evolution of composite SNRs.

  9. Late-Time Evolution of Composite Supernova Remnants: Deep Chandra Observations and Hydrodynamical Modeling of a Crushed Pulsar Wind Nebula in SNR G327.1-1.1

    Science.gov (United States)

    Temim, Tea; Slane, Patrick; Kolb, Christopher; Blondin, John; Hughes, John P.; Bucciantini, Niccolo

    2015-01-01

    In an effort to better understand the evolution of composite supernova remnants (SNRs) and the eventual fate of relativistic particles injected by their pulsars, we present a multifaceted investigation of the interaction between a pulsar wind nebula (PWN) and its host SNR G327.1-1.1. Our 350 ks Chandra X-ray observations of SNR G327.1-1.1 reveal a highly complex morphology; a cometary structure resembling a bow shock, prong-like features extending into large arcs in the SNR interior, and thermal emission from the SNR shell. Spectral analysis of the non-thermal emission offers clues about the origin of the PWN structures, while enhanced abundances in the PWN region provide evidence for mixing of supernova ejecta with PWN material. The overall morphology and spectral properties of the SNR suggest that the PWN has undergone an asymmetric interaction with the SNR reverse shock(RS) that can occur as a result of a density gradient in the ambient medium and or a moving pulsar that displaces the PWN from the center of the remnant. We present hydrodynamical simulations of G327.1-1.1 that show that its morphology and evolution can be described by a approx. 17,000 yr old composite SNR that expanded into a density gradient with an orientation perpendicular to the pulsar's motion. We also show that the RSPWN interaction scenario can reproduce the broadband spectrum of the PWN from radio to gamma-ray wavelengths. The analysis and modeling presented in this work have important implications for our general understanding of the structure and evolution of composite SNRs.

  10. Nuclear Power Station Kalkar, 300 MWe Prototype Nuclear Power Plant with Fast Sodium Cooled Reactor (SNR-300), Plant description

    International Nuclear Information System (INIS)

    1984-06-01

    The nuclear power station Kalkar (SNR-300) is a prototype with a sodium cooled fast reactor and a thermal power of 762 MW. The present plant description has been made available in parallel to the licensing procedure for the reactor plant and its core Mark-Ia as supplementary information for the public. The report gives a detailed description of the whole plant including the prevention measures against the impact of external and plant internal events. The radioactive materials within the reactor cooling system and the irradiation protection and surveillance measures are outlined. Finally, the operation of the plant is described with the start-up procedures, power operation, shutdown phases with decay heat removal and handling procedures

  11. Improvement of stress tolerance and leavening ability under multiple baking-associated stress conditions by overexpression of the SNR84 gene in baker's yeast.

    Science.gov (United States)

    Lin, Xue; Zhang, Cui-Ying; Bai, Xiao-Wen; Feng, Bing; Xiao, Dong-Guang

    2015-03-16

    During the bread-making process, industrial baker's yeast cells are exposed to multiple baking-associated stresses, such as elevated high-temperature, high-sucrose and freeze-thaw stresses. There is a high demand for baker's yeast strains that could withstand these stresses with high leavening ability. The SNR84 gene encodes H/ACA snoRNA (small nucleolar RNA), which is known to be involved in pseudouridylation of the large subunit rRNA. However, the function of the SNR84 gene in baker's yeast coping with baking-associated stresses remains unclear. In this study, we explored the effect of SNR84 overexpression on baker's yeast which was exposed to high-temperature, high-sucrose and freeze-thaw stresses. These results suggest that overexpression of the SNR84 gene conferred tolerance of baker's yeast cells to high-temperature, high-sucrose and freeze-thaw stresses and enhanced their leavening ability in high-sucrose and freeze-thaw dough. These findings could provide a valuable insight for breeding of novel stress-resistant baker's yeast strains that are useful for baking. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Real-time photonic sampling with improved signal-to-noise and distortion ratio using polarization-dependent modulators

    Science.gov (United States)

    Liang, Dong; Zhang, Zhiyao; Liu, Yong; Li, Xiaojun; Jiang, Wei; Tan, Qinggui

    2018-04-01

    A real-time photonic sampling structure with effective nonlinearity suppression and excellent signal-to-noise ratio (SNR) performance is proposed. The key points of this scheme are the polarization-dependent modulators (P-DMZMs) and the sagnac loop structure. Thanks to the polarization sensitive characteristic of P-DMZMs, the differences between transfer functions of the fundamental signal and the distortion become visible. Meanwhile, the selection of specific biases in P-DMZMs is helpful to achieve a preferable linearized performance with a low noise level for real-time photonic sampling. Compared with the quadrature-biased scheme, the proposed scheme is capable of valid nonlinearity suppression and is able to provide a better SNR performance even in a large frequency range. The proposed scheme is proved to be effective and easily implemented for real time photonic applications.

  13. [Comparison study on subjective and objective measurements of the accommodative convergence to accommodation ratio].

    Science.gov (United States)

    Xu, Jing-jing; Xu, Dan; Huang, Tao; Jiang, Jian; Lü, Fan

    2012-05-01

    To detect the accommodative convergence to accommodation (AC/A) ratios measured respectively by objective and subjective methods. The differences and its relative factors were explored. Forty young volunteers were measured by eye tracker to get the amount of convergence when fixating at the target at 100 cm, 50 cm, 33 cm and 25 cm and were measured by infrared auto-refractor to get corresponding accommodative responses. AC/A ratio based on these two measurements were compared with the calculated and the gradient AC/A ratio from Von Graefe tests. Mean value of stimulated AC/A ratio measured by eye tracker was higher than the calculated and gradient AC/A ratio by Von Graefe method (P = 0.003, 0.001). There are statistic correlation (r = 0.871, P = 0.000) and difference (P = 0.000) between stimulated AC/A ratio and response AC/A ratios both measured by eye tracker, and the difference trends to be greater with the higher AC/A ratio. The objective AC/A ratio is usually higher than the clinical subjective measurement because of more proximal effect. The response AC/A ratio measured objectively may reveal realistically the mutual effect and relationship between accommodation and convergence and it seems to be more credible to be the monitor parameter on progression of myopia in clinics.

  14. A Time-Measurement System Based on Isotopic Ratios

    International Nuclear Information System (INIS)

    Vo, Duc T.; Karpius, P.J.; MacArthur, D.W.; Thron, J.L.

    2007-01-01

    A time-measurement system can be built based on the ratio of gamma-ray peak intensities from two radioactive isotopes. The ideal system would use a parent isotope with a short half-life decaying to a long half-life daughter. The activities of the parent-daughter isotopes would be measured using a gamma-ray detector system. The time can then be determined from the ratio of the activities. The best-known candidate for such a system is the 241 Pu- 241 Am parent-daughter pair. However, this 241 Pu- 241 Am system would require a high-purity germanium detector system and sophisticated software to separate and distinguish between the many gamma-ray peaks produced by the decays of the two isotopes. An alternate system would use two different isotopes, again one with a short half-life and one with a half-life that is long relative to the other. The pair of isotopes 210 Pb and 241 Am (with half-lives of 22 and 432 years, respectively) appears suitable for such a system. This time-measurement system operates by measuring the change in the ratio of the 47-keV peak of 210 Pb to the 60-keV peak of 241 Am. For the system to work reasonably well, the resolution of the detector would need to be such that the two gamma-ray peaks are well separated so that their peak areas can be accurately determined using a simple region-of-interest (ROI) method. A variety of detectors were tested to find a suitable system for this application. The results of these tests are presented here.

  15. The prospect for fuel ion ratio measurements in ITER by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Korsholm, Søren Bang; Nielsen, Stefan Kragh

    2012-01-01

    We show that collective Thomson scattering (CTS) holds the potential to become a new diagnostic principle for measurements of the fuel ion ratio, nT/nD, in ITER. Fuel ion ratio measurements will be important for plasma control and machine protection in ITER. Measurements of ion cyclotron structures...... in CTS spectra have been suggested as the basis for a new fuel ion ratio diagnostic which would be well suited for reactor environments and capable of providing spatially resolved measurements in the plasma core. Such measurements were demonstrated in recent experiments in the TEXTOR tokamak. Here we...... conduct a sensitivity study to investigate the potential measurement accuracy of a CTS fuel ion ratio diagnostic on ITER. The study identifies regions of parameter space in which CTS can be expected to provide useful information on plasma composition, and we find that a CTS fuel ion ratio diagnostic could...

  16. Measurement of stable isotope ratio of organic carbon in water samples

    International Nuclear Information System (INIS)

    Fujii, Toshihiro; Otsuki, Akira

    1977-01-01

    A new method for the measurement of stable isotope ratios was investigated and applied to organic carbon's isotope ratio measurements in water samples. A few river water samples from Tsuchiura city were tested. After the wet oxidation of organic carbons to carbon dioxide in a sealed ampoule, the isotope ratios were determined with the gas chromatograph-quadrupole mass spectrometer combined with a total organic carbon analyser, under the dynamic conditions. The GC-MS had been equipped with the multiple ion detector-digital integrator system. The ion intensities at m/e 44 and 45 were simultaneously measured at a switching rate of 1 ms. The measurements with carbon dioxide acquired from sodium carbonate (53 μg) gave the isotope ratios with the variation coefficient of 0.62%. However, the variation coefficients obtained from organic carbons in natural water samples were 2 to 3 times as high as that from sodium carbonate. This method is simple and rapid and may be applied to various fields especially in biology and medicine. (auth.)

  17. A relationship between SNR G109.1-1.0 and the molecular cloud of Sh2-152

    International Nuclear Information System (INIS)

    Heydari-Malayeri, M.; Kahane, C.; Lucas, R.

    1981-01-01

    The possible association of the supernova remnant SNR G109.1 - 1.0 and the x-ray source GF2259 + 586 with the molecular cloud of Sh2 - 152 has been investigated by observing the molecular line 13 CO (J = 1 → 0) of the complex Sh2 - 147/Sh2 - 153. The present results are compared with those of previous workers. It is shown that although the various estimates of distance for the SNR, the x-ray source, the H II region Sh2 - 152 and the molecular cloud are in relatively good agreement, because of the uncertainties of distance evaluation in the Perseus arm this cannot be regarded as conclusive proof of the association of these objects. (U.K.)

  18. Measurement of the atmospheric muon charge ratio with the OPERA detector

    CERN Document Server

    Agafonova, N.; Aoki, S.; Ariga, A.; Ariga, T.; Autiero, D.; Badertscher, A.; Bagulya, A.; Bertolin, A.; Besnier, M.; Bick, D.; Boyarkin, V.; Bozza, C.; Brugiere, T.; Brugnera, R.; Brunetti, G.; Buontempo, S.; Cazes, A.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chon-Sen, N.; Chukanov, A.; Cozzi, M.; D'Amato, G.; Dal Corso, F.; D'Ambrosio, N.; De Lellis, G.; Declais, Y.; De Serio, M.; Di Capua, F.; Di Ferdinando, D.; Di Giovanni, A.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Ebert, J.; Egorov, O.; Enikeev, R.; Ereditato, A.; Esposito, L.S.; Favier, J.; Felici, G.; Ferber, T.; Fini, R.; Frekers, D.; Fukuda, T.; Fukushima, C.; Galkin, V.I.; Garfagnini, A.; Giacomelli, G.; Giorgini, M.; Goellnitz, C.; Goldberg, J.; Golubkov, D.; Goncharova, L.; Gornushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gustavino, C.; Hagner, C.; Hamada, K.; Hara, T.; Hierholzer, M.; Hoshino, K.; Ieva, M.; Jakovcic, K.; Jollet, C.; Juget, F.; Kazuyama, M.; Kim, S.H.; Kimura, M.; Klicek, B.; Knuesel, J.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Kubota, H.; Lazzaro, C.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Lutter, G.; Malgin, A.; Mandrioli, G.; Marotta, A.; Marteau, J.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meisel, F.; Meregaglia, A.; Migliozzi, P.; Mikado, S.; Miyamoto, S.; Monacelli, P.; Morishima, K.; Moser, U.; Muciaccia, M.T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Naumov, D.; Nikitina, V.; Niwa, K.; Nonoyama, Y.; Ogawa, S.; Olchevski, A.; Oldorf, C.; Orlova, G.; Osedlo, V.; Paniccia, M.; Paoloni, A.; Park, B.D.; Park, I.G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pilipenko, V.; Pistillo, C.; Policastro, G.; Polukhina, N.; Pozzato, M.; Pretzl, K.; Publichenko, P.; Pupilli, F.; Rescigno, R.; Roganova, T.; Rokujo, H.; Romano, G.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Russo, A.; Ryasny, V.; Ryazhskaya, O.; Sato, O.; Sato, Y.; Schembri, A.; Schmidt Parzefall, W.; Schroeder, H.; Scotto Lavina, L.; Sheshukov, A.; Shibuya, H.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Song, J.S.; Spinetti, M.; Stanco, L.; Starkov, N.; Stipcevic, M.; Strauss, T.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tezuka, I.; Tioukov, V.; Tolun, P.; Tran, T.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J.L.; Wilquet, G.; Wonsak, B.; Yakushev, V.; Yoon, C.S.; Yoshioka, T.; Yoshida, J.; Zaitsev, Y.; Zemskova, S.; Zghiche, A.; Zimmermann, R.

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the charge ratio dependence on the primary composition. The measured charge ratio values were corrected taking into account the charge-misidentification errors. Data have also been grouped in five bins of the "vertical surface energy". A fit to a simplified model of muon production in the atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  19. Experimental investigations on scaled models for the SNR-2 decay heat removal by natural convection

    International Nuclear Information System (INIS)

    Hoffmann, H.; Weinberg, D.; Tschoeke, H.; Frey, H.H.; Pertmer, G.

    1986-01-01

    Scaled water models are used to prove the mode of function of the decay heat removal by natural convection for the SNR-2. The 2D and 3D models were designed to reach the characteristic numbers (Richardson, Peclet) of the reactor. In the experiments on 2D models the position of the immersed cooler (IC) and the power were varied. Temperature fields and velocities were measured. The IC installed as a separate component in the hot plenum resulted in a very complex flow behavior and low temperatures. Integrating the IC in the IHX showed a very simple circulating flow and high temperatures within the hot plenum. With increasing power only slightly rising temperature differences within the core and IC were detected. Recalculations using the COMMIX 1B code gave qualitatively satisfying results. (author)

  20. Development, optimisation, and application of ICP-SFMS methods for the measurement of isotope ratios

    International Nuclear Information System (INIS)

    Stuerup, S.

    2000-07-01

    The measurement of isotopic composition and isotope ratios in biological and environmental samples requires sensitive, precise, and accurate analytical techniques. The analytical techniques used are traditionally based on mass spectrometry, among these techniques is the ICP-SFMS technique, which became commercially available in the mid 1990s. This technique is characterised by high sensitivity, low background, and the ability to separate analyte signals from spectral interferences. These features are beneficial for the measurement of isotope ratios and enable the measurement of isotope ratios of elements, which it has not previously been possible to measure due to either spectral interferences or poor sensitivity. The overall purpose of the project was to investigate the potential of the single detector ICP-SFMS technique for the measurement of isotope ratios in biological and environmental samples. One part of the work has focused on the fundamental aspects of the ICP-SFMS technique with special emphasize on the features important to the measurement of isotope ratios, while another part has focused on the development, optimisation and application of specific methods for the measurement of isotope ratios of elements of nutritional interest and radionuclides. The fundamental aspects of the ICP-SFMS technique were investigated theoretically and experimentally by the measurement of isotope ratios applying different experimental conditions. It was demonstrated that isotope ratios could be measured reliably using ICP-SFMS by educated choice of acquisition parameters, scanning mode, mass discrimination correction, and by eliminating the influence of detector dead time. Applying the knowledge gained through the fundamental study, ICP-SFMS methods for the measurement of isotope ratios of calcium, zinc, molybdenum and iron in human samples and a method for the measurement of plutonium isotope ratios and ultratrace levels of plutonium and neptunium in environmental samples

  1. Concepts on high temperature design analysis for SNR 300

    International Nuclear Information System (INIS)

    Bieniussa, K.; Zolti, E.

    1976-01-01

    The paper briefly describes the evolution, the present situation and the next activities on the design of high temperature components of the DEBENELUX prototype fast breeder reactor SNR-300 with particular regard to the design criteria. Elastic structural analyses are performed for the basic design of the components and are supplied by the manufacturer. In agreement with the Safety Experts simplified and/or detailed inelastic analyses of the critical areas are supplied by the prime contractor of the plant. The elastic computations are evaluated on the basis of a set of design rules derived from ASME Code Case Interpretation 1331-4 but with more conservative limits, and the inelastic ones on the basis of the ASME Code Case Interpretation 1592

  2. Measurement of the anisotropy ratios in MgB2 single crystals

    International Nuclear Information System (INIS)

    Kim, Heon-Jung; Kang, Byeongwon; Lee, Hyun-Sook; Lee, Sung-Ik

    2006-01-01

    We present our recent measurements on the anisotropy ratios of MgB 2 single crystals. Our measurements indicate that the anisotropy ratios of the penetration depth and of the upper critical field have different magnitudes and temperature dependences, as predicted by theoretical calculations. These results imply that the two-gap nature can strongly influence the superconducting properties of MgB 2

  3. Throughput Estimation Method in Burst ACK Scheme for Optimizing Frame Size and Burst Frame Number Appropriate to SNR-Related Error Rate

    Science.gov (United States)

    Ohteru, Shoko; Kishine, Keiji

    The Burst ACK scheme enhances effective throughput by reducing ACK overhead when a transmitter sends sequentially multiple data frames to a destination. IEEE 802.11e is one such example. The size of the data frame body and the number of burst data frames are important burst transmission parameters that affect throughput. The larger the burst transmission parameters are, the better the throughput under error-free conditions becomes. However, large data frame could reduce throughput under error-prone conditions caused by signal-to-noise ratio (SNR) deterioration. If the throughput can be calculated from the burst transmission parameters and error rate, the appropriate ranges of the burst transmission parameters could be narrowed down, and the necessary buffer size for storing transmit data or received data temporarily could be estimated. In this paper, we present a method that features a simple algorithm for estimating the effective throughput from the burst transmission parameters and error rate. The calculated throughput values agree well with the measured ones for actual wireless boards based on the IEEE 802.11-based original MAC protocol. We also calculate throughput values for larger values of the burst transmission parameters outside the assignable values of the wireless boards and find the appropriate values of the burst transmission parameters.

  4. Nature of the Diffuse Source and Its Central Point-like Source in SNR 0509–67.5

    Energy Technology Data Exchange (ETDEWEB)

    Litke, Katrina C.; Chu, You-Hua; Holmes, Abigail; Santucci, Robert; Blindauer, Terrence; Gruendl, Robert A.; Ricker, Paul M. [Astronomy Department, University of Illinois, 1002 W. Green Street, Urbana, IL 61801 (United States); Li, Chuan-Jui [Academia Sinica Institute of Astronomy and Astrophysics, P.O. Box 23-141, Taipei 10617, Taiwan, R.O.C. (China); Pan, Kuo-Chuan [Departement Physik, Universität Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Weisz, Daniel R., E-mail: kclitke@email.arizona.edu [Department of Astronomy, University of California, 501 Cambell Hall #3411, Berkeley, CA 94720-3411 (United States)

    2017-03-10

    We examine a diffuse emission region near the center of SNR 0509−67.5 to determine its nature. Within this diffuse region we observe a point-like source that is bright in the near-IR, but is not visible in the B and V bands. We consider an emission line observed at 6766 Å and the possibilities that it is Ly α , H α , and [O ii] λ 3727. We examine the spectral energy distribution (SED) of the source, comprised of Hubble Space Telescope B , V , I , J , and H bands in addition to Spitzer /IRAC 3.6, 4.5, 5.8, and 8 μ m bands. The peak of the SED is consistent with a background galaxy at z ≈ 0.8 ± 0.2 and a possible Balmer jump places the galaxy at z ≈ 0.9 ± 0.3. These SED considerations support the emission line’s identification as [O ii] λ 3727. We conclude that the diffuse source in SNR 0509−67.5 is a background galaxy at z ≈ 0.82. Furthermore, we identify the point-like source superposed near the center of the galaxy as its central bulge. Finally, we find no evidence for a surviving companion star, indicating a double-degenerate origin for SNR 0509−67.5.

  5. Nature of the Diffuse Source and Its Central Point-like Source in SNR 0509–67.5

    International Nuclear Information System (INIS)

    Litke, Katrina C.; Chu, You-Hua; Holmes, Abigail; Santucci, Robert; Blindauer, Terrence; Gruendl, Robert A.; Ricker, Paul M.; Li, Chuan-Jui; Pan, Kuo-Chuan; Weisz, Daniel R.

    2017-01-01

    We examine a diffuse emission region near the center of SNR 0509−67.5 to determine its nature. Within this diffuse region we observe a point-like source that is bright in the near-IR, but is not visible in the B and V bands. We consider an emission line observed at 6766 Å and the possibilities that it is Ly α , H α , and [O ii] λ 3727. We examine the spectral energy distribution (SED) of the source, comprised of Hubble Space Telescope B , V , I , J , and H bands in addition to Spitzer /IRAC 3.6, 4.5, 5.8, and 8 μ m bands. The peak of the SED is consistent with a background galaxy at z ≈ 0.8 ± 0.2 and a possible Balmer jump places the galaxy at z ≈ 0.9 ± 0.3. These SED considerations support the emission line’s identification as [O ii] λ 3727. We conclude that the diffuse source in SNR 0509−67.5 is a background galaxy at z ≈ 0.82. Furthermore, we identify the point-like source superposed near the center of the galaxy as its central bulge. Finally, we find no evidence for a surviving companion star, indicating a double-degenerate origin for SNR 0509−67.5.

  6. Measurement of Poisson's ratio of nonmetallic materials by laser holographic interferometry

    Science.gov (United States)

    Zhu, Jian T.

    1991-12-01

    By means of the off-axis collimated plane wave coherent light arrangement and a loading device by pure bending, Poisson's ratio values of CFRP (carbon fiber-reinforced plactics plates, lay-up 0 degree(s), 90 degree(s)), GFRP (glass fiber-reinforced plactics plates, radial direction) and PMMA (polymethyl methacrylate, x, y direction) have been measured. In virtue of this study, the ministry standard for the Ministry of Aeronautical Industry (Testing method for the measurement of Poisson's ratio of non-metallic by laser holographic interferometry) has been published. The measurement process is fast and simple. The measuring results are reliable and accurate.

  7. Signal-to-noise ratio, T2 , and T2* for hyperpolarized helium-3 MRI of the human lung at three magnetic field strengths.

    Science.gov (United States)

    Komlosi, Peter; Altes, Talissa A; Qing, Kun; Mooney, Karen E; Miller, G Wilson; Mata, Jaime F; de Lange, Eduard E; Tobias, William A; Cates, Gordon D; Mugler, John P

    2017-10-01

    To evaluate T 2 , T2*, and signal-to-noise ratio (SNR) for hyperpolarized helium-3 ( 3 He) MRI of the human lung at three magnetic field strengths ranging from 0.43T to 1.5T. Sixteen healthy volunteers were imaged using a commercial whole body scanner at 0.43T, 0.79T, and 1.5T. Whole-lung T 2 values were calculated from a Carr-Purcell-Meiboom-Gill spin-echo-train acquisition. T2* maps and SNR were determined from dual-echo and single-echo gradient-echo images, respectively. Mean whole-lung SNR values were normalized by ventilated lung volume and administered 3 He dose. As expected, T 2 and T2* values demonstrated a significant inverse relationship to field strength. Hyperpolarized 3 He images acquired at all three field strengths had comparable SNR values and thus appeared visually very similar. Nonetheless, the relatively small SNR differences among field strengths were statistically significant. Hyperpolarized 3 He images of the human lung with similar image quality were obtained at three field strengths ranging from 0.43T and 1.5T. The decrease in susceptibility effects at lower fields that are reflected in longer T 2 and T2* values may be advantageous for optimizing pulse sequences inherently sensitive to such effects. The three-fold increase in T2* at lower field strength would allow lower receiver bandwidths, providing a concomitant decrease in noise and relative increase in SNR. Magn Reson Med 78:1458-1463, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Measurement of a Cosmographic Distance Ratio with Galaxy and Cosmic Microwave Background Lensing.

    Science.gov (United States)

    Miyatake, Hironao; Madhavacheril, Mathew S; Sehgal, Neelima; Slosar, Anže; Spergel, David N; Sherwin, Blake; van Engelen, Alexander

    2017-04-21

    We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z∼1 (background galaxies) and at the surface of last scattering at z∼1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in the ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r=0.390_{-0.062}^{+0.070}, at an effective redshift of z=0.53. This is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r=0.419.

  9. Ultrasonic attenuation measurements at very high SNR: Correlation, information theory and performance

    International Nuclear Information System (INIS)

    Challis, Richard; Ivchenko, Vladimir; Al-Lashi, Raied

    2013-01-01

    This paper describes a system for ultrasonic wave attenuation measurements which is based on pseudo-random binary codes as transmission signals combined with on-the-fly correlation for received signal detection. The apparatus can receive signals in the nanovolt range against a noise background in the order of hundreds of microvolts and an analogue to digital convertor (ADC) bit-step also in the order of hundreds of microvolts. Very high signal to noise ratios (SNRs) are achieved without recourse to coherent averaging with its associated requirement for high sampling times. The system works by a process of dithering – in which very low amplitude received signals enter the dynamic range of the ADC by 'riding' on electronic noise at the system input. The amplitude of this 'useful noise' has to be chosen with care for an optimised design. The process of optimisation is explained on the basis of classical information theory and is achieved through a simple noise model. The performance of the system is examined for different transmitted code lengths and gain settings in the receiver chain. Experimental results are shown to verify the expected operation when the system is applied to a very highly attenuating material – an aerated slurry

  10. Radiographic measurement of the cardiothoracic ratio in pet macaques from Sulawesi, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Michael A. [Department of Social Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4 (Canada)], E-mail: schillaci@utsc.utoronto.ca; Parish, Stephanie [Department of Social Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4 (Canada); Jones-Engel, Lisa [National Primate Research Center, University of Washington, 1705 N.E. Pacific Street, Seattle, WA 98195 (United States)

    2009-11-15

    The relative size of the heart, as measured by the cardiothoracic ratio, is often used as an index of ventricular hypertrophy-an important measure of myocardial pathophysiology in human primates. Despite its widespread use in human medicine, use of the cardiothoracic ratio in nonhuman primate veterinary medicine has been poorly documented. This report describes the results of our radiographic study of the cardiothoracic ratio in a sample of pet monkeys from Sulawesi, Indonesia. We assessed the effects of age and sex on cardiothoracic ratios, and compared our estimates with those presented in the literature for the Formosan macaque (Macaca cyclopis). Our results indicated a significant difference between the Sulawesi macaque species groupings in cardiothoracic ratios. Sex and age-related differences were not significant. Comparisons of cardiothoracic ratios with published ratios indicated similarity between M. cyclopis and Macaca nigra, but not between M. cyclopis and Macaca tonkeana.

  11. Radiographic measurement of the cardiothoracic ratio in pet macaques from Sulawesi, Indonesia

    International Nuclear Information System (INIS)

    Schillaci, Michael A.; Parish, Stephanie; Jones-Engel, Lisa

    2009-01-01

    The relative size of the heart, as measured by the cardiothoracic ratio, is often used as an index of ventricular hypertrophy-an important measure of myocardial pathophysiology in human primates. Despite its widespread use in human medicine, use of the cardiothoracic ratio in nonhuman primate veterinary medicine has been poorly documented. This report describes the results of our radiographic study of the cardiothoracic ratio in a sample of pet monkeys from Sulawesi, Indonesia. We assessed the effects of age and sex on cardiothoracic ratios, and compared our estimates with those presented in the literature for the Formosan macaque (Macaca cyclopis). Our results indicated a significant difference between the Sulawesi macaque species groupings in cardiothoracic ratios. Sex and age-related differences were not significant. Comparisons of cardiothoracic ratios with published ratios indicated similarity between M. cyclopis and Macaca nigra, but not between M. cyclopis and Macaca tonkeana.

  12. Impact of time-domain IP pulse length on measured data and inverted models

    DEFF Research Database (Denmark)

    Olsson, P. I.; Fiandaca, G.; Dahlin, T.

    2015-01-01

    The duration of time domain (TD) induced polarization (IP) current injections has significant impact on the acquired IP data as well as on the inversion models, if the standard evaluation procedure is followed. However, it is still possible to retrieve similar inversion models if the waveform...... of the injected current and the IP response waveform are included in the inversion. The on-time also generally affects the signal-tonoise ratio (SNR) where an increased on-time gives higher SNR for the IP data....

  13. Effect of heterophoria measurement technique on the clinical accommodative convergence to accommodation ratio.

    Science.gov (United States)

    Escalante, Jaime Bernal; Rosenfield, Mark

    2006-05-01

    Measurement of the stimulus accommodative convergence to accommodation (AC/A) ratio is a standard procedure in clinical optometric practice. Typically, heterophoria is assessed at several accommodative stimulus levels, and the gradient of the vergence to accommodation function computed. A number of procedures are available for the subjective measurement of heterophoria, but it is unclear whether the use of different vergence measurement techniques will alter the obtained AC/A value. Accordingly, the current study compared AC/A ratios measured using 3 clinical subjective heterophoria tests, namely the von Graefe (VG), Maddox Rod (MR), and Modified Thorington (MT) procedures. The AC/A ratio was measured in 60 visually normal subjects between 20 and 25 years of age using each of the 3 procedures listed above. The accommodative stimulus was varied by the introduction of +/-1.00 diopter (D) spherical lenses over the distance refractive correction while subjects viewed a target at a viewing distance of 40 cm. To examine the repeatability of each procedure, the AC/A ratio was measured on 2 separate occasions for each measurement technique, with the 2 sessions being separated by at least 24 hours. Mean values of stimulus AC/A ratio measured using the VG, MR, and MT procedures were 3.47, 2.99, and 2.46Delta/D, respectively. These differences were significant (p=0.0001). In addition, the coefficient of repeatability for the 3 techniques was 2.22, 1.99, and 1.20 Delta/D, respectively. Ratios obtained using the Modified Thorington technique with +/-1.00 D lenses showed the best repeatability, whereas the poorest repeatability was found with the von Graefe technique when only +1.00 D lenses were used to vary the accommodative stimulus. Accordingly, we recommend that that Modified Thorington procedure with +/-1.00 D lenses be used to quantify heterophoria during clinical measurement of the stimulus AC/A ratio.

  14. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

    Science.gov (United States)

    Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon

    2015-05-01

    The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  15. Measurement of the charge ratio of atmospheric muons with the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Khachatryan, Vardan [Yerevan Physics Inst. (Armenia); et al.

    2010-08-01

    We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 \\pm 0.0032(stat.) \\pm 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments.

  16. Development, design, construction and testing of pumps, intermediate heat exchangers and manipulator systems for in-service inspection of SNR 300

    International Nuclear Information System (INIS)

    Vroom, J.P.; Heslenfeld, M.W.; Westerweele, W.J.; Willigen, A. van

    1978-01-01

    The first part of this paper reviews the development, design, construction and testing of sodium pumps and intermediate heat exchangers as carried out by NERATOOM in the Netherlands. Testing of full-size components under operational conditions yielded important information for the design of the components for SNR 300. Information is also given in brief on the manufacture of the components. The second part reviews the work done on manipulator systems for in-service inspection as carried out by INTERATOM in Germany. In this field again experience gained from tests had important consequences for the design of the apparatus for SNR 300. (author)

  17. Design Report for the core design of the first core Mark-Ia of the SNR-300

    International Nuclear Information System (INIS)

    Stanculescu, A.

    1984-05-01

    The report describes the first core Mark-Ia of the SNR-300 reactor and its different assembly types with their operational strategy. Methods, criteria and results of the neutron physical, thermal hydraulic and core mechanical design of the whole core and its assemblies are presented

  18. Risk-oriented analysis of the German prototype fast breeder reactor SNR-300: off-site accident consequence model and results of the study

    International Nuclear Information System (INIS)

    Bayer, A.; Ehrhardt, J.

    1984-01-01

    Accident off-site consequence calculations and risk assessments performed for the ''risk oriented analysis'' of the German prototype fast breeder reactor SNR-300 were performed with a modified version of the off-site accident consequence model UFOMOD. The modifications mainly relate to the deposition and resuspension processes, the ingestion model, and the dose factors. Consequence calculations at the site of Kalkar on the Rhine River were performed for 115 weather sequences in 36 wind directions. They were based on seven release categories evaluated for the SNR-300 with two different fueling strategies: plutonium from Magnox reactors only and plutonium from light water reactors and Magnox reactors. In parallel, the corresponding frequencies of occurrence are determined. The following results are generated: 1. complementary cumulative frequency distribution functions for collective fatalities and collective doses 2. expected values of the collective fatalities and collective doses as well as distance-dependent expected values of individual fatality 3. contributions of the different exposure pathways to fatalities with respect to the various organs. For comparison with the risk of a PWR-1300, calculations for the PWR-1300 of the ''German Risk Study'' were repeated with the same modified consequence model. Comparison shows that smaller risks result for the SNR-300. However, the confidence interval bandwidths obtained for the frequencies of the release categories for the SNR-300 are larger than those of the PWR-1300

  19. Status of sodium removal and component decontamination technology in the SNR programme

    Energy Technology Data Exchange (ETDEWEB)

    Haubold, W [INTERATOM GmbH, Bergisch Gladbach (Germany); Smit, C Ch [MT-TNO Dept. 50-MW Sodium Component Test Facility, Hengelo (Netherlands); Stade, K Ch [Kernkraftwerk-Betriebsgesellschaft mbH, Eggenstein-Leopoldshafen (Germany)

    1978-08-01

    This paper summarizes the experience with sodium removal and component decontamination processes within the framework of the SNR project since the IAEA Specialists Meeting on 'Decontamination of Plant Components from Sodium and Radioactivity' at Dounreay, April 9-12, 1973. The moist nitrogen process has been successfully applied to remove sodium from all 66 fuel elements of the KNK I core. Progress has been obtained in removing sodium from fuel elements and large components by vacuum distillation. Areas where future development is required are identified. (author)

  20. Status of sodium removal and component decontamination technology in the SNR programme

    International Nuclear Information System (INIS)

    Haubold, W.; Smit, C.Ch.; Stade, K.Ch.

    1978-01-01

    This paper summarizes the experience with sodium removal and component decontamination processes within the framework of the SNR project since the IAEA Specialists Meeting on 'Decontamination of Plant Components from Sodium and Radioactivity' at Dounreay, April 9-12, 1973. The moist nitrogen process has been successfully applied to remove sodium from all 66 fuel elements of the KNK I core. Progress has been obtained in removing sodium from fuel elements and large components by vacuum distillation. Areas where future development is required are identified. (author)

  1. Off-gas filter system of the SNR-300

    International Nuclear Information System (INIS)

    Boehm, L.; Jordan, S.; Schikarski, W.

    1975-01-01

    The Reventing-Exventing-System of the German Liquid Metal Fast Breeder Prototype SNR-300 is described. After an accident with major damage to the core the ventilation valves are quickly closed. At the same time the blower of the reventing system evacuates the reventing gap up to a pressure difference of 2 mbar between the containment and the outer atmosphere. This pressure difference prevents a leakage from the containment to the outside. The revented gas is recirculated into the outer-containment. Leaks from the atmosphere and possibly from the inner containment into the reventing gap increase the pressure in the outer-containment. Therefore depending on the pressure build-up which is determined by the course of the accident, it is necessary to exvent the containment after several days. The exvented gas is filtered by a filter combination consisting of pre-filters, charcoal-filters and HEPA-filters. Because accidental sodium fires produce high concentrations of sodium oxide-aerosols this filter system must resist chemical aggressive aerosols. (U.S.)

  2. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

    Directory of Open Access Journals (Sweden)

    Pil-Jong Kim

    2015-05-01

    Full Text Available Objectives The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL. Materials and Methods The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  3. Measurement of the charge ratio of atmospheric muons with the CMS detector

    CERN Document Server

    AUTHOR|(CDS)2070976

    2010-01-01

    5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 $\\pm$ 0.0032 (stat.) $\\pm$ 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic-ray shower models and compatible with previous measurements by deep-underground experiments.

  4. Adaptive digital fringe projection technique for high dynamic range three-dimensional shape measurement.

    Science.gov (United States)

    Lin, Hui; Gao, Jian; Mei, Qing; He, Yunbo; Liu, Junxiu; Wang, Xingjin

    2016-04-04

    It is a challenge for any optical method to measure objects with a large range of reflectivity variation across the surface. Image saturation results in incorrect intensities in captured fringe pattern images, leading to phase and measurement errors. This paper presents a new adaptive digital fringe projection technique which avoids image saturation and has a high signal to noise ratio (SNR) in the three-dimensional (3-D) shape measurement of objects that has a large range of reflectivity variation across the surface. Compared to previous high dynamic range 3-D scan methods using many exposures and fringe pattern projections, which consumes a lot of time, the proposed technique uses only two preliminary steps of fringe pattern projection and image capture to generate the adapted fringe patterns, by adaptively adjusting the pixel-wise intensity of the projected fringe patterns based on the saturated pixels in the captured images of the surface being measured. For the bright regions due to high surface reflectivity and high illumination by the ambient light and surfaces interreflections, the projected intensity is reduced just to be low enough to avoid image saturation. Simultaneously, the maximum intensity of 255 is used for those dark regions with low surface reflectivity to maintain high SNR. Our experiments demonstrate that the proposed technique can achieve higher 3-D measurement accuracy across a surface with a large range of reflectivity variation.

  5. Physical evaluation of prototype high-performance anti-scatter grids: potential for improved digital radiographic image quality

    International Nuclear Information System (INIS)

    Fetterly, Kenneth A; Schueler, Beth A

    2009-01-01

    Grid evaluation for a screen-film x-ray system has typically included independent measurement of the opposing contrast improvement factor and Bucky factor. Neither of these metrics, however, is appropriate when assessing grid performance in a digital imaging environment. For digital radiographic systems, the benefit of an anti-scatter grid is well characterized by the quantum signal-to-noise ratio improvement factor (K SNR ) provided by the grid. The purpose of this work was to measure K SNR of prototype grids designed for use with digital radiographic systems. The prototype grids had 5 mm tall lead septa, fiber interspace material, line rate N = 25 and 36 cm -1 and ratio r = 15 and 21, respectively. The primary and scatter transmission properties of the grids were measured, and K SNR was evaluated over a phantom thickness range of 10-50 cm. To provide a comparison, the K SNR of similarly constructed N44r15 and N80r15 grids is also reported. K SNR of the prototype grids ranged from 1.4 for the 10 cm phantom to 2.4 for the 50 cm phantom. For the thickest phantom, the SNR improvement factor of the prototype grids was 18-83% higher than that of the N44r15 and N80r15 grids, respectively. (note)

  6. Low noise signal-to-noise ratio enhancing readout circuit for current-mediated active pixel sensors

    International Nuclear Information System (INIS)

    Ottaviani, Tony; Karim, Karim S.; Nathan, Arokia; Rowlands, John A.

    2006-01-01

    Diagnostic digital fluoroscopic applications continuously expose patients to low doses of x-ray radiation, posing a challenge to both the digital imaging pixel and readout electronics when amplifying small signal x-ray inputs. Traditional switch-based amorphous silicon imaging solutions, for instance, have produced poor signal-to-noise ratios (SNRs) at low exposure levels owing to noise sources from the pixel readout circuitry. Current-mediated amorphous silicon pixels are an improvement over conventional pixel amplifiers with an enhanced SNR across the same low-exposure range, but whose output also becomes nonlinear with increasing dosage. A low-noise SNR enhancing readout circuit has been developed that enhances the charge gain of the current-mediated active pixel sensor (C-APS). The solution takes advantage of the current-mediated approach, primarily integrating the signal input at the desired frequency necessary for large-area imaging, while adding minimal noise to the signal readout. Experimental data indicates that the readout circuit can detect pixel outputs over a large bandwidth suitable for real-time digital diagnostic x-ray fluoroscopy. Results from hardware testing indicate that the minimum achievable C-APS output current that can be discerned at the digital fluoroscopic output from the enhanced SNR readout circuit is 0.341 nA. The results serve to highlight the applicability of amorphous silicon current-mediated pixel amplifiers for large-area flat panel x-ray imagers

  7. Principles of fuel ion ratio measurements in fusion plasmas by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Nielsen, Stefan Kragh; Bindslev, Henrik

    2011-01-01

    ratio. Measurements of the fuel ion ratio will be important for plasma control and machine protection in future experiments with burning fusion plasmas. Here we examine the theoretical basis for fuel ion ratio measurements by CTS. We show that the sensitivity to plasma composition is enhanced......For certain scattering geometries collective Thomson scattering (CTS) measurements are sensitive to the composition of magnetically confined fusion plasmas. CTS therefore holds the potential to become a new diagnostic for measurements of the fuel ion ratio—i.e. the tritium to deuterium density...... by the signatures of ion cyclotron motion and ion Bernstein waves which appear for scattering geometries with resolved wave vectors near perpendicular to the magnetic field. We investigate the origin and properties of these features in CTS spectra and give estimates of their relative importance for fuel ion ratio...

  8. The diffuse source at the center of LMC SNR 0509–67.5 is a background galaxy at z = 0.031

    International Nuclear Information System (INIS)

    Pagnotta, Ashley; Walker, Emma S.; Schaefer, Bradley E.

    2014-01-01

    Type Ia supernovae (SNe Ia) are well-known for their use in the measurement of cosmological distances, but our continuing lack of concrete knowledge about their progenitor stars is both a matter of debate and a source of systematic error. In our attempts to answer this question, we presented unambiguous evidence that LMC SNR 0509–67.5, the remnant of an SN Ia that exploded in the Large Magellanic Cloud 400 ± 50 yr ago, did not have any point sources (stars) near the site of the original supernova explosion, from which we concluded that this particular supernova must have had a progenitor system consisting of two white dwarfs. There is, however, evidence of nebulosity near the center of the remnant, which could have been left over detritus from the less massive WD, or could have been a background galaxy unrelated to the supernova explosion. We obtained long-slit spectra of the central nebulous region using GMOS on Gemini South to determine which of these two possibilities is correct. The spectra show Hα emission at a redshift of z = 0.031, which implies that the nebulosity in the center of LMC SNR 0509–67.5 is a background galaxy, unrelated to the supernova.

  9. Differential GPS effectiveness in measuring area and perimeter in forested settings

    International Nuclear Information System (INIS)

    Frank, Jereme; Wing, Michael G

    2013-01-01

    This study quantifies area and perimeter measurement errors, traverse times, recording intervals, and overall time and cost effectiveness for using a mapping-grade differential Global Positioning System (GPS) receiver in forested settings. We compared two configurations including one that maximized data collection productivity (position dilution of precision (PDOP) 20, signal to noise ratio (SNR 33), and minimum elevation mask 5°) and a second that involved traditional receiver settings that was designed to improve accuracies (PDOP 6, SNR 39, and minimum elevation mask 15°). We determined that averaging 30 positions and using the settings that maximized productivity was the most time effective combination of recording interval and settings. This combination of recording interval and settings proved slightly more cost effective than other traditional surveying methods such as a laser with digital compass and string box. Average absolute per cent area errors when averaging 30 positions and using maximum settings were 2.6% and average absolute per cent perimeter errors were 2.0%. These results should help forest resource professionals more effectively evaluate GPS techniques and receiver configurations. (paper)

  10. Post-irradiation creep properties of four plates and two forgings DIN 1.4948 steel from the SNR-300 permanent primary structures

    International Nuclear Information System (INIS)

    Schaaf, B. van der.

    1987-01-01

    The safety authorities, involved in the licensing procedure of the SNR-300, have required the determination of the irradiation effect on the heat-to-heat variation of tensile and creep properties of Werkst. No. DIN 1.4948 austenitic stainless steel. These data are lacking in the present codes and they are necessary for the design and safety considerations of the permanent structures. Results are presented of about 200 tests on irradiated and unirradiated material of 6 heats used in the production of the SNR-300 permanent structures. After irradiation in the HFR-Petten to neutron fluences relevant for the SNR-300 service conditions post-irradiation tensile and creep tests (up to 10,000 hrs rupture time) were performed in the temperature range 723 K to 923 K. All heats are embrittled by irradiation resulting in reduction of rupture times, creep strength and ultimate tensile strength. The considerable reduction is attributed to helium enhanced intergranular creep crack growth, which reduces the ductility and strength, but does not affect the creep rate. The variation of tensile and creep properties is large and independent of irradiation. The minimum derived creep strength in irradiated condition drops below the values expected in the ASME Code and VdTuV Blatt. In design and safety analyses the irradiation effect on creep properties must be accounted for with an appropriate reduction factor. The predictions given, have to be verified with long-term creep tests and parts of the SNR surveillance programme. 172 figs.; 17 refs.; 58 tables

  11. A Method to Optimize Geometric Errors of Machine Tool based on SNR Quality Loss Function and Correlation Analysis

    Directory of Open Access Journals (Sweden)

    Cai Ligang

    2017-01-01

    Full Text Available Instead improving the accuracy of machine tool by increasing the precision of key components level blindly in the production process, the method of combination of SNR quality loss function and machine tool geometric error correlation analysis to optimize five-axis machine tool geometric errors will be adopted. Firstly, the homogeneous transformation matrix method will be used to build five-axis machine tool geometric error modeling. Secondly, the SNR quality loss function will be used for cost modeling. And then, machine tool accuracy optimal objective function will be established based on the correlation analysis. Finally, ISIGHT combined with MATLAB will be applied to optimize each error. The results show that this method is reasonable and appropriate to relax the range of tolerance values, so as to reduce the manufacturing cost of machine tools.

  12. Robust Frame Synchronization for Low Signal-to-Noise Ratio Channels Using Energy-Corrected Differential Correlation

    Directory of Open Access Journals (Sweden)

    Kim Pansoo

    2009-01-01

    Full Text Available Recent standards for wireless transmission require reliable synchronization for channels with low signal-to-noise ratio (SNR as well as with a large amount of frequency offset, which necessitates a robust correlator structure for the initial frame synchronization process. In this paper, a new correlation strategy especially targeted for low SNR regions is proposed and its performance is analyzed. By utilizing a modified energy correction term, the proposed method effectively reduces the variance of the decision variable to enhance the detection performance. Most importantly, the method is demonstrated to outperform all previously reported schemes by a significant margin, for SNRs below 5 dB regardless of the existence of the frequency offsets. A variation of the proposed method is also presented for further enhancement over the channels with small frequency errors. The particular application considered for the performance verification is the second generation digital video broadcasting system for satellites (DVB-S2.

  13. An 8-channel transceiver 7-channel receive RF coil setup for high SNR ultrahigh-field MRI of the shoulder at 7T.

    Science.gov (United States)

    Rietsch, Stefan H G; Pfaffenrot, Viktor; Bitz, Andreas K; Orzada, Stephan; Brunheim, Sascha; Lazik-Palm, Andrea; Theysohn, Jens M; Ladd, Mark E; Quick, Harald H; Kraff, Oliver

    2017-12-01

    In this work, we present an 8-channel transceiver (Tx/Rx) 7-channel receive (Rx) radiofrequency (RF) coil setup for 7 T ultrahigh-field MR imaging of the shoulder. A C-shaped 8-channel Tx/Rx coil was combined with an anatomically close-fitting 7-channel Rx-only coil. The safety and performance parameters of this coil setup were evaluated on the bench and in phantom experiments. The 7 T MR imaging performance of the shoulder RF coil setup was evaluated in in vivo measurements using a 3D DESS, a 2D PD-weighted TSE sequence, and safety supervision based on virtual observation points. Distinct SNR gain and acceleration capabilities provided by the additional 7-channel Rx-only coil were demonstrated in phantom and in vivo measurements. The power efficiency indicated good performance of each channel and a maximum B 1 + of 19 μT if the hardware RF power limits of the MR system were exploited. MR imaging of the shoulder was demonstrated with clinically excellent image quality and submillimeter spatial resolution. The presented 8-channel transceiver 7-channel receive RF coil setup was successfully applied for in vivo 7 T MRI of the shoulder providing a clear SNR gain vs the transceiver array without the additional receive array. Homogeneous images across the shoulder region were obtained using 8-channel subject-specific phase-only RF shimming. © 2017 American Association of Physicists in Medicine.

  14. A CHANDRA OBSERVATION OF SNR 0540 - 697

    International Nuclear Information System (INIS)

    Seward, F. D.; Williams, R. M.; Chu, Y.-H.; Gruendl, R. A.; Dickel, J. R.

    2010-01-01

    This paper describes a Chandra observation of SNR 0540 - 697 within the H II complex N159 in the Large Magellanic Cloud (LMC). Scattering from the nearby bright source LMC X-1, which obscures the western edge of the remnant, has been removed. Larger than previously believed, the 2.'0 x 2.'8 remnant is defined by optical filaments and two lobes of X-ray emission. A band of intervening material absorbs X-rays from the central part of the remnant. The N Lobe of the remnant is relatively bright and well defined, while emission from the S Lobe is much weaker. There is structure within the N Lobe but no clear X-ray emission from an outer shell indicating a shock in the interstellar medium. The X-ray spectrum is thermal with emission lines from Fe, Mg, and Si. The observed temperature and luminosity of the hot gas are 0.6 keV and 6 x 10 35 erg s -1 , respectively. These are consistent with characteristics expected for older remnants. There is also diffuse thermal X-ray emission north of N159 extending into N160, evidence for a larger remnant or bubble.

  15. Tolerance analysis in manufacturing using process capability ratio with measurement uncertainty

    DEFF Research Database (Denmark)

    Mahshid, Rasoul; Mansourvar, Zahra; Hansen, Hans Nørgaard

    2017-01-01

    . In this paper, a new statistical analysis was applied to manufactured products to assess achieved tolerances when the process is known while using capability ratio and expanded uncertainty. The analysis has benefits for process planning, determining actual precision limits, process optimization, troubleshoot......Tolerance analysis provides valuable information regarding performance of manufacturing process. It allows determining the maximum possible variation of a quality feature in production. Previous researches have focused on application of tolerance analysis to the design of mechanical assemblies...... malfunctioning existing part. The capability measure is based on a number of measurements performed on part’s quality variable. Since the ratio relies on measurements, elimination of any possible error has notable negative impact on results. Therefore, measurement uncertainty was used in combination with process...

  16. Measurements of K shell absorption jump factors and jump ratios using EDXRF technique

    Science.gov (United States)

    Kacal, Mustafa Recep; Han, İbrahim; Akman, Ferdi

    2015-04-01

    In the present work, the K-shell absorption jump factors and jump ratios for 30 elements between Ti ( Z = 22) and Er ( Z = 68) were measured by energy dispersive X-ray fluorescence (EDXRF) technique. The jump factors and jump ratios for these elements were determined by measuring the K shell fluorescence parameters such as the Kα X-ray production cross-sections, K shell fluorescence yields, Kβ-to- Kα X-rays intensity ratios, total atomic absorption cross sections and mass attenuation coefficients. The measurements were performed using an Am-241 radioactive point source and a Si (Li) detector in direct excitation and transmission experimental geometry. The results for jump factors and jump ratios were compared with theoretically calculated and the ones available in the literature.

  17. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

    Science.gov (United States)

    van Gastel, Mark; Stuijk, Sander; de Haan, Gerard

    2016-12-07

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO 2 ) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO 2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted by motion-induced variations. We introduce a new principle that allows accurate remote measurements even during significant subject motion. We demonstrate the main advantage of the principle, i.e. that the optimal signature remains the same even when the SNR of the PPG signal drops significantly due to motion or limited measurement area. The evaluation uses recordings with breath-holding events, which induce hypoxemia in healthy moving subjects. The events lead to clinically relevant SpO 2 levels in the range 80-100%. The new principle is shown to greatly outperform current remote ratio-of-ratios based methods. The mean-absolute SpO 2 -error (MAE) is about 2 percentage-points during head movements, where the benchmark method shows a MAE of 24 percentage-points. Consequently, we claim ours to be the first method to reliably measure SpO 2 remotely during significant subject motion.

  18. Discovery of dominant and dormant genes from expression data using a novel generalization of SNR for multi-class problems

    Directory of Open Access Journals (Sweden)

    Chung I-Fang

    2008-10-01

    Full Text Available Abstract Background The Signal-to-Noise-Ratio (SNR is often used for identification of biomarkers for two-class problems and no formal and useful generalization of SNR is available for multiclass problems. We propose innovative generalizations of SNR for multiclass cancer discrimination through introduction of two indices, Gene Dominant Index and Gene Dormant Index (GDIs. These two indices lead to the concepts of dominant and dormant genes with biological significance. We use these indices to develop methodologies for discovery of dominant and dormant biomarkers with interesting biological significance. The dominancy and dormancy of the identified biomarkers and their excellent discriminating power are also demonstrated pictorially using the scatterplot of individual gene and 2-D Sammon's projection of the selected set of genes. Using information from the literature we have shown that the GDI based method can identify dominant and dormant genes that play significant roles in cancer biology. These biomarkers are also used to design diagnostic prediction systems. Results and discussion To evaluate the effectiveness of the GDIs, we have used four multiclass cancer data sets (Small Round Blue Cell Tumors, Leukemia, Central Nervous System Tumors, and Lung Cancer. For each data set we demonstrate that the new indices can find biologically meaningful genes that can act as biomarkers. We then use six machine learning tools, Nearest Neighbor Classifier (NNC, Nearest Mean Classifier (NMC, Support Vector Machine (SVM classifier with linear kernel, and SVM classifier with Gaussian kernel, where both SVMs are used in conjunction with one-vs-all (OVA and one-vs-one (OVO strategies. We found GDIs to be very effective in identifying biomarkers with strong class specific signatures. With all six tools and for all data sets we could achieve better or comparable prediction accuracies usually with fewer marker genes than results reported in the literature using the

  19. Steam generators under construction for the SNR-300 power plant

    Energy Technology Data Exchange (ETDEWEB)

    Essebaggers, J

    1975-07-01

    The prototype straight tube and the helical coil-steam generator has been designed and fabricated of which the straight tube steam generator has been successfully tested for over 3000 hours at prototypical conditions and is presently being dismantled for detailed examination of critical designed features. The prototype helical coil steam generator is presently under testing in the 50 MWt test facility at TNO-Hengelo with approximately 500 hours of operation at full load conditions. In an earlier presentation the design and fabrication of the prototype steam generators have been presented, while for this presentation the production units for SNR-300 will be discussed. Some preliminary information will be presented at this meeting of the dismantling operations of the prototype straight tube steam generator. (author)

  20. Steam generators under construction for the SNR-300 power plant

    International Nuclear Information System (INIS)

    Essebaggers, J.

    1975-01-01

    The prototype straight tube and the helical coil-steam generator has been designed and fabricated of which the straight tube steam generator has been successfully tested for over 3000 hours at prototypical conditions and is presently being dismantled for detailed examination of critical designed features. The prototype helical coil steam generator is presently under testing in the 50 MWt test facility at TNO-Hengelo with approximately 500 hours of operation at full load conditions. In an earlier presentation the design and fabrication of the prototype steam generators have been presented, while for this presentation the production units for SNR-300 will be discussed. Some preliminary information will be presented at this meeting of the dismantling operations of the prototype straight tube steam generator. (author)

  1. Measurement of the initial conversion ratio in AQUILON and EDF 2 reactors

    International Nuclear Information System (INIS)

    Bergeron, J.; Le Baud, P.; Sautiez, B.

    1968-01-01

    In natural uranium fuelled reactors, it is important to know the initial conversion ratio, i.e. the ratio of uranium 238 absorption to uranium 235 destruction. The separation of absorption products from fission products is a difficult feature in the measurement of the conversion ratio. A physical method was chosen, the γγ coincidence technique which uses the properties of the decay scheme of neptunium 239 and allows the neptunium activity to be separated from the fission product activity, with some corrections. Detectors of natural uranium are used. The accuracy obtained in the measurements is of the order of 2%. (authors) [fr

  2. Clear air boundary layer spaced antenna wind measurement with the Multiple Antenna Profiler (MAPR

    Directory of Open Access Journals (Sweden)

    S. A. Cohn

    Full Text Available Spaced antenna (SA wind measurement techniques are applied to Multiple Antenna Profiler (MAPR data to evaluate its performance in clear air conditions. MAPR is a multiple antenna 915 MHz wind profiler developed at the National Center for Atmospheric Research (NCAR and described in Cohn et al. (1997, designed to make high resolution wind measurements. Previous reported measurements with MAPR were restricted to precipitation because of low signal to noise (SNR and signal to ground-clutter (SCR ratios. By using a standard pulse-coding technique and upgrading the profiler control software, increases in average power and SNR were achieved, making routine measurements in clear air possible. Comparison of winds measured by MAPR and by a sonic anemometer on a nearby 300 m tower show correlation coefficients in the range of R2 = 0.75 – 0.80, and an average absolute error of ~ 1.4 m s - 1 . This compares favorably with the agreement typically found in wind profiler comparisons. We also consider the use of the parameter ah , which is related to the value of the cross-correlation function at its zero crossing. This parameter is a data quality indicator and possibly a key component in a ground clutter removal technique.

    Key words. Meteorology and atmospheric dynamics (mesoscale meteorology; instruments and techniques – Radio science (remote sensing

  3. Research on maximum level noise contaminated of remote reference magnetotelluric measurements using synthesized data

    Science.gov (United States)

    Gang, Zhang; Fansong, Meng; Jianzhong, Wang; Mingtao, Ding

    2018-02-01

    Determining magnetotelluric impedance precisely and accurately is fundamental to valid inversion and geological interpretation. This study aims to determine the minimum value of signal-to-noise ratio (SNR) which maintains the effectiveness of remote reference technique. Results of standard time series simulation, addition of different Gaussian noises to obtain the different SNR time series, and analysis of the intermediate data, such as polarization direction, correlation coefficient, and impedance tensor, show that when the SNR value is larger than 23.5743, the polarization direction disorder at morphology and a smooth and accurate sounding carve value can be obtained. At this condition, the correlation coefficient value of nearly complete segments between the base and remote station is larger than 0.9, and impedance tensor Zxy presents only one aggregation, which meet the natural magnetotelluric signal characteristic.

  4. Design, characterization and optimization of various β γ measurement systems

    International Nuclear Information System (INIS)

    Schroettner, T.

    2010-01-01

    This thesis is based on four peer reviewed publications and reflects the scientific work from 2002 to 2009. These four papers correspond to four main chapters of the thesis. The common sense of the work is the focus on physics and electronics of measurement systems for ionizing radiation. The common aim is to increase measurement performance and sensitivity by increasing the signal to noise ratio (SNR). This has been realized by reduction of the terrestrial and cosmic radiation background and by minimizing of electromagnetic interference (EMI) and noise pick up by electronic measures. Another method, applied to increase the SNR, utilized adaptive integration time to optimize the ratio of recorded signal and background counts. For spectroscopic systems, also the stability of the energy calibration plays a key role for high SNR, as the detection limit depends on the energy resolution and stability of energy calibration. The first paper 'Optimization of an active anti cosmic veto shielding' (Schroettner at al., 2004) deals with optimization of a low level gamma spectroscopy system. Time spectroscopy of the cosmic muons passing the guard detector and the related background signals in the high purity germanium (HPGe) detector has been applied to optimize the veto time window. The fluctuation of the muon flux has been investigated and the possible induced drop and variation of measurement efficiency have been calculated and minimized. To extend the operation of the active veto towards lower γ-energies, the electronic noise and interference has been reduced by systematic location and elimination of the sources. A totally isolated power net employs filtering and regeneration of the power line for the laboratory. The second paper 'Enhancing sensitivity of portal monitoring at varying transit speed' (Schroettner at al., 2009) contains a characterization of a plastic scintillation based portal monitoring system and presents a method to increase the sensitivity of the system

  5. Comparison of the performance of different radar pulse compression techniques in an incoherent scatter radar measurement

    Directory of Open Access Journals (Sweden)

    B. Damtie

    2009-02-01

    Full Text Available Improving an estimate of an incoherent scatter radar signal is vital to provide reliable and unbiased information about the Earth's ionosphere. Thus optimizing the measurement spatial and temporal resolutions has attracted considerable attention. The optimization usually relies on employing different kinds of pulse compression filters in the analysis and a matched filter is perhaps the most widely used one. A mismatched filter has also been used in order to suppress the undesirable sidelobes that appear in the case of matched filtering. Moreover, recently an adaptive pulse compression method, which can be derived based on the minimum mean-square error estimate, has been proposed. In this paper we have investigated the performance of matched, mismatched and adaptive pulse compression methods in terms of the output signal-to-noise ratio (SNR and the variance and bias of the estimator. This is done by using different types of optimal radar waveforms. It is shown that for the case of low SNR the signal degradation associated to an adaptive filtering is less than that of the mismatched filtering. The SNR loss of both matched and adaptive pulse compression techniques was found to be nearly the same for most of the investigated codes for the case of high SNR. We have shown that the adaptive filtering technique is a compromise between matched and mismatched filtering method when one evaluates its performance in terms of the variance and the bias of the estimator. All the three analysis methods were found to have the same performance when a sidelobe-free matched filter code is employed.

  6. Comparison of the performance of different radar pulse compression techniques in an incoherent scatter radar measurement

    Directory of Open Access Journals (Sweden)

    B. Damtie

    2009-02-01

    Full Text Available Improving an estimate of an incoherent scatter radar signal is vital to provide reliable and unbiased information about the Earth's ionosphere. Thus optimizing the measurement spatial and temporal resolutions has attracted considerable attention. The optimization usually relies on employing different kinds of pulse compression filters in the analysis and a matched filter is perhaps the most widely used one. A mismatched filter has also been used in order to suppress the undesirable sidelobes that appear in the case of matched filtering. Moreover, recently an adaptive pulse compression method, which can be derived based on the minimum mean-square error estimate, has been proposed. In this paper we have investigated the performance of matched, mismatched and adaptive pulse compression methods in terms of the output signal-to-noise ratio (SNR and the variance and bias of the estimator. This is done by using different types of optimal radar waveforms. It is shown that for the case of low SNR the signal degradation associated to an adaptive filtering is less than that of the mismatched filtering. The SNR loss of both matched and adaptive pulse compression techniques was found to be nearly the same for most of the investigated codes for the case of high SNR. We have shown that the adaptive filtering technique is a compromise between matched and mismatched filtering method when one evaluates its performance in terms of the variance and the bias of the estimator. All the three analysis methods were found to have the same performance when a sidelobe-free matched filter code is employed.

  7. Influence of skew rays on the sensitivity and signal-to-noise ratio of a fiber-optic surface-plasmon-resonance sensor: a theoretical study

    International Nuclear Information System (INIS)

    Dwivedi, Yogendra S.; Sharma, Anuj K.; Gupta, Banshi D.

    2007-01-01

    We have theoretically analyzed the influence of skew rays on the performance of a fiber-optic sensor based on surface plasmon resonance. The performance of the sensor has been evaluated in terms of its sensitivity and signal-to-noise ratio (SNR). The theoretical model for skewness dependence includes the material dispersion in fiber cores and metal layers, simultaneous excitation of skew rays, and meridional rays in the fiber core along with all guided rays launching from a collimated light source. The effect of skew rays on the SNR and the sensitivity of the sensor with two different metals has been compared. The same comparison is carried out for the different values of design parameters such as numerical aperture, fiber core diameter, and the length of the surface-plasmon-resonance (SPR)active sensing region. This detailed analysis for the effect of skewness on the SNR and the sensitivity of the sensor leads us to achieve the best possible performance from a fiber-optic SPR sensor against the skewness in the optical fiber

  8. Image fusion in dual energy computed tomography for detection of various anatomic structures - Effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jijo, E-mail: jijopaul1980@gmail.com [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Department of Biophysics, Goethe University, Max von Laue-Str.1, 60438 Frankfurt am Main (Germany); Bauer, Ralf W. [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Maentele, Werner [Department of Biophysics, Goethe University, Max von Laue-Str.1, 60438 Frankfurt am Main (Germany); Vogl, Thomas J. [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2011-11-15

    Objective: The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Material and methods: Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mA s; collimation-2 x 32 x 0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test. Results: Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P {<=} 0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2 {+-} 12.8 Hounsfield Units (HU), 204.8 {+-} 14.4 HU, 267.5 {+-} 18.6 HU, 311.9 {+-} 22.3 HU, 347.3 {+-} 24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P = 0.012 and P = 0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the

  9. Image fusion in dual energy computed tomography for detection of various anatomic structures - Effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality

    International Nuclear Information System (INIS)

    Paul, Jijo; Bauer, Ralf W.; Maentele, Werner; Vogl, Thomas J.

    2011-01-01

    Objective: The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Material and methods: Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mA s; collimation-2 x 32 x 0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test. Results: Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P ≤ 0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2 ± 12.8 Hounsfield Units (HU), 204.8 ± 14.4 HU, 267.5 ± 18.6 HU, 311.9 ± 22.3 HU, 347.3 ± 24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P = 0.012 and P = 0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the weighting factor 0

  10. Submillimeter/millimeter observations of the molecular clouds associated with Tycho's supernova remnant

    International Nuclear Information System (INIS)

    Xu Jinlong; Wang Junjie; Miller, Martin

    2011-01-01

    We have carried out CO J = 2 - 1 and CO J = 3 - 2 observations toward Tycho's supernova remnant (SNR) using the KOSMA 3m-telescope. From these observations, we identified three molecular clouds (MCs) around the SNR. The small cloud in the southwest was discovered for the first time. In the north and east, two MCs (Cloud A and Cloud B) adjacent in space display a bow-shaped morphology, and have broad emission lines, which provide some direct evidences of the SNR-MCs interaction. The MCs are revealed at -69∼ -59 km s -1 , coincident with Tycho's SNR. The MCs associated with Tycho's SNR have a mass of ∼ 2.13 x 10 3 M circleddot . Position-velocity diagrams show the two clouds to be adjacent in velocity, which means cloud-cloud collision could occur in this region. The maximum value (0.66 ± 0.10) of the integrated CO line intensity ratio (I COJ=3-2 /I COJ=2-1 ) for the three MCs agrees well with the previous measurement of individual Galactic MCs, implying that the SNR shock drove into the MCs. The two MCs have a line intensity ratio gradient. The distribution of the ratio appears to indicate that the shock propagates from the southwest to the northeast.

  11. New Measurement of the π → eν branching ratio

    International Nuclear Information System (INIS)

    Dixit, M.S.; Bryman, D.A.; Dubois, R.; Numao, T.; Olaniyi, B.; Olin, A.; Berghofer, D.; Poutissou, J.-M.; Macdonald, J.A.

    1982-11-01

    A new measurement of the π → eν branching ratio yields GAMMA(π→eν + π→eνγ) / GAMMA(π→μν + π→γνμ) = (1.218 +- 0.014) x 10 -4 . The measured value is in good agreement with the standard model prediction incorporating electron-muon universality

  12. SNR in ultrasonic pluse compression using Golay codes

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Kim, Young Gil; Jeong, Peter

    1994-01-01

    The conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer, however, these systems are limited in average transmit power. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse cuases decrease of the resolution. Using the pulse compression, a long pulse of psudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was utilized to the ultrasonic system. Golay code was used as a psudorandom signal in this system, since pair sum of auto-correlations has not sidelobe. The equivalent input pulse of the Golay code was proposed to analyze the pulse compression system. In experiment, the material type, material thickness and code length were considered. As results, pulse compression system considerably reduced system's white noise, and approximately 30 dB improvement in SNR was obtained over the conventional ultrasonic system. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  13. Study of the containment system of the planned SNR-2 Fast Breeder Reactor

    International Nuclear Information System (INIS)

    Bunz, H.; Scholle, U.

    1979-01-01

    Research is presented concerning the behaviour of four possible containment concepts for the planned Fast Breeder Reactor SNR-2 under the conditions of a HCDA. Detailed descriptions and calculations are given dealing with the acceptable leakages and the filter loads reached. The transport of the aerosol-type as well as the gaseous activity through the different compartments into the environment is calculated and from this the resulting accident doses. To cover the uncertainties of the accident course a wide range of accident parameters is examined

  14. The value of pulmonary vessel CT measuring and calculating of relative ratio

    International Nuclear Information System (INIS)

    Ji Jiansong; Xu Xiaoxiong; Lv Suzhen; Zhao Zhongwei; Wang Zufei; Xu Min; Gong Jianping

    2004-01-01

    Objective: To evaluate value of CT measurement and calculation of vessels of isolate pig lung, by compare with measurement and calculation of resin cast of them. Methods: CT scanned and measured the four isolated pig lung which vessels were full with ABS liquid or self-solidification resin liquid, and calculate the relative ratio of superior/inferior order and vein/artery of same order. After resin cast were made, measure and calculate the same as CT did. Results: Second order of calculation of vein/artery of same order by the two method had statistic difference (P 0.05). Conclusion: CT has high value in calculation of the relative ratio of superior/inferior order

  15. SNR and BER Models and the Simulation for BER Performance of Selected Spectral Amplitude Codes for OCDMA

    Directory of Open Access Journals (Sweden)

    Abdul Latif Memon

    2014-01-01

    Full Text Available Many encoding schemes are used in OCDMA (Optical Code Division Multiple Access Network but SAC (Spectral Amplitude Codes is widely used. It is considered an effective arrangement to eliminate dominant noise called MAI (Multi Access Interference. Various codes are studied for evaluation with respect to their performance against three noises namely shot noise, thermal noise and PIIN (Phase Induced Intensity Noise. Various Mathematical models for SNR (Signal to Noise Ratios and BER (Bit Error Rates are discussed where the SNRs are calculated and BERs are computed using Gaussian distribution assumption. After analyzing the results mathematically, it is concluded that ZCC (Zero Cross Correlation Code performs better than the other selected SAC codes and can serve larger number of active users than the other codes do. At various receiver power levels, analysis points out that RDC (Random Diagonal Code also performs better than the other codes. For the power interval between -10 and -20 dBm performance of RDC is better ZCC. Their lowest BER values suggest that these codes should be part of an efficient and cost effective OCDM access network in the future.

  16. Magnetic Resonance Signal Intensity Ratio Measurement Before Uterine Artery Embolization

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Ravn, Pernille; Green, Anders

    2017-01-01

    , 52 patients were included in this prospective study. The SI ratio before UFE was calculated using circular region of interests placed on the dominant fibroid and the iliac muscle. The SI fibroid-to-iliac muscle ratio was calculated as SI of the dominant fibroid/SI of the iliac muscle on T1-, T2......-, and T1 post-contrast-weighted sequences. The dominant fibroid volume was measured and analyzed before and after UFE. RESULTS: In all, 46 patients who completed the three-month follow-up MRI were available for analysis. The correlation between SI fibroid-to-muscle ratio at the T2-weighted sequence...... positive correlation (r = 0.439, p T2-weighted sequence. The area under curve (AUC) for SI fibroid-to-muscle ratio on T2-weighted sequence was 0.776. For the other parameters, the AUC values were 0.512, 0.671, and 0.578, respectively. CONCLUSION: SI...

  17. Measurement of the atmospheric muon charge ratio with the OPERA detector

    International Nuclear Information System (INIS)

    Agafonova, N.; Boyarkin, V.; Enikeev, R.; Malgin, A.; Matveev, V.; Ryasny, V.; Ryazhskaya, O.; Yakushev, V.; Anokhina, A.; Galkin, V.I.; Nikitina, V.; Osedlo, V.; Publichenko, P.; Roganova, T.; Aoki, S.; Hara, T.; Rokujo, H.; Ariga, A.; Ariga, T.; Ereditato, A.; Juget, F.; Knuesel, J.; Kreslo, I.; Lutter, G.; Meisel, F.; Moser, U.; Pistillo, C.; Pretzl, K.; Vuilleumier, J.L.; Autiero, D.; Brugiere, T.; Cazes, A.; Chaussard, L.; Declais, Y.; Marteau, J.; Pennacchio, E.; Tran, T.; Badertscher, A.; Lazzaro, C.; Rubbia, A.; Strauss, T.; Bagulya, A.; Chernyavsky, M.; Goncharova, L.; Orlova, G.; Polukhina, N.; Starkov, N.; Vladimirov, M.; Bertolin, A.; Dal Corso, F.; Dusini, S.; Besnier, M.; Duchesneau, D.; Favier, J.; Pessard, H.; Zghiche, A.; Bick, D.; Ebert, J.; Ferber, T.; Goellnitz, C.; Hagner, C.; Lenkeit, J.; Oldorf, C.; Schmidt Parzefall, W.; Wonsak, B.; Zimmermann, R.; Bozza, C.; D'Amato, G.; Grella, G.; Policastro, G.; Rescigno, R.; Romano, G.; Sirignano, C.; Brugnera, R.; Garfagnini, A.; Kose, U.; Brunetti, G.; Giacomelli, G.; Giorgini, M.; Mauri, N.; Pozzato, M.; Sioli, M.; Tenti, M.; Buontempo, S.; Chukanov, A.; Di Capua, F.; Marotta, A.; Migliozzi, P.; Scotto Lavina, L.; Tioukov, V.; Chiarella, V.; Felici, G.; Grianti, F.; Paniccia, M.; Paoloni, A.; Spinetti, M.; Terranova, F.; Votano, L.; Chon-Sen, N.; Dracos, M.; Jollet, C.; Meregaglia, A.; Cozzi, M.; D'Ambrosio, N.; Di Giovanni, A.; Esposito, L.S.; Gustavino, C.; De Lellis, G.; Russo, A.; Strolin, P.; De Serio, M.; Fini, R.; Ieva, M.; Di Ferdinando, D.; Mandrioli, G.; Medinaceli, E.; Patrizii, L.; Sirri, G.; Di Marco, N.; Monacelli, P.; Park, B.D.; Park, I.G.; Pupilli, F.; Dmitrievski, S.; Gornushkin, Y.; Naumov, D.; Olchevski, A.; Sheshukov, A.; Zemskova, S.; Egorov, O.; Golubkov, D.; Rostovtseva, I.; Zaitsev, Y.; Frekers, D.; Pilipenko, V.; Fukuda, T.; Hamada, K.; Hoshino, K.; Kazuyama, M.; Komatsu, M.; Kubota, H.; Miyamoto, S.; Morishima, K.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Niwa, K.; Nonoyama, Y.; Sato, O.; Takahashi, S.; Yoshioka, T.; Yoshida, J.; Fukushima, C.; Kimura, M.; Matsuo, T.; Mikado, S.; Ogawa, S.; Shibuya, H.; Goldberg, J.; Guler, M.; Tolun, P.; Tufanli, S.; Hierholzer, M.; Jakovcic, K.; Klicek, B.; Ljubicic, A.; Stipcevic, M.; Kim, S.H.; Song, J.S.; Yoon, C.S.; Kodama, K.; Longhin, A.; Stanco, L.; Muciaccia, M.T.; Pastore, A.; Simone, S.; Rosa, G.; Schembri, A.; Sato, Y.; Tezuka, I.; Schroeder, H.; Vilain, P.; Wilquet, G.

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio R μ =N μ + /N μ - in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of lifetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the R μ dependence on the primary composition. The measured R μ values were corrected taking into account the charge-misidentification errors. Data have also been grouped in five bins of the ''vertical surface energy'' E μ cos θ. A fit to a simplified model of muon production in the atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum. (orig.)

  18. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  19. The Fast Breeder SNR 300 in the ups and downs of its history

    International Nuclear Information System (INIS)

    Marth, W.

    1992-03-01

    The Fast Breeder Project was founded in 1960 at Karlsruhe. After an initial period of basic research, the industry took over the design of SRN 300. Affected by various political influences, the construction of the nuclear power plant Kalkar was disturbed and delayed, but was finally completed in 1985. However, since the governing party of Nordrhein-Westfalen decided to drop out of nuclear energy, the authorisation for starting up the SNR 300 could not be obtained. Therefore, the Kalkar project was cancelled for political reasons in March 1991. (orig.) [de

  20. The ultimate intrinsic signal-to-noise ratio of loop- and dipole-like current patterns in a realistic human head model.

    Science.gov (United States)

    Pfrommer, Andreas; Henning, Anke

    2018-03-13

    The ultimate intrinsic signal-to-noise ratio (UISNR) represents an upper bound for the achievable SNR of any receive coil. To reach this threshold a complete basis set of equivalent surface currents is required. This study systematically investigated to what extent either loop- or dipole-like current patterns are able to reach the UISNR threshold in a realistic human head model between 1.5 T and 11.7 T. Based on this analysis, we derived guidelines for coil designers to choose the best array element at a given field strength. Moreover, we present ideal current patterns yielding the UISNR in a realistic body model. We distributed generic current patterns on a cylindrical and helmet-shaped surface around a realistic human head model. We excited electromagnetic fields in the human head by using eigenfunctions of the spherical and cylindrical Helmholtz operator. The electromagnetic field problem was solved by a fast volume integral equation solver. At 7 T and above, adding curl-free current patterns to divergence-free current patterns substantially increased the SNR in the human head (locally >20%). This was true for the helmet-shaped and the cylindrical surface. On the cylindrical surface, dipole-like current patterns had high SNR performance in central regions at ultra-high field strength. The UISNR increased superlinearly with B0 in most parts of the cerebrum but only sublinearly in the periphery of the human head. The combination of loop and dipole elements could enhance the SNR performance in the human head at ultra-high field strength. © 2018 International Society for Magnetic Resonance in Medicine.

  1. High-precision branching-ratio measurement for the superallowed β+ emitter 74Rb

    Science.gov (United States)

    Dunlop, R.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Andreoiu, C.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Glister, J.; Hackman, G.; Hadinia, B.; Leach, K. G.; Rand, E. T.; Starosta, K.; Tardiff, E. R.; Triambak, S.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2013-10-01

    A high-precision branching-ratio measurement for the superallowed β+ decay of 74Rb was performed at the TRIUMF Isotope Separator and Accelerator (ISAC) radioactive ion-beam facility. The scintillating electron-positron tagging array (SCEPTAR), composed of 10 thin plastic scintillators, was used to detect the emitted β particles; the 8π spectrometer, an array of 20 Compton-suppressed HPGe detectors, was used for detecting γ rays that were emitted following Gamow-Teller and nonanalog Fermi β+ decays of 74Rb; and the Pentagonal Array of Conversion Electron Spectrometers (PACES), an array of 5 Si(Li) detectors, was employed for measuring β-delayed conversion electrons. Twenty-three excited states were identified in 74Kr following 8.241(4)×108 detected 74Rb β decays. A total of 58 γ-ray and electron transitions were placed in the decay scheme, allowing the superallowed branching ratio to be determined as B0=99.545(31)%. Combined with previous half-life and Q-value measurements, the superallowed branching ratio measured in this work leads to a superallowed ft value of 3082.8(65) s. Comparisons between this superallowed ft value and the world-average-corrected Ft¯ value, as well as the nonanalog Fermi branching ratios determined in this work, provide guidance for theoretical models of the isospin-symmetry-breaking corrections in this mass region.

  2. Deep convective cloud characterizations from both broadband imager and hyperspectral infrared sounder measurements

    Science.gov (United States)

    Ai, Yufei; Li, Jun; Shi, Wenjing; Schmit, Timothy J.; Cao, Changyong; Li, Wanbiao

    2017-02-01

    Deep convective storms have contributed to airplane accidents, making them a threat to aviation safety. The most common method to identify deep convective clouds (DCCs) is using the brightness temperature difference (BTD) between the atmospheric infrared (IR) window band and the water vapor (WV) absorption band. The effectiveness of the BTD method for DCC detection is highly related to the spectral resolution and signal-to-noise ratio (SNR) of the WV band. In order to understand the sensitivity of BTD to spectral resolution and SNR for DCC detection, a BTD to noise ratio method using the difference between the WV and IR window radiances is developed to assess the uncertainty of DCC identification for different instruments. We examined the case of AirAsia Flight QZ8501. The brightness temperatures (Tbs) over DCCs from this case are simulated for BTD sensitivity studies by a fast forward radiative transfer model with an opaque cloud assumption for both broadband imager (e.g., Multifunction Transport Satellite imager, MTSAT-2 imager) and hyperspectral IR sounder (e.g., Atmospheric Infrared Sounder) instruments; we also examined the relationship between the simulated Tb and the cloud top height. Results show that despite the coarser spatial resolution, BTDs measured by a hyperspectral IR sounder are much more sensitive to high cloud tops than broadband BTDs. As demonstrated in this study, a hyperspectral IR sounder can identify DCCs with better accuracy.

  3. Noninvasive measurement of physiological signals on a modified home bathroom scale.

    Science.gov (United States)

    Inan, O T; Dookun Park; Giovangrandi, L; Kovacs, G T A

    2012-08-01

    A commercial bathroom scale with both handlebar and footpad electrodes was modified to enable measurement of four physiological signals: the ballistocardiogram (BCG), electrocardiogram (ECG), lower body impedance plethysmogram (IPG), and lower body electromyogram (EMG). The BCG, which describes the reaction of the body to cardiac ejection of blood, was measured using the strain gauges in the scale. The ECG was detected using handlebar electrodes with a two-electrode amplifier. For the lower body IPG, the two electrodes under the subject's toes were driven with an ac current stimulus, and the resulting differential voltage across the heels was measured and demodulated synchronously with the source. The voltage signal from the same two footpad electrodes under the heels was passed through a passive low-pass filter network into another amplifier, and the output was the lower body EMG signal. The signals were measured from nine healthy subjects, and the average signal-to-noise ratio (SNR) while the subjects were standing still was estimated for the four signals as follows: BCG, 7.6 dB; ECG, 15.8 dB; IPG, 10.7 dB. During periods of motion, the decrease in SNR for the BCG signal was found to be correlated to the increase in rms power for the lower body EMG (r = 0.89, p <; 0.01). The EMG could, thus, be used to flag noise-corrupted segments of the BCG, increasing the measurement robustness. This setup could be used for monitoring the cardiovascular health of patients at home.

  4. Long distance elementary measurement of the radiation dose ratio produced by neutron activation

    International Nuclear Information System (INIS)

    Zhou Changgeng; Lou Benchao; Wu Chunlei; Hu Yonghong; Li Yan

    2009-04-01

    The working principle and the structure and performances of a long distance controllable individual radiation dose ratio instrument are described. The radiation dose ratio produced by neutron activation is elementarily measured by using this instrument in the neutron generator hall with high neutron yield. When neutron yield arrives to 2 x 10 11 s -1 , the radiation dose ratio produced by neutron activation is 99.9 μSv/h in 1 h after the generator being stopped. The radiation dose ratio is reduced to 24.4 μSv/h in 39 h after the generator being stopped. When neutron yield is 3.2 x 10 10 s -1 , the radiation dose ratio produced by neutron activation is 21.9 μSv/h in 36 min, after the generator being stopped. The measurement results may provide reference for physical experimenters and neutron generator operators. (authors)

  5. Differential Drell-Yan measurements and Z/top-pair cross section ratios

    CERN Document Server

    Zinser, Markus; The ATLAS collaboration

    2017-01-01

    Precision measurements of the Drell-Yan production of W and Z bosons at the LHC provide a benchmark of our understanding of perturbative QCD and electroweak processes and probe the proton structure in a unique way. The ATLAS collaboration performed a precision Z/gamma* measurement at a center of mass energy of 8 TeV in the di-lepton mass range up to the TeV scale. These are performed double-differentially in dilepton mass and rapidity or dilepton mass and rapidity separation. The measurements are compared to state-of-the-art theory calculations and are found to bring strong constraints on the high x partons and the poorly constrained photon content of the proton. Z cross sections are also measured at a center-of-mass energies of 8TeV and 13TeV, and cross-section ratios to the top-quark pair production have been derived. This ratio measurement leads to a cancellation of several systematic effects and allows therefore for a high precision comparison to the theory predictions.

  6. Temperature Measurements in the Solar Transition Region Using N III Line Intensity Ratios

    Science.gov (United States)

    Doron, R.; Doschek, G. A.; Laming, J. M.; Feldman, U.; Bhatia, A. K.

    2003-01-01

    UV emission from B-like N and O ions a rather rare opportunity for recording spectral lines in a narrow wavelength range that can potentially be used to derive temperatures relevant to the solar transition region. In these ions, the line intensity ratios of the type (2s2p(sup 2) - 2p(sup 3)) / (2s(sup 2)2p - 2s2p(sup 2)) are very sensitive to the electron temperature. Additionally, the lines involving the ratios fall within a range of only - 12 A; in N III the lines fall in the 980 - 992 A range and in O IV in the 780 - 791 A range. In this work, we explore the use of these atomic systems, primarily in N III, for temperature diagnostics of the transition region by analyzing UV spectra obtained by the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) spectrometer flown on the Solar and Heliospheric Observatory (SOHO). The N III temperature-sensitive line ratios are measured in more than 60 observations. Most of the measured ratios correspond to temperatures in the range 5.7x10(exp 4) - 6.7x10(exp 4) K. This range is considerably lower than the calculated temperature of maximum abundance of N III, which is approx. 7.6x10(exp 4) K. Detailed analysis of the spectra further indicates that the measured ratios are probably somewhat overestimated due to resonant scattering effects in the 2s(sup 2)2p - 2s2p(sup 2) lines and small blends in the 2s2p(sup 2) - 2p3 lines. Actual lower ratios would only increase the disagreement between the ionization balance calculations and present temperature measurements based on a collisional excitation model. In the case of the O IV spectra, we determined that due to the close proximity in wavelength of the weak line (2s2p(sup 2)-2p3 transitions) to a strong Ne VIII line, sufficiently accurate ratio measurements cannot be obtained. Subject headings: atomic data --- atomic processes --- Sun: transition region --- Sun: U V radiation --- techniques: spectroscopic

  7. Activities with regard to research and development of technics for SNR 300 reactor vessel in-service inspection procedures

    International Nuclear Information System (INIS)

    Hoeller, K.; Kirchner, G.; Menck, J.

    1980-01-01

    During the development of SNR 300 in-service inspection equipment, several branches were tested by experiment. In this report special steps for testing of manipulation systems and additional engineering equipment for control systems, such as coupling fluid circuit or camera cooling system are considered more in detail

  8. FERMI LARGE AREA TELESCOPE DISCOVERY OF GeV GAMMA-RAY EMISSION FROM THE VICINITY OF SNR W44

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Yasunobu; Funk, Stefan; Katsuta, Junichiro [SLAC National Accelerator Laboratory, 2575 Sand Hill Road M/S 29, Menlo Park, CA 94025 (United States); Katagiri, Hideaki [College of Science, Ibaraki University, 2-1-1, Bunkyo, Mito 310-8512 (Japan); Lemoine-Goumard, Marianne [Centre d' Etudes Nucleaires de Bordeaux Gradignan, Universite Bordeaux 1, CNRS/IN2p3, 33175 Gradignan (France); Tajima, Hiroyasu; Tanaka, Takaaki [Kavli Institute for Particle Astrophysics and Cosmology, Stanford University, Stanford, CA 94305 (United States); Torres, Diego F., E-mail: uchiyama@slac.stanford.edu [Institut de Ciencies de l' Espai (IEEE-CSIC), Campus UAB, 08193 Barcelona (Spain)

    2012-04-20

    We report the detection of GeV {gamma}-ray emission from the molecular cloud complex that surrounds the supernova remnant (SNR) W44 using the Large Area Telescope on board Fermi. While the previously reported {gamma}-ray emission from SNR W44 is likely to arise from the dense radio-emitting filaments within the remnant, the {gamma}-ray emission that appears to come from the surrounding molecular cloud complex can be ascribed to the cosmic rays (CRs) that have escaped from W44. The non-detection of synchrotron radio emission associated with the molecular cloud complex suggests the decay of {pi}{sup 0} mesons produced in hadronic collisions as the {gamma}-ray emission mechanism. The total kinetic energy channeled into the escaping CRs is estimated to be W{sub esc} {approx} (0.3-3) Multiplication-Sign 10{sup 50} erg, in broad agreement with the conjecture that SNRs are the main sources of Galactic CRs.

  9. Combination of highly nonlinear fiber, an optical bandpass filter, and a Fabry-Perot filter to improve the signal-to-noise ratio of a supercontinuum continuous-wave optical source.

    Science.gov (United States)

    Nan, Yinbo; Huo, Li; Lou, Caiyun

    2005-05-20

    We present a theoretical study of a supercontinuum (SC) continuous-wave (cw) optical source generation in highly nonlinear fiber and its noise properties through numerical simulations based on the nonlinear Schrödinger equation. Fluctuations of pump pulses generate substructures between the longitudinal modes that result in the generation of white noise and then in degradation of coherence and in a decrease of the modulation depths and the signal-to-noise ratio (SNR). A scheme for improvement of the SNR of a multiwavelength cw optical source based on a SC by use of the combination of a highly nonlinear fiber (HNLF), an optical bandpass filter, and a Fabry-Perot (FP) filter is presented. Numerical simulations show that the improvement in modulation depth is relative to the HNLF's length, the 3-dB bandwidth of the optical bandpass filter, and the reflection ratio of the FP filter and that the average improvement in modulation depth is 13.7 dB under specified conditions.

  10. The Measurement of Fuel-Air Ratio by Analysis for the Oxidized Exhaust Gas

    Science.gov (United States)

    Gerrish, Harold C.; Meem, J. Lawrence, Jr.

    1943-01-01

    An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy fuel Specification No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs for the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124.

  11. The Measurement of Fuel-air Ratio by Analysis of the Oxidized Exhaust Gas

    Science.gov (United States)

    Memm, J. Lawrence, Jr.

    1943-01-01

    An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy Fuel Specification, No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs or the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124

  12. Measurement of shoulder motion fraction and motion ratio

    International Nuclear Information System (INIS)

    Kang, Yeong Han

    2006-01-01

    This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR (computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was 15 .deg., 19 .deg., 22 .deg. to the cephald for the parallel scapular spine, and the tilting of torso was external oblique 40 .deg., 36 .deg., 22 .deg. for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age (20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, 90 .deg. and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. While the arm elevation was 90 .deg., the shoulder motion fraction was 1.22 (M), 1.70 (W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84 and left was 1.57, 1.32. In right dominant arm (78%), 90 .deg. and Full motion fraction was 1.58, 1.43, in left (22%) 1.82, 1.94. In generation 20, 90 .deg. and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28,60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. The criteria of motion fraction was useful reference for clinical diagnosis the shoulder instability

  13. DISCOVERY OF TeV GAMMA-RAY EMISSION TOWARD SUPERNOVA REMNANT SNR G78.2+2.1

    Energy Technology Data Exchange (ETDEWEB)

    Aliu, E. [Department of Physics and Astronomy, Barnard College, Columbia University, NY 10027 (United States); Archambault, S. [Physics Department, McGill University, Montreal, QC H3A 2T8 (Canada); Arlen, T.; Aune, T. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Beilicke, M.; Buckley, J. H.; Bugaev, V.; Dickherber, R. [Department of Physics, Washington University, St. Louis, MO 63130 (United States); Benbow, W. [Fred Lawrence Whipple Observatory, Harvard-Smithsonian Center for Astrophysics, Amado, AZ 85645 (United States); Bird, R.; Cannon, A.; Collins-Hughes, E. [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland); Bouvier, A. [Santa Cruz Institute for Particle Physics and Department of Physics, University of California, Santa Cruz, CA 95064 (United States); Bradbury, S. M. [School of Physics and Astronomy, University of Leeds, Leeds, LS2 9JT (United Kingdom); Byrum, K. [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Cesarini, A.; Connolly, M. P. [School of Physics, National University of Ireland Galway, University Road, Galway (Ireland); Ciupik, L. [Astronomy Department, Adler Planetarium and Astronomy Museum, Chicago, IL 60605 (United States); Cui, W. [Department of Physics, Purdue University, West Lafayette, IN 47907 (United States); Duke, C., E-mail: amandajw@iastate.edu [Department of Physics, Grinnell College, Grinnell, IA 50112-1690 (United States); and others

    2013-06-20

    We report the discovery of an unidentified, extended source of very-high-energy gamma-ray emission, VER J2019+407, within the radio shell of the supernova remnant SNR G78.2+2.1, using 21.4 hr of data taken by the VERITAS gamma-ray observatory in 2009. These data confirm the preliminary indications of gamma-ray emission previously seen in a two-year (2007-2009) blind survey of the Cygnus region by VERITAS. VER J2019+407, which is detected at a post-trials significance of 7.5 standard deviations in the 2009 data, is localized to the northwestern rim of the remnant in a region of enhanced radio and X-ray emission. It has an intrinsic extent of 0.23 Degree-Sign .23 {+-} 0. Degree-Sign 03{sub stat-0 Degree-Sign .02sys}{sup +0 Degree-Sign .04} and its spectrum is well-characterized by a differential power law (dN/dE = N{sub 0} Multiplication-Sign (E/TeV){sup -{Gamma}}) with a photon index of {Gamma} = 2.37 {+-} 0.14{sub stat} {+-} 0.20{sub sys} and a flux normalization of N{sub 0} = 1.5 {+-} 0.2{sub stat} {+-} 0.4{sub sys} Multiplication-Sign 10{sup -12} photon TeV{sup -1} cm{sup -2} s{sup -1}. This yields an integral flux of 5.2 {+-} 0.8{sub stat} {+-} 1.4{sub sys} Multiplication-Sign 10{sup -12} photon cm{sup -2} s{sup -1} above 320 GeV, corresponding to 3.7% of the Crab Nebula flux. We consider the relationship of the TeV gamma-ray emission with the GeV gamma-ray emission seen from SNR G78.2+2.1 as well as that seen from a nearby cocoon of freshly accelerated cosmic rays. Multiple scenarios are considered as possible origins for the TeV gamma-ray emission, including hadronic particle acceleration at the SNR shock.

  14. Measurement of lime/silica ratio in concrete using PGNAA technique

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-12-01

    Prompt gamma neutron activation analysis (PGNAA) technique has been used to determine lime/silica ratio in concrete samples using an accelerator-based PGNAA facility. The ratio was determined from the measured yield of 6.42 MeV prompt {gamma}-rays of calcium and 4.93 MeV {gamma}-rays of silicon from the six concrete samples. The experimental results were compared with the results of the Monte Carlo simulations. An excellent agreement has been achieved between the two. The study has demonstrated successful use of the accelerator-based PGNAA setup in non-destructive analysis of the concrete samples.

  15. Comparison of ANL containment codes with SNR-300 simulation experiments

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Wang, C.Y.; Fistedis, S.H.

    1976-01-01

    A comparison of REXCO and ICECO code predictions is made with data obtained from experiments of LMFBR excursion models. The comparisons are based on published results of tests conducted for the safety analysis of the SNR-300 fast breeder. The test configurations consist of a centrally located spherical source immersed in a pool of water which is encased in a cylindrical container. The cylinical walls of the container are prestressed by holddown bolts which span the two rigid ends. The space above the surface of the water within the container is occupied by air. Although certain aspects of the tests could not be simulated by the analytical models exactly, the comparison of results shows quite close agreement. The fact that the REXCO and ICECO codes involve different analytical formulations, their own close correspondence of results lends added credence to the value of analytical predictions

  16. Measurement of the Λ→n+γ branching ratio

    International Nuclear Information System (INIS)

    Noble, A.J.; Larson, K.D.; Bassalleck, B.; Fickinger, W.J.; Hall, J.R.; Hallin, A.L.; Hasinoff, M.D.; Horvath, D.; Lowe, J.; McIntyre, E.K.; Measday, D.F.; Miller, J.P.; Roberts, B.L.; Robinson, D.K.; Sakitt, M.; Salomon, M.; Waltham, C.E.; Warner, T.M.; Whitehouse, D.A.; Wolfe, D.M.

    1992-01-01

    The branching ratio for the Λ weak radiative decay has been measured to be B(Λ→n+γ)/(Λ→anything) =[1.78±0.24(stat)± 0.16 0.14 (syst)]x10 -3 . A low-energy kaon beam was used to produce the Λ hyperons via the reaction K - +p→Λ+π 0 at rest. Photons from the signal channel and π 0 decay were detected with a NaI(Tl) array. The final spectrum contains 287 events after background subtraction, an order of magnitude more events than from the only previous measurement

  17. Enhancement of the Signal-to-Noise Ratio in Sonic Logging Waveforms by Seismic Interferometry

    KAUST Repository

    Aldawood, Ali

    2012-04-01

    Sonic logs are essential tools for reliably identifying interval velocities which, in turn, are used in many seismic processes. One problem that arises, while logging, is irregularities due to washout zones along the borehole surfaces that scatters the transmitted energy and hence weakens the signal recorded at the receivers. To alleviate this problem, I have extended the theory of super-virtual refraction interferometry to enhance the signal-to-noise ratio (SNR) sonic waveforms. Tests on synthetic and real data show noticeable signal-to-noise ratio (SNR) enhancements of refracted P-wave arrivals in the sonic waveforms. The theory of super-virtual interferometric stacking is composed of two redatuming steps followed by a stacking procedure. The first redatuming procedure is of correlation type, where traces are correlated together to get virtual traces with the sources datumed to the refractor. The second datuming step is of convolution type, where traces are convolved together to dedatum the sources back to their original positions. The stacking procedure following each step enhances the signal to noise ratio of the refracted P-wave first arrivals. Datuming with correlation and convolution of traces introduces severe artifacts denoted as correlation artifacts in super-virtual data. To overcome this problem, I replace the datuming with correlation step by datuming with deconvolution. Although the former datuming method is more robust, the latter one reduces the artifacts significantly. Moreover, deconvolution can be a noise amplifier which is why a regularization term is utilized, rendering the datuming with deconvolution more stable. Tests of datuming with deconvolution instead of correlation with synthetic and real data examples show significant reduction of these artifacts. This is especially true when compared with the conventional way of applying the super-virtual refraction interferometry method.

  18. Validation of a dual-isotope plasma ratio method for measurement of cholesterol absorption in rats

    International Nuclear Information System (INIS)

    Zilversmit, D.B.; Hughes, L.B.

    1974-01-01

    Several methods for measuring cholesterol absorption in the rat have been compared. After administration of an oral dose of labeled cholesterol ( 14 C or 3 H) and an intravenous dose of colloidal labeled cholesterol ( 3 H or 14 C) the ratio of the two labels in plasma or whole blood 48 hr or more after dosing compared closely to the ratio of areas under the respective specific activity-time curves. The area ratio method is independent of a time lag between the appearance of oral and intravenous label in the bloodstream. Both measures of cholesterol absorption agree fairly well with a method based on measuring the unabsorbed dietary cholesterol in a pooled fecal sample. The plasma isotope ratio method gave more reproducible results than the fecal collection method when the measurement was repeated in the same animals 5 days after the first measurement. Cholesterol absorption was overestimated by the use of Tween 20-solubilized labeled cholesterol for the intravenous dose. The plasma disappearance curves of injected labeled colloidal cholesterol and cholesterol-labeled chylomicrons infused intravenously over a 3.5-h period in the same animal coincided within experimental error from the first day until 75 days after injection. The plasma isotope ratio method for cholesterol absorption gave the same results in rats practicing coprophagy as in those in which this practice was prevented. The addition of sulfaguanidine to the diet lowered cholesterol absorption as measured by the plasma isotope ratio to the same degree as that measured by the fecal collection method. (U.S.)

  19. Raman scattering method and apparatus for measuring isotope ratios and isotopic abundances

    International Nuclear Information System (INIS)

    Harney, R.C.; Bloom, S.D.

    1978-01-01

    Raman scattering is used to measure isotope ratios and/or isotopic abundances. A beam of quasi-monochromatic photons is directed onto the sample to be analyzed, and the resulting Raman-scattered photons are detected and counted for each isotopic species of interest. These photon counts are treated mathematically to yield the desired isotope ratios or isotopic abundances

  20. Platinum stable isotope ratio measurements by double-spike multiple collector ICPMS

    DEFF Research Database (Denmark)

    Creech, John; Baker, Joel; Handler, Monica

    2013-01-01

    We present a new technique for the precise determination of platinum (Pt) stable isotope ratios by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using two different Pt double-spikes ( Pt-Pt and Pt-Pt). Results are expressed relative to the IRMM-010 Pt isotope standard......) can be obtained on Pt stable isotope ratios with either double-spike. Elemental doping tests reveal that double-spike corrected Pt stable isotope ratios are insensitive to the presence of relatively high (up to 10%) levels of matrix elements, although the Pt-Pt double-spike is affected by an isobaric...... = 7.308%) results in a redefined Pt atomic weight of 195.08395 ± 0.00068. Using our technique we have measured small, reproducible and statistically significant offsets in Pt stable isotope ratios between different Pt element standards and the IRMM-010 standard, which potentially indicates...

  1. Measurement of the atmospheric muon charge ratio with the OPERA detector

    OpenAIRE

    Mauri, Nicoletta

    2011-01-01

    The atmospheric muon charge ratio, defined as the number of positive over negative charged muons, is an interesting quantity for the study of high energy hadronic interactions in atmosphere and the nature of the primary cosmic rays. The measurement of the charge ratio in the TeV muon energy range allows to study the hadronic interactions in kinematic regions not yet explored at accelerators. The OPERA experiment is a hybrid electronic detector/emulsion apparatus, located in the undergroun...

  2. Microphone Handling Noise: Measurements of Perceptual Threshold and Effects on Audio Quality.

    Directory of Open Access Journals (Sweden)

    Paul Kendrick

    Full Text Available A psychoacoustic experiment was carried out to test the effects of microphone handling noise on perceived audio quality. Handling noise is a problem affecting both amateurs using their smartphones and cameras, as well as professionals using separate microphones and digital recorders. The noises used for the tests were measured from a variety of devices, including smartphones, laptops and handheld microphones. The signal features that characterise these noises are analysed and presented. The sounds include various types of transient, impact noises created by tapping or knocking devices, as well as more sustained sounds caused by rubbing. During the perceptual tests, listeners auditioned speech podcasts and were asked to rate the degradation of any unwanted sounds they heard. A representative design test methodology was developed that tried to encourage everyday rather than analytical listening. Signal-to-noise ratio (SNR of the handling noise events was shown to be the best predictor of quality degradation. Other factors such as noise type or background noise in the listening environment did not significantly affect quality ratings. Podcast, microphone type and reproduction equipment were found to be significant but only to a small extent. A model allowing the prediction of degradation from the SNR is presented. The SNR threshold at which 50% of subjects noticed handling noise was found to be 4.2 ± 0.6 dBA. The results from this work are important for the understanding of our perception of impact sound and resonant noises in recordings, and will inform the future development of an automated predictor of quality for handling noise.

  3. Isotope ratio measurements of uranium by LA-HR-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Marin, Rafael C.; Sarkis, Jorge E.S., E-mail: rafael.marin@usp.b, E-mail: jesarkis@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This work describes the utilization of Laser Ablation High Resolution Inductively Mass Spectrometry (LA-HR-ICP-MS) technique for the determination of uranium isotope composition in a UO{sub 2} pellet (CRM -125A) supplied and certified by the New Brunswick Laboratory (NBL). To carry out the adjustments of the parameters was used a glass standard NIST 610, supplied and certified by National Institute of Standards and Technology (NIST). The precision of the measurements were improved by adjusting the following parameters: RF power, laser beam diameter, defocusing of laser beam, laser energy, laser energy-density, auxiliary gas and sample gas. The measurements were performed on a continuous ablation with low energy density and defocusing, which demonstrated to be the optimum to reach the best signal stability. Isotope ratios, {sup 234}U/{sup 238}U, {sup 235}U/{sup 238}U and {sup 236}U/{sup 238}U were measured, reaching relative standard deviations (RSD) from 1.55% to 7.60%. The parameters which caused the greatest impact in order to improve the signal stability were RF power, defocusing and laser beam diameter. The results presented by the measurements revealed that the Laser ablation ICP-MS technique offers a rapid and accurate way to perform uranium isotope ratios without any sample preparation, since it allows carrying out the measurements straight on the sample, besides to preserve the testimony that is very important for safeguards and nuclear forensics purposes. (author)

  4. Bellows for the DEBENE SNR-Project

    International Nuclear Information System (INIS)

    Warmerdam, C.P.; Lievense, K.

    1980-01-01

    Liquid Metal cooled Fast Breeder Reactors (LMFBR) are designed to work at temperature levels up to 600 deg C. The components and piping systems are submitted to changing temperature fields varying between room temperature and temperatures in operational, incidental or accidental conditions. Bellows are generally used to introduce a higher flexibility of piping systems and for the leak tight connection of components with relative displacements. The total piping length of a loop type LMFBR is principally determined by thermal expansion requirements. The application of bellows could reduce piping length and building volume. In certain cases a reduction of the nozzle loads can be realized. In cooperation between Neratoom and TNO a feasibility study concerning the applicability of bellows as compensating elements in a primary piping system of a loop type LMFBR has been studied. Different configurations are compared with each other. TNO has performed dimension calculations, with the criteria from the ASME Code Section III and Code Case N-47, as guideline. In this paper a review of the results of these calculations will be given. The development of the expansion bellows, in the shells of the SNR 300 straight tube steam generators to compensate the difference in the thermal expansion between shell and tube bundle, has been concluded by a series of full scale fatigue tests under design conditions, except for the sodium environment. In this paper a summary is given of these tests and of the procedure used to prove that the bellows in the actual steam generators will withstand the design fatigue loads. (This is the LMFBR project of the DEBENE states: Federal Republic of Germany, Belgium and The Netherlands)

  5. Measurement of the proton form factor ratio at low momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Moshe [Hebrew Univ. of Jerusalem (Israel)

    2016-08-01

    Experiment E08-007-II measured the proton elastic form factor ratio μGE=GM in the momentum transfer range of Q2 ~ 0.02 - 0.08 GeV2, the lowest ever measured by polarization transfer techniques. The experiment was performed at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia, USA during 2012. A polarized electron beam with energies of 1.1, 1.7, and 2.2 GeV was elastically scattered off a polarized solid NH3 target. The asymmetries between the cross section of positive and negative helicity states of the beam were determined. These asymmetries can be used to determine the form factor ratio. In this thesis, we present the asymmetry analysis of the experiment, discuss the main challenges and show preliminary results for part of the data. Preliminary asymmetries indicate an increase in the form factor ratio above unity. However, a complete analysis is required before any conclusion can be made. Further analysis is ongoing, and final asymmetry results and form factor extraction is expected during 2017. We also present first results for 14N asymmetries for elastic and quasi-elastic scattering. The measured asymmetries are in agreement with the shell model approximation, within the low accuracy of the measurement. A change in the asymmetry sign between the elastic and the quasi-elastic processes is seen, and should motivate further theoretical studies. These experimental asymmetries will also be useful for systematic studies of other experiments using polarized NH3 targets.

  6. Determination of hydrogen/deuterium ratio with neutron measurements on MAST

    Energy Technology Data Exchange (ETDEWEB)

    Klimek, I., E-mail: iwona.klimek@physics.uu.se; Cecconello, M.; Ericsson, G. [Department of Physics and Astronomy, Uppsala University, Uppsala (Sweden); Sharapov, S. E.; Harrison, J. [CCFE, Culham Science Centre, Abingdon (United Kingdom)

    2014-11-15

    On MAST, compressional Alfvén eigenmodes can be destabilized by the presence of a sufficiently large population of energetic particles in the plasma. This dependence was studied in a series of very similar discharges in which increasing amounts of hydrogen were puffed into a deuterium plasma. A simple method to estimate the isotopic ratio n{sub H}/n{sub D} using neutron emission measurements is here described. The inferred isotopic ratio ranged from 0.0 to 0.6 and no experimental indication of changes in radial profile of n{sub H}/n{sub D} were observed. These findings are confirmed by TRANSP/NUBEAM simulations of the neutron emission.

  7. Prediction of topographic and bathymetric measurement performance of airborne low-SNR lidar systems

    Science.gov (United States)

    Cossio, Tristan

    Low signal-to-noise ratio (LSNR) lidar (light detection and ranging) is an alternative paradigm to traditional lidar based on the detection of return signals at the single photoelectron level. The objective of this work was to predict low altitude (600 m) LSNR lidar system performance with regards to elevation measurement and target detection capability in topographic (dry land) and bathymetric (shallow water) scenarios. A modular numerical sensor model has been developed to provide data for further analysis due to the dearth of operational low altitude LSNR lidar systems. This simulator tool is described in detail, with consideration given to atmospheric effects, surface conditions, and the effects of laser phenomenology. Measurement performance analysis of the simulated topographic data showed results comparable to commercially available lidar systems, with a standard deviation of less than 12 cm for calculated elevation values. Bathymetric results, although dependent largely on water turbidity, were indicative of meter-scale horizontal data spacing for sea depths less than 5 m. The high prevalence of noise in LSNR lidar data introduces significant difficulties in data analysis. Novel algorithms to reduce noise are described, with particular focus on their integration into an end-to-end target detection classifier for both dry and submerged targets (cube blocks, 0.5 m to 1.0 m on a side). The key characteristic exploited to discriminate signal and noise is the temporal coherence of signal events versus the random distribution of noise events. Target detection performance over dry earth was observed to be robust, reliably detecting over 90% of targets with a minimal false alarm rate. Comparable results were observed in waters of high clarity, where the investigated system was generally able to detect more than 70% of targets to a depth of 5 m. The results of the study show that CATS, the University of Florida's LSNR lidar prototype, is capable of high fidelity

  8. First measurement of the Omega /sup -/ decay branching ratios

    CERN Document Server

    Bourquin, M; Chatelus, Y; Chollet, J C; Degré, A; Froidevaux, D; Fyfe, A R; Gaillard, J M; Gee, C N P; Gibson, W M; Igo-Kemenes, P; Jeffreys, P W; Merkel, B; Morand, R; Plothow, H; Repellin, J P; Saunders, B J; Sauvage, G; Schiby, B; Siebert, H W; Smith, V J; Streit, K P; Strub, R; Thresher, J J; Tovey, Stuart N

    1979-01-01

    In an experiment in the CERN-SPS charged-hyperon beam, the main Omega /sup -/ decay branching ratios have been measured to be Gamma ( Omega /sup -/ to Lambda K/sup -/)/ Gamma (all)=0.686+or-0.013, Gamma ( Omega /sup -/ to Xi /sup 0/ pi /sup -/)/ Gamma (all) =0.234+or-0.013, Gamma ( Omega /sup -/ to Xi /sup -/ pi /sup 0/)/ Gamma (all)=0.080+or-0.008. The relative branching ratio of the two Xi pi modes provides a test of the Delta I=1/2 rule in decuplet-octet transitions. A search has also been made for the rare decay modes Omega /sup -/ to Lambda pi /sup -/, Omega /sup -/ to Xi /sup -/ gamma , Omega /sup -/ to Xi /sup -/ pi /sup +/ pi /sup -/ and Omega /sup -/ to Xi /sup 0/e/sup -/ nu . (6 refs).

  9. Measurement of transparency ratios for protons from short-range correlated pairs

    Science.gov (United States)

    Hen, O.; Hakobyan, H.; Shneor, R.; Piasetzky, E.; Weinstein, L. B.; Brooks, W. K.; May-Tal Beck, S.; Gilad, S.; Korover, I.; Beck, A.; Adhikari, K. P.; Aghasyan, M.; Amaryan, M. J.; Anefalos Pereira, S.; Arrington, J. R.; Baghdasaryan, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fleming, J. A.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hafidi, K.; Harrison, N.; Heddle, D.; Hicks, K.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joo, K.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Klein, F. J.; Koirala, S.; Kubarovsky, A.; Kubarovsky, V.; Kuhn, S. E.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Martinez, D.; Mayer, M.; McKinnon, B.; Mineeva, T.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Munevar, E.; Munoz Camacho, C.; Mustapha, B.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Phelps, E.; Phillips, J. J.; Pisano, S.; Pivnyuk, N.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Puckett, A. J. R.; Raue, B. A.; Rimal, D.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tian, Ye; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vlassov, A.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zheng, X.; Zonta, I.

    2013-05-01

    Nuclear transparency, Tp (A), is a measure of the average probability for a struck proton to escape the nucleus without significant re-interaction. Previously, nuclear transparencies were extracted for quasi-elastic A (e ,e‧ p) knockout of protons with momentum below the Fermi momentum, where the spectral functions are well known. In this Letter we extract a novel observable, the transparency ratio, Tp (A) /Tp(12 C), for knockout of high-missing-momentum protons from the breakup of short-range correlated pairs (2N-SRC) in Al, Fe and Pb nuclei relative to C. The ratios were measured at momentum transfer Q2 ⩾ 1.5(GeV /c) 2 and xB ⩾ 1.2 where the reaction is expected to be dominated by electron scattering from 2N-SRC. The transparency ratios of the knocked-out protons coming from 2N-SRC breakup are 20-30% lower than those of previous results for low missing momentum. They agree with Glauber calculations and agree with renormalization of the previously published transparencies as proposed by recent theoretical investigations. The new transparencies scale as A - 1 / 3, which is consistent with dominance of scattering from nucleons at the nuclear surface.

  10. A New Laser Based Approach for Measuring Atmospheric Greenhouse Gases

    Directory of Open Access Journals (Sweden)

    Jeremy Dobler

    2013-11-01

    Full Text Available In 2012, we developed a proof-of-concept system for a new open-path laser absorption spectrometer concept for measuring atmospheric CO2. The measurement approach utilizes high-reliability all-fiber-based, continuous-wave laser technology, along with a unique all-digital lock-in amplifier method that, together, enables simultaneous transmission and reception of multiple fixed wavelengths of light. This new technique, which utilizes very little transmitted energy relative to conventional lidar systems, provides high signal-to-noise (SNR measurements, even in the presence of a large background signal. This proof-of-concept system, tested in both a laboratory environment and a limited number of field experiments over path lengths of 680 m and 1,600 m, demonstrated SNR values >1,000 for received signals of ~18 picoWatts averaged over 60 s. A SNR of 1,000 is equivalent to a measurement precision of ±0.001 or ~0.4 ppmv. The measurement method is expected to provide new capability for automated monitoring of greenhouse gas at fixed sites, such as carbon sequestration facilities, volcanoes, the short- and long-term assessment of urban plumes, and other similar applications. In addition, this concept enables active measurements of column amounts from a geosynchronous orbit for a network of ground-based receivers/stations that would complement other current and planned space-based measurement capabilities.

  11. High-precision branching ratio measurement for the superallowed β+ emitter 62Ga

    International Nuclear Information System (INIS)

    Finlay, P.E.J.

    2007-01-01

    A high-precision branching ratio measurement for the superallowed β + decay of 62 Ga was performed at the Isotope Separator and Accelerator radioactive ion beam facility. An array of 20 high-purity germanium detectors known as the 8π spectrometer was employed to detect the rays emitted following the Gamow-Teller and non-analog Fermi decays of 62 Ga, while the plastic scintillator array known as SCEPTAR was used to detect the emitted particles. A total of 32 γ rays were identified, establishing the superallowed branching ratio to be 99:859(8)%. Combined with the most recent half-life and Q-value measurements for 62 Ga, this branching ratio yields an ft-value of 3074.3 ± 1.1 s. Comparisons between the superallowed ft-value determined in this work and the world average Ft-bar are made, providing a benchmark for the refinement of theoretical models used to describe isospin-symmetry breaking in A ≥ 62 nuclei. (author)

  12. Absolute measurement of the isotopic ratio of a water sample with very low deuterium content

    International Nuclear Information System (INIS)

    Hagemann, R.; Nief, G.; Roth, E.

    1968-01-01

    The presence of H 3+ ions which are indistinguishable from HD + ions presents the principal difficulty encountered in the measurement of isotopic ratios of water samples with very low deuterium contents using a mass spectrometer. Thus, when the sample contains no deuterium, the mass spectrometer does not indicate zero. By producing, in situ, from the sample to be measured, water vapor with an isotopic ratio very close to zero using a small distilling column, this difficulty is overcome. This column, its operating parameters, as well as the way in which the measurements are made are described. An arrangement is employed in which the isotopic ratios can be measured with a sensitivity better than 0.01 x 10 -6 . The method is applied to the determination of the isotopic ratios of three low deuterium content water samples. The results obtained permit one to assign to the sample with the lowest deuterium content an absolute value equal to 1.71 ± 0.03 ppm. This water sample is a primary standard from which is determined the isotopic ratio of a natural water sample which serves as the laboratory standard. (author) [fr

  13. Design and operational behaviour of the SNR-reactor fuel element structure

    International Nuclear Information System (INIS)

    Dietz, W.; Toebbe, H.

    1985-01-01

    The fuel element and core concept of a fast breeder reactor is described by the example of the SNR 300 (1st core), and the requirements made on the fuel elements with respect to burnup and neutron dose are listed for existing and projected plants. Irradiation experiments carried out and operational experience gained with fuel elements show that the residence time of the fuel elements is influenced mainly by the stability of shape of the fuel element components. The requirements made with reference to neutron loading for future advanced high-performance fuel elements can not be anticipated from the present state of experience. Besides optimization of fuel element design and checking-out of the limits of operation by PFADFINDERELEMENTE elements, R and D work for the improvement of fuel element materials is also necessary. (orig.) [de

  14. KiDS-450: cosmological constraints from weak lensing peak statistics - I. Inference from analytical prediction of high signal-to-noise ratio convergence peaks

    Science.gov (United States)

    Shan, HuanYuan; Liu, Xiangkun; Hildebrandt, Hendrik; Pan, Chuzhong; Martinet, Nicolas; Fan, Zuhui; Schneider, Peter; Asgari, Marika; Harnois-Déraps, Joachim; Hoekstra, Henk; Wright, Angus; Dietrich, Jörg P.; Erben, Thomas; Getman, Fedor; Grado, Aniello; Heymans, Catherine; Klaes, Dominik; Kuijken, Konrad; Merten, Julian; Puddu, Emanuella; Radovich, Mario; Wang, Qiao

    2018-02-01

    This paper is the first of a series of papers constraining cosmological parameters with weak lensing peak statistics using ˜ 450 deg2 of imaging data from the Kilo Degree Survey (KiDS-450). We measure high signal-to-noise ratio (SNR: ν) weak lensing convergence peaks in the range of 3 < ν < 5, and employ theoretical models to derive expected values. These models are validated using a suite of simulations. We take into account two major systematic effects, the boost factor and the effect of baryons on the mass-concentration relation of dark matter haloes. In addition, we investigate the impacts of other potential astrophysical systematics including the projection effects of large-scale structures, intrinsic galaxy alignments, as well as residual measurement uncertainties in the shear and redshift calibration. Assuming a flat Λ cold dark matter model, we find constraints for S_8=σ _8(Ω _m/0.3)^{0.5}=0.746^{+0.046}_{-0.107} according to the degeneracy direction of the cosmic shear analysis and Σ _8=σ _8(Ω _m/0.3)^{0.38}=0.696^{+0.048}_{-0.050} based on the derived degeneracy direction of our high-SNR peak statistics. The difference between the power index of S8 and in Σ8 indicates that combining cosmic shear with peak statistics has the potential to break the degeneracy in σ8 and Ωm. Our results are consistent with the cosmic shear tomographic correlation analysis of the same data set and ˜2σ lower than the Planck 2016 results.

  15. Technical note: Using distributed temperature sensing for Bowen ratio evaporation measurements

    Science.gov (United States)

    Schilperoort, Bart; Coenders-Gerrits, Miriam; Luxemburg, Willem; Jiménez Rodríguez, César; Cisneros Vaca, César; Savenije, Hubert

    2018-01-01

    Rapid improvements in the precision and spatial resolution of distributed temperature sensing (DTS) technology now allow its use in hydrological and atmospheric sciences. Introduced by ) is the use of DTS for measuring the Bowen ratio (BR-DTS), to estimate the sensible and latent heat flux. The Bowen ratio is derived from DTS-measured vertical profiles of the air temperature and wet-bulb temperature. However, in previous research the measured temperatures were not validated, and the cables were not shielded from solar radiation. Additionally, the BR-DTS method has not been tested above a forest before, where temperature gradients are small and energy storage in the air column becomes important. In this paper the accuracy of the wet-bulb and air temperature measurements of the DTS are verified, and the resulting Bowen ratio and heat fluxes are compared to eddy covariance data. The performance of BR-DTS was tested on a 46 m high tower in a mixed forest in the centre of the Netherlands in August 2016. The average tree height is 26 to 30 m, and the temperatures are measured below, in, and above the canopy. Using the vertical temperature profiles the storage of latent and sensible heat in the air column was calculated. We found a significant effect of solar radiation on the temperature measurements, leading to a deviation of up to 3 K. By installing screens, the error caused by sunlight is reduced to under 1 K. Wind speed seems to have a minimal effect on the measured wet-bulb temperature, both below and above the canopy. After a simple quality control, the Bowen ratio measured by DTS correlates well with eddy covariance (EC) estimates (r2 = 0.59). The average energy balance closure between BR-DTS and EC is good, with a mean underestimation of 3.4 W m-2 by the BR-DTS method. However, during daytime the BR-DTS method overestimates the available energy, and during night-time the BR-DTS method estimates the available energy to be more negative. This difference could be

  16. Statistical x-ray computed tomography imaging from photon-starved measurements

    Science.gov (United States)

    Chang, Zhiqian; Zhang, Ruoqiao; Thibault, Jean-Baptiste; Sauer, Ken; Bouman, Charles

    2013-03-01

    Dose reduction in clinical X-ray computed tomography (CT) causes low signal-to-noise ratio (SNR) in photonsparse situations. Statistical iterative reconstruction algorithms have the advantage of retaining image quality while reducing input dosage, but they meet their limits of practicality when significant portions of the sinogram near photon starvation. The corruption of electronic noise leads to measured photon counts taking on negative values, posing a problem for the log() operation in preprocessing of data. In this paper, we propose two categories of projection correction methods: an adaptive denoising filter and Bayesian inference. The denoising filter is easy to implement and preserves local statistics, but it introduces correlation between channels and may affect image resolution. Bayesian inference is a point-wise estimation based on measurements and prior information. Both approaches help improve diagnostic image quality at dramatically reduced dosage.

  17. Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Young Yiul; Park, Seon Yang; Lee, Myung Chul; Choi, Sang Jae; Cho, Bo Youn; Choe, Kang Won; Koh, Chang Soon

    1982-01-01

    To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio (SIS Ratio) by region of interest (ROI) method using 99m Tc-methylene diphosphonate. The observed results were as follows:1) Using ROI method, the SIS ratios for the control group of 65 persons were 1.05±0.08 (left) and 1.06±0.07 (right) which were narrower in range than those of slice method (mean±S.D.) 2) The effects of age, gender and laterality on SIS ratio were not significant. 3) In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4) In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who bad no evidence of sacroiliitis clinically was within normal limit. 5) In 6 patients with ankylosing spondylitis in both sacroiliac joints, q whose pelvis A-P X-ray findings showed severe sclerotic change of sacroiliac pints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6) 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded the quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  18. PIC simulations of magnetic field production by cosmic rays drifting upstream of SNR shocks

    International Nuclear Information System (INIS)

    Pohl, M.

    2008-01-01

    Turbulent magnetic-field amplification appears to operate near the forward shocks of young shell-type SNR. I review the observational constraints on the spatial distribution and amplitude of amplified magnetic field in this environment. I also present new PIC simulations of magnetic-field growth due to streaming cosmic rays. While the nature of the initial linear instability is largely determined by the choice of simulation parameters, the saturation always involves changing the bulk motion of cosmic rays and background plasma, which limits the field growth to amplitudes of a few times that of the homogeneous magnetic field. (author)

  19. The measurement and interpretation of Ne VII spectral line intensity ratios

    International Nuclear Information System (INIS)

    Lang, J.

    1983-03-01

    Results are presented for the measurement, using the branching ratios calibration method, of the spectral intensities of Ne VII lines emitted from a theta-pinch plasma whose electron temperature and density have been found by laser scattering and alternate techniques. (author)

  20. Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages

    International Nuclear Information System (INIS)

    Sandborg, Michael; Tingberg, Anders; Ullman, Gustaf; Dance, David R.; Alm Carlsson, Gudrun

    2006-01-01

    The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography

  1. Predicting speech intelligibility based on the signal-to-noise envelope power ratio after modulation-frequency selective processing

    DEFF Research Database (Denmark)

    Jørgensen, Søren; Dau, Torsten

    2011-01-01

    A model for predicting the intelligibility of processed noisy speech is proposed. The speech-based envelope power spectrum model has a similar structure as the model of Ewert and Dau [(2000). J. Acoust. Soc. Am. 108, 1181-1196], developed to account for modulation detection and masking data. The ...... process provides a key measure of speech intelligibility. © 2011 Acoustical Society of America.......A model for predicting the intelligibility of processed noisy speech is proposed. The speech-based envelope power spectrum model has a similar structure as the model of Ewert and Dau [(2000). J. Acoust. Soc. Am. 108, 1181-1196], developed to account for modulation detection and masking data....... The model estimates the speech-to-noise envelope power ratio, SNR env, at the output of a modulation filterbank and relates this metric to speech intelligibility using the concept of an ideal observer. Predictions were compared to data on the intelligibility of speech presented in stationary speech...

  2. Enhancing Sensor Network Data Quality via Collaborated Circuit and Network Operations

    Directory of Open Access Journals (Sweden)

    Lucas Vespa

    2013-04-01

    Full Text Available In many applications, the quality of data gathered by sensor networks is directly related to the signal-to-noise ratio (SNR of the sensor data being transmitted in the networks. Different from the SNR that is often used in measuring the quality of communication links, the SNR used in this work measures how accurately the data in the network packets represent the physical parameters being sensed. Hence, the signal here refers to the physical parameters that are being monitored by sensor networks; the noise is due to environmental interference and circuit noises at sensor nodes, and packet loss during network transmission. While issues affecting SNR at sensor nodes have been intensively investigated, the impact of network packet loss on data SNR has not attracted significant attention in sensor network design. This paper investigates the impact of packet loss on sensor network data SNR and shows that data SNR is dramatically affected by network packet loss. A data quality metric, based on data SNR, is developed and a cross-layer adaptive scheme is presented to minimize data quality degradation in congested sensor networks. The proposed scheme consists of adaptive downsampling and bit truncation at sensor nodes and intelligent traffic management techniques at the network level. Simulation results are presented to demonstrate the validity and effectiveness of the proposed techniques.

  3. Simulation and Measurement of Neuroelectrodes' Characteristics with Integrated High Aspect Ratio Nano Structures

    Directory of Open Access Journals (Sweden)

    Christoph Nick

    2015-07-01

    Full Text Available Improving the interface between electrodes and neurons has been the focus of research for the last decade. Neuroelectrodes should show small geometrical surface area and low impedance for measuring and high charge injection capacities for stimulation. Increasing the electrochemically active surface area by using nanoporous electrode material or by integrating nanostructures onto planar electrodes is a common approach to improve this interface. In this paper a simulation approach for neuro electrodes' characteristics with integrated high aspect ratio nano structures based on a point-contact-model is presented. The results are compared with experimental findings conducted with real nanostructured microelectrodes. In particular, effects of carbon nanotubes and gold nanowires integrated onto microelectrodes are described. Simulated and measured impedance properties are presented and its effects onto the transfer function between the neural membrane potential and the amplifier output signal are studied based on the point-contact-model. Simulations show, in good agreement with experimental results, that electrode impedances can be dramatically reduced by the integration of high aspect ratio nanostructures such as gold nanowires and carbon nanotubes. This lowers thermal noise and improves the signal-to-noise ratio for measuring electrodes. It also may increase the adhesion of cells to the substrate and thus increase measurable signal amplitudes.

  4. Optimization of signal-to-noise ratio for wireless light-emitting diode communication in modern lighting layouts

    Science.gov (United States)

    Azizan, Luqman A.; Ab-Rahman, Mohammad S.; Hassan, Mazen R.; Bakar, A. Ashrif A.; Nordin, Rosdiadee

    2014-04-01

    White light-emitting diodes (LEDs) are predicted to be widely used in domestic applications in the future, because they are becoming widespread in commercial lighting applications. The ability of LEDs to be modulated at high speeds offers the possibility of using them as sources for communication instead of illumination. The growing interest in using these devices for both illumination and communication requires attention to combine this technology with modern lighting layouts. A dual-function system is applied to three models of modern lighting layouts: the hybrid corner lighting layout (HCLL), the hybrid wall lighting layout (HWLL), and the hybrid edge lighting layout (HELL). Based on the analysis, the relationship between the space adversity and the signal-to-noise ratio (SNR) performance is demonstrated for each model. The key factor that affects the SNR performance of visible light communication is the reliance on the design parameter that is related to the number and position of LED lights. The model of HWLL is chosen as the best layout, since 61% of the office area is considered as an excellent communication area and the difference between the area classification, Δp, is 22%. Thus, this system is applicable to modern lighting layouts.

  5. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    International Nuclear Information System (INIS)

    Mauri, N.; Sioli, M.

    2012-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio R μ =N μ + /N μ − in the TeV energy region. R μ is shown as a function of the “vertical surface energy” E μ cosθ. A fit to a simplified model of muon production in atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  6. Measurement of the tau lifetime and leptonic branching ratios in L3

    International Nuclear Information System (INIS)

    Garcia-Abia, P.

    2001-01-01

    Using data collected with the L3 detector near the Z resonance corresponding to an integrated luminosity of 150 pb -1 the lifetime of the tau lepton is measured to be τ τ = 293.2 ± 2.0(stat.) ± 1.5(sys.) fs, and the branching ratios of the tau lepton into electron and muon are measured to be B(τ → eν-bar e ν τ ) = (17.806 ± 0.104 (stat.)±0.076(sys.))% and B(τ → μν-bar μ ν τ ) = (17.342 ± 0.110 (stat.)±0.067(sys.))%, respectively. From these results the ratio of the charged current coupling constants g μ /g e , g τ /g e and g τ /g μ are determined and support the lepton universality hypothesis. The Fermi-constant and the coupling constant of the strong interaction at the tau mass are obtained from these measurements

  7. Technical note: using Distributed Temperature Sensing for Bowen ratio evaporation measurements

    NARCIS (Netherlands)

    Schilperoort, B.; Coenders, Miriam; Luxemburg, W.M.J.; Jimenez Rodriguez, C.D.; Cisneros Vaca2, C.; Savenije, Hubert

    2017-01-01

    Rapid improvements in the precision and spatial resolution of Distributed Temperature Sensing (DTS) technology now allows its use in hydrological and atmospheric sciences. Introduced by Euser [Hydrol. Earth Syst. Sci., 18, 2021–2032 (2014)] is the use of DTS for measuring the Bowen ratio (BR-DTS),

  8. Strain ratio measurement of femoral cartilage by real-time elastosonography: preliminary results

    International Nuclear Information System (INIS)

    Ipek, Ali; Unal, Ozlem; Kartal, Merve Gulbiz; Arslan, Halil; Isik, Cetin; Bozkurt, Murat

    2015-01-01

    The purpose of this study was to evaluate strain ratio measurement of femoral cartilage using real-time elastosonography. Twenty-five patients with femoral cartilage pathology on MRI (study group) were prospectively compared with 25 subjects with normal findings on MRI (control group) using real-time elastosonography. Strain ratio measurements of pathologic and normal cartilage were performed and compared, both within the study group and between the two groups. Elastosonography colour-scale coding showed a colour change from blue to red in pathologic cartilage and only blue colour-coding in normal cartilage. In the study group, the median strain ratio was higher in pathologic cartilage areas compared to normal areas (median, 1.49 [interquartile range, 0.80-2.53] vs. median, 0.01 [interquartile range, 0.01-0.01], p < 0.001, respectively). The median strain ratio of the control group was 0.01 (interquartile range, 0.01-0.01), and there was no significant difference compared to normal areas of the study group. There was, however, a significant difference between the control group cartilage and pathologic cartilage of the study group (p < 0.001). Elastosonography may be an effective, easily accessible, and relatively simple tool to demonstrate pathologic cartilage and to differentiate it from normal cartilage in the absence of advanced imaging facility such as MRI. (orig.)

  9. An approach for measuring the {sup 129}I/{sup 127}I ratio in fish samples

    Energy Technology Data Exchange (ETDEWEB)

    Kusuno, Haruka, E-mail: kusuno@um.u-tokyo.ac.jp [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Matsuzaki, Hiroyuki [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Nagata, Toshi; Miyairi, Yosuke; Yokoyama, Yusuke [Atmosphere and Ocean Research Institute, The University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa-shi, Chiba 277-8564 (Japan); Ohkouchi, Naohiko [Japan Agency for Marine-Earth Science and Technology, 2-15, Natsushima-cho, Yokosuka-city, Kanagawa 237-0061 (Japan)

    2015-10-15

    The {sup 129}I/{sup 127}I ratio in marine fish samples was measured employing accelerator mass spectrometry. The measurement was successful because of the low experimental background of {sup 129}I. Pyrohydrolysis was applied to extract iodine from fish samples. The experimental background of pyrohydrolysis was checked carefully and evaluated as 10{sup 4}–10{sup 5} atoms {sup 129}I/combustion. The methodology employed in the present study thus required only 0.05–0.2 g of dried fish samples. The methodology was then applied to obtain the {sup 129}I/{sup 127}I ratio of marine fish samples collected from the Western Pacific Ocean as (0.63–1.2) × 10{sup −10}. These values were similar to the ratio for the surface seawater collected at the same station, 0.4 × 10{sup −10}. The {sup 129}I/{sup 127}I ratio of IAEA-414, which was a mix of fish from the Irish Sea and the North Sea, was also measured and determined as 1.82 × 10{sup −7}. Consequently, fish from the Western Pacific Ocean and the North Sea were distinguished by their {sup 129}I/{sup 127}I ratios. The {sup 129}I/{sup 127}I ratio is thus a direct indicator of the area of habitat of fish.

  10. Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU

    Directory of Open Access Journals (Sweden)

    Deb Kumar Mojumder

    2015-01-01

    Full Text Available Introduction: Measurement of static pupillary size in the ICU is of importance in cases of acutely expanding intracranial mass lesions. The inaccuracies with subjective assessment of pupillary size by medical personnel preclude its use in emergent neurological situations. Objective: To determine if the ratio of pupil to limbus diameter (PLD ratio measured by a two-box method is a reliable measure of pupil size for detecting early anisocoria and measuring pupillary changes. Materials and Methods: The PLD ratio was defined as the ratio of the pupillary diameter measured at a para-horizontal axial plane with the limbus diameter measured at the same or parallel axial plane. A two-box method was used to estimate the diameters of imaged pupils. Eyes were imaged using an iPhone 4S cellphone camera. Background illumination was measured and kept constant. The pupils of a 78-year-old woman, who presented with a large intra-axial parenchymal hemorrhage, were imaged. The patient had left pupillary miosis in dark but not in bright light. After presenting this case along with the images of the pupillary examination, a group of 21 medical staff were asked several questions on the pupillary examination. Reliability of PLD ratio were assessed via standard error of mean (S.E.M of PLD ratios for 3 different subjects each imaged under constant illumination and fixation but from different angles to the optical axis. Results: Analysis of questionnaire data together with PLD ratios revealed that ~ 14% and 10% of participants could estimate the pupillary size in darkness and bright light respectively but none were simultaneously accurate indicating that subjective assessment of pupillary size was unreliable. The approach towards a systematic pupillary examination was inconsistent among the participants. The PLD ratio was found to be a reliable measure of pupillary size with standard error of mean below 0.1 mm for the three subjects tested. Conclusion: Static pupillary

  11. Isomeric ratio measurements for the radiative neutron capture 176Lu(n,γ at DANCE

    Directory of Open Access Journals (Sweden)

    Denis-Petit D.

    2017-01-01

    Full Text Available The isomeric ratios for the neutron capture reaction 176Lu(n,γ to the Jπ = 5/2−, 761.7 keV, T1/2 = 32.8 ns and the Jπ = 15/2+, 1356.9 keV, T1/2 = 11.1 ns levels of 177Lu, have been measured for the first time with the Detector for Advanced Neutron Capture Experiments (DANCE at the Los Alamos National Laboratory. These measured isomeric ratios are compared with TALYS calculations.

  12. The Discrete Wavelet Transform and Its Application for Noise Removal in Localized Corrosion Measurements

    Directory of Open Access Journals (Sweden)

    Rogelio Ramos

    2017-01-01

    Full Text Available The present work discusses the problem of induced external electrical noise as well as its removal from the electrical potential obtained from Scanning Vibrating Electrode Technique (SVET in the pitting corrosion process of aluminum alloy A96061 in 3.5% NaCl. An accessible and efficient solution of this problem is presented with the use of virtual instrumentation (VI, embedded systems, and the discrete wavelet transform (DWT. The DWT is a computational algorithm for digital processing that allows obtaining electrical noise with Signal to Noise Ratio (SNR superior to those obtained with Lock-In Amplifier equipment. The results show that DWT and the threshold method are efficient and powerful alternatives to carry out electrical measurements of potential signals from localized corrosion processes measured by SVET.

  13. Decay heat removal plan of the SNR-300: a licensed concept

    International Nuclear Information System (INIS)

    Morgenstern, F.H.; Gyr, W.; Stoetzel, H.; Vossebrecker, H.

    1976-01-01

    The report describes how the decay heat removal plan of the SNR-300 has been established in 3 essential licensing steps, thus giving a very significant example for the slow but steady progress in the overall licensing process of the plant. (1) Introduction of an ECCS in addition to the 3 main heat transfer chains as a back-up for rather unlikely and undefined occurrences, 1970; (2) Experimental and computational demonstration of a reliable functioning of the in-vessel natural convection of the fluid flow, 1974; and (3) Proof of fulfilling the general safety and specific reliability criteria for the overall decay heat removal plan; i.e., the 3 main heat transfer chains with specific installations on the steam/water system side and the ECCS, 1976. Some special problem areas, for instance the cavity concept provided for the pipe fracture accident, have still to be licensed, but they do not contribute considerably to the overall risk

  14. Measurement of the form factor ratios in semileptonic decays of charm mesons

    International Nuclear Information System (INIS)

    R. Zaliznyak

    1999-01-01

    I have measured the form factor ratios r 2 = A 2 (0)/A 1 (0) and r V = V (0)/A 1 (0) in the semileptonic charm meson decay D + → (anti K) *0 e + ν e from data collected by the Fermilab E791 collaboration. Form factors are introduced in the calculation of the hadronic current in semileptonic decays of strange, charm, or bottom mesons, such as D + → (anti K) *0 e + ν e . Semileptonic decays provide insight into quark coupling to the W boson since the leptonic and hadronic amplitudes in the Feynman diagram for the decay are completely separate. There are no strong interactions between the final state leptons and quarks. A number of theoretical models predict the values of the form factors for D + → (anti K) *0 e + ν e , though there is a large range of predictions. E791 is a hadroproduction experiment that recorded over 20 billion interactions with a 500 GeV π - beam incident on five thin targets during the 1991-92 Fermilab fixed-target run. Approximately 3000 D + → (anti K) *0 e + ν e decays are fully reconstructed. In order to extract the form factor ratios from the data, I implement a multidimensional unbinned maximum likelihood fit with a large sample of simulated (Monte Carlo) D + → (anti K) *0 e + ν e events. The large E791 data sample provides the most precise measurement of the form factor ratios to date. The measured values for the form factor ratios are r 2 = 0.71 ± 0.08 ± 0.09 and r V = 1.84 ± 0.11 ± 0.08. These results are in good agreement with some Lattice Gauge calculations. However the agreement with quark model predictions is not as good

  15. Optimising neutron polarizers--measuring the flipping ratio and related quantities

    CERN Document Server

    Goossens, D J

    2002-01-01

    The continuing development of gaseous spin polarized sup 3 He transmission filters for use as neutron polarizers makes the choice of optimum thickness for these filters an important consideration. The 'quality factors' derived for the optimisation of transmission filters for particular measurements are general to all neutron polarizers. In this work optimisation conditions for neutron polarizers are derived and discussed for the family of studies related to measuring the flipping ratio from samples. The application of the optimisation conditions to sup 3 He transmission filters and other types of neutron polarizers is discussed. Absolute comparisons are made between the effectiveness of different types of polarizers for this sort of work.

  16. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  17. Neutron spectrometer for DD/DT burning ratio measurement in fusion experimental reactor

    International Nuclear Information System (INIS)

    Asai, Keisuke; Naoi, Norihiro; Iguchi, Tetsuo; Watanabe, Kenichi; Kawarabayashi, Jun; Nishitani, Takeo

    2006-01-01

    The most feasible fuels for a fusion reactor are D (Deuterium) and T (Tritium). DD and/or DT fusion reaction or nuclear burning reaction provides two kinds of neutrons, DD neutron and DT neutron, respectively. DD/DT burning ratio, which can be estimated by DD/DT neutron ratio in the burning plasma, is essential for burn control, alpha particle emission rate monitoring and tritium fuel cycle estimation. Here we propose a new neutron spectrometer for the absolute DD/DT burning ratio measurement. The system consists of a Proton Recoil Telescope (PRT) and a Time-of-Flight (TOF) technique. We have conducted preliminary experiments with a prototype detector and a DT neutron beam (φ20 mm) at the Fusion Neutronics Source, Japan Atomic Energy Agency (JAEA), to assess its basic performance. The detection efficiency obtained by the experiment is consistent with the calculation results in PRT, and sufficient energy resolution for the DD/DT neutron discrimination has been achieved in PRT and TOF. The validity of the Monte Carlo calculation has also been confirmed by comparing the experimental results with the calculation results. The design consideration of this system for use in ITER (International Thermonuclear Experimental Reactor) has shown that this system is capable of monitoring the line-integrated DD/DT burning ratio for the plasma core line of sight with the required measurement accuracy of 20% in the upper 4 decades of the ITER operation (fusion power: 100 kW-700 MW). (author)

  18. Quantitative stress measurement of elastic deformation using mechanoluminescent sensor: An intensity ratio model

    Science.gov (United States)

    Cai, Tao; Guo, Songtao; Li, Yongzeng; Peng, Di; Zhao, Xiaofeng; Liu, Yingzheng

    2018-04-01

    The mechanoluminescent (ML) sensor is a newly developed non-invasive technique for stress/strain measurement. However, its application has been mostly restricted to qualitative measurement due to the lack of a well-defined relationship between ML intensity and stress. To achieve accurate stress measurement, an intensity ratio model was proposed in this study to establish a quantitative relationship between the stress condition and its ML intensity in elastic deformation. To verify the proposed model, experiments were carried out on a ML measurement system using resin samples mixed with the sensor material SrAl2O4:Eu2+, Dy3+. The ML intensity ratio was found to be dependent on the applied stress and strain rate, and the relationship acquired from the experimental results agreed well with the proposed model. The current study provided a physical explanation for the relationship between ML intensity and its stress condition. The proposed model was applicable in various SrAl2O4:Eu2+, Dy3+-based ML measurement in elastic deformation, and could provide a useful reference for quantitative stress measurement using the ML sensor in general.

  19. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    Science.gov (United States)

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  20. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    OpenAIRE

    Mauri, N; Siol, M

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio Rμ = Nμ+/Nμ− in the TeV energy region. We analyzed 403069 cosmic ray muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the Rμ dependence on the primary composition. Rμ is also sho...

  1. High-precision branching-ratio measurement for the superallowed β+ emitter 26Alm

    Science.gov (United States)

    Finlay, P.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Cross, D. S.; Demand, G.; Djongolov, M.; Ettenauer, S.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hackman, G.; Leach, K. G.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Sumithrarachchi, C. S.; Triambak, S.; Williams, S. J.

    2012-05-01

    A high-precision branching-ratio measurement for the superallowed β+ emitter 26Alm was performed at the TRIUMF-ISAC radioactive ion beam facility. An upper limit of ⩽12 ppm at 90% confidence level was found for the second forbidden β+ decay of 26Alm to the 21+ state at 1809 keV in 26Mg. An inclusive upper limit of ⩽15 ppm at 90% confidence level was found when considering all possible nonanalog β+/EC decay branches of 26Alm, resulting in a superallowed branching ratio of 100.0000-0.0015+0%.

  2. Measurement Techniques for Clock Jitter

    Science.gov (United States)

    Lansdowne, Chatwin; Schlesinger, Adam

    2012-01-01

    NASA is in the process of modernizing its communications infrastructure to accompany the development of a Crew Exploration Vehicle (CEV) to replace the shuttle. With this effort comes the opportunity to infuse more advanced coded modulation techniques, including low-density parity-check (LDPC) codes that offer greater coding gains than the current capability. However, in order to take full advantage of these codes, the ground segment receiver synchronization loops must be able to operate at a lower signal-to-noise ratio (SNR) than supported by equipment currently in use.

  3. Measurement of the fission ratio for several configurations of uranium oxide rod clusters

    International Nuclear Information System (INIS)

    Pattenden, S.K.; Patterson, C.R.

    1962-02-01

    This report describes measurements of the fission ratio for a single fuel channel of oxide rod clusters in an essentially infinite block of graphite. The measurements were made using the 'catcher-foil' technique, the activities of the catcher foils being measured by β-counting. Results are given, for 37-rod; 18-rod; 7-rod and 3-rod clusters, and are compared with theoretical predictions. (author)

  4. A study of J-coupling spectroscopy using the Earth's field nuclear magnetic resonance inside a laboratory.

    Science.gov (United States)

    Liao, Shu-Hsien; Chen, Ming-Jye; Yang, Hong-Chang; Lee, Shin-Yi; Chen, Hsin-Hsien; Horng, Herng-Er; Yang, Shieh-Yueh

    2010-10-01

    In this paper, an instrumentation of the Earth's field nuclear magnetic resonance (EFNMR) inside a laboratory is presented. A lock-in analysis (LIA) technique was proposed to enhance the signal-to-noise ratio (SNR). A SNR of 137.8 was achieved in a single measurement for 9 ml tap water, and the LIA technique significantly enhanced the SNR to 188 after a 10-average in a noisy laboratory environment. The proton-phosphorus coupling in trimethyl phosphate ((CH(3)O)(3)PO) with J-coupling J[H,F]=(10.99±0.013) Hz has been demonstrated. The LIA technique improves the SNR, and a 2.6-fold improvement in SNR over that of the frequency-adjusted averaging is achieved. To reduce the noise in EFNMR, it was suggested that the LIA technique and the first order gradient shim be used to achieve a subhertz linewidth.

  5. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    CERN Document Server

    Mauri, N

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio Rμ = Nμ+/Nμ− in the TeV energy region. We analyzed 403069 cosmic ray muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the Rμ dependence on the primary composition. Rμ is also shown as a function of the Òvertical surface energyÓ Eμ cos !. A Þt to a simpliÞed model of muon pro- duction in atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  6. Symbol error rate performance evaluation of the LM37 multimegabit telemetry modulator-demodulator unit

    Science.gov (United States)

    Malek, H.

    1981-01-01

    The LM37 multimegabit telemetry modulator-demodulator unit was tested for evaluation of its symbol error rate (SER) performance. Using an automated test setup, the SER tests were carried out at various symbol rates and signal-to-noise ratios (SNR), ranging from +10 to -10 dB. With the aid of a specially designed error detector and a stabilized signal and noise summation unit, measurement of the SER at low SNR was possible. The results of the tests show that at symbol rates below 20 megasymbols per second (MS)s) and input SNR above -6 dB, the SER performance of the modem is within the specified 0.65 to 1.5 dB of the theoretical error curve. At symbol rates above 20 MS/s, the specification is met at SNR's down to -2 dB. The results of the SER tests are presented with the description of the test setup and the measurement procedure.

  7. Influence of accommodative lag upon the far-gradient measurement of accommodative convergence to accommodation ratio in strabismic patients.

    Science.gov (United States)

    Miyata, Manabu; Hasebe, Satoshi; Ohtsuki, Hiroshi

    2006-01-01

    To determine the influence of the lag of accommodation (LOA) on the accommodative convergence to accommodation (AC/A) ratio measured by the far-gradient method in strabismic patients. The AC/A ratio was measured with a distance target viewed with and without -3.00 diopter (D) addition lenses in 63 patients with different types of strabismus (age range, 7-34 years; range of strabismic angle, -60 to +40 prism diopters; refractive error range, -7.33 to +6.63 D). The LOA for the same lens was measured with an open-view-type autorefractometer. The stimulus AC/A ratio and the AC/A ratio adjusted by the individually measured LOA (adjusted AC/A ratio) were compared. The mean +/- SD of the LOA to the -3.00 D lenses was 1.06 +/- 0.43 D. The mean adjusted AC/A ratio was 41% greater than the stimulus AC/A ratio. The LOA differed widely among patients (0.13 to 2.14 D), and a large LOA tended to appear in myopic or young patients. The AC/A ratio obtained using the conventional far-gradient method is significantly biased by the LOA, and thus does not always represent the actual relationship between accommodation and vergence control systems. Copyright Japanese Ophthalmological Society 2006.

  8. Evaluation of precision in measurements of uranium isotope ratio by thermionic mass spectrometry

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de; Rodrigues, C.

    1977-01-01

    The parameters which affect the precision and accuracy of uranium isotopic ratios measurements by thermionic mass spectrometry are discussed. A statistical designed program for the analysis of the internal and external variances are presented. It was done an application of this statistical methods, in order to get mass discrimination factor, and its standard mean deviation, by using some results already published for 235 U/ 238 U ratio in NBS uranium samples, and natural uranium [pt

  9. High-precision branching ratio measurement for the superallowed β+ emitter Ga62

    Science.gov (United States)

    Finlay, P.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Austin, R. A. E.; Bandyopadhyay, D.; Chaffey, A.; Chakrawarthy, R. S.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Kanungo, R.; Leach, K. G.; Mattoon, C. M.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Savajols, H.; Schumaker, M. A.; Wong, J.

    2008-08-01

    A high-precision branching ratio measurement for the superallowed β+ decay of Ga62 was performed at the Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. The 8π spectrometer, an array of 20 high-purity germanium detectors, was employed to detect the γ rays emitted following Gamow-Teller and nonanalog Fermi β+ decays of Ga62, and the SCEPTAR plastic scintillator array was used to detect the emitted β particles. Thirty γ rays were identified following Ga62 decay, establishing the superallowed branching ratio to be 99.858(8)%. Combined with the world-average half-life and a recent high-precision Q-value measurement for Ga62, this branching ratio yields an ft value of 3074.3±1.1 s, making Ga62 among the most precisely determined superallowed ft values. Comparison between the superallowed ft value determined in this work and the world-average corrected F tmacr value allows the large nuclear-structure-dependent correction for Ga62 decay to be experimentally determined from the CVC hypothesis to better than 7% of its own value, the most precise experimental determination for any superallowed emitter. These results provide a benchmark for the refinement of the theoretical description of isospin-symmetry breaking in A⩾62 superallowed decays.

  10. High-precision half-life and branching-ratio measurements for superallowed Fermi β+ emitters at TRIUMF - ISAC

    Science.gov (United States)

    Laffoley, A. T.; Dunlop, R.; Finlay, P.; Grinyer, G. F.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Blank, B.; Bouzomita, H.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Demand, G.; Diaz Varela, A.; Djongolov, M.; Ettenauer, S.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Glister, J.; Green, K. L.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Tardiff, E. R.; Thomas, J. C.; Towner, I. S.; Triambak, S.; Unsworth, C.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2014-03-01

    A program of high-precision half-life and branching-ratio measurements for superallowed Fermi β emitters is being carried out at TRIUMF's Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. Recent half-life measurements for the superallowed decays of 14O, 18Ne, and 26Alm, as well as branching-ratio measurements for 26Alm and 74Rb are reported. These results provide demanding tests of the Standard Model and the theoretical isospin symmetry breaking (ISB) corrections in superallowed Fermi β decays.

  11. Measurement of β/Λ ratio in IEA-R1 reactor using noise technique

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Kassar, E.

    1986-01-01

    The ratio β/Λ for the IEA-R1 reactor is obtained experimentally through the noise analysis technique. This technique is based on the determination of the power spectral density of the reactor neutron population, with the reactor in a subcritical state driven by a 'white' neutron source. A ratio β/Λ of 43,5 s -1 is estimated from the break frequency of the measured transfer function of the IEA-R1 reactor. (Author) [pt

  12. Measurements of the Proton Elastic-Form-Factor Ratio μpGEp/GMp at Low Momentum Transfer

    International Nuclear Information System (INIS)

    Ron, G.; Piasetzky, E.; Pomerantz, I.; Shneor, R.; Glister, J.; Lee, B.; Choi, Seonho; Kang, H.; Oh, Y.; Song, J.; Yan, X.; Allada, K.; Dutta, C.; Armstrong, W.; Meziani, Z.-E.; Yao, H.; Arrington, J.; Solvignon, P.; Beck, A.; May-Tal Beck, S.

    2007-01-01

    High-precision measurements of the proton elastic form-factor ratio, μ p G E p /G M p , have been made at four-momentum transfer, Q 2 , values between 0.2 and 0.5 GeV 2 . The new data, while consistent with previous results, clearly show a ratio less than unity and significant differences from the central values of several recent phenomenological fits. By combining the new form-factor ratio data with an existing cross-section measurement, one finds that in this Q 2 range the deviation from unity is primarily due to G E p being smaller than expected

  13. Measurement of signal-to-noise ratio performance of TV fluoroscopy systems

    International Nuclear Information System (INIS)

    Geluk, R.J.

    1985-01-01

    A method has been developed for direct measurement of Signal-to-Noise ratio performance on X-ray TV systems. To this end the TV signal resulting from a calibrated test object, is compared with the noise level in the image. The method is objective and produces instantaneous readout, which makes it very suitable for system evaluation under dynamic conditions. (author)

  14. Online stable carbon isotope ratio measurement in formic acid, acetic acid, methanol and ethanol in water by high performance liquid chromatography-isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2008-01-01

    A suitable analysis condition was determined for high performance liquid chromatography-isotope ratio mass spectrometry (HPLC-IRMS) while making sequential measurements of stable carbon isotope ratios of δ 13 C in formic acid, acetic acid, methanol and ethanol dissolved in water. For this online column separation method, organic reagents are not applicable due to carbon contamination; thus, water and KH 2 PO 4 at low concentrations were tested as mobile phase in combination with a HyPURITY AQUASTAR TM column. Formic acid, acetic acid, methanol and ethanol were separated when 2 mM KH 2 PO 4 aqueous solution was used. Under the determined analysis condition for HPLC-IRMS, carbon concentrations could be measured quantitatively as well as carbon isotope ratio when carbon concentration was higher than 0.4 mM L for each chemical

  15. Basic study of water-cement ratio evaluation for fresh mortar using an ultrasonic measurement technique

    International Nuclear Information System (INIS)

    Hamza Haffies Ismail; Murata, Yorinobu

    2009-01-01

    The objective of this research is for the basic study of ultrasonic evaluation method for the determination of the water-cement-ratio (W/C) in fresh concrete at the early age of hardening. Water-cement ratio is a important parameter to evaluate the strength of concrete for concrete construction. Using an ultrasonic pulse measurement technique, wave velocity and frequency variations depend on the age of concrete during hardening process could be evaluated. As a sample test, fresh mortar of water-cement ratio of 40 %, 50% and 60 % was poured into cylindrical plastic mould form (φ100 mm x 50 mm). For an ultrasonic pulse wave transmission technique, two wide band ultrasonic transducers were set on the top and bottom surface of mortar, and start measuring from 10 minutes after pouring water until 60 minutes of 5 minutes of intervals. As a result, it was confirmed that wave velocity and center frequency were changed with the age of mortar depends on the water-cement ratio. (author)

  16. Uncertainties achievable for uranium isotope-amount ratios. Estimates based on the precision and accuracy of recent characterization measurements

    International Nuclear Information System (INIS)

    Mathew, K.J.; Essex, R.M.; Gradle, C.; Narayanan, U.

    2015-01-01

    Certified reference materials (CRMs) recently characterized by the NBL for isotope-amount ratios are: (i) CRM 112-A, Uranium (normal) Metal Assay and Isotopic Standard, (ii) CRM 115, Uranium (depleted) Metal Assay and Isotopic Standard, and (iii) CRM 116-A, Uranium (enriched) Metal Assay and Isotopic Standard. NBL also completed re-characterization of the isotope-amount ratios in CRM 125-A, Uranium (UO 2 ) Pellet Assay, Isotopic, and Radio-chronometric Standard. Three different TIMS analytical techniques were employed for the characterization analyses. The total evaporation technique was used for the major isotope-amount ratio measurement, the modified total evaporation technique was used for both the major and minor isotope-amount ratios, and minor isotope-amount ratios were also measured using a Conventional technique. Uncertainties for the characterization studies were calculated from the combined TIMS data sets following the ISO Guide to the expression of uncertainty in measurement. The uncertainty components for the isotope-amount ratio values are discussed. (author)

  17. On-line component ratio measurement of oil/gas/water mixtures using an admittance sensor

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, J A

    1984-01-01

    The operator of a production platform is primarily interested in which types of fluids a well is producing and how quickly these different components are being produced. The component ratio and production rate of a well vary during the life of a field. To optimize production, measurement of each well's output is thus desirable. Current designs for subsea production systems lack means of continuously measuring three-component flows. A new method of component ratio measurement is described. The fraction of oil, gas and water flowing between two insulated electrode plates is determined by measuring both the electrical conductance and suseptance across the sensor. A preliminary evaluation of the new measurement system has been performed using a process oil/ water/air mixture. The method is not limited to small pipe diameters. The only possible limitation is that for low velocities in very large pipe diameters an in-line mixer may be required. Advantages of this new system are that real-time measurement of void fraction and water content is possible if a non-intrusive rugged sensor is used, and there are no range limitations, as each component may be measured for any given concentration. 4 references.

  18. Comparison of stochastic resonance in static and dynamical nonlinearities

    International Nuclear Information System (INIS)

    Ma, Yumei; Duan, Fabing

    2014-01-01

    We compare the stochastic resonance (SR) effects in parallel arrays of static and dynamical nonlinearities via the measure of output signal-to-noise ratio (SNR). For a received noisy periodic signal, parallel arrays of both static and dynamical nonlinearities can enhance the output SNR by optimizing the internal noise level. The static nonlinearity is easily implementable, while the dynamical nonlinearity has more parameters to be tuned, at the risk of not exploiting the beneficial role of internal noise components. It is of interest to note that, for an input signal buried in the external Laplacian noise, we show that the dynamical nonlinearity is superior to the static nonlinearity in obtaining a better output SNR. This characteristic is assumed to be closely associated with the kurtosis of noise distribution. - Highlights: • Comparison of SR effects in arrays of both static and dynamical nonlinearities. • Static nonlinearity is easily implementable for the SNR enhancement. • Dynamical nonlinearity yields a better output SNR for external Laplacian noise

  19. On the cross-sensitivity between water vapor mixing ratio and stable isotope measurements of in-situ analyzers

    KAUST Repository

    Parkes, Stephen

    2015-04-01

    In recent years there has been an increasing amount of water vapor stable isotope data collected using in-situ instrumentation. A number of papers have characterized the performance of these in-situ analyzers and suggested methods for calibrating raw measurements. The cross-sensitivity of the isotopic measurements on the mixing ratio has been shown to be a major uncertainty and a variety of techniques have been suggested to characterize this inaccuracy. However, most of these are based on relating isotopic ratios to water vapor mixing ratios from in-situ analyzers when the mixing ratio is varied and the isotopic composition kept constant. An additional correction for the span of the isotopic ratio scale is then applied by measuring different isotopic standards. Here we argue that the water vapor cross-sensitivity arises from different instrument responses (span and offset) of the parent H2O isotope and the heavier isotopes, rather than spectral overlap that could cause a true variation in the isotopic ratio with mixing ratio. This is especially relevant for commercial laser optical instruments where absorption lines are well resolved. Thus, the cross-sensitivity determined using more conventional techniques is dependent on the isotopic ratio of the standard used for the characterization, although errors are expected to be small. Consequently, the cross-sensitivity should be determined by characterizing the span and zero offset of each isotope mixing ratio. In fact, this technique makes the span correction for the isotopic ratio redundant. In this work we model the impact of changes in the span and offset of the heavy and light isotopes and illustrate the impact on the cross-sensitivity of the isotopic ratios on water vapor. This clearly shows the importance of determining the zero offset for the two isotopes. The cross-sensitivity of the isotopic ratios on water vapor is then characterized by determining the instrument response for the individual isotopes for a

  20. On the cross-sensitivity between water vapor mixing ratio and stable isotope measurements of in-situ analyzers

    KAUST Repository

    Parkes, Stephen; Wang,  Lixin; McCabe, Matthew

    2015-01-01

    In recent years there has been an increasing amount of water vapor stable isotope data collected using in-situ instrumentation. A number of papers have characterized the performance of these in-situ analyzers and suggested methods for calibrating raw measurements. The cross-sensitivity of the isotopic measurements on the mixing ratio has been shown to be a major uncertainty and a variety of techniques have been suggested to characterize this inaccuracy. However, most of these are based on relating isotopic ratios to water vapor mixing ratios from in-situ analyzers when the mixing ratio is varied and the isotopic composition kept constant. An additional correction for the span of the isotopic ratio scale is then applied by measuring different isotopic standards. Here we argue that the water vapor cross-sensitivity arises from different instrument responses (span and offset) of the parent H2O isotope and the heavier isotopes, rather than spectral overlap that could cause a true variation in the isotopic ratio with mixing ratio. This is especially relevant for commercial laser optical instruments where absorption lines are well resolved. Thus, the cross-sensitivity determined using more conventional techniques is dependent on the isotopic ratio of the standard used for the characterization, although errors are expected to be small. Consequently, the cross-sensitivity should be determined by characterizing the span and zero offset of each isotope mixing ratio. In fact, this technique makes the span correction for the isotopic ratio redundant. In this work we model the impact of changes in the span and offset of the heavy and light isotopes and illustrate the impact on the cross-sensitivity of the isotopic ratios on water vapor. This clearly shows the importance of determining the zero offset for the two isotopes. The cross-sensitivity of the isotopic ratios on water vapor is then characterized by determining the instrument response for the individual isotopes for a

  1. Simultaneous measurement of quantum yield ratio and absorption ratio between acceptor and donor by linearly unmixing excitation-emission spectra.

    Science.gov (United States)

    Zhang, C; Lin, F; DU, M; Qu, W; Mai, Z; Qu, J; Chen, T

    2018-02-13

    Quantum yield ratio (Q A /Q D ) and absorption ratio (K A /K D ) in all excitation wavelengths used between acceptor and donor are indispensable to quantitative fluorescence resonance energy transfer (FRET) measurement based on linearly unmixing excitation-emission spectra (ExEm-spFRET). We here describe an approach to simultaneously measure Q A /Q D and K A /K D values by linearly unmixing the excitation-emission spectra of at least two different donor-acceptor tandem constructs with unknown FRET efficiency. To measure the Q A /Q D and K A /K D values of Venus (V) to Cerulean (C), we used a wide-field fluorescence microscope to image living HepG2 cells separately expressing each of four different C-V tandem constructs at different emission wavelengths with 435 nm and 470 nm excitation respectively to obtain the corresponding excitation-emission spectrum (S DA ). Every S DA was linearly unmixed into the contributions (weights) of three excitation-emission spectra of donor (W D ) and acceptor (W A ) as well as donor-acceptor sensitisation (W S ). Plot of W S /W D versus W A /W D for the four C-V plasmids from at least 40 cells indicated a linear relationship with 1.865 of absolute intercept (Q A /Q D ) and 0.273 of the reciprocal of slope (K A /K D ), which was validated by quantitative FRET measurements adopting 1.865 of Q A /Q D and 0.273 of K A /K D for C32V, C5V, CVC and VCV constructs respectively in living HepG2 cells. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.

  2. Broadband measurements of high-frequency electric field levels and exposure ratios determination

    Directory of Open Access Journals (Sweden)

    Vulević Branislav

    2017-01-01

    Full Text Available The exposure of people to high-frequency electromagnetic fields (over 100 kHz that emanate from modern wireless information transmission systems is inevitable in modern times. Due to the rapid development of new technologies, measuring devices and their connection to measuring systems, the first fifteen years of the 21st century are characterized by the appearance of different approaches to measurements. This prompts the need for the assessment of the exposure of people to these fields. The main purpose of this paper is to show how to determine the exposure ratios based on the results of broadband measurements of the high-frequency electric field in the range of 3 MHz to 18 GHz in the environment.

  3. Combining tracer flux ratio methodology with low-flying aircraft measurements to estimate dairy farm CH4 emissions

    Science.gov (United States)

    Daube, C.; Conley, S.; Faloona, I. C.; Yacovitch, T. I.; Roscioli, J. R.; Morris, M.; Curry, J.; Arndt, C.; Herndon, S. C.

    2017-12-01

    Livestock activity, enteric fermentation of feed and anaerobic digestion of waste, contributes significantly to the methane budget of the United States (EPA, 2016). Studies question the reported magnitude of these methane sources (Miller et. al., 2013), calling for more detailed research of agricultural animals (Hristov, 2014). Tracer flux ratio is an attractive experimental method to bring to this problem because it does not rely on estimates of atmospheric dispersion. Collection of data occurred during one week at two dairy farms in central California (June, 2016). Each farm varied in size, layout, head count, and general operation. The tracer flux ratio method involves releasing ethane on-site with a known flow rate to serve as a tracer gas. Downwind mixed enhancements in ethane (from the tracer) and methane (from the dairy) were measured, and their ratio used to infer the unknown methane emission rate from the farm. An instrumented van drove transects downwind of each farm on public roads while tracer gases were released on-site, employing the tracer flux ratio methodology to assess simultaneous methane and tracer gas plumes. Flying circles around each farm, a small instrumented aircraft made measurements to perform a mass balance evaluation of methane gas. In the course of these two different methane quantification techniques, we were able to validate yet a third method: tracer flux ratio measured via aircraft. Ground-based tracer release rates were applied to the aircraft-observed methane-to-ethane ratios, yielding whole-site methane emission rates. Never before has the tracer flux ratio method been executed with aircraft measurements. Estimates from this new application closely resemble results from the standard ground-based technique to within their respective uncertainties. Incorporating this new dimension to the tracer flux ratio methodology provides additional context for local plume dynamics and validation of both ground and flight-based data.

  4. High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q2

    Energy Technology Data Exchange (ETDEWEB)

    Xiaohui Zhan

    2009-12-01

    A high precision measurement of the proton elastic form factor ratio µpGEp/GMp in the range Q2 = 0.3–0.7 GeV2/c2 was performed using recoil polarimetry in Jefferson Lab Hall A. In this low Q2 range, previous data from LEDEX [5] along with many fits and calculations [2, 3, 4] indicate substantial deviations of the ratio from unity. In this new measurement, with 80% polarized electron beam for 24 days, we are able to achieve <1% statistical uncertainty. Preliminary results are a few percent lower than expected from previous world data and fits, indicating a smaller GEp at this region. Beyond the intrinsic interest in nucleon structure, the improved form factor measurements also have implications for DVCS, determinations of the proton Zemach radius and strangeness form factors through parity violation experiments.

  5. Listening effort and perceived clarity for normal-hearing children with the use of digital noise reduction.

    Science.gov (United States)

    Gustafson, Samantha; McCreery, Ryan; Hoover, Brenda; Kopun, Judy G; Stelmachowicz, Pat

    2014-01-01

    The goal of this study was to evaluate how digital noise reduction (DNR) impacts listening effort and judgment of sound clarity in children with normal hearing. It was hypothesized that when two DNR algorithms differing in signal-to-noise ratio (SNR) output are compared, the algorithm that provides the greatest improvement in overall output SNR will reduce listening effort and receive a better clarity rating from child listeners. A secondary goal was to evaluate the relation between the inversion method measurements and listening effort with DNR processing. Twenty-four children with normal hearing (ages 7 to 12 years) participated in a speech recognition task in which consonant-vowel-consonant nonwords were presented in broadband background noise. Test stimuli were recorded through two hearing aids with DNR off and DNR on at 0 dB and +5 dB input SNR. Stimuli were presented to listeners and verbal response time (VRT) and phoneme recognition scores were measured. The underlying assumption was that an increase in VRT reflects an increase in listening effort. Children rated the sound clarity for each condition. The two commercially available HAs were chosen based on: (1) an inversion technique, which was used to quantify the magnitude of change in SNR with the activation of DNR, and (2) a measure of magnitude-squared coherence, which was used to ensure that DNR in both devices preserved the spectrum. One device provided a greater improvement in overall output SNR than the other. Both DNR algorithms resulted in minimal spectral distortion as measured using coherence. For both devices, VRT decreased for the DNR-on condition, suggesting that listening effort decreased with DNR in both devices. Clarity ratings were also better in the DNR-on condition for both devices. The device showing the greatest improvement in output SNR with DNR engaged improved phoneme recognition scores. The magnitude of this improved phoneme recognition was not accurately predicted with

  6. One-Dimensional-Ratio Measures of Atrophy Progression in Multiple Sclerosis as Evaluated by Longitudinal Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Martola, J.; Wiberg Kristoffersen, M.; Aspelin, P.; Stawiarz, L.; Fredrikson, S.; Hillert, J.; Bergstroem, J.; Flodmark, O.

    2009-01-01

    Background: For decades, normalized one-dimensional (1D) measures have been used in the evaluation of brain atrophy. In multiple sclerosis (MS), the use of normalized linear measures over longitudinal follow-up remains insufficiently documented. Purpose: To evaluate the association between different regional atrophy measures and disability in MS patients over four decades in a longitudinal cross-sectional study. Material and Methods: 37 consecutively selected MS patients were included. At baseline, patients had a range of disease duration (1-33 years) and age (24-65 years). Each patient was followed by magnetic resonance imaging (MRI) for a mean of 9.25 years (range 7.3-10 years). Four 1D measures were applied at three time points on axial 5-mm T1-weighted images. Three clinical MS subgroups were represented: relapsing-remitting MS (RRMS), secondary progressive MS (SPMS), and primary progressive MS (PPMS). Results: There were significant changes in all 1D ratios during follow-up. The Evans ratio (ER) and the bifrontal ratio (BFR) were associated with the development of disability. Changes of ER and BFR reflected more aggressive disease progression, as expressed by MS severity score (MSSS). Conclusion: All four normalized ratios showed uniform atrophy progression, suggesting a consistent rate of atrophy over long-term disease duration independent of MS course. Disability status correlated with 1D measures, suggesting that serial evaluation of Evans and bifrontal ratios might contribute to the radiological evaluation of MS patients

  7. Stable Carbon Isotope Ratio (δ13C Measurement of Graphite Using EA-IRMS System

    Directory of Open Access Journals (Sweden)

    Andrius Garbaras

    2015-06-01

    Full Text Available δ13C values in non-irradiated natural graphite were measured. The measurements were carried out using an elemental analyzer combined with stable isotope ratio mass spectrometer (EA-IRMS. The samples were prepared with ground and non-ground graphite, the part of which was mixed with Mg (ClO42. The best combustion of graphite in the oxidation furnace of the elemental analyzer was achieved when the amount of pulverized graphite ranged from 200 to 490 µg and the mass ratio C:Mg(ClO42 was approximately 1:10. The method for the graphite burning avoiding the isotope fractionation is proposed.DOI: http://dx.doi.org/10.5755/j01.ms.21.2.6873

  8. Study on strontium isotope abundance-ratio measurements by using a 13-MeV proton beam

    Science.gov (United States)

    Jeong, Cheol-Ki; Jang, Han; Lee, Goung-Jin

    2016-09-01

    The Rb-Sr dating method is used in dating Paleozoic and Precambrian rocks. This method measures the 87Rb and the 87Sr concentrations by using thermal ionization mass spectrometry (TIMS) [J. Hefne et al., Inter. J. Phys. Sci. 3(1), 28 (2008)]. In addition, it calculates the initial 87Sr/86Sr ratio to increase the reliability of Rb-Sr dating. In this study, the 87Sr/86Sr ratio was measured by using a 13-MeV proton accelerator. Proton kinetic energies are in the range of tens of megaelectronvolts, and protons have large absorption cross-sections for ( p, n) reactions with most substances. After absorbing a proton with such a high kinetic energy, an element is converted into a nuclide with its atomic number increased by one via nuclear transmutation. These nuclides usually have short half-lives and return to the original state through radioactive decay. When a strontium sample is irradiated with protons, nuclear transmutation occurs; thus, the strontium isotope present in the sample changes to a yttrium isotope, which is an activated radioisotope. Based on this, the 87Sr/86Sr ratio was calculated by analyzing the gamma-rays emitted by each yttrium isotope. The KIRAMS-13 cyclotron at the Cyclotron Center of Chosun University, where 13-MeV protons can be extracted, was utilized in our experiment. The 87Sr/86Sr isotope ratio was computed for samples irradiated with these protons, and the result was similar to the isotope ratio for the Standard Reference Material, i.e., 98.2 ± 3.4%. As part of the analysis, proton activation analyses were performed using 13-MeV protons, and the experimental results of this research suggest a possible approach for measuring the strontium-isotope abundance ratio of samples.

  9. A measurement of the branching ratio for the Σ+ → pγ decay

    International Nuclear Information System (INIS)

    Hessey, N.P.; Lowe, J.; Booth, E.C.; Gall, K.P.; McIntyre, E.K.; Miller, J.P.; Roberts, B.L.; Whitehouse, D.A.; Fickinger, W.J.; Robinson, D.K.; Hasinoff, M.D.; Measday, D.F.; Noble, A.J.; Horvath, D.; Salomon, M.

    1989-01-01

    We have measured the weak radiative decay branching ratio (Σ + → pγ)/(Σ + → pπ 0 ). The experiment was carried out at Brookhaven National Laboratory using a low-energy separated K - beam stopping in liquid hydrogen. The Σ + was tagged by observing the pion from K - p → Σ + π - in a range telescope, and the gamma was detected in a segmented NaI detector. The result is (2.81 ± 0.39 +0.21 0.43 ) x 10 -3 , which is consistent with previous measurements. This corresponds to a branching ratio for (Σ + → pγ)/(Σ + → all) of (1.45 ± 0.20 +0.11 0.22 ) x 10 -3 , where the quoted errors are statistical and systematic, respectively. A total of 408 signal events were observed, doubling the previous world total. (orig.)

  10. Accurate branching ratio measurements in 23Na(p,γ)24Mg

    International Nuclear Information System (INIS)

    Boydell, S.G.; Sargood, D.G.

    1975-01-01

    The reaction 23 Na(p,γ) 24 Mg has been investigated in the proton energy range 0.3-1.75 MeV. Gamma ray spectra were measured for 22 resonances with Ge(Li) detectors which were carefully calibrated for relative peak efficiencies. Allowance was made for the effect of anisotropies in all the emitted γ-rays. The spectra have been analysed to give branching ratios for bound and unbound levels. (author)

  11. Measurement of the antineutrino to neutrino charged-current interaction cross section ratio in MINERvA

    Science.gov (United States)

    Ren, L.; Aliaga, L.; Altinok, O.; Bellantoni, L.; Bercellie, A.; Betancourt, M.; Bodek, A.; Bravar, A.; Budd, H.; Cai, T.; Carneiro, M. F.; da Motta, H.; Devan, J.; Dytman, S. A.; Díaz, G. A.; Eberly, B.; Endress, E.; Felix, J.; Fields, L.; Fine, R.; Gago, A. M.; Galindo, R.; Gallagher, H.; Ghosh, A.; Golan, T.; Gran, R.; Han, J. Y.; Harris, D. A.; Hurtado, K.; Kiveni, M.; Kleykamp, J.; Kordosky, M.; Le, T.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; Martinez Caicedo, D. A.; McFarland, K. S.; McGivern, C. L.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Norrick, A.; Nuruzzaman, Paolone, V.; Park, J.; Patrick, C. E.; Perdue, G. N.; Ramírez, M. A.; Ransome, R. D.; Ray, H.; Rimal, D.; Rodrigues, P. A.; Ruterbories, D.; Schellman, H.; Solano Salinas, C. J.; Sultana, M.; Sánchez Falero, S.; Valencia, E.; Walton, T.; Wolcott, J.; Wospakrik, M.; Yaeggy, B.; MinerνA Collaboration

    2017-04-01

    We present measurements of the neutrino and antineutrino total charged-current cross sections on carbon and their ratio using the MINERvA scintillator-tracker. The measurements span the energy range 2-22 GeV and were performed using forward and reversed horn focusing modes of the Fermilab low-energy NuMI beam to obtain large neutrino and antineutrino samples. The flux is obtained using a subsample of charged-current events at low hadronic energy transfer along with precise higher energy external neutrino cross section data overlapping with our energy range between 12-22 GeV. We also report on the antineutrino-neutrino cross section ratio, RCC , which does not rely on external normalization information. Our ratio measurement, obtained within the same experiment using the same technique, benefits from the cancellation of common sample systematic uncertainties and reaches a precision of ˜5 % at low energy. Our results for the antineutrino-nucleus scattering cross section and for RCC are the most precise to date in the energy range Eν<6 GeV .

  12. Low-Noise Active Decoupling Circuit and its Application to 13C Cryogenic RF Coils at 3T

    DEFF Research Database (Denmark)

    Sanchez, Juan Diego; Søvsø Szocska Hansen, Esben; Laustsen, Christoffer

    2017-01-01

    We analyze the loss contributions in a small, 50-mm-diameter receive-only coil for carbon-13 (13C) magnetic resonance imaging at 3 T for 3 different circuits, which, including active decoupling, are compared in terms of their Q-factors and signal-to-noise ratio (SNR). The results show that a circ......We analyze the loss contributions in a small, 50-mm-diameter receive-only coil for carbon-13 (13C) magnetic resonance imaging at 3 T for 3 different circuits, which, including active decoupling, are compared in terms of their Q-factors and signal-to-noise ratio (SNR). The results show...... that a circuit using unsegmented tuning and split matching capacitors can provide 20% SNR enhancement at room temperature compared with that using more traditional designs. The performance of the proposed circuit was also measured when cryogenically cooled to 105 K, and an additional 1.6-fold SNR enhancement...... was achieved on a phantom. The enhanced circuit performance is based on the low capacitance needed to match to 50 when coil losses are low, which significantly reduces the proportion of the current flowing through the matching network and therefore minimizes this loss contribution. This effect makes...

  13. Measurement of L3 subshell absorption jump ratios and jump factors for high Z elements using EDXRF technique

    International Nuclear Information System (INIS)

    Kaçal, M.R.

    2014-01-01

    Energy dispersive X-ray fluorescence technique (EDXRF) has been employed for measuring L 3 -subshell absorption jump ratios, r L 3 and jump factors, J L 3 for high Z elements. Jump factors and jump ratios for these elements have been determined by measuring L 3 subshell fluorescence parameters such as L 3 subshell X-ray production cross section σ L 3 , L 3 subshell fluorescence yield, ω L 3 , total L 3 subshell and higher subshells photoionization cross section σ L T . Measurements were performed using a Cd-109 radioactive point source and an Si(Li) detector in direct excitation experimental geometry. Measured values for jump factors and jump ratios have been compared with theoretically calculated and other experimental values. - Highlights: • This paper regards L 3 subshell absorption jump ratios and jump factors using the EDXRF method. • These parameters were measured using a new method. • This method is more useful than other methods which require much effort. • Results are in good agreement with theoretical and experimental values

  14. Measurement of the form factor ratios in semileptonic decays of charm mesons

    Energy Technology Data Exchange (ETDEWEB)

    Zaliznyak, Renata [Stanford Univ., CA (United States)

    1998-05-01

    I have measured the form factor ratios r2 = A2 (0)/A1 (0) and rV = V (0)/A1 (0) in the semileptonic charm meson decay D+ → $\\bar{K}$*0 e+ve from data collected by the Fermilab E791 collaboration. Form factors are introduced in the calculation of the hadronic current in semileptonic decays of strange, charm, or bottom mesons, such as D+ → $\\bar{K}$*0 e+ ve . Semileptonic decays provide insight into quark coupling to the W boson since the leptonic and hadronic amplitudes in the Feynman diagram for the decay are completely separate. There are no strong interactions between the final state leptons and quarks. A number of theoretical models predict the values of the form factors for D+ → $\\bar{K}$*0 e+ ve , though there is a large range of predictions. E791 is a hadroproduction experiment that recorded over 20 billion interactions with a 500 GeV π- beam incident on five thin targets during the 1991-92 Fermilab fixed-target run. Approximately 3000 D+ → $\\bar{K}$*0 e+ ve decays are fully reconstructed. In order to extract the form factor ratios from the data, I implement a multidimensional unbinned maximum likelihood fit with a large sample of simulated (Monte Carlo) D+ → $\\bar{K}$*0 e+ve events. The large E791 data sample provides the most precise measurement of the form factor ratios to date. The measured values for the form factor ratios are r2 = 0.71 ± 0.08 ± 0.09 and rV = 1.84 ± 0.11 ±} 0.08. These results are in good agreement with some Lattice Gauge calculations. However the agreement with quark model predictions is not as good.

  15. Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope

    International Nuclear Information System (INIS)

    Pandya, Shwetang N.; Sano, Ryuichi; Peterson, Byron J.; Mukai, Kiyofumi; Enokuchi, Akito; Takeyama, Norihide

    2014-01-01

    An Infrared imaging Video Bolometer (IRVB) diagnostic is currently being used in the Large Helical Device (LHD) for studying the localization of radiation structures near the magnetic island and helical divertor X-points during plasma detachment and for 3D tomography. This research demands high signal to noise ratio (SNR) and sensitivity to improve the temporal resolution for studying the evolution of radiation structures during plasma detachment and a wide IRVB field of view (FoV) for tomography. Introduction of an infrared periscope allows achievement of a higher SNR and higher sensitivity, which in turn, permits a twofold improvement in the temporal resolution of the diagnostic. Higher SNR along with wide FoV is achieved simultaneously by reducing the separation of the IRVB detector (metal foil) from the bolometer's aperture and the LHD plasma. Altering the distances to meet the aforesaid requirements results in an increased separation between the foil and the IR camera. This leads to a degradation of the diagnostic performance in terms of its sensitivity by 1.5-fold. Using an infrared periscope to image the IRVB foil results in a 7.5-fold increase in the number of IR camera pixels imaging the foil. This improves the IRVB sensitivity which depends on the square root of the number of IR camera pixels being averaged per bolometer channel. Despite the slower f-number (f/# = 1.35) and reduced transmission (τ 0 = 89%, due to an increased number of lens elements) for the periscope, the diagnostic with an infrared periscope operational on LHD has improved in terms of sensitivity and SNR by a factor of 1.4 and 4.5, respectively, as compared to the original diagnostic without a periscope (i.e., IRVB foil being directly imaged by the IR camera through conventional optics). The bolometer's field of view has also increased by two times. The paper discusses these improvements in apt details

  16. Measures of effect size for chi-squared and likelihood-ratio goodness-of-fit tests.

    Science.gov (United States)

    Johnston, Janis E; Berry, Kenneth J; Mielke, Paul W

    2006-10-01

    A fundamental shift in editorial policy for psychological journals was initiated when the fourth edition of the Publication Manual of the American Psychological Association (1994) placed emphasis on reporting measures of effect size. This paper presents measures of effect size for the chi-squared and the likelihood-ratio goodness-of-fit statistic tests.

  17. An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz

    International Nuclear Information System (INIS)

    Kim, Dan Bee; Lee, Hyung Kew; Kim, Wan-Seop

    2017-01-01

    This paper describes a 2-terminal-pair impedance bridge, measuring the capacitance ratio in the high frequency range up to 1 MHz. The bridge was configured with two voltage sources and a phase control unit which enabled the bridge balance by synchronizing the voltage sources with an enhanced phase resolution. Without employing the transformers such as inductive voltage divider, injection and detection transformers, etc, the bridge system is quite simple to set up, and the balance procedure is quick and easy. Using this dual-source coaxial bridge, the 1:1 and 10:1 capacitance ratios were measured with 1 pF–1 nF capacitors in the frequency range from 1 kHz to 1 MHz. The measurement values obtained by the dual-source bridge were then compared with reference values measured using a commercial precision capacitance bridge of AH2700A, the Z -matrix method developed by ourselves, and the 4-terminal-pair coaxial bridge by the Czech Metrological Institute. All the measurements agreed within the reference uncertainty range of an order of 10 −6 –10 −5 , proving the bridge ability as a trustworthy tool for measuring the capacitance ratio in the high frequency range. (paper)

  18. Measurement of $V^0$ production ratios in $pp$ collisions at $\\sqrt{s}$ = 0.9 and 7 TeV

    CERN Document Server

    Aaij, R.; Adinolfi, M.; Adrover, C.; Affolder, A.; Ajaltouni, Z.; Albrecht, J.; Alessio, F.; Alexander, M.; Alkhazov, G.; Alvarez Cartelle, P.; Alves Jr, A.A.; Amato, S.; Amhis, Y.; Anderson, J.; Appleby, R.B.; Aquines Gutierrez, O.; Arrabito, L.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Bachmann, S.; Back, J.J.; Bailey, D.S.; Balagura, V.; Baldini, W.; Barlow, R.J.; Barschel, C.; Barsuk, S.; Barter, W.; Bates, A.; Bauer, C.; Bauer, Th.; Bay, A.; Bediaga, I.; Belous, K.; Belyaev, I.; Ben-Haim, E.; Benayoun, M.; Bencivenni, G.; Benson, S.; Bernet, R.; Bettler, M.O.; van Beuzekom, M.; Bien, A.; Bifani, S.; Bizzeti, A.; Bjornstad, P.M.; Blake, T.; Blanc, F.; Blanks, C.; Blouw, J.; Blusk, S.; Bobrov, A.; Bocci, V.; Bondar, A.; Bondar, N.; Bonivento, W.; Borghi, S.; Borgia, A.; Bowcock, T.J.V.; Bozzi, C.; Brambach, T.; van den Brand, J.; Bressieux, J.; Brett, D.; Brisbane, S.; Britsch, M.; Britton, T.; Brook, N.H.; Buchler-Germann, A.; Burducea, I.; Bursche, A.; Buytaert, J.; Cadeddu, S.; Caicedo Carvajal, J.M.; Callot, O.; Calvi, M.; Calvo Gomez, M.; Camboni, A.; Campana, P.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Cattaneo, M.; Charles, M.; Charpentier, Ph.; Chiapolini, N.; Cid Vidal, X.; Ciezarek, G.; Clarke, P.E.L.; Clemencic, M.; Cliff, H.V.; Closier, J.; Coca, C.; Coco, V.; Cogan, J.; Collins, P.; Constantin, F.; Conti, G.; Contu, A.; Coombes, M.; Corti, G.; Cowan, G.A.; Currie, R.; D'Almagne, B.; D'Ambrosio, C.; David, P.; De Bonis, I.; De Capua, S.; De Cian, M.; De Lorenzi, F.; De Miranda, J.M.; De Paula, L.; De Simone, P.; Decamp, D.; Deckenhoff, M.; Degaudenzi, H.; Deissenroth, M.; Del Buono, L.; Deplano, C.; Deschamps, O.; Dettori, F.; Dickens, J.; Dijkstra, H.; Diniz Batista, P.; Dossett, D.; Dovbnya, A.; Dupertuis, F.; Dzhelyadin, R.; Eames, C.; Easo, S.; Egede, U.; Egorychev, V.; Eidelman, S.; van Eijk, D.; Eisele, F.; Eisenhardt, S.; Ekelhof, R.; Eklund, L.; Elsasser, Ch.; d'Enterria, D.G.; Esperante Pereira, D.; Esteve, L.; Falabella, A.; Fanchini, E.; Farber, C.; Fardell, G.; Farinelli, C.; Farry, S.; Fave, V.; Fernandez Albor, V.; Ferro-Luzzi, M.; Filippov, S.; Fitzpatrick, C.; Fontana, M.; Fontanelli, F.; Forty, R.; Frank, M.; Frei, C.; Frosini, M.; Furcas, S.; Gallas Torreira, A.; Galli, D.; Gandelman, M.; Gandini, P.; Gao, Y.; Garnier, J-C.; Garofoli, J.; Garra Tico, J.; Garrido, L.; Gaspar, C.; Gauvin, N.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Gibson, V.; Gligorov, V.V.; Gobel, C.; Golubkov, D.; Golutvin, A.; Gomes, A.; Gordon, H.; Grabalosa Gandara, M.; Graciani Diaz, R.; Granado Cardoso, L.A.; Grauges, E.; Graziani, G.; Grecu, A.; Gregson, S.; Gui, B.; Gushchin, E.; Guz, Yu.; Gys, T.; Haefeli, G.; Haen, C.; Haines, S.C.; Hampson, T.; Hansmann-Menzemer, S.; Harji, R.; Harnew, N.; Harrison, J.; Harrison, P.F.; He, J.; Heijne, V.; Hennessy, K.; Henrard, P.; Hernando Morata, J.A.; van Herwijnen, E.; Hofmann, W.; Holubyev, K.; Hopchev, P.; Hulsbergen, W.; Hunt, P.; Huse, T.; Huston, R.S.; Hutchcroft, D.; Hynds, D.; Iakovenko, V.; Ilten, P.; Imong, J.; Jacobsson, R.; Jaeger, A.; Jahjah Hussein, M.; Jans, E.; Jansen, F.; Jaton, P.; Jean-Marie, B.; Jing, F.; John, M.; Johnson, D.; Jones, C.R.; Jost, B.; Kandybei, S.; Karacson, M.; Karbach, T.M.; Keaveney, J.; Kerzel, U.; Ketel, T.; Keune, A.; Khanji, B.; Kim, Y.M.; Knecht, M.; Koblitz, S.; Koppenburg, P.; Kozlinskiy, A.; Kravchuk, L.; Kreplin, K.; Kreps, M.; Krocker, G.; Krokovny, P.; Kruse, F.; Kruzelecki, K.; Kucharczyk, M.; Kukulak, S.; Kumar, R.; Kvaratskheliya, T.; La Thi, V.N.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lambert, D.; Lambert, R.W.; Lanciotti, E.; Lanfranchi, G.; Langenbruch, C.; Latham, T.; Le Gac, R.; van Leerdam, J.; Lees, J.P.; Lefevre, R.; Leflat, A.; Lefrancois, J.; Leroy, O.; Lesiak, T.; Li, L.; Li, Y.Y.; Li Gioi, L.; Lieng, M.; Lindner, R.; Linn, C.; Liu, B.; Liu, G.; Lopes, J.H.; Lopez Asamar, E.; Lopez-March, N.; Luisier, J.; Machefert, F.; Machikhiliyan, I.V.; Maciuc, F.; Maev, O.; Magnin, J.; Malde, S.; Mamunur, R.M.D.; Manca, G.; Mancinelli, G.; Mangiafave, N.; Marconi, U.; Marki, R.; Marks, J.; Martellotti, G.; Martens, A.; Martin, L.; Martin Sanchez, A.; Martinez Santos, D.; Massafferri, A.; Mathe, Z.; Matteuzzi, C.; Matveev, M.; Maurice, E.; Maynard, B.; Mazurov, A.; McGregor, G.; McNulty, R.; Mclean, C.; Meissner, M.; Merk, M.; Merkel, J.; Messi, R.; Miglioranzi, S.; Milanes, D.A.; Minard, M.N.; Monteil, S.; Moran, D.; Morawski, P.; Morris, J.V.; Mountain, R.; Mous, I.; Muheim, F.; Muller, K.; Muresan, R.; Muryn, B.; Musy, M.; Naik, P.; Nakada, T.; Nandakumar, R.; Nardulli, J.; Nasteva, I.; Nedos, M.; Needham, M.; Neufeld, N.; Nguyen-Mau, C.; Nicol, M.; Nies, S.; Niess, V.; Nikitin, N.; Oblakowska-Mucha, A.; Obraztsov, V.; Oggero, S.; Ogilvy, S.; Okhrimenko, O.; Oldeman, R.; Orlandea, M.; Otalora Goicochea, J.M.; Owen, P.; Pal, B.; Palacios, J.; Palutan, M.; Panman, J.; Papanestis, A.; Pappagallo, M.; Parkes, C.; Parkinson, C.J.; Passaleva, G.; Patel, G.D.; Patel, M.; Paterson, S.K.; Patrick, G.N.; Patrignani, C.; Pavel-Nicorescu, C.; Pazos Alvarez, A.; Pellegrino, A.; Penso, G.; Pepe Altarelli, M.; Perazzini, S.; Perego, D.L.; Perez Trigo, E.; Perez-Calero Yzquierdo, A.; Perret, P.; Perrin-Terrin, M.; Pessina, G.; Petrella, A.; Petrolini, A.; Pie Valls, B.; Pietrzyk, B.; Pilar, T.; Pinci, D.; Plackett, R.; Playfer, S.; Plo Casasus, M.; Polok, G.; Poluektov, A.; Polycarpo, E.; Popov, D.; Popovici, B.; Potterat, C.; Powell, A.; Pree, T.du; Prisciandaro, J.; Pugatch, V.; Puig Navarro, A.; Qian, W.; Rademacker, J.H.; Rakotomiaramanana, B.; Raniuk, I.; Raven, G.; Redford, S.; Reid, M.M.; Reis, A.C.dos; Ricciardi, S.; Rinnert, K.; Roa Romero, D.A.; Robbe, P.; Rodrigues, E.; Rodrigues, F.; Rodriguez Perez, P.; Rogers, G.J.; Romanovsky, V.; Rouvinet, J.; Ruf, T.; Ruiz, H.; Sabatino, G.; Saborido Silva, J.J.; Sagidova, N.; Sail, P.; Saitta, B.; Salzmann, C.; Sannino, M.; Santacesaria, R.; Santinelli, R.; Santovetti, E.; Sapunov, M.; Sarti, A.; Satriano, C.; Satta, A.; Savrie, M.; Savrina, D.; Schaack, P.; Schiller, M.; Schleich, S.; Schmelling, M.; Schmidt, B.; Schneider, O.; Schopper, A.; Schune, M.H.; Schwemmer, R.; Sciubba, A.; Seco, M.; Semennikov, A.; Senderowska, K.; Sepp, I.; Serra, N.; Serrano, J.; Seyfert, P.; Shao, B.; Shapkin, M.; Shapoval, I.; Shatalov, P.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, O.; Shevchenko, V.; Shires, A.; Silva Coutinho, R.; Skottowe, H.P.; Skwarnicki, T.; Smith, A.C.; Smith, N.A.; Sobczak, K.; Soler, F.J.P.; Solomin, A.; Soomro, F.; Souza De Paula, B.; Spaan, B.; Sparkes, A.; Spradlin, P.; Stagni, F.; Stahl, S.; Steinkamp, O.; Stoica, S.; Stone, S.; Storaci, B.; Straticiuc, M.; Straumann, U.; Styles, N.; Swientek, S.; Szczekowski, M.; Szczypka, P.; Szumlak, T.; T'Jampens, S.; Teodorescu, E.; Teubert, F.; Thomas, C.; Thomas, E.; van Tilburg, J.; Tisserand, V.; Tobin, M.; Topp-Joergensen, S.; Tran, M.T.; Tsaregorodtsev, A.; Tuning, N.; Ukleja, A.; Urquijo, P.; Uwer, U.; Vagnoni, V.; Valenti, G.; Vazquez Gomez, R.; Vazquez Regueiro, P.; Vecchi, S.; Velthuis, J.J.; Veltri, M.; Vervink, K.; Viaud, B.; Videau, I.; Vilasis-Cardona, X.; Visniakov, J.; Vollhardt, A.; Voong, D.; Vorobyev, A.; Voss, H.; Wacker, K.; Wandernoth, S.; Wang, J.; Ward, D.R.; Webber, A.D.; Websdale, D.; Whitehead, M.; Wiedner, D.; Wiggers, L.; Wilkinson, G.; Williams, M.P.; Williams, M.; Wilson, F.F.; Wishahi, J.; Witek, M.; Witzeling, W.; Wotton, S.A.; Wyllie, K.; Xie, Y.; Xing, F.; Yang, Z.; Young, R.; Yushchenko, O.; Zavertyaev, M.; Zhang, L.; Zhang, W.C.; Zhang, Y.; Zhelezov, A.; Zhong, L.; Zverev, E.

    2011-01-01

    The $\\bar{\\Lambda} / \\Lambda$ and $\\bar{\\Lambda} / K^0_\\mathrm{S}$ production ratios are measured by the LHCb detector from $0.3\\,\\mathrm{nb}^{-1}$ of $pp$ collisions delivered by the LHC at $\\sqrt{s} = 0.9$\\,TeV and $1.8\\,\\mathrm{nb}^{-1}$ at $\\sqrt{s} = 7$\\,TeV. Both ratios are presented as a function of transverse momentum, $p_\\mathrm{T}$, and rapidity, $y$, in the ranges {$0.15 < p_\\mathrm{T} < 2.50\\,\\mathrm{GeV}/c$} and {$2.0measurements. The ratio $\\bar{\\Lambda} / \\Lambda$, measuring the transport of baryon number from the collision into the detector, is smaller in data than predicted in simulation, particularly at high rapidity. The ratio $\\bar{\\Lambda} / K^0_\\mathrm{S}$, measuring the baryon-to-meson suppression in strange quark hadronisation, is significantly larger than expected.

  19. Measurement of the ratio h / e with a photomultiplier tube and a set of LEDs

    International Nuclear Information System (INIS)

    Loparco, F; Malagoli, M S; Rainò, S; Spinelli, P

    2017-01-01

    We propose a laboratory experience aimed at undergraduate physics students to understand the main features of the photoelectric effect and to perform a measurement of the ratio h / e , where h is Planck’s constant and e is the electron charge. The experience is based on the method developed by Millikan for his measurements of the photoelectric effect in the years from 1912 to 1915. The experimental setup consists of a photomultiplier tube (PMT) equipped with a voltage divider properly modified to set variable retarding potentials between the photocathode and the first dynode, and a set of LEDs emitting at different wavelengths. The photocathode is illuminated with the various LEDs and, for each wavelength of the incident light, the output anode current is measured as a function of the retarding potential applied between the cathode and the first dynode. From each measurement, a value of the stopping potential for the anode current is derived. Finally, the stopping potentials are plotted as a function of the frequency of the incident light, and a linear fit is performed. The slope and the intercept of the line allow one to respectively evaluate the ratio h / e and the ratio W / e , where W is the work function of the photocathode. (paper)

  20. Correction of mass spectrometric isotope ratio measurements for isobaric isotopologues of O2, CO, CO2, N2O and SO2.

    Science.gov (United States)

    Kaiser, Jan; Röckmann, Thomas

    2008-12-01

    Gas isotope ratio mass spectrometers usually measure ion current ratios of molecules, not atoms. Often several isotopologues contribute to an ion current at a particular mass-to-charge ratio (m/z). Therefore, corrections have to be applied to derive the desired isotope ratios. These corrections are usually formulated in terms of isotope ratios (R), but this does not reflect the practice of measuring the ion current ratios of the sample relative to those of a reference material. Correspondingly, the relative ion current ratio differences (expressed as delta values) are first converted into isotopologue ratios, then into isotope ratios and finally back into elemental delta values. Here, we present a reformulation of this data reduction procedure entirely in terms of delta values and the 'absolute' isotope ratios of the reference material. This also shows that not the absolute isotope ratios of the reference material themselves, but only product and ratio combinations of them, are required for the data reduction. These combinations can be and, for carbon and oxygen have been, measured by conventional isotope ratio mass spectrometers. The frequently implied use of absolute isotope ratios measured by specially calibrated instruments is actually unnecessary. Following related work on CO2, we here derive data reduction equations for the species O2, CO, N2O and SO2. We also suggest experiments to measure the required absolute ratio combinations for N2O, SO2 and O2. As a prelude, we summarise historic and recent measurements of absolute isotope ratios in international isotope reference materials. Copyright 2008 John Wiley & Sons, Ltd.

  1. Study of the matrix specific mass discrimination effects during inductively coupled plasma mass spectrometry isotope ratio measurements

    International Nuclear Information System (INIS)

    Vassileva, E.; Quetel, Ch.R.

    2004-01-01

    Sample matrix related effects on mass discrimination during inductively coupled plasma mass spectrometry (ICP-MS) isotope ratio measurements have only been rarely reported. However, they can lead to errors larger than the uncertainty claimed on the ratio results when not properly taken into account or corrected for. These matrix specific affects were experienced during an Isotope Dilution Mass Spectrometry (IDMS) campaign we carried out for the certification of the Cd amount content in some food digest samples (7% acidity and salts content around 450μg g -1 ). Dilution was not possible for Cd only present at the low ng g -1 level. Up to 1% difference was observed on Cd isotope ratio results between measurements performed directly or after matrix separation. This was a significant difference considering that less than 1.5% relative combined uncertainty was eventually estimated for these IDMS measurements. Similar results could be obtained either way after the implementation of necessary corrections. The direct measurement approach associated to a correction for mass discrimination effects using the food digest sample itself (and the IUPAC table values as reference for the natural Cd isotopic composition) was preferred as it was the easiest. Consequently, the impact of matrix effects on mass discrimination during isotope ratio measurements with two types of ICP- MS (quadrupole and magnetic sector instruments) was studied for 4 elements (Li, Cu, Cd and Tl). Samples of varying salinity (up to 0.25%) and acidity (up to 7%) characteristics were prepared using isotopic certified reference materials of these elements. The long term and short-term stability, respectively reproducibility and repeatability, of the results, as well as the evolution of the difference to certified ratio values were monitored. As expected the 13 investigated isotopic ratios were all sensitive to variations in salt and acid concentrations. Our experiments also showed that simultaneous variation

  2. Myocardial first pass perfusion imaging with gadobutrol: impact of parallel imaging algorithms on image quality and signal behavior.

    Science.gov (United States)

    Theisen, Daniel; Wintersperger, Bernd J; Huber, Armin; Dietrich, Olaf; Reiser, Maximilian F; Schönberg, Stefan O

    2007-07-01

    To implement parallel imaging algorithms in fast gradient recalled echo sequences for myocardial perfusion imaging and evaluate image quality, signal-to-noise ratio (SNR), contrast-enhancement ratio (CER), and semiquantitative perfusion parameters. In 20 volunteers, myocardial perfusion imaging with gadobutrol was performed at rest using an accelerated TurboFLASH sequence (TR 2.3 milliseconds, TE 0.93 milliseconds, flip angle [FA] 15 degrees) with GRAPPA, R=2. A nonaccelerated TurboFLASH sequence with similar scan parameters served as standard of reference. Artifacts were assessed qualitatively. SNR, CER, and CNR were calculated and semiquantitative perfusion parameters were determined from fitted SI-time curves. Phantom measurements yielded significant higher SNR for nonaccelerated images (Pimages (Pimages for artifacts by 2 board-certified radiologists yielded a significant reduction in dark rim artifacts with GRAPPA, R=2 (P<0.001). The application of GRAPPA with an acceleration factor of R=2 leads to a significant reduction of dark rim artifacts in fast gradient recalled echo sequences.

  3. Fabrication of fuel elements interplay between typical SNR Mark Ia specifications and the fuel element fabrication

    International Nuclear Information System (INIS)

    Biermann, W.K.; Heuvel, H.J.; Pilate, S.; Vanderborck, Y.; Pelckmans, E.; Vanhellemont, G.; Roepenack, H.; Stoll, W.

    1987-01-01

    The core and fuel were designed for the SNR-300 first core by Interatom GmbH and Belgonucleaire. The fuel was fabricated by Alkem/RBU and Belgonucleaire. Based on the preparation of drawings and specifications and on the results of the prerun fabrication, an extensive interplay took place between design requirements, specifications, and fabrication processes at both fuel plants. During start-up of pellet and pin fabrication, this solved such technical questions as /sup 239/Pu equivalent linear weight, pellet density, stoichiometry of the pellets, and impurity content. Close cooperation of designers and manufacturers has allowed manufacture of 205 fuel assemblies without major problems

  4. Detailed investigation of the gamma-ray emission in the vicinity of SNR W28 with Fermi-LAT

    Energy Technology Data Exchange (ETDEWEB)

    Hanabata, Y. [Institute for Cosmic-Ray Research, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8582 (Japan); Katagiri, H. [College of Science, Ibaraki University, 2-1-1, Bunkyo, Mito 310-8512 (Japan); Hewitt, J.W. [CRESST, University of Maryland, Baltimore County, Baltimore, MD 21250 (United States); Ballet, J. [Laboratoire AIM, CEA-IRFU/CNRS/Université Paris Diderot, Service d' Astrophysique, CEA Saclay, F-91191 Gif sur Yvette (France); Fukazawa, Y. [Department of Physical Sciences, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Fukui, Y.; Hayakawa, T. [Department of Physics and Astrophysics, Nagoya University, Chikusa-ku Nagoya 464-8602 (Japan); Lemoine-Goumard, M. [Centre d' Études Nucléaires de Bordeaux Gradignan, IN2P3/CNRS, Université Bordeaux 1, BP120, F-33175 Gradignan Cedex (France); Pedaletti, G.; Torres, D. F. [Institut de Ciències de l' Espai (IEEE-CSIC), Campus UAB, 08193 Barcelona (Spain); Strong, A. W. [Max-Planck Institut für extraterrestrische Physik, D-85748 Garching (Germany); Yamazaki, R., E-mail: hanabata@icrr.u-tokyo.ac.jp, E-mail: katagiri@mx.ibaraki.ac.jp [Department of Physics and Mathematics, Aoyama Gakuin University, Sagamihara, Kanagawa 252-5258 (Japan)

    2014-05-10

    We present a detailed investigation of the γ-ray emission in the vicinity of the supernova remnant (SNR) W28 (G6.4–0.1) observed by the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. We detected significant γ-ray emission spatially coincident with TeV sources HESS J1800–240A, B, and C, located outside the radio boundary of the SNR. Their spectra in the 2-100 GeV band are consistent with the extrapolation of the power-law spectra of the TeV sources. We also identified a new source of GeV emission, dubbed Source W, which lies outside the boundary of TeV sources and coincides with radio emission from the western part of W28. All of the GeV γ-ray sources overlap with molecular clouds in the velocity range from 0 to 20 km s{sup –1}. Under the assumption that the γ-ray emission toward HESS J1800–240A, B, and C comes from π{sup 0} decay due to the interaction between the molecular clouds and cosmic rays (CRs) escaping from W28, they can be naturally explained by a single model in which the CR diffusion coefficient is smaller than the theoretical expectation in the interstellar space. The total energy of the CRs escaping from W28 is constrained through the same modeling to be larger than ∼2 × 10{sup 49} erg. The emission from Source W can also be explained with the same CR escape scenario.

  5. Detailed investigation of the gamma-ray emission in the vicinity of SNR W28 with Fermi-LAT

    International Nuclear Information System (INIS)

    Hanabata, Y.; Katagiri, H.; Hewitt, J.W.; Ballet, J.; Fukazawa, Y.; Fukui, Y.; Hayakawa, T.; Lemoine-Goumard, M.; Pedaletti, G.; Torres, D. F.; Strong, A. W.; Yamazaki, R.

    2014-01-01

    We present a detailed investigation of the γ-ray emission in the vicinity of the supernova remnant (SNR) W28 (G6.4–0.1) observed by the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. We detected significant γ-ray emission spatially coincident with TeV sources HESS J1800–240A, B, and C, located outside the radio boundary of the SNR. Their spectra in the 2-100 GeV band are consistent with the extrapolation of the power-law spectra of the TeV sources. We also identified a new source of GeV emission, dubbed Source W, which lies outside the boundary of TeV sources and coincides with radio emission from the western part of W28. All of the GeV γ-ray sources overlap with molecular clouds in the velocity range from 0 to 20 km s –1 . Under the assumption that the γ-ray emission toward HESS J1800–240A, B, and C comes from π 0 decay due to the interaction between the molecular clouds and cosmic rays (CRs) escaping from W28, they can be naturally explained by a single model in which the CR diffusion coefficient is smaller than the theoretical expectation in the interstellar space. The total energy of the CRs escaping from W28 is constrained through the same modeling to be larger than ∼2 × 10 49 erg. The emission from Source W can also be explained with the same CR escape scenario.

  6. Determination of /sup 240/Pu//sup 239/Pu ratio in the environmental samples based on the measurement of Lx/. cap alpha. -ray activity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Komura, K.; Sakanoue, M.; Yamamoto, M.

    1984-06-01

    The determination of the /sup 240/Pu//sup 239/Pu isotopic ratio in environmental samples has been attempted by the measurement of the Lx/..cap alpha..-ray activity ratio using a Ge-LEPS (low-energy photon spectrometer) and a surface-barrier Si detector. By this method, interesting data were obtained for various samples collected from Thule, Greenland, Bikini Atoll and Nagasaki, as well as for some soils collected from near and off-site locations of atomic power stations.

  7. Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements

    Science.gov (United States)

    Dippold, Vance F., III

    2016-01-01

    A series of three convergent round-to-rectangular high-aspect ratio nozzles were designed for acoustics measurements. The nozzles have exit area aspect ratios of 8:1, 12:1, and 16:1. With septa inserts, these nozzles will mimic an array of distributed propulsion system nozzles, as found on hybrid wing-body aircraft concepts. Analyses were performed for the three nozzle designs and showed that the flow through the nozzles was free of separated flow and shocks. The exit flow was mostly uniform with the exception of a pair of vortices at each span-wise end of the nozzle.

  8. Extinction-to-Backscatter Ratios of Saharan Dust Layers Derived from In-Situ Measurements and CALIPSO Overflights During NAMMA

    Science.gov (United States)

    Omar, Ali H.; Liu, Zhaoyan; Vaughan, Mark A.; Hu, Yongxiang; Ismail, Syed; Powell, Kathleen A.; Winker, David M.; Trepte, Charles R.; Anderson, Bruce E.

    2010-01-01

    We determine the aerosol extinction-to-backscatter (Sa) ratios of dust using airborne in-situ measurements of microphysical properties, and CALIPSO observations during the NASA African Monsoon Multidisciplinary Analyses (NAMMA). The NAMMA field experiment was conducted from Sal, Cape Verde during Aug-Sept 2006. Using CALIPSO measurements of the attenuated backscatter of lofted Saharan dust layers, we apply the transmittance technique to estimate dust Sa ratios at 532 nm and a 2-color method to determine the corresponding 1064 nm Sa. Using this method, we found dust Sa ratios of 39.8 plus or minus 1.4 sr and 51.8 plus or minus 3.6 sr at 532 nm and 1064 nm, respectively. Secondly, Sa ratios at both wavelengths is independently calculated using size distributions measured aboard the NASA DC-8 and estimates of Saharan dust complex refractive indices applied in a T-Matrix scheme. We found Sa ratios of 39.1 plus or minus 3.5 sr and 50.0 plus or minus 4 sr at 532 nm and 1064 nm, respectively, using the T-Matrix calculations applied to measured size spectra. Finally, in situ measurements of the total scattering (550 nm) and absorption coefficients (532 nm) are used to generate an extinction profile that is used to constrain the CALIPSO 532 nm extinction profile.

  9. Measurement of the nuclear multiplicity ratio for Ks0 hadronization at CLAS

    Science.gov (United States)

    Daniel, A.; Hicks, K.; Brooks, W. K.; Hakobyan, H.; Adhikari, K. P.; Adikaram, D.; Aghasyan, M.; Amarian, M.; Anghinolfi, M.; Avakian, H.; Baghdasaryan, H.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Bennett, R. P.; Biselli, A. S.; Bookwalter, C.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Casey, L.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Dey, B.; Dickson, R.; Djalali, C.; Dodge, G. E.; Doughty, D.; Egiyan, H.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guo, L.; Hanretty, C.; Heddle, D.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jawalkar, S. S.; Jo, H. S.; Joo, K.; Kalantarians, N.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuleshov, S. V.; Kuznetsov, V.; Lu, H. Y.; MacGregor, I. J. D.; Mao, Y.; Markov, N.; Mayer, M.; McAndrew, J.; McKinnon, B.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Moutarde, H.; Munevar, E.; Nadel-Turonski, P.; Ni, A.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Pappalardo, L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Anefalos Pereira, S.; Phelps, E.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Raue, B. A.; Ricco, G.; Rimal, D.; Ripani, M.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vineyard, M. F.; Voskanyan, H.; Voutier, E.; Watts, D. P.; Weinstein, L. B.; Weygand, D. P.; Wood, M. H.; Zana, L.; Zachariou, N.; Zhao, B.; Zhao, Z. W.

    2011-11-01

    The influence of cold nuclear matter on lepto-production of hadrons in semi-inclusive deep inelastic scattering is measured using the CLAS detector in Hall B at Jefferson Lab and a 5.014 GeV electron beam. We report the Ks0 multiplicity ratios for targets of C, Fe, and Pb relative to deuterium as a function of the fractional virtual photon energy z transferred to the Ks0 and the transverse momentum squared pT2 of the Ks0. We find that the multiplicity ratios for Ks0 are reduced in the nuclear medium at high z and low pT2, with a trend for the Ks0 transverse momentum to be broadened in the nucleus for large pT2.

  10. Comparison of a 28 Channel-Receive Array Coil and Quadrature Volume Coil for Morphologic Imaging and T2 Mapping of Knee Cartilage at 7 Tesla

    Science.gov (United States)

    Chang, Gregory; Wiggins, Graham C.; Xia, Ding; Lattanzi, Riccardo; Madelin, Guillaume; Raya, Jose G.; Finnerty, Matthew; Fujita, Hiroyuki; Recht, Michael P.; Regatte, Ravinder R.

    2011-01-01

    Purpose To compare a new birdcage-transmit, 28 channel-receive array (28 Ch) coil and a quadrature volume coil for 7 Tesla morphologic MRI and T2 mapping of knee cartilage. Methods The right knees of ten healthy subjects were imaged on a 7 Tesla whole body MR scanner using both coils. 3-dimensional fast low-angle shot (3D-FLASH) and multi-echo spin-echo (MESE) sequences were implemented. Cartilage signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), thickness, and T2 values were assessed. Results SNR/CNR was 17–400% greater for the 28 Ch compared to the quadrature coil (p≤0.005). Bland-Altman plots show mean differences between measurements of tibial/femoral cartilage thickness and T2 values obtained with each coil to be small (−0.002±0.009 cm/0.003±0.011 cm) and large (−6.8±6.7 ms/−8.2±9.7 ms), respectively. For the 28 Ch coil, when parallel imaging with acceleration factors (AF) 2, 3, and 4 was performed, SNR retained was: 62–69%, 51–55%, and 39–45%. Conclusion A 28 Ch knee coil provides increased SNR/CNR for 7T cartilage morphologic imaging and T2 mapping. Coils should be switched with caution during clinical studies because T2 values may differ. The greater SNR of the 28 Ch coil could be used to perform parallel imaging with AF2 and obtain similar SNR as the quadrature coil. PMID:22095723

  11. Tracer-based laser-induced fluorescence measurement technique for quantitative fuel/air-ratio measurements in a hydrogen internal combustion engine.

    Science.gov (United States)

    Blotevogel, Thomas; Hartmann, Matthias; Rottengruber, Hermann; Leipertz, Alfred

    2008-12-10

    A measurement technique for the quantitative investigation of mixture formation processes in hydrogen internal combustion engines (ICEs) has been developed using tracer-based laser-induced fluorescence (TLIF). This technique can be employed to fired and motored engine operation. The quantitative TLIF fuel/air-ratio results have been verified by means of linear Raman scattering measurements. Exemplary results of the simultaneous investigation of mixture formation and combustion obtained at an optical accessible hydrogen ICE are shown.

  12. Measurement and application of purine derivatives: Creatinine ratio in spot urine samples of ruminants

    International Nuclear Information System (INIS)

    Chen, X.B.; Jayasuriya, M.C.N.; Makkar, H.P.S.

    2004-01-01

    The daily excretion of purine derivatives in urine has been used to estimate the supply of microbial protein to ruminant animals. The method provides a simple and non-invasive tool to indicate the nutritional status of farm animals. However due to the need for complete collection of urine the potential application at farm level is restricted. Research conducted under the FAO/IAEA Co-ordinated Research Project has indicated that it is possible to use the purine derivatives:creatinine ratio measured in several spot urine samples collected within a day, as an index of microbial protein supply in a banding system for farm application. Some theoretical and experimental aspects in the measurement of purine derivatives:creatinine ratio in spot urine samples and the possible application of the banding system at the farm level are discussed. (author)

  13. Pitfalls with the use of enhancement ratios or normalized excess mixing ratios measured in plumes to characterize pollution sources and aging

    Directory of Open Access Journals (Sweden)

    R. J. Yokelson

    2013-08-01

    Full Text Available Normalized excess mixing ratios (NEMRs, also known as enhancement ratios, are a common way to characterize plumes of pollution in atmospheric research. As single-source pollutant plumes disperse in the atmosphere, they are diluted by mixing with the adjacent background air. Changes in the composition of this background air can cause large changes to the NEMR that is subsequently measured by remote-sensing, airborne, or ground-based instruments. This scenario is common when boundary layer plumes enter the free troposphere and could also impact long-range transport or plumes near the top of the troposphere. We provide a context for these issues and an example showing that neglect of this effect could lead to serious errors in data interpretation.

  14. Risk Measure and Early-Warning System of China's Stock Market Based on Price-Earnings Ratio and Price-to-Book Ratio

    Directory of Open Access Journals (Sweden)

    Rongda Chen

    2014-01-01

    Full Text Available Based on the actual situation of China's stock market, this paper proposes a method for measuring the stock market's risk and early-warning methods which are based on price-to-earnings ratio and price-to-book ratio. The study found that the method of VaR can capture the bigger daily drops in a period, and if the drop is at the periodical top of the index, the probability of a sharp index decline will be very high. It also confirmed that the method is feasible and practical for people to use. In the long run, this method really can send early-warning signals of sharp decline; the warning levels increase as the index rises. The study also found that index will not fall after every warning but will continue going forward because of inertia, particularly during a big trend.

  15. Detection of counterfeit antiviral drug Heptodin and classification of counterfeits using isotope amount ratio measurements by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) and isotope ratio mass spectrometry (IRMS).

    Science.gov (United States)

    Santamaria-Fernandez, Rebeca; Hearn, Ruth; Wolff, Jean-Claude

    2009-06-01

    Isotope ratio mass spectrometry (IRMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) are highly important techniques that can provide forensic evidence that otherwise would not be available. MC-ICP-MS has proved to be a very powerful tool for measuring high precision and accuracy isotope amount ratios. In this work, the potential of combining isotope amount ratio measurements performed by MC-ICP-MS and IRMS for the detection of counterfeit pharmaceutical tablets has been investigated. An extensive study for the antiviral drug Heptodin has been performed for several isotopic ratios combining MC-ICP-MS and an elemental analyser EA-IRMS for stable isotope amount ratio measurements. The study has been carried out for 139 batches of the antiviral drug and analyses have been performed for C, S, N and Mg isotope ratios. Authenticity ranges have been obtained for each isotopic system and combined to generate a unique multi-isotopic pattern only present in the genuine tablets. Counterfeit tablets have then been identified as those tablets with an isotopic fingerprint outside the genuine isotopic range. The combination of those two techniques has therefore great potential for pharmaceutical counterfeit detection. A much greater power of discrimination is obtained when at least three isotopic systems are combined. The data from these studies could be presented as evidence in court and therefore methods need to be validated to support their credibility. It is also crucial to be able to produce uncertainty values associated to the isotope amount ratio measurements so that significant differences can be identified and the genuineness of a sample can be assessed.

  16. Intracranial arterial wall imaging using three-dimensional high isotropic resolution black blood MRI at 3.0 Tesla.

    Science.gov (United States)

    Qiao, Ye; Steinman, David A; Qin, Qin; Etesami, Maryam; Schär, Michael; Astor, Brad C; Wasserman, Bruce A

    2011-07-01

    To develop a high isotropic-resolution sequence to evaluate intracranial vessels at 3.0 Tesla (T). Thirteen healthy volunteers and 4 patients with intracranial stenosis were imaged at 3.0T using 0.5-mm isotropic-resolution three-dimensional (3D) Volumetric ISotropic TSE Acquisition (VISTA; TSE, turbo spin echo), with conventional 2D-TSE for comparison. VISTA was repeated for 6 volunteers and 4 patients at 0.4-mm isotropic-resolution to explore the trade-off between SNR and voxel volume. Wall signal-to-noise-ratio (SNR(wall) ), wall-lumen contrast-to-noise-ratio (CNR(wall-lumen) ), lumen area (LA), wall area (WA), mean wall thickness (MWT), and maximum wall thickness (maxWT) were compared between 3D-VISTA and 2D-TSE sequences, as well as 3D images acquired at both resolutions. Reliability was assessed by intraclass correlations (ICC). Compared with 2D-TSE measurements, 3D-VISTA provided 58% and 74% improvement in SNR(wall) and CNR(wall-lumen) , respectively. LA, WA, MWT and maxWT from 3D and 2D techniques highly correlated (ICCs of 0.96, 0.95, 0.96, and 0.91, respectively). CNR(wall-lumen) using 0.4-mm resolution VISTA decreased by 27%, compared with 0.5-mm VISTA but with reduced partial-volume-based overestimation of wall thickness. Reliability for 3D measurements was good to excellent. The 3D-VISTA provides SNR-efficient, highly reliable measurements of intracranial vessels at high isotropic-resolution, enabling broad coverage in a clinically acceptable time. Copyright © 2011 Wiley-Liss, Inc.

  17. Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS.

    Science.gov (United States)

    Kappel, S; Boulyga, S F; Dorta, L; Günther, D; Hattendorf, B; Koffler, D; Laaha, G; Leisch, F; Prohaska, T

    2013-03-01

    Data evaluation is a crucial step when it comes to the determination of accurate and precise isotope ratios computed from transient signals measured by multi-collector-inductively coupled plasma mass spectrometry (MC-ICPMS) coupled to, for example, laser ablation (LA). In the present study, the applicability of different data evaluation strategies (i.e. 'point-by-point', 'integration' and 'linear regression slope' method) for the computation of (235)U/(238)U isotope ratios measured in single particles by LA-MC-ICPMS was investigated. The analyzed uranium oxide particles (i.e. 9073-01-B, CRM U010 and NUSIMEP-7 test samples), having sizes down to the sub-micrometre range, are certified with respect to their (235)U/(238)U isotopic signature, which enabled evaluation of the applied strategies with respect to precision and accuracy. The different strategies were also compared with respect to their expanded uncertainties. Even though the 'point-by-point' method proved to be superior, the other methods are advantageous, as they take weighted signal intensities into account. For the first time, the use of a 'finite mixture model' is presented for the determination of an unknown number of different U isotopic compositions of single particles present on the same planchet. The model uses an algorithm that determines the number of isotopic signatures by attributing individual data points to computed clusters. The (235)U/(238)U isotope ratios are then determined by means of the slopes of linear regressions estimated for each cluster. The model was successfully applied for the accurate determination of different (235)U/(238)U isotope ratios of particles deposited on the NUSIMEP-7 test samples.

  18. A new characterization procedure for computed radiography performance levels based on EPS, SNR and basic spatial resolution measurements

    International Nuclear Information System (INIS)

    Ewert, Uwe; Zscherpel, Uwe; Baer, Sylke

    2016-01-01

    The standards EN 14784-1:2005 and ISO 16371-1:2011 describe the classification of Computed Radiography systems for industrial applications. After 10 years of classification experience, it can be concluded that all certified NDT CR systems achieve the best classification result: IP 1. The measured basic spatial resolution is different depending on the manufacturer's brand and the IP used. Therefore, a revision was recommended to obtain a better gradation for the different brands. Users in USA and Europe classify the CR systems based on different parameters. Consequently, a new revision of ASTM E 2446-15 was finalized in 2015, which describes the characterization of CR systems based on CR performance levels. The key parameters are the normalized Signal to Noise Ratio (SNRN), the interpolated basic spatial resolution (iSR b detector ) and the achieved equivalent penetrameter sensitivity (aEPS). A series of further tests is required for complete characterization by manufacturers or certifying laboratories. This includes e.g.: geometric distortion, laser jitter, PMT non-linearity, scanner slippage, shading or banding, erasure, burn-In, spatial linearity, artefacts, imaging plate response variation and imaging plate fading. ASTM E 2445-15 describes several tests, for users to perform periodic quality assurance. The measurement procedures are described and the resulting values as CR speed, achieved contrast sensitivity and efficiency are discussed. The results will be presented graphically in a spider net graph in the qualification/certification statement. A revision of the related CEN and ISO standards is discussed.

  19. Reduction of determinate errors in mass bias-corrected isotope ratios measured using a multi-collector plasma mass spectrometer

    International Nuclear Information System (INIS)

    Doherty, W.

    2015-01-01

    A nebulizer-centric instrument response function model of the plasma mass spectrometer was combined with a signal drift model, and the result was used to identify the causes of the non-spectroscopic determinate errors remaining in mass bias-corrected Pb isotope ratios (Tl as internal standard) measured using a multi-collector plasma mass spectrometer. Model calculations, confirmed by measurement, show that the detectable time-dependent errors are a result of the combined effect of signal drift and differences in the coordinates of the Pb and Tl response function maxima (horizontal offset effect). If there are no horizontal offsets, then the mass bias-corrected isotope ratios are approximately constant in time. In the absence of signal drift, the response surface curvature and horizontal offset effects are responsible for proportional errors in the mass bias-corrected isotope ratios. The proportional errors will be different for different analyte isotope ratios and different at every instrument operating point. Consequently, mass bias coefficients calculated using different isotope ratios are not necessarily equal. The error analysis based on the combined model provides strong justification for recommending a three step correction procedure (mass bias correction, drift correction and a proportional error correction, in that order) for isotope ratio measurements using a multi-collector plasma mass spectrometer

  20. Preliminary results of oxygen isotope ratio measurement with a particle-gamma coincidence method

    Energy Technology Data Exchange (ETDEWEB)

    Borysiuk, Maciek, E-mail: maciek.borysiuk@pixe.lth.se; Kristiansson, Per; Ros, Linus; Abdel, Nassem S.; Elfman, Mikael; Nilsson, Charlotta; Pallon, Jan

    2015-04-01

    The possibility to study variations in the oxygen isotopic ratio with photon tagged nuclear reaction analysis (pNRA) is evaluated in the current work. The experiment described in the article was performed at Lund Ion Beam Analysis Facility (LIBAF) with a 2 MeV deuteron beam. Isotopic fractionation of light elements such as carbon, oxygen and nitrogen is the basis of many analytical tools in hydrology, geology, paleobiology and paleogeology. IBA methods provide one possible tool for measurement of isotopic content. During this experimental run we focused on measurement of the oxygen isotopic ratio. The measurement of stable isotopes of oxygen has a number of applications; the particular one driving the current investigation belongs to the field of astrogeology and specifically evaluation of fossil extraterrestrial material. There are three stable isotopes of oxygen: {sup 16}O, {sup 17}O and {sup 18}O. We procured samples highly enriched with all three isotopes. Isotopes {sup 16}O and {sup 18}O were easily detected in the enriched samples, but no significant signal from {sup 17}O was detected in the same samples. The measured yield was too low to detect {sup 18}O in a sample with natural abundances of oxygen isotopes, at least in the current experimental setup, but the spectral line from the reaction with {sup 16}O was clearly visible.

  1. Toward a simple, repeatable, non-destructive approach to measuring stable-isotope ratios of water within tree stems

    Science.gov (United States)

    Raulerson, S.; Volkmann, T.; Pangle, L. A.

    2017-12-01

    Traditional methodologies for measuring ratios of stable isotopes within the xylem water of trees involve destructive coring of the stem. A recent approach involves permanently installed probes within the stem, and an on-site assembly of pumps, switching valves, gas lines, and climate-controlled structure for field deployment of a laser spectrometer. The former method limits the possible temporal resolution of sampling, and sample size, while the latter may not be feasible for many research groups. We present results from initial laboratory efforts towards developing a non-destructive, temporally-resolved technique for measuring stable isotope ratios within the xylem flow of trees. Researchers have used direct liquid-vapor equilibration as a method to measure isotope ratios of the water in soil pores. Typically, this is done by placing soil samples in a fixed container, and allowing the liquid water within the soil to come into isotopic equilibrium with the headspace of the container. Water can also be removed via cryogenic distillation or azeotropic distillation, with the resulting liquid tested for isotope ratios. Alternatively, the isotope ratios of the water vapor can be directly measured using a laser-based water vapor isotope analyzer. Well-established fractionation factors and the isotope ratios in the vapor phase are then used to calculate the isotope ratios in the liquid phase. We propose a setup which would install a single, removable chamber onto a tree, where vapor samples could non-destructively and repeatedly be taken. These vapor samples will be injected into a laser-based isotope analyzer by a recirculating gas conveyance system. A major part of what is presented here is in the procedure of taking vapor samples at 100% relative humidity, appropriately diluting them with completely dry N2 calibration gas, and injecting them into the gas conveyance system without inducing fractionation in the process. This methodology will be helpful in making

  2. Residual Resistivity Ratio (RRR) Measurements of LHC Superconducting NbTi Cable Strands

    CERN Document Server

    Charifoulline, Z

    2006-01-01

    The Rutherford-type superconducting NbTi cables of the LHC accelerator are currently manufactured by six industrial companies. As a part of the acceptance tests, the Residual Resistivity Ratio (RRR) of superconducting strands is systematically measured on virgin strands to qualify the strands before cabling and on extracted strands to qualify the cables and to check the final heat treatment (controlled oxidation to control interstrand resistance). More than 12000 samples of virgin and extracted strands have been measured during last five years. Results show good correlation with the measurements done by the companies and reflect well the technological process of cable production (strand annealing, cabling, cable heat treatment). This paper presents a description of the RRR-test station and the measurement procedure, the summary of the results over all suppliers and finally the correlation between RRR-values of the cables and the magnets.

  3. The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial.

    Directory of Open Access Journals (Sweden)

    Sarah Feger

    Full Text Available The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA, reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D and compared to filtered back projection (FBP with quantum denoising software (QDS.Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed using AIDR 3D mild, standard, strong and compared to FBP/QDS. Objective image quality comparison (signal, noise, signal-to-noise ratio (SNR, contrast-to-noise ratio (CNR, contour sharpness was performed using 21 measurement points per patient, including measurements in each coronary artery from proximal to distal.Objective image quality parameters improved with increasing levels of AIDR 3D. Noise was lowest in AIDR 3D strong (p ≤ 0.001 at 20/21 measurement points; compared with FBP/QDS. Signal and contour sharpness analysis showed no significant difference between the reconstruction algorithms for most measurement points. Best coronary SNR and CNR were achieved with AIDR 3D strong. No loss of SNR or CNR in distal segments was seen with AIDR 3D as compared to FBP.On standard-dose coronary CTA images, AIDR 3D strong showed higher objective image quality than FBP/QDS without reducing contour sharpness.Clinicaltrials.gov NCT00967876.

  4. Determination of oral mucosal Poisson's ratio and coefficient of friction from in-vivo contact pressure measurements.

    Science.gov (United States)

    Chen, Junning; Suenaga, Hanako; Hogg, Michael; Li, Wei; Swain, Michael; Li, Qing

    2016-01-01

    Despite their considerable importance to biomechanics, there are no existing methods available to directly measure apparent Poisson's ratio and friction coefficient of oral mucosa. This study aimed to develop an inverse procedure to determine these two biomechanical parameters by utilizing in vivo experiment of contact pressure between partial denture and beneath mucosa through nonlinear finite element (FE) analysis and surrogate response surface (RS) modelling technique. First, the in vivo denture-mucosa contact pressure was measured by a tactile electronic sensing sheet. Second, a 3D FE model was constructed based on the patient CT images. Third, a range of apparent Poisson's ratios and the coefficients of friction from literature was considered as the design variables in a series of FE runs for constructing a RS surrogate model. Finally, the discrepancy between computed in silico and measured in vivo results was minimized to identify the best matching Poisson's ratio and coefficient of friction. The established non-invasive methodology was demonstrated effective to identify such biomechanical parameters of oral mucosa and can be potentially used for determining the biomaterial properties of other soft biological tissues.

  5. Uncertainty assessment in gamma spectrometric measurements of plutonium isotope ratios and age

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H., E-mail: henrik.ramebeck@foi.se [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden); Nygren, U.; Tovedal, A. [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Ekberg, C.; Skarnemark, G. [Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden)

    2012-09-15

    A method for the assessment of the combined uncertainty in gamma spectrometric measurements of plutonium composition and age was evaluated. Two materials were measured. Isotope dilution inductively coupled plasma sector field mass spectrometry (ID-ICP-SFMS) was used as a reference method for comparing the results obtained with the gamma spectrometric method for one of the materials. For this material (weapons grade plutonium) the measurement results were in agreement between the two methods for all measurands. Moreover, the combined uncertainty in all isotope ratios considered in this material (R{sub Pu238/Pu239}, R{sub Pu240/Pu239}, R{sub Pu241/Pu239}, and R{sub Am241/Pu241} for age determination) were limited by counting statistics. However, the combined uncertainty for the other material (fuel grade plutonium) were limited by the response fit, which shows that the uncertainty in the response function is important to include in the combined measurement uncertainty of gamma spectrometric measurements of plutonium.

  6. Two potential hookworm DAF-16 target genes, SNR-3 and LPP-1: gene structure, expression profile, and implications of a cis-regulatory element in the regulation of gene expression.

    Science.gov (United States)

    Gao, Xin; Goggin, Kevin; Dowling, Camille; Qian, Jason; Hawdon, John M

    2015-01-08

    Hookworms infect nearly 700 million people, causing anemia and developmental stunting in heavy infections. Little is known about the genomic structure or gene regulation in hookworms, although recent publication of draft genome assemblies has allowed the first investigations of these topics to be undertaken. The transcription factor DAF-16 mediates multiple developmental pathways in the free living nematode Caenorhabditis elegans, and is involved in the recovery from the developmentally arrested L3 in hookworms. Identification of downstream targets of DAF-16 will provide a better understanding of the molecular mechanism of hookworm infection. Genomic Fragment 2.23 containing a DAF-16 binding element (DBE) was used to identify overlapping complementary expressed sequence tags (ESTs). These sequences were used to search a draft assembly of the Ancylostoma caninum genome, and identified two neighboring genes, snr-3 and lpp-1, in a tail-to-tail orientation. Expression patterns of both genes during parasitic development were determined by qRT-PCR. DAF-16 dependent cis-regulatory activity of fragment 2.23 was investigated using an in vitro reporter system. The snr-3 gene spans approximately 5.6 kb in the genome and contains 3 exons and 2 introns, and contains the DBE in its 3' untranslated region. Downstream from snr-3 in a tail-to-tail arrangement is the gene lpp-1. The lpp-1 gene spans more than 6 kb and contains 10 exons and 9 introns. The A. caninum genome contains 2 apparent splice variants, but there are 7 splice variants in the A. ceylanicum genome. While the gene order is similar, the gene structures of the hookworm genes differ from their C. elegans orthologs. Both genes show peak expression in the late L4 stage. Using a cell culture based expression system, fragment 2.23 was found to have both DAF-16-dependent promoter and enhancer activity that required an intact DBE. Two putative DAF-16 targets were identified by genome wide screening for DAF-16 binding

  7. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy

    Science.gov (United States)

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818

  8. Electron temperature measurement by a helium line intensity ratio method in helicon plasmas

    International Nuclear Information System (INIS)

    Boivin, R.F.; Kline, J.L.; Scime, E.E.

    2001-01-01

    Electron temperature measurements in helicon plasmas are difficult. The presence of intense rf fields in the plasma complicates the interpretation of Langmuir probe measurements. Furthermore, the non-negligible ion temperature in the plasma considerably shortens the lifetime of conventional Langmuir probes. A spectroscopic technique based on the relative intensities of neutral helium lines is used to measure the electron temperature in the HELIX (Hot hELicon eXperiment) plasma [P. A. Keiter et al., Phys. Plasmas 4, 2741 (1997)]. This nonintrusive diagnostic is based on the fact that electron impact excitation rate coefficients for helium singlet and triplet states differ as a function of the electron temperature. The different aspects related to the validity of this technique to measure the electron temperature in rf generated plasmas are discussed in this paper. At low plasma density (n e ≤10 11 cm -3 ), this diagnostic is believed to be very reliable since the population of the emitting level can be easily estimated with reasonable accuracy by assuming that all excitation originates from the ground state (steady-state corona model). At higher density, secondary processes (excitation transfer, excitation from metastable, cascading) become more important and a more complex collisional radiative model must be used to predict the electron temperature. In this work, different helium transitions are examined and a suitable transition pair is identified. For an electron temperature of 10 eV, the line ratio is measured as a function of plasma density and compared to values predicted by models. The measured line ratio function is in good agreement with theory and the data suggest that the excitation transfer is the dominant secondary process in high-density plasmas

  9. A quantitative performance evaluation of the EM algorithm applied to radiographic images

    International Nuclear Information System (INIS)

    Brailean, J.C.; Sullivan, B.J.; Giger, M.L.; Chen, C.T.

    1991-01-01

    In this paper, the authors quantitatively evaluate the performance of the Expectation Maximization (EM) algorithm as a restoration technique for radiographic images. The perceived signal-to-noise ratio (SNR), of simple radiographic patterns processed by the EM algorithm are calculated on the basis of a statistical decision theory model that includes both the observer's visual response function and a noise component internal to the eye-brain system. The relative SNR (ratio of the processed SNR to the original SNR) is calculated and used as a metric to quantitatively compare the effects of the EM algorithm to two popular image enhancement techniques: contrast enhancement (windowing) and unsharp mask filtering

  10. Precision Branching Ratio Measurement for the Superallowed β+ Emitter Ga62 and Isospin-Symmetry-Breaking Corrections in A≥62 Nuclei

    Science.gov (United States)

    Hyland, B.; Svensson, C. E.; Ball, G. C.; Leslie, J. R.; Achtzehn, T.; Albers, D.; Andreoiu, C.; Bricault, P.; Churchman, R.; Cross, D.; Dombsky, M.; Finlay, P.; Garrett, P. E.; Geppert, C.; Grinyer, G. F.; Hackman, G.; Hanemaayer, V.; Lassen, J.; Lavoie, J. P.; Melconian, D.; Morton, A. C.; Pearson, C. J.; Pearson, M. R.; Phillips, A. A.; Schumaker, M. A.; Smith, M. B.; Towner, I. S.; Valiente-Dobón, J. J.; Wendt, K.; Zganjar, E. F.

    2006-09-01

    A high-precision branching ratio measurement for the superallowed β+ decay of Ga62 was performed at the Isotope Separator and Accelerator radioactive ion beam facility. Nineteen γ rays emitted following β+ decay of Ga62 were identified, establishing the dominant superallowed branching ratio to be (99.861±0.011)%. Combined with recent half-life and Q-value measurements, this branching ratio yields a superallowed ft value of 3075.6±1.4s for Ga62 decay. These results demonstrate the feasibility of high-precision superallowed branching ratio measurements in the A≥62 mass region and provide the first stringent tests of the large isospin-symmetry-breaking effects predicted for these decays.

  11. Psycho acoustical Measures in Individuals with Congenital Visual Impairment.

    Science.gov (United States)

    Kumar, Kaushlendra; Thomas, Teenu; Bhat, Jayashree S; Ranjan, Rajesh

    2017-12-01

    In congenital visual impaired individuals one modality is impaired (visual modality) this impairment is compensated by other sensory modalities. There is evidence that visual impaired performed better in different auditory task like localization, auditory memory, verbal memory, auditory attention, and other behavioural tasks when compare to normal sighted individuals. The current study was aimed to compare the temporal resolution, frequency resolution and speech perception in noise ability in individuals with congenital visual impaired and normal sighted. Temporal resolution, frequency resolution, and speech perception in noise were measured using MDT, GDT, DDT, SRDT, and SNR50 respectively. Twelve congenital visual impaired participants with age range of 18 to 40 years were taken and equal in number with normal sighted participants. All the participants had normal hearing sensitivity with normal middle ear functioning. Individual with visual impairment showed superior threshold in MDT, SRDT and SNR50 as compared to normal sighted individuals. This may be due to complexity of the tasks; MDT, SRDT and SNR50 are complex tasks than GDT and DDT. Visual impairment showed superior performance in auditory processing and speech perception with complex auditory perceptual tasks.

  12. WE-EF-210-06: Ultrasound 2D Strain Measurement of Radiation-Induced Toxicity: Phantom and Ex Vivo Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T; Torres, M; Rossi, P; Jani, A; Curran, W; Yang, X [Emory Univ, Atlanta, GA (United States)

    2015-06-15

    Purpose: Radiation-induced fibrosis is a common long-term complication affecting many patients following cancer radiotherapy. Standard clinical assessment of subcutaneous fibrosis is subjective and often limited to visual inspection and palpation. Ultrasound strain imaging describes the compressibility (elasticity) of biological tissues. This study’s purpose is to develop a quantitative ultrasound strain imaging that can consistently and accurately characterize radiation-induce fibrosis. Methods: In this study, we propose a 2D strain imaging method based on deformable image registration. A combined affine and B-spline transformation model is used to calculate the displacement of tissue between pre-stress and post-stress B-mode image sequences. The 2D displacement is estimated through a hybrid image similarity measure metric, which is a combination of the normalized mutual information (NMI) and normalized sum-of-squared-differences (NSSD). And 2D strain is obtained from the gradient of the local displacement. We conducted phantom experiments under various compressions and compared the performance of our proposed method with the standard cross-correlation (CC)- based method using the signal-to-noise (SNR) and contrast-to-noise (CNS) ratios. In addition, we conducted ex-vivo beef muscle experiment to further validate the proposed method. Results: For phantom study, the SNR and CNS values of the proposed method were significantly higher than those calculated from the CC-based method under different strains. The SNR and CNR increased by a factor of 1.9 and 2.7 comparing to the CC-based method. For the ex-vivo experiment, the CC-based method failed to work due to large deformation (6.7%), while our proposed method could accurately detect the stiffness change. Conclusion: We have developed a 2D strain imaging technique based on the deformable image registration, validated its accuracy and feasibility with phantom and ex-vivo data. This 2D ultrasound strain imaging

  13. Odds Ratio Product of Sleep EEG as a Continuous Measure of Sleep State

    Science.gov (United States)

    Younes, Magdy; Ostrowski, Michele; Soiferman, Marc; Younes, Henry; Younes, Mark; Raneri, Jill; Hanly, Patrick

    2015-01-01

    Study Objectives: To develop and validate an algorithm that provides a continuous estimate of sleep depth from the electroencephalogram (EEG). Design: Retrospective analysis of polysomnograms. Setting: Research laboratory. Participants: 114 patients who underwent clinical polysomnography in sleep centers at the University of Manitoba (n = 58) and the University of Calgary (n = 56). Interventions: None. Measurements and Results: Power spectrum of EEG was determined in 3-second epochs and divided into delta, theta, alpha-sigma, and beta frequency bands. The range of powers in each band was divided into 10 aliquots. EEG patterns were assigned a 4-digit number that reflects the relative power in the 4 frequency ranges (10,000 possible patterns). Probability of each pattern occurring in 30-s epochs staged awake was determined, resulting in a continuous probability value from 0% to 100%. This was divided by 40 (% of epochs staged awake) producing the odds ratio product (ORP), with a range of 0–2.5. In validation testing, average ORP decreased progressively as EEG progressed from wakefulness (2.19 ± 0.29) to stage N3 (0.13 ± 0.05). ORP sleep and ORP > 2.0 predicted wakefulness in > 95% of 30-s epochs. Epochs with intermediate ORP occurred in unstable sleep with a high arousal index (> 70/h) and were subject to much interrater scoring variability. There was an excellent correlation (r2 = 0.98) between ORP in current 30-s epochs and the likelihood of arousal or awakening occurring in the next 30-s epoch. Conclusions: Our results support the use of the odds ratio product (ORP) as a continuous measure of sleep depth. Citation: Younes M, Ostrowski M, Soiferman M, Younes H, Younes M, Raneri J, Hanly P. Odds ratio product of sleep EEG as a continuous measure of sleep state. SLEEP 2015;38(4):641–654. PMID:25348125

  14. Constraining the Single-degenerate Channel of Type Ia Supernovae with Stable Iron-group Elements in SNR 3C 397

    Energy Technology Data Exchange (ETDEWEB)

    Dave, Pranav; Kashyap, Rahul; Fisher, Robert [Department of Physics, University of Massachusetts Dartmouth, 285 Old Westport Road, North Dartmouth, MA 02740 (United States); Timmes, Frank [School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287 (United States); Townsley, Dean [Department of Physics and Astronomy, Box 870324, University of Alabama, Tuscaloosa, AL 35487 (United States); Byrohl, Chris [Institut für Astrophysik, Georg August Universität Göttingen, Friedrich-Hund-Platz 1, D-37077 Göttingen (Germany)

    2017-05-20

    Recent Suzaku X-ray spectra of supernova remnant (SNR) 3C 397 indicate enhanced stable iron group element abundances of Ni, Mn, Cr, and Fe. Seeking to address key questions about the progenitor and explosion mechanism of 3C 397, we compute nucleosynthetic yields from a suite of multidimensional hydrodynamics models in the near-Chandrasekhar-mass, single-degenerate paradigm for Type Ia supernovae (SNe Ia). Varying the progenitor white dwarf (WD) internal structure, composition, ignition, and explosion mechanism, we find that the best match to the observed iron peak elements of 3C 397 are dense (central density ≥6 × 10{sup 9} g cm{sup −3}), low-carbon WDs that undergo a weak, centrally ignited deflagration, followed by a subsequent detonation. The amount of {sup 56}Ni produced is consistent with a normal or bright normal SNe Ia. A pure deflagration of a centrally ignited, low central density (≃2 × 10{sup 9} g cm{sup −3}) progenitor WD, frequently considered in the literature, is also found to produce good agreement with 3C 397 nucleosynthetic yields, but leads to a subluminous SN Ia event, in conflict with X-ray line width data. Additionally, in contrast to prior work that suggested a large supersolar metallicity for the WD progenitor for SNR 3C 397, we find satisfactory agreement for solar- and subsolar-metallicity progenitors. We discuss a range of implications our results have for the single-degenerate channel.

  15. Efficient power allocation for fixed-gain amplify-and-forward relaying in rayleigh fading

    KAUST Repository

    Zafar, Ammar; Radaydeh, Redha Mahmoud; Chen, Yunfei; Alouini, Mohamed-Slim

    2013-01-01

    -to-end signal-to-noise ratio (SNR) and 2) minimizing the total consumed power while maintaining the end-to-end SNR over a threshold value. We assume that the relays have knowledge of only the channel statistics of all the links. We show that the SNR maximization

  16. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  17. Evaluating signal-to-noise ratios, loudness, and related measures as indicators of airborne sound insulation.

    Science.gov (United States)

    Park, H K; Bradley, J S

    2009-09-01

    Subjective ratings of the audibility, annoyance, and loudness of music and speech sounds transmitted through 20 different simulated walls were used to identify better single number ratings of airborne sound insulation. The first part of this research considered standard measures such as the sound transmission class the weighted sound reduction index (R(w)) and variations of these measures [H. K. Park and J. S. Bradley, J. Acoust. Soc. Am. 126, 208-219 (2009)]. This paper considers a number of other measures including signal-to-noise ratios related to the intelligibility of speech and measures related to the loudness of sounds. An exploration of the importance of the included frequencies showed that the optimum ranges of included frequencies were different for speech and music sounds. Measures related to speech intelligibility were useful indicators of responses to speech sounds but were not as successful for music sounds. A-weighted level differences, signal-to-noise ratios and an A-weighted sound transmission loss measure were good predictors of responses when the included frequencies were optimized for each type of sound. The addition of new spectrum adaptation terms to R(w) values were found to be the most practical approach for achieving more accurate predictions of subjective ratings of transmitted speech and music sounds.

  18. Interstellar protons in the TeV γ-ray SNR HESS J1731-347: Possible evidence for the coexistence of hadronic and leptonic γ-rays

    International Nuclear Information System (INIS)

    Fukuda, T.; Yoshiike, S.; Sano, H.; Torii, K.; Yamamoto, H.; Fukui, Y.; Acero, F.

    2014-01-01

    HESS J1731-347 (G353.6-0.7) is one of the TeV γ-ray supernova remnants (SNRs) that shows the shell-like morphology. We have made a new analysis of the interstellar protons toward the SNR by using both the 12 CO(J = 1-0) and H I data sets. The results indicate that the TeV γ-ray shell shows significant spatial correlation with the interstellar protons at a velocity range from –90 km s –1 to –75 km s –1 . The total mass of the interstellar medium (ISM) protons is estimated to be 6.4 × 10 4 M ☉ , 25% of which is atomic gas, and the distance corresponding to the velocity range is ∼5.2 kpc, a factor of 2 larger than the previous figure, 3 kpc. We have identified the cold H I gas observed as self-absorption which shows significant correspondence with the northeastern γ-ray peak. While the good correspondence between the ISM protons and TeV γ-rays in the north of the SNR lends support to the hadronic scenario for the TeV γ-rays, the southern part of the shell shows a break in the correspondence; in particular, the southwestern rim of the SNR shell shows a significant decrease of the interstellar protons by a factor of two. We argue that this discrepancy can be explained due to leptonic γ-rays because this region coincides well with the bright shell that emits non-thermal radio continuum emission and non-thermal X-rays, suggesting that the γ-rays of HESS J1713-347 consist of both the hadronic and leptonic components. The leptonic contribution corresponds to ∼20% of the total γ-rays.

  19. A measurement of the {psi}' to J/{psi} production ratio in 920 GeV proton-nucleus interactions

    Energy Technology Data Exchange (ETDEWEB)

    Abt, I. [Max-Planck-Institut fuer Physik, Werner-Heisenberg-Institut, Muenchen (Germany); Adams, M. [Dortmund Univ. (Germany). Inst. fuer Physik; Agari, M. [Max-Planck-Institut fuer Kernphysik, Heidelberg (DE)] (and others)

    2006-07-15

    Ratios of the {psi}' over the J/{psi} production cross sections in the dilepton channel for C, Ti and W targets have been measured in 920 GeV proton-nucleus interactions with the HERA-B detector at the HERA storage ring. The {psi}' and J/{psi} states were reconstructed in both the {mu}{sup +}{mu}{sup -} and the e{sup +}e{sup -} decay modes. The measurements covered the kinematic range -0.35{<=}x{sub F}{<=}0.1 with transverse momentum p{sub T}{<=}4.5 GeV/c. The {psi}' to J/{psi} production ratio is almost constant in the covered x{sub F} range and shows a slow increase with p{sub T}. The angular dependence of the ratio has been used to measure the difference of the {psi}' and J/{psi} polarization. All results for the muon and electron decay channels are in good agreement: their ratio, averaged over all events, is R{sub {psi}}{sub '}({mu})/R{sub {psi}}{sub '}(e)=1.00{+-}0.08{+-}0.04. This result constitutes a new, direct experimental constraint on the double ratio of branching fractions, (B'({mu}).B(e))/(B({mu}).B'(e)), of {psi}'' and J/{psi} in the two channels. (orig.)

  20. Sensitivity, stability, and precision of quantitative Ns-LIBS-based fuel-air-ratio measurements for methane-air flames at 1-11 bar.

    Science.gov (United States)

    Hsu, Paul S; Gragston, Mark; Wu, Yue; Zhang, Zhili; Patnaik, Anil K; Kiefer, Johannes; Roy, Sukesh; Gord, James R

    2016-10-01

    Nanosecond laser-induced breakdown spectroscopy (ns-LIBS) is employed for quantitative local fuel-air (F/A) ratio (i.e., ratio of actual fuel-to-oxidizer mass over ratio of fuel-to-oxidizer mass at stoichiometry, measurements in well-characterized methane-air flames at pressures of 1-11 bar). We selected nitrogen and hydrogen atomic-emission lines at 568 nm and 656 nm, respectively, to establish a correlation between the line intensities and the F/A ratio. We have investigated the effects of laser-pulse energy, camera gate delay, and pressure on the sensitivity, stability, and precision of the quantitative ns-LIBS F/A ratio measurements. We determined the optimal laser energy and camera gate delay for each pressure condition and found that measurement stability and precision are degraded with an increase in pressure. We have identified primary limitations of the F/A ratio measurement employing ns-LIBS at elevated pressures as instabilities caused by the higher density laser-induced plasma and the presence of the higher level of soot. Potential improvements are suggested.

  1. Determination of K shell absorption jump factors and jump ratios of 3d transition metals by measuring K shell fluorescence parameters.

    Science.gov (United States)

    Kaçal, Mustafa Recep; Han, İbrahim; Akman, Ferdi

    2015-01-01

    Energy dispersive X-ray fluorescence technique (EDXRF) has been employed for measuring K-shell absorption jump factors and jump ratios for Ti, Cr, Fe, Co, Ni and Cu elements. The jump factors and jump ratios for these elements were determined by measuring K shell fluorescence parameters such as the Kα X-ray production cross-sections, K shell fluorescence yields, Kβ-to-Kα X-rays intensity ratios, total atomic absorption cross sections and mass attenuation coefficients. The measurements were performed using a Cd-109 radioactive point source and an Si(Li) detector in direct excitation and transmission experimental geometry. The measured values for jump factors and jump ratios were compared with theoretically calculated and the ones available in the literature. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Measurement of the Branching Ratio Lambda_c+ -> p pi+ pi-

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Hinojosa, Guillermo; /San Luis Potosi U.

    2008-03-01

    The confirmation of the Cabibbo-suppressed charm baryon decay mode {Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -} is reported. All data analyzed are from SELEX, a fixed target experiment at Fermilab that took data during 1996 and 1997, mainly with a 600 GeV/c {Sigma}{sup -} beam. The branching ratio of the Cabibbo-suppressed decay mode {Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -} relative to the Cabibbo-favored mode {Lambda}{sub c}{sup +} {yields} pK{sup -}{pi}{sup +} is measured to be: {Gamma}({Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -})/{Gamma}({Lambda}{sub c}{sup +} {yields} pK{sup -}{pi}{sup +}) = 0.103 {+-} 0.022.

  3. Measurements of volatile organic compounds at a suburban ground site (T1 in Mexico City during the MILAGRO 2006 campaign: measurement comparison, emission ratios, and source attribution

    Directory of Open Access Journals (Sweden)

    D. M. Bon

    2011-03-01

    Full Text Available Volatile organic compound (VOC mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS quantified 12 VOC species including oxygenated VOCs (OVOCs and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs relative to CO are derived from early-morning measurements. Average emission ratios for non-oxygenated species relative to CO are on average a factor of ~2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF is used to provide insight into VOC sources and processing. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. Emission ratios to CO calculated from the results of PMF analysis are compared to emission ratios calculated directly from measurements. The total PIT-MS signal is summed to estimate the fraction of identified versus unidentified VOC species.

  4. Measurements of volatile organic compounds at a suburban ground site (T1) in Mexico City during the MILAGRO 2006 campaign: Measurement comparison, emission ratios, and source attribution

    Energy Technology Data Exchange (ETDEWEB)

    Bon, D.M.; Springston, S.; M.Ulbrich, I.; de Gouw, J. A.; Warneke, C.; Kuster, W. C.; Alexander, M. L.; Baker, A.; Beyersdorf, A. J.; Blake, D.; Fall, R.; Jimenez, J. L., Herndon, S. C.; Huey, L. G.; Knighton, W. B.; Ortega, J.; Vargas, O.

    2011-03-16

    Volatile organic compound (VOC) mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO) campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID) quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS) quantified 12 VOC species including oxygenated VOCs (OVOCs) and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS) to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS) deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG) emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs relative to CO are derived from early-morning measurements. Average emission ratios for non-oxygenated species relative to CO are on average a factor of {approx}2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF) is used to provide insight into VOC sources and processing. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. Emission ratios to CO calculated from the results of PMF analysis are compared to emission ratios calculated directly from measurements. The total PIT-MS signal is summed to estimate the fraction of identified versus unidentified VOC species.

  5. Preliminary study of the α ratio measurement, ratio of the neutron capture cross section to the fission one for 233U, on the PEREN platform. Development and study of the experimental setup

    International Nuclear Information System (INIS)

    Cognet, M.A.

    2007-12-01

    Producing nuclear energy in order to reduce anthropic CO 2 emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of 233 U, ratio of the neutron capture cross section to fission one for 233 U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of 233 U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is composed of a lead slowing-down time spectrometer associated with an intense pulsed neutron generator. Capture and fission rates are measured thanks to eight scintillators with their photomultipliers, surrounding a fission chamber. A software analysis sets the coincidence rate between the scintillators. In order to understand perfectly the experimental setup, preliminary tests using a 235 U fission chamber have been done. This experiment resulted in a very low signal to background ratio (1 %). The background coming from the scintillators themselves seriously handicapped the measurement. Another series of experiment has been done with scintillators 5 times thinner. Nevertheless, the signal to background ratio should still be increased to measure the capture of 235 U. To make sure that the experimental setup has totally been understood, we made many comparisons between experimental results and simulations. Two simulation codes were mainly used: MCNP and GEANT4. We paid special attention to quantify the

  6. Evaluation of skeletal muscle DTI in patients with duchenne muscular dystrophy.

    Science.gov (United States)

    Hooijmans, M T; Damon, B M; Froeling, M; Versluis, M J; Burakiewicz, J; Verschuuren, J J G M; Niks, E H; Webb, A G; Kan, H E

    2015-11-01

    Diffusion tensor imaging (DTI) is a popular method to assess differences in fiber organization in diseased and healthy muscle tissue. Previous work has shown that muscle DTI measurements depend on signal-to-noise ratio (SNR), %fat, and tissue T2. The goal of this study was to evaluate the potential biasing effects of these factors on skeletal muscle DTI data in patients with Duchenne Muscular Dystrophy (DMD). MR images were obtained of the right lower leg of 21 DMD patients and 12 healthy controls on a Philips 3T system. DTI measurements were combined with quantitative in-vivo measures of mean water T2, %fat and SNR to evaluate their effect on DTI parameter estimation. All outcome measures were determined within ROIs drawn for six lower leg muscles. Between group analysis, using all ROIs, revealed a significantly elevated FA in the GCL, SOL and PER muscles (pDTI parameter estimation. These findings suggest that measuring mean water T2, %fat and SNR is essential to ascribe changes in DTI measures to intrinsic diffusion changes or to confounding influences. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Equilibrium gas-oil ratio measurements using a microfluidic technique.

    Science.gov (United States)

    Fisher, Robert; Shah, Mohammad Khalid; Eskin, Dmitry; Schmidt, Kurt; Singh, Anil; Molla, Shahnawaz; Mostowfi, Farshid

    2013-07-07

    A method for measuring the equilibrium GOR (gas-oil ratio) of reservoir fluids using microfluidic technology is developed. Live crude oils (crude oil with dissolved gas) are injected into a long serpentine microchannel at reservoir pressure. The fluid forms a segmented flow as it travels through the channel. Gas and liquid phases are produced from the exit port of the channel that is maintained at atmospheric conditions. The process is analogous to the production of crude oil from a formation. By using compositional analysis and thermodynamic principles of hydrocarbon fluids, we show excellent equilibrium between the produced gas and liquid phases is achieved. The GOR of a reservoir fluid is a key parameter in determining the equation of state of a crude oil. Equations of state that are commonly used in petroleum engineering and reservoir simulations describe the phase behaviour of a fluid at equilibrium state. Therefore, to accurately determine the coefficients of an equation of state, the produced gas and liquid phases have to be as close to the thermodynamic equilibrium as possible. In the examples presented here, the GORs measured with the microfluidic technique agreed with GOR values obtained from conventional methods. Furthermore, when compared to conventional methods, the microfluidic technique was simpler to perform, required less equipment, and yielded better repeatability.

  8. Determination of K shell absorption jump factors and jump ratios of 3d transition metals by measuring K shell fluorescence parameters

    International Nuclear Information System (INIS)

    Kaçal, Mustafa Recep; Han, İbrahim; Akman, Ferdi

    2015-01-01

    Energy dispersive X-ray fluorescence technique (EDXRF) has been employed for measuring K-shell absorption jump factors and jump ratios for Ti, Cr, Fe, Co, Ni and Cu elements. The jump factors and jump ratios for these elements were determined by measuring K shell fluorescence parameters such as the Kα X-ray production cross-sections, K shell fluorescence yields, Kβ-to-Kα X-rays intensity ratios, total atomic absorption cross sections and mass attenuation coefficients. The measurements were performed using a Cd-109 radioactive point source and an Si(Li) detector in direct excitation and transmission experimental geometry. The measured values for jump factors and jump ratios were compared with theoretically calculated and the ones available in the literature. - Highlights: • This work regard the K shell absorption jump ratios and jump factors of Ti, Cr, Fe, Co, Ni and Cu. • This paper presents the first measurement of these parameters using the experimental K shell fluorescence parameters. • A good agreement was found between experimental and theoretical values. • The EDXRF technique was suitable, precise and reliable for the measurement of these atomic parameters

  9. Ozone mixing ratios inside tropical deep convective clouds from OMI satellite measurements

    Directory of Open Access Journals (Sweden)

    J. R. Ziemke

    2009-01-01

    Full Text Available We have developed a new technique for estimating ozone mixing ratio inside deep convective clouds. The technique uses the concept of an optical centroid cloud pressure that is indicative of the photon path inside clouds. Radiative transfer calculations based on realistic cloud vertical structure as provided by CloudSat radar data show that because deep convective clouds are optically thin near the top, photons can penetrate significantly inside the cloud. This photon penetration coupled with in-cloud scattering produces optical centroid pressures that are hundreds of hPa inside the cloud. We combine measured column ozone and the optical centroid cloud pressure derived using the effects of rotational-Raman scattering to estimate O3 mixing ratio in the upper regions of deep convective clouds. The data are obtained from the Ozone Monitoring Instrument (OMI onboard NASA's Aura satellite. Our results show that low O3 concentrations in these clouds are a common occurrence throughout much of the tropical Pacific. Ozonesonde measurements in the tropics following convective activity also show very low concentrations of O3 in the upper troposphere. These low amounts are attributed to vertical injection of ozone poor oceanic boundary layer air during convection into the upper troposphere followed by convective outflow. Over South America and Africa, O3 mixing ratios inside deep convective clouds often exceed 50 ppbv which are comparable to mean background (cloud-free amounts and are consistent with higher concentrations of injected boundary layer/lower tropospheric O3 relative to the remote Pacific. The Atlantic region in general also consists of higher amounts of O3 precursors due to both biomass burning and lightning. Assuming that O3 is well mixed (i.e., constant mixing ratio with height up to the tropopause, we can estimate the stratospheric column O3 over

  10. Noise Measurements of High Aspect Ratio Distributed Exhaust Systems

    Science.gov (United States)

    Bridges, James E.

    2015-01-01

    This paper covers far-field acoustic measurements of a family of rectangular nozzles with aspect ratio 8, in the high subsonic flow regime. Several variations of nozzle geometry, commonly found in embedded exhaust systems, are explored, including bevels, slants, single broad chevrons and notches, and internal septae. Far-field acoustic results, presented previously for the simple rectangular nozzle, showed that increasing aspect ratio increases the high frequency noise, especially directed in the plane containing the minor axis of the nozzle. Detailed changes to the nozzle geometry generally made little difference in the noise, and the differences were greatest at low speed. Having an extended lip on one broad side (bevel) did produce up to 3 decibels more noise in all directions, while extending the lip on the narrow side (slant) produced up to 2 decibels more noise, primarily on the side with the extension. Adding a single, non-intrusive chevron, made no significant change to the noise, while inverting the chevron (notch) produced up to 2decibels increase in the noise. Having internal walls (septae) within the nozzle, such as would be required for structural support or when multiple fan ducts are aggregated, reduced the noise of the rectangular jet, but could produce a highly directional shedding tone from the septae trailing edges. Finally, a nozzle with both septae and a beveled nozzle, representative of the exhaust system envisioned for a distributed electric propulsion aircraft with a common rectangular duct, produced almost as much noise as the beveled nozzle, with the septae not contributing much reduction in noise.

  11. Gross Motor Function Measure Evolution Ratio: Use as a Control for Natural Progression in Cerebral Palsy.

    Science.gov (United States)

    Marois, Pierre; Marois, Mikael; Pouliot-Laforte, Annie; Vanasse, Michel; Lambert, Jean; Ballaz, Laurent

    2016-05-01

    To develop a new way to interpret Gross Motor Function Measure (GMFM-66) score improvement in studies conducted without control groups in children with cerebral palsy (CP). The curves, which describe the pattern of motor development according to the children's Gross Motor Function Classification System level, were used as historical control to define the GMFM-66 expected natural evolution in children with CP. These curves have been modeled and generalized to fit the curve to particular children characteristics. Research center. Not applicable. Not applicable. Not applicable. Assuming that the GMFM-66 score evolution followed the shape of the Rosenbaum curves, by taking into account the age and GMFM-66 score of children, the expected natural evolution of the GMFM-66 score was predicted for any group of children with CP who were Ratio, was defined as follows: Gross Motor Function Measure Evolution Ratio=measured GMFM-66 score change/expected natural evolution. For practical or ethical reasons, it is almost impossible to use control groups in studies evaluating effectiveness of many therapeutic modalities. The Gross Motor Function Measure Evolution Ratio gives the opportunity to take into account the expected natural evolution of the gross motor function of children with CP, which is essential to accurately interpret the therapy effect on the GMFM-66. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. Isotopic ratio measurement using a double focusing magnetic sector mass analyser with an inductively coupled plasma as an ion source

    International Nuclear Information System (INIS)

    Walder, A.J.; Freedman, P.A.

    1992-01-01

    An inductively coupled plasma source was coupled to a magnetic sector mass analyser equipped with seven Faraday detectors. An electrostatic filter located between the plasma source and the magnetic sector was used to create a double focusing system. Isotopic ratio measurements of uranium and lead standards revealed levels of internal and external precision comparable to those obtained using thermal inonization mass spectrometry. An external precision of 0.014% was obtained from the 235 U: 238 U measurement of six samples of a National Bureau of Standards (NBS) Standard Reference Material (SRM) U-500, while an RSD of 0.022% was obtained from the 206 Pb: 204 Pb measurement of six samples of NBS SRM Pb-981. Measured isotopic ratios deviated from the NBS value by approximately 0.9% per atomic mass unit. This deviation approximates to a linear function of mass bias and can therefore be corrected for by the analysis of standards. The analysis of NBS SRM Sr-987 revealed superior levels of internal and external precision. The normalization of the 87 Sr: 86 Sr ratio to the 86 Sr: 88 Sr ratio reduced the RSD to approximately 0.008%. The measured ratio was within 0.01% of the NBS value and the day-to-day reproducibility was consistent within one standard deviation. (author)

  13. Prospect for measuring the branching ratio of $B_{s}\\rightarrow\\mu\\mu$ at LHC$b$

    CERN Document Server

    Lopez Asamar, E

    2009-01-01

    The Standard Model predicts a branching ratio for the decay mode $B_{s}\\rightarrow\\mu\\mu$ of (3.32$\\pm$0.32)$\\times$10 $^{-9}$ while some SUSY models predict enhancements of up to 2 orders of magnitude. It is expected that at the end of its life the Tevatron will set an exclusion limit for this branching ratio of the order of 10 $^{-8}$, leaving one order of magnitude to explore. The efficient trigger, excellent vertex reconstruction and invariant mass resolution, and muon identification of the LHC$b$ detector makes it well suited to observe a branching ratio in this range in the first years of running of the LHC. In this article an overview of the analysis that has been developed for the measurement of this branching ratio is presented. The event selection and the statistical tools used for the extraction of the branching ratio are discussed. Special emphasis is placed on the use of control channels for calibration and normalization in order to make the analysis as independent of simulation as possible. Fina...

  14. Continuous-flow isotope ratio mass spectrometry method for carbon and hydrogen isotope measurements on atmospheric methane

    Directory of Open Access Journals (Sweden)

    M. Brass

    2010-12-01

    Full Text Available We describe a continuous-flow isotope ratio mass spectrometry (CF-IRMS technique for high-precision δD and δ13C measurements of atmospheric methane on 40 mL air samples. CH4 is separated from other air components by utilizing purely physical processes based on temperature, time and mechanical valve switching. Chemical agents are avoided. Trace amounts of interfering compounds can be separated by gas chromatography after pre-concentration of the CH4 sample. The purified sample is then either combusted to CO2 or pyrolyzed to H2 for stable isotope measurement. Apart from connecting samples and refilling liquid nitrogen as coolant the system is fully automated and allows an unobserved, continuous analysis of samples. The analytical system has been used for analysis of air samples with CH4 mixing ratios between ~100 and ~10 000 ppb, for higher mixing ratios samples usually have to be diluted.

  15. Measurement of the ratio σ{tt}/σ{Z/γ{*}→ll} and precise extraction of the tt cross section.

    Science.gov (United States)

    Aaltonen, T; Adelman, J; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauer, G; Beauchemin, P-H; Bedeschi, F; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Chung, K; Chung, W H; Chung, Y S; Chwalek, T; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; d'Errico, M; Di Canto, A; di Giovanni, G P; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, T; Dube, S; Ebina, K; Elagin, A; Erbacher, R; Errede, D; Errede, S; Ershaidat, N; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Group, R C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hartz, M; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Hughes, R E; Hurwitz, M; Husemann, U; Hussein, M; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, H W; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kuhr, T; Kulkarni, N P; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leone, S; Lewis, J D; Lin, C-J; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Lovas, L; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, V; Martínez, M; Martínez-Ballarín, R; Mastrandrea, P; Mathis, M; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Mesropian, C; Miao, T; Mietlicki, D; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Neubauer, S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Osterberg, K; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramanov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Peiffer, T; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Potamianos, K; Poukhov, O; Prokoshin, F; Pronko, A; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Renz, M; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Rutherford, B; Saarikko, H; Safonov, A; Sakumoto, W K; Santi, L; Sartori, L; Sato, K; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sforza, F; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Simonenko, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Suh, J S; Sukhanov, A; Suslov, I; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Tipton, P; Ttito-Guzmán, P; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Trovato, M; Tsai, S-Y; Tu, Y; Turini, N; Ukegawa, F; Uozumi, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vogel, M; Volobouev, I; Volpi, G; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wagner-Kuhr, J; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Weinelt, J; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wolfe, H; Wright, T; Wu, X; Würthwein, F; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhang, X; Zheng, Y; Zucchelli, S

    2010-07-02

    We report a measurement of the ratio of the tt to Z/γ{*} production cross sections in sqrt[s]=1.96  TeV pp collisions using data corresponding to an integrated luminosity of up to 4.6  fb{-1}, collected by the CDF II detector. The tt cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/γ{*}→ll cross section predicted by the standard model, the extracted tt cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result σ{tt}=7.70±0.52  pb, for a top-quark mass of 172.5  GeV/c{2}.

  16. Forensic analysis of explosives using isotope ratio mass spectrometry (IRMS)--part 1: instrument validation of the DELTAplusXP IRMS for bulk nitrogen isotope ratio measurements.

    Science.gov (United States)

    Benson, Sarah J; Lennard, Christopher J; Hill, David M; Maynard, Philip; Roux, Claude

    2010-01-01

    A significant amount of research has been conducted into the use of stable isotopes to assist in determining the origin of various materials. The research conducted in the forensic field shows the potential of isotope ratio mass spectrometry (IRMS) to provide a level of discrimination not achievable utilizing traditional forensic techniques. Despite the research there have been few, if any, publications addressing the validation and measurement uncertainty of the technique for forensic applications. This study, the first in a planned series, presents validation data for the measurement of bulk nitrogen isotope ratios in ammonium nitrate (AN) using the DELTA(plus)XP (Thermo Finnigan) IRMS instrument equipped with a ConFlo III interface and FlashEA 1112 elemental analyzer (EA). Appropriate laboratory standards, analytical methods and correction calculations were developed and evaluated. A validation protocol was developed in line with the guidelines provided by the National Association of Testing Authorities, Australia (NATA). Performance characteristics including: accuracy, precision/repeatability, reproducibility/ruggedness, robustness, linear range, and measurement uncertainty were evaluated for the measurement of nitrogen isotope ratios in AN. AN (99.5%) and ammonium thiocyanate (99.99+%) were determined to be the most suitable laboratory standards and were calibrated against international standards (certified reference materials). All performance characteristics were within an acceptable range when potential uncertainties, including the manufacturer's uncertainty of the technique and standards, were taken into account. The experiments described in this article could be used as a model for validation of other instruments for similar purposes. Later studies in this series will address the more general issue of demonstrating that the IRMS technique is scientifically sound and fit-for-purpose in the forensic explosives analysis field.

  17. High precision measurements of carbon isotopic ratio of atmospheric methane using a continuous flow mass spectrometer

    Directory of Open Access Journals (Sweden)

    Shinji Morimoto

    2009-03-01

    Full Text Available A high-precision measurement system for the carbon isotope ratio of atmospheric CH4 (δ^(13CH_4 was developed using a pre-concentration device for CH4 and a gas chromatograph-combustion-isotope ratio mass spectrometer (GC-C-IRMS. The measurement system required 100 mlSTP of an atmospheric air sample, corresponding to approximately 0.18μlSTP of CH_4, to determine the δ^(13CH_4 value with a reproducibility of 0.07‰. Replicated analyses of a CH_4-in-air standard gas during the period from 2002 to 2008 indicated that the value of δ^(13CH_4 measured by this system was consistent within the measurement reproducibility. To evaluate the δ^(13CH_4 measurement system, thus developed, diurnal variations of the atmospheric CH_4 concentration and δ^(13CH_4 were observed in the northern part of the Tokyo metropolitan area. From the relationship between the CH_4 concentration and δ^(13CH_4, dominant sources of the observed CH4 fluctuations were identified.

  18. The fast ratio: A rapid measure for testing the dominance of the fast component in the initial OSL signal from quartz

    International Nuclear Information System (INIS)

    Durcan, Julie A.; Duller, Geoff A.T.

    2011-01-01

    The signal from the fast component is usually considered preferable for quartz optically stimulated luminescence (OSL) dating, however its presence in a continuous wave (CW) OSL signal is often assumed, rather than verified. This paper presents an objective measure (termed the fast ratio) for testing the dominance of the fast component in the initial part of a quartz OSL signal. The ratio is based upon the photo ionisation cross-sections of the fast and medium components and the power of the measurement equipment used to record the OSL signal, and it compares parts of the OSL signal selected to represent the fast and medium components. The ability of the fast ratio to distinguish between samples whose CW-OSL signal is dominated by the fast and non-fast components is demonstrated by comparing the fast ratio with the contribution of the fast component calculated from curve deconvolution of measured OSL signals and from simulated data. The ratio offers a rapid method for screening a large number of OSL signals obtained for individual equivalent dose estimates, it can be calculated and applied as easily as other routine screening methods, and is transferrable between different aliquots, samples and measurement equipment. - Highlights: → Fast ratio is a measure which tests dominance of fast component in quartz OSL signals. → A fast ratio above 20 implies a CW-OSL signal is dominated by fast component. → Fast ratio can be easily and rapidly applied to a large number of OSL signals. → Uses include signal comparison, data screening, identify need for further analysis.

  19. Measuring listening-related effort and fatigue in school-aged children using pupillometry.

    Science.gov (United States)

    McGarrigle, Ronan; Dawes, Piers; Stewart, Andrew J; Kuchinsky, Stefanie E; Munro, Kevin J

    2017-09-01

    Stress and fatigue from effortful listening may compromise well-being, learning, and academic achievement in school-aged children. The aim of this study was to investigate the effect of a signal-to-noise ratio (SNR) typical of those in school classrooms on listening effort (behavioral and pupillometric) and listening-related fatigue (self-report and pupillometric) in a group of school-aged children. A sample of 41 normal-hearing children aged 8-11years performed a narrative speech-picture verification task in a condition with recommended levels of background noise ("ideal": +15dB SNR) and a condition with typical classroom background noise levels ("typical": -2dB SNR). Participants showed increased task-evoked pupil dilation in the typical listening condition compared with the ideal listening condition, consistent with an increase in listening effort. No differences were found between listening conditions in terms of performance accuracy and response time on the behavioral task. Similarly, no differences were found between listening conditions in self-report and pupillometric markers of listening-related fatigue. This is the first study to (a) examine listening-related fatigue in children using pupillometry and (b) demonstrate physiological evidence consistent with increased listening effort while listening to spoken narratives despite ceiling-level task performance accuracy. Understanding the physiological mechanisms that underpin listening-related effort and fatigue could inform intervention strategies and ultimately mitigate listening difficulties in children. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Stochastic Dominance and Omega Ratio: Measures to Examine Market Efficiency, Arbitrage Opportunity, and Anomaly

    Directory of Open Access Journals (Sweden)

    Xu Guo

    2017-10-01

    Full Text Available Both stochastic dominance and Omegaratio can be used to examine whether the market is efficient, whether there is any arbitrage opportunity in the market and whether there is any anomaly in the market. In this paper, we first study the relationship between stochastic dominance and the Omega ratio. We find that second-order stochastic dominance (SD and/or second-order risk-seeking SD (RSD alone for any two prospects is not sufficient to imply Omega ratio dominance insofar that the Omega ratio of one asset is always greater than that of the other one. We extend the theory of risk measures by proving that the preference of second-order SD implies the preference of the corresponding Omega ratios only when the return threshold is less than the mean of the higher return asset. On the other hand, the preference of the second-order RSD implies the preference of the corresponding Omega ratios only when the return threshold is larger than the mean of the smaller return asset. Nonetheless, first-order SD does imply Omega ratio dominance. Thereafter, we apply the theory developed in this paper to examine the relationship between property size and property investment in the Hong Kong real estate market. We conclude that the Hong Kong real estate market is not efficient and there are expected arbitrage opportunities and anomalies in the Hong Kong real estate market. Our findings are useful for investors and policy makers in real estate.

  1. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    Science.gov (United States)

    Sato, K.; Kobayashi, Y.

    2015-05-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

  2. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    International Nuclear Information System (INIS)

    Sato, K.; Kobayashi, Y.

    2015-01-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed

  3. Mass spectrometric measurement of urinary kynurenine-to-tryptophan ratio in children with and without urinary tract infection.

    Science.gov (United States)

    Yarbrough, Melanie L; Briden, Kelleigh E; Mitsios, John V; Weindel, Annette L; Terrill, Cindy M; Hunstad, David A; Dietzen, Dennis J

    2018-04-19

    Indoleamine-2,3-dioxygenase (IDO) catalyzes the first step of tryptophan (Trp) catabolism, yielding kynurenine (Kyn) metabolites. The kynurenine-to-tryptophan (K/T) ratio is used as a surrogate for biological IDO enzyme activity. IDO expression is increased during Escherichia coli urinary tract infection (UTI). Thus, our objective was to develop a method for measurement of Kyn/Trp ratio in human blood and urine and evaluate its use as a biomarker of UTI. A mass spectrometric method was developed to measure Trp and Kyn in serum and urine specimens. The method was applied to clinical urine specimens from symptomatic pediatric patients with laboratory-confirmed UTI or other acute conditions and from healthy controls. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was linear to 500 μmol/L for both Trp and Kyn. Imprecision ranged from 5 to 15% for Trp and 6-20% for Kyn. Analytical recoveries of Trp and Kyn ranged from 96 to 119% in serum and 90-97% in urine. No correlation was found between the K/T ratio and circulating IDO mass (r = 0.110) in serum. Urinary Kyn and Trp in the pediatric test cohort demonstrated elevations in the K/T ratio in symptomatic patients with UTI (median 13.08) and without UTI (median 14.38) compared to healthy controls (median 4.93; p < 0.001 for both comparisons). No significant difference in K/T ratio was noted between symptomatic patients with and without UTI (p = 0.84). Measurement of Trp and Kyn by LC-MS/MS is accurate and precise in serum and urine specimens. While urinary K/T ratio is not a specific biomarker for UTI, it may represent a general indicator of a systemic inflammatory process. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Measurement of the fragmentation fraction ratio $f_{s}/f_{d}$ and its dependence on $B$ meson kinematics

    CERN Document Server

    Aaij, R; Adametz, A; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves Jr, A A; Amato, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, Th; Bay, A; Beddow, J; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M -O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Corti, G; Couturier, B; Cowan, G A; Craik, D; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Del Buono, L; Deplano, C; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dickens, J; Dijkstra, H; Diniz Batista, P; Dogaru, M; Domingo Bonal, F; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Elsby, D; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Harrison, P F; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jans, E; Jansen, F; Jaton, P; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J -P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; von Loeben, J; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Luisier, J; Luo, H; Mac Raighne, A; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Mazurov, A; McCarthy, J; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M -N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nisar, S; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schleich, S; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, N A; Smith, E; Smith, M; Sobczak, K; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-01-01

    The relative production rate of $B^{0}_{s}$ and $B^{0}$ mesons is determined with the hadronic decays $B^{0}_{s} \\rightarrow D^{-}_{s}\\pi^{+}$ and $B^0 \\rightarrow D^{-}K^{+}$. The measurement uses data corresponding to 1.0 fb$^{-1}$ of $pp$ collisions at a centre-of-mass energy of $\\sqrt{s}=7$ TeV recorded in the forward region with the LHCb experiment. The ratio of production rates, $f_{s}/f_{d}$, is measured to be $0.238 \\pm 0.004 \\pm 0.015 \\pm 0.021 $, where the first uncertainty is statistical, the second systematic, and the third theoretical. This is combined with a previous LHCb measurement to obtain $f_{s}/f_{d} = 0.256 \\pm 0.020$. The dependence of $f_{s}/f_{d}$ on the transverse momentum and pseudorapidity of the $B$ meson is determined using the decays $B^{0}_{s} \\rightarrow D^{-}_{s}\\pi^{+}$ and $B^{0} \\rightarrow D^{-}\\pi^{+}$. There is evidence for a decrease with increasing transverse momentum, whereas the ratio remains constant as a function of pseudorapidity. In addition, the ratio of branchi...

  5. A new approach to estimate nuclide ratios from measurements with activities close to background

    International Nuclear Information System (INIS)

    Kirchner, G.; Steiner, M.; Zaehringer, M.

    2009-01-01

    Measurements of low-level radioactivity often give results of the order of the detection limit. For many applications, interest is not only in estimating activity concentrations of a single radioactive isotope, but focuses on multi-isotope analyses, which often enable inference on the source of the activity detected (e.g. from activity ratios). Obviously, such conclusions become questionable if the measurement merely gives a detection limit for a specific isotope. This is particularly relevant if the presence of an isotope, which shows a low signal only (e.g. due to a short half-life or a small transition probability), is crucial for gaining the information of interest. This paper discusses a new approach which has the potential to solve these problems. Using Bayesian statistics, a method is presented which allows statistical inference on nuclide ratios taking into account both prior knowledge and all information collected from the measurements. It is shown that our method allows quantitative conclusion to be drawn if counts of single isotopes are low or become even negative after background subtraction. Differences to the traditional statistical approach of specifying decision thresholds or detection limits are highlighted. Application of this new approach is illustrated by a number of examples of environmental low-level radioactivity measurements. The capabilities of our approach for spectrum interpretation and source identification are demonstrated with real spectra from air filters, sewage sludge and soil samples.

  6. Measurement of mercury isotopic ratio in stone meteorites by neutron activation analysis

    International Nuclear Information System (INIS)

    Thakur, A.N.

    1997-01-01

    196 Hg and 202 Hg isotopes have been measured by neutron activation analysis in samples of twelve stone meteorites. Hg is extracted from an irradiated sample by stepwise heating. The mercury concentrations vary from 0.07 to 33 ppm. While most of the samples give 196 Hg/ 202 Hg ratios similar to terrestrial value within error limits, in some cases large anomalies are observed. A number of control experiments have been devised, that show the absence of experimental artifacts, during sample preparation, neutron irradiation, chemical separation and counting stages. Several anomalous and normal Hg distillate have been re-irradiated as Hg-diethyl-dithio-carbamate complex to eliminate the influence of neutron self shielding and interfering reactions from matrix elements. The isotopic ratio patterns persist in the distillates too proving that any artifacts during meteorite irradiation and measurement are essentially absent. Both positive and negative anomalies are observed: however, the negative anomalies are much more frequent and abundant. In an extreme case of fine grained magnetic particles of Ambapur Nagla the 196 Hg is apparently absent in the Hg released at 100 deg C. A 2σ 196 Hg/ 202 Hg value is only 6% relative to the monitor. This experiment shows the robustness of neutron activation analysis and suggest some constrains on the formation history of stone meteorites. (author)

  7. Using hyperentanglement to enhance resolution, signal-to-noise ratio, and measurement time

    Science.gov (United States)

    Smith, James F.

    2017-03-01

    A hyperentanglement-based atmospheric imaging/detection system involving only a signal and an ancilla photon will be considered for optical and infrared frequencies. Only the signal photon will propagate in the atmosphere and its loss will be classical. The ancilla photon will remain within the sensor experiencing low loss. Closed form expressions for the wave function, normalization, density operator, reduced density operator, symmetrized logarithmic derivative, quantum Fisher information, quantum Cramer-Rao lower bound, coincidence probabilities, probability of detection, probability of false alarm, probability of error after M measurements, signal-to-noise ratio, quantum Chernoff bound, time-on-target expressions related to probability of error, and resolution will be provided. The effect of noise in every mode will be included as well as loss. The system will provide the basic design for an imaging/detection system functioning at optical or infrared frequencies that offers better than classical angular and range resolution. Optimization for enhanced resolution will be included. The signal-to-noise ratio will be increased by a factor equal to the number of modes employed during the hyperentanglement process. Likewise, the measurement time can be reduced by the same factor. The hyperentanglement generator will typically make use of entanglement in polarization, energy-time, orbital angular momentum and so on. Mathematical results will be provided describing the system's performance as a function of loss mechanisms and noise.

  8. A five-collector system for the simultaneous measurement of argon isotope ratios in a static mass spectrometer

    Science.gov (United States)

    Stacey, J.S.; Sherrill, N.D.; Dalrymple, G.B.; Lanphere, M.A.; Carpenter, N.V.

    1981-01-01

    A system is described that utilizes five separate Faraday-cup collector assemblies, aligned along the focal plane of a mass spectrometer, to collect simultaneous argon ion beams at masses 36-40. Each collector has its own electrometer amplifier and analog-to-digital measuring channel, the outputs of which are processed by a minicomputer that also controls the mass spectrometer. The mass spectrometer utilizes a 90?? sector magnetic analyzer with a radius of 23 cm, in which some degree of z-direction focussing is provided for all the ion beams by the fringe field of the magnet. Simultaneous measurement of the ion beams helps to eliminate mass-spectrometer memory as a significant source of measurement error during an analysis. Isotope ratios stabilize between 7 and 9 s after sample admission into the spectrometer, and thereafter changes in the measured ratios are linear, typically to within ??0.02%. Thus the multi-collector arrangement permits very short extrapolation times for computation of initial ratios, and also provides the advantages of simultaneous measurement of the ion currents in that errors due to variations in ion beam intensity are minimized. A complete analysis takes less than 10 min, so that sample throughput can be greatly enhanced. In this instrument, the factor limiting analytical precision now lies in short-term apparent variations in the interchannel calibration factors. ?? 1981.

  9. Prospects for measuring the branching ratio of the rare B0s→μ+μ- decay with the ATLAS experiment

    International Nuclear Information System (INIS)

    Sipica, Valentin

    2011-09-01

    The Large Hadron Collider (LHC) located at the CERN laboratory in Geneva provides p-p collisions at a centre-of-mass energy of √(s)=7 TeV. The study of the rare B 0 s →μ + μ - decay is among the research topics of ATLAS, one of the main experiments at the LHC. This decay is highly suppressed in the Standard Model of particle physics and may give an indirect evidence for New Physics models. This PhD thesis investigates prospects for measuring the branching ratio of the B 0 s →μ + μ - decay with the ATLAS experiment. The analysis is based on Monte Carlo data, with p-p collisions generated at a centre-of-mass energy of √(s)=10 TeV. The strategy employed is to calculate the B 0 s →μ + μ - branching ratio relative to the branching ratio of the B + → J/ψ(μ + μ - )K + decay. The dominant background channel is the b anti b→μ + μ - X combinatorial background. True B 0 s →μ + μ - decay candidates are separated from the much larger amount of combinatorial background events using several discriminating quantities. Upper limits on the B 0 s → μ + μ - branching ratio are computed using a Bayesian and a frequentist method. The expected precision of the branching ratio measurement is estimated for different values of the integrated luminosity. An expected upper limit on the branching ratio is computed to BR(B 0 s →μ + μ - ) -8 at a 95% confidence level for 1 fb -1 . The precision of the ATLAS measurement of the branching ratio will reach a level compatible with the best current measurements with about 2-5 fb -1 of data.

  10. Gating in time domain as a tool for improving the signal-to-noise ratio of beam transfer function measurements

    CERN Document Server

    Oeftiger, U; Caspers, Fritz

    1992-01-01

    For the measurement of Beam Transfer Functions the signal-to-noise ratio is of great importance. In order to get a reasonable quality of the measured data one may apply averaging and smoothing. In the following another technique called time gating to improve the quality of the measurement will be described. By this technique the measurement data are Fourier transformed and then modified in time domain. Tune gating suppresses signal contributions that are correlated to a time interval when no interesting information is expected. Afterivards an inverse Fourier transform leads to data in frequency domain with an improved signal to noise ratio.

  11. Fast centroid algorithm for determining the surface plasmon resonance angle using the fixed-boundary method

    International Nuclear Information System (INIS)

    Zhan, Shuyue; Wang, Xiaoping; Liu, Yuling

    2011-01-01

    To simplify the algorithm for determining the surface plasmon resonance (SPR) angle for special applications and development trends, a fast method for determining an SPR angle, called the fixed-boundary centroid algorithm, has been proposed. Two experiments were conducted to compare three centroid algorithms from the aspects of the operation time, sensitivity to shot noise, signal-to-noise ratio (SNR), resolution, and measurement range. Although the measurement range of this method was narrower, the other performance indices were all better than the other two centroid methods. This method has outstanding performance, high speed, good conformity, low error and a high SNR and resolution. It thus has the potential to be widely adopted

  12. White-tailed deer age ratios as herd management and predator impact measures in Pennsylvania

    Science.gov (United States)

    Rosenberry, Christopher S.; Norton, Andrew S.; Diefenbach, Duane R.; Fleegle, Jeannine T.; Wallingford, Bret D.

    2011-01-01

    A review of the Pennsylvania Game Commission's (PGC) deer management program and public concern about predator impacts on deer (Odocoileus virginianus) populations compelled the PGC to investigate the role of age ratios in developing management recommendations. Age ratios, such as proportion of juveniles in the antlerless harvest, may provide an index to population productivity and predator impacts. We estimated proportion of juveniles in the antlerless harvest from hunter-killed deer, population trends using the Pennsylvania (USA) sex–age–kill model, and reproduction from road-killed females. Using these estimates and a simulation model, we concluded that no single age-ratio value would serve as a reliable measure of population status. Wildlife Management Unit-specific trends in proportion of juveniles in the antlerless harvest and population trends provided the most relevant management information. We also provide an example decision chart to guide management actions in response to declining age ratios in the harvest. Although predator management activities and juvenile survival studies are often desired by the public, our decision-chart example indicated a number of deer management options exist before investing resources in predator management activities and juvenile survival studies.

  13. Acute evaluation of transthoracic impedance vectors using ICD leads.

    Science.gov (United States)

    Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils

    2009-06-01

    Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.

  14. Scan-rescan and intra-observer variability of magnetic resonance imaging of carotid atherosclerosis at 1.5 T and 3.0 T

    International Nuclear Information System (INIS)

    Vidal, Arvin; Wade, Trevor; Rutt, Brian K; Fenster, Aaron; Parraga, Grace; Bureau, Yves; Spence, J David

    2008-01-01

    Carotid atherosclerosis measurements for eight subjects at baseline and 14 ± 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five measurement trials. Mean increases in the signal-to-noise ratios (SNR) for T1-weighted images acquired at 3.0 T compared to 1.5 T were 90% (scan) and 80% (rescan). Despite significantly improved SNR and contrast-to-noise ratios (CNR) for images acquired at 3.0 T, vessel wall volume (VWV) intra-observer variability was not significantly different using coefficients of variation (COV), and intraclass correlation coefficients (ICC). VWV interscan variability and consistency at both field strengths were not statistically different (1.5 T/3.0 T COV = 5.7%/7.8%, R 2 = 0.96 for 1.5 T and R 2 = 0.87 for 3.0 T). A two-way analysis of variance showed a VWV dependence on field strength but not scan timepoint. In addition, a paired t-test showed significant differences in VWV measured at 3.0 T as compared to 1.5 T. These results suggest that although images acquired at 1.5 T have lower SNR and CNR VWV, measurement variability was not significantly different from 3.0 T VWV and that VWV is field-strength dependent which may be an important consideration for longitudinal studies.

  15. Scan-rescan and intra-observer variability of magnetic resonance imaging of carotid atherosclerosis at 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Arvin; Wade, Trevor; Rutt, Brian K; Fenster, Aaron; Parraga, Grace [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, N6A 5K8 (Canada); Bureau, Yves [Graduate Program in Biomedical Engineering, University of Western Ontario, London, N6A 5B9 (Canada); Spence, J David [Stroke Prevention and Atherosclerosis Research Centre, Robarts Research Institute, 1400 Western Road, London, N6A 5K8 (Canada)], E-mail: avidal@imaging.robarts.ca, E-mail: ybureau@lawsonimaging.ca, E-mail: twade@imaging.robarts.ca, E-mail: DSpence@robarts.ca, E-mail: brutt@imaging.robarts.ca, E-mail: afenster@imaging.robarts.ca, E-mail: gep@imaging.robarts.ca

    2008-12-07

    Carotid atherosclerosis measurements for eight subjects at baseline and 14 {+-} 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five measurement trials. Mean increases in the signal-to-noise ratios (SNR) for T1-weighted images acquired at 3.0 T compared to 1.5 T were 90% (scan) and 80% (rescan). Despite significantly improved SNR and contrast-to-noise ratios (CNR) for images acquired at 3.0 T, vessel wall volume (VWV) intra-observer variability was not significantly different using coefficients of variation (COV), and intraclass correlation coefficients (ICC). VWV interscan variability and consistency at both field strengths were not statistically different (1.5 T/3.0 T COV = 5.7%/7.8%, R{sup 2} = 0.96 for 1.5 T and R{sup 2} = 0.87 for 3.0 T). A two-way analysis of variance showed a VWV dependence on field strength but not scan timepoint. In addition, a paired t-test showed significant differences in VWV measured at 3.0 T as compared to 1.5 T. These results suggest that although images acquired at 1.5 T have lower SNR and CNR VWV, measurement variability was not significantly different from 3.0 T VWV and that VWV is field-strength dependent which may be an important consideration for longitudinal studies.

  16. An appraisal of subcooled boiling and slip ratio from measurements made in Lingen BWR

    International Nuclear Information System (INIS)

    Nash, G.

    1977-08-01

    Measurements of steam bubble velocities and voidage have been made in the relatively small Core B of Lingen BWR. The results of axial scanning in one radial position have produced experimental values of slip ratio, power (from a travelling incore probe), voidage and coolant mean density over the core height for this position. This one set of distributions has enabled us to test current UKAEA models of subcooled boiling and slip ratio against experiment. From the comparisons, it appears that we can predict the onset of voiding well, but the assumption that a constant fraction of the heat flux forms steam in the subcooled region needs modifying. Of four slip options tested, the current one used by HAMBO and JOSHUA III (Bankoff-Jones) predicts too high a slip ratio. A closer fit to experiment comes from the new Bryce flow-dependent slip option. Any changes in the modelling must be checked, however, with coupled thermal hydraulics-neutronics computations. (author)

  17. Criteria for designing an MRI quality assurance program. A multicenter trial

    International Nuclear Information System (INIS)

    Mascaro, L.; Baldassarri, A.M.

    1999-01-01

    The authors report the preliminary results of a multicenter trial aimed at defining methods, reference values and frequency of measurements for a magnetic resonance quality assurance program. In particular, they stress the definition of two attention levels (investigation and intervention) for image uniformity and signal-to-noise ratio (SNR) by means short-and long-term measurements [it

  18. Nuclear data and measurements series: Ratio of the prompt-fission-neutron spectrum of plutonium 239 to that of uranium 235

    International Nuclear Information System (INIS)

    Sugimoto, M.; Smith, A.B.; Guenther, P.T.

    1986-09-01

    The prompt-fission-neutron spectrum resulting from 239 Pu fission induced by 0.55 MeV incident neutrons is measured from 1.0 to 10.0 MeV relative to that of 235 U fission induced by the same incident-energy neutrons. The measurements employ the time-of-flight technique. Energy-dependent ratios of the two spectra are deduced from the measured values over the energy range 1.0 to 10.0 MeV. The experimentally-derived ratio results are compared with those calculated from ENDF/B-V, revision-2, and with results of recent microscopic measurements. Using the ENDF/B-V 235 U Watt parameters for the 235 U spectrum, the experimental measurements imply a ratio of average fission-spectrum energies of 239 Pu/ 235 U = 1.045 +- 0.003, compared to the value 1.046 calculated from ENDF/B-V, revision 2. 12 refs., 2 figs., 2 tabs

  19. WormGender - Open-Source Software for Automatic Caenorhabditis elegans Sex Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Marta K Labocha

    Full Text Available Fast and quantitative analysis of animal phenotypes is one of the major challenges of current biology. Here we report the WormGender open-source software, which is designed for accurate quantification of sex ratio in Caenorhabditis elegans. The software functions include, i automatic recognition and counting of adult hermaphrodites and males, ii a manual inspection feature that enables manual correction of errors, and iii flexibility to use new training images to optimize the software for different imaging conditions. We evaluated the performance of our software by comparing manual and automated assessment of sex ratio. Our data showed that the WormGender software provided overall accurate sex ratio measurements. We further demonstrated the usage of WormGender by quantifying the high incidence of male (him phenotype in 27 mutant strains. Mutants of nine genes (brc-1, C30G12.6, cep-1, coh-3, him-3, him-5, him-8, skr-1, unc-86 showed significant him phenotype. The WormGender is written in Java and can be installed and run on both Windows and Mac platforms. The source code is freely available together with a user manual and sample data at http://www.QuantWorm.org/. The source code and sample data are also available at http://dx.doi.org/10.6084/m9.figshare.1541248.

  20. On the performance of arbitrary transmit selection for threshold-based receive MRC with and without co-channel interference

    KAUST Repository

    Radaydeh, Redha Mahmoud Mesleh

    2011-11-01

    The performance of multiple-antenna diversity systems in which the receiver combines signal replicas per threshold-based maximal ratio combining (MRC) and transmitter uses only a single antenna according to receive combined signal strength is studied. The impact of imperfect channel estimation and the effect of phase and time misalignments between desired and undesired signals are implicitly investigated. It is assumed that the desired signal replicas and interfering signals undergo statistically independent flat Rayleigh fading. The analysis is applicable for arbitrary transmit antenna selection, based either on receive combined signal-to-noise ratio (SNR) or receive combined signal-to-interference-plus-noise ratio (SINR). For the scenario of identical multiple-antenna channels, closed-form analytical results for the combined SNR statistics and some performance measures are first presented. The SNR-based and SINR-based selection algorithms are then employed to obtain expressions for the distribution of combined SINR and outage probability performance, which are applicable for different statistical models of interfering signals. The adopted system models herein as well as the analytical development add enhancements on many existing results, and can be used to study the performance of different architectures under various channel conditions when the implementation complexity is of interest. © 2011 IEEE.