WorldWideScience

Sample records for rapidly applied transient

  1. Transient burnout under rapid flow reduction condition

    International Nuclear Information System (INIS)

    Iwamura, Takamichi

    1987-01-01

    Burnout characteristics were experimentally studied using uniformly heated tube and annular test sections under rapid flow reduction conditions. Observations indicated that the onset of burnout under a flow reduction transient is caused by the dryout of a liquid film on the heated surface. The decrease in burnout mass velocity at the channel inlet with increasing flow reduction rate is attributed to the fact that the vapor flow rate continues to increase and sustain the liquid film flow after the inlet flow rate reaches the steady-state burnout flow rate. This is because the movement of the boiling boundary cannot keep up with the rapid reduction of inlet flow rate. A burnout model for the local condition could be applied to the burnout phenomena with the flow reduction under pressures of 0.5 ∼ 3.9 MPa and flow reduction rates of 0.6 ∼ 35 %/s. Based on this model, a method to predict the burnout time under a flow reduction condition was presented. The calculated burnout times agreed well with experimental results obtained by some investigators. (author)

  2. Rapidly Evolving Transients in the Dark Energy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pursiainen, M.; et al.

    2018-03-13

    We present the results of a search for rapidly evolving transients in the Dark Energy Survey Supernova Programme. These events are characterized by fast light curve evolution (rise to peak in $\\lesssim 10$ d and exponential decline in $\\lesssim30$ d after peak). We discovered 72 events, including 37 transients with a spectroscopic redshift from host galaxy spectral features. The 37 events increase the total number of rapid optical transients by more than factor of two. They are found at a wide range of redshifts ($0.05M_\\mathrm{g}>-22.25$). The multiband photometry is well fit by a blackbody up to few weeks after peak. The events appear to be hot ($T\\approx10000-30000$ K) and large ($R\\approx 10^{14}-2\\cdot10^{15}$ cm) at peak, and generally expand and cool in time, though some events show evidence for a receding photosphere with roughly constant temperature. Spectra taken around peak are dominated by a blue featureless continuum consistent with hot, optically thick ejecta. We compare our events with a previously suggested physical scenario involving shock breakout in an optically thick wind surrounding a core-collapse supernova (CCSNe), we conclude that current models for such a scenario might need an additional power source to describe the exponential decline. We find these transients tend to favor star-forming host galaxies, which could be consistent with a core-collapse origin. However, more detailed modeling of the light curves is necessary to determine their physical origin.

  3. Physical modelling of a rapid boron dilution transient

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G.; Hemstroem, B.; Karlsson, R. [Vattenfall Utveckling AB, Aelvkarleby (Sweden); Jacobson, S. [Vattenfall AB, Ringhals, Vaeroebacka (Sweden)

    1995-09-01

    The analysis of boron dilution accidents in pressurised water reactors has traditionally assumed that mixing is instantaneous and complete everywhere, eliminating in this way the possibility of concentration inhomogeneities. Situations can nevertheless arise where a volume of coolant with a low boron concentration may eventually enter the core and generate a severe reactivity transient. The work presented in this paper deals with a category of Rapid Boron Dilution Events characterised by a rapid start of a Reactor Coolant Pump (RCP) with a plug of relatively unborated water present in the RCS pipe. Model tests have been made at Vattenfall Utveckling AB in a simplified 1:5 scale model of a Westinghouse PWR. Conductivity measurements are used to determine dimensionless boron concentration. The main purpose of this experimental work is to define an experimental benchmark against which a mathematical model can be tested. The final goal is to be able to numerically predict Boron Dilution Transients. This work has been performed as a part of a Co-operative Agreement with Electricite` de France (EDF).

  4. RAPIDLY RISING TRANSIENTS IN THE SUPERNOVA—SUPERLUMINOUS SUPERNOVA GAP

    Energy Technology Data Exchange (ETDEWEB)

    Arcavi, Iair; Howell, D. Andrew [Las Cumbres Observatory Global Telescope, 6740 Cortona Dr., Suite 102, Goleta, CA 93111 (United States); Wolf, William M. [Department of Physics, University of California, Santa Barbara, CA 93106 (United States); Bildsten, Lars; McCully, Curtis; Valenti, Stefano [Kavli Institute for Theoretical Physics, University of California, Santa Barbara, CA 93106 (United States); Leloudas, Giorgos; Gal-Yam, Avishay; Katz, Boaz [Department of Particle Physics and Astrophysics, The Weizmann Institute of Science, Rehovot, 76100 (Israel); Hardin, Delphine; Astier, Pierre; Balland, Cristophe [LPNHE, CNRS-IN2P3 and University of Paris VI and VII, F-75005 Paris (France); Prajs, Szymon; Sullivan, Mark [School of Physics and Astronomy, University of Southampton, Southampton, SO17 1BJ (United Kingdom); Perley, Daniel A. [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen (Denmark); Svirski, Gilad [Racah Institute for Physics, The Hebrew University, Jerusalem 91904 (Israel); Cenko, S. Bradley [Astrophysics Science Division, NASA Goddard Space Flight Center, Mail Code 661, Greenbelt, MD 20771 (United States); Lidman, Chris [Australian Astronomical Observatory, P.O. Box 915, North Ryde, NSW 1670 (Australia); Carlberg, Ray G. [Department of Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H8 (Canada); Conley, Alex, E-mail: iarcavi@lcogt.net [Center for Astrophysics and Space Astronomy, University of Colorado, 389 UCB, Boulder, CO 80309-389 (United States); and others

    2016-03-01

    We present observations of four rapidly rising (t{sub rise} ≈ 10 days) transients with peak luminosities between those of supernovae (SNe) and superluminous SNe (M{sub peak} ≈ −20)—one discovered and followed by the Palomar Transient Factory (PTF) and three by the Supernova Legacy Survey. The light curves resemble those of SN 2011kl, recently shown to be associated with an ultra-long-duration gamma-ray burst (GRB), though no GRB was seen to accompany our SNe. The rapid rise to a luminous peak places these events in a unique part of SN phase space, challenging standard SN emission mechanisms. Spectra of the PTF event formally classify it as an SN II due to broad Hα emission, but an unusual absorption feature, which can be interpreted as either high velocity Hα (though deeper than in previously known cases) or Si ii (as seen in SNe Ia), is also observed. We find that existing models of white dwarf detonations, CSM interaction, shock breakout in a wind (or steeper CSM), and magnetar spin down cannot readily explain the observations. We consider the possibility that a “Type 1.5 SN” scenario could be the origin of our events. More detailed models for these kinds of transients and more constraining observations of future such events should help to better determine their nature.

  5. 40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What transient duty cycles apply for... Procedures § 1048.510 What transient duty cycles apply for laboratory testing? (a) Starting with the 2007 model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in...

  6. Rapid thermal transient in a reactor coolant channel

    International Nuclear Information System (INIS)

    Cherubini, A.

    1986-01-01

    This report deals with the problem of one-dimensional thermo-fluid-dynamics in a reactor coolant channel, with the aim of determining the evolution in time of the coolant (H*L2O), in one-and/or two-phase regimes, subjected to a great and rapid increase in heat flux (accident conditions). To this aim, the following are set out: a) the physical model used; b) the equations inherent in the above model; c) the numerical methods employed to solve them by means of a computer programme called CABO (CAnale BOllente). Next a typical problem of rapid thermal transient resolved by CABO is reported. The results obtained, expressed in form of graphs, are fully discussed. Finally comments on possible developments of CABO follow

  7. Applied hydraulic transients

    CERN Document Server

    Chaudhry, M Hanif

    2014-01-01

    This book covers hydraulic transients in a comprehensive and systematic manner from introduction to advanced level and presents various methods of analysis for computer solution. The field of application of the book is very broad and diverse and covers areas such as hydroelectric projects, pumped storage schemes, water-supply systems, cooling-water systems, oil pipelines and industrial piping systems. Strong emphasis is given to practical applications, including several case studies, problems of applied nature, and design criteria. This will help design engineers and introduce students to real-life projects. This book also: ·         Presents modern methods of analysis suitable for computer analysis, such as the method of characteristics, explicit and implicit finite-difference methods and matrix methods ·         Includes case studies of actual projects ·         Provides extensive and complete treatment of governed hydraulic turbines ·         Presents design charts, desi...

  8. SPRAT: Spectrograph for the Rapid Acquisition of Transients

    Science.gov (United States)

    Piascik, A. S.; Steele, Iain A.; Bates, Stuart D.; Mottram, Christopher J.; Smith, R. J.; Barnsley, R. M.; Bolton, B.

    2014-07-01

    We describe the development of a low cost, low resolution (R ~ 350), high throughput, long slit spectrograph covering visible (4000-8000) wavelengths. The spectrograph has been developed for fully robotic operation with the Liverpool Telescope (La Palma). The primary aim is to provide rapid spectral classification of faint (V ˜ 20) transient objects detected by projects such as Gaia, iPTF (intermediate Palomar Transient Factory), LOFAR, and a variety of high energy satellites. The design employs a volume phase holographic (VPH) transmission grating as the dispersive element combined with a prism pair (grism) in a linear optical path. One of two peak spectral sensitivities are selectable by rotating the grism. The VPH and prism combination and entrance slit are deployable, and when removed from the beam allow the collimator/camera pair to re-image the target field onto the detector. This mode of operation provides automatic acquisition of the target onto the slit prior to spectrographic observation through World Coordinate System fitting. The selection and characterisation of optical components to maximise photon throughput is described together with performance predictions.

  9. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei-Jiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang, Chun-Lu [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed. (author)

  10. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weijiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang Chunlu, E-mail: chunlu.zhang@carrier.utc.co [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed.

  11. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    International Nuclear Information System (INIS)

    Zhang Weijiang; Zhang Chunlu

    2011-01-01

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed.

  12. Hydraulic Transients Caused by Air Expulsion During Rapid Filling of Undulating Pipelines

    Directory of Open Access Journals (Sweden)

    Ciro Apollonio

    2016-01-01

    Full Text Available One of the main issues arising during the rapid filling of a pipeline is the pressure transient which originates after the entrapped air has been expelled at the air release valve. Because of the difference in density between water and air, a pressure transient originates at the impact of the water column. Many authors have analyzed the problem, both from the theoretical and the experimental standpoint. Nevertheless, mainly vertical or horizontal pipelines have been analyzed, whereas in real field applications, the pipe profile is a sequence of ascending and descending pipes, with air release/vacuum valves at high points. To overcome lack of knowledge regarding this latter case, laboratory experiments were carried out to simulate the filling of an undulating pipeline, initially empty at atmospheric pressure. The pipe profile has a high point where an orifice is installed for air venting, so as to simulate the air release valve at intermediate high point of a supply pipeline. In the experiments, the diameter of the orifice and the opening degree of both upstream and downstream valves were varied, in order to analyze their effect on the pressure transient. The experiments were also carried out with a longer descending pipe, in order to assess the effects on the pressure surge of the air volume downstream of the orifice.

  13. Rapid transient expression of human granulocyte-macrophage colony-stimulating factor in two industrial cultivars of tobacco (Nicotiana tabacum L. by agroinfiltration

    Directory of Open Access Journals (Sweden)

    Lea Vojta

    2015-09-01

    Full Text Available We report the production of hGM-CSF cytokine in leaves of industrial tobacco cultivars DH-17 and DH-27 by using Agrobacterium-mediated transient expression. We prove the concept that very high biomass industrial tobacco plants are suitable platforms for rapid, low cost production of foreign proteins. Successful transient expression of the GM-CSF was achieved in less than three months, opening the possibility for future applications of this approach in rapid response production of various proteins of non-plant origin in industrial tobacco.

  14. Uncertainty and sensitivity analysis applied to coupled code calculations for a VVER plant transient

    International Nuclear Information System (INIS)

    Langenbuch, S.; Krzykacz-Hausmann, B.; Schmidt, K. D.

    2004-01-01

    The development of coupled codes, combining thermal-hydraulic system codes and 3D neutron kinetics, is an important step to perform best-estimate plant transient calculations. It is generally agreed that the application of best-estimate methods should be supplemented by an uncertainty and sensitivity analysis to quantify the uncertainty of the results. The paper presents results from the application of the GRS uncertainty and sensitivity method for a VVER-440 plant transient, which was already studied earlier for the validation of coupled codes. For this application, the main steps of the uncertainty method are described. Typical results of the method applied to the analysis of the plant transient by several working groups using different coupled codes are presented and discussed The results demonstrate the capability of an uncertainty and sensitivity analysis. (authors)

  15. Rapid High-Level Production of Functional HIV Broadly Neutralizing Monoclonal Antibodies in Transient Plant Expression Systems

    Science.gov (United States)

    Rosenberg, Yvonne; Sack, Markus; Montefiori, David; Forthal, Donald; Mao, Lingjun; -Abanto, Segundo Hernandez; Urban, Lori; Landucci, Gary; Fischer, Rainer; Jiang, Xiaoming

    2013-01-01

    Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs) has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT) of simian/human immunodeficiency virus (SHIV) in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01) or a single chain antibody construct (m9), for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production. PMID:23533588

  16. Rapid high-level production of functional HIV broadly neutralizing monoclonal antibodies in transient plant expression systems.

    Directory of Open Access Journals (Sweden)

    Yvonne Rosenberg

    Full Text Available Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT of simian/human immunodeficiency virus (SHIV in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01 or a single chain antibody construct (m9, for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production.

  17. Diagnosis of class using swarm intelligence applied to problem of identification of nuclear transient

    Energy Technology Data Exchange (ETDEWEB)

    Villas Boas Junior, Manoel; Strauss, Edilberto, E-mail: junior@lmp.ufrj.b [Instituto Federal de Educacao, Ciencia e Tecnologia do Ceara/ Universidade do Estado do Ceara, Itaperi, CE (Brazil). Mestrado Integrado em Computacao Aplicada; Nicolau, Andressa dos Santos; Schirru, Roberto, E-mail: andressa@lmp.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Mello, Flavio Luis de [Universidade Federal do Rio de Janeiro (POLI/UFRJ), RJ (Brazil). Escola Politecnica. Dept. de Engenharia Eletronica e Computacao

    2011-07-01

    This article presents a computational model of the diagnostic system of transient. The model makes use of segmentation techniques applied to support decision making, based on identification of classes and optimized by Particle Swarm Optimization algorithm (PSO). The method proposed aims to classify an anomalous event in the signatures of three classes of the design basis transients postulated for the Angra 2 nuclear plant, where the PSO algorithm is used as a method of separation of classes, being responsible for finding the best centroid prototype vector of each accident/transient, ie equivalent to Voronoi vector that maximizes the number of correct classifications. To make the calculation of similarity between the set of the variables anomalous event in a given time t, and the prototype vector of variables of accident/transients, the metrics of Manhattan, Euclidean and Minkowski were used. The results obtained by the method proposed were compatible with others methods reported in the literature, allowing a solution that approximates the ideal solution, ie the Voronoi vectors. (author)

  18. Diagnosis of class using swarm intelligence applied to problem of identification of nuclear transient

    International Nuclear Information System (INIS)

    Villas Boas Junior, Manoel; Strauss, Edilberto; Nicolau, Andressa dos Santos; Schirru, Roberto; Mello, Flavio Luis de

    2011-01-01

    This article presents a computational model of the diagnostic system of transient. The model makes use of segmentation techniques applied to support decision making, based on identification of classes and optimized by Particle Swarm Optimization algorithm (PSO). The method proposed aims to classify an anomalous event in the signatures of three classes of the design basis transients postulated for the Angra 2 nuclear plant, where the PSO algorithm is used as a method of separation of classes, being responsible for finding the best centroid prototype vector of each accident/transient, ie equivalent to Voronoi vector that maximizes the number of correct classifications. To make the calculation of similarity between the set of the variables anomalous event in a given time t, and the prototype vector of variables of accident/transients, the metrics of Manhattan, Euclidean and Minkowski were used. The results obtained by the method proposed were compatible with others methods reported in the literature, allowing a solution that approximates the ideal solution, ie the Voronoi vectors. (author)

  19. Characterization of transient discharges under atmospheric-pressure conditions applying nitrogen photoemission and current measurements

    International Nuclear Information System (INIS)

    Keller, Sandra; Rajasekaran, Priyadarshini; Bibinov, Nikita; Awakowicz, Peter

    2012-01-01

    The plasma parameters such as electron distribution function and electron density of three atmospheric-pressure transient discharges namely filamentary and homogeneous dielectric barrier discharges in air, and the spark discharge of an argon plasma coagulation (APC) system are determined. A combination of numerical simulation as well as diagnostic methods including current measurement and optical emission spectroscopy (OES) based on nitrogen emissions is used. The applied methods supplement each other and resolve problems, which arise when these methods are used individually. Nitrogen is used as a sensor gas and is admixed in low amount to argon for characterizing the APC discharge. Both direct and stepwise electron-impact excitation of nitrogen emissions are included in the plasma-chemical model applied for characterization of these transient discharges using OES where ambiguity arises in the determination of plasma parameters under specific discharge conditions. It is shown that the measured current solves this problem by providing additional information useful for the determination of discharge-specific plasma parameters. (paper)

  20. Transient heat conduction in a pebble fuel applying fractional model

    International Nuclear Information System (INIS)

    Gomez A, R.; Espinosa P, G.

    2009-10-01

    In this paper we presents the equation of thermal diffusion of temporary-fractional order in the one-dimensional space in spherical coordinates, with the objective to analyze the heat transference between the fuel and coolant in a fuel element of a Pebble Bed Modular Reactor. The pebble fuel is the heterogeneous system made by microsphere constitutes by U O, pyrolytic carbon and silicon carbide mixed with graphite. To describe the heat transfer phenomena in the pebble fuel we applied a constitutive law fractional (Non-Fourier) in order to analyze the behaviour transient of the temperature distribution in the pebble fuel with anomalous thermal diffusion effects a numerical model is developed. (Author)

  1. Velocity dependence of transient hyperfine field at Pt ions rapidly recoiling through magnetized Fe

    International Nuclear Information System (INIS)

    Stuchbery, A.E.; Ryan, C.G.; Bolotin, H.H.

    1981-01-01

    The velocity-dependence of the transient hyperfine magnetic field acting at nuclei of 196 Pt ions rapidly recoiling through thin magnetized Fe was investigated at a number of recoil velocities. The state of interest (2 1 + ) was populated by Coulomb excitation using beams of 80- and 120-MeV 32 S and 150- and 220-MeV 58 Ni ions. The 2 1 + →0 1 + γ-ray angular distribution precession measurements were carried out in coincidence with backscattered projectiles. From these results, the strength of the transient field acting on Pt ions recoiling through magnetized Fe with average velocities in the extended range 2.14<=v/vsub(o)<=4.82 (vsub(o) = c/137) was found to be consistent with a linear velocity dependence and to be incompatible with the specific vsup(0.45+-0.18) dependence which has been previously reported to account well for all ions in the mass range from oxygen through samarium. This seemingly singular behaviour for Pt and other ions in the Pt mass vicinity is discussed

  2. Simulation of heat pipe rapid transient performance using a multi-nodal implicit finite difference scheme

    International Nuclear Information System (INIS)

    Peery, J.S.; Best, F.R.

    1987-01-01

    A model to simulate heat pipe rapid transients has been developed. This model uses a one-dimensional development of the continuity and momentum equations to solve for the velocity and pressure distributions in both the liquid and vapor regions. A two-dimensional development of the energy equation is used to determine the temperature distributions in the liquid and vapor regions, as well as in the walls of the heat pipe. The vapor and liquid regions are coupled through mass and energy transfer due to evaporation and condensation. The model used for this phenomenon is based on the physical conditions of the vapor and liquid for a given node. However, this model for evaporation and condensation not only causes the energy equation to be nonlinear but also constrains the time step to 10 -4 seconds for convergence to be reached. The model has been run for small transients up to 2 seconds to produce temperature distributions and demonstrate the convergence difficulties associated with the evaporation/condensation model used

  3. Modeling and Controlling Flow Transient in Pipeline Systems: Applied for Reservoir and Pump Systems Combined with Simple Surge Tank

    Directory of Open Access Journals (Sweden)

    Itissam ABUIZIAH

    2014-03-01

    Full Text Available When transient conditions (water hammer exist, the life expectancy of the system can be adversely impacted, resulting in pump and valve failures and catastrophic pipe rupture. Hence, transient control has become an essential requirement for ensuring safe operation of water pipeline systems. To protect the pipeline systems from transient effects, an accurate analysis and suitable protection devices should be used. This paper presents the problem of modeling and simulation of transient phenomena in hydraulic systems based on the characteristics method. Also, it provides the influence of using the protection devices to control the adverse effects due to excessive and low pressure occuring in the transient. We applied this model for two main pipeline systems: Valve and pump combined with a simple surge tank connected to reservoir. The results obtained by using this model indicate that the model is an efficient tool for water hammer analysis. Moreover, using a simple surge tank reduces the unfavorable effects of transients by reducing pressure fluctuations.

  4. MHD aspects of coronal transients

    International Nuclear Information System (INIS)

    Anzer, U.

    1979-10-01

    If one defines coronal transients as events which occur in the solar corona on rapid time scales (< approx. several hours) then one would have to include a large variety of solar phenomena: flares, sprays, erupting prominences, X-ray transients, white light transients, etc. Here we shall focus our attention on the latter two phenomena. (orig.) 891 WL/orig. 892 RDG

  5. Evaluating transient performance of servo mechanisms by analysing stator current of PMSM

    Science.gov (United States)

    Zhang, Qing; Tan, Luyao; Xu, Guanghua

    2018-02-01

    Smooth running and rapid response are the desired performance goals for the transient motions of servo mechanisms. Because of the uncertain and unobservable transient behaviour of servo mechanisms, it is difficult to evaluate their transient performance. Under the effects of electromechanical coupling, the stator current signals of a permanent-magnet synchronous motor (PMSM) potentially contain the performance information regarding servo mechanisms in use. In this paper, a novel method based on analysing the stator current of the PMSM is proposed for quantifying the transient performance. First, a vector control model is constructed to simulate the stator current behaviour in the transient processes of consecutive speed changes, consecutive load changes, and intermittent start-stops. It is discovered that the amplitude and frequency of the stator current are modulated by the transient load torque and motor speed, respectively. The stator currents under different performance conditions are also simulated and compared. Then, the stator current is processed using a local means decomposition (LMD) algorithm to extract the instantaneous amplitude and instantaneous frequency. The sample entropy of the instantaneous amplitude, which reflects the complexity of the load torque variation, is calculated as a performance indicator of smooth running. The peak-to-peak value of the instantaneous frequency, which defines the range of the motor speed variation, is set as a performance indicator of rapid response. The proposed method is applied to both simulated data in an intermittent start-stops process and experimental data measured for a batch of servo turrets for turning lathes. The results show that the performance evaluations agree with the actual performance.

  6. Influence of the applied voltage on the Rapid Chloride Migration (RCM) test

    NARCIS (Netherlands)

    Spiesz, P.R.; Brouwers, H.J.H.

    2012-01-01

    This study addresses the influence of the applied voltage (electrical field) on the value of the chloride migration coefficient, as determined with the Rapid Chloride Migration (RCM) test, and on other properties of cement based mortars. It is shown that in the investigated ranges of applied

  7. Transient flows in rectangular MHD ducts under the influence of suddenly changing applied magnetic fields

    International Nuclear Information System (INIS)

    Kobayashi, Junichi

    1979-01-01

    The study on the transient flow characteristics in MHD ducts under orthogonal magnetic field is divided into handling two problems: the problem of changing pressure gradient in a uniform orthogonal magnetic field and the problem in which the orthogonal magnetic field itself changes with time. The former has been investigated by many persons, but the latter has not been investigated so often as the former because of its difficulty of handling. In addition, if it is intended to grasp properly the transient flow characteristics in actual MHD ducts, it will be also important that the effects of the electric conductivity of side walls and aspect ratio are clarified. In other words, this paper deals with the problem in which a uniform orthogonal magnetic field is suddenly applied in such manner as Heaviside's step function to or removed from the conductive fluids flowing in sufficiently long rectangular MHD ducts. First, the MHD fundamental equations are described, then they are normalized to give boundary conditions and initial conditions. Next, the transient flow and the derived magnetic field characteristics are numerically analyzed by the difference calculus, and thus the effects of conductor, insulated wall, aspect ratio, Hartmann number, magnetic Prandtl number and others on the above characteristics are clarified. (Wakatsuki, Y.)

  8. Transient magnetoviscosity of dilute ferrofluids

    International Nuclear Information System (INIS)

    Soto-Aquino, Denisse; Rinaldi, Carlos

    2011-01-01

    The magnetic field induced change in the viscosity of a ferrofluid, commonly known as the magnetoviscous effect and parameterized through the magnetoviscosity, is one of the most interesting and practically relevant aspects of ferrofluid phenomena. Although the steady state behavior of ferrofluids under conditions of applied constant magnetic fields has received considerable attention, comparatively little attention has been given to the transient response of the magnetoviscosity to changes in the applied magnetic field or rate of shear deformation. Such transient response can provide further insight into the dynamics of ferrofluids and find practical application in the design of devices that take advantage of the magnetoviscous effect and inevitably must deal with changes in the applied magnetic field and deformation. In this contribution Brownian dynamics simulations and a simple model based on the ferrohydrodynamics equations are applied to explore the dependence of the transient magnetoviscosity for two cases: (I) a ferrofluid in a constant shear flow wherein the magnetic field is suddenly turned on, and (II) a ferrofluid in a constant magnetic field wherein the shear flow is suddenly started. Both simulations and analysis show that the transient approach to a steady state magnetoviscosity can be either monotonic or oscillatory depending on the relative magnitudes of the applied magnetic field and shear rate. - Research Highlights: →Rotational Brownian dynamics simulations were used to study the transient behavior of the magnetoviscosity of ferrofluids. →Damped and oscillatory approach to steady state magnetoviscosity was observed for step changes in shear rate and magnetic field. →A model based on the ferrohydrodynamics equations qualitatively captured the damped and oscillatory features of the transient response →The transient behavior is due to the interplay of hydrodynamic, magnetic, and Brownian torques on the suspended particles.

  9. Validation of the Applied Biosystems RapidFinder Shiga Toxin-Producing E. coli (STEC) Detection Workflow.

    Science.gov (United States)

    Cloke, Jonathan; Matheny, Sharon; Swimley, Michelle; Tebbs, Robert; Burrell, Angelia; Flannery, Jonathan; Bastin, Benjamin; Bird, Patrick; Benzinger, M Joseph; Crowley, Erin; Agin, James; Goins, David; Salfinger, Yvonne; Brodsky, Michael; Fernandez, Maria Cristina

    2016-11-01

    The Applied Biosystems™ RapidFinder™ STEC Detection Workflow (Thermo Fisher Scientific) is a complete protocol for the rapid qualitative detection of Escherichia coli (E. coli) O157:H7 and the "Big 6" non-O157 Shiga-like toxin-producing E. coli (STEC) serotypes (defined as serogroups: O26, O45, O103, O111, O121, and O145). The RapidFinder STEC Detection Workflow makes use of either the automated preparation of PCR-ready DNA using the Applied Biosystems PrepSEQ™ Nucleic Acid Extraction Kit in conjunction with the Applied Biosystems MagMAX™ Express 96-well magnetic particle processor or the Applied Biosystems PrepSEQ Rapid Spin kit for manual preparation of PCR-ready DNA. Two separate assays comprise the RapidFinder STEC Detection Workflow, the Applied Biosystems RapidFinder STEC Screening Assay and the Applied Biosystems RapidFinder STEC Confirmation Assay. The RapidFinder STEC Screening Assay includes primers and probes to detect the presence of stx1 (Shiga toxin 1), stx2 (Shiga toxin 2), eae (intimin), and E. coli O157 gene targets. The RapidFinder STEC Confirmation Assay includes primers and probes for the "Big 6" non-O157 STEC and E. coli O157:H7. The use of these two assays in tandem allows a user to detect accurately the presence of the "Big 6" STECs and E. coli O157:H7. The performance of the RapidFinder STEC Detection Workflow was evaluated in a method comparison study, in inclusivity and exclusivity studies, and in a robustness evaluation. The assays were compared to the U.S. Department of Agriculture (USDA), Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook (MLG) 5.09: Detection, Isolation and Identification of Escherichia coli O157:H7 from Meat Products and Carcass and Environmental Sponges for raw ground beef (73% lean) and USDA/FSIS-MLG 5B.05: Detection, Isolation and Identification of Escherichia coli non-O157:H7 from Meat Products and Carcass and Environmental Sponges for raw beef trim. No statistically significant

  10. Thermally induced dispersion mechanisms for aluminum-based plate-type fuels under rapid transient energy deposition

    International Nuclear Information System (INIS)

    Georgevich, V.; Taleyarkham, R.P.; Navarro-Valenti, S.; Kim, S.H.

    1995-01-01

    A thermally induced dispersion model was developed to analyze for dispersive potential and determine onset of fuel plate dispersion for Al-based research and test reactor fuels. Effect of rapid energy deposition in a fuel plate was simulated. Several data types for Al-based fuels tested in the Nuclear Safety Research Reactor in Japan and in the Transient Reactor Test in Idaho were reviewed. Analyses of experiments show that onset of fuel dispersion is linked to a sharp rise in predicted strain rate, which futher coincides with onset of Al vaporization. Analysis also shows that Al oxidation and exothermal chemical reaction between the fuel and Al can significantly affect the energy deposition characteristics, and therefore dispersion onset connected with Al vaporization, and affect onset of vaporization

  11. Protoplast isolation, transient transformation of leaf mesophyll protoplasts and improved Agrobacterium-mediated leaf disc infiltration of Phaseolus vulgaris: tools for rapid gene expression analysis.

    Science.gov (United States)

    Nanjareddy, Kalpana; Arthikala, Manoj-Kumar; Blanco, Lourdes; Arellano, Elizabeth S; Lara, Miguel

    2016-06-24

    Phaseolus vulgaris is one of the most extensively studied model legumes in the world. The P. vulgaris genome sequence is available; therefore, the need for an efficient and rapid transformation system is more imperative than ever. The functional characterization of P. vulgaris genes is impeded chiefly due to the non-amenable nature of Phaseolus sp. to stable genetic transformation. Transient transformation systems are convenient and versatile alternatives for rapid gene functional characterization studies. Hence, the present work focuses on standardizing methodologies for protoplast isolation from multiple tissues and transient transformation protocols for rapid gene expression analysis in the recalcitrant grain legume P. vulgaris. Herein, we provide methodologies for the high-throughput isolation of leaf mesophyll-, flower petal-, hypocotyl-, root- and nodule-derived protoplasts from P. vulgaris. The highly efficient polyethylene glycol-mannitol magnesium (PEG-MMG)-mediated transformation of leaf mesophyll protoplasts was optimized using a GUS reporter gene. We used the P. vulgaris SNF1-related protein kinase 1 (PvSnRK1) gene as proof of concept to demonstrate rapid gene functional analysis. An RT-qPCR analysis of protoplasts that had been transformed with PvSnRK1-RNAi and PvSnRK1-OE vectors showed the significant downregulation and ectopic constitutive expression (overexpression), respectively, of the PvSnRK1 transcript. We also demonstrated an improved transient transformation approach, sonication-assisted Agrobacterium-mediated transformation (SAAT), for the leaf disc infiltration of P. vulgaris. Interestingly, this method resulted in a 90 % transformation efficiency and transformed 60-85 % of the cells in a given area of the leaf surface. The constitutive expression of YFP further confirmed the amenability of the system to gene functional characterization studies. We present simple and efficient methodologies for protoplast isolation from multiple P

  12. Thermal transient analysis applied to horizontal wells

    Energy Technology Data Exchange (ETDEWEB)

    Duong, A.N. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[ConocoPhillips Canada Resources Corp., Calgary, AB (Canada)

    2008-10-15

    Steam assisted gravity drainage (SAGD) is a thermal recovery process used to recover bitumen and heavy oil. This paper presented a newly developed model to estimate cooling time and formation thermal diffusivity by using a thermal transient analysis along the horizontal wellbore under a steam heating process. This radial conduction heating model provides information on the heat influx distribution along a horizontal wellbore or elongated steam chamber, and is therefore important for determining the effectiveness of the heating process in the start-up phase in SAGD. Net heat flux estimation in the target formation during start-up can be difficult to measure because of uncertainties regarding heat loss in the vertical section; steam quality along the horizontal segment; distribution of steam along the wellbore; operational conditions; and additional effects of convection heating. The newly presented model can be considered analogous to pressure transient analysis of a buildup after a constant pressure drawdown. The model is based on an assumption of an infinite-acting system. This paper also proposed a new concept of a heating ring to measure the heat storage in the heated bitumen at the time of testing. Field observations were used to demonstrate how the model can be used to save heat energy, conserve steam and enhance bitumen recovery. 18 refs., 14 figs., 2 appendices.

  13. Applying a neuro-fuzzy approach for transient identification in a nuclear power plant

    International Nuclear Information System (INIS)

    Costa, Rafael G.; Mol, Antonio C.A.; Pereira, Claudio M.N.A.; Carvalho, Paulo V.R.

    2009-01-01

    Transient identification in Nuclear Power Plant (NPP) is often a very hard task and may involve a great amount of human cognition. The early identification of unexpected departures from steady state behavior is an essential step for the operation, control and accident management in NPPs. The bases for the transient identification relay on the evidence that different system faults and anomalies lead to different pattern evolution in the involved process variables. During an abnormal event, the operator must monitor a great amount of information from the instruments that represents a specific type of event. Several systems based on specialist systems, neural networks, and fuzzy logic have been developed for transient identification. In the work, we investigate the possibility of using a Neuro-Fuzzy modeling tool for efficient transient identification, aiming to helping the operator crew to take decisions relative to the procedure to be followed in situations of accidents/transients at NPPs. The proposed system uses artificial neural networks (ANN) as first level transient diagnostic. After the ANN has done the preliminary transient type identification, a fuzzy-logic system analyzes the results emitting reliability degree of it. A preliminary evaluation of the developed system was made at the Human-System Interface Laboratory (LABIHS). The obtained results show that the system can help the operators to take decisions during transients/accidents in the plant. (author)

  14. Applying the min-projection strategy to improve the transient performance of the three-phase grid-connected inverter.

    Science.gov (United States)

    Baygi, Mahdi Oloumi; Ghazi, Reza; Monfared, Mohammad

    2014-07-01

    Applying the min-projection strategy (MPS) to a three-phase grid-connected inverter to improve its transient performance is the main objective of this paper. For this purpose, the inverter is first modeled as a switched linear system. Then, the feasibility of the MPS technique is investigated and the stability criterion is derived. Hereafter, the fundamental equations of the MPS for the control of the inverter are obtained. The proposed scheme is simulated in PSCAD/EMTDC environment. The validity of the MPS approach is confirmed by comparing the obtained results with those of VOC method. The results demonstrate that the proposed method despite its simplicity provides an excellent transient performance, fully decoupled control of active and reactive powers, acceptable THD level and a reasonable switching frequency. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Ultrafast triggered transient energy storage by atomic layer deposition into porous silicon for integrated transient electronics

    Science.gov (United States)

    Douglas, Anna; Muralidharan, Nitin; Carter, Rachel; Share, Keith; Pint, Cary L.

    2016-03-01

    Here we demonstrate the first on-chip silicon-integrated rechargeable transient power source based on atomic layer deposition (ALD) coating of vanadium oxide (VOx) into porous silicon. A stable specific capacitance above 20 F g-1 is achieved until the device is triggered with alkaline solutions. Due to the rational design of the active VOx coating enabled by ALD, transience occurs through a rapid disabling step that occurs within seconds, followed by full dissolution of all active materials within 30 minutes of the initial trigger. This work demonstrates how engineered materials for energy storage can provide a basis for next-generation transient systems and highlights porous silicon as a versatile scaffold to integrate transient energy storage into transient electronics.Here we demonstrate the first on-chip silicon-integrated rechargeable transient power source based on atomic layer deposition (ALD) coating of vanadium oxide (VOx) into porous silicon. A stable specific capacitance above 20 F g-1 is achieved until the device is triggered with alkaline solutions. Due to the rational design of the active VOx coating enabled by ALD, transience occurs through a rapid disabling step that occurs within seconds, followed by full dissolution of all active materials within 30 minutes of the initial trigger. This work demonstrates how engineered materials for energy storage can provide a basis for next-generation transient systems and highlights porous silicon as a versatile scaffold to integrate transient energy storage into transient electronics. Electronic supplementary information (ESI) available: (i) Experimental details for ALD and material fabrication, ellipsometry film thickness, preparation of gel electrolyte and separator, details for electrochemical measurements, HRTEM image of VOx coated porous silicon, Raman spectroscopy for VOx as-deposited as well as annealed in air for 1 hour at 450 °C, SEM and transient behavior dissolution tests of uniformly coated VOx on

  16. Characterizing transient noise in the LIGO detectors

    Science.gov (United States)

    Nuttall, L. K.

    2018-05-01

    Data from the LIGO detectors typically contain many non-Gaussian noise transients which arise due to instrumental and environmental conditions. These non-Gaussian transients can be an issue for the modelled and unmodelled transient gravitational-wave searches, as they can mask or mimic a true signal. Data quality can change quite rapidly, making it imperative to track and find new sources of transient noise so that data are minimally contaminated. Several examples of transient noise and the tools used to track them are presented. These instances serve to highlight the diverse range of noise sources present at the LIGO detectors during their second observing run. This article is part of a discussion meeting issue `The promises of gravitational-wave astronomy'.

  17. Transient analysis on the SMART-P anticipated transients without scram

    International Nuclear Information System (INIS)

    Yang, S. H.; Bae, K. H.; Kim, H. C.; Zee, S. Q.

    2005-01-01

    Anticipated transients without scram (ATWS) are anticipated operational occurrences accompanied by a failure of an automatic reactor trip when required. Although the occurrence probability of the ATWS events is considerably low, these events can result in unacceptable consequences, i.e. the pressurization of the reactor coolant system (RCS) up to an unacceptable range and a core-melting situation. Therefore, the regulatory body requests the installation of a protection system against the ATWS events. According to the request, a diverse protection system (DPS) is installed in the SMART-P (System-integrated Modular Advanced ReacTor-Pilot). This paper presents the results of the transient analysis performed to identify the performance of the SMART-P against the ATWS. In the analysis, the TASS/SMR (Transients And Setpoint Simulation/Small and Medium Reactor) code is applied to identify the thermal hydraulic response of the RCS during the transients

  18. Droplet condensation in rapidly decaying pressure fields

    International Nuclear Information System (INIS)

    Peterson, P.F.; Bai, R.Y.; Schrock, V.E.; Hijikata, K.

    1992-01-01

    Certain promising schemes for cooling inertial confinement fusion reactors call for highly transient condensation in a rapidly decaying pressure field. After an initial period of condensation on a subcooled droplet, undesirable evaporation begins to occur. Recirculation within the droplet strongly impacts the character of this condensation-evaporation cycle, particularly when the recirculation time constant is of the order of the pressure decay time constant. Recirculation can augment the heat transfer, delay the onset of evaporation, and increase the maximum superheat inside the drop by as much as an order of magnitude. This numerical investigation identifies the most important parameters and physics characterizing transient, high heat flux droplet condensation. The results can be applied to conceptual designs of inertial confinement fusion reactors, where initial temperature differences on the order of 1,500 K decay to zero over time spans the order of tens of milliseconds

  19. Transient survivability of LMR oxide fuel pins

    International Nuclear Information System (INIS)

    Weber, E.T.; Pitner, A.L.; Bard, F.E.; Culley, G.E.; Hunter, C.W.

    1986-01-01

    Fuel pin integrity during transient events must be assessed for both the core design and safety analysis phases of a reactor project. A significant increase in the experience related to limits of integrity for oxide fuel pins in transient overpower events has been realized from testing of fuel pins irradiated in FFTF and PFR. Fourteen FFTF irradiated fuel pins were tested in TREAT, representing a range of burnups, overpower ramp rates and maximum overpower conditions. Results of these tests along with similar testing in the PFR/TREAT program, provide a demonstration of significant safety margins for oxide fuel pins. Useful information applied in analytical extrapolation of fuel pin test data have been developed from laboratory transient tests on irradiated fuel cladding (FCTT) and on unirradiated fuel pellet deformation. These refinements in oxide fuel transient performance are being applied in assessment of transient capabilities of long lifetime fuel designs using ferritic cladding

  20. Transient rheology of stimuli responsive hydrogels: Integrating microrheology and microfluidics

    Science.gov (United States)

    Sato, Jun

    Stimuli-responsive hydrogels have diverse potential applications in the field of drug delivery, tissue engineering, agriculture, cosmetics, gene therapy, and as sensors and actuators due to their unique responsiveness to external signals, such as pH, temperature, and ionic strength. Understanding the responsiveness of hydrogel structure and rheology to these stimuli is essential for designing materials with desirable performance. However, no instrumentation and well-defined methodology are available to characterize the structural and rheological responses to rapid solvent changes. In this thesis, a new microrheology set-up is described, which allows us to quantitatively measure the transient rheological properties and microstructure of a variety of solvent-responsive complex fluids. The device was constructed by integrating particle tracking microrheology and microfluidics and offers unique experimental capabilities for performing solvent-reponse measurements on soft fragile materials without applying external shear forces. Transient analysis methods to quantitatively obtain rheological properties were also constructed, and guidelines for the trade-off between statistical validity and temporal resolution were developed to accurately capture physical transitions. Employing the new device and methodology, we successfully quantified the transient rheological and microstructural responses during gel formation and break-up, and viscosity changes of solvent-responsive complex fluids. The analysis method was expanded for heterogeneous samples, incorporating methods to quantify the microrheology of samples with broad distributions of individual particle dynamics. Transient microrheology measurements of fragile, heterogeneous, self-assembled block copolypeptide hydrogels revealed that solvent exchange via convective mixing and dialysis can lead to significantly different gel properties and that commonly applied sample preparation protocols for the characterization of soft

  1. HTGR-GT primary coolant transient resulting from postulated turbine deblading

    International Nuclear Information System (INIS)

    Cadwallader, G.J.; Deremer, R.K.

    1980-11-01

    The turbomachine is located within the primary coolant system of a nuclear closed cycle gas turbine plant (HTGR-GT). The deblading of the turbine can cause a rapid pressure equilibration transient that generates significant loads on other components in the system. Prediction of and design for this transient are important aspects of assuring the safety of the HTGR-GT. This paper describes the adaptation and use of the RATSAM program to analyze the rapid fluid transient throughout the primary coolant system during a spectrum of turbine deblading events. Included are discussions of (1) specific modifications and improvements to the basic RATSAM program, which is also briefly described; (2) typical results showing the expansion wave moving upstream from the debladed turbine through the primary coolant system; and (3) the effect on the transient results of different plenum volumes, flow resistances, times to deblade, and geometries that can choke the flow

  2. Transient elastography with the XL probe rapidly identifies patients with nonhepatic ascites

    Directory of Open Access Journals (Sweden)

    Mueller S

    2012-05-01

    Full Text Available Anna Kohlhaas1, Esteban Durango1, Gunda Millonig1, Cecile Bastard2, Laurent Sandrin2, Mohammad Golriz3, Arianeb Mehrabi3, Markus W Büchler3, Helmut Karl Seitz1, Sebastian Mueller11Department of Medicine and Center for Alcohol Research, Liver Disease and Nutrition, Salem Medical Center, University of Heidelberg, Heidelberg, Germany; 2Department of Research and Development, Echosens, Paris, France; 3Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Heidelberg, GermanyBackground: In contrast with other elastographic techniques, ascites is considered an exclusion criterion for assessment of fibrosis stage by transient elastography. However, a normal liver stiffness could rule out hepatic causes of ascites at an early stage. The aim of the present study was to determine whether liver stiffness can be generally determined by transient elastography through an ascites layer, to determine whether the ascites-mediated increase in intra-abdominal pressure affects liver stiffness, and to provide initial data from a pilot cohort of patients with various causes of ascites.Methods and results: Using the XL probe in an artificial ascites model, we demonstrated (copolymer phantoms surrounded by water that a transient elastography-generated shear wave allows accurate determination of phantom stiffness up to a water lamella of 20 mm. We next showed in an animal ascites model that increased intra-abdominal pressure does not affect liver stiffness. Liver stiffness was then determined in 24 consecutive patients with ascites due to hepatic (n = 18 or nonhepatic (n = 6 causes. The cause of ascites was eventually clarified using routine clinical, imaging, laboratory, and other tools. Valid (75% or acceptable (25% liver stiffness data could be obtained in 23 patients (95.8% with ascites up to an ascites lamella of 39 mm. The six patients (25% with nonhepatic causes of ascites (eg, pancreatitis, peritoneal carcinomatosis had a

  3. A SEARCH FOR RAPIDLY SPINNING PULSARS AND FAST TRANSIENTS IN UNIDENTIFIED RADIO SOURCES WITH THE NRAO 43 METER TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Deborah; Crawford, Fronefield; Gilpin, Claire [Department of Physics and Astronomy, Franklin and Marshall College, P.O. Box 3003, Lancaster, PA 17604 (United States); Langston, Glen [National Radio Astronomy Observatory, P.O. Box 2, Green Bank, WV 24944 (United States)

    2013-04-15

    We have searched 75 unidentified radio sources selected from the NRAO VLA Sky Survey catalog for the presence of rapidly spinning pulsars and short, dispersed radio bursts. The sources are radio bright, have no identifications or optical source coincidences, are more than 5% linearly polarized, and are spatially unresolved in the catalog. If these sources are fast-spinning pulsars (e.g., sub-millisecond pulsars), previous large-scale pulsar surveys may have missed detection due to instrumental and computational limitations, eclipsing effects, or diffractive scintillation. The discovery of a sub-millisecond pulsar would significantly constrain the neutron star equation of state and would have implications for models predicting a rapid slowdown of highly recycled X-ray pulsars to millisecond periods from, e.g., accretion disk decoupling. These same sources were previously searched unsuccessfully for pulsations at 610 MHz with the Lovell Telescope at Jodrell Bank. This new search was conducted at a different epoch with a new 800 MHz backend on the NRAO 43 m Telescope at a center frequency of 1200 MHz. Our search was sensitive to sub-millisecond pulsars in highly accelerated binary systems and to short transient pulses. No periodic or transient signals were detected from any of the target sources. We conclude that diffractive scintillation, dispersive smearing, and binary acceleration are unlikely to have prevented detection of the large majority of the sources if they are pulsars, though we cannot rule out eclipsing, nulling or intermittent emission, or radio interference as possible factors for some non-detections. Other (speculative) possibilities for what these sources might include radio-emitting magnetic cataclysmic variables or older pulsars with aligned magnetic and spin axes.

  4. Towards a utilisation of transient processing in the technology of high efficiency silicon solar cells

    International Nuclear Information System (INIS)

    Eichhammer, W.

    1989-01-01

    The utilization of transient processing in the technology of high efficient silicon solar cells is investigated. An ultraviolet laser (an ArF pulsed excimer laser working at 193 nm) is applied. Laser processing induces only a short superficial melting of the material and does not modify the transport properties in the base of the material. This mode of processing associated to ion implantation to form the junction as well as an oxide layer in an atmosphere of oxygen. The volume was left entirely cold in this process. The results of the investigation show: that an entirely cold process of solar cell fabrication needs a thermal treatment at a temperature around 600 C; that the oxides obtained are not satisfying as passivating layers; and that the Rapid Thermal Processing (RTP) induced recombination centers are not directly related to the quenching step but a consequence of the presence of metal impurities. The utilisation of transient processing in the adiabatic regime (laser) and in the rapid isothermal regime (RTP) are possible as two complementary techniques for the realization of high efficiency solar cells

  5. Analysis of the FFTF primary pipe rupture transients

    International Nuclear Information System (INIS)

    Perkins, K.R.; Bari, R.A.; Chen, L.C.; Albright, D.C.

    1979-01-01

    The response of the Fast Flux Test Facility (FFTF) to hypothetical ruptures of the high pressure primary piping has been analyzed using two LMFBR plant systems codes, namely IANUS and DEMO. Comparisons of the average channel temperatures predicted by the two codes show good agreement for identical transients. However, the hot channel temperatures predicted by DEMO are about 60K higher than the corresponding IANUS predictions for severe transients. This difference is attributed to the dynamic hot channel factors employed in DEMO which discount the thermal inertia of the duct walls for rapid transients. DEMO also predicts more severe transients for hot-leg ruptures in FFTF than previously reported analyses for the CRBR

  6. Studies on an Electromagnetic Transient Model of Offshore Wind Turbines and Lightning Transient Overvoltage Considering Lightning Channel Wave Impedance

    Directory of Open Access Journals (Sweden)

    Li Zhang

    2017-12-01

    Full Text Available In recent years, with the rapid development of offshore wind turbines (WTs, the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs, the influencing factors and the response rules of transient overvoltage are analyzed. In this paper, a new integrated electromagnetic transient model of offshore WTs is established by using the numerical calculation method of the electromagnetic field first. Then, based on the lightning model and considering the impedance of the lightning channel, the transient overvoltage of lightning is analyzed. Last, the electromagnetic transient model of offshore WTs is simulated and analyzed by using the alternative transients program electro-magnetic transient program (ATP-EMTP software. The influence factors of lightning transient overvoltage are studied. The main influencing factors include the sea depth, the blade length, the tower height, the lightning flow parameters, the lightning strike point, and the blade rotation position. The simulation results show that the influencing factors mentioned above have different effects on the lightning transient overvoltage. The results of the study have some guiding significance for the design of the lightning protection of the engine room.

  7. Transient Analysis and Dosimetry of the Tokaimura Criticality Incident

    International Nuclear Information System (INIS)

    Pain, Christopher C.; Oliveira, Cassiano R.E. de; Goddard, Antony J. H.; Eaton, Matthew D.; Gundry, Sarah; Umpleby, Adrian P.

    2003-01-01

    This paper describes research on the application of the finite element transient criticality (FETCH) code to modeling and neutron dosimetry of the Tokaimura criticality incident. FETCH has been developed to model criticality transients in single and multiphase media and is applied here to fissile solution transient criticality. Since the initial transient behavior has different time scales and physics to the longer transient behavior, the transient modeling is divided into two parts: modeling the initial transient over a time scale of seconds in which radiolytic gases and free-surface sloshing play an important role in the transient - this provides information about the dose to workers; and modeling the long-term transient behavior following the initial transient that has a time scale over hours.The neutron dosimetry of worker A who received the largest dose during the Tokaimura criticality incident is also investigated here. This dose was received mainly in the first few seconds of the ensuing nuclear criticality transient. In addition to the multiorgan dosimetry of worker A, this work provides a method of helping to evaluate the yield in the initial phase of the criticality incident; it also shows how kinetic simulations can be calibrated so that they can be applied to investigate the physics behind the incident

  8. Temperature shock, injury and transient sensitivity to nisin in Gram negatives.

    Science.gov (United States)

    Boziaris, I S; Adams, M R

    2001-10-01

    The effect of thermal stresses on survival, injury and nisin sensitivity was investigated in Salmonella Enteritidis PT4, PT7 and Pseudomonas aeruginosa. Heating at 55 degrees C, rapid chilling to 0.5 degrees C or freezing at -20 degrees C produced transient sensitivity to nisin. Cells were only sensitive if nisin was present during stress. Resistance recovered rapidly afterwards, though some cells displayed residual injury. Injury was assessed by SDS sensitivity, hydrophobicity changes, lipopolysaccharide release and NPN uptake. LPS release and hydrophobicity were not always associated with transient nisin sensitivity. Uptake of NPN correlated better but persisted longer after treatment. Thermal shocks produce transient injury to the outer membrane, allowing nisin access. After treatment, the permeability barrier is rapidly restored by a process apparently involving reorganization rather than biosynthetic repair. Inclusion of nisin during food treatments that impose sub-lethal stress on Gram negatives could increase process lethality, enhancing microbiological safety and stability.

  9. FARST: A computer code for the evaluation of FBR fuel rod behavior under steady-state/transient conditions

    International Nuclear Information System (INIS)

    Nakamura, M.; Sakagami, M.

    1984-01-01

    FARST, a computer code for the evaluation of fuel rod thermal and mechanical behavior under steady-state/transient conditions has been developed. The code characteristics are summarized as follows: (I) FARST evaluates the fuel rod behavior under the transient conditions. The code analyzes thermal and mechanical phenomena within a fuel rod, taking into account the temperature change in coolant surrounding the fuel rod. (II) Permanent strains such as plastic, creep and swelling strains as well as thermoelastic deformations can be analyzed by using the strain increment method. (III) Axial force and contact pressure which act on the fuel stack and cladding are analyzed based on the stick/slip conditions. (IV) FARST used a pellet swelling model which depends on the contact pressure between pellet and cladding, and an empirical pellet relocation model, designated as 'jump relocation model'. The code was successfully applied to analyses of the fuel rod irradiation data from pulse reactor for nuclear safety research in Cadarache (CABRI) and pulse reactor for nuclear safety research in Japan Atomic Energy Research Institute (NSRR). The code was further applied to stress analysis of a 1000 MW class large FBR plant fuel rod during transient conditions. The steady-state model which was used so far gave the conservative results for cladding stress during overpower transient, but underestimated the results for cladding stress during a rapid temperature decrease of coolant. (orig.)

  10. Analysis of transient signals by Wavelet transform

    International Nuclear Information System (INIS)

    Penha, Rosani Libardi da; Silva, Aucyone A. da; Ting, Daniel K.S.; Oliveira Neto, Jose Messias de

    2000-01-01

    The objective of this work is to apply the Wavelet Transform in transient signals. The Wavelet technique can outline the short time events that are not easily detected using traditional techniques. In this work, the Wavelet Transform is compared with Fourier Transform, by using simulated data and rotor rig data. This data contain known transients. The wavelet could follow all the transients, what do not happen to the Fourier techniques. (author)

  11. Rapidly Rising Optical Transients from the Birth of Binary Neutron Stars

    Science.gov (United States)

    Hotokezaka, Kenta; Kashiyama, Kazumi; Murase, Kohta

    2017-11-01

    We study optical counterparts of a new-born pulsar in a double neutron star system like PSR J0737-3039A/B. This system is believed to have ejected a small amount of mass of { O }(0.1 {M}⊙ ) at the second core-collapse supernova. We argue that the initial spin of the new-born pulsar can be determined by the orbital period at the time when the second supernova occurs. The spin angular momentum of the progenitor is expected to be similar to that of the He-burning core, which is tidally synchronized with the orbital motion, and then the second remnant may be born as a millisecond pulsar. If the dipole magnetic field strength of the nascent pulsar is comparable with that inferred from the current spin-down rate of PSR J0737-3039B, the initial spin-down luminosity is comparable to the luminosity of super-luminous supernovae. We consider thermal emission arising from the supernova ejecta driven by the relativistic wind from such a new-born pulsar. The resulting optical light curves have a rise time of ˜10 days and a peak luminosity of ˜1044 erg s-1. The optical emission may last for a month to several months, due to the reprocessing of X-rays and UV photons via photoelectric absorption. These features are broadly consistent with those of the rapidly rising optical transients. The high spin-down luminosity and small ejecta mass are favorable for the progenitor of the repeating fast radio burst, FRB 121102. We discuss a possible connection between new-born double pulsars and fast radio bursts.

  12. Real-time Automatic Search for Multi-wavelength Counterparts of DWF Transients

    Science.gov (United States)

    Murphy, Christopher; Cucchiara, Antonino; Andreoni, Igor; Cooke, Jeff; Hegarty, Sarah

    2018-01-01

    The Deeper Wider Faster (DWF) survey aims to find and classify the fastest transients in the Universe. DWF utilizes the Dark Energy Camera (DECam), collecting a continuous sequence of 20s images over a 3 square degree field of view.Once an interesting transient is detected during DWF observations, the DWF collaboration has access to several facilities for rapid follow-up in multiple wavelengths (from gamma to radio).An online web tool has been designed to help with real-time visual classification of possible astrophysical transients in data collected by the DWF observing program. The goal of this project is to create a python-based code to improve the classification process by querying several existing archive databases. Given the DWF transient location and search radius, the developed code will extract a list of possible counterparts and all available information (e.g. magnitude, radio fluxes, distance separation).Thanks to this tool, the human classifier can make a quicker decision in order to trigger the collaboration rapid-response resources.

  13. OGLE-IV Transient Search summary of season 2015b

    Science.gov (United States)

    Wyrzykowski, L.; Kostrzewa-Rutkowska, Z.; Klencki, J.; Sitek, M.; Mroz, P.; Udalski, A.; Kozlowski, S.; Skowron, J.; Poleski, R.; Szymanski, M. K.; Pietrzynski, G.; Soszynski, I.; Ulaczyk, K.; Pietrukowicz, P.

    2015-12-01

    The OGLE-IV Transient Detection System (Wyrzykowski et al. 2014, AcA,64,197; Kozlowski et al. 2013) in the 2015b transient observing season (from August) has been operating in dual mode: regular as in previous years (detections every couple of days based on at least two positive detections), and rapid (automatised detections within 15 mins after the single frame was taken, details in Klencki et al. in prep.).

  14. Predictor-Corrector Quasi-Static Method Applied to Nonoverlapping Local/Global Iterations with 2-D/1-D Fusion Transport Kernel and p-CMFD Wrapper for Transient Reactor Analysis

    International Nuclear Information System (INIS)

    Cho, Bumhee; Cho, Nam Zin

    2015-01-01

    In this study, the steady-state p-CMFD adjoint flux is used as the weighting function to obtain PK parameters instead of the computationally expensive transport adjoint angular flux. Several numerical problems are investigated to see the capability of the PCQS method applied to the NLG iteration. CRX-2K adopts the nonoverlapping local/global (NLG) iterative method with the 2-D/1-D fusion transport kernel and the global p-CMFD wrapper. The parallelization of the NLG iteration has been recently implemented in CRX-2K and several numerical results are reported in a companion paper. However, the direct time discretization leads to a fine time step size to acquire an accurate transient solution, and the step size involved in the transport transient calculations is millisecond-order. Therefore, the transient calculations need much longer computing time than the steady-state calculation. To increase the time step size, Predictor-Corrector Quasi-Static (PCQS) method can be one option to apply to the NLG iteration. The PCQS method is a linear algorithm, so the shape function does not need to be updated more than once at a specific time step like a conventional quasi-static (QS) family such as Improved Quasi-Static (IQS) method. Moreover, the shape function in the PCQS method directly comes from the direct transport calculation (with a large time step), so one can easily implement the PCQS method in an existing transient transport code. Any QS method needs to solve the amplitude function in the form of the point kinetics (PK) equations, and accurate PK parameters can be obtained by the transport steady-state adjoint angular flux as a weighting function. The PCQS method is applied to the transient NLG iteration with the 2-D/1-D fusion transport kernel and the global p-CMFD wrapper, and has been implemented in CRX-2K. In the numerical problems, the PCQS method with the NLG iteration shows more accurate solutions compared to the direct transient calculations with large time step

  15. Experimental study on transient boiling heat transfer

    International Nuclear Information System (INIS)

    Visentini, R.

    2012-01-01

    Boiling phenomena can be found in the everyday life, thus a lot of studies are devoted to them, especially in steady state conditions. Transient boiling is less known but still interesting as it is involved in the nuclear safety prevention. In this context, the present work was supported by the French Institute of Nuclear Safety (IRSN). In fact, the IRSN wanted to clarify what happens during a Reactivity-initiated Accident (RIA). This accident occurs when the bars that control the nuclear reactions break down and a high power peak is passed from the nuclear fuel bar to the surrounding fluid. The temperature of the nuclear fuel bar wall increases and the fluid vaporises instantaneously. Previous studies on a fuel bar or on a metal tube heated by Joule effect were done in the past in order to understand the rapid boiling phenomena during a RIA. However, the measurements were not really accurate because the measurement techniques were not able to follow rapid phenomena. The main goal of this work was to create an experimental facility able to simulate the RIA boiling conditions but at small scale in order to better understand the boiling characteristics when the heated-wall temperature increases rapidly. Moreover, the experimental set-up was meant to be able to produce less-rapid transients as well, in order to give information on transient boiling in general. The facility was built at the Fluid-Mechanics Institute of Toulouse. The core consists of a metal half-cylinder heated by Joule effect, placed in a half-annulus section. The inner half cylinder is made of a 50 microns thick stainless steel foil. Its diameter is 8 mm, and its length 200 mm. The outer part is a 34 mm internal diameter glass half cylinder. The semi-annular section is filled with a coolant, named HFE7000. The configuration allows to work in similarity conditions. The heated part can be place inside a loop in order to study the flow effect. The fluid temperature influence is taken into account as

  16. The effects of transient conditions on the onset of intermittent dryout during blowdown

    Energy Technology Data Exchange (ETDEWEB)

    Statham, B.A., E-mail: stathaba@mcmaster.ca; Novog, D.R., E-mail: novog@mcmaster.ca

    2017-06-15

    Highlights: • This papers presents the results of an experimental investigation of transient critical heat flux in high quality and intermediate pressure water. • In existing literature conclusions vary from those showing no effect of transient conditions to results which show 30–40% improvement in CHF. • Along with new CHF data points in the liquid film dominated flow regime, the authors provide a methodology for producing bias free estimates of CHF based on existing correlations. • With these bias free CHF estimates, comparisons are made between transient and steady-state CHF at comparable local conditions. • The work concludes that based on consistently collected and analyzed data that quasi-steady CHF experiments adequately predict transient CHF using the same local thermalhydraulic conditions. - Abstract: For a given set of conditions in a boiling system the point of liquid film dryout or departure from nucleate boiling corresponds to the change from convective or nucleate boiling to transition or film boiling. This change is associated with a rapid deterioration of the heat transfer coefficient and the heat flux at this transition is denoted the critical heat flux (CHF). Computer models used to predict station transients and CHF rely heavily on empirical correlations to predict the CHF. Liquid film CHF data are usually obtained using a quasi-steady method wherein the heat flux is incremented in small steps with each step being allowed to reach a new equilibrium until an abnormal temperature increase is detected on the experimental surfaces. In applying a correlation derived from steady-state experiments to transient analyses these codes implicitly assume that dryout will occur for the same local conditions during transients as during steady state conditions. There is some disagreement in literature as to the validity of this hypothesis. This paper provides new steady-state and transient experimental data for CHF in water at intermediate pressures

  17. Transient FDTD simulation validation

    OpenAIRE

    Jauregui Tellería, Ricardo; Riu Costa, Pere Joan; Silva Martínez, Fernando

    2010-01-01

    In computational electromagnetic simulations, most validation methods have been developed until now to be used in the frequency domain. However, the EMC analysis of the systems in the frequency domain many times is not enough to evaluate the immunity of current communication devices. Based on several studies, in this paper we propose an alternative method of validation of the transients in time domain allowing a rapid and objective quantification of the simulations results.

  18. Opto-thermal transient emission radiometry for rapid, non-destructive and non-contact determination of hydration and hydration depth profile in the skin of a grape

    NARCIS (Netherlands)

    Guo, X.; Bicanic, D.D.; Keijser, K.; Imhof, R.

    2003-01-01

    .The concept of optothermal transient emission radiometry at a wavelength of 2.94 µm was applied to non-destructively determine the level of hydration and the profile of hydration in the skin of intact fresh grapes taken from top and bottom sections of the same bunch.

  19. Mining the Sky for Explosive Optical Transients with Both Eyes Open

    International Nuclear Information System (INIS)

    Vestrand, W.T.; Casperson, D.J.; Davis, H.; Fenimore, E.; Galassi, M.; White, R.R.; Wren, J.; Borozdin, K.; Davidoff, S.; McGowan, K.; Starr, D.; Wozniak, P.

    2004-01-01

    While it has been known for centuries that the optical sky is variable, monitoring the sky for optical transients with durations as short as a minute is an area of astronomical research that remains largely unexplored. Prompt follow-up observations of Gamma Ray Bursts have shown that bright, explosive, optical transients exist. However, there are many reasons to suspect the existence of explosive optical transients that cannot be located through sky monitoring by high-energy satellites. The RAPTOR sky monitoring system is an autonomous system of telescope arrays at Los Alamos National Laboratory that identifies fast optical transients as short as a minute and makes follow-up observations in real time. The core of the RAPTOR system is composed of two arrays of telescopes, separated by 38 kilometers, that stereoscopically monitor a field of about 1300 square degrees for transients down to about 12.5th magnitude in 30 seconds. Both arrays are coupled to real-time data analysis pipelines that are designed to identify transients on timescales of seconds. Each telescope array also contains a more sensitive higher resolution 'fovea' telescope, capable of both measuring the light curve at a faster cadence and providing color information. In a manner analogous to human vision, each array is mounted on a rapidly slewing mount so that the 'fovea' of the array can be rapidly directed for real-time follow-up observations of any interesting transient identified by the wide-field system. We discuss the first results from RAPTOR and show that stereoscopic imaging and the absence of measurable parallax is a powerful tool for distinguishing real celestial transients in the 'forest' of false positives

  20. A fast reactor transient analysis methodology for personal computers

    International Nuclear Information System (INIS)

    Ott, K.O.

    1993-01-01

    A simplified model for a liquid-metal-cooled reactor (LMR) transient analysis, in which point kinetics as well as lumped descriptions of the heat transfer equations in all components are applied, is converted from a differential into an integral formulation. All 30 differential balance equations are implicitly solved in terms of convolution integrals. The prompt jump approximation is applied as the strong negative feedback effectively keeps the net reactivity well below prompt critical. After implicit finite differencing of the convolution integrals, the kinetics equation assumes a new form, i.e., the quadratic dynamics equation. In this integral formulation, the initial value problem of typical LMR transients can be solved with large item steps (initially 1 s, later up to 256 s). This then makes transient problems amenable to a treatment on personal computer. The resulting mathematical model forms the basis for the GW-BASIC program LMR transient calculation (LTC) program. The LTC program has also been converted to QuickBASIC. The running time for a 10-h transient overpower transient is then ∼40 to 10 s, depending on the hardware version (286, 386, or 486 with math coprocessors)

  1. Fuel cladding mechanical properties for transient analysis

    International Nuclear Information System (INIS)

    Johnson, G.D.; Hunter, C.W.; Hanson, J.E.

    1976-01-01

    Out-of-pile simulated transient tests have been conducted on irradiated fast-reactor fuel pin cladding specimens at heating rates of 10 0 F/s (5.6 0 K/s) and 200 0 F/s (111 0 K/s) to generate mechanical property information for use in describing cladding behavior during off-normal events. Mechanical property data were then analyzed, applying the Larson-Miller Parameter to the effects of heating rate and neutron fluence. Data from simulated transient tests on TREAT-tested fuel pins demonstrate that Plant Protective System termination of 3$/s transients prevents significant damage to cladding. The breach opening produced during simulated transient testing is shown to decrease in size with increasing neutron fluence

  2. DRAFTS: A DEEP, RAPID ARCHIVAL FLARE TRANSIENT SEARCH IN THE GALACTIC BULGE

    International Nuclear Information System (INIS)

    Osten, Rachel A.; Sahu, Kailash; Kowalski, Adam; Hawley, Suzanne L.

    2012-01-01

    We utilize the Sagittarius Window Eclipsing Extrasolar Planet Search Hubble Space Telescope/Advanced Camera for Surveys data set for a Deep Rapid Archival Flare Transient Search to constrain the flare rate toward the older stellar population in the Galactic bulge. During seven days of monitoring 229,293 stars brighter than V = 29.5, we find evidence for flaring activity in 105 stars between V = 20 and V = 28. We divided the sample into non-variable stars and variable stars whose light curves contain large-scale variability. The flare rate on variable stars is ∼700 times that of non-variable stars, with a significant correlation between the amount of underlying stellar variability and peak flare amplitude. The flare energy loss rates are generally higher than those of nearby well-studied single dMe flare stars. The distribution of proper motions is consistent with the flaring stars being at the distance and age of the Galactic bulge. If they are single dwarfs, then they span a range of ≈1.0-0.25 M ☉ . A majority of the flaring stars exhibit periodic photometric modulations with P < 3 days. If these are tidally locked magnetically active binary systems, then their fraction in the bulge is enhanced by a factor of ∼20 compared to the local value. These stars may be useful for placing constraints on the angular momentum evolution of cool close binary stars. Our results expand the type of stars studied for flares in the optical band, and suggest that future sensitive optical time-domain studies will have to contend with a larger sample of flaring stars than the M dwarf flare stars usually considered.

  3. A fast reactor transient analysis methodology for PCs

    International Nuclear Information System (INIS)

    Ott, K.O.

    1991-10-01

    This Manual describes a PC program for LMR Transient Calculations, LTC, written in GW-BASIC. It calculates the power and temperature trajectories for unscrammed TOP and LOHS transients. The LOF transient treatment is not operational in the GW-BASIC program because of storage limitations. The corresponding mathematical model, which allows a rapid treatment of the kinetics and the various feedback effects, is described in Ref. 1. It is briefly reviewed in Sec. 1. The program structure is outlined in Sec. 2, followed by a more detailed description in Sec. 3. Computational details are presented in Appendix A. A complete listing of the GW-BASIC program is given in Appendix B. Appendix C shows input-echo and output for a TOP sample problem, and Appendix D is a Glossary of all quantities used in the LTC program. The limitations of the GW-BASIC storage (to about 60K) are removed if it is run within Quick-BASIC. This then allows the extension of this program to treat LOF transients. Running LTC in Quick-BASIC permits also larger ''Dimensions'' for TOP and LOHS transients

  4. Optimization of Agrobacterium-mediated transient expression of heterologous genes in spinach

    DEFF Research Database (Denmark)

    Cao, Dang Viet; Pamplona, Reniel S.; Kim, Jiwon

    2017-01-01

    The Agrobacterium-mediated transient assay is a relatively rapid technique and a promising approach for assessing the expression of a gene of interest. Despite the successful application of this transient expression system in several plant species, it is not well understood in spinach. In this st...

  5. Experimental Setup with Transient Behavior of Fuel Cladding of SFR

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Hun; Kim, Jun Hwan; Kim, June-Hyung; Ryu, Woo Seog; Park, Sang Gyu; Kim, Sung Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Nowadays, in Korea, advanced cladding such as FC92 is developed and its transient behaviors are required for the safety analysis of SFR. Design and safety analyses of sodium-cooled fast reactor (SFR) require understanding fuel pin responses to a wide range of off-normal events. In a loss-of-flow (LOF) or transient over-power (TOP), the temperature of the cladding is rapidly increased above its steady-state service temperature. Transient tests have been performed in sections of fuel pin cladding and a large data base has been established for austenitic stainless steel such as 20% cold-worked 316 SS and ferritic/martensitic steels such as HT9. This paper summarizes the technical status of transient testing facilities and their results. Previous researches showed the transient behaviors of HT9 cladding. For the safety analyses in SFR in Korea, simulated transient tests with newly developed FC92 as well as HT9 cladding are being carried out.

  6. Excitation of neutron flux waves in reactor core transients

    International Nuclear Information System (INIS)

    Carew, J.F.; Neogy, P.

    1983-01-01

    An analysis of the excitation of neutron flux waves in reactor core transients has been performed. A perturbation theory solution has been developed for the time-dependent thermal diffusion equation in which the absorption cross section undergoes a rapid change, as in a PWR rod ejection accident (REA). In this analysis the unperturbed reactor flux states provide the basis for the spatial representation of the flux solution. Using a simplified space-time representation for the cross section change, the temporal integrations have been carried out and analytic expressions for the modal flux amplitudes determined. The first order modal excitation strength is determined by the spatial overlap between the initial and final flux states, and the cross section perturbation. The flux wave amplitudes are found to be largest for rapid transients involving large reactivity perturbations

  7. Transient subcritical crack-growth behavior in transformation-toughened ceramics

    International Nuclear Information System (INIS)

    Dauskardt, R.H.; Ritchie, R.O.; Carter, W.C.; Veirs, D.K.

    1990-01-01

    Transient subcritical crack-growth behavior following abrupt changes in the applied load are studied in transformation-toughened ceramics. A mechanics analysis is developed to model the transient nature of transformation shielding of the crack tip, K s , with subcritical crack extension following the applied load change. conditions for continued crack growth, crack growth followed by arrest, and no crack growth after the load change, are considered and related to the magnitude and sign of the applied load change and to materials properties such as the critical transformation stress. The analysis is found to provide similar trends in K s compared to values calculated from experimentally measured transformation zones in a transformation-toughened Mg-PSZ. In addition, accurate prediction of the post load-change transient crack-growth behavior is obtained using experimentally derived steady-state subcritical crack-growth relationships for cyclic fatigue in the same material

  8. Prevention device for rapid reactor core shutdown in BWR type reactors

    International Nuclear Information System (INIS)

    Koshi, Yuji; Karatsu, Hiroyuki.

    1986-01-01

    Purpose: To surely prevent rapid shutdown of a nuclear reactor upon partial load interruption due to rapid increase in the system frequency. Constitution: If a partial load interruption greater than the sum of the turbine by-pass valve capacity and the load setting bias portion is applied in a BWR type power plant, the amount of main steams issued from the reactor is decreased, the thermal input/output balance of the reactor is lost, the reactor pressure is increased, the void is collapsed, the neutron fluxes are increased and the reactor power rises to generate rapid reactor shutdown. In view of the above, the turbine speed signal is compared with a speed setting value in a recycling flowrate control device and the recycling pump is controlled to decrease the recycling flowrate in order to compensate the increase in the neutron fluxes accompanying the reactor power up. In this way, transient changes in the reactor core pressure and the neutron fluxes are kept within a setting point for the rapid reactor shutdown operation thereby enabling to continue the plant operation. (Horiuchi, T.)

  9. Study on the Cross Plane Thermal Transport of Polycrystalline Molybdenum Nanofilms by Applying Picosecond Laser Transient Thermoreflectance Method

    Directory of Open Access Journals (Sweden)

    Tingting Miao

    2014-01-01

    Full Text Available Thin metal films are widely used as interconnecting wires and coatings in electronic devices and optical components. Reliable thermophysical properties of the films are required from the viewpoint of thermal management. The cross plane thermal transport of four polycrystalline molybdenum nanofilms with different thickness deposited on glass substrates has been studied by applying the picosecond laser transient thermoreflectance technique. The measurement is performed by applying both front pump-front probe and rear pump-front probe configurations with high quality signal. The determined cross plane thermal diffusivity of the Mo films greatly decreases compared to the corresponding bulk value and tends to increase as films become thicker, exhibiting significant size effect. The main mechanism responsible for the thermal diffusivity decrease of the present polycrystalline Mo nanofilms is the grain boundary scattering on the free electrons. Comparing the cross plane thermal diffusivity and inplane electrical conductivity indicates the anisotropy of the transport properties of the Mo films.

  10. Transmitter modulation of spike-evoked calcium transients in arousal related neurons

    DEFF Research Database (Denmark)

    Kohlmeier, Kristi Anne; Leonard, Christopher S

    2006-01-01

    Nitric oxide synthase (NOS)-containing cholinergic neurons in the laterodorsal tegmentum (LDT) influence behavioral and motivational states through their projections to the thalamus, ventral tegmental area and a brainstem 'rapid eye movement (REM)-induction' site. Action potential-evoked intracel......Nitric oxide synthase (NOS)-containing cholinergic neurons in the laterodorsal tegmentum (LDT) influence behavioral and motivational states through their projections to the thalamus, ventral tegmental area and a brainstem 'rapid eye movement (REM)-induction' site. Action potential......-evoked intracellular calcium transients dampen excitability and stimulate NO production in these neurons. In this study, we investigated the action of several arousal-related neurotransmitters and the role of specific calcium channels in these LDT Ca(2+)-transients by simultaneous whole-cell recording and calcium...... of cholinergic LDT neurons and that inhibition of spike-evoked Ca(2+)-transients is a common action of neurotransmitters that also activate GIRK channels in these neurons. Because spike-evoked calcium influx dampens excitability, our findings suggest that these 'inhibitory' transmitters could boost firing rate...

  11. Prenatal Diagnosis of Transient Abnormal Myelopoiesis in a Down Syndrome Fetus

    International Nuclear Information System (INIS)

    Kim, Gwang Jun; Lee, Eun Sil

    2009-01-01

    We report a case of transient abnormal myelopoiesis in a Down syndrome fetus diagnosed at 28 +3 weeks of gestation that rapidly progressed to intrauterine death 10 days later. Fetal hepatosplenomegaly with cerebral ventriculomegaly, although not specific, may be a suggestive finding of Down syndrome with transient abnormal myelopoiesis. Prompt fetal blood sampling for liver function test and chromosomal analysis are mandatory for early detection and management

  12. [A hydroponic cultivation system for rapid high-yield transient protein expression in Nicotiana plants under laboratory conditions].

    Science.gov (United States)

    Mo, Qianzhen; Mai, Rongjia; Yang, Zhixiao; Chen, Minfang; Yang, Tiezhao; Lai, Huafang; Yang, Peiliang; Chen, Qiang; Zhou, Xiaohong

    2012-06-01

    To develop a hydroponic Nicotiana cultivation system for rapid and high-yield transient expression of recombinant proteins under laboratory conditions. To establish the hydroponic cultivation system, several parameters were examined to define the optimal conditions for the expression of recombinant proteins in plants. We used the green fluorescent protein (GFP) and the geminiviral plant transient expression vector as the model protein/expression vector. We examined the impact of Nicotiana species, the density and time of Agrobacterium infiltration, and the post-infiltration growth period on the accumulation of GFP. The expression levels of GFP in Nicotiana leaves were then examined by Western blotting and ELISA. Our data indicated that a hydroponic Nicotiana cultivation system with a light intensity of 9000 LX/layer, a light cycle of 16 h day/8 h night, a temperature regime of 28 degrees celsius; day/21 degrees celsius; night, and a relative humidity of 80% could support the optimal plant growth and protein expression. After agroinfiltration with pBYGFPDsRed.R/LBA4404, high levels of GFP expression were observed in both N. benthamiana and N. tobaccum (cv. Yuyan No.5) plants cultured with this hydroponic cultivation system. An optimal GFP expression was achieved in both Nicotiana species leaves 4 days after infiltration by Agrobacterium with an OD(600) of 0.8. At a given time point, the average biomass of N. tobaccum (cv. Yuyan No.5) was significantly higher than that of N. benthamiana. The leaves from 6-week-old N. benthamiana plants and 5-week-old N. tobaccum (cv. Yuyan No.5) plants could be the optimal material for agroinfiltration. We have established a hydroponic cultivation system that allows robust growth of N. benthamiana and N. tobaccum (cv. Yuyan No.5) plants and the optimal GFP expression in the artificial climate box.

  13. Advanced Instrumentation for Transient Reactor Testing

    Energy Technology Data Exchange (ETDEWEB)

    Corradini, Michael L.; Anderson, Mark; Imel, George; Blue, Tom; Roberts, Jeremy; Davis, Kurt

    2018-01-31

    Transient testing involves placing fuel or material into the core of specialized materials test reactors that are capable of simulating a range of design basis accidents, including reactivity insertion accidents, that require the reactor produce short bursts of intense highpower neutron flux and gamma radiation. Testing fuel behavior in a prototypic neutron environment under high-power, accident-simulation conditions is a key step in licensing nuclear fuels for use in existing and future nuclear power plants. Transient testing of nuclear fuels is needed to develop and prove the safety basis for advanced reactors and fuels. In addition, modern fuel development and design increasingly relies on modeling and simulation efforts that must be informed and validated using specially designed material performance separate effects studies. These studies will require experimental facilities that are able to support variable scale, highly instrumented tests providing data that have appropriate spatial and temporal resolution. Finally, there are efforts now underway to develop advanced light water reactor (LWR) fuels with enhanced performance and accident tolerance. These advanced reactor designs will also require new fuel types. These new fuels need to be tested in a controlled environment in order to learn how they respond to accident conditions. For these applications, transient reactor testing is needed to help design fuels with improved performance. In order to maximize the value of transient testing, there is a need for in-situ transient realtime imaging technology (e.g., the neutron detection and imaging system like the hodoscope) to see fuel motion during rapid transient excursions with a higher degree of spatial and temporal resolution and accuracy. There also exists a need for new small, compact local sensors and instrumentation that are capable of collecting data during transients (e.g., local displacements, temperatures, thermal conductivity, neutron flux, etc.).

  14. Prenatal Diagnosis of Transient Abnormal Myelopoiesis in a Down Syndrome Fetus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gwang Jun; Lee, Eun Sil [Chung-Ang University School of Medicine, Seoul (Korea, Republic of)

    2009-04-15

    We report a case of transient abnormal myelopoiesis in a Down syndrome fetus diagnosed at 28{sup +3} weeks of gestation that rapidly progressed to intrauterine death 10 days later. Fetal hepatosplenomegaly with cerebral ventriculomegaly, although not specific, may be a suggestive finding of Down syndrome with transient abnormal myelopoiesis. Prompt fetal blood sampling for liver function test and chromosomal analysis are mandatory for early detection and management.

  15. Applying Rapid Acquisition Policy Lessons for Defense Innovation

    Science.gov (United States)

    2017-12-21

    import- ing Silicon Valley- style innovation practices to its acquisition process, it is im- portant to assess an organization’s ability to...these efforts. Keywords: defense acquisition, defense procurement, rapid acquisition, de- fense innovation, program management , organizational culture...Device De- feat Organization, JIEDDO, Rapid Equipping Force, REF Silicon Valley- style innovation is a hot topic in the Department of De-fense (DOD). For

  16. A Case Of Transient Ischemic Attack Presenting As Hemichroea

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2013-12-01

    Full Text Available Chorea is defined as; involuntary movements of the distal parts of limbs which have arrhythmic, rapid, bouncing or smooth, simple or complex properties. Choreiform movements occur when putamen, globus pallidus and subthalamic nucleus are affected. Chorea can be observed during the course of metabolic and vascular diseases, neurodegenerative or hereditary diseases. Chorea may be a rare symptom of cerebral hypoperfusion. Transient ischemic attack is an event that occurs in short term characterized by a temporary ischemia of brain. A wide variety of symptoms can be seen depending on the localization of cerebral hypoperfusion. Hemichorea is a very rare finding observed during transient ischemic attacks. In this article hemichorea in a case of symptomatic transient ischemic attack is discussed with relevant literature.

  17. Simulation of Safety and Transient Analysis of a Pressurized Water Reactor using the Personal Computer Transient Analyzer

    Directory of Open Access Journals (Sweden)

    Sunday J. IBRAHIM

    2013-06-01

    Full Text Available Safety and transient analyses of a pressurised water reactor (PWR using the Personal Computer Transient Analyzer (PCTRAN simulator was carried out. The analyses presented a synergistic integration of a numerical model; a full scope high fidelity simulation system which adopted point reactor neutron kinetics model and movable boundary two phase fluid models to simplify the calculation of the program, so it could achieve real-time simulation on a personal computer. Various scenarios of transients and accidents likely to occur at any nuclear power plant were simulated. The simulations investigated the change of signals and parameters vis a vis loss of coolant accident, scram, turbine trip, inadvertent control rod insertion and withdrawal, containment failure, fuel handling accident in auxiliary building and containment, moderator dilution as well as a combination of these parameters. Furthermore, statistical analyses of the PCTRAN results were carried out. PCTRAN results for the loss of coolant accident (LOCA caused a rapid drop in coolant pressure at the rate of 21.8KN/m2/sec triggering a shutdown of the reactor protection system (RPS, while the turbine trip accident showed a rapid drop in total plant power at the rate of 14.3 MWe/sec causing a downtime in the plant. Fuel handling accidents mimic results showed release of radioactive materials in unacceptable doses. This work shows the potential classes of nuclear accidents likely to occur during operation in proposed reactor sites. The simulations are very appropriate in the light of Nigeria’s plan to generate nuclear energy in the region of 1000 MWe from reactors by 2017.

  18. Transient Infrared Emission Spectroscopy

    Science.gov (United States)

    Jones, Roger W.; McClelland, John F.

    1989-12-01

    Transient Infrared Emission Spectroscopy (TIRES) is a new technique that reduces the occurrence of self-absorption in optically thick solid samples so that analytically useful emission spectra may be observed. Conventional emission spectroscopy, in which the sample is held at an elevated, uniform temperature, is practical only for optically thin samples. In thick samples the emission from deep layers of the material is partially absorbed by overlying layers.1 This self-absorption results in emission spectra from most optically thick samples that closely resemble black-body spectra. The characteristic discrete emission bands are severely truncated and altered in shape. TIRES bypasses this difficulty by using a laser to heat only an optically thin surface layer. The increased temperature of the layer is transient since the layer will rapidly cool and thicken by thermal diffusion; hence the emission collection must be correlated with the laser heating. TIRES may be done with both pulsed and cw lasers.2,3 When a pulsed laser is used, the spectrometer sampling must be synchronized with the laser pulsing so that only emission during and immediately after each laser pulse is observed.3 If a cw laser is used, the sample must move rapidly through the beam. The hot, transient layer is then in the beam track on the sample at and immediately behind the beam position, so the spectrometer field of view must be limited to this region near the beam position.2 How much self-absorption the observed emission suffers depends on how thick the heated layer has grown by thermal diffusion when the spectrometer samples the emission. Use of a pulsed laser synchronized with the spectrometer sampling readily permits reduction of the time available for heat diffusion to about 100 acs .3 When a cw laser is used, the heat-diffusion time is controlled by how small the spectrometer field of view is and by how rapidly the sample moves past within this field. Both a very small field of view and a

  19. FFTF fuel pin design procedure verification for transient operation

    International Nuclear Information System (INIS)

    Baars, R.E.

    1975-05-01

    The FFTF design procedures for evaluating fuel pin transient performance are briefly reviewed, and data where available are compared with design procedure predictions. Specifically, burst conditions derived from Fuel Cladding Transient Tester (FCTT) tests and from ANL loss-of-flow tests are compared with burst pressures computed using the design procedure upon which the cladding integrity limit was based. Failure times are predicted using the design procedure for evaluation of rapid reactivity insertion accidents, for five unterminated TREAT experiments in which well characterized fuel failures were deliberately incurred. (U.S.)

  20. Substance P induces rapid and transient membrane blebbing in U373MG cells in a p21-activated kinase-dependent manner.

    Directory of Open Access Journals (Sweden)

    John Meshki

    Full Text Available U373MG astrocytoma cells endogenously express the full-length neurokinin 1 receptor (NK1R. Substance P (SP, the natural ligand for NK1R, triggers rapid and transient membrane blebbing and we report that these morphological changes have different dynamics and intracellular signaling as compared to the changes that we have previously described in HEK293-NK1R cells. In both cell lines, the SP-induced morphological changes are Gq-independent, and they require the Rho, Rho-associated coiled-coil kinase (ROCK signaling pathway. Using confocal microscopy we have demonstrated that tubulin is phosphorylated subsequent to cell stimulation with SP and that tubulin accumulates inside the blebs. Colchicine, a tubulin polymerization inhibitor, blocked SP-induced blebbing in U373MG but not in HEK293-NK1R cells. Although p21-activated kinase (PAK is expressed in both cell lines, SP induced rapid phosphorylation of PAK in U373MG, but failed to phosphorylate PAK in HEK293-NK1R cells. The cell-permeable Rho inhibitor C3 transferase inhibited SP-induced PAK phosphorylation, but the ROCK inhibitor Y27632 had no effect on PAK phosphorylation, suggesting that Rho activates PAK in a ROCK-independent manner. Our study demonstrates that SP triggers rapid changes in cell morphology mediated by distinct intracellular signaling mechanisms in U373MG versus HEK293-NK1R cells.

  1. Test system to simulate transient overpower LMFBR cladding failure

    International Nuclear Information System (INIS)

    Barrus, H.G.; Feigenbutz, L.V.

    1981-01-01

    One of the HEDL programs has the objective to experimentally characterize fuel pin cladding failure due to cladding rupture or ripping. A new test system has been developed which simulates a transient mechanically-loaded fuel pin failure. In this new system the mechanical load is prototypic of a fuel pellet rapidly expanding against the cladding due to various causes such as fuel thermal expansion, fuel melting, and fuel swelling. This new test system is called the Fuel Cladding Mechanical Interaction Mandrel Loading Test (FCMI/MLT). The FCMI/MLT test system and the method used to rupture cladding specimens very rapidly to simulate a transient event are described. Also described is the automatic data acquisition and control system which is required to control the startup, operation and shutdown of the very fast tests, and needed to acquire and store large quantities of data in a short time

  2. Visual investigation of transient fuel behavior under a rapid heating condition

    International Nuclear Information System (INIS)

    Saito, Shinzo

    1981-10-01

    An in-reactor experimental research on fuel behavior under reactivity initiated accident (RIA) conditions is being conducted in the Nuclear Safety Research Reactor (NSRR). The optical system in which a non-browning lens periscope is directly installed in the test section was successfully developed for photographing transient fuel behavior. Several phenomena which had never been revealed before were observed in the slow motion pictures taken in the NSRR experiments which were performed in the water and air environments. As for incipient failure mechanism for an unirradiated fuel rod under RIA conditions, brittle fracture of the cladding during quenching is dominant. However, a split cracking possibly occurs during even red hot state of the cladding. It is considered that the crack is generated by the local internal pressure increase at the specified region blocked up due to the melting of the cladding inner surface. The film boiling is unexpectablly violent specially in the early stage of the transient, and film thickness becomes 5 -- 6 mm at maximum. The observed thick vapor film can not be explained by the conventional theory, but the effect of hydrogen which is produced by Zircaloy-water reaction is reasonably explained to form thick film in the report. The molten fuel was expelled from the cladding in the experiment which was performed in an air environment. The expelled fuel fragmented due to possibly initial motion effect, not mechanical collision effect, because Weber number is smaller than the critical value. (author)

  3. The development of the fuel rod transient performance analysis code FTPAC

    International Nuclear Information System (INIS)

    Han Zhijie; Ji Songtao

    2014-01-01

    Fuel rod behavior, especially the integrity of cladding, played an important role in fuel safety research during reactor transient and hypothetical accidents conditions. In order to study fuel rod performance under transient accidents, FTPAC (Fuel Transient Performance Analysis Code) has been developed for simulating light water reactor fuel rod transient behavior when power or coolant boundary conditions are rapidly changing. It is composed of temperature, mechanical deformation, cladding oxidation and gas pressure model. The assessment was performed by comparing FTPAC code analysis result to experiments data and FRAPTRAN code calculations. Comparison shows that, the FTPAC gives reasonable agreement in temperature, deformation and gas pressure prediction. And the application of slip coefficient is more suitable for simulating the sliding between pellet and cladding when the gap is closed. (authors)

  4. Transient osteoporosis: Not just the hip to worry about

    Directory of Open Access Journals (Sweden)

    Nicola Berman, MD

    2016-12-01

    Full Text Available Transient osteoporosis (TO is a clinical syndrome characterized by joint pain and the presence of bone marrow edema on magnetic resonance imaging (MRI, both of which spontaneously resolve over time. Transient osteoporosis most commonly affects the hip, but also may involve other lower extremity sites. TO likely represents a disorder that may be monoarticular or “migratory” with involvement of two or more lower extremity sites sequentially affected over a number of months. We report on two cases of transient osteoporosis, one involving the knee and one involving the hip, demonstrating the utility of serial bone mineral density measurements at both sites. Additionally, we are able to report on the microarchitectural changes seen at the distal femur on ultra-high resolution (7 T MRI. Case #1 describes a recurrence of transient osteoporosis of the hip three years after a similar presentation at the contralateral hip and highlights the findings of rapidly changing bone mineral density in this clinical syndrome. In contrast to the spine, hip and forearm, peripheral bone density measurements at the knee are rarely reported and to our knowledge Case #2 represents the first report of transient osteoporosis of the knee demonstrating bone density findings similar to that seen in the hip. We postulate that transient osteoporosis of the knee is part of a clinical spectrum most commonly seen in the hip and one that is marked by lower extremity joint pain, bone marrow edema on MRI and transient decreases in bone mineral density all of which spontaneously resolve without sequelae. Keywords: Transient osteoporosis, Transient osteoporosis of the hip, Transient osteoporosis of the knee, Bone marrow edema, High resolution 7 T MRI

  5. Self-similarity in applied superconductivity

    International Nuclear Information System (INIS)

    Dresner, Lawrence

    1981-09-01

    Self-similarity is a descriptive term applying to a family of curves. It means that the family is invariant to a one-parameter group of affine (stretching) transformations. The property of self-similarity has been exploited in a wide variety of problems in applied superconductivity, namely, (i) transient distribution of the current among the filaments of a superconductor during charge-up, (ii) steady distribution of current among the filaments of a superconductor near the current leads, (iii) transient heat transfer in superfluid helium, (iv) transient diffusion in cylindrical geometry (important in studying the growth rate of the reacted layer in A15 materials), (v) thermal expulsion of helium from quenching cable-in-conduit conductors, (vi) eddy current heating of irregular plates by slow, ramped fields, and (vii) the specific heat of type-II superconductors. Most, but not all, of the applications involve differential equations, both ordinary and partial. The novel methods explained in this report should prove of great value in other fields, just as they already have done in applied superconductivity. (author)

  6. A Rapid, Highly Efficient and Economical Method of Agrobacterium-Mediated In planta Transient Transformation in Living Onion Epidermis

    Science.gov (United States)

    Xu, Kedong; Huang, Xiaohui; Wu, Manman; Wang, Yan; Chang, Yunxia; Liu, Kun; Zhang, Ju; Zhang, Yi; Zhang, Fuli; Yi, Liming; Li, Tingting; Wang, Ruiyue; Tan, Guangxuan; Li, Chengwei

    2014-01-01

    Transient transformation is simpler, more efficient and economical in analyzing protein subcellular localization than stable transformation. Fluorescent fusion proteins were often used in transient transformation to follow the in vivo behavior of proteins. Onion epidermis, which has large, living and transparent cells in a monolayer, is suitable to visualize fluorescent fusion proteins. The often used transient transformation methods included particle bombardment, protoplast transfection and Agrobacterium-mediated transformation. Particle bombardment in onion epidermis was successfully established, however, it was expensive, biolistic equipment dependent and with low transformation efficiency. We developed a highly efficient in planta transient transformation method in onion epidermis by using a special agroinfiltration method, which could be fulfilled within 5 days from the pretreatment of onion bulb to the best time-point for analyzing gene expression. The transformation conditions were optimized to achieve 43.87% transformation efficiency in living onion epidermis. The developed method has advantages in cost, time-consuming, equipment dependency and transformation efficiency in contrast with those methods of particle bombardment in onion epidermal cells, protoplast transfection and Agrobacterium-mediated transient transformation in leaf epidermal cells of other plants. It will facilitate the analysis of protein subcellular localization on a large scale. PMID:24416168

  7. Partial discharge transients: The field theoretical approach

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C

    1998-01-01

    Up until the mid-1980s the theory of partial discharge transients was essentially static. This situation had arisen because of the fixation with the concept of void capacitance and the use of circuit theory to address what is in essence a field problem. Pedersen rejected this approach and instead...... began to apply field theory to the problem of partial discharge transients. In the present paper, the contributions of Pedersen using the field theoretical approach will be reviewed and discussed....

  8. Improvement of the transient stability using SFCL in Korean power systems

    International Nuclear Information System (INIS)

    Hwang, Intae; Lee, Seung Ryul; Seo, Sangsoo; Yoon, Jaeyoung; Kim, Chul-Hwan

    2013-01-01

    Highlights: •In Korea, the Special Protection System is applied for protecting the power system. •Hybrid SFCL is protecting the power system from viewpoint of the transient stability. •Basic hybrid SFCL system cannot recover during the auto-reclosing operation. •This paper performs analysis of transient stability using the novel hybrid SFCL. -- Abstract: This paper proposed a novel hybrid SFCL system for the enhancement of the transient stability in Korean power transmission system with auto-reclosing operation. The proposed SFCL system has an operation mechanism that the current limiting impedance is eliminated from the power system in a fault clearing time for the enhancement of the transient stability. Also, the system can cover the auto-reclosing operation of the transmission power system. This study analyzed an improvement of the special protection system by applying the proposed SFCL system to real power system in Korea

  9. Transient fuel melting

    International Nuclear Information System (INIS)

    Roche, L.; Schmitz, F.

    1982-10-01

    The observation of micrographic documents from fuel after a CABRI test leads to postulate a specific mode of transient fuel melting during a rapid nuclear power excursion. When reaching the melt threshold, the bands which are characteristic for the solid state are broken statistically over a macroscopic region. The time of maintaining the fuel at the critical enthalpy level between solid and liquid is too short to lead to a phase separation. A significant life-time (approximately 1 second) of this intermediate ''unsolide'' state would have consequences on the variation of physical properties linked to the phase transition solid/liquid: viscosity, specific volume and (for the irradiated fuel) fission gas release [fr

  10. A Protoplast Transient Expression System to Enable Molecular, Cellular, and Functional Studies in Phalaenopsis orchids

    Directory of Open Access Journals (Sweden)

    Hsiang-Yin Lin

    2018-06-01

    Full Text Available The enigmatic nature of the specialized developmental programs of orchids has fascinated plant biologists for centuries. The recent releases of orchid genomes indicate that orchids possess new gene families and family expansions and contractions to regulate a diverse suite of developmental processes. However, the extremely long orchid life cycle and lack of molecular toolkit have hampered the advancement of orchid biology research. To overcome the technical difficulties and establish a platform for rapid gene regulation studies, in this study, we developed an efficient protoplast isolation and transient expression system for Phalaenopsis aphrodite. This protocol was successfully applied to protein subcellular localization and protein–protein interaction studies. Moreover, it was confirmed to be useful in delineating the PaE2F/PaDP-dependent cell cycle pathway and studying auxin response. In summary, the established orchid protoplast transient expression system provides a means to functionally characterize orchid genes at the molecular level allowing assessment of transcriptome responses to transgene expression and widening the scope of molecular studies in orchids.

  11. THE EFFECTS OF TRANSIENTS ON PHOTOSPHERIC AND CHROMOSPHERIC POWER DISTRIBUTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Samanta, T.; Banerjee, D.; Pant, V. [Indian Institute of Astrophysics, Koramangala, Bangalore 560034 (India); Henriques, V. M. J.; Prasad, S. Krishna; Mathioudakis, M.; Jess, D., E-mail: tsamanta@iiap.res.in, E-mail: v.henriques@qub.ac.uk [Astrophysics Research Centre, School of Mathematics and Physics, Queen’s University Belfast, Belfast BT7 1NN (United Kingdom)

    2016-09-01

    We have observed a quiet-Sun region with the Swedish 1 m Solar Telescope equipped with the CRISP Imaging SpectroPolarimeter. High-resolution, high-cadence, H α line scanning images were taken to observe different layers of the solar atmosphere from the photosphere to upper chromosphere. We study the distribution of power in different period bands at different heights. Power maps of the upper photosphere and the lower chromosphere show suppressed power surrounding the magnetic-network elements, known as “magnetic shadows.” These also show enhanced power close to the photosphere, traditionally referred to as “power halos.” The interaction between acoustic waves and inclined magnetic fields is generally believed to be responsible for these two effects. In this study we explore whether small-scale transients can influence the distribution of power at different heights. We show that the presence of transients, like mottles, Rapid Blueshifted Excursions (RBEs), and Rapid Redshifted Excursions (RREs), can strongly influence the power maps. The short and finite lifetime of these events strongly affects all power maps, potentially influencing the observed power distribution. We show that Doppler-shifted transients like RBEs and RREs that occur ubiquitously can have a dominant effect on the formation of the power halos in the quiet Sun. For magnetic shadows, transients like mottles do not seem to have a significant effect on the power suppression around 3 minutes, and wave interaction may play a key role here. Our high-cadence observations reveal that flows, waves, and shocks manifest in the presence of magnetic fields to form a nonlinear magnetohydrodynamic system.

  12. Transient radiative transfer in a scattering slab considering polarization.

    Science.gov (United States)

    Yi, Hongliang; Ben, Xun; Tan, Heping

    2013-11-04

    The characteristics of the transient and polarization must be considered for a complete and correct description of short-pulse laser transfer in a scattering medium. A Monte Carlo (MC) method combined with a time shift and superposition principle is developed to simulate transient vector (polarized) radiative transfer in a scattering medium. The transient vector radiative transfer matrix (TVRTM) is defined to describe the transient polarization behavior of short-pulse laser propagating in the scattering medium. According to the definition of reflectivity, a new criterion of reflection at Fresnel surface is presented. In order to improve the computational efficiency and accuracy, a time shift and superposition principle is applied to the MC model for transient vector radiative transfer. The results for transient scalar radiative transfer and steady-state vector radiative transfer are compared with those in published literatures, respectively, and an excellent agreement between them is observed, which validates the correctness of the present model. Finally, transient radiative transfer is simulated considering the polarization effect of short-pulse laser in a scattering medium, and the distributions of Stokes vector in angular and temporal space are presented.

  13. Do Magnetic Fields drive high-energy explosive transients?

    OpenAIRE

    Mundell, Carole

    2017-01-01

    I will review the current state-of-the-art in real-time, rapid response optical imaging and polarimetric followup of transient sources such as Gamma Ray Bursts. I will interpret current results within the context of the external shock model and present predictions for future mm- and cm-wave radio observatories. Recent observational results from new radio pilot studies will also be presented.

  14. Do Magnetic Fields Drive High-Energy Explosive Transients?

    Science.gov (United States)

    Mundell, Carole

    2017-10-01

    I will review the current state-of-the-art in real-time, rapid response optical imaging and polarimetric followup of transient sources such as Gamma Ray Bursts. I will interpret current results within the context of the external shock model and present predictions for future mm- and cm-wave radio observatories. Recent observational results from new radio pilot studies will also be presented.

  15. Boom or bust? A comparative analysis of transient population dynamics in plants

    DEFF Research Database (Denmark)

    Stott, Iain; Franco, Miguel; Carslake, David

    2010-01-01

    researchers as further possible effectors of complicated dynamics. Previously published methods of transient analysis have tended to require knowledge of initial population structure. However, this has been overcome by the recent development of the parametric Kreiss bound (which describes how large...... a population must become before reaching its maximum possible transient amplification following a disturbance) and the extension of this and other transient indices to simultaneously describe both amplified and attenuated transient dynamics. We apply the Kreiss bound and other transient indices to a data base...... worrying artefact of basic model parameterization. Synthesis. Transient indices describe how big or how small plant populations can get, en route to long-term stable rates of increase or decline. The patterns we found in the potential for transient dynamics, across many species of plants, suggest...

  16. Modelling transient energy release from molten fuel coolant interaction debris

    International Nuclear Information System (INIS)

    Fletcher, D.F.

    1984-05-01

    A simple model of transient energy release in a Molten Fuel Coolant Interaction is presented. A distributed heat transfer model is used to examine the effect of heat transfer coefficient, time available for rapid energy heat transfer and particle size on transient energy release. The debris is assumed to have an Upper Limit Lognormal distribution. Model predictions are compared with results from the SUW series of experiments which used thermite-generated uranium dioxide molybdenum melts released below the surface of a pool of water. Uncertainties in the physical principles involved in the calculation of energy transfer rates are discussed. (author)

  17. Apparatus and method for transient thermal infrared emission spectrometry

    Science.gov (United States)

    McClelland, John F.; Jones, Roger W.

    1991-12-24

    A method and apparatus for enabling analysis of a solid material (16, 42) by applying energy from an energy source (20, 70) top a surface region of the solid material sufficient to cause transient heating in a thin surface layer portion of the solid material (16, 42) so as to enable transient thermal emission of infrared radiation from the thin surface layer portion, and by detecting with a spectrometer/detector (28, 58) substantially only the transient thermal emission of infrared radiation from the thin surface layer portion of the solid material. The detected transient thermal emission of infrared radiation is sufficiently free of self-absorption by the solid material of emitted infrared radiation, so as to be indicative of characteristics relating to molecular composition of the solid material.

  18. Transient fault tolerant control for vehicle brake-by-wire systems

    International Nuclear Information System (INIS)

    Huang, Shuang; Zhou, Chunjie; Yang, Lili; Qin, Yuanqing; Huang, Xiongfeng; Hu, Bowen

    2016-01-01

    Brake-by-wire (BBW) systems that have no mechanical linkage between the brake pedal and the brake mechanism are expected to improve vehicle safety through better braking capability. However, transient faults in BBW systems can cause dangerous driving situations. Most existing research in this area focuses on the brake control mechanism, but very few studies try to solve the problem associated with transient fault propagation and evolution in the brake control system hierarchy. In this paper, a hierarchical transient fault tolerant scheme with embedded intelligence and resilient coordination for BBW system is proposed based on the analysis of transient fault propagation characteristics. In this scheme, most transient faults are tackled rapidly by a signature-based detection method at the node level, and the remaining transient faults, which cannot be detected directly at the node level and could degrade the system performance through fault propagation and evolution, are detected and recovered through function and structure models at the system level. To jointly accommodate these BBW transient faults at the system level, a sliding mode control algorithm and a task reallocation strategy are designed. A simulation platform based on Architecture Analysis and Design Language (AADL) is established to evaluate the task reallocation strategy, and a hardware-in-the-loop simulation is carried out to validate the proposed scheme systematically. Experimental results show the effectiveness of this new approach to BBW systems. - Highlights: • We propose a hierarchical transient fault tolerant scheme for BBW systems. • A sliding mode algorithm and a task strategy are designed to tackle transient fault. • The effectiveness of the scheme is verified in both simulation and HIL environments.

  19. Transient analysis of air-water two-phase flow in channels and bends

    International Nuclear Information System (INIS)

    Khan, H.J.; Ye, W.; Pertmer, G.A.

    1992-01-01

    The algorithm used in this paper is the Newton Block Gauss Seidel method, which has been applied to both simple and complex flow conditions in two-phase flow. This paper contains a description of difference techniques and an iterative solution algorithm that is used to solve the field and constitutive equations of the two-fluid model. In practice, this solution procedure has been proven to be stable and capable of generating solutions in problems where other schemes have failed. The method converges rapidly for reasonable error tolerances and is easily extended to three-dimensional geometries. Using air-water as the two-phase medium, transient flow behavior in several geometries of interest are shown. Flow through a vertical channel with flow obstruction, large U bends, and 90-deg bends are being demonstrated with variation of inlet void fraction and slip ratio. Significant changes in the velocity and void distribution profiles have been observed. Various regions of flow recirculation are obtained in the flow domain for each phase. The phasic velocity and void distributions are dominated by gravity-induced phase separation causing air to accumulate in the upper region. The influence of inlet slip ratio and interfacial momentum transfer on the transient flow profile has been demonstrated in detail

  20. Scanning ion deep level transient spectroscopy: I. Theory

    International Nuclear Information System (INIS)

    Laird, J S; Jagadish, C; Jamieson, D N; Legge, G J F

    2006-01-01

    Theoretical aspects of a new technique for the MeV ion microbeam are described in detail for the first time. The basis of the technique, termed scanning ion deep level transient spectroscopy (SIDLTS), is the imaging of defect distributions within semiconductor devices. The principles of SIDLTS are similar to those behind other deep level transient spectroscopy (DLTS) techniques with the main difference stemming from the injection of carriers into traps using the localized energy-loss of a focused MeV ion beam. Energy-loss of an MeV ion generates an electron-hole pair plasma, providing the equivalent of a DLTS trap filling pulse with a duration which depends on space-charge screening of the applied electric field and ambipolar erosion of the plasma for short ranging ions. Some nanoseconds later, the detrapping current transient is monitored as a charge transient. Scanning the beam in conjunction with transient analysis allows the imaging of defect levels. As with DLTS, the temperature dependence of the transient can be used to extract trap activation levels. In this, the first of a two-part paper, we introduce the various stages of corner capture and derive a simple expression for the observed charge transient. The second paper will illustrate the technique on a MeV ion implanted Au-Si Schottky junction

  1. International standard problem (ISP) No. 43 Rapid boron-dilution transient tests for code verification. Comparison report

    International Nuclear Information System (INIS)

    2001-03-01

    International Standard Problem No. 43 (ISP 43) addresses the nuclear industries present capabilities of simulating fluid dynamics aspects of a subset of rapid boron dilution transients. Specifically, the exercise focuses on the sequence involving the transport of a boron-dilute slug through the actuation of a pump. The slug is formed on the primary side of the steam generator as a consequence of in interfacing system leak from the secondary un-borated coolant. Experimental data was collected using the University of Maryland 2 x 4 Thermalhydraulic Loop (UM 2 x 4 Loop) and the Boron-mixing Visualization Facility. Two blind test series were proposed during the first workshop (October 1998) and refined using participant input. The first series, test series A, deals with the injection of a front, i.e., a single interface between borated and dilute fluids. The second blind series, test series B, is the more realistic injection of a slug, i.e., a dilute fluid volume preceded and followed by the borated coolant of the primary system. Data are collected in the UM 2 x 4 Loop and refined details are obtained from the Visualization Facility, which represents a replica of the Loop.s vessel downcomer. In the Loop experimental program, the dilute volume is simulated by cold water and the borated primary coolant is simulated by hot water. The Visualization Facility uses dye to mark the diluted front or slug. The measured boundary conditions for both test series include the initial temperature of the primary system, the front/slug injection flowrate and temperature, and the pressure drop across the core. Temperature data is collected at 185 thermocouple positions in the downcomer and 38 positions in the lower plenum. The advancement of the front/slug through the system is monitored at discrete horizontal levels that contain the thermocouples. The performance of codes is measured relative to a set of figures of merit. During the first workshop, the principal figure of merit was

  2. Newborn hearing screening with transient evoked otoacoustic emissions and automatic auditory brainstem response

    Directory of Open Access Journals (Sweden)

    Renata Mota Mamede de Carvallo

    2008-09-01

    Full Text Available Objective: The aim of the present investigation was to check Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response tests applied together in regular nurseries and Newborn Intensive Care Units (NICU, as well as to describe and compare the results obtained in both groups. Methods: We tested 150 newborns from regular nurseries and 70 from NICU. Rresults: The newborn hearing screening results using Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response tests could be applied to all babies. The “pass” result for the group of babies from the nursery was 94.7% using Transient Evoked Otoacoustic Emissions and 96% using Automatic Auditory Brainstem Response. The newborn intensive care unit group obtained 87.1% on Transient Evoked Otoacoustic Emissions and 80% on the Automatic Auditory Brainstem Response, and there was no statistical difference between the procedures when the groups were evaluated individually. However, comparing the groups, Transient Evoked Otoacoustic Emissions were presented in 94.7% of the nursery babies and in 87.1% in the group from the newborn intensive care unit. Considering the Automatic Auditory Brainstem Response, we found 96 and 87%, respectively. Cconclusions: Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response had similar “pass” and “fail” results when the procedures were applied to neonates from the regular nursery, and the combined tests were more precise to detect hearing impairment in the newborn intensive care unit babies.

  3. Performance enhancement of microbial fuel cell by applying transient-state regulation

    International Nuclear Information System (INIS)

    Liang, Peng; Zhang, Changyong; Jiang, Yong; Bian, Yanhong; Zhang, Helan; Sun, Xueliang; Yang, Xufei; Zhang, Xiaoyuan; Huang, Xia

    2017-01-01

    Highlights: • MFC was operated with transient-state regulation to enhance its performance. • Effects of the TSR parameters on MFC performance were thoroughly investigated. • Long-term operation of MFC in TSR mode allowed 32.7% higher power production. • Anode capacitance helped reduce the MFC’s internal impedance in the TSR mode. - Abstract: A binder-free, pseudocapacitive anode was fabricated by coating reduced graphene oxide (rGO) and manganese oxide (MnO_2) nanoparticles on stainless steel fibre felt (SS). Microbial fuel cell (MFC) equipped with this novel anode yielded a maximum power density of 1045 mW m"−"2, 20 times higher than that of a similar MFC with a bare SS anode (46 mW m"−"2). Transient-state regulation (TSR) was implemented to further improve the MFC’s power generation. The optimal TSR duty cycle ranged from 67% to 95%, and the MFC’s power density increased with TSR frequency. A maximum power density output of 1238 mW m"−"2 was achieved at the TSR duty cycle of 75% and the frequency of 1 Hz, 18.4% greater than that obtained from the steady state operation. The TSR mode delivered better MFC performance especially when the external resistance was small. Long-term operation tests revealed that the current density and power density yielded in the TSR mode were on average 15.0% and 32.7% greater than those in the steady state mode, respectively. The TSR mode was believed to reduce the internal resistance of the MFC while enhance substrate mass transfer and electron transfer within the anode matrix, thereby improving the MFC performance.

  4. Initial Implementation of Transient VERA-CS

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, Andrew [Univ. of Michigan, Ann Arbor, MI (United States); Kochunas, Brendan [Univ. of Michigan, Ann Arbor, MI (United States); Salko, Robert [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wysocki, Aaron J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-11-01

    In this milestone the capabilities of both CTF and MPACT were extended to perform coupled transient calculations. This required several small changes in MPACT to setup the problems correctly, perform the edits correctly, and call the appropriate CTF interfaces in the right order. For CTF, revisions and corrections to the transient timestepping algorithm were made, as well as the addition of a new interface subroutine to allow MPACT to drive CTF at each timestep. With the modifications completed, the initial coupled capability was demonstrated on some problems used for code verification, a hypothetical small mini-core, and a Watts Bar demonstration problem. For each of these cases the results showed good agreement with the previous MPACT internal TH feedback model that relied on a simplified fuel heat conduction model and simplified coolant treatment. After the pulse the results are notably different as expected, where the effects of convection of heat to the coolant can be observed. Areas for future work were discussed, including assessment and development of the CTF dynamic fuel deformation and gap conductance models, addition of suitable transient boiling and CHF models for the rapid heating and cooling rates seen in RIAs, additional validation and demonstration work, and areas for improvement to the code input and output capabilities.

  5. Transient eddy feedback and low-frequency variability

    International Nuclear Information System (INIS)

    Robinson, W.A.

    1994-01-01

    Superposed on any externally driven secular climatic change are fluctuations that arise from the internal nonlinear dynamics of the climate system. These internally generated variations may involve interactions between the atmosphere and the ocean, as in the case of El Nino, or they may arise from the dynamics of the atmosphere alone. Here we discuss the dynamics of interactions between transient eddies and lower-frequency motions in the atmosphere. The interactions between more transient and more persistent motions can be divided into two types. Nonlinear interactions among the transient motions can act as an essentially random source of low-frequency motion. The idea that the low-frequencies respond in a linear way to stochastic forcing from higher frequencies has been applied to the generation of planetary waves and to the forcing of changes in global angular momentum. In addition to stochastic coupling, there are systematic interactions, denoted feedbacks, through which the persistent motions modulate their own forcing by the transient eddies. This paper discusses the dynamics of these feedbacks

  6. A faster reactor transient analysis methodology for PCs

    International Nuclear Information System (INIS)

    Ott, K.O.

    1991-10-01

    The simplified ANL model for LMR transient analysis, in which point kinetics as well as lumped descriptions of the heat transfer equations in all components are applied, is converted from a differential into an integral formulation. All differential balance equations are implicitly solved in terms of convolution integrals. The prompt jump approximation is applied as the strong negative feedback effectively keeps the net reactivity well below prompt critical. After implicit finite differencing of the convolution integrals, the kinetics equation assumes the form of a quadratic equation, the ''quadratic dynamics equation.'' This model forms the basis for GW-BASIC program, LTC, for LMR Transient Calculation program, which can effectively be run on a PC. The GW-BASIC version of the LTC program is described in detail in Volume 2 of this report

  7. Transient plant transformation mediated by Agrobacterium tumefaciens: Principles, methods and applications.

    Science.gov (United States)

    Krenek, Pavel; Samajova, Olga; Luptovciak, Ivan; Doskocilova, Anna; Komis, George; Samaj, Jozef

    2015-11-01

    Agrobacterium tumefaciens is widely used as a versatile tool for development of stably transformed model plants and crops. However, the development of Agrobacterium based transient plant transformation methods attracted substantial attention in recent years. Transient transformation methods offer several applications advancing stable transformations such as rapid and scalable recombinant protein production and in planta functional genomics studies. Herein, we highlight Agrobacterium and plant genetics factors affecting transfer of T-DNA from Agrobacterium into the plant cell nucleus and subsequent transient transgene expression. We also review recent methods concerning Agrobacterium mediated transient transformation of model plants and crops and outline key physical, physiological and genetic factors leading to their successful establishment. Of interest are especially Agrobacterium based reverse genetics studies in economically important crops relying on use of RNA interference (RNAi) or virus-induced gene silencing (VIGS) technology. The applications of Agrobacterium based transient plant transformation technology in biotech industry are presented in thorough detail. These involve production of recombinant proteins (plantibodies, vaccines and therapeutics) and effectoromics-assisted breeding of late blight resistance in potato. In addition, we also discuss biotechnological potential of recombinant GFP technology and present own examples of successful Agrobacterium mediated transient plant transformations. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Switching transients in a superconducting coil

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1983-01-01

    A study is made of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to performance tests on the MFTF Yin-yang coils. It is found that the breaker opening time is the critical factor in determining the size and shape of the transient. Instantaneous opening of the breaker causes a lightly damped transient with large amplitude voltages to ground. Increasing the opening time causes the transient to become a monopulse of decreasing amplitude. The voltages at the external terminals are determined by the parameters of the external circuit. For fast opening times the frequency depends on the dump resistor inductance, the circuit capacitance, and the amplitude on the coil current. For slower openings the dump resistor inductance and the current determine the amplitude of the voltage to ground at the terminals. Voltages to ground are less in the interior of the coil, where transients related to the parameters of the coil itself are observed

  9. Rapid ultrasound-induced transient-liquid-phase bonding of Al-50Si alloys with Zn interlayer in air for electrical packaging application.

    Science.gov (United States)

    Wang, Qian; Chen, Xiaoguang; Zhu, Lin; Yan, Jiuchun; Lai, Zhiwei; Zhao, Pizhi; Bao, Juncheng; Lv, Guicai; You, Chen; Zhou, Xiaoyu; Zhang, Jian; Li, Yuntao

    2017-01-01

    Al-50Si alloys were joined by rapid ultrasound-induced transient-liquid-phase bonding method using Zn foil as interlayer at 390°C in air, below the melt point of interlayer. The fracture of oxide films along the edge of Si particles led to contact and inter-diffusion between aluminum substrate and Zn interlayer, and liquefied Zn-Al alloys were developed. The width of Zn-Al alloys gradually decreased with increasing the ultrasonic vibration time due to liquid squeezing out and accelerated diffusion. A stage of isothermal solidification existed, and the completion time was significantly shortened. In the liquid metal, the acoustic streaming and ultrasonic cavitations were induced. As the process developed, much more Si particles, which were particulate-reinforced phases of Al-50Si, gradually migrated to the center of soldering seam. The highest average shear strength of joints reached to 94.2MPa, and the fracture mainly occurred at the base metal. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Application of statistical method for FBR plant transient computation

    International Nuclear Information System (INIS)

    Kikuchi, Norihiro; Mochizuki, Hiroyasu

    2014-01-01

    Highlights: • A statistical method with a large trial number up to 10,000 is applied to the plant system analysis. • A turbine trip test conducted at the “Monju” reactor is selected as a plant transient. • A reduction method of trial numbers is discussed. • The result with reduced trial number can express the base regions of the computed distribution. -- Abstract: It is obvious that design tolerances, errors included in operation, and statistical errors in empirical correlations effect on the transient behavior. The purpose of the present study is to apply above mentioned statistical errors to a plant system computation in order to evaluate the statistical distribution contained in the transient evolution. A selected computation case is the turbine trip test conducted at 40% electric power of the prototype fast reactor “Monju”. All of the heat transport systems of “Monju” are modeled with the NETFLOW++ system code which has been validated using the plant transient tests of the experimental fast reactor Joyo, and “Monju”. The effects of parameters on upper plenum temperature are confirmed by sensitivity analyses, and dominant parameters are chosen. The statistical errors are applied to each computation deck by using a pseudorandom number and the Monte-Carlo method. The dSFMT (Double precision SIMD-oriented Fast Mersenne Twister) that is developed version of Mersenne Twister (MT), is adopted as the pseudorandom number generator. In the present study, uniform random numbers are generated by dSFMT, and these random numbers are transformed to the normal distribution by the Box–Muller method. Ten thousands of different computations are performed at once. In every computation case, the steady calculation is performed for 12,000 s, and transient calculation is performed for 4000 s. In the purpose of the present statistical computation, it is important that the base regions of distribution functions should be calculated precisely. A large number of

  11. Study of transient burnout under flow reduction condition

    International Nuclear Information System (INIS)

    Iwamura, Takamichi

    1986-09-01

    Transient burnout characteristics of a fuel rod under a rapid flow reduction condition of a light water reactor were experimentally and analytically studied. The test sections were uniformly heated vertical tube and annulus with the heated length of 800 mm. Test pressures ranged 0.5 ∼ 3.9 MPa, heat fluxes 2,160 ∼ 3,860 KW/m 2 , and flow reduction rates 0.44 ∼ 770 %/s. The local flow condition during flow reduction transients were calculated with a separate flow model. The two-fluid/three-field thermal-hydraulic code, COBRA/TRAC, was also used to investigate the liquid film behavior on the heated surface. The major results obtained in the present study are as follows: The onset of burnout under a rapid flow reduction condition was caused by a liquid film dryout on the heated surface. With increasing flow reduction rate beyond a threshold, the burnout mass velocity at the inlet became lower than the steady-state burnout mass velocity. This is explained by the fact that the vapor flow rate continues to increase due to the delay of boiling boundary movement and the resultant high vapor velocity sustains the liquid film flow after the inlet flow rate reaches the steady-state burnout flow rate. The ratio of inlet burnout mass velocities between flow reduction transient and steady-state became smaller with increasing system pressure because of the lower vapor velocity due to the lower vapor specific volume. Flow reduction burnout occurred when the outlet quality agreed with the steady-state burnout quality within 10 %, suggesting that the local condition burnout model can be used for flow reduction transients. Based on this model, a method to predict the time to burnout under a flow reduction condition in a uniformly heated tube was developed. The calculated times to burnout agreed well with some experimental results obtained by the Author, Cumo et al., and Moxon et al. (author)

  12. Control of operational transients in power reactors - Methodology

    International Nuclear Information System (INIS)

    Vukovic, D.

    1983-01-01

    By introducing the nuclear power stations in the electric power system, questions of their possibilities to satisfy system's demand arise. Control of operational transients (temperature and Xe 135 ) in power reactors by determining the optimal control rod strategy is given. Ti optimize the Xe 135 transients, the Pantryagin theorem of optimal processes is applied. For solving three dimensional, two-group diffusion equations the heterogeneous Feinberg-Galanin method with axial flux harmonics is adopted. An application of this formalism to three-dimensional, finite cylindrical pressurised water reactor radially reflected is presented. (author)

  13. PC operated acoustic transient spectroscopy of deep levels in MIS structures

    International Nuclear Information System (INIS)

    Bury, P.; Jamnicky, I.

    1996-01-01

    A new version of acoustic deep-level transient spectroscopy is presented to study the traps at the insulator-semiconductor interface. The acoustic deep-level transient spectroscopy uses an acoustoelectric response signal produced by the MIS structure interface when a longitudinal acoustic wave propagates through a structure. The acoustoelectric response signal is extremely sensitive to external conditions of the structure and reflects any changes in the charge distribution, connected also with charged traps. In comparison with previous version of acoustic deep-level transient spectroscopy that closely coincides with the principle of the original deep-level transient spectroscopy technique, the present technique is based on the computer-evaluated isothermal transients and represents an improved, more efficient and time saving technique. Many tests on the software used for calculation as well as on experimental setup have been performed. The improved acoustic deep-level transient spectroscopy method has been applied for the Si(p) MIS structures. The deep-level parameters as activation energy and capture cross-section have been determined. (authors)

  14. MOSFiT: Modular Open Source Fitter for Transients

    Science.gov (United States)

    Guillochon, James; Nicholl, Matt; Villar, V. Ashley; Mockler, Brenna; Narayan, Gautham; Mandel, Kaisey S.; Berger, Edo; Williams, Peter K. G.

    2018-05-01

    Much of the progress made in time-domain astronomy is accomplished by relating observational multiwavelength time-series data to models derived from our understanding of physical laws. This goal is typically accomplished by dividing the task in two: collecting data (observing), and constructing models to represent that data (theorizing). Owing to the natural tendency for specialization, a disconnect can develop between the best available theories and the best available data, potentially delaying advances in our understanding new classes of transients. We introduce MOSFiT: the Modular Open Source Fitter for Transients, a Python-based package that downloads transient data sets from open online catalogs (e.g., the Open Supernova Catalog), generates Monte Carlo ensembles of semi-analytical light-curve fits to those data sets and their associated Bayesian parameter posteriors, and optionally delivers the fitting results back to those same catalogs to make them available to the rest of the community. MOSFiT is designed to help bridge the gap between observations and theory in time-domain astronomy; in addition to making the application of existing models and creation of new models as simple as possible, MOSFiT yields statistically robust predictions for transient characteristics, with a standard output format that includes all the setup information necessary to reproduce a given result. As large-scale surveys such as that conducted with the Large Synoptic Survey Telescope (LSST), discover entirely new classes of transients, tools such as MOSFiT will be critical for enabling rapid comparison of models against data in statistically consistent, reproducible, and scientifically beneficial ways.

  15. Rapid Transient Fault Insertion in Large Digital Systems

    NARCIS (Netherlands)

    Rohani, A.; Kerkhoff, Hans G.

    This paper presents a technique for rapidtransientfault injection, regarding the CPU time, to perform simulation-based fault-injection in complex System-on-Chip Systems (SoCs). The proposed approach can be applied to complex circuits, as it is not required to modify the top-level modules of a

  16. The excess radio background and fast radio transients

    International Nuclear Information System (INIS)

    Kehayias, John; Kephart, Thomas W.; Weiler, Thomas J.

    2015-01-01

    In the last few years ARCADE 2, combined with older experiments, has detected an additional radio background, measured as a temperature and ranging in frequency from 22 MHz to 10 GHz, not accounted for by known radio sources and the cosmic microwave background. One type of source which has not been considered in the radio background is that of fast transients (those with event times much less than the observing time). We present a simple estimate, and a more detailed calculation, for the contribution of radio transients to the diffuse background. As a timely example, we estimate the contribution from the recently-discovered fast radio bursts (FRBs). Although their contribution is likely 6 or 7 orders of magnitude too small (though there are large uncertainties in FRB parameters) to account for the ARCADE 2 excess, our development is general and so can be applied to any fast transient sources, discovered or yet to be discovered. We estimate parameter values necessary for transient sources to noticeably contribute to the radio background

  17. Large-timestep techniques for particle-in-cell simulation of systems with applied fields that vary rapidly in space

    International Nuclear Information System (INIS)

    Friedman, A.; Grote, D.P.

    1996-10-01

    Under conditions which arise commonly in space-charge-dominated beam applications, the applied focusing, bending, and accelerating fields vary rapidly with axial position, while the self-fields (which are, on average, comparable in strength to the applied fields) vary smoothly. In such cases it is desirable to employ timesteps which advance the particles over distances greater than the characteristic scales over which the applied fields vary. Several related concepts are potentially applicable: sub-cycling of the particle advance relative to the field solution, a higher-order time-advance algorithm, force-averaging by integration along approximate orbits, and orbit-averaging. We report on our investigations into the utility of such techniques for systems typical of those encountered in accelerator studies for heavy-ion beam-driven inertial fusion

  18. Laser spectroscopy and dynamics of transient species

    Energy Technology Data Exchange (ETDEWEB)

    Clouthier, D.J. [Univ. of Kentucky, Lexington (United States)

    1993-12-01

    The goal of this program is to study the vibrational and electronic spectra and excited state dynamics of a number of transient sulfur and oxygen species. A variety of supersonic jet techniques, as well as high resolution FT-IR and intracavity dye laser spectroscopy, have been applied to these studies.

  19. Kinetics of transient electroluminescence in organic light emitting diodes

    Science.gov (United States)

    Shukla, Manju; Kumar, Pankaj; Chand, Suresh; Brahme, Nameeta; Kher, R. S.; Khokhar, M. S. K.

    2008-08-01

    Mathematical simulation on the rise and decay kinetics of transient electroluminescence (EL) in organic light emitting diodes (OLEDs) is presented. The transient EL is studied with respect to a step voltage pulse. While rising, for lower values of time, the EL intensity shows a quadratic dependence on (t - tdel), where tdel is the time delay observed in the onset of EL, and finally attains saturation at a sufficiently large time. When the applied voltage is switched off, the initial EL decay shows an exponential dependence on (t - tdec), where tdec is the time when the voltage is switched off. The simulated results are compared with the transient EL performance of a bilayer OLED based on small molecular bis(2-methyl 8-hydroxyquinoline)(triphenyl siloxy) aluminium (SAlq). Transient EL studies have been carried out at different voltage pulse amplitudes. The simulated results show good agreement with experimental data. Using these simulated results the lifetime of the excitons in SAlq has also been calculated.

  20. Kinetics of transient electroluminescence in organic light emitting diodes

    International Nuclear Information System (INIS)

    Shukla, Manju; Brahme, Nameeta; Kumar, Pankaj; Chand, Suresh; Kher, R S; Khokhar, M S K

    2008-01-01

    Mathematical simulation on the rise and decay kinetics of transient electroluminescence (EL) in organic light emitting diodes (OLEDs) is presented. The transient EL is studied with respect to a step voltage pulse. While rising, for lower values of time, the EL intensity shows a quadratic dependence on (t - t del ), where t del is the time delay observed in the onset of EL, and finally attains saturation at a sufficiently large time. When the applied voltage is switched off, the initial EL decay shows an exponential dependence on (t - t dec ), where t dec is the time when the voltage is switched off. The simulated results are compared with the transient EL performance of a bilayer OLED based on small molecular bis(2-methyl 8-hydroxyquinoline)(triphenyl siloxy) aluminium (SAlq). Transient EL studies have been carried out at different voltage pulse amplitudes. The simulated results show good agreement with experimental data. Using these simulated results the lifetime of the excitons in SAlq has also been calculated

  1. Optimisation of a combined transient-ion-drift/rapid thermal annealing process for copper detection in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Belayachi, A.; Heiser, T.; Schunck, J.P.; Bourdais, S.; Bloechl, P.; Huber, A.; Kempf, A

    2003-09-15

    The transient ion drift (TID) technique has been recently proposed for copper trace detection in silicon. Cu atoms may be present either in the vicinity of the Si surface or within the volume. In the latter case they are either gathered at secondary defects or form precipitates believed to be silicides. In order to become detectable by TID Cu atoms must be put into the highly mobile interstitial state. Depending on the initial configuration of the Cu/Si system different physical mechanisms may enable Cu atoms to become 'TID active'. In this work we study the Cu activation process using rapid thermal processing (RTP) in an attempt to minimise the thermal budget required to achieve a complete activation. Both, surface and volume contaminated samples are investigated. During RTP treatments the activation of surface Cu atoms is found to proceed significantly faster than during standard furnace anneal. We tentatively attribute this behaviour to the UV light exposure associated with the RTP, which may enhance the release of copper atoms from the surface. The dissolution kinetics of the Cu precipitates occurring during RTPs are found to be only limited by Cu diffusion. The RTP/TID process is used to study the low temperature reaction path of supersaturated Cu. If prior to the RTP process, Cu atoms are chemically removed from the surface or near surface region, TID measures only the residual bulk Cu atoms. Our results show that out-diffusion and near-surface precipitation are reducing mostly the copper supersaturation.

  2. Modelling of phenomena associated with high burnup fuel behaviour during overpower transients

    International Nuclear Information System (INIS)

    Sills, H.E.; Langman, V.J.; Iglesias, F.C.

    1995-01-01

    Phenomena of importance to the behaviour of high burnup fuel subjected to conditions of rapid overpower (i.e., LWR RIAs) include the change in cladding material properties due to irradiation, pellet-clad interaction (PCI) and 'rim' effects associated with the periphery of high burnup fuel. 'Rim' effects are postulated to be caused by changes in fuel morphology at high burnup. Typical discharge burnups for CANDU fuel are low compared to LWRs. Maximum linear ratings for CANDU fuel are higher than those for LWRs. However, under normal operating conditions, the Zircaloy-4 clad of the CANDU fuel is collapsed onto the fuel stack. Thus, the CANDU fuel performance codes model the transient behaviour of the fuel-to-clad interface and are capable of assessing the potential for pellet-clad mechanical interaction (PCMI) failures for a wide range of overpower conditions. This report provides a discussion of the modelling of the phenomena of importance to high burnup fuel behaviour during rapid overpower transients. (author)

  3. Transient behaviour of deep underground salt caverns

    International Nuclear Information System (INIS)

    Karimi-Jafari, M.

    2007-11-01

    This work deals with the transient behaviour of deep underground salt caverns. It has been shown that a cavern is a complex system, in which there are mechanical, thermal, chemical and hydraulic evolutions. The importance of the transient evolutions, particularly the role of the 'reverse' creep in the interpretation of the tightness test in a salt cavern is revealed. Creep is characterized by a formulation of the behaviour law which presents the advantage, in a practical point of view, to only have a reduced number of parameters while accounting of the essential of what it is observed. The initiation of the rupture in the effective traction in a salt cavern rapidly pressurized is discussed. A model fitted to a very long term behaviour (after abandonment) is developed too. In this case too, a lot of phenomena, more or less coupled, occur, when the existing literature took only into account some phenomena. (O.M.)

  4. Temporal neural network for the identification of nuclear power plant transients

    International Nuclear Information System (INIS)

    Uluyol, O.; Ragheb, M.

    1993-01-01

    In this paper a layered spatiotemporal neural network is proposed for the identification of nuclear power plant transients. The developed layered spatiotemporal network is inspired by the formal avalanche structure developed by S. Grossberg and offers advantages compared with the stationary pattern approach using the perceptron paradigm. Each layer in the network is trained to recognize a separate time-dependent accident scenario. Within each scenario, the temporal behavior of the relevant parameters such as pressurizer pressure, pressurizer water volume, cold and hot legs temperatures, vessel flow, and power, are considered. Numerical cases are considered where the proposed methodology is applied to two nuclear power plant anticipated transient scenarios: the Station Blackout and the Anticipated Transient without Scram transients in a pressurized water reactor . The transient signatures used were generated by modeling the accidents using RELAP5/MOD2, a best-estimate thermal-hydraulics numerical code. The ability of the proposed layered spatiotemporal network to operate at different noise levels is investigated. Its incorporation within an Insightful Algorithm and Anticipatory Systems context for identifying and in predicting the course of nuclear transients is discussed

  5. Identification of nuclear power plant transients using the Particle Swarm Optimization algorithm

    International Nuclear Information System (INIS)

    Canedo Medeiros, Jose Antonio Carlos; Schirru, Roberto

    2008-01-01

    In order to help nuclear power plant operator reduce his cognitive load and increase his available time to maintain the plant operating in a safe condition, transient identification systems have been devised to help operators identify possible plant transients and take fast and right corrective actions in due time. In the design of classification systems for identification of nuclear power plants transients, several artificial intelligence techniques, involving expert systems, neuro-fuzzy and genetic algorithms have been used. In this work we explore the ability of the Particle Swarm Optimization algorithm (PSO) as a tool for optimizing a distance-based discrimination transient classification method, giving also an innovative solution for searching the best set of prototypes for identification of transients. The Particle Swarm Optimization algorithm was successfully applied to the optimization of a nuclear power plant transient identification problem. Comparing the PSO to similar methods found in literature it has shown better results

  6. Identification of nuclear power plant transients using the Particle Swarm Optimization algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Canedo Medeiros, Jose Antonio Carlos [Universidade Federal do Rio de Janeiro, PEN/COPPE, UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: canedo@lmp.ufrj.br; Schirru, Roberto [Universidade Federal do Rio de Janeiro, PEN/COPPE, UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: schirru@lmp.ufrj.br

    2008-04-15

    In order to help nuclear power plant operator reduce his cognitive load and increase his available time to maintain the plant operating in a safe condition, transient identification systems have been devised to help operators identify possible plant transients and take fast and right corrective actions in due time. In the design of classification systems for identification of nuclear power plants transients, several artificial intelligence techniques, involving expert systems, neuro-fuzzy and genetic algorithms have been used. In this work we explore the ability of the Particle Swarm Optimization algorithm (PSO) as a tool for optimizing a distance-based discrimination transient classification method, giving also an innovative solution for searching the best set of prototypes for identification of transients. The Particle Swarm Optimization algorithm was successfully applied to the optimization of a nuclear power plant transient identification problem. Comparing the PSO to similar methods found in literature it has shown better results.

  7. INTEGRAL observation of the Galactic transient Swift J174510.8-262411

    DEFF Research Database (Denmark)

    Vovk, I.; Ferrigno, C.; Bozzo, E.

    2012-01-01

    with time. On the base of the rapid flux increase, the high value of the energy cut-off and the absence of thermonuclear bursts, we argue that Swift J174510.8-262411 might be a new black-hole transient. Further observations at all wavelengths are encouraged to unveil the nature of this source. We thank...

  8. THEBES: a thermal hydraulic code for the calculation of transient two phase flow in bundle geometry

    International Nuclear Information System (INIS)

    Camous, F.

    1983-01-01

    The three dimensional thermal hydraulic code THEBES, capable to calculate transient boiling of sodium in rod bundles is described here. THEBES, derived from the transient single phase code SABRE-2A, was developed in CADARACHE by the SIES to analyse the SCARABEE N loss of flow experiments. This paper also presents the results of tests which were performed against various types of experiments: (1) transient boiling in a 7 pin bundle simulating a partial blockage at the bottom of a subassembly (rapid transient SCARABEE 7.2 experiment), (2) transient boiling in a 7 pin bundle simulating a coolant coast down (slow transient SCARABEE 7.3 experiment), (3) steady local and generalised boiling in a 19 pin bundle (GR 19 I experiment), (4) transient boiling in a 19 pin bundle simulating a coolant coast down (GR 19 I experiment), (5) steady local boiling in a 37 pin bundle with internal blockage (MOL 7C experiment). Excellent agreement was found between calculated and experimental results for these different situations. Our conclusion is that THEBES is able to calculate transient boiling of sodium in rod bundles in a quite satisfying way

  9. Analysis of transient fission gas behaviour in oxide fuel using BISON and TRANSURANUS

    Energy Technology Data Exchange (ETDEWEB)

    Barani, T.; Bruschi, E.; Pizzocri, D. [Politecnico di Milano, Department of Energy, Nuclear Engineering Division, Via La Masa 34, I-20156 Milano (Italy); Pastore, G. [Fuel Modeling and Simulation Department, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Van Uffelen, P. [European Commission, Joint Research Centre, Directorate for Nuclear Safety and Security, P.O. Box 2340, 76125 Karlsruhe (Germany); Williamson, R.L. [Fuel Modeling and Simulation Department, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3840 (United States); Luzzi, L., E-mail: Lelio.Luzzi@polimi.it [Politecnico di Milano, Department of Energy, Nuclear Engineering Division, Via La Masa 34, I-20156 Milano (Italy)

    2017-04-01

    The modelling of fission gas behaviour is a crucial aspect of nuclear fuel performance analysis in view of the related effects on the thermo-mechanical performance of the fuel rod, which can be particularly significant during transients. In particular, experimental observations indicate that substantial fission gas release (FGR) can occur on a small time scale during transients (burst release). To accurately reproduce the rapid kinetics of the burst release process in fuel performance calculations, a model that accounts for non-diffusional mechanisms such as fuel micro-cracking is needed. In this work, we present and assess a model for transient fission gas behaviour in oxide fuel, which is applied as an extension of conventional diffusion-based models to introduce the burst release effect. The concept and governing equations of the model are presented, and the sensitivity of results to the newly introduced parameters is evaluated through an analytic sensitivity analysis. The model is assessed for application to integral fuel rod analysis by implementation in two structurally different fuel performance codes: BISON (multi-dimensional finite element code) and TRANSURANUS (1.5D code). Model assessment is based on the analysis of 19 light water reactor fuel rod irradiation experiments from the OECD/NEA IFPE (International Fuel Performance Experiments) database, all of which are simulated with both codes. The results point out an improvement in both the quantitative predictions of integral fuel rod FGR and the qualitative representation of the FGR kinetics with the transient model relative to the canonical, purely diffusion-based models of the codes. The overall quantitative improvement of the integral FGR predictions in the two codes is comparable. Moreover, calculated radial profiles of xenon concentration after irradiation are investigated and compared to experimental data, illustrating the underlying representation of the physical mechanisms of burst release

  10. Severe hydramnios and preterm delivery in association with transient maternal diabetes insipidus.

    Science.gov (United States)

    Weinberg, Lori E; Dinsmoor, Mara J; Silver, Richard K

    2010-08-01

    Diabetes insipidus is rare in pregnancy. It is characterized by hypoosmolar polyuria and may be central, nephrogenic, or transient in etiology; the latter is presumably related to excess placental vasopresinase production. In theory, fetal effects of this endocrine condition may include hydramnios secondary to fetal polyuria. A pregnant patient developed rapid-onset second-trimester hydramnios that prompted a thorough fetal and maternal evaluation. She ultimately was diagnosed with transient diabetes insipidus of pregnancy because of an abrupt change in her voiding pattern at 20 weeks of gestation, significant polydipsia, and laboratory studies that revealed a hypoosmolar polyuria with normal serum and urine electrolytes. Transient neonatal polyuria also was confirmed in association with this unique maternal endocrine syndrome. The most likely cause of hydramnios in this case is transient maternal diabetes insipidus of pregnancy from excessive secretion of placental vasopressinase resulting in fetal polyuria. In cases of hydramnios of unknown etiology, if a history of maternal polyuria is elicited and confirmed, diabetes insipidus of pregnancy may play a role in some cases.

  11. Transient Go: A Mobile App for Transient Astronomy Outreach

    Science.gov (United States)

    Crichton, D.; Mahabal, A.; Djorgovski, S. G.; Drake, A.; Early, J.; Ivezic, Z.; Jacoby, S.; Kanbur, S.

    2016-12-01

    Augmented Reality (AR) is set to revolutionize human interaction with the real world as demonstrated by the phenomenal success of `Pokemon Go'. That very technology can be used to rekindle the interest in science at the school level. We are in the process of developing a prototype app based on sky maps that will use AR to introduce different classes of astronomical transients to students as they are discovered i.e. in real-time. This will involve transient streams from surveys such as the Catalina Real-time Transient Survey (CRTS) today and the Large Synoptic Survey Telescope (LSST) in the near future. The transient streams will be combined with archival and latest image cut-outs and other auxiliary data as well as historical and statistical perspectives on each of the transient types being served. Such an app could easily be adapted to work with various NASA missions and NSF projects to enrich the student experience.

  12. Transient splenium lesions in presurgical epilepsy patients: incidence and pathogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Nelles, M.; Falkenhausen, M. von; Urbach, H. [University of Bonn Medical Center, Department of Radiology/Neuroradiology, Bonn (Germany); Bien, C.G.; Kurthen, M. [University of Bonn Medical Center, Department of Epileptology, Bonn (Germany)

    2006-07-15

    Transient splenium corporis callosi (SCC) lesions are related to rapid reduction of antiepileptic drugs (AEDs). The range of substances with predilection for SCC changes, their pathophysiology and their occurrence are still unknown. In a prospective 2-year study an epilepsy-dedicated MRI protocol supplemented by DWI and ADC maps was performed after AED withdrawal for diagnostic seizure provocation in all patients with pharmacoresistant seizures locally admitted to the Department of Epileptology. Of 891 presurgical epilepsy patients, 6 (0.7%) had SCC lesions with cytotoxic edema on DWI. Carbamazepine combined with other AEDs was administered in five of those patients. In the study period we observed identical lesions in a schizophrenic patient treated with olanzapine and citalopram, in a patient with oropharyngeal carcinoma treated with alkylating agents, and in a hypernatremic patient following neurohypophyseal granular cell tumor surgery. Transient SCC lesions are related to rapid AED reduction but may occur in similar conditions with fluid balance alterations. We contribute further clinical data in this field to better classify the pharmaceuticals that are prone to the described cerebral cytotoxic side effects in the SCC and to clarify their incidence among presurgical epilepsy patients. (orig.)

  13. Transient splenium lesions in presurgical epilepsy patients: incidence and pathogenesis

    International Nuclear Information System (INIS)

    Nelles, M.; Falkenhausen, M. von; Urbach, H.; Bien, C.G.; Kurthen, M.

    2006-01-01

    Transient splenium corporis callosi (SCC) lesions are related to rapid reduction of antiepileptic drugs (AEDs). The range of substances with predilection for SCC changes, their pathophysiology and their occurrence are still unknown. In a prospective 2-year study an epilepsy-dedicated MRI protocol supplemented by DWI and ADC maps was performed after AED withdrawal for diagnostic seizure provocation in all patients with pharmacoresistant seizures locally admitted to the Department of Epileptology. Of 891 presurgical epilepsy patients, 6 (0.7%) had SCC lesions with cytotoxic edema on DWI. Carbamazepine combined with other AEDs was administered in five of those patients. In the study period we observed identical lesions in a schizophrenic patient treated with olanzapine and citalopram, in a patient with oropharyngeal carcinoma treated with alkylating agents, and in a hypernatremic patient following neurohypophyseal granular cell tumor surgery. Transient SCC lesions are related to rapid AED reduction but may occur in similar conditions with fluid balance alterations. We contribute further clinical data in this field to better classify the pharmaceuticals that are prone to the described cerebral cytotoxic side effects in the SCC and to clarify their incidence among presurgical epilepsy patients. (orig.)

  14. Transient Universe: Popular, Not so Popular & Knowable Unknowns

    Science.gov (United States)

    Bildsten, L.; Fryer, C.; Kulkarni, S.

    2006-03-01

    MOTIVATION & PURPOSE: This informal two day workshop is intended to bring together astronomers who monitor the sky for transient phenomena - a field which is poised to take off in the optical band, thanks to the exponential growth in the availability of giga pixel detectors, rapid computing and communication. For somewhat similar technological reasons, decimeter and decameter radio astronomy is also poised to grow in this area. The workshop will focus on astronomical opportunities with ongoing searches and discuss the possibilities with planned facilities in the near term. We hope to rapidly review the status of 'popular' sources (e.g. GRB afterglows, Supernovae, Machos), less popular events (e.g. Novae, geysers and gushers) and then move onto 'odd' but not hopelessly rare events. The spirit is to anticipate some of the discoveries by extending the astrophysical parameter space of known (or knowable) classes of transients. This workshop is part of the ongoing KITP Program "The Supernova Gamma Ray Burst Connection" and has received funding Los Alamos National Laboratory. We will follow the well honed KITP tradition of having fewer talks at the expense of long discussions. All talks will be recorded (per KITP tradition) and made available on the web for enjoyment, education and posterity. In lieu of a traditional poster sessions with old-fashioned easels we offer the Virtual Presence (organized by J. Bloom).

  15. APR1400 Locked Rotor Transient Analysis using KNAP

    International Nuclear Information System (INIS)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun

    2007-01-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR

  16. APR1400 Locked Rotor Transient Analysis using KNAP

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2007-07-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR.

  17. Transient analysis of intercalation electrodes for parameter estimation

    Science.gov (United States)

    Devan, Sheba

    An essential part of integrating batteries as power sources in any application, be it a large scale automotive application or a small scale portable application, is an efficient Battery Management System (BMS). The combination of a battery with the microprocessor based BMS (called "smart battery") helps prolong the life of the battery by operating in the optimal regime and provides accurate information regarding the battery to the end user. The main purposes of BMS are cell protection, monitoring and control, and communication between different components. These purposes are fulfilled by tracking the change in the parameters of the intercalation electrodes in the batteries. Consequently, the functions of the BMS should be prompt, which requires the methodology of extracting the parameters to be efficient in time. The traditional transient techniques applied so far may not be suitable due to reasons such as the inability to apply these techniques when the battery is under operation, long experimental time, etc. The primary aim of this research work is to design a fast, accurate and reliable technique that can be used to extract parameter values of the intercalation electrodes. A methodology based on analysis of the short time response to a sinusoidal input perturbation, in the time domain is demonstrated using a porous electrode model for an intercalation electrode. It is shown that the parameters associated with the interfacial processes occurring in the electrode can be determined rapidly, within a few milliseconds, by measuring the response in the transient region. The short time analysis in the time domain is then extended to a single particle model that involves bulk diffusion in the solid phase in addition to interfacial processes. A systematic procedure for sequential parameter estimation using sensitivity analysis is described. Further, the short time response and the input perturbation are transformed into the frequency domain using Fast Fourier Transform

  18. Delayed Transient Post-Traumatic Quadriplegia

    Directory of Open Access Journals (Sweden)

    Khaloud Al-Shaaibi

    2015-03-01

    Full Text Available Transient neurological deficit following cervical trauma have been reported following sports injuries, and has been referred to as cervical cord neurapraxia. The so-called "whiplash injuries" following minor motor vehicle collisions usually do not produce any neurological deficit. Here we report the case of a whiplash type of injury presenting with a delayed onset neurological deficit, which was followed by rapid and complete recovery. The patient, an otherwise healthy 34-year-old male, attended the emergency department of Sultan Qaboos University Hospital following a rear-end motor vehicle collision. We present images showing degenerative disc disease causing spinal canal narrowing and mild cord compression in the patient, but no spinal instability. Differential diagnoses are also discussed.

  19. Development of three dimensional transient analysis code STTA for SCWR core

    International Nuclear Information System (INIS)

    Wang, Lianjie; Zhao, Wenbo; Chen, Bingde; Yao, Dong; Yang, Ping

    2015-01-01

    Highlights: • A coupled three dimensional neutronics/thermal-hydraulics code STTA is developed for SCWR core transient analysis. • The Dynamic Link Libraries method is adopted for coupling computation for SCWR multi-flow core transient analysis. • The NEACRP-L-335 PWR benchmark problems are studied to verify STTA. • The SCWR rod ejection problems are studied to verify STTA. • STTA meets what is expected from a code for SCWR core 3-D transient preliminary analysis. - Abstract: A coupled three dimensional neutronics/thermal-hydraulics code STTA (SCWR Three dimensional Transient Analysis code) is developed for SCWR core transient analysis. Nodal Green’s Function Method based on the second boundary condition (NGFMN-K) is used for solving transient neutron diffusion equation. The SCWR sub-channel code ATHAS is integrated into NGFMN-K through the serial integration coupling approach. The NEACRP-L-335 PWR benchmark problem and SCWR rod ejection problems are studied to verify STTA. Numerical results show that the PWR solution of STTA agrees well with reference solutions and the SCWR solution is reasonable. The coupled code can be well applied to the core transients and accidents analysis with 3-D core model during both subcritical pressure and supercritical pressure operation

  20. Runaway transient simulation of a model Kaplan turbine

    Energy Technology Data Exchange (ETDEWEB)

    Liu, S; Liu, D; Wu, Y [State Key Laboratory of Hydroscience and Engineering, Department of Thermal Eng., Tsinghua University, Beijing, 100084 (China); Zhou, D [Water Conservancy and Hydropower Eng., Hohai University, Nanjing. 210098 (China); Nishi, M, E-mail: liushuhong@tsinghua.edu.c [Kyushu Inst. Tech. Senior Academy, Kitakyushu, 804-8550 (Japan)

    2010-08-15

    The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-{epsilon} turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.

  1. Runaway transient simulation of a model Kaplan turbine

    Science.gov (United States)

    Liu, S.; Zhou, D.; Liu, D.; Wu, Y.; Nishi, M.

    2010-08-01

    The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-epsilon turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.

  2. Runaway transient simulation of a model Kaplan turbine

    International Nuclear Information System (INIS)

    Liu, S; Liu, D; Wu, Y; Zhou, D; Nishi, M

    2010-01-01

    The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-ε turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.

  3. Classifier-ensemble incremental-learning procedure for nuclear transient identification at different operational conditions

    Energy Technology Data Exchange (ETDEWEB)

    Baraldi, Piero, E-mail: piero.baraldi@polimi.i [Dipartimento di Energia - Sezione Ingegneria Nucleare, Politecnico di Milano, via Ponzio 34/3, 20133 Milano (Italy); Razavi-Far, Roozbeh [Dipartimento di Energia - Sezione Ingegneria Nucleare, Politecnico di Milano, via Ponzio 34/3, 20133 Milano (Italy); Zio, Enrico [Dipartimento di Energia - Sezione Ingegneria Nucleare, Politecnico di Milano, via Ponzio 34/3, 20133 Milano (Italy); Ecole Centrale Paris-Supelec, Paris (France)

    2011-04-15

    An important requirement for the practical implementation of empirical diagnostic systems is the capability of classifying transients in all plant operational conditions. The present paper proposes an approach based on an ensemble of classifiers for incrementally learning transients under different operational conditions. New classifiers are added to the ensemble where transients occurring in new operational conditions are not satisfactorily classified. The construction of the ensemble is made by bagging; the base classifier is a supervised Fuzzy C Means (FCM) classifier whose outcomes are combined by majority voting. The incremental learning procedure is applied to the identification of simulated transients in the feedwater system of a Boiling Water Reactor (BWR) under different reactor power levels.

  4. Classifier-ensemble incremental-learning procedure for nuclear transient identification at different operational conditions

    International Nuclear Information System (INIS)

    Baraldi, Piero; Razavi-Far, Roozbeh; Zio, Enrico

    2011-01-01

    An important requirement for the practical implementation of empirical diagnostic systems is the capability of classifying transients in all plant operational conditions. The present paper proposes an approach based on an ensemble of classifiers for incrementally learning transients under different operational conditions. New classifiers are added to the ensemble where transients occurring in new operational conditions are not satisfactorily classified. The construction of the ensemble is made by bagging; the base classifier is a supervised Fuzzy C Means (FCM) classifier whose outcomes are combined by majority voting. The incremental learning procedure is applied to the identification of simulated transients in the feedwater system of a Boiling Water Reactor (BWR) under different reactor power levels.

  5. Application of an estimation model to predict future transients at US nuclear power plants

    International Nuclear Information System (INIS)

    Hallbert, B.P.; Blackman, H.S.

    1987-01-01

    A model developed by R.A. Fisher was applied to a set of Licensee Event Reports (LERs) summarizing transient initiating events at US commercial nuclear power plants. The empirical Bayes model was examined to study the feasibility of estimating the number of categories of transients which have not yet occurred at nuclear power plants. An examination of the model's predictive ability using an existing sample of data provided support for use of the model to estimate future transients. The estimate indicates that an approximate fifteen percent increase in the number of categories of transient initiating events may be expected during the period 1983--1993, assuming a stable process of transients. Limitations of the model and other possible applications are discussed. 10 refs., 1 fig., 3 tabs

  6. TMCC: a transient three-dimensional neutron transport code by the direct simulation method - 222

    International Nuclear Information System (INIS)

    Shen, H.; Li, Z.; Wang, K.; Yu, G.

    2010-01-01

    A direct simulation method (DSM) is applied to solve the transient three-dimensional neutron transport problems. DSM is based on the Monte Carlo method, and can be considered as an application of the Monte Carlo method in the specific type of problems. In this work, the transient neutronics problem is solved by simulating the dynamic behaviors of neutrons and precursors of delayed neutrons during the transient process. DSM gets rid of various approximations which are always necessary to other methods, so it is precise and flexible in the requirement of geometric configurations, material compositions and energy spectrum. In this paper, the theory of DSM is introduced first, and the numerical results obtained with the new transient analysis code, named TMCC (Transient Monte Carlo Code), are presented. (authors)

  7. Analyzing transient closed chamber effects on canopy gas exchange for optimizing flux calculation timing

    NARCIS (Netherlands)

    Langensiepen, M.; Kupisch, M.; Wijk, van M.T.; Ewert, F.

    2012-01-01

    Transient type canopy chambers are still the only currently available practical solution for rapid screening of gas-exchange in agricultural fields. The technique has been criticized for its effect on canopy microclimate during measurement which affects the transport regime and regulation of plant

  8. Prandtl number variation on transient forced convection flow in a ...

    African Journals Online (AJOL)

    user

    2Manufacturing Engineering Department, The Public Authority for Applied Education and ... A transient numerical study is conducted to investigate the transport .... The model describes a valve where it is possible to direct the flow into one.

  9. Electronically controlled mechanical seal for aerospace applications--Part 2: Transient tests

    Science.gov (United States)

    Wolff, Paul J.; Salant, Richard F.

    1995-01-01

    An electronically controlled mechanical seal for use as the purge gas seal in a liquid oxygen turbopump has been fabricated and tested under transient operating conditions. The thickness of the lubricating film is controlled by adjusting the coning of the carbon face. This is accomplished by applying a voltage to a piezoelectric actuator to which the carbon face is bonded. The seal has been operated with a closed-loop control system that utilizes either the leakage rate or seal face temperature as the feedback. Both speed and pressure transients have been imposed on the seal. The transient tests have demonstrated that the seal is capable of maintaing low leakage rates while limiting face temperatures.

  10. Response of dairy cattle to transient voltages and magnetic fields

    International Nuclear Information System (INIS)

    Reinemann, D.J.; Laughlin, N.K.; Stetson, L.E.

    1995-01-01

    Stray voltages in dairy facilities have been studied since the 1970's. Previous research using steady-state ac and dc voltages has defined cow-contact voltage levels which may cause behavior and associated production problems. This research was designed to address concerns over possible effects of transient voltages and magnetic fields on dairy cows. Dairy cows response to transient voltages and magnetic fields was measured. The waveforms of the transient voltages applied were: 5 cycles of 60-Hz ac with a total pulse time of 83 ms, 1 cycle of 60-Hz ac with a total pulse time of 16 ms, and 1 cycle of an ac square wave (spiking positive and negative) of 2-ms duration. Alternating magnetic fields were produced by passing 60-Hz ac fundamental frequency with 2nd and 3rd harmonic and random noise components in metal structures around the cows. The maximum magnetic field associated with this current flow was in excess of 4 G. A wide range of sensitivity to transient voltages was observed among cows. Response levels from 24 cows to each transient exposure were normally distributed. No responses to magnetic fields were observed

  11. Resonant and off-resonant transients in electromagnetically induced transparency: Turn-on and turn-off dynamics

    International Nuclear Information System (INIS)

    Greentree, Andrew D.; Smith, T.B.; Echaniz, S.R. de; Durrant, A. V.; Marangos, J.P.; Segal, D.M.; Vaccaro, J.A.

    2002-01-01

    This paper presents a wide-ranging theoretical and experimental study of nonadiabatic transient phenomena in a Λ electromagnetically induced transparency system when a strong coupling field is rapidly switched on or off. The theoretical treatment uses a Laplace transform approach to solve the time-dependent density matrix equation. The experiments are carried out in a 87 Rb magneto-optical trap. The results show transient probe gain in parameter regions not previously studied, and provide insight into the transition dynamics between bare and dressed states

  12. RF control at transient beamloading for high-duty-factor linacs

    Energy Technology Data Exchange (ETDEWEB)

    Chernogubovsky, M.A.; Sugimoto, Masayoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-08-01

    An effective RF control with the transient beamloading is the major issue in the operation of the high-duty-factor linacs to suppress the undesirable beam loss. The RF control method is considered to obtain the control principle and the state equation, under the analysis of electrodynamical properties of the excitation in the resonator of the linac due to the transient beamloading. The concept of the directional selective coupling is applied for the RF system to define the main characteristics and to optimize the RF control parameters. (author)

  13. Transient compressible flows in porous media

    International Nuclear Information System (INIS)

    Morrison, F.A. Jr.

    1975-09-01

    Transient compressible flow in porous media was investigated analytically. The major portion of the investigation was directed toward improving and understanding of dispersion in these flows and developing rapid accurate numerical techniques for predicting the extent of dispersion. The results are of interest in the containment of underground nuclear experiments. The transient one-dimensional transport of a trace component in a gas flow is analyzed. A conservation equation accounting for the effects of convective transport, dispersive transport, and decay, is developed. This relation, as well as a relation governing the fluid flow, is used to predict trace component concentration as a function of position and time. A detailed analysis of transport associated with the isothermal flow of an ideal gas is done. Because the governing equations are nonlinear, numerical calculations are performed. The ideal gas flow is calculated using a highly stable implicit iterative procedure with an Eulerian mesh. In order to avoid problems of anomolous dispersion associated with finite difference calculation, trace component convection and dispersion are calculated using a Lagrangian mesh. Details of the Eulerian-Lagrangian numerical technique are presented. Computer codes have been developed and implemented on the Lawrence Livermore Laboratory computer system

  14. Transient surface states during the CBE growth of GaAs

    Science.gov (United States)

    Farrell, T.; Hill, D.; Joyce, T. B.; Bullough, T. J.; Weightman, P.

    1997-05-01

    We report the occurrence of a transient surface state during the initial stages of CBE GaAs(0 0 1) growth. The state was detected in real-time reflectance ( R) and reflectance anisotropy spectroscopy (RAS) growth monitoring. At low growth rates, less than 1 μm/h, beam equivalent pressure (BEP) of triethylgallium (TEG) BEPs there was a rapid increase in R at all monitoring wavelengths, followed by a monotonic decay to its pre-growth value. This transient increase in R was accompanied by a change in the RAS signal, the magnitude and sign of which varied with wavelength. The initial increase in R is shown to be associated with the development of a metallic-like surface whereas the changes in the RAS signal are consistent with the formation of Ga dimers.

  15. Simulation of transient fluid flow in mold region during steel continuous casting

    International Nuclear Information System (INIS)

    Liu, R; Thomas, B G; Sengupta, J

    2012-01-01

    A system of models has been developed to study transient flow during continuous casting and applied to simulate an event of multiple stopper-rod movements. It includes four sub-models to incorporate different aspects in this transient event. A three-dimensional (3-D) porous-flow model of the nozzle wall calculates the rate argon gas flow into the liquid steel, and the initial mean bubble size is estimated. Transient CFD models simulate multiphase flow of steel and gas bubbles in the Submerged Entry Nozzle (SEN) and mold and have been validated with experimental data from both nail dipping and Sub-meniscus Velocity Control (SVC) measurements. To obtain the transient inlet boundary conditions for the simulation, two semi-empirical models, a stopper-rod-position based model and a metal-level-based model, predict the liquid steel flow rate through the SEN based on recorded plant data. Finally the model system was applied to study the effects of stopper rod movements on SEN/mold flow patterns. Meniscus level fluctuations were calculated using a simple pressure method and compared well with plant measurements. Insights were gained from the simulation results to explain the cause of meniscus level fluctuations and the formation of sliver defects during stopper rod movements.

  16. Current interruption transients calculation

    CERN Document Server

    Peelo, David F

    2014-01-01

    Provides an original, detailed and practical description of current interruption transients, origins, and the circuits involved, and how they can be calculated Current Interruption Transients Calculationis a comprehensive resource for the understanding, calculation and analysis of the transient recovery voltages (TRVs) and related re-ignition or re-striking transients associated with fault current interruption and the switching of inductive and capacitive load currents in circuits. This book provides an original, detailed and practical description of current interruption transients, origins,

  17. Environmentally-induced discharge transient coupling to spacecraft

    Science.gov (United States)

    Viswanathan, R.; Barbay, G.; Stevens, N. J.

    1985-01-01

    The Hughes SCREENS (Space Craft Response to Environments of Space) technique was applied to generic spin and 3-axis stabilized spacecraft models. It involved the NASCAP modeling for surface charging and lumped element modeling for transients coupling into a spacecraft. A differential voltage between antenna and spun shelf of approx. 400 V and current of 12 A resulted from discharge at antenna for the spinner and approx. 3 kv and 0.3 A from a discharge at solar panels for the 3-axis stabilized Spacecraft. A typical interface circuit response was analyzed to show that the transients would couple into the Spacecraft System through ground points, which are most vulnerable. A compilation and review was performed on 15 years of available data from electron and ion current collection phenomena. Empirical models were developed to match data and compared with flight data of Pix-1 and Pix-2 mission. It was found that large space power systems would float negative and discharge if operated at or above 300 V. Several recommendations are given to improve the models and to apply them to large space systems.

  18. LOFT/L6-7, Loss of Fluid Test, Anticipated Transients with Multiple Failures

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This was the seventh in the NRC L6 Series of Anticipated Transients experiments. Rapid secondary side induced cooldown was studied. The experiment was conducted on 31 September 1981

  19. Transient ischemic attack presenting in an elderly patient with transient ophthalmic manifestations

    Directory of Open Access Journals (Sweden)

    Sparshi Jain

    2016-01-01

    Full Text Available Transient ischemic attack (TIA is a transient neurological deficit of cerebrovascular origin without infarction which may last only for a short period and can have varying presentations. We report a case of 58-year-old male with presenting features of sudden onset transient vertical diplopia and transient rotatory nystagmus which self-resolved within 12 h. Patient had no history of any systemic illness. On investigating, hematological investigations and neuroimaging could not explain these sudden and transient findings. A TIA could possibly explain these sudden and transient ocular findings in our patient. This case report aims to highlight the importance of TIA for ophthalmologists. We must not ignore these findings as these could be warning signs of an impending stroke which may or may not be detected on neuroimaging. Thus, early recognition, primary prevention strategies, and timely intervention are needed.

  20. Current status of the transient integral fuel element performance code URANUS

    International Nuclear Information System (INIS)

    Preusser, T.; Lassmann, K.

    1983-01-01

    To investigate the behavior of fuel pins during normal and off-normal operation, the integral fuel rod code URANUS has been extended to include a transient version. The paper describes the current status of the program system including a presentation of newly developed models for hypothetical accident investigation. The main objective of current development work is to improve the modelling of fuel and clad material behavior during fast transients. URANUS allows detailed analysis of experiments until the onset of strong material transport phenomena. Transient fission gas analysis is carried out due to the coupling with a special version of the LANGZEIT-KURZZEIT-code (KfK). Fuel restructuring and grain growth kinetics models have been improved recently to better characterize pre-experimental steady-state operation; transient models are under development. Extensive verification of the new version has been carried out by comparison with analytical solutions, experimental evidence, and code-to-code evaluation studies. URANUS, with all these improvements, has been successfully applied to difficult fast breeder fuel rod analysis including TOP, LOF, TUCOP, local coolant blockage and specific carbide fuel experiments. Objective of further studies is the description of transient PCMI. It is expected that the results of these developments will contribute significantly to the understanding of fuel element structural behavior during severe transients. (orig.)

  1. EVENT, Explosive Transients in Flow Networks

    International Nuclear Information System (INIS)

    Andrae, R.W.; Tang, P.K.; Bolstad, J.W.; Gregory, W.S.

    1985-01-01

    1 - Description of problem or function: A major concern of the chemical, nuclear, and mining industries is the occurrence of an explosion in one part of a facility and subsequent transmission of explosive effects through the ventilation system. An explosive event can cause performance degradation of the ventilation system or even structural failures. A more serious consequence is the release of hazardous materials to the environment if vital protective devices such as air filters, are damaged. EVENT was developed to investigate the effects of explosive transients through fluid-flow networks. Using the principles of fluid mechanics and thermodynamics, governing equations for the conservation of mass, energy, and momentum are formulated. These equations are applied to the complete network subdivided into two general components: nodes and branches. The nodes represent boundaries and internal junctions where the conservation of mass and energy applies. The branches can be ducts, valves, blowers, or filters. Since in EVENT the effect of the explosion, not the characteristics of the explosion itself, is of interest, the transient is simulated in the simplest possible way. A rapid addition of mass and energy to the system at certain locations is used. This representation is adequate for all of the network except the region where the explosion actually occurs. EVENT84 is a modification of EVENT which includes a new explosion chamber model subroutine based on the NOL BLAST program developed at the Naval Ordnance Laboratory, Silver Spring, Maryland. This subroutine calculates the confined explosion near-field parameters and supplies the time functions of energy and mass injection. Solid-phase or TNT-equivalent explosions (which simulate 'point source' explosions in nuclear facilities) as well as explosions in gas-air mixtures can be simulated. The four types of explosions EVENT84 simulates are TNT, hydrogen in air, acetylene in air, and tributyl phosphate (TBP or 'red oil

  2. Transiently chaotic neural networks with piecewise linear output functions

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S.-S. [Department of Mathematics, National Taiwan Normal University, Taipei, Taiwan (China); Shih, C.-W. [Department of Applied Mathematics, National Chiao Tung University, 1001 Ta-Hsueh Road, Hsinchu, Taiwan (China)], E-mail: cwshih@math.nctu.edu.tw

    2009-01-30

    Admitting both transient chaotic phase and convergent phase, the transiently chaotic neural network (TCNN) provides superior performance than the classical networks in solving combinatorial optimization problems. We derive concrete parameter conditions for these two essential dynamic phases of the TCNN with piecewise linear output function. The confirmation for chaotic dynamics of the system results from a successful application of the Marotto theorem which was recently clarified. Numerical simulation on applying the TCNN with piecewise linear output function is carried out to find the optimal solution of a travelling salesman problem. It is demonstrated that the performance is even better than the previous TCNN model with logistic output function.

  3. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  4. Transient behavior of flare-associated solar wind. II - Gas dynamics in a nonradial open field region

    Science.gov (United States)

    Nagai, F.

    1984-01-01

    Transient behavior of flare-associated solar wind in the nonradial open field region is numerically investigated, taking into account the thermal and dynamical coupling between the chromosphere and the corona. A realistic steady solar wind is constructed which passes through the inner X-type critical point in the rapidly diverging region. The wind speed shows a local maximum at the middle, O-type, critical point. The wind's density and pressure distributions decrease abruptly in the rapidly diverging region of the flow tube. The transient behavior of the wind following flare energy deposition includes ascending and descending conduction fronts. Thermal instability occurs in the lower corona, and ascending material flows out through the throat after the flare energy input ceases. A local density distribution peak is generated at the shock front due to the pressure deficit just behind the shock front.

  5. UNSUPERVISED TRANSIENT LIGHT CURVE ANALYSIS VIA HIERARCHICAL BAYESIAN INFERENCE

    International Nuclear Information System (INIS)

    Sanders, N. E.; Soderberg, A. M.; Betancourt, M.

    2015-01-01

    Historically, light curve studies of supernovae (SNe) and other transient classes have focused on individual objects with copious and high signal-to-noise observations. In the nascent era of wide field transient searches, objects with detailed observations are decreasing as a fraction of the overall known SN population, and this strategy sacrifices the majority of the information contained in the data about the underlying population of transients. A population level modeling approach, simultaneously fitting all available observations of objects in a transient sub-class of interest, fully mines the data to infer the properties of the population and avoids certain systematic biases. We present a novel hierarchical Bayesian statistical model for population level modeling of transient light curves, and discuss its implementation using an efficient Hamiltonian Monte Carlo technique. As a test case, we apply this model to the Type IIP SN sample from the Pan-STARRS1 Medium Deep Survey, consisting of 18,837 photometric observations of 76 SNe, corresponding to a joint posterior distribution with 9176 parameters under our model. Our hierarchical model fits provide improved constraints on light curve parameters relevant to the physical properties of their progenitor stars relative to modeling individual light curves alone. Moreover, we directly evaluate the probability for occurrence rates of unseen light curve characteristics from the model hyperparameters, addressing observational biases in survey methodology. We view this modeling framework as an unsupervised machine learning technique with the ability to maximize scientific returns from data to be collected by future wide field transient searches like LSST

  6. UNSUPERVISED TRANSIENT LIGHT CURVE ANALYSIS VIA HIERARCHICAL BAYESIAN INFERENCE

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, N. E.; Soderberg, A. M. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Betancourt, M., E-mail: nsanders@cfa.harvard.edu [Department of Statistics, University of Warwick, Coventry CV4 7AL (United Kingdom)

    2015-02-10

    Historically, light curve studies of supernovae (SNe) and other transient classes have focused on individual objects with copious and high signal-to-noise observations. In the nascent era of wide field transient searches, objects with detailed observations are decreasing as a fraction of the overall known SN population, and this strategy sacrifices the majority of the information contained in the data about the underlying population of transients. A population level modeling approach, simultaneously fitting all available observations of objects in a transient sub-class of interest, fully mines the data to infer the properties of the population and avoids certain systematic biases. We present a novel hierarchical Bayesian statistical model for population level modeling of transient light curves, and discuss its implementation using an efficient Hamiltonian Monte Carlo technique. As a test case, we apply this model to the Type IIP SN sample from the Pan-STARRS1 Medium Deep Survey, consisting of 18,837 photometric observations of 76 SNe, corresponding to a joint posterior distribution with 9176 parameters under our model. Our hierarchical model fits provide improved constraints on light curve parameters relevant to the physical properties of their progenitor stars relative to modeling individual light curves alone. Moreover, we directly evaluate the probability for occurrence rates of unseen light curve characteristics from the model hyperparameters, addressing observational biases in survey methodology. We view this modeling framework as an unsupervised machine learning technique with the ability to maximize scientific returns from data to be collected by future wide field transient searches like LSST.

  7. Simulation of Thermal Transients using CSMP

    International Nuclear Information System (INIS)

    Konuk, A.A.

    1981-01-01

    A mathematical model has been developed to simulate thermal transientes for the Hellum Loop of the 'Instituto de Pesquisas Energeticas e Nuleares', Sao Paulo. The model is based on the energy equation applied to the various components of the loop. The non-linear system of first order ordinary differential equation and algebraic equations has been solved using IBM'S 'System/360-Continuous System Modeling Program-CSMP'. The model has been tested satisfactory with experimental results. (Author) [pt

  8. Newborn hearing screening with transient evoked otoacoustic emissions and automatic auditory brainstem response

    OpenAIRE

    Renata Mota Mamede de Carvallo; Carla Gentile Matas; Isabela de Souza Jardim

    2008-01-01

    Objective: The aim of the present investigation was to check Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response tests applied together in regular nurseries and Newborn Intensive Care Units (NICU), as well as to describe and compare the results obtained in both groups. Methods: We tested 150 newborns from regular nurseries and 70 from NICU. Rresults: The newborn hearing screening results using Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem...

  9. Detecting aseismic strain transients from seismicity data

    Science.gov (United States)

    Llenos, A.L.; McGuire, J.J.

    2011-01-01

    Aseismic deformation transients such as fluid flow, magma migration, and slow slip can trigger changes in seismicity rate. We present a method that can detect these seismicity rate variations and utilize these anomalies to constrain the underlying variations in stressing rate. Because ordinary aftershock sequences often obscure changes in the background seismicity caused by aseismic processes, we combine the stochastic Epidemic Type Aftershock Sequence model that describes aftershock sequences well and the physically based rate- and state-dependent friction seismicity model into a single seismicity rate model that models both aftershock activity and changes in background seismicity rate. We implement this model into a data assimilation algorithm that inverts seismicity catalogs to estimate space-time variations in stressing rate. We evaluate the method using a synthetic catalog, and then apply it to a catalog of M???1.5 events that occurred in the Salton Trough from 1990 to 2009. We validate our stressing rate estimates by comparing them to estimates from a geodetically derived slip model for a large creep event on the Obsidian Buttes fault. The results demonstrate that our approach can identify large aseismic deformation transients in a multidecade long earthquake catalog and roughly constrain the absolute magnitude of the stressing rate transients. Our method can therefore provide a way to detect aseismic transients in regions where geodetic resolution in space or time is poor. Copyright 2011 by the American Geophysical Union.

  10. Real-Time Gas Identification by Analyzing the Transient Response of Capillary-Attached Conductive Gas Sensor

    Directory of Open Access Journals (Sweden)

    Behzad Bahraminejad

    2010-05-01

    Full Text Available In this study, the ability of the Capillary-attached conductive gas sensor (CGS in real-time gas identification was investigated. The structure of the prototype fabricated CGS is presented. Portions were selected from the beginning of the CGS transient response including the first 11 samples to the first 100 samples. Different feature extraction and classification methods were applied on the selected portions. Validation of methods was evaluated to study the ability of an early portion of the CGS transient response in target gas (TG identification. Experimental results proved that applying extracted features from an early part of the CGS transient response along with a classifier can distinguish short-chain alcohols from each other perfectly. Decreasing time of exposition in the interaction between target gas and sensing element improved the reliability of the sensor. Classification rate was also improved and time of identification was decreased. Moreover, the results indicated the optimum interval of the early transient response of the CGS for selecting portions to achieve the best classification rates.

  11. Transient and steady-state currents in epoxy resin

    International Nuclear Information System (INIS)

    Guillermin, Christophe; Rain, Pascal; Rowe, Stephen W

    2006-01-01

    Charging and discharging currents have been measured in a diglycidyl ether of bisphenol-A epoxy resin with and without silica fillers, below and above its glass transition temperature T g = 65 deg. C. Both transient and steady-state current densities have been analysed. The average applied fields ranged from 3 to 35 kV mm -1 with a sample thickness of 0.5 mm. Above T g , transient currents suggested a phenomenon of charge injection forming trapped space charges even at low fields. Steady-state currents confirmed that the behaviour was not Ohmic and suggested Schottky-type injection. Below T g , the current is not controlled by the metal-dielectric interface but by the conduction in the volume: the current is Ohmic at low fields and both transient and steady-state currents suggest a phenomenon of space-charge limited currents at high fields. The field threshold is similar in the filler-free and the filled resin. Values in the range 12-17 kV mm -1 have been measured

  12. Transient and steady-state currents in epoxy resin

    Energy Technology Data Exchange (ETDEWEB)

    Guillermin, Christophe [Schneider Electric Industries S.A.S., 37 quai Paul-Louis Merlin, 38050 Grenoble Cedex 9 (France); Rain, Pascal [Laboratoire d' Electrostatique et de Materiaux Dielectriques (LEMD), CNRS, 25 avenue des Martyrs, 38042 Grenoble Cedex 9 (France); Rowe, Stephen W [Schneider Electric Industries S.A.S., 37 quai Paul-Louis Merlin, 38050 Grenoble Cedex 9 (France)

    2006-02-07

    Charging and discharging currents have been measured in a diglycidyl ether of bisphenol-A epoxy resin with and without silica fillers, below and above its glass transition temperature T{sub g} = 65 deg. C. Both transient and steady-state current densities have been analysed. The average applied fields ranged from 3 to 35 kV mm{sup -1} with a sample thickness of 0.5 mm. Above T{sub g}, transient currents suggested a phenomenon of charge injection forming trapped space charges even at low fields. Steady-state currents confirmed that the behaviour was not Ohmic and suggested Schottky-type injection. Below T{sub g}, the current is not controlled by the metal-dielectric interface but by the conduction in the volume: the current is Ohmic at low fields and both transient and steady-state currents suggest a phenomenon of space-charge limited currents at high fields. The field threshold is similar in the filler-free and the filled resin. Values in the range 12-17 kV mm{sup -1} have been measured.

  13. Application of neural networks to connectional expert system for identification of transients in nuclear power plants

    International Nuclear Information System (INIS)

    Cheon, Se Woo; Kim, Wan Joo; Chang, Soon Heung; Roh, Myung Sub

    1991-01-01

    The Back-propagation Neural Network (BPN) algorithm is applied to connectionist expert system for the identification of BWR transients. Several powerful features of neural network-based expert systems over traditional rule-based expert systems are described. The general mapping capability of the neural networks enables to identify transients easily. A number of case studies were performed with emphasis on the applicability of the neural networks to the diagnostic domain. It is revealed that the BPN algorithm can identify transients properly, even when incomplete or untrained symptoms are given. It is also shown that multiple transients are easily identified

  14. Recent activity of the Rapid Burster (MXB 1730-335)

    DEFF Research Database (Denmark)

    Kuulkers, E.; Brandt, Søren Kristian; Markwardt, C.

    2008-01-01

    Observations taken as part of the INTEGRAL Galactic bulge monitoring program (see ATel #1385) on 2008, February 23 13:32-17:13 (UT) showed bursting activity from the X-ray transient, the Rapid Burster (MXB 1730-335). During one of the 1800-sec pointings when the source was in the field- of-view o...

  15. Pre-steady state transients in the Drosophila alcohol dehydrogenase catalyzed reaction: isotope effects and stereospecificity

    International Nuclear Information System (INIS)

    Place, A.R.; Eccleston, J.F.

    1987-01-01

    The alcohol dehydrogenase (ADH) isolated from Drosophila is unique among alcohol metabolizing enzymes by not requiring metals for catalysis, by showing 4-pro-S (B-sided) hydride transfer stereospecificity, and by possessing a greater catalytic turnover rate for secondary alcohols than for primary alcohols. They have extended their studies on the kinetic mechanism for this enzyme by examining the pre-steady state transients of ternary complex interconversion using stopped-flow fluorescence methods. When enzyme and a 30-fold molar excess of NADH is mixed with excess acetadehyde, methyl ethyl ketone (MEK), or cyclohexanone a rapid (> 100 s -1 ) transient is observe before the steady-state. The rates are insensitive to isotope substitution. With the substrate MEK, the rate and amplitude suggests a single turnover of the enzyme. Similar pre-steady state transients are observed when enzyme and a 50-fold molar excess of NAD + is mixed with ethanol, 2-propanol, and cyclohexanol. The rates show a hyperbolic concentration dependence and a deuterium isotope effect. With d 6 -deuteroethanol the transient no longer occurs in the pre-steady state. When the optical isomers of secondary alcohols are used as substrates, transients are observed only in the R-(-) isomers for all chain lengths. With 2-S(+)-heptanol and 2-S(+)-octanol no transients occur

  16. Transient light-induced intracellular oxidation revealed by redox biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Kolossov, Vladimir L., E-mail: viadimer@illinois.edu [Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801 (United States); Beaudoin, Jessica N. [Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801 (United States); Department of Animal Sciences, University of Illinois at Urbana-Champaign, 1207 W. Gregory Drive, Urbana, IL 61801 (United States); Hanafin, William P. [Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801 (United States); DiLiberto, Stephen J. [Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801 (United States); Department of Animal Sciences, University of Illinois at Urbana-Champaign, 1207 W. Gregory Drive, Urbana, IL 61801 (United States); Kenis, Paul J.A. [Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801 (United States); Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 S. Mathews Avenue, Urbana, IL 61801 (United States); Rex Gaskins, H. [Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 W. Gregory Drive, Urbana, IL 61801 (United States); Department of Animal Sciences, University of Illinois at Urbana-Champaign, 1207 W. Gregory Drive, Urbana, IL 61801 (United States); Department of Pathobiology, University of Illinois at Urbana-Champaign, 2001 S. Lincoln Avenue, Urbana, IL 61801 (United States); Division of Nutritional Sciences, University of Illinois at Urbana-Champaign, 905 S. Goodwin Avenue, Urbana, IL 61801 (United States)

    2013-10-04

    Highlights: •Time-resolved live cell imaging revealed light-induced oxidation. •Only the roGFP probe fused with glutaredoxin reveals photooxidation. •The transient oxidation is rapidly reduced by the cytosolic antioxidant system. •Intracellular photooxidation is media-dependent. •Oxidation is triggered exclusively by exposure to short wavelength excitation. -- Abstract: We have implemented a ratiometric, genetically encoded redox-sensitive green fluorescent protein fused to human glutaredoxin (Grx1-roGFP2) to monitor real time intracellular glutathione redox potentials of mammalian cells. This probe enabled detection of media-dependent oxidation of the cytosol triggered by short wavelength excitation. The transient nature of light-induced oxidation was revealed by time-lapse live cell imaging when time intervals of less than 30 s were implemented. In contrast, transient ROS generation was not observed with the parental roGFP2 probe without Grx1, which exhibits slower thiol-disulfide exchange. These data demonstrate that the enhanced sensitivity of the Grx1-roGFP2 fusion protein enables the detection of short-lived ROS in living cells. The superior sensitivity of Grx1-roGFP2, however, also enhances responsiveness to environmental cues introducing a greater likelihood of false positive results during image acquisition.

  17. Transient light-induced intracellular oxidation revealed by redox biosensor

    International Nuclear Information System (INIS)

    Kolossov, Vladimir L.; Beaudoin, Jessica N.; Hanafin, William P.; DiLiberto, Stephen J.; Kenis, Paul J.A.; Rex Gaskins, H.

    2013-01-01

    Highlights: •Time-resolved live cell imaging revealed light-induced oxidation. •Only the roGFP probe fused with glutaredoxin reveals photooxidation. •The transient oxidation is rapidly reduced by the cytosolic antioxidant system. •Intracellular photooxidation is media-dependent. •Oxidation is triggered exclusively by exposure to short wavelength excitation. -- Abstract: We have implemented a ratiometric, genetically encoded redox-sensitive green fluorescent protein fused to human glutaredoxin (Grx1-roGFP2) to monitor real time intracellular glutathione redox potentials of mammalian cells. This probe enabled detection of media-dependent oxidation of the cytosol triggered by short wavelength excitation. The transient nature of light-induced oxidation was revealed by time-lapse live cell imaging when time intervals of less than 30 s were implemented. In contrast, transient ROS generation was not observed with the parental roGFP2 probe without Grx1, which exhibits slower thiol-disulfide exchange. These data demonstrate that the enhanced sensitivity of the Grx1-roGFP2 fusion protein enables the detection of short-lived ROS in living cells. The superior sensitivity of Grx1-roGFP2, however, also enhances responsiveness to environmental cues introducing a greater likelihood of false positive results during image acquisition

  18. Transient drainage summary report

    International Nuclear Information System (INIS)

    1996-09-01

    This report summarizes the history of transient drainage issues on the Uranium Mill Tailings Remedial Action (UMTRA) Project. It defines and describes the UMTRA Project disposal cell transient drainage process and chronicles UMTRA Project treatment of the transient drainage phenomenon. Section 4.0 includes a conceptual cross section of each UMTRA Project disposal site and summarizes design and construction information, the ground water protection strategy, and the potential for transient drainage

  19. TRANSIENT ELECTRONICS CATEGORIZATION

    Science.gov (United States)

    2017-08-24

    AFRL-RY-WP-TR-2017-0169 TRANSIENT ELECTRONICS CATEGORIZATION Dr. Burhan Bayraktaroglu Devices for Sensing Branch Aerospace Components & Subsystems...SUBTITLE TRANSIENT ELECTRONICS CATEGORIZATION 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER N/A 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S) Dr. Burhan...88ABW-2017-3747, Clearance Date 31 July 2017. Paper contains color. 14. ABSTRACT Transient electronics is an emerging technology area that lacks proper

  20. Transient performance simulation of aircraft engine integrated with fuel and control systems

    International Nuclear Information System (INIS)

    Wang, C.; Li, Y.G.; Yang, B.Y.

    2017-01-01

    Highlights: • A new performance simulation method for engine hydraulic fuel systems is introduced. • Time delay of engine performance due to fuel system model is noticeable but small. • The method provides details of fuel system behavior in engine transient processes. • The method could be used to support engine and fuel system designs. - Abstract: A new method for the simulation of gas turbine fuel systems based on an inter-component volume method has been developed. It is able to simulate the performance of each of the hydraulic components of a fuel system using physics-based models, which potentially offers more accurate results compared with those using transfer functions. A transient performance simulation system has been set up for gas turbine engines based on an inter-component volume (ICV) method. A proportional-integral (PI) control strategy is used for the simulation of engine controller. An integrated engine and its control and hydraulic fuel systems has been set up to investigate their coupling effect during engine transient processes. The developed simulation system has been applied to a model aero engine. The results show that the delay of the engine transient response due to the inclusion of the fuel system model is noticeable although relatively small. The developed method is generic and can be applied to any other gas turbines and their control and fuel systems.

  1. Design, Construction, and Validation of Artificial MicroRNA Vectors Using Agrobacterium-Mediated Transient Expression System.

    Science.gov (United States)

    Bhagwat, Basdeo; Chi, Ming; Han, Dianwei; Tang, Haifeng; Tang, Guiliang; Xiang, Yu

    2016-01-01

    Artificial microRNA (amiRNA) technology utilizes microRNA (miRNA) biogenesis pathway to produce artificially selected small RNAs using miRNA gene backbone. It provides a feasible strategy for inducing loss of gene function, and has been applied in functional genomics study, improvement of crop quality and plant virus disease resistance. A big challenge in amiRNA applications is the unpredictability of silencing efficacy of the designed amiRNAs and not all constructed amiRNA candidates would be expressed effectively in plant cells. We and others found that high efficiency and specificity in RNA silencing can be achieved by designing amiRNAs with perfect or almost perfect sequence complementarity to their targets. In addition, we recently demonstrated that Agrobacterium-mediated transient expression system can be used to validate amiRNA constructs, which provides a simple, rapid and effective method to select highly expressible amiRNA candidates for stable genetic transformation. Here, we describe the methods for design of amiRNA candidates with perfect or almost perfect base-pairing to the target gene or gene groups, incorporation of amiRNA candidates in miR168a gene backbone by one step inverse PCR amplification, construction of plant amiRNA expression vectors, and assay of transient expression of amiRNAs in Nicotiana benthamiana through agro-infiltration, small RNA extraction, and amiRNA Northern blot.

  2. Analysis of very fast transients in layer-type transformer windings

    NARCIS (Netherlands)

    Popov, M.; Sluis, van der L.; Smeets, R.; Lopez Roldan, J.

    2007-01-01

    This paper deals with the measurement, modeling, and simulation of very fast transient overvoltages in layer-type distribution transformer windings. Measurements were performed by applying a step impulse with 50-ns rise time on a single-phase test transformer equipped with measuring points along the

  3. Control Design of VSIs to Enhance Transient Performance in Microgrids

    DEFF Research Database (Denmark)

    Federico, de Bosio; Antonio DeSouza Ribeiro, Luiz; Savaghebi, Mehdi

    2016-01-01

    This paper discusses the control design for an islanded microgrid in order to ensure acceptable performance in terms of voltage quality and load sharing by focusing on transient conditions. To this aim, state feedback decoupling approach has been applied. Experimental tests have been performed...

  4. Determination of the failure probability in the weld region of ap-600 vessel for transient condition

    International Nuclear Information System (INIS)

    Wahyono, I.P.

    1997-01-01

    Failure probability in the weld region of AP-600 vessel was determined for transient condition scenario. The type of transient is increase of the heat removal from primary cooling system due to sudden opening of safety valves or steam relief valves on the secondary cooling system or the steam generator. Temperature and pressure in the vessel was considered as the base of deterministic calculation of the stress intensity factor. Calculation of film coefficient of the convective heat transfers is a function of the transient time and water parameter. Pressure, material temperature, flaw depth and transient time are variables for the stress intensity factor. Failure probability consideration was done by using the above information in regard with the flaw and probability distributions of Octavia II and Marshall. Calculation of the failure probability by probability fracture mechanic simulation is applied on the weld region. Failure of the vessel is assumed as a failure of the weld material with one crack which stress intensity factor applied is higher than the critical stress intensity factor. VISA II code (Vessel Integrity Simulation Analysis II) was used for deterministic calculation and simulation. Failure probability of the material is 1.E-5 for Octavia II distribution and 4E-6 for marshall distribution for each transient event postulated. The failure occurred at the 1.7th menit of the initial transient under 12.53 ksi of the pressure

  5. Taipower's transient analysis methodology for pressurized water reactors

    International Nuclear Information System (INIS)

    Huang, Pinghue

    1998-01-01

    The methodology presented in this paper is a part of the 'Taipower's Reload Design and Transient Analysis Methodologies for Light Water Reactors' developed by the Taiwan Power Company (TPC) and the Institute of Nuclear Energy Research. This methodology utilizes four computer codes developed or sponsored by Electric Power Research institute: system transient analysis code RETRAN-02, core thermal-hydraulic analysis code COBRAIIIC, three-dimensional spatial kinetics code ARROTTA, and fuel rod evaluation code FREY. Each of the computer codes was extensively validated. Analysis methods and modeling techniques were conservatively established for each application using a systematic evaluation with the assistance of sensitivity studies. The qualification results and analysis methods were documented in detail in TPC topical reports. The topical reports for COBRAIIIC, ARROTTA. and FREY have been reviewed and approved by the Atomic Energy Council (ABC). TPC 's in-house transient methodology have been successfully applied to provide valuable support for many operational issues and plant improvements for TPC's Maanshan Units I and 2. Major applications include the removal of the resistance temperature detector bypass system, the relaxation of the hot-full-power moderator temperature coefficient design criteria imposed by the ROCAEC due to a concern on Anticipated Transient Without Scram, the reduction of boron injection tank concentration and the elimination of the heat tracing, and the reduction of' reactor coolant system flow. (author)

  6. PSH Transient Simulation Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-21

    PSH Transient Simulation Modeling presentation from the WPTO FY14 - FY16 Peer Review. Transient effects are an important consideration when designing a PSH system, yet numerical techniques for hydraulic transient analysis still need improvements for adjustable-speed (AS) reversible pump-turbine applications.

  7. Transients in reactors for power systems compensation

    Science.gov (United States)

    Abdul Hamid, Haziah

    This thesis describes new models and investigations into switching transient phenomena related to the shunt reactors and the Mechanically Switched Capacitor with Damping Network (MSCDN) operations used for reactive power control in the transmission system. Shunt reactors and MSCDN are similar in that they have reactors. A shunt reactor is connected parallel to the compensated lines to absorb the leading current, whereas the MSCDN is a version of a capacitor bank designed as a C-type filter for use in the harmonic-rich environment. In this work, models have been developed and transient overvoltages due to shunt reactor deenergisation were estimated analytically using MathCad, a mathematical program. Computer simulations used the ATP/EMTP program to reproduce both single-phase and three-phase shunt reactor switching at 275 kV operational substations. The effect of the reactor switching on the circuit breaker grading capacitor was also examined by considering various switching conditions.. The main original achievement of this thesis is the clarification of failure mechanisms occurring in the air-core filter reactor due to MSCDN switching operations. The simulation of the MSCDN energisation was conducted using the ATP/EMTP program in the presence of surge arresters. The outcome of this simulation shows that extremely fast transients were established across the air-core filter reactor. This identified transient event has led to the development of a detailed air-core reactor model, which accounts for the inter-turn RLC parameters as well as the stray capacitances-to-ground. These parameters are incorporated into the transient simulation circuit, from which the current and voltage distribution across the winding were derived using electric field and equivalent circuit modelling. Analysis of the results has revealed that there are substantial dielectric stresses imposed on the winding insulation that can be attributed to a combination of three factors. (i) First, the

  8. Lessons Learned from Applying Design Thinking in a NASA Rapid Design Study in Aeronautics

    Science.gov (United States)

    McGowan, Anna-Maria; Bakula, Casey; Castner, Raymond

    2017-01-01

    In late 2015, NASA's Aeronautics Research Mission Directorate (ARMD) funded an experiment in rapid design and rapid teaming to explore new approaches to solving challenging design problems in aeronautics in an effort to cultivate and foster innovation. This report summarizes several lessons learned from the rapid design portion of the study. This effort entailed learning and applying design thinking, a human-centered design approach, to complete the conceptual design for an open-ended design challenge within six months. The design challenge focused on creating a capability to advance experimental testing of autonomous aeronautics systems, an area of great interest to NASA, the US government as a whole, and an entire ecosystem of users and developers around the globe. A team of nine civil servant researchers from three of NASA's aeronautics field centers with backgrounds in several disciplines was assembled and rapidly trained in design thinking under the guidance of the innovation and design firm IDEO. The design thinking process, while used extensively outside the aerospace industry, is less common and even counter to many practices within the aerospace industry. In this report, several contrasts between common aerospace research and development practices and design thinking are discussed, drawing upon the lessons learned from the NASA rapid design study. The lessons discussed included working towards a design solution without a set of detailed design requirements, which may not be practical or even feasible for management to ascertain for complex, challenging problems. This approach allowed for the possibility of redesigning the original problem statement to better meet the needs of the users. Another lesson learned was to approach problems holistically from the perspective of the needs of individuals that may be affected by advances in topic area instead of purely from a technological feasibility viewpoint. The interdisciplinary nature of the design team also

  9. Computational model for transient studies of IRIS pressurizer behavior

    International Nuclear Information System (INIS)

    Rives Sanz, R.; Montesino Otero, M.E.; Gonzalez Mantecon, J.; Rojas Mazaira, L.

    2014-01-01

    International Reactor Innovative and Secure (IRIS) excels other Small Modular Reactor (SMR) designs due to its innovative characteristics regarding safety. IRIS integral pressurizer makes the design of larger pressurizer system than the conventional PWR, without any additional cost. The IRIS pressurizer volume of steam can provide enough margins to avoid spray requirement to mitigate in-surge transient. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial finite volume Computational Fluid Dynamic code CFX 14. A symmetric tridimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of three phases: liquid, steam, and vapor bubbles in liquid volume. Additionally, it takes into account the heat losses between the pressurizer and primary circuit. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX by using expressions in CFX Command Language (CCL) format. Moreover, several additional variables are defined for improving the convergence and allow monitoring of boron dilution sequences and condensation-evaporation rate in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences such as the in/out-surge transients and boron dilution sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  10. Evaluation of the Transient Eddy Current Potential Drop of a Four Point Probe

    Science.gov (United States)

    Bowler, J. R.

    2009-03-01

    The transient electrical potential drop of a four point probe has been calculated for the case where a current pulse is injected into a conductive plate via two surface contact electrodes and the voltage measured between two other contact electrodes. The four contact points can be co-linear but this is not always case. For example, they can form a rectangle. Usually such probes carry direct current or alternating current and are used to measure electrical conductivity, crack dimensions or variations of conductivity and magnetic permeability with depth. However, the advantage of a current pulse excitation is that information on the variations of material properties with depth can be acquired rapidly and conveniently. What is needed is a means to infer material properties such as the conductivity variations with depth from the transient field measurements. Here, as an initial step in developing this analysis, we report on the evaluation of transient potential drop signals for four point probes on a homogeneous conductive plates.

  11. Effect of thermal transients on the hardness of Zircaloy fuel cladding

    International Nuclear Information System (INIS)

    Hobson, D.O.

    1976-06-01

    This study is directed toward the determination of the effects of annealing cycles with rapid heating rates, short hold times at specific temperatures, and rapid cool-down rates on the hardness of Zircaloy fuel cladding. These rapid annealing cycles are designed to provide preliminary annealing behavior data on Loss-of-Fluid-Test Reactor cladding samples. Information has been obtained on (1) the time dependence of the hardness as a function of annealing temperature, and (2) a correlation of single- and multitransient annealing relationships. Both single- and triple-cycle transients were used; four hold times at each of five maximum temperatures comprised the data set (each portion of the triple-cycle experiments had isothermal hold times equal to one-third of their analogous single-cycle times). It was found that there was little difference in the hardness response between single- and triple-cycle transients for a given total hold time at a particular temperature. Test temperatures range from 1000 to 1400 0 F (538 to 760 0 C) and hold times from 5 to 135 sec. The 1100 0 F (593 0 C) level was found to be the transition level for hardness changes, with shorter times (5 and 15 sec) effecting little or no hardness decrease and the longer times (45 and 135 sec) producing partially and fully annealed material, respectively. Temperatures equal to or greater than 1300 0 F (704 0 C) resulted in fully annealed material for all hold times. The 1000 0 F (538 0 C) tests produced no measurable softening

  12. RApid Primary care Initiation of Drug treatment for Transient Ischaemic Attack (RAPID-TIA): study protocol for a pilot randomised controlled trial.

    Science.gov (United States)

    Edwards, Duncan; Fletcher, Kate; Deller, Rachel; McManus, Richard; Lasserson, Daniel; Giles, Matthew; Sims, Don; Norrie, John; McGuire, Graham; Cohn, Simon; Whittle, Fiona; Hobbs, Vikki; Weir, Christopher; Mant, Jonathan

    2013-07-02

    People who have a transient ischaemic attack (TIA) or minor stroke are at high risk of a recurrent stroke, particularly in the first week after the event. Early initiation of secondary prevention drugs is associated with an 80% reduction in risk of stroke recurrence. This raises the question as to whether these drugs should be given before being seen by a specialist--that is, in primary care or in the emergency department. The aims of the RAPID-TIA pilot trial are to determine the feasibility of a randomised controlled trial, to analyse cost effectiveness and to ask: Should general practitioners and emergency doctors (primary care physicians) initiate secondary preventative measures in addition to aspirin in people they see with suspected TIA or minor stroke at the time of referral to a specialist? This is a pilot randomised controlled trial with a sub-study of accuracy of primary care physician diagnosis of TIA. In the pilot trial, we aim to recruit 100 patients from 30 general practices (including out-of-hours general practice centres) and 1 emergency department whom the primary care physician diagnoses with TIA or minor stroke and randomly assign them to usual care (that is, initiation of aspirin and referral to a TIA clinic) or usual care plus additional early initiation of secondary prevention drugs (a blood-pressure lowering protocol, simvastatin 40 mg and dipyridamole 200 mg m/r bd). The primary outcome of the main study will be the number of strokes at 90 days. The diagnostic accuracy sub-study will include these 100 patients and an additional 70 patients in whom the primary care physician thinks the diagnosis of TIA is possible, rather than probable. For the pilot trial, we will report recruitment rate, follow-up rate, a preliminary estimate of the primary event rate and occurrence of any adverse events. For the diagnostic study, we will calculate sensitivity and specificity of primary care physician diagnosis using the final TIA clinic diagnosis as the

  13. Transient Osteoporosis of the Hip in Pregnancy: A Case Report - Case Report

    Directory of Open Access Journals (Sweden)

    Ayşe Ekim

    2009-08-01

    Full Text Available Transient osteoporosis of the hip is an uncommon disease, the cause is not known. This condition is reversible. Because generally the hip joint is effected it is named as “transient osteoporosis of the hip”. It is usually seen in women in the third trimester of pregnancy and in middle-aged men. The patients admitts with acute, severe, and progressive hip pain and these complaints are generally severe limiting their ambulations. Prognose of transient osteoporosis of the hip is good. In treatment; conservative treament approaches, bed rest is recommended and generally complaints are disappear in a few months. In this article; a case is presented which has applied with acut hip pain in one side, in the third trimester of pregnancy. The case has been diagnosed as transient osteoporosis of the hip according to clinical examination and radilogical investigation results. And cured with conservative approaches. (From the World of Osteoporosis 2009;15:48-51

  14. Study of the initiation of subcooled boiling during power transients

    International Nuclear Information System (INIS)

    VanVleet, R.J.

    1985-01-01

    An experimental investigation of boiling initiation during power transients has been conducted for horizontal-cylinder heating elements in degassed distilled water. Platinum elements, 0.127 and 0.250 mm in diameter, were internally heated electrically at a controlled superficial heat flux (power applied divided by surface area) increasing linearly with time at rates of 0.035 and 0.35 MW/m 2 s and corresponding test durations of 20 and 2 seconds. Tests were carried out at saturation temperatures from 100 to 195 0 C with bulk fluid subcooling from 0 to 30 K. During the course of a power transient, element temperature and superficial heat flux were measured electrically and the boiling initiation time was determined optically. It was found that the conditions for boiling initiation depended strongly on the pressure-temperature history of the heating element and surround fluid prior to the transient. Boiling initiation times were found to agree qualitatively with predictions of a model based on the contact-angle hysteresis concept. Brief prepressurization prior to a transient was found to increase dramatically the temperature and heat flux required for boiling initiation because of deactivation of boiling initiation sites. However, sites were re-activated during the transient and, in subsequent tests without prepressurization, no elevation in boiling initiation conditions was observed and results were in quantitative agreement with predictions of the model

  15. Determination of the diffusion coefficient of oxygen in sodium chloride solutions with a transient pulse technique

    NARCIS (Netherlands)

    van Stroe, A.J.; Janssen, L.J.J.

    1993-01-01

    An accurate and rapid method for detg. the diffusion coeffs. of electrochem. active gases in electrolytes is described. The technique is based on chronoamperometry where transient currents are measured and interpreted with a Cottrell-related equation. The diffusion coeffs. of oxygen were detd. for

  16. Physically Transient Memory on a Rapidly Dissoluble Paper for Security Application

    Science.gov (United States)

    Bae, Hagyoul; Lee, Byung-Hyun; Lee, Dongil; Seol, Myeong-Lok; Kim, Daewon; Han, Jin-Woo; Kim, Choong-Ki; Jeon, Seung-Bae; Ahn, Daechul; Park, Sang-Jae; Park, Jun-Young; Choi, Yang-Kyu

    2016-12-01

    We report the transient memory device by means of a water soluble SSG (solid sodium with glycerine) paper. This material has a hydroscopic property hence it can be soluble in water. In terms of physical security of memory devices, prompt abrogation of a memory device which stored a large number of data is crucial when it is stolen because all of things have identified information in the memory device. By utilizing the SSG paper as a substrate, we fabricated a disposable resistive random access memory (RRAM) which has good data retention of longer than 106 seconds and cycling endurance of 300 cycles. This memory device is dissolved within 10 seconds thus it can never be recovered or replicated. By employing direct printing but not lithography technology to aim low cost and disposable applications, the memory capacity tends to be limited less than kilo-bits. However, unlike high memory capacity demand for consumer electronics, the proposed device is targeting for security applications. With this regards, the sub-kilobit memory capacity should find the applications such as one-time usable personal identification, authentication code storage, cryptography key, and smart delivery tag. This aspect is attractive for security and protection system against unauthorized accessibility.

  17. Transient analysis for alternating over-current characteristics of HTSC power transmission cable

    Science.gov (United States)

    Lim, S. H.; Hwang, S. D.

    2006-10-01

    In this paper, the transient analysis for the alternating over-current distribution in case that the over-current was applied for a high-TC superconducting (HTSC) power transmission cable was performed. The transient analysis for the alternating over-current characteristics of HTSC power transmission cable with multi-layer is required to estimate the redistribution of the over-current between its conducting layers and to protect the cable system from the over-current in case that the quench in one or two layers of the HTSC power cable happens. For its transient analysis, the resistance generation of the conducting layers for the alternating over-current was reflected on its equivalent circuit, based on the resistance equation obtained by applying discrete Fourier transform (DFT) for the voltage and the current waveforms of the HTSC tape, which comprises each layer of the HTSC power transmission cable. It was confirmed through the numerical analysis on its equivalent circuit that after the current redistribution from the outermost layer into the inner layers first happened, the fast current redistribution between the inner layers developed as the amplitude of the alternating over-current increased.

  18. An analysis of power transients observed in SPERT I reactors

    International Nuclear Information System (INIS)

    Clancy, B.E.; Connolly, J.W.; Harrington, B.V.

    1976-04-01

    The analytical method described in Part I of this series has been applied to the calculation of spert I transients performed with higher initial moderator temperatures and also to those performed in a highly undermoderated core. Reasonable agreement has been obtained between calculated and experimental burst data. (author)

  19. Preliminary Assessment of Transient of Over Power Accident for DSFR-600

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Andong; Bae, Moohoon; Suh, Namduk [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    TRACE code was selected as one of candidates for audit code, so sodium properties and heat transfer model in the code was verified first. On the basis of MARS-LMR code input, DSFR-600 TRACE model was developed and applied to PHTS tube rupture case, one of design base events (DBE) of DSFR-600. In this study, Transients of Over Power (TOP) event is assessed using TRACE code as one another case of DBEs of DSFR-600 for preparation of audit calculation of PGSFR.One of the design base events, transients of over power of Demonstration Sodium cooled Fast Reactor was simulated using TRACE code. Predicted fuel temperature showed that the peak fuel temperature occurs when the reactor scrammed and predicted temperature was similar to the MARS-LMRs assessment by KAERI. In this study, it is found that the second peak of fuel temperature is influenced by the inventory of steam generator and the natural circulation characteristic of the reactor vessel pool. Pre-calculation of the unprotected transients of over power with conservative reactivity assumption showed that this assumption is conservative in design base even assessment. However the method of measurement and applying the core radial, fuel and control rod axial expansion reactivity feedback is crucial in BDBE assessment of SFR.

  20. Analysis and calibration of transient enhanced diffusion for an indium impurity in a nanoscale semiconductor device

    International Nuclear Information System (INIS)

    Lee, Jun-Ha; Lee, Hoong-Joo

    2005-01-01

    We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO 2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-μm device characteristics, such as V th and I dsat , for which the differences between simulation and experiment less than 5 %.

  1. A FRAMEWORK FOR INTERPRETING FAST RADIO TRANSIENTS SEARCH EXPERIMENTS: APPLICATION TO THE V-FASTR EXPERIMENT

    International Nuclear Information System (INIS)

    Trott, Cathryn M.; Tingay, Steven J.; Wayth, Randall B.; Macquart, Jean-Pierre R.; Palaniswamy, Divya; Thompson, David R.; Wagstaff, Kiri L.; Majid, Walid A.; Burke-Spolaor, Sarah; Deller, Adam T.; Brisken, Walter F.

    2013-01-01

    We define a framework for determining constraints on the detection rate of fast transient events from a population of underlying sources, with a view to incorporate beam shape, frequency effects, scattering effects, and detection efficiency into the metric. We then demonstrate a method for combining independent data sets into a single event rate constraint diagram, using a probabilistic approach to the limits on parameter space. We apply this new framework to present the latest results from the V-FASTR experiment, a commensal fast transients search using the Very Long Baseline Array (VLBA). In the 20 cm band, V-FASTR now has the ability to probe the regions of parameter space of importance for the observed Lorimer and Keane fast radio transient candidates by combining the information from observations with differing bandwidths, and properly accounting for the source dispersion measure, VLBA antenna beam shape, experiment time sampling, and stochastic nature of events. We then apply the framework to combine the results of the V-FASTR and Allen Telescope Array Fly's Eye experiments, demonstrating their complementarity. Expectations for fast transients experiments for the SKA Phase I dish array are then computed, and the impact of large differential bandwidths is discussed.

  2. Transient sensitivity to nisin in cold-shocked Gram negatives.

    Science.gov (United States)

    Boziaris, I S; Adams, M R

    2000-09-01

    Rapid chilling in the presence of nisin caused a dose-dependent reduction in the populations of several Gram-negative bacteria, despite the fact that appreciable structural injury to the outer membrane was not detected. Pseudomonas aeruginosa was most affected, followed by Pseudomonas fragi, Salmonella enteritidis PT4, PT7 and Escherichia coli, respectively. Addition of nisin after the chilling treatment had no effect. The results are ascribed to a transient susceptibility caused by phase changes in the lipids associated with the outer membrane, which are rapidly reversed when the cells return to higher temperatures. Combinations of chilling shock, nisin and EDTA gave much lower reductions of Salmonella and Pseudomonas on chicken skin in comparison with broths. This is attributed to a buffering of the temperature shock experienced by adherent bacteria and binding of the nisin by food particles.

  3. Transient current induced in thin film diamonds by swift heavy ions

    International Nuclear Information System (INIS)

    Sato, Shin-ichiro; Makino, Takahiro; Ohshima, Takeshi; Kamiya, Tomihiro; Kada, Wataru

    2017-01-01

    Single crystal diamond is a suitable material for the next generation particle detectors because of the superior electrical properties and the high radiation tolerance. In order to investigate charge transport properties of diamond particle detectors, transient currents generated in diamonds by single swift heavy ions (26 MeV O 5+ and 45 MeV Si 7+ ) are investigated. We also measured two dimensional maps of transient currents by single ion hits. In the case of 50 μm-thick diamond, both the signal height and the collected charge are reduced by the subsequent ion hits and the charge collection time is extended. Our results are thought to be attributable to the polarization effect in diamond and it appears only when the transient current is dominated by hole current. In the case of 6 μm-thick diamond membrane, an “island” structure is found in the 2D map of transient currents. Signals in the islands shows different applied bias dependence from signals in other regions, indicating different crystal and/or metal contact quality. Simulation study of transient currents based on the Shockley-Ramo theorem clarifies that accumulation of space charges changes distribution of electric field in diamond and causes the polarization effect.

  4. Methods for transient assay of gene function in floral tissues

    Directory of Open Access Journals (Sweden)

    Pathirana Nilangani N

    2007-01-01

    Full Text Available Abstract Background There is considerable interest in rapid assays or screening systems for assigning gene function. However, analysis of gene function in the flowers of some species is restricted due to the difficulty of producing stably transformed transgenic plants. As a result, experimental approaches based on transient gene expression assays are frequently used. Biolistics has long been used for transient over-expression of genes of interest, but has not been exploited for gene silencing studies. Agrobacterium-infiltration has also been used, but the focus primarily has been on the transient transformation of leaf tissue. Results Two constructs, one expressing an inverted repeat of the Antirrhinum majus (Antirrhinum chalcone synthase gene (CHS and the other an inverted repeat of the Antirrhinum transcription factor gene Rosea1, were shown to effectively induce CHS and Rosea1 gene silencing, respectively, when introduced biolistically into petal tissue of Antirrhinum flowers developing in vitro. A high-throughput vector expressing the Antirrhinum CHS gene attached to an inverted repeat of the nos terminator was also shown to be effective. Silencing spread systemically to create large zones of petal tissue lacking pigmentation, with transmission of the silenced state spreading both laterally within the affected epidermal cell layer and into lower cell layers, including the epidermis of the other petal surface. Transient Agrobacterium-mediated transformation of petal tissue of tobacco and petunia flowers in situ or detached was also achieved, using expression of the reporter genes GUS and GFP to visualise transgene expression. Conclusion We demonstrate the feasibility of using biolistics-based transient RNAi, and transient transformation of petal tissue via Agrobacterium infiltration to study gene function in petals. We have also produced a vector for high throughput gene silencing studies, incorporating the option of using T-A cloning to

  5. Transient flow combustion

    Science.gov (United States)

    Tacina, R. R.

    1984-01-01

    Non-steady combustion problems can result from engine sources such as accelerations, decelerations, nozzle adjustments, augmentor ignition, and air perturbations into and out of the compressor. Also non-steady combustion can be generated internally from combustion instability or self-induced oscillations. A premixed-prevaporized combustor would be particularly sensitive to flow transients because of its susceptability to flashback-autoignition and blowout. An experimental program, the Transient Flow Combustion Study is in progress to study the effects of air and fuel flow transients on a premixed-prevaporized combustor. Preliminary tests performed at an inlet air temperature of 600 K, a reference velocity of 30 m/s, and a pressure of 700 kPa. The airflow was reduced to 1/3 of its original value in a 40 ms ramp before flashback occurred. Ramping the airflow up has shown that blowout is more sensitive than flashback to flow transients. Blowout occurred with a 25 percent increase in airflow (at a constant fuel-air ratio) in a 20 ms ramp. Combustion resonance was found at some conditions and may be important in determining the effects of flow transients.

  6. Most-Critical Transient Disturbances in an Incompressible Flat-Plate Boundary Layer

    Science.gov (United States)

    Monschke, Jason; White, Edward

    2015-11-01

    Transient growth is a linear disturbance growth mechanism that plays a key role in roughness-induced boundary-layer transition. It occurs when superposed stable, non-orthogonal continuous spectrum modes experience algebraic disturbance growth followed by exponential decay. Algebraic disturbance growth can modify the basic state making it susceptible to secondary instabilities rapidly leading to transition. Optimal disturbance theory was developed to model the most-dangerous disturbances. However, evidence suggests roughness-induced transient growth is sub-optimal yet leads to transition earlier than optimal theory suggests. This research computes initial disturbances most unstable to secondary instabilities to further develop the applicability of transient growth theory to surface roughness. The main approach is using nonlinear adjoint optimization with solutions of the parabolized Navier-Stokes and BiGlobal stability equations. Two objective functions were considered: disturbance kinetic energy growth and sinuous instability growth rate. The first objective function was used as validation of the optimization method. Counter-rotating streamwise vortices located low in the boundary layer maximize the sinuous instability growth rate. The authors would like to acknowledge NASA and the AFOSR for funding this work through AFOSR Grant FA9550-09-1-0341.

  7. Identification of speech transients using variable frame rate analysis and wavelet packets.

    Science.gov (United States)

    Rasetshwane, Daniel M; Boston, J Robert; Li, Ching-Chung

    2006-01-01

    Speech transients are important cues for identifying and discriminating speech sounds. Yoo et al. and Tantibundhit et al. were successful in identifying speech transients and, emphasizing them, improving the intelligibility of speech in noise. However, their methods are computationally intensive and unsuitable for real-time applications. This paper presents a method to identify and emphasize speech transients that combines subband decomposition by the wavelet packet transform with variable frame rate (VFR) analysis and unvoiced consonant detection. The VFR analysis is applied to each wavelet packet to define a transitivity function that describes the extent to which the wavelet coefficients of that packet are changing. Unvoiced consonant detection is used to identify unvoiced consonant intervals and the transitivity function is amplified during these intervals. The wavelet coefficients are multiplied by the transitivity function for that packet, amplifying the coefficients localized at times when they are changing and attenuating coefficients at times when they are steady. Inverse transform of the modified wavelet packet coefficients produces a signal corresponding to speech transients similar to the transients identified by Yoo et al. and Tantibundhit et al. A preliminary implementation of the algorithm runs more efficiently.

  8. Stress state dependence of transient irradiation creep in 20% cold worked 316 stainless steel

    International Nuclear Information System (INIS)

    Foster, J.P.; Gilbert, E.R.

    1998-01-01

    Irradiation creep tests were performed in fast reactors using the stress states of uniaxial tension, biaxial tension, bending and torsion. In order to compare the saturated transient strain irradiation creep component, the test data were converted to equivalent strain and equivalent stress. The saturated transient irradiation creep component was observed to depend on the stress state. The highest value was exhibited by the uniaxial tension stress state, and the lowest by the torsion stress state. The biaxial tension and bending stress state transient component values were intermediate. This behavior appears to be related to the dislocation or microscopic substructure resulting from fabrication processing and the applied stress direction. (orig.)

  9. Measurement of the Air Chance Rate and Ventilation Characteristics During Short Term Transient Phenomena

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Perino, M.

    2004-01-01

    Different measurement procedures are available for the experimental assessment of air change rates inside ventilated enclosures. These mainly consist of tracer gas techniques and can usually be applied to steady-state or moderately transient conditions and when a continous mixing of the indoor air...... ventilation. The results are critically compared with the air flow rates assessed through anemometric measurements. The measurement features, limitations, shortcomings and uncertainties are also discussed....... is assured throughout the test. However, due to the relatively slow response of the gas analysers, none of these procedures can usually be applied to fast transient phenomena that last 15 minutes or less. Moreover in many cases of natural ventilation strategies, the continuous mixing of the indoor air would...

  10. PRETTA:A COMPUTER PROGRAM FOR PWR PRESSURIZER’S TRANSIENT THERMODYNAMICS

    Institute of Scientific and Technical Information of China (English)

    阿谢德; 徐济鋆

    2001-01-01

    A computer program PRETTA “Pressurizer Transient Thermodynamics Analysis” was developed for the prediction of pressurizer under transient conditions. It is based on the solution of the conservation laws of heat and mass applied to the three separate and non equilibrium thermodynamic regions. In the program all of the important thermal-hydraulics phenomena occurring in the pressurizer: stratification of the hot water and incoming cold water, bulk flashing and condensation, wall condensation, and interfacial heat and mass transfer have been considered. The bubble rising and rain-out models are developed to describe bulk flashing and condensation, respectively. To obtain the wall condensation rate, a one-dimensional heat conduction equation is solved by the pivoting method. The presented computer program will predict the pressure-time behavior of a PWR pressurizer during a variety of transients. The results obtained from the proposed mathematical model are in good agreement with available data on the CHASHMA nuclear power plant's pressurizer performance.

  11. Proceedings of a specialist meeting on boron reactivity transients

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    The CSNI Specialist Meeting on Boron Dilution Reactivity Transients was hosted by the Penn State University in collaboration with the US Nuclear Regulatory Commission and the TRAC Users Group. More than 70 experts from 12 OECD countries, as well as experts from Russia and other non-OECD countries attended the meeting. Thirty papers were presented in five technical sessions. The purpose of the meeting was to bring together experts involved in the different activities related to boron dilution transients. The experts came from all involved parties, including research organizations, regulatory authorities, vendors and utilities. Information was openly shared and discussed on the experimental results, plant and systems analysis, numerical analysis of mixing and probability and consequences of these transients. Regulatory background and licensing implications were also included to provide the proper frame work for the technical discussion. Each of these areas corresponded to a separate session. The meeting focused on the thermal-hydraulic aspects because of the current interest in that subject and the significant amount of new technical information being generated. Three papers of the same conference are already available in INIS as individual reports: Potential for boron dilution during small-break LOCAs in PWRs (Ref. number: 27029412); Analysis of boron dilution in a four-loop PWR (Ref. number: 27051651); Probability and consequences of a rapid boron dilution sequence in a PWR (Ref. number: 27029411)

  12. Code Coupling for Multi-Dimensional Core Transient Analysis

    International Nuclear Information System (INIS)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il

    2015-01-01

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident

  13. Code Coupling for Multi-Dimensional Core Transient Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il [KEPCO NF, Daejeon (Korea, Republic of)

    2015-05-15

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident.

  14. Applying of the array transducers' technology for surface acoustic waves materials characterization in the transient regime

    International Nuclear Information System (INIS)

    Frenet, D.

    2000-01-01

    In this document we present a theoretical and experimental study which has been led to design a surface acoustic wave device for local characterisation (relatively to the wavelength) of isotropic or anisotropic materials. The device is based on a phased-array transducer of conical shape we have specifically designed for this purpose. It operates in the impulsive mode, in the frequency range of 1-5 MHz. In order to deduce mechanical properties of the material, it is possible to measure the surface wave characteristics (velocity, attenuation,...). Different methods for measuring the wave velocity have been developed taking advantage of from the phased-array technology. The originality of theses methods relies on the fact that the measures are performed without moving the transducer. Consequently, the device requires no additional mechanical system and it is quite compact. In addition, this shortens the characterisation process duration comparatively to the usually available methods (e. g. the V(z) technique). In the theoretical section of this study, a versatile model allowing to simulate in the time harmonic regime as well as in the transient regime, the transmitted field, the field reflected on isotropic or anisotropic planar samples and the output voltage for transducers of arbitrary shapes has been developed. The model has been applied to the phased-array conical transducer as well as to more classical transducers such as planar (rectangular) or focusing (spherically or cylindrically shaped) transducers. It predicts not only the geometrical contributions of the reflected field and signal but also the leaky contributions related to the surface acoustic waves. (author)

  15. Modeling and analysis of thermal-hydraulic response of uranium-aluminum reactor fuel plates under transient heatup conditions

    Energy Technology Data Exchange (ETDEWEB)

    Navarro-Valenti, S.; Kim, S.H.; Georgevich, V. [Oak Ridge National Lab., TN (United States)] [and others

    1995-09-01

    The purpose of this paper is to describe the analysis performed to predict the thermal behavior of fuel miniplates under rapid transient heatup conditions. The possibility of explosive boiling was considered, and it was concluded that the heating rates are not large enough for explosive boiling to occur. However, transient boiling effects were pronounced. Because of the complexity of transient pool boiling and the unavailability of experimental data for the situations studied, an approximation was made that predicted the data very well within the uncertainties present. If pool boiling from the miniplates had been assumed to be steady during the heating pulse, the experimental data would have been greatly overestimated. This fact demonstrates the importance of considering the transient nature of heat transfer in the analysis of reactivity excursion accidents. An additional contribution of the present work is that it provided data on highly subcooled steady nulceate boiling from the cooling portion of the thermocouple traces.

  16. Optimal Subinterval Selection Approach for Power System Transient Stability Simulation

    Directory of Open Access Journals (Sweden)

    Soobae Kim

    2015-10-01

    Full Text Available Power system transient stability analysis requires an appropriate integration time step to avoid numerical instability as well as to reduce computational demands. For fast system dynamics, which vary more rapidly than what the time step covers, a fraction of the time step, called a subinterval, is used. However, the optimal value of this subinterval is not easily determined because the analysis of the system dynamics might be required. This selection is usually made from engineering experiences, and perhaps trial and error. This paper proposes an optimal subinterval selection approach for power system transient stability analysis, which is based on modal analysis using a single machine infinite bus (SMIB system. Fast system dynamics are identified with the modal analysis and the SMIB system is used focusing on fast local modes. An appropriate subinterval time step from the proposed approach can reduce computational burden and achieve accurate simulation responses as well. The performance of the proposed method is demonstrated with the GSO 37-bus system.

  17. Transient evaluation for LPG and oil pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Meliande, Patricia; Do Nascimento, Elson Antonio; Fernandes Lacerda, Rogerio [Federal Fluminense University, Niteroi, RJ (Brazil)

    2010-07-01

    In the last decades, the offshore industry has expanded thanks to the development of equipment for subsea operation. In such installations, protection equipment can be adapted to the installation's design in order to avoid surge pressure effects and ensure safety and integrity of the system, predicting transient effect is therefore very important. The purpose of this study is to predict the surge pressure on refrigerated LPG and gasoline pipelines during unpredicted closure of valves. Flowmaster software was used to carry out the simulations and its results were then validated with a methodology that applied the characteristics method based on Wylie and Streeter assumptions. Results showed that surge pressures during transient effect for both refrigerated LPG and Gasoline pipeline systems were less than the maximum allowable operating pressure and therefore no control dispositive installations are geeded. This study showed that the use of these computer models can ensure the optimization of the system and provide cost effective solutions.

  18. A transient model to the thermal detonation

    International Nuclear Information System (INIS)

    Karachalios, K.

    1987-04-01

    The model calculates the escalation dynamics and the long time behavior of thermal detonation waves depending on the initial and boundary conditions (data of the premixture, ignition at a solid wall or at an open end, etc.). Especially, for a given mixture and a certain fragmentation behavior more than one stable steady-state cases resulted, depending on the applied ignition energy. Investigations showed a very good consistency between the transient model and a steady-state model which is based on the same physical description and includes an additional stability criterion. Also the influence of effects such as e.g. non-homogeneous coolant heating, spherical instead of plane wave propagation and inhomogeneities of the premixture on the development of the wave were investigated. Comparison calculations with large scale experiments showed that they can be well explained by means of the thermal detonation theory, especially considering the transient phase of the wave development. (orig./HP) [de

  19. Transient flow analysis of integrated valve opening process

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xinming; Qin, Benke; Bo, Hanliang, E-mail: bohl@tsinghua.edu.cn; Xu, Xingxing

    2017-03-15

    Highlights: • The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the integrated valve (IV) is the key control component. • The transient flow experiment induced by IV is conducted and the test results are analyzed to get its working mechanism. • The theoretical model of IV opening process is established and applied to get the changing rule of the transient flow characteristic parameters. - Abstract: The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the IV is the key control component. The working principle of integrated valve (IV) is analyzed and the IV hydraulic experiment is conducted. There is transient flow phenomenon in the valve opening process. The theoretical model of IV opening process is established by the loop system control equations and boundary conditions. The valve opening boundary condition equation is established based on the IV three dimensional flow field analysis results and the dynamic analysis of the valve core movement. The model calculation results are in good agreement with the experimental results. On this basis, the model is used to analyze the transient flow under high temperature condition. The peak pressure head is consistent with the one under room temperature and the pressure fluctuation period is longer than the one under room temperature. Furthermore, the changing rule of pressure transients with the fluid and loop structure parameters is analyzed. The peak pressure increases with the flow rate and the peak pressure decreases with the increase of the valve opening time. The pressure fluctuation period increases with the loop pipe length and the fluctuation amplitude remains largely unchanged under different equilibrium pressure conditions. The research results lay the base for the vibration reduction analysis of the CRHDS.

  20. Static converters power supply: transient regimes; Alimentation par convertisseurs statiques: regimes transitoires

    Energy Technology Data Exchange (ETDEWEB)

    Pasqualini, G. [Ecole Superieure d`Electricite (France)

    1997-08-01

    Direct current motors, asynchronous and variable speed synchronous motors are generally supplied with static converters. Speed variation is obtained by voltage variation in DC motors and by frequency variation in AC motors. In these conditions, these motors are running continuously in transient regimes: the DC motors current is not direct and the AC motors current is not sinusoidal. This situation leads to pulsing couples in the shaft line and to an increase of Joule effect losses. The aim of this paper is to present the methods of study of the electric motors functioning using the shape of the power voltages given by converters and mathematical models of these machines. The synchronous machines are rapidly described while the asynchronous machines are studied using Ku`s transformation instead of Park`s transformation for simplification. For each type of machine, calculation methods allow to determine their current, additional losses and couple characteristics. The transient regimes considered are those remaining when the motor is running at a constant speed and defined regime (supply voltages are periodical functions of time). These transient regimes are identically reproducing with a frequency which is a multiple of the converters supply frequency. Transient regimes due to functioning changes of the motor, such as resisting couple or power supply frequency variations, are not considered in this study. (J.S.) 9 refs.

  1. The use of single-crystal iron frames in transient field measurements

    International Nuclear Information System (INIS)

    Zalm, P.C.; Laan, J. van der; Middelkoop, G. van

    1979-01-01

    Single-crystal Fe frames have been investigated for use as a ferromagnetic backing in transient magnetic field experiments. For this purpose the surface magnetization as a function of applied magnetic field has been determined with the magneto-optical Kerr effect. The frames, which have two sides parallel to the crystal axis, can be fully magnetized at low external fields such that fringing fields are negligibly small. These single-crystal Fe backings have been used in several transient magnetic field experiments. Comparison of the measured precession angles with previous results, obtained in polycrystalline Fe foils at high external magnetic fields, shows that the single-crystal backings are satisfactory. After extended periods of heavy-ion bombardment the crystals exhibited no radiation damage effects. The absence of fringing fields leads to a reduction of a factor of four in the measuring time for transient field experiments. (Auth.)

  2. Transport properties of triarylamine based dendrimers studied by space charge limited current transients

    Science.gov (United States)

    Szymanski, Marek Z.; Kulszewicz-Bajer, Irena; Faure-Vincent, Jérôme; Djurado, David

    2012-08-01

    We have studied hole transport in triarylamine based dendrimer using space-charge-limited current transient technique. A mobility of 8 × 10-6 cm2/(V s) and a characteristic detrapping time of about 100 ms have been obtained. We found that quasi-ohmic contact is formed with gold. The obtained mobility differs from the apparent one given by the analysis of stationary current-voltage characteristics because of a limited contact efficiency. The comparison between transients obtained from fresh and aged samples reveals no change in mobility with aging. The deterioration of electrical properties is exclusively caused by trap formation and accumulation of ionic conducting impurities. Finally, repeated transient measurements have been applied to analyze the dynamics of charge trapping process.

  3. Thermonuclear model for high energy transients

    International Nuclear Information System (INIS)

    Woosley, S.E.

    1982-01-01

    The thermonuclear model for x- and γ-ray bursts is discussed. Different regimes of nuclear burning are reviewed, each appropriate to a given range of (steady state) accretion rate. Accretion rates in the range 10 -14 to 10 -8 Msub solar y -1 all appear capable of producing x-ray transients of various durations and intervals. Modifications introduced by radiatively driven mass loss, the thermal inertia of the envelope, different burning mechanisms, and two-dimensional considerations are discussed as are difficulties encountered when the thermonuclear model is confronted with observations of rapidly recurrent bursts (less than or equal to 10 min), and super-Eddington luminosities and temperatures. Results from a numerical simulation of a combined hydrogen-helium runaway initiated at pycnonuclear density are presented for the first time. The thermonuclear model for γ-ray bursts is also reviewed and updated, particularly with regard to the breakdown of the steady state hypothesis employed in previous work. Solely on the basis of nuclear instability, γ-ray bursts of various types appear possible for a very broad variety of accretion rates (approx. 10 -17 to approx. 10 -11 Msub solar y -1 ) although other considerations may restrict this range. The thermonuclear model appears capable of yielding a great diversity of high energy transient phenomena for various accretion rates, magnetic field configurations, and neutron star envelope histories

  4. Relaxation process of coherent transients in the presence of an adjacent strongly driven transition

    International Nuclear Information System (INIS)

    Feng Xiaomin; Yang Lijun; Li Xiaoli; Zhang Lianshui; Han Li; Guo Qinglin; Fu Guangsheng

    2007-01-01

    Coherent transient occurs when a two-level transition is subjected to pulsed laser excitation. The relaxation process of coherent transient depends on both the longitudinal and transverse relaxation parameters of the two-level transition, which is related to the population and coherence decay rates. In this paper we study relaxation process of a new type coherent transients observed by applying a pulsed laser excitation to a two-level transition in the presence of a second strong continuous-wave (cw) coherent field coupling one of the two levels to a third level, that is, in a three-level double-resonance configuration. The relaxation process of coherent transients is studied as a function of relaxation parameters of both the two-level transition excited by the pulsed laser field and the transition coupled by the cw laser field. It is shown that by involving a third level with coherent field the relaxation process of coherent transients of a two-level transition can be modified. Our study illustrates a new way of controlling relaxation process of coherent transients in a two-level transition by a second coherent laser and this has important implication for quantum information storage and quantum computing

  5. Utilizing elements of the CSAU phenomena identification and ranking table (PIRT) to qualify a PWR non-LOCA transients system code

    Energy Technology Data Exchange (ETDEWEB)

    Greene, K.R.; Fletcher, C.D.; Gottula, R.C.; Lindquist, T.R.; Stitt, B.D. [Framatome ANP, Richland, WA (United States)

    2001-07-01

    Licensing analyses of Nuclear Regulatory Commission (NRC) Standard Review Plan (SRP) Chapter 15 non-LOCA transients are an important part of establishing operational safety limits and design limits for nuclear power plants. The applied codes and methods are generally qualified using traditional methods of benchmarking and assessment, sample problems, and demonstration of conservatism. Rigorous formal methods for developing code and methodology have been created and applied to qualify realistic methods for Large Break Loss-of-Coolant Accidents (LBLOCA's). This methodology, Code Scaling, Applicability, and Uncertainty (CSAU), is a very demanding, resource intensive, process to apply. It would be challenging to apply a comprehensive and complete CSAU level of analysis, individually, to each of the more than 30 non-LOCA transients that comprise Chapter 15 events. However, certain elements of the process can be easily adapted to improve quality of the codes and methods used to analyze non- LOCA transients. One of these elements is the Phenomena Identification and Ranking Table (PIRT). This paper presents the results of an informally constructed PIRT that applies to non-LOCA transients for Pressurized Water Reactors (PWR's) of the Westinghouse and Combustion Engineering design. A group of experts in thermal-hydraulics and safety analysis identified and ranked the phenomena. To begin the process, the PIRT was initially performed individually by each expert. Then through group interaction and discussion, a consensus was reached on both the significant phenomena and the appropriate ranking. The paper also discusses using the PIRT as an aid to qualify a 'conservative' system code and methodology. Once agreement was obtained on the phenomena and ranking, the table was divided into six functional groups, by nature of the transients, along the same lines as Chapter 15. Then, assessment and disposition of the significant phenomena was performed. The PIRT and

  6. Transient Performance Improvement Circuit (TPIC)s for DC-DC converter applications

    Science.gov (United States)

    Lim, Sungkeun

    of the slow inductor current slew rate which is determined by the input voltage, output voltage, and the inductance. The remaining inductor current in the power delivery path will charge the output capacitors and develop a voltage across the ESR. As a result, large output voltage spikes occur during load current transients. Due to their limited control bandwidth, traditional VRs can not sufficiently respond rapidly to certain load transients. As a result, a large output voltage spike can occur during load transients, hence requiring a large amount of bulk capacitance to decouple the VR from the load [2]. If the remaining inductor current is removed from the power stage or the inductor current slew rate is changed, the output voltage spikes can be clamped, allowing the output capacitance to be reduced. A new design methodology for a Transient Performance Improvement Circuit(TPIC) based on controlling the output impedance of a regulator is presented. The TPIC works in parallel with a voltage regulator (VR)'s ceramic capacitors to achieve faster voltage regulation without the need for a large bulk capacitance, and can serve as a replacement for bulk capacitors. The specific function of the TPIC is to mimic the behavior of the bulk capacitance in a traditional VRM by sinking and sourcing large currents during transients, allowing the VR to respond quickly to current transients without the need for a large bulk capacitance. This will allow fast transient response without the need for a large bulk capacitor. The main challenge in applying the TPIC is creating a design which will not interfere with VR operation. A TPIC for a 4 Switch Buck-Boost (4SBB) converter is presented which functions by con- trolling the inductor current slew rate during load current transients. By increasing the inductor current slew rate, the remaining inductor current can be removed from the 4SBB power delivery path and the output voltage spike can be clamped. A second TPIC is presented which is

  7. Transient gas flow through layered porous media

    International Nuclear Information System (INIS)

    Morrison, F.A. Jr.

    1975-01-01

    Low Reynolds number isothermal flow of an ideal gas through layered porous material was investigated analytically. Relations governing the transient flow in one dimension are obtained. An implicit, iterative, unconditionally stable finite difference scheme is developed for calculation of such flows. A computer code, SIROCCO, employing this technique has been written and implemented on the LLL computer system. A listing of the code is included. This code may be effectively applied to the evaluation of stemming plans for underground nuclear experiments. (U.S.)

  8. Persistent and transient cost efficiency—an application to the Swiss hydropower sector

    International Nuclear Information System (INIS)

    Filippini, Massimo; University of Lugano; Geissmann, Thomas; Massachusetts Institute of Technology; Greene, William H.

    2017-01-01

    Electricity prices on the European market have decreased significantly over the past few years, resulting in a deterioration of Swiss hydropower firms’ competitiveness and profitability. One option to improve the sector’s competitiveness is to increase cost efficiency. The goal of this study is to quantify the level of persistent and transient cost efficiency of individual firms by applying the generalized true random effects (GTRE) model introduced by Colombi et al. (Journal of Productivity Analysis 42(2): 123–136, 2014) and Filippini and Greene (Journal of Productivity Analysis 45(2): 187–196, 2016). Applying this newly developed GTRE model to a total cost function, the level of cost efficiency of 65 Swiss hydropower firms is analyzed for the period between 2000 and 2013. A true random effects specification is estimated as a benchmark for the transient level of cost efficiency. The results show the presence of both transient as well as persistent cost inefficiencies. The GTREM predicts the aggregate level of cost inefficiency to amount to 21.8% (8.0% transient, 13.8% persistent) on average between 2000 and 2013. These two components differ in interpretation and implication. From an individual firm’s perspective, the two types of cost inefficiencies might require a firm’s management to respond with different improvement strategies. The existing level of persistent inefficiency could prevent the hydropower firms from adjusting their production processes to new market environments. From a regulatory point of view, the results of this study could be used in the scope and determination of the amount of financial support given to struggling firms.

  9. Improved lumped models for transient combined convective and radiative cooling of multi-layer composite slabs

    International Nuclear Information System (INIS)

    An Chen; Su Jian

    2011-01-01

    Improved lumped parameter models were developed for the transient heat conduction in multi-layer composite slabs subjected to combined convective and radiative cooling. The improved lumped models were obtained through two-point Hermite approximations for integrals. Transient combined convective and radiative cooling of three-layer composite slabs was analyzed to illustrate the applicability of the proposed lumped models, with respect to different values of the Biot numbers, the radiation-conduction parameter, the dimensionless thermal contact resistances, the dimensionless thickness, and the dimensionless thermal conductivity. It was shown by comparison with numerical solution of the original distributed parameter model that the higher order lumped model (H 1,1 /H 0,0 approximation) yielded significant improvement of average temperature prediction over the classical lumped model. In addition, the higher order (H 1,1 /H 0,0 ) model was applied to analyze the transient heat conduction problem of steel-concrete-steel sandwich plates. - Highlights: → Improved lumped models for convective-radiative cooling of multi-layer slabs were developed. → Two-point Hermite approximations for integrals were employed. → Significant improvement over classical lumped model was achieved. → The model can be applied to high Biot number and high radiation-conduction parameter. → Transient heat conduction in steel-concrete-steel sandwich pipes was analyzed as an example.

  10. Transients: The regulator's view

    International Nuclear Information System (INIS)

    Sheron, B.W.; Speis, T.P.

    1984-01-01

    This chapter attempts to clarify the basis for the regulator's concerns for transient events. Transients are defined as both anticipated operational occurrences and postulated accidents. Recent operational experience, supplemented by improved probabilistic risk analysis methods, has demonstrated that non-LOCA transient events can be significant contributors to overall risk. Topics considered include lessons learned from events and issues, the regulations governing plant transients, multiple failures, different failure frequencies, operator errors, and public pressure. It is concluded that the formation of Owners Groups and Regulatory Response Groups within the owners groups are positive signs of the industry's concern for safety and responsible dealing with the issues affecting both the US NRC and the industry

  11. Minimum depth of investigation for grounded-wire TEM due to self-transients

    Science.gov (United States)

    Zhou, Nannan; Xue, Guoqiang

    2018-05-01

    The grounded-wire transient electromagnetic method (TEM) has been widely used for near-surface metalliferous prospecting, oil and gas exploration, and hydrogeological surveying in the subsurface. However, it is commonly observed that such TEM signal is contaminated by the self-transient process occurred at the early stage of data acquisition. Correspondingly, there exists a minimum depth of investigation, above which the observed signal is not applicable for reliable data processing and interpretation. Therefore, for achieving a more comprehensive understanding of the TEM method, it is necessary to perform research on the self-transient process and moreover develop an approach for quantifying the minimum detection depth. In this paper, we first analyze the temporal procedure of the equivalent circuit of the TEM method and present a theoretical equation for estimating the self-induction voltage based on the inductor of the transmitting wire. Then, numerical modeling is applied for building the relationship between the minimum depth of investigation and various properties, including resistivity of the earth, offset, and source length. It is guide for the design of survey parameters when the grounded-wire TEM is applied to the shallow detection. Finally, it is verified through applications to a coal field in China.

  12. Product sampling during transient continuous countercurrent hydrolysis of canola oil and development of a kinetic model

    KAUST Repository

    Wang, Weicheng

    2013-11-01

    A chemical kinetic model has been developed for the transient stage of the continuous countercurrent hydrolysis of triglycerides to free fatty acids and glycerol. Departure functions and group contribution methods were applied to determine the equilibrium constants of the four reversible reactions in the kinetic model. Continuous countercurrent hydrolysis of canola oil in subcritical water was conducted experimentally in a lab-scale reactor over a range of temperatures and the concentrations of all neutral components were quantified. Several of the rate constants in the model were obtained by modeling this experimental data, with the remaining determined from calculated equilibrium constants. Some reactions not included in the present, or previous, hydrolysis modeling efforts were identified from glycerolysis kinetic studies and may explain the slight discrepancy between model and experiment. The rate constants determined in this paper indicate that diglycerides in the feedstock accelerate the transition from "emulsive hydrolysis" to "rapid hydrolysis". © 2013 Elsevier Ltd.

  13. Thermodynamic diagnosis of diesel and biodiesel combustion processes during load-increase transient sequences

    International Nuclear Information System (INIS)

    Armas, Octavio; Ballesteros, Rosario; Cardenas, María Dolores

    2012-01-01

    Highlights: ► Thermodynamic diagnosis was applied to diesel combustion process during transient operation. ► Comparative analysis of thermodynamic results with different biodiesel fuels has been carried out. ► Biodiesel fuels studied have a slight effect on timing of the combustion process. ► Methodology used can be applied to improve engine control when using different alternative fuels. -- Abstract: The study of the diesel combustion process is a current topic by the need of thermal efficiency improving and the reduction of pollutant emissions. This circumstance has forced researchers and manufacturers to optimize this process not only in steady state operating conditions but also during transient operation. A zero dimensional thermodynamic diagnostic model, with three species (air, fuel evaporated and burned products), has been used to characterize the combustion process during load increase transient sequences at two different engine speed. In both sequences, three variables were studied: the valve position of the exhaust gas recirculation (EGR), the elapsed time of the transition process and the type of fuel. Three biodiesel fuels were tested pure: rapeseed, soybean and sunflower which were compared to a commercial diesel fuel used as reference. Results are presented comparing the in-cylinder average maximum pressure and temperature, and the phasing of the combustion process based on the calculation of heat release. This study has allowed the detection of the effect of the tested engine parameters and the biodiesel fuels used on the in-cylinder thermodynamic conditions during the load transient sequences studied.

  14. Transient thermal model of passenger car's cabin and implementation to saturation cycle with alternative working fluids

    International Nuclear Information System (INIS)

    Lee, Hoseong; Hwang, Yunho; Song, Ilguk; Jang, Kilsang

    2015-01-01

    A transient thermal model of a passenger car's cabin is developed to investigate the dynamic behavior of cabin thermal conditions. The model is developed based on a lumped-parameter model and solved using integral methods. Solar radiation, engine heat through the firewall, and engine heat to the air ducts are all considered. Using the thermal model, transient temperature profiles of the interior mass and cabin air are obtained. This model is used to investigate the transient behavior of the cabin under various operating conditions: the recirculation mode in the idling state, the fresh air mode in the idling state, the recirculation mode in the driving state, and fresh air mode in the driving state. The developed model is validated by comparing with experimental data and is within 5% of deviation. The validated model is then applied for evaluating the mobile air conditioning system's design. The study found that a saturation cycle concept (four-stage cycle with two-phase refrigerant injection) could improve the system efficiency by 23.9% and reduce the power consumption by 19.3%. Lastly, several alternative refrigerants are applied and their performance is discussed. When the saturation cycle concept is applied, R1234yf MAC (mobile air conditioning) shows the largest COP (coefficient of performance) improvement and power consumption reduction. - Highlights: • The transient thermal model of the passenger car cabin is developed. • The developed model is validated with experimental data and showed 5% deviation. • Saturation cycle concept is applied to the developed cabin model. • There is 24% COP improvement by applying the saturation cycle concept. • R1234yf showed the highest potential when it is applied to the saturation cycle.

  15. Effect of additional holes on transient thermal fatigue life of gas turbine casing

    Directory of Open Access Journals (Sweden)

    H. Bazvandi

    2017-10-01

    Full Text Available Gas turbines casings are susceptible to cracking at the edge of eccentric pin hole, which is the most likely position for crack initiation and propagation. This paper describes the improvement of transient thermal fatigue crack propagation life of gas turbines casings through the application of additional holes. The crack position and direction was determined using non-destructive tests. A series of finite element patterns were developed and tested in ASTM-A395 elastic perfectly-plastic ductile cast iron. The effect of arrangement of additional holes on transient thermal fatigue behavior of gas turbines casings containing hole edge cracks was investigated. ABAQUS finite element package and Zencrack fracture mechanics code were used for modeling. The effect of the reduction of transient thermal stress distribution around the eccentric pin hole on the transient thermal fatigue crack propagation life of the gas turbines casings was discussed. The result shows that transient thermal fatigue crack propagation life could be extended by applying additional holes of larger diameter and decreased by increasing the vertical distance, angle, and distance between the eccentric pin hole and the additional holes. The results from the numerical predictions were compared with experimental data.

  16. Lithium Battery Transient Response as a Diagnostic Tool

    Science.gov (United States)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  17. Transient analysis of the new Cold Source at the FRM-II

    International Nuclear Information System (INIS)

    Gutsmiedl, E.; Posselt, H.; Scheuer, A.

    2003-01-01

    The new Cold Source (CNS) at the FRM-II research reactor is completely installed. This paper reports on the results of the transient analysis in the design status for this facility for producing cold neutrons for neutron experiments, the implementation of the results in the design of the mechanical components, the measurements at the cold tests and the comparison with the data of the transient analysis. The important load cases are fixed in the system description and the design data sheet of the CNS. A transient analysis was done with the computer program ESATAN, the nodal configuration was identical with the planned system of the CNS and the boundary conditions were chosen so, that conservative results can be expected. The following transients of the load cases in the piping system behind the inpile part 1) normal storage of D 2 at the hydride storage vessel 2) breakdown of cooling system of the CNS and transfer of D 2 to the buffer tank 3) rapid charge of D 2 to the buffer tank with break of the insulation vacuum and flooding of Neon 4) reloading of the D 2 from the buffer tank to the D 2 hydride storage vessel were calculated. Additionally the temperature distribution for these transients in the connecting flanges of the systems to the inpile part were analysed. The temperature distributions in the flange region were take into account for the strength calculation of the flange construction. The chosen construction shows allowable values and a leak tight flange connection for the load cases. The piping system was designed to the lowest expected temperatures. The load cases in the moderator tank were take into account in the stress analysis and the fatigue analysis of the vacuum vessel and the moderator vessel. The results shows allowable stresses. The results shows that a transient analysis is necessary and helpful for good design of the CNS. (author)

  18. Homogeneous (Cu, Ni)6Sn5 intermetallic compound joints rapidly formed in asymmetrical Ni/Sn/Cu system using ultrasound-induced transient liquid phase soldering process.

    Science.gov (United States)

    Li, Z L; Dong, H J; Song, X G; Zhao, H Y; Tian, H; Liu, J H; Feng, J C; Yan, J C

    2018-04-01

    Homogeneous (Cu, Ni) 6 Sn 5 intermetallic compound (IMC) joints were rapidly formed in asymmetrical Ni/Sn/Cu system by an ultrasound-induced transient liquid phase (TLP) soldering process. In the traditional TLP soldering process, the intermetallic joints formed in Ni/Sn/Cu system consisted of major (Cu, Ni) 6 Sn 5 and minor Cu 3 Sn IMCs, and the grain morphology of (Cu, Ni) 6 Sn 5 IMCs subsequently exhibited fine rounded, needlelike and coarse rounded shapes from the Ni side to the Cu side, which was highly in accordance with the Ni concentration gradient across the joints. However, in the ultrasound-induced TLP soldering process, the intermetallic joints formed in Ni/Sn/Cu system only consisted of the (Cu, Ni) 6 Sn 5 IMCs which exhibited an uniform grain morphology of rounded shape with a remarkably narrowed Ni concentration gradient. The ultrasound-induced homogeneous intermetallic joints exhibited higher shear strength (61.6 MPa) than the traditional heterogeneous intermetallic joints (49.8 MPa). Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zevenhoven, Koos C. J.; Ilmoniemi, Risto J.; Dong, Hui; Clarke, John

    2015-01-01

    Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents

  20. A fast transient response low dropout regulator with current control methodology

    Energy Technology Data Exchange (ETDEWEB)

    Ma Zhuo; Guo Yang; Duan Zhikui; Xie Lunguo; Chen Jihua; Yu Jinshan, E-mail: guoyang@nudt.edu.cn [School of Computer, National University of Defense Technology, Changsha 410073 (China)

    2011-08-15

    A transient performance optimized CCL-LDO regulator is proposed. In the CCL-LDO, the control method of the charge pump phase-locked loop is adopted. A current control loop has the feedback signal and reference current to be compared, and then a loop filter generates the gate voltage of the power MOSFET by integrating the error current. The CCL-LDO has the optimized damping coefficient and natural resonant frequency, while its output voltage can be sub-1-V and is not restricted by the reference voltage. With a 1 {mu}F decoupling capacitor, the experimental results based on a 0.13 {mu}m CMOS process show that the output voltage is 1.0 V; when the workload changes from 100 {mu}A to 100 mA transiently, the stable dropout is 4.25 mV, the settling time is 8.2 {mu}s and the undershoot is 5.11 mV; when the workload changes from 100 mA to 100 {mu}A transiently, the stable dropout is 4.25 mV, the settling time is 23.3 {mu}s and the overshoot is 6.21 mV. The PSRR value is more than -95 dB. Most of the attributes of the CCL-LDO are improved rapidly with a FOM value of 0.0097.

  1. A fast transient response low dropout regulator with current control methodology

    International Nuclear Information System (INIS)

    Ma Zhuo; Guo Yang; Duan Zhikui; Xie Lunguo; Chen Jihua; Yu Jinshan

    2011-01-01

    A transient performance optimized CCL-LDO regulator is proposed. In the CCL-LDO, the control method of the charge pump phase-locked loop is adopted. A current control loop has the feedback signal and reference current to be compared, and then a loop filter generates the gate voltage of the power MOSFET by integrating the error current. The CCL-LDO has the optimized damping coefficient and natural resonant frequency, while its output voltage can be sub-1-V and is not restricted by the reference voltage. With a 1 μF decoupling capacitor, the experimental results based on a 0.13 μm CMOS process show that the output voltage is 1.0 V; when the workload changes from 100 μA to 100 mA transiently, the stable dropout is 4.25 mV, the settling time is 8.2 μs and the undershoot is 5.11 mV; when the workload changes from 100 mA to 100 μA transiently, the stable dropout is 4.25 mV, the settling time is 23.3 μs and the overshoot is 6.21 mV. The PSRR value is more than -95 dB. Most of the attributes of the CCL-LDO are improved rapidly with a FOM value of 0.0097.

  2. Analysis of Transient Phenomena Due to a Direct Lightning Strike on a Wind Energy System

    Directory of Open Access Journals (Sweden)

    João P. S. Catalão

    2012-07-01

    Full Text Available This paper is concerned with the protection of wind energy systems against the direct effects of lightning. As wind power generation undergoes rapid growth, lightning damages involving wind turbines have come to be regarded as a serious problem. Nevertheless, very few studies exist yet in Portugal regarding lightning protection of wind energy systems using numerical codes. A new case study is presented in this paper, based on a wind turbine with an interconnecting transformer, for the analysis of transient phenomena due to a direct lightning strike to the blade. Comprehensive simulation results are provided by using models of the Restructured Version of the Electro-Magnetic Transients Program (EMTP, and conclusions are duly drawn.

  3. Peptidomics Analysis of Transient Regeneration in the Neonatal Mouse Heart.

    Science.gov (United States)

    Fan, Yi; Zhang, Qijun; Li, Hua; Cheng, Zijie; Li, Xing; Chen, Yumei; Shen, Yahui; Wang, Liansheng; Song, Guixian; Qian, Lingmei

    2017-09-01

    Neonatal mouse hearts have completely regenerative capability after birth, but the ability to regenerate rapidly lost after 7 days, the mechanism has not been clarified. Previous studies have shown that mRNA profile of adult mouse changed greatly compared to neonatal mouse. So far, there is no research of peptidomics related to heart regeneration. In order to explore the changes of proteins, enzymes, and peptides related to the transient regeneration, we used comparative petidomics technique to compare the endogenous peptides in the mouse heart of postnatal 1 and 7 days. In final, we identified 236 differentially expressed peptides, 169 of which were upregulated and 67 were downregulated in the postnatal 1 day heart, and also predicted 36 functional peptides associated with transient regeneration. The predicted 36 candidate peptides are located in the important domains of precursor proteins and/or contain the post-transcriptional modification (PTM) sites, which are involved in the biological processes of cardiac development, cardiac muscle disease, cell proliferation, necrosis, and apoptosis. In conclusion, for the first time, we compared the peptidomics profiles of neonatal heart between postnatal 1 day and postnatal 7 day. This study provides a new direction and an important basis for the mechanism research of transient regeneration in neonatal heart. J. Cell. Biochem. 118: 2828-2840, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. The simulation of transients in thermal plant. Part II: Applications

    International Nuclear Information System (INIS)

    Morini, G.L.; Piva, S.

    2008-01-01

    This paper deals with the simulation of the transients of thermal plant with control systems. In the companion paper forming part I of this article [G.L. Morini, S. Piva, The simulation of transients in thermal plant. Part I: Mathematical model, Applied Thermal Engineering 27 (2007) 2138-2144] it has been described how a 'thermal-library' of customised blocks can be built and used, in an intuitive way, to study the transients of any kind of thermal plant. Each component of plant such as valves, boilers, and pumps, is represented by a single block. In this paper, the 'thermal-library' approach is demonstrated by the analysis of the dynamic behaviour of a central heating plant of a typical apartment house during a sinusoidal variation of the external temperature. A comparison of the behaviour of such a plant with three way valve working either in flow rate or in temperature control, is presented and discussed. Finally, the results show the delaying effect of the thermal capacity of the building on the performance of the control system

  5. Analysis of loss of normal feedwater transient using RELAP5/MOD1/NSC; KNU1 plant simulation

    International Nuclear Information System (INIS)

    Kim, Hho Jung; Chung, Bub Dong; Lee, Young Jin; Kim, Jin Soo

    1986-01-01

    Simulation of the system thermal-hydraulic parameters was carried out following the KNU1(Korea Nuclear Unit-1) loss of normal feedwater transient sequence occurred on november 14, 1984. Results were compared with the plant transient data, and good agreements were obtained. Some deviations were found in the parameters such as the steam flowrate and the RCS(Reactor Coolant System) average temperature, around the time of reactor trip. It can be expected since the thermal-hydraulic parameters encounter rapid transitions due to the large reduction of the reactor thermal power in a short period of time and, thereby, the plant data involve transient uncertainties. The analysis was performed using the RELAP5/MOD1/NSC developed through some modifications of the interphase drag and the wall heat transfer modeling routines of the RELAP5/MOD1/CY018. (Author)

  6. A parallel finite-volume finite-element method for transient compressible turbulent flows with heat transfer

    International Nuclear Information System (INIS)

    Masoud Ziaei-Rad

    2010-01-01

    In this paper, a two-dimensional numerical scheme is presented for the simulation of turbulent, viscous, transient compressible flows in the simultaneously developing hydraulic and thermal boundary layer region. The numerical procedure is a finite-volume-based finite-element method applied to unstructured grids. This combination together with a new method applied for the boundary conditions allows for accurate computation of the variables in the entrance region and for a wide range of flow fields from subsonic to transonic. The Roe-Riemann solver is used for the convective terms, whereas the standard Galerkin technique is applied for the viscous terms. A modified κ-ε model with a two-layer equation for the near-wall region combined with a compressibility correction is used to predict the turbulent viscosity. Parallel processing is also employed to divide the computational domain among the different processors to reduce the computational time. The method is applied to some test cases in order to verify the numerical accuracy. The results show significant differences between incompressible and compressible flows in the friction coefficient, Nusselt number, shear stress and the ratio of the compressible turbulent viscosity to the molecular viscosity along the developing region. A transient flow generated after an accidental rupture in a pipeline was also studied as a test case. The results show that the present numerical scheme is stable, accurate and efficient enough to solve the problem of transient wall-bounded flow.

  7. Searching for MHz Transients with the VLA Low-band Ionosphere and Transient Experiment (VLITE)

    Science.gov (United States)

    Polisensky, Emil; Peters, Wendy; Giacintucci, Simona; Clarke, Tracy; Kassim, Namir E.; hyman, Scott D.; van der Horst, Alexander; Linford, Justin; Waldron, Zach; Frail, Dale

    2018-01-01

    NRL and NRAO have expanded the low frequency capabilities of the VLA through the VLA Low-band Ionosphere and Transient Experiment (VLITE, http://vlite.nrao.edu/ ), effectively making the instrument two telescopes in one. VLITE is a commensal observing system that harvests data from the prime focus in parallel with normal Cassegrain focus observing on a subset of VLA antennas. VLITE provides over 6000 observing hours per year in a > 5 square degree field-of-view using 64 MHz bandwidth centered on 352 MHz. By operating in parallel, VLITE offers invaluable low frequency data to targeted observations of transient sources detected at higher frequencies. With arcsec resolution and mJy sensitivity, VLITE additionally offers great potential for blind searches of rarer radio-selected transients. We use catalog matching software on the imaging products from the daily astrophysics pipeline and the LOFAR Transients Pipeline (TraP) on repeated observations of the same fields to search for coherent and incoherent astronomical transients on timescales of a few seconds to years. We present the current status of the VLITE transient science program from its initial deployment on 10 antennas in November 2014 through its expansion to 16 antennas in the summer of 2017. Transient limits from VLITE’s first year of operation (Polisensky et al. 2016) are updated per the most recent analysis.

  8. Performance of neutron kinetics models for ADS transient analyses

    International Nuclear Information System (INIS)

    Rineiski, A.; Maschek, W.; Rimpault, G.

    2002-01-01

    can also apply this approach for estimating errors of point-kinetics simulations or for ameliorating the employed point-kinetics models. Though the performance of the point-kinetics model can be insufficient in the subcritical case, the quasi-static approach is still valid if the shape steps are chosen properly. It is worthwhile to mention that in combination with properly computed correction factor tables, one can use the reactivity and power distributions obtained for 'critical' reactor models; this approach can simplify ADS-related application of conventional accident analyses codes (developed in the past for transient analyses of critical reactors). However, for analyzing severe transients in ADSs, which involve gross core material configuration changes, one can hardly avoid using of space-time kinetics methods, this holds similarly for critical reactor systems. (authors)

  9. On-line transient stability assessment of large-scale power systems by using ball vector machines

    International Nuclear Information System (INIS)

    Mohammadi, M.; Gharehpetian, G.B.

    2010-01-01

    In this paper ball vector machine (BVM) has been used for on-line transient stability assessment of large-scale power systems. To classify the system transient security status, a BVM has been trained for all contingencies. The proposed BVM based security assessment algorithm has very small training time and space in comparison with artificial neural networks (ANN), support vector machines (SVM) and other machine learning based algorithms. In addition, the proposed algorithm has less support vectors (SV) and therefore is faster than existing algorithms for on-line applications. One of the main points, to apply a machine learning method is feature selection. In this paper, a new Decision Tree (DT) based feature selection technique has been presented. The proposed BVM based algorithm has been applied to New England 39-bus power system. The simulation results show the effectiveness and the stability of the proposed method for on-line transient stability assessment procedure of large-scale power system. The proposed feature selection algorithm has been compared with different feature selection algorithms. The simulation results demonstrate the effectiveness of the proposed feature algorithm.

  10. Charged particle transport in gaseous nitrogen at intermediate E/N using the voltage transient method

    International Nuclear Information System (INIS)

    Purdie, P.H.; Fletcher, J.

    1992-01-01

    A pulsed swarm of charged particles crossing an inter-electrode gap under the influence of an applied electric field E will produce a pulsed current in the external circuit which, when integrated over time, will result in a transient voltage pulse, the shape and magnitude of which is characteristic of the number of type of charged particles. This voltage transient technique has been used to investigate a gas discharge in nitrogen gas at values of E/N (the ratio of applied electric field to gas number density), such that ionization is non-negligible. The voltage transients have been subjected to a theoretical analysis, which has previously been reported, which includes not only cathode and anode image terms but also both electron and ion diffusion terms. Electron transport parameters are reported for E/N ≤ 350 Td (1 Td = 10 -17 V cm 2 ). Data are also obtained for the drift velocities and diffusion coefficients of the ions operative within the nitrogen discharge. An estimate is obtained for the collisional decay rate of N 2 + . 21 refs., 7 figs

  11. Response of the human tympanic membrane to transient acoustic and mechanical stimuli: Preliminary results

    Science.gov (United States)

    Razavi, Payam; Ravicz, Michael E.; Dobrev, Ivo; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J.

    2016-01-01

    The response of the tympanic membrane (TM) to transient environmental sounds and the contributions of different parts of the TM to middle-ear sound transmission were investigated by measuring the TM response to global transients (acoustic clicks) and to local transients (mechanical impulses) applied to the umbo and various locations on the TM. A lightly-fixed human temporal bone was prepared by removing the ear canal, inner ear, and stapes, leaving the incus, malleus, and TM intact. Motion of nearly the entire TM was measured by a digital holography system with a high speed camera at a rate of 42 000 frames per second, giving a temporal resolution of <24 μs for the duration of the TM response. The entire TM responded nearly instantaneously to acoustic transient stimuli, though the peak displacement and decay time constant varied with location. With local mechanical transients, the TM responded first locally at the site of stimulation, and the response spread approximately symmetrically and circumferentially around the umbo and manubrium. Acoustic and mechanical transients provide distinct and complementary stimuli for the study of TM response. Spatial variations in decay and rate of spread of response imply local variations in TM stiffness, mass, and damping. PMID:26880098

  12. Transient Response of Thin Wire above a Layered Half-Space Using TDIE/FDTD Hybrid Method

    Directory of Open Access Journals (Sweden)

    Bing Wei

    2012-01-01

    Full Text Available The TDIE/FDTD hybrid method is applied to calculate the transient responses of thin wire above a lossy layered half-space. The time-domain reflection of the layered half space is computed by one-dimensional modified FDTD method. Then, transient response of thin wire induced by two excitation sources (the incident wave and reflected wave is calculated by TDIE method. Finally numerical results are given to illustrate the feasibility and high efficiency of the presented scheme.

  13. Modelling and transient simulation of water flow in pipelines using WANDA Transient software

    Directory of Open Access Journals (Sweden)

    P.U. Akpan

    2017-09-01

    Full Text Available Pressure transients in conduits such as pipelines are unsteady flow conditions caused by a sudden change in the flow velocity. These conditions might cause damage to the pipelines and its fittings if the extreme pressure (high or low is experienced within the pipeline. In order to avoid this occurrence, engineers usually carry out pressure transient analysis in the hydraulic design phase of pipeline network systems. Modelling and simulation of transients in pipelines is an acceptable and cost effective method of assessing this problem and finding technical solutions. This research predicts the pressure surge for different flow conditions in two different pipeline systems using WANDA Transient simulation software. Computer models were set-up in WANDA Transient for two different systems namely; the Graze experiment (miniature system and a simple main water riser system based on some initial laboratory data and system parameters. The initial laboratory data and system parameters were used for all the simulations. Results obtained from the computer model simulations compared favourably with the experimental results at Polytropic index of 1.2.

  14. Applying Bayesian belief networks in rapid response situations

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, William L [Los Alamos National Laboratory; Deborah, Leishman, A. [Los Alamos National Laboratory; Van Eeckhout, Edward [Los Alamos National Laboratory

    2008-01-01

    The authors have developed an enhanced Bayesian analysis tool called the Integrated Knowledge Engine (IKE) for monitoring and surveillance. The enhancements are suited for Rapid Response Situations where decisions must be made based on uncertain and incomplete evidence from many diverse and heterogeneous sources. The enhancements extend the probabilistic results of the traditional Bayesian analysis by (1) better quantifying uncertainty arising from model parameter uncertainty and uncertain evidence, (2) optimizing the collection of evidence to reach conclusions more quickly, and (3) allowing the analyst to determine the influence of the remaining evidence that cannot be obtained in the time allowed. These extended features give the analyst and decision maker a better comprehension of the adequacy of the acquired evidence and hence the quality of the hurried decisions. They also describe two example systems where the above features are highlighted.

  15. RFI flagging implications for short-duration transients

    Science.gov (United States)

    Cendes, Y.; Prasad, P.; Rowlinson, A.; Wijers, R. A. M. J.; Swinbank, J. D.; Law, C. J.; van der Horst, A. J.; Carbone, D.; Broderick, J. W.; Staley, T. D.; Stewart, A. J.; Huizinga, F.; Molenaar, G.; Alexov, A.; Bell, M. E.; Coenen, T.; Corbel, S.; Eislöffel, J.; Fender, R.; Grießmeier, J.-M.; Jonker, P.; Kramer, M.; Kuniyoshi, M.; Pietka, M.; Stappers, B.; Wise, M.; Zarka, P.

    2018-04-01

    With their wide fields of view and often relatively long coverage of any position in the sky in imaging survey mode, modern radio telescopes provide a data stream that is naturally suited to searching for rare transients. However, Radio Frequency Interference (RFI) can show up in the data stream in similar ways to such transients, and thus the normal pre-treatment of filtering RFI (flagging) may also remove astrophysical transients from the data stream before imaging. In this paper we investigate how standard flagging affects the detectability of such transients by examining the case of transient detection in an observing mode used for Low Frequency Array (LOFAR; van Haarlem et al., 2013) surveys. We quantify the fluence range of transients that would be detected, and the reduction of their SNR due to partial flagging. We find that transients with a duration close to the integration sampling time, as well as bright transients with durations on the order of tens of seconds, are completely flagged. For longer transients on the order of several tens of seconds to minutes, the flagging effects are not as severe, although part of the signal is lost. For these transients, we present a modified flagging strategy which mitigates the effect of flagging on transient signals. We also present a script which uses the differences between the two strategies, and known differences between transient RFI and astrophysical transients, to notify the observer when a potential transient is in the data stream.

  16. Transient analysis of intermittent multijet sprays

    Energy Technology Data Exchange (ETDEWEB)

    Panao, Miguel R.O.; Moreira, Antonio Luis N. [Universidade Tecnica de Lisboa, IN, Center for Innovation, Technology and Policy Research, Instituto Superior Tecnico, Lisboa (Portugal); Durao, Diamantino G. [Universidade Lusiada, Lisboa (Portugal)

    2012-07-15

    This paper analyzes the transient characteristics of intermittent sprays produced by the single-point impact of multiple cylindrical jets. The aim is to perform a transient analysis of the intermittent atomization process to study the effect of varying the number of impinging jets in the hydrodynamic mechanisms of droplet formation. The results evidence that hydrodynamic mechanisms underlying the physics of ligament fragmentation in 2-impinging jets sprays also apply to sprays produced with more than 2 jets during the main period of injection. Ligaments detaching from the liquid sheet, as well as from its bounding rim, have been identified and associated with distinct droplet clusters, which become more evident as the number of impinging jets increases. Droplets produced by detached ligaments constitute the main spray, and their axial velocity becomes more uniformly distributed with 4-impinging jets because of a delayed ligament fragmentation. Multijet spray dispersion patterns are geometric depending on the number of impinging jets. Finally, an analysis on the Weber number of droplets suggests that multijet sprays are more likely to deposit on interposed surfaces, thus becoming a promising and competitive atomization solution for improving spray cooling. (orig.)

  17. Transient flow assurance for determination of operational control of heavy oil pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Cabrejo, Victor [TransCanada Pipelines Ltd, (Canada); Mohitpour, Mo [Tempsys Pipeline Solutions Inc., (Canada)

    2010-07-01

    Pipeline transmission systems have been designed traditionally using steady state simulations. Steady state simulation provided sufficient values for simple systems, but is limited in dealing with surges in flow rates, loss of facilities and facility operation. A dynamic approach is required to test the capacity of a system for various fluids. This paper investigated the use of transient analysis of liquid pipelines in order to improve the design of these pipelines and to achieve operational benefits. The transient method and its use are discussed. Dynamic analysis was applied to the Keystone Pipeline Project. The purpose of the study was first to determine the system capacity and data for transportation of Heavy DilBit, and then to implement batch transportation of a volume of synthetic crude oil. It was found that the use of transient modeling in design and operational assessment of a liquid pipeline ensures system capability, control, safety and integrity.

  18. Transient performance estimation of charge plasma based negative capacitance junctionless tunnel FET

    International Nuclear Information System (INIS)

    Singh, Sangeeta; Kondekar, P. N.; Pal, Pawan

    2016-01-01

    We investigate the transient behavior of an n-type double gate negative capacitance junctionless tunnel field effect transistor (NC-JLTFET). The structure is realized by using the work-function engineering of metal electrodes over a heavily doped n + silicon channel and a ferroelectric gate stack to get negative capacitance behavior. The positive feedback in the electric dipoles of ferroelectric materials results in applied gate bias boosting. Various device transient parameters viz. transconductance, output resistance, output conductance, intrinsic gain, intrinsic gate delay, transconductance generation factor and unity gain frequency are analyzed using ac analysis of the device. To study the impact of the work-function variation of control and source gate on device performance, sensitivity analysis of the device has been carried out by varying these parameters. Simulation study reveals that it preserves inherent advantages of charge-plasma junctionless structure and exhibits improved transient behavior as well. (paper)

  19. LLL transient-electromagnetics-measurement facility

    International Nuclear Information System (INIS)

    Deadrick, F.J.; Miller, E.K.; Hudson, H.G.

    1975-01-01

    The operation and hardware of the Lawrence Livermore Laboratory's transient-electromagnetics (EM)-measurement facility are described. The transient-EM range is useful for determining the time-domain transient responses of structures to incident EM pulses. To illustrate the accuracy and utility of the EM-measurement facility, actual experimental measurements are compared to numerically computed values

  20. Study of electron mobility in small molecular SAlq by transient electroluminescence method

    Science.gov (United States)

    Kumar, Pankaj; Jain, S. C.; Kumar, Vikram; Chand, Suresh; Kamalasanan, M. N.; Tandon, R. P.

    2007-12-01

    The study of electron mobility of bis(2-methyl 8-hydroxyquinoline) (triphenyl siloxy) aluminium (SAlq) by transient electroluminescence (EL) is presented. An EL device is fabricated in bilayer, ITO/N,N'-diphenyl-N, N'-bis(3-methylphenyl)-(1,1'-biphenyl)-4,4'-diamine (TPD)/SAlq/LiF/Al configuration. The temporal evaluation of the EL with respect to the step voltage pulse is characterized by a delay time followed by a fast initial rise, which is followed by a slower rise. The delay time between the applied electrical pulse and the onset of EL is correlated with the carrier mobility (electron in our case). Transient EL studies for SAlq have been carried out at different temperatures and different applied electric fields. The electron mobility in SAlq is found to be field and temperature dependent and calculated to be 6.9 × 10-7 cm2 V-1 s-1 at 2.5 × 106 V cm-1 and 308 K. The EL decays immediately as the voltage is turned off and does not depend on the amplitude of the applied voltage pulse or dc offset.

  1. Transient and fuel performance analysis with VTT's coupled code system

    International Nuclear Information System (INIS)

    Daavittila, A.; Hamalainen, A.; Raty, H.

    2005-01-01

    VTT (technical research center of Finland) maintains and further develops a comprehensive safety analysis code system ranging from the basic neutronic libraries to 3-dimensional transient analysis and fuel behaviour analysis codes. The code system is based on various types of couplings between the relevant physical phenomena. The main tools for analyses of reactor transients are presently the 3-dimensional reactor dynamics code HEXTRAN for cores with a hexagonal fuel assembly geometry and TRAB-3D for cores with a quadratic fuel assembly geometry. HEXTRAN has been applied to safety analyses of VVER type reactors since early 1990's. TRAB-3D is the latest addition to the code system, and has been applied to BWR and PWR analyses in recent years. In this paper it is shown that TRAB-3D has calculated accurately the power distribution during the Olkiluoto-1 load rejection test. The results from the 3-dimensional analysis can be used as boundary conditions for more detailed fuel rod analysis. For this purpose a general flow model GENFLO, developed at VTT, has been coupled with USNRC's FRAPTRAN fuel accident behaviour model. The example case for FRAPTRAN-GENFLO is for an ATWS at a BWR plant. The basis for the analysis is an oscillation incident in the Olkiluoto-1 BWR during reactor startup on February 22, 1987. It is shown that the new coupled code FRAPTRAN/GENFLO is quite a promising tool that can handle flow situations and give a detailed analysis of reactor transients

  2. Fatigue Analysis of Tubesheet/Shell Juncture Applying the Mitigation Factor for Over-conservatism

    International Nuclear Information System (INIS)

    Kang, Deog Ji; Kim, Kyu Hyoung; Lee, Jae Gon

    2009-01-01

    If the environmental fatigue requirements are applied to the primary components of a nuclear power plant, to which the present ASME Code fatigue curves are applied, some locations with high level CUF (Cumulative Usage Factor) are anticipated not to meet the code criteria. The application of environmental fatigue damage is still particularly controversial for plants with 60-year design lives. Therefore, it is need to develop a detailed fatigue analysis procedure to identify the conservatisms in the procedure and to lower the cumulative usage factor. Several factors are being considered to mitigate the conservatism such as three-dimensional finite element modeling. In the present analysis, actual pressure transient data instead of conservative maximum and minimum pressure data was applied as one of mitigation factors. Unlike in the general method, individual transient events were considered instead of the grouped transient events. The tubesheet/shell juncture in the steam generator assembly is the one of the weak locations and was, therefore, selected as a target to evaluate the mitigation factor in the present analysis

  3. Transient coupled calculations of the Molten Salt Fast Reactor using the Transient Fission Matrix approach

    Energy Technology Data Exchange (ETDEWEB)

    Laureau, A., E-mail: laureau.axel@gmail.com; Heuer, D.; Merle-Lucotte, E.; Rubiolo, P.R.; Allibert, M.; Aufiero, M.

    2017-05-15

    Highlights: • Neutronic ‘Transient Fission Matrix’ approach coupled to the CFD OpenFOAM code. • Fission Matrix interpolation model for fast spectrum homogeneous reactors. • Application for coupled calculations of the Molten Salt Fast Reactor. • Load following, over-cooling and reactivity insertion transient studies. • Validation of the reactor intrinsic stability for normal and accidental transients. - Abstract: In this paper we present transient studies of the Molten Salt Fast Reactor (MSFR). This generation IV reactor is characterized by a liquid fuel circulating in the core cavity, requiring specific simulation tools. An innovative neutronic approach called “Transient Fission Matrix” is used to perform spatial kinetic calculations with a reduced computational cost through a pre-calculation of the Monte Carlo spatial and temporal response of the system. Coupled to this neutronic approach, the Computational Fluid Dynamics code OpenFOAM is used to model the complex flow pattern in the core. An accurate interpolation model developed to take into account the thermal hydraulics feedback on the neutronics including reactivity and neutron flux variation is presented. Finally different transient studies of the reactor in normal and accidental operating conditions are detailed such as reactivity insertion and load following capacities. The results of these studies illustrate the excellent behavior of the MSFR during such transients.

  4. Transient coupled calculations of the Molten Salt Fast Reactor using the Transient Fission Matrix approach

    International Nuclear Information System (INIS)

    Laureau, A.; Heuer, D.; Merle-Lucotte, E.; Rubiolo, P.R.; Allibert, M.; Aufiero, M.

    2017-01-01

    Highlights: • Neutronic ‘Transient Fission Matrix’ approach coupled to the CFD OpenFOAM code. • Fission Matrix interpolation model for fast spectrum homogeneous reactors. • Application for coupled calculations of the Molten Salt Fast Reactor. • Load following, over-cooling and reactivity insertion transient studies. • Validation of the reactor intrinsic stability for normal and accidental transients. - Abstract: In this paper we present transient studies of the Molten Salt Fast Reactor (MSFR). This generation IV reactor is characterized by a liquid fuel circulating in the core cavity, requiring specific simulation tools. An innovative neutronic approach called “Transient Fission Matrix” is used to perform spatial kinetic calculations with a reduced computational cost through a pre-calculation of the Monte Carlo spatial and temporal response of the system. Coupled to this neutronic approach, the Computational Fluid Dynamics code OpenFOAM is used to model the complex flow pattern in the core. An accurate interpolation model developed to take into account the thermal hydraulics feedback on the neutronics including reactivity and neutron flux variation is presented. Finally different transient studies of the reactor in normal and accidental operating conditions are detailed such as reactivity insertion and load following capacities. The results of these studies illustrate the excellent behavior of the MSFR during such transients.

  5. Analytic models for fuel pin transient performance

    International Nuclear Information System (INIS)

    Bard, F.E.; Fox, G.L.; Washburn, D.F.; Hanson, J.E.

    1976-09-01

    HEDL's ability to analyze various mechanisms that operate within a fuel pin has progressed substantially through development of codes such as PECTCLAD, which solves cladding response, and DSTRESS, which solves fuel response. The PECTCLAD results show good correlation with a variety of mechanical tests on cladding material and also demonstrate the significance of cladding strength when applying the life fraction rule. The DSTRESS results have shown that fuel deforms sufficiently during overpower transient tests that available volumes are filled, whether in the form of a central cavity or start-up cracks

  6. TRAWA, a transient analysis code for water reactions

    International Nuclear Information System (INIS)

    Rajamaeki, M.

    1976-06-01

    TRAWA is a transient analysis code for water reactors. It solves the two-group neutron diffusion equations simultaneously with the heat conduction equations and the two-phase hydraulic equations for one or more channels. At most one-dimensional submodels are used. Neither thermal nor hydraulic mixing appear between channels. Doppler, coolant density, coolant temperature, and soluble poison density feedbacks due to the thermohydraulics of the channels are described by using polynomial expansions for the group constants. The hydraulic circuit outside the reactor core consists of by-pass channel and risers with two-phase flow and of pump lines with incompressible flow. Nontrivial implicit methods are employed in the discretization of the equations to allow for sparse spatial mesh and flexible choice of time steps. Various transients can be calculated by applying external disturbances. The code is extensively supplied by input and output capabilities. TRAWA is written in FORTRAN V for UNIVAC 1108 computer. (author)

  7. Fast Turn-off Mine Transient Electromagnetic Transmitter System

    Directory of Open Access Journals (Sweden)

    ZHENG Xiao-Liang

    2014-05-01

    Full Text Available For solving problems such as short turn-off time, high linear degree of falling edge, measurement of turn-off time and influence of primary signals for transient electromagnetic transmitter, and restrictions because of the environmental conditions of underground coal mine, this thesis aims at designing a new transient electromagnetic transmitter system suitable for coal mine. Supported by damping absorption circuit, such system applies small volume, sectional transmitting coil, with features of short turn-off time, high linear degree of current falling edge. It uses the transmitter monitoring circuit, which accurately measures turn-off time and simultaneously records the current value changes after turn-off, thus to eliminate the influence of primary field as well as to restore earlier secondary field signals for reference and finally to improve the ability to detect the shallow structure. It turns out that the new system has a shorter turn-off time, a higher linear degree of current falling and more accurate data record of turn-off current.

  8. Enhanced backpropagation training algorithm for transient event identification

    International Nuclear Information System (INIS)

    Vitela, J.; Reifman, J.

    1993-01-01

    We present an enhanced backpropagation (BP) algorithm for training feedforward neural networks that avoids the undesirable premature saturation of the network output nodes and accelerates the training process even in cases where premature saturation is not present. When the standard BP algorithm is applied to train patterns of nuclear power plant (NPP) transients, the network output nodes often become prematurely saturated causing the already slow rate of convergence of the algorithm to become even slower. When premature saturation occurs, the gradient of the prediction error becomes very small, although the prediction error itself is still large, yielding negligible weight updates and hence no significant decrease in the prediction error until the eventual recovery of the output nodes from saturation. By defining the onset of premature saturation and systematically modifying the gradient of the prediction error at saturation, we developed an enhanced BP algorithm that is compared with the standard BP algorithm in training a network to identify NPP transients

  9. CONNECTING FLARES AND TRANSIENT MASS-LOSS EVENTS IN MAGNETICALLY ACTIVE STARS

    Energy Technology Data Exchange (ETDEWEB)

    Osten, Rachel A. [Space Telescope Science Institute 3700 San Martin Drive, Baltimore, MD 21218 (United States); Wolk, Scott J., E-mail: osten@stsci.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge MA 02138 (United States)

    2015-08-10

    We explore the ramification of associating the energetics of extreme magnetic reconnection events with transient mass-loss in a stellar analogy with solar eruptive events. We establish energy partitions relative to the total bolometric radiated flare energy for different observed components of stellar flares and show that there is rough agreement for these values with solar flares. We apply an equipartition between the bolometric radiated flare energy and kinetic energy in an accompanying mass ejection, seen in solar eruptive events and expected from reconnection. This allows an integrated flare rate in a particular waveband to be used to estimate the amount of associated transient mass-loss. This approach is supported by a good correspondence between observational flare signatures on high flaring rate stars and the Sun, which suggests a common physical origin. If the frequent and extreme flares that young solar-like stars and low-mass stars experience are accompanied by transient mass-loss in the form of coronal mass ejections, then the cumulative effect of this mass-loss could be large. We find that for young solar-like stars and active M dwarfs, the total mass lost due to transient magnetic eruptions could have significant impacts on disk evolution, and thus planet formation, and also exoplanet habitability.

  10. Manifestation of transient effects in fission induced by relativistic heavy-ion collisions

    Energy Technology Data Exchange (ETDEWEB)

    Jurado, B.; Schmitt, C.; Schmidt, K.H.; Benlliure, J. [Universidad de Santiago de Compostela (Spain); Junghans, A.R. [Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany)

    2004-03-01

    We examine the manifestation of transient effects in fission by analysing experimental data where fission is induced by peripheral heavy-ion collisions at relativistic energies. Available total nuclear fission cross sections of {sup 238}U at1.A GeV on gold and uranium targets are compared with a nuclear-reaction code, where transient effects in fission are modelled using different approximations to the numerical time-dependent fission-decay width: a new analytical description based on the solution of the Fokker-Planck equation and two widely used but less realistic descriptions, a step function and an exponential-like function. The experimental data are only reproduced when transient effects are considered. The deduced value of the dissipation strength {beta} depends strongly on the approximation applied for the time-dependent fission-decay width and is estimated to be of the order of 2 x 10{sup 21} s{sup -1}. A careful analysis sheds severe doubts on the use of the exponential-like in-growth function largely used in the past. Finally, we discuss which should be the characteristics of experimental observables to be most sensitive to transient effects in fission. (orig.)

  11. Whole-core thermal-hydraulic transient code development and verification for LMFBR analysis

    International Nuclear Information System (INIS)

    Spencer, D.R.

    1979-04-01

    Predicted performance during both steady state and transient reactor operation determines the steady state operating limits on LMFBRs. Unnecessary conservatism in performance predictions will not contribute to safety, but will restrict the reactor to more conservative, less economical steady state operation. The most general method for reducing analytical conservatism in LMFBR's without compromising safety is to develop, validate and apply more sophisticated computer models to the limiting performance analyses. The purpose of the on-going Natural Circulation Verification Program (NCVP) is to develop and validate computer codes to analyze natural circulation transients in LMFBRs, and thus, replace unnecessary analytical conservatism with demonstrated calculational capability

  12. Multiple Order Diffractions by laser-Injured Transient Grating in Nematic MBBA Film

    International Nuclear Information System (INIS)

    Kim, Seong Kyu; Kim, Hack Jin

    1999-01-01

    The laser-induced transient grating method is applied to study the dynamics of the nematic MBBA film. The nanosecond laser pulses of 355 nm are used to make the transient grating and the cw He-Ne laser of 633 nm is used to probe the dynamics. Strong multiple order diffractions are observed at high nematic temperatures. The reordering process induced by the phototransformed state, which is the locally melted state from the nematic sample, is attributed to the main origin of the multiple order diffractions from the nematic MBBA. The characteristics of the multiple order gratings are discussed with the grating profiles simulated from the multiple diffraction signals

  13. Application of transient ignition model to multi-canister (MCO) accident analysis

    International Nuclear Information System (INIS)

    Kummerer, M.

    1996-01-01

    The potential for ignition of spent nuclear fuel in a Multi-Canister Overpack (MCO) is examined. A transient model is applied to calculate the highest ambient gas temperature outside an MCO wall tube or shipping cask for which a stable temperature condition exists. This integral analysis couples reaction kinetics with a description of the MCO configuration, heat and mass transfer, and fission product phenomena. It thereby allows ignition theory to be applied to various complex scenarios, including MCO water loss accidents and dry MCO air ingression

  14. Demonstrate use of capillary electrophoresis low level transient of anions

    International Nuclear Information System (INIS)

    Moum, Kari-Lye; Solheim, Torill; McElrath, Joel; Frattini, Paul

    2012-09-01

    Capillary Electrophoresis (CE) is a well-known analytical method capable of rapid detection of very low concentration of cations and anionic species such as chloride, sulfate and nitrate. These anions are of crucial importance in reducing the potential of stainless steel components to undergo stress corrosion cracking. Currently, Nuclear Power Plants (NPPs) use Ion Chromatography (IC) as the analytical technique to achieve the required detection levels of ionic species. At the Halden Reactor Project (HRP) IC was replaced by CE in 1996, and since then HRP has gained nearly 20 years of operational experience. During the last 15 years, EPRI has done research on the CE technique and has achieved extensive experience in this area. EPRI has demonstrated detection levels at ppt and sub-ppb levels. This paper presents the ability of the CE technique to follow low level transients of anions in Boiling Water Reactor (BWR) coolant. A transient caused by approx. 10 ppb chloride and sulfate was simulated in an experimental circuit simulating BWR conditions. A series of grab samples were taken and analysed using HRPs CE (Agilent G1600). (authors)

  15. Three dimensional neutronic/thermal-hydraulic coupled simulation of MSR in transient state condition

    International Nuclear Information System (INIS)

    Zhou, Jianjun; Zhang, Daling; Qiu, Suizheng; Su, Guanghui; Tian, Wenxi; Wu, Yingwei

    2015-01-01

    Highlights: • Developed a three dimensional neutronic/thermal-hydraulic coupled transient analysis code for MSR. • Investigated the neutron distribution and thermal-hydraulic characters of the core under transient condition. • Analyzed three different transient conditions of inlet temperature drop, reactivity jump and pump coastdown. - Abstract: MSR (molten salt reactor) use liquid molten salt as coolant and fuel solvent, which was the only one liquid reactor of six Generation IV reactor types. As a liquid reactor the physical property of reactor was significantly influenced by fuel salt flow and the conventional analysis methods applied in solid fuel reactors are not applicable for this type of reactors. The present work developed a three dimensional neutronic/thermal-hydraulic coupled code investigated the neutronics and thermo-hydraulics characteristics of the core in transient condition based on neutron diffusion theory and numerical heat transfer. The code consists of two group neutron diffusion equations for fast and thermal neutron fluxes and six group balance equations for delayed neutron precursors. The code was separately validated by neutron benchmark and flow and heat transfer benchmark. Three different transient conditions was analyzed with inlet temperature drop, reactivity jump and pump coastdown. The results provide some valuable information in design and research this kind of reactor

  16. Three dimensional neutronic/thermal-hydraulic coupled simulation of MSR in transient state condition

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jianjun [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China); College of Mechanical and Power Engineering, China Three Gorges University, No 8, Daxue road, Yichang, Hubei 443002 (China); Zhang, Daling, E-mail: dlzhang@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China); Qiu, Suizheng; Su, Guanghui; Tian, Wenxi; Wu, Yingwei [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China)

    2015-02-15

    Highlights: • Developed a three dimensional neutronic/thermal-hydraulic coupled transient analysis code for MSR. • Investigated the neutron distribution and thermal-hydraulic characters of the core under transient condition. • Analyzed three different transient conditions of inlet temperature drop, reactivity jump and pump coastdown. - Abstract: MSR (molten salt reactor) use liquid molten salt as coolant and fuel solvent, which was the only one liquid reactor of six Generation IV reactor types. As a liquid reactor the physical property of reactor was significantly influenced by fuel salt flow and the conventional analysis methods applied in solid fuel reactors are not applicable for this type of reactors. The present work developed a three dimensional neutronic/thermal-hydraulic coupled code investigated the neutronics and thermo-hydraulics characteristics of the core in transient condition based on neutron diffusion theory and numerical heat transfer. The code consists of two group neutron diffusion equations for fast and thermal neutron fluxes and six group balance equations for delayed neutron precursors. The code was separately validated by neutron benchmark and flow and heat transfer benchmark. Three different transient conditions was analyzed with inlet temperature drop, reactivity jump and pump coastdown. The results provide some valuable information in design and research this kind of reactor.

  17. Analysis of a Plant Transcriptional Regulatory Network Using Transient Expression Systems.

    Science.gov (United States)

    Díaz-Triviño, Sara; Long, Yuchen; Scheres, Ben; Blilou, Ikram

    2017-01-01

    In plant biology, transient expression systems have become valuable approaches used routinely to rapidly study protein expression, subcellular localization, protein-protein interactions, and transcriptional activity prior to in vivo studies. When studying transcriptional regulation, luciferase reporter assays offer a sensitive readout for assaying promoter behavior in response to different regulators or environmental contexts and to confirm and assess the functional relevance of predicted binding sites in target promoters. This chapter aims to provide detailed methods for using luciferase reporter system as a rapid, efficient, and versatile assay to analyze transcriptional regulation of target genes by transcriptional regulators. We describe a series of optimized transient expression systems consisting of Arabidopsis thaliana protoplasts, infiltrated Nicotiana benthamiana leaves, and human HeLa cells to study the transcriptional regulations of two well-characterized transcriptional regulators SCARECROW (SCR) and SHORT-ROOT (SHR) on one of their targets, CYCLIN D6 (CYCD6).Here, we illustrate similarities and differences in outcomes when using different systems. The plant-based systems revealed that the SCR-SHR complex enhances CYCD6 transcription, while analysis in HeLa cells showed that the complex is not sufficient to strongly induce CYCD6 transcription, suggesting that additional, plant-specific regulators are required for full activation. These results highlight the importance of the system and suggest that including heterologous systems, such as HeLa cells, can provide a more comprehensive analysis of a complex gene regulatory network.

  18. RADIO TRANSIENTS FROM THE ACCRETION-INDUCED COLLAPSE OF WHITE DWARFS

    Energy Technology Data Exchange (ETDEWEB)

    Piro, Anthony L.; Kulkarni, S. R., E-mail: piro@caltech.edu [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States)

    2013-01-10

    It has long been expected that in some scenarios when a white dwarf (WD) grows to the Chandrasekhar limit, it can undergo an accretion-induced collapse (AIC) to form a rapidly rotating neutron star. Nevertheless, the detection of such events has so far evaded discovery, likely because the optical, supernova-like emission is expected to be dim and short-lived. Here we propose a novel signature of AIC: a transient radio source lasting for a few months. Rapid rotation along with flux freezing and dynamo action can grow the WD's magnetic field to magnetar strengths during collapse. The spin-down of this newly born magnetar generates a pulsar wind nebula (PWN) within the {approx}10{sup -3}-10{sup -1} M{sub Sun} of ejecta surrounding it. Our calculations show that synchrotron emission from the PWN may be detectable in the radio, even if the magnetar has a rather modest magnetic field of {approx}2 Multiplication-Sign 10{sup 14} G and an initial spin period of {approx}10 ms. An all-sky survey with a detection limit of 1 mJy at 1.4 GHz would see {approx}4(f/10{sup -2}) above threshold at any given time, where f is the ratio of the AIC rate to Type Ia supernova rate. A similar scenario may result from binary neutron stars if some mergers produce massive neutron stars rather than black holes. We conclude with a discussion of the detectability of these types of transient radio sources in an era of facilities with high mapping speeds.

  19. A system for applying rapid warming or cooling stimuli to cells during patch clamp recording or ion imaging.

    Science.gov (United States)

    Reid, G; Amuzescu, B; Zech, E; Flonta, M L

    2001-10-15

    We describe a system for superfusing small groups of cells at a precisely controlled and rapidly adjustable local temperature. Before being applied to the cell or cells under study, solutions are heated or cooled in a chamber of small volume ( approximately 150 microl) and large surface area, sandwiched between four small Peltier elements. The current through the Peltier elements is controlled by a microprocessor using a PID (proportional-integral-derivative) feedback algorithm. The chamber can be heated to at least 60 degrees C and cooled to 0 degrees C, changing its temperature at a maximum rate of about 7 degrees C per second; temperature ramps can be followed under feedback control at up to 4 degrees C per second. Temperature commands can be applied from the digital-to-analogue converter of any laboratory interface or generated digitally by the microprocessor. The peak-to-peak noise contributed by the system does not exceed that contributed by a patch pipette, holder and headstage, making it suitable for single channel as well as whole cell recordings.

  20. Shock-induced thermal wave propagation and response analysis of a viscoelastic thin plate under transient heating loads

    Science.gov (United States)

    Li, Chenlin; Guo, Huili; Tian, Xiaogeng

    2018-04-01

    This paper is devoted to the thermal shock analysis for viscoelastic materials under transient heating loads. The governing coupled equations with time-delay parameter and nonlocal scale parameter are derived based on the generalized thermo-viscoelasticity theory. The problem of a thin plate composed of viscoelastic material, subjected to a sudden temperature rise at the boundary plane, is solved by employing Laplace transformation techniques. The transient responses, i.e. temperature, displacement, stresses, heat flux as well as strain, are obtained and discussed. The effects of time-delay and nonlocal scale parameter on the transient responses are analyzed and discussed. It can be observed that: the propagation of thermal wave is dynamically smoothed and changed with the variation of time-delay; while the displacement, strain, and stress can be rapidly reduced by nonlocal scale parameter, which can be viewed as an important indicator for predicting the stiffness softening behavior for viscoelastic materials.

  1. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  2. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  3. Transient flow characteristics of a high speed rotary valve

    Science.gov (United States)

    Browning, Patrick H.

    Pressing economic and environmental concerns related to the performance of fossil fuel burning internal combustion engines have revitalized research in more efficient, cleaner burning combustion methods such as homogeneous charge compression ignition (HCCI). Although many variations of such engines now exist, several limiting factors have restrained the full potential of HCCI. A new method patented by West Virginia University (WVU) called Compression Ignition by Air Injection (CIBAI) may help broaden the range of effective HCCI operation. The CIBAI process is ideally facilitated by operating two synchronized piston-cylinders mounted head-to-head with one of the cylinders filled with a homogeneous mixture of air and fuel and the other cylinder filled with air. A specialized valve called the cylinder connecting valve (CCV) separates the two cylinders, opens just before reaching top dead center (TDC), and allows the injection air into the charge to achieve autoignition. The CCV remains open during the entire power stroke such that upon ignition the rapid pressure rise in the charge cylinder forces mass flow back through the CCV into the air-only cylinder. The limited mass transfer between the cylinders through the CCV limits the theoretical auto ignition timing capabilities and thermal efficiency of the CIBAI cycle. Research has been performed to: (1) Experimentally measure the transient behavior of a potential CCV design during valve opening between two chambers maintained at constant pressure and again at constant volume; (2) Develop a modified theoretical CCV mass flow model based upon the measured cold flow valve performance that is capable of predicting the operating conditions required for successful mixture autoignition; (3) Make recommendations for future CCV designs to maximize CIBAI combustion range. Results indicate that the modified-ball CCV design offers suitable transient flow qualities required for application to the CIBAI concept. Mass injection events

  4. Modular time division multiplexer: Efficient simultaneous characterization of fast and slow transients in multiple samples

    Science.gov (United States)

    Kim, Stephan D.; Luo, Jiajun; Buchholz, D. Bruce; Chang, R. P. H.; Grayson, M.

    2016-09-01

    A modular time division multiplexer (MTDM) device is introduced to enable parallel measurement of multiple samples with both fast and slow decay transients spanning from millisecond to month-long time scales. This is achieved by dedicating a single high-speed measurement instrument for rapid data collection at the start of a transient, and by multiplexing a second low-speed measurement instrument for slow data collection of several samples in parallel for the later transients. The MTDM is a high-level design concept that can in principle measure an arbitrary number of samples, and the low cost implementation here allows up to 16 samples to be measured in parallel over several months, reducing the total ensemble measurement duration and equipment usage by as much as an order of magnitude without sacrificing fidelity. The MTDM was successfully demonstrated by simultaneously measuring the photoconductivity of three amorphous indium-gallium-zinc-oxide thin films with 20 ms data resolution for fast transients and an uninterrupted parallel run time of over 20 days. The MTDM has potential applications in many areas of research that manifest response times spanning many orders of magnitude, such as photovoltaics, rechargeable batteries, amorphous semiconductors such as silicon and amorphous indium-gallium-zinc-oxide.

  5. DISCOVERY OF A TRANSIENT GAMMA-RAY COUNTERPART TO FRB 131104

    International Nuclear Information System (INIS)

    DeLaunay, J. J.; Murase, K.; Mészáros, P.; Keivani, A.; Messick, C.; Mostafá, M. A.; Oikonomou, F.; Tešić, G.; Turley, C. F.; Fox, D. B.

    2016-01-01

    We report our discovery in Swift satellite data of a transient gamma-ray counterpart (3.2 σ confidence) to the fast radio burst (FRB) FRB 131104, the first such counterpart to any FRB. The transient has a duration T _9_0 ≳ 100 s and a fluence S_γ ≈ 4 × 10"−"6 erg cm"−"2, increasing the energy budget for this event by more than a billion times; at the nominal z ≈ 0.55 redshift implied by its dispersion measure, the burst’s gamma-ray energy output is E_γ ≈ 5 × 10"5"1 erg. The observed radio to gamma-ray fluence ratio for FRB 131104 is consistent with a lower limit we derive from Swift observations of another FRB, which is not detected in gamma-rays, and with an upper limit previously derived for the brightest gamma-ray flare from SGR 1806−20, which was not detected in the radio. X-ray, ultraviolet, and optical observations beginning two days after the FRB do not reveal any associated afterglow, supernova, or transient; Swift observations exclude association with the brightest 65% of Swift gamma-ray burst (GRB) X-ray afterglows, while leaving the possibility of an associated supernova at much more than 10% the FRB’s nominal distance, D ≳ 320 Mpc, largely unconstrained. Transient high-luminosity gamma-ray emission arises most naturally in a relativistic outflow or shock breakout, such as, for example, from magnetar flares, GRBs, relativistic supernovae, and some types of galactic nuclear activity. Our discovery thus bolsters the case for an extragalactic origin for some FRBs and suggests that future rapid-response observations might identify long-lived counterparts, resolving the nature of these mysterious phenomena and realizing their promise as probes of cosmology and fundamental physics.

  6. DISCOVERY OF A TRANSIENT GAMMA-RAY COUNTERPART TO FRB 131104

    Energy Technology Data Exchange (ETDEWEB)

    DeLaunay, J. J.; Murase, K.; Mészáros, P.; Keivani, A.; Messick, C.; Mostafá, M. A.; Oikonomou, F.; Tešić, G.; Turley, C. F. [Department of Physics, Pennsylvania State University, University Park, PA 16802 (United States); Fox, D. B., E-mail: jjd330@psu.edu [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States)

    2016-11-20

    We report our discovery in Swift satellite data of a transient gamma-ray counterpart (3.2 σ confidence) to the fast radio burst (FRB) FRB 131104, the first such counterpart to any FRB. The transient has a duration T {sub 90} ≳ 100 s and a fluence S{sub γ} ≈ 4 × 10{sup −6} erg cm{sup −2}, increasing the energy budget for this event by more than a billion times; at the nominal z ≈ 0.55 redshift implied by its dispersion measure, the burst’s gamma-ray energy output is E{sub γ} ≈ 5 × 10{sup 51} erg. The observed radio to gamma-ray fluence ratio for FRB 131104 is consistent with a lower limit we derive from Swift observations of another FRB, which is not detected in gamma-rays, and with an upper limit previously derived for the brightest gamma-ray flare from SGR 1806−20, which was not detected in the radio. X-ray, ultraviolet, and optical observations beginning two days after the FRB do not reveal any associated afterglow, supernova, or transient; Swift observations exclude association with the brightest 65% of Swift gamma-ray burst (GRB) X-ray afterglows, while leaving the possibility of an associated supernova at much more than 10% the FRB’s nominal distance, D ≳ 320 Mpc, largely unconstrained. Transient high-luminosity gamma-ray emission arises most naturally in a relativistic outflow or shock breakout, such as, for example, from magnetar flares, GRBs, relativistic supernovae, and some types of galactic nuclear activity. Our discovery thus bolsters the case for an extragalactic origin for some FRBs and suggests that future rapid-response observations might identify long-lived counterparts, resolving the nature of these mysterious phenomena and realizing their promise as probes of cosmology and fundamental physics.

  7. Environmental, Transient, Three-Dimensional, Hydrothermal, Mass Transport Code - FLESCOT

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Yasuo [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bao, Jie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glass, Kevin A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eyler, L. L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Okumura, Masahiko [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-28

    The purpose of the project was to modify and apply the transient, three-dimensional FLESCOT code to be able to effectively simulate cesium behavior in Fukushima lakes/dam reservoirs, river mouths, and coastal areas. The ultimate objective of the FLESCOT simulation is to predict future changes of cesium accumulation in Fukushima area reservoirs and costal water. These evaluation results will assist ongoing and future environmental remediation activities and policies in a systematic and comprehensive manner.

  8. Terahertz time-domain attenuated total reflection spectroscopy applied to the rapid discrimination of the botanical origin of honeys

    Science.gov (United States)

    Liu, Wen; Zhang, Yuying; Yang, Si; Han, Donghai

    2018-05-01

    A new technique to identify the floral resources of honeys is demanded. Terahertz time-domain attenuated total reflection spectroscopy combined with chemometrics methods was applied to discriminate different categorizes (Medlar honey, Vitex honey, and Acacia honey). Principal component analysis (PCA), cluster analysis (CA) and partial least squares-discriminant analysis (PLS-DA) have been used to find information of the botanical origins of honeys. Spectral range also was discussed to increase the precision of PLS-DA model. The accuracy of 88.46% for validation set was obtained, using PLS-DA model in 0.5-1.5 THz. This work indicated terahertz time-domain attenuated total reflection spectroscopy was an available approach to evaluate the quality of honey rapidly.

  9. Intermolecular interaction of photoexcited Cu(/TMpy-P4) with water studied by transient resonance Raman and picosecond absorption spectroscopies

    NARCIS (Netherlands)

    Kruglik, S.; Kruglik, Sergei G.; Ermolenkov, Vladimir V.; Shvedko, Alexander G.; Orlovich, Valentine A.; Galievsky, Victor A.; Chirvony, Vladimir S.; Otto, Cornelis; Turpin, Pierre-Yves

    1997-01-01

    photoinduced complex between Cu(TMpy-P4) and water molecules, reversibly axially coordinated to the central metal, was observed in picosecond transient absorption and nanosecond resonance Raman experiments. This complex is rapidly created (τ1 = 15 ± 5 ps) in the excited triplet (π, π*) state of

  10. Transient-Switch-Signal Suppressor

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Circuit delays transmission of switch-opening or switch-closing signal until after preset suppression time. Used to prevent transmission of undesired momentary switch signal. Basic mode of operation simple. Beginning of switch signal initiates timing sequence. If switch signal persists after preset suppression time, circuit transmits switch signal to external circuitry. If switch signal no longer present after suppression time, switch signal deemed transient, and circuit does not pass signal on to external circuitry, as though no transient switch signal. Suppression time preset at value large enough to allow for damping of underlying pressure wave or other mechanical transient.

  11. Summary of transient analysis

    International Nuclear Information System (INIS)

    Saha, P.

    1984-01-01

    This chapter reviews the papers on the pressurized water reactor (PWR) and boiling water reactor (BWR) transient analyses given at the American Nuclear Society Topical Meeting on Anticipated and Abnormal Plant Transients in Light Water Reactors. Most of the papers were based on the systems calculations performed using the TRAC-PWR, RELAP5 and RETRAN codes. The status of the nuclear industry in the code applications area is discussed. It is concluded that even though comprehensive computer codes are available for plant transient analysis, there is still a need to exercise engineering judgment, simpler tools and even hand calculations to supplement these codes

  12. Application of positron annihilation lifetime technique to the study of deep level transients in semiconductors

    Science.gov (United States)

    Deng, A. H.; Shan, Y. Y.; Fung, S.; Beling, C. D.

    2002-03-01

    Unlike its conventional applications in lattice defect characterization, positron annihilation lifetime technique was applied to study temperature-dependent deep level transients in semiconductors. Defect levels in the band gap can be determined as they are determined by conventional deep level transient spectroscopy (DLTS) studies. The promising advantage of this application of positron annihilation over the conventional DLTS is that it could further extract extra microstructure information of deep-level defects, such as whether a deep level defect is vacancy related or not. A demonstration of EL2 defect level transient study in GaAs was shown and the EL2 level of 0.82±0.02 eV was obtained by a standard Arrhenius analysis, similar to that in conventional DLTS studies.

  13. Experience with transients in German NPPs

    International Nuclear Information System (INIS)

    Lindauer, E.

    1984-01-01

    This chapter examines reactor accidents in the Federal Republic of Germany based on the formal reporting system for licensee event reports (LERs) and a special investigation on all unplanned power variations in 3 PWRs. The significant transients experienced by BWR type reactors are analyzed. The main goal is to find weak points which caused the transient or influenced its course in an unfavorable way in order to improve the affected plant and others. The complete survey of all transients, with normally little or no safety relevance, allows statistical evaluations and the analysis of trends. It is concluded that significant transients were mainly experienced at older plants, whereas plants of an advanced design produced very few significant transients. The most frequent human errors which lead to transients are failure search in electronic systems and errors during design and commissioning

  14. Analysis of the Mannshan Unit 2 full load rejection transient

    International Nuclear Information System (INIS)

    Kang, J.C.; Pei, B.S.; Yu, G.P.; Yuann, R.Y.

    1987-01-01

    Mannshan Unit 2 is a Westinghouse three-loop pressurized water reactor with a rated core power of 2775 MW(thermal) and a rated core flow of 4702 kg/s. Before full power operation, a planned net load rejection was performed during the startup test by opening the main transformer highside breakers. The generator power rapidly reduced to station load. All 16 steam dump valves immediately popped open, and control bank-D rods automatically stepped in as the temperature difference T/sub avg/ - T/sub ref/ reached a programmed 2.8 0 C. Nuclear power decreased smoothly as control rods were inserted into the core. The pressurizer pressure and liquid levels also dropped. Neither safety injection nor reactor trip occurred during this transient. The test was done to verify that the whole system would function properly under a transient to keep the reactor from scramming and that the vessel integrity would also be protected. In this study, which is the preliminary stage of RELAP5/MOD2 transient simulation of the Mannshan PWR plants, system thermal-hydraulic response is tested first and isolated from the neutronic effects. The variation of core power versus time curve was extracted from the power test data to serve as a time varying boundary condition. The comparison of the analytical results of four major parameters (pressurizer pressure, average temperature of the core, steam dump flow rate, and feedwater flow rate) from RELAP5/MOD2 and the power test data is illustrated

  15. Time-resolved photoluminescence of Ga(NAsP) multiple quantum wells grown on Si substrate: Effects of rapid thermal annealing

    Energy Technology Data Exchange (ETDEWEB)

    Woscholski, R., E-mail: ronja.woscholski@physik.uni-marburg.de; Shakfa, M.K.; Gies, S.; Wiemer, M.; Rahimi-Iman, A.; Zimprich, M.; Reinhard, S.; Jandieri, K.; Baranovskii, S.D.; Heimbrodt, W.; Volz, K.; Stolz, W.; Koch, M.

    2016-08-31

    Time-resolved photoluminescence (TR-PL) spectroscopy has been used to study the impact of rapid thermal annealing (RTA) on the optical properties and carrier dynamics in Ga(NAsP) multiple quantum well heterostructures (MQWHs) grown on silicon substrates. TR-PL measurements reveal an enhancement in the PL efficiency when the RTA temperature is increased up to 925 °C. Then, the PL intensity dramatically decreases with the annealing temperature. This behavior is explained by the variation of the disorder degree in the studied structures. The analysis of the low-temperature emission-energy-dependent PL decay time enables us to characterize the disorder in the Ga(NAsP) MQWHs. The theoretically extracted energy-scales of disorder confirm the experimental observations. - Highlights: • Ga(NAsP) multiple quantum well heterostructures (MQWHs) grown on silicon substrates • Impact of rapid thermal annealing on the optical properties and carrier dynamics • Time resolved photoluminescence spectroscopy was applied. • PL transients became continuously faster with increasing annealing temperature. • Enhancement in the PL efficiency with increasing annealing temperature up to 925 °C.

  16. Time-resolved photoluminescence of Ga(NAsP) multiple quantum wells grown on Si substrate: Effects of rapid thermal annealing

    International Nuclear Information System (INIS)

    Woscholski, R.; Shakfa, M.K.; Gies, S.; Wiemer, M.; Rahimi-Iman, A.; Zimprich, M.; Reinhard, S.; Jandieri, K.; Baranovskii, S.D.; Heimbrodt, W.; Volz, K.; Stolz, W.; Koch, M.

    2016-01-01

    Time-resolved photoluminescence (TR-PL) spectroscopy has been used to study the impact of rapid thermal annealing (RTA) on the optical properties and carrier dynamics in Ga(NAsP) multiple quantum well heterostructures (MQWHs) grown on silicon substrates. TR-PL measurements reveal an enhancement in the PL efficiency when the RTA temperature is increased up to 925 °C. Then, the PL intensity dramatically decreases with the annealing temperature. This behavior is explained by the variation of the disorder degree in the studied structures. The analysis of the low-temperature emission-energy-dependent PL decay time enables us to characterize the disorder in the Ga(NAsP) MQWHs. The theoretically extracted energy-scales of disorder confirm the experimental observations. - Highlights: • Ga(NAsP) multiple quantum well heterostructures (MQWHs) grown on silicon substrates • Impact of rapid thermal annealing on the optical properties and carrier dynamics • Time resolved photoluminescence spectroscopy was applied. • PL transients became continuously faster with increasing annealing temperature. • Enhancement in the PL efficiency with increasing annealing temperature up to 925 °C

  17. Transient Three-Dimensional Side Load Analysis of a Film Cooled Nozzle

    Science.gov (United States)

    Wang, Ten-See; Guidos, Mike

    2008-01-01

    Transient three-dimensional numerical investigations on the side load physics for an engine encompassing a film cooled nozzle extension and a regeneratively cooled thrust chamber, were performed. The objectives of this study are to identify the three-dimensional side load physics and to compute the associated aerodynamic side load using an anchored computational methodology. The computational methodology is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, and a transient inlet history based on an engine system simulation. Ultimately, the computational results will be provided to the nozzle designers for estimating of effect of the peak side load on the nozzle structure. Computations simulating engine startup at ambient pressures corresponding to sea level and three high altitudes were performed. In addition, computations for both engine startup and shutdown transients were also performed for a stub nozzle, operating at sea level. For engine with the full nozzle extension, computational result shows starting up at sea level, the peak side load occurs when the lambda shock steps into the turbine exhaust flow, while the side load caused by the transition from free-shock separation to restricted-shock separation comes at second; and the side loads decreasing rapidly and progressively as the ambient pressure decreases. For the stub nozzle operating at sea level, the computed side loads during both startup and shutdown becomes very small due to the much reduced flow area.

  18. Rapid transient production in plants by replicating and non-replicating vectors yields high quality functional anti-HIV antibody.

    Directory of Open Access Journals (Sweden)

    Frank Sainsbury

    2010-11-01

    Full Text Available The capacity of plants and plant cells to produce large amounts of recombinant protein has been well established. Due to advantages in terms of speed and yield, attention has recently turned towards the use of transient expression systems, including viral vectors, to produce proteins of pharmaceutical interest in plants. However, the effects of such high level expression from viral vectors and concomitant effects on host cells may affect the quality of the recombinant product.To assess the quality of antibodies transiently expressed to high levels in plants, we have expressed and characterised the human anti-HIV monoclonal antibody, 2G12, using both replicating and non-replicating systems based on deleted versions of Cowpea mosaic virus (CPMV RNA-2. The highest yield (approximately 100 mg/kg wet weight leaf tissue of affinity purified 2G12 was obtained when the non-replicating CPMV-HT system was used and the antibody was retained in the endoplasmic reticulum (ER. Glycan analysis by mass-spectrometry showed that the glycosylation pattern was determined exclusively by whether the antibody was retained in the ER and did not depend on whether a replicating or non-replicating system was used. Characterisation of the binding and neutralisation properties of all the purified 2G12 variants from plants showed that these were generally similar to those of the Chinese hamster ovary (CHO cell-produced 2G12.Overall, the results demonstrate that replicating and non-replicating CPMV-based vectors are able to direct the production of a recombinant IgG similar in activity to the CHO-produced control. Thus, a complex recombinant protein was produced with no apparent effect on its biochemical properties using either high-level expression or viral replication. The speed with which a recombinant pharmaceutical with excellent biochemical characteristics can be produced transiently in plants makes CPMV-based expression vectors an attractive option for

  19. Real-time simulation of thermal stresses and creep in plates subjected to transient heat input

    DEFF Research Database (Denmark)

    Hattel, Jesper Henri; Jacobsen, Torben Krogsdal; Hansen, P.N.

    1997-01-01

    -difference approach. It applies a general formulation which takes into account nonconstant material properties (e.g. temperature, material, or time dependency), heat-transfer coefficients, and creep. The temperature calculation applies a one-dimensional numerical model, whereas the stress analysis is semi......This paper presents a novel numerical technique for solving the temperature and stress fields in a plate subjected to arbitrarily varying transient boundary conditions (transient temperature and heat-flux variations) on a surface. The numerical method is based on the control-volume finite......-two-dimensional. Both plane stress and plane strain conditions are considered as extreme cases. It is shown that, by using the developed numerical technique, very fast real-time simulations can be performed. The method has proved its applicability in e.g. high-pressure die-casting, and applications to this industrial...

  20. Nuclear power plant transients: where are we

    International Nuclear Information System (INIS)

    Majumdar, D.

    1984-05-01

    This document is in part a postconference review and summary of the American Nuclear Society sponsored Anticipated and Abnormal Plant Transients in Light Water Reactors Conference held in Jackson, Wyoming, September 26-29, 1983, and in part a reflection upon the issues of plant transients and their impact on the viability of nuclear power. This document discusses state-of-the-art knowledge, deficiencies, and future directions in the plant transients area as seen through this conference. It describes briefly what was reported in this conference, emphasizes areas where it is felt there is confidence in the nuclear industry, and also discusses where the experts did not have a consensus. Areas covered in the document include major issues in operational transients, transient management, transient events experience base, the status of the analytical tools and their capabilities, probabilistic risk assessment applications in operational transients, and human factors impact on plant transients management

  1. PWR systems transient analysis

    International Nuclear Information System (INIS)

    Kennedy, M.F.; Peeler, G.B.; Abramson, P.B.

    1985-01-01

    Analysis of transients in pressurized water reactor (PWR) systems involves the assessment of the response of the total plant, including primary and secondary coolant systems, steam piping and turbine (possibly including the complete feedwater train), and various control and safety systems. Transient analysis is performed as part of the plant safety analysis to insure the adequacy of the reactor design and operating procedures and to verify the applicable plant emergency guidelines. Event sequences which must be examined are developed by considering possible failures or maloperations of plant components. These vary in severity (and calculational difficulty) from a series of normal operational transients, such as minor load changes, reactor trips, valve and pump malfunctions, up to the double-ended guillotine rupture of a primary reactor coolant system pipe known as a Large Break Loss of Coolant Accident (LBLOCA). The focus of this paper is the analysis of all those transients and accidents except loss of coolant accidents

  2. Transient period analysis of a distillation column using a control approach with distributed heating; Analise do periodo transiente de uma coluna de destilacao usando abordagem de controle com aquecimento distribuido

    Energy Technology Data Exchange (ETDEWEB)

    Werle, Leandro O.; Steinmacher, Fernanda R.; Marangoni, Cintia; Araujo, Pedro H.H de; Machado, Ricardo A.F.; Sayer, Claudia [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil)

    2008-07-01

    The distillation process is widely used in oil refineries. The non-linear behavior, the coupling between variables and the high time constants, associated to the response delay, result in long transient periods operating out of the desired conditions, obtaining out of specification products. Even with several researches in more and more complex control approaches, few works approached the aspect of transient minimization. Moreover, the control of distillation columns is carried out centralized at the bottom and the top. In the present work the effect of the distributed control is evaluated, through the electric resistance located on an intermediate tray of the column. The objective of the work is reducing the operation transients when a disturbance is applied. For the current study, experiments have been carried out in a pilot distillation unit composed of 13 trays and instrumented in fieldbus, processing an ethanol-water mixture. Step disturbances of 50% in the feeding flow rate of have been carried out. The comparison of the results showed that the introduction of the distributed heating throughout the column allows faster dynamics, revealing itself as a valid option for the transient reduction. (author)

  3. Transient osteoporosis of the hip

    International Nuclear Information System (INIS)

    McWalter, Patricia; Hassan Ahmed

    2007-01-01

    Transient osteoporosis of the hip is an uncommon cause of hip pain, mostly affecting healthy middle-aged men and also women in the third trimester of pregnancy. We present a case of transient osteoporosis of the hip in a 33-year-old non-pregnant female patient. This case highlights the importance of considering a diagnosis of transient osteoporosis of the hip in patients who present with hip pain. (author)

  4. Implications of Jeffreys-Lomnitz Transient Creep

    Science.gov (United States)

    Strick, Ellis

    1984-01-01

    In 1958 Jeffreys proposed a power law generalization of the logarithmic transient creep earlier attributed to Lomnitz. Although Jeffreys' power law form was admittedly defective in that it became unbounded at infinite time, he did apply it to the viscoelastic behavior of the earth-moon system. Since then it has been successfully applied by many investigators to mantle rehology and Chandler wobble. Experimental seismic studies indicate that most rock types exhibit the almost constant Q behavior which Lomnitz showed to be associated with his logarithmic creep. In this paper, we study not only the Q behavior related to Jeffreys' power law creep but also other mechanical properties such as a precise spring-dashpot ladder network realization are developed. In addition, a very simple physically realizable modification of this ladder network leads to a boundedness at long times of Jeffreys' creep in a manner which does not affect his successful application at finite times.

  5. Transient electromagnetic scattering on anisotropic media

    International Nuclear Information System (INIS)

    Stewart, R.D.

    1990-01-01

    This dissertation treats the problem of transient scattering of obliquely incident electromagnetic plane waves on a stratified anisotropic dielectric slab. Scattering operators are derived for the reflective response of the medium. The internal fields are calculated. Wave splitting and invariant imbedding techniques are used. These techniques are first presented for fields normally incident on a stratified, isotropic dielectric medium. The techniques of wave splitting and invariant imbedding are applied to normally incident plane waves on an anisotropic medium. An integro-differential equation is derived for the reflective response and the direct and inverse scattering problems are discussed. These techniques are applied to the case of obliquely incident plane waves. The reflective response is derived and the direct and inverse problems discussed and compared to those for the normal incidence case. The internal fields are investigated for the oblique incidence via a Green's function approach. A numerical scheme is presented to calculate the Green's function. Finally, symmetry relations of the reflective response are discussed

  6. Study of transient current induced by heavy-ion microbeams in Si and GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Hirao, Toshio; Nashiyama, Isamu; Kamiya, Tomihiro; Suda, Tamotu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    Heavy-ion microbeams were applied to the study of mechanism of single event upset (SEU). Transient current induced in p{sup +}n junction diodes by strike of heavy ion microbeam were measured by using a high-speed digitizing sampling system. (author)

  7. A COMETHE version with transient capability

    International Nuclear Information System (INIS)

    Vliet, J. van; Lebon, G.; Mathieu, P.

    1980-01-01

    A version of the COMETHE code is under development to simulate transient situations. This paper focuses on some aspects of the transient heat transfer models. Initially the coupling between transient heat transfer and other thermomechanical models is discussed. An estimation of the thermal characteristic times shows that the cladding temperatures are often in quasi-steady state. In order to reduce the computing time, calculations are therefore switched from a transient to a quasi-static numerical procedure as soon as such a quasi-equilibrium is detected. The temperature calculation is performed by use of the Lebon-Lambermont restricted variational principle, with piecewise polynoms as trial functions. The method has been checked by comparison with some exact results and yields good agreement for transient as well as for quasi-static situations. This method therefore provides a valuable tool for the simulation of the transient behaviour of nuclear reactor fuel rods. (orig.)

  8. Revealing the cluster of slow transients behind a large slow slip event.

    Science.gov (United States)

    Frank, William B; Rousset, Baptiste; Lasserre, Cécile; Campillo, Michel

    2018-05-01

    Capable of reaching similar magnitudes to large megathrust earthquakes [ M w (moment magnitude) > 7], slow slip events play a major role in accommodating tectonic motion on plate boundaries through predominantly aseismic rupture. We demonstrate here that large slow slip events are a cluster of short-duration slow transients. Using a dense catalog of low-frequency earthquakes as a guide, we investigate the M w 7.5 slow slip event that occurred in 2006 along the subduction interface 40 km beneath Guerrero, Mexico. We show that while the long-period surface displacement, as recorded by Global Positioning System, suggests a 6-month duration, the motion in the direction of tectonic release only sporadically occurs over 55 days, and its surface signature is attenuated by rapid relocking of the plate interface. Our proposed description of slow slip as a cluster of slow transients forces us to re-evaluate our understanding of the physics and scaling of slow earthquakes.

  9. ORTAP: a nuclear steam supply system simulation for the dynamic analysis of high temperature gas cooled reactor transients

    International Nuclear Information System (INIS)

    Cleveland, J.C.; Hedrick, R.A.; Ball, S.J.; Delene, J.G.

    1977-01-01

    ORTAP was developed to predict the dynamic behavior of the high temperature gas cooled reactor (HTGR) Nuclear Steam Supply System for normal operational transients and postulated accident conditions. It was developed for the Nuclear Regulatory Commission (NRC) as an independent means of obtaining conservative predictions of the transient response of HTGRs over a wide range of conditions. The approach has been to build sufficient detail into the component models so that the coupling between the primary and secondary systems can be accurately represented and so that transients which cover a wide range of conditions can be simulated. System components which are modeled in ORTAP include the reactor core, a typical reheater and steam generator module, a typical helium circulator and circulator turbine and the turbine generator plant. The major plant control systems are also modeled. Normal operational transients which can be analyzed with ORTAP include reactor start-up and shutdown, normal and rapid load changes. Upset transients which can be analyzed with ORTAP include reactor trip, turbine trip and sudden reduction in feedwater flow. ORTAP has also been used to predict plant response to emergency or faulted conditions such as primary system depressurization, loss of primary coolant flow and uncontrolled removal of control poison from the reactor core

  10. Transient and localized processes in the magnetotail: a review

    Directory of Open Access Journals (Sweden)

    A. S. Sharma

    2008-05-01

    Full Text Available Many phenomena in the Earth's magnetotail have characteristic temporal scales of several minutes and spatial scales of a few Earth radii (RE. Examples of such transient and localized mesoscale phenomena are bursty bulk flows, beamlets, energy dispersed ion beams, flux ropes, traveling compression regions, night-side flux transfer events, and rapid flappings of the current sheet. Although most of these observations are linked to specific interpretations or theoretical models they are inter-related and can be the different aspects of a physical process or origin. Recognizing the inter-connected nature of the different transient and localized phenomena in the magnetotail, this paper reviews their observations by highlighting their important characteristics, with emphasis on the new results from Cluster multipoint observations. The multi-point Cluster measurements have provided, for the first time, the ability to distinguish between temporal and spatial variations, and to resolve spatial structures. Some examples of the new results are: flux ropes with widths of 0.3 RE, transient field aligned currents associated with bursty bulk flows and connected to the Hall current at the magnetic reconnection, flappings of the magnetotail current sheet with time scales of 100 s–10 min and thickness of few thousand km, and particle energization including velocity and time dispersed ion structures with the latter having durations of 1–3 min. The current theories of these transient and localized processes are based largely on magnetic reconnection, although the important role of the interchange and other plasma modes are now well recognized. On the kinetic scale, the energization of particles takes place near the magnetic X-point by non-adiabatic processes and wave-particle interactions. The theory, modeling and simulations of the plasma and field signatures are reviewed and the links among the different observational

  11. Transient and localized processes in the magnetotail: a review

    Directory of Open Access Journals (Sweden)

    A. S. Sharma

    2008-05-01

    Full Text Available Many phenomena in the Earth's magnetotail have characteristic temporal scales of several minutes and spatial scales of a few Earth radii (RE. Examples of such transient and localized mesoscale phenomena are bursty bulk flows, beamlets, energy dispersed ion beams, flux ropes, traveling compression regions, night-side flux transfer events, and rapid flappings of the current sheet. Although most of these observations are linked to specific interpretations or theoretical models they are inter-related and can be the different aspects of a physical process or origin. Recognizing the inter-connected nature of the different transient and localized phenomena in the magnetotail, this paper reviews their observations by highlighting their important characteristics, with emphasis on the new results from Cluster multipoint observations. The multi-point Cluster measurements have provided, for the first time, the ability to distinguish between temporal and spatial variations, and to resolve spatial structures. Some examples of the new results are: flux ropes with widths of 0.3 RE, transient field aligned currents associated with bursty bulk flows and connected to the Hall current at the magnetic reconnection, flappings of the magnetotail current sheet with time scales of 100 s–10 min and thickness of few thousand km, and particle energization including velocity and time dispersed ion structures with the latter having durations of 1–3 min. The current theories of these transient and localized processes are based largely on magnetic reconnection, although the important role of the interchange and other plasma modes are now well recognized. On the kinetic scale, the energization of particles takes place near the magnetic X-point by non-adiabatic processes and wave-particle interactions. The theory, modeling and simulations of the plasma and field signatures are reviewed and the links among the different observational concepts and the theoretical frameworks

  12. Discovery of a Transient Magnetar: XTE J1810-197

    Science.gov (United States)

    Ibrahim, Alaa I.; Markwardt, Craig B.; Swank, Jean H.; Ransom, Scott; Roberts, Mallory; Kaspi, Victoria; Woods, Peter M.; Safi-Harb, Samar; Balman, Solen; Parke, William C.

    2004-01-01

    We report the discovery of a new X-ray pulsar, XTE J1810-197, that was serendipitously discovered on 2003 July 15 by the Rossi X-Ray Timing Explorer (RXTE) while observing the soft gamma repeater SGR 1806-20. The pulsar has a 5.54 s spin period, a soft X-ray spectrum (with a photon index of approx. = 4). and is detectable in earlier RXTE observations back to 2003 January but not before. These show that a transient outburst began between 2002 November 17 and 2003 January 23 and that the source's persistent X-ray flux has been declining since then. The pulsar exhibits a high spin-down rate P approx.= l0(exp -11) s/s with no evidence of Doppler shifts due to a binary companion. The rapid spin-down rate and slow spin period imply a supercritical characteristic magnetic field B approx. = 3 x l0(exp 14) G and a young age tau less than or = 7600 yr. Follow-up Chandra observations provided an accurate position of the source. Within its error radius, the 1.5 m Russian-Turkish Optical Telescope found a limiting magnitude R(sub c) = 21.5. All such properties are strikingly similar to those of anomalous X-ray pulsars ad soft gamma repeaters, providing strong evidence that the source is a new magnetar. However, archival ASCA and ROSAT observations found the source nearly 2 orders of magnitude fainter. This transient behavior and the observed long-term flux variability of the source in absence of an observed SGR-like burst activity make it the first confirmed transient magnetar and suggest that other neutron stars that share the properties of XTE 51810- 197 during its inactive phase may be unidentified transient magnetars awaiting detection via a similar activity. This implies a larger population of magnetars than previously surmised and a possible evolutionary connection between magnetars and other neutron star families. Subject headings: pulsars: general -pulsars: individual (XTE 51810- 197) - stars: magnetic fields -

  13. Research of the transient management in TQNPC

    International Nuclear Information System (INIS)

    Guo Longzhang; Lin Chuanqing

    2008-01-01

    Transient management is the basic technical subject in nuclear power plant. Since the Third Qinshan nuclear power company (TQNPC) successful completes the commissioning in 2003, the transient management work start at the transient management item selection and the flow definition. Now TQNPC have a complete transient management system and the management flow. In the last two years, TNQPC have finished the historic transient data collection for two units, and confirmed that the plant's key systems and equipments are at safe state. The development of the transient management subject would build a reliable foundation for the plant safe operation, plant lifetime management and periodic safety review. (author)

  14. Compressive Transient Imaging

    KAUST Repository

    Sun, Qilin

    2017-04-01

    High resolution transient/3D imaging technology is of high interest in both scientific research and commercial application. Nowadays, all of the transient imaging methods suffer from low resolution or time consuming mechanical scanning. We proposed a new method based on TCSPC and Compressive Sensing to achieve a high resolution transient imaging with a several seconds capturing process. Picosecond laser sends a serious of equal interval pulse while synchronized SPAD camera\\'s detecting gate window has a precise phase delay at each cycle. After capturing enough points, we are able to make up a whole signal. By inserting a DMD device into the system, we are able to modulate all the frames of data using binary random patterns to reconstruct a super resolution transient/3D image later. Because the low fill factor of SPAD sensor will make a compressive sensing scenario ill-conditioned, We designed and fabricated a diffractive microlens array. We proposed a new CS reconstruction algorithm which is able to denoise at the same time for the measurements suffering from Poisson noise. Instead of a single SPAD senor, we chose a SPAD array because it can drastically reduce the requirement for the number of measurements and its reconstruction time. Further more, it not easy to reconstruct a high resolution image with only one single sensor while for an array, it just needs to reconstruct small patches and a few measurements. In this thesis, we evaluated the reconstruction methods using both clean measurements and the version corrupted by Poisson noise. The results show how the integration over the layers influence the image quality and our algorithm works well while the measurements suffer from non-trival Poisson noise. It\\'s a breakthrough in the areas of both transient imaging and compressive sensing.

  15. Thermoregulatory and Cardiovascular Consequences of a Transient Thyrotoxicosis and Recovery in Male Mice.

    Science.gov (United States)

    Hoefig, Carolin S; Harder, Lisbeth; Oelkrug, Rebecca; Meusel, Moritz; Vennström, Björn; Brabant, Georg; Mittag, Jens

    2016-07-01

    Thyroid hormones play a major role in body homeostasis, regulating energy expenditure and cardiovascular function. Given that obese people or athletes might consider rapid weight loss as beneficial, voluntary intoxication with T4 preparations is a growing cause for thyrotoxicosis. However, the long-lasting effects of transient thyrotoxicosis are poorly understood. Here we examined metabolic, thermoregulatory, and cardiovascular function upon induction and recovery from a 2-week thyrotoxicosis in male C57BL/6J mice. Our results showed that T4 treatment caused tachycardia, decreased hepatic glycogen stores, and higher body temperature as expected; however, we did not observe an increase in brown fat thermogenesis or decreased tail heat loss, suggesting that these tissues do not contribute to the hyperthermia induced by thyroid hormone. Most interestingly, when the T4 treatment was ended, a pronounced bradycardia was observed in the animals, which was likely caused by a rapid decline of T3 even below baseline levels. On the molecular level, this was accompanied by an overexpression of cardiac phospholamban and Serca2a mRNA, supporting the hypothesis that the heart depends more on T3 than T4. Our findings therefore demonstrate that a transient thyrotoxicosis can have pathological effects that even persist beyond the recovery of serum T4 levels, and in particular the observed bradycardia could be of clinical relevance when treating hyperthyroid patients.

  16. Thermal Diffusivity Measurements in Edible Oils using Transient Thermal Lens

    Science.gov (United States)

    Valdez, R. Carbajal.; Pérez, J. L. Jiménez.; Cruz-Orea, A.; Martín-Martínez, E. San.

    2006-11-01

    Time resolved thermal lens (TL) spectrometry is applied to the study of the thermal diffusivity of edible oils such as olive, and refined and thermally treated avocado oils. A two laser mismatched-mode experimental configuration was used, with a He Ne laser as a probe beam and an Ar+ laser as the excitation one. The characteristic time constant of the transient thermal lens was obtained by fitting the experimental data to the theoretical expression for a transient thermal lens. The results showed that virgin olive oil has a higher thermal diffusivity than for refined and thermally treated avocado oils. This measured thermal property may contribute to a better understanding of the quality of edible oils, which is very important in the food industry. The thermal diffusivity results for virgin olive oil, obtained from this technique, agree with those reported in the literature.

  17. Computational simulation of two-dimensional transient natural convection in volumetrically heated square enclosure

    International Nuclear Information System (INIS)

    Vieira, Camila Braga; Jian Su

    2010-01-01

    Natural convection is a physical phenomenon that has been investigated in nuclear engineering so as to provide information about heat transfer in severe accident conditions involving nuclear reactors. This research reported transient natural convection of fluids with uniformly distributed volumetrically heat generation in square cavity with isothermal side walls and adiabatic top/bottom walls. Two Prandtl numbers were considered, 0:0321 and 0:71. Direct numerical simulations were applied in order to obtain results about the velocities of the fluid in directions x and y. These results were used in Fast Fourier Transform, which showed the periodic, quasi-chaotic and chaotic behavior of transient laminar flow. (author)

  18. Parametric investigation on transient boiling heat transfer of metal rod cooled rapidly in water pool

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chi Young [Department of Fire Protection Engineering, Pukyong National University, 45, Yongso-ro, Nam-gu, Busan 48513 (Korea, Republic of); Kim, Sunwoo, E-mail: swkim@alaska.edu [Mechanical Engineering Department, University of Alaska Fairbanks, P. O. Box 755905, Fairbanks, AK 99775-5905 (United States)

    2017-03-15

    Highlights: • Effects of liquid subcooling, surface coating, material property, and surface oxidation are examined. • Liquid subcooling affects remarkably the quenching phenomena. • Cr-coated surfaces for ATF might extend the quenching duration. • Solids with low heat capacity shorten the quenching duration. • Surface oxidation can affect strongly the film boiling heat transfer and MFB point. - Abstract: In this work, the effects of liquid subcooling, surface coating, material property, and surface oxidation on transient pool boiling heat transfer were investigated experimentally using the vertical metal rod and quenching method. The change in rod temperature was measured with time during quenching, and the visualization of boiling around the test specimen was performed using the high-speed video camera. As the test materials, the zircaloy (Zry), stainless steel (SS), niobium (Nb), and copper (Cu) were tested. In addition, the chromium-coated niobium (Cr-Nb) and chromium-coated stainless steel (Cr-SS) were prepared for accident tolerant fuel (ATF) application. Low liquid subcooling and Cr-coating shifted the quenching curve to the right, which indicates a prolongation of quenching duration. On the other hand, the material with small heat capacity and surface oxidation caused the quenching curve to move to the left. To examine the influence of the material property and surface oxidation on the film boiling heat transfer performance and minimum film boiling (MFB) point in more detail, the wall temperature and heat flux were calculated from the present transient temperature profile using the inverse heat transfer analysis, and then the curves of wall temperature and heat flux in the film boiling regime were obtained. In the present experimental conditions, the effect of material property on the film boiling heat transfer performance and MFB point seemed to be minor. On the other hand, based on the experimental results of the Cu test specimen, the surface

  19. Clustered and transient earthquake sequences in mid-continents

    Science.gov (United States)

    Liu, M.; Stein, S. A.; Wang, H.; Luo, G.

    2012-12-01

    Earthquakes result from sudden release of strain energy on faults. On plate boundary faults, strain energy is constantly accumulating from steady and relatively rapid relative plate motion, so large earthquakes continue to occur so long as motion continues on the boundary. In contrast, such steady accumulation of stain energy does not occur on faults in mid-continents, because the far-field tectonic loading is not steadily distributed between faults, and because stress perturbations from complex fault interactions and other stress triggers can be significant relative to the slow tectonic stressing. Consequently, mid-continental earthquakes are often temporally clustered and transient, and spatially migrating. This behavior is well illustrated by large earthquakes in North China in the past two millennia, during which no single large earthquakes repeated on the same fault segments, but moment release between large fault systems was complementary. Slow tectonic loading in mid-continents also causes long aftershock sequences. We show that the recent small earthquakes in the Tangshan region of North China are aftershocks of the 1976 Tangshan earthquake (M 7.5), rather than indicators of a new phase of seismic activity in North China, as many fear. Understanding the transient behavior of mid-continental earthquakes has important implications for assessing earthquake hazards. The sequence of large earthquakes in the New Madrid Seismic Zone (NMSZ) in central US, which includes a cluster of M~7 events in 1811-1812 and perhaps a few similar ones in the past millennium, is likely a transient process, releasing previously accumulated elastic strain on recently activated faults. If so, this earthquake sequence will eventually end. Using simple analysis and numerical modeling, we show that the large NMSZ earthquakes may be ending now or in the near future.

  20. Semi-Markov models for interval censored transient cognitive states with back transitions and a competing risk.

    Science.gov (United States)

    Wei, Shaoceng; Kryscio, Richard J

    2016-12-01

    Continuous-time multi-state stochastic processes are useful for modeling the flow of subjects from intact cognition to dementia with mild cognitive impairment and global impairment as intervening transient cognitive states and death as a competing risk. Each subject's cognition is assessed periodically resulting in interval censoring for the cognitive states while death without dementia is not interval censored. Since back transitions among the transient states are possible, Markov chains are often applied to this type of panel data. In this manuscript, we apply a semi-Markov process in which we assume that the waiting times are Weibull distributed except for transitions from the baseline state, which are exponentially distributed and in which we assume no additional changes in cognition occur between two assessments. We implement a quasi-Monte Carlo (QMC) method to calculate the higher order integration needed for likelihood estimation. We apply our model to a real dataset, the Nun Study, a cohort of 461 participants. © The Author(s) 2014.

  1. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Transient dynamics of allophycocyanin trimers and monomers are observed by using the pump-probe, transient absorption technique. The origin of spectral components of the transient absorption spectra is discussed in terms of both kinetics and spectroscopy. We find that the energy gap between the ground and excited ...

  2. The joy of transient chaos

    Energy Technology Data Exchange (ETDEWEB)

    Tél, Tamás [Institute for Theoretical Physics, Eötvös University, and MTA-ELTE Theoretical Physics Research Group, Pázmány P. s. 1/A, Budapest H-1117 (Hungary)

    2015-09-15

    We intend to show that transient chaos is a very appealing, but still not widely appreciated, subfield of nonlinear dynamics. Besides flashing its basic properties and giving a brief overview of the many applications, a few recent transient-chaos-related subjects are introduced in some detail. These include the dynamics of decision making, dispersion, and sedimentation of volcanic ash, doubly transient chaos of undriven autonomous mechanical systems, and a dynamical systems approach to energy absorption or explosion.

  3. The joy of transient chaos.

    Science.gov (United States)

    Tél, Tamás

    2015-09-01

    We intend to show that transient chaos is a very appealing, but still not widely appreciated, subfield of nonlinear dynamics. Besides flashing its basic properties and giving a brief overview of the many applications, a few recent transient-chaos-related subjects are introduced in some detail. These include the dynamics of decision making, dispersion, and sedimentation of volcanic ash, doubly transient chaos of undriven autonomous mechanical systems, and a dynamical systems approach to energy absorption or explosion.

  4. The ZTF Bright Transient Survey

    Science.gov (United States)

    Fremling, C.; Sharma, Y.; Kulkarni, S. R.; Miller, A. A.; Taggart, K.; Perley, D. A.; Gooba, A.

    2018-06-01

    As a supplement to the Zwicky Transient Facility (ZTF; ATel #11266) public alerts (ATel #11685) we plan to report (following ATel #11615) bright probable supernovae identified in the raw alert stream from the ZTF Northern Sky Survey ("Celestial Cinematography"; see Bellm & Kulkarni, 2017, Nature Astronomy 1, 71) to the Transient Name Server (https://wis-tns.weizmann.ac.il) on a daily basis; the ZTF Bright Transient Survey (BTS; see Kulkarni et al., 2018; arXiv:1710.04223).

  5. Effect of helium pressure on the response of unirradiated UO2 subjected to thermal transients

    International Nuclear Information System (INIS)

    Fenske, G.R.; Chapello, P.M.; Emerson, J.E.; Poeppel, R.B.

    1983-01-01

    The effect of helium pressure on the transient response of unirradiated depleted UO 2 subjected to simulated hypothetical loss-of-flow accidents in a gas-cooled fast reactor was examined by use of the direct electrical heating technique. Transient tests were performed at pressures ranging from 7 to 10 X 10 5 Pa(7 to 10 atm) to 7 to 8 MPa (70 to 80 atm) on radially restrained and unrestrained fuel segments. The average heating rates ranged from about17 to 240 J/g x s. The results indicate that while the mechanical integrity of the fuel segment was independent of the test pressure, the rapid ejection of molten fuel from pellet interfaces of unrestrained fuel, observed at the lower pressures, was delayed or suppressed at the higher pressures

  6. Explosive and radio-selected Transients: Transient Astronomy with ...

    Indian Academy of Sciences (India)

    40

    sitive measurements will lead to very accurate mass loss estimation in these supernovae. .... transients are powerful probes of intervening media owing to dispersion ...... A., & Chandra, P. 2011, Nature Communications,. 2, 175. Chakraborti, S.

  7. Electromagnetic transients in power cables

    CERN Document Server

    da Silva, Filipe Faria

    2013-01-01

    From the more basic concepts to the most advanced ones where long and laborious simulation models are required, Electromagnetic Transients in Power Cables provides a thorough insight into the study of electromagnetic transients and underground power cables. Explanations and demonstrations of different electromagnetic transient phenomena are provided, from simple lumped-parameter circuits to complex cable-based high voltage networks, as well as instructions on how to model the cables.Supported throughout by illustrations, circuit diagrams and simulation results, each chapter contains exercises,

  8. Product sampling during transient continuous countercurrent hydrolysis of canola oil and development of a kinetic model

    KAUST Repository

    Wang, Weicheng; Natelson, Robert H.; Stikeleather, Larry F.; Roberts, William L.

    2013-01-01

    A chemical kinetic model has been developed for the transient stage of the continuous countercurrent hydrolysis of triglycerides to free fatty acids and glycerol. Departure functions and group contribution methods were applied to determine

  9. Enhanced Severe Transient Analysis for Prevention Technical Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    Gougar, Hans [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    This document outlines the development of a high fidelity, best estimate nuclear power plant severe transient simulation capability that will complement or enhance the integral system codes historically used for licensing and analysis of severe accidents. As with other tools in the Risk Informed Safety Margin Characterization (RISMC) Toolkit, the ultimate user of Enhanced Severe Transient Analysis and Prevention (ESTAP) capability is the plant decision-maker; the deliverable to that customer is a modern, simulation-based safety analysis capability, applicable to a much broader class of safety issues than is traditional Light Water Reactor (LWR) licensing analysis. Currently, the RISMC pathway’s major emphasis is placed on developing RELAP-7, a next-generation safety analysis code, and on showing how to use RELAP-7 to analyze margin from a modern point of view: that is, by characterizing margin in terms of the probabilistic spectra of the “loads” applied to systems, structures, and components (SSCs), and the “capacity” of those SSCs to resist those loads without failing. The first objective of the ESTAP task, and the focus of one task of this effort, is to augment RELAP-7 analyses with user-selected multi-dimensional, multi-phase models of specific plant components to simulate complex phenomena that may lead to, or exacerbate, severe transients and core damage. Such phenomena include: coolant crossflow between PWR assemblies during a severe reactivity transient, stratified single or two-phase coolant flow in primary coolant piping, inhomogeneous mixing of emergency coolant water or boric acid with hot primary coolant, and water hammer. These are well-documented phenomena associated with plant transients but that are generally not captured in system codes. They are, however, generally limited to specific components, structures, and operating conditions. The second ESTAP task is to similarly augment a severe (post-core damage) accident integral analyses code

  10. Spectroscopic classification of transients

    DEFF Research Database (Denmark)

    Stritzinger, M. D.; Fraser, M.; Hummelmose, N. N.

    2017-01-01

    We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017.......We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017....

  11. Transient Bone Marrow Edema Syndrome (Case Report

    Directory of Open Access Journals (Sweden)

    Nilnur Konuralp

    2003-09-01

    Full Text Available Transient bone marrow edema syndrome (BMES is accepted as a possible cause of acute disabling hip pain. This syndrome is defined as local osteoporosis in hip in radiographies, BME in MRI which can be rarely seen and has a self-limiting course. Although the disease generally has a self-limiting course, surgical treatment by early core decompression of the femoral head has proven effective in rapidly relieving the symptoms. Although BMES is relatively rare and probably underdiagnosed when compared to nontraumatic osteonecrosis, both conditions are associated with known osteonecrosis risk factors in middle aged men and especially with late (thirdhad trimester pregnancy in women. We have reported three cases with BMES that had different etiology and followed up presented the differential diagnosis to nontraumatic avascular osteonecrosis. These three cases were treated in early stage very succesfully.

  12. Transient thermal-hydraulic characteristics analysis software for PWR nuclear power systems

    International Nuclear Information System (INIS)

    Wu Yingwei; Zhuang Chengjun; Su Guanghui; Qiu Suizheng

    2010-01-01

    A point reactor neutron kinetics model, a two-phase drift-flow U-tube steam generator model, an advanced non-equilibrium three regions pressurizer model, and a passive emergency core decay heat-removed system model are adopted in the paper to develop the computerized analysis code for PWR transient thermal-hydraulic characteristics, by Compaq Visual Fortran 6.0 language. Visual input, real-time processing and dynamic visualization output are achieved by Microsoft Visual Studio. NET language. The reliability verification of the soft has been conducted by RELAP 5, and the verification results show that the software is with high calculation precision, high calculation speed, modern interface, luxuriant functions and strong operability. The software was applied to calculate the transient accident conditions for QSNP, and the analysis results are significant to the practical engineering applications. (authors)

  13. An Introduction to Transient Engine Applications Using the Numerical Propulsion System Simulation (NPSS) and MATLAB

    Science.gov (United States)

    Chin, Jeffrey C.; Csank, Jeffrey T.; Haller, William J.; Seidel, Jonathan A.

    2016-01-01

    This document outlines methodologies designed to improve the interface between the Numerical Propulsion System Simulation framework and various control and dynamic analyses developed in the Matlab and Simulink environment. Although NPSS is most commonly used for steady-state modeling, this paper is intended to supplement the relatively sparse documentation on it's transient analysis functionality. Matlab has become an extremely popular engineering environment, and better methodologies are necessary to develop tools that leverage the benefits of these disparate frameworks. Transient analysis is not a new feature of the Numerical Propulsion System Simulation (NPSS), but transient considerations are becoming more pertinent as multidisciplinary trade-offs begin to play a larger role in advanced engine designs. This paper serves to supplement the relatively sparse documentation on transient modeling and cover the budding convergence between NPSS and Matlab based modeling toolsets. The following sections explore various design patterns to rapidly develop transient models. Each approach starts with a base model built with NPSS, and assumes the reader already has a basic understanding of how to construct a steady-state model. The second half of the paper focuses on further enhancements required to subsequently interface NPSS with Matlab codes. The first method being the simplest and most straightforward but performance constrained, and the last being the most abstract. These methods aren't mutually exclusive and the specific implementation details could vary greatly based on the designer's discretion. Basic recommendations are provided to organize model logic in a format most easily amenable to integration with existing Matlab control toolsets.

  14. Transient or permanent fisheye views

    DEFF Research Database (Denmark)

    Jakobsen, Mikkel Rønne; Hornbæk, Kasper

    2012-01-01

    Transient use of information visualization may support specific tasks without permanently changing the user interface. Transient visualizations provide immediate and transient use of information visualization close to and in the context of the user’s focus of attention. Little is known, however......, about the benefits and limitations of transient visualizations. We describe an experiment that compares the usability of a fisheye view that participants could call up temporarily, a permanent fisheye view, and a linear view: all interfaces gave access to source code in the editor of a widespread...... programming environment. Fourteen participants performed varied tasks involving navigation and understanding of source code. Participants used the three interfaces for between four and six hours in all. Time and accuracy measures were inconclusive, but subjective data showed a preference for the permanent...

  15. Application of potential relaxation transient measurements to corrosion of steel in concrete

    International Nuclear Information System (INIS)

    Benjamin, S.E.; Skyes, J.M.

    1993-01-01

    Corrosion of steel in concrete is an electrochemical process that involves the process occurring at the interface and also in the bulk diffusion of species. This paper present studies on corrosion of Swedish Iron in concrete utilizing potential relaxation transients. This rapid new D.C. technique (developed at Oxford University, U.K.) analyzes the decay in terms of different resistor (R) - capacitor(c) combinations, thus identifying the individual processes as their time constants(tau). The resistance of the concrete is also separated. The merits and demerits of the technique are discussed. (author)

  16. iPTF SEARCH FOR AN OPTICAL COUNTERPART TO GRAVITATIONAL-WAVE TRANSIENT GW150914

    Energy Technology Data Exchange (ETDEWEB)

    Kasliwal, M. M.; Cao, Y.; Barlow, T.; Bellm, E.; Cook, D.; Duggan, G. E.; Kulkarni, S. R.; Lunnan, R. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Cenko, S. B.; Singer, L. P. [Astrophysics Science Division, NASA Goddard Space Flight Center, Code 661, Greenbelt, MD 20771 (United States); Corsi, A.; Palliyaguru, N. [Texas Tech University, Physics Department, Lubbock, TX 79409-1051 (United States); Bhalerao, V. [Inter-University Centre for Astronomy and Astrophysics (IUCAA), Post Bag 4, Ganeshkhind, Pune 411007 (India); Ferretti, R. [The Oskar Klein Centre, Department of Physics, Stockholm University, SE-106 91 Stockholm (Sweden); Frail, D. A. [National Radio Astronomy Observatory, Socorro, NM (United States); Horesh, A.; Manulis, I. [Department of Particle Physics and Astrophysics, Weizmann Institute of Science, 76100 Rehovot (Israel); Kendrick, R. [Lockheed Martin Space Systems Company, Palo Alto, CA (United States); Laher, R. [Spitzer Science Center, California Institute of Technology, M/S 314-6, Pasadena, CA 91125 (United States); Masci, F. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); and others

    2016-06-20

    The intermediate Palomar Transient Factory (iPTF) autonomously responded to and promptly tiled the error region of the first gravitational-wave event GW150914 to search for an optical counterpart. Only a small fraction of the total localized region was immediately visible in the northern night sky, due both to Sun-angle and elevation constraints. Here, we report on the transient candidates identified and rapid follow-up undertaken to determine the nature of each candidate. Even in the small area imaged of 126 deg{sup 2}, after extensive filtering, eight candidates were deemed worthy of additional follow-up. Within two hours, all eight were spectroscopically classified by the Keck II telescope. Curiously, even though such events are rare, one of our candidates was a superluminous supernova. We obtained radio data with the Jansky Very Large Array and X-ray follow-up with the Swift satellite for this transient. None of our candidates appear to be associated with the gravitational-wave trigger, which is unsurprising given that GW150914 came from the merger of two stellar-mass black holes. This end-to-end discovery and follow-up campaign bodes well for future searches in this post-detection era of gravitational waves.

  17. Transient transformation meets gene function discovery: the strawberry fruit case

    Directory of Open Access Journals (Sweden)

    Michela eGuidarelli

    2015-06-01

    Full Text Available Beside the well known nutritional and health benefits, strawberry (Fragaria X ananassa crop draws increasing attention as plant model system for the Rosaceae family, due to the short generation time, the rapid in vitro regeneration, and to the availability of the genome sequence of F. X ananassa and of the closely related F. vesca species. In the last years, the use of high-throughput sequence technologies provided large amounts of molecular information on the genes possibly related to several biological processes of this crop. Nevertheless, the function of most genes or gene products is still poorly understood and needs investigation. Transient transformation technology provides a powerful tool to study gene function in vivo, avoiding difficult drawbacks that typically affect the stable transformation protocols, such as transformation efficiency, transformants selection and regeneration. In this review we provide an overview of the use of transient expression in the investigation of the function of genes important for strawberry fruit development, defence and nutritional properties. The technical aspects related to an efficient use of this technique are described, and the possible impact and application in strawberry crop improvement are discussed.

  18. Current and anticipated use of thermal-hydraulic codes for BWR transient and accident analyses in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Kenji; Ebata, Shigeo [Toshiba Corp., Yokohama (Japan)

    1997-07-01

    This paper summarizes the current and anticipated use of the thermal-hydraulic and neutronic codes for the BWR transient and accident analyses in Japan. The codes may be categorized into the licensing codes and the best estimate codes for the BWR transient and accident analyses. Most of the licensing codes have been originally developed by General Electric. Some codes have been updated based on the technical knowledge obtained in the thermal hydraulic study in Japan, and according to the BWR design changes. The best estimates codes have been used to support the licensing calculations and to obtain the phenomenological understanding of the thermal hydraulic phenomena during a BWR transient or accident. The best estimate codes can be also applied to a design study for a next generation BWR to which the current licensing model may not be directly applied. In order to rationalize the margin included in the current BWR design and develop a next generation reactor with appropriate design margin, it will be required to improve the accuracy of the thermal-hydraulic and neutronic model. In addition, regarding the current best estimate codes, the improvement in the user interface and the numerics will be needed.

  19. TASS code topical report. V.2 TASS code validation report for the non-LOCA transient analysis of the CE and Westinghouse type plants

    International Nuclear Information System (INIS)

    Sim, Suk K.; Chang, W. P.; Kim, K. D.; Lee, S. J.; Kim, H. C.; Yoon, H. Y.

    1997-02-01

    The development of TASS 1.0 code has been completed and validated its capability in applying for the licensing transient analyses of the CE and Westinghouse type operating reactors as well as the PWR plants under construction in Korea. The validation of the TASS 1.0 code has been achieved through the comparison calculations of the FSAR transients, loss of AC power transient plant data, load rejection and startup test data for the reference plants as well as the BETHSY loop steam generator tube rupture test data. TASS 1.0 calculation agrees well with the best FSAR transient and shows its capability in simulating plant transient analyses. (author). 12 refs., 32 tabs., 132 figs

  20. Rapid Modulation of Aromatase Activity in the Vertebrate Brain

    Directory of Open Access Journals (Sweden)

    Thierry D. Charlier

    2013-01-01

    Full Text Available Numerous steroid hormones, including 17β-estradiol (E2, activate rapid and transient cellular, physiological, and behavioral changes in addition to their well-described genomic effects. Aromatase is the key-limiting enzyme in the production of estrogens, and the rapid modulation of this enzymatic activity could produce rapid changes in local E2 concentrations. The mechanisms that might mediate such rapid enzymatic changes are not fully understood but are currently under intense scrutiny. Recent studies in our laboratory indicate that brain aromatase activity is rapidly inhibited by an increase in intracellular calcium concentration resulting from potassium-induced depolarization or from the activation of glutamatergic receptors. Phosphorylating conditions also reduce aromatase activity within minutes, and this inhibition is blocked by the addition of multiple protein kinase inhibitors. This rapid modulation of aromatase activity by phosphorylating conditions is a general mechanism observed in different cell types and tissues derived from a variety of species, including human aromatase expressed in various cell lines. Phosphorylation processes affect aromatase itself and do not involve changes in aromatase protein concentration. The control of aromatase activity by multiple kinases suggests that several amino acids must be concomitantly phosphorylated to modify enzymatic activity but site-directed mutagenesis of several amino acids alone or in combination has not to date revealed the identity of the targeted residue(s. Altogether, the phosphorylation processes affecting aromatase activity provide a new general mechanism by which the concentration of estrogens can be rapidly altered in the brain.

  1. Method of construction of transient from a cycle of neuronal recurrence equation

    International Nuclear Information System (INIS)

    Ndoundam, R.; Tchuente, M.

    2005-11-01

    We study the sequences generated by neuronal recurrence equations of the form x(n) = 1[Σ j k =1 a j x(n - j) - θ], where k is the size of memory (k represents the number of previous states x(n - 1), x(n - 2), ...,x(n - k) which intervene in the calculation of x(n)). We are interested in the number of steps (transient length) from an initial configuration to the cycle. We propose a method of construction of transient from a cycle generated by neuronal recurrence equation. We apply this method to build a neuronal recurrence equation with inhibitory memory of size (s+1)6m, whose dynamics contains an evolution of transient length (s + 1) x (5m + 2 + lcm(p 0 , p 1 , ..., p 1 , 3m - 1)) and a cycle of length (s + 1) x lcm(p 0 , p 1 , ..., p s-1 , 2m + 1) where lcm denotes the least common multiple, and p 0 , p 1 , ..., p s-1 are prime numbers lying between 2m and 3m. (author)

  2. THE PHOTOMETRIC AND SPECTRAL EVOLUTION OF THE 2008 LUMINOUS OPTICAL TRANSIENT IN NGC 300

    International Nuclear Information System (INIS)

    Humphreys, Roberta M.; Davidson, Kris; Bond, Howard E.; Bedin, Luigi R.; Bonanos, Alceste Z.; Berto Monard, L. A. G.; Prieto, José L.; Walter, Frederick M.

    2011-01-01

    The 2008 optical transient in NGC 300 is one of a growing class of intermediate-luminosity transients that brighten several orders of magnitude from a previously optically obscured state. The origin of their eruptions is not understood. Our multi-wavelength photometry and spectroscopy from maximum light to more than a year later provide a record of its post-eruption behavior. We describe its changing spectral energy distribution, the evolution of its absorption- and emission-line spectrum, the development of a bipolar outflow, and the rapid transition from a dense wind to an optically thin ionized wind. In addition to strong, narrow hydrogen lines, the F-type absorption-line spectrum of the transient is characterized by strong Ca II and [Ca II] emission. The very broad wings of the Ca II triplet and the asymmetric [Ca II] emission lines are due to strong Thomson scattering in the expanding ejecta. Post-maximum, the hydrogen and Ca II lines developed double-peaked emission profiles that we attribute to a bipolar outflow. Between approximately 60 and 100 days after maximum, the F-type absorption spectrum, formed in its dense wind, weakened and the wind became transparent to ionizing radiation. We discuss the probable evolutionary state of the transient and similar objects such as SN 2008S and conclude that they were most likely post-red supergiants or post-asymptotic giant branch stars on a blue loop to warmer temperatures when the eruption occurred. These objects are not luminous blue variables.

  3. Quantification of metabolically active transient storage (MATS) in two reaches with contrasting transient storage and ecosystem respiration

    Science.gov (United States)

    Alba Argerich; Roy Haggerty; Eugènia Martí; Francesc Sabater; Jay. Zarnetske

    2011-01-01

    Water transient storage zones are hotspots for metabolic activity in streams although the contribution of different types of transient storage zones to the whole�]reach metabolic activity is difficult to quantify. In this study we present a method to measure the fraction of the transient storage that is metabolically active (MATS) in two consecutive reaches...

  4. Global thunderstorm activity estimation based on number of transients in ELF-band

    Science.gov (United States)

    Ondraskova, Adriena; Sevcik, Sebastian

    2017-04-01

    Schumann resonances (SR) are resonant electromagnetic oscillations in extremely low frequency band (ELF, 3 Hz - 3 kHz), which arise in the Earth-ionosphere cavity due to lightning activity in planetary range. The time records in the ELF-band consist of background signals and ELF transients/Q-bursts superimposed on the background exceeding it by a factor of 5 - 10. The former are produced by the common worldwide thunderstorm activity (100 - 150 events per second), the latter origin from individual intense distant lightning discharges (100 - 120 powerful strokes per hour). A Q-burst is produced by a combination of direct and antipodal pulses and the decisive factor for its shape follows from the source-to-observer distance. Diurnal/seasonal variations of global thunderstorm activity can be deduced from spectral amplitudes of SR modes. Here we focus on diurnal/seasonal variations of the number of ELF-transients assuming that it is another way of lightning activity estimation. To search for transients, our own code was applied to the SR vertical electric component measured in October 2004 - October 2008 at the Astronomical and Geophysical Observatory of FMPI CU, Slovakia. Criteria for the identification of the burst are chosen on the basis of the transient amplitudes and their morphological features. Monthly mean daily variations in number of transients showed that African focus dominates at 14 - 16 h UT and it is more active in comparison with Asian source, which dominates at 5 - 8 h UT in dependence on winter or summer month. American source had surprisingly slight response. Meteorological observations in South America aiming to determine lightning hotspots on the Earth indicate that flash rate in this region is greatest during nocturnal 0 h - 3 h local standard time. This fact may be interpreted that Asian and South American sources contribute together in the same UT. Cumulative spectral amplitude of the first three SR modes compared with number of ELF-transients in

  5. Pressure transients across HEPA filters

    International Nuclear Information System (INIS)

    Gregory, W.; Reynolds, G.; Ricketts, C.; Smith, P.R.

    1977-01-01

    Nuclear fuel cycle facilities require ventilation for health and safety reasons. High efficiency particulate air (HEPA) filters are located within ventilation systems to trap radioactive dust released in reprocessing and fabrication operations. Pressure transients within the air cleaning systems may be such that the effectiveness of the filtration system is questioned under certain accident conditions. These pressure transients can result from both natural and man-caused phenomena: atmospheric pressure drop caused by a tornado or explosions and nuclear excursions initiate pressure pulses that could create undesirable conditions across HEPA filters. Tornado depressurization is a relatively slow transient as compared to pressure pulses that result from combustible hydrogen-air mixtures. Experimental investigation of these pressure transients across air cleaning equipment has been undertaken by Los Alamos Scientific Laboratory and New Mexico State University. An experimental apparatus has been constructed to impose pressure pulses across HEPA filters. The experimental equipment is described as well as preliminary results using variable pressurization rates. Two modes of filtration of an aerosol injected upstream of the filter is examined. A laser instrumentation for measuring the aerosol release, during the transient, is described

  6. Recent development of transient electronics

    Directory of Open Access Journals (Sweden)

    Huanyu Cheng

    2016-01-01

    Full Text Available Transient electronics are an emerging class of electronics with the unique characteristic to completely dissolve within a programmed period of time. Since no harmful byproducts are released, these electronics can be used in the human body as a diagnostic tool, for instance, or they can be used as environmentally friendly alternatives to existing electronics which disintegrate when exposed to water. Thus, the most crucial aspect of transient electronics is their ability to disintegrate in a practical manner and a review of the literature on this topic is essential for understanding the current capabilities of transient electronics and areas of future research. In the past, only partial dissolution of transient electronics was possible, however, total dissolution has been achieved with a recent discovery that silicon nanomembrane undergoes hydrolysis. The use of single- and multi-layered structures has also been explored as a way to extend the lifetime of the electronics. Analytical models have been developed to study the dissolution of various functional materials as well as the devices constructed from this set of functional materials and these models prove to be useful in the design of the transient electronics.

  7. Transient behaviour of deep underground salt caverns; Comportement transitoire des cavites salines profondes

    Energy Technology Data Exchange (ETDEWEB)

    Karimi-Jafari, M

    2007-11-15

    This work deals with the transient behaviour of deep underground salt caverns. It has been shown that a cavern is a complex system, in which there are mechanical, thermal, chemical and hydraulic evolutions. The importance of the transient evolutions, particularly the role of the 'reverse' creep in the interpretation of the tightness test in a salt cavern is revealed. Creep is characterized by a formulation of the behaviour law which presents the advantage, in a practical point of view, to only have a reduced number of parameters while accounting of the essential of what it is observed. The initiation of the rupture in the effective traction in a salt cavern rapidly pressurized is discussed. A model fitted to a very long term behaviour (after abandonment) is developed too. In this case too, a lot of phenomena, more or less coupled, occur, when the existing literature took only into account some phenomena. (O.M.)

  8. Impact of rapid condensations of large vapor spaces on natural circulation in integral systems

    International Nuclear Information System (INIS)

    Wang, Z.; Almenas, K.; DiMarzo, M.; Hsu, Y.Y.; Unal, C.

    1992-01-01

    In this study we demonstrated that the Interruption-Resumption flow mode (IRM) observed in the University of Maryland 2x4 loop is a unique and effective natural circulation cooling mode. The IRM flow mode consists of a series of large flow cycles which are initiated from a quiescent steady-state flow condition by periodic rapid condensation of large vapor spaces. The significance of this mass/energy transport mechanism is that it cannot be evaluated using the techniques developed for the commonly known density-driven natural circulation cooling mode. We also demonstrated that the rapid condensation mechanism essentially acts as a strong amplifier which will augment small perturbations and will activate several flow phenomena. The interplay of the phenomena involves a degree of randomness. This poses two important implications. First, the study of an isolated flow phenomenon is not sufficient for the understanding of the system-wide IRM fluid movement. Second, the duplication of reactor transients which involves randomness can be achieved only within certain bounds. The modeling of such transients by deterministic computer codes requires recognition of this physical reality. (orig.)

  9. Mechano-chemical signaling maintains the rapid movement of Dictyostelium cells

    International Nuclear Information System (INIS)

    Lombardi, M.L.; Knecht, D.A.; Lee, J.

    2008-01-01

    The survival of Dictyostelium cells depends on their ability to efficiently chemotax, either towards food or to form multicellular aggregates. Although the involvement of Ca 2+ signaling during chemotaxis is well known, it is not clear how this regulates cell movement. Previously, fish epithelial keratocytes have been shown to display transient increases in intracellular calcium ([Ca 2+ ] i ) that are mediated by stretch-activated calcium channels (SACs), which play a role in retraction of the cell body [J. Lee, A. Ishihara, G. Oxford, B. Johnson, and K. Jacobson, Regulation of cell movement is mediated by stretch-activated calcium channels. Nature, 1999. 400(6742): p. 382-6.]. To investigate the involvement of SACs in Dictyostelium movement we performed high resolution calcium imaging in wild-type (NC4A2) Dictyostelium cells to detect changes in [Ca 2+ ] i . We observed small, brief, Ca 2+ transients in randomly moving wild-type cells that were dependent on both intracellular and extracellular sources of calcium. Treatment of cells with the SAC blocker gadolinium (Gd 3+ ) inhibited transients and decreased cell speed, consistent with the involvement of SACs in regulating Dictyostelium motility. Additional support for SAC activity was given by the increase in frequency of Ca 2+ transients when Dictyostelium cells were moving on a more adhesive substratum or when they were mechanically stretched. We conclude that mechano-chemical signaling via SACs plays a major role in maintaining the rapid movement of Dictyostelium cells

  10. Cytoskeletal dynamics in interphase, mitosis and cytokinesis analysed through Agrobacterium-mediated transient transformation of tobacco BY-2 cells.

    Science.gov (United States)

    Buschmann, H; Green, P; Sambade, A; Doonan, J H; Lloyd, C W

    2011-04-01

    Transient transformation with Agrobacterium is a widespread tool allowing rapid expression analyses in plants. However, the available methods generate expression in interphase and do not allow the routine analysis of dividing cells. Here, we present a transient transformation method (termed 'TAMBY2') to enable cell biological studies in interphase and cell division. Agrobacterium-mediated transient gene expression in tobacco BY-2 was analysed by Western blotting and quantitative fluorescence microscopy. Time-lapse microscopy of cytoskeletal markers was employed to monitor cell division. Double-labelling in interphase and mitosis enabled localization studies. We found that the transient transformation efficiency was highest when BY-2/Agrobacterium co-cultivation was performed on solid medium. Transformants produced in this way divided at high frequency. We demonstrated the utility of the method by defining the behaviour of a previously uncharacterized microtubule motor, KinG, throughout the cell cycle. Our analyses demonstrated that TAMBY2 provides a flexible tool for the transient transformation of BY-2 with Agrobacterium. Fluorescence double-labelling showed that KinG localizes to microtubules and to F-actin. In interphase, KinG accumulates on microtubule lagging ends, suggesting a minus-end-directed function in vivo. Time-lapse studies of cell division showed that GFP-KinG strongly labels preprophase band and phragmoplast, but not the metaphase spindle. © 2010 The Authors. New Phytologist © 2010 New Phytologist Trust.

  11. Nuclear reactors transients identification and classification system; Sistema de identificacao e classificacao de transientes em reatores nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, Paulo Henrique

    2008-07-01

    This work describes the study and test of a system capable to identify and classify transients in thermo-hydraulic systems, using a neural network technique of the self-organizing maps (SOM) type, with the objective of implanting it on the new generations of nuclear reactors. The technique developed in this work consists on the use of multiple networks to do the classification and identification of the transient states, being each network a specialist at one respective transient of the system, that compete with each other using the quantization error, that is a measure given by this type of neural network. This technique showed very promising characteristics that allow the development of new functionalities in future projects. One of these characteristics consists on the potential of each network, besides responding what transient is in course, could give additional information about that transient. (author)

  12. The PARET code and the analysis of the SPERT I transients

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, William L [Argonne National Laboratory, Argonne (United States)

    1983-09-01

    The PARET code has been adapted for the testing of methods and models and for subsequent use in the analysis of transient behavior in research reactors. Comparisons with the experimental results from the SPERT-I transients are provided. The code has also been applied to the analysis of the IAEA 10 MW benchmark cores for protected and unprotected transients. The PARET code was originally developed for the analysis of the SPERT-III experiments for temperatures and pressures typical of power reactors. This code has now been modified to include a selection of flow instability, departure from nucleate boiling (DNB), single and two-phase heat transfer correlations, and a properties library considered more applicable to the low pressures, temperatures, and flow rates encountered in research reactors. The PARET code provides a coupled thermal, hydraulic, and point kinetics capability with continuous reactivity feedback, and an optional voiding model which estimates the voiding produced by subcooled boiling. The present version of the PARET code provides a convenient means of assessing the various models and correlations proposed for use in the analysis of research reactor behavior. For comparison with experiments the SPERT-I cores B-24/32, B-12/64, and D-12/25 were chosen. The B-24/32 core is similar in design to many plate type research reactors in current operation, and the D-12/25 core is of interest because the test included both nondestructive and destructive transients.

  13. The PARET code and the analysis of the SPERT I transients

    International Nuclear Information System (INIS)

    Woodruff, William L.

    1983-01-01

    The PARET code has been adapted for the testing of methods and models and for subsequent use in the analysis of transient behavior in research reactors. Comparisons with the experimental results from the SPERT-I transients are provided. The code has also been applied to the analysis of the IAEA 10 MW benchmark cores for protected and unprotected transients. The PARET code was originally developed for the analysis of the SPERT-III experiments for temperatures and pressures typical of power reactors. This code has now been modified to include a selection of flow instability, departure from nucleate boiling (DNB), single and two-phase heat transfer correlations, and a properties library considered more applicable to the low pressures, temperatures, and flow rates encountered in research reactors. The PARET code provides a coupled thermal, hydraulic, and point kinetics capability with continuous reactivity feedback, and an optional voiding model which estimates the voiding produced by subcooled boiling. The present version of the PARET code provides a convenient means of assessing the various models and correlations proposed for use in the analysis of research reactor behavior. For comparison with experiments the SPERT-I cores B-24/32, B-12/64, and D-12/25 were chosen. The B-24/32 core is similar in design to many plate type research reactors in current operation, and the D-12/25 core is of interest because the test included both nondestructive and destructive transients

  14. Transient Effects in Atmosphere and Ionosphere preceding the two 2015 M7.8 and M7.3 Earthquakes in Nepal

    Science.gov (United States)

    Ouzounov, D.; Pulinets, S. A.; Hernandez-Pajares, M.; Alberto Garcia Rigo, A. G.; Davidenko, D.; Hatzopoulos, N.; Kafatos, M.

    2015-12-01

    The recent M7.8 Nepal earthquake of April 25, 2015 was the largest recorded earthquake event to hit this nation since 1934. We prospectively and retrospectively analyzed the transient variations of three different physical parameters - outgoing earth radiation (OLR), GPS/TEC and the thermodynamic proprieties in the lower atmosphere. These changes characterize the state of the atmosphere and ionosphere several days before the onset of this earthquake. Our preliminary results show that in mid March 2015 a rapid increase of emitted infrared radiation was observed from the satellite data and an anomaly near the epicenter reached the maximum on April 21-22. The ongoing analysis of satellite radiation revealed another transient anomaly on May 3th, probably associated with the M7.3 of May 12, 2015. The analysis of air temperature form ground stations show similar patterns of rapid increases offset 1-2 days earlier to the satellite transient anomalies.The GPS/TEC data indicate an increase and variation in electron density reaching a maximum value during April 22-24. We found a strong negative TEC anomaly in the crest of EIA (Equatorial Ionospheric Anomaly) on April 21st and strong positive on April 24th, 2015. Our results show strong ionospheric effects not only in the changes of the EIA intensity but also within the latitudinal movements of the crests of EIA.

  15. Emittance growth from transient coherent synchrotron radiation

    International Nuclear Information System (INIS)

    Bohn, C.L.; Li, R.; Bisognano, J.J.

    1996-01-01

    If the energies of individual particles in a bunch change as the bunch traverses a bending system, even if it is achromatic, betatron oscillations can be excited. Consequently, the transverse emittance of the bunch will grow as it moves downstream. Short bunches may be particularly susceptible to emission of coherent synchrotron radiation which can act back on the particles to change their energies and trajectories. Because a bend spans a well-defined length and angle, the bunch-excited wakefield and its effect back on the bunch are inherently transient. We outline a recently developed theory of this effect and apply it to example bending systems

  16. A robust nonlinear stabilizer as a controller for improving transient stability in micro-grids.

    Science.gov (United States)

    Azimi, Seyed Mohammad; Afsharnia, Saeed

    2017-01-01

    This paper proposes a parametric-Lyapunov approach to the design of a stabilizer aimed at improving the transient stability of micro-grids (MGs). This strategy is applied to electronically-interfaced distributed resources (EI-DRs) operating with a unified control configuration applicable to all operational modes (i.e. grid-connected mode, islanded mode, and mode transitions). The proposed approach employs a simple structure compared with other nonlinear controllers, allowing ready implementation of the stabilizer. A new parametric-Lyapunov function is proposed rendering the proposed stabilizer more effective in damping system transition transients. The robustness of the proposed stabilizer is also verified based on both time-domain simulations and mathematical proofs, and an ultimate bound has been derived for the frequency transition transients. The proposed stabilizer operates by deploying solely local information and there are no needs for communication links. The deteriorating effects of the primary resource delays on the transient stability are also treated analytically. Finally, the effectiveness of the proposed stabilizer is evaluated through time-domain simulations and compared with the recently-developed stabilizers performed on a multi-resource MG. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Transient performance of EBR-II driver fuel

    International Nuclear Information System (INIS)

    Buzzell, J.A.; Hudman, G.D.; Porter, D.L.

    1981-01-01

    The first phases of qualification of the EBR-II driver fuel for repeated transient overpower operation have recently been completed. The accomplishments include prediction of the transient fuel and cladding performance through ex-core testing and fuel-element modeling studies, localized in-core power testing during steady-state operation, and whole-core multiple transient testing. The metallic driver fuel successfully survived 56 transients, spaced over a 45-day period, with power increases of approx. 160% at rates of approx. 1%/s with a 720-second hold at full power. The performance results obtained from both ex-core and n-core tests indicate that the fuel is capable of repeated transient operation

  18. Optical imaging of non-fluorescent nanodiamonds in live cells using transient absorption microscopy.

    Science.gov (United States)

    Chen, Tao; Lu, Feng; Streets, Aaron M; Fei, Peng; Quan, Junmin; Huang, Yanyi

    2013-06-07

    We directly observe non-fluorescent nanodiamonds in living cells using transient absorption microscopy. This label-free technology provides a novel modality to study the dynamic behavior of nanodiamonds inside the cells with intrinsic three-dimensional imaging capability. We apply this method to capture the cellular uptake of nanodiamonds under various conditions, confirming the endocytosis mechanism.

  19. A modal method for transient thermal analysis of CANDU fuel channel

    International Nuclear Information System (INIS)

    Park, J-W.; Muzumdar, A.J.

    1996-01-01

    The classical modal expansion technique has been applied to predict transient fuel and coolant temperatures under on-power conditions in a CANDU fuel channel. The temperature profile across the fuel pellet is assumed to be parabolic and fuel and coolant temperatures are expanded with Fourier series. The coefficient derivatives are written in state space form and solved by the Runge-Kutta method of fifth order. To validate the present model, the calculated fuel temperatures for several sample cases were compared with HOTSPOT-II, which employs a more rigorous finite-difference model. The agreement was found to be reasonable for the operational transients simulated. The advantage of the modal method is the fast computation speed for application to the real-time system such as the CANDU simulator which is being currently developed at the Institute for Advanced Engineering (IAE). (author)

  20. Geometrically Nonlinear Transient Response of Laminated Plates with Nonlinear Elastic Restraints

    Directory of Open Access Journals (Sweden)

    Shaochong Yang

    2017-01-01

    Full Text Available To investigate the dynamic behavior of laminated plates with nonlinear elastic restraints, a varied constraint force model and a systematic numerical procedure are presented in this work. Several kinds of typical relationships of force-displacement for spring are established to simulate the nonlinear elastic restraints. In addition, considering the restraining moments of flexible pads, the pads are modeled by translational and rotational springs. The displacement- dependent constraint forces are added to the right-hand side of equations of motion and treated as additional applied loads. These loads can be explicitly defined, via an independent set of nonlinear load functions. The time histories of transverse displacements at typical points of the laminated plate are obtained through the transient analysis. Numerical examples show that the present method can effectively treat the geometrically nonlinear transient response of plates with nonlinear elastic restraints.

  1. The OECD/NEA/NSC PBMR 400 MW coupled neutronics thermal hydraulics transient benchmark: transient results - 290

    International Nuclear Information System (INIS)

    Strydom, G.; Reitsma, F.; Ngeleka, P.T.; Ivanov, K.N.

    2010-01-01

    The PBMR is a High-Temperature Gas-cooled Reactor (HTGR) concept developed to be built in South Africa. The analysis tools used for core neutronic design and core safety analysis need to be verified and validated, and code-to-code comparisons are an essential part of the V and V plans. As part of this plan the PBMR 400 MWth design and a representative set of transient exercises are defined as an OECD benchmark. The scope of the benchmark is to establish a series of well defined multi-dimensional computational benchmark problems with a common given set of cross sections, to compare methods and tools in coupled neutronics and thermal hydraulics analysis with a specific focus on transient events. This paper describes the current status of the benchmark project and shows the results for the six transient exercises, consisting of three Loss of Cooling Accidents, two Control Rod Withdrawal transients, a power load-follow transient, and a Helium over-cooling Accident. The participants' results are compared using a statistical method and possible areas of future code improvement are identified. (authors)

  2. Irradiation creep transients in Ni-4 at.% Si

    International Nuclear Information System (INIS)

    Nagakawa, J.

    1983-01-01

    In the course of irradiation creep experiments on Ni-4 at.% Si alloy, two types of creep transients were observed on the termination of irradiation. The short term transient was completed within one minute while the long term transient persisted for nearly ten hours. A change in the temperature distribution was excluded from the possible causes, partly because the stress dependence of the observed transient strains was not linear, and partly because the strain increase expected from the temperature change was much smaller than the observed value. Transient behavior of point defects was examined in conjunction with the climb-glide mechanism and the steady-state irradiation creep data. Calculated creep transient due to excess vacancy flux to dislocations was in good agreement with the observed short term transient. The long term transient appears to be a result of dislocation microstructure change. The present results suggest an enhanced irradiation creep under cyclic irradiation conditions which will be encountered in the early generations of fusion reactors. (orig.)

  3. Wide Field Radio Transient Surveys

    Science.gov (United States)

    Bower, Geoffrey

    2011-04-01

    The time domain of the radio wavelength sky has been only sparsely explored. Nevertheless, serendipitous discovery and results from limited surveys indicate that there is much to be found on timescales from nanoseconds to years and at wavelengths from meters to millimeters. These observations have revealed unexpected phenomena such as rotating radio transients and coherent pulses from brown dwarfs. Additionally, archival studies have revealed an unknown class of radio transients without radio, optical, or high-energy hosts. The new generation of centimeter-wave radio telescopes such as the Allen Telescope Array (ATA) will exploit wide fields of view and flexible digital signal processing to systematically explore radio transient parameter space, as well as lay the scientific and technical foundation for the Square Kilometer Array. Known unknowns that will be the target of future transient surveys include orphan gamma-ray burst afterglows, radio supernovae, tidally-disrupted stars, flare stars, and magnetars. While probing the variable sky, these surveys will also provide unprecedented information on the static radio sky. I will present results from three large ATA surveys (the Fly's Eye survey, the ATA Twenty CM Survey (ATATS), and the Pi GHz Survey (PiGSS)) and several small ATA transient searches. Finally, I will discuss the landscape and opportunities for future instruments at centimeter wavelengths.

  4. Transient multivariable sensor evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Vilim, Richard B.; Heifetz, Alexander

    2017-02-21

    A method and system for performing transient multivariable sensor evaluation. The method and system includes a computer system for identifying a model form, providing training measurement data, generating a basis vector, monitoring system data from sensor, loading the system data in a non-transient memory, performing an estimation to provide desired data and comparing the system data to the desired data and outputting an alarm for a defective sensor.

  5. Transient analysis for resolving safety issues

    International Nuclear Information System (INIS)

    Chao, J.; Layman, W.

    1987-01-01

    The Nuclear Safety Analysis Center (NSAC) has a Generic Safety Analysis Program to help resolve high priority generic safety issues. This paper describes several high priority safety issues considered at NSAC and how they were resolved by transient analysis using thermal hydraulics and neutronics codes. These issues are pressurized thermal shock (PTS), anticipated transients without scram (ATWS), steam generator tube rupture (SGTR), and reactivity transients in light of the Chernobyl accident

  6. A High Temperature Experimental Characterization Procedure for Oxide-Based Thermoelectric Generator Modules under Transient Conditions

    DEFF Research Database (Denmark)

    Man, Elena Anamaria; Schaltz, Erik; Rosendahl, Lasse

    2015-01-01

    Characterization methods for thermoelectric generator (TEG) modules play an important role in studying their behavior and in enhancing the performance and simulation of TEG systems also. The purpose of this study is to analyze the behavior in transient and steady-state of the temperature applied...

  7. Positron deep-level transient spectroscopy in semi-insulating-GaAs using the positron velocity transient method

    International Nuclear Information System (INIS)

    Tsia, M.; Fung, S.; Beling, C.D.

    2001-01-01

    Recently a new semiconductor defect spectroscopy, namely positron deep level transient spectroscopy (PDLTS) has been proposed that combines the energy selectivity of deep level transient spectroscopy with the structural sensitivity of positron annihilation spectroscopy. This paper focuses on one variant of PDLTS, namely positron velocity PDLTS, which has no sensitivity towards vacancy defects but nevertheless is useful in studying deep levels in semi-insulators. In the present study the electric field within the depletion region of semi-insulating GaAs is monitored through the measurement of the small Doppler shift in the annihilation radiation that comes from this region as a result of positron drift. The drift is the result of an increasing electric field produced by space charge building up from ionizing deep level defects. Doppler shift transients are measured between 50-300 K. The EL2 level emission transients are clearly seen at temperatures around 300 K that yield E C -0.78±0.08eV for the energy of EL2. The EL2 electron capture rate is found to have an activation energy of 0.61±0.08eV which most probably arises from freeze out of conduction electrons. We find the surprising result that emission and capture transients can be seen at temperatures below 200 K. Possible reasons for these transients are discussed. (orig.)

  8. Pressure transients in pipeline systems

    DEFF Research Database (Denmark)

    Voigt, Kristian

    1998-01-01

    This text is to give an overview of the necessary background to do investigation of pressure transients via simulations. It will describe briefly the Method of Characteristics which is the defacto standard for simulating pressure transients. Much of the text has been adopted from the book Pressur...

  9. Compositional Abstraction of PEPA Models for Transient Analysis

    DEFF Research Database (Denmark)

    Smith, Michael James Andrew

    2010-01-01

    - or interval - Markov chains allow us to aggregate states in such a way as to safely bound transient probabilities of the original Markov chain. Whilst we can apply this technique directly to a PEPA model, it requires us to obtain the CTMC of the model, whose state space may be too large to construct......Stochastic process algebras such as PEPA allow complex stochastic models to be described in a compositional way, but this leads to state space explosion problems. To combat this, there has been a great deal of work in developing techniques for abstracting Markov chains. In particular, abstract...

  10. Switching transients in the MFTF yin-yang coils

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1982-01-01

    This report is a study of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to the coils' performance tests

  11. Numerical analysis of transient pressure variation in the condenser of a nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xinjun; Zhou, Zijie; Song, Zhao [Xi' an Jiaotong University, Xi' an (China); Lu, Qiankui; Li, Jiafu [Dong Fang Turbine Co., Ltd, Deyang (China)

    2016-02-15

    To research the characteristics of the transient variation of pressure in a nuclear power station condenser under accident condition, a mathematical model was established which simulated the cycling cooling water, heat transfer and pressure in the condenser. The calculation program of transient variation characteristics was established in Fortran language. The pump's parameter, cooling line's organization, check valve's feature and the parameter of siphonic water-collecting well are involved in the cooling water flow's mathematical model. The initial conditions of control volume are determined by the steady state of the condenser. The transient characteristics of a 1000 MW nuclear power station's condenser and cooling water system were examined. The results show that at the condition of plant-power suspension of pump, the cooling water flow rate decreases rapidly and refluxes, then fluctuates to 0. The variation of heat transfer coefficient in the condenser has three stages: at start it decreases sharply, then increases and decreases, and keeps constant in the end. Under three conditions (design, water and summer), the condenser pressure goes up in fluctuation. The time intervals between condenser's pressure signals under three conditions are about 26.4 s, which can fulfill the requirement for safe operation of nuclear power station.

  12. Intelligent simulations for on-line transient analysis

    International Nuclear Information System (INIS)

    Hassberger, J.A.; Lee, J.C.

    1987-01-01

    A unique combination of simulation, parameter estimation and expert systems technology is applied to the problem of diagnosing nuclear power plant transients. Knowledge-based reasoning is ued to monitor plant data and hypothesize about the status of the plant. Fuzzy logic is employed as the inferencing mechanism and an implication scheme based on observations is developed and employed to handle scenarios involving competing failures. Hypothesis testing is performed by simulating the behavior of faulted components using numerical models. A filter has been developed for systematically adjusting key model parameters to force agreement between simulations and actual plant data. Pattern recognition is employed as a decision analysis technique for choosing among several hypotheses based on simulation results. An artificial Intelligence framework based on a critical functions approach is used to deal with the complexity of a nuclear plant system. Detailed simulation results of various nuclear power plant accident scenarios are presented to demonstrate the performance and robustness properties of the diagnostic algorithm developed. The system is shown to be successful in diagnosing and identifying fault parameters for a normal reactor scram, loss-of-feedwater (LOFW) and small loss-of-coolant (LOCA) transients occurring together in a scenario similar to the accident at Three Mile Island

  13. Flow transients experiments with refrigerant-12

    International Nuclear Information System (INIS)

    Celata, G.P.; D'Annibale, F.; Farello, G.E.; Setaro, T.

    1986-01-01

    Flow transients have been investigated in a wide range of thermal-hydraulics situations with Refrigerannt-12. Six pressures (including the reference to PWR and BWR characteristic liquid to vapour densities ratios), several periods of the flowrate transients coastdown during the simulated flow decays, and different specific mass flowrate have been studied emploiyng a circular duct test section (Dsub(i)=7,5 mm). Two heated lengths of the test section have been considered (L = 2300 and 1180 mm). Experimental data have shown the complete inadequacy of steady-state critical heat flux correlations in predicting the onset of boiling crisis during fast flow transients (half-flow decay time, tsub(h)lt5.0-6.0 s). The flow transient does not show dependence, in terms of DNB conditions ,upon the length of the test section: the ratio between transient and steady-state critical mass flowrate is not dependent on the tested geometry. The time interval from the start of the flowrate transient to the onset of DNB (time to crisis), has been experimentally determined for all the runs. Data analysis for a better theoretical prediction of the phenomenon has been accomplished, and a design correlation for DNB conditons and time to crisis prediction has been proposed

  14. Biodegradable elastomers and silicon nanomembranes/nanoribbons for stretchable, transient electronics, and biosensors.

    Science.gov (United States)

    Hwang, Suk-Won; Lee, Chi Hwan; Cheng, Huanyu; Jeong, Jae-Woong; Kang, Seung-Kyun; Kim, Jae-Hwan; Shin, Jiho; Yang, Jian; Liu, Zhuangjian; Ameer, Guillermo A; Huang, Yonggang; Rogers, John A

    2015-05-13

    Transient electronics represents an emerging class of technology that exploits materials and/or device constructs that are capable of physically disappearing or disintegrating in a controlled manner at programmed rates or times. Inorganic semiconductor nanomaterials such as silicon nanomembranes/nanoribbons provide attractive choices for active elements in transistors, diodes and other essential components of overall systems that dissolve completely by hydrolysis in biofluids or groundwater. We describe here materials, mechanics, and design layouts to achieve this type of technology in stretchable configurations with biodegradable elastomers for substrate/encapsulation layers. Experimental and theoretical results illuminate the mechanical properties under large strain deformation. Circuit characterization of complementary metal-oxide-semiconductor inverters and individual transistors under various levels of applied loads validates the design strategies. Examples of biosensors demonstrate possibilities for stretchable, transient devices in biomedical applications.

  15. Challenges in mechanical modeling of SFR fuel rod transient behavior

    Energy Technology Data Exchange (ETDEWEB)

    Feria, F.; Herranz, L. E.

    2013-07-01

    Modeling of SFR fuel rod mechanical behavior under transient conditions entails the development of a creep law to predict cladding viscoplastic strain. In this regard, this work is focused on defining a proper clad creep law structure as the basis to set a suitable model under SFR off-normal conditions as transient overpower and loss of fluid. To do so, a review of in-codes clad creep models has been done by using SAS-SFR, SCANAIR and ASTEC. The proposed creep model has been structured in two parts: viscoplastic behaviour before the failure (primary and secondary creep) and the failure due to viscoplastic collapse (tertiary creep). In order to model the first part, Norton creep law has been proposed as a conservative option. An irradiation hardening factor should be included for best estimate calculations. The recommendation for the second part is to apply a failure criterion based on strain limit or rupture time, which allows achieving conservative results.

  16. Transient two-phase flow

    International Nuclear Information System (INIS)

    Hsu, Y.Y.

    1974-01-01

    The following papers related to two-phase flow are summarized: current assumptions made in two-phase flow modeling; two-phase unsteady blowdown from pipes, flow pattern in Laval nozzle and two-phase flow dynamics; dependence of radial heat and momentum diffusion; transient behavior of the liquid film around the expanding gas slug in a vertical tube; flooding phenomena in BWR fuel bundles; and transient effects in bubble two-phase flow. (U.S.)

  17. A follow-up of transients. Stage 1

    International Nuclear Information System (INIS)

    Enekull, Aa.; Wallner, B.

    1981-09-01

    A follow-up of the transients of temperature and pressure in the primary pressurized system of a nuclear power plant has been completed for the Barsebaeck-1 reactor. The investigation consists of the following steps:- the collation of transients - drawing up load data based on transients-analyses of stress - recommendations for future programs. It was found that the lifetime of the system will exceed 40 years excluding some of the pipes for feed water. The appendices give a detailed description of the transients.(G.B.)

  18. A Methodology to Determine Self-Similarity, Illustrated by Example: Transient Heat Transfer with Constant Flux

    Science.gov (United States)

    Monroe, Charles; Newman, John

    2005-01-01

    This simple example demonstrates the physical significance of similarity solutions and the utility of dimensional and asymptotic analysis of partial differential equations. A procedure to determine the existence of similarity solutions is proposed and subsequently applied to transient constant-flux heat transfer. Short-time expressions follow from…

  19. Discrete oscillator design linear, nonlinear, transient, and noise domains

    CERN Document Server

    Rhea, Randall W

    2014-01-01

    Oscillators are an essential part of all spread spectrum, RF, and wireless systems, and today's engineers in the field need to have a firm grasp on how they are designed. Presenting an easy-to-understand, unified view of the subject, this authoritative resource covers the practical design of high-frequency oscillators with lumped, distributed, dielectric and piezoelectric resonators. Including numerous examples, the book details important linear, nonlinear harmonic balance, transient and noise analysis techniques. Moreover, the book shows you how to apply these techniques to a wide range of os

  20. Rapid-L Operator-Free Fast Reactor Concept Without Any Control Rods

    International Nuclear Information System (INIS)

    Kambe, Mitsuru; Tsunoda, Hirokazu; Mishima, Kaichiro; Iwamura, Takamichi

    2003-01-01

    The 200-kW(electric) uranium-nitride-fueled lithium-cooled fast reactor concept 'RAPID-L' to achieve highly automated reactor operation has been demonstrated. RAPID-L is designed for a lunar base power system. It is one of the variants of the RAPID (Refueling by All Pins Integrated Design) fast reactor concept, which enables quick and simplified refueling. The essential feature of the RAPID concept is that the reactor core consists of an integrated fuel assembly instead of conventional fuel subassemblies. In this small-size reactor core, 2700 fuel pins are integrated and encased in a fuel cartridge. Refueling is conducted by replacing a fuel cartridge. The reactor can be operated without refueling for up to 10 yr.Unique challenges in reactivity control systems design have been addressed in the RAPID-L concept. The reactor has no control rod but involves the following innovative reactivity control systems: lithium expansion modules (LEM) for inherent reactivity feedback, lithium injection modules (LIM) for inherent ultimate shutdown, and lithium release modules (LRM) for automated reactor startup. All these systems adopt 6 Li as a liquid poison instead of B 4 C rods. In combination with LEMs, LIMs, and LRMs, RAPID-L can be operated without an operator. This reactor concept is also applicable to the terrestrial fast reactors. In this paper, the RAPID-L reactor concept and its transient characteristics are presented

  1. Deep level transient spectroscopic investigation of phosphorus-doped silicon by self-assembled molecular monolayers.

    Science.gov (United States)

    Gao, Xuejiao; Guan, Bin; Mesli, Abdelmadjid; Chen, Kaixiang; Dan, Yaping

    2018-01-09

    It is known that self-assembled molecular monolayer doping technique has the advantages of forming ultra-shallow junctions and introducing minimal defects in semiconductors. In this paper, we report however the formation of carbon-related defects in the molecular monolayer-doped silicon as detected by deep-level transient spectroscopy and low-temperature Hall measurements. The molecular monolayer doping process is performed by modifying silicon substrate with phosphorus-containing molecules and annealing at high temperature. The subsequent rapid thermal annealing drives phosphorus dopants along with carbon contaminants into the silicon substrate, resulting in a dramatic decrease of sheet resistance for the intrinsic silicon substrate. Low-temperature Hall measurements and secondary ion mass spectrometry indicate that phosphorus is the only electrically active dopant after the molecular monolayer doping. However, during this process, at least 20% of the phosphorus dopants are electrically deactivated. The deep-level transient spectroscopy shows that carbon-related defects are responsible for such deactivation.

  2. Numerical simulation of time-dependent deformations under hygral and thermal transient conditions

    International Nuclear Information System (INIS)

    Roelfstra, P.E.

    1987-01-01

    Some basic concepts of numerical simulation of the formation of the microstructure of HCP are outlined. The aim is to replace arbitrary terms like aging by more realistic terms like bond density in the xerogel and bonds between hydrating particles of HCP. Actual state parameters such as temperature, humidity and degree of hydration can be determined under transient hygral and thermal conditions by solving numerically a series of appropriate coupled differential equations with given boundary conditions. Shrinkage of a composite structure without crack formation, based on calculated moisture distributions, has been determined with numerical concrete codes. The influence of crack formation, tensile strain-hardening and softening on the total deformation of a quasi-homogeneous drying material has been studied by means of model based on FEM. The difference between shrinkage without crack formation and shrinkage with crack formation can be quantified. Drying shrinkage and creep of concrete cannot be separated. The total deformation depends on the superimposed stress fields. Transient hygral deformation can be realistically predicted if the concept of point properties is applied rigorously. Transient thermal deformation has to be dealt with in the same way. (orig./HP)

  3. An investigation of transient pressures and plasma properties in a pinched plasma column. M.S. Thesis

    Science.gov (United States)

    Stover, E. K.; York, T. M.

    1971-01-01

    The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with several plasma diagnostics; they were: a rapid response pressure transducer, a magnetic field probe, a voltage probe, and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior: (1) strong axial pressure asymmetry noted early in plasma column lifetime, (2) followed by plasma heating in which there is a rapid rise in static pressure, and (3) a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating could be attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity.

  4. Experimental demonstration of a semi-brittle origin for crustal strain transients

    Science.gov (United States)

    Reber, J. E.; Lavier, L. L.; Hayman, N. W.

    2015-12-01

    Tectonic motions that give rise to destructive earthquakes and enigmatic transient slip events are commonly explained by friction laws that describe slip on fault surfaces and gouge-filled zones. Friction laws with the added effects of pore fluid pressure, shear heating, and chemical reactions as currently applied do not take into account that over a wide range of pressure and temperature conditions rocks deform following a complex mixed brittle-ductile rheology. In semi-brittle materials, such as polymineralic rocks, elasto-plastic and visco-elastic defamation can be observed simultaneously in different phases of the material. Field observations of such semi-brittle rocks at the mesoscale have shown that for a given range of composition, temperature, and pressure, the formation of fluid-filled brittle fractures and veins can precede and accompany the development of localized ductile flow. We propose that the coexistence of brittle and viscous behavior controls some of the physical characteristics of strain transients and slow slip events. Here we present results from shear experiments on semi-brittle rock analogues investigating the effect of yield stress on fracture propagation and connection, and how this can lead to reoccurring strain transients. During the experiments we monitor the evolution of fractures and flow as well as the force development in the system. We show that the nature of localized slip and flow in semi-brittle materials depends on the initiation and formation of mode I and II fractures and does not involve frictional behavior, supporting an alternative mechanism for the development of tectonic strain transients.

  5. Manual for operation of the multipurpose thermalhydraulic test facility TOPFLOW (Transient Two Phase Flow Test Facility)

    International Nuclear Information System (INIS)

    Beyer, M.; Carl, H.; Schuetz, H.; Pietruske, H.; Lenk, S.

    2004-07-01

    The Forschungszentrum Rossendorf (FZR) e. V. is constructing a new large-scale test facility, TOPFLOW, for thermalhydraulic single effect tests. The acronym stands for transient two phase flow test facility. It will mainly be used for the investigation of generic and applied steady state and transient two phase flow phenomena and the development and validation of models of computational fluid dynamic (CFD) codes. The manual of the test facility must always be available for the staff in the control room and is restricted condition during operation of personnel and also reconstruction of the facility. (orig./GL)

  6. Imaging of underground karst water channels using an improved multichannel transient Rayleigh wave detecting method.

    Science.gov (United States)

    Zheng, Xuhui; Liu, Lei; Sun, Jinzhong; Li, Gao; Zhou, Fubiao; Xu, Jiemin

    2018-01-01

    Geological and hydrogeological conditions in karst areas are complicated from the viewpoint of engineering. The construction of underground structures in these areas is often disturbed by the gushing of karst water, which may delay the construction schedule, result in economic losses, and even cause heavy casualties. In this paper, an innovative method of multichannel transient Rayleigh wave detecting is proposed by introducing the concept of arrival time difference phase between channels (TDP). Overcoming the restriction of the space-sampling law, the proposed method can extract the phase velocities of different frequency components from only two channels of transient Rayleigh wave recorded on two adjacent detecting points. This feature greatly improves the work efficiency and lateral resolution of transient Rayleigh wave detecting. The improved multichannel transient Rayleigh wave detecting method is applied to the detection of karst caves and fractures in rock mass of the foundation pit of Yan'an Road Station of Guiyang Metro. The imaging of the detecting results clearly reveals the distribution of karst water inflow channels, which provided significant guidance for water plugging and enabled good control over karst water gushing in the foundation pit.

  7. Developing semi-analytical solution for multiple-zone transient storage model with spatially non-uniform storage

    Science.gov (United States)

    Deng, Baoqing; Si, Yinbing; Wang, Jia

    2017-12-01

    Transient storages may vary along the stream due to stream hydraulic conditions and the characteristics of storage. Analytical solutions of transient storage models in literature didn't cover the spatially non-uniform storage. A novel integral transform strategy is presented that simultaneously performs integral transforms to the concentrations in the stream and in storage zones by using the single set of eigenfunctions derived from the advection-diffusion equation of the stream. The semi-analytical solution of the multiple-zone transient storage model with the spatially non-uniform storage is obtained by applying the generalized integral transform technique to all partial differential equations in the multiple-zone transient storage model. The derived semi-analytical solution is validated against the field data in literature. Good agreement between the computed data and the field data is obtained. Some illustrative examples are formulated to demonstrate the applications of the present solution. It is shown that solute transport can be greatly affected by the variation of mass exchange coefficient and the ratio of cross-sectional areas. When the ratio of cross-sectional areas is big or the mass exchange coefficient is small, more reaches are recommended to calibrate the parameter.

  8. A modeling approach for district heating systems with focus on transient heat transfer in pipe networks

    DEFF Research Database (Denmark)

    Mohammadi, Soma; Bojesen, Carsten

    2015-01-01

    the temperature in DH systems. The main focus is on modeling transient heat transfer in pipe networks regarding the time delays between the heat supply unit and the consumers, the heat loss in the pipe networks and the consumers’ dynamic heat loads. A pseudo-dynamic approach is adopted and also the implicit...... district heating networks [DHN] characteristics. This paper is presenting a new developed model, which reflects the thermo-dynamic behavior of DHN. It is designed for tree network topologies. The purpose of the model is to serve as a basis for applying a variety of scenarios towards lowering...... finite element method is applied to simulate transient temperature changes in pipe networks. The model is calculating time series data related to supply temperature to the DHN from heat production units, heat loads and return temperature related to each consumer to calculate dynamic temperature changes...

  9. Rapid die manufacturing using direct laser metal deposition

    CSIR Research Space (South Africa)

    Pereira, MFVT

    2009-01-01

    Full Text Available This paper highlights the work undertaken at the CSIR on the issue of rapid die manufacturing through the application and evaluation of a rapid prototyping technique and coating technologies applied to die components of a high pressure casting die...

  10. Thermal conductivity measurement of the He-ion implanted layer of W using transient thermoreflectance technique

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Shilian; Li, Yuanfei [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Wang, Zhigang [Department of Electronic Engineering, Dalian University of Technology, Dalian 116024 (China); Jia, Yuzhen [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Science and Technology on Reactor Fuel and Materials Laboratory, Nuclear Power Institute of China, Chengdu 610213 (China); Li, Chun [School of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144 (China); Xu, Ben; Chen, Wanqi [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Bai, Suyuan [School of Physics and Electronic Technology, Liaoning Normal University, Dalian 116029 (China); Huang, Zhengxing; Tang, Zhenan [Department of Electronic Engineering, Dalian University of Technology, Dalian 116024 (China); Liu, Wei, E-mail: liuw@mail.tsinghua.edu.cn [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China)

    2017-02-15

    Transient thermoreflectance method was applied on the thermal conductivity measurement of the surface damaged layer of He-implanted tungsten. Uniform damages tungsten surface layer was produced by multi-energy He-ion implantation with thickness of 450 nm. Result shows that the thermal conductivity is reduced by 90%. This technique was further applied on sample with holes on the surface, which was produced by the He-implanted at 2953 K. The thermal conductivity decreases to 3% from the bulk value.

  11. Validation of SCALE4.4a for Calculation of Xe-Sm Transients After a Scram of the BR2 Reactor

    International Nuclear Information System (INIS)

    Kalcheva, S.; Ponsard, B.; Koonen, E.

    2007-01-01

    The aim of this report is to validate the computational modules system SCALE4.4a for evaluation of reactivity changes, macroscopic absorption cross sections and calculations of the positions of the Control Rods during their motion in Xe-Sm transient after a scram of the BR-2 reactor. The rapid shutting down of the reactor by inserting of negative reactivity by the Control Rods is known as a reactor scram. Following reactor scram, a large xenon and samarium buildup occur in the reactor, which may appreciably affect the multiplication factor of the core due to enormous neutron absorption. The validation of the calculations of Xe-Sm transients by SCALE4.4a has been performed on the measurements of the positions of the Control Rods during their motion in Xe-Sm transients of the BR-2 reactor and on comparison with the calculations by the standard procedure XESM, developed at the BR-2 reactor. A final conclusion is made that the SCALE4.4a modules system can be used for evaluation of Xe-Sm transients of the BR-2 reactor. The utilization of the code is simple, the computational time takes from few seconds.

  12. HEDL experimental transient overpower program

    International Nuclear Information System (INIS)

    Hikido, T.; Culley, G.E.

    1976-01-01

    HEDL is conducting a series of experiments to evaluate the performance of Fast Flux Test Facility (FFTF) prototypic fuel pins up to the point of cladding breach. A primary objective of the program is to demonstrate the adequacy of fuel pin and Plant Protective System (PPS) designs for terminated transients. Transient tests of prototypic FFTF fuel pins previously irradiated in the Experimental Breeder Reactor-II (EBR-II) have demonstrated the adequacy of the PPS and fuel pin designs and indicate that a very substantial margin exists between PPS-terminated transients and that required to produce fuel pin cladding failure. Additional experiments are planned to extend the data base to high burnup, high fluence fuel pin specimens

  13. Learning from anticipated and abnormal plant transients

    International Nuclear Information System (INIS)

    Varnado, B.

    1983-01-01

    A report is given of the American Nuclear Society topical meeting on Anticipated and Abnormal Transients in Light Water Reactors held in Jackson, Wyoming in September 1983. Industry involvement in the evaluation of operating experience, human error contributions, transient management, thermal hydraulic modelling, the role of probabilistic risk assessment and the cost of transient incidents are discussed. (U.K.)

  14. The development of the Nuclear Electric core performance and fault transient analysis code package in support of Sizewell B

    International Nuclear Information System (INIS)

    Hall, P.; Hutt, P.

    1994-01-01

    This paper describes Nuclear Electric's (NE) development of an integrated code package in support of all its reactors including Sizewell B, designed for the provision of fuel management design, core performance studies, operational support and fault transient analysis. The package uses the NE general purpose three-dimensional transient reactor physics code PANTHER with cross-sections derived in the PWR case from the LWRWIMS LWR lattice neutronics code. The package also includes ENIGMA a generic fuel performance code and for PWR application VIPRE-01 a subchannel thermal hydraulics code, RELAP5 the system thermal hydraulics transient code and SCORPIO an on-line surveillance system. The paper describes the capabilities and validation of the elements of this package for PWR, how they are coupled within the package and the way in which they are being applied for Sizewell B to on-line surveillance and fault transient analysis. (Author)

  15. Single-event transients (SET) in analog circuits

    International Nuclear Information System (INIS)

    Chen Panxun; Zhou Kaiming

    2006-01-01

    A new phenomenon of single- event upset is introduced. The transient signal is produced in the output of analog circuits after a heavy ion strikes. The transient upset can influence the circuit connected with the output of analog circuits. For example, the output of operational amplifier can be connected with the input of a digital counter, and the pulse of sufficiently high transient output induced by an ion can increase counts of the counter. On the other hand, the transient voltage signal at the output of analog circuits can change the stage of other circuits. (authors)

  16. Hyperkalemia caused by rapid red cell transfusion and the potassium absorption filter

    Directory of Open Access Journals (Sweden)

    Yasuhiko Imashuku

    2017-01-01

    Full Text Available We report a case of transient hyperkalemia during hysterectomy after cesarean section, due to preoperatively undiagnosed placenta accreta that caused unforeseen massive hemorrhage and required rapid red cell transfusion. Hyperkalemia-induced by rapid red cell transfusion is a well-known severe complication of transfusion; however, in patients with sudden massive hemorrhage, rapid red cell transfusion is necessary to save their life. In such cases, it is extremely important to monitor serum potassium levels. For an emergency situation, a system should be developed to ensure sufficient preparation for immediate transfusion and laboratory tests. Furthermore, sufficient stock of preparations to treat hyperkalemia, such as calcium preparations, diuretics, glucose, and insulin is required. Moreover, a transfusion filter that absorbs potassium has been developed and is now available for clinical use in Japan. The filter is easy to use and beneficial, and should be prepared when it is available.

  17. Hyperkalemia caused by rapid red cell transfusion and the potassium absorption filter

    Science.gov (United States)

    Imashuku, Yasuhiko; Kitagawa, Hirotoshi; Mizuno, Takayoshi; Fukushima, Yutaka

    2017-01-01

    We report a case of transient hyperkalemia during hysterectomy after cesarean section, due to preoperatively undiagnosed placenta accreta that caused unforeseen massive hemorrhage and required rapid red cell transfusion. Hyperkalemia-induced by rapid red cell transfusion is a well-known severe complication of transfusion; however, in patients with sudden massive hemorrhage, rapid red cell transfusion is necessary to save their life. In such cases, it is extremely important to monitor serum potassium levels. For an emergency situation, a system should be developed to ensure sufficient preparation for immediate transfusion and laboratory tests. Furthermore, sufficient stock of preparations to treat hyperkalemia, such as calcium preparations, diuretics, glucose, and insulin is required. Moreover, a transfusion filter that absorbs potassium has been developed and is now available for clinical use in Japan. The filter is easy to use and beneficial, and should be prepared when it is available. PMID:28217070

  18. Transient phenomena in electrical power systems

    CERN Document Server

    Venikov, V A; Higinbotham, W

    1964-01-01

    Electronics and Instrumentation, Volume 24: Transient Phenomena in Electrical Power Systems presents the methods for calculating the stability and the transient behavior of systems with forced excitation control. This book provides information pertinent to the analysis of transient phenomena in electro-mechanical systems.Organized into five chapters, this volume begins with an overview of the principal requirements in an excitation system. This text then explains the electromagnetic and electro-mechanical phenomena, taking into account the mutual action between the components of the system. Ot

  19. Transient burnout in flow reduction condition

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Kuroyanagi, Toshiyuki

    1981-01-01

    A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author)

  20. Characterizing SI Engine Transient Fuel Consumption in ALPHA

    Science.gov (United States)

    Examine typical transient engine operation encountered over the EPA's vehicle and engine testing drive cycles to characterize that transient fuel usage, and then describe the changes made to ALPHA to better model transient engine operation.

  1. Nuclear reactors transients identification and classification system

    International Nuclear Information System (INIS)

    Bianchi, Paulo Henrique

    2008-01-01

    This work describes the study and test of a system capable to identify and classify transients in thermo-hydraulic systems, using a neural network technique of the self-organizing maps (SOM) type, with the objective of implanting it on the new generations of nuclear reactors. The technique developed in this work consists on the use of multiple networks to do the classification and identification of the transient states, being each network a specialist at one respective transient of the system, that compete with each other using the quantization error, that is a measure given by this type of neural network. This technique showed very promising characteristics that allow the development of new functionalities in future projects. One of these characteristics consists on the potential of each network, besides responding what transient is in course, could give additional information about that transient. (author)

  2. Analysis of a main steam isolation value closure anticipated transient without scram in a boiling water reactor

    International Nuclear Information System (INIS)

    Liaw, T.J.; Pan, C.; Chen, G.S.

    1989-01-01

    Anticipated transient without scram (ATWS) could be a major accident sequence with possible core melt and containment damage in a boiling water reactor (BWR). The behavior of a BWR/6 during a main steam isolation valve closure ATWS is investigated using the best-estimate computer program, RETRAN-02. The effects of both makeup coolant and boron injection on the reactor behavior are studied. It is found that the BWR/6 behaves similarly to the BWR/2 and BWR/4. Without boron injection and makeup coolant, the reactor loses its coolant inventory very quickly and the reactor power drops rapidly to ∼ 16% of rated power due to negative void reactivity. With coolant makeup from the high-pressure core spray and the reactor core isolation cooling systems, the rector reaches a quasi-steady-state condition after an initially rapidly changing transient. The dome pressure, downcomer water level, and core power oscillate around a mean value; the average core power is ∼ 15%, which is approximately equal to the power needed to heat and evaporate the subcooled makeup coolant. Lower boron concentrations in the core tend to complicate reactor behavior due to the combination of two competing phenomena: the negative boron reactivity and the positive reactivity caused by a void collapse

  3. New developments in French transient monitoring system: SYSFAC From the experiments to the industrial process

    Energy Technology Data Exchange (ETDEWEB)

    Balley, J. [Electricite de France, 69 - Villeurbanne (France). SEPTEN; Bertagnolio, D. [Electricite de France, 69 - Villeurbanne (France). SEPTEN; Faidy, C. [Electricite de France, 69 - Villeurbanne (France). SEPTEN; Kappler, F. [Electricite de France, 69 - Villeurbanne (France). SEPTEN; Kergoat, M. [Electricite de France, 69 - Villeurbanne (France). SEPTEN; L`Huby, Y. [Electricite de France, 69 - Villeurbanne (France). SEPTEN; Genette, P. [Electricite de France, 69 - Villeurbanne (France). SEPTEN; Savoldelli, D. [Electricite de France, Production-Transport DMAINT, 13 Esplanade Charles de Gaulle, 92060 La Defense (France); Fournier, I. [Electricite de France, Direction Etudes et Recherches REME, 25 allee privee, Carrefour Pleyel, 93206 St. Denis (France)

    1995-01-01

    After more than 15 years of experience with regulatory transient data collection, Electricite de France decided to design a new concept of fatigue monitoring system called SYSFAC. This new system is the result of seven years of successful experimentation with fatigue meters. This system will be connected to the on-site data acquisition system without any complementary instrumentation. The SYSFAC system has a modular structure: the mechanical transient module, the functional transient module, the fatigue meters module and the global damage computing module all have a high level of flexibility to be applied to various types of circuits. After the preliminary studies had been achieved, it was decided to undertake the industrial phase of the SYSFAC project. Specific codes on PC computers have been used to validate the basic concepts and the operator interface. Real-size coding will last one year and the first SYSFAC system will be delivered to the pilot power plant by the end of 1995. ((orig.)).

  4. New developments in French transient monitoring system: SYSFAC From the experiments to the industrial process

    International Nuclear Information System (INIS)

    Balley, J.; Fournier, I.

    1995-01-01

    After more than 15 years of experience with regulatory transient data collection, Electricite de France decided to design a new concept of fatigue monitoring system called SYSFAC. This new system is the result of seven years of successful experimentation with fatigue meters. This system will be connected to the on-site data acquisition system without any complementary instrumentation. The SYSFAC system has a modular structure: the mechanical transient module, the functional transient module, the fatigue meters module and the global damage computing module all have a high level of flexibility to be applied to various types of circuits. After the preliminary studies had been achieved, it was decided to undertake the industrial phase of the SYSFAC project. Specific codes on PC computers have been used to validate the basic concepts and the operator interface. Real-size coding will last one year and the first SYSFAC system will be delivered to the pilot power plant by the end of 1995. ((orig.))

  5. Adaptive Time Stepping for Transient Network Flow Simulation in Rocket Propulsion Systems

    Science.gov (United States)

    Majumdar, Alok K.; Ravindran, S. S.

    2017-01-01

    Fluid and thermal transients found in rocket propulsion systems such as propellant feedline system is a complex process involving fast phases followed by slow phases. Therefore their time accurate computation requires use of short time step initially followed by the use of much larger time step. Yet there are instances that involve fast-slow-fast phases. In this paper, we present a feedback control based adaptive time stepping algorithm, and discuss its use in network flow simulation of fluid and thermal transients. The time step is automatically controlled during the simulation by monitoring changes in certain key variables and by feedback. In order to demonstrate the viability of time adaptivity for engineering problems, we applied it to simulate water hammer and cryogenic chill down in pipelines. Our comparison and validation demonstrate the accuracy and efficiency of this adaptive strategy.

  6. Reconsidering the boundary conditions for a dynamic, transient mode I crack problem

    KAUST Repository

    Leise, Tanya

    2008-11-01

    A careful examination of a dynamic mode I crack problem leads to the conclusion that the commonly used boundary conditions do not always hold in the case of an applied crack face loading, so that a modification is required to satisfy the equations. In particular, a transient compressive stress wave travels along the crack faces, moving outward from the loading region on the crack face. This does not occur in the quasistatic or steady state problems, and is a special feature of the transient dynamic problem that is important during the time interval immediately following the application of crack face loading. We demonstrate why the usual boundary conditions lead to a prediction of crack face interpenetration, and then examine how to modify the boundary condition for a semi-infinite crack with a cohesive zone. Numerical simulations illustrate the resulting approach.

  7. Applications of mixed Petrov-Galerkin finite element methods to transient and steady state creep analysis

    International Nuclear Information System (INIS)

    Guerreiro, J.N.C.; Loula, A.F.D.

    1988-12-01

    The mixed Petrov-Galerkin finite element formulation is applied to transiente and steady state creep problems. Numerical analysis has shown additional stability of this method compared to classical Galerkin formulations. The accuracy of the new formulation is confirmed in some representative examples of two dimensional and axisymmetric problems. (author) [pt

  8. Transient voltage control of a DFIG-based wind power plant for suppressing overvoltage using a reactive current reduction loop

    Directory of Open Access Journals (Sweden)

    Geon Park

    2016-01-01

    Full Text Available This paper proposes a transient voltage control scheme of a doubly fed induction generator (DFIG-based wind power plant (WPP using a reactive current reduction loop to suppress the overvoltage at a point of interconnection (POI and DFIG terminal after a fault clearance. The change of terminal voltage of a DFIG is monitored at every predefined time period to detect the fault clearance. If the voltage change exceeds a set value, then the reactive current reduction loop reduces the reactive current reference in the DFIG controller using the step function. The reactive current injection of DFIGs in a WPP is rapidly reduced, and a WPP can rapidly suppress the overvoltage at a fault clearance because the reactive current reference is reduced. Using an electromagnetic transients program–released version (EMTP–RV simulator, the performance of the proposed scheme was validated for a model system comprising 20 units of a 5-MW DFIG considering various scenarios, such as fault and wind conditions. Test results show that the proposed scheme enables a WPP to suppress the overvoltage at the POI and DFIG terminal within a short time under grid fault conditions.

  9. A Transient Fault Recognition Method for an AC-DC Hybrid Transmission System Based on MMC Information Fusion

    Directory of Open Access Journals (Sweden)

    Jikai Chen

    2016-12-01

    Full Text Available At present, the research is still in the primary stage in the process of fault disturbance energy transfer in the multilevel modular converter based high voltage direct current (HVDC-MMC. An urgent problem is how to extract and analyze the fault features hidden in MMC electrical information in further studies on the HVDC system. Aiming at the above, this article analyzes the influence of AC transient disturbance on electrical signals of MMC. At the same time, it is found that the energy distribution of electrical signals in MMC is different for different arms in the same frequency bands after the discrete wavelet packet transformation (DWPT. Renyi wavelet packet energy entropy (RWPEE and Renyi wavelet packet time entropy (RWPTE are proposed and applied to AC transient fault feature extraction from electrical signals in MMC. Using the feature extraction results of Renyi wavelet packet entropy (RWPE, a novel recognition method is put forward to recognize AC transient faults using the information fusion technology. Theoretical analysis and experimental results show that the proposed method is available to recognize transient AC faults.

  10. Rapid expression of transgenes driven by seed-specific constructs in leaf tissue: DHA production

    Directory of Open Access Journals (Sweden)

    Zhou Xue-Rong

    2010-03-01

    Full Text Available Abstract Background Metabolic engineering of seed biosynthetic pathways to diversify and improve crop product quality is a highly active research area. The validation of genes driven by seed-specific promoters is time-consuming since the transformed plants must be grown to maturity before the gene function can be analysed. Results In this study we demonstrate that genes driven by seed-specific promoters contained within complex constructs can be transiently-expressed in the Nicotiana benthamiana leaf-assay system by co-infiltrating the Arabidopsis thaliana LEAFY COTYLEDON2 (LEC2 gene. A real-world case study is described in which we first assembled an efficient transgenic DHA synthesis pathway using a traditional N. benthamiana Cauliflower Mosaic Virus (CaMV 35S-driven leaf assay before using the LEC2-extended assay to rapidly validate a complex seed-specific construct containing the same genes before stable transformation in Arabidopsis. Conclusions The LEC2-extended N. benthamiana assay allows the transient activation of seed-specific promoters in leaf tissue. In this study we have used the assay as a rapid preliminary screen of a complex seed-specific transgenic construct prior to stable transformation, a feature that will become increasingly useful as genetic engineering moves from the manipulation of single genes to the engineering of complex pathways. We propose that the assay will prove useful for other applications wherein rapid expression of transgenes driven by seed-specific constructs in leaf tissue are sought.

  11. Applying Lean principles and Kaizen rapid improvement events in public health practice.

    Science.gov (United States)

    Smith, Gene; Poteat-Godwin, Annah; Harrison, Lisa Macon; Randolph, Greg D

    2012-01-01

    This case study describes a local home health and hospice agency's effort to implement Lean principles and Kaizen methodology as a rapid improvement approach to quality improvement. The agency created a cross-functional team, followed Lean Kaizen methodology, and made significant improvements in scheduling time for home health nurses that resulted in reduced operational costs, improved working conditions, and multiple organizational efficiencies.

  12. Intense transient electric field sensor based on the electro-optic effect of LiNbO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qing, E-mail: yangqing@cqu.edu.cn; Sun, Shangpeng; Han, Rui; Sima, Wenxia; Liu, Tong [State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing, 400044 (China)

    2015-10-15

    Intense transient electric field measurements are widely applied in various research areas. An optical intense E-field sensor for time-domain measurements, based on the electro-optic effect of lithium niobate, has been studied in detail. Principles and key issues in the design of the sensor are presented. The sensor is insulated, small in size (65 mm × 15 mm × 15 mm), and suitable for high-intensity (<801 kV/m) electric field measurements over a wide frequency band (10 Hz–10 MHz). The input/output characteristics of the sensor were obtained and the sensor calibrated. Finally, an application using this sensor in testing laboratory lightning impulses and in measuring transient electric fields during switch-on of a disconnector confirmed that the sensor is expected to find widespread use in transient intense electric field measurement applications.

  13. On the rapid melt quenching

    International Nuclear Information System (INIS)

    Usatyuk, I.I.; Novokhatskij, I.A.; Kaverin, Yu.F.

    1994-01-01

    Specific features of instrumentation of traditionally employed method of melt spinning (rapid quenching), its disadvantages being discussed, were analyzed. The necessity of the method upgrading as applied to the problems of studying fine structure of molten metals and glasses was substantiated. The principle flowsheet of experimental facility for extremely rapid quenching of the melts of metals is described, specificity of its original functional units being considered. The sequence and character of all the principal stages of the method developed were discussed. 18 refs.; 3 figs

  14. An investigation of transient pressure and plasma properties in a pinched plasma column. M.S. Thesis

    Science.gov (United States)

    Stover, E. K.; York, T. M.

    1971-01-01

    The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with the following plasma diagnostics: a special rapid response pressure transducer, a magnetic field probe, a voltage probe and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior; they were in temporal sequence: strong axial pressure asymmetry noted early in plasma column lifetime followed by plasma heating in which there is a rapid rise in static pressure and a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating is attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity. Turbulent heating arising from discharge current excitation of the ion acoustic wave instability is also considered a possible heating mechanism.

  15. Thermohydraulics in rod bundles and critical heat flux in transient conditions in a tube

    International Nuclear Information System (INIS)

    Courtaud, M.; Roumy, R.

    1975-01-01

    After the determination of the scaling factor of Stevens's similitude for the pressure range of pressurized water vectors by comparison of critical heat flux data in from and in water, some examples of studies performed with freon are shown. The efficiency of the mixing vanes of spacer grids has been determined on the mixing phenomenon in single phase on critical heat flux. A calculation performed with the code FLICA using subchannel analysis on freon data transposed in water is in good agreement with the experiment. The influence of the number of spacer grids has been also shown. Critical heat fluxes have been determined in water at 140 bar in steady state and transient conditions on two tubular test sections. During the transient tests the flow rate was reduced by half in 0.5 seconds and the reincreased heat flux and inlet temperature remaining constant. These tests have shown the validity of the method which consists in using a critical heat flux correlation determined in steady state conditions applied with local transient conditions of enthalpy and mass velocity computed with the FLICA code [fr

  16. Are transient and shear wave elastography useful tools in Gaucher disease?

    Science.gov (United States)

    Webb, Muriel; Zimran, Ari; Dinur, Tama; Shibolet, Oren; Levit, Stella; Steinberg, David M; Salomon, Ophira

    2018-02-01

    Up to now, there are no reliable biochemical markers or imaging that could reveal early tissue damage in Gaucher disease. Therefore, we addressed whether elastography technique can serve as a tool for evaluating patients with Gaucher disease. The study included 42 patients with Gaucher disease type I and 33 patients with liver cirrhosis as well as 22 healthy volunteers. Ultrasound and Doppler examination was performed on each participant prior to apply transient and 2D shear wave elastography. In Gaucher disease the median stiffness of the spleen as assessed by transient elastography (TE) and shear wave elastography (SWE) was 35KPa and 22KPa respectively in contrast to the median stiffness of healthy controls (16.95 and 17.5KPa, p=0.0028 and p=0.0002, respectively) and of patients with cirrhosis (45KPa and 34.5KPa, p=0.015 and pGaucher disease from healthy controls and among those with splenomegaly from cirrhotic patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. 3-D transient eddy current calculations for the FELIX cylinder experiments

    International Nuclear Information System (INIS)

    Davey, K.R.; Turner, L.R.

    1986-12-01

    The three-dimensional eddy current transient field problem is formulated first using the U-V method. This method breaks the vector Helmholtz equation into two scalar Helmholtz equations. Null field integral equations and the appropriate boundary conditions are used to set up an identification matrix which is independent of null field point locations. Embedded in the identification matrix are the unknown eigenvalues of the problem representing its impulse response in time. These eigenvalues are found by equating the determinant of the identification matrix to zero. When this initial forcing function is Fourier decomposed into its spatial harmonics, each Fourier component can be associated with a unique eigenvalue by this technique. The true transient solution comes through a convolution of the impulse response so obtained with the particular external field decay governing the problem at hand. The technique is applied to the FELIX cylinder experiments; computed results are compared to data. A pseudoanalytic confirmation of the eigenvalues so obtained is formulated to validate the procedure

  18. Effect of pressure on the transient swelling rate of oxide fuel

    International Nuclear Information System (INIS)

    Gruber, E.E.

    1982-04-01

    An analysis of the transient swelling rate of oxide fuel, based on fission-gas bubble conditions calculated with the FRAS3 code, has been developed and implemented in the code. The need for this capability arises in the coupling of the FRAS3 fission-gas analysis code to the FPIN fuel-pin mechanics code. An efficient means of closely coupling the calculations of swelling strains and stresses between the modules is required. The present analysis provides parameters that allow the FPIN calculation to proceed through a fairly large time step, using estimated swelling rates, to calculate the stresses. These stress values can then be applied in the FRAS3 detailed calculation to refine the swelling calculation, and to provide new values for the parameters to estimate the swelling in the next time step. The swelling rates were calculated for two representative transients and used to estimate swelling over a short time period for various stress levels

  19. Fission gas behavior during fast thermal transients

    International Nuclear Information System (INIS)

    Esteves, R.G.

    1976-01-01

    The behavior of non-equilibrium fission in fuel elements undergoing fast thermal transients is analyzed. To facilitate the analysis, a new variable, the equilibrium variable (EV) is defined. This variable, together with bubble radius, completely specifies a bubble with respect to its size and equilibrium condition. The analysis is coded using a two-variable (radius and EV) multigroup numerical approximation that accepts as input the time-temperature history, the time-fission rate history, and the time-thermal gradient history of the fuel element. Studies were performed to test the code for convergence with respect to the time interval and the number of groups chosen. For a series of transient simulation studies, the measurements obtained at HEDL (microscopic examination of intragranular porosity in oxide fuel transient-tested in TREAT) are used. Two different transient histories were selected; the first, a high-temperature transient (HTT) with a peak at 2477 0 K and the second, a low-temperature transient (LTT) with a peak-temperature at 2000 0 K. The LTT was simulated for three different conditions: Bubbles were allowed to move via (a) only biased migration, (b) via random migration, and (c) via both mechanisms. The HTT was also run for both mechanisms. The agreement with HEDL microscopic observations was fair for bubbles smaller than 964 A in diameter, and poor for larger bubbles. Bubbles that grew during the heat-up part of the transient were frozen at a larger size during the cool down

  20. The economic impact of reactor transients

    International Nuclear Information System (INIS)

    Rossin, A.D.; Vine, G.L.

    1984-01-01

    This chapter discusses the cost estimation of transients and the causal relationship between transients and accidents. It is suggested that the calculation of the actual cost of a transient that has occurred is impossible without computerized records. Six months of operating experience reports, based on a survey of pressurized water reactors (PWRs) and boiling water reactors (BWRs) conducted by the Nuclear Safety Analysis Center (NSAC), are analyzed. The significant costs of a reactor transient are the repair costs resulting from severe damage to plant equipment, the cost of scrams (the actions the system is designed to take to avoid safety risks), US NRC fines, negative publicity, utility rates and revenues. It is estimated that the Three Mile Island-2 accident cost the US over $100 billion in nuclear plant delays and cancellations, more expensive fuel, oil imports, backfits, bureaucratic, administrative and legal costs, and lost productivity

  1. Sulfur driven nucleation mode formation in diesel exhaust under transient driving conditions.

    Science.gov (United States)

    Karjalainen, Panu; Rönkkö, Topi; Pirjola, Liisa; Heikkilä, Juha; Happonen, Matti; Arnold, Frank; Rothe, Dieter; Bielaczyc, Piotr; Keskinen, Jorma

    2014-02-18

    Sulfur driven diesel exhaust nucleation particle formation processes were studied in an aerosol laboratory, on engine dynamometers, and on the road. All test engines were equipped with a combination of a diesel oxidation catalyst (DOC) and a partial diesel particulate filter (pDPF). At steady operating conditions, the formation of semivolatile nucleation particles directly depended on SO2 conversion in the catalyst. The nucleation particle emission was most significant after a rapid increase in engine load and exhaust gas temperature. Results indicate that the nucleation particle formation at transient driving conditions does not require compounds such as hydrocarbons or sulfated hydrocarbons, however, it cannot be explained only by the nucleation of sulfuric acid. A real-world exhaust study with a heavy duty diesel truck showed that the nucleation particle formation occurs even with ultralow sulfur diesel fuel, even at downhill driving conditions, and that nucleation particles can contribute 60% of total particle number emissions. In general, due to sulfur storage and release within the exhaust aftertreatment systems and transients in driving, emissions of nucleation particles can even be the dominant part of modern diesel vehicle exhaust particulate number emissions.

  2. The Studsvik power transient programs Demo-Ramp II and Trans-Ramp I

    International Nuclear Information System (INIS)

    Bergenlid, U.; Lysell, G.; Mogard, H.; Roennberg, G.

    1984-01-01

    The Studsvik Demo-Ramp II och Trans-Ramp I are internationally sponsored research programs. The main objectives are similar in both programs: to study the effects on the PCI/SCC failure process of short time power transients, above the failure threshold where cladding failure (FP leakage) is expected to occur after a sufficient hold time. Demo-Ramp II is completed, whereas, at present, Trans-Ramp I is in progress. Test fuel rods of standard BWR design are used. The fuel rods have been base-irradiated in a power reactor (burn-up in the range 18 to 29 MWd/kg U) and subsequently ramp tested in the R2 reactor. Extensive examinations of the rods have been performed. In the Demo-Ramp II program a large number of incipient cladding cracks were observed to be formed more rapidly than expected, based on previous knowledge. It was possible to operate one rod for a very short time above the failure threshold without SCC crack formation. One objective of the Trans-Ramp I program is to define more closely the power-time region above the failure threshold where the rods remain intact after power transients. (author)

  3. A microcomputer-controlled modulation technique for the detection of transient species in UV photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Lonkhuyzen, H. van; Muller, H.G.; Lange, C.A. de

    1980-01-01

    A microcomputer-controlled modulation method is described to measure UV photoelectron spectra of transient species generated in a microwave discharge. Spectra at low and high microwave power levels are simultaneously recorded and afterwards linearly combined in order to remove parent compound signals. The method is applied to discharged oxygen where the transition O 2 + ( 2 PHIsub(u)) 2 ( 1 Δsub(g)) becomes visible without interference from the parent molecule O 2 ( 3 Σsub(g) - ), and to discharged sulphur dioxide where SO( 3 Σ - ) and S( 3 P) photoelectron spectra are obtained free from SO 2 bands. Finally the build-up of transient bands as a function of time is recorded. (orig.)

  4. Chernobyl reactor transient simulation study

    International Nuclear Information System (INIS)

    Gaber, F.A.; El Messiry, A.M.

    1988-01-01

    This paper deals with the Chernobyl nuclear power station transient simulation study. The Chernobyl (RBMK) reactor is a graphite moderated pressure tube type reactor. It is cooled by circulating light water that boils in the upper parts of vertical pressure tubes to produce steam. At equilibrium fuel irradiation, the RBMK reactor has a positive void reactivity coefficient. However, the fuel temperature coefficient is negative and the net effect of a power change depends upon the power level. Under normal operating conditions the net effect (power coefficient) is negative at full power and becomes positive under certain transient conditions. A series of dynamic performance transient analysis for RBMK reactor, pressurized water reactor (PWR) and fast breeder reactor (FBR) have been performed using digital simulator codes, the purpose of this transient study is to show that an accident of Chernobyl's severity does not occur in PWR or FBR nuclear power reactors. This appears from the study of the inherent, stability of RBMK, PWR and FBR under certain transient conditions. This inherent stability is related to the effect of the feed back reactivity. The power distribution stability in the graphite RBMK reactor is difficult to maintain throughout its entire life, so the reactor has an inherent instability. PWR has larger negative temperature coefficient of reactivity, therefore, the PWR by itself has a large amount of natural stability, so PWR is inherently safe. FBR has positive sodium expansion coefficient, therefore it has insufficient stability it has been concluded that PWR has safe operation than FBR and RBMK reactors

  5. 2D Inversion of Transient Electromagnetic Method (TEM)

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Luís Porsani, Jorge; Acácio Monteiro dos Santos, Fernando

    2017-04-01

    A new methodology was developed for 2D inversion of Transient Electromagnetic Method (TEM). The methodology consists in the elaboration of a set of routines in Matlab code for modeling and inversion of TEM data and the determination of the most efficient field array for the problem. In this research, the 2D TEM modeling uses the finite differences discretization. To solve the inversion problem, were applied an algorithm based on Marquardt technique, also known as Ridge Regression. The algorithm is stable and efficient and it is widely used in geoelectrical inversion problems. The main advantage of 1D survey is the rapid data acquisition in a large area, but in regions with two-dimensional structures or that need more details, is essential to use two-dimensional interpretation methodologies. For an efficient field acquisition we used in an innovative form the fixed-loop array, with a square transmitter loop (200m x 200m) and 25m spacing between the sounding points. The TEM surveys were conducted only inside the transmitter loop, in order to not deal with negative apparent resistivity values. Although it is possible to model the negative values, it makes the inversion convergence more difficult. Therefore the methodology described above has been developed in order to achieve maximum optimization of data acquisition. Since it is necessary only one transmitter loop disposition in the surface for each series of soundings inside the loop. The algorithms were tested with synthetic data and the results were essential to the interpretation of the results with real data and will be useful in future situations. With the inversion of the real data acquired over the Paraná Sedimentary Basin (PSB) was successful realized a 2D TEM inversion. The results indicate a robust geoelectrical characterization for the sedimentary and crystalline aquifers in the PSB. Therefore, using a new and relevant approach for 2D TEM inversion, this research effectively contributed to map the most

  6. Synchronizing noisy nonidentical oscillators by transient uncoupling

    Energy Technology Data Exchange (ETDEWEB)

    Tandon, Aditya, E-mail: adityat@iitk.ac.in; Mannattil, Manu, E-mail: mmanu@iitk.ac.in [Department of Physics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh 208016 (India); Schröder, Malte, E-mail: malte@nld.ds.mpg.de [Network Dynamics, Max Planck Institute for Dynamics and Self-Organization (MPIDS), 37077 Göttingen (Germany); Timme, Marc, E-mail: timme@nld.ds.mpg.de [Network Dynamics, Max Planck Institute for Dynamics and Self-Organization (MPIDS), 37077 Göttingen (Germany); Department of Physics, Technical University of Darmstadt, 64289 Darmstadt (Germany); Chakraborty, Sagar, E-mail: sagarc@iitk.ac.in [Department of Physics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh 208016 (India); Mechanics and Applied Mathematics Group, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh 208016 (India)

    2016-09-15

    Synchronization is the process of achieving identical dynamics among coupled identical units. If the units are different from each other, their dynamics cannot become identical; yet, after transients, there may emerge a functional relationship between them—a phenomenon termed “generalized synchronization.” Here, we show that the concept of transient uncoupling, recently introduced for synchronizing identical units, also supports generalized synchronization among nonidentical chaotic units. Generalized synchronization can be achieved by transient uncoupling even when it is impossible by regular coupling. We furthermore demonstrate that transient uncoupling stabilizes synchronization in the presence of common noise. Transient uncoupling works best if the units stay uncoupled whenever the driven orbit visits regions that are locally diverging in its phase space. Thus, to select a favorable uncoupling region, we propose an intuitive method that measures the local divergence at the phase points of the driven unit's trajectory by linearizing the flow and subsequently suppresses the divergence by uncoupling.

  7. Modeling of transient electroluminescence overshoot in bilayer organic light-emitting diodes using rate equations

    International Nuclear Information System (INIS)

    Chandra, V.K.; Chandra, B.P.; Tiwari, M.; Baghel, R.N.; Ramrakhiani, M.

    2012-01-01

    expressions are derived for the transient EL intensity I, time t m and intensity I m corresponding to the peak of EL overshoot, total EL intensity I t and decay of the intensity of EL overshoot. In fact, the decay prior to the onset of EL overshoot is the decay of number of electrons moving in the electron transporting states. The ratio I m /I s decreases with increasing value of the applied pulse voltage because I m increases linearly with the amplitude of applied voltage pulse and I s increases nonlinearly and rapidly with the increasing amplitude of applied voltage pulse. The lifetime τ t of electrons at the interface decreases with increasing temperature whereby the dependence of τ t on temperature follows Arrhenius plot. This fact indicates that the detrapping involves thermally-assisted tunneling of electrons. Using the EL overshoot in bilayer OLEDs, the lifetime of the charge carriers at the interface, recombination time of charge carriers, decay time of the EL prior to onset of overshoot, and the time delay between the voltage pulse and onset time of the EL overshoot can be determined. The intense EL overshoot of nanosecond or shorter time duration may be useful in digital communication, and moreover, the EL overshoot gives important information about the processes involving injection, transport and recombination of charge carriers. The criteria for appearance of EL overshoot in bilayer OLEDs are explored. A good agreement is found between the theoretical and experimental results. - Highlights: ► Modeling is done for transient electroluminescence overshoot in bilayer OLEDs. ► Overshoot in spin-coated bilayer OLEDs is caused by the presence of an interfacial layer. ► Expressions are derived for the transient EL intensity and decay of EL in OLEDs. ► A good agreement is found between the theoretical and experimental results.

  8. Modeling of transient electroluminescence overshoot in bilayer organic light-emitting diodes using rate equations

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, V.K. [Department of Electrical and Electronics Engineering, Chhatrapati Shivaji Institute of Technology, Shivaji Nagar, Kolihapuri, Durg 491001 (C.G.) (India); Chandra, B.P., E-mail: bpchandra4@yahoo.co.in [Department of Applied Physics, Ashoka Institute of Technology and Management, Rajnandgaon 491441 (C.G.) (India); Tiwari, M. [Department of Postgraduate Studies and Research in Physics and Electronics, Rani Durgavati University, Jabalpur 482001 (M.P.) (India); Baghel, R.N. [School of Studies in Physics and Astrophysics, Pt. Ravishankar Shukla University, Raipur 492010 (C.G.) (India); Ramrakhiani, M. [Department of Postgraduate Studies and Research in Physics and Electronics, Rani Durgavati University, Jabalpur 482001 (M.P.) (India)

    2012-06-15

    expressions are derived for the transient EL intensity I, time t{sub m} and intensity I{sub m} corresponding to the peak of EL overshoot, total EL intensity I{sub t} and decay of the intensity of EL overshoot. In fact, the decay prior to the onset of EL overshoot is the decay of number of electrons moving in the electron transporting states. The ratio I{sub m}/I{sub s} decreases with increasing value of the applied pulse voltage because I{sub m} increases linearly with the amplitude of applied voltage pulse and I{sub s} increases nonlinearly and rapidly with the increasing amplitude of applied voltage pulse. The lifetime {tau}{sub t} of electrons at the interface decreases with increasing temperature whereby the dependence of {tau}{sub t} on temperature follows Arrhenius plot. This fact indicates that the detrapping involves thermally-assisted tunneling of electrons. Using the EL overshoot in bilayer OLEDs, the lifetime of the charge carriers at the interface, recombination time of charge carriers, decay time of the EL prior to onset of overshoot, and the time delay between the voltage pulse and onset time of the EL overshoot can be determined. The intense EL overshoot of nanosecond or shorter time duration may be useful in digital communication, and moreover, the EL overshoot gives important information about the processes involving injection, transport and recombination of charge carriers. The criteria for appearance of EL overshoot in bilayer OLEDs are explored. A good agreement is found between the theoretical and experimental results. - Highlights: Black-Right-Pointing-Pointer Modeling is done for transient electroluminescence overshoot in bilayer OLEDs. Black-Right-Pointing-Pointer Overshoot in spin-coated bilayer OLEDs is caused by the presence of an interfacial layer. Black-Right-Pointing-Pointer Expressions are derived for the transient EL intensity and decay of EL in OLEDs. Black-Right-Pointing-Pointer A good agreement is found between the theoretical and

  9. Essential role of transient receptor potential M8 (TRPM8) in a model of acute cold-induced urinary urgency.

    Science.gov (United States)

    Uvin, Pieter; Franken, Jan; Pinto, Silvia; Rietjens, Roma; Grammet, Luc; Deruyver, Yves; Alpizar, Yeranddy A; Talavera, Karel; Vennekens, Rudi; Everaerts, Wouter; De Ridder, Dirk; Voets, Thomas

    2015-10-01

    Acute exposure of part of the skin to cold stimuli can evoke urinary urgency, a phenomenon termed acute cold-induced urgency (ACIU). Despite its high prevalence, particularly in patients with overactive bladder, little is known about the mechanisms that induce ACIU. To develop an animal model of ACIU and test the involvement of cold-activated ion channels transient receptor potential (TRP) M8 and TRPA1. Intravesical pressure and micturition were monitored in female mice (wild-type C57BL/6J, Trpa1(-/-), Trpm8(+/+), and Trpm8(-/-)) and Sprague Dawley rats. An intravesical catheter was implanted. Localized cooling of the skin was achieved using a stream of air or topical acetone. The TRPM8 antagonist (N-(3-aminopropyl)-2-{[(3-methylphenyl) methyl]oxy}-N-(2-thienylmethyl)benzamide (AMTB) or vehicle was injected intraperitoneally. Frequencies of bladder contractions and voids in response to sensory stimuli were compared using the Mann-Whitney or Kruskal-Wallis test. Brief, innocuously cold stimuli applied to different parts of the skin evoked rapid bladder contractions and voids in anesthetized mice and rats. These responses were strongly attenuated in Trpm8(-/-) mice and in rats treated with AMTB. As rodent bladder physiology differs from that of humans, it is difficult to directly extrapolate our findings to human patients. Our findings indicate that ACIU is an evolutionarily conserved reflex rather than subconscious conditioning, and provide a useful in vivo model for further investigation of the underlying mechanisms. Pharmacological inhibition of TRPM8 may be useful for treating ACIU symptoms in patients. Brief cold stimuli applied to the skin can evoke a sudden desire to urinate, which can be highly bothersome in patients with overactive bladder. We developed an animal model to study this phenomenon, and found that it depends on a specific molecular cold sensor, transient receptor potential M8 (TRPM8). Pharmacological inhibition of TRPM8 may alleviate acute cold

  10. Unconventional Imaging Methods to Capture Transient Structures during Actomyosin Interaction

    Directory of Open Access Journals (Sweden)

    Eisaku Katayama

    2018-05-01

    Full Text Available Half a century has passed since the cross-bridge structure was recognized as the molecular machine that generates muscle tension. Despite various approaches by a number of scientists, information on the structural changes in the myosin heads, particularly its transient configurations, remains scant even now, in part because of their small size and rapid stochastic movements during the power stroke. Though progress in cryo-electron microscopy is eagerly awaited as the ultimate means to elucidate structural details, the introduction of some unconventional methods that provide high-contrast raw images of the target protein assemblies is quite useful, if available, to break the current impasse. Quick-freeze deep–etch–replica electron microscopy coupled with dedicated image analysis procedures, and high-speed atomic-force microscopy are two such candidates. We have applied the former to visualize actin-associated myosin heads under in vitro motility assay conditions, and found that they take novel configurations similar to the SH1–SH2-crosslinked myosin that we characterized recently. By incorporating biochemical and biophysical results, we have revised the cross-bridge mechanism to involve the new conformer as an important main player. The latter “microscopy” is unique and advantageous enabling continuous observation of various protein assemblies as they function. Direct observation of myosin-V’s movement along actin filaments revealed several unexpected behaviors such as foot-stomping of the leading head and unwinding of the coiled-coil tail. The potential contribution of these methods with intermediate spatial resolution is discussed.

  11. CEDNBR: a computer code for transient thermal margin analysis of a reactor core

    International Nuclear Information System (INIS)

    Shesler, A.T.; Lehmann, C.R.

    1976-09-01

    The report describes the CEDNBR computer code. This code was developed for the transient thermal analysis of a pressurized water reactor core or a critical heat flux test. Included are the code structure, conservation equations, and correlations utilized by CEDNBR. The methods of modelling a reactor core and hot channel and a CHF test are presented. Comparisons of CEDNBR calculations are made with both empirical pressure loss data and simulated loss of flow test data. The code solves the one-dimensional conservation of mass, energy, and momentum equations and the equation of state for the fluid for either steady-state or transient conditions. Tabular time dependent functions of inlet temperatures, pressure, mass velocity, axial heat flux distributions, normalized heat flux, radial peaking factors, and incremental mixing factors are required input to the code. Transient effects are included in the calculation of enthalpy rise and fluid properties. The Departure from Nucleate Boiling Ratio (DNBR) is calculated by applying a Critical Heat Flux (CHF) correlation to the computed local fluid properties. A code user's guide is provided for preparing input to the code. In addition, descriptions of the sub-routines used by CEDNBR are given

  12. Transient and accident analyses topical design basis documents

    International Nuclear Information System (INIS)

    Chi, Larry; Eckert, Eugene; Grim, Brit

    2004-01-01

    The designers and operators of nuclear power plants have extensively documented system functions, licensing performance, and operating procedures for all conditions. This paper presents a complementary, systematic approach for the documentation of all requirements that are based on the analysis of operational transients, abnormal transients, accidents, and other events which are included in the design and licensing basis for the plant. Up to now, application of the approach has focused on required mitigation actions (automatic or manual). All mitigation actions are directly identified with all applicable reactor events, as well as the plant-unique systems that work together to perform each function. The approach is also applicable to all operational functions. The approach makes extensive use of data base methods, thereby providing effective ways to interrogate the information for the varied users of this information. Examples of use include: evaluations of system design changes and equipment modifications, safety evaluations of any plant change (e.g., USNRC 10CFR50.59 review), plant operations (e.g., manual actions during unplanned events), system interactions, classification of safety-related equipment, environmental qualification of equipment, and mitigation requirements for different reactor operating states. This approach has been applied in customized ways to several boiling water reactor (BWR) units, based on the desires and needs of the specific utility. (author)

  13. Pressurizer and steam-generator behavior under PWR transient conditions

    International Nuclear Information System (INIS)

    Wahba, A.B.; Berta, V.T.; Pointner, W.

    1983-01-01

    Experiments have been conducted in the Loss-of-Fluid Test (LOFT) pressurized water reactor (PWR), at the Idaho National Engineering Laboratory, in which transient phenomena arising from accident events with and without reactor scram were studied. The main purpose of the LOFT facility is to provide data for the development of computer codes for PWR transient analyses. Significant thermal-hydraulic differences have been observed between the measured and calculated results for those transients in which the pressurizer and steam generator strongly influence the dominant transient phenomena. Pressurizer and steam generator phenomena that occurred during four specific PWR transients in the LOFT facility are discussed. Two transients were accompanied by pressurizer inflow and a reduction of the heat transfer in the steam generator to a very small value. The other two transients were accompanied by pressurizer outflow while the steam generator behavior was controlled

  14. Implicit analysis of the transient water flow with dissolved air

    Directory of Open Access Journals (Sweden)

    J. Twyman

    2018-01-01

    Full Text Available The implicit finite-difference method (IFDM for solving a system that transports water with dissolved air using a fixed (or variable rectangular space-time mesh defined by the specified time step method is applied. The air content in the fluid modifies both the wave speed and the Courant number, which makes it inconvenient to apply the traditional Method of Characteristics (MOC and other explicit schemes due to their impossibility to simulate the changes in magnitude, shape and frequency of the pressures train. The conclusion is that the IFDM delivers an accurate and stable solution, with a good adjustment level with respect to a classical case reported in the literature, being a valid alternative for the transient solution in systems that transport water with dissolved air.

  15. Transient analysis capabilities at ABB-CE

    International Nuclear Information System (INIS)

    Kling, C.L.

    1992-01-01

    The transient capabilities at ABB-Combustion Engineering (ABB-CE) Nuclear Power are a function of the computer hardware and related network used, the computer software that has evolved over the years, and the commercial technical exchange agreements with other related organizations and customers. ABB-CEA is changing from a mainframe/personal computer network to a distributed workstation/personal computer local area network. The paper discusses computer hardware, mainframe computing, personal computers, mainframe/personal computer networks, workstations, transient analysis computer software, design/operation transient analysis codes, safety (licensed) analysis codes, cooperation with ABB-Atom, and customer support

  16. Evaluation of LWR fuel rod behavior under operational transient conditions

    International Nuclear Information System (INIS)

    Nakamura, M.; Hiramoto, K.; Maru, A.

    1984-01-01

    To evaluate the effects of fission gas flow and diffusion in the fuel-cladding gap on fuel rod thermal and mechanical behaviors in light water reactor (LWR) fuel rods under operational transient conditions, computer sub-programs which can calculate the gas flow and diffusion have been developed and integrated into the LWR fuel rod performance code BEAF. This integrated code also calculates transient temperature distribution in the fuel-pellet and cladding. The integrated code was applied to an analysis of Inter Ramp Project data, which showed that by taking into account the gas flow and diffusion effects, the calculated cladding damage indices predicted for the failed rods in the ramp test were consistent with iodine-SCC (Stress Corrosion Cracking) failure conditions which were obtained from out-of-reactor pressurized tube experiments with irradiated Zircaloy claddings. This consistency was not seen if the gas flow and diffusion effects were neglected. Evaluation were also made for the BWR 8x8 RJ fuel rod temperatures under power ramp conditions. (orig.)

  17. Transient analysis of DTT rakes

    International Nuclear Information System (INIS)

    Kamath, P.S.; Lahey, R.T. Jr.

    1981-01-01

    This paper presents an analytical model for the determination of the cross-sectionally averaged transient mass flux of a two-phase fluid flowing in a conduit instrumented by a Drag-Disk Turbine Transducer (DTT) Rake and a multibeam gamma densitometer. Parametric studies indicate that for a typical blowdown transient, dynamic effects such as rotor inertia can be important for the turbine-meter. In contrast, for the drag-disk, a frequency response analysis showed that the quasisteady solution is valid below a forcing frequency of about 10 Hz, which is faster than the time scale normally encountered during blowdowns. The model showed reasonably good agreement with full scale transient rake data, where the flow regimes were mostly homogeneous or stratified, thus indicating that the model is suitable for the analysis of a DTT rake. (orig.)

  18. RFSP simulations of Darlington FINCH refuelling transient

    International Nuclear Information System (INIS)

    Carruthers, E.V.; Chow, H.C.

    1997-01-01

    Immediately after refuelling of a channel, the fresh bundles are free of fission products. Xenon-135, the most notable of the saturating fission products, builds up to an equilibrium level in about 30 h. The channel power of the refuelled channel would therefore initially peak and then drop to a steady-state level. The RFSP code can track saturating-fission-product transients and power transients. The Fully INstrumented CHannels (FINCHs) in Darlington NGS provides channel power data on the refuelling power transients. In this paper, such data has been used to identify the physical evidence of the fission-product transient effect on channel power, and to validate RFSP fission-product-driver calculation results. (author)

  19. Research on the improvement of nuclear safety -Development of a nuclear power plant system analysis code TASS (Transient and setpoint simulation)

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Suk Koo; Jang, Won Pyo; Kim, Heui Chul; Kim, Kyung Doo; Lee, Sung Jae; Hah, Kyooi Suk; Song, Soon Jah; Um, Kil Sub; Yoon, Han Yung; Kim, Doo Il; Yoo, Hyung Keun; Choi, Jae Don; Lee, Byung Il; Kim, Jung Jin [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-07-01

    During the third year of the project the development of TASS 1.0 code has been completed and validated its capability in applying for the licensing transient analyses of the Westinghouse and CE type operating reactors as well as the PWR reactors under construction in Korea. The validation of the TASS 1.0 code has been achieved through the comparison calculations of the YGN-3/4 FSAR transients, Kori-3 loss of AC power transient, plant data, Kori-4 load rejection and YGN-3 startup test data as well as the BETHSY loop steam generator tube rupture test data. TASS 1.0 calculation agrees well with the best estimate RELAP5/MOD 3.1 calculation for the YGN-3/4 FASR transients and shows its capability in simulating plant transient and startup data as well as the thermal hydraulic transient test data. Topical reports on TASS 1.0 code have been prepared and will be submitted to Korea Institute of Nuclear Safety for its licensing application to Westinghouse and CE type PWR transient analyses. The development of TASS 2.0 code has been head started in this year to timely utilize the TASS 2.0 code for the KNGR design certification. 65 figs, 30 tabs, 44 refs. (Author).

  20. BWR transient analysis using neutronic / thermal hydraulic coupled codes including uncertainty quantification

    International Nuclear Information System (INIS)

    Hartmann, C.; Sanchez, V.; Tietsch, W.; Stieglitz, R.

    2012-01-01

    The KIT is involved in the development and qualification of best estimate methodologies for BWR transient analysis in cooperation with industrial partners. The goal is to establish the most advanced thermal hydraulic system codes coupled with 3D reactor dynamic codes to be able to perform a more realistic evaluation of the BWR behavior under accidental conditions. For this purpose a computational chain based on the lattice code (SCALE6/GenPMAXS), the coupled neutronic/thermal hydraulic code (TRACE/PARCS) as well as a Monte Carlo based uncertainty and sensitivity package (SUSA) has been established and applied to different kind of transients of a Boiling Water Reactor (BWR). This paper will describe the multidimensional models of the plant elaborated for TRACE and PARCS to perform the investigations mentioned before. For the uncertainty quantification of the coupled code TRACE/PARCS and specifically to take into account the influence of the kinetics parameters in such studies, the PARCS code has been extended to facilitate the change of model parameters in such a way that the SUSA package can be used in connection with TRACE/PARCS for the U and S studies. This approach will be presented in detail. The results obtained for a rod drop transient with TRACE/PARCS using the SUSA-methodology showed clearly the importance of some kinetic parameters on the transient progression demonstrating that the coupling of a best-estimate coupled codes with uncertainty and sensitivity tools is very promising and of great importance for the safety assessment of nuclear reactors. (authors)

  1. Rapid depressurization event analysis in BWR/6 using RELAP5 and contain

    Energy Technology Data Exchange (ETDEWEB)

    Mueftueoglu, A.K.; Feltus, M.A. [Pennsylvania State Univ., University Park, PA (United States)

    1995-09-01

    Noncondensable gases may become dissolved in Boiling Water Reactor (BWR) water level instrumentation during normal operations. Any dissolved noncondensable gases inside these water columns may come out of solution during rapid depressurization events, and displace water from the reference leg piping resulting in a false high level. These water level errors may cause a delay or failure in actuation, or premature shutdown of the Emergency Core Cooling System. (ECCS). If a rapid depressurization causes an erroneously high water level, preventing automatic ECCS actuation, it becomes important to determine if there would be other adequate indications for operator response and other signals for automatic actuation such as high drywell pressure. It is also important to determine the effect of the level signal on ECCS operation after it is being actuated. The objective of this study is to determine the detailed coupled containment/NSSS response during this rapid depressurization events in BWR/6. The selected scenarios involve: (a) inadvertent opening of all ADS valves, (b) design basis (DB) large break loss of coolant accident (LOCA), and (c) main steam line break (MSLB). The transient behaviors are evaluated in terms of: (a) vessel pressure and collapsed water level response, (b) specific transient boundary conditions, (e.g., scram, MSIV closure timing, feedwater flow, and break blowdown rates), (c) ECCS initiation timing, (d) impact of operator actions, (e) whether indications besides low-low water level were available. The results of the analysis had shown that there would be signals to actuate ECCS other than low reactor level, such as high drywell pressure, low vessel pressure, high suppression pool temperature, and that the plant operators would have significant indications to actuate ECCS.

  2. Transient Oscilliations in Mechanical Systems of Automatic Control with Random Parameters

    Science.gov (United States)

    Royev, B.; Vinokur, A.; Kulikov, G.

    2018-04-01

    Transient oscillations in mechanical systems of automatic control with random parameters is a relevant but insufficiently studied issue. In this paper, a modified spectral method was applied to investigate the problem. The nature of dynamic processes and the phase portraits are analyzed depending on the amplitude and frequency of external influence. It is evident from the obtained results, that the dynamic phenomena occurring in the systems with random parameters under external influence are complex, and their study requires further investigation.

  3. The LOFAR Transients Key Science Project

    NARCIS (Netherlands)

    Stappers, B.; Fender, R.; Wijers, R.

    2009-01-01

    The Transients Key Science Project (TKP) is one of six Key Science Projects of the next generation radio telescope LOFAR. Its aim is the study of transient and variable low-frequency radio sources with an extremely broad science case ranging from relativistic jet sources to pulsars, exoplanets,

  4. A new oxidation flow reactor for measuring secondary aerosol formation of rapidly changing emission sources

    Science.gov (United States)

    Simonen, Pauli; Saukko, Erkka; Karjalainen, Panu; Timonen, Hilkka; Bloss, Matthew; Aakko-Saksa, Päivi; Rönkkö, Topi; Keskinen, Jorma; Dal Maso, Miikka

    2017-04-01

    Oxidation flow reactors (OFRs) or environmental chambers can be used to estimate secondary aerosol formation potential of different emission sources. Emissions from anthropogenic sources, such as vehicles, often vary on short timescales. For example, to identify the vehicle driving conditions that lead to high potential secondary aerosol emissions, rapid oxidation of exhaust is needed. However, the residence times in environmental chambers and in most oxidation flow reactors are too long to study these transient effects ( ˜ 100 s in flow reactors and several hours in environmental chambers). Here, we present a new oxidation flow reactor, TSAR (TUT Secondary Aerosol Reactor), which has a short residence time ( ˜ 40 s) and near-laminar flow conditions. These improvements are achieved by reducing the reactor radius and volume. This allows studying, for example, the effect of vehicle driving conditions on the secondary aerosol formation potential of the exhaust. We show that the flow pattern in TSAR is nearly laminar and particle losses are negligible. The secondary organic aerosol (SOA) produced in TSAR has a similar mass spectrum to the SOA produced in the state-of-the-art reactor, PAM (potential aerosol mass). Both reactors produce the same amount of mass, but TSAR has a higher time resolution. We also show that TSAR is capable of measuring the secondary aerosol formation potential of a vehicle during a transient driving cycle and that the fast response of TSAR reveals how different driving conditions affect the amount of formed secondary aerosol. Thus, TSAR can be used to study rapidly changing emission sources, especially the vehicular emissions during transient driving.

  5. Transient cognitive dynamics, metastability, and decision making.

    Directory of Open Access Journals (Sweden)

    Mikhail I Rabinovich

    2008-05-01

    Full Text Available The idea that cognitive activity can be understood using nonlinear dynamics has been intensively discussed at length for the last 15 years. One of the popular points of view is that metastable states play a key role in the execution of cognitive functions. Experimental and modeling studies suggest that most of these functions are the result of transient activity of large-scale brain networks in the presence of noise. Such transients may consist of a sequential switching between different metastable cognitive states. The main problem faced when using dynamical theory to describe transient cognitive processes is the fundamental contradiction between reproducibility and flexibility of transient behavior. In this paper, we propose a theoretical description of transient cognitive dynamics based on the interaction of functionally dependent metastable cognitive states. The mathematical image of such transient activity is a stable heteroclinic channel, i.e., a set of trajectories in the vicinity of a heteroclinic skeleton that consists of saddles and unstable separatrices that connect their surroundings. We suggest a basic mathematical model, a strongly dissipative dynamical system, and formulate the conditions for the robustness and reproducibility of cognitive transients that satisfy the competing requirements for stability and flexibility. Based on this approach, we describe here an effective solution for the problem of sequential decision making, represented as a fixed time game: a player takes sequential actions in a changing noisy environment so as to maximize a cumulative reward. As we predict and verify in computer simulations, noise plays an important role in optimizing the gain.

  6. Transient analysis for Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Ramos Pablos, J.C. et.al.

    1991-01-01

    Relationship between transients analysis and safety of Laguna Verde nuclear power plant is described a general panorama of safety thermal limits of a nuclear station, as well as transients classification and events simulation codes are exposed. Activities of a group of transients analysis of electrical research institute are also mentioned (Author)

  7. Rapidly curable electrically conductive clear coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, Mark P.; Anderson, Lawrence G.; Post, Gordon L.

    2018-01-16

    Rapidly curable electrically conductive clear coatings are applied to substrates. The electrically conductive clear coating includes to clear layer having a resinous binder with ultrafine non-stoichiometric tungsten oxide particles dispersed therein. The clear coating may be rapidly cured by subjecting the coating to infrared radiation that heats the tungsten oxide particles and surrounding resinous binder. Localized heating increases the temperature of the coating to thereby thermally cure the coating, while avoiding unwanted heating of the underlying substrate.

  8. [Transient amnesia in the elderly].

    Science.gov (United States)

    Sellal, François

    2006-03-01

    The two main aetiologies of transient amnesia in the elderly are idiopathic transient global amnesia (TGA) and iatrogenic or toxic amnesia. Vascular and epileptic amnesia are less common. According to the literature, transient psychogenic amnesia, which is a frequent cause of amnesia at age 30 to 50, is very rare in the elderly. TGA is the prototypical picture of transient amnesia. It occurs more often after age 50, with no identified cause, even if some authors accept emotional stress or minor head trauma as occasional precipitants. The mechanism of TGA remains a matter of discussion. It may be the consequence of a spreading depression similar to that described in migraine with aura, but other arguments support an ischemic mechanism. Iatrogenic amnesias are mainly caused by benzodiazepines (BZs) or anticholinergics. The former may occur in a non-anxious subject, who is not a usual consumer of BZ and takes a single dose. The latter are more often due to a hypersensitivity to anticholinergic drugs, in particular in patients presenting with a covert, incipient Alzheimer's disease. A vascular origin must be considered when amnesia is accompanied by other neurological symptoms, and when the regression of the amnesic disorder is slow, lasting several days. It results from lesions involving various mechanisms and locations, mainly subcortical. Partial seizures, most often mesio-temporal, more rarely frontal, may be the cause of transient amnesia in the elderly, in the absence of a past history of epilepsy. The red flag supportive of an epileptic origin is the repetition of stereotyped amnesic episodes. EEG demonstration of seizures may be difficult and the response to antiepileptic drugs effective on partial seizures is usually good.

  9. Fast relaxation transients in a kicked damped oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Urquizu, Merce [Laboratori d' Estudis Geofisics ' Eduard Fontsere' , IEC, Barcelona (Spain); Correig, Antoni M. [Departament d' Astronomical i Meteorologia, Laboratori d' Estudis Geofisics Eduard Fontsere, UB Marti Franques 1, E-08028 Barcelona (Spain) and Laboratori d' Estudis Geofisics ' Eduard Fontsere' , IEC, Barcelona (Spain)]. E-mail: ton.correig@am.ub.es

    2007-08-15

    Although nonlinear relaxation transients are very common in nature, very few studies are devoted to its characterization, mainly due to its short time duration. In this paper, we present a study about the nature of relaxation transients in a kicked damped oscillator, in which transients are generated in terms of continuous fast changes in the parameters of the system. We have found that transient dynamics can be described, rather than in terms of bifurcation dynamics, in terms of instantaneous stretching factors, which are related to the stability of fixed points of the corresponding stroboscopic maps.

  10. Development of a transient criticality evaluation method

    International Nuclear Information System (INIS)

    Pain, C.C.; Eaton, M.D.; Miles, B.; Ziver, A.K.; Gomes, J.L.M.A.; Umpleby, A.P.; Piggott, M.D.; Goddard, A.J.H.; Oliveira, C.R.E. de

    2005-01-01

    In developing a transient criticality evaluation method we model, in full spatial/temporal detail, the neutron fluxes and consequent power and the evolving material properties - their flows, energies, phase changes etc. These methods are embodied in the generic method FETCH code which is based as far as possible on basic principles and is capable of use in exploring safety-related situations somewhat beyond the range of experiment. FETCH is a general geometry code capable of addressing a range of criticality issues in fissile materials. The code embodies both transient radiation transport and transient fluid dynamics. Work on powders, granular materials, porous media and solutions is reviewed. The capability for modelling transient criticality for chemical plant, waste matrices and advanced reactors is also outlined. (author)

  11. Transient hypothyroidism after 131I treatment of Graves disease

    International Nuclear Information System (INIS)

    Liu Jianfeng; Fang Yi; Zhang Xiuli; Ye Genyao; Xing Jialiu; Zhang Youren

    2003-01-01

    Objective: To evaluate the results of the transient hypothyroidism after 131 I treatment of Graves disease. Methods: A total of 32 transient hypothyroidism patients treated with 131 I for Graves disease were studied and followed up. Results: Transient hypothyroidism occurred within 2-6 months after 131 I treatment and 19 patients were symptomatic. At diagnosis of transient hypothyroidism, T 3 and T 4 levels were decreased had normal, TSH levels were increased, normal or low. Follow-up examination found that 20 patients were normal and 12 patients had relapse of hyperthyroidism. Conclusions: Therapy of Graves disease with low doses of 131 I causes a high incidence of transient hypothyroidism. After recovery of transient hypothyroidism, some patients have relapse of hyperthyroidism

  12. Applying an improved rapid impact assessment matrix method to strategic environmental assessment of urban planning in China

    Energy Technology Data Exchange (ETDEWEB)

    Li, Wei, E-mail: weili@bnu.edu.cn; Xie, Yuanbo, E-mail: former_007@163.com; Hao, Fanghua, E-mail: fanghua@bnu.edu.cn

    2014-04-01

    Strategic environmental assessment (SEA) has become an increasingly important decision-support tool for providing information on the environmental implications of a policy, plan, or program. The goal is to safeguard the environment and promote sustainable development at the strategic level. Despite major progress in implementing SEA practices internationally, developing countries, such as China, often lag behind in applying SEA methodology. Lack of available data and time constraints arising from tight schedules create problems. The rapid impact assessment matrix (RIAM) is a potential resource for breaking through such difficulties. Our analysis of RIAM applications suggested that it could become a tool for evaluating strategic alternatives because of its applicability in interdisciplinary settings, its transparency, and its short implementation timeframe. To make it more suitable for the SEA context, we have developed two major improvements to the conventional RIAM process: assignment of weights to assessment indicators and the development of an integrated environmental assessment score (IES). The improved RIAM process was employed in an SEA of the development plan for the Nansha District in Guangzhou, the capital city of Guangdong Province in China. It was used to assess five alternatives for development in Wanqingsha (WQS), a subunit of Nansha, where important ecological resources are located and where industrial development could impact the air quality in the neighboring Hong Kong Special Administrative Region (HKSAR). The evaluation identified WQS-A04 as the preferred alternative. This alternative involved a minimal amount of industrial development – 10% compared with the most intense development alternative – and included important wetland preservation plans. The assessment results have been incorporated into the officially approved development plan for Nansha. The improved RIAM methodology is well adapted to the technical aims of SEA and decision

  13. Applying an improved rapid impact assessment matrix method to strategic environmental assessment of urban planning in China

    International Nuclear Information System (INIS)

    Li, Wei; Xie, Yuanbo; Hao, Fanghua

    2014-01-01

    Strategic environmental assessment (SEA) has become an increasingly important decision-support tool for providing information on the environmental implications of a policy, plan, or program. The goal is to safeguard the environment and promote sustainable development at the strategic level. Despite major progress in implementing SEA practices internationally, developing countries, such as China, often lag behind in applying SEA methodology. Lack of available data and time constraints arising from tight schedules create problems. The rapid impact assessment matrix (RIAM) is a potential resource for breaking through such difficulties. Our analysis of RIAM applications suggested that it could become a tool for evaluating strategic alternatives because of its applicability in interdisciplinary settings, its transparency, and its short implementation timeframe. To make it more suitable for the SEA context, we have developed two major improvements to the conventional RIAM process: assignment of weights to assessment indicators and the development of an integrated environmental assessment score (IES). The improved RIAM process was employed in an SEA of the development plan for the Nansha District in Guangzhou, the capital city of Guangdong Province in China. It was used to assess five alternatives for development in Wanqingsha (WQS), a subunit of Nansha, where important ecological resources are located and where industrial development could impact the air quality in the neighboring Hong Kong Special Administrative Region (HKSAR). The evaluation identified WQS-A04 as the preferred alternative. This alternative involved a minimal amount of industrial development – 10% compared with the most intense development alternative – and included important wetland preservation plans. The assessment results have been incorporated into the officially approved development plan for Nansha. The improved RIAM methodology is well adapted to the technical aims of SEA and decision

  14. Transients in the Vivitron

    International Nuclear Information System (INIS)

    Cooke, C.M.; Frick, G.; Roumie, M.

    1993-01-01

    Electrical measurements are presented for the construction of a model for the study of transients in the Vivitron. Observation of the transmission of electrical pulses in the porticos clearly shows transmission-line behaviour. Measurements of the vector impedance of the outer porticos show the same transmission-line properties, but also gives a description of the modification from a pure transmission line due to the circular electrodes. The results of this investigation should allow the construction of a computer model which predicts the evolution of the transients in the case of a spark in the Vivitron. (orig.)

  15. LWR fuel performance during anticipated transients with scram

    International Nuclear Information System (INIS)

    Martinson, Z.R.; McCardell, R.K.; MacDonanl, P.E.; Rowland, T.C.; Tokar, M.

    1983-01-01

    Operational transients occur occasionally in light water reactors when minor malfunctions of certain system components affect the reactor core. Potential effects of such malfunctions include a loss of the secondary heat sink, an increase in system pressure, and, in boiling water reactors, void collapse and a brief increase in reactor power. The most severe postulated Boiling Water Reactor (BWR) anticipated transient is characterized by a power peak of up to 495% rated power for about 1 second (according to a recent General Electric Co., generic analysis). The results of a series of fuel behaviour tests in the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory are presented in this paper. Four progressively higher and broader power transients at a constant coolant flow rate were performed. The first transient simulated a BWR-5 turbine trip without steam bypass with fuel rods operating at BWR-6 core average rod powers. The second transient simulated a generator load rejection without steam bypass with fuel rods operating at above core average powers. The last two transients were performed at higher powers than safety analysis predicts to be possible in commercial reactors to be defined failure threshold margins. The test rods did not fail and were not damaged during any of the four transients. (author)

  16. Instrument response during overpower transients at TREAT

    International Nuclear Information System (INIS)

    Meek, C.C.; Bauer, T.H.; Hill, D.J.; Froehle, P.H.; Klickman, A.E.; Tylka, J.P.; Doerner, R.C.; Wright, A.E.

    1982-01-01

    A program to empirically analyze data residuals or noise to determine instrument response that occurs during in-pile transient tests is out-lined. As an example, thermocouple response in the Mark III loop during a severe overpower transient in TREAT is studied both in frequency space and in real-time. Time intervals studied included both constant power and burst portions of the power transient. Thermocouple time constants were computed. Benefits and limitations of the method are discussed

  17. Gamma-ray transients and related astrophysical phenomena

    International Nuclear Information System (INIS)

    Lingenfelter, R.E.; Hudson, H.S.; Worrall, D.M.

    1982-01-01

    The workshop covered the study of the explosive phenomena responsible for the various gamma ray transients. X-ray burster observations and theories were also reviewed with emphasis on their relationship to gamma ray bursts. Recent observational data, particularly from the SMM, HEAO, and VENERA satellites made the workshop especially timely. Major headings include: gamma-ray transients, x-ray bursts, solar transients, and instrumental concepts. Individual items from the workshop were prepared separately for the data base

  18. Simulation and analysis of a main steam line transient with isolation valves closure and subsequent pipe break

    Energy Technology Data Exchange (ETDEWEB)

    Stevanovic, Vladimir; Studovic, Milovan [Faculty of Mechanical Engineering, University of Belgrade, Belgrade (Yugoslavia); Bratic, Aleksandar [Thermal Power Plant Nikola Tesla (Yugoslavia)

    1993-11-01

    Simulation and analysis of a real main steam line break transient at the coal fired 300 MW Drmno Thermal Power Plant have been performed by the computer code TEA-01. The methods and procedures used could be applied to a nuclear power plant. 9 refs., 6 figs.

  19. Transient well flow in vertically heterogeneous aquifers

    Science.gov (United States)

    Hemker, C. J.

    1999-11-01

    A solution for the general problem of computing well flow in vertically heterogeneous aquifers is found by an integration of both analytical and numerical techniques. The radial component of flow is treated analytically; the drawdown is a continuous function of the distance to the well. The finite-difference technique is used for the vertical flow component only. The aquifer is discretized in the vertical dimension and the heterogeneous aquifer is considered to be a layered (stratified) formation with a finite number of homogeneous sublayers, where each sublayer may have different properties. The transient part of the differential equation is solved with Stehfest's algorithm, a numerical inversion technique of the Laplace transform. The well is of constant discharge and penetrates one or more of the sublayers. The effect of wellbore storage on early drawdown data is taken into account. In this way drawdowns are found for a finite number of sublayers as a continuous function of radial distance to the well and of time since the pumping started. The model is verified by comparing results with published analytical and numerical solutions for well flow in homogeneous and heterogeneous, confined and unconfined aquifers. Instantaneous and delayed drainage of water from above the water table are considered, combined with the effects of partially penetrating and finite-diameter wells. The model is applied to demonstrate that the transient effects of wellbore storage in unconfined aquifers are less pronounced than previous numerical experiments suggest. Other applications of the presented solution technique are given for partially penetrating wells in heterogeneous formations, including a demonstration of the effect of decreasing specific storage values with depth in an otherwise homogeneous aquifer. The presented solution can be a powerful tool for the analysis of drawdown from pumping tests, because hydraulic properties of layered heterogeneous aquifer systems with

  20. Twenty-five years of transient counting experience in French PWR units

    Energy Technology Data Exchange (ETDEWEB)

    Barthelet, B. [Electricite de France (EDF DPN), 93 - Saint-Denis (France); Savoldelli, D.; Fritz, R. [Electricite de France (EDF DPN), 93 - Noisy le Grand (France)

    2001-07-01

    For nearly twenty five years, EDF has been checking that the actual operating transients are neither more severe nor more numerous than the design basis transients. This activity of transient cycle counting and bookkeeping has enabled EDF to own a database of more than 800 reactor.years for the PWR units. The current method of transient cycle counting is presented. In the paper, we will point out the main results of transient cycle counting and lessons learned. In general, the frequencies of transients are lower than the design frequencies. In few cases, they are higher, such as the transient frequencies of the RCS lines connected to auxiliary systems often due to operating procedures or particular periodic testing. Few periodic tests were not taken into account in the design basis transient file ; they have been detected thanks to the transient cycle counting. In the last 1980's, we achieved the first updating of the design basis transient file for the PWR 900 MWe series. In the early 1990's, we updated the design basis transient file of the PWR 1300 MWe series. In fact, since design and start-up, the operating conditions have been modified (fuel cycle with stretch-out, modification of the hot leg and cold leg temperatures for the PWR 1300 MWe,...). This was the cause of many unclassified transients. In the new design basis transient file, we have created new transients and increased the frequencies of some of them. This has enabled to consider the updated design basis transient file more representative of actual operating transients. For some years, we have increasingly associated the operators with the transient cycle counting concern. We noticed progress (decreased frequencies of most transients). (authors)

  1. Twenty-five years of transient counting experience in French PWR units

    International Nuclear Information System (INIS)

    Barthelet, B.; Savoldelli, D.; Fritz, R.

    2001-01-01

    For nearly twenty five years, EDF has been checking that the actual operating transients are neither more severe nor more numerous than the design basis transients. This activity of transient cycle counting and bookkeeping has enabled EDF to own a database of more than 800 reactor.years for the PWR units. The current method of transient cycle counting is presented. In the paper, we will point out the main results of transient cycle counting and lessons learned. In general, the frequencies of transients are lower than the design frequencies. In few cases, they are higher, such as the transient frequencies of the RCS lines connected to auxiliary systems often due to operating procedures or particular periodic testing. Few periodic tests were not taken into account in the design basis transient file ; they have been detected thanks to the transient cycle counting. In the last 1980's, we achieved the first updating of the design basis transient file for the PWR 900 MWe series. In the early 1990's, we updated the design basis transient file of the PWR 1300 MWe series. In fact, since design and start-up, the operating conditions have been modified (fuel cycle with stretch-out, modification of the hot leg and cold leg temperatures for the PWR 1300 MWe,...). This was the cause of many unclassified transients. In the new design basis transient file, we have created new transients and increased the frequencies of some of them. This has enabled to consider the updated design basis transient file more representative of actual operating transients. For some years, we have increasingly associated the operators with the transient cycle counting concern. We noticed progress (decreased frequencies of most transients). (authors)

  2. Effects of rapid shortening on rate of force regeneration and myoplasmic [Ca2+] in intact frog skeletal muscle fibres

    Science.gov (United States)

    Vandenboom, R; Claflin, D R; Julian, F J

    1998-01-01

    The effect of rapid shortening on rate of force regeneration (dF/dtR) was examined in single, intact frog (Rana temporaria) skeletal muscle fibres (3·0 °C). Step releases leading to unloaded shortening were applied after 500 ms of stimulation, during the plateau of an isometric tetanus. Initial mean sarcomere length ranged from 2·05 to 2·35 μm; force regeneration after shortening was at 2·00 μm.Values for dF/dtR following a 25 nm half-sarcomere−1 release were 3·17 ± 0·17 (mean ± s.e.m., n= 8) times greater than the initial rate of rise of force before release (dF/dtI). As release size was increased from 25 to 175 nm half-sarcomere−1, the relationship between release size and dF/dtR decreased sharply before attaining a plateau value that was 1·34 ± 0·09 times greater than dF/dtI. Despite wide variations in dF/dtR, the velocity of unloaded shortening remained constant (2·92 ± 0·08 μm half-sarcomere−1 s−1; n= 8) for the different release amplitudes used in this study.To investigate its role in the attenuation of dF/dtR with increased shortening, the effects of rapid ramp (constant velocity) shortening on intracellular free Ca2+ concentration ([Ca2+]i) were monitored using the Ca2+-sensitive fluorescent dye furaptra. Compared with an isometric contraction, rapid fibre shortening was associated with a transient increase in [Ca2+]i while force regeneration after shortening was associated with a transient reduction in [Ca2+]i. The greatest reductions in [Ca2+]i were associated with the largest amplitude ramps.Cross-bridge-mediated modifications of the Ca2+ affinity of troponin C (TnC) may explain the fluctuations in [Ca2+]i observed during and after ramps. Associated fluctuations in TnC Ca2+ occupancy could play a role in the reduction of dF/dtR with increasing release size. PMID:9679172

  3. Loss of integrated control system power and overcooling transient at Rancho Seco on December 26, 1985

    International Nuclear Information System (INIS)

    1986-02-01

    On December 26, 1985, Rancho Seco Nuclear Generating Station, located in Clay, California, about 25 miles southeast of Sacramento, experienced a loss of dc power within the integrated control system (ICS) while the plant was operating at 76% power. The plant is owned by the Sacramento Municipal Utility District (SMUD). Following the loss of ICS dc power, the reactor tripped on high reactor coolant system (RCS) pressure followed by a rapid overcooling transient and automatic initiation of the safety features actuation system on low RCS pressure. The overcooling transient continued until ICS dc power was restored 26 minutes after its loss. The fundamental causes for this transient were design weaknesses and vulnerabilities in the ICS and in the equipment controlled by that system. These weaknesses and vulnerabilities were not adequately compensated by other design features, plant procedures or operator training. These weaknesses and vulnerabilities were largely known to SMUD and the NRC staff by virtue of a number of precursor events and through related analyses and studies. Yet, adequate plant modifications were not made so that this event would be improbable, or so that its course or consequences would be altered significantly. The information was available and known which could have prevented this overcooling transient; but in the absence of adequate plant modifications, the incident should have been expected. The report includes findings and conclusions of the NRC Incident Investigation Team sent to Rancho Seco by the NRC Executive Director for Operations in conformance with NRC's recently established Incident Investigation Program. 33 figs

  4. Steady-state pattern electroretinogram and short-duration transient visual evoked potentials in glaucomatous and healthy eyes.

    Science.gov (United States)

    Amarasekera, Dilru C; Resende, Arthur F; Waisbourd, Michael; Puri, Sanjeev; Moster, Marlene R; Hark, Lisa A; Katz, L Jay; Fudemberg, Scott J; Mantravadi, Anand V

    2018-01-01

    This study evaluates two rapid electrophysiological glaucoma diagnostic tests that may add a functional perspective to glaucoma diagnosis. This study aimed to determine the ability of two office-based electrophysiological diagnostic tests, steady-state pattern electroretinogram and short-duration transient visual evoked potentials, to discern between glaucomatous and healthy eyes. This is a cross-sectional study in a hospital setting. Forty-one patients with glaucoma and 41 healthy volunteers participated in the study. Steady-state pattern electroretinogram and short-duration transient visual evoked potential testing was conducted in glaucomatous and healthy eyes. A 64-bar-size stimulus with both a low-contrast and high-contrast setting was used to compare steady-state pattern electroretinogram parameters in both groups. A low-contrast and high-contrast checkerboard stimulus was used to measure short-duration transient visual evoked potential parameters in both groups. Steady-state pattern electroretinogram parameters compared were MagnitudeD, MagnitudeD/Magnitude ratio, and the signal-to-noise ratio. Short-duration transient visual evoked potential parameters compared were amplitude and latency. MagnitudeD was significantly lower in glaucoma patients when using a low-contrast (P = 0.001) and high-contrast (P state pattern electroretinogram stimulus. MagnitudeD/Magnitude ratio and SNR were significantly lower in the glaucoma group when using a high-contrast 64-bar-size stimulus (P state pattern electroretinogram was effectively able to discern between glaucomatous and healthy eyes. Steady-state pattern electroretinogram may thus have a role as a clinically useful electrophysiological diagnostic tool. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  5. The effect of a transient thermal lens on the Nd:YVO4 laser output

    International Nuclear Information System (INIS)

    Yi, Jonghoon; Lee, Kangin; Kim, Youngjung; Kwon, Jinhyuk

    2010-01-01

    A Nd:YVO 4 laser was pumped by using a diode laser, which has maximum cw pump power of 1 W. The driving current of the diode laser was modulated to have a square waveform. The Nd:YVO 4 laser output power increased linearly and then saturated when the quasi-cw diode laser pulse was focused on the crystal. When the same diode laser pulse was applied on the crystal, transient thermal lensing in the Nd:YVO 4 crystal was monitored by using a probe beam in a non-lasing condition. The TEM 00 mode diameter of the laser was calculated as a function of the focal length of the thermal lens. The results indicated that transient thermal lensing in the crystal was the main cause of the temporally varying output.

  6. COMETHE III-M for transient fuel rod behaviour prediction

    International Nuclear Information System (INIS)

    Billaux, M.; Vliet, J. van

    1983-01-01

    The COMETHE III-M version is being developed in order to provide fuel rod behaviour prediction capability both in steady-state and in transient situations. It also allows to estimate the fuel rod enthalpy evolution versus time or burnup which may be important in core-related safety studies. This paper describes the transient heat transfer models, including transient heat conduction inside the fuel rod, and a subchannel model providing transient flow as well as enthalpy calculation capability. Transient fission gas release is also modelled on basis of the change rate of oxide temperature. The models are illustrated by a few calculation examples. (author)

  7. Transient toxicity of 2-Deoxy-2-[18F] fluoro-D-Glucose in mammalian cells: concise communication

    International Nuclear Information System (INIS)

    Kassis, A.I.; Adelstein, S.J.; Wolf, A.P.; Fowler, J.G.; Shiue, C.Y.

    1983-01-01

    The kinetics of uptake and toxicity of the positron emitter F-18 have been examined in a cultured cell line. 2-Deoxy-2[ 18 F]fluoro-D-glucose ( 18 FDG) concentrated rapidly within Chinese hamster V79 cells, and the uptake was linear with the extracellular radioactive concentrations. Whereas 18 FDG sythesized 2 hr before the incubation did not appear to be toxic, that synthesized 5 hr previously was highly toxic. Toxicity was transient and independent of both the extracellular/intracellular radioactive concentration and the energy released from the decay of fluorine-18. Similarly synthesized nonradioactive FDG and Na 18 F were not toxic under comparable experimental conditions. The authors conclude that this transient toxicity is due to an unidentified chemical species that is cytocidal following intracellular localization. These toxic levels are not likely to be achieved in the clinical use of 18 FDG due to dilution factors that are orders of magnitude greater than those used in these in vitro studies

  8. Search for Transient Gravitational Waves in Coincidence with Short-Duration Radio Transients During 2007-2013

    Science.gov (United States)

    Abbott, B. P.; Hughey, Brennan; Zanolin, Michele; Szczepanczyk, Marek; Gill, Kiranjyot; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; hide

    2016-01-01

    We present an archival search for transient gravitational-wave bursts in coincidence with 27 single-pulse triggers from Green Bank Telescope pulsar surveys, using the LIGO (Laser Interferometer Gravitational Wave Observatory), Virgo (Variability of Solar Irradiance and Gravity Oscillations) and GEO (German-UK Interferometric Detector) interferometer network. We also discuss a check for gravitational-wave signals in coincidence with Parkes fast radio bursts using similar methods. Data analyzed in these searches were collected between 2007 and 2013. Possible sources of emission of both short-duration radio signals and transient gravitational-wave emission include star quakes on neutron stars, binary coalescence of neutron stars, and cosmic string cusps. While no evidence for gravitational-wave emission in coincidence with these radio transients was found, the current analysis serves as a prototype for similar future searches using more sensitive second-generation interferometers.

  9. New developments in French transient monitoring: SYSFAC

    International Nuclear Information System (INIS)

    L'huby, Y.; Genette, P.; Faidy, C.; Kappler, F.; Balley, J.; Bimont, G.

    1991-01-01

    After more than ten years of experience with Transient Monitoring and Logging Procedure (TMLP) and six years of successfully experience with Fatiguemeters, EDF has decided to study a new concept of Fatigue Monitoring System: SYSFAC. This new automatic system which is developed to be operating in all the French PWR units is composed of three modules: mechanical transient logging, functional transient logging and fatiguemeters. This application must be connected to the on-site data acquisition system without complementary instrumentation on the plant. (author)

  10. Transient Beam Dynamics in the LBL 2 MV Injector

    International Nuclear Information System (INIS)

    Henestroza, E; Grote, D

    1999-01-01

    A driver-scale injector for the Heavy Ion Fusion Accelerator project has been built at LBL. This machine has exceeded the design goals of high voltage (> 2 MV), high current (> 0.8 A of K + ) and low normalized emittance (< 1 π mm-mr). The injector consists of a 750 keV gun pre-injector followed by an electrostatic quadrupole accelerator (ESQ) which provides strong (alternating gradient) focusing for the space-charge dominated beam, and simultaneously accelerates the ions to 2 MeV. A matching section is being built to match the beam to the electrostatic accelerator ELISE. The gun preinjector, designed to hold up to 1 MV with minimal breakdown risks, consists of a hot aluminosilicate source with a large curved emitting surface surrounded by a thick ''extraction electrode''. During beam turn-on the voltage at the source is biased from a negative potential, enough to reverse the electric field on the emitting surface and avoid emission, to a positive potential to start extracting the beam; it stays constant for about 1 (micro)s, and is reversed to turn-off the emission. Since the Marx voltage applied on the accelerating quadrupoles and the main pre-injector gap is a long, constant pulse (several (micro)s), the transient behavior is dominated by the extraction pulser voltage time profile. The transient longitudinal dynamics of the beam in the injector was simulated by running the Particle in Cell codes GYMNOS and WARP3d in a time dependent mode. The generalization and its implementation in WAIW3d of a method proposed by Lampel and Tiefenback to eliminate transient oscillations in a one-dimensional planar diode will be presented

  11. Transient analysis of a queue with queue-length dependent MAP and its application to SS7 network

    Directory of Open Access Journals (Sweden)

    Bong Dae Choi

    1999-01-01

    Full Text Available We analyze the transient behavior of a Markovian arrival queue with congestion control based on a double of thresholds, where the arrival process is a queue-length dependent Markovian arrival process. We consider Markov chain embedded at arrival epochs and derive the one-step transition probabilities. From these results, we obtain the mean delay and the loss probability of the nth arrival packet. Before we study this complex model, first we give a transient analysis of an MAP/M/1 queueing system without congestion control at arrival epochs. We apply our result to a signaling system No. 7 network with a congestion control based on thresholds.

  12. Climatic feedbacks between stationary and transient eddies

    International Nuclear Information System (INIS)

    Branscome, L.E.

    1994-01-01

    Stationary eddies make a significant contribution to poleward heat transport during Northern Hemisphere winter, equaling the transport by transient eddies. On the other hand, stationary eddy transport during the summer is negligible. The effect of topography on time-mean stationary waves and low-frequency variability has been widely studied. In contrast, little attention has been given to the climatic feedbacks associated with stationary eddies. Furthermore, the relationship between stationary and transient eddies in the context of global and regional climate is not well understood. The response of the climate system to anthropogenic forcing is likely to have some dependence on stationary wave transport and its interaction with transient eddies. Some early GCM simulations and observational analyses indicate a strong feedback between the meridional heat fluxes of stationary and transient eddies

  13. Core-Collapse Supernova Progenitors In The Era Of Untargeted Transient Searches

    Science.gov (United States)

    Sanders, Nathan Edward

    2014-04-01

    Core-collapse supernovae (SNe) are the highly energetic explosions of massive stars (≳ 8 M⊙) that are pervasive in their influence throughout astrophysics. They are the phenomenon with primary responsibility for enriching the universe with many of the heavy elements (like carbon and oxygen) that are needed for life, provide a critical feedback pressure which helps to shape the galaxies that host them, and are the likely formation mechanism for stellar mass black holes. In the past decade, the study of these explosions has been revolutionized by the advent of wide field, untargeted transient searches like Pan-STARRS1 (PS1). These new searches permit the discovery of SNe at unprecedented rates, and absent of many of the selection effects that have enforced biases on past, targeted transient searches. This thesis presents a broad survey of core-collapse SN phenomenology exhibited in the discoveries of untargeted searches, and statistically quantifies population properties of these explosions that link them to distinct classes of progenitor stars. Through studies of the host galaxy and explosion properties of extreme PS1-discovered events, and controlled samples of specific classes of core-collapse objects, we constrain the effect of progenitor star chemical composition (metallicity) on their eventual death states. We provide a new observational, photometric tool which lowers the cost of precisely and accurately measuring the metallicities of distant galaxies and supernova host environments. Moreover, we develop and apply a novel, multi-level Bayesian model for optical transient light curves which we apply to simultaneously interpret more than 20,000 PS1 images. This study illustrates how population-level modeling of data from large photometric surveys can yield improved physical inference on their progenitor stars through comparison to physical models. In the coming era, as next-generation facilities like the Large Synoptic Survey Telescope come online, the

  14. Rapid solidification for preparation of high Tc superconductors

    International Nuclear Information System (INIS)

    Yavari, A.R.

    1988-01-01

    High Tc superconducting oxides are prepared in two different ways using rapid solidification: by oxidation of microcrystalline or amorphous tapes obtained by quenching the liquid alloy and via crystallisation of the amorphous oxide obtained by rapid quenching of the oxide melt. This technique is applied for the first time to the BiCaSrCuO family [fr

  15. Transient Seepage for Levee Engineering Analyses

    Science.gov (United States)

    Tracy, F. T.

    2017-12-01

    Historically, steady-state seepage analyses have been a key tool for designing levees by practicing engineers. However, with the advances in computer modeling, transient seepage analysis has become a potentially viable tool. A complication is that the levees usually have partially saturated flow, and this is significantly more complicated in transient flow. This poster illustrates four elements of our research in partially saturated flow relating to the use of transient seepage for levee design: (1) a comparison of results from SEEP2D, SEEP/W, and SLIDE for a generic levee cross section common to the southeastern United States; (2) the results of a sensitivity study of varying saturated hydraulic conductivity, the volumetric water content function (as represented by van Genuchten), and volumetric compressibility; (3) a comparison of when soils do and do not exhibit hysteresis, and (4) a description of proper and improper use of transient seepage in levee design. The variables considered for the sensitivity and hysteresis studies are pore pressure beneath the confining layer at the toe, the flow rate through the levee system, and a levee saturation coefficient varying between 0 and 1. Getting results for SEEP2D, SEEP/W, and SLIDE to match proved more difficult than expected. After some effort, the results matched reasonably well. Differences in results were caused by various factors, including bugs, different finite element meshes, different numerical formulations of the system of nonlinear equations to be solved, and differences in convergence criteria. Varying volumetric compressibility affected the above test variables the most. The levee saturation coefficient was most affected by the use of hysteresis. The improper use of pore pressures from a transient finite element seepage solution imported into a slope stability computation was found to be the most grievous mistake in using transient seepage in the design of levees.

  16. Transient voltage oscillations in coils

    International Nuclear Information System (INIS)

    Chowdhuri, P.

    1985-01-01

    Magnet coils may be excited into internal voltage oscillations by transient voltages. Such oscillations may electrically stress the magnet's dielectric components to many times its normal stress. This may precipitate a dielectric failure, and the attendant prolonged loss of service and costly repair work. Therefore, it is important to know the natural frequencies of oscillations of a magnet during the design stage, and to determine whether the expected switching transient voltages can excite the magnet into high-voltage internal oscillations. The series capacitance of a winding significantly affects its natural frequencies. However, the series capacitance is difficult to calculate, because it may comprise complex capacitance network, consisting of intra- and inter-coil turn-to-turn capacitances of the coil sections. A method of calculating the series capacitance of a winding is proposed. This method is rigorous but simple to execute. The time-varying transient voltages along the winding are also calculated

  17. Interpreting signals from astrophysical transient experiments.

    Science.gov (United States)

    O'Brien, Paul T; Smartt, Stephen J

    2013-06-13

    Time-domain astronomy has come of age with astronomers now able to monitor the sky at high cadence, both across the electromagnetic spectrum and using neutrinos and gravitational waves. The advent of new observing facilities permits new science, but the ever-increasing throughput of facilities demands efficient communication of coincident detections and better subsequent coordination among the scientific community so as to turn detections into scientific discoveries. To discuss the revolution occurring in our ability to monitor the Universe and the challenges it brings, on 25-26 April 2012, a group of scientists from observational and theoretical teams studying transients met with representatives of the major international transient observing facilities at the Kavli Royal Society International Centre, UK. This immediately followed the Royal Society Discussion Meeting 'New windows on transients across the Universe' held in London. Here, we present a summary of the Kavli meeting at which the participants discussed the science goals common to the transient astronomy community and analysed how to better meet the challenges ahead as ever more powerful observational facilities come on stream.

  18. RETRAN sensitivity studies of light water reactor transients. Final report

    International Nuclear Information System (INIS)

    Burrell, N.S.; Gose, G.C.; Harrison, J.F.; Sawtelle, G.R.

    1977-06-01

    This report presents the results of sensitivity studies performed using the RETRAN/RELAP4 transient analysis code to identify critical parameters and models which influence light water reactor transient predictions. Various plant transients for both boiling water reactors and pressurized water reactors are examined. These studies represent the first detailed evaluation of the RETRAN/RELAP4 transient code capability in predicting a variety of plant transient responses. The wide range of transients analyzed in conjunction with the parameter and modeling studies performed identify several sensitive areas as well as areas requiring future study and model development

  19. Models for Type Ia Supernovae and Related Astrophysical Transients

    Science.gov (United States)

    Röpke, Friedrich K.; Sim, Stuart A.

    2018-06-01

    We give an overview of recent efforts to model Type Ia supernovae and related astrophysical transients resulting from thermonuclear explosions in white dwarfs. In particular we point out the challenges resulting from the multi-physics multi-scale nature of the problem and discuss possible numerical approaches to meet them in hydrodynamical explosion simulations and radiative transfer modeling. We give examples of how these methods are applied to several explosion scenarios that have been proposed to explain distinct subsets or, in some cases, the majority of the observed events. In case we comment on some of the successes and shortcoming of these scenarios and highlight important outstanding issues.

  20. Timing of transients: quantifying reaching times and transient behavior in complex systems

    Science.gov (United States)

    Kittel, Tim; Heitzig, Jobst; Webster, Kevin; Kurths, Jürgen

    2017-08-01

    In dynamical systems, one may ask how long it takes for a trajectory to reach the attractor, i.e. how long it spends in the transient phase. Although for a single trajectory the mathematically precise answer may be infinity, it still makes sense to compare different trajectories and quantify which of them approaches the attractor earlier. In this article, we categorize several problems of quantifying such transient times. To treat them, we propose two metrics, area under distance curve and regularized reaching time, that capture two complementary aspects of transient dynamics. The first, area under distance curve, is the distance of the trajectory to the attractor integrated over time. It measures which trajectories are ‘reluctant’, i.e. stay distant from the attractor for long, or ‘eager’ to approach it right away. Regularized reaching time, on the other hand, quantifies the additional time (positive or negative) that a trajectory starting at a chosen initial condition needs to approach the attractor as compared to some reference trajectory. A positive or negative value means that it approaches the attractor by this much ‘earlier’ or ‘later’ than the reference, respectively. We demonstrated their substantial potential for application with multiple paradigmatic examples uncovering new features.

  1. Clan structure analysis and rapidity gap probability

    International Nuclear Information System (INIS)

    Lupia, S.; Giovannini, A.; Ugoccioni, R.

    1995-01-01

    Clan structure analysis in rapidity intervals is generalized from negative binomial multiplicity distribution to the wide class of compound Poisson distributions. The link of generalized clan structure analysis with correlation functions is also established. These theoretical results are then applied to minimum bias events and evidentiate new interesting features, which can be inspiring and useful in order to discuss data on rapidity gap probability at TEVATRON and HERA. (orig.)

  2. Clan structure analysis and rapidity gap probability

    Energy Technology Data Exchange (ETDEWEB)

    Lupia, S. [Turin Univ. (Italy). Ist. di Fisica Teorica]|[Istituto Nazionale di Fisica Nucleare, Turin (Italy); Giovannini, A. [Turin Univ. (Italy). Ist. di Fisica Teorica]|[Istituto Nazionale di Fisica Nucleare, Turin (Italy); Ugoccioni, R. [Turin Univ. (Italy). Ist. di Fisica Teorica]|[Istituto Nazionale di Fisica Nucleare, Turin (Italy)

    1995-03-01

    Clan structure analysis in rapidity intervals is generalized from negative binomial multiplicity distribution to the wide class of compound Poisson distributions. The link of generalized clan structure analysis with correlation functions is also established. These theoretical results are then applied to minimum bias events and evidentiate new interesting features, which can be inspiring and useful in order to discuss data on rapidity gap probability at TEVATRON and HERA. (orig.)

  3. Hole traps in n-GaN detected by minority carrier transient spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tokuda, Yutaka; Yamada, Yujiro; Shibata, Tatsunari; Yamaguchi, Shintaro [Department of Electrical and Electronics Engineering, Aichi Institute of Technology, Yakusa, 470-0392 Toyota (Japan); Ueda, Hiroyuki; Uesugi, Tsutomu; Kachi, Tetsu [Toyota Central R and D Laboratories, Inc., Nagakute, 480-1192 Aichi (Japan)

    2011-07-15

    Minority carrier transient spectroscopy (MCTS) has been applied for the detection of hole traps in n-GaN using Schottky diodes. MCTS using 355 nm light emitting diodes is performed under isothermal conditions in the temperature range 280 to 330 K for n-GaN grown by metalorganic chemical vapor deposition on sapphire. Isothermal MCTS spectra reveal the E{sub v} + 0.86 eV hole trap with the trap concentration of 1.1x10{sup 16} cm{sup -3}. The E{sub v} + 0.86 eV hole trap has the higher concentration as compared to electron traps observed by deep level transient spectroscopy. Thus, the isothermal MCTS around room temperature provides a convenient way to evaluate the dominant trap in n-GaN. It is suggested that the E{sub v} + 0.86 eV hole trap is associated with the V{sub Ga}-related defect or carbon-related defect. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Fuel-pin cladding transient failure strain criterion

    International Nuclear Information System (INIS)

    Bard, F.E.; Duncan, D.R.; Hunter, C.W.

    1983-01-01

    A criterion for cladding failure based on accumulated strain was developed for mixed uranium-plutonium oxide fuel pins and used to interpret the calculated strain results from failed transient fuel pin experiments conducted in the Transient Reactor Test (TREAT) facility. The new STRAIN criterion replaced a stress-based criterion that depends on the DORN parameter and that incorrectly predicted fuel pin failure for transient tested fuel pins. This paper describes the STRAIN criterion and compares its prediction with those of the stress-based criterion

  5. A polycystin-type transient receptor potential (Trp channel that is activated by ATP

    Directory of Open Access Journals (Sweden)

    David Traynor

    2017-02-01

    Full Text Available ATP and ADP are ancient extra-cellular signalling molecules that in Dictyostelium amoebae cause rapid, transient increases in cytosolic calcium due to an influx through the plasma membrane. This response is independent of hetero-trimeric G-proteins, the putative IP3 receptor IplA and all P2X channels. We show, unexpectedly, that it is abolished in mutants of the polycystin-type transient receptor potential channel, TrpP. Responses to the chemoattractants cyclic-AMP and folic acid are unaffected in TrpP mutants. We report that the DIF morphogens, cyclic-di-GMP, GABA, glutamate and adenosine all induce strong cytoplasmic calcium responses, likewise independently of TrpP. Thus, TrpP is dedicated to purinergic signalling. ATP treatment causes cell blebbing within seconds but this does not require TrpP, implicating a separate purinergic receptor. We could detect no effect of ATP on chemotaxis and TrpP mutants grow, chemotax and develop almost normally in standard conditions. No gating ligand is known for the human homologue of TrpP, polycystin-2, which causes polycystic kidney disease. Our results now show that TrpP mediates purinergic signalling in Dictyostelium and is directly or indirectly gated by ATP.

  6. Transient hardened power FETs

    International Nuclear Information System (INIS)

    Dawes, W.R. Jr.; Fischer, T.A.; Huang, C.C.C.; Meyer, W.J.; Smith, C.S.; Blanchard, R.A.; Fortier, T.J.

    1986-01-01

    N-channel power FETs offer significant advantages in power conditioning circuits. Similiarily to all MOS technologies, power FET devices are vulnerable to ionizing radiation, and are particularily susceptible to burn-out in high dose rate irradiations (>1E10 rads(Si)/sec.), which precludes their use in many military environments. This paper will summarize the physical mechanisms responsible for burn-out, and discuss various fabrication techniques designed to improve the transient hardness of power FETs. Power FET devices were fabricated with several of these techniques, and data will be presented which demonstrates that transient hardness levels in excess of 1E12 rads(Si)/sec. are easily achievable

  7. Imaging findings and referral outcomes of rapid assessment stroke clinics

    International Nuclear Information System (INIS)

    Widjaja, E.; Manuel, D.; Hodgson, T.J.; Connolly, D.J.A.; Coley, S.C.; Romanowski, C.A.J.; Gaines, P.; Cleveland, T.; Thomas, S.; Griffiths, P.D.; Doyle, C.; Venables, G.S.

    2005-01-01

    AIM: A rapid assessment stroke clinic (RASC) was established to provide a rapid diagnostic service to individuals with suspected transient cerebral or ocular ischaemia or recovered non-hospitalized strokes. In this report we review imaging findings and clinical outcomes of patients proceeding to the carotid surgery programme. METHODS: Between October 2000 and December 2002, 1339 people attended the RASC. The findings of head CT and carotid Doppler ultrasound of the 1320 patients who underwent brain and carotid imaging were reviewed, and the number subsequently proceeding to carotid angiography and intervention was reported. RESULTS: CT head scans were normal in 57% of cases; 38% demonstrated ischaemia or infarction; and 3% yielded incidental or other significant findings not related to ischaemia. On screening with carotid Doppler ultrasound, 7.5% showed greater than 50% stenosis on the symptomatic side. A total of 83 patients (6.2%) proceeded to cerebral angiography and 65 (4.8%) underwent carotid endarterectomy or endovascular repair. CONCLUSION: Rapid-access neurovascular clinics are efficient in selecting patients for carotid intervention, but this is at a cost and the number of potential strokes prevented is small. Alternative management pathways based on immediate medical treatment need to be evaluated

  8. Efficient production of antibody Fab fragment by transient gene expression in insect cells.

    Science.gov (United States)

    Mori, Keita; Hamada, Hirotsugu; Ogawa, Takafumi; Ohmuro-Matsuyama, Yuki; Katsuda, Tomohisa; Yamaji, Hideki

    2017-08-01

    Transient gene expression allows a rapid production of diverse recombinant proteins in early-stage preclinical and clinical developments of biologics. Insect cells have proven to be an excellent platform for the production of functional recombinant proteins. In the present study, the production of an antibody Fab fragment by transient gene expression in lepidopteran insect cells was investigated. The DNA fragments encoding heavy-chain (Hc; Fd fragment) and light-chain (Lc) genes of an Fab fragment were individually cloned into the plasmid vector pIHAneo, which contained the Bombyx mori actin promoter downstream of the B. mori nucleopolyhedrovirus (BmNPV) IE-1 transactivator and the BmNPV HR3 enhancer for high-level expression. Trichoplusia ni BTI-TN-5B1-4 (High Five) cells were co-transfected with the resultant plasmid vectors using linear polyethyleneimine. When the transfection efficiency was evaluated, a plasmid vector encoding an enhanced green fluorescent protein (EGFP) gene was also co-transfected. Transfection and culture conditions were optimized based on both the flow cytometry of the EGFP expression in transfected cells and the yield of the secreted Fab fragments determined by enzyme-linked immunosorbent assay (ELISA). Under optimal conditions, a yield of approximately 120 mg/L of Fab fragments was achieved in 5 days in a shake-flask culture. Transient gene expression in insect cells may offer a promising approach to the high-throughput production of recombinant proteins. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  9. Four RNA families with functional transient structures.

    Science.gov (United States)

    Zhu, Jing Yun A; Meyer, Irmtraud M

    2015-01-01

    Protein-coding and non-coding RNA transcripts perform a wide variety of cellular functions in diverse organisms. Several of their functional roles are expressed and modulated via RNA structure. A given transcript, however, can have more than a single functional RNA structure throughout its life, a fact which has been previously overlooked. Transient RNA structures, for example, are only present during specific time intervals and cellular conditions. We here introduce four RNA families with transient RNA structures that play distinct and diverse functional roles. Moreover, we show that these transient RNA structures are structurally well-defined and evolutionarily conserved. Since Rfam annotates one structure for each family, there is either no annotation for these transient structures or no such family. Thus, our alignments either significantly update and extend the existing Rfam families or introduce a new RNA family to Rfam. For each of the four RNA families, we compile a multiple-sequence alignment based on experimentally verified transient and dominant (dominant in terms of either the thermodynamic stability and/or attention received so far) RNA secondary structures using a combination of automated search via covariance model and manual curation. The first alignment is the Trp operon leader which regulates the operon transcription in response to tryptophan abundance through alternative structures. The second alignment is the HDV ribozyme which we extend to the 5' flanking sequence. This flanking sequence is involved in the regulation of the transcript's self-cleavage activity. The third alignment is the 5' UTR of the maturation protein from Levivirus which contains a transient structure that temporarily postpones the formation of the final inhibitory structure to allow translation of maturation protein. The fourth and last alignment is the SAM riboswitch which regulates the downstream gene expression by assuming alternative structures upon binding of SAM. All

  10. Congestion management enhancing transient stability of power systems

    International Nuclear Information System (INIS)

    Esmaili, Masoud; Shayanfar, Heidar Ali; Amjady, Nima

    2010-01-01

    In a competitive electricity market, where market parties try to maximize their profits, it is necessary to keep an acceptable level of power system security to retain the continuity of electricity services to customers at a reasonable cost. Congestion in a power system is turned up due to network limits. After relieving congestion, the network may be operated with a reduced transient stability margin because of increasing the contribution of risky participants. In this paper, a novel congestion management method based on a new transient stability criterion is introduced. Using the sensitivity of corrected transient stability margin with respect to generations and demands, the proposed method so alleviates the congestion that the network can more retain its transient security compared with earlier methods. The proposed transient stability index is constructed considering the likelihood of credible faults. Indeed, market parties participate by their security-effective bids rather than raw bids. Results of testing the proposed method along with the earlier ones on the New-England test system elaborate the efficiency of the proposed method from the viewpoint of providing a better transient stability margin with a lower security cost. (author)

  11. Positron deep level transient spectroscopy — a new application of positron annihilation to semiconductor physics

    Science.gov (United States)

    Beling, C. D.; Fung, S.; Au, H. L.; Ling, C. C.; Reddy, C. V.; Deng, A. H.; Panda, B. K.

    1997-05-01

    Recent positron mobility and lifetime measurements made on ac-biased metal on semi-insulating GaAs junctions, which have identified the native EL2 defect through a determination of the characteristic ionization energy of the donor level, are reviewed. It is shown that these measurements point towards a new spectroscopy, tentatively named positron-DLTS (deep level transient spectroscopy), that is the direct complement to conventional DLTS in that it monitors transients in the electric field of the depletion region rather than the inversely related depletion width, as deep levels undergo ionization. In this new spectroscopy, which may be applied to doped material by use of a suitable positron beam, electric field transients are monitored through the Doppler shift of the annihilation radiation resulting from the drift velocity of the positron in the depletion region. Two useful extensions of the new spectroscopy beyond conventional capacitance-DLTS are suggested. The first is that in some instances information on the microstructure of the defect causing the deep level may be inferred from the sensitivity of the positron to vacancy defects of negative and neutral charge states. The second is that the positron annihilation technique is intrinsically much faster than conventional DLTS with the capability of observing transients some 10 6 times faster, thus allowing deep levels (and even shallow levels) to be investigated without problems associated with carrier freeze-out.

  12. Reducing Conservatism of Analytic Transient Response Bounds via Shaping Filters

    Science.gov (United States)

    Kwan, Aiyueh; Bedrossian, Nazareth; Jan, Jiann-Woei; Grigoriadis, Karolos; Hua, Tuyen (Technical Monitor)

    1999-01-01

    Recent results show that the peak transient response of a linear system to bounded energy inputs can be computed using the energy-to-peak gain of the system. However, analytically computed peak response bound can be conservative for a class of class bounded energy signals, specifically pulse trains generated from jet firings encountered in space vehicles. In this paper, shaping filters are proposed as a Methodology to reduce the conservatism of peak response analytic bounds. This Methodology was applied to a realistic Space Station assembly operation subject to jet firings. The results indicate that shaping filters indeed reduce the predicted peak response bounds.

  13. Transient formation of forbidden lines

    International Nuclear Information System (INIS)

    Rosmej, F.B.; Rosmej, O.N.

    1996-01-01

    An explanation of anomalously long time scales in the transient formation of forbidden lines is proposed. The concept is based on a collisionally induced density dependence of the relaxation times of metastable level populations in transient plasma. Generalization leads to an incorporation of diffusion phenomena. We demonstrate this new concept for the simplest atomic system: the He-like isoelectronic sequence. A new interpretation of the observed long duration and anomalously high intensity of spin-forbidden emission in hot plasmas is given. (author)

  14. Transient formation of forbidden lines

    Energy Technology Data Exchange (ETDEWEB)

    Rosmej, F.B. [Bochum Univ., Ruhr (Germany). Inst. fuer Experimentalphysik V; Rosmej, O.N. [VNIIFTRI, Moscow Region (Russian Federation). MISDC

    1996-05-14

    An explanation of anomalously long time scales in the transient formation of forbidden lines is proposed. The concept is based on a collisionally induced density dependence of the relaxation times of metastable level populations in transient plasma. Generalization leads to an incorporation of diffusion phenomena. We demonstrate this new concept for the simplest atomic system: the He-like isoelectronic sequence. A new interpretation of the observed long duration and anomalously high intensity of spin-forbidden emission in hot plasmas is given. (author).

  15. The stretch to stray on time: Resonant length of random walks in a transient

    Science.gov (United States)

    Falcke, Martin; Friedhoff, Victor Nicolai

    2018-05-01

    First-passage times in random walks have a vast number of diverse applications in physics, chemistry, biology, and finance. In general, environmental conditions for a stochastic process are not constant on the time scale of the average first-passage time or control might be applied to reduce noise. We investigate moments of the first-passage time distribution under an exponential transient describing relaxation of environmental conditions. We solve the Laplace-transformed (generalized) master equation analytically using a novel method that is applicable to general state schemes. The first-passage time from one end to the other of a linear chain of states is our application for the solutions. The dependence of its average on the relaxation rate obeys a power law for slow transients. The exponent ν depends on the chain length N like ν = - N / ( N + 1 ) to leading order. Slow transients substantially reduce the noise of first-passage times expressed as the coefficient of variation (CV), even if the average first-passage time is much longer than the transient. The CV has a pronounced minimum for some lengths, which we call resonant lengths. These results also suggest a simple and efficient noise control strategy and are closely related to the timing of repetitive excitations, coherence resonance, and information transmission by noisy excitable systems. A resonant number of steps from the inhibited state to the excitation threshold and slow recovery from negative feedback provide optimal timing noise reduction and information transmission.

  16. Phase-amplitude reduction of transient dynamics far from attractors for limit-cycling systems

    Science.gov (United States)

    Shirasaka, Sho; Kurebayashi, Wataru; Nakao, Hiroya

    2017-02-01

    Phase reduction framework for limit-cycling systems based on isochrons has been used as a powerful tool for analyzing the rhythmic phenomena. Recently, the notion of isostables, which complements the isochrons by characterizing amplitudes of the system state, i.e., deviations from the limit-cycle attractor, has been introduced to describe the transient dynamics around the limit cycle [Wilson and Moehlis, Phys. Rev. E 94, 052213 (2016)]. In this study, we introduce a framework for a reduced phase-amplitude description of transient dynamics of stable limit-cycling systems. In contrast to the preceding study, the isostables are treated in a fully consistent way with the Koopman operator analysis, which enables us to avoid discontinuities of the isostables and to apply the framework to system states far from the limit cycle. We also propose a new, convenient bi-orthogonalization method to obtain the response functions of the amplitudes, which can be interpreted as an extension of the adjoint covariant Lyapunov vector to transient dynamics in limit-cycling systems. We illustrate the utility of the proposed reduction framework by estimating the optimal injection timing of external input that efficiently suppresses deviations of the system state from the limit cycle in a model of a biochemical oscillator.

  17. Transient Heat Conduction

    DEFF Research Database (Denmark)

    Rode, Carsten

    1998-01-01

    Analytical theory of transient heat conduction.Fourier's law. General heat conducation equation. Thermal diffusivity. Biot and Fourier numbers. Lumped analysis and time constant. Semi-infinite body: fixed surface temperature, convective heat transfer at the surface, or constant surface heat flux...

  18. EBR-II high-ramp transients under computer control

    International Nuclear Information System (INIS)

    Forrester, R.J.; Larson, H.A.; Christensen, L.J.; Booty, W.F.; Dean, E.M.

    1983-01-01

    During reactor run 122, EBR-II was subjected to 13 computer-controlled overpower transients at ramps of 4 MWt/s to qualify the facility and fuel for transient testing of LMFBR oxide fuels as part of the EBR-II operational-reliability-testing (ORT) program. A computer-controlled automatic control-rod drive system (ACRDS), designed by EBR-II personnel, permitted automatic control on demand power during the transients

  19. Development of the containment transient analysis code for the passive reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Young Dong; Kim, Young In; Bae, Yoon Young; Chang, Moon Hi [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-05-01

    This study was performed to develop the analysis tools for the passively cooled steel containment and to construct the integrated code system which can analyze a thermal hydraulic behavior of the containment and reactor system during a loss of coolant accident. The computer code CONTEMPT4/MOD5/PCCS was developed by incorporating the passive containment cooling models to the containment pressure and temperature transient analysis computer code CONTEMPT4/MOD5. The integrated reactor thermal hydraulic analysis code system for passive reactor was constructed by coupling the best estimate thermal hydraulic system analysis code RELAP5/MOD3 and CONTEMPT4/MOD5/PCCS through the process control method. In addition, to evaluate the applicability of the code the CONTEMPT4/MOD5/PCCS was applied to the SMART(System-Integrated Modular Advanced Reactor). The pressure and temperature transient following the small break LOCA of SMART was analysed by modeling the safeguard vessel using both the newly added passive containment cooling model and existing pool model. (author). 16 refs., 22 figs., 7 tabs.

  20. Abnormal autonomic cardiac response to transient hypoxia in sickle cell anemia

    International Nuclear Information System (INIS)

    Sangkatumvong, S; Khoo, M C K; Coates, T D

    2008-01-01

    The objective of this study was to non-invasively assess cardiac autonomic control in subjects with sickle cell anemia (SCA) by tracking the changes in heart rate variability (HRV) that occur following brief exposure to a hypoxic stimulus. Five African–American SCA patients and seven healthy control subjects were recruited to participate in this study. Each subject was exposed to a controlled hypoxic stimulus consisting of five breaths of nitrogen. Time-varying spectral analysis of HRV was applied to estimate the cardiac autonomic response to the transient episode of hypoxia. The confounding effects of changes in respiration on the HRV spectral indices were reduced by using a computational model. A significant decrease in the parameters related to parasympathetic control was detected in the post-hypoxic responses of the SCA subjects relative to normal controls. The spectral index related to sympathetic activity, on the other hand, showed a tendency to increase the following hypoxic stimulation, but the change was not significant. This study suggests that there is some degree of cardiovascular autonomic dysfunction in SCA that is revealed by the response to transient hypoxia