WorldWideScience

Sample records for rate instruments contained

  1. A summary of the performance of exposure rate and dose rate instruments contained in instrument evaluation reports NRPB-IE1 to NRPB-IE13

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report provides a concise summary of measurements of the more important performance characteristics of radiation protection dose rate or exposure rate survey instruments which have been assessed by NRPB as part

  2. Instrumentation of a prestressed concrete containment vessel model

    International Nuclear Information System (INIS)

    Hessheimer, M.F.; Rightley, M.J.; Matsumoto, T.

    1995-01-01

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the U.S. Nuclear Regulatory Commission. At present, two tests are being planned: a test of a model of a steel containment vessel (SCV) that is representative of an improved, boiling water reactor (BWR) Mark II design; and a test of a model of a prestressed concrete containment vessel (PCCV). This paper discusses plans and the results of a preliminary investigation of the instrumentation of the PCCV model. The instrumentation suite for this model will consist of approximately 2000 channels of data to record displacements, strains in the reinforcing steel, prestressing tendons, concrete, steel liner and liner anchors, as well as pressure and temperature. The instrumentation is being designed to monitor the response of the model during prestressing operations, during Structural Integrity and Integrated Leak Rate testing, and during test to failure of the model. Particular emphasis has been placed on instrumentation of the prestressing system in order to understand the behavior of the prestressing strands at design and beyond design pressure levels. Current plans are to place load cells at both ends of one third of the tendons in addition to placing strain measurement devices along the length of selected tendons. Strain measurements will be made using conventional bonded foil resistance gages and a wire resistance gage, known as a open-quotes Tensmegclose quotes reg-sign gage, specifically designed for use with seven-wire strand. The results of preliminary tests of both types of gages, in the laboratory and in a simulated model configuration, are reported and plans for instrumentation of the model are discussed

  3. Final Report: Part 1. In-Place Filter Testing Instrument for Nuclear Material Containers. Part 2. Canister Filter Test Standards for Aerosol Capture Rates.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Austin Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Runnels, Joel T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Moore, Murray E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reeves, Kirk Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-11-02

    ) fouling of o-rings, (B) leakage through simulated cracks in o-rings, and (C) air leakage due to inadequately tightened canister lids. The Los Alamos POC instrument determined pertinent air flow and pressure quantities, and this knowledge was used to specify a customized Isaac® (Z axis, Salt Lake City, UT) leak test module. The final Los Alamos IPFT (incorporating the Isaac® leak test module) was used to repeat the tests in the Instrument Development Plan (with simulated filter clogging tests and canister leak pathway tests). The Los Alamos IPFT instrument is capable of determining filter clogging and leak rate conditions, without requiring removal of the container lid. The IPFT measures pressure decay rate from 1.7E-03 in WC/sec to 1.7E-01 in WC/sec. On the same unit scale, helium leak testing of canisters has a range from 5.7E-07 in WC/sec to 1.9E-03 in WC/sec. For a 5-quart storage canister, the IPFT measures equivalent leak flow rates from 0.03 to 3.0 cc/sec. The IPFT does not provide the same sensitivity as helium leak testing, but is able to gauge the assembled condition of as-found and in-situ canisters.

  4. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  5. Virtual instrumentation: a new approach for control and instrumentation - application in containment studies facility

    International Nuclear Information System (INIS)

    Gole, N.V.; Shanware, V.M.; Sebastian, A.; Subramaniam, K.

    2001-01-01

    PC based data-acquisition has emerged as a rapidly developing area particularly with respect to process instrumentation. Computer based data acquisition in process instrumentation combined with Supervisory Control and Data Acquisition (SCADA) software has introduced extensive possibilities with respect to formats for presentation of information. The concept of presenting data using any instrument format with the help of software tools to simulate the instrument on screen, needs to be understood, in order to be able to make use of its vast potential. The purpose of this paper is to present the significant features of the Virtual Instrumentation concept and discuss its application in the instrumentation and control system of containment studies facility (CSF). Factors involved in the development of the virtual instrumentation based I and C system for CSF are detailed and a functional overview of the system configuration is given. (author)

  6. Instrument evaluation no. 9. Mini-instruments dose rate meter type 5 - 1OR

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered dose rate meter covering the dose rate range from 0 to 200 mrad h -1 . The instrument is designed to measure X- and γ-radiation dose rates over the energy range from 45 keV to 3 MeV. The radiation detector of the instrument is a GM tube with a specially designed energy compensation sheath. This detector is incorporated in a probe connected to the rate meter by an extensible cable which may be either hand-held or clipped on to the top of the instrument case. All the measurements in this report have been taken with the long axis of the probe normal to the direction of the incident radiation, the orientation recommended by the manufacturer. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; effect of ambient temperature; mechanical characteristics; summary of performance; conclusions. (U.K.)

  7. Instrumentation and testing of a prestressed concrete containment vessel model

    International Nuclear Information System (INIS)

    Hessheimer, M.F.; Pace, D.W.; Klamerus, E.W.

    1997-01-01

    Static overpressurization tests of two scale models of nuclear containment structures - a steel containment vessel (SCV) representative of an improved, boiling water reactor (BWR) Mark II design and a prestressed concrete containment vessel (PCCV) for pressurized water reactors (PWR) - are being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the U.S. Nuclear Regulatory Commission. This paper discusses plans for instrumentation and testing of the PCCV model. 6 refs., 2 figs., 2 tabs

  8. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  9. Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A. [New York Power Authority, White Plains, NY (United States)

    2013-01-31

    In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI's rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

  10. Neutron dose rate in the upper part of a PWR containment. Comparison between measurements and TRIPOLI-2 calculations

    International Nuclear Information System (INIS)

    Vergnaud, T.; Bourdet, L.; Gonnord, J.; Nimal, J.C.; Champion, G.

    1984-01-01

    Conception of a reactor building requires large openings in the primary concrete shield for a postulated loss-of-coolant accident. Through these openings neutrons escape and produce dose rates in several parts of the reactor building. Some calculations using ANISN, DOT and essentially TRIPOLI-2 codes allow to compute the neutron dose rates at several places such as reactor containment operating floor and containment annulus. Some complementary shields are provided and the instrumentations are placed in area where the dose rate is lower. Comparisons are presented between measurements and calculations

  11. Instrumented measurements on radioactive waste disposal containers during experimental drop testing - 59142

    International Nuclear Information System (INIS)

    Quercetti, Thomas; Musolff, Andre; Mueller, Karsten

    2012-01-01

    In context with disposal container safety assessment of containers for radioactive waste the German Federal Institute for Materials Research and Testing (BAM) performed numerous drop tests in the last years. The tests were accompanied by extensive and various measurement techniques especially by instrumented measurements with strain gages and accelerometers. The instrumentation of a specimen is an important tool to evaluate its mechanical behavior during impact. Test results as deceleration-time and strain-time functions constitute a main basis for the validation of assumptions in the safety analysis and for the evaluation of calculations based on finite-element methods. Strain gauges are useful to determine the time dependent magnitude of any deformation and the associated stresses. Accelerometers are widely used for the measuring of motion i.e. speed or the displacement of the rigid cask body, vibration and shock events. In addition high-speed video technique can be used to visualize and analyze the kinematical impact scenario by motion analysis. The paper describes some selected aspects on instrumented measurements and motion analysis in context with low level radioactive waste (LLW) container drop testing. (authors)

  12. The retributive rates, economic instrument, effective for the water decontamination in the Oriente Antioqueno

    International Nuclear Information System (INIS)

    Castro Hernandez, Luis Fernando

    1999-01-01

    The article contains the antecedents of the collection of the recompensing rates in Colombia at the beginning of the decade of the eighty it not insinuates as a mechanism for the atmospheric contamination. Later on the law 99 of 1993 defines it as the most important mechanism to not achieve the contamination of sources of water in the country. It establishes this way it the ordinance 901 of April of 1997 by means of which the process of implementation of the recompensing rates begins in the Oriente Antioqueno where at the moment is carried out the collection in eight basins. The article also registers the results that leave the economic instrument in what refers at levels of non-contamination of basins and in money collected after having billed five semesters. Likewise it reports a series of benefits that leaves the instrument after two years of implementation in the Oriente Antioqueno

  13. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  14. A rating instrument for fear of hospitalisation.

    Science.gov (United States)

    Jankovic, Slobodan M; Antonijevic, Gordana V; Vasic, Ivana R; Zivkovic-Radojevic, Marija N; Mirkovic, Snjezana N; Nikolic, Bosko V; Opancina, Valentina D; Putnik, Srdjan S; Radoicic, Ljiljana R; Raspopovic, Katarina M; Stanojevic, Dragan R; Teofilov, Sladjana D; Tomasevic, Katarina V; Radonjic, Vesela

    2018-04-01

    To develop and validate a reliable instrument that can measure fear of hospitalisation experienced by outpatients. After having a diagnosis established, some patients experience sense of fear, unpleasantness and embarrassment due to the possibility to be admitted to a hospital. Currently, there is no available instrument for measuring fear of hospitalisation. Cross-sectional study for assessing reliability and validity of a questionnaire. The questionnaire with 17 items and answers according to the Likert scale was developed during two brainstorming sessions of the research team. Its reliability, validity and temporal stability were tested on the sample of 330 outpatients. The study was multicentric, involving patients from seven cities and three countries. Fear of hospitalisation scale showed satisfactory reliability, when rated both by the investigators (Cronbach's alpha .799) and by the patients themselves (Cronbach's alpha .760). It is temporally stable, and both divergent and convergent validity tests had good results. Factorial analysis revealed three domains: fear of being injured, trust to medical staff and fear of losing privacy or autonomy. This study developed new reliable and valid instrument for measuring fear of hospitalisation. Identification of patients with high level of fear of hospitalisation by this instrument should help clinicians to administer measures which may decrease fear and prevent avoidance of healthcare utilisation. © 2018 John Wiley & Sons Ltd.

  15. Instrument evaluation no. 1. Nuclear Enterprises dose rate meter type NE 2602

    International Nuclear Information System (INIS)

    White, D.F.

    1974-01-01

    The NE2602 is a portable, battery-operated instrument for the measurement of exposure rates from 0.1 mR/h to 200 mR/h. The detector is an internally mounted Geiger-Muller tube provided with a correcting filter to minimise the variation of response with radiation energy. The instrument was specifically designed for the measurement of exposure rates from packages intended for transport. The detector is therefore mounted very close to the front surface of the instrument. The information is given under the following headings: facilities and controls; radiation performance; electrical characteristics; summary of performance; calibration procedure; construction; conclusions. (U.K.)

  16. Instrumentation availability during severe accidents for a boiling water reactor with a Mark I containment

    International Nuclear Information System (INIS)

    Arcieri, W.C.; Hanson, D.J.

    1992-02-01

    In support of the US Nuclear Regulatory Commission Accident Management Research Program, the availability of instruments to supply accident management information during a broad range of severe accidents is evaluated for a Boiling Water Reactor with a Mark I containment. Results from this evaluation include: (1) the identification of plant conditions that would impact instrument performance and information needs during severe accidents; (2) the definition of envelopes of parameters that would be important in assessing the performance of plant instrumentation for a broad range of severe accident sequences; and (3) assessment of the availability of plant instrumentation during severe accidents

  17. The Effectiveness of Learning Instruments of Speaking Containing Character Values toward Speaking Learning

    Directory of Open Access Journals (Sweden)

    Wisudariani N. M. R.

    2018-01-01

    Full Text Available This development research aimed at describing the effectiveness of learning instruments of speaking that were contained in character values. The objects of the study were a syllabus, lesson plan, textbook, and assessment. The subjects of the study were the lecturers of Speaking and the 2nd-semester students of IIA, IIB, and IIC in the academic year of 2015/2016. The data was collected through observation, questionnaire, and test. The data was analyzed by administering descriptive qualitative technique and descriptive statistics. The results of the study showed that the learning instruments was effective to be used in the teaching and learning process, to improve students understanding on the materials, to improve students speaking skill, and to shape characters such as religious, polite, communicative, open, democratic, respectful, responsible, curious, discipline, confident, cooperative, appreciate achievement, logic, critic, creative and innovative, and love reading. The results of the study indicated that the learning instruments of speaking contained of character values were effective so that it was feasible to be used by both lecturers and students of Indonesian Language and Literature Department, Language and Art Faculty of Ganesha University of Education.

  18. Instrumentation availability for a pressurized water reactor with a large dry containment during severe accidents

    International Nuclear Information System (INIS)

    Arcieri, W.C.; Hanson, D.J.

    1991-03-01

    In support of the US Nuclear Regulatory Commission (NRC) Accident Management Research Program, the availability of instruments to supply accident management information during a broad range of severe accidents is evaluated for a pressurized water reactor with a large dry containment. Results from this evaluation include the following: (a) identification of plant conditions that would impact instrument performance and information needs during severe accidents, (b) definition of envelopes of parameters that would be important in assessing the performance of plant instrumentation for a broad range of severe accident sequences, and (c) assessment of the availability of plant instrumentation during severe accidents. 16 refs., 3 figs., 4 tabs

  19. Instrument evaluation no. 8. Nuclear Enterprises beta/gamma dose rate meter type 0500

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered survey meter covering the dose rate range from 0 to 10,000 mrad h -1 and the dose range 0 to 1000 mrad. The instrument was designed to measure X and γ-radiation dose and dose rate over a wide energy range, and also β-radiation dose and dose rate. An unsealed ionisation chamber is used as the detector. The aluminised melinex thin end window of the chamber is provided with a detachable plastic end cap. The calibration plane of the chamber is indicated by a cross on the side of the instrument. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; conclusions. (U.K.)

  20. Aethalometer™ Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacek, Arthur J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-04-01

    The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

  1. Containment Leakage Rate Testing Program in NPP Krsko

    International Nuclear Information System (INIS)

    Dudas, M.; Heruc, Z.

    2002-01-01

    NPP Krsko adopted new regulations for testing of the reactor building containment as stipulated by 10CFR50 (Code of Federal Regulation) Appendix J, Option B instead of the previous requirement 10CFR50 Appendix J now renamed to 10CFR50 Appendix J, Option A. In the USA a thorough analyses of nuclear power plants reactor building containment testing was conducted. As part of these analyses the test results obtained from testing of various reactor-building containments in the last ten years were reviewed. It was concluded that it would be meaningful to, based on test results historical data, reconsider possibility of redefining testing intervals. The official proposal of such approach was reviewed and approved by the NRC and published in September of 1995 in the FR Vol.60 No.186. Based on directions from 10CFR50 Appendix J, Option B, the new criteria for definition of test intervals were created. Criteria were based upon past performance during testing (Performance-based Requirements) and safety impact. At NPP Krsko, the analyses of the Reactor Building Containment. Integrity Test results was performed . This included test results of the Containment Integrated Leak Rate Testing (CILRT or Type A tests), Containment Isolation Valves Local Leak Rater Tests (Type C tests) and Mechanical and Electrical Penetrations Local Leak Rate tests (Type B tests). In accordance with instructions from NEI 94-01 and based on analyses of test results, NPP Krsko created Containment Leakage Rate Testing Program with the purpose to establish the performance-based definition of test intervals, inspection scope, trending and reporting. Equally, the program gives instructions how to evaluate test results and how to deal with the containment penetration or isolation valve repair contingency. All changes caused with transition from Option A to Option B are marginal to public safety. (author)

  2. Influence of Loading Rate on the Calibration of Instrumented Charpy Strikers

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.; McColskey, D.; McCowan, C.

    2009-01-15

    One of the key factors for obtaining reliable instrumented Charpy results is the calibration of the instrumented striker. The conventional approach for establishing an analytical relationship between strain gage output and force applied to the transducer is the static calibration, which is preferably performed with the striker installed in the pendulum assembly. However, the response of an instrumented striker under static force application may sometimes differ significantly from its dynamic performance during an actual Charpy test. This is typically reflected in a large difference between absorbed energy returned by the pendulum encoder (KV) and calculated under the instrumented force/displacement test record (Wt). Such difference can be either minimized by optimizing the striker design or analytically removed by adjusting forces and displacements until KV = Wt (the so-called 'Dynamic Force Adjustment'). This study investigates the influence of increasing force application rates on the force/voltage characteristics of two instrumented strikers, one at NIST in Boulder, CO and one at SCK-CEN in Mol, Belgium.

  3. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  4. The influence of data collection rate, containment size and data smoothing on containment Integrated Leak Rate Tests

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.E.; Lurie, D.

    1988-01-01

    Phase I of a U.S. Nuclear Regulatory Commission contract investigated nuclear power plant Integrated Leak Rate Tests (ILRTs) using data gathered at many domestic and foreign ILRTs. The study evaluated ILRTs with the ANS criteria (in ANSI/ANS-56.8-1987) and the proposed extended ANS criteria (in draft Regulatory Guide, Task MS 021-5, October 1986). The study considered (1) the effects of data collection rates on ILRT conclusions, (2) a possible relationship between containment size, data collection rate and ILRT duration, (3) the impact of the proposed extended ANS methodology on ILRTs, and (4) the influence of data smoothing on ILRT data. The study was performed using 20 sets of Type A and 17 sets of verification data

  5. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  6. Analytical methods of leakage rate estimation from a containment under a LOCA

    International Nuclear Information System (INIS)

    Chun, M.H.

    1981-01-01

    Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from then mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than the mass leakage rate formula of CONTEMPT-LT. (author)

  7. Detecting The Expected Rate of Return Volatility of Financing Instruments of Indonesian Islamic Banking through GARCH Modeling (Generalized Autoregressive Conditional Heteroscedasticity

    Directory of Open Access Journals (Sweden)

    Nurul Huda

    2015-04-01

    Full Text Available Objective - Islamic banks are banks which its activities, both fund raising and funds distribution are on the basis of Islamic principles, namely buying and selling and profit sharing. Islamic banking is aimed at supporting the implementation of national development in order to improve justice, togetherness, and equitable distribution of welfare. In pursuit of supporting the implementation of national development, Islamic banking often faced stability problems of financing instruments being operated. In this case, it is measured by the gap between the actual rate of return and the expected rate of return. The individual actual RoR of this instrument will generate an expected rate of return. This raises the gap or difference between the actual rate of return and the expected rate of return of individual instruments, which in this case is called the abnormal rate of return. The stability of abnormal rate of return of individual instruments is certainly influenced by the stability of the expected rate of return. Expected rate of return has a volatility or fluctuation levels for each financing instrument. It is also a key element or material basis for the establishment of a variance of individual instruments. Variance in this case indicates the level of uncertainty of the rate of return. Individual variance is the origin of the instrument base for variance in the portfolio finance that further a portfolio analysis. So, this paper is going to analyze the level of expected RoR volatility as an initial step to see and predict the stability of the fluctuations in the rate of return of Indonesian Islamic financing instruments.Methods – Probability of Occurence, Expected Rate of Return (RoR and GARCH (Generalized Autoregressive Conditional Heteroscedasticity.Results - The expected RoR volatility of the murabaha and istishna financing instruments tend to be more volatile than expected RoR volatility of musharaka and qardh financing instruments

  8. A model to predict evaporation rates in habitats used by container-dwelling mosquitoes.

    Science.gov (United States)

    Bartlett-Healy, Kristen; Healy, Sean P; Hamilton, George C

    2011-05-01

    Container-dwelling mosquitoes use a wide variety of container habitats. The bottle cap is often cited as the smallest container habitat used by container species. When containers are small, the habitat conditions can greatly affect evaporation rates that in turn can affect the species dynamics within the container. An evaporation rate model was adapted to predict evaporation rates in mosquito container habitats. In both the laboratory and field, our model was able to predict actual evaporation rates. Examples of how the model may be applied are provided by examining the likelihood of Aedes albopictus (Skuse), Aedes aegypti (L.), and Culex pipiens pipiens (L.) completing their development within small-volume containers under typical environmental conditions and a range of temperatures. Our model suggests that under minimal direct sunlight exposure, both Ae. aegypti and Ae. albopictus could develop within a bottle cap before complete evaporation. Our model shows that under the environmental conditions when a plastic field container was sampled, neither Ae. albopictus or Cx. p. pipiens could complete development in that particular container before the water evaporated. Although rainfall could replenish the habitat, the effects of evaporation would increase larval density, which could in turn further decrease developmental rates.

  9. Development of a portable instrument to measure ozone production rates in the troposphere

    Science.gov (United States)

    Sklaveniti, Sofia; Locoge, Nadine; Stevens, Philip; Kumar, Vinod; Sinha, Vinayak; Dusanter, Sébastien

    2015-04-01

    Ground-level ozone is a key species related to air pollution, causing respiratory problems, damaging crops and forests, and affecting the climate. Our current understanding of the tropospheric ozone-forming chemistry indicates that net ozone production occurs via reactions of peroxy radicals (HO2 + RO2) with NO producing NO2, whose photolysis leads to O3 formation. Production rates of tropospheric ozone, P(O3), depend on concentrations of oxides of nitrogen (NOx = NO + NO2) and Volatile Organic Compounds (V OCs), but also on production rates of ROx radicals (OH + HO2 + RO2). The formation of ozone follows a complex nonlinear chemistry that makes strategies for reducing ozone difficult to implement. In this context, atmospheric chemistry models are used to develop emission regulations, but there are still uncertainties associated with the chemical mechanisms used in these models. Testing the ozone formation chemistry in atmospheric models is needed, in order to ensure the development of effective strategies for ozone reduction. We will present the development of an instrument for direct measurements of ozone production rates (OPR) in ambient air. The OPR instrument is made of three components: (i) two quartz flow tubes to sample ambient air, one exposed to solar radiation and one covered by a UV filter, (ii) a NO2-to-O3 conversion unit, and (iii) an ozone analyzer. The total amount of ozone exiting each flow tube is conserved in the form of Ox = NO2 + O3. Ozone production rates P(O3) are derived from the difference in Ox concentration between the two flow tubes, divided by the exposure time of air inside the flow tubes. We will present studies that were carried out in the laboratory to characterize each part of the instrument and we will discuss the performances of the OPR instrument based on experiments carried out using synthetic air mixtures of known composition (NOx and V OCs). Chemical modeling will also be presented to assess the reliability of ozone

  10. Evaporation rate in containers used for storing radioactive tracer solutions

    International Nuclear Information System (INIS)

    Gascon, J.L.

    2002-01-01

    In radiochemical analysis, the storage of a tracer solution is an important issue to bear in mind. The evaporation of the tracer solution depends on the type of container used for storing. Evaporation rate in four kinds of containers, i.e., flame-sealed glass ampoule, sealed glass flask, flame-sealed polyethylene ampoule and screw glass vial was studied. It is concluded that the evaporation rate depends on the system of closing. (author)

  11. Rating counselor-client behavior in online counseling: development and preliminary psychometric properties of the Counseling Progress and Depth Rating Instrument.

    Science.gov (United States)

    Bagraith, Karl; Chardon, Lydia; King, Robert John

    2010-11-01

    Although there are widely accepted and utilized models and frameworks for nondirective counseling (NDC), there is little in the way of tools or instruments designed to assist in determining whether or not a specific episode of counseling is consistent with the stated model or framework. The Counseling Progress and Depth Rating Instrument (CPDRI) was developed to evaluate counselor integrity in the use of Egan's skilled helper model in online counseling. The instrument was found to have sound internal consistency, good interrater reliability, and good face and convergent validity. The CPDRI is, therefore, proposed as a useful tool to facilitate investigation of the degree to which counselors adhere to and apply a widely used approach to NDC.

  12. Designing container shipping network under changing demand and freight rates

    Directory of Open Access Journals (Sweden)

    C. Chen

    2010-03-01

    Full Text Available This paper focuses on the optimization of container shipping network and its operations under changing cargo demand and freight rates. The problem is formulated as a mixed integer non-linear programming problem (MINP with an objective of maximizing the average unit ship-slot profit at three stages using analytical methodology. The issues such as empty container repositioning, ship-slot allocating, ship sizing, and container configuration are simultaneously considered based on a series of the matrices of demand for a year. To solve the model, a bi-level genetic algorithm based method is proposed. Finally, numerical experiments are provided to illustrate the validity of the proposed model and algorithms. The obtained results show that the suggested model can provide a more realistic solution to the issues on the basis of changing demand and freight rates and arrange a more effective approach to the optimization of container shipping network structures and operations than does the model based on the average demand.

  13. Development of instrumentation systems for severe accidents. 4. New accident tolerant in-containment pressure transducer for containment pressure monitoring system

    International Nuclear Information System (INIS)

    Oba, Masato; Teruya, Kuniyuki; Yoshitsugu, Makoto; Ikeuchi, Takeshi

    2015-01-01

    The accident at Tokyo Electric Power Company's Fukushima Dai-ichi Nuclear Power Plant (TF-1 accident) caused severe situations and resulted in a difficulty in measuring important parameters for monitoring plant conditions. Therefore, we have studied the TF-1 accident to select the important parameters that should be monitored at the severe accident and are developing the Severe Accident Instrumentations and Monitoring Systems that could measure the parameters in severe accident conditions. Mitsubishi Heavy Industries, LTD (MHI) developed a new accident tolerant containment pressure monitoring system and demonstrated that the monitoring system could endure extremely harsh environmental conditions that envelop severe accident environmental conditions inside a containment such as maximum operating temperature of up to 300degC and total integrated dose (TID) of 1 MGy gamma. The new containment pressure monitoring system comprises of a strain gage type pressure transducer and a mineral insulated (MI) cable with ceramic connectors, which are located in the containment, and a strain measuring amplifier located outside the containment. Less thermal and radiation degradation is achieved because of minimizing use of organic materials for in-containment equipment such as the transducer and connectors. Several tests were performed to demonstrate the performance and capability of the in-containment equipment under severe accident environmental conditions and the major steps in this testing were run in the following test sequences: (1) the baseline functional tests (e.g., repeatability, non-linearity, hysteresis, and so on) under normal conditions, (2) accident radiation testing, (3) seismic testing, and (4) steam/temperature test exposed to simulated severe accident environmental conditions. The test results demonstrate that the new pressure transducer can endure the simulated severe accident conditions. (author)

  14. NEK containment integrated leak rate test at full pressure

    International Nuclear Information System (INIS)

    Skaler, F.; Planinc, V.; Gregoric, D.; Cicvaric, D.

    1999-01-01

    NPP Krsko is a Pressure Water Reactor (PWR) Plant which has four barriers to prevent release of radioactive fission products. These four barriers are following: Fuel itself, Fuel Clad, Reactor Coolant System and Containment Building. Containment is the last barrier which can prevent release of fission product when other barriers have been already broken. To find out the real condition of containment vessel and to prove its ability of withstanding increased parameters during accident we have to perform Containment Integrated Leak Rate Test at least three times in every ten years of operation. CILRT 1999 in NPP Krsko was completely performed following regulation of 10CFR50 App. J Option A and ANSI/ANS 56.8-1987. The main goal of CILRT is to prove that the leakage of containment pathways and wall structures are within limits prescribed in Technical Specifications by pressurization of containment building above peak accident pressure Pa and measuring the mass changes of air using Ideal Gas Law.(author)

  15. Leak rate test of containment personnel lock

    International Nuclear Information System (INIS)

    Julien, J.T.; Peters, S.W.

    1988-01-01

    As part of the US NRC Containment Integrity Program, a leak rate test was performed on a full size personnel airlock for a nuclear containment building. The airlock was subjected to conditions simulating severe accident conditions. The objective of the test was to characterize the performance of airlock door seals when subjected to conditions that exceeded design. The seals tested were a double dog-ear configuration and made from EPDM E603. The data obtained from this test will be used by SNL as a benchmark for development of analytical methods. In addition to leak rate information, strain, temperature, displacements, and pressure data were measured and recorded from over 330 transducers. The test lasted approximately 60 hours. Data were recorded at regular intervals and during heating, pressurization and depressurization. The inner airlock door and bulkhead were exposed to a maximum air temperature of 850 F and a maximum air pressure of 300 psig. The airlock was originally designed for 340 F and 60 psig. Two heating and pressurization cycles were planned; one to heat to 400 F and pressurize to 300 psig, and the second to heat to 800 F and pressurize to 300 psig. No significant leakage was recorded during these two cycles. A third cycle was added to the test program. The air temperature was increased to 850 F and held at this temperature for approximately 10 hours. The inner door seal failed quickly at a pressure of 150.5 psig. The maximum leak rate was 706 SCFM

  16. Civil Aircraft for the regular investigation of the atmosphere based on an instrumented container: The new CARIBIC system

    Directory of Open Access Journals (Sweden)

    C. A. M. Brenninkmeijer

    2007-09-01

    Full Text Available An airfreight container with automated instruments for measurement of atmospheric gases and trace compounds was operated on a monthly basis onboard a Boeing 767-300 ER of LTU International Airways during long-distance flights from 1997 to 2002 (CARIBIC, Civil Aircraft for Regular Investigation of the Atmosphere Based on an Instrument Container, http://www.caribic-atmospheric.com. Subsequently a more advanced system has been developed, using a larger capacity container with additional equipment and an improved inlet system. CARIBIC phase #2 was implemented on a new long-range aircraft type Airbus A340-600 of the Lufthansa German Airlines (Star Alliance in December 2004, creating a powerful flying observatory. The instrument package comprises detectors for the measurement of O3, total and gaseous H2O, NO and NOy, CO, CO2, O2, Hg, and number concentrations of sub-micrometer particles (>4 nm, >12 nm, and >18 nm diameter. Furthermore, an optical particle counter (OPC and a proton transfer mass spectrometer (PTR-MS are incorporated. Aerosol samples are collected for analysis of elemental composition and particle morphology after flight. Air samples are taken in glass containers for laboratory analyses of hydrocarbons, halocarbons and greenhouse gases (including isotopic composition of CO2 in several laboratories. Absorption tubes collect oxygenated volatile organic compounds. Three differential optical absorption spectrometers (DOAS with their telescopes mounted in the inlet system measure atmospheric trace gases such as BrO, HONO, and NO2. A video camera mounted in the inlet provides information about clouds along the flight track. The flying observatory, its equipment and examples of measurement results are reported.

  17. Long-term leach rates of glasses containing actual waste

    International Nuclear Information System (INIS)

    Wiley, J.R.; LeRoy, J.H.

    1979-01-01

    Leach rates of borosilicate glasses that contained actual Savannah River Plant waste were measured. Leaching was done by water and by buffer solutions of pH 4, 7, and 9. Leach rates were then determined from the amount of 137 Cs, 90 Sr, and Pu released into the leach solutions. The cumulative fractions leached were fit to a mathematical model that included leaching by diffusion and glass dissolution

  18. In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Steffen; Weigel, Robert; Koelpin, Alexander [Institute for Electronics Engineering, University of Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen (Germany); Dennerlein, Juergen; Janke, Iryna; Weber, Johannes [AREVA GmbH, Paul-Gossen-Str. 100, 91052 Erlangen (Germany)

    2015-07-01

    Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

  19. Long-term leach rates of glasses containing actual waste

    International Nuclear Information System (INIS)

    Wiley, J.R.; LeRoy, J.H.

    1979-01-01

    Leach rates of borosilicate glasses that contained actual Savannah River Plant waste were measured. Leaching was done by water and by buffer solutions of pH 4, 7, and 9. Leach rates were then determined from the amount of 137 Cs, 90 Sr, and plutonium released into the leach solutions. The cumulative fractions leached were fit to a mathematical model that included leaching by diffusion and glass dissolution. 5 figures, 3 tables

  20. The principle and data analysis of online monitoring system of containment leak rate

    International Nuclear Information System (INIS)

    Zhang Chunwei; Yang Yongdeng; Qiao Yu; Liang Bo

    2014-01-01

    The use of online monitoring system of containment leak rate (EPP) in Qinshan 2nd nuclear power plant is introduced. When the containment leak rate reaches the operational limit, the system will automatically alarm and inform the unit operator to take the necessary action. But it is found that the EPP will give a mendacious alarm of 'Containment leak rate abnormity' once in a while during use. The mendacious alarm has an effect on the normal operation of the unit. The reason of the mendacious alarm is analyzed. The data monitored by the EPP are relative hysteretic and the veracity of the flow of compressed air into the containment has a significant influence on the data monitored by the EPP. (authors)

  1. Defining freight rates as a contribution to the successful operation of container shipping companies

    Directory of Open Access Journals (Sweden)

    Renato Oblak

    2016-12-01

    Full Text Available The globalization of the world market and the flexibility of containerization to adjust to the constant changes in supply and demand of the international goods market, has led to a continuous increase in the portion of the container transport within the international maritime cargo transport. By the increase of the container transport level, the impact and importance of container freight rates have been growing, the variability of which directly reflects on the world economy. The aim of this paper is to analyze the efficiency of actual methods in establishing the container freight rates according to the problems which appear in the container shipping operation and refer to large differences in the weights of the actual transported cargo and the declared cargo in containers. The consequence of is lower freight rates and higher costs of the vessels exploitation, concerning the increase of the bunker oil consumption. The conducted research is based on actual data that have been collected and analyzed from particular container vessel liner services within period of 90 days and casting off from 16 container ports. The proposed measures could increase the level of usability of the transporting ships capacities and enable a more accurate and correct account of sea freight rates. The results of the research have shown that by increasing the control of accuracy of the cargo weight in containers and by improving the model of accounting, the freight rates can increase the incomes of shipping companies maintaining the same level of container traffic, which can have a direct influence on the efficiency of their successful operation.

  2. Regulatory instrument review: Aging management of LWR cables, containment and basemat, reactor coolant pumps, and motor-operated valves

    International Nuclear Information System (INIS)

    Werry, E.V.; Somasundaram, S.

    1995-09-01

    The results of Stage 2 of the Regulatory Instrument Review are presented in this volume. Selected regulatory instruments, such as the Code of Federal Regulations (CFR), US Nuclear Regulatory Commission (NRC), Regulatory Guides, and ASME Codes, were investigated to determine the extent to which these regulations apply aging management to selected safety-related components in nuclear power plants. The Regulatory Instrument Review was funded by the NRC under the Nuclear Plant Aging Research (NPAR) program. Stage 2 of the review focused on four safety-related structures and components; namely, cables, containment and basemat, reactor coolant pumps, and motor-operated valves. The review suggests that the primary-emphasis of the regulatory instruments was on the design, construction, start-up, and operation of a nuclear power plant, and that aging issues were primarily addressed after an aging-related problem was recognized. This Stage 2 review confirms the results of the prior review; (see Regulatory Instrument Review: Management of Aging of LWR Major Safety-Related Components NUREG/CR-5490. The observations indicate that the regulations generally address management of age-related degradation indirectly. Specific age-related degradation phenomena frequently are dealt with in bulletins and notices or through generic issues, letters, etc. The major recommendation of this report, therefore, is that the regulatory instruments should more directly and explicitly address the aging phenomenon and the management of the age-related degradation process

  3. Forecasting Container Shipping Freight Rates for the Far East-Northern Europe Trade Lane

    DEFF Research Database (Denmark)

    Munim, Ziaul Haque; Schramm, Hans-Joachim

    2016-01-01

    econometric and time series modelling have been rather limited. Therefore, in this paper, we discuss contemporary container freight rate dynamics in an attempt to forecast for the Far East to Northern Europe trade lane. Methodology-wise, we employ autoregressive integrated moving average (ARIMA) as well......This study introduces a state-of-the-art volatility forecasting method for container shipping freight rates. Over the last decade, the container shipping industry has become very unpredictable. The demolition of the shipping conferences system in 2008 for all trades calling a port in the European...

  4. Development of an instrument for direct ozone production rate measurements: measurement reliability and current limitations

    Science.gov (United States)

    Sklaveniti, Sofia; Locoge, Nadine; Stevens, Philip S.; Wood, Ezra; Kundu, Shuvashish; Dusanter, Sébastien

    2018-02-01

    Ground-level ozone (O3) is an important pollutant that affects both global climate change and regional air quality, with the latter linked to detrimental effects on both human health and ecosystems. Ozone is not directly emitted in the atmosphere but is formed from chemical reactions involving volatile organic compounds (VOCs), nitrogen oxides (NOx = NO + NO2) and sunlight. The photochemical nature of ozone makes the implementation of reduction strategies challenging and a good understanding of its formation chemistry is fundamental in order to develop efficient strategies of ozone reduction from mitigation measures of primary VOCs and NOx emissions. An instrument for direct measurements of ozone production rates (OPRs) was developed and deployed in the field as part of the IRRONIC (Indiana Radical, Reactivity and Ozone Production Intercomparison) field campaign. The OPR instrument is based on the principle of the previously published MOPS instrument (Measurement of Ozone Production Sensor) but using a different sampling design made of quartz flow tubes and a different Ox (O3 and NO2) conversion-detection scheme composed of an O3-to-NO2 conversion unit and a cavity attenuated phase shift spectroscopy (CAPS) NO2 monitor. Tests performed in the laboratory and in the field, together with model simulations of the radical chemistry occurring inside the flow tubes, were used to assess (i) the reliability of the measurement principle and (ii) potential biases associated with OPR measurements. This publication reports the first field measurements made using this instrument to illustrate its performance. The results showed that a photo-enhanced loss of ozone inside the sampling flow tubes disturbs the measurements. This issue needs to be solved to be able to perform accurate ambient measurements of ozone production rates with the instrument described in this study. However, an attempt was made to investigate the OPR sensitivity to NOx by adding NO inside the instrument

  5. Student Evaluation of Teaching: A Study Exploring Student Rating Instrument Free-Form Text Comments

    Science.gov (United States)

    Stupans, Ieva; McGuren, Therese; Babey, Anna Marie

    2016-01-01

    Student rating instruments are recognised to be valid indicators of effective instruction, providing a valuable tool to improve teaching. However, free-form text comments obtained from the open-ended question component of such surveys are only infrequently analysed comprehensively. We employed an innovative, systematic approach to the analysis of…

  6. Code of practice for in-core instrumentation for neutron fluence rate (flux) measurements in power reactors

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    This standard applies to in-core (on-line) neutron detectors and instrumentation which is designed for safety, information or control purposes. It also applies to components in so far as these components are contained within the primary envelope of the reactor. The detector types usually used are dc ionization chambers and self-powered neutron detectors

  7. Risk-free assets: Are they truly risk-free? A comparative study of South African rates and instruments

    Directory of Open Access Journals (Sweden)

    Oosthuizen, A.V.

    2013-10-01

    Full Text Available Determining the price of a financial instrument is something that happens every day in the financial markets. Every price starts off with a spot price adjusted for interest until maturity of the particular instrument. The interest is usually described as risk-free interest. The price so determined is the most basic price that an investor is willing to pay if not risk is involved. Risk-free assets, then, are securities of which the future rates of return are known with certainty. An exceptional degree of confidence in the issuer of the security brings about this certainty. Risk-free assets are normally in the fixed income securities (capital markets investment category or in the liquid money market instruments such as treasury bills, category. This study attempts to determine whether the risk-free rates used by treasury managers and traders in South Africa to formulate their bond yield curves and which are used in valuation models, may be deemed risk-free. The study specifies certain criteria that an asset must satisfy in order to be used as a risk-free asset. Short term and long term South African instruments are compared to the US counterpart instruments, to gain an understanding of the South African instruments relative to the US ones. The behaviour of the risk-free instruments used in South Africa is also compared to the FTSE/JSE All Share Index and gold spot prices, which are perceived to be a risky asset classes. To gain some understanding of the behaviour of these instruments, analyses were done from different angles. The standard deviations of the daily percentage changes of the R157 were significantly lower than that of the ALSI and the gold spot price change. Compared to the ALSI and gold spot price, therefore, the R157 may be deemed a “low risk” instrument. The JIBAR was even less volatile that the R157. Interestingly, the US instruments were substantially more risky than the SA instruments over the analysis period. Also the JIBAR

  8. Increased degradation rate of nitrososureas in media containing carbonate.

    Science.gov (United States)

    Seidegård, Janeric; Grönquist, Lena; Tuvesson, Helen; Gunnarsson, Per-Olov

    2009-01-01

    The stability of two nitrosoureas, tauromustine and lomustine, has been investigated in different media and buffers. All media tested, except Leibovitz's L-15 medium, significantly increased the degradation rate of the investigated nitrosoureas at pH 7.4. Sodium bicarbonate seems to be the cause of the observed increase of the degradation rate, since it provides the main buffering capacity of all the media except for Leibovitz's L-15 medium, which is based on phosphate buffer. Other ingredients in the media, such as amino acids, vitamins, and inorganic salts, or the ionic strength of a buffer, did not have any major effect on the degradation rate of the nitrosoureas. These results suggest that media containing carbonated buffer should be avoided when the anti-tumor effect of nitrosoureas is to be investigated in different cell cultures.

  9. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    Full text: The United States Customs Service has, as a part of its mission, the protection of the borders of the United States from the import or export of illicit radioactive materials. Of paramount importance is the ability to interdict the smuggling of special nuclear material, nuclear weapons and other radioactive materials that could be used as a weapon of mass destruction against the population and infrastructure of the U.S. or another country. Radiation detection technology exists in the form of pocket size, hand-held and portal radiation detectors that have the ability to detect radiation with great sensitivity and low false alarm rates. U.S. Customs has chosen to implement pocket size detectors or radiation pagers as the personal tool of each inspector for the detection of radioactive material. In the search for illicit shipment of radioactive materials, innocent radiation detections may occur with some frequency due to common radioactive sources that may be encountered in day to day living. Examples include lantern mantles, some camera lenses, welding rods, certain dishware containing uranium glaze, and natural marble objects such as statues or architectural pieces. Perhaps the most common innocent detection encountered at the border and in public areas in general is due to the in vivo placement of radioactive sources for use in nuclear medicine therapy and diagnostics. Outpatients from such therapy can remain detectable for three weeks or more. Also, legal shipments of radioisotopes are common occurrences in cargo and express mail shipments. The customs inspector who detects radioactive material in the course of his duties must decide whether detection is innocent; is indicative of a nuclear device or special nuclear material; or whether the source could be injurious to him/her or the general public. It is at this point that a portable instrument capable of identifying gamma or neutron emitting isotopes is essential to the customs examination procedure

  10. Leach rate studies on glass containing actual radioactive waste

    International Nuclear Information System (INIS)

    Walker, D.D.; Wiley, J.R.; Dukes, M.D.; LeRoy, J.H.

    1980-01-01

    Borosilicate glass containing radioactive wastes from the Savannah River Plant have been leached for 900 days. The International Standards Organization's (ISO) static leach test procedure was used on glass buttons in various leachants. Leach rates based on 90 Sr and 137 Cs analyses were similar: 2 x 10 -8 to 3 x 10 -8 g/(cm 2 )(d) in distilled water, 1 x 10 -8 to 3 x 10 -7 g/(cm 2 )(d) in pH 7 buffer, 3 x 10 -7 to 7 x 10 -7 g/(cm 2 )(d) in pH 9 buffer, and 7 x 10 -6 to 8 x 10 -5 g/(cm 2 )(d) in pH 4 buffer. Rates based on Pu analyses were the same as above in distilled water and pH 9 buffer, but were lower by an order of magnitude in pH 4 and pH 7 buffers. Almost all leach rates remained constant between 200 and 900 days of leaching. Increasing the concentration of the buffering agents had no effect on the leach rates at pH 7 (phosphate) and pH 9 (carbonate), but dramatically increased the rates at pH 4 (acetate). Leach rates did not differ significantly between high aluminum and high iron waste glasses

  11. Using An Adapter To Perform The Chalfant-Style Containment Vessel Periodic Maintenance Leak Rate Test

    International Nuclear Information System (INIS)

    Loftin, B.; Abramczyk, G.; Trapp, D.

    2011-01-01

    Recently the Packaging Technology and Pressurized Systems (PT and PS) organization at the Savannah River National Laboratory was asked to develop an adapter for performing the leak-rate test of a Chalfant-style containment vessel. The PT and PS organization collaborated with designers at the Department of Energy's Pantex Plant to develop the adapter currently in use for performing the leak-rate testing on the containment vessels. This paper will give the history of leak-rate testing of the Chalfant-style containment vessels, discuss the design concept for the adapter, give an overview of the design, and will present results of the testing done using the adapter.

  12. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  13. 26 CFR 1.1275-5 - Variable rate debt instruments.

    Science.gov (United States)

    2010-04-01

    ... nonpublicly traded property. A debt instrument (other than a tax-exempt obligation) that would otherwise... variations in the cost of newly borrowed funds in the currency in which the debt instrument is denominated... on the yield of actively traded personal property (within the meaning of section 1092(d)(1)). (ii...

  14. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  15. Natural radioactivity of bedrock bath instruments and hot spring instruments in Japan

    International Nuclear Information System (INIS)

    Kazuki Iwaoka; Hiroyuki Tabe; Hidenori Yonehara

    2013-01-01

    In Japan, bedrock bath instruments and hot spring instruments that contain natural radioactive nuclides are commercially available. In this study, such instruments containing natural radioactive nuclides, currently distributed in Japan, were collected and the radioactivity concentration of 238 U series, 232 Th series, and 40 K in them was determined by gamma ray spectrum analyses. Effective doses to workers and general consumers handling the materials were estimated, revealing the radioactivity concentration of 238 U series, 232 Th series, and 40 K to be lower than critical values given in the IAEA Safety Guide. The maximum effective doses to workers and general consumers were 210 and 6.1 μSv y -1 , respectively. These values are lower than the intervention exemption level (1,000 μSv y -1 ) given in ICRP Publ. 82. (author)

  16. Integrated leak rate testing of the fast flux test facility reactor containment building

    International Nuclear Information System (INIS)

    James, E.B.; Farabee, O.A.; Bliss, R.J.

    1978-01-01

    The initial Integrated Leak Rate Test (ILRT) of the Fast Flux Test Facility containment building was performed from May 27 to June 2, 1978. The test was conducted in air with systems vented and with the containment recirculating coolers in operation. 10 psig and 5 psig tests were run using the absolute pressure test method. The measured leakage rates were .033% Vol/24 hr. and -.0015% Vol/24 hrs. respectively. Subsequent verification tests at both 10 psig and 5 psig proved that the test equipment was operating properly and it was sensitive enough to detect leaks at low pressures. This ILRT was performed at a lower pressure than any previous ILRT on a reactor containment structure in the United States. While the initial design requirements for ice condenser containments called for a part pressure test at 6 psig, the tests were waived due to the apparent statistical problems of data analysis and the repeatability of the data itself at such low pressure. In contrast to this belief, both the 5 and 10 psig ILRT's were performed in a successful manner at FFTF

  17. Reliability of the Motor Learning Strategy Rating Instrument for Children and Youth with Acquired Brain Injury

    Science.gov (United States)

    Kamath, Trishna; Pfeifer, Megan; Banerjee-Guenette, Priyanka; Hunter, Theresa; Ito, Julia; Salbach, Nancy M.; Wright, Virginia; Levac, Danielle

    2012-01-01

    Purpose: To evaluate reliability and feasibility of the Motor Learning Strategy Rating Instrument (MLSRI) in children with acquired brain injury (ABI). The MLSRI quantifies the extent to which motor learning strategies (MLS) are used within physiotherapy (PT) interventions. Methods: PT sessions conducted by ABI team physiotherapists with a…

  18. Fabrication of internally instrumented reactor fuel rods

    International Nuclear Information System (INIS)

    Schmutz, J.D.; Meservey, R.H.

    1975-01-01

    Procedures are outlined for fabricating internally instrumented reactor fuel rods while maintaining the original quality assurance level of the rods. Instrumented fuel rods described contain fuel centerline thermocouples, ultrasonic thermometers, and pressure tubes for internal rod gas pressure measurements. Descriptions of the thermocouples and ultrasonic thermometers are also contained

  19. An instrument for measurement of 125I with automatic efficiency correction

    International Nuclear Information System (INIS)

    Holford, R.M.

    1979-10-01

    Counting efficiencies for 125 I are often uncertain because of self-absorption of the low-energy radiation. A special purpose instrument, AEP-5285, has been designed to simplify the measurement of 125 I activities using a known technique in which the observed counting rate is compensated for self-absorption and any other uncertainties in the counting efficiency by making use of the coicidence properties of the radiation. The instrument contains pulse amplifiers, discriminators to define the energy regions of interest, and operational amplifier circuits to perform the necessary calculations automatically, and it displays an estimate of the source activity in becquerels. (auth)

  20. Calcium release rates from tooth enamel treated with dentifrices containing whitening agents and abrasives.

    Science.gov (United States)

    Araujo, Danilo Barral; Silva, Luciana Rodrigues; de Araujo, Roberto Paulo Correia

    2010-01-01

    Tooth whitening agents containing hydrogen peroxide and carbamide peroxide are used frequently in esthetic dental procedures. However, lesions on the enamel surface have been attributed to the action of these products. Using conventional procedures for separating and isolating biological structures, powdered enamel was obtained and treated with hydrogen peroxide, carbamide peroxide, and sodium bicarbonate, ingredients typically found in dentifrices. The enamel was exposed to different pH levels, and atomic emission spectrometry was used to determine calcium release rates. As the pH level increased, the rate of calcium release from enamel treated with dentifrices containing whitening agents decreased. Carbamide peroxide produced the lowest amount of decalcification, while sodium bicarbonate produced the highest release rates at all pH levels.

  1. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1975-01-01

    A liquid metal cooled nuclear reactor is described which has an equal number of fuel sub-assemblies and sensing instruments. Each instrument senses temperature and rate of coolant flow of a coolant derived from a group of three sub-assemblies so that an abnormal value for one sub-assembly will be indicated on three instruments thereby providing for redundancy of up to two of the three instruments. The abnormal value may be a precurser to unstable boiling of coolant

  2. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  3. EDF reactor building containment: Monitoring of the pre-stressed concrete structure

    International Nuclear Information System (INIS)

    Badez, N.

    2009-01-01

    The concrete containments of the EDF PWR are pre-stressed, and are monitored to observe the ageing effects on the structure, in particular the evolutions of creep, shrinkage, pre-stress loss, and air leakage tightness. Monitoring devices are installed during construction period, and measurements are checked, stored on a data base, and analysed during all the plant operating life time. The topic of the presentation is to present each part of the EDF monitoring organisation. A continuous monitoring makes it possible to produce periodical comprehensive reports about the mechanical analysis of the structure, the strain stabilisation,... Periodical tests (each 10 years) are planned. They consist to submit the containment to an internal air pressure at the accidental pressure level. The monitoring system gives the strain values in order to check their linearity and reversibility with decreasing pressure. At the same time, the containment tightness is checked with a specific instrumentation to verify that leak rate is lower than the required level. A general view of instrumentation implemented on the containment (sensors, data acquisition), and a data analysis are presented

  4. Pre-operational proof and leakage rate testing requirements for concrete containment structures for CANDU nuclear power plants

    International Nuclear Information System (INIS)

    1994-02-01

    This Standard provides the requirements for pre-operational proof tests and leakage rate tests of concrete containment structures of a containment system designed as Class Containment components. 1 fig

  5. A dual-energy medical instrument for measurement of x-ray source voltage and dose rate

    Science.gov (United States)

    Ryzhikov, V. D.; Naydenov, S. V.; Volkov, V. G.; Opolonin, O. D.; Makhota, S.; Pochet, T.; Smith, C. F.

    2016-03-01

    An original dual-energy detector and medical instrument have been developed to measure the output voltages and dose rates of X-ray sources. Theoretical and experimental studies were carried out to characterize the parameters of a new scintillator-photodiode sandwich-detector based on specially-prepared zinc selenide crystals in which the low-energy detector (LED) works both as the detector of the low-energy radiation and as an absorption filter allowing the highenergy fraction of the radiation to pass through to the high-energy detector (HED). The use of the LED as a low-energy filter in combination with a separate HED opens broad possibilities for such sandwich structures. In particular, it becomes possible to analyze and process the sum, difference and ratio of signals coming from these detectors, ensuring a broad (up to 106) measurement range of X-ray intensity from the source and a leveling of the energy dependence. We have chosen an optimum design of the detector and the geometry of the component LED and HED parts that allow energy-dependence leveling to within specified limits. The deviation in energy dependence of the detector does not exceed about 5% in the energy range from 30 to 120 keV. The developed detector and instrument allow contactless measurement of the anode voltage of an X-ray emitter from 40 to 140 kV with an error no greater than 3%. The dose rate measurement range is from 1 to 200 R/min. An original medical instrument has passed clinical testing and was recommended for use in medical institutions for X-ray diagnostics.

  6. The Effect of Teaching Experience and Specialty (Vocal or Instrumental) on Vocal Health Ratings of Music Teachers

    Science.gov (United States)

    Hackworth, Rhonda S.

    2010-01-01

    The current study sought to determine the relationship among music teachers' length of teaching experience, specialty (vocal or instrumental), and ratings of behaviors and teaching activities related to vocal health. Participants (N = 379) were experienced (n = 208) and preservice (n = 171) music teachers, further categorized by specialty, either…

  7. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  8. Performance-based improvement of the leakage rate test program for the reactor containment of HTTR. Adoption of revised test programs containing 'Type A, Type B and Type C tests'

    International Nuclear Information System (INIS)

    Kondo, Masaaki; Emori, Koichi; Sekita, Kenji; Furusawa, Takayuki; Hayakawa, Masato; Kozawa, Takayuki; Aono, Tetsuya; Kuroha, Misao; Ouchi, Hiroshi; Kimishima, Satoru

    2008-10-01

    The reactor containment of HTTR is periodically tested to confirm leak-tight integrity by conducting overall integrated leakage rate tests, so-called 'Type A tests,' in accordance with a standard testing method provided in Japan Electric Association Code (JEAC) 4203. 'Type A test' is identified as a basic one for measuring whole leakage rates for reactor containments, it takes, however, much of cost and time of preparation, implementation and restoration of itself. Therefore, in order to upgrade the maintenance technology of HTTR, the containment leakage rate test program for HTTR was revised by adopting efficient and economical alternatives including Type B and Type C tests' which intend to measure leakage rates for containment penetrations and isolation valves, respectively. In JEAC4203-2004, following requirements are specified for adopting an alternative program: upward trend of the overall integrated leakage rate due to aging affection should not be recognized; performance criterion for combined leakage rate, that is a summation of local leakage rates evaluated by Type B and Type C tests and converted to whole leakage rates, should be established; the criterion of the combined leakage rate should be satisfied as well as of the overall integrated leakage rate; correlation between the overall integrated and combined leakage rates should be recognized. Considering the historical performances, policies of conforming to the forgoing requirements and of carrying out the revised test program were developed, which were accepted by the regulatory agency. This report presents an outline of the leakage rate tests for the reactor containment of HTTR, identifies practical issues of conventional Type A tests, and describes the conforming and implementing policies mentioned above. (author)

  9. Minimally invasive instrumentation without fusion during posterior thoracic corpectomies: a comparison of percutaneously instrumented nonfused segments with open instrumented fused segments.

    Science.gov (United States)

    Lau, Darryl; Chou, Dean

    2017-07-01

    OBJECTIVE During the mini-open posterior corpectomy, percutaneous instrumentation without fusion is performed above and below the corpectomy level. In this study, the authors' goal was to compare the perioperative and long-term implant failure rates of patients who underwent nonfused percutaneous instrumentation with those of patients who underwent traditional open instrumented fusion. METHODS Adult patients who underwent posterior thoracic corpectomies with cage reconstruction between 2009 and 2014 were identified. Patients who underwent mini-open corpectomy had percutaneous instrumentation without fusion, and patients who underwent open corpectomy had instrumented fusion above and below the corpectomy site. The authors compared perioperative outcomes and rates of implant failure requiring reoperation between the open (fused) and mini-open (unfused) groups. RESULTS A total of 75 patients were identified, and 53 patients (32 open and 21 mini-open) were available for followup. The mean patient age was 52.8 years, and 56.6% of patients were male. There were no significant differences in baseline variables between the 2 groups. The overall perioperative complication rate was 15.1%, and there was no significant difference between the open and mini-open groups (18.8% vs 9.5%; p = 0.359). The mean hospital stay was 10.5 days. The open group required a significantly longer stay than the mini-open group (12.8 vs 7.1 days; p open and mini-open groups at 6 months (3.1% vs 0.0%, p = 0.413), 1 year (10.7% vs 6.2%, p = 0.620), and 2 years (18.2% vs 8.3%, p = 0.438). The overall mean follow-up was 29.2 months. CONCLUSIONS These findings suggest that percutaneous instrumentation without fusion in mini-open transpedicular corpectomies offers similar implant failure and reoperation rates as open instrumented fusion as far out as 2 years of follow-up.

  10. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    Science.gov (United States)

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  11. Instrumentation for a radon research house

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Revzan, K.L.; Robb, A.W.

    1981-07-01

    A highly automated monitoring and control system for studying radon and radon-daughter behavior in residences has been designed and built. The system has been installed in a research house, a test space contained in a two-story wood-framed building, which allows us to conduct controlled studies of (1) pollutant transport within and between rooms, (2) the dynamics of radon daughter behavior, and (3) techniques for controlling radon and radon daughters. The system's instrumentation is capable of measuring air-exchange rate, four-point radon concentration, individual radon daughter concentrations, indoor temerature and humidity, and outdoor weather parameters (temperature, humidity, modules, wind speed, and wind direction). It is also equipped with modules that control the injection of radon and tracer gas into the test space, the operation of the forced-air furnace, the mechanical ventilation system, and the mixing fans located in each room. A microcomputer controls the experiments and records the data on magnetic tape and on a printing terminal. The data on tape is transferred to a larger computer system for reduction and analysis. In this paper we describe the essential design and function of the instrumentation system, as a whole, singling out those components that measure ventilation rate, radon concentration, and radon daughter concentrations

  12. Measurement of disintegration rates of small [60Co]Co sources in lead containers by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to determine the disintegration rates of two small [ 60 Co]Co sources (30 and 350 kBq) in lead containers with several thickness by using a NaI(Tl) detector. The experimental results showed that the sum-peak method was perfectly effective for the determination of the disintegration rates (unrelated to the thicknesses of the containers) of the 350 kBq source. The sum-peak method was also absolutely effective for the 30 kBq source in the case of containers with thicknesses of 15 mm and less, but in the cases of those with thicknesses of 21, 27 and 33 mm, the disintegration rates were under-estimated and the deviations from the true disintegration rate increased rapidly with increasing thicknesses of the containers. We presume that the under-estimation of the disintegration rates was the result of the over-estimation of the areas under the sum peaks, caused by the interference of the γ-ray (2614 keV) emitted from the naturally occurring radionuclide 208 Tl. (author)

  13. Estimates of Radiation Dose Rates Near Large Diameter Sludge Containers in T Plant

    CERN Document Server

    Himes, D A

    2002-01-01

    Dose rates in T Plant canyon during the handling and storage of large diameter storage containers of K Basin sludge were estimated. A number of different geometries were considered from which most operational situations of interest can be constructed.

  14. A Monte Carlo program to calculate the exposure rate from airborne radioactive gases inside a nuclear reactor containment building.

    Science.gov (United States)

    Sherbini, S; Tamasanis, D; Sykes, J; Porter, S W

    1986-12-01

    A program was developed to calculate the exposure rate resulting from airborne gases inside a reactor containment building. The calculations were performed at the location of a wall-mounted area radiation monitor. The program uses Monte Carlo techniques and accounts for both the direct and scattered components of the radiation field at the detector. The scattered component was found to contribute about 30% of the total exposure rate at 50 keV and dropped to about 7% at 2000 keV. The results of the calculations were normalized to unit activity per unit volume of air in the containment. This allows the exposure rate readings of the area monitor to be used to estimate the airborne activity in containment in the early phases of an accident. Such estimates, coupled with containment leak rates, provide a method to obtain a release rate for use in offsite dose projection calculations.

  15. An analytical means of comparing the rates of different agglomeration mechanisms, and its application to a PWR containment

    International Nuclear Information System (INIS)

    Payne, J.F.B.; Skyrme, G.

    1993-01-01

    In this paper, agglomeration behaviour is described analytically and this quantitative description is used as a means of comparing the rates of different agglomeration mechanisms. The comparison depends on the average particle size but does not require detailed knowledge of the particle size distribution. The method is applied to the agglomeration of an aerosol suspended in the atmosphere of a pressurized water reactor (PWR) containment building. The rate of turbulent agglomeration in the PWR containment depends upon the degree of turbulence at each point in the fluid, expressed as the turbulent energy dissipation rate, ε. An approximate model of the containment flow is solved to obtain a satisfactory estimate of the functions of ε needed in evaluating turbulent agglomeration rates. (Author)

  16. Radiolytic oxidation of iodine in the containment at high temperature and dose rate

    International Nuclear Information System (INIS)

    Guilbert, S.; Bosland, L.; Jacquemain, D.; Clement, B.; Andreo, F.; Ducros, G.; Dickinson, S.; Herranz, L.; Ball, J.

    2007-01-01

    Iodine Chemistry is one of the areas of top interest in the field of nuclear power plants (NPP) severe accidents studies. The strong radiological impact of iodine on man health and environment, mostly through its isotope I-131, has made it a key point to get an accurate prediction of the potential iodine release from the NPP containment to the environment in the low probable event of an accident leading to core melt. Released from the fuel as a gaseous form, iodine enters the containment in gaseous or particulate form and undergoes deposition processes that eventually take it to the containment surfaces and sump. Once in the sump, iodine, when present as soluble compounds, gets dissolved as non volatile iodide (I-). Nonetheless, in the presence of radiation and particularly in acidic sumps, iodine can be oxidized to volatile forms such as molecular iodine (I 2 ) and can escape from the sump to the containment atmosphere (sump radiolysis process), thus increasing its potential contribution to the iodine source term. Iodine sump radiolysis has been extensively studied experimentally in the past decades. Experiments have revealed that parameters such as pH, temperature and total iodine concentration have a large impact on iodine volatility. However, experimental data at elevated temperatures (> 80 O C) and elevated dose rates (> 1 kGy.h -1 ) anticipated in containment during a postulated severe accident are too scarce to provide for these relevant conditions an accurate determination of the volatile iodine fractions. Furthermore, some data were obtained from post-irradiation analysis and iodine concentration may be underestimated at the time of measurements compared with that during irradiation, due to post-irradiation reactions. To complete the existing database, the EPICUR program was launched by IRSN (Institut de Radioprotection et de Surete Nucleaire) and experiments have been performed in the frame of the International Source Term Program (ISTP) to provide on

  17. Tumor containing fragment number influences immunohistochemistry positive rate of HER2 in biopsy specimens of gastric cancer.

    Science.gov (United States)

    Xu, Chen; Liu, Yalan; Ge, Xiaowen; Jiang, Dongxian; Zhang, Ying; Ji, Yuan; Hou, Jun; Huang, Jie; Su, Jieakesu; Zeng, Haiying; Qin, Jing; Hou, Yingyong

    2017-05-26

    HER2 assessment in biopsy specimens of gastric cancer (GC) is challenging because of the intratumoral heterogeneity. False negative results may be get because of limited biopsy material. The aim of this study is to explore how tumor-containing fragment number and biopsy specimen number affect HER2 immunohistochemistry (IHC) positive rate. Eight hundred and ninety biopsy specimens and 459 paired resected specimens were collected. IHC staining of HER2 was performed. HER2 IHC positive (scored 3+) rate was compared based on tumor-containing fragment number, biopsy specimen number, average size and tumor tissue proportion of tumor-containing fragments. The positive predictability of biopsy specimens to resected specimens was analyzed based on tumor fragment number. HER2 IHC positive rates were 2.0, 3.5, 7.0, 13.2, 17.1, and 15.9% when tumor fragment numbers were 1, 2, 3, 4, 5 and 6 respectively. The rate rose with the increase of tumor fragment number (P = 0.004). ROC curve analysis showed that biopsy specimens exhibited positive predictability when tumor fragment number reached 3, but showed better performance when the number was ≥4 (P fragment number reached 4, no statistic differences were reached in either HER2 IHC positive rate or positive predictability with further increase of the number (P > 0.05). HER2 IHC positive rate was not associated with biopsy number (P = 0.127), average size of tumor fragments (P = 0.397), and tumor tissue proportion of tumor fragments (P = 0.825) directly. The number of tumor-containing fragments influences HER2 IHC positive (scored 3+) rate. Greater than or equal to 4 (≥4) tumor fragments give better results in the positive rate as well as positive predictability. We recommend the number of tumor containing fragments be described in the HER2 IHC pathology reports for clinical reference in endoscopic biopsy specimens of GC.

  18. Development of a Self-Rating instrument to Measure Team Situation Awareness

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Koning, L. de; Hof, T.; Dongen, K. van

    2010-01-01

    The goal of this paper is to describe the development of an instrument to measure team situation awareness (TSA). Individual team member SA may or may not be shared through communication processes with other team members. Most existing instruments do not measure these processes but measure TSA as a

  19. Grip force and heart rate responses to manual carrying tasks: effects of material, weight, and base area of the container.

    Science.gov (United States)

    Lee, Tzu-Hsien; Tseng, Chia-Yun

    2014-01-01

    This study recruited 16 industrial workers to examine the effects of material, weight, and base area of container on reduction of grip force (ΔGF) and heart rate for a 100-m manual carrying task. This study examined 2 carrying materials (iron and water), 4 carrying weights (4.4, 8.9, 13.3, 17.8 kg), and 2 base areas of container (24 × 24 cm, 35 × 24 cm). This study showed that carrying water significantly increased ΔGF and heart rate as compared with carrying iron. Also, ΔGF and heart rate significantly increased with carrying weight and base area of container. The effects of base area of container on ΔGF and heart rate were greater in carrying water condition than in carrying iron condition. The maximum dynamic effect of water on ΔGF and heart rate occurred when water occupied ~60%-80% of full volume of the container.

  20. [The "Mini-ICF-Rating for Mental Disorders (Mini-ICF-P)". A short instrument for the assessment of disabilities in mental disorders].

    Science.gov (United States)

    Linden, M; Baron, S

    2005-06-01

    Supplementary to the description of diseases at symptom level, the International Classification of Functioning, Disability and Health (ICF), edited by the WHO, for the first time enables a systematic description also at the level of disabilities and impairments. The Mini-ICF-Rating for Mental Disorders (Mini-ICF-P) is a short observer rating instrument for the assessment of disabilities, especially with regard to occupational functioning. The Mini-ICF-P was first evaluated empirically in 125 patients of a Department of Behavioural Medicine and Psychosomatics. Parallel-test reliability was r = 0.59. Correlates were found with cognitive and motivational variables and duration of sick leave from work. In summary, the Mini-ICF-P is a quick and practicable instrument.

  1. Integrated leak rate test of the FFTF [Fast Flux Test Facility] containment vessel

    International Nuclear Information System (INIS)

    Grygiel, M.L.; Davis, R.H.; Polzin, D.L.; Yule, W.D.

    1987-04-01

    The third integrated leak rate test (ILRT) performed at the Fast Flux Test Facility (FFTF) demonstrated that effective leak rate measurements could be obtained at a pressure of 2 psig. In addition, innovative data reduction methods demonstrated the ability to accurately account for diurnal variations in containment pressure and temperature. Further development of methods used in this test indicate significant savings in the time and effort required to perform an ILRT on Liquid Metal Reactor Systems with consequent reduction in test costs

  2. Introduction to instrumentation and measurements

    CERN Document Server

    Northrop, Robert B

    2014-01-01

    Weighing in on the growth of innovative technologies, the adoption of new standards, and the lack of educational development as it relates to current and emerging applications, the third edition of Introduction to Instrumentation and Measurements uses the authors' 40 years of teaching experience to expound on the theory, science, and art of modern instrumentation and measurements (I&M). What's New in This Edition: This edition includes material on modern integrated circuit (IC) and photonic sensors, micro-electro-mechanical (MEM) and nano-electro-mechanical (NEM) sensors, chemical and radiation sensors, signal conditioning, noise, data interfaces, and basic digital signal processing (DSP), and upgrades every chapter with the latest advancements. It contains new material on the designs of micro-electro-mechanical (MEMS) sensors, adds two new chapters on wireless instrumentation and microsensors, and incorporates extensive biomedical examples and problems. Containing 13 chapters, this third edition: Describ...

  3. Cotrel-dubousset instrumentation for the correction of adolescent idiopathic scoliosis. Long-term results with an unexpected high revision rate

    Directory of Open Access Journals (Sweden)

    Mueller Franz J

    2012-06-01

    pain (LOSP. The average time until removal of instrumentation was 62.7 months (range 18 to 146 months post surgery; and one patient received partial device removal for prominent instrumentation 11 months post surgery. Altogether, only 22 out of 40 CD instrumentations (55% were still in situ. After an average period of 14.3 years post surgery, it was possible to follow-up 14 out of 40 patients (35% using the SRS-24 questionnaire. The average score was 93 points, without showing significant differences between patients with or without their instrumentation in situ. Conclusions Retrospectively, we documented for the first time a very high revisions rate in patients with AIS and treated by CD instrumentation. Nearly half of the instrumentation had to be removed due to late infection and LOSP. The reasons for the high rate of late infections with or without fistulae and for LOSP were analysed and discussed in detail.

  4. Exposure rates from concrete covered cylindrical units containing radioactive waste

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.

    1983-03-01

    Exposure rates from cylindrical waste units containing the nuclides 60 Co, 134 Cs and 137 Cs homogeneously mixed in a solidification product have been calculated. Analyses have been made for single drums and for two disposal geometries, one with the units placed below ground near the surface in a circular geometry, and one with the units placed on the ground in a pile behind a concrete wall. Due to self-shielding of the units, the exposure rate from the two geometries will be a factor of only 10 - 20 higher than from a single unit, even without soil or wall shielding. With one meter of soil above the circular pile below ground, a reduction factor of 5.10 3 to 5.10 4 can be achieved, depending on the nuclide considered. Placing a one-meter concrete wall in front of the drum pile on the ground gives rise to a reduction factor in the range of 5.10 5 to 2.10 7 . (author)

  5. Measuring participants' immersion in healthcare simulation: the development of an instrument.

    Science.gov (United States)

    Hagiwara, Magnus Andersson; Backlund, Per; Söderholm, Hanna Maurin; Lundberg, Lars; Lebram, Mikael; Engström, Henrik

    2016-01-01

    Immersion is important for simulation-based education; however, questionnaire-based instruments to measure immersion have some limitations. The aim of the present work is to develop a new instrument to measure immersion among participants in healthcare simulation scenarios. The instrument was developed in four phases: trigger identification, content validity scores, inter-rater reliability analysis and comparison with an existing immersion measure instrument. A modified Delphi process was used to develop the instrument and to establish validity and reliability. The expert panel consisted of 10 researchers. All the researchers in the team had previous experience of simulation in the health and/or fire and rescue services as researchers and/or educators and simulation designers. To identify triggers, the panel members independently screened video recordings from simulation scenarios. Here, a trigger is an event in a simulation that is considered a sign of reduced or enhanced immersion among simulation participants. The result consists of the Immersion Score Rating Instrument (ISRI). It contains 10 triggers, of which seven indicate reduced and three enhanced immersion. When using ISRI, a rater identifies trigger occurrences and assigns them strength between 1 and 3. The content validity analysis shows that all the 10 triggers meet an acceptable content validity index for items (I-CVI) standard. The inter-rater reliability (IRR) among raters was assessed using a two-way mixed, consistency, average-measures intra-class correlation (ICC). The ICC for the difference between weighted positive and negative triggers was 0.92, which indicates that the raters are in agreement. Comparison with results from an immersion questionnaire mirrors the ISRI results. In conclusion, we present a novel and non-intrusive instrument for identifying and rating the level of immersion among participants in healthcare simulation scenarios.

  6. Influence of container design on predation rate of potential biocontrol agent, Toxorhynchites splendens (Diptera: Culicidae) against dengue vector.

    Science.gov (United States)

    Mohamad, N; Zuharah, W F

    2014-03-01

    Toxorhynchites splendens larvae are a natural predator of dengue vector mosquito larvae, Aedes albopictus. This study was carried out to evaluate the predation rate of Tx. splendens third instar larvae on Ae. albopictus larvae in 24 h. Each predator was offered prey at a density between 10 to 50 individuals. Predation rate of Tx. splendens were also tested with two manipulated factors; various types of container and different water volumes. The experiment was evaluated in man-made containers (tin cans, plastic drinking glasses and rubber tires) and natural container (bamboo stumps) which were filled with different water volumes (full, half full, 1/4 full, and 1/8 full). The prey density and the characteristics of the container were found as significant factors which influence the predation rate of Tx. splendens. The predator consumed significantly more prey at higher prey densities (40 and 50 preys) compared to the lowest density (10 preys) (F=3.935, df=4, p=0.008). The results showed significantly higher consumption in horizontal shaped container of rubber tire than in vertical shape of bamboo stumps (F=3.100, df=3, p=0.029). However, the water volume had no significant effect on predation rate of Tx. splendens (F=1.736, df=3, p=0.162). We generally suggest that Tx. splendens is best to be released in discarded tires or any other containers with horizontal shape design with wide opening since Tx. splendens can become more effective in searching prey in this type of container design. This predator is also a suitable biocontrol candidates to be introduced either in wet and dry seasons in Malaysia.

  7. FMIT diagnostic instrumentation

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Chamberlin, D.D.

    1985-01-01

    The Fusion Materials Irradiation Test facility (FMIT) cw prototype accelerator has noninterceptive beamline instrumentation to measure beam parameters. The transverse emittances and beam profiles are measured with an array of photodiode sensors viewing light emitted from the beam region. Tomographic reconstructions of both spatial-density distributions and of transverse-emittance distributions are performed throughout a quadrupole focusing section. Beam bunches passing through capacitive probes produce bipolar waveforms whose zero crossing corresponds to the bunch's longitudinal centroid. By measuring the time required for a bunch to travel the known distance between two probes, velocity and energy are determined. A toroidal transformer measures the average ac beam current. Beam spill is measured by a set of movable jaws that intercept the beam edges. Each jaw contains a water flow channel whose flow rate and differential temperature are measured to derive a transverse power distribution. Beam centroid position is measured by a four-lobe, magnetic-loop pickup. 5 refs., 6 figs

  8. Dose rate mapping and quantitative analysis of radioactive deposition with simple monitoring instruments in Finland after the Chernobyl accident.

    Energy Technology Data Exchange (ETDEWEB)

    Koivukoski, J. [Ministry of the Interior, Rescue Dept., Helsinki (Finland); Paatero, J. [Finnish Meteorological Inst., Helsinki (Finland)], E-mail: janne.koivukoski@intermin.fi

    2013-03-01

    This article reviews the Finnish dose-rate mapping equipment and the system to process the obtained results, which were used immediately after the 1986 Chernobyl accident. We present the results of the external gamma-radiation monitoring carried out with simple civil-defence gamma monitoring instruments and compare them with the subsequent deposition mapping performed with research-grade instruments. The analysis shows that the quality of radiation mapping is good enough for decision makers to direct protective measures to the right areas. This review also demonstrates that a simple stationary external gamma radiation monitoring network can be effectively used for early warning in radiation emergency situations. (orig.)

  9. Calibration of solar radiation measuring instruments. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bahm, R J; Nakos, J C

    1979-11-01

    A review of solar radiation measurement of instruments and some types of errors is given; and procedures for calibrating solar radiation measuring instruments are detailed. An appendix contains a description of various agencies who perform calibration of solar instruments and a description of the methods they used at the time this report was prepared. (WHK)

  10. Radionuclide mass transfer rates from a pinhole in a waste container for an inventory-limited and a constant concentration source

    International Nuclear Information System (INIS)

    LeNeveu, D.M.

    1996-03-01

    Analytical solutions for transient and steady state diffusive mass transfer rates from a pinhole in a waste container are developed for constant concentration and inventory-limited source conditions. Mass transport in three media are considered, inside the pinhole (medium 2), outside the container (medium 3) and inside the container (medium 1). Simple equations are developed for radionuclide mass transfer rates from a pinhole. It is shown that the medium with the largest mass transfer resistance need only be considered to provide a conservative estimate of mass transfer rates. (author) 11 refs., 3 figs

  11. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1976-01-01

    Reference is made to the instrumentation of liquid metal cooled fast reactors. In order to ensure the safe operation of such reactors it is necessary to constantly monitor the coolant flowing through the fuel assemblies for temperature and rate of flow, requiring a large number of sensors. An improved and simplified arrangement is claimed in which the fuel assemblies feed a fraction of coolant to three instrument units arranged to sense the temperature and rate of flow of samples of coolant. Each instrument unit comprises a sleeve housing a sensing unit and has a number of inlet ducts arranged for receiving coolant from a fuel assembly together with a single outlet. The sensing unit has three thermocouple hot junctions connected in series, the hot junctions and inlet ducts being arranged in pairs. Electromagnetic windings around an inductive core are arranged to sense variation in flow of liquid metal by flux distortion. Fission product sensing means may also be provided. Full constructional details are given. (U.K.)

  12. Technological considerations in emergency instrument preparedness

    International Nuclear Information System (INIS)

    Selby, J.M.

    1975-01-01

    The types of emergency instrumentation systems necessary to characterize the severity and extent of radiation accidents and to aid in the protection of operating personnel and personnel living near the plant are discussed. These include instruments for direct measurement of the airborne radioactive material within the facility, fixed instrumentation for ambient dose rate monitoring or area monitoring, and portable instruments for environmental monitoring

  13. Proceedings of the Scientific Meeting in Nuclear Instrumentation Engineering

    International Nuclear Information System (INIS)

    Achmad Suntoro; Rony Djokorayono; Ferry Sujatno; Utaja

    2010-11-01

    The Proceeding of the Scientific Meeting in Nuclear Instrumentation Engineering held on Nov, 30, 2010 by the Centre for Nuclear Instrumentation Engineering - National Nuclear Energy Agency. The Proceedings of the Scientific Contains 40 papers Consist of Nuclear Instrumentation Engineering for Industry, Environment, and Nuclear Facilities. (PPIKSN)

  14. An Integrated Instrumentation System for Velocity, Concentration and Mass Flow Rate Measurement of Solid Particles Based on Electrostatic and Capacitance Sensors

    Directory of Open Access Journals (Sweden)

    Jian Li

    2015-12-01

    Full Text Available The online and continuous measurement of velocity, concentration and mass flow rate of pneumatically conveyed solid particles for the high-efficiency utilization of energy and raw materials has become increasingly significant. In this paper, an integrated instrumentation system for the velocity, concentration and mass flow rate measurement of dense phase pneumatically conveyed solid particles based on electrostatic and capacitance sensorsis developed. The electrostatic sensors are used for particle mean velocity measurement in combination with the cross-correlation technique, while the capacitance sensor with helical surface-plate electrodes, which has relatively homogeneous sensitivity distribution, is employed for the measurement of particle concentration and its capacitance is measured by an electrostatic-immune AC-based circuit. The solid mass flow rate can be further calculated from the measured velocity and concentration. The developed instrumentation system for velocity and concentration measurement is verified and calibrated on a pulley rig and through static experiments, respectively. Finally the system is evaluated with glass beads on a gravity-fed rig. The experimental results demonstrate that the system is capable of the accurate solid mass flow rate measurement, and the relative error is within −3%–8% for glass bead mass flow rates ranging from 0.13 kg/s to 0.9 kg/s.

  15. Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion.

    Science.gov (United States)

    Madan, S S; Boeree, N R

    2003-12-01

    the ALIF group and 74.3% (26 patients) in the PLIF group (P>0.05). On categorising Oswestry Index scores into "excellent", "better", "same", and "worse", we found no difference in outcome between the two groups: 79.5% (n=31) had satisfactory outcome with ALIF and 80% (n=28) had satisfactory outcome with PLIF. The rate of return to work was no different in the two groups. On radiological assessment, we found two nonunions in the circumferential fusion (PLIF) group (94.3% fusion rate) and indirect evidence of no nonunions in the ALIF group. There was no significant difference between the compensation rate and disability benefit rate between the two groups. There were three complications in ALIF group and four in the PLIF (circumferential) group. On the basis of these results, we conclude that it is possible to treat discogenic back pain by anterior interbody fusion with Hartshill horseshoe cage or with circumferential fusion using instrumented PLIF.

  16. Collection of radiation resistant characteristics reports for instruments and materials in high dose rate environment

    International Nuclear Information System (INIS)

    Kusano, Joichi

    2008-03-01

    This document presents the collected official reports of radiation irradiation study for the candidate materials to be used in high dose rate environment as J-PARC facility. The effect of radiation damage by loss-beam or secondary particle beam of the accelerators influences the performance and the reliability of various instruments. The knowledge on the radiation resistivity of the materials is important to estimate the life of the equipments, the maintenance interval and dose evaluation for the personnel at the maintenance period. The radiation damage consists with mechanical property, electrical property and gas-evolution property. (author)

  17. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  18. Rate and time to develop first central line-associated bloodstream infections when comparing open and closed infusion containers in a Brazilian Hospital

    Directory of Open Access Journals (Sweden)

    Margarete Vilins

    Full Text Available The objective of the study was to determine the effect of switching from an open (glass or semi-rigid plastic infusion container to a closed, fully collapsible plastic infusion container (Viaflex® on rate and time to onset of central lineassociated bloodstream infections (CLABSI. An open-label, prospective cohort, active healthcare-associated infection surveillance, sequential study was conducted in three intensive care units in Brazil. The CLABSI rate using open infusion containers was compared to the rate using a closed infusion container. Probability of acquiring CLABSI was assessed over time and compared between open and closed infusion container periods; three-day intervals were examined. A total of 1125 adult ICU patients were enrolled. CLABSI rate was significantly higher during the open compared with the closed infusion container period (6.5 versus 3.2 CLABSI/1000 CL days; RR=0.49, 95%CI=0.26- 0.95, p=0.031. During the closed infusion container period, the probability of acquiring a CLABSI remained relatively constant along the time of central line use (0.8% Days 2-4 to 0.7% Days 11-13 but increased in the open infusion container period (1.5% Days 2-4 to 2.3% Days 11-13. Combined across all time intervals, the chance of a patient acquiring a CLABSI was significantly lower (55% in the closed infusion container period (Cox proportional hazard ratio 0.45, p= 0.019. CLABSIs can be reduced with the use of full barrier precautions, education, and performance feedback. Our results show that switching from an open to a closed infusion container may further reduce CLABSI rate as well as delay the onset of CLABSIs. Closed infusion containers significantly reduced CLABSI rate and the probability of acquiring CLABSI.

  19. The plant-specific impact of different pressurization rates in the probabilistic estimation of containment failure modes

    International Nuclear Information System (INIS)

    Ahn, Kwang Il; Yang, Joon Eon; Ha, Jae Joo

    2003-01-01

    The explicit consideration of different pressurization rates in estimating the probabilities of containment failure modes has a profound effect on the confidence of containment performance evaluation that is so critical for risk assessment of nuclear power plants. Except for the sophisticated NUREG-1150 study, many of the recent containment performance analyses (through level 2 PSAs or IPE back-end analyses) did not take into account an explicit distinction between slow and fast pressurization in their analyses. A careful investigation of both approaches shows that many of the approaches adopted in the recent containment performance analyses exactly correspond to the NUREG-1150 approach for the prediction of containment failure mode probabilities in the presence of fast pressurization. As a result, it was expected that the existing containment performance analysis results would be subjected to greater or less conservatism in light of the ultimate failure mode of the containment. The main purpose of this paper is to assess potential conservatism of a plant-specific containment performance analysis result in light of containment failure mode probabilities

  20. APPLICATION OF THE SPECTROMETRIC METHOD FOR CALCULATING THE DOSE RATE FOR CREATING CALIBRATION HIGHLY SENSITIVE INSTRUMENTS BASED ON SCINTILLATION DETECTION UNITS

    Directory of Open Access Journals (Sweden)

    R. V. Lukashevich

    2017-01-01

    Full Text Available Devices based on scintillation detector are highly sensitive to photon radiation and are widely used to measure the environment dose rate. Modernization of the measuring path to minimize the error in measuring the response of the detector to gamma radiation has already reached its technological ceiling and does not give the proper effect. More promising for this purpose are new methods of processing the obtained spectrometric information. The purpose of this work is the development of highly sensitive instruments based on scintillation detection units using a spectrometric method for calculating dose rate.In this paper we consider the spectrometric method of dosimetry of gamma radiation based on the transformation of the measured instrumental spectrum. Using predetermined or measured functions of the detector response to the action of gamma radiation of a given energy and flux density, a certain function of the energy G(E is determined. Using this function as the core of the integral transformation from the field to dose characteristic, it is possible to obtain the dose value directly from the current instrumentation spectrum. Applying the function G(E to the energy distribution of the fluence of photon radiation in the environment, the total dose rate can be determined without information on the distribution of radioisotopes in the environment.To determine G(E by Monte-Carlo method instrumental response function of the scintillator detector to monoenergetic photon radiation sources as well as other characteristics are calculated. Then the whole full-scale energy range is divided into energy ranges for which the function G(E is calculated using a linear interpolation.Spectrometric method for dose calculation using the function G(E, which allows the use of scintillation detection units for a wide range of dosimetry applications is considered in the article. As well as describes the method of calculating this function by using Monte-Carlo methods

  1. A new Loan-Stock Financial Instrument

    OpenAIRE

    Morozovsky, Alexander; Narasimhan, Rajan; Kholodenko, Yuri

    2000-01-01

    A new financial instrument (a new kind of a loan) is introduced. The loan-stock instrument (LSI) combines fixed rate instruments (loans, etc.) with other financial instruments that have higher volatilities and returns (stocks, mutual funds, currencies, derivatives, options, etc.). This new loan depends on the value of underlying security (for example, stock) in such a way that when underlying security increases, the value of loan decreases and backwards. The procedure to create a risk free po...

  2. Rotary mode system initial instrument calibration

    International Nuclear Information System (INIS)

    Johns, B.R.

    1994-01-01

    The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files

  3. Derivative financial instruments and nonprofit health care providers.

    Science.gov (United States)

    Stewart, Louis J; Owhoso, Vincent

    2004-01-01

    This article examines the extent of derivative financial instrument use among US nonprofit health systems and the impact of these financial instruments on their cash flows, reported operating results, and financial risks. Our examination is conducted through a case study of New Jersey hospitals and health systems. We review the existing literature on interest rate derivative instruments and US hospitals and health systems. This literature describes the design of these derivative financial instruments and the theoretical benefits of their use by large health care provider organizations. Our contribution to the literature is to provide an empirical evaluation of derivative financial instruments usage among a geographically limited sample of US nonprofit health systems. We reviewed the audited financial statements of the 49 community hospitals and multi-hospital health systems operating in the state of New Jersey. We found that 8 percent of New Jersey's nonprofit health providers utilized interest rate derivatives with an aggregate principle value of $229 million. These derivative users combine interest rate swaps and caps to lower the effective interest costs of their long-term debt while limiting their exposure to future interest rate increases. In addition, while derivative assets and liabilities have an immaterial balance sheet impact, derivative related gains and losses are a material component of their reported operating results. We also found that derivative usage among these four health systems was responsible for generating positive cash flows in the range of 1 percent to 2 percent of their total 2001 cash flows from operations. As a result of our admittedly limited samples we conclude that interest rate swaps and caps are effective risk management tools. However, we also found that while these derivative financial instruments are useful hedges against the risks of issuing long-term financing instruments, they also expose derivative users to credit, contract

  4. Nuclear instrument technician training

    International Nuclear Information System (INIS)

    Wollesen, E.S.

    1991-01-01

    This paper reports on Nuclear Instrument Technician (NIT) training that has developed at an accelerated rate over the past three decades. During the 1960's commercial nuclear power plants were in their infancy. For that reason, there is little wonder that NIT training had little structure and little creditability. NIT training, in many early plants, was little more than On-The Job Training (OJT). The seventies brought changes in Instrumentation and Controls as well as emphasis on the requirements for more in depth training and documentation. As in the seventies, the eighties saw not only changes in technologies but tighter requirements, standardized training and the development of accredited Nuclear Instrument Training; thus the conclusion: Nuclear Instrument Training Isn't What It Used To Be

  5. Project W-314 DST and DCRT instrument and control systems, initial assessment

    International Nuclear Information System (INIS)

    Acree, C.D.

    1996-01-01

    This report contains an assessment of the instrument and control systems in the Double Shell Tank Farms and the 244-A DCRT. The assessment report contains data from physical inspection activities and an overall engineering assessment of the instruments and control systems in use in the Double Shell Tanks

  6. Modelling global container freight transport demand

    NARCIS (Netherlands)

    Tavasszy, L.A.; Ivanova, O.; Halim, R.A.

    2015-01-01

    The objective of this chapter is to discuss methods and techniques for a quantitative and descriptive analysis of future container transport demand at a global level. Information on future container transport flows is useful for various purposes. It is instrumental for the assessment of returns of

  7. Delayed phenomena analysis from French PWR containment instrumentation system

    International Nuclear Information System (INIS)

    Costaz, J.L.

    1987-01-01

    The analysis of the large amount of measurements which has been now gathered by EDF on its twenty two PWR 900 MW shows that the behaviour of concrete under creep and shrinkage effects is in good agreement with the values given as correct estimates by french regulations and taken into account for the design of nuclear prestressed structures. None of the containment buildings studied here showed significant differences with the regulations theoretical values and consequently all the measurements remain in the field of the allowable strain variations used for design. On the other hand, if the instant loading elastic modulus is clearly determined for each containment, and its effect on theoretical creep taken into account, it was not possible up till now to extract from measurements some particular effects such as type of concrete and agregates or climatic effects. (orig.)

  8. Assessment and management of ageing of major nuclear power plant components important to safety: In-containment instrumentation and control cables. Volume I

    International Nuclear Information System (INIS)

    2000-12-01

    and technical support organizations dealing with specific plant components addressed in the reports. The component addressed in the present report is the in-containment instrumentation and control (I and C) cables. The report presents, in two volumes, results of a Co-ordinated Research Project (CRP) on the Management of Ageing of In-containment Instrumentation and Control cables. Part I, Volume 1 presents information on current methods for assessing and managing ageing degradation of Instrumentation and Control cables in real NPP environments prepared by the CRP team. An important complement of this information is user perspectives on the application of these methods which are presented in Part II, Volume 1. Volume 2 contains annexes supporting the guidance of Volume 1 with more detailed information and examples provided by individual CRP participants. For a quick overview, readers should see Section 8 of Part I, Volume 1, which describes a systematic ageing management programme for Instrumentation and Control cables utilizing methods presented in the report; Section 9 of Part I, Volume 1, which presents CRP conclusions and recommendations; and Part II providing the application guidance from the user's perspective

  9. Assessment and management of ageing of major nuclear power plant components important to safety: In-containment instrumentation and control cables. Volume II

    International Nuclear Information System (INIS)

    2000-12-01

    and technical support organizations dealing with specific plant components addressed in the reports. The component addressed in the present report is the in-containment instrumentation and control (I and C) cables. The report presents, in two volumes, results of a Co-ordinated Research Project (CRP) on the Management of Ageing of In-containment Instrumentation and Control cables. Part I, Volume 1 presents information on current methods for assessing and managing ageing degradation of Instrumentation and Control cables in real NPP environments prepared by the CRP team. An important complement of this information is user perspectives on the application of these methods which are presented in Part II, Volume 1. Volume 2 contains annexes supporting the guidance of Volume 1 with more detailed information and examples provided by individual CRP participants. For a quick overview, readers should see Section 8 of Part I, Volume 1, which describes a systematic ageing management programme for Instrumentation and Control cables utilizing methods presented in the report; Section 9 of Part I, Volume 1, which presents CRP conclusions and recommendations; and Part II providing the application guidance from the user's perspective

  10. Multi-Institutional Development of a Mastoidectomy Performance Evaluation Instrument.

    Science.gov (United States)

    Kerwin, Thomas; Hittle, Brad; Stredney, Don; De Boeck, Paul; Wiet, Gregory

    A method for rating surgical performance of a mastoidectomy procedure that is shown to apply universally across teaching institutions has not yet been devised. This work describes the development of a rating instrument created from a multi-institutional consortium. Using a participatory design and a modified Delphi approach, a multi-institutional group of expert otologists constructed a 15-element task-based checklist for evaluating mastoidectomy performance. This instrument was further refined into a 14-element checklist focusing on the concept of safety after using it to rate a large and varied population of performances. Twelve otolaryngological surgical training programs in the United States. A total of 14 surgeons from 12 different institutions took part in the construction of the instrument. By using 14 experts from 12 different institutions and a literature review, individual metrics were identified, rated as to the level of importance and operationally defined to create a rating scale for mastoidectomy performance. Initial use of the rating scale showed modest rater agreement. The operational definitions of individual metrics were modified to emphasize "safe" as opposed to "proper" technique. A second rating instrument was developed based on this feedback. Using a consensus-building approach with multiple rounds of communication between experts is a feasible way to construct a rating instrument for mastoidectomy. Expert opinion alone using a Delphi method provides face and content validity evidence, however, this is not sufficient to develop a universally acceptable rating instrument. A continued process of development and experimentation to demonstrate evidence for reliability and validity making use of a large population of raters and performances is necessary to achieve universal acceptance. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  11. Protective interest rate as tax instrument of corporate capital protection

    Directory of Open Access Journals (Sweden)

    Vukašinović Jovan

    2015-01-01

    Full Text Available This paper deals with researching negative consequences of allocation of economic (virtual gains made as a result of conventional accounting concept by facing current income with historical expenses and necessity to promote additional stimulating instruments that are at disposal by the state in order to eliminate these negative consequences. one of them is certainly protective interest as a relatively new active fiscal instrument of capital protection and recognition of price of invested owner's equity in business ventures, i.e. a specific form of compensation by the state for invested capital bearing in mind, that no source is free, including ones own sources. We also showed mechanisms of protective interest which, together with other measures of macroeconomic policy, should contribute to the protection of real purchasing power of company equity and increase of net gain, left on company's disposal for new investments, new work places, more money in the budget, protection of actual assets against taxing in the conditions of inflation, etc.

  12. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  13. Monetary Policy Instruments and Bank Risks in China

    OpenAIRE

    Zhongyuan Geng; Xue Zhai

    2013-01-01

    The authors use a panel data regression model to examine the effects of main monetary policy instruments on commercial bank risks in China from 1998 to 2011. The interest rate has a positive effect on bank risk while the interest rate margin, the reserve requirement ratio and open market operation have a negative effect. Among the three monetary policy instruments, the reserve requirement ratio has the greatest effect on bank risk, the interest rate (the interest rate margin) the second large...

  14. Pre-validation methods for developing a patient reported outcome instrument

    Directory of Open Access Journals (Sweden)

    Castillo Mayret M

    2011-08-01

    Full Text Available Abstract Background Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology. Methods The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ. The five steps are: 1 Generation of a pool of items; 2 Item de-duplication (three phases; 3 Item reduction (two phases; 4 Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF; and 5 qualitative exploration of the target populations' views of the new instrument and the items it contains. Results The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items. Conclusions This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped

  15. The Children's Sleep Comic: Psychometrics of a Self-rating Instrument for Childhood Insomnia.

    Science.gov (United States)

    Schwerdtle, Barbara; Kanis, Julia; Kübler, Andrea; Schlarb, Angelika A

    2016-02-01

    The Children's Sleep Comic is a standardized self-report questionnaire for assessing insomnia in children ages 5-11 years. The goal of the present study is to introduce a revised version of this measure and to present psychometrics and a cut-off score. Therefore, the revised Children's Sleep Comic, the Sleep Self Report, the Children's Sleep Habits Questionnaire, and the Child Behavior Checklist were applied to a sample of 393 children and their parents. Of the parents who participated voluntarily, a subsample (n = 176) was interviewed on the phone to diagnose their children with sleep disorders according to the International Classification of Sleep Disorders, if applicable. The results indicated that the Children's Sleep Comic is a reliable self-rating instrument for diagnosing childhood insomnia. Internal consistency was α = 0.83; and convergent and divergent validity were adequate. The child-friendly format can foster a good therapeutic relationship, and thus establish the basis for successful intervention.

  16. Corrosion rate of steel in concrete - Evaluation of confinement techniques for on-site corrosion rate

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica; Elsener, Bernhard

    2009-01-01

    Earlier on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when different commercially available instruments are used. The different confinement techniques, rather than the different electrochemical techniques used in the instruments, are considered...... to be the main reason for the discrepancies. This paper presents a method for the quantitative assessment of confinement techniques based on monitoring the operation of the corrosion rate instrument and the current distribution between the electrode assembly on the concrete surface and a segmented reinforcement...... bar embedded in the concrete. The applicability of the method was demonstrated on two commercially available corrosion rate instruments based on different confinement techniques. The method provided an explanation of the differences in performance of the two instruments. Correlated measurements...

  17. Maintenance of nuclear medicine instruments in developing countries

    International Nuclear Information System (INIS)

    1976-01-01

    This report reviews the current nature and severity of the problems related to nuclear medicine instruments in developing countries and gives the recommendations of the Advisory Group on the development of improved strategies to assure that the instruments are effectively maintained while in use. A compilation of data from the Register of Medical Radioisotope Units (IAEA-167) on medical radioisotope instrumentation installed in developing countries and some comments and suggestions contained in reports of Agency Technical Assistance Experts are also presented

  18. Developing a workplace resilience instrument.

    Science.gov (United States)

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  19. Safeguards instrumentation: past, present, future

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    1982-01-01

    Instruments are essential for accounting, for surveillance and for protection of nuclear materials. The development and application of such instrumentation is reviewed, with special attention to international safeguards applications. Active and passive nondestructive assay techniques are some 25 years of age. The important advances have been in learning how to use them effectively for specific applications, accompanied by major advances in radiation detectors, electronics, and, more recently, in mini-computers. The progress in seals has been disappointingly slow. Surveillance cameras have been widely used for many applications other than safeguards. The revolution in TV technology will have important implications. More sophisticated containment/surveillance equipment is being developed but has yet to be exploited. On the basis of this history, some expectations for instrumentation in the near future are presented

  20. Teen drivers' awareness of vehicle instrumentation in naturalistic research.

    Science.gov (United States)

    Ehsani, J P; Haynie, D; Ouimet, M C; Zhu, C; Guillaume, C; Klauer, S G; Dingus, T; Simons-Morton, B G

    2017-12-01

    Naturalistic driving methods require the installation of instruments and cameras in vehicles to record driving behavior. A critical, yet unexamined issue in naturalistic driving research is the extent to which the vehicle instruments and cameras used for naturalistic methods change human behavior. We sought to describe the degree to which teenage participants' self-reported awareness of vehicle instrumentation changes over time, and whether that awareness was associated with driving behaviors. Forty-two newly-licensed teenage drivers participated in an 18-month naturalistic driving study. Data on driving behaviors including crash/near-crashes and elevated gravitational force (g-force) events rates were collected over the study period. At the end of the study, participants were asked to rate the extent to which they were aware of instruments in the vehicle at four time points. They were also asked to describe their own and their passengers' perceptions of the instrumentation in the vehicle during an in-depth interview. The number of critical event button presses was used as a secondary measure of camera awareness. The association between self-reported awareness of the instrumentation and objectively measured driving behaviors was tested using correlations and linear mixed models. Most participants' reported that their awareness of vehicle instrumentation declined across the duration of the 18-month study. Their awareness increased in response to their passengers' concerns about the cameras or if they were involved in a crash. The number of the critical event button presses was initially high and declined rapidly. There was no correlation between driver's awareness of instrumentation and their crash and near-crash rate or elevated g-force events rate. Awareness was not associated with crash and near-crash rates or elevated g-force event rates, consistent with having no effect on this measure of driving performance. Naturalistic driving studies are likely to yield

  1. Instrument for track linear element recognition

    International Nuclear Information System (INIS)

    Krupnov, V.E.; Fedotov, O.P.

    1977-01-01

    Described is the construction of instrument for recognizing linear elements of tracks. For designing this instrument use has been made of the algorithm for conversion of the point data into a set of linear elements. The flowsheet of the instrument shows its major units such as data converter, data representation register unit, local computers, interface with the central computer. The data representation register unit comprises sixteen registers and is capable of presenting data from sixteen lines when raster scanning of a picture taken from a track chamber. The maximum capacity of the code of the coordinate of a point recorded on a picture is up to 16 digits. The time of the inner operating cycle of the instrument is 1.3 μs. The average time required for processing data containing sixteen scanning lines is 250 μs

  2. Technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun Nuclear Power Plant

    International Nuclear Information System (INIS)

    Hackett, D.B.

    1980-01-01

    This report documents the technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun nuclear power plant. The review criteria are based on IEEE Std-279-1971 requirements for the safety signals to all purge and ventilation isolation valves. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Program being conducted for the US Nuclear Regulatory Commission by Lawrence Livermore Laboratory

  3. Data acquisition instruments: Psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III

    1998-01-01

    This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended. In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.

  4. Bright THz Instrument and Nonlinear THz Science

    Science.gov (United States)

    2017-10-30

    Report: Bright THz Instrument and Nonlinear THz Science The views, opinions and/or findings contained in this report are those of the author(s) and...Number: W911NF-16-1-0436 Organization: University of Rochester Title: Bright THz Instrument and Nonlinear THz Science Report Term: 0-Other Email: xi...exploring new cutting-edge research and broader applications, following the significant development of THz science and technology in the late 80’s, is the

  5. The effect of devitrification on leaching rate of glass containing simulated high level liquid waste (HLLW)

    International Nuclear Information System (INIS)

    Suryantoro; Sumarbagiono; Martono, H.

    1996-01-01

    Effect of devitrification on leaching rate of glass named G1 and G2 each contains 20 wt% and 30wt% of waste has been studied. devitrification of waste - glass has been carried out by heating those specimens at 850 o C for 10, 18, 26, 34, 42 and 50 hours respectively. The weight percentage of crystal in waste glass was determined by X-ray diffractometer and leaching rate was determined by soxhlet apparatus at 100 o C for 24 hours. The longer heating time, the more weight percentage of crystal is formed. The results show that leaching rate of G2 specimens are higher than those of G1. For G1 the leaching rate at 850 o C in 20 times than without heating, and for G2 leaching rate is 15.7 times than without heating. (author)

  6. A Prospective, Multicenter Study to Compare a Disposable, High-fluid Capacity Underpad to Nonpermeable, Disposable, Reusable Containment Products on Incontinence-associated Dermatitis Rates Among Skilled Nursing Facility Residents.

    Science.gov (United States)

    Motta, Glenda; Milne, Catherine T

    2017-12-01

    Due to the high prevalence of incontinence among skilled nursing facility (SNF) residents, incontinence-associated derma- titis (IAD) is a common occurrence. In addition, facility staff may mistakenly identify IAD as a pressure injury. A prospective, descriptive, multicenter study was conducted in 3 Connecticut facilities to evaluate the effect of substituting a disposable, high- uid capacity underpad for nonpermeable disposable and reusable containment products on the rate of IADs. Residents with and without IAD but with high IAD risk scores who were bed- or chairbound or ambulatory and used disposable nonpermeable briefs and underpads or reusable, laundered containment products when in bed longer than 2 hours were randomly enrolled and observed for a 4-week period. Facility staff were trained on the importance of differentiating between IAD and pressure injury; they substituted the study product (a disposable, high- uid capacity underpad) for all previously used containment products. Patient risk for IAD and skin condition were assessed using the Perineal Assessment Tool (PAT) and the Skin Condition Assessment Tool (SAT), respectively, at 5 time points: baseline, week 1, week 2, week 3, and week 4. The PAT is a 4-item instrument based conceptually on the 4 determinants in perineal skin breakdown; subscales are rated from 1 (least risk) to 3 (most risk), with a total score range of 4 to 12. The SAT is used to evaluate IAD speci cally, generating a cumulative severity score ranging from 0 to 3 on area of skin affected, degree of redness, and depth of ero- sion. Final data analysis was conducted on 40 residents: 25 had IAD present at enrollment and 15 were deemed high risk for developing IAD. Mean SAT scores in the 25 participants with IAD decreased with signi cance at week 1 (P = .0016), week 2 (P = .0023), week 3 (P = .0005), and week 4 (P disposable, high- uid capacity underpad improved SAT scores over time. IAD rates increased in each facility, but pressure

  7. Design and fabrication of non-instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility.

  8. Design and fabrication of non-instrumented capsule

    International Nuclear Information System (INIS)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility

  9. The cross-cultural equivalence of participation instruments: a systematic review.

    Science.gov (United States)

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    Concepts such as health-related quality of life, disability and participation may differ across cultures. Consequently, when assessing such a concept using a measure developed elsewhere, it is important to test its cultural equivalence. Previous research suggested a lack of cultural equivalence testing in several areas of measurement. This paper reviews the process of cross-cultural equivalence testing of instruments to measure participation in society. An existing cultural equivalence framework was adapted and used to assess participation instruments on five categories of equivalence: conceptual, item, semantic, measurement and operational equivalence. For each category, several aspects were rated, resulting in an overall category rating of 'minimal/none', 'partial' or 'extensive'. The best possible overall study rating was five 'extensive' ratings. Articles were included if the instruments focussed explicitly on measuring 'participation' and were theoretically grounded in the ICIDH(-2) or ICF. Cross-validation articles were only included if it concerned an adaptation of an instrument developed in a high or middle-income country to a low-income country or vice versa. Eight cross-cultural validation studies were included in which five participation instruments were tested (Impact on Participation and Autonomy, London Handicap Scale, Perceived Impact and Problem Profile, Craig Handicap Assessment Reporting Technique, Participation Scale). Of these eight studies, only three received at least two 'extensive' ratings for the different categories of equivalence. The majority of the cultural equivalence ratings given were 'partial' and 'minimal/none'. The majority of the 'none/minimal' ratings were given for item and measurement equivalence. The cross-cultural equivalence testing of the participation instruments included leaves much to be desired. A detailed checklist is proposed for designing a cross-validation study. Once a study has been conducted, the checklist can

  10. Safeguards instrumentation: a computer-based catalog. Second edition

    International Nuclear Information System (INIS)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community

  11. Safeguards instrumentation: a computer-based catalog. Second edition

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community.

  12. A 'hybrid' neutron area survey instrument for the determination of neutron dose quantities in the workplace

    International Nuclear Information System (INIS)

    Tanner, R.J.; Jenkins, R.; Lowe, T.; Silvie, J.; Joyce, M.J.; Winsby, A.; Molinos, C.

    2005-01-01

    Full text: Neutron survey instruments are used routinely to determine the dose rates in areas where persons may be occupationally exposed. With a few exceptions, these instruments generally use a proportional counter with a high thermal neutron response located in a moderating sphere of CH 2 . The moderating sphere in such designs contains a thermal neutron absorber to reduce the over-response to thermal and intermediate energy neutrons. However, the commercially available examples of such instruments tend to have strongly energy dependent ambient dose equivalent response characteristics. In particular, they often over-respond in the energy range between 1 eV and 10 keV. A prototype of a novel design has been produced that uses seven detectors located in a moderating sphere of CH 2 , six near the surface to detect thermal and epithermal neutrons, and one in the centre to detect fast neutrons. This has been characterized using a combination of MCNP modelling and measurements to produce an instrument that has improved energy dependence of response characteristics. Additionally, the use of seven detectors offers direction and field hardness information. The design and calibration of the instrument are described and its response in workplaces calculated. (author)

  13. Project B-610 instrument data base. Revision 6

    International Nuclear Information System (INIS)

    Silvan, G.R.

    1994-01-01

    The following technical information document contains the published data base listing for the instrumentation to be connected into the new MICON distributed control computer. Project B-610 PFP Instrument Upgrade (PFP HVAC Control Room Upgrade) will install the MICON system in PFP and provide for a new control room at the present site of the new SWP change room EDT-150750 1/11/93

  14. Predicting Agency Rating Migrations with Spread Implied Ratings

    OpenAIRE

    Jianming Kou; Dr Simone Varotto

    2005-01-01

    Investors traditionally rely on credit ratings to price debt instruments. However, rating agencies are known to be prudent in their approach to rating revisions, which results in delayed ratings adjustments to mutating credit conditions. For a large set of eurobonds we derive credit spread implied ratings and compare them with the ratings issued by rating agencies. Our results indicate that spread implied ratings often anticipate future movement of agency ratings and hence could help track cr...

  15. Comparison of two different methods for the determination of erythrocyte sedimentation rate

    Directory of Open Access Journals (Sweden)

    Gülfer Öztürk

    2014-09-01

    Full Text Available Objective: Erythrocyte Sedimentation Rate (ESR can be used for the follow-up of number of diseases. In recent years, closed automated systems that measure ESR directly from a capped EDTA and citrate blood sample tube have been developed. In this study, we aimed to compare and evaluate the consistence of assay results of iSed Alcor Auto-instrument and Berkhun SDM60 Auto-instrument. Methods: K2EDTA and citrated blood samples were taken from 149 randomly selected outpatients. The ESR of blood samples in tubes containing K2EDTA was determined by iSed Alcor Auto-instrument whereas Berkhun SDM60 Auto-instrument was used to determine the ESR of blood samples in tubes containing citrate. Results: The mean ± SD ESR was 24.48 ± 23.10 mm/hr (95% CI for the mean was 20.54–28.02 mm/hr for iSed Alcor Auto-instrument and 23.94 ± 17.24 mm/hr (95% CI for the mean was 21.15–26.73 mm/hr for the Berkhun Auto-instrument. We found the mean difference between two methods as 0.336 mm/hr (95% CI for the mean was −2.06 to 1.39 mm/hr; P = 0.701. The obtained correlation coefficient was 0.90 (P = 0.0001. There was no evidence of systemic bias, equal to 0.3 mm/hr (limits of agreement, –20.6 to 21.2 mm/hr. Conclusion: iSed Alcor Auto-instrument and Berkhun SDM60 Auto-instrument might be used as alternative systems each other. However, it should be monitored carefully in especially high ESR (>50 mm/hr results and the results should be checked according to the Westergren method. J Clin Exp Invest 2014; 5 (3: 371-375

  16. Field instrumentation for hydrofracturing stress measurements

    International Nuclear Information System (INIS)

    Bjarnason, Bjarni; Torikka, Arne.

    1989-08-01

    A recently developed system for rock stress measurements by the hydraulic fracturing method is documented in detail. The new equipment is intended for measurement in vertical or nearvertical boreholes, down to a maximum depth of 1000 m. The minimum borehole, diameter required is 56 mm. Downhole instrumentation comprises a straddle packer assembly for borehole fracturing, equipment for determination of fracture orientations and a pressure transducer. The downhole tools are operated by means of a multihose system, containing high pressure hydraulic tubings, signal cable and carrying wire into one hose unit. The surface components of the equipment include a system for generation and control of water pressures up to approximately 75 MPa, an hydraulically operated drum for the multihose and a data acquisition system. All surface instrumentation is permanently mounted on a truck, which also serves as power source for the instrumentation. In addition to the description of instrumentation, the theoretical fundament and the testing procedures associated with the hydraulic fracturing method are briefly outlined

  17. CAMEX-3 LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-3 Lightning Instrument Package (LIP) dataset contains electrical field measurements of lightning within storms studied during the Convection And Moisture...

  18. 26 CFR 1.1274-4 - Test rate.

    Science.gov (United States)

    2010-04-01

    ... applicable Federal rate for the debt instrument is a foreign currency rate of interest that is analogous to... test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in paragraph (a)(2) of this section, the test rate of interest for a debt instrument issued in consideration for...

  19. Reactor building pressure proof test (PPT) and leak rate test (LRT) of Qinshan phase III (CANDU) project

    International Nuclear Information System (INIS)

    Gu Jun; Shi Jinqi; Fan Fuping

    2004-12-01

    As the first reactor building (R/B) without stainless steel liner in china, TQNPC studied the containment characteristics, such as strong concrete absorb/release air effect, poor containment penetration. etc. And carefully prepared test scheme and emergency response, creatively introduced the instrument air self-supply system in reactor building, developed the special measurement and analysis system for PPT and LRT, organized work under high-pressure on large-scale in the test. Finally got the containment leak rate result and the test-cost-time value is the best in all same type tests. (authors)

  20. A preview of a microgravity laser light scattering instrument

    Science.gov (United States)

    Meyer, W. V.; Ansari, R. R.

    1991-01-01

    The development of a versatile, miniature, modular light scattering instrument to be used in microgravity is described. The instrument will measure microscopic particles in the size range of thirty angstroms to above three microns. This modular instrument permits several configurations, each optimized for a particular experiment. In particular, a multiangle instrument will probably be mounted in a rack in the Space Shuttle and on the Space Station. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations.

  1. Present status of ambient dose equivalent rate and radioactive substance concentration measurements in working environment. (3) Measuring instruments for ionizing radiation in working environments

    International Nuclear Information System (INIS)

    Matsubara, Shohei

    2006-01-01

    In order to measure the airborne radioactive substance concentration in working environments, some kinds of sampler such as dust sampler and iodine sampler, measuring instruments (alpha and beta spectrometer, and liquid scintillation counter), monitor (dust-, iodine- and gas-monitor), survey meter for measuring gamma ray dose rate are stated. The measurement method of α, β and γ-ray nuclides and ambient dose-equivalent at 10 mm was explained. Some examples of the list of dust sampler, filter, tritium sampler, dust monitor, iodine monitor, gas monitor, and survey meter on the market are shown. There are so many kinds of measuring instruments for ionizing radiation in working environment that the best instrument for measurement should be selected. The environment conditions such as sample form, temperature and humidity have to be considered in order to evaluate the measurement values. (S.Y.)

  2. Proceedings of the International topical meeting on VVER instrumentation and control

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The Proceedings contain the full texts of 44 contributions, out of which 42 have been input to INIS. The papers cover various aspects of WWER instrumentation and control including reactor upgrading and modernization, testing and refurbishment of instrumentation, and operational experience and problems. (A.K.).

  3. Proceedings of the International topical meeting on VVER instrumentation and control

    International Nuclear Information System (INIS)

    1997-11-01

    The Proceedings contain the full texts of 44 contributions, out of which 42 have been input to INIS. The papers cover various aspects of WWER instrumentation and control including reactor upgrading and modernization, testing and refurbishment of instrumentation, and operational experience and problems. (A.K.)

  4. Understanding High Rate Behavior Through Low Rate Analog

    Science.gov (United States)

    2014-04-28

    challenges in high rate character- isation of polymers. The most important is that, owing to their low stress wavespeed, the structural response of...box’ tool, to provide supporting date for the rate dependent mechanical character- isation . Experiments were performed on a TA instruments Q800

  5. Experimental study of the leakage rate through cracked reinforced concrete wall elements for defining the functional failure criteria of containment buildings

    International Nuclear Information System (INIS)

    Choun, Young Sun; Cho, Nam So

    2004-01-01

    Containment buildings in nuclear power plants should maintain their structural safety as well as their functional integrity during an operation period. To maintain the functional integrity, the wall and dome of the containment buildings have to maintain their air tightness under extreme loading conditions such as earthquakes, missile impact, and severe accidents. For evaluating the functional failure of containments, it is important to predict the leak amount through cracked concrete walls. The leakage through concrete cracks has been studied since 1972. Buss examined the flow rate of air through a pre-existing crack in a slab under air pressure. Rizkalla el al. initiated an experimental study for the leakage of prestressed concrete building segments under uniaxial and biaxial loadings to simulate the loading condition of containment buildings under an internal pressure. Recently, Salmon el al. initiated an experimental program for determining the leak rates in typical reinforced concrete shear walls subjected to beyond design basis earthquakes. This study investigates the cracking behavior of reinforced concrete containment wall elements under a uniaxial tension and addresses the outline of the leakage test for unlined containment wall elements

  6. Development and testing of an assessment instrument for the formative peer review of significant event analyses.

    Science.gov (United States)

    McKay, J; Murphy, D J; Bowie, P; Schmuck, M-L; Lough, M; Eva, K W

    2007-04-01

    To establish the content validity and specific aspects of reliability for an assessment instrument designed to provide formative feedback to general practitioners (GPs) on the quality of their written analysis of a significant event. Content validity was quantified by application of a content validity index. Reliability testing involved a nested design, with 5 cells, each containing 4 assessors, rating 20 unique significant event analysis (SEA) reports (10 each from experienced GPs and GPs in training) using the assessment instrument. The variance attributable to each identified variable in the study was established by analysis of variance. Generalisability theory was then used to investigate the instrument's ability to discriminate among SEA reports. Content validity was demonstrated with at least 8 of 10 experts endorsing all 10 items of the assessment instrument. The overall G coefficient for the instrument was moderate to good (G>0.70), indicating that the instrument can provide consistent information on the standard achieved by the SEA report. There was moderate inter-rater reliability (G>0.60) when four raters were used to judge the quality of the SEA. This study provides the first steps towards validating an instrument that can provide educational feedback to GPs on their analysis of significant events. The key area identified to improve instrument reliability is variation among peer assessors in their assessment of SEA reports. Further validity and reliability testing should be carried out to provide GPs, their appraisers and contractual bodies with a validated feedback instrument on this aspect of the general practice quality agenda.

  7. Alternative pathways to antimatter containment

    International Nuclear Information System (INIS)

    Rejcek, J.M.; Browder, M.K.; Fry, J.L.; Koymen, A.; Weiss, A.H.

    2003-01-01

    Antimatter containment is a gateway technology for future advancements in many areas. Immediate applications in propulsion, medicine, and instrumentation have already been envisioned and many others are yet to be considered. Key to this technological advance is identifying one or more pathways to achieve safe reliable containment of antimatter in sufficient quantities to be useful on an engineering and industrial scale. The goal of this paper is to review current approaches and discuss possible alternative pathways to antimatter containment. Specifically, this paper will address the possibility of designing a solid-state containment system that will safely hold antimatter in quantities dense enough to be of any engineering utility. A discussion of the current research, the needed engineering requirements, and a survey of current research is presented

  8. Operator/instrumentation interactions during the Three Mile Island incident

    International Nuclear Information System (INIS)

    Cummings, G.E.

    1979-10-01

    A discussion is presented of the operator/instrumentation interactions which had an effect on the course of the incident at the Three Mile Island-2 Nuclear Power Plant. A brief review of the sequence of occurrences at TMI-2 over the first 16 hours of the incident is given with particular emphasis on operator/instrumentation interactions. A breakdown of the six major items that seemed to have contributed to the characteristics of the incident is then given and also an outline of some of the currently proposed operator/instrumentation improvements. The six major items involve water level indication in the reactor, electromatic relief valve operation, auxiliary feed-water flow indication, containment isolation, extended range instrumentation, and computer readout

  9. Impact of state-of-the-art instrumentation on safety-related experimental studies proposed in containment studies facility (CSF)

    International Nuclear Information System (INIS)

    Gole, N.V.; Markandeya, S.G.; Subramaniam, K.; Ghosh, A.K.

    2002-01-01

    Full text: Conducting an experimental program for safety related studies for nuclear power plants (NPPs) is an extremely laborious and time-consuming task due to several reasons. Requirement for frequent replacements, testing and recalibration of a large number of instruments is one of them. Off-line analysis leading to identification of errors is another. A particular test may have to be abandoned based on such analysis. Following the rapid advances in instrumentation, a larger number of options are now available, which make experimentation easy. CSF is one of the upcoming facilities wherein deployment of state-of-the art became inevitable. This paper discusses in detail the design intent of instrumentation, the state-of-the-art instrumentation provisions made to fulfill it the overall impact of this on successful experimentation

  10. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  11. Smart integrated containment leakage rate test system using wireless communication

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hwan; Lee, Sang Yong; Kim, Jung Sun; Kim, Gun Soo; Kim, Jong Myeong; Ahn, Jong Han [Research and Development Center, Ulsan (Korea, Republic of)

    2012-10-15

    Integrated Leakage Rate Test (ILRT) is the important test the confidentiality and integrity of the containment building, which is the last barrier when Design basis accidents (DBA) of Nuclear Power plant occur. Since the result of this test is the basis to guarantee the safety of nuclear power plants, the test process, test procedure, and the test equipment are required to have high reliability. The test devices previously used have been products of VOLUMERTRICS and GRAFTEL of USA. These devices have been inconvenient to calibrate and use. Thus improved devices needed to be developed to remove the inconveniences, to verify the safety of Korean nuclear power plants with Korea's own technology, and to secure core technology. A new leak test system was developed by domestic technology for that purpose and needed to be verified. In this paper, technical details of the newly developed easy to use and highly reliable measuring test device, which is in operation at the nuclear power plant sites, will be introduced. State of art technology was applied to the device to address the shortcomings of previous US made devices and the difficulties to use on site.

  12. Containment/surveillance concepts for international safeguards in reprocessing plants

    International Nuclear Information System (INIS)

    Bleck, M.E.; Cameron, C.P.; Camp, A.L.

    1980-01-01

    This paper examines the potential role of advanced containment/surveillance instrumentation systems for international safeguards in reprocessing plants. Several conceptual systems for the surveillance of containment boundary penetrations in a reference reprocessing plant are described and evaluated. The results of the evaluation aid in understanding the potential capabilities and limitations of containment/surveillance as an international safeguards concept in this type of facility

  13. [work motivation -- assessment instruments and their relevance for medical care].

    Science.gov (United States)

    Fiedler, Rolf G; Ranft, Andreas; Greitemann, Bernhard; Heuft, Gereon

    2005-11-01

    The relevance of work motivation for medical research and healthcare, in particular rehabilitation, is described. Four diagnostic instruments in the German language are introduced which can assess work motivation using a scale system: AVEM, JDS, LMI and FBTM. Their possible application and potential usage for the clinical area are discussed. Apart from the FBTM, none of these instruments can be directly used as a general instrument in a normal medical clinical setting. Finally, a current model for work motivation (compensatory model of work motivation and volition) is presented that contains basis concepts, which are judged as important for future research questions concerning the development of motivation diagnostic instruments.

  14. Process instrument monitoring for SNM solution surveillance

    International Nuclear Information System (INIS)

    Armatys, C.M.; Johnson, C.E.; Wagner, E.P.

    1983-02-01

    A process monitoring computer system at the Idaho Chemical Processing Plant (ICPP) is being used to evaluate nuclear fuel reprocessing plant data for Safeguards surveillance capabilities. The computer system was installed to collect data from the existing plant instruments and to evaluate what safeguards assurances can be provided to complement conventional accountability and physical protection measures. Movements of solutions containing special nuclear material (SNM) can be observed, activities associated with accountancy measurements (mixing, sampling, and bulk measurement) can be confirmed, and long-term storage of SNM solutions can be monitored to ensure containment. Special precautions must be taken, both in system design and operation to ensure adequate coverage of essential measured parameters and interpretation of process data, which can be comprised by instrument malfunctions or failures, unreliable data collection, or process activities that deviate from readily identified procedures. Experience at ICPP and prior evaluations at the Tokai reprocessing plant show that the use of process data can provide assurances that accountability measurement procedures are followed and SNM solutions are properly contained and can help confirm that SNM controls are in effect within a facility

  15. Development of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    Science.gov (United States)

    Greene, Sally W; Olson, Beth H

    2008-09-01

    Breastfeeding rates remain low in the United States, especially among working women. Unfortunately, no quantitative instrument exists to facilitate the examination of why women who return to work discontinue breastfeeding sooner than the general population. The objective of this study was to develop an instrument to measure female employees' perceptions of breastfeeding support in the workplace, which would be suitable for piloting with the target population. Examination of the literature, reviews with experts, and one-on-one interviews with women who had experience combining breastfeeding and work were used to create the instrument subscales and items. Examination of the literature was used to develop four subscales: company policies/work culture, manager support, co-worker support, and workflow. Expert review resulted in the addition of a fifth subscale, the physical environment of the breastfeeding space. One-on-one interviews were used to ensure that the item wording was appropriate for the target population. Eighteen items were added, and 15 were reworded based on comments from the expert review and from the interviews. The resulting survey contained 54 items that required either categorical yes/no or Likert scale responses. Results from this process indicate the survey subscales and items adequately reflect women's perceptions of breastfeeding support in the workplace and the instrument is appropriate for piloting with new mother employees.

  16. Spatial overlap between environmental policy instruments and areas of high conservation value in forest.

    Science.gov (United States)

    Sverdrup-Thygeson, Anne; Søgaard, Gunnhild; Rusch, Graciela M; Barton, David N

    2014-01-01

    In order to safeguard biodiversity in forest we need to know how forest policy instruments work. Here we use a nationwide network of 9400 plots in productive forest to analyze to what extent large-scale policy instruments, individually and together, target forest of high conservation value in Norway. We studied both instruments working through direct regulation; Strict Protection and Landscape Protection, and instruments working through management planning and voluntary schemes of forest certification; Wilderness Area and Mountain Forest. As forest of high conservation value (HCV-forest) we considered the extent of 12 Biodiversity Habitats and the extent of Old-Age Forest. We found that 22% of productive forest area contained Biodiversity Habitats. More than 70% of this area was not covered by any large-scale instruments. Mountain Forest covered 23%, while Strict Protection and Wilderness both covered 5% of the Biodiversity Habitat area. A total of 9% of productive forest area contained Old-Age Forest, and the relative coverage of the four instruments was similar as for Biodiversity Habitats. For all instruments, except Landscape Protection, the targeted areas contained significantly higher proportions of HCV-forest than areas not targeted by these instruments. Areas targeted by Strict Protection had higher proportions of HCV-forest than areas targeted by other instruments, except for areas targeted by Wilderness Area which showed similar proportions of Biodiversity Habitats. There was a substantial amount of spatial overlap between the policy tools, but no incremental conservation effect of overlapping instruments in terms of contributing to higher percentages of targeted HCV-forest. Our results reveal that although the current policy mix has an above average representation of forest of high conservation value, the targeting efficiency in terms of area overlap is limited. There is a need to improve forest conservation and a potential to cover this need by better

  17. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  18. A Comparison of the McMaster and Circumplex Family Assessment Instruments.

    Science.gov (United States)

    Fristad, Mary A.

    1989-01-01

    Compared clinical rating scales and self-report scales from McMaster and Circumplex models of family functioning with families (N=41). Found McMaster instruments had superior sensitivity; greater correspondence between clinical rating scales and family member self-report inventories on McMaster instruments; and lack of support for the curvilinear…

  19. High-Level Disinfection of Otorhinolaryngology Clinical Instruments: An Evaluation of the Efficacy and Cost-effectiveness of Instrument Storage.

    Science.gov (United States)

    Yalamanchi, Pratyusha; Yu, Jason; Chandler, Laura; Mirza, Natasha

    2018-01-01

    Objectives Despite increasing interest in individual instrument storage, risk of bacterial cross-contamination of otorhinolaryngology clinic instruments has not been assessed. This study is the first to determine the clinical efficacy and cost-effectiveness of standard high-level disinfection and clinic instrument storage. Methods To assess for cross-contamination, surveillance cultures of otorhinolaryngology clinic instruments subject to standard high-level disinfection and storage were obtained at the start and end of the outpatient clinical workday. Rate of microorganism recovery was compared with cultures of instruments stored in individual peel packs and control cultures of contaminated instruments. Based on historical clinic data, the direct allocation method of cost accounting was used to determine aggregate raw material cost and additional labor hours required to process and restock peel-packed instruments. Results Among 150 cultures of standard high-level disinfected and co-located clinic instruments, 3 positive bacterial cultures occurred; 100% of control cultures were positive for bacterial species ( P cost of individual semicritical instrument storage at $97,852.50 per year. Discussion With in vitro inoculation of >200 otorhinolaryngology clinic instruments, this study demonstrates that standard high-level disinfection and storage are equally efficacious to more time-consuming and expensive individual instrument storage protocols, such as peel packing, with regard to bacterial contamination. Implications for Practice Standard high-level disinfection and storage are equally effective to labor-intensive and costly individual instrument storage protocols.

  20. Virtual Instrument for Determining Rate Constant of Second-Order Reaction by pX Based on LabVIEW 8.0.

    Science.gov (United States)

    Meng, Hu; Li, Jiang-Yuan; Tang, Yong-Huai

    2009-01-01

    The virtual instrument system based on LabVIEW 8.0 for ion analyzer which can measure and analyze ion concentrations in solution is developed and comprises homemade conditioning circuit, data acquiring board, and computer. It can calibrate slope, temperature, and positioning automatically. When applied to determine the reaction rate constant by pX, it achieved live acquiring, real-time displaying, automatical processing of testing data, generating the report of results; and other functions. This method simplifies the experimental operation greatly, avoids complicated procedures of manual processing data and personal error, and improves veracity and repeatability of the experiment results.

  1. 26 CFR 1.1275-6 - Integration of qualifying debt instruments.

    Science.gov (United States)

    2010-04-01

    ... § 1.483-4 or § 1.1275-4(c) (certain contingent payment debt instruments issued for nonpublicly traded... the qualifying debt instrument. A financial instrument that hedges currency risk is not a § 1.1275-6... denominated in pounds, the swap hedges only interest rate risk, not currency risk. Therefore, the transaction...

  2. Real-time synchronous measurement of curing characteristics and polymerization stress in bone cements with a cantilever-beam based instrument

    Science.gov (United States)

    Palagummi, Sri Vikram; Landis, Forrest A.; Chiang, Martin Y. M.

    2018-03-01

    An instrumentation capable of simultaneously determining degree of conversion (DC), polymerization stress (PS), and polymerization exotherm (PE) in real time was introduced to self-curing bone cements. This comprises the combination of an in situ high-speed near-infrared spectrometer, a cantilever-beam instrument with compliance-variable feature, and a microprobe thermocouple. Two polymethylmethacrylate-based commercial bone cements, containing essentially the same raw materials but differ in their viscosity for orthopedic applications, were used to demonstrate the applicability of the instrumentation. The results show that for both the cements studied the final DC was marginally different, the final PS was different at the low compliance, the peak of the PE was similar, and their polymerization rates were significantly different. Systematic variation of instrumental compliance for testing reveals differences in the characteristics of PS profiles of both the cements. This emphasizes the importance of instrumental compliance in obtaining an accurate understanding of PS evaluation. Finally, the key advantage for the simultaneous measurements is that these polymerization properties can be correlated directly, thus providing higher measurement confidence and enables a more in-depth understanding of the network formation process.

  3. Identifying developmental coordination disorder : MOQ-T validity as a fast screening instrument based on teachers' ratings and its relationship with praxic and visuospatial working memory deficits

    NARCIS (Netherlands)

    Giofre, David; Cornoldi, Cesare; Schoemaker, Marina M.

    2014-01-01

    The present study was devoted to test the validity, of the Italian adaptation of the Motor Observation Questionnaire for Teachers (MOQ-T, Schoemaker, Flapper, Reinders-Messelink, & De Kloet, 2008) as a fast screening instrument, based on teachers' ratings, for detecting developmental coordination

  4. Instrumentation and operational plan for geokinetics retort No. 22

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, R.L.; Hommert, P.J.

    1980-04-01

    This report outlines the general plan for the instrumentation and technical direction of a horizontal in siti retorting experiment to be conducted at the Geokinetics, Inc. field site in Uintah County, Utah. Bed preparation has been accomplished by Geokinetics by blasting the retort zone with explosives emplaced in wells drilled from the surface. Downhole instrumentation will consist of approx. 300 thermocouples and 28 combustion gas sampling ports to monitor the movement of the reaction front during the retorting process. Surface instrumentation will provide measurements of flow rates, gas composition, liquid products and other process parameters to monitor the overall operation of the process. The operational plan includes provision for data interpretation and real time material balance calculations in the field, including an evaluation of the effect on processing rates and oil yield due to the use of recycled combusted off gases and changes in rate of injection of inlet gases.

  5. A Counselor's Guide to Career Assessment Instruments, Sixth Edition

    Science.gov (United States)

    Wood, Chris; Hays, Danica G.

    2013-01-01

    This book contains exemplary resources for counselors, career development facilitators, school counselors, and other career professionals working in a variety of settings. This edition is an essential guide to career assessment and contains a comprehensive list of career assessment instruments. It has over 70 reviews and includes…

  6. 3rd Symposium on Space Optical Instruments and Applications

    CERN Document Server

    Zhang, Guangjun

    2017-01-01

    This volume contains selected and expanded contributions presented at the 3rd Symposium on Space Optical Instruments and Applications in Beijing, China June 28 – 29, 2016. This conference series is organised by the Sino-Holland Space Optical Instruments Laboratory, a cooperation platform between China and the Netherlands. The symposium focused on key technological problems of optical instruments and their applications in a space context. It covered the latest developments, experiments and results regarding theory, instrumentation and applications in space optics. The book is split across five topical sections. The first section covers space optical remote sensing system design, the second advanced optical system design, the third remote sensor calibration and measurement. Remote sensing data processing and information extraction is then presented, followed by a final section on remote sensing data applications. .

  7. ExoMars Trace Gas Orbiter Instrument Modelling Approach to Streamline Science Operations

    Science.gov (United States)

    Munoz Fernandez, Michela; Frew, David; Ashman, Michael; Cardesin Moinelo, Alejandro; Garcia Beteta, Juan Jose; Geiger, Bernhard; Metcalfe, Leo; Nespoli, Federico; Muniz Solaz, Carlos

    2018-05-01

    ExoMars Trace Gas Orbiter (TGO) science operations activities are centralised at ESAC's Science Operations Centre (SOC). The SOC receives the inputs from the principal investigators (PIs) in order to implement and deliver the spacecraft pointing requests and instrument timelines to the Mission Operations Centre (MOC). The high number of orbits per planning cycle has made it necessary to abstract the planning interactions between the SOC and the PI teams at the observation level. This paper describes the modelling approach we have conducted for TGOís instruments to streamline science operations. We have created dynamic observation types that scale to adapt to the conditions specified by the PI teams including observation timing, and pointing block parameters calculated from observation geometry. This approach is considered and improvement with respect to previous missions where the generation of the observation pointing and commanding requests was performed manually by the instrument teams. Automation software assists us to effectively handle the high density of planned orbits with increasing volume of scientific data and to successfully meet opportunistic scientific goals and objectives. Our planning tool combines the instrument observation definition files provided by the PIs together with the flight dynamics products to generate the Pointing Requests and the instrument timeline (ITL). The ITL contains all the validated commands at the TC sequence level and computes the resource envelopes (data rate, power, data volume) within the constraints. At the SOC, our main goal is to maximise the science output while minimising the number of iterations among the teams, ensuring that the timeline does not violate the state transitions allowed in the Mission Operations Rules and Constraints Document.

  8. Experimental verification of methods for gamma dose rate calculations in the vicinity of containers with the RA reactor spent fuel elements

    International Nuclear Information System (INIS)

    Milosevic, M.; Cupac, S.; Pesic, M.

    2005-01-01

    The methodology for equivalent gamma dose rate determination on the outer surface of existing containers with the spent fuel elements of the RA reactor is briefly summarised, and experimental verification of this methodology in the field of gamma rays near the aluminium channel with spent fuel elements lifted from the stainless steel containers no. 275 in the RA reactor hall is presented. The proposed methodology is founded on: the existing fuel burnup data base; methods and models for the photon source determination in the RA reactor spent fuel elements developed in the Vinca Institute, and validated Monte Carlo codes for the equivalent gamma dose rate calculations. (author) [sr

  9. A proposed structural, risk-informed approach to the periodicity of CANDU-6 nuclear containment integrated leak rate testing

    Energy Technology Data Exchange (ETDEWEB)

    Saliba, N. [McGill Univ., Dept. of Civil Engineering and Applied Mechanics, Montreal, Quebec (Canada); Komljenovic, D. [Hydro-Quebec, Gentilly-2 Nuclear Power Plant, Becancour, Quebec (Canada); Chouinard, L. [McGill Univ., Dept. of Civil Engineering and Applied Mechanics, Montreal, Quebec (Canada); Vaillancourt, R.; Chretien, G. [Hydro-Quebec, Gentilly-2 Nuclear Power Plant, Becancour, Quebec (Canada); Gocevski, V. [Hydro-Quebec Equipements, Montreal, Quebec (Canada)

    2010-07-01

    As ultimate lines of defense against leakage of large amounts of radioactive material to the environment in case of major reactor accidents, containments have been monitored through well designed periodic tests to ensure their proper performance. Regulatory organizations have imposed types and frequencies of containment tests based on highly-conservative deterministic approaches, and judgments of knowledgeable experts. Recent developments in the perception and methods of risk evaluation have been applied to rationalize the leakage-rate testing frequencies while maintaining risks within acceptable levels, preserving the integrity of containments, and respecting the defense-in-depth philosophy. The objective of this paper is to introduce a proposed risk-informed decision making framework on the periodicity of nuclear containment ILRTs for CANDU-6 nuclear power plants based on five main decision criteria, namely: 1) the containment structural integrity; 2) inputs from PSA Level-2; 3) the requirements of deterministic safety analyses and defense-in-depth concepts; 4- the obligations under regulatory and standard requirements; and 5) the return of experience from nuclear containments historic performance. The concepts of dormant reliability and structural fragility will guide the assessment of the containment structural integrity, within the general context of a global containment life cycle management program. This study is oriented towards the requirements of CANDU-6 reactors, in general, and Hydro-Quebec's Gentilly-2 nuclear power plant, in particular. The present article is the first part in a series of papers that will comprehensively detail the proposed research. (author)

  10. A proposed structural, risk-informed approach to the periodicity of CANDU-6 nuclear containment integrated leak rate testing

    International Nuclear Information System (INIS)

    Saliba, N.; Komljenovic, D.; Chouinard, L.; Vaillancourt, R.; Chretien, G.; Gocevski, V.

    2010-01-01

    As ultimate lines of defense against leakage of large amounts of radioactive material to the environment in case of major reactor accidents, containments have been monitored through well designed periodic tests to ensure their proper performance. Regulatory organizations have imposed types and frequencies of containment tests based on highly-conservative deterministic approaches, and judgments of knowledgeable experts. Recent developments in the perception and methods of risk evaluation have been applied to rationalize the leakage-rate testing frequencies while maintaining risks within acceptable levels, preserving the integrity of containments, and respecting the defense-in-depth philosophy. The objective of this paper is to introduce a proposed risk-informed decision making framework on the periodicity of nuclear containment ILRTs for CANDU-6 nuclear power plants based on five main decision criteria, namely: 1) the containment structural integrity; 2) inputs from PSA Level-2; 3) the requirements of deterministic safety analyses and defense-in-depth concepts; 4- the obligations under regulatory and standard requirements; and 5) the return of experience from nuclear containments historic performance. The concepts of dormant reliability and structural fragility will guide the assessment of the containment structural integrity, within the general context of a global containment life cycle management program. This study is oriented towards the requirements of CANDU-6 reactors, in general, and Hydro-Quebec's Gentilly-2 nuclear power plant, in particular. The present article is the first part in a series of papers that will comprehensively detail the proposed research. (author)

  11. Calculation of mean outcrossing rates of non-Gaussian processes with stochastic input parameters - Reliability of containers stowed on ships in severe sea

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2010-01-01

    values is expected to occur, and the final result, the mean outcrossing rate, is obtained by summation. The derived procedure is illustrated by an example considering the forces in containers stowed on ships and, in particular, results are presented for the so-called racking failure in the containers...

  12. Instrument for measuring fuel cladding strain

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1976-01-01

    Development work to provide instrumentation for the continuous measurement of strain of material specimens such as nuclear fuel cladding has shown that a microwave sensor and associated instrumentation hold promise. The cylindrical sensor body enclosing the specimen results in a coaxial resonator absorbing microwave energy at frequencies dependent upon the diameter of the specimen. Diametral changes of a microinch can be resolved with use of the instrumentation. Very reasonable values of elastic strain were measured at 75 0 F and 1000 0 F for an internally pressurized 20 percent C.W. 316 stainless steel specimen simulating nuclear fuel cladding. The instrument also indicated the creep strain of the same specimen pressurized at 6500 psi and at a temperature of 1000 0 F for a period of 700 hours. Although the indicated strain appears greater than actual, the sensor/specimen unit experienced considerable oxidation even though an inert gas purge persisted throughout the test duration. By monitoring at least two modes of resonance, the measured strain was shown to be nearly independent of sensor temperature. To prevent oxidation, a second test was performed in which the specimen/sensor units were contained in an evacuated enclosure. The strain of the two prepressurized specimens as indicated by the microwave instrumentation agreed very closely with pre- and post-test measurements obtained with use of a laser interferometer

  13. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    International Nuclear Information System (INIS)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added

  14. Design aspects of safety critical instrumentation of nuclear installations

    Energy Technology Data Exchange (ETDEWEB)

    Swaminathan, P. [Electronics Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu (India)]. E-mail: swamy@igcar.ernet.in

    2005-07-01

    Safety critical instrumentation systems ensure safe shutdown/configuration of the nuclear installation when process status exceeds the safety threshold limits. Design requirements for safety critical instrumentation such as functional and electrical independence, fail-safe design, and architecture to ensure the specified unsafe failure rate and safe failure rate, human machine interface (HMI), etc., are explained with examples. Different fault tolerant architectures like 1/2, 2/2, 2/3 hot stand-by are compared for safety critical instrumentation. For embedded systems, software quality assurance is detailed both during design phase and O and M phase. Different software development models such as waterfall model and spiral model are explained with examples. The error distribution in embedded system is detailed. The usage of formal method is outlined to reduce the specification error. The guidelines for coding of application software are outlined. The interface problems of safety critical instrumentation with sensors, actuators, other computer systems, etc., are detailed with examples. Testability and maintainability shall be taken into account during design phase. Online diagnostics for safety critical instrumentation is detailed with examples. Salient details of design guides from Atomic Energy Regulatory Board, International Atomic Energy Agency and standards from IEEE, BIS are given towards the design of safety critical instrumentation systems. (author)

  15. Design aspects of safety critical instrumentation of nuclear installations

    International Nuclear Information System (INIS)

    Swaminathan, P.

    2005-01-01

    Safety critical instrumentation systems ensure safe shutdown/configuration of the nuclear installation when process status exceeds the safety threshold limits. Design requirements for safety critical instrumentation such as functional and electrical independence, fail-safe design, and architecture to ensure the specified unsafe failure rate and safe failure rate, human machine interface (HMI), etc., are explained with examples. Different fault tolerant architectures like 1/2, 2/2, 2/3 hot stand-by are compared for safety critical instrumentation. For embedded systems, software quality assurance is detailed both during design phase and O and M phase. Different software development models such as waterfall model and spiral model are explained with examples. The error distribution in embedded system is detailed. The usage of formal method is outlined to reduce the specification error. The guidelines for coding of application software are outlined. The interface problems of safety critical instrumentation with sensors, actuators, other computer systems, etc., are detailed with examples. Testability and maintainability shall be taken into account during design phase. Online diagnostics for safety critical instrumentation is detailed with examples. Salient details of design guides from Atomic Energy Regulatory Board, International Atomic Energy Agency and standards from IEEE, BIS are given towards the design of safety critical instrumentation systems. (author)

  16. 26 CFR 1.508-3 - Governing instruments.

    Science.gov (United States)

    2010-04-01

    ... foundation shall not be exempt from taxation under section 501(a) for a taxable year unless by the end of... described in section 4947(a)) that its governing instrument contains no mandatory directions which conflict...(e), such organization will not be exempt from taxation. (6) Retroactive application to grants or...

  17. 24 CFR 107.25 - Provisions in legal instruments.

    Science.gov (United States)

    2010-04-01

    ... Provisions in legal instruments. (a) The following documents shall contain provisions or statements requiring...) Approvals of financial institutions and other lenders as approved FHA mortgagees, (5) Requests for subdivision reports under home mortgage procedures and for preapplication analysis of multifamily and land...

  18. Assessing information needs and instrument availability for a pressurized water reactor during severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Duane J. (Idaho National Engineering Laboratory, Idaho Falls, ID 83415 (United States)); Arcieri, William C. (Idaho National Engineering Laboratory, Idaho Falls, ID 83415 (United States)); Ward, Leonard W. (Idaho National Engineering Laboratory, Idaho Falls, ID 83415 (United States))

    1994-07-01

    A five-step methodology was developed to evaluate information needs for nuclear power plants under accident conditions and the availability of plant instrumentation during severe accidents. Step 1 examines the credible accidents and their relationships to plant safety functions. Step 2 determines the information that personnel involved in accident management will need to understand plant behavior. Step 3 determines the capability of the instrumentation to function properly under severe accident conditions. Step 4 determines the conditions expected during the identified severe accidents. Step 5 compares the instrument capabilities and severe accident conditions, to evaluate the availability of the instrumentation to supply needed plant information. This methodology was applied to a pressurized water reactor with a large dry containment and the results are presented. A companion article describes application of the methodology to a boiling water reactor with a Mark I containment. ((orig.))

  19. Assessing information needs and instrument availability for a pressurized water reactor during severe accidents

    International Nuclear Information System (INIS)

    Hanson, Duane J.; Arcieri, William C.; Ward, Leonard W.

    1994-01-01

    A five-step methodology was developed to evaluate information needs for nuclear power plants under accident conditions and the availability of plant instrumentation during severe accidents. Step 1 examines the credible accidents and their relationships to plant safety functions. Step 2 determines the information that personnel involved in accident management will need to understand plant behavior. Step 3 determines the capability of the instrumentation to function properly under severe accident conditions. Step 4 determines the conditions expected during the identified severe accidents. Step 5 compares the instrument capabilities and severe accident conditions, to evaluate the availability of the instrumentation to supply needed plant information. This methodology was applied to a pressurized water reactor with a large dry containment and the results are presented. A companion article describes application of the methodology to a boiling water reactor with a Mark I containment. ((orig.))

  20. Exploring the relationships among performance-based functional ability, self-rated disability, perceived instrumental support, and depression: a structural equation model analysis.

    Science.gov (United States)

    Weil, Joyce; Hutchinson, Susan R; Traxler, Karen

    2014-11-01

    Data from the Women's Health and Aging Study were used to test a model of factors explaining depressive symptomology. The primary purpose of the study was to explore the association between performance-based measures of functional ability and depression and to examine the role of self-rated physical difficulties and perceived instrumental support in mediating the relationship between performance-based functioning and depression. The inclusion of performance-based measures allows for the testing of functional ability as a clinical precursor to disability and depression: a critical, but rarely examined, association in the disablement process. Structural equation modeling supported the overall fit of the model and found an indirect relationship between performance-based functioning and depression, with perceived physical difficulties serving as a significant mediator. Our results highlight the complementary nature of performance-based and self-rated measures and the importance of including perception of self-rated physical difficulties when examining depression in older persons. © The Author(s) 2014.

  1. Flight Test Guide (Part 61 Revised): Instrument Pilot: Helicopter.

    Science.gov (United States)

    Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.

    The guide provides an outline of the skills required to pass the flight test for an Instrument Pilot Helicopter Rating under Part 61 (revised) of Federal Aviation Regulations. General procedures for flight tests are described and the following pilot operations outlined: maneuvering by reference to instruments, IFR navigation, instrument…

  2. Information needs and instrument availability for accident management : Application to YGN 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Whan; Park, Rae Jun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Suh, Kune Yull [Seoul Nationsl University, Seoul (Korea, Republic of)

    1996-12-01

    This paper introduces the five-step methodology for identifying information needs and assessing instrument availability during the course of severe in nuclear power plants. The methodology is applied to the Yonggwang (YGN) 3 and 4 to shed light on accident management. It constructs three safety objective trees to prevent the reactor vessel failure, to prevent the containment failure, and to mitigate the fission product release from the containment. The study assesses information needs and instrument availability under severe conditions for preventing the reactor vessel failure of YGN 3 and 4, and recommends additional instruments that may prove to be vital importance in managing the accident. 6 refs., 6 figs., 3 tabs. (author).

  3. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  4. Informal caregiving in COPD: A systematic review of instruments and their measurement properties.

    Science.gov (United States)

    Cruz, Joana; Marques, Alda; Machado, Ana; O'Hoski, Sachi; Goldstein, Roger; Brooks, Dina

    2017-07-01

    Increasing symptoms and activity restriction associated with COPD progression greatly impact on the lives of their informal caregivers, who play a vital role in maintaining their health. An understanding of this impact is important for clinicians to support caregivers and maintain a viable patient environment at home. This systematic review aimed to identify the instruments commonly used to assess informal caregiving in COPD and describe their measurement properties in this population. Searches were conducted in PubMed, Scopus, Web of Science, CINAHL and PsycINFO and in references of key articles, until November 2016 (PROSPERO: CRD42016041401). Instruments used to assess the impact of COPD on caregivers were identified and their properties described. Quality of studies was rated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Quality of the measurement properties of instruments was rated as 'positive', 'negative' or 'indeterminate'. Patients cared for, had moderate to very severe COPD and the sample of caregivers ranged from 24 to 406. Thirty-five instruments were used in fifty studies to assess caregivers' psychological status and mood (9 instruments), burden/distress (12 instruments), quality of life (5 instruments) or other (9 instruments). Eighteen studies assessed the measurement properties of 21 instruments, most commonly hypothesis testing (known validity) and internal consistency. Study quality varied from 'poor' to 'fair' and with many properties rated as 'indeterminate'. Although several instruments have been used to assess the impact of COPD on caregivers, an increased understanding of their properties is needed before their widespread implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Workshop on Advanced Technologies for Planetary Instruments, part 1

    International Nuclear Information System (INIS)

    Appleby, J.F.

    1993-01-01

    This meeting was conceived in response to new challenges facing NASA's robotic solar system exploration program. This volume contains papers presented at the Workshop on Advanced Technologies for Planetary Instruments on 28-30 Apr. 1993. This meeting was conceived in response to new challenges facing NASA's robotic solar system exploration program. Over the past several years, SDIO has sponsored a significant technology development program aimed, in part, at the production of instruments with these characteristics. This workshop provided an opportunity for specialists from the planetary science and DOD communities to establish contacts, to explore common technical ground in an open forum, and more specifically, to discuss the applicability of SDIO's technology base to planetary science instruments

  6. Application of Instrumented Charpy Method in Characterisation of Materials

    Directory of Open Access Journals (Sweden)

    Željko Alar

    2015-07-01

    Full Text Available Testing of absorbed impact energy according to the Charpy method is carried out to determine the behaviour of a material under the impact load. Instrumented Charpy method allows getting the force displacement curve through the entire test, That curve can be related to force-displacement curve which is obtained by the static tensile test. The purpose of this study was to compare the results of forces obtained by the static tensile test with the forces obtained by the instrumented Charpy method. Experimental part of the work contains testing of the mechanical properties of S275J0 steel by the static tensile test and Impact test on instrumented Charpy pendulum.

  7. Climate protection after Copenhagen. International instruments and national implementation. Proceedings; Klimaschutz nach Kopenhagen. Internationale Instrumente und nationale Umsetzung. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    Gundel, Joerg; Lange, Knut Werner (eds.)

    2011-07-01

    The publication contains the results of the First Bayreuth Energy Law Days on the subject of 'Climate Protection after Copenhagen'. Following the UN climate conference of December 2009, it presents the current state of discussion of the legal instruments of climate protection on an international, European and national level. (orig./RHM)

  8. Development of ultrasonic instrument 'UT1000 Series'

    International Nuclear Information System (INIS)

    Ogura, Yukio; Ikeda, Toshimichi

    1984-01-01

    The ultrasonic flaw detectors with 'A-scope indication' have been frequently used as the means for confirming the soundness of structures and equipments, but there are problems in their operational, quantifying and recording capabilities. Recently, the digital ultrasonic measuring instrument of touch panel type ''UT 1000 Series'' has been developed, which resolves these problems by a single effort. This measuring instrument is that of portable type, which gives the digital output of measured results in real time only by lightly touching the peak point of an echo on the Brown tube. This instrument contains the rich software for measurement, and can measure the positions and dimensions of defects and the pressure on contact surfaces with high accuracy. 'A-scope indication' is the indication with an oscilloscope taking the intensity of echo and the propagation time of ultrasonic waves on the ordinate and abscissa, respectively. There are three types of the instrument, that is, for detecting defects, for measuring contact surface pressure and for both purposes. The size of the instrument is 240 mm width, 350 mm length and 175 mm height, and the weight is 8.5 kgf. The specification, function and features of the ultrasonic flaw detector, touch panel, gain setter, key board, microcomputer and others are reported. (Kako, I.)

  9. Development of a versatile laser light scattering instrument

    Science.gov (United States)

    Meyer, William V.; Ansari, Rafat R.

    1990-10-01

    A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.

  10. Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator

    International Nuclear Information System (INIS)

    2002-01-01

    This practice outlines dosimetric procedures to be followed with self-contained dry-storage gamma-ray irradiators. If followed, these procedures will help to ensure that calibration and testing will be carried out with acceptable precision and accuracy and that the samples processed with ionizing radiation from gamma rays in a self-contained dry-storage irradiator receive absorbed doses within a predetermined range. This practice covers dosimetry in the use of dry-storage gamma-ray irradiators, namely self-contained dry storage 137 Cs or 60 Co irradiators (shielded free-standing irradiators). It does not cover underwater pool sources, panoramic gamma-ray sources such as those raised mechanically or pneumatically to irradiate isotropically into a room or through a collimator, nor does it cover self-contained bremsstrahlung x-ray units. The absorbed dose range for the use of the dry-storage self-contained gamma-ray irradiators covered by this practice is typically 1 to 10 5 Gy, depending on the application. The absorbed-dose rate range typically is from 10 -2 to 10 3 Gy/min. This practice describes general procedures applicable to all self-contained dry-storage gamma-ray irradiators. For procedures specific to dosimetry in blood irradiation, see ISO/ ASTM Practice 51939. For procedures specific to dosimetry in radiation research on food and agricultural products, see ISO/ASTM Practice 51900. For procedures specific to radiation hardness testing, see ASTM Practice E 1249. For procedures specific to the dosimetry in the irradiation of insects for sterile release programs, see ISO/ASTM Guide 51940. In those cases covered by ISO/ASTM Practices 51939, 51900, 51940, or ASTM E 1249, those standards take precedence. In addition, this practice does not cover absorbed-dose rate calibrations of radiation protection instrumentation

  11. Depression and anxiety in patients with coronary artery disease, measured by means of self-report measures and clinician-rated instrument.

    Science.gov (United States)

    Moryś, Joanna M; Bellwon, Jerzy; Adamczyk, Katarzyna; Gruchała, Marcin

    2016-01-01

    The presence of depression symptomatology significantly deteriorates the prognosis for the patient. There are many instruments developed to measure depression and anxiety in clinical trials; however, the suitability of the specific scale for screening these disorders in cardiovascular patients is debatable. The aim of current study is to verify which of the major assessment instruments is the most relevant for the screening evaluation of depression and anxiety in patients with cardiovascular system diseases. The sample studied consisted of 120 patients with stable coronary artery disease (CAD). They did not display serious psychiatric or somatic disorders. To assess depressive and anxiety symptoms we used self-reporting measures (BDI-II, HADS, SSAI/STAI, and PHQ), the results of which were compared to results obtained on the basis of a clinician-rating instrument (HRSD). We found that depressive symptoms assessed on the basis of HRSD, BDI-II, and PHQ-9 were equivalent in results, while the results obtained in HADS-D were significantly lower. Anxiety symptoms were found at approximate levels in HADS, SSAI, and GAD-7. The assessment of somatic symptoms in patients with CAD indicates that 87.5% of the subjects reported somatic symptoms of various intensity. Screening assessment of depression in patients with CAD gives different results depending on the tool used. We found that HADS significantly underestimates the percentage of patients with symptoms of depression in patients with CAD. Assessing anxiety symptoms with the aid of HADS gave outcomes close to the results gained by use of other tools.

  12. Conference on instrumental activation analysis - IAA 89

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1989-05-01

    The proceedings contain 40 abstracts of papers all of which have been incorporated in INIS. The papers were centred on the applications of radioanalytical methods, especialy on neutron activation analysis, X-ray fluorescence analysis, PIXE analysis and tracer techniques in biology, medicine and metallurgy, measuring instruments including microcomputers, and data processing methods. (J.P.)

  13. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  14. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  15. Money market rates and implied CCAPM rates: some international evidence

    OpenAIRE

    Yamin Ahmad

    2004-01-01

    New Neoclassical Synthesis models equate the instrument of monetary policy to the implied CCAPM rate arising from an Euler equation. This paper identifies monetary policy shocks within six of the G7 countries and examines the movement of money market and implied CCAPM rates. The key result is that an increase in the nominal interest rate leads to a fall in the implied CCAPM rate. Incorporating habit still yields the same result. The findings suggest that the movement of these two rates implie...

  16. Characterization of the Geosynchronous Plasma Environment for the SENSER/RROE Optical Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Woodroffe, Jesse Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-11-08

    In this report, we summarize available research in order to characterize expected rates of particle incidence on the SENSER/RROE optical instrument. We first investigate the “normal” background levels using data from statistical studies of spacecraft in geosynchronous orbit and empirical models. We then consider “worst case” scenarios based on event studies in which extreme fluxes have been observed. We use these data to define “maximum” rates of particle incidence. We then consider how incident particles will actually produce counts in the instrument by considering the effects of screening by the instrument housing and the possibility of direct particle access to the housing, with rates for both primary access and secondary electron generation.

  17. The Impact of Cooling Rate on the Safety of Food Products as Affected by Food Containers

    DEFF Research Database (Denmark)

    Coorey, Ranil; Ng, Denise Sze Hu; Jayamanne, Vijith S.

    2018-01-01

    In recent decades, the demand for ready‐to‐eat (RTE) food items prepared by the food catering sector has increased together with the value of cook‐serve, cook‐chill, and cook‐freeze food products. The technologies by which foods are cooked, chilled, refrigerated for storage, and reheated before...... serving are of prime importance to maintain safety. Packaging materials and food containers play an important role in influencing the cooling rate of RTE foods. Food items that are prepared using improper technologies and inappropriate packaging materials may be contaminated with foodborne pathogens....... Numerous research studies have shown the impact of deficient cooling technologies on the survival and growth of foodborne pathogens, which may subsequently pose a threat to public health. The operating temperatures and cooling rates of the cooling techniques applied must be appropriate to inhibit...

  18. Instruments to assess stigmatization in dermatology.

    Science.gov (United States)

    Dimitrov, Dimitre; Szepietowski, Jacek C

    2017-11-03

    Stigmatization is the assignment of negative perceptions to an individual because of a perceived difference from the population at large. Skin conditions are frequently the reason of social rejection with a consequent negative influence on the personal and social life of patients. The aim of the current study was to review the available instruments that can be successfully utilized to measure the stigmatization level among dermatological patients. We performed our search on PubMed up to November 2016 and utilized combinations of key phrases containing such words as stigmatization, skin, dermatology, names of various skin conditions (psoriasis, vitiligo, acne, etc.), measurement. The search found a considerable number of articles - 548. After filtering them through a precise selection process, 58 articles remained. We concentrated only on the methodological aspects to assess stigmatization in various dermatoses. The review ascertained that there exist numerous instruments in the form of questionnaires. They were utilized in various researches in order to assess the stigmatization level in patients with skin problems. We divided them into two main groups: dermatology specific instruments (6 questionnaires) and dermatosis/disease specific ones (8 questionnaires). It is recommended to use dermatology-specific instruments to compare the stigmatization level in various skin conditions. They can be utilized as well as a first line tools to study the feeling of stigmatization in specific skin diseases; however, where it is possible, they should be supplemented with the disease-specific instrument for deeper analysis of both qualities of life and stigmatization.

  19. In-depth analysis of eight criteria for integrated leakage rate tests for nuclear power plant containment buildings

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.F.; Lurie, D.

    1989-01-01

    A U.S. Nuclear Regulatory Commission (NRC) Small Business Innovation research (SBIR) Contract investigated ten integrated leakage rate test (ILRT) analysis models which have been proposed for evaluation of ILRT data. This contract involved in-depth analysis of two ILRTs with data collected at accelerated rates and 80 conventional ILRTs with data collected at a frequency between 10-15 minutes. All ten methods were applied to all data. The study considered the appropriateness of each method to analyze containment data (air mass versus time), the influence of data collection frequency on ILRT duration, and the influence of collection frequency on each method. The study is described in the paper. Results are presented

  20. Ship Compliance in Emission Control Areas: Technology Costs and Policy Instruments.

    Science.gov (United States)

    Carr, Edward W; Corbett, James J

    2015-08-18

    This paper explores whether a Panama Canal Authority pollution tax could be an effective economic instrument to achieve Emission Control Area (ECA)-like reductions in emissions from ships transiting the Panama Canal. This tariff-based policy action, whereby vessels in compliance with International Maritime Organisation (IMO) ECA standards pay a lower transit tariff than noncompliant vessels, could be a feasible alternative to petitioning for a Panamanian ECA through the IMO. A $4.06/container fuel tax could incentivize ECA-compliant emissions reductions for nearly two-thirds of Panama Canal container vessels, mainly through fuel switching; if the vessel(s) also operate in IMO-defined ECAs, exhaust-gas treatment technologies may be cost-effective. The RATES model presented here compares current abatement technologies based on hours of operation within an ECA, computing costs for a container vessel to comply with ECA standards in addition to computing the Canal tax that would reduce emissions in Panama. Retrofitted open-loop scrubbers are cost-effective only for vessels operating within an ECA for more than 4500 h annually. Fuel switching is the least-cost option to industry for vessels that operate mostly outside of ECA regions, whereas vessels operating entirely within an ECA region could reduce compliance cost with exhaust-gas treatment technology (scrubbers).

  1. Conditioning of root canal anatomy on static and dynamics of nickel-titanium rotary instruments

    Directory of Open Access Journals (Sweden)

    Italo Di Giuseppe

    2015-11-01

    Conclusions: Therefore, in some cases, we would need an instrument that can reconcile efficiency with a reduction of mass and torque; the ideal instrument should have a very contained working part, combining efficiency with the decrease of mass and, consequently, of torsional stresses too.

  2. Conference on instrumental activation analysis IAA 92

    International Nuclear Information System (INIS)

    Frana, J.; Obrusnik, I.

    1992-05-01

    The publication contains 26 abstracts primarily concerned with neutron activation analysis, although other analytical techniques based on X-ray fluorescence analysis, PIXE, PIGE, RBS are also included. Some contributions deal with aspects of quality practice and assurance in radioanalytical laboratories, with marketing of instrumental neutron activation analysis services, with hard- and software aspects of radiation detection, etc. (Z.S.)

  3. Energy efficiency in existing detached housing. Danish experiences with different policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Gram-Hanssen, K.; Haunstrup Christensen, T. (Aalborg Univ., Danish Building Research Institute, Hoersholm (Denmark))

    2011-07-01

    This report contains a memo written as an input to the German project Enef-haus on energy-efficient restoration of single-family houses in Germany. The memo contains a summary of the Danish experiences divided into three main sections: first is a short historic overview of the Danish energy policy indicating when different relevant instruments have been introduced to increase the energy efficiency of privately owned single-family houses. Second is a short introduction to the Danish housing sector and its energy supplies. The third and main part of the report is an examination of the most recent and relevant instruments concluding both on the results concerning the impact of the instruments especially on owners of single-family houses and on more general experiences with their implementation. Finally the memo concludes on the general lessons that can be learned from the Danish experiences. (Author)

  4. Instrument reliability for high-level nuclear-waste-repository applications

    International Nuclear Information System (INIS)

    Rogue, F.; Binnall, E.P.; Armantrout, G.A.

    1983-01-01

    Reliable instrumentation will be needed to evaluate the characteristics of proposed high-level nuclear-wasted-repository sites and to monitor the performance of selected sites during the operational period and into repository closure. A study has been done to assess the reliability of instruments used in Department of Energy (DOE) waste repository related experiments and in other similar geological applications. The study included experiences with geotechnical, hydrological, geochemical, environmental, and radiological instrumentation and associated data acquisition equipment. Though this paper includes some findings on the reliability of instruments in each of these categories, the emphasis is on experiences with geotechnical instrumentation in hostile repository-type environments. We review the failure modes, rates, and mechanisms, along with manufacturers modifications and design changes to enhance and improve instrument performance; and include recommendations on areas where further improvements are needed

  5. Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use

    Directory of Open Access Journals (Sweden)

    Gianluca Gambarini

    2017-01-01

    Full Text Available Objectives: The aim of the present study was to investigate the incidence of deformation and fracture of twisted file adaptive nickel-titanium instruments after repeated clinical use and to identify and check whether the three instruments within the small/medium sequence showed similar or different visible signs of metal fatigue. Material and Methods: One-hundred twenty twisted file adaptive (TFA packs were collected after clinically used to prepare three molars and were inspected for deformations and fracture. Results: The overall incidence of deformation was 22.2%, which was not evenly distributed within the instruments: 15% for small/medium (SM1 (n = 18, 38.33% for SM2 (n = 46 and 13.33% for the SM3 instruments (n = 16. The defect rate of SM2 instruments was statistically higher than the other two (P < 0.001. The fracture rate was 0.83% (n = 3, being two SM2 instruments and one SM3. Conclusions: It was observed a very low defect rate after clinical use of twisted file adaptive rotary instruments. The untwisting of flutes was significantly more frequent than fracture, which might act as prevention for breakage. The results highlight the fact that clinicians should be aware that instruments within a sequence might be differently subjected to intracanal stress.

  6. Proceedings of the workshop on neutron scattering instrumentation for SNQ

    International Nuclear Information System (INIS)

    Scherm, R.; Stiller, H.

    1984-10-01

    These proceedings contain the articles presented at the named workshop. These concern instrumentation for neutron diffraction with special regards to small angle scattering, diffuse scattering, inelastic scattering, high resolution spectroscopy, and special techniques. (HSI)

  7. Turkish Accounting Standards, IAS - 39 "Financial Instruments: Recognition and Measurement" Under the Cash Flow Hedge Derivative Products Use: The Case of Forward

    Directory of Open Access Journals (Sweden)

    Emine ÇINA BAL

    2013-06-01

    Full Text Available Businesses face interest rate, exchange rate, liquidity, use derivative financial instruments to hedge against such risks. Forward transactions with derivative financial instruments, the non-organized markets, interest rates pre-determined future date, foreign currency contracts that contain delivery of goods as well as financial assets. Cash flow hedge that forms the subject of this study, a recognized asset or liability or a highly probable forecast transaction and the net profit or loss attributable to a particular risk of affecting the nature of a cash flow hedge to hedge changes in the process. Study the case of the application of foreign money has a tangible fixed asset purchases. Related to the purchase of tangible fixed assets at future foreign mercenaries were forward contracts to hedge the cash flow risk. Forward contracts, principal accounts on the balance sheet in accordance with IAS 39 Standard, derivative financial instruments are shown as fixed assets. The fair value of the contract during the contract period at the end of the period to show the valuation differences arising from the valuation of equity shown in the balance sheet. Net valuation differences arising from the contract are accounted for by two separate options. The first option, the net costs associated with the asset valuation difference. The second option is deducted from the amount of depreciation for the asset at the end of the period.

  8. Comparison of SANS instruments at reactors and pulsed sources

    International Nuclear Information System (INIS)

    Thiyagarajan, P.; Epperson, J.E.; Crawford, R.K.; Carpenter, J.M.; Hjelm, R.P. Jr.

    1992-01-01

    Small angle neutron scattering is a general purpose technique to study long range fluctuations and hence has been applied in almost every field of science for material characterization. SANS instruments can be built at steady state reactors and at the pulsed neutron sources where time-of-flight (TOF) techniques are used. The steady state instruments usually give data over small q ranges and in order to cover a large q range these instruments have to be reconfigured several times and SANS measurements have to be made. These instruments have provided better resolution and higher data rates within their restricted q ranges until now, but the TOF instruments are now developing to comparable performance. The TOF-SANS instruments, by using a wide band of wavelengths, can cover a wide dynamic q range in a single measurement. This is a big advantage for studying systems that are changing and those which cannot be exactly reproduced. This paper compares the design concepts and performances of these two types of instruments

  9. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ridyard, A

    2000-07-01

    The 'Erythemal Action Spectrum' shows an increase of 10{sup 3} in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  10. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    International Nuclear Information System (INIS)

    Ridyard, A.

    2000-01-01

    The 'Erythemal Action Spectrum' shows an increase of 10 3 in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  11. Instrument for Study of Microbial Thermal Inactivation

    Science.gov (United States)

    Dickerson, R. W.; Read, R. B.

    1968-01-01

    An instrument was designed for the study of thermal inactivation of microorganisms using heating times of less than 1 sec. The instrument operates on the principle of rapid automatic displacement of the microorganism to and from a saturated steam atmosphere, and the operating temperature range is 50 to 90 C. At a temperature of 70 C, thermometric lag (time required to respond to 63.2% of a step change) of the fluid sample containing microorganisms was 0.12 sec. Heating time required to heat the sample to within 0.1 C of the exposure temperature was less than 1 sec, permitting exposure periods as brief as 1 sec, provided the proper corrections are made for the lethal effect of heating. The instrument is most useful for heat exposure periods of less than 5 min, and, typically, more than 500 samples can be processed for microbial inactivation determinations within an 8-hr period. Images Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 7 Fig. 8 PMID:4874466

  12. Elements for computing and forecasting the leakage rate of the inner containment of nuclear reactor buildings

    International Nuclear Information System (INIS)

    Asali, M.; Capra, B.; Mazars, J.; Colliat, J.B.

    2015-01-01

    This study aims at introducing a methodology based on a macro-element discretization to compute and forecast the air leak rate of double-wall reactor buildings during air pressure tests. Assumptions at the basis of a weakly coupled strategy are checked in the case of a typical porous concrete section of an inner containment modeled during a 33 year period including four decennial regulatory pressure tests. However, air leakage due to porosity is only part of in situ measurements. Leakage due to cracking is another part and should be taken into account. A first macro-element is then presented, that superimposes Darcy flow within a porous matrix together with Poiseuille flow within a crack. Those elements are then used in a 3D hydraulic model to compute more accurately the total air leakage rate of considered structures. (authors)

  13. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  14. Advanced local dose rate calculations with the Monte Carlo code MCNP for plutonium nitrate storage containers

    International Nuclear Information System (INIS)

    Quade, U.

    1994-01-01

    Neutron- und Gamma dose rate calculations were performed for the storage containers filled with plutonium nitrate of the MOX fabrication facility of Siemens. For the particle transport calculations the Monte Carlo Code MCNP 4.2 was used. The calculated results were compared with experimental dose rate measurements. It can be stated that the choice of the code system was appropriate since all aspects of the many facettes of the problem were well reproduced in the calculations. The position dependency as well as the influence of the shieldings, the reflections and the mutual influences of the sources were well described by the calculations for the gamma and for the neutron dose rates. However, good agreement with the experimental results on the gamma dose rates could only be reached when the lead shielding of the detector was integrated into the geometry modelling of the calculations. For some few cases of thick shieldings and soft gamma ray sources the statistics of the calculational results were not sufficient. In such cases more elaborate variance reduction methods must be applied in future calculations. Thus the MCNP code in connection with NGSRC has been proven as an effective tool for the solution of this type of problems. (orig./HP) [de

  15. Vehicle for transporting instruments for testing against a wall

    International Nuclear Information System (INIS)

    Hyde, E.A.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    This invention relates to a non-destructive testing apparatus and, in particular, to a vehicle that can be moved at will, for transporting instruments for testing against a surface remote from the operator. Under this invention a vehicle is intended, for instance, for testing the vessel of an installation containing a liquid metal cooled nuclear reactor of the pond type. Such an installation includes a nuclear reactor comprising an assembly containing a nuclear fuel immersed in a pond of liquid metal coolant, located in a vessel which is itself placed in a concrete containment vessel [fr

  16. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  17. Interest rate derivatives

    DEFF Research Database (Denmark)

    Svenstrup, Mikkel

    This Ph.D. thesis consists of four self-contained essays on valuation of interest rate derivatives. In particular derivatives related to management of interest rate risk care are considered.......This Ph.D. thesis consists of four self-contained essays on valuation of interest rate derivatives. In particular derivatives related to management of interest rate risk care are considered....

  18. Rapid Sampling from Sealed Containers

    International Nuclear Information System (INIS)

    Johnston, R.G.; Garcia, A.R.E.; Martinez, R.K.; Baca, E.T.

    1999-01-01

    The authors have developed several different types of tools for sampling from sealed containers. These tools allow the user to rapidly drill into a closed container, extract a sample of its contents (gas, liquid, or free-flowing powder), and permanently reseal the point of entry. This is accomplished without exposing the user or the environment to the container contents, even while drilling. The entire process is completed in less than 15 seconds for a 55 gallon drum. Almost any kind of container can be sampled (regardless of the materials) with wall thicknesses up to 1.3 cm and internal pressures up to 8 atm. Samples can be taken from the top, sides, or bottom of a container. The sampling tools are inexpensive, small, and easy to use. They work with any battery-powered hand drill. This allows considerable safety, speed, flexibility, and maneuverability. The tools also permit the user to rapidly attach plumbing, a pressure relief valve, alarms, or other instrumentation to a container. Possible applications include drum venting, liquid transfer, container flushing, waste characterization, monitoring, sampling for archival or quality control purposes, emergency sampling by rapid response teams, counter-terrorism, non-proliferation and treaty verification, and use by law enforcement personnel during drug or environmental raids

  19. Breastfeeding Self-efficacy: A Critical Review of Available Instruments

    Science.gov (United States)

    Tuthill, Emily L.; McGrath, Jacqueline M.; Graber, Melanie; Cusson, Regina M.; Young, Sera L.

    2016-01-01

    Increasing breastfeeding rates in the United States is a national priority. Yet, initiation and duration of breastfeeding remains below national targets. Breastfeeding self-efficacy has been shown to be a strong predictor of both breastfeeding initiation and duration and is therefore an important characteristic to be able to measure. However, there is currently a myriad of instruments for measuring breastfeeding self-efficacy, which makes selection of an appropriate instrument difficult. Thus, our aim was to identify, compare, and critically review available breastfeeding self-efficacy instruments. In a systematic review, 6 breastfeeding self-efficacy instruments were identified. The instruments’ purposes, theoretical framework, final scale development, and application in 5 most recent settings were analyzed. The 6 breastfeeding self-efficacy instruments apply a number of theoretical and conceptual frameworks in their development, with Bandura’s social cognitive theory being most common. Content, construct, and predictive validity were strong for most scales. Some, but not all, have been successfully adapted to novel settings. In sum, there are several measurements of breastfeeding self-efficacy that can and should be employed to better understand reasons for suboptimal breastfeeding rates and the effects of interventions on breastfeeding self-efficacy. Instrument selection should be based on domains of primary interest, time available, peripartum timing, and assessment of previous adaptations. Failure to apply appropriate measures in research may garner results that are inconclusive, inaccurate, or nonrepresentative of true study effects. PMID:26319113

  20. Neutrons and music: Imaging investigation of ancient wind musical instruments

    Science.gov (United States)

    Festa, G.; Tardino, G.; Pontecorvo, L.; Mannes, D. C.; Senesi, R.; Gorini, G.; Andreani, C.

    2014-10-01

    A set of seven musical instruments and two instruments cares from the 'Fondo Antico della Biblioteca del Sacro Convento' in Assisi, Italy, were investigated through neutron and X-ray imaging techniques. Historical and scientific interests around ancient musical instruments motivate an intense research effort for their characterization using non-destructive and non-invasive techniques. X-ray and neutron tomography/radiography were applied to the study of composite material samples containing wood, hide and metals. The study was carried out at the NEUTRA beamline, PSI (Paul Scherrer Institute, Switzerland). Results of the measurements provided new information on the composite and multi-scale structure, such as: the internal structure of the samples, position of added materials like metals, wood fiber displays, deformations, presence of adhesives and their spatial distribution and novel insight about construction methods to guide the instruments' restoration process.

  1. Use of modern software - based instrumentation in safety critical systems

    International Nuclear Information System (INIS)

    Emmett, J.; Smith, B.

    2005-01-01

    Many Nuclear Power Plants are now ageing and in need of various degrees of refurbishment. Installed instrumentation usually uses out of date 'analogue' technology and is often no longer available in the market place. New technology instrumentation is generally un-qualified for nuclear use and specifically the new 'smart' technology contains 'firmware', (effectively 'soup' (Software of Uncertain Pedigree)) which must be assessed in accordance with relevant safety standards before it may be used in a safety application. Particular standards are IEC 61508 [1] and the British Energy (BE) PES (Programmable Electronic Systems) guidelines EPD/GEN/REP/0277/97. [2] This paper outlines a new instrument evaluation system, which has been developed in conjunction with the UK Nuclear Industry. The paper concludes with a discussion about on-line monitoring of Smart instrumentation in safety critical applications. (author)

  2. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  3. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  4. Development of intelligent system for a thermal analysis instrument

    International Nuclear Information System (INIS)

    Xu Xiaoli; Wu Guoxin; Shi Yongchao

    2005-01-01

    The key techniques for the intelligent analysis instrument developed are proposed. Based on the technique of virtual instrumentation, the intelligent PID control algorithm to control the temperature of thermal analysis instrument is described. The dynamic character and the robust performance of traditional PID controls are improved through the dynamic gain factor, temperature rate change factor, the forecast factor, and the temperature correction factor is introduced. Using the graphic development environment of LabVIEW, the design of system modularization and the graphic display are implemented. By means of multiple mathematical modules, intelligent data processing is realized

  5. Instruments to assess self-care among healthy children: A systematic review of measurement properties.

    Science.gov (United States)

    Urpí-Fernández, Ana-María; Zabaleta-Del-Olmo, Edurne; Montes-Hidalgo, Javier; Tomás-Sábado, Joaquín; Roldán-Merino, Juan-Francisco; Lluch-Canut, María-Teresa

    2017-12-01

    To identify, critically appraise and summarize the measurement properties of instruments to assess self-care in healthy children. Assessing self-care is a proper consideration for nursing practice and nursing research. No systematic review summarizes instruments of measurement validated in healthy children. Psychometric review in accordance with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. MEDLINE, CINAHL, PsycINFO, Web of Science and Open Grey were searched from their inception to December 2016. Validation studies with a healthy child population were included. Search was not restricted by language. Two reviewers independently assessed the methodological quality of included studies using the COSMIN checklist. Eleven studies were included in the review assessing the measurement properties of ten instruments. There was a maximum of two studies per instrument. None of the studies evaluated the properties of test-retest reliability, measurement error, criterion validity and responsiveness. Internal consistency and structural validity were rated as "excellent" or "good" in four studies. Four studies were rated as "excellent" in content validity. Cross-cultural validity was rated as "poor" in the two studies (three instruments) which cultural adaptation was carried out. The evidence available does not allow firm conclusions about the instruments identified in terms of reliability and validity. Future research should focus on generate evidence about a wider range of measurement properties of these instruments using a rigorous methodology, as well as instrument testing on different countries and child population. © 2017 John Wiley & Sons Ltd.

  6. Predicted summary of panel discussion on smart instruments

    International Nuclear Information System (INIS)

    Sorber, R.E.

    1991-01-01

    The following is a hypothetical account of a panel discussion on Smart Instruments. It enumerates topics that are likely to covered in the actual discussion. A smart instrument may be defined as one that performs smart functions or as one that contains a computer of some sort. Neither definition is perfect. Smart functions might include, but are not limited to: automated data logging (reading, location, time); transfer (downloading) logged data to outside computer; computer assisted, remote calibration; linearity and dead time correction; performance trending; self diagnosis of faults; detector probe recognition; automated beta factor application; and automatic range selection. These smart functions are discussed

  7. NASA Instrument Cost/Schedule Model

    Science.gov (United States)

    Habib-Agahi, Hamid; Mrozinski, Joe; Fox, George

    2011-01-01

    NASA's Office of Independent Program and Cost Evaluation (IPCE) has established a number of initiatives to improve its cost and schedule estimating capabilities. 12One of these initiatives has resulted in the JPL developed NASA Instrument Cost Model. NICM is a cost and schedule estimator that contains: A system level cost estimation tool; a subsystem level cost estimation tool; a database of cost and technical parameters of over 140 previously flown remote sensing and in-situ instruments; a schedule estimator; a set of rules to estimate cost and schedule by life cycle phases (B/C/D); and a novel tool for developing joint probability distributions for cost and schedule risk (Joint Confidence Level (JCL)). This paper describes the development and use of NICM, including the data normalization processes, data mining methods (cluster analysis, principal components analysis, regression analysis and bootstrap cross validation), the estimating equations themselves and a demonstration of the NICM tool suite.

  8. Time trends of period prevalence rates of patients with inhaled long-acting beta-2-agonists-containing prescriptions: a European comparative database study.

    Directory of Open Access Journals (Sweden)

    Marietta Rottenkolber

    Full Text Available Inhaled, long-acting beta-2-adrenoceptor agonists (LABA have well-established roles in asthma and/or COPD treatment. Drug utilisation patterns for LABA have been described, but few studies have directly compared LABA use in different countries. We aimed to compare the prevalence of LABA-containing prescriptions in five European countries using a standardised methodology.A common study protocol was applied to seven European healthcare record databases (Denmark, Germany, Spain, the Netherlands (2, and the UK (2 to calculate crude and age- and sex-standardised annual period prevalence rates (PPRs of LABA-containing prescriptions from 2002-2009. Annual PPRs were stratified by sex, age, and indication (asthma, COPD, asthma and COPD.From 2002-2009, age- and sex-standardised PPRs of patients with LABA-containing medications increased in all databases (58.2%-185.1%. Highest PPRs were found in men ≥ 80 years old and women 70-79 years old. Regarding the three indications, the highest age- and sex-standardised PPRs in all databases were found in patients with "asthma and COPD" but with large inter-country variation. In those with asthma or COPD, lower PPRs and smaller inter-country variations were found. For all three indications, PPRs for LABA-containing prescriptions increased with age.Using a standardised protocol that allowed direct inter-country comparisons, we found highest rates of LABA-containing prescriptions in elderly patients and distinct differences in the increased utilisation of LABA-containing prescriptions within the study period throughout the five European countries.

  9. TENERIFE program: high temperature experiments on A 4 tons UF6 container

    International Nuclear Information System (INIS)

    Casselman, C.; Duret, B.; Seiler, J.M.; Ringot, C.; Warniez, P.; Wataru, M.; Shiomi, S.; Ozaki, S.; Yamakawa, H.

    1993-01-01

    To know the input of the future thermo-mechanical code, we have to get a better understanding of the thermo-physical evolution of the UF 6 which pressurizes the container. This evolution is function of: a) the heat transfer rate from the fire to the container b) the UF 6 behaviour in the container. These tests are essentially analytical at simulated fire temperatures of between 800 and 1000degC. They use a representative mass of UF 6 (around 4 tons). The tests will not seek to rupture the test container which has a diameter equal to the 48Y container, but shorter length. These tests carried out in realistic conditions (typical thermal gradient at the wall, characteristic period for UF 6 internal mass transfer) should make possible to improve knowledge of two fundamental phenomena: 1) vaporization of UF 6 on contact with the heated wall (around 400degC), a phenomenon which controls the container internal pressurization kinetic, 2) the equivalent conductivity of solid UF 6 , a phenomenon which is linked to the heat transfer by UF 6 vaporization-condensation through the solid's porosities and which depends on the diameter of the container. In addition, they will allow the influence of other parameters to be studied, such as UF 6 container filling mode or the mechanical characteristics of the container material. A UF 6 container fitted with instruments (wall temperature, UF 6 temperature, pressure) is heated by a rapid heat transient in a radiating furnace where the temperature and thermal power supplied can be measured. The test continues until pre-established thresholds have been reached: 1) strain threshold measured on the container surface (strain gauges positioned on the outside), 2) maximum temperature threshold of UF 6 , 3) container internal pressure threshold. (J.P.N.)

  10. The function of single containment and double containment of PWR nuclear power plant

    International Nuclear Information System (INIS)

    Chen Weijing.

    1985-01-01

    The function and structures of single containment and double containment of PWR nuclear power plant were described briefiy. The dissimilarites of diffent type of containments, which effects the impact of environment are discused. The impact of environment, effected by 'source term', containment gas leak rate and diffusion pattern of the released gas, under different operating condition is analysed. Especially, the impact of environment under LOCA accident is fully analysed

  11. Proposed shake table studies for NAPP containment

    International Nuclear Information System (INIS)

    Akolkar, P.M.; Khuddus, M.A.

    1975-01-01

    The proposal for shake table studies on model of containment structure of Narora Atomic Power Project is discussed. The physical characteristics such as the dimensions, connection details of the containment with the internal structure and the dynamic interaction between the two have been described. The dynamic scale factors obtained through similitude requirements and dimensional analysis have been presented and the modelling aspects and the choice of model material and scale have been discussed. The proposed type of tests, necessary measurement and instrumentation have been mentioned. The limitations imposed by similitude requirements on model studies are brought out and the usefulness of the results of the proposed tests in the dynamic design of the containment have been covered. (author)

  12. Monte Carlo simulation of neutron scattering instruments

    International Nuclear Information System (INIS)

    Seeger, P.A.

    1995-01-01

    A library of Monte Carlo subroutines has been developed for the purpose of design of neutron scattering instruments. Using small-angle scattering as an example, the philosophy and structure of the library are described and the programs are used to compare instruments at continuous wave (CW) and long-pulse spallation source (LPSS) neutron facilities. The Monte Carlo results give a count-rate gain of a factor between 2 and 4 using time-of-flight analysis. This is comparable to scaling arguments based on the ratio of wavelength bandwidth to resolution width

  13. Fine-scale environmental effects on Cape hake survey catch rates in the Northern Benguela, using data from a trawl-mounted instrument package

    DEFF Research Database (Denmark)

    Kainge, Paulus Inekela; Wieland, Kai

    2017-01-01

    We investigated fine-scale effects of environmental variables associated with habitat distribution for 4 size groups of Cape hakes, Merluccius capensis and M. paradoxus, using generalized additive models (GAMs) with a negative binominal error distribution. This study took place during the Namibian...... hake trawl survey of 2016, and was made possible for the first time in Namibia by collecting oceanographic information with a trawl-mounted instrument package concurrently with the catch data. Depth, geographical position, bottom oxygen and bottom temperature had the most pronounced effect on the catch...... rates of both hake species, whereas solar zenith angle representing diel effects and surface layer chlorophyll appeared to be less important. The explained deviance for the best models ranged from 71.4% for M. capensis to 92.7% for M. paradoxus between 43 and 57 cm in length. Differences in catch rates...

  14. Personal assistance, income and employment: the spinal injuries survey instrument (SISI) and its application in a sample of people with quadriplegia.

    Science.gov (United States)

    Rowell, D; Connelly, L B

    2008-06-01

    Our aim was to ascertain what effect access to personal care package (PCP) has on the labour market activities of people who have a spinal cord injury (SCI). We developed a new instrument called the spinal injuries survey instrument (SISI). The SISI is a 35-item instrument, which contains items on health, education, employment, along with measures of personal assistance, mobility and psychological attribution style. The SISI was administered, with the Short Form 36 (SF-36) health status instrument, to 250 people with an SCI. The response rate was 72%. A retrospective, matched case-control sampling approach matched individuals who received a PCP, with a cohort who did not. The matching criteria included the site and severity of spinal lesion, age and gender. Although data on the reliability of the instrument are currently lacking, our empirical results are consistent with other studies: (1) mean annual health care costs (AUD$8741) are comparable with Walsh's estimates (2) SF-36 data support Kreuter's contention that mental health is resilient to SCI and (3) a post-injury employment rate of 29.7% corroborates Murphy et al. We present additional data describing income, educational attainment and family support. Our discussion borrows a conceptualization of disability by Sen, that includes both an 'earning handicap' (an impediment to earn income) and a 'conversion handicap' (an impediment to the enjoyment of income). Our application of the SISI provides evidence of both. The labour income of people with quadriplegia is AUD$10,007 per annum, while diminished health status, increased out-of-pocket health expenditure and loss of time suggest a conversion handicap.

  15. The Vector Electric Field Instrument on the C/NOFS Satellite

    Science.gov (United States)

    Pfaff, R.; Kujawski, J.; Uribe, P.; Bromund, K.; Fourre, R.; Acuna, M.; Le, G.; Farrell, W.; Holzworth, R.; McCarthy, M.; hide

    2008-01-01

    We provide an overview of the Vector Electric Field Instrument (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA GSFC instrument designed 1) to investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) to determine the electric fields associated with abrupt, large amplitude, density depletions and 3) to quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions or Equatorial Spread-F. The VEFI instrument includes a vector electric field double probe detector, a Langmuir trigger probe, a flux gate magnetometer, a lightning detector and associated electronics. The heart of the instrument is the set of double probe detectors designed to measure DC and AC electric fields using 6 identical, mutually orthogonal, deployable 9.5 m booms tipped with 10 cm diameter spheres containing embedded preamplifiers. A description of the instrument and its sensors will be presented. If available, representative measurements will be provided.

  16. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  17. Burning rates of hydrogen-air mixtures in containment buildings and the consequent pressure transients

    International Nuclear Information System (INIS)

    Tennankore, K.N.; Kumar, R.K.; Razzaghi, M.

    1987-01-01

    One-dimensional flame models are often used to predict the pressure transients caused by hydrogen combustion in containments during postulated severe accidents. In the absence of data, these models account for prevailing flame acceleration mechanisms, such as initial turbulence, venting and obstacle-induced turbulence, by using arbitrarily large burning velocities that are much higher than laminar burning velocities. Using an intermediate-scale test facility at the Whiteshell Nuclear Research Establishment we have obtained necessary data on the effects of flame acceleration mechanisms, to estimate the safety margin in the buring velocities used in the models. So far, data have been analyzed, with a one-dimensional model, to determine effective burning velocities and burning-rate enhancement factors. The results of the analyses indicate that the effect of initial turbulence on the burning rate can be bounded only if the effect of flame-generated turbulence is included. The effect of venting can be accounted for by using two burning velocities, one for the pre-vent duration and a second increased value during the vented-combustion stage. The enhancement factors due to these two mechanisms, for the different conditions analyzed, varied up to 5.4, and the effective burning velocities varied up to 8.4 m/s

  18. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid ''L''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs

  19. Measuring Medical Housestaff Teamwork Performance Using Multiple Direct Observation Instruments: Comparing Apples and Apples.

    Science.gov (United States)

    Weingart, Saul N; Yaghi, Omar; Wetherell, Matthew; Sweeney, Megan

    2018-04-10

    To examine the composition and concordance of existing instruments used to assess medical teams' performance. A trained observer joined 20 internal medicine housestaff teams for morning work rounds at Tufts Medical Center, a 415-bed Boston teaching hospital, from October through December 2015. The observer rated each team's performance using 9 teamwork observation instruments that examined domains including team structure, leadership, situation monitoring, mutual support, and communication. Observations recorded on paper forms were stored electronically. Scores were normalized from 1 (low) to 5 (high) to account for different rating scales. Overall mean scores were calculated and graphed; weighted scores adjusted for the number of items in each teamwork domain. Teamwork scores were analyzed using t-tests, pair-wise correlations, and the Kruskal-Wallis statistic, and team performance was compared across instruments by domain. The 9 tools incorporated 5 major domains, with 5-35 items per instrument for a total of 161 items per observation session. In weighted and unweighted analyses, the overall teamwork performance score for a given team on a given day varied by instrument. While all of the tools identified the same low outlier, high performers on some instruments were low performers on others. Inconsistent scores for a given team across instruments persisted in domain-level analyses. There was substantial variation in the rating of individual teams assessed concurrently by a single observer using multiple instruments. Since existing teamwork observation tools do not yield concordant assessments, researchers should create better tools for measuring teamwork performance.

  20. How Social Care Beneficiaries in Poland Rate Relative Harmfulness of Various Tobacco and Nicotine-Containing Products.

    Science.gov (United States)

    Milcarz, Marek; Polańska, Kinga; Bak-Romaniszyn, Leokadia; Kaleta, Dorota

    2017-09-07

    The aim of the study was to examine how social care beneficiaries rate the relative harmfulness of tobacco/nicotine-containing products compared to traditional cigarettes. This information is crucial for the development of effective tobacco control strategies targeting disadvantaged populations. The cross-sectional study covered 1817 respondents who were taking advantage of social aid services offered by the local social care institutions in the Piotrkowski district, via face-to-face interviews. The linear regression analysis indicated that relative to women, men consider slim cigarettes, smokeless tobacco and e-cigarettes to be more harmful than traditional cigarettes ( p traditional cigarettes reported menthol cigarettes to be less harmful than traditional cigarettes, relative to the non-smokers ( p = 0.05). The current results demonstrate that social care beneficiaries are not aware of the fact that some products are less harmful than others. Education concerning tobacco/nicotine products should include advice on how to reduce the adverse health effects of smoking (e.g., avoiding inhalation of combusted products), while driving the awareness that no nicotine-containing products are safe.

  1. LabVIEW 2010 Computer Vision Platform Based Virtual Instrument and Its Application for Pitting Corrosion Study.

    Science.gov (United States)

    Ramos, Rogelio; Zlatev, Roumen; Valdez, Benjamin; Stoytcheva, Margarita; Carrillo, Mónica; García, Juan-Francisco

    2013-01-01

    A virtual instrumentation (VI) system called VI localized corrosion image analyzer (LCIA) based on LabVIEW 2010 was developed allowing rapid automatic and subjective error-free determination of the pits number on large sized corroded specimens. The VI LCIA controls synchronously the digital microscope image taking and its analysis, finally resulting in a map file containing the coordinates of the detected probable pits containing zones on the investigated specimen. The pits area, traverse length, and density are also determined by the VI using binary large objects (blobs) analysis. The resulting map file can be used further by a scanning vibrating electrode technique (SVET) system for rapid (one pass) "true/false" SVET check of the probable zones only passing through the pit's centers avoiding thus the entire specimen scan. A complete SVET scan over the already proved "true" zones could determine the corrosion rate in any of the zones.

  2. Local tax interaction with multiple tax instruments: evidence from Flemish municipalities

    OpenAIRE

    S. VAN PARYS; B. MERLEVEDE; T. VERBEKE

    2010-01-01

    We investigate the long run result of strategic interaction among local jurisdictions using multiple tax instruments. Most studies about local policy interaction only consider a single policy instrument. With multiple tax instruments, however, tax interaction is more complex. We construct a simple theoretical framework based on a basic spillover model, with two tax rates and immobile resources. We show that the signs of within and cross tax interaction crucially depend on the extent to which ...

  3. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  4. Stopped-pipe wind instruments: Acoustics of the panpipes

    Science.gov (United States)

    Fletcher, N. H.

    2005-01-01

    Stopped-pipe jet-excited musical instruments are known in many cultures, those best-known today being the panpipes or syrinx of Eastern Europe and of the Peruvian Andes. Although the playing style differs, in each case the instrument consists of a set of graduated bamboo pipes excited by blowing across the open tops. Details of the excitation aerodynamics warrant examination, particularly as the higher notes contain amplitudes of the even harmonics approaching those of the odd harmonics expected from a stopped pipe. Analysis shows that the jet offset is controlled by the fluid dynamics of the jet, and is such that appreciable even-harmonic excitation is generated. The theory is largely confirmed by measurements on a player. .

  5. Statistical evaluation of recorded knowledge in nuclear and other instrumental analytical techniques

    International Nuclear Information System (INIS)

    Braun, T.

    1987-01-01

    The main points addressed in this study are the following: Statistical distribution patterns of published literature on instrumental analytical techniques 1981-1984; structure of scientific literature and heuristics for identifying active specialities and emerging hot spot research areas in instrumental analytical techniques; growth and growth rates of the literature in some of the identified hot research areas; quality and quantity in instrumental analytical research output. (orig.)

  6. Advances in constant-velocity Moessbauer instrumentation

    International Nuclear Information System (INIS)

    Veiga, A.; Martinez, N.; Zelis, P. Mendoza; Pasquevich, G. A.; Sanchez, F. H.

    2006-01-01

    A prototype of a programmable constant-velocity scaler is presented. This instrument allows the acquisition of partial Moessbauer spectra in selected energy regions using standard drivers and transducers. It can be fully operated by a remote application, thus data acquisition can be automated. The instrument consists of a programmable counter and a constant-velocity reference. The reference waveform generator is amplitude modulated with 13-bit resolution, and is programmable in a wide range of frequencies and waveforms in order to optimize the performance of the transducer. The counter is compatible with most standard SCA, and is configured as a rate-meter that provides counts per selectable time slice at the programmed velocity. As a demonstration of the instrument applications, a partial Moessbauer spectrum of a natural iron foil was taken. Only positive energies were studied in 512 channels, accumulating 20 s per channel. A line width of 0.20 mm/s was achieved, performing with an efficiency of 80%.

  7. Temperature buffer test. Installation of buffer, heaters and instruments in the deposition hole

    Energy Technology Data Exchange (ETDEWEB)

    Johannesson, Lars-Erik; Sanden, Torbjoern; Aakesson, Mattias [Clay Technology AB, Lund (Sweden); Barcena, Ignacio; Garcia-Sineriz, Jose Luis [Aitemin, Madrid (Spain)

    2010-12-15

    During 2003 the Temperature Buffer Test was installed in Aespoe Hard Rock Laboratory. Temperature, water pressure, relative humidity, total pressure and displacements etc. are measured in numerous points in the test. Most of the cables from the transducers are led in the deposition hole through slots in the rock surface of the deposition hole in watertight tubes to the data collection system in a container placed in the tunnel close to the deposition hole. This report describes the work with the installations of the buffer, heaters, and instruments and yields a description of the final location of all instruments. The report also contains a description of the materials that were installed and the densities yielded after placement.

  8. Temperature buffer test. Installation of buffer, heaters and instruments in the deposition hole

    International Nuclear Information System (INIS)

    Johannesson, Lars-Erik; Sanden, Torbjoern; Aakesson, Mattias; Barcena, Ignacio; Garcia-Sineriz, Jose Luis

    2010-12-01

    During 2003 the Temperature Buffer Test was installed in Aespoe Hard Rock Laboratory. Temperature, water pressure, relative humidity, total pressure and displacements etc. are measured in numerous points in the test. Most of the cables from the transducers are led in the deposition hole through slots in the rock surface of the deposition hole in watertight tubes to the data collection system in a container placed in the tunnel close to the deposition hole. This report describes the work with the installations of the buffer, heaters, and instruments and yields a description of the final location of all instruments. The report also contains a description of the materials that were installed and the densities yielded after placement

  9. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  10. Diagnostic instrumentation for detection of the onset of steam tube leaks in PWRs

    International Nuclear Information System (INIS)

    Roach, W.H.

    1984-01-01

    Four tasks are addressed in this study of the detection of steam tube leaks: determination of which physical parameters indicate the onset of steam generator tube leaks; establishing performance goals for diagnostic instruments which could be used for early detection of steam generator tube leaks; defining the diagnostic instrumentation and their location which satisfy Items 1 and 2; and assessing the need for diagnostic data processing and display. Parameters are identified, performance goals established and sensor types and locations are specified in the report, with emphasis on the use of existing instrumentation with a minimum of retrofitting. A simple algorithm is developed which yields the leak rate as a function of known or measurable quantities. The conclusion is that leak rates of less than one-tenth gram per second should be detectable with existing instrumentation

  11. Containment and surveillance systems for international safeguards

    International Nuclear Information System (INIS)

    Ney, J.F.

    1978-01-01

    Important criteria in measuring the effectiveness of IAEA safeguards include timeliness of detection of diversion, timeliness of reporting such detections, and confidence in determining the amount of material diverted. Optimum use of IAEA inspectors, combined with adequate instrumentation, can provide a practical means for achieving these criteria. System studies are being carried out for different types of facilities that may come under IAEA safeguards to determine the proper balance between inspector's efforts and the use of safeguards instrumentation. A description of a typical study is presented. Based on the results of these studies, the program undertaken to develop those containment and surveillance subsystems for which the technical feasibility and operational acceptability need to be established is described

  12. Pipe line construction for reactor containment buildings

    International Nuclear Information System (INIS)

    Aoki, Masataka; Yoshinaga, Toshiaki

    1978-01-01

    Purpose: To prevent the missile phenomenon caused by broken fragments due to pipe whip phenomenon in a portion of pipe lines connected to a reactor containment from prevailing to other portions. Constitution: Various pipe lines connected to the pressure vessel are disposed at the outside of the containments and they are surrounded with a plurality of protection partition walls respectively independent from each other. This can eliminate the effect of missile phenomena upon pipe rupture from prevailing to the pipe lines and instruments. Furthermore this can afford sufficient spaces for the pipe lines, as well as for earthquake-proof supports. (Horiuchi, T.)

  13. Review of techniques and detectors used in instruments for field measurement of beta doses and dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1983-01-01

    Generally, field measurements are required to assess the hazard from #betta#-rays before personnel are allowed to occupy a working space or perform a task. Occasionally, the measurements are required for an assessment after a #betta#-ray exposure is suspected to have occurred. Until recently the dose or dose rate have been the quantities of interest but there is now felt to be a need to characterize the energies and directions of the #betta#-rays as well. The purpose of #betta#-dosimetry is the assessment of hazard to superficial tissues (within approx. 10 mm of the surface) and that these tissues may also be exposed simultaneously to other ionizing radiations. The #betta#-dosimetry technique must take account of this. With these uses of field instruments in mind the following detectors, and associated techniques will be discussed in terms of the measurement principles, advantages and limitations: thin-walled ion chambers (sometimes in combination with thick-walled ones or with covers thick enough to prevent penetration of #betta#-particles); thin scintillators, nearly tissue equivalent, to provide a detector analogous to skin; scintillators, thick enough to absorb all the energy of the #betta#-particles (circuitry is required to count pulses according to size to permit calculation of dose or dose rate); silicon diodes with thin detection layers operated as photocurrent generators; silicon diodes, reversed biassed, with pulses counted according to size; and simple pulse counters (e.g., GM counters or silicon diodes with thin windows)

  14. HANARO core channel flow-rate measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heon Il; Chae, Hee Tae; Im, Don Soon; Kim, Seon Duk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-06-01

    HANARO core consists of 23 hexagonal flow tubes and 16 cylindrical flow tubes. To get the core flow distribution, we used 6 flow-rate measuring dummy fuel assemblies (instrumented dummy fuel assemblies). The differential pressures were measured and converted to flow-rates using the predetermined relationship between AP and flow-rate for each instrumented dummy fuel assemblies. The flow-rate for the cylindrical flow channels shows +-7% relative errors and that for the hexagonal flow channels shows +-3.5% relative errors. Generally the flow-rates of outer core channels show smaller values compared to those of inner core. The channels near to the core inlet pipe and outlet pipes also show somewhat lower flow-rates. For the lower flow channels, the thermal margin was checked by considering complete linear power histories. From the experimental results, the gap flow-rate was estimated to be 49.4 kg/s (cf. design flow of 50 kg/s). 15 tabs., 9 figs., 10 refs. (Author) .new.

  15. Assessing hospitals' clinical risk management: Development of a monitoring instrument

    Directory of Open Access Journals (Sweden)

    Pfeiffer Yvonne

    2010-12-01

    Full Text Available Abstract Background Clinical risk management (CRM plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. Methods The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. Results The monitoring instrument consists of 28 main questions organized in three sections: 1 Implementation and organizational integration of CRM, 2 Strategic objectives and operational implementation of CRM at hospital level, and 3 Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian. It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. Conclusions We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  16. Assessing hospitals' clinical risk management: Development of a monitoring instrument.

    Science.gov (United States)

    Briner, Matthias; Kessler, Oliver; Pfeiffer, Yvonne; Wehner, Theo; Manser, Tanja

    2010-12-13

    Clinical risk management (CRM) plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals) was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. The monitoring instrument consists of 28 main questions organized in three sections: 1) Implementation and organizational integration of CRM, 2) Strategic objectives and operational implementation of CRM at hospital level, and 3) Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian). It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  17. Effects of Time-Release Caffeine Containing Supplement on Metabolic Rate, Glycerol Concentration and Performance

    Directory of Open Access Journals (Sweden)

    Adam M. Gonzalez, Jay R. Hoffman, Adam J. Wells, Gerald T. Mangine, Jeremy R. Townsend, Adam R. Jajtner, Ran Wang, Amelia A. Miramonti, Gabriel J. Pruna, Michael B. LaMonica, Jonathan D. Bohner, Mattan W. Hoffman, Leonardo P. Oliveira, David H. Fukuda, Maren S. Fragala, Jeffrey R. Stout

    2015-06-01

    Full Text Available This study compared caffeine pharmacokinetics, glycerol concentrations, metabolic rate, and performance measures following ingestion of a time-release caffeine containing supplement (TR-CAF versus a regular caffeine capsule (CAF and a placebo (PL. Following a double-blind, placebo-controlled, randomized, cross-over design, ten males (25.9 ± 3.2 y who regularly consume caffeine ingested capsules containing either TR-CAF, CAF, or PL. Blood draws and performance measures occurred at every hour over an 8-hour period. Plasma caffeine concentrations were significantly greater (p < 0.05 in CAF compared to TR-CAF during hours 2-5 and significantly greater (p = 0.042 in TR-CAF compared to CAF at hour 8. There were no significant differences between trials in glycerol concentrations (p = 0.86 or metabolic measures (p = 0.17-0.91. Physical reaction time was significantly improved for CAF at hour 5 (p=0.01 compared to PL. Average upper body reaction time was significantly improved for CAF and TR-CAF during hours 1-4 (p = 0.04 and p = 0.01, respectively and over the 8-hour period (p = 0.04 and p = 0.001, respectively compared to PL. Average upper body reaction time was also significantly improved for TR-CAF compared to PL during hours 5-8 (p = 0.004. TR-CAF and CAF showed distinct pharmacokinetics yielding modest effects on reaction time, yet did not alter glycerol concentration, metabolic measures, or other performance measures.

  18. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. ICFA Instrumentation Bulletin, Volume 22, Spring 2001 Issue (SLAC-J-ICFA-022)

    Energy Technology Data Exchange (ETDEWEB)

    Va' Vra, J.

    2003-10-21

    The publication of the ICFA Instrumentation Bulletin is an activity of the Panel on Future Innovation and Development of ICFA (International Committee for Future Accelerators). The Bulletin reports on research and progress in the field of instrumentation with emphasis on application in the field of high-energy physics. It encourages issues of generic instrumentation. This volume contains the following articles: (1) ''Gaseous Micropattern Detectors: High-Energy Physics and Beyond''; (2) ''DIRC Dreams Redux: Research Directions for the Next Generation of Internally Reflected Imaging Counters''; and (3) ''Corrosion of Glass Windows in DIRC PMTs''.

  20. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-01-03

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs.

  1. Beverage containers in municipal waste

    Energy Technology Data Exchange (ETDEWEB)

    Enhoerning, B

    1979-01-01

    The composition of containers (cans, glass) in Sweden's wastes is given. Recycling and reclamation of these containers are discussed. The energy demand of fabricating the containers is analyzed for recycling rates of 0 and 100%. The free forces of the market cannot be depended on to direct the containers back to the manufacturer; only a well-functioning deposit system can do this. 7 figures. (DLC)

  2. Experimental simulation of corium dispersion phenomena in direct containment heating

    International Nuclear Information System (INIS)

    Wu, Q.

    1996-01-01

    In a direct containment heating (DCH) accident scenario, the degree of corium dispersion is one of the most significant factors responsible for the reactor containment heating and pressurization. To study the mechanisms of the corium dispersion phenomenon, a DCH separate effect test facility of 1:10 linear scale for Zion PWR geometry is constructed. Experiments are carried out with air-water and air-woods metal simulating steam and molten core materials. The physical process of corium dispersion is studied in detail through various instruments, as well as with flow visualization at several locations. The accident transient begins with the liquid jet discharge at the bottom of the reactor pressure vessel. Once the jet impinges on the cavity bottom floor, it immediately spreads out and moves rapidly to the cavity exit as a film flow. Part of the discharged liquid flows out of the cavity before gas blowdown, and the rest is subjected to the entrainment process due to the high speed gas stream. The liquid film and droplet flows from the reactor cavity will then experience subcompartment trapping and re-entrainment. Consequently, the dispersed liquid droplets that follow the gas stream are transported into the containment atmosphere, resulting in containment heating and pressurization in the prototypic condition. Comprehensive measurements are obtained in this study, including the liquid jet velocity, liquid film thickness and velocity transients in the test cavity, gas velocity and velocity profile in the cavity, droplet size distribution and entrainment rate, and the fraction of dispersed liquid in the containment building. These data are of great importance for better understanding of the corium dispersion mechanisms. (orig.)

  3. Buoyancy package for self-contained acoustic doppler current profiler mooring

    Digital Repository Service at National Institute of Oceanography (India)

    Venkatesan, R.; Krishnakumar, V.

    A buoyancy package for self-contained Acoustic Doppler Current Profiler(SC-ADCP 1200 RD instruments USA) was designed and fabricated indigenously, for subsurface mooring in coastal waters. The system design is discussed. The design to keep SC...

  4. Metal-Containing Polystyrene Beads as Standards for Mass Cytometry.

    Science.gov (United States)

    Abdelrahman, Ahmed I; Ornatsky, Olga; Bandura, Dmitry; Baranov, Vladimir; Kinach, Robert; Dai, Sheng; Thickett, Stuart C; Tanner, Scott; Winnik, Mitchell A

    2010-01-01

    We examine the suitability of metal-containing polystyrene beads for the calibration of a mass cytometer instrument, a single particle analyser based on an inductively coupled plasma ion source and a time of flight mass spectrometer. These metal-containing beads are also verified for their use as internal standards for this instrument. These beads were synthesized by multiple-stage dispersion polymerization with acrylic acid as a comonomer. Acrylic acid acts as a ligand to anchor the metal ions within the interior of the beads. Mass cytometry enabled the bead-by-bead measurement of the metal-content and determination of the metal-content distribution. Beads synthesized by dispersion polymerization that involved three stages were shown to have narrower bead-to-bead variation in their lanthanide content than beads synthesized by 2-stage dispersion polymerization. The beads exhibited insignificant release of their lanthanide content to aqueous solutions of different pHs over a period of six months. When mixed with KG1a or U937 cell lines, metal-containing polymer beads were shown not to affect the mass cytometry response to the metal content of element-tagged antibodies specifically attached to these cells.

  5. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  6. CONCRETE REACTOR CONTAINMENT

    Energy Technology Data Exchange (ETDEWEB)

    Lumb, Ralph F.; Hall, William F.; Fruchtbaum, Jacob

    1963-06-15

    The results of various leak-rate tests demonstrate the practicality of concrete as primary containment for the maximum credible accident for a research reactor employing plate-type fuel and having a power in excess of one megawatt. Leak-test time was shortened substantially by measuring the relaxation time for overpressure decay, which is a function of leak rate. (auth)

  7. Use and maintenance of nuclear medicine instruments in Southeast Asia

    International Nuclear Information System (INIS)

    1983-02-01

    Nuclear medicine instruments are rather sophisticated. They are difficult to maintain in effective working condition, especially in developing countries. The present document describes a survey conducted in Bangladesh, India, Malaysia, Pakistan, Philippines, Singapore, Sri Lanka and Thailand from October 1977 to March 1978, on the use and maintenance of nuclear medicine equipment. The survey evaluated the existing problems of instrument maintenance in the 8 countries visited. The major instruments in use were (1) scintillation probe counters, (2) well scintillation counters and (3) rectilinear cameras. Gamma camera was not widely available in the region at the time of the survey. Most of the surveyed instruments were kept in a detrimental environment resulting in a high failure rate, that caused the relatively high instrument unavailability of 11%. Insufficient bureaucratic handling of repair cases, difficulties with the supply of spare- and replacement parts and lack of training proved to be the main reasons for long periods of instrument inoperation. Remedial actions, based on the survey data, have been initiated

  8. An efficient network for interconnecting remote monitoring instruments and computers

    International Nuclear Information System (INIS)

    Halbig, J.K.; Gainer, K.E.; Klosterbuer, S.F.

    1994-01-01

    Remote monitoring instrumentation must be connected with computers and other instruments. The cost and intrusiveness of installing cables in new and existing plants presents problems for the facility and the International Atomic Energy Agency (IAEA). The authors have tested a network that could accomplish this interconnection using mass-produced commercial components developed for use in industrial applications. Unlike components in the hardware of most networks, the components--manufactured and distributed in North America, Europe, and Asia--lend themselves to small and low-powered applications. The heart of the network is a chip with three microprocessors and proprietary network software contained in Read Only Memory. In addition to all nonuser levels of protocol, the software also contains message authentication capabilities. This chip can be interfaced to a variety of transmission media, for example, RS-485 lines, fiber topic cables, rf waves, and standard ac power lines. The use of power lines as the transmission medium in a facility could significantly reduce cabling costs

  9. Review of techniques and detectors used in instruments for field measurement of β doses and dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1984-01-01

    Generally, field measurements are required to assess the hazard from β-rays before personnel are allowed to occupy a working space or perform a task. Occasionally, the measurements are required for an assessment after a β-ray exposure is suspected to have occurred. With these uses of field instruments in mind, the following detectors and associated techniques will be discussed in terms of the measurement principles, advantages, and limitations: 1) thin-walled ion chambers (sometimes in combination with thick-walled ones or with covers thick enough to prevent penetration of β-particles); 2) thin scintillators, nearly tissue equivalent, to provide a detector analogous to skin; 3) scintillators, thick enough to absorb all the energy of the β-particles. Circuitry is required to count pulses according to size to permit calculation of dose or dose rate; 4) silicon diodes with thin detection layers operated as photocurrent generators; 5) silicon diodes, reversed biassed, with pulses counted according to size; 6) simple pulse counters (e.g., GM counters or silicon diodes with thin windows)

  10. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid P

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''P''. The Appendices contains copies of the printouts of these software programs

  11. Instrumentation and Controls Division progress report, July 1, 1990--June 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    This report contains the following information from the Instrumentation and Controls Division of Oak Ridge National Laboratory: supplementary activities; seminars; publications and presentations; scientific and professional activities, achievements, and awards; and division organization charts.

  12. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  13. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  14. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  15. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load

    Science.gov (United States)

    Klepsch, Melina; Schmitz, Florian; Seufert, Tina

    2017-01-01

    Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 (N = 97), we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1) Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2) Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study (N = between 65 and 95 for each task), we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results. PMID:29201011

  16. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load.

    Science.gov (United States)

    Klepsch, Melina; Schmitz, Florian; Seufert, Tina

    2017-01-01

    Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 ( N = 97), we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1) Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2) Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study ( N = between 65 and 95 for each task), we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results.

  17. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load

    Directory of Open Access Journals (Sweden)

    Melina Klepsch

    2017-11-01

    Full Text Available Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 (N = 97, we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1 Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2 Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study (N = between 65 and 95 for each task, we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results.

  18. Portable instrument for selectively detecting alpha-particles derived from radon

    International Nuclear Information System (INIS)

    Chapuis, A.M.; DaJlevic, D.

    1975-01-01

    A portable instrument of the pocket type designed primarily for monitoring atmospheric contamination in uranium mines by selectively detecting the α-particles emitted simultaneously by the daughter products of radon, namely radium A and radium C' is described. The instrument comprises in combination a tube containing a suction fan for drawing external air through a filter which retains the α-emitting aerosols, a detector in which the α-particles corresponding to the respective energies of the α-emissions of radium A and of radium C' are detected separately, and two collimators placed between the filter and the detector

  19. Comparison of O2 saturation, heart and respiratory rate following injection of vasoconstrictor containing anesthetic (lidocaine 2% and without vasoconstrictor anesthetic (Mepivacaine

    Directory of Open Access Journals (Sweden)

    Bayat M.

    2005-07-01

    Full Text Available Background and Aim: Along with higher usage of dental local anesthesia with risks to people health together with their positive role, the important goal of dentistry, patients’ health, has been stressed repeatedly nowadays. This study was conducted to compare O2 saturation, respiratory rate and heart rate of patients following injection of anesthetic containing vasoconstrictor (lidocaine 2% and without vasoconstrictor (Mepivacaine. Materials and Methods: This experimental study was conducted on 32 healthy humans (16 females and 16 males with 25-50 years age range and no history of drug usage. Cases were classified into two matched groups. O2 saturation, heart and respiratory rate were recorded before extraction of a mandibular posterior tooth. In the first group, 3.6 ml lidocaine 2% with 1:80,000 epinephrine and in the second group Mepivacaine 3% was injected, using inferior alveolar dental nerve block with aspiration. Variables were measured and recorded. Tooth extraction was performed and the mentioned variables were recorded again. Data were analyzed with SPSS software using t and Paired t-test with P<0.05 as the limit of significance. Results: After injection of lidocaine, the heart rate was increased (12.25±1.75 bpm, and the time to reach the maximum rate was 64.75±11.26 seconds. After extraction of tooth, heart rate in both groups was increased not considering the type of injection. Conclusion: The study showed that the injection of lidocaine (containing epinephrine in patients without contraindication has no risk. Also, possible increase in heart rate is not risky and is not associated with O2 saturation decrease and respiratory interruption.

  20. Core outcome measurement instruments for clinical trials in non-specific low back pain

    DEFF Research Database (Denmark)

    Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A

    2017-01-01

    Disability Index version 2.1a (ODI 2.1a) for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In Round 2...... COSMIN methodology. Researchers, clinicians and patients (n = 207) were invited in a two-round Delphi survey to generate consensus ( ≥ 67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In Round 1, consensus was achieved on the Oswestry......, consensus was reached on a NRS version with a 1-week recall period (96% agreement). Various participants requested one free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: ODI 2.1a or 24-item Roland-Morris Disability Questionnaire...

  1. The Popeye domain containing genes: essential elements in heart rate control.

    Science.gov (United States)

    Schindler, Roland F; Poon, Kar Lai; Simrick, Subreena; Brand, Thomas

    2012-12-01

    The Popeye domain containing (Popdc) gene family displays preferential expression in skeletal muscle and heart. Only recently a significant gain in the understanding of the function of Popdc genes in the heart has been obtained. The Popdc genes encode membrane proteins harboring an evolutionary conserved Popeye domain, which functions as a binding domain for cyclic adenosine monophosphate (cAMP). Popdc proteins interact with the two-pore channel TREK-1 and enhance its current. This protein interaction is modulated by cAMP. Null mutations of members of the Popdc gene family in zebrafish and mouse are associated with severe cardiac arrhythmia phenotypes. While in zebrafish an atrioventricular block was prevalent, in mouse a stress-induced sinus bradycardia was observed, which was due to the presence of sinus pauses. Moreover, the phenotype develops in an age-dependent manner, being absent in the young animal and becoming increasingly severe, as the animals grow older. This phenotype is reminiscent of the sick sinus syndrome (SSS), which affects mostly the elderly and is characterized by the poor ability of the cardiac pacemaker to adapt the heart rate to the physiological demand. While being a prevalent disease, which is responsible for a large fraction of pacemaker implantations in Western countries, SSS is poorly understood at the molecular level. It is therefore expected that the study of the molecular basis of the stress-induced bradycardia in Popdc mice will shed new light on the etiology of pacemaker disease.

  2. Instrumentation for two-phase flow measurements in code verification experiments

    International Nuclear Information System (INIS)

    Fincke, J.R.; Anderson, J.L.; Arave, A.E.; Deason, V.A.; Lassahn, G.D.; Goodrich, L.D.; Colson, J.B.; Fickas, E.T.

    1981-01-01

    The development of instrumentation and techniques for the measurement of mass flow rate in two-phase flows conducted at the Idaho National Engineering Laboratory during the past year is briefly described. Instruments discussed are the modular drag-disc turbine transducer, the gamma densitometers, the ultrasonic densitometer, Pitot tubes, and full-flow drag screens. Steady state air-water and transient steam-water data are presented

  3. Effect of free swirl flow on the rate of mass and heat transfer at the bottom of a vertical cylindrical container and possible applications

    International Nuclear Information System (INIS)

    Konsowa, A.H.; Abdel-Aziz, M.H.; Abdo, M.S.E.; Hassan, M.S.; Sedahmed, G.H.

    2017-01-01

    Highlights: • Mass transfer at the bottom of a cylindrical container was studied under decaying swirl flow. • Parameters studied are swirl flow velocity, diameter of the inlet nozzle and solution properties. • A dimensionless equation was obtained using the significant parameters. • The present results were compared with the results obtained using perpendicular inlet nozzle. • Relevance of study to the design of membrane processes was highlighted. - Abstract: Rates of mass transfer at the base of a vertical cylindrical container were determined under decaying swirl flow by the electrochemical technique. Variables studied were swirl flow solution velocity, diameter of the tangential inlet nozzle and physical properties of the solution. The data were correlated by a dimensionless mass transfer equation. The equation can be used to predict the rate of heat loss from the bottom of swirl flow equipment as well as the rate of diffusion controlled corrosion of the bottom. The importance of the derived equation in the design and scale up of a cylindrical batch recirculating catalytic or electrochemical reactor with a catalyst layer or electrode at the bottom and a cooling jacket around the vertical wall suitable for conducting exothermic liquid – solid diffusion controlled reactions which need rapid temperature control to avoid the loss of heat sensitive catalysts or heat sensitive products was pointed out. Comparison of the present results with the results obtained using perpendicular inlet nozzle which generates parallel flow at the bottom and axial flow along the cylindrical container revealed the fact that although swirl flow produces higher rates of heat and mass transfer at the cylindrical wall than axial flow and the reverse is true at the container base. Relevance of the present study to the design and operation of membrane processes and heat recovery from hot pools of liquid metals and low melting alloys in the production stage was highlighted.

  4. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid ''M''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs

  5. Quality of prenatal care questionnaire: instrument development and testing.

    Science.gov (United States)

    Heaman, Maureen I; Sword, Wendy A; Akhtar-Danesh, Noori; Bradford, Amanda; Tough, Suzanne; Janssen, Patricia A; Young, David C; Kingston, Dawn A; Hutton, Eileen K; Helewa, Michael E

    2014-06-03

    Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women's ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the "Support and Respect" subscale of the QPCQ and the "Respectfulness/Emotional Support" subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach's alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women's ratings of their quality of prenatal care did not change as a result of giving birth or between the early postpartum

  6. Quality of prenatal care questionnaire: instrument development and testing

    Science.gov (United States)

    2014-01-01

    Background Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Methods Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Results Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women’s ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the “Support and Respect” subscale of the QPCQ and the “Respectfulness/Emotional Support” subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach’s alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women’s ratings of their quality of prenatal care did not change as a result of giving

  7. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  8. Containment pressure monitoring method after severe accident in nuclear power plant

    International Nuclear Information System (INIS)

    Luo Chuanjie; Zhang Shishui

    2011-01-01

    The containment atmosphere monitoring system in nuclear power plant was designed on the basis of design accident. But containment pressure will increase greatly in a severe accident, and pressure instrument in the containment can't satisfy the monitoring requirement. A new method to monitor the pressure change in the containment after a severe accident was considered, through which accident soften methods can be adopted. Under present technical condition, adding a pressure monitoring channel out of containment for post-severe accident is a considerable method. Daya Bay Nuclear Power Plant implemented this modification, by which the containment release time can be delayed during severe accident, and nuclear safety can be increased. After analysis, this method is safe and feasible. (authors)

  9. Intrajudge and Interjudge Reliability of the Stuttering Severity Instrument-Fourth Edition.

    Science.gov (United States)

    Davidow, Jason H; Scott, Kathleen A

    2017-11-08

    The Stuttering Severity Instrument (SSI) is a tool used to measure the severity of stuttering. Previous versions of the instrument have known limitations (e.g., Lewis, 1995). The present study examined the intra- and interjudge reliability of the newest version, the Stuttering Severity Instrument-Fourth Edition (SSI-4) (Riley, 2009). Twelve judges who were trained on the SSI-4 protocol participated. Judges collected SSI-4 data while viewing 4 videos of adults who stutter at Time 1 and 4 weeks later at Time 2. Data were analyzed for intra- and interjudge reliability of the SSI-4 subscores (for Frequency, Duration, and Physical Concomitants), total score, and final severity rating. Intra- and interjudge reliability across the subscores and total score concurred with the manual's reported reliability when reliability was calculated using the methods described in the manual. New calculations of judge agreement produced different values from those in the manual-for the 3 subscores, total score, and final severity rating-and provided data absent from the manual. Clinicians and researchers who use the SSI-4 should carefully consider the limitations of the instrument. Investigation into the multitasking demands of the instrument may provide information on whether separating the collection of data for specific variables will improve intra- and interjudge reliability of those variables.

  10. [Treatment of a fractured endodontical instrument in the root canal].

    Science.gov (United States)

    Schipper, M; Peters, L B

    2015-12-01

    A 53-year-old woman with continuing pain coming from a lower first molar was diagnosed with apical periodontitis, with a retained fractured instrument in the root canal. There are a variety of treatment options for dealing with a corpus alienum in a root canal. In this case it was decided to treat the tooth endodontically, and leave the fractured instrument fragment in situ. The selection of this treatment option was made on the basis of knowledge of the original diagnosis and the success rates of the various treatment options as described in the relevant literature, weighed against the possible risks and their effects on the prognosis. This suggested that the use of a dental operating microscope has a positive impact on the success rates of endodontic treatment The prognosis for endodontic treatment when a fractured instrument fragment is left within the root canal, as in this case, is not significantly reduced. The presence of preoperative periapical pathology, however, is a more clinically significant prognostic indicator.

  11. Measurement of sexual functioning after spinal cord injury: preferred instruments

    DEFF Research Database (Denmark)

    Alexander, Marcalee Sipski; Brackett, Nancy L; Bodner, Donald

    2009-01-01

    into male and female sexual function, male reproductive function, and female reproductive function. The instruments that have been used most frequently to measure these aspects of sexual function over the past 5 years were identified by expert consensus. Finally, these instruments were subjected...... to a critical review. RESULTS: The Female Sexual Function Index (FSFI), measurement of vaginal pulse amplitude (VPA), the International Index of Erectile Function (IIEF), and the measurement of ejaculatory function and semen quality were considered appropriate measures to assess sexual responses......BACKGROUND/OBJECTIVE: To determine the utility of certain instruments to assess sexuality and fertility after SCI, an expert panel identified key areas to study and evaluated available instruments. These were rated according to certain predefined criteria. METHODS: The authors divided sexual issues...

  12. Neutron scattering instrumentation. A guide to future directions

    International Nuclear Information System (INIS)

    Crawford, R.K.

    2001-01-01

    Many of the neutron scattering instruments being designed or built now are the first generation of pulsed source instruments to provide nearly optimal scattering angle coverage with good spatial resolution in a single setting of the instrument while making full use of modern optics to maximize the useful flux on the sample. Spectacular gains have resulted from such optimization, but in most of these cases there is little room for further large improvements. However, other types of pulsed source instruments are currently less well optimized, and there is room for significant improvements in these types of pulsed source instruments. Several examples will illustrate these points. In the longer term, we can expect source strengths to continue to increase, but only slowly. However, we can expect new science and new ways of doing experiments to emerge. Many of these changes will be driven by enhancements in sample environment capabilities leading to more innovative sample conditions and to efficient parametric studies. Kinetic studies and parametric studies will take on much greater roles with the high data rates now available. Implications of these trends will be discussed. (author)

  13. Neutrons and music: Imaging investigation of ancient wind musical instruments

    Energy Technology Data Exchange (ETDEWEB)

    Festa, G., E-mail: giulia.festa@roma2.infn.it [Università degli Studi di Roma Tor Vergata (Italy); Università degli Studi di Milano-Bicocca (Italy); Consiglio Nazionale delle Ricerche-IPCF, Messina (Italy); Tardino, G. [BauArt Basel, Basel (Switzerland); Pontecorvo, L. [Conservatorio di Cosenza – Cosenza Conservatory (Italy); Mannes, D.C. [Paul Scherrer Institut, Villigen (Switzerland); Senesi, R. [Università degli Studi di Roma Tor Vergata (Italy); Consiglio Nazionale delle Ricerche-IPCF, Messina (Italy); Gorini, G. [Università degli Studi di Milano-Bicocca (Italy); Andreani, C. [Università degli Studi di Roma Tor Vergata (Italy); Consiglio Nazionale delle Ricerche-IPCF, Messina (Italy)

    2014-10-01

    A set of seven musical instruments and two instruments cares from the ‘Fondo Antico della Biblioteca del Sacro Convento’ in Assisi, Italy, were investigated through neutron and X-ray imaging techniques. Historical and scientific interests around ancient musical instruments motivate an intense research effort for their characterization using non-destructive and non-invasive techniques. X-ray and neutron tomography/radiography were applied to the study of composite material samples containing wood, hide and metals. The study was carried out at the NEUTRA beamline, PSI (Paul Scherrer Institute, Switzerland). Results of the measurements provided new information on the composite and multi-scale structure, such as: the internal structure of the samples, position of added materials like metals, wood fiber displays, deformations, presence of adhesives and their spatial distribution and novel insight about construction methods to guide the instruments’ restoration process.

  14. Neutrons and music: Imaging investigation of ancient wind musical instruments

    International Nuclear Information System (INIS)

    Festa, G.; Tardino, G.; Pontecorvo, L.; Mannes, D.C.; Senesi, R.; Gorini, G.; Andreani, C.

    2014-01-01

    A set of seven musical instruments and two instruments cares from the ‘Fondo Antico della Biblioteca del Sacro Convento’ in Assisi, Italy, were investigated through neutron and X-ray imaging techniques. Historical and scientific interests around ancient musical instruments motivate an intense research effort for their characterization using non-destructive and non-invasive techniques. X-ray and neutron tomography/radiography were applied to the study of composite material samples containing wood, hide and metals. The study was carried out at the NEUTRA beamline, PSI (Paul Scherrer Institute, Switzerland). Results of the measurements provided new information on the composite and multi-scale structure, such as: the internal structure of the samples, position of added materials like metals, wood fiber displays, deformations, presence of adhesives and their spatial distribution and novel insight about construction methods to guide the instruments’ restoration process

  15. The preparation of synthetic standards for use in instrumental neutron-activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Watterson, J.I.W.; Erasmus, C.S.

    1979-01-01

    An account is given of the formulation and preparation of synthetic standards suitable for the routine analysis of minerals, ores, and ore concentrates by instrumental neutron activation. Fifteen standards were prepared, each containing from one to seven elements. The standards contain forty-four elements that produce isotopes with half-lives longer than 12 hours. An evaluation of the accuracy and precision of the method of preparation is given

  16. 21 CFR 864.3250 - Specimen transport and storage container.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Specimen transport and storage container. 864.3250 Section 864.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864...

  17. Development and testing of the circumvaginal muscles rating scale.

    Science.gov (United States)

    Worth, A M; Dougherty, M C; McKey, P L

    1986-01-01

    The purpose of this research was to develop an instrument for clinical assessment of the circumvaginal muscles (CVM), to test the reliability of the instrument, and to correlate sample characteristics with this instrument. The 9-point CVM Rating Scale is based on four components: pressure, duration, muscle ribbing, and position of the examiner's finger during examination. Reliability of the CVM Rating Scale was ascertained by use of interrater and test-retest reliability. Interrater reliability was tested on two separate occasions, N = 10, rho = 0.6, p less than .04; N = 10, rho = 0.7, p less than .05. A test-retest sequence was conducted 10 days apart, N = 10, rho = 0.9, p less than .003. Results from these tests indicated that the CVM Rating Scale is a reliable instrument for assessing CVM. A convenience sample of 30 women, aged 18-37, in good general health was tested, using the CVM Rating Scale. Women with a history of pelvic floor reconstructive surgery were excluded. A significant positive correlation between self-reported orgasm and the CVM Rating Scale total scores was found, chi 2 = 7.5, p less than .02. No significant correlations were found between age, race, parity, episiotomy, or self-reported Kegel exercises and the CVM Rating Scale total scores. The scale is a cost-effective, time-efficient, systematic assessment, accessible in clinical settings.

  18. Comparison between continuous and localized methods to evaluate the flow rate through containment concrete structures

    Energy Technology Data Exchange (ETDEWEB)

    Jason, L., E-mail: ludovic.jason@cea.fr [Atomic Energy Commission (CEA), DEN, DANS, DM2S, SEMT, Mechanics and System Simulation Laboratory (LM2S), F-91191 Gif sur Yvette (France); LaMSID, UMR CNRS-EDF-CEA 8193, F-92141 Clamart (France); Masson, B. [Electricité de France (EDF), SEPTEN, F-69628 Villeurbanne (France)

    2014-10-01

    Highlights: • The contribution focuses on the gas transfer through reinforced concrete structures. • A continuous approach with a damage–permeability law is investigated. • It is significant, for this case, only when the damage variable crosses the section. • In this case, two localized approaches are compared. • It helps at evaluating a “reference” crack opening for engineering laws. - Abstract: In this contribution, different techniques are compared to evaluate the gas flow rate through a representative section of a reinforced and prestressed concrete containment structure. A continuous approach is first applied which is based on the evaluation of the gas permeability as a function of the damage variable. The calculations show that the flow rate becomes significant only when the damage variable crosses the section. But in this situation, the continuous approach is no longer fully valid. That is why localized approaches, based on a fine description of the crack openings, are then investigated. A comparison between classical simplified laws (Poiseuille flow) and a more refined model which takes into account the evolution of the crack opening in the depth of the section enables to define the validity domain of the simplified laws and especially the definition of the associated “reference opening”.

  19. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  20. Taxing land for urban containment : Reflections on a Dutch debate

    NARCIS (Netherlands)

    Korthals Altes, W.K.

    2009-01-01

    Excessive land use regulations aimed at containing urban sprawl have been criticised, because they may overcompensate for the external effects of uncontrolled greenfield development and contribute to stagnation in house building. Taxes on building in green spaces may be an instrument for balancing

  1. Instrument lance for boiling water reactors

    International Nuclear Information System (INIS)

    Proell, N.; Bertz, S.; Graebener, K.H.

    1980-01-01

    The instrument lance contains in the lance cover pipe a thimble as part of the drive chamber system. Other thimbles serve to carry neutron detectors. Detectors can be exchanged without opening the reactor pressure vessel and without removing the fuel elements. Furthermore the detector exchange is independent from the fuel element cycle. The measurement lance passes from the bottom of the pressure vessel over the total hight of the core in the water ducts between the fuel elements and can thus determine the neutron flux distribution. (DG) [de

  2. The XRF spectrometer and the selection of analysis conditions (instrumental variables)

    International Nuclear Information System (INIS)

    Willis, J.P.

    2002-01-01

    Full text: This presentation will begin with a brief discussion of EDXRF and flat- and curved-crystal WDXRF spectrometers, contrasting the major differences between the three types. The remainder of the presentation will contain a detailed overview of the choice and settings of the many instrumental variables contained in a modern WDXRF spectrometer, and will discuss critically the choices facing the analyst in setting up a WDXRF spectrometer for different elements and applications. In particular it will discuss the choice of tube target (when a choice is possible), the kV and mA settings, tube filters, collimator masks, collimators, analyzing crystals, secondary collimators, detectors, pulse height selection, X-ray path medium (air, nitrogen, vacuum or helium), counting times for peak and background positions and their effect on counting statistics and lower limit of detection (LLD). The use of Figure of Merit (FOM) calculations to objectively choose the best combination of instrumental variables also will be discussed. This presentation will be followed by a shorter session on a subsequent day entitled - A Selection of XRF Conditions - Practical Session, where participants will be given the opportunity to discuss in groups the selection of the best instrumental variables for three very diverse applications. Copyright (2002) Australian X-ray Analytical Association Inc

  3. Cutting efficiency of Reciproc and waveOne reciprocating instruments.

    Science.gov (United States)

    Plotino, Gianluca; Giansiracusa Rubini, Alessio; Grande, Nicola M; Testarelli, Luca; Gambarini, Gianluca

    2014-08-01

    The aim of the present study was to evaluate the cutting efficiency of 2 new reciprocating instruments, Reciproc and WaveOne. Twenty-four new Reciproc R25 and 24 new WaveOne Primary files were activated by using a torque-controlled motor (Silver Reciproc) and divided into 4 groups (n = 12): group 1, Reciproc activated by Reciproc ALL program; group 2, Reciproc activated by WaveOne ALL program; group 3, WaveOne activated by Reciproc ALL program; and group 4, WaveOne activated by WaveOne ALL program. The device used for the cutting test consisted of a main frame to which a mobile plastic support for the handpiece is connected and a stainless steel block containing a Plexiglas block (inPlexiglass, Rome, Italy) against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1 mm. Means and standard deviations of each group were calculated, and data were statistically analyzed with 1-way analysis of variance and Bonferroni test (P cutting efficiency than WaveOne Primary for both the movements used (P cutting efficiency than WaveOne instruments used with their proper reciprocating motion (P .05). Reciproc instruments demonstrated statistically higher cutting efficiency than WaveOne instruments. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Varying ultrasound power level to distinguish surgical instruments and tissue.

    Science.gov (United States)

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  5. Development and Reliability Evaluation of the Movement Rating Instrument for Virtual Reality Video Game Play.

    Science.gov (United States)

    Levac, Danielle; Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi

    2016-06-01

    Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI

  6. The Development and Evaluation of a Novel Instrument Assessing Residents' Discharge Summaries.

    Science.gov (United States)

    Hommos, Musab S; Kuperman, Ethan F; Kamath, Aparna; Kreiter, Clarence D

    2017-04-01

    To develop and determine the reliability of a novel measurement instrument assessing the quality of residents' discharge summaries. In 2014, the authors created a discharge summary evaluation instrument based on consensus recommendations from national regulatory bodies and input from primary care providers at their institution. After a brief pilot, they used the instrument to evaluate discharge summaries written by first-year internal medicine residents (n = 24) at a single U.S. teaching hospital during the 2013-2014 academic year. They conducted a generalizability study to determine the reliability of the instrument and a series of decision studies to determine the number of discharge summaries and raters needed to achieve a reliable evaluation score. The generalizability study demonstrated that 37% of the variance reflected residents' ability to generate an adequate discharge summary (true score variance). The decision studies estimated that the mean score from six discharge summary reviews completed by a unique rater for each review would yield a reliability coefficient of 0.75. Because of high interrater reliability, multiple raters per discharge summary would not significantly enhance the reliability of the mean rating. This evaluation instrument reliably measured residents' performance writing discharge summaries. A single rating of six discharge summaries can achieve a reliable mean evaluation score. Using this instrument is feasible even for programs with a limited number of inpatient encounters and a small pool of faculty preceptors.

  7. NPP containment pre-stress loss - summary statement

    International Nuclear Information System (INIS)

    1999-01-01

    monitoring of the behaviour of containments and pressure vessels at operational plant assist our understanding of the cause of loss of prestress. Containments around the world include instruments to measure: anchorage loads; concrete strain; structural geometry; concrete temperature; and surface cracking. Data collected from more than 150 structures aged between 3 and 40 years indicate that, for the majority, loss of prestress has been less than predicted. However, for some containments, losses have exceeded predictions. Measured losses vary from containment design to containment design but significant differences have also been observed between containments in the same design series. The variation in measured losses has been attributed to a number of factors including: concrete composition; aggregate type; the presence of a liner; high relaxation of steel tendons; concrete temperatures; loading history and the environment. Regulatory and codified prediction techniques do not necessarily account for such factors. Many plant include direct measurement of tendon loads at the anchorage. A number of papers reported problems with the reliability and accuracy of tendon load measurement. The use of tendon load to interpret loss of prestress requires careful consideration of the method used to measure the load and the design of the prestressing system. Nuclear containments and pressure vessels are designed with large margins on structural integrity. Therefore, a higher than expected loss of prestress does not necessarily jeopardise the integrity of the structure. However, under accident conditions the margin on pre-compression of the concrete is reduced and therefore there is an increased risk of cracking. This may result in a corresponding increase in the leak rate of unlined containments. Periodic testing of the containment is used to evaluate its leak-tightness. The workshop discussed the corrosion protection media used for containments and pressure vessels having un

  8. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-14

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs.

  9. Problems in instrumentation for S-odorant emissions

    International Nuclear Information System (INIS)

    Hall, H.J.

    1974-01-01

    Instrumentation to measure sulfur-containing odorants in stack emissions is much more difficult than in the ambient atmosphere, and must be matched to the specific source: key components aside from H 2 S are methyl mercaptan in paper mills, COS/CS 2 in a refinery Claus plant, and SO 2 /SO 3 in a combustion stack. Satisfactory operation for a period of six months was not achieved by any instrument in this service, in a lab and field evaluation of eight instruments of three types commercially available as of 1971. The effects of interferent gases H 2 O, SO 2 , CO 2 /CO and particulates which are diluted in ambient samples are greatly aggravated in stack gases, where the ratio of odorant to interferent may be 1:1000 or less, due to the very great sensitivity of human receptors to S-odorants. The most serious problem proved to be the analysis for odorless carbonyl sulfide, which is commonly formed where S compounds are oxidized in a reducing atmosphere. This COS has been undetected or mistaken for odorous H 2 S in most analyses. A field instrument for the general case would provide exactly simultaneous readings at five minute intervals or less for the five components H 2 S, SO 2 , COS, CSH, and total S, or their equivalent. This may be simplified to four components or less only when the composition of the sample gas is positively known

  10. N Basin deactivation high exposure rate hardware container offgassing final report

    International Nuclear Information System (INIS)

    Day, R.S.; Palmer, D.L.; Pisarcik, D.J.; Vail, S.W.

    1996-11-01

    The N Reactor's 105-N Basin (N Basin) and the methods of packaging high-exposure rate hardware (HERH) were inspected, and gas bubbles were observed rising from the top surface of the third monolith prepared, Monolith No. 3. The HERH packaging was discontinued until the gas and the source could be explained and the safety of continued operation was verified. This report documents the investigation and the conclusions that support decisions regarding N Basin water removal, future storage, shipping, and Monolith No. 3 burial. Samples indicate that the gas emitted from Monolith No. 3 is almost exclusively hydrogen, containing some air and trace quantities of stable xenon. Gamma-energy analysis indicated trace amounts of 85 Kr in the samples. The literature review and the laboratory test results support the conclusion that aluminum is the only potentially grouted metal capable of corroding rapidly enough to generate the quantities of hydrogen gas that are observed. Based on aluminum components known to be found in the N Basin, the likely source of the aluminum is a used aluminum rupture can. All gas pockets in Monolith No. 3 caused by offgassing should be vented to the surface of the monolith. The peak offgas pressure within Monolith No. 3 (after it is removed from the N Basin water) should be approximately 0.62 psi above atmospheric pressure. Sufficient testing and analysis has been completed to remove Monolith No. 3 from the N Basin water and place the monolith in temporary storage until arrangements have been made for its shipment and disposition

  11. Effect of food on immature development, consumption rate, and relative growth rate of Toxorhynchites splendens (Diptera: Culicidae, a predator of container breeding mosquitoes

    Directory of Open Access Journals (Sweden)

    D Dominic Amalraj

    2005-12-01

    Full Text Available Food utilization by the larvae of Toxorhynchites splendens (Wiedemann was studied in the laboratory by offering larvae of Aedes aegypti Linnaeus, Anopheles stephensi (Liston, and Culex quinquefasciatus (Say. Quantitative analyses of data indicated that immature development was significantly faster with increase in food availability. The regression analysis showed that the degrees of the relationship between immature duration (Id and food availability were higher when offered early instars of prey (first and second instars than late instars. Consumption rate (Cr of the predator increased with increase in food availability and this relationship was highly significant when larvae of An. stephensi were offered as food. Consumption rate to food level decreased with increase in the age class of the prey. There was a significant negative correlation between Id and Cr. This aspect helps to increase population turnover of T. splendens in a shorter period when the prey is abundant. Conversely, the predator compensated the loss in daily food intake at low food level by extending Id thereby attains the minimum threshold pupal weight for adult emergence. There was an increase in the relative growth rate (RGR of the predator when An. stephensi was offered as prey and this was related to the high protein content of the prey per body weight. There was a positive correlation between Cr and RGR. This adaptive life characteristic strategy of this predator is useful for mass-rearing for large scale field release programmes in the control of container breeding mosquitoes is discussed.

  12. 24 CFR 232.560 - Interest rate.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Interest rate. 232.560 Section 232... Equipment Eligible Security Instruments § 232.560 Interest rate. (a) The loan shall bear interest at the rate agreed upon by the lender and the borrower. (b) Interest shall be payable in monthly installments...

  13. Hydrogen behavior in ice condenser containments

    Energy Technology Data Exchange (ETDEWEB)

    Lundstroem, P.; Hongisto, O. [Power Plant Lab., Helsinki (Finland); Theofanous, T.G. [Univ. of California, Santa Barbara, CA (United States)] [and others

    1995-09-01

    A new hydrogen management strategy is being developed for the Loviisa ice condenser containment. The strategy relies on containment-wide natural circulations that develop, once the ice condenser doors are forced open, to effectively produce a well-mixed behavior, and a correspondingly slow rise in hydrogen concentration. Levels can then be kept low by a distributed catalytic recombiner system, and (perhaps) an igniter system as a backup, while the associated energy releases can be effectively dissipated in the ice bed. Verification and fine-tuning of the approach is carried out experimentally in the VICTORIA facility and by associated scaling/modelling studies. VICTORIA represents an 1/15th scale model of the Loviisa containment, hydrogen is simulated by helium, and local concentration measurements are obtained by a newly developed instrument specifically for this purpose, called SPARTA. This paper is focused on experimental results from several key experiments that provide a first delineation of key behaviors.

  14. Design of a TOF-SANS instrument for the proposed long wavelength target station at the spallation neutron source

    International Nuclear Information System (INIS)

    Thiyagarajan, P.; Littrell, K.; Seeger, P.A.

    2001-01-01

    We have designed a versatile high-throughput SANS instrument [Broad Range Intense Multipurpose SANS (BRIMS)] for the proposed Long Wavelength Target Station at the SNS by using acceptance diagrams and the Los Alamos NISP Monte Carlo simulation package. This instrument has been fully optimized to take advantage of the 10 Hz source frequency (broad wavelength bandwidth) and the cold neutron spectrum from a tall coupled solid methane moderator (12 cm x 20 cm). BRIMS has been designed to produce data in a Q range spanning from 0.0025 to 0.7 A -1 in a single measurement by simultaneously using neutrons with wavelengths ranging from 1 to 14.5 A in a time of flight mode. A supermirror guide and bender assembly is employed to separate and redirect the useful portion of the neutron spectrum with λ>1 A, by 2.3deg away from the direct beam containing high energy neutrons and γ rays. The effects of various collimation choices on count rate, resolution and Q min have been characterized using spherical particle and delta function scatterers. The overall performance of BRIMS has been compared with that of the best existing reactor-based SANS instrument D22 at ILL. (author)

  15. Safety Evaluation of Kartini Reactor Based on Instrumentation System Design

    International Nuclear Information System (INIS)

    Tjipta Suhaemi; Djen Djen Dj; Itjeu K; Johnny S; Setyono

    2003-01-01

    The safety of Kartini reactor has been evaluated based on instrumentation system aspect. The Kartini reactor is designed by BATAN. Design power of the reactor is 250 kW, but it is currently operated at 100 kW. Instrumentation and control system function is to monitor and control the reactor operation. Instrumentation and control system consists of safety system, start-up and automatic power control, and process information system. The linear power channel and logarithmic power channel are used for measuring power. There are 3 types of control rod for controlling the power, i.e. safety rod, shim rod, and regulating rod. The trip and interlock system are used for safety. There are instrumentation equipment used for measuring radiation exposure, flow rate, temperature and conductivity of fluid The system of Kartini reactor has been developed by introducing a process information system, start-up system, and automatic power control. It is concluded that the instrumentation of Kartini reactor has followed the requirement and standard of IAEA. (author)

  16. Uncertainties in container failure time predictions

    International Nuclear Information System (INIS)

    Williford, R.E.

    1990-01-01

    Stochastic variations in the local chemical environment of a geologic waste repository can cause corresponding variations in container corrosion rates and failure times, and thus in radionuclide release rates. This paper addresses how well the future variations in repository chemistries must be known in order to predict container failure times that are bounded by a finite time period within the repository lifetime. Preliminary results indicate that a 5000 year scatter in predicted container failure times requires that repository chemistries be known to within ±10% over the repository lifetime. These are small uncertainties compared to current estimates. 9 refs., 3 figs

  17. In-pile Instrumentation Development

    International Nuclear Information System (INIS)

    Vermeeren, L.

    2005-01-01

    Advanced irradiations in research reactors require the on-line monitoring of crucial parameters like neutron fluxes, gamma dose rates, central fuel rod temperatures, fission gas release pressures and small geometry changes. Our activities in this field aim at a detailed understanding of the sensor behaviour in the irradiation conditions in order to extract reliable real-time information. The objectives of work performed by SCK-CEN are to study of the on-line in-pile measurement of gamma and neutron fluxes in real time and to investigate parasitic radiation-induced signals in instrumentation cables

  18. Outcomes of moral case deliberation--the development of an evaluation instrument for clinical ethics support (the Euro-MCD).

    Science.gov (United States)

    Svantesson, Mia; Karlsson, Jan; Boitte, Pierre; Schildman, Jan; Dauwerse, Linda; Widdershoven, Guy; Pedersen, Reidar; Huisman, Martijn; Molewijk, Bert

    2014-04-08

    Clinical ethics support, in particular Moral Case Deliberation, aims to support health care providers to manage ethically difficult situations. However, there is a lack of evaluation instruments regarding outcomes of clinical ethics support in general and regarding Moral Case Deliberation (MCD) in particular. There also is a lack of clarity and consensuses regarding which MCD outcomes are beneficial. In addition, MCD outcomes might be context-sensitive. Against this background, there is a need for a standardised but flexible outcome evaluation instrument. The aim of this study was to develop a multi-contextual evaluation instrument measuring health care providers' experiences and perceived importance of outcomes of Moral Case Deliberation. A multi-item instrument for assessing outcomes of Moral Case Deliberation (MCD) was constructed through an iterative process, founded on a literature review and modified through a multistep review by ethicists and health care providers. The instrument measures perceived importance of outcomes before and after MCD, as well as experienced outcomes during MCD and in daily work. A purposeful sample of 86 European participants contributed to a Delphi panel and content validity testing. The Delphi panel (n = 13), consisting of ethicists and ethics researchers, participated in three Delphi-rounds. Health care providers (n = 73) participated in the content validity testing through 'think-aloud' interviews and a method using Content Validity Index. The development process resulted in the European Moral Case Deliberation Outcomes Instrument (Euro-MCD), which consists of two sections, one to be completed before a participant's first MCD and the other after completing multiple MCDs. The instrument contains a few open-ended questions and 26 specific items with a corresponding rating/response scale representing various MCD outcomes. The items were categorised into the following six domains: Enhanced emotional support, Enhanced

  19. Outcomes of Moral Case Deliberation - the development of an evaluation instrument for clinical ethics support (the Euro-MCD)

    Science.gov (United States)

    2014-01-01

    Background Clinical ethics support, in particular Moral Case Deliberation, aims to support health care providers to manage ethically difficult situations. However, there is a lack of evaluation instruments regarding outcomes of clinical ethics support in general and regarding Moral Case Deliberation (MCD) in particular. There also is a lack of clarity and consensuses regarding which MCD outcomes are beneficial. In addition, MCD outcomes might be context-sensitive. Against this background, there is a need for a standardised but flexible outcome evaluation instrument. The aim of this study was to develop a multi-contextual evaluation instrument measuring health care providers’ experiences and perceived importance of outcomes of Moral Case Deliberation. Methods A multi-item instrument for assessing outcomes of Moral Case Deliberation (MCD) was constructed through an iterative process, founded on a literature review and modified through a multistep review by ethicists and health care providers. The instrument measures perceived importance of outcomes before and after MCD, as well as experienced outcomes during MCD and in daily work. A purposeful sample of 86 European participants contributed to a Delphi panel and content validity testing. The Delphi panel (n = 13), consisting of ethicists and ethics researchers, participated in three Delphi-rounds. Health care providers (n = 73) participated in the content validity testing through ‘think-aloud’ interviews and a method using Content Validity Index. Results The development process resulted in the European Moral Case Deliberation Outcomes Instrument (Euro-MCD), which consists of two sections, one to be completed before a participant’s first MCD and the other after completing multiple MCDs. The instrument contains a few open-ended questions and 26 specific items with a corresponding rating/response scale representing various MCD outcomes. The items were categorised into the following six domains: Enhanced

  20. Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use.

    Science.gov (United States)

    Inan, Ugur; Gonulol, Nihan

    2009-10-01

    In recent years, a number of rotary nickel titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system. Although the NiTi instruments are more flexible than the stainless steel files, the main problem with the rotary NiTi instruments is the failure of the instruments. The aim of this study was to evaluate the deformation and fracture rate of Mtwo rotary nickel-titanium instruments (VDW, Munich, Germany) discarded after routine clinical use. A total of 593 Mtwo rotary NiTi instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, and then all the files were evaluated under a stereomicroscope for defects such as unwinding, curving, or bending and fracture. The fracture faces of separated files were also evaluated under a scanning electron microscope. The data were analyzed using a chi-square and z test. A percentage of all files (25.80%) showed defects, and the major defect was fracture (16.02%). The most frequently fractured file was #10.04 (30.39%). Deformations without fracture were mostly observed on #15.05 files (25.47%). A higher rate of deformation was observed for #10.04 and #15.05 files. Therefore, these files should be considered as single-use instruments. Because cyclic fatigue was the cause of 71.58% of the instrument fractures, it is also important not to exceed the maximum number of usage recommended by the manufacturer and discard the instruments on a regular basis.

  1. Measuring quality in community based housing support - the QPC-H instrument.

    Science.gov (United States)

    Lundqvist, Lars-Olov; Rask, Mikael; Brunt, David; Ivarsson, Ann-Britt; Schröder, Agneta

    2016-04-18

    Purpose - The purpose of this paper is to test the psychometric properties and dimensionality of the instrument Quality in Psychiatric Care-Housing (QPC-H) and briefly describe the residents' perception of quality of housing support. Design/methodology/approach - A sample of 174 residents from 22 housing support services in nine Swedish municipalities participated in the study. Confirmatory factor analysis (CFA) revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the Quality in Psychiatric Care (QPC) family of instruments. Findings - CFA revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the QPC family of instruments. The internal consistency of the factors was acceptable except in the case of secure and secluded environment, probably due to few numbers of items. With this exception, the QPC-H shows adequate psychometric properties. Social implications - The residents' ratings of quality of housing service were generally high; the highest rating was for secluded environment and the lowest for participation. This dimension would thus seem to indicate an important area for improvement. Originality/value - The QPC-H includes important aspects of residents' assessment of quality of housing service and offers a simple and inexpensive way to evaluate housing support services from the residents' perspective.

  2. The Hydraulic Test Procedure for Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan; Park, Chan Kook

    2008-08-15

    This report presents the procedure of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of advanced PWR annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, confirm the flow rate at the 200 kPa pressure drop and measure the RMS displacement at this time. And the endurance test is confirmed the wear and the integrity of the non-instrumented rig at the 110% design flow rate. This out-pile test perform the Flow-Induced Vibration and Pressure Drop Experimental Tester(FIVPET) facility. The instruments in FIVPET facility was calibrated in KAERI and the pump and the thermocouple were certified by manufacturer.

  3. Validation of cross-cultural child mental health and psychosocial research instruments: adapting the Depression Self-Rating Scale and Child PTSD Symptom Scale in Nepal

    Science.gov (United States)

    2011-01-01

    Background The lack of culturally adapted and validated instruments for child mental health and psychosocial support in low and middle-income countries is a barrier to assessing prevalence of mental health problems, evaluating interventions, and determining program cost-effectiveness. Alternative procedures are needed to validate instruments in these settings. Methods Six criteria are proposed to evaluate cross-cultural validity of child mental health instruments: (i) purpose of instrument, (ii) construct measured, (iii) contents of construct, (iv) local idioms employed, (v) structure of response sets, and (vi) comparison with other measurable phenomena. These criteria are applied to transcultural translation and alternative validation for the Depression Self-Rating Scale (DSRS) and Child PTSD Symptom Scale (CPSS) in Nepal, which recently suffered a decade of war including conscription of child soldiers and widespread displacement of youth. Transcultural translation was conducted with Nepali mental health professionals and six focus groups with children (n = 64) aged 11-15 years old. Because of the lack of child mental health professionals in Nepal, a psychosocial counselor performed an alternative validation procedure using psychosocial functioning as a criterion for intervention. The validation sample was 162 children (11-14 years old). The Kiddie-Schedule for Affective Disorders and Schizophrenia (K-SADS) and Global Assessment of Psychosocial Disability (GAPD) were used to derive indication for treatment as the external criterion. Results The instruments displayed moderate to good psychometric properties: DSRS (area under the curve (AUC) = 0.82, sensitivity = 0.71, specificity = 0.81, cutoff score ≥ 14); CPSS (AUC = 0.77, sensitivity = 0.68, specificity = 0.73, cutoff score ≥ 20). The DSRS items with significant discriminant validity were "having energy to complete daily activities" (DSRS.7), "feeling that life is not worth living" (DSRS.10), and "feeling

  4. Validation of cross-cultural child mental health and psychosocial research instruments: adapting the Depression Self-Rating Scale and Child PTSD Symptom Scale in Nepal

    Directory of Open Access Journals (Sweden)

    Tol Wietse A

    2011-08-01

    Full Text Available Abstract Background The lack of culturally adapted and validated instruments for child mental health and psychosocial support in low and middle-income countries is a barrier to assessing prevalence of mental health problems, evaluating interventions, and determining program cost-effectiveness. Alternative procedures are needed to validate instruments in these settings. Methods Six criteria are proposed to evaluate cross-cultural validity of child mental health instruments: (i purpose of instrument, (ii construct measured, (iii contents of construct, (iv local idioms employed, (v structure of response sets, and (vi comparison with other measurable phenomena. These criteria are applied to transcultural translation and alternative validation for the Depression Self-Rating Scale (DSRS and Child PTSD Symptom Scale (CPSS in Nepal, which recently suffered a decade of war including conscription of child soldiers and widespread displacement of youth. Transcultural translation was conducted with Nepali mental health professionals and six focus groups with children (n = 64 aged 11-15 years old. Because of the lack of child mental health professionals in Nepal, a psychosocial counselor performed an alternative validation procedure using psychosocial functioning as a criterion for intervention. The validation sample was 162 children (11-14 years old. The Kiddie-Schedule for Affective Disorders and Schizophrenia (K-SADS and Global Assessment of Psychosocial Disability (GAPD were used to derive indication for treatment as the external criterion. Results The instruments displayed moderate to good psychometric properties: DSRS (area under the curve (AUC = 0.82, sensitivity = 0.71, specificity = 0.81, cutoff score ≥ 14; CPSS (AUC = 0.77, sensitivity = 0.68, specificity = 0.73, cutoff score ≥ 20. The DSRS items with significant discriminant validity were "having energy to complete daily activities" (DSRS.7, "feeling that life is not worth living" (DSRS.10, and

  5. Nuclear Enterprises portable dose rate meter type PDR 2

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    This instrument is a portable battery powered dose rate meter covering the dose rate range from 0.05 to 500 mrad h -1 . It is designed to measure X- and γ-radiation dose rates over the energy range from 35 keV to 3 MeV. The radiation detector is an MX 164/S GM tube provided with a compensation sheath. The report describes the instrument under the headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  6. The Society for Implementation Research Collaboration Instrument Review Project: a methodology to promote rigorous evaluation.

    Science.gov (United States)

    Lewis, Cara C; Stanick, Cameo F; Martinez, Ruben G; Weiner, Bryan J; Kim, Mimi; Barwick, Melanie; Comtois, Katherine A

    2015-01-08

    Identification of psychometrically strong instruments for the field of implementation science is a high priority underscored in a recent National Institutes of Health working meeting (October 2013). Existing instrument reviews are limited in scope, methods, and findings. The Society for Implementation Research Collaboration Instrument Review Project's objectives address these limitations by identifying and applying a unique methodology to conduct a systematic and comprehensive review of quantitative instruments assessing constructs delineated in two of the field's most widely used frameworks, adopt a systematic search process (using standard search strings), and engage an international team of experts to assess the full range of psychometric criteria (reliability, construct and criterion validity). Although this work focuses on implementation of psychosocial interventions in mental health and health-care settings, the methodology and results will likely be useful across a broad spectrum of settings. This effort has culminated in a centralized online open-access repository of instruments depicting graphical head-to-head comparisons of their psychometric properties. This article describes the methodology and preliminary outcomes. The seven stages of the review, synthesis, and evaluation methodology include (1) setting the scope for the review, (2) identifying frameworks to organize and complete the review, (3) generating a search protocol for the literature review of constructs, (4) literature review of specific instruments, (5) development of an evidence-based assessment rating criteria, (6) data extraction and rating instrument quality by a task force of implementation experts to inform knowledge synthesis, and (7) the creation of a website repository. To date, this multi-faceted and collaborative search and synthesis methodology has identified over 420 instruments related to 34 constructs (total 48 including subconstructs) that are relevant to implementation

  7. Penetration of gas into concrete during a leakage rate test of reactor containments and its significance for the drop in pressure

    Directory of Open Access Journals (Sweden)

    Nilsson L.-O.

    2011-04-01

    Full Text Available The objective of the project described in the paper was to develop a simulation model that describes transient air pressure distribution in concrete in order to see if the leakage rates obtained from the Containment Integrated Leakage Rate Tests can be explained by the transient air pressurization of concrete pores inside the steel liner. A partial differential equation was derived which describes transient air pressure distribution in concrete pores. The model was validated against experimental results. The simulation model shows that there are significant air fluxes into the concrete structures that can explain the pressure drop during a leakage test.

  8. Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Guiral, P.; Ribouton, J.; Jalade, P. [Service de Physique Médicale et Radioprotection, Centre Hospitalier Lyon Sud, Pierre-Bénite F-69495 (France); Wang, R.; Galvan, J.-M.; Lu, G.-N.; Pittet, P., E-mail: patrick.pittet@univ-lyon1.fr [Institut des Nanotechnologies de Lyon, University Lyon, Université Claude Bernard Lyon 1, CNRS, INL UMR5270, F-69622 Villeurbanne (France); Rivoire, A.; Gindraux, L. [DOSILAB, 66 Boulevard Niels Bohr, Villeurbanne F-69100 (France)

    2016-09-15

    Purpose: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. Methods: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position–time gamma index is used to monitor the quality of treatment delivery. Results: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position–time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on

  9. Automatic checking of heavy element content in polymetallic ores directly in transportation containers

    International Nuclear Information System (INIS)

    Varvaritsa, V.P.; Mamikon'yan, S.V.; Nagornyj, V.Ya.

    1981-01-01

    An automatic measuring instrument has been developed and used to check rapidly the content of lead in ores transported by trolley cars, dump trucks, dump cars or other open containers. The measuring technique is based on gamma backscattering and X-ray fluorescence. Influences of container movements, volumetric density changes and matrix effects on the achievable accuracy are briefly discussed

  10. Prototype of a Laser-Induced Fluorescence Ground-Based Instrument for Measurements of Atmospheric Iodine Monoxide (IO)

    Science.gov (United States)

    Thurlow, M. E.; Co, D. T.; Hanisco, T. F.; Lapson, L. B.; Anderson, J. G.

    2008-12-01

    High abundances of iodine monoxide (IO) are known to exist and to participate in local photochemistry of the marine boundary layer: (1) IO participates in depletion episodes of O3 and in the removal of mercury in the Arctic polar spring by enhancing atomic Br mixing ratios. Recent observations and computer simulations suggest that mercury sequestration is closely tied to halogen photochemistry and that gaseous atomic Hg depletion can be enhanced significantly by the presence of small amounts of iodine-containing compounds. (2) IO and higher- order iodine oxides are involved in the formation of new particles in coastal marine environments. Studies using smog chamber experiments simulating coastal atmospheric conditions have demonstrated that new particles can form from condensable iodine-containing vapors and that their concentrations over the open ocean are sufficient to influence marine particle formation. (3) IO has also been shown to affect the oxidizing capacity of the troposphere by altering the partitioning of NO2/NO and HO2/HO and by activating chlorine and bromine in sea salt aerosols. In the stratosphere, these same processes can lead to enhanced ozone loss rates. Detailed photochemical models that include iodine photochemistry, however, are hampered by the lack of observational data. The distribution of IO in vertical, horizontal, and temporal coordinates is unknown, so the impact of IO on global photochemistry cannot be predicted. The resolution of these important scientific issues requires an in situ IO instrument. A fully functional nanosecond Nd:YAG-pumped Ti:Sapphire laser system and a prototype IO ground-based instrument have been built in our lab. With the current setup, the laser system was situated 10 m from the field station, and the laser light was coupled via an optical fiber. With the use of highly efficient fluorescence detection optics and photon counting techniques, sensitivities of better than 0.1 ppt in 1 s for IO was achieved in the

  11. Ventilation air conditioner for a reactor container

    International Nuclear Information System (INIS)

    Ikegame, Noboru; Nakagawa, Takeshi.

    1980-01-01

    Purpose: To suppress the variations in the internal pressure of a reactor container and smoothly ventilate the reactor container. Constitution: The air conditioner provides an air-flow-rate-control damper, a purge-air supply fan, and a filter device in the air-supply pipe of a reactor container. Furthermore, it provides a pressure difference detector at a part of the container. The air-flow-rate-control damper is connected electrically through a position-modulator-comparison amplifier to the pressure difference detector. When the filtration becomes insufficient by clogging of the filter device and the internal pressure increased abruptly in the container, the pressure-difference detector can detect it, and the damper is operated by a pressure regulator and the comparator so as to control the air flow to the container. Thus, the internal pressure variation is controlled so as to easily ventilate the container. (J.P.N.)

  12. Instrument evaluation no. 13. Nuclear enterprises portable meter type PDR

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the evaluation of Nuclear Enterprises Portable Dose Rate Meter Type PDR 2

  13. Predictors of Instrumental Music Teacher Job Satisfaction

    Science.gov (United States)

    Bryant, Robert Louis, III

    2012-01-01

    Previous research studies related to teacher quality have found that teacher attrition rates are at an all-time high. Although much research has been conducted in the area of job satisfaction within the general teaching population, few studies of job satisfaction exist for instrumental music teachers. The purpose of this correlational study was to…

  14. Advanced Instrumentation for Positron Emission Tomography [PET

    Science.gov (United States)

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  15. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  16. Radiation Budget Instrument (RBI) for JPSS-2

    Science.gov (United States)

    Georgieva, Elena; Priestley, Kory; Dunn, Barry; Cageao, Richard; Barki, Anum; Osmundsen, Jim; Turczynski, Craig; Abedin, Nurul

    2015-01-01

    Radiation Budget Instrument (RBI) will be one of five instruments flying aboard the JPSS-2 spacecraft, a polar-orbiting sun-synchronous satellite in Low Earth Orbit. RBI is a passive remote sensing instrument that will follow the successful legacy of the Clouds and Earth's Radiant Energy System (CERES) instruments to make measurement of Earth's short and longwave radiation budget. The goal of RBI is to provide an independent measurement of the broadband reflected solar radiance and Earth's emitted thermal radiance by using three spectral bands (Shortwave, Longwave, and Total) that will have the same overlapped point spread function (PSF) footprint on Earth. To ensure precise NIST-traceable calibration in space the RBI sensor is designed to use a visible calibration target (VCT), a solar calibration target (SCT), and an infrared calibration target (ICT) containing phase change cells (PCC) to enable on-board temperature calibration. The VCT is a thermally controlled integrating sphere with space grade Spectralon covering the inner surface. Two sides of the sphere will have fiber-coupled laser diodes in the UV to IR wavelength region. An electrical substitution radiometer on the integrating sphere will monitor the long term stability of the sources and the possible degradation of the Spectralon in space. In addition the radiometric calibration operations will use the Spectralon diffusers of the SCT to provide accurate measurements of Solar degradation. All those stable on-orbit references will ensure that calibration stability is maintained over the RBI sensor lifetime. For the preflight calibration the RBI will view five calibration sources - two integrating spheres and three CrIS (Cross-track Infrared Sounder ) -like blackbodies whose outputs will be validated with NIST calibration approach. Thermopile are the selected detectors for the RBI. The sensor has a requirement to perform lunar calibration in addition to solar calibration in space in a way similar to CERES

  17. Roger Long’s gut-strung keyboard instruments and Thomas Barton’s harpsichord stringing

    OpenAIRE

    Rowland, David

    2016-01-01

    In 1720 Pepusch signed an inventory of the Duke of Chandos’s instruments that included a gut-strung harpsichord by a ‘Mr Longfellow of Pembroke Hall in Cambridge’. The maker was in fact Roger Long, Fellow and later Master of Pembroke Hall (now Pembroke College), Lowndes Professor of Astronomy, but also a keen musician and maker of astronomical, musical and other instruments. Long’s commonplace book in Pembroke’s library contains valuable information about gut and wire harpsichord stringing fr...

  18. A SHARIA RETURN AS AN ALTERNATIVE INSTRUMENT FOR MONETARY POLICY

    Directory of Open Access Journals (Sweden)

    Ashief Hamam

    2011-09-01

    Full Text Available Rapid development in Islamic financial industry has not been supported by sharia monetary policy instruments. This study looks at the possibility of sharia returns as the instrument. Using both error correction model and vector error correction model to estimate the data from 2002(1 to 2010(12, this paper finds that sharia return has the same effect as the interest rate in the demand for money. The shock effect of sharia return on broad money supply, Gross Domestic Product, and Consumer Price Index is greater than that of interest rate. In addition, these three variables are more quickly become stable following the shock of sharia return. Keywords: Sharia return, islamic financial system, vector error correction modelJEL classification numbers: E52, G15

  19. Two new portable survey instruments: the field phoswich detector and the Wee Pee Pee

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1978-01-01

    As part of a continuing program to upgrade the health physics survey instrumentation at Los Alamos, we have recently developed two new portable instruments. The first is a fully portable phoswich detector for low energy photons from small amounts of plutonium and americium in the field. The instrument has a background that is 2 to 3 times lower than an equivalent thin NaI detector. The instrument features an aural popper, analogue rate meter, and timer/scaler with liquid crystal display. The second instrument, called the ''Wee Pee Wee,'' is an alpha air proportional probe with complete electronics and readout package mounted on the probe itself. The entire package has a mass of 0.66 kg (1.45 lb) and is carried and operated in one hand. For monitoring shoes and other places where it is difficult to read the count-rate meter, the meter is made detachable for clipping to a shirt pocket, etc. An audio popper, range scales to 100 K cpm, and visual checks for high voltage and battery levels are also included

  20. The development and validation of the speech quality instrument.

    Science.gov (United States)

    Chen, Stephanie Y; Griffin, Brianna M; Mancuso, Dean; Shiau, Stephanie; DiMattia, Michelle; Cellum, Ilana; Harvey Boyd, Kelly; Prevoteau, Charlotte; Kohlberg, Gavriel D; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-12-08

    Although speech perception tests are available to evaluate hearing, there is no standardized validated tool to quantify speech quality. The objective of this study is to develop a validated tool to measure quality of speech heard. Prospective instrument validation study of 35 normal hearing adults recruited at a tertiary referral center. Participants listened to 44 speech clips of male/female voices reciting the Rainbow Passage. Speech clips included original and manipulated excerpts capturing goal qualities such as mechanical and garbled. Listeners rated clips on a 10-point visual analog scale (VAS) of 18 characteristics (e.g. cartoonish, garbled). Skewed distribution analysis identified mean ratings in the upper and lower 2-point limits of the VAS (ratings of 8-10, 0-2, respectively); items with inconsistent responses were eliminated. The test was pruned to a final instrument of nine speech clips that clearly define qualities of interest: speech-like, male/female, cartoonish, echo-y, garbled, tinny, mechanical, rough, breathy, soothing, hoarse, like, pleasant, natural. Mean ratings were highest for original female clips (8.8) and lowest for not-speech manipulation (2.1). Factor analysis identified two subsets of characteristics: internal consistency demonstrated Cronbach's alpha of 0.95 and 0.82 per subset. Test-retest reliability of total scores was high, with an intraclass correlation coefficient of 0.76. The Speech Quality Instrument (SQI) is a concise, valid tool for assessing speech quality as an indicator for hearing performance. SQI may be a valuable outcome measure for cochlear implant recipients who, despite achieving excellent speech perception, often experience poor speech quality. 2b. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  1. SEM analysis of defects and wear on Ni-Ti rotary instruments.

    Science.gov (United States)

    Arantes, Werington Borges; da Silva, Celso Monteiro; Lage-Marques, José Luiz; Habitante, Sandramarcia; da Rosa, Luiz Carlos Laureano; de Medeiros, João Marcelo Ferreira

    2014-01-01

    SEM analysis of endodontic instruments from a Ni-Ti rotary system was assessed, before and after using them, considering their defects and deformations. Twenty Twisted File®, BioRąCe®, Mtwo®, and EndoWave® instruments were micrographed at 190× magnification. The files were washed and micrographed again to view alterations as to the presence or absence of irregular edges, grooves, microcavities, and scraping. Simulated root canal preparations were performed using these instruments. The instruments were cleaned and received a microscopic analysis after being used five times. After analysis tests were tested using Fisher's exact test and Kappa to evaluate the concordance among examiners. There was a statistically significant difference with respect to deformations between Twisted File® and other instruments (p  0.05). All Twisted File® instruments showed the same defects; however damage were lower than those found in BioRace® and Mtwo®. The Endowave® did not show the same defects. In accordance with the data we conclude that the presence of defects was higher in Twisted File® instruments as the instruments and BioRace® Mtwo® brand, the defect rate was smaller and Endowave® instruments had no defects. Regarding the presence of wear after five uses among the groups all instruments showed changes in their cutting blades. © 2014 Wiley Periodicals, Inc.

  2. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  3. Examination of a clinical teaching effectiveness instrument used for summative faculty assessment.

    Science.gov (United States)

    Bierer, S Beth; Hull, Alan L

    2007-12-01

    This study explores whether a clinical teaching effectiveness (CTE) instrument provides valid scores for summative faculty assessment. The sample included all CTE instruments (n = 10,087) that learners (N = 1,194) completed to assess clinical teachers (N = 872) during 1 academic year. The authors investigated response processes (e.g., missing data, straight-line responses, level of learner), internal structure (e.g., confirmatory and exploratory factor analysis), teaching ratings by learner group (medical student or resident), and relation to other variables (e.g., correlation with global rating). Response processes identified a high prevalence of straight-line responses (same rating across all items) and differential patterns of missing data by learner group. Medical students rated their teachers higher than residents, and CTE scores had different factor structures depending on learner group. High correlation coefficients of CTE items with a single rating of overall teaching performance suggest that learners consider global performance when assessing clinical teaching performance.

  4. Rapid Measurement of Neutron Dose Rate for Transport Index

    International Nuclear Information System (INIS)

    Morris, R.L.

    2000-01-01

    A newly available neutron dose equivalent remmeter with improved sensitivity and energy response has been put into service at Rocky Flats Environmental Technology Site (RFETS). This instrument is being used to expedite measurement of the Transport Index and as an ALARA tool to identify locations where slightly elevated neutron dose equivalent rates exist. The meter is capable of measuring dose rates as low as 0.2 μSv per hour (20 μrem per hour). Tests of the angular response and energy response of the instrument are reported. Calculations of the theoretical instrument response made using MCNPtrademark are reported for materials typical of those being shipped

  5. Instrumentation for Kinetic-Inductance-Detector-Based Submillimeter Radio Astronomy

    Science.gov (United States)

    Duan, Ran

    A substantial amount of important scientific information is contained within astronomical data at the submillimeter and far-infrared (FIR) wavelengths, including information regarding dusty galaxies, galaxy clusters, and star-forming regions; however, these wavelengths are among the least-explored fields in astronomy because of the technological difficulties involved in such research. Over the past 20 years, considerable efforts have been devoted to developing submillimeter- and millimeter-wavelength astronomical instruments and telescopes. The number of detectors is an important property of such instruments and is the subject of the current study. Future telescopes will require as many as hundreds of thousands of detectors to meet the necessary requirements in terms of the field of view, scan speed, and resolution. A large pixel count is one benefit of the development of multiplexable detectors that use kinetic inductance detector (KID) technology. This dissertation presents the development of a KID-based instrument including a portion of the millimeter-wave bandpass filters and all aspects of the readout electronics, which together enabled one of the largest detector counts achieved to date in submillimeter-/millimeter-wavelength imaging arrays: a total of 2304 detectors. The work presented in this dissertation has been implemented in the MUltiwavelength Submillimeter Inductance Camera (MUSIC), a new instrument for the Caltech Submillimeter Observatory (CSO).

  6. Information needs and instrumentation for hydrogen control and management

    Energy Technology Data Exchange (ETDEWEB)

    Park, Gun Chul; Suh, Kune Y.; Lee, Seung Dong; Lee, Jin Yong [Seoul National Univ., Seoul (Korea, Republic of); Jae, Moo Sung [Hanyang Univ., Seoul (Korea, Republic of)

    2000-03-15

    In this study we examined instrument information, which is related to the severe accident management, guidance. We also examined the hydrogen control and management strategy. Hydrogen control occupies and important part in severe accident management and adequate hydrogen control strategy i needed to maintain the plant integrity. Reducing containment hydrogen during a severe accident will mitigate a potential containment failure mechanism. One of the hydrogen control strategies os intentional burning by the hydrogen igniter. Though intentional hydrogen burn strategy may cause pressure and temperature spikes, which are adverse effects, it si the fastest way of reducing the containment hydrogen concentration. From the Ulchin 3 and 4 plant information we developed a simple hydrogen ignition decision tree. And from the information of decision tree, hydrogen ignition decision can be determined in Containment Event Tree (CET). The end branch values in the CET are hydrogen concentrations, which will be used to assess the accident management measure.

  7. Information needs and instrumentation for hydrogen control and management

    International Nuclear Information System (INIS)

    Park, Gun Chul; Suh, Kune Y.; Lee, Seung Dong; Lee, Jin Yong; Jae, Moo Sung

    2000-03-01

    In this study we examined instrument information, which is related to the severe accident management, guidance. We also examined the hydrogen control and management strategy. Hydrogen control occupies and important part in severe accident management and adequate hydrogen control strategy i needed to maintain the plant integrity. Reducing containment hydrogen during a severe accident will mitigate a potential containment failure mechanism. One of the hydrogen control strategies os intentional burning by the hydrogen igniter. Though intentional hydrogen burn strategy may cause pressure and temperature spikes, which are adverse effects, it si the fastest way of reducing the containment hydrogen concentration. From the Ulchin 3 and 4 plant information we developed a simple hydrogen ignition decision tree. And from the information of decision tree, hydrogen ignition decision can be determined in Containment Event Tree (CET). The end branch values in the CET are hydrogen concentrations, which will be used to assess the accident management measure

  8. Surveillance of sealed containers with plutonium oxide materials (ms163)

    Science.gov (United States)

    Worl, Laura; Berg, John; Ford, Doris; Martinez, Max; McFarlan, Jim; Morris, John; Padilla, Dennis; Rau, Karen; Smith, Coleman; Veirs, Kirk; Hill, Dallas; Prenger, Coyne

    2000-07-01

    DOE is embarking upon a program to store large quantities of plutonium-bearing materials for up to fifty years. Materials destined for long-term storage include metals and oxides that are stabilized and packaged according to the DOE storage standard, where the packaging consists of two nested, welded, stainless steel containers. We have designed instrumented storage containers that mimic the inner storage can specified in the 3013 standard at both full- and small-scale capacities (2.4 liter and 0.005 liter, respectively), Figures 1 and 2. The containers are designed to maintain the volume to material mass ratio while allowing the gas composition and pressure to be monitored over time.

  9. Information needs and instrumentation availability for hydrogen control and management

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hong [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Park, Gun Chul; Suh, Kune Y.; Lee, Seung Dong; Lee, Jin Yong [Seoul National Univ., Seoul (Korea, Republic of); Jae, Moo Sung [Hansung Univ., Seoul (Korea, Republic of)

    1999-03-15

    This study is concerned with development of comprehensive hydrogen management strategies based on identification of a severe accident condition and formulation of hydrogen models. Reducing containment hydrogen during a severe accident will mitigate a potential containment failure mechanism. One of the hydrogen control strategies is intentional burning by the hydrogen igniter. Though intentional hydrogen burn strategy will cause pressure and temperature spikes, it is the fastest way of reducing the containment hydrogen concentration. Based on the Westinghouse owners group Severe Accident Management Guidance (SAMG) hydrogen ignition decision tree was developed. From the information of decision tree, hydrogen ignition decision can be determined in Containment Event Tree (CET). We have examined previous hydrogen generation related models in fuel coolant interaction (FCI) and developed transient model for it. Using this model, we have simulated the Argonne National Laboratory (ANL) tests which are single droplet experiments, and Fully Instrumented Test Site (FITS) tests which contain dynamic fragmentation.

  10. Proof testing of an explosion containment vessel

    Energy Technology Data Exchange (ETDEWEB)

    Esparza, E.D. [Esparza (Edward D.), San Antonio, TX (United States); Stacy, H.; Wackerle, J. [Los Alamos National Lab., NM (United States)

    1996-10-01

    A steel containment vessel was fabricated and proof tested for use by the Los Alamos National Laboratory at their M-9 facility. The HY-100 steel vessel was designed to provide total containment for high explosives tests up to 22 lb (10 kg) of TNT equivalent. The vessel was fabricated from an 11.5-ft diameter cylindrical shell, 1.5 in thick, and 2:1 elliptical ends, 2 in thick. Prior to delivery and acceptance, three types of tests were required for proof testing the vessel: a hydrostatic pressure test, air leak tests, and two full design charge explosion tests. The hydrostatic pressure test provided an initial static check on the capacity of the vessel and functioning of the strain instrumentation. The pneumatic air leak tests were performed before, in between, and after the explosion tests. After three smaller preliminary charge tests, the full design charge weight explosion tests demonstrated that no yielding occurred in the vessel at its rated capacity. The blast pressures generated by the explosions and the dynamic response of the vessel were measured and recorded with 33 strain channels, 4 blast pressure channels, 2 gas pressure channels, and 3 displacement channels. This paper presents an overview of the test program, a short summary of the methodology used to predict the design blast loads, a brief description of the transducer locations and measurement systems, some of the hydrostatic test strain and stress results, examples of the explosion pressure and dynamic strain data, and some comparisons of the measured data with the design loads and stresses on the vessel.

  11. Risk factors for cesarean section and instrumental vaginal delivery after successful external cephalic version.

    Science.gov (United States)

    de Hundt, Marcella; Vlemmix, Floortje; Bais, Joke M J; de Groot, Christianne J; Mol, Ben Willem; Kok, Marjolein

    2016-01-01

    Aim of this article is to examine if we could identify factors that predict cesarean section and instrumental vaginal delivery in women who had a successful external cephalic version. We used data from a previous randomized trial among 25 hospitals and their referring midwife practices in the Netherlands. With the data of this trial, we performed a cohort study among women attempting vaginal delivery after successful ECV. We evaluated whether maternal age, gestational age, parity, time interval between ECV and delivery, birth weight, neonatal gender, and induction of labor were predictive for a vaginal delivery on one hand or a CS or instrumental vaginal delivery on the other hand. Unadjusted and adjusted odds ratios were calculated with univariate and multivariate logistic regression analysis. Among 301 women who attempted vaginal delivery after a successful external cephalic version attempt, the cesarean section rate was 13% and the instrumental vaginal delivery rate 6%, resulting in a combined instrumental delivery rate of 19%. Nulliparity increased the risk of cesarean section (OR 2.7 (95% CI 1.2-6.1)) and instrumental delivery (OR 4.2 (95% CI 2.1-8.6)). Maternal age, gestational age at delivery, time interval between external cephalic version and delivery, birth weight and neonatal gender did not contribute to the prediction of failed spontaneous vaginal delivery. In our cohort of 301 women with a successful external cephalic version, nulliparity was the only one of seven factors that predicted the risk for cesarean section and instrumental vaginal delivery.

  12. Developing a Teacher Evaluation Instrument to Provide Formative Feedback Using Student Ratings of Teaching Acts

    Science.gov (United States)

    van der Lans, Rikkert M.; van de Grift, Wim J. C. M.; van Veen, Klaas

    2015-01-01

    This study reports on the development of a teacher evaluation instrument, based on students' observations, which exhibits cumulative ordering in terms of the complexity of teaching acts. The study integrates theory on teacher development with theory on teacher effectiveness and applies a cross-validation procedure to verify whether teaching acts…

  13. Highly Reliable Power and Communication System for Essential Instruments under a Severe Accident of NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, S. J.; Choi, B. H.; Jung, S. Y.; Rim, Chun T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    failure. Firstly, the life time of emergency batteries after the station blackout (SBO) was insufficient to operate targeted instruments. Secondly, the absence of proper protection in the containment building for extremely harsh environment after severe accident caused malfunctions. Lastly, since the power or communication cable was cut off, the instruments in the containment building could not transmit information to the outside, or their power source could be lost because most of the equipment in NPPs is wired-system based.

  14. Highly Reliable Power and Communication System for Essential Instruments under a Severe Accident of NPPs

    International Nuclear Information System (INIS)

    Yoo, S. J.; Choi, B. H.; Jung, S. Y.; Rim, Chun T.

    2013-01-01

    failure. Firstly, the life time of emergency batteries after the station blackout (SBO) was insufficient to operate targeted instruments. Secondly, the absence of proper protection in the containment building for extremely harsh environment after severe accident caused malfunctions. Lastly, since the power or communication cable was cut off, the instruments in the containment building could not transmit information to the outside, or their power source could be lost because most of the equipment in NPPs is wired-system based

  15. Peak capacity, peak-capacity production rate, and boiling point resolution for temperature-programmed GC with very high programming rates

    Science.gov (United States)

    Grall; Leonard; Sacks

    2000-02-01

    Recent advances in column heating technology have made possible very fast linear temperature programming for high-speed gas chromatography. A fused-silica capillary column is contained in a tubular metal jacket, which is resistively heated by a precision power supply. With very rapid column heating, the rate of peak-capacity production is significantly enhanced, but the total peak capacity and the boiling-point resolution (minimum boiling-point difference required for the separation of two nonpolar compounds on a nonpolar column) are reduced relative to more conventional heating rates used with convection-oven instruments. As temperature-programming rates increase, elution temperatures also increase with the result that retention may become insignificant prior to elution. This results in inefficient utilization of the down-stream end of the column and causes a loss in the rate of peak-capacity production. The rate of peak-capacity production is increased by the use of shorter columns and higher carrier gas velocities. With high programming rates (100-600 degrees C/min), column lengths of 6-12 m and average linear carrier gas velocities in the 100-150 cm/s range are satisfactory. In this study, the rate of peak-capacity production, the total peak capacity, and the boiling point resolution are determined for C10-C28 n-alkanes using 6-18 m long columns, 50-200 cm/s average carrier gas velocities, and 60-600 degrees C/min programming rates. It was found that with a 6-meter-long, 0.25-mm i.d. column programmed at a rate of 600 degrees C/min, a maximum peak-capacity production rate of 6.1 peaks/s was obtained. A total peak capacity of about 75 peaks was produced in a 37-s long separation spanning a boiling-point range from n-C10 (174 degrees C) to n-C28 (432 degrees C).

  16. Containment loads due to direct containment heating and associated hydrogen behavior: Analysis and calculations with the CONTAIN code

    International Nuclear Information System (INIS)

    Williams, D.C.; Bergeron, K.D.; Carroll, D.E.; Gasser, R.D.; Tills, J.L.; Washington, K.E.

    1987-05-01

    One of the most important unresolved issues governing risk in many nuclear power plants involves the phenomenon called direct containment heating (DCH), in which it is postulated that molten corium ejected under high pressure from the reactor vessel is dispersed into the containment atmosphere, thereby causing sufficient heating and pressurization to threaten containment integrity. Models for the calculation of potential DCH loads have been developed and incorporated into the CONTAIN code for severe accident analysis. Using CONTAIN, DCH scenarios in PWR plants having three different representative containment types have been analyzed: Surry (subatmospheric large dry containment), Sequoyah (ice condenser containment), and Bellefonte (atmospheric large dry containment). A large number of parameter variation and phenomenological uncertainty studies were performed. Response of DCH loads to these variations was found to be quite complex; often the results differ substantially from what has been previously assumed concerning DCH. Containment compartmentalization offers the potential of greatly mitigating DCH loads relative to what might be calculated using single-cell representations of containments, but the actual degree of mitigation to be expected is sensitive to many uncertainties. Dominant uncertainties include hydrogen combustion phenomena in the extreme environments produced by DCH scenarios, and factors which affect the rate of transport of DCH energy to the upper containment. In addition, DCH loads can be aggravated by rapid blowdown of the primary system, co-dispersal of moderate quantities of water with the debris, and quenching of de-entrained debris in water; these factors act by increasing steam flows which, in turn, accelerates energy transport. It may be noted that containment-threatening loads were calculated for a substantial portion of the scenarios treated for some of the plants considered

  17. Identifying instruments to quantify financial management skills in adults with acquired cognitive impairments.

    Science.gov (United States)

    Engel, Lisa; Bar, Yael; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R

    2016-01-01

    Financial management skills-that is, the skills needed to handle personal finances such as banking and paying bills-are essential to a person's autonomy, independence, and community living. To date, no comprehensive review of financial management skills instruments exists, making it difficult for clinicians and researchers to choose relevant instruments. The objectives of this review are to: (a) identify all available instruments containing financial management skill items that have been used with adults with acquired cognitive impairments; (b) categorize the instruments by source (i.e., observation based, self-report, proxy report); and (c) describe observation-based performance instruments by populations, overarching concepts measured, and comprehensiveness of financial management items. Objective (c) focuses on observation-based performance instruments as these measures can aid in situations where the person with cognitive impairment has poor self-awareness or where the proxy has poor knowledge of the person's current abilities. Two reviewers completed two systematic searches of five databases. Instruments were categorized by reviewing published literature, copies of the instruments, and/or communication with instrument authors. Comprehensiveness of items was based on nine key domains of financial management skills developed by the authors. A total of 88 discrete instruments were identified. Of these, 44 were categorized as observation-based performance and 44 as self- and/or proxy-reports. Of the 44 observation-based performance instruments, 8 had been developed for acquired brain injury populations and 24 for aging and dementia populations. Only 7 of the observation-based performance instruments had items spanning 6 or more of the 9 financial management skills domains. The majority of instruments were developed for aging and dementia populations, and few were comprehensive. This review provides foundation for future instrument psychometric and clinimetric

  18. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  19. Assessment of the wish to hasten death in patients with advanced disease: A systematic review of measurement instruments.

    Science.gov (United States)

    Bellido-Pérez, Mercedes; Monforte-Royo, Cristina; Tomás-Sábado, Joaquín; Porta-Sales, Josep; Balaguer, Albert

    2017-06-01

    Patients with advanced conditions may present a wish to hasten death. Assessing this wish is complex due to the nature of the phenomenon and the difficulty of conceptualising it. To identify and analyse existing instruments for assessing the wish to hasten death and to rate their reported psychometric properties. Systematic review based on PRISMA guidelines. The COnsensus-based Standards for the selection of health Measurement INstruments checklist was used to evaluate the methodological quality of validation studies and the measurement properties of the instrument described. The CINAHL, PsycINFO, Pubmed and Web of Science databases were searched from inception to November 2015. A total of 50 articles involving assessment of the wish to hasten death were included. Eight concerned instrument validation and were evaluated using COnsensus-based Standards for the selection of health Measurement INstruments criteria. They reported data for between two and seven measurement properties, with ratings between fair and excellent. Of the seven instruments identified, the Desire for Death Rating Scale or the Schedule of Attitudes toward Hastened Death feature in 48 of the 50 articles. The Schedule of Attitudes toward Hastened Death is the most widely used and is the instrument whose psychometric properties have been most often analysed. Versions of the Schedule of Attitudes toward Hastened Death are available in five languages other than the original English. This systematic review has analysed existing instruments for assessing the wish to hasten death. It has also explored the methodological quality of studies that have examined the measurement properties of these instruments and offers ratings of the reported properties. These results will be useful to clinicians and researchers with an interest in a phenomenon of considerable relevance to advanced patients.

  20. Two-port laparoscopic ovarian cystectomy using 3-mm instruments

    Directory of Open Access Journals (Sweden)

    Naoyuki Yoshiki

    2016-05-01

    Conclusion: Two-port laparoscopic ovarian cystectomy using 3-mm instruments is a feasible and safe approach by which surgeons expert in conventional multiport laparoscopy achieve minimally invasive surgery with low morbidity and a low rate of conversion to the conventional approach.

  1. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  2. Instrumentation and Controls Division progress report, July 1, 1990--June 30, 1992. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    This report contains the following information from the Instrumentation and Controls Division of Oak Ridge National Laboratory: supplementary activities; seminars; publications and presentations; scientific and professional activities, achievements, and awards; and division organization charts.

  3. Influence of temperature on strain monitoring of degradation in concrete containment buildings

    International Nuclear Information System (INIS)

    Ding, Y.; Jaffer, S.; Angell, P.

    2015-01-01

    Concrete containment buildings (CCBs) are important safety structures in a nuclear power plant (NPP). The CCBs can be made of reinforced and post-tensioned (P-T) concrete. Post-tensioning concrete induces compressive stresses, which have to be overcome for the concrete to crack under tensile loads. However, post-tensioned CCBs may undergo pre-stressing losses as they age, which could affect their performance under accident conditions. CANDU 6 reactor buildings contain grouted post-tensioned tendons as the primary reinforcement. The grouting of the tendons makes direct monitoring of pre-stressing losses via lift-off testing impossible. Therefore, instruments have been installed on an existing reactor building to measure and monitor strains and stresses in the concrete and the deformation of the concrete structure to detect aging degradation and indirectly evaluate the pre-stressing losses. However, the instrumentation readings are affected by temporary volume changes in the concrete caused by the influence of environmental factors, particularly temperature, on concrete. In this work, the focus is on developing an understanding of the effect of temperature on the interpretation of instrumentation data from a reactor building. Vibrating Wire Strain Gauge (VWSG) data has been analysed. The influence of concrete coefficient of thermal expansion and temperature distribution within the reactor building walls, on VWSG data, is discussed based on the analysis of the available instrumentation data and available numerical simulation results. The present study demonstrates that temperature distribution within the containment concrete has a significant impact on the VWSG measurements and the coefficient of thermal expansion of concrete is an important factor in the correction of VWSG data for thermal strain. It is recommended that VWSG data obtained over small temperature variations be considered for interpretation to assess pre-stressing losses. (authors)

  4. ICFA instrumentation bulletin, Volume 15, Fall 1997 issue

    International Nuclear Information System (INIS)

    Va'vra, J.

    1997-12-01

    The Bulletin reports on research and progress in the field of instrumentation with emphasis in the field of high-energy physics. This volume contains the following four papers: (1) Streamers in MSGC's and Other Gaseous Detectors; (2) Soft X-Ray Production in Spark Discharges in Hydrogen, Nitrogen, Air, Argon, and Xenon Gases; (3) Beam Tests of the CLEO III LiF-TEA Ring Imaging Cherenkov Detector; and (4) Electron Multiplication and Secondary Scintillation in Liquid Xenon: New Prospects

  5. Development and validation of an instrument to assess job satisfaction in eye-care personnel.

    Science.gov (United States)

    Paudel, Prakash; Cronjé, Sonja; O'Connor, Patricia M; Khadka, Jyoti; Rao, Gullapalli N; Holden, Brien A

    2017-11-01

    The aim was to develop and validate an instrument to measure job satisfaction in eye-care personnel and assess the job satisfaction of one-year trained vision technicians in India. A pilot instrument for assessing job satisfaction was developed, based on a literature review and input from a public health expert panel. Rasch analysis was used to assess psychometric properties and to undertake an iterative item reduction. The instrument was then administered to vision technicians in vision centres of Andhra Pradesh in India. Associations between vision technicians' job satisfaction and factors such as age, gender and experience were analysed using t-test and one-way analysis of variance. Rasch analysis confirmed that the 15-item job satisfaction in eye-care personnel (JSEP) was a unidimensional instrument with good fit statistics, measurement precisions and absence of differential item functioning. Overall, vision technicians reported high rates of job satisfaction (0.46 logits). Age, gender and experience were not associated with high job satisfaction score. Item score analysis showed non-financial incentives, salary and workload were the most important determinants of job satisfaction. The 15-item JSEP instrument is a valid instrument for assessing job satisfaction among eye-care personnel. Overall, vision technicians in India demonstrated high rates of job satisfaction. © 2016 Optometry Australia.

  6. Bioimpedance-Based Wearable Measurement Instrumentation for Studying the Autonomic Nerve System Response to Stressful Working Conditions

    Science.gov (United States)

    Ferreira, J.; Álvarez, L.; Buendía, R.; Ayllón, D.; Llerena, C.; Gil-Pita, R.; Seoane, F.

    2013-04-01

    The assessment of mental stress on workers under hard and stressful conditions is critical to identify which workers are not ready to undertake a mission that might put in risk their own life and the life of others. The ATREC project aims to enable Real Time Assessment of Mental Stress of the Spanish Armed Forces during military activities. Integrating sensors with garments and using wearable measurement devices, the following physiological measurements were recorded: heart and respiration rate, skin galvanic response as well as peripheral temperature. The measuring garments are the following: a sensorized glove, an upper-arm strap and a repositionable textrode chest strap system with 6 textrodes. The implemented textile-enabled instrumentation contains: one skin galvanometer, two temperature sensors, for skin and environmental, and an Impedance Cardiographer/Pneumographer containing a 1 channel ECG amplifier to record cardiogenic biopotentials. The implemented wearable systems operated accordingly to the specifications and are ready to be used for the mental stress experiments that will be executed in the coming phases of the project in healthy volunteers.

  7. Bioimpedance-Based Wearable Measurement Instrumentation for Studying the Autonomic Nerve System Response to Stressful Working Conditions

    International Nuclear Information System (INIS)

    Ferreira, J; Buendía, R; Seoane, F; Álvarez, L; Ayllón, D; Llerena, C; Gil-Pita, R

    2013-01-01

    The assessment of mental stress on workers under hard and stressful conditions is critical to identify which workers are not ready to undertake a mission that might put in risk their own life and the life of others. The ATREC project aims to enable Real Time Assessment of Mental Stress of the Spanish Armed Forces during military activities. Integrating sensors with garments and using wearable measurement devices, the following physiological measurements were recorded: heart and respiration rate, skin galvanic response as well as peripheral temperature. The measuring garments are the following: a sensorized glove, an upper-arm strap and a repositionable textrode chest strap system with 6 textrodes. The implemented textile-enabled instrumentation contains: one skin galvanometer, two temperature sensors, for skin and environmental, and an Impedance Cardiographer/Pneumographer containing a 1 channel ECG amplifier to record cardiogenic biopotentials. The implemented wearable systems operated accordingly to the specifications and are ready to be used for the mental stress experiments that will be executed in the coming phases of the project in healthy volunteers.

  8. Safety Assessment of Two Hybrid Instrumentation Techniques in a Dental Student Endodontic Clinic: A Retrospective Study.

    Science.gov (United States)

    Coelho, Marcelo Santos; Card, Steven John; Tawil, Peter Zahi

    2017-03-01

    The aim of this study was to retrospectively assess the safety potential of a hybrid technique combining nickel-titanium (NiTi) reciprocating and rotary instruments by third- and fourth-year dental students in the predoctoral endodontics clinic at one U.S. dental school. For the study, 3,194 root canal treatments performed by 317 dental students from 2012 through 2015 were evaluated for incidence of ledge creation and instrument separation. The hybrid reciprocating and rotary technique (RRT) consisted of a glide path creation with stainless steel hand files up to size 15/02, a crown down preparation with a NiTi reciprocating instrument, and an apical preparation with NiTi rotary instruments. The control was a traditional rotary and hand technique (RHT) that consisted of the same glide path procedure followed by a crown down preparation with NiTi rotary instruments and an apical preparation with NiTi hand instruments. The results showed that the RHT technique presented a rate of ledge creation of 1.4% per root and the RRT technique was 0.5% per root (protary technique for root canal instrumentation by these dental students provided good safety. This hybrid technique offered a low rate of ledge creation along with no NiTi instrument separation.

  9. Design integration of favorable geometry, structural support and containment

    International Nuclear Information System (INIS)

    Purcell, J.A.; McGehee, G.A.

    1991-07-01

    In designs for fissile processes at Savannah River site, different approaches have been used to provide engineered margins of safety for criticality with containment and seismic resistance as additional requirements. These requirements are frequently at odds in engineered systems. This paper proposes a plan to take advantage of vessels with favorable geometry to provide seismic resistance and to support a glovebox for containment. Thin slab tanks, small diameter pencil tanks, annular tanks, and other novel designs have been used for criticality safety. The requirement for DBE seismic resistance and rigid control of dimensions leads the designer to consider annular tanks for meeting these requirements. The high strength of annular tanks may logically be used to support secondary containment. Hands-on access to all instruments, piping etc. within containment can be provided through gloveports, thus a specialized glovebox. This paper examines the advantages of using an annular tank design to provide favorable geometry, structural support and containment

  10. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  11. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  12. Usefulness of ACR MRI phantom for quality assurance of MRI instruments

    International Nuclear Information System (INIS)

    Lee, Jung Whee; Ahn, Kook Jin; Lee, Seung Koo; Na, Dong Gyu; Oh, Chang Hyun; Chang, Yong Min; Lim, Tae Hwan

    2006-01-01

    To examine whether the ACR phantom could be used in quality standards for magnetic resonance imaging (MRI) instruments in Korea. We conducted the phantom test using the ACR MRI phantom in 20 MRI instruments currently used in Korea. According to ACR criteria, we acquired the phantom images which were then assessed by the following seven tests: geometric accuracy, high spatial resolution, slice thickness accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting, and low contrast object detectability. The phantom images were interpreted by three experienced radiologists according to ACR criteria. Then, we examined the failure rate of each test and evaluated the inter-observer variation in the measurements and test failure. The failure rate of each test could be broken into the following components: geometric accuracy (11-21%), high contrast spatial resolution (10-15%), slice thickness accuracy(6-22%), slice position accuracy (5-17%), image intensity uniformity (6%), percent signal ghosting (16%), and low contrast object detectability (8-10%). In this series, all the failure rates were less than 30%. In addition, no inter-observer variation was seen in the measurements and test failure. ACR MRI phantom promises to be established as the standard phantom for MRI instruments in Korea because of its objectivity in assessing the phantom images

  13. Full blood count and haemozoin-containing leukocytes in children with malaria: diagnostic value and association with disease severity

    Directory of Open Access Journals (Sweden)

    Lell Bertrand

    2008-06-01

    Full Text Available Abstract Background Diligent and correct laboratory diagnosis and up-front identification of risk factors for progression to severe disease are the basis for optimal management of malaria. Methods Febrile children presenting to the Medical Research Unit at the Albert Schweitzer Hospital (HAS in Lambaréné, Gabon, were assessed for malaria. Giemsa-stained thick films for qualitative and quantitative diagnosis and enumeration of malaria pigment, or haemozoin (Hz-containing leukocytes (PCL were performed, and full blood counts (FBC were generated with a Cell Dyn 3000® instrument. Results Compared to standard light microscopy of Giemsa-stained thick films, diagnosis by platelet count only, by malaria pigment-containing monocytes (PCM only, or by pigment-containing granulocytes (PCN only yielded sensitivities/specificities of 92%/93%; 96%/96%; and 85%/96%, respectively. The platelet count was significantly lower in children with malaria compared to those without (p ® instrument detected significantly more patients with PCL (p Conclusion In the age group examined in the Lambaréné area, platelets are an excellent adjuvant tool to diagnose malaria. Pigment-containing leukocytes (PCL are more readily detected by automated scatter flow cytometry than by microscopy. Automated Hz detection by an instrument as used here is a reliable diagnostic tool and correlates with disease severity. However, clinical usefulness as a prognostic tool is limited due to an overlap of PCL numbers recorded in severe versus non-severe malaria. However, this is possibly because of the instrument detection algorithm was not geared towards this task, and data lost during processing; and thus adjusting the instrument's algorithm may allow to establish a meaningful cut-off value.

  14. Instruments for non-destructive evaluation of advanced test reactor inpile tubes

    International Nuclear Information System (INIS)

    Livingston, R.A.; Beller, L.S.; Edgett, S.M.

    1986-01-01

    The Advanced Test Reactor is a 250 MW LWR used primarily for irradiation testing of materials contained in inpile tubes that pass through the reactor core. These tubes provided the high pressure and temperature water environment required for the test specimens. The reactor cooling water surrounding the inpile tubes is at much lower pressure and temperature. The structural integrity of the inpile tubes is monitored by routine surveillance to ensure against unplanned reactor shutdowns to replace defective inpile tubes. The improved instruments developed for inpile tube surveillance include a bore profilometer, ultrasonic flaw detetion system and bore diameter gauges. The design and function of these improved instruments is presented

  15. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  16. IAEA eLearning Program: The Use of Radiation Detection Instruments

    International Nuclear Information System (INIS)

    2010-01-01

    This CD-ROM contains a computer based training on Radiation Detection Techniques for Nuclear Security Applications. The IAEA Nuclear Security eLearning tool offers computer based training to Frontline Officers to improve their understanding about key elements of the use of radiation detection instruments. The eLearning program prepares Frontline Officers for the IAEA Detection and Response Frontline Officer course

  17. Evaluation of physicians' professional performance: An iterative development and validation study of multisource feedback instruments

    Directory of Open Access Journals (Sweden)

    Overeem Karlijn

    2012-03-01

    Full Text Available Abstract Background There is a global need to assess physicians' professional performance in actual clinical practice. Valid and reliable instruments are necessary to support these efforts. This study focuses on the reliability and validity, the influences of some sociodemographic biasing factors, associations between self and other evaluations, and the number of evaluations needed for reliable assessment of a physician based on the three instruments used for the multisource assessment of physicians' professional performance in the Netherlands. Methods This observational validation study of three instruments underlying multisource feedback (MSF was set in 26 non-academic hospitals in the Netherlands. In total, 146 hospital-based physicians took part in the study. Each physician's professional performance was assessed by peers (physician colleagues, co-workers (including nurses, secretary assistants and other healthcare professionals and patients. Physicians also completed a self-evaluation. Ratings of 864 peers, 894 co-workers and 1960 patients on MSF were available. We used principal components analysis and methods of classical test theory to evaluate the factor structure, reliability and validity of instruments. We used Pearson's correlation coefficient and linear mixed models to address other objectives. Results The peer, co-worker and patient instruments respectively had six factors, three factors and one factor with high internal consistencies (Cronbach's alpha 0.95 - 0.96. It appeared that only 2 percent of variance in the mean ratings could be attributed to biasing factors. Self-ratings were not correlated with peer, co-worker or patient ratings. However, ratings of peers, co-workers and patients were correlated. Five peer evaluations, five co-worker evaluations and 11 patient evaluations are required to achieve reliable results (reliability coefficient ≥ 0.70. Conclusions The study demonstrated that the three MSF instruments produced

  18. Ergonomic investigation of weight distribution of laparoscopic instruments.

    Science.gov (United States)

    Lin, Chiuhsiang Joe; Chen, Hung-Jen; Lo, Ying-Chu

    2011-06-01

    Laparoscopic surgery procedures require highly specialized visually controlled movements. Investigations of industrial applications indicate that the length as well as the weight of hand-held tools substantially affects movement time (MT). Different weight distributions may have similar effects on long-shafted laparoscopic instruments when performing surgical procedures. For this reason, the current experiment aimed at finding direct evidence of the weight distribution effect in an accurate task. Ten right-handed subjects made continuous Fitts' pointing tasks using a long laparoscopic instrument. The factors and levels were target width: (2.5, 3, 3.5, and 4 cm), target distance (14, 23, and 37 cm), and weight distribution (uniform, front, middle, and rear). Weight distribution was made by chips of lead attached to the laparoscopic instrument. MT, error rate, and throughput (TP) were recorded as dependent variables. There were significant differences between the weight distribution in MT and in TP. The middle position was found to require the least time to manipulate the laparoscopic instrument in pointing tasks and also obtained the highest TP. These analyses and findings pointed to a design direction for the ergonomics and usability of the long hand-held tool such as the laparoscopic instrument in this study. To optimize efficiency in using these tools, the consideration of a better weight design is important and should not be neglected.

  19. A new device to test cutting efficiency of mechanical endodontic instruments

    Science.gov (United States)

    Rubini, Alessio Giansiracusa; Plotino, Gianluca; Al-Sudani, Dina; Grande, Nicola M.; Putorti, Ermanno; Sonnino, GianPaolo; Cotti, Elisabetta; Testarelli, Luca; Gambarini, Gianluca

    2014-01-01

    Background The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments. Material/Methods Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device developed to test the cutting ability of endodontic instruments. The device consists of a main frame to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1mm. The instruments were activated by using a torque-controlled motor (Silver Reciproc; VDW, Munich, Germany) in a reciprocating movement by the “Reciproc ALL” program (Group 1) and in counter-clockwise rotation at 300 rpm (Group 2). Mean and standard deviations of each group were calculated and data were statistically analyzed with a one-way ANOVA test (P0.05). Conclusions The cutting testing device evaluated in the present study was reliable and easy to use and may be effectively used to test cutting efficiency of both rotary and reciprocating mechanical endodontic instruments. PMID:24603777

  20. Tax system competition – instruments and beneficiaries

    OpenAIRE

    Krzysztof Biernacki

    2014-01-01

    Tax competition among states and jurisdictions has already been examined many times in the economic literature. However, the main scope of the research was focused on a tax rates competition in income taxes and its consequences in bringing direct investments. This scripture/commentary tries to analyze various instruments and beneficiaries of the tax system competition and provide a general overview on this subject.

  1. Technical evaluation of available state of Nevada survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada`s Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC`s work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public.

  2. Technical evaluation of available state of Nevada survey instruments

    International Nuclear Information System (INIS)

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada's Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC's work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public

  3. 26 CFR 1.1274-2 - Issue price of debt instruments to which section 1274 applies.

    Science.gov (United States)

    2010-04-01

    ... of the applicable qualified floating rate as of the date on which the sale or exchange occurs. (ii... ignored. (f) Treatment of variable rate debt instruments—(1) Stated interest at a qualified floating rate... qualified floating rate (or rates) is determined by assuming that the instrument provides for a fixed rate...

  4. Experimental results from pressure testing a 1:6-scale nuclear power plant containment

    International Nuclear Information System (INIS)

    Horschel, D.S.

    1992-01-01

    This report discusses the testing of a 1:6-scale, reinforced-concrete containment building at Sandia National Laboratories, in Albuquerque, New Mexico. The scale-model, Light Water Reactor (LWR) containment building was designed and built to the American Society of Mechanical Engineers (ASME) code by United Engineers and Constructors, Inc., and was instrumented with over 1200 transducers to prepare for the test. The containment model was tested to failure to determine its response to static internal overpressurization. As part of the US Nuclear Regulatory Commission's program on containment integrity, the test results will be used to assess the capability of analytical methods to predict the performance of containments under severe-accident loads. The scaled dimensions of the cylindrical wall and hemispherical dome were typical of a full-size containment. Other typical features included in the heavily reinforced model were equipment hatches, personnel air locks, several small piping penetrations, and a ihin steel liner that was attached to the concrete by headed studs. In addition to the transducers attached to the model, an acoustic detection system and several video and still cameras were used during testing to gather data and to aid in the conduct of the test. The model and its instrumentation are briefly discussed, and is followed by the testing procedures and measured response of the containment model. A summary discussion is included to aid in understanding the significance of the test as it applies to real world reinforced concrete containment structures. The data gathered during SIT and overpressure testing are included as an appendix

  5. Experimental results from pressure testing a 1:6-scale nuclear power plant containment

    Energy Technology Data Exchange (ETDEWEB)

    Horschel, D.S. [Sandia National Labs., Albuquerque, NM (United States)

    1992-01-01

    This report discusses the testing of a 1:6-scale, reinforced-concrete containment building at Sandia National Laboratories, in Albuquerque, New Mexico. The scale-model, Light Water Reactor (LWR) containment building was designed and built to the American Society of Mechanical Engineers (ASME) code by United Engineers and Constructors, Inc., and was instrumented with over 1200 transducers to prepare for the test. The containment model was tested to failure to determine its response to static internal overpressurization. As part of the US Nuclear Regulatory Commission`s program on containment integrity, the test results will be used to assess the capability of analytical methods to predict the performance of containments under severe-accident loads. The scaled dimensions of the cylindrical wall and hemispherical dome were typical of a full-size containment. Other typical features included in the heavily reinforced model were equipment hatches, personnel air locks, several small piping penetrations, and a ihin steel liner that was attached to the concrete by headed studs. In addition to the transducers attached to the model, an acoustic detection system and several video and still cameras were used during testing to gather data and to aid in the conduct of the test. The model and its instrumentation are briefly discussed, and is followed by the testing procedures and measured response of the containment model. A summary discussion is included to aid in understanding the significance of the test as it applies to real world reinforced concrete containment structures. The data gathered during SIT and overpressure testing are included as an appendix.

  6. Highly integrated Pluto payload system (HIPPS): a sciencecraft instrument for the Pluto mission

    Science.gov (United States)

    Stern, S. Alan; Slater, David C.; Gibson, William; Reitsema, Harold J.; Delamere, W. Alan; Jennings, Donald E.; Reuter, D. C.; Clarke, John T.; Porco, Carolyn C.; Shoemaker, Eugene M.; Spencer, John R.

    1995-09-01

    We describe the design concept for the highly integrated Pluto payload system (HIPPS): a highly integrated, low-cost, light-weight, low-power instrument payload designed to fly aboard the proposed NASA Pluto flyby spacecraft destined for the Pluto/Charon system. The HIPPS payload is designed to accomplish all of the Pluto flyby prime (IA) science objectives, except radio science, set forth by NASA's Outer Planets Science Working Group (OPSWG) and the Pluto Express Science Definition Team (SDT). HIPPS contains a complement of three instrument components within one common infrastructure; these are: (1) a visible/near UV CCD imaging camera; (2) an infrared spectrograph; and (3) an ultraviolet spectrograph. A detailed description of each instrument is presented along with how they will meet the IA science requirements.

  7. Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Slaughter, David M.; Stuart, Cory R.; Klaass, R. Fred; Merrill, David B. [MSI/Photogenics Division, Orem, Utah (United States)

    2015-07-01

    This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutrons that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing

  8. Effects of various freezing containers for vitrification freezing on mouse oogenesis.

    Science.gov (United States)

    Kim, Ji Chul; Kim, Jae Myeoung; Seo, Byoung Boo

    2016-01-01

    In the present study, various freezing containers were tested for mouse embryos of respective developmental stages; embryos were vitrified and then their survival rate and developmental rate were monitored. Mouse two cell, 8 cell, and blastula stage embryos underwent vitrification freezing-thawing and then their recovery rate, survival rate, development rate, and hatching rate were investigated. EM-grid, OPS, and cryo-loop were utilized for vitrification freezing-thawing of mouse embryos. It was found that recovery rate and survival rate were higher in the group of cryo-loop compared to those of EM-grid (p containers on vitrified embryos of respective developmental stages; it was demonstrated that higher developmental rate was shown in more progressed (or developed) embryos with more blastomeres. There was however, no difference in embryonic development rate was shown amongst containers. Taken together, further additional studies are warranted with regards to 1) manipulation techniques of embryos for various vitrification freezing containers and 2) preventive measures against contamination via liquid nitrogen.

  9. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  10. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  11. Self-rated and observer-rated measures of well-being and distress in adolescence: an exploratory study.

    Science.gov (United States)

    Vescovelli, Francesca; Albieri, Elisa; Ruini, Chiara

    2014-01-01

    The evaluation of eudaimonic well-being in adolescence is hampered by the lack of specific assessment tools. Moreover, with younger populations, the assessment of positive functioning may be biased by self-report data only, and may be more accurate by adding significant adults' evaluations. The objective of this research was to measure adolescents' well-being and prosocial behaviours using self-rated and observer-rated instruments, and their pattern of associations. The sample included 150 Italian high school adolescents. Observed-evaluation was performed by their school teachers using the Strengths and Difficulties Questionnaire. Adolescents completed Ryff's Psychological Well-being Scales and Symptom Questionnaire. Pearson' r correlations and Linear regression were performed. Self-rated dimensions of psychological well-being significantly correlated with all observer-rated dimensions, but Strengths and Difficulties Emotional symptom scale. Multiple linear regression showed that the self-rated dimensions Environmental Mastery and Personal Growth, and surprisingly not Positive Relations, are related to the observer-rated dimension Prosocial Behaviour. Adolescents with higher levels of well-being in specific dimensions tend to be perceived as less problematic by their teachers. However, some dimensions of positive functioning present discrepancies between self and observer-rated instruments. Thus, the conjunct use of self-reports and observer-rated tools for a more comprehensive assessment of students' eudaimonic well-being is recommended.

  12. Particulate metals and organic compounds from electronic and tobacco-containing cigarettes: comparison of emission rates and secondhand exposure.

    Science.gov (United States)

    Saffari, Arian; Daher, Nancy; Ruprecht, Ario; De Marco, Cinzia; Pozzi, Paolo; Boffi, Roberto; Hamad, Samera H; Shafer, Martin M; Schauer, James J; Westerdahl, Dane; Sioutas, Constantinos

    2014-01-01

    In recent years, electronic cigarettes have gained increasing popularity as alternatives to normal (tobacco-containing) cigarettes. In the present study, particles generated by e-cigarettes and normal cigarettes have been analyzed and the degree of exposure to different chemical agents and their emission rates were quantified. Despite the 10-fold decrease in the total exposure to particulate elements in e-cigarettes compared to normal cigarettes, specific metals (e.g. Ni and Ag) still displayed a higher emission rate from e-cigarettes. Further analysis indicated that the contribution of e-liquid to the emission of these metals is rather minimal, implying that they likely originate from other components of the e-cigarette device or other indoor sources. Organic species had lower emission rates during e-cigarette consumption compared to normal cigarettes. Of particular note was the non-detectable emission of polycyclic aromatic hydrocarbons (PAHs) from e-cigarettes, while substantial emission of these species was observed from normal cigarettes. Overall, with the exception of Ni, Zn, and Ag, the consumption of e-cigarettes resulted in a remarkable decrease in secondhand exposure to all metals and organic compounds. Implementing quality control protocols on the manufacture of e-cigarettes would further minimize the emission of metals from these devices and improve their safety and associated health effects.

  13. Assessing students' communication skills: validation of a global rating.

    Science.gov (United States)

    Scheffer, Simone; Muehlinghaus, Isabel; Froehmel, Annette; Ortwein, Heiderose

    2008-12-01

    Communication skills training is an accepted part of undergraduate medical programs nowadays. In addition to learning experiences its importance should be emphasised by performance-based assessment. As detailed checklists have been shown to be not well suited for the assessment of communication skills for different reasons, this study aimed to validate a global rating scale. A Canadian instrument was translated to German and adapted to assess students' communication skills during an end-of-semester-OSCE. Subjects were second and third year medical students at the reformed track of the Charité-Universitaetsmedizin Berlin. Different groups of raters were trained to assess students' communication skills using the global rating scale. Validity testing included concurrent validity and construct validity: Judgements of different groups of raters were compared to expert ratings as a defined gold standard. Furthermore, the amount of agreement between scores obtained with this global rating scale and a different instrument for assessing communication skills was determined. Results show that communication skills can be validly assessed by trained non-expert raters as well as standardised patients using this instrument.

  14. Evaluation of the FOCUS (Feedback on Counseling Using Simulation) instrument for assessment of client-centered nutrition counseling behaviors.

    Science.gov (United States)

    Henry, Beverly W; Smith, Thomas J

    2010-01-01

    To develop an instrument to assess client-centered counseling behaviors (skills) of student-counselors in a standardized patient (SP) exercise. Descriptive study of the accuracy and utility of a newly developed counseling evaluation instrument. Study participants included 11 female student-counselors at a Midwestern university-10 Caucasian, 1 African-American-for the simulated counseling sessions, in which the Feedback on Counseling Using Simulation (FOCUS) instrument was applied in 2 SP scenarios (cardiovascular disease and diabetes). FOCUS ratings of student-counselors by 4 SPs during 22 sessions were compared with ratings from a 3-member panel of experts who independently viewed the 22 videotaped sessions. Quantitative analysis of instrument validity included inter-rater reliability by computing generalizability coefficients, Pearson correlations, and Spearman rank-order correlations. FOCUS criteria encompassed relevant dimensions of nutrition counseling based in a client-centered perspective. The critical points of information gathering and counseling behaviors showed internal consistency overall and good inter-rater reliability with the cardiovascular disease scenario. For both scenarios, pooled ratings of 3 experts agreed with ratings carried out by SPs. Initial findings suggest that the FOCUS instrument with client-centered criteria may enhance evaluation of counseling skills in SP exercises, meriting further study with larger groups.

  15. A review of instruments developed to measure food neophobia

    DEFF Research Database (Denmark)

    Damsbo-Svendsen, Marie; Frøst, Michael Bom; Olsen, Annemarie

    2017-01-01

    Food choices are influenced by an individual's attitude towards foods. Food neophobia may be associated with less variety of diets, inadequate nutrient intake and high product failure rate for new food products entering the market. To quantify the extent of these challenges, instruments to measur...

  16. The Hinkley point 'B' instrumented stringer data logger

    International Nuclear Information System (INIS)

    Beynon, A.J.

    1975-10-01

    A computer based data logging system has been installed at Hinkley Point 'B'to accumulate and interpret data from instrumented stringers in Reactor 4. The logger has 90 thermocouple and 10 pressure transducer inputs, and is backed up by a manually operated system. Details of the logger and instructions in its use for anyone unfamiliar with it are given. Self-contained descriptions of each computer program, covering routine data acquisition and special purpose programs for measuring transient behaviour are then presented. (author)

  17. Can Two Psychotherapy Process Measures Be Dependably Rated Simultaneously? A Generalizability Study

    Science.gov (United States)

    Ulvenes, Pal G.; Berggraf, Lene; Hoffart, Asle; Levy, Raymon A.; Ablon, J. Stuart; McCullough, Leigh; Wampold, Bruce E.

    2012-01-01

    Observer ratings in psychotherapy are a common way of collecting information in psychotherapy research. However, human observers are imperfect instruments, and their ratings may be subject to variability from several sources. One source of variability can be raters' assessing more than 1 instrument at a time. The purpose of this research is to…

  18. Rapid heating tensile tests of high-energy-rate-forged 316L stainless steel containing internal helium from radioactive decay of absorbed tritium

    International Nuclear Information System (INIS)

    Mosley, W.C.

    1990-01-01

    316L stainless steel is a candidate material for construction of equipment that will be exposed to tritium. This austenitic stainless steel is frequently used in the high-energy-rate-forged (HERF) metallurgical condition to take advantage of increased strength produced by cold work introduced by this process. Proper design of tritium-handling equipment will require an understanding of how helium-3, the product of radioactive decay of tritium, affects mechanical properties. This report describes results of elevated-temperature tensile testing of HERF 316L stainless steel specimens containing helium concentrations of 171 (calculated) atomic parts per million (appm). Results are compared with those reported previously for specimens containing 0 and 94 (measured) appm helium

  19. Simulator of the NUMAC SRMN module as virtual instrument for the personnel training of the LVNP

    International Nuclear Information System (INIS)

    Rojas S, A.S.; Rivero G, T.; Ruiz E, J.A.

    2006-01-01

    Inside the training programs of the personnel's of the Laguna Verde Nuclear power station (CNLV) Veracruz, Mexico, is necessary to carry out practices with instruments or electronic equipment contained inside the reactor instrumentation, most of these equipment are in operation and its can be part important of the safety system of the reactor, for what is sometimes impossible to carry out or to modify its operation conditions. The nuclear industry always has offered the improvement of the systems and equipment that compose the nuclear power station. In this context, during the last years, they have been carried out diverse upgrades of the systems in the CNLV, among them they are the dedicated measurement equipment and nuclear control (NUMAC, by its initials in English). It would be desirable to have a support tool that allows the interactive knowledge of these systems elevating by this way the quality of the personnel's preparation. In this work the NUMAC system by means of a virtual instrument, which has the facilities of developing practices and programs of training is presented. The NUMAC (Nuclear Measurement Analysis and Control), its are controllers connected to the SIIP (Integral System of Process Information), of the following types: RWM (Rod Worth Minimizer), LDM (Leak Detection Monitor), ATCU (Automatic TIP Control Unit [TIP: Traversing In-Core Probe]), LCR (Log Count Rate), LRM (Logarithmic Radiation Monitor), PRNM Power Range Neutron Monitor, SRNM (Start-up Range Neutron Monitor). The NUMAC, are instruments for monitoring and control of the reactor whose introduction is relatively recent, these instruments are connected to the SIIP, its are microprocessors similar to the industrial computers, dedicated to measure and to control systems in the plant. By safety, the control is programmed and it is configured locally in each processor and in the workstations of the SIIP, only the acquired information of these devices is presented. This work describes the

  20. Management of wound infection after lumbar arthrodesis maintaining the instrumentation

    Directory of Open Access Journals (Sweden)

    Asdrubal Falavigna

    2015-06-01

    Full Text Available OBJECTIVE: To determinate whether a surgical protocol with immediate extensive debridement, closed irrigation system and antibiotic therapy would be effective to achieve healing of deep wound infection without removing the instrumentation.METHODS: Prospective cohort study with 19 patients presenting degenerative spinal stenosis or degenerative spondylolisthesis, who developed infection after posterior lumbar arthrodesis. The diagnosis was confirmed by a microbial culture from subfascial lumbar fluid and/or blood. Patients were treated with a protocol of wound exploration, extensive flushing and debridement, placement of a closed irrigation system that was maintained for five days and intravenous antibiotics. The instrumentation system was not removed.RESULTS: Mean age was 59.31 (±13.17 years old and most patients were female (94.7%; 18/19. The mean period for the identification of the infection was 2 weeks and 57.9% underwent a single wound exploration. White blood count, erythrocyte sedimentation rate and C-reactive protein showed a significant decrease post-treatment when compared to pre-treatment values. A significant reduction of erythrocyte sedimentation rate and C-reactive protein was also observed at the final evaluation. No laboratory test was useful to predict the need for more than one debridement.CONCLUSION: Patients with wound infection after instrumentation can be treated without removal of the instrumentation through wound exploration, extensive flushing, debridement of necrotic tissue, closed irrigation system during 5 days and proper antibiotic therapy. The blood tests were not useful to predict surgical re-interventions.

  1. Nuclear qualified in-containment electrical connectors and method of connecting electrical conductors

    Science.gov (United States)

    Powell, J. G.

    1991-01-01

    A nuclear qualified in-containment electrical connection comprises an insulated, sheathed instrument lead having electrical conductors extending from one end thereof to provide two exposed lead wires, a watertight cable having electrical conducting wires therein and extending from one end of the cable to provide two lead wires therefrom, two butt splice connectors each connecting the ends of respective ones of the lead wires from the instrument lead and cable, a length of heat shrinkable plastic tubing positioned over each butt splice connector and an adjacent portion of a respective lead wire from the cable and heat shrunk into position, a length of heat shrinkable plastic tubing on the end portion of the instrument lead adjacent the lead wires therefrom and heat shrunk thereon and a length of outer heat shrinkable plastic tubing extending over the end portion of the instrument lead and the heat shrinkable tubing thereon and over the butt splice connectors and a portion of the cable adjacent the cable lead lines, the outer heat shrinkable tubing being heat shrunk into sealing position on the instrument lead and cable.

  2. A performance-oriented and risk-based regulation for containment testing

    International Nuclear Information System (INIS)

    Dey, M.

    1994-01-01

    In August 1992, the NRC initiated a major initiative to develop requirements for containment testing that are less prescriptive, and more performance-oriented and risk-based. This action was a result of public comments and several studies that concluded that the economic burden of certain, present containment testing requirements are not commensurate with their safety benefits. The rulemaking will include consideration of relaxing the allowable containment leakage rate, increasing the interval for the integrated containment test, and establishing intervals for the local containment leak rate tests based on their performance. A study has been conducted to provide technical information for establishing the performance criteria for containment tests, the allowable leakage rate, commensurate with its significance to total public risk. The study used results of a recent comprehensive study conducted by the NRC, NUREG-1150, 'Severe Accident Risks: An Assessment for Five U.S. Nuclear Power Plants,' to examine the sensitivity of containment leakage to public risk. Risk was found to be insensitive to containment leakage rate up to levels of about 100 percent-volume per day for certain types of containments. PRA methods have also been developed to establish risk-based intervals for containment tests based on their past experience. Preliminary evaluations show that increasing the interval for the integrated containment leakage test from three times to once every ten years would have an insignificant impact on public risk. Preliminary analyses of operational experience data for local leak rate tests show that performance-based testing, valves and penetrations that perform well are tested less frequently, is feasible with marginal impact on safety. The above technical studies are being used to develop efficient (cost-effective) requirements for containment tests. (author). 4 refs., 2 figs

  3. Experiences in integrated leak rate measurements

    International Nuclear Information System (INIS)

    Shirk, R.E.

    1982-01-01

    During a hypothetical design basis accident for nuclear power plants, the reactor containment system is relied upon to maintain radioactive exposure limits below acceptable limits. Integrated leak rate testing is a means of verifying that the leakage of radioactivity material from the reactor containment will be below allowable limits. Leakage rate computations are based on the ideal gas law. The absolute method of leakage rate testing utilizing mass point method of data analysis is recommended. Integrated leak rate testing data is obtained from pressure, drybulb temperature, dewpoint temperature, and flow measuring systems. Test data does not support the usual leakage (flow) - pressure square root relationship. The major source of potential leakage from the reactor containment is reactor containment isolation valves

  4. The Mistra experiment for field containment code validation first results

    International Nuclear Information System (INIS)

    Caron-Charles, M.; Blumenfeld, L.

    2001-01-01

    The MISTRA facility is a large scale experiment, designed for the purpose of thermal-hydraulics multi-D codes validation. A short description of the facility, the set up of the instrumentation and the test program are presented. Then, the first experimental results, studying helium injection in the containment and their calculations are detailed. (author)

  5. Quality of care: from the perspective of elderly people: the QUOTE-Elderly instrument.

    NARCIS (Netherlands)

    Sixma, H.J.; Campen, C. van; Kerssens, J.J.; Peters, L.

    2000-01-01

    Background: patient views on the quality of care are usually assessed by means of patient satisfaction questionnaires. Aim: to develop an instrument that would: (i)produce data to the expectations and experiences of non-institutionalized elderly people, (ii) contain items that has been formulated in

  6. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  7. The contextual effects of social capital on health: a cross-national instrumental variable analysis.

    Science.gov (United States)

    Kim, Daniel; Baum, Christopher F; Ganz, Michael L; Subramanian, S V; Kawachi, Ichiro

    2011-12-01

    Past research on the associations between area-level/contextual social capital and health has produced conflicting evidence. However, interpreting this rapidly growing literature is difficult because estimates using conventional regression are prone to major sources of bias including residual confounding and reverse causation. Instrumental variable (IV) analysis can reduce such bias. Using data on up to 167,344 adults in 64 nations in the European and World Values Surveys and applying IV and ordinary least squares (OLS) regression, we estimated the contextual effects of country-level social trust on individual self-rated health. We further explored whether these associations varied by gender and individual levels of trust. Using OLS regression, we found higher average country-level trust to be associated with better self-rated health in both women and men. Instrumental variable analysis yielded qualitatively similar results, although the estimates were more than double in size in both sexes when country population density and corruption were used as instruments. The estimated health effects of raising the percentage of a country's population that trusts others by 10 percentage points were at least as large as the estimated health effects of an individual developing trust in others. These findings were robust to alternative model specifications and instruments. Conventional regression and to a lesser extent IV analysis suggested that these associations are more salient in women and in women reporting social trust. In a large cross-national study, our findings, including those using instrumental variables, support the presence of beneficial effects of higher country-level trust on self-rated health. Previous findings for contextual social capital using traditional regression may have underestimated the true associations. Given the close linkages between self-rated health and all-cause mortality, the public health gains from raising social capital within and across

  8. Content and ratings of mature-rated video games.

    Science.gov (United States)

    Thompson, Kimberly M; Tepichin, Karen; Haninger, Kevin

    2006-04-01

    To quantify the depiction of violence, blood, sexual themes, profanity, substances, and gambling in video games rated M (for "mature") and to measure agreement between the content observed and the rating information provided to consumers on the game box by the Entertainment Software Rating Board. We created a database of M-rated video game titles, selected a random sample, recorded at least 1 hour of game play, quantitatively assessed the content, performed statistical analyses to describe the content, and compared our observations with the Entertainment Software Rating Board content descriptors and results of our prior studies. Harvard University, Boston, Mass. Authors and 1 hired game player. M-rated video games. Percentages of game play depicting violence, blood, sexual themes, gambling, alcohol, tobacco, or other drugs; use of profanity in dialogue, song lyrics, or gestures. Although the Entertainment Software Rating Board content descriptors for violence and blood provide a good indication of such content in the game, we identified 45 observations of content that could warrant a content descriptor in 29 games (81%) that lacked these content descriptors. M-rated video games are significantly more likely to contain blood, profanity, and substances; depict more severe injuries to human and nonhuman characters; and have a higher rate of human deaths than video games rated T (for "teen"). Parents and physicians should recognize that popular M-rated video games contain a wide range of unlabeled content and may expose children and adolescents to messages that may negatively influence their perceptions, attitudes, and behaviors.

  9. Evaluation the complex lithologies in the oil well using spectral density instrument

    International Nuclear Information System (INIS)

    Zivanov, M.; Martinovic, S.; Jakovljevic, B.

    1991-01-01

    Spectral density instrument for logging in the oil wells, beside density, measure photo electrical cross section. The principles of logging are discussed of modern spectral density. Results of logging are used dor determining the complex lithology in the oil well. With this instrument are obtained the more accurate and reliable logging results and better lithology rate and reliable logging results and better lithology determination in the formations. (author)

  10. Validity and reliability of the Mastication Observation and Evaluation (MOE) instrument.

    Science.gov (United States)

    Remijn, Lianne; Speyer, Renée; Groen, Brenda E; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2014-07-01

    The Mastication Observation and Evaluation (MOE) instrument was developed to allow objective assessment of a child's mastication process. It contains 14 items and was developed over three Delphi rounds. The present study concerns the further development of the MOE using the COSMIN (Consensus based Standard for the Selection of Measurement Instruments) and investigated the instrument's internal consistency, inter-observer reliability, construct validity and floor and ceiling effects. Consumption of three bites of bread and biscuit was evaluated using the MOE. Data of 59 healthy children (6-48 mths) and 38 children (bread) and 37 children (biscuit) with cerebral palsy (24-72 mths) were used. Four items were excluded before analysis due to zero variance. Principal Components Analysis showed one factor with 8 items. Internal consistency was >0.70 (Chronbach's alpha) for both food consistencies and for both groups of children. Inter-observer reliability varied from 0.51 to 0.98 (weighted Gwet's agreement coefficient). The total MOE scores for both groups showed normal distribution for the population. There were no floor or ceiling effects. The revised MOE now contains 8 items that (a) have a consistent concept for mastication and can be scored on a 4-point scale with sufficient reliability and (b) are sensitive to stages of chewing development in young children. The removed items are retained as part of a criterion referenced list within the MOE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Selecting Suicide Ideation Assessment Instruments: A Meta-Analytic Review

    Science.gov (United States)

    Erford, Bradley T.; Jackson, Jessica; Bardhoshi, Gerta; Duncan, Kelly; Atalay, Zumra

    2018-01-01

    Psychometric meta-analyses and reviews were provided for four commonly used suicidal ideation instruments: the Beck Scale for Suicide Ideation, the Suicide Ideation Questionnaire, the Suicide Probability Scale, and Columbia--Suicide Severity Rating Scale. Practical and technical issues and best use recommendations for screening and outcome…

  12. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  13. Corrosion of radioactive waste containers, case of a container made of low allow steel

    International Nuclear Information System (INIS)

    Bataillon, C.; Musy, C.; Roy, M.

    2001-01-01

    The following topics were dealt with: radioactive waste concept ANDRA, low alloy steel (XC38) container corrosion under representative storage conditions, corrosion rate and passivation effects, micrographic investigations

  14. SuperAGILE onboard electronics and ground test instrumentation

    International Nuclear Information System (INIS)

    Pacciani, Luigi; Morelli, Ennio; Rubini, Alda; Mastropietro, Marcello; Porrovecchio, Geiland; Costa, Enrico; Del Monte, Ettore; Donnarumma, Immacolata; Evangelista, Yuri; Feroci, Marco; Lazzarotto, Francesco; Rapisarda, Massimo; Soffitta, Paolo

    2007-01-01

    In this paper we describe the electronics of the SuperAGILE X-ray imager on-board AGILE satellite and the instrumentation developed to test and improve the Front-End and digital electronics of the flight model of the imager. Although the working principle of the instrument is very well established, and the conceptual scheme simple, the budget and mechanical constraints of the AGILE small mission made necessary the introduction of new elements in SuperAGILE, regarding both the mechanics and the electronics. In fact the instrument is contained in a ∼44x44x16cm 3 volume, but the required performance is quite ambitious, leading us to equip a sensitive area of ∼1350cm 2 with 6144 Silicon μstrips detectors with a pitch of 121μm and a total length of ∼18.2cm. The result is a very light and power-cheap imager with a good sensitivity (∼15mCrab in 1 day in 15-45keV), high angular resolution (6arcmin) and gross spectral resolution. The test-equipment is versatile, and can be easily modified to test FEE based on self-triggered, data-driven and sparse-readout ASICs such as XA family chips

  15. Installation and instrumentation of a test-trench facility in the unsaturated zone at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Lewis, B.D.

    1984-01-01

    Two simulated waste trenches have been constructed just north of the Radioactive Waste Management Complex (RWMC) at the Idaho National Engineering Laboratory. Sections of culvert occupy part of these trenches and are accessible through vertical caissons. These structures therefore allow personnel access for installing instrumentation, maintenance, and observation. Instrumented simulated waste containers will occupy the remainder of the trenches, in order that soil-moisture migration may be observed in relation to waste container forms. The installation will be used to determine, under actual and simulated conditions at a shallow land-burial site in an arid environment, typical soil-moisture content, unsaturated hydraulic conductivity, matric potential, soil-moisture flux, and soil-moisture velocity. The information will be collected using instrumentation located in disturbed and undisturbed soils, simulated waste containers, and the underlying basalt layer. Therefore, data collected from the facility will (a) help characterize the hydrogeologic and geochemical properties of the surficial sediments, (b) contribute to understanding the hydrogeologic phenomena associated with buried waste (including leachate formation and radionuclide migration), (c) provide information on water and solute movement at the sediment/basalt interface, and (d) be used in a radionuclide migration model

  16. UPTF test instrumentation. Measurement system identification, engineering units and computed parameters

    International Nuclear Information System (INIS)

    Sarkar, J.; Liebert, J.; Laeufer, R.

    1992-11-01

    This updated version of the previous report /1/ contains, besides additional instrumentation needed for 2D/3D Programme, the supplementary instrumentation in the inlet plenum of SG simulator and hot and cold leg of broken loop, the cold leg of intact loops and the upper plenum to meet the requirements (Test Phase A) of the UPTF Programme, TRAM, sponsored by the Federal Minister of Research and Technology (BMFT) of the Federal Republic of Germany. For understanding, the derivation and the description of the identification codes for the entire conventional and advanced measurement systems classifying the function, and the equipment unit, key, as adopted in the conventional power plants, have been included. Amendments have also been made to the appendices. In particular, the list of measurement systems covering the measurement identification code, instrument, measured quantity, measuring range, band width, uncertainty and sensor location has been updated and extended to include the supplementary instrumentation. Beyond these amendments, the uncertainties of measurements have been precisely specified. The measurement identification codes which also stand for the identification of the corresponding measured quantities in engineering units and the identification codes derived therefrom for the computed parameters have been adequately detailed. (orig.)

  17. AP600 containment purge radiological analysis

    Energy Technology Data Exchange (ETDEWEB)

    O`Connor, M.; Schulz, J.; Tan, C. [Bechtel Power Corporation (United States)] [and others

    1995-02-01

    The AP600 Project is a passive pressurized water reactor power plant which is part of the Design Certification and First-of-a-Kind Engineering effort under the Advanced Light Water Reactor program. Included in this process is the design of the containment air filtration system which will be the subject of this paper. We will compare the practice used by previous plants with the AP600 approach to meet the goals of industry standards in sizing the containment air filtration system. The radiological aspects of design are of primary significance and will be the focus of this paper. The AP600 Project optimized the design to combine the functions of the high volumetric flow rate, low volumetric flow rate, and containment cleanup and other filtration systems into one multi-functional system. This achieves a more simplified, standardized, and lower cost design. Studies were performed to determine the possible concentrations of radioactive material in the containment atmosphere and the effectiveness of the purge system to keep concentrations within 10CFR20 limits and within offsite dose objectives. The concentrations were determined for various reactor coolant system leakage rates and containment purge modes of operation. The resultant concentrations were used to determine the containment accessibility during various stages of normal plant operation including refueling. The results of the parametric studies indicate that a dual train purge system with a capacity of 4,000 cfm per train is more than adequate to control the airborne radioactivity levels inside containment during normal plant operation and refueling, and satisfies the goals of ANSI/ANS-56.6-1986 and limits the amount of radioactive material released to the environment per ANSI/ANS 59.2-1985 to provide a safe environment for plant personnel and offsite residents.

  18. New analytical portable instrument for microchip electrophoresis with electrochemical detection.

    Science.gov (United States)

    Fernández-la-Villa, Ana; Pozo-Ayuso, Diego F; Castaño-Alvarez, Mario

    2010-08-01

    A new portable instrument that includes a high voltage power supply, a bipotentiostat, and a chip holder has been especially developed for using microchips electrophoresis with electrochemical detection. The main unit of the instrument has dimensions of 150 x 165 x 70 mm (wxdxh) and consists of a four-outputs high voltage power supply with a maximum voltage of +/-3 KV and an acquisition system with two channels for dual amperometric (DC or pulsed amperometric detection) detection. Electrochemical detection has been selected as signal transduction method because it is relatively easily implemented, since nonoptical elements are required. The system uses a lithium-ion polymer battery and it is controlled from a desktop or laptop PC with a graphical user interface based on LabVIEW connected by serial RS232 or Bluetooth. The last part of the system consists of a reusable chip holder for housing the microchips, which contain all the electrical connections and reservoirs for making the work with microchips easy. The performance of the new instrument has been evaluated and compared with other commercially available apparatus using single- and dual-channel pyrex microchips for the separation of the neurotransmitters dopamine, epinephrine, and 3,4-dihydroxy-L-phenyl-alanine. The reduction of the size of the instrument has not affected the good performance of the separation and detection using microchips electrophoresis with electrochemical detection. Moreover, the new portable instrument paves the way for in situ analysis making the use of microchips electrophoresis easier.

  19. Influence of Color of Polythene Container and three Spawn rates on ...

    African Journals Online (AJOL)

    a

    2012-04-16

    Apr 16, 2012 ... and based on completely randomized design (CRD) with three replications. Factors were different colour of polythene container (blue, yellow, transparent and green) and various levels of spawn (2.5, 4 and 5% wet weight substrate bases). There was significant difference in the yields from different spawn.

  20. The Atacama Cosmology Telescope: Instrument

    Science.gov (United States)

    Thornton, Robert J.; Atacama Cosmology Telescope Team

    2010-01-01

    The 6-meter Atacama Cosmology Telescope (ACT) is making detailed maps of the Cosmic Microwave Background at Cerro Toco in northern Chile. In this talk, I focus on the design and operation of the telescope and its commissioning instrument, the Millimeter Bolometer Array Camera. The camera contains three independent sets of optics that operate at 148 GHz, 217 GHz, and 277 GHz with arcminute resolution, each of which couples to a 1024-element array of Transition Edge Sensor (TES) bolometers. I will report on the camera performance, including the beam patterns, optical efficiencies, and detector sensitivities. Under development for ACT is a new polarimeter based on feedhorn-coupled TES devices that have improved sensitivity and are planned to operate at 0.1 K.

  1. Design and development of control instrumentation for the superconducting Linear Accelerator

    International Nuclear Information System (INIS)

    Joshi, Gopal; Kapatral, R.S.; Jha, K.; Rathod, N.C.; Sujo, C.I.; Ananthakrishnan, T.S.; Narsaiah, A.; Ghodgaonkar, M.D.; Kataria, S.K.; Singh, S.K.

    2001-01-01

    Electronics Division, BARC is developing the required control instrumentation for the Linear Accelerator (LINAC) coming up at TIFR. This consists of RF systems, CAMAC instruments and the Control and Information System. The control system consists of several identical Local Control Stations (LCS) connected over a LAN to a Main Control Station (MCS). Each LCS consists of a PC, CAMAC crates with functional Modules and RF systems. The MCS will contain two PCs running identical software. Each LCS will cater to two LINAC module each consisting of one cryostat and four resonators. This paper discusses different systems developed and under development in the Electronics Division which play an important role in the control of the LINAC. (author)

  2. Acidithiobacillus thiooxidans secretome containing a newly described lipoprotein Licanantase enhances chalcopyrite bioleaching rate

    Science.gov (United States)

    Bobadilla Fazzini, Roberto A.; Levican, Gloria

    2010-01-01

    The nature of the mineral–bacteria interphase where electron and mass transfer processes occur is a key element of the bioleaching processes of sulfide minerals. This interphase is composed of proteins, metabolites, and other compounds embedded in extracellular polymeric substances mainly consisting of sugars and lipids (Gehrke et al., Appl Environ Microbiol 64(7):2743–2747, 1998). On this respect, despite Acidithiobacilli—a ubiquitous bacterial genera in bioleaching processes (Rawlings, Microb Cell Fact 4(1):13, 2005)—has long been recognized as secreting bacteria (Jones and Starkey, J Bacteriol 82:788–789, 1961; Schaeffer and Umbreit, J Bacteriol 85:492–493, 1963), few studies have been carried out in order to clarify the nature and the role of the secreted protein component: the secretome. This work characterizes for the first time the sulfur (meta)secretome of Acidithiobacillus thiooxidans strain DSM 17318 in pure and mixed cultures with Acidithiobacillus ferrooxidans DSM 16786, identifying the major component of these secreted fractions as a single lipoprotein named here as Licanantase. Bioleaching assays with the addition of Licanantase-enriched concentrated secretome fractions show that this newly found lipoprotein as an active protein additive exerts an increasing effect on chalcopyrite bioleaching rate. Electronic supplementary material The online version of this article (doi:10.1007/s00253-010-3063-8) contains supplementary material, which is available to authorized users. PMID:21191788

  3. The formation of a native-like structure containing eight conserved hydrophobic residues is rate limiting in two-state protein folding of ACBP

    DEFF Research Database (Denmark)

    Kragelund, Birthe Brandt; Osmark, Peter; Neergaard, Thomas B.

    1999-01-01

    The acyl-coenzyme A-binding proteins (ACBPs) contain 26 highly conserved sequence positions. The majority of these have been mutated in the bovine protein, and their influence on the rate of two-state folding and unfolding has been measured. The results identify eight sequence positions, out of 24...... probed, that are critical for fast productive folding. The residues are all hydrophobic and located in the interface between the N- and C-terminal helices. The results suggest that one specific site dominated by conserved hydrophobic residues forms the structure of the productive rate-determining folding...... step and that a sequential framework model can describe the protein folding reaction....

  4. [Instruments of management accounting in german hospitals - potentials for competitive advantage and status quo].

    Science.gov (United States)

    Berens, W; Lachmann, M; Wömpener, A

    2011-03-01

    The aim of this study is to provide an analysis of the status quo for the usage of instruments of management accounting in German hospitals. 600 managing directors of German hospitals were asked to answer a questionnaire about the usage of management accounting instruments in their hospitals. We obtained 121 usable datasets, which are evaluated in this study. A significant increase in the usage of management accounting instruments can be observed over time. The respondents have an overall positive perception of the usage of these instruments. Cost accounting and information systems are among the most widely used instruments, while widely discussed concepts like the balanced scorecard or clinical pathways show surprisingly low usage rates. © Georg Thieme Verlag KG Stuttgart · New York.

  5. A GC Instrument Simulator

    Science.gov (United States)

    Armitage, D. Bruce

    1999-02-01

    the difference between the boiling point of the component and the temperature of the column. The polarity difference between the column packing and the component is also used to modify the retention time. The retention time decreases as the difference between the boiling point of the component and the temperature of the column increases, and retention time increases as the polarity of the component approaches the polarity of the column. If the temperature of the column is too low, a warning message is given and the chromatogram does not show that component. There is no "carry-over" to the next chromatogram, as might be the case for an actual instrument. Carrier-gas flow rate is fixed and is not part of the retention-time calculation. Because of this latter condition and the method used to determine retention time, this simulator is not useful for gas chromatography method development and is not intended for such use. The purpose of the simulator is to give a beginning student experience in what happens as column temperature is varied, why one might need temperature programming, why an autosampler might be useful, and the pitfalls of "smart" integrators. When students make mistakes in instrument setup with the simulator the consequences are not damaging to the simulator but might cause serious problems with a real instrument. Hardware and Software Requirements Hardware and software requirements for A GC Instrument Simulator are shown in Table 1. right> right> Shown (right to left) are the main instrument control window and the manual injection window from A GC Instrument Simulator.

  6. The Relationship between Monetary Policy Rate (MPR) and ...

    African Journals Online (AJOL)

    Government in a bid to regulate the affairs of the economy would always use MPR as one of its instruments; which is an interest rate at which CBN lends to commercial banks and other clients. The execution of one of these instruments at time causes others to response either positively or negatively. In order to find out some ...

  7. Interest Rate Pass-through in Sri Lanka

    OpenAIRE

    Amarasekara, Chandranath

    2005-01-01

    The Central Bank of Sri Lanka has increasingly been relying on interest rates as the instrument for conducting monetary policy. Changes to the key monetary policy variables, the Repo and the Reverse Repo rates, are initially expected to be reflected in the OMO rates and the call money market rates, before being passedthrough to commercial bank retail interest rates. It is important to obtain a good understanding of the speed and magnitude of the interest rate pass-through to make timely monet...

  8. Exchange Rate Regimes – A periodical overview and a critical analysis of exchange rate regimes in Kosovo

    Directory of Open Access Journals (Sweden)

    Flamur Bunjaku

    2015-03-01

    Full Text Available Exchange rate regimes and the monetary policy are the key instruments governments use to achieve their economic and financial objectives. Moreover, due to global financial crisis the latter instruments get more importance. Empirical evidences show that exchange rate regimes in Kosovo and its monetary policy throughout their development were mainly influenced by different political and historical developments. In regard of Euroisation of monetary system in Kosovo it was found that this action generated macro - financial stability in terms of inflation and price fluctuation. However, in terms of microeconomic aspects, the unilateral adaptation of Euro as the official currency of Kosovo failed to provide microeconomic advantages such as to export stimulation, and so forth. The main exchange rate regime systems were discussed focusing in their advantages and disadvantages, and it was concluded that there is no commonly accepted theory regarding the optimality of exchange rate regimes. In addition, the global financial crisis impact in the financial system of Kosovo is also discussed and it was found that negative impacts of global financial crisis were moderate and indirect.

  9. Independent Orbiter Assessment (IOA): Assessment of instrumental subsystem FMEA/CIL

    Science.gov (United States)

    Gardner, J. R.; Addis, A. W.

    1988-01-01

    The McDonnell Douglas Astronautics Company (MDAC) was selected in June 1986 to perform an Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL). The IOA effort first completed an analysis of the Instrumentation hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter Instrumentation hardware are documented. The IOA product for Instrumentation analysis consisted of 107 failure mode worksheets that resulted in 22 critical items being identified. Comparison was made to the Pre 51-L NASA baseline with 14 Post 51-L FMEAs added, which consists of 96 FMEAs and 18 CIL items. This comparison produced agreement on all but 25 FMEAs which caused differences in 5 CIL items.

  10. VLF and X-ray Instruments for Stratospheric Balloons: ABOVE2 and EPEx

    Science.gov (United States)

    Cully, C. M.; Galts, D.; Patrick, M.; Duffin, C.; Jang, A. C.; Pitzel, J.; Trumpour, T.; McCarthy, M.; Milling, D. K.

    2017-12-01

    The ABOVE2 (2016) and EPEx (2018) stratospheric balloon missions are designed to study energetic electrons precipitating from the radiation belts into the atmosphere. The payloads include instruments that measure Very Low Frequency (VLF) magnetic and electric fields, and bremsstrahlung X-rays. The ABOVE2 VLF instrument is an FPGA-based design with >200 kHz sampling rates, sub-microsecond timing accuracy and onboard spectral processing, designed in a Cubesat-friendly format. The EPEx X-ray instrument is a hard X-ray imaging system, also in a Cubesat-friendly format, incorporating a commercially-available Cadmium-Zinc-Telluride module. The imager is sufficiently lightweight that we can launch it on-demand with low-volume latex balloons. I will discuss the design and performance of both instruments, and present data from the ABOVE2 flights.

  11. Instrument evaluation no.14: Wallac laboratory contamination meter RD 11

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-01-01

    An instrument for measuring low level contamination and consisting of a detachable Geiger-Muller tube probe, connected to a rate meter by a coiled extensible tube is described. Facilities and controls, performance, electrical, environmental and mechanical characteristics are included. (UK)

  12. Core outcome measurement instruments for clinical trials in nonspecific low back pain

    Science.gov (United States)

    Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A.; Buchbinder, Rachelle; Corbin, Terry P.; Costa, Leonardo O.P.; Foster, Nadine E.; Grotle, Margreth; Koes, Bart W.; Kovacs, Francisco M.; Lin, C.-W. Christine; Maher, Chris G.; Pearson, Adam M.; Peul, Wilco C.; Schoene, Mark L.; Turk, Dennis C.; van Tulder, Maurits W.; Terwee, Caroline B.; Ostelo, Raymond W.

    2018-01-01

    Abstract To standardize outcome reporting in clinical trials of patients with nonspecific low back pain, an international multidisciplinary panel recommended physical functioning, pain intensity, and health-related quality of life (HRQoL) as core outcome domains. Given the lack of a consensus on measurement instruments for these 3 domains in patients with low back pain, this study aimed to generate such consensus. The measurement properties of 17 patient-reported outcome measures for physical functioning, 3 for pain intensity, and 5 for HRQoL were appraised in 3 systematic reviews following the COSMIN methodology. Researchers, clinicians, and patients (n = 207) were invited in a 2-round Delphi survey to generate consensus (≥67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In round 1, consensus was achieved on the Oswestry Disability Index version 2.1a for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In round 2, a consensus was reached on an NRS version with a 1-week recall period (96% agreement). Various participants requested 1 free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: Oswestry Disability Index version 2.1a or 24-item Roland-Morris Disability Questionnaire for physical functioning, NRS for pain intensity, and SF12 or 10-item PROMIS Global Health form for HRQoL. Further studies need to fill the evidence gaps on the measurement properties of these and other instruments. PMID:29194127

  13. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A wide variety of portable survey instruments employing GM, ionization chamber and scintillation detectors exist for the measurement of gamma exposure rates. Often these same survey instruments are used for monitoring beta fields. This is done by making measurements with and without a removable shield which is intended to shield out the non-penetrating component (beta) of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. In many instances correction factors have been derived, that if properly applied, can reduce these errors substantially. However, this requires some knowledge of the beta spectra, calibration techniques and source geometry. This paper discusses some aspects of the proper use of instruments for beta measurements including the application of appropriate correction factors. Ionization type instruments are commonly used to measure beta dose rates. Through design and calibration these instruments will give an accurate reading only for uniform irradiation of the detection volume. Often in the field it is not feasible to meet these conditions. Large area uniform distributions of activity are not generally encountered and it is not possible to use large source-to-detector distances due to beta particle absorption in air. An example of correction factors required for various point sources is presented when a cutie pie ionization chamber is employed. The instrument reading is multiplied by the appropriate correction factor to obtain the dose rate at the window. When a different detector is used or for other geometries, a different set of correction factors must be used

  14. Building the BIKE: Development and Testing of the Biotechnology Instrument for Knowledge Elicitation (BIKE)

    Science.gov (United States)

    Witzig, Stephen B.; Rebello, Carina M.; Siegel, Marcelle A.; Freyermuth, Sharyn K.; Izci, Kemal; McClure, Bruce

    2014-10-01

    Identifying students' conceptual scientific understanding is difficult if the appropriate tools are not available for educators. Concept inventories have become a popular tool to assess student understanding; however, traditionally, they are multiple choice tests. International science education standard documents advocate that assessments should be reform based, contain diverse question types, and should align with instructional approaches. To date, no instrument of this type targeting student conceptions in biotechnology has been developed. We report here the development, testing, and validation of a 35-item Biotechnology Instrument for Knowledge Elicitation (BIKE) that includes a mix of question types. The BIKE was designed to elicit student thinking and a variety of conceptual understandings, as opposed to testing closed-ended responses. The design phase contained nine steps including a literature search for content, student interviews, a pilot test, as well as expert review. Data from 175 students over two semesters, including 16 student interviews and six expert reviewers (professors from six different institutions), were used to validate the instrument. Cronbach's alpha on the pre/posttest was 0.664 and 0.668, respectively, indicating the BIKE has internal consistency. Cohen's kappa for inter-rater reliability among the 6,525 total items was 0.684 indicating substantial agreement among scorers. Item analysis demonstrated that the items were challenging, there was discrimination among the individual items, and there was alignment with research-based design principles for construct validity. This study provides a reliable and valid conceptual understanding instrument in the understudied area of biotechnology.

  15. Flyover Modeling of Planetary Pits - Undergraduate Student Instrument Project

    Science.gov (United States)

    Bhasin, N.; Whittaker, W.

    2015-12-01

    On the surface of the moon and Mars there are hundreds of skylights, which are collapsed holes that are believed to lead to underground caves. This research uses Vision, Inertial, and LIDAR sensors to build a high resolution model of a skylight as a landing vehicle flies overhead. We design and fabricate a pit modeling instrument to accomplish this task, implement software, and demonstrate sensing and modeling capability on a suborbital reusable launch vehicle flying over a simulated pit. Future missions on other planets and moons will explore pits and caves, led by the technology developed by this research. Sensor software utilizes modern graph-based optimization techniques to build 3D models using camera, LIDAR, and inertial data. The modeling performance was validated with a test flyover of a planetary skylight analog structure on the Masten Xombie sRLV. The trajectory profile closely follows that of autonomous planetary powered descent, including translational and rotational dynamics as well as shock and vibration. A hexagonal structure made of shipping containers provides a terrain feature that serves as an appropriate analog for the rim and upper walls of a cylindrical planetary skylight. The skylight analog floor, walls, and rim are modeled in elevation with a 96% coverage rate at 0.25m2 resolution. The inner skylight walls have 5.9cm2 color image resolution and the rims are 6.7cm2 with measurement precision superior to 1m. The multidisciplinary student team included students of all experience levels, with backgrounds in robotics, physics, computer science, systems, mechanical and electrical engineering. The team was commited to authentic scientific experimentation, and defined specific instrument requirements and measurable experiment objectives to verify successful completion.This work was made possible by the NASA Undergraduate Student Instrument Project Educational Flight Opportunity 2013 program. Additional support was provided by the sponsorship of an

  16. Simulation of containment phenomena during the Phebus FPT1 test with the CONTAIN code

    International Nuclear Information System (INIS)

    Kljenak, I.; Mavko, B.

    2002-01-01

    Thermal-hydraulic and aerosol phenomena which occurred in the containment vessel of the Phebus integral experimental facility during the first 30000 s of the Phebus FPT1 test were simulated with the CONTAIN thermal-hydraulic computer code. A single-cell input model of the vessel was developed, and boundary and initial conditions that were determined during the experiment were applied. The comparison of experimental and calculated results shows that, although the atmosphere temperature was well simulated, the calculated condensation rate was apparently too high, resulting in a lower pressure of the containment atmosphere. The aerosol deposition process was well simulated.(author)

  17. Determination of Lowest Achievable Emission Rate for Coors Container Corporation

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  18. Electronic constant current and current pulse signal generator for nuclear instrumentation testing

    International Nuclear Information System (INIS)

    Brown, R.A.

    1994-01-01

    Circuitry is described for testing the ability of an intermediate range nuclear instrument to detect and measure a constant current and a periodic current pulse. The invention simulates the resistance and capacitance of the signal connection of a nuclear instrument ion chamber detector and interconnecting cable. An LED flasher/oscillator illuminates an LED at a periodic rate established by a timing capacitor and circuitry internal to the flasher/oscillator. When the LED is on, a periodic current pulse is applied to the instrument. When the LED is off, a constant current is applied. An inductor opposes battery current flow when the LED is on. 1 figures

  19. Optical Methods For Automatic Rating Of Engine Test Components

    Science.gov (United States)

    Pritchard, James R.; Moss, Brian C.

    1989-03-01

    In recent years, increasing commercial and legislative pressure on automotive engine manufacturers, including increased oil drain intervals, cleaner exhaust emissions and high specific power outputs, have led to increasing demands on lubricating oil performance. Lubricant performance is defined by bench engine tests run under closely controlled conditions. After test, engines are dismantled and the parts rated for wear and accumulation of deposit. This rating must be consistently carried out in laboratories throughout the world in order to ensure lubricant quality meeting the specified standards. To this end, rating technicians evaluate components, following closely defined procedures. This process is time consuming, inaccurate and subject to drift, requiring regular recalibration of raters by means of international rating workshops. This paper describes two instruments for automatic rating of engine parts. The first uses a laser to determine the degree of polishing of the engine cylinder bore, caused by the reciprocating action of piston. This instrument has been developed to prototype stage by the NDT Centre at Harwell under contract to Exxon Chemical, and is planned for production within the next twelve months. The second instrument uses red and green filtered light to determine the type, quality and position of deposit formed on the piston surfaces. The latter device has undergone feasibility study, but no prototype exists.

  20. Containing contraceptive costs

    African Journals Online (AJOL)

    April 2015, Vol. 105, No. 4. Containing contraceptive costs. There are about 7 billion people living on our planet. In many countries resources are strained and we seek to slow down the rate of population growth. There are obviously many factors that lead to rapid population growth. Contraceptive methods are an important.

  1. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  2. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  3. Pressure test behaviour of embalse nuclear power plant containment structure

    International Nuclear Information System (INIS)

    Bruschi, S.; Marinelli, C.

    1984-01-01

    It's described the structural behaviour of the containment structure during the pressure test of the Embalse plant (CANDU type, 600MW), made of prestressed concrete with an epoxi liner. Displacement, strain, temperature, and pressure measurements of the containment structure of the Embalse Nuclear Power Plant are presented. The instrumentation set up and measurement specifications are described for all variables of interest before, during and after the pressure test. The analytical models to simulate the heat transfer due to sun heating and air convenction and to predict the associated thermal strains and displacements are presented. (E.G.) [pt

  4. A digital data acquisition system for a time of flight neutron diffuse scattering instrument

    International Nuclear Information System (INIS)

    Venegas, Rafael; Bacza, Lorena; Navarro, Gustavo

    1998-01-01

    Full text. We describe the design of a digital data acquisition system built for acquiring and storing the information produced by a neutron diffuse scattering apparatus. This instrument is based on the analysis of pulsed subthermal neutron which are scattered by a solid or liquid sample, measured as function of the scattered neutron wavelength and momentum direction. The time of flight neutron intensities on 14 different angular detector positions and two fission chambers must be analyzed simultaneously for each neutron burst. A PC controlled data acquisition board system was built based on two parallel multiscannning units, each with its own add-one counting unit, and a common base time generator. The unit plugs onto the ISA bus through an interface card. Two separate counting units were designed, to avoid possible access competition between low counting rate counters at off-axis positions and the higher rate frontal 0 deg and beam monitoring counters. the first unit contains logic for 14 independent and simultaneous multi scaling inputs, with 128 time channels and dwell time per channel of 5, 10 or 20 microseconds. Sweep trigger is synchronized with an electric signal from a coil sensing the rotor. The second unit contains logic for four additional multi scalers using the same external synchronizing signal, similar in all others details to the previously described multi scalers. Basic control routines for the acquisitions were written in C and a program for spectrum display and user interface was written in C ++ for a Windows 3.1 OS. A block diagram of the system is presented

  5. Study Protocol. IDUS -- Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-09-13

    AbstractBackgroundInstrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 – 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice.Methods\\/DesignA multi-centre randomised controlled trial is proposed. The study will take place in two large maternity units in Ireland with a combined annual birth rate of 13,500 deliveries. It will involve 450 nulliparous women undergoing instrumental delivery after 37 weeks gestation. The main outcome measure will be incorrect diagnosis of the fetal head position. A study involving 450 women will have 80% power to detect a 10% difference in the incidence of inaccurate diagnosis of the fetal head position with two-sided 5% alpha.DiscussionIt is both important and timely to evaluate the use of ultrasound to diagnose the fetal head position prior to instrumental delivery before routine use can be advocated. The overall aim is to reduce the incidence of incorrect diagnosis of the fetal head position prior to instrumental delivery and improve the safety of instrumental deliveries.Trial registrationCurrent Controlled Trials ISRCTN72230496

  6. Design of a novel instrument for active neutron interrogation of artillery shells.

    Science.gov (United States)

    Bélanger-Champagne, Camille; Vainionpää, Hannes; Peura, Pauli; Toivonen, Harri; Eerola, Paula; Dendooven, Peter

    2017-01-01

    The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only) for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  7. Container for hydrogen isotopes

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-12

    A container is described for storage, shipping and and dispensing of hydrogen isotopes such as hydrogen, deuterium, tritium, or mixtures of the same. The container is compact, safe against fracture or accident, and is reusable. It consists of an outer housing with suitable inlet and outlet openings and electrical feed elements, the housing containing an activated sorber material in the form, for example of titanium sponge or an activated zirconium aluminate cartridge. The gas to be stored is introduced into the chamber under conditions of heat and vacuum and is retained in the sorber material. Subsequently, it may be released by heating the unit to drive off the stored gas at desired rates.

  8. Container for hydrogen isotopes

    International Nuclear Information System (INIS)

    1976-01-01

    A container is described for storage, shipping and and dispensing of hydrogen isotopes such as hydrogen, deuterium, tritium, or mixtures of the same. The container is compact, safe against fracture or accident, and is reusable. It consists of an outer housing with suitable inlet and outlet openings and electrical feed elements, the housing containing an activated sorber material in the form, for example of titanium sponge or an activated zirconium aluminate cartridge. The gas to be stored is introduced into the chamber under conditions of heat and vacuum and is retained in the sorber material. Subsequently, it may be released by heating the unit to drive off the stored gas at desired rates

  9. Container for hydrogen isotopes

    International Nuclear Information System (INIS)

    Solomon, D.E.

    1977-01-01

    A container for the storage, shipping and dispensing of hydrogen isotopes such as hydrogen, deuterium, tritium, or mixtures of the same which has compactness, which is safe against fracture or accident, and which is reusable is described. The container consists of an outer housing with suitable inlet and outlet openings and electrical feed elements, the housing containing an activated sorber material in the form, for example, of titanium sponge or an activated zirconium aluminate cartridge. The gas to be stored is introduced into the chamber under conditions of heat and vacuum and will be retained in the sorber material. Subsequently, it may be released by heating the unit to drive off the stored gas at desired rates

  10. Mixed-realism simulation of adverse event disclosure: an educational methodology and assessment instrument.

    Science.gov (United States)

    Matos, Francisco M; Raemer, Daniel B

    2013-04-01

    Physicians have an ethical duty to disclose adverse events to patients or families. Various strategies have been reported for teaching disclosure, but no instruments have been shown to be reliable for assessing them.The aims of this study were to report a structured method for teaching adverse event disclosure using mixed-realism simulation, develop and begin to validate an instrument for assessing performance, and describe the disclosure practice of anesthesiology trainees. Forty-two anesthesiology trainees participated in a 2-part exercise with mixed-realism simulation. The first part took place using a mannequin patient in a simulated operating room where trainees became enmeshed in a clinical episode that led to an adverse event and the second part in a simulated postoperative care unit where the learner is asked to disclose to a standardized patient who systematically moves through epochs of grief response. Two raters scored subjects using an assessment instrument we developed that combines a 4-element behaviorally anchored rating scale (BARS) and a 5-stage objective rating scale. The performance scores for elements within the BARS and the 5-stage instrument showed excellent interrater reliability (Cohen's κ = 0.7), appropriate range (mean range for BARS, 4.20-4.47; mean range for 5-stage instrument, 3.73-4.46), and high internal consistency (P realism simulation that engages learners in an adverse event and allows them to practice disclosure to a structured range of patient responses. We have developed a reliable 2-part instrument with strong psychometric properties for assessing disclosure performance.

  11. Assessing variable rate nitrogen fertilizer strategies within an extensively instrument field site using the MicroBasin model

    Science.gov (United States)

    Ward, N. K.; Maureira, F.; Yourek, M. A.; Brooks, E. S.; Stockle, C. O.

    2014-12-01

    The current use of synthetic nitrogen fertilizers in agriculture has many negative environmental and economic costs, necessitating improved nitrogen management. In the highly heterogeneous landscape of the Palouse region in eastern Washington and northern Idaho, crop nitrogen needs vary widely within a field. Site-specific nitrogen management is a promising strategy to reduce excess nitrogen lost to the environment while maintaining current yields by matching crop needs with inputs. This study used in-situ hydrologic, nutrient, and crop yield data from a heavily instrumented field site in the high precipitation zone of the wheat-producing Palouse region to assess the performance of the MicroBasin model. MicroBasin is a high-resolution watershed-scale ecohydrologic model with nutrient cycling and cropping algorithms based on the CropSyst model. Detailed soil mapping conducted at the site was used to parameterize the model and the model outputs were evaluated with observed measurements. The calibrated MicroBasin model was then used to evaluate the impact of various nitrogen management strategies on crop yield and nitrate losses. The strategies include uniform application as well as delineating the field into multiple zones of varying nitrogen fertilizer rates to optimize nitrogen use efficiency. We present how coupled modeling and in-situ data sets can inform agricultural management and policy to encourage improved nitrogen management.

  12. The quality of systematic reviews of health-related outcome measurement instruments.

    Science.gov (United States)

    Terwee, C B; Prinsen, C A C; Ricci Garotti, M G; Suman, A; de Vet, H C W; Mokkink, L B

    2016-04-01

    Systematic reviews of outcome measurement instruments are important tools for the selection of instruments for research and clinical practice. Our aim was to assess the quality of systematic reviews of health-related outcome measurement instruments and to determine whether the quality has improved since our previous study in 2007. A systematic literature search was performed in MEDLINE and EMBASE between July 1, 2013, and June 19, 2014. The quality of the reviews was rated using a study-specific checklist. A total of 102 reviews were included. In many reviews the search strategy was considered not comprehensive; in only 59 % of the reviews a search was performed in EMBASE and in about half of the reviews there was doubt about the comprehensiveness of the search terms used for type of measurement instruments and measurement properties. In 41 % of the reviews, compared to 30 % in our previous study, the methodological quality of the included studies was assessed. In 58 %, compared to 55 %, the quality of the included instruments was assessed. In 42 %, compared to 7 %, a data synthesis was performed in which the results from multiple studies on the same instrument were somehow combined. Despite a clear improvement in the quality of systematic reviews of outcome measurement instruments in comparison with our previous study in 2007, there is still room for improvement with regard to the search strategy, and especially the quality assessment of the included studies and the included instruments, and the data synthesis.

  13. Properties of samples containing natural gas hydrate from the JAPEX/JNOC/GSC Mallik 2L-38 gas hydrate research well, determined using Gas Hydrate And Sediment Test Laboratory Instrument (GHASTLI)

    Science.gov (United States)

    Winters, W.J.

    1999-01-01

    As part of an ongoing laboratory study, preliminary acoustic, strength, and hydraulic conductivity results are presented from a suite of tests conducted on four natural-gas-hydrate-containing samples from the Mackenzie Delta JAPEX/JNOC/GSC Mallik 2L-38 gas hydrate research well. The gas hydrate samples were preserved in pressure vessels during transport from the Northwest Territories to Woods Hole, Massachusetts, where multistep tests were performed using GHASTLI (Gas Hydrate And Sediment Test Laboratory Instrument), which recreates pressure and temperature conditions that are stable for gas hydrate. Properties and changes in sediment behaviour were measured before, during, and after controlled gas hydrate dissociation. Significant amounts of gas hydrate occupied the sample pores and substantially increased acoustic velocity and shear strength.

  14. Validating a new device for measuring tear evaporation rates.

    Science.gov (United States)

    Rohit, Athira; Ehrmann, Klaus; Naduvilath, Thomas; Willcox, Mark; Stapleton, Fiona

    2014-01-01

    To calibrate and validate a commercially available dermatology instrument to measure tear evaporation rate of contact lens wearers. A dermatology instrument was modified by attaching a swim goggle cup such that the cup sealed around the eye socket. Results for the unmodified instrument are dependent on probe area and enclosed volume. Calibration curves were established using a model eye, to account for individual variations in chamber volume and exposed area. Fifteen participants were recruited and the study included a contact lens wear and a no contact lens wear stage. Day and diurnal variation of the measurements were assessed by taking the measurement three times a day over 2 days. The coefficient of repeatability of the measurement was calculated and a linear mixed model assessed the influence of humidity, temperature, contact lens wear, day and diurnal variations on tear evaporation rate. The associations between variables were assessed using Pearson correlation coefficient. Absolute evaporation rates with and without contact lens wear were calculated based on the new calibration. The measurements were most repeatable during the evening with no lens wear (COR = 49 g m⁻² h) and least repeatable during the evening with contact lens wear (COR = 93 g m⁻² h). Humidity (p = 0.007), and contact lens wear (p evaporation rate. However, temperature (p = 0.54) diurnal variation (p = 0.85) and different days (p = 0.65) had no significant effect after controlling for humidity. Tear evaporation rates can be measured using a modified dermatology instrument. Measurements were higher and more variable with lens wear consistent with previous literature. Control of environmental conditions is important as a higher humidity results in a reduced evaporation rate. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  15. A scanning electron microscopic study of smear layer remaining following use of Greater Taper rotary instruments

    Directory of Open Access Journals (Sweden)

    S Soumya

    2011-01-01

    Full Text Available The aim of this in vitro study was to evaluate the smear layer in the root canal following the use of Ni-Ti hand ProTaper, HERO shaper and Twisted rotary instruments. Fifteen freshly extracted single rooted human mandibular premolar teeth were selected. Crowns of all teeth were cut off at the cemento-enamel junction with a carborundum disc. The roots were then randomly divided into three groups of 5 samples each. The working length of all teeth was established by the insertion of an endodontic instrument into the canal until its tip is visible at the apical foramen and then subtracted by 0.5 mm. A sequential crown down technique was carried out in all the three groups as follows: Group-I- Specimens in this group were instrumented with ProTaper Ni-Ti hand instruments. Group-II- Specimens were instrumented with HERO shapers. Group-III - The specimens in this group were instrumented with Twisted rotary instruments. Irrigation was done with 3% NaOCl and 15% EDTA in all the three groups. Teeth were carefully split with hammer and chisel and stored in small labeled bottles containing normal saline until SEM evaluation. Results showed that when comparing ProTaper files, Twisted rotary instruments and HERO shaper instruments, HERO shaper series of rotary instruments showed maximum amount of smear layer followed by the Twisted rotary instruments. Hand instruments produced least amount of smear layer.

  16. Containment performance working group report. Draft report for comment

    International Nuclear Information System (INIS)

    1985-05-01

    Containment buildings for power reactors have been studied to estimate their leak rate as a function of increasing internal pressure and temperature associated with severe accident sequences involving significant core damage. Potential leak paths through containment penetration assemblies (such as equipment hatches, airlocks, purge and vent valves, and electrical penetrations) have been identified and their contributions to leak area for the containment are incorporated into containment response analyses of selected severe accident sequences to predict the containment leak rate and pressure/temperature response as a function of time. Because of lack of reliable experimental data on the leakage behavior of containment penetrations and isolation barriers at pressures beyond their design conditions, an analytical approach has been used to estimate the leakage behavior of components found in specific reference plants that approximately characterize the various containment types

  17. Mechanism and accounting treatment of interest rate swap

    Directory of Open Access Journals (Sweden)

    Prošić Danica

    2015-01-01

    Full Text Available Interest rate swap is a derivative which is today routinely used in the financial sector worldwide. As opposed to that, the swap market in Serbia is reduced to basic versions of interest rate swaps only, and is limited to the major users and providers of services in the financial market. Banks in Serbia have been introducing and promoting interest rate swaps as one of their services rather slowly, which can be deduced from various information on interest rate swaps and non-innovative offers of these instruments. On the other hand, companies are unable to recognize interest rate swaps as instruments of hedge against the negative effects of interest rate fluctuations, and a way to gain competitive edge in relation to other market participants. One of the obstacles for using interest rate swaps is unwillingness of companies to get informed and educated, and to enter new transactions. The volume of conducted swap transactions depends on the level of understanding on the part of their participants. Expansion of knowledge helps bridge the gap between theory and practice, thereby encouraging a more intensive implementation of interest rate swaps in the future.

  18. Selenium-containing indolyl compounds

    DEFF Research Database (Denmark)

    Casaril, Angela M; Ignasiak, Marta T; Chuang, Christine Y

    2017-01-01

    materials, including extracellular matrix (ECM) proteins, within the artery wall. Here we investigated the potential of selenium-containing indoles to afford protection against these oxidants, by determining rate constants (k) for their reaction, and quantifying the extent of damage on isolated ECM proteins......Tyr on HCAEC-ECM were also reduced. These data demonstrate that the novel selenium-containing compounds show high reactivity with oxidants and may modulate oxidative and nitrosative damage at sites of inflammation, contributing to a reduction in tissue dysfunction and atherogenesis....

  19. Monitoring tritium in air containing other beta-emitters using ion chambers

    International Nuclear Information System (INIS)

    Jalbert, R.A.

    1975-01-01

    A flow-through ionization chamber instrument is described which is capable of measuring tritium in air containing high concentrations of other beta emitters. The instrument employs a separate concentric chamber with a thin common wall opaque only to tritium betas. Currents produced in the two chambers are subtracted leaving only the current due to tritium. With a 1.6-l sampling chamber and an 18-s time constant, tritium concentrations of 10 -6 μCi/ml to 10 -4 μCi/ml are measured with 2 sigma confidence in background beta concentrations of 4 x 10 -5 μCi/ml to 0.4 muCi/ml, respectively. (auth)

  20. Validity evidence and reliability of a simulated patient feedback instrument.

    Science.gov (United States)

    Schlegel, Claudia; Woermann, Ulrich; Rethans, Jan-Joost; van der Vleuten, Cees

    2012-01-27

    In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.

  1. The buffer/container experiment design and construction report

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, N.A.; Wan, A.W.L.; Roach, P.J

    1998-03-01

    The Buffer/Container Experiment was a full-scale in situ experiment, installed at a depth of 240 m in granitic rock at AECL's Underground Research Laboratory (URL). The experiment was designed to examine the performance of a compacted sand-bentonite buffer material under the influences of elevated temperature and in situ moisture conditions. Buffer material was compacted in situ into a 5-m-deep, 1.24-m-diameter borehole drilled into the floor of an excavation. A 2.3-m long heater, representative of a nuclear fuel waste container, was placed within the buffer, and instrumentation was installed to monitor changes in buffer moisture conditions, temperature and stress. The experiment was sealed at the top of the borehole and restrained against vertical displacement. Instrumentation in the rock monitored pore pressures, temperatures and rock displacement. The heater was operated at a constant power of 1200 W, which provided a heater skin temperature of approximately 85 degrees C. Experiment construction and installation required two years, followed by two and a half years of heater operation and two years of monitoring the rock conditions during cooling. The construction phase of the experiment included the design, construction and testing of a segmental heater and controller, geological and hydrogeological characterization of the rock, excavation of the experiment room, drilling of the emplacement borehole using high pressure water, mixing and in situ compaction of buffer material, installation of instrumentation in the rock, buffer and on the heater, and the construction of concrete curb and steel vertical restraint system at the top of emplacement borehole. Upon completion of the experiment, decommissioning sampling equipment was designed and constructed and sampling methods were developed which allowed approximately 2000 samples of buffer material to be taken over a 12-day period. Quality assurance procedures were developed for all aspects of experiment

  2. The buffer/container experiment design and construction report

    International Nuclear Information System (INIS)

    Chandler, N.A.; Wan, A.W.L.; Roach, P.J.

    1998-03-01

    The Buffer/Container Experiment was a full-scale in situ experiment, installed at a depth of 240 m in granitic rock at AECL's Underground Research Laboratory (URL). The experiment was designed to examine the performance of a compacted sand-bentonite buffer material under the influences of elevated temperature and in situ moisture conditions. Buffer material was compacted in situ into a 5-m-deep, 1.24-m-diameter borehole drilled into the floor of an excavation. A 2.3-m long heater, representative of a nuclear fuel waste container, was placed within the buffer, and instrumentation was installed to monitor changes in buffer moisture conditions, temperature and stress. The experiment was sealed at the top of the borehole and restrained against vertical displacement. Instrumentation in the rock monitored pore pressures, temperatures and rock displacement. The heater was operated at a constant power of 1200 W, which provided a heater skin temperature of approximately 85 degrees C. Experiment construction and installation required two years, followed by two and a half years of heater operation and two years of monitoring the rock conditions during cooling. The construction phase of the experiment included the design, construction and testing of a segmental heater and controller, geological and hydrogeological characterization of the rock, excavation of the experiment room, drilling of the emplacement borehole using high pressure water, mixing and in situ compaction of buffer material, installation of instrumentation in the rock, buffer and on the heater, and the construction of concrete curb and steel vertical restraint system at the top of emplacement borehole. Upon completion of the experiment, decommissioning sampling equipment was designed and constructed and sampling methods were developed which allowed approximately 2000 samples of buffer material to be taken over a 12-day period. Quality assurance procedures were developed for all aspects of experiment construction

  3. Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID: Frequently asked questions

    Directory of Open Access Journals (Sweden)

    Perrier Laure-Lou

    2005-03-01

    Full Text Available Abstract The exponential development of Patient-Reported Outcomes (PRO measures in clinical research has led to the creation of the Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID to facilitate the selection process of PRO measures in clinical research. The project was initiated by Mapi Research Trust in Lyon, France. Initially called QOLID (Quality of Life Instruments Database, the project's purpose was to provide all those involved in health care evaluation with a comprehensive and unique source of information on PRO and HRQOL measures available through the Internet. PROQOLID currently describes more than 470 PRO instruments in a structured format. It is available in two levels, non-subscribers and subscribers, at http://www.proqolid.org. The first level is free of charge and contains 14 categories of basic useful information on the instruments (e.g. author, objective, original language, list of existing translations, etc.. The second level provides significantly more information about the instruments. It includes review copies of over 350 original instruments, 120 user manuals and 350 translations. Most are available in PDF format. This level is only accessible to annual subscribers. PROQOLID is updated in close collaboration with the instruments' authors on a regular basis. Fifty or more new instruments are added to the database annually. Today, all of the major pharmaceutical companies, prestigious institutions (such as the FDA, the NIH's National Cancer Institute, the U.S. Veterans Administration, dozens of universities, public institutions and researchers subscribe to PROQOLID on a yearly basis. More than 800 users per day routinely visit the database.

  4. [Blending powdered antineoplastic medicine in disposable ointment container].

    Science.gov (United States)

    Miyazaki, Yasunori; Uchino, Tomonobu; Kagawa, Yoshiyuki

    2014-01-01

    On dispensing powdered antineoplastic medicines, it is important to prevent cross-contamination and environmental exposure. Recently, we developed a method for blending powdered medicine in a disposable ointment container using a planetary centrifugal mixer. The disposable container prevents cross-contamination. In addition, environmental exposure associated with washing the apparatus does not arise because no blending blade is used. In this study, we aimed to confirm the uniformity of the mixture and weight loss of medicine in the blending procedure. We blended colored lactose powder with Leukerin(®) or Mablin(®) powders using the new method and the ordinary pestle and mortar method. Then, the blending state was monitored using image analysis. Blending variables, such as the blending ratio (1:9-9:1), container size (35-125 mL), and charging rate (20-50%) in the container were also investigated under the operational conditions of 500 rpm and 50 s. At a 20% charging rate in a 35 mL container, the blending precision of the mixtures was not influenced by the blending ratio, and was less than 6.08%, indicating homogeneity. With an increase in the charging rate, however, the blending precision decreased. The possible amount of both mixtures rose to about 17 g with a 20% charging rate in a 125 mL container. Furthermore, weight loss of medicines with this method was smaller than that with the pestle and mortar method, suggesting that this method is safer for pharmacists. In conclusion, we have established a precise and safe method for blending powdered medicines in pharmacies.

  5. Calibration of radiation protection area monitoring instruments in Sudan

    International Nuclear Information System (INIS)

    Suliman, I.I.; Youssif, B.E.; Beineen, A.A.; Hassan, M.

    2010-01-01

    This article presents results of measurements for the calibration of radiation protection area monitoring instruments carried out during the period 2006-2008 at Secondary Standard Dosimetry Laboratory of Sudan. The work performed included quality assurance measurements, measurements for the dosimeter calibrations and uncertainty analysis. Calibrations were performed using 137 Cs gamma ray sources produced by OB 85 and OB 34/1 gamma calibrators producing air kerma rate that ranged from 10 μGy/h to 50 mGy/h. Area monitoring instruments were calibrated in terms of ambient dose equivalent, H*(10) derived using air kerma to ambient dose equivalent conversion coefficients. Results are presented for 78 area monitoring instruments representing most commonly used types in Sudan. Radioactive check source measurements for the reference chamber showed deviation within 1% limit. The accuracy in the beam output measurements was within 5% internationally considered as acceptable. The results highlighted the importance of radiation protection calibrations. Regulations are further need to ensure safety aspect really meet the required international standards.

  6. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  7. Early modern mathematical instruments.

    Science.gov (United States)

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  8. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  9. The Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH): an observational instrument for assessing the physical environment of institutional settings for persons with dementia.

    Science.gov (United States)

    Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda

    2002-03-01

    To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.

  10. Neutron beam-line shield design for the protein crystallography instrument at the Lujan Center

    International Nuclear Information System (INIS)

    Russell, G.J.; Pitcher, E.J.; Muhrer, G.; Ferguson, P.D.

    2001-01-01

    We have developed a very useful methodology for calculating absolute total (neutron plus gamma-ray) dose equivalent rates for use in the design of neutron beam line shields at a spallation neutron source. We have applied this technique to the design of beam line shields for several new materials science instruments being built at the Manuel Lujan Jr. Neutron Scattering Center. These instruments have a variety of collimation systems and different beam line shielding issues. We show here some specific beam line shield designs for the Protein Crystallography Instrument. (author)

  11. Engineering Analysis of the Recovered SAFOD Borehole Instrumentation

    International Nuclear Information System (INIS)

    Johnson, Wade

    2014-01-01

    The basic data set was acquired during 18 instrumentation setting tests conducted from 2004 through 2007 as part of SAFOD. Active hydrocarbon-rich water invaded the borehole because the borehole had not sealed at the bottom. For this reason, the water in the casing reached the cable head and caused a malfunction. Attempts were made to use better O rings, Krytox oil, and epoxy seal, but all failed. In most of these deployments, standard wire-line was used and the average failure time was two weeks. Based on design review, many improvements such as stainless tube encapsulate electric cables, all-metal seals, and Swageloks were applied. Setting of improved downhole instrument packages was carried out in the autumn of 2008. Still, these instruments could not endure the high temperature environment of 120 degrees Celsius for a long period of time, and all were offline in less than a month. A SAFOD engineering subcommittee was established in 2010 to investigate the problems caused through an examination of the removed instruments. It became clear that fluid including active hydrocarbons had invaded the stainless tubing from the seal part and caused all instruments to fail. Based on the above-mentioned experience, recommendations for the future are as follows. - Perform strict oversight of subcontractors. - Perform robust risk analysis and prepare a risk mitigation plan. - Multiple checks should be performed on points of failure by different people. - If possible, avoid the use of active electronics in environments like those in SAFOD. - Components must be rated for use in the temperature range of the environment in which they are to be used. - If a failure occurs, remove the instrumentation in a timely manner. - The SAFOD POD design was not inherently flawed but poorly implemented. (author)

  12. Decision Analysis and Its Application to the Frequency of Containment Integrated Leakage Rate Tests

    International Nuclear Information System (INIS)

    Apostolakis, George E.; Koser, John P.; Sato, Gaku

    2004-01-01

    For nuclear utilities to become competitive in a deregulated electricity market, costs must be reduced, safety must be maintained, and interested stakeholders must remain content with the decisions being made. One way to reduce costs is to reduce the frequency of preventive maintenance and testing. However, these changes must be weighed against their impact on safety and stakeholder relations. We present a methodology that allows the evaluation of decision options using a number of objectives that include safety, economics, and stakeholder relations. First, the candidate decision options are screened to make sure that they satisfy the relevant regulatory requirements. The remaining options are evaluated using multiattribute utility theory. The results of the formal analysis include a ranking of the options according to their desirability as well as the major reasons that explain this ranking. These results are submitted to a deliberative process in which the decision makers scrutinize the results to ensure that they are meaningful. During the deliberation, new decision options may be formulated based on the insights that the formal analysis provides, as happened in the case study of this paper. This case study deals with the reduction in frequency of the containment integrated leak rate test of a boiling water reactor

  13. Dynamic instrumentation for the K-1600 seismic test facility recommissioning

    International Nuclear Information System (INIS)

    VanHoy, B.W.

    1991-01-01

    Martin Marietta Energy Systems, Inc. is the site contractor to the Department of Energy (DOE) for three Oak Ridge, Tennessee sites, the site in Portsmouth, Ohio, and the site in Paducah, Kentucky. To provide a focus for all natural phenomena engineering related problems, Martin Marietta Energy Systems, Inc. established the Center for Natural Phenomena Engineering under the technical direction of Dr. James E. Beavers. One of the Center's mandates is the determination of seismic properties of building structures containing sensitive processes. This has led to the recommissioning of the K-1600 Seismic Test Facility. The biaxial shake table in this facility was constructed during the eighties for seismic qualification of equipment of the Gas Centrifuge Enrichment Plant. After construction of the plant was terminated the Seismic Test Facility was placed in standby where it was left for six years. The facility's original instrumentation was evaluated versus the required instrumentation to augment its new expanded mission parameters. Instrumentation selection involving technology changes, age and attrition, and the new mission goals are discussed in this paper along with the rationale and budget that were involved with each decision. The testing potential of this facility along with the instrumentation upgrades necessary to accomplish these new tasks for the Center for Natural Phenomena Engineering are considered. New uses such as seismic qualification of equipment utilized in DOE's missions at various sites and waste treatment are proposed. This instrumentation selection is discussed in detail to show the rationale and proposed used of the facility as well as the capabilities of this DOE resource

  14. Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery

    Directory of Open Access Journals (Sweden)

    Murphy Deirdre J

    2012-09-01

    Full Text Available Abstract Background Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 – 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice. Methods/Design A multi-centre randomised controlled trial is proposed. The study will take place in two large maternity units in Ireland with a combined annual birth rate of 13,500 deliveries. It will involve 450 nulliparous women undergoing instrumental delivery after 37 weeks gestation. The main outcome measure will be incorrect diagnosis of the fetal head position. A study involving 450 women will have 80% power to detect a 10% difference in the incidence of inaccurate diagnosis of the fetal head position with two-sided 5% alpha. Discussion It is both important and timely to evaluate the use of ultrasound to diagnose the fetal head position prior to instrumental delivery before routine use can be advocated. The overall aim is to reduce the incidence of incorrect diagnosis of the fetal head position prior to instrumental delivery and improve the safety of instrumental deliveries. Trial registration Current Controlled Trials ISRCTN72230496

  15. Innovative market-based policy instruments for waste management: A case study on shredder residues in Belgium.

    Science.gov (United States)

    Dubois, Maarten; Hoogmartens, Rob; Van Passel, Steven; Van Acker, Karel; Vanderreydt, Ive

    2015-10-01

    In an increasingly complex waste market, market-based policy instruments, such as disposal taxes, can give incentives for sustainable progress while leaving flexibility for innovation. However, implementation of disposal taxes is often criticised by domestic waste handlers that fear to be outcompeted by competitors in other countries. The article discusses three innovative market-based instruments that limit the impact on international competitiveness: Tradable recycling credits, refunded disposal taxes and differentiated disposal taxes. All three instruments have already been implemented for distinct environmental policies in Europe. In order to illustrate how these instruments can be used for waste policy, the literature review is complemented with a case study on shredder residues from metal-containing waste streams in Belgium. The analysis shows that a conventional disposal tax remains the most efficient, simple and transparent instrument. However, if international competition is a significant issue or if political support is weak, refunded and differentiated disposal taxes can have an added value as second-best instruments. Tradable recycling credits are not an appropriate instrument for use in small waste markets with market power. In addition, refunded taxes create similar incentives, but induce lower transactions costs. © The Author(s) 2015.

  16. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  17. The Thermal-hydraulic Performance Test Report for the Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan

    2008-09-15

    This report presents the results of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of the double cooled annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, corresponding to the pressure drop of 200 kPa is measured to be about 9.72 kg/sec. Vibration frequency for the non-instrumented rig ranges from 5.0 to 10.7 kg/s. RMS(Root Mean Square) displacement for non-instrumented rig is less than 11.73 m, and the maximum displacement is less than 54.87m. The flow rate for endurance test were 10.5 kg/s, which was 110% of 9.72 kg/s. And the endurance test was carried out for 3 days. The test results found not to the wear and satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented rig. This test was performed at the FIVPET facility.

  18. Biosensors for EVA: Improved Instrumentation for Ground-based Studies

    Science.gov (United States)

    Soller, B.; Ellerby, G.; Zou, F.; Scott, P.; Jin, C.; Lee, S. M. C.; Coates, J.

    2010-01-01

    During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared

  19. Studies on the instrumentation of a beam-tube medium flux reactor

    International Nuclear Information System (INIS)

    Axmann, A.; Pollet, J.L.; Queudot, J.

    1979-01-01

    In the years 1977/78, the ad hoc commitee for medium-flux reactor development of the Federal Ministry for Research and Technology developed constructional concepts for a medium-flux reactor to be utilized by beam tube experiments. The HMI has elaborated contributions for discussions of the subject of instrumentation, in particular for experiments in solid state physics. These contributions are contained in the report. (orig./RW) [de

  20. Development of a radiology faculty appraisal instrument by using critical incident interviewing.

    Science.gov (United States)

    Collins, J; Albanese, M A; Thakor, S K; Propeck, P A; Scanlan, K A

    1997-12-01

    To develop a valid and reliable radiology faculty appraisal instrument based on scientific methods. Fifteen radiology residents participated in critical incident interviewing. During a 1-hour interview, a resident was asked to describe five incidents each of effective and ineffective faculty behavior. Two investigators independently listened to the tape-recorded interviews, and two different investigators sorted the incidents into broad categories. A faculty appraisal instrument was developed by listing similar incidents under broad categories. A five-point rating scale was applied to each item. Content validity was assessed by resident and faculty critique of the appraisal instrument. A total of 168 incidents of faculty behavior were generated. The frequency with which similar incidents were reported was recorded. The most common behaviors reported were related to staff expertise and teaching. Interjudge reliability was good, as determined by computing K indices of agreement (overall K = 0.59). There was good agreement regarding instrument content validity among residents but not among faculty. Residents supported the use of the new appraisal instrument, but further tests of validity and reliability and faculty acceptance of the instrument will determine its usefulness as a tool for monitoring faculty teaching performance and making decisions regarding faculty promotion.

  1. Self-folding micropatterned polymeric containers.

    Science.gov (United States)

    Azam, Anum; Laflin, Kate E; Jamal, Mustapha; Fernandes, Rohan; Gracias, David H

    2011-02-01

    We demonstrate self-folding of precisely patterned, optically transparent, all-polymeric containers and describe their utility in mammalian cell and microorganism encapsulation and culture. The polyhedral containers, with SU-8 faces and biodegradable polycaprolactone (PCL) hinges, spontaneously assembled on heating. Self-folding was driven by a minimization of surface area of the liquefying PCL hinges within lithographically patterned two-dimensional (2D) templates. The strategy allowed for the fabrication of containers with variable polyhedral shapes, sizes and precisely defined porosities in all three dimensions. We provide proof-of-concept for the use of these polymeric containers as encapsulants for beads, chemicals, mammalian cells and bacteria. We also compare accelerated hinge degradation rates in alkaline solutions of varying pH. These optically transparent containers resemble three-dimensional (3D) micro-Petri dishes and can be utilized to sustain, monitor and deliver living biological components.

  2. Toward automated assessment of health Web page quality using the DISCERN instrument.

    Science.gov (United States)

    Allam, Ahmed; Schulz, Peter J; Krauthammer, Michael

    2017-05-01

    As the Internet becomes the number one destination for obtaining health-related information, there is an increasing need to identify health Web pages that convey an accurate and current view of medical knowledge. In response, the research community has created multicriteria instruments for reliably assessing online medical information quality. One such instrument is DISCERN, which measures health Web page quality by assessing an array of features. In order to scale up use of the instrument, there is interest in automating the quality evaluation process by building machine learning (ML)-based DISCERN Web page classifiers. The paper addresses 2 key issues that are essential before constructing automated DISCERN classifiers: (1) generation of a robust DISCERN training corpus useful for training classification algorithms, and (2) assessment of the usefulness of the current DISCERN scoring schema as a metric for evaluating the performance of these algorithms. Using DISCERN, 272 Web pages discussing treatment options in breast cancer, arthritis, and depression were evaluated and rated by trained coders. First, different consensus models were compared to obtain a robust aggregated rating among the coders, suitable for a DISCERN ML training corpus. Second, a new DISCERN scoring criterion was proposed (features-based score) as an ML performance metric that is more reflective of the score distribution across different DISCERN quality criteria. First, we found that a probabilistic consensus model applied to the DISCERN instrument was robust against noise (random ratings) and superior to other approaches for building a training corpus. Second, we found that the established DISCERN scoring schema (overall score) is ill-suited to measure ML performance for automated classifiers. Use of a probabilistic consensus model is advantageous for building a training corpus for the DISCERN instrument, and use of a features-based score is an appropriate ML metric for automated DISCERN

  3. Problems in developing an instrument for the rapid assessment of personality status.

    Science.gov (United States)

    Van Horn, E; Manley, C; Leddy, D; Cicchetti, D; Tyrer, P

    2000-06-01

    To assess the validity of a quick assessment instrument (10 minutes) for assessing personality status, the Rapid Personality Assessment Schedule (PAS-R). The PAS-R was evaluated in psychotic patients recruited in one of the centres involved in a multicentre randomised controlled trial of intensive vs standard case management (the UK700 case management trial). Patients were assessed using both a full version of the PAS (PAS-I - ICD version) and the PAS-R. The weighted kappa statistic was used to gauge the (criterion-related) validity of the PAS-R using the PAS-I as the gold standard. Both measure code personality status using a four-point rating of severity in addition to recording individual categories of personality disorder. One hundred fifty-five (77%) of 201 patients recruited were assessed with both instruments. The weighted kappa statistic was 0.31, suggesting only moderate agreement between the PAS-I and PAS-R instruments under the four-point rating format, and 0.39 for the dichotomous personality disorder/no disorder separation. The sensitivity (64%) and specificity (82%) of the PAS-R in predicting PAS-I personality disorder were as satisfactory as for other screening instruments but still somewhat disappointing, and the PAS-R had an overall diagnostic accuracy of 78%. The PAS-R is a quick and rough method of detecting personality abnormality but is not a substitute for a fuller assessment.

  4. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.

    Science.gov (United States)

    Alapati, Satish B; Brantley, William A; Iijima, Masahiro; Clark, William A T; Kovarik, Libor; Buie, Caesar; Liu, Jie; Ben Johnson, William

    2009-11-01

    A novel thermomechanical processing procedure has been developed that yields a superelastic (SE) nickel-titanium (NiTi) wire (M-Wire) that laboratory testing shows has improved mechanical properties compared with conventional SE austenitic NiTi wires used for manufacture of rotary instruments. The objective of this study was to determine the origin of the improved mechanical properties. Specimens from 2 batches of M-Wire prepared under different processing conditions and from 1 batch of standard-processed SE wire for rotary instruments were examined by scanning transmission electron microscopy, temperature-modulated differential scanning calorimetry, micro-x-ray diffraction, and scanning electron microscopy with x-ray energy-dispersive spectrometric analyses. The processing for M-Wire yields a microstructure containing martensite, that the proportions of NiTi phases depend on processing conditions, and that the microstructure exhibits pronounced evidence of alloy strengthening. The presence of Ti(2)Ni precipitates in both microstructures indicates that M-Wire and the conventional SE wire for rotary instruments are titanium-rich.

  5. Design of a novel instrument for active neutron interrogation of artillery shells.

    Directory of Open Access Journals (Sweden)

    Camille Bélanger-Champagne

    Full Text Available The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  6. Instrument for bone mineral measurement using a microprocessor as the control and arithmetic element

    International Nuclear Information System (INIS)

    Alberi, J.L.; Hardy, W.H. II.

    1975-11-01

    A self-contained instrument for the determination of bone mineral content by photon absorptometry is described. A high-resolution detection system allows measurements to be made at up to 16 photon energies. Control and arithmetic functions are performed by a microprocessor. Analysis capability and limitations are discussed

  7. The 1997 HST Calibration Workshop with a New Generation of Instruments

    Science.gov (United States)

    Casertano, S. (Editor); Jedrzejewski, R. (Editor); Keyes, T. (Editor); Stevens, M. (Editor)

    1997-01-01

    The Second Servicing mission in early 1997 has brought major changes to the Hubble Space Telescope (HST). Two of the original instruments, Faint Object Spectrograph (FOS) and Goddard High Resolution Spectrograph (GHRS), were taken out, and replaced by completely new instruments, the Space Telescope Imaging Spectrograph (STIS) and the Near Infrared Camera Multi-Object Spectrograph (NICMOS). Two new types of detectors were installed, and for the first time, HST gained infrared capabilities. A new Fine Guidance Sensor (FGS) was installed, with an alignment mechanism that could improve substantially both guiding and astrometric capabilities. With all these changes come new challenges. The characterization of the new instruments has required a major effort, both by their respective Investigation Definition Teams and at the Space Telescope Science Institute. All necessary final calibrations for the retired spectrographs needed to be carried out, and their properties definitively characterized. At the same time, work has continued to improve our understanding of the instruments that have remained on board. The results of these activities were discussed in the 1997 HST (Hubble Space Telescope) Calibration Workshop. The main focus of the Workshop was to provide users with the tools and the understanding they need to use HST's instruments and archival data to the best of their possibilities. This book contains the written record of the Workshop. As such, it should provide a valuable tool to all interested in using existing HST data or in proposing for new observations.

  8. ATLAS Facility and Instrumentation Description Report

    International Nuclear Information System (INIS)

    Kang, Kyoung Ho; Moon, Sang Ki; Park, Hyun Sik

    2009-06-01

    A thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), has been constructed at KAERI (Korea Atomic Energy Research Institute). The ATLAS is a half-height and 1/288-volume scaled test facility with respect to the APR1400. The fluid system of the ATLAS consists of a primary system, a secondary system, a safety injection system, a break simulating system, a containment simulating system, and auxiliary systems. The primary system includes a reactor vessel, two hot legs, four cold legs, a pressurizer, four reactor coolant pumps, and two steam generators. The secondary system of the ATLAS is simplified to be of a circulating looptype. Most of the safety injection features of the APR1400 and the OPR1000 are incorporated into the safety injection system of the ATLAS. In the ATLAS test facility, about 1300 instrumentations are installed to precisely investigate the thermal-hydraulic behavior in simulation of the various test scenarios. This report describes the scaling methodology, the geometric data of the individual component, and the specification and the location of the instrumentations which are specific to the simulation of 50% DVI line break accident of the APR1400 for supporting the 50 th OECD/NEA International Standard Problem Exercise (ISP-50)

  9. Micro-dosemeter instrument (MIDN) for assessing risk in space

    International Nuclear Information System (INIS)

    Pisacane, V. L.; Dolecek, Q. E.; Malak, H.; Cucinotta, F. A.; Zaider, M.; Rosenfeld, A. B.; Rusek, A.; Sivertz, M.; Dicello, J. F.

    2011-01-01

    Radiation in space generally produces higher dose rates than that on the Earth's surface, and contributions from primary galactic and solar events increase with altitude within the magnetosphere. Presently, no personnel monitor is available to astronauts for real-time monitoring of dose, radiation quality and regulatory risk. This group is developing a prototypic instrument for use in an unknown, time-varying radiation field. This micro-dosemeter-dosemeter nucleon instrument is for use in a space-suit, spacecraft, remote rover and other applications. It provides absorbed dose, dose rate and dose equivalent in real time so that action can be taken to reduce exposure. Such a system has applications in health physics, anti-terrorism and radiation-hardening of electronics as well. The space system is described and results of ground-based studies are presented and compared with predictions of transport codes. An early prototype in 2007 was successfully launched, the only solid-state micro-dosemeter to have flown in space. Published by Oxford Univ. Press on behalf of the US Government 2011. (authors)

  10. Lateral Violence in Nursing Survey: Instrument Development and Validation

    Directory of Open Access Journals (Sweden)

    Lynne S. Nemeth

    2017-07-01

    Full Text Available An examination of the psychometric properties of the Lateral Violence in Nursing Survey (LVNS, an instrument previously developed to measure the perceived incidence and severity of lateral violence (LV in the nursing workplace, was carried out. Conceptual clustering and principal components analysis were used with survey responses from 663 registered nurses and ancillary nursing staff in a southeastern tertiary care medical center. Where appropriate, Cronbach’s alpha (α evaluated internal consistency. The prevalence/severity of lateral violence items constitute two distinct subscales (LV by self and others with Cronbach’s alpha of 0.74 and 0.86, respectively. The items asking about potential causes of LV are unidimensional and internally consistent (alpha = 0.77 but there is no conceptually coherent theme underlying the various causes. Respondents rating a potential LV cause as “major” scored higher on both prevalence/severity subscales than those rating it a “minor” cause or not a cause. Subsets of items on the LVNS are internally reliable, supporting construct validity. Revisions of the original LVNS instrument will improve its use in future work.

  11. Policy Instruments to Improve Energy Performance of Existing Owner Occupied Dwellings

    Directory of Open Access Journals (Sweden)

    Lorraine Colette Murphy

    2016-11-01

    Full Text Available The aim of this thesis is to add knowledge to the role and impact of policy instruments in meeting energy performance ambition in the existing owner occupied housing stock. The focus was instruments available in the Netherlands in 2011 and 2012. These instruments represented the ‘on the ground’ efforts to meet climate change targets and many continue to do so today in the same or slightly altered forms. At international level there is a recognized need to keep global temperatures within the range of 1.5 - 2°C above pre-industrial levels (Carrington, 2016. At European level, the 2020 package contains a series of binding legislation to help the EU meet its more immediate climate and energy targets. 2020 targets include 20% reduction in greenhouse gas emission, 20% of EU energy obtained from renewable sources and 20% improvement in energy efficiency. 2020 targets for the Netherlands are a 20% reduction in greenhouse gas emissions and a 14% increase in energy generation from renewable sources (Vringer et al., 2014. A raft of policies has been produced over the last number of decades from international to local level to orientate action towards targets. At European level the Energy Performance of Buildings Directive (EPBD drives efforts at reducing energy among one of the biggest players, the building sector. By requiring a mandatory certificate at the point of sale and rent of buildings and making regulatory demands on existing buildings the EPBD upped the ante of what could be expected from the building sector, but especially the existing dwelling stock. National governments have already been tackling existing dwellings for decades propelled by the energy crisis and later by climate change policy. Information campaigns, subsidies, energy taxes, energy loans and tailored advice are among the instruments that have been available to homeowners to carry out works on their dwellings to reduce energy consumption. In recent years, the pace of efforts

  12. Validation of low-cost ozone measurement instruments suitable for use in an air-quality monitoring network

    International Nuclear Information System (INIS)

    Williams, David E; Henshaw, Geoff S; Bart, Mark; Laing, Greer; Wagner, John; Naisbitt, Simon; Salmond, Jennifer A

    2013-01-01

    This paper presents a novel low-cost instrument that uses a sensor based on conductivity changes of heated tungstic oxide, which is capable of accurately measuring ambient concentrations of ozone. A combination of temperature steps and air flow-rate steps is used to continually reset and re-zero the sensor. A two-stage calibration procedure is presented, in which a nonlinear transformation converts sensor resistance to a signal linear in ozone concentration, then a linear correlation is used to align the calibration with a reference instrument. The required calibration functions specific for the sensor, and control system for air flow rate and sensor temperature, are housed with the sensor in a compact, simple-to-exchange assembly. The instrument can be operated on solar power and uses cell phone technology to enable monitoring in remote locations. Data from field trials are presented here to demonstrate that both the accuracy and the stability of the instrument over periods of months are within a few parts-per-billion by volume. We show that common failure modes can be detected through measurement of signals available from the instrument. The combination of long-term stability, self-diagnosis, and simple, inexpensive repair means that the cost of operation and calibration of the instruments is significantly reduced in comparison with traditional reference instrumentation. These instruments enable the economical construction and operation of ozone monitoring networks of accuracy, time resolution and spatial density sufficient to resolve the local gradients that are characteristic of urban air pollution. (paper)

  13. Instrument for measuring moisture in wood chips

    Energy Technology Data Exchange (ETDEWEB)

    Werme, L

    1980-06-01

    A method to determine the moisture content in wood chips, in batch and on-line, has been investigated. The method can be used for frozen and non frozen chips. Samples of wood chips are thawn and dryed with microwaves. During the drying the sample is weighed continously and the rate of drying is measured. The sample is dried t 10 percent moisture content. The result is extrapolated to the drying rate zero. The acccuracy at the method is 1.6 to 1.7 percent for both frozen and non frozen chips. The accuracy of the method is considered acceptable, but sofisticated sampling equipment is necessary. This makes the method too complex to make the instrument marketable.

  14. Impact of the Atlantic Multidecadal Oscillation (AMO) on deriving anthropogenic warming rates from the instrumental temperature record

    NARCIS (Netherlands)

    van der Werf, G.R.; Dolman, A.J.

    2014-01-01

    The instrumental surface air temperature record has been used in several statistical studies to assess the relative role of natural and anthropogenic drivers of climate change. The results of those studies varied considerably, with anthropogenic temperature trends over the past 25-30 years suggested

  15. Evaluation of an air drilling cuttings containment system

    Energy Technology Data Exchange (ETDEWEB)

    Westmoreland, J.

    1994-04-01

    Drilling at hazardous waste sites for environmental remediation or monitoring requires containment of all drilling fluids and cuttings to protect personnel and the environment. At many sites, air drilling techniques have advantages over other drilling methods, requiring effective filtering and containment of the return air/cuttings stream. A study of. current containment methods indicated improvements could be made in the filtering of radionuclides and volatile organic compounds, and in equipment like alarms, instrumentation or pressure safety features. Sandia National Laboratories, Dept. 61 11 Environmental Drilling Projects Group, initiated this work to address these concerns. A look at the industry showed that asbestos abatement equipment could be adapted for containment and filtration of air drilling returns. An industry manufacturer was selected to build a prototype machine. The machine was leased and put through a six-month testing and evaluation period at Sandia National Laboratories. Various materials were vacuumed and filtered with the machine during this time. In addition, it was used in an actual air drive drilling operation. Results of these tests indicate that the vacuum/filter unit will meet or exceed our drilling requirements. This vacuum/filter unit could be employed at a hazardous waste site or any site where drilling operations require cuttings and air containment.

  16. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  17. Nonparametric instrumental regression with non-convex constraints

    International Nuclear Information System (INIS)

    Grasmair, M; Scherzer, O; Vanhems, A

    2013-01-01

    This paper considers the nonparametric regression model with an additive error that is dependent on the explanatory variables. As is common in empirical studies in epidemiology and economics, it also supposes that valid instrumental variables are observed. A classical example in microeconomics considers the consumer demand function as a function of the price of goods and the income, both variables often considered as endogenous. In this framework, the economic theory also imposes shape restrictions on the demand function, such as integrability conditions. Motivated by this illustration in microeconomics, we study an estimator of a nonparametric constrained regression function using instrumental variables by means of Tikhonov regularization. We derive rates of convergence for the regularized model both in a deterministic and stochastic setting under the assumption that the true regression function satisfies a projected source condition including, because of the non-convexity of the imposed constraints, an additional smallness condition. (paper)

  18. Nonparametric instrumental regression with non-convex constraints

    Science.gov (United States)

    Grasmair, M.; Scherzer, O.; Vanhems, A.

    2013-03-01

    This paper considers the nonparametric regression model with an additive error that is dependent on the explanatory variables. As is common in empirical studies in epidemiology and economics, it also supposes that valid instrumental variables are observed. A classical example in microeconomics considers the consumer demand function as a function of the price of goods and the income, both variables often considered as endogenous. In this framework, the economic theory also imposes shape restrictions on the demand function, such as integrability conditions. Motivated by this illustration in microeconomics, we study an estimator of a nonparametric constrained regression function using instrumental variables by means of Tikhonov regularization. We derive rates of convergence for the regularized model both in a deterministic and stochastic setting under the assumption that the true regression function satisfies a projected source condition including, because of the non-convexity of the imposed constraints, an additional smallness condition.

  19. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  20. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).