WorldWideScience

Sample records for rapid test evaluating

  1. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  2. Evaluation of a rapid immunodiagnostic test kit for rabies virus.

    Science.gov (United States)

    Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub

    2007-10-01

    A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).

  3. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  4. Modification of the Rappaport rapid test in large-scale testing for syphilis. Evaluation of the rapid plate and rapid card tests.

    Science.gov (United States)

    Ghinsberg, R; Meir, E; Blumstein, G; Kafeman, R

    1975-11-01

    The Rappaport rapid (RR) plate and card tests were developed as modifications of the RR tube test to permit rapid and inexpensive screening of large numbers of subjects for the diagnosis of syphilis. More than 2,000 sera were examined in parallel by the Venereal Disease Research Laboratory (VDRL) slide test, the rapid plasma reagin (RPR) card test and the RR plate and card tests. There was complete agreement between the RR plate and card tests and the VDRL slide and RPR card tests in 96.6% of sera. In a selected group of 1,530 sera examined, in addition, by the fluorescent treponemal antibody absorption (FTA-ABS) test, there was agreement between the RR plate and card tests and the FTA-ABS test in 74.3% of sera and between the VDRL and RPR tests and the FTA-ABS test in 73.7% of sera. The RR plate test was found to be sufficiently sensitive and specific for the diagnosis of syphilis, although the VDRL slide test is perhaps more sensitive in primary and late latent syphilis. Since the antigen used in the RR tests is colored and stable and the sera do not require inactivation before the test, the tests are easier to perform than the VDRL slide test: the RR plate and card tests could therefore replace the VDRL test as a screening test, with hardly any loss of accuracy.

  5. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  6. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  7. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease.

    Science.gov (United States)

    Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang

    2016-06-01

    Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.

  8. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  9. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  10. Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.

    Science.gov (United States)

    Shivalli, Siddharudha

    2016-05-12

    Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.

  11. Evaluation of a rapid immunodiagnostic test kit for detection of African lyssaviruses from brain material

    Directory of Open Access Journals (Sweden)

    W. Markotter

    2009-09-01

    Full Text Available Rapid immunodiagnostic test kit was evaluated against a selection of isolates of lyssavirus genotypes occurring in Africa. The test was carried out in parallel comparison with the fluorescent antibody test (FAT and isolates representing previously established phylogenetic groups from each genotype were included. The specificity of the rapid immunodiagnostic test compared favourably with the FAT and was found to detect all representatives of genotypes 1, 2, 3 and 4 in brain samples of either field cases or suckling mouse brain inoculates.

  12. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania.

    Science.gov (United States)

    Lyamuya, Eligius F; Aboud, Said; Urassa, Willy K; Sufi, Jaffer; Mbwana, Judica; Ndugulile, Faustin; Massambu, Charles

    2009-02-18

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. An

  13. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test.

    Science.gov (United States)

    Nkrumah, Bernard; Acquah, Samuel Ek; Ibrahim, Lukeman; May, Juergen; Brattig, Norbert; Tannich, Egbert; Nguah, Samuel Blay; Adu-Sarkodie, Yaw; Huenger, Frank

    2011-05-23

    About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and

  14. Evaluation of seven rapid tests for syphilis available in Brazil using defibrinated plasma panels.

    Science.gov (United States)

    Bazzo, Maria Luiza; da Motta, Leonardo Rapone; Rudolf-Oliveira, Renata Cristina Messores; Bigolin, Alisson; Golfetto, Lisléia; Mesquita, Fábio; Benzaken, Adele Schwartz; Gaspar, Pamela Cristina; Pires, Ana Flavia Nacif P Coelho; Ferreira Júnior, Orlando da Costa; Franchini, Miriam

    2017-12-01

    In 2012, the WHO estimated that 6 million new cases of syphilis per year would occur worldwide, including 937 000 in Brazil. Early diagnosis and treatment of syphilis are essential to reduce morbidity and prevent transmission. The availability of rapid tests (RTs) for this diagnosis means that testing can be performed more quickly, as a point-of-care test, even in non-laboratory environments and requires only simple technical training to antibodies detection. The objective of this study was to evaluate the performance and operational aspects of seven commercially available RTs for syphilis in Brazil. Seven rapid treponemal tests were evaluated for sensitivity, specificity, accuracy and Kappa value, according to a panel composed of 493 members. The operational performance of the assay was also determined for these tests. The seven RTs showed sensitivity ranging from 94.5% to 100% when compared with the reference tests and specificity of between 91.5% and 100%. All the RTs evaluated presented good operational performance, and only one failed to present the minimum specificity as defined by Brazil's Ministry of Health. All the tests presented good operational performance, and the professionals who performed them considered them to be easy to use and interpret. This evaluation is important for making informed choices of tests to be used in the Brazilian Unified Health System. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Comparative evaluation of two rapid Salmonella-IgM tests and blood culture in the diagnosis of enteric fever.

    Science.gov (United States)

    Prasad, K J; Oberoi, J K; Goel, N; Wattal, C

    2015-01-01

    Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.

  16. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Mbwana Judica

    2009-02-01

    Full Text Available Abstract Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical, SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc., First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd, HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc and Uni-Gold™ HIV-1/2 (Trinity Biotech were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics. Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100 while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9 and 97.7% (95% CI; 95.7–98.9, respectively, which increased to 100% (95% CI; 99.1–100 on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100 while specificities were 99.6% (95% CI; 99–99.9, 99.4% (95% CI; 98.8–99.7, 99.6% (95% CI; 99–99.9 and 99.8% (95% CI; 99.3–99.9 for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was

  17. [Evaluation of a rapid trehalase test for the identification of Candida glabrata].

    Science.gov (United States)

    Kirdar, Sevin; Gültekin, Berna; Evcil, Gonca; Ozkütük, Aydan; Sener, Asli Gamze; Aydin, Neriman

    2009-04-01

    Candida species which cause local infections, may also lead to fatal systemic infections. The increasing incidence of non-albicans Candida, especially fluconazole susceptible or resistant dose-dependent C. glabrata, increased the importance of rapid and accurate species level identification for Candida. Rapid and correct identification of C. glabrata is essential for the initiation of the appropriate antifungal therapy. This study was conducted to evaluate the performance of the rapid trehalase test in the diagnosis of C. glabrata isolates. A total of 173 Candida strains isolated from various clinical specimens and identified according to germ tube test, growth on cornmeal Tween 80 agar and the colony morphologies on Mast-CHROMagar Candida medium (Mast Diagnostics, UK), were included to the study. The identification of non-albicans Candida species were also confirmed by API 20CAUX (BioMerieux, France) system. Accordingly 86 (50%) of the isolates were identified as C. glabrata, 48 (28%) C. albicans, 17 (10%) C. krusei, 13 (8%) C. tropicalis, 5 (3%) C. parapsilosis, 3 (2%) C. kefyr and 1 (1%) Cutilis. In order to detect the presence of trehalase enzyme in Condida strains, all isolates were grown on Sabouraud dextrose agar containing 4% glucose and then one yeast colony was emulsified in 50 microl of citrate buffer containing 4% (wt/vol) trehalose for 3 h at 37 degrees C. Presence of glucose which emerged after the action of trehalase on trehalose, was detected by a commercial "urinary glucose detection dipstick" (Spinreacta, Spain). All C. glabrata strains yielded positive result by trehalase test. None C. glabrata isolates were found negative by trehalase test except for one strain of C. tropicalis. In this study, the trehalase test allowed identification of C. globrata with 100% sensitivity and 98.9% specificity. It was concluded that trehalase test is a rapid, cost-effective and simple test that can be used for the accurate identification of C. glabrata.

  18. Effect of sweet yeast bread formula on evaluating rapid mix test

    Directory of Open Access Journals (Sweden)

    Petra Dvořáková

    2011-01-01

    Full Text Available The aim of this work was to detect how different sweet yeast bread formulas influence results of rapid mix test and by the help of sensory analysis to discover consumer preferences and possible benefit and use in bakery industry. Applied raw materials (ground wheat flour T 530, yeast, sugar, salt, oil, egg, improver Hit along with basic formula were taken from the Varmužova bakery in Boršice by Buchlovice. The basic formula served as a standard (I, other six formulas were then determined (II–VII. In each formula, the rate of yeast, sugar or oil was altered in the range of ± 10% compared with the standard. Flour bread-making quality – Hagberg Falling number [s], Sedimentation index [ml], wet gluten [%], ash [%], moisture [%], binding capacity [%], granulation [%], alveographic energy [10−4J] and alveographic rate P/L – was measured. Rapid mix test and parameters like pastry weight, volume, shape, dough yield, pastry yield, baking loss, penetration and sensory analysis were determined. To establish yeast fermentation activity, Engelke fermentation test was applied. The most evident differences among the samples appeared in the volume and shape. The results of sensory analysis showed that the samples with higher rate of altered raw materials were evaluated as the best.

  19. Evaluation of Blood-Based Antibody Rapid Testing for HIV Early Therapy: A Meta-Analysis of the Evidence

    Directory of Open Access Journals (Sweden)

    Xiaojie Huang

    2018-06-01

    Full Text Available BackgroundWestern blot (WB assay is considered the gold standard test for HIV infection confirmation. However, it requires technical expertise and is quite time-consuming. WHO recommends blood-based rapid diagnosis to achieve same-day test and treatment. However, this rapid testing strategy has not been promoted worldwide due to inadequate research evaluating the effectiveness of rapid tests (RTs as an alternative confirmatory HIV test for WB. This study aims to compare the diagnostic performance of rapid HIV tests compared with WB.MethodsPubMed and Web of Science were searched for publications on rapid HIV tests using blood specimen. A meta-analysis was performed to quantitatively evaluate the diagnostic performance of rapid HIV tests compared with the WB assay in terms of pooled sensitivity, specificity, area under summary receiver operating characteristic (SROC curve, and diagnostic odds ratio (DOR.ResultsTwenty articles involving 27,343 fresh specimens for rapid HIV tests were included in the meta-analysis. Regarding Capillus HIV-1/HIV-2, the pooled sensitivity, specificity, area under SROC curve, and DOR derived from six studies were 0.999 (95% CI, 0.956–1.000, 0.999 (95% CI, 0.991–1.00, 1.00 (95% CI, 0.99–1.00, and 1.0 × 106 (95% CI, 2.6 × 104–3.9 × 107 compared with the WB assay, respectively. With respect to Determine HIV-1/2, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 1.00 (95% CI, 0.789–1.000, 0.992 (95% CI, 0.985–0.996, 1.00 (95% CI, 0.99–1.00, and 1.8 × 106 (95% CI 406.049–7.8 × 109 compared with the WB assay, respectively. Regarding two-step serial RTs, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 0.998 (95% CI, 0.991–1.000, 0.998 (95% CI, 0.994–0.999, and 1.00 (95% CI 0.99–1.00 compared with the WB assay, respectively.ConclusionOur meta-analysis results may provide evidenced-based support

  20. Evaluation of rapid radiometric method for drug susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Libonati, J.P.; Middlebrook, G.

    1981-01-01

    A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with 14 C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests results reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations

  1. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    Science.gov (United States)

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  2. Rapid Aminoglycoside NP Test for Rapid Detection of Multiple Aminoglycoside Resistance in Enterobacteriaceae.

    Science.gov (United States)

    Nordmann, Patrice; Jayol, Aurélie; Dobias, Jan; Poirel, Laurent

    2017-04-01

    The rapid aminoglycoside NP (Nordmann/Poirel) test was developed to rapidly identify multiple aminoglycoside (AG) resistance in Enterobacteriaceae It is based on the detection of the glucose metabolism related to enterobacterial growth in the presence of a defined concentration of amikacin plus gentamicin. Formation of acid metabolites was evidenced by a color change (orange to yellow) of the red phenol pH indicator. The rapid aminoglycoside NP test was evaluated by using bacterial colonies of 18 AG-resistant isolates producing 16S rRNA methylases, 20 AG-resistant isolates expressing AG-modifying enzymes (acetyl-, adenyl-, and phosphotransferases), and 10 isolates susceptible to AG. Its sensitivity and specificity were 100% and 97%, respectively, compared to the broth dilution method, which was taken as the gold standard for determining aminoglycoside resistance. The test is inexpensive, rapid (<2 h), and implementable worldwide. Copyright © 2017 American Society for Microbiology.

  3. Kato-Katz and Lumbreras rapid sedimentation test to evaluate helminth prevalence in the setting of a school-based deworming program

    OpenAIRE

    Lopez, Martha; Morales, Maria Luisa; Konana, Monisha; Hoyer, Paige; Pineda-Reyes, Roberto; White, Arthur Clinton; Garcia, Hector Hugo; Lescano, Andres Guillermo; Gotuzzo, Eduardo; Cabada, Miguel Mauricio

    2016-01-01

    The sensitivity of the Kato-Katz test is suboptimal for the evaluation of intestinal helminth prevalence. Moreover, during mass deworming, as helminth egg burden decreases, the sensitivity is likely to decrease. The Lumbreras rapid sedimentation (Lumbreras) is a low-cost non-quantitative test, but may provide useful information in low burden areas. We compared the prevalence of intestinal helminth infections assessed by the Kato-Katz and the Lumbreras rapid sedimentation test on 3 stool speci...

  4. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured by the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.

  5. Evaluation of the OnSite malaria rapid test performance in Miandrivazo, Madagascar.

    Science.gov (United States)

    Ravaoarisoa, E; Andriamiandranoro, T; Raherinjafy, R; Jahevitra, M; Razanatsiorimalala, S; Andrianaranjaka, V; Randrianarivelojosia, M

    2017-10-01

    The performance of the malaria rapid diagnostic test OnSite-for detecting pan specific pLDH and Plasmodium falciparum specific HRP2 - was assessed during the malaria transmission peak period in Miandrivazo, in the southwestern part of Madagascar from April 20 to May 6, 2010. At the laboratory, the quality control OnSite Malaria Rapid Test according to the WHO/TDR/FIND method demonstrated that the test had good sensitivity. Of the 218 OnSite tests performed at the Miandrivazo Primary Health Center on patients with fever or a recent history of fever, four (1.8%, 95% CI: 0.6-4.9%) were invalid. Ninety four (43,1%) cases of malaria were confirmed by microscopy, of which 90 were P. falciparum malaria and 4 Plasmodium vivax malaria. With a Cohen's kappa coefficient of 0.94, the agreement between microscopy and OnSite is excellent. Compared with the rapid test CareStart™ commonly used within the public health structures in Madagascar, the sensitivity and specificity of the OnSite test were 97.9% and 96.8%.

  6. Kato-Katz and Lumbreras rapid sedimentation test to evaluate helminth prevalence in the setting of a school-based deworming program

    Science.gov (United States)

    Lopez, Martha; Morales, Maria Luisa; Konana, Monisha; Hoyer, Paige; Pineda-Reyes, Roberto; White, Arthur Clinton; Garcia, Hector Hugo; Lescano, Andres Guillermo; Gotuzzo, Eduardo; Cabada, Miguel Mauricio

    2016-01-01

    The sensitivity of the Kato-Katz test is suboptimal for the evaluation of intestinal helminth prevalence. Moreover, during mass deworming, as helminth egg burden decreases, the sensitivity is likely to decrease. The Lumbreras rapid sedimentation (Lumbreras) is a low-cost non-quantitative test, but may provide useful information in low burden areas. We compared the prevalence of intestinal helminth infections assessed by the Kato-Katz and the Lumbreras rapid sedimentation test on 3 stool specimens from each of 1083 children. The sensitivities were compared using the McNemar paired test. Using the combined outcome of the 3 different stool tests as the standard, Kato-Katz had lower sensitivity than Lumbreras rapid sedimentation tests for Ascaris lumbricoides (85.1% vs. 95.1%, p = 0.03), Hymenolepis nana (77.7% vs. 97.9%, p Lumbreras rapid sedimentation tests enables the detection of more intestinal helminths infections in post-deworming low prevalence areas. PMID:27376503

  7. Evaluating the use of dedicated swab for rapid antigen detection ...

    African Journals Online (AJOL)

    Evaluating the use of dedicated swab for rapid antigen detection testing in group a ... African Journal of Clinical and Experimental Microbiology ... Several generations of rapid antigen detection tests (RADTs) have been developed to facilitate ...

  8. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  9. Field evaluation of a dual rapid diagnostic test for HIV infection and syphilis in Lima, Peru.

    Science.gov (United States)

    Bristow, Claire C; Leon, Segundo R; Huang, Emily; Brown, Brandon J; Ramos, Lourdes B; Vargas, Silver K; Flores, Juan A; Caceres, Carlos F; Klausner, Jeffrey D

    2016-05-01

    Screening for HIV and syphilis in key populations is recommended by the WHO to reduce the morbidity, mortality and transmission associated with undiagnosed and untreated infections. Rapid point-of-care tests that can detect multiple infections with a single fingerprick whole blood specimen using a single device are gaining popularity. We evaluated the field performance of a rapid dual HIV and syphilis test in people at high risk of HIV and syphilis infections. Participants included men who have sex with men and transgender women recruited in Lima, Peru. Reference standard testing for detection of HIV and syphilis infections, conducted using blood samples from venipuncture, included Treponema pallidum particle agglutination and fourth-generation HIV enzyme immunoassay for which positive results had a confirmation HIV Western blot test. For the evaluation test, SD BIOLINE HIV/Syphilis Duo test (Standard Diagnostics, Korea), a fingerprick blood specimen was used. Sensitivity and specificity were calculated and the exact binomial method was used to determine 95% CIs. A total of 415 participants were recruited for the study. The dual test sensitivity for detection of T. pallidum infection was 89.2% (95% CI 83.5% to 93.5%) and specificity 98.8% (95% CI 96.5% to 99.8%). For detection of HIV infection, the sensitivity of the dual test was 99.1% (95% CI 94.8% to 100%) and specificity 99.4% (95% CI 97.7% to 99.9%). This high performing dual test should be considered for the use in clinical settings to increase uptake of simultaneous testing of HIV and syphilis and accelerate time to treatment for those who need it. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests.

    Science.gov (United States)

    Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene

    2018-01-01

    Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.

  11. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    To test whole blood and saliva for HIV antibodies. (anti-HIV) using a rapid test strip capillary flow . immunoassay ... Design. A prospective pilot study of selected HIV-positive and ... defined by the underlying illness or condition is illustrated in.

  12. Evaluation of a rapid test for HIV antibodies in saliva and blood ...

    African Journals Online (AJOL)

    Objective. To test whole blood and saliva for HIV antibodies (anti-HIV) using a rapid test strip capillary flow . immunoassay, and to correlate the test strip results with blood specimen results obtained from routine diagnostic antiHIV assays. Design. A prospective pilot study of selected HIV-positive and HIV-negative individuals ...

  13. Laboratory evaluation of three dual rapid diagnostic tests for HIV and syphilis in China and Nigeria.

    Science.gov (United States)

    Yin, Yue-Ping; Ngige, Evelyn; Anyaike, Chukwuma; Ijaodola, Gbenga; Oyelade, Taiwo A; Vaz, Rui Gama; Newman, Lori M; Chen, Xiang-Sheng

    2015-06-01

    To determine the laboratory-based performance and operational characteristics of three dual rapid diagnostic tests (RDTs) for testing HIV and syphilis. Three dual RDTs (SD Bioline, Chembio, and MedMira) were evaluated using 1514 serum specimens archived at laboratories or collected from clinics in China and Nigeria to determine sensitivity and specificity, with 95% confidence intervals. Concordance of testing results read by two technicians, stability of testing results read at two time points, and test operation characteristics were also assessed. All three of the evaluated RDTs gave excellent performance with a combined sensitivity ranging from 99.0%-99.6% for HIV and 98.3%-99.0% for syphilis, and a combined specificity ranging from 97.9%-99.0% for HIV and 97.2%-99.6% for syphilis. Concordance of testing results between two technicians and stability of testing results read within and one hour past the recommended reading period showed excellent agreement, with Kappa greater than or equal to 0.98. All the tests were found to be very or fairly easy to use and easy to interpret the results. Further evaluations of these dual RDTs with whole blood in field settings, and more studies on the implication of introduction of these tests in HIV and syphilis control programs are needed. Copyright © 2015. Published by Elsevier Ireland Ltd.

  14. Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity

    Science.gov (United States)

    2016-03-07

    109 | e53555 | Page 1 of 8 Video Article Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of...www.jove.com/ video /53555 DOI: doi:10.3791/53555 Keywords: Environmental Sciences, Issue 109, Fish cells, impedance, sensors, biochip, water toxicity...sensitivity to cholinesterase-inhibiting pesticides . Applications for this toxicity detector are for rapid field-portable testing of drinking water

  15. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  16. Low specificity of 2 tetanus rapid tests in Cambodia.

    Science.gov (United States)

    Schlumberger, M; Yvonnet, B; Lesage, G; Tep, B

    2015-01-01

    Rapid testing for tetanus on serum or blood allows for an immediate evaluation of individual protection against tetanus in developed countries, using a "single step" immunochromatographic technique using tetanus toxoid. The specificity of these tests, compared to the reference method for tetanus, mouse serum neutralization testing, has however never been assessed in these countries, due to the difficulty to perform serum neutralization titration in mice, because of animal testing bioethical regulations. A collection of sera from adult volunteers in Cambodia, living in rural environment, was tested for tetanus antibodies by ELISA in France, and by mouse serum neutralization in Vietnam. This allowed estimating the sensitivity and specificity of 2 rapid tetanus tests, available on the market: TQS™ and Tetanotop™. The sensitivity of these tests was adequate, compared to mice serum neutralization test, for a test threshold of 0.01 IU/mL, (100% for TQS™, 91% for Tetanotop™), but their specificity was very low (1% for TQS™ and 13% for Tetanotop™). The results prove that these rapid tests for the assessment of individual protection against tetanus should not be used in the adult rural Cambodian population. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Evaluation of a rapid immunochromatographic ODK-0901 test for detection of pneumococcal antigen in middle ear fluids and nasopharyngeal secretions.

    Directory of Open Access Journals (Sweden)

    Muneki Hotomi

    Full Text Available Since the incidence of penicillin-resistant Streptococcus pneumoniae has been increasing at an astonishing rate throughout the world, the need for accurate and rapid identification of pneumococci has become increasingly important to determine the appropriate antimicrobial treatment. We have evaluated an immunochromatographic test (ODK-0901 that detects pneumococcal antigens using 264 middle ear fluids (MEFs and 268 nasopharyngeal secretions (NPSs. A sample was defined to contain S. pneumoniae when optochin and bile sensitive alpha hemolytic streptococcal colonies were isolated by culture. The sensitivity and specificity of the ODK-0901 test were 81.4% and 80.5%, respectively, for MEFs from patients with acute otitis media (AOM. In addition, the sensitivity and specificity were 75.2% and 88.8%, respectively, for NPSs from patients with acute rhinosinusitis. The ODK-0901 test may provide a rapid and highly sensitive evaluation of the presence of S. pneumoniae and thus may be a promising method of identifying pneumococci in MEFs and NPSs.

  18. [Rapid test for detection of susceptibility to cefotaxime in Enterobacteriaceae].

    Science.gov (United States)

    Jiménez-Guerra, Gemma; Hoyos-Mallecot, Yannik; Rodríguez-Granger, Javier; Navarro-Marí, José María; Gutiérrez-Fernández, José

    In this work an "in house" rapid test based on the change in pH that is due to hydrolysis for detecting Enterobacteriaceae susceptible to cefotaxime is evaluated. The strains of Enterobacteriaceae from 1947 urine cultures were assessed using MicroScan panels and the "in house" test. This rapid test includes red phenol solution and cefotaxime. Using MicroScan panels, 499 Enterobacteriaceae isolates were evaluated, which included 27 isolates of Escherichia coli producing extended-spectrum beta-lactamases (ESBL), 16 isolates of Klebsiella pneumoniae ESBL and 1 isolate of Klebsiella oxytoca ESBL. The "in house" test offers the following values: sensitivity 98% and specificity 97%, with negative predictive value 100% and positive predictive value 78%. The "in house" test based on the change of pH is useful in our area for detecting presumptively cefotaxime-resistant Enterobacteriaceae strains. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    Science.gov (United States)

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  20. Evaluation of PDA Technical Report No 33. Statistical Testing Recommendations for a Rapid Microbiological Method Case Study.

    Science.gov (United States)

    Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David

    2015-01-01

    New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc

  1. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa

    OpenAIRE

    Jaya, Ziningi; Drain, Paul K.; Mashamba-Thompson, Tivani P.

    2017-01-01

    Introduction Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. Material and methods We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and couns...

  2. [Evaluation of a rapid diagnostic test in the diagnosis of toxoplasmosis in pregnant women in Cotonou (Bénin)].

    Science.gov (United States)

    Ogouyèmi-Hounto, A; Agbayahoun-Chokki, F; Sissinto Savi de Tove, Y; Biokou Bankole, B; Adinsi de Souza, V; Assogba, M; Kinde-Gazard, D; Massougbodji, A

    2014-05-01

    The aim of the study was to evaluate the performance of the ImmunoComb® Toxo IgG and ImmunoComb® Toxo IgMassays (rapid diagnostic test) in the laboratory diagnosis of toxoplasmosis in pregnant women in Cotonou. We interviewed 266 pregnant women, who first answered an epidemiological questionnaire, and collected blood samples for measurement of IgG and IgM anti T. gondii antibodies with the ImmunoComb toxo assays and with the ARCHITECT CIMA method. The sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) were calculated to determine the performance of the rapid test. The seroprevalences of IgG against T. gondii by CIMA technique and rapid test were respectively 48.9% and 48.5%. The prevalence increased with age. Performances for IgG were: sensitivity 97%, specificity 100%, PPV 100%, NPV = 97.10%. For IgM, Sensitivity: 33.3% Specificity: 100%, PPV 100%, NPV = 99.2%. Seroprevalence obtained shows that about half of the study population is not immune against T. gondii and requires regular serological monitoring until delivery. According to these results, and given the needs of toxoplasmosis diagnosis on the field characterized by an important decrease of immunized women, this test may be recommended in the laboratory diagnosis of toxoplasmosis in peripheral levels of the health pyramid.

  3. The diagnostic sensitivity of dengue rapid test assays is significantly enhanced by using a combined antigen and antibody testing approach.

    Directory of Open Access Journals (Sweden)

    Scott R Fry

    2011-06-01

    Full Text Available BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1 has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum. AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test. METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples. KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6% and 96% (95% CI: 92.2% to 99.8 respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1% and 96.7% specificity (95% CI: 82.8% to 99.9% compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers. CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.

  4. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    Science.gov (United States)

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  5. HIV rapid testing in a Veterans Affairs hospital ED setting: a 5-year sustainability evaluation.

    Science.gov (United States)

    Knapp, Herschel; Hagedorn, Hildi; Anaya, Henry D

    2014-08-01

    Routine HIV testing in primary care settings is now recommended in the United States. The US Department of Veterans Affairs (VA) has increased the number of patients tested for HIV, but overall HIV testing rates in VA remain low. A proven strategy for increasing such testing involves nurse-initiated HIV rapid testing (HIV RT). The purpose of this work was to use a mixed methodology approach to evaluate the 5-year sustainability of an intervention that implemented HIV RT in a VA emergency department setting in a large, urban VA medical center to reduce missed diagnostic and treatment opportunities in this vulnerable patient population. In-person semistructured interviews were conducted with providers and stakeholders. Interview notes were qualitatively coded for emerging themes. Quarterly testing rates were evaluated for a 5-year time span starting from the launch in July 2008. Findings indicate that HIV RT was sustained by the enthusiasm of 2 clinical champions who oversaw the registered nurses responsible for conducting the testing. The departure of the clinical champions was correlated with a substantial drop-off in testing. Findings also indicate potential strategies for improving sustainability including engaging senior leadership in the project, engaging line staff in the implementation planning from the start to increase ownership over the innovation, incorporating information into initial training explaining the importance of the innovation to quality patient care, providing ongoing training to maintain skills, and providing routine progress reports to staff to demonstrate the ongoing impact of their efforts. Published by Elsevier Inc.

  6. Screening test for rapid food safety evaluation by menadione-catalysed chemiluminescent assay.

    Science.gov (United States)

    Yamashoji, Shiro; Yoshikawa, Naoko; Kirihara, Masayuki; Tsuneyoshi, Toshihiro

    2013-06-15

    The chemiluminescent assay of menadione-catalysed H2O2 production by living mammalian cells was proposed to be useful for rapid food safety evaluation. The tested foods were extracted with water, ethanol and dimethylsulfoxide, and each extract was incubated with NIH3T3, Neuro-2a and HepG2 cells for 4h. Menadione-catalysed H2O2 production by living mammalian cells exposed to each extract was determined by the chemiluminescent assay requiring only 10 min, and the viability of the cells was estimated as percentage based on H2O2 production by intact cells. In this study the cytotoxicity of food was rated in order of inhibitory effect on H2O2 production by intact cells. The well known natural toxins such as Fusarium mycotoxin, tomato toxin tomatine, potato toxin solanine and marine toxins terodotoxin and brevetoxin could be detected by the above chemiluminescent assay. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Rapid lysostaphin test to differentiate Staphylococcus and Micrococcus species.

    Science.gov (United States)

    Geary, C; Stevens, M

    1986-01-01

    A rapid, simple lysostaphin lysis susceptibility test to differentiate the genera Staphylococcus and Micrococcus was evaluated. Of 181 strains from culture collections, 95 of 95 Staphylococcus strains were lysed, and 79 of 79 Micrococcus strains were not lysed. The seven Planococcus strains were resistant. Clinical isolates (890) were tested with lysostaphin and for the ability to produce acid from glycerol in the presence of erythromycin. Overall agreement between the methods was 99.2%. All clinical Micrococcus strains (43) were resistant to lysostaphin, and all clinical Staphylococcus strains (847) were susceptible. Seven of the Staphylococcus strains did not produce acid from glycerol in the presence of erythromycin. This lysostaphin test provides results in 2 h. It is easier to perform than previously described lysostaphin lysis methods. It is also more rapid and accurate than the glycerol-erythromycin test. PMID:3519667

  8. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Marga G A Goris

    Full Text Available BACKGROUND: Diagnosis of leptospirosis by the microscopic agglutination test (MAT or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. METHODOLOGY: During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. RESULTS: The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB, but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB. CONCLUSIONS: All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.

  9. [Attempt for development of rapid word reading test for children--evaluation of reliability and validity].

    Science.gov (United States)

    Hashimoto, Ryusaku; Kashiwagi, Mitsuru; Suzuki, Shuhei

    2008-09-01

    We developed a rapid word reading test for examining the phonological processing ability of Japanese children. We prepared two versions of the test, version A and B. Each test has word and non-word tasks. Twenty-two healthy boys of third grade in primary schools participated in this validation study. For criterion related validity, we performed the serial Hiragana reading test, the sentence reading test, Raven's coloured progressive matrices (RCPM), the Token test for children, the Kana word dictation test, the standardized comprehension test of abstract words (SCTAW), and Trail Circle test. The reading times of the newly developed test correlated moderately or highly with those of the serial Hiragana reading test and the sentence reading test. However, the scores of the other tests (RCPM, Token test for children, Kana word dictation test, SCTAW, Trail Circle test) did not correlated with the reading time of the rapid word reading test. Test-retest reliabilities in the word tasks were more than moderate: 0.52 and 0.76 in versions A and B, while those in the non-word tasks were high: 0.91 and 0.88 in versions A and B. The correlation coefficient between versions A and B was 0.7 for the word tasks and 0.92 for the non-word tasks. This study showed that the rapid word reading test has substantial validity and reliability for testing the phonological processing ability of Japanese children. In addition, the non-word tasks were more suitable for selectively examining the speed of the grapheme to phoneme conversion process.

  10. The evaluation of a rapid in situ HIV confirmation test in a programme with a high failure rate of the WHO HIV two-test diagnostic algorithm.

    Directory of Open Access Journals (Sweden)

    Derryck B Klarkowski

    Full Text Available BACKGROUND: Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT (two positive RDTs alone for HIV diagnosis used in voluntary counselling and testing (VCT sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives. METHODOLOGY/PRINCIPAL FINDINGS: 2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV. Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2. 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7 when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9% with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used. CONCLUSIONS: The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC

  11. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  12. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  13. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    2014-09-01

    Full Text Available Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA setting.

  14. A Global Comparative Evaluation of Commercial Immunochromatographic Rapid Diagnostic Tests for Visceral Leishmaniasis

    NARCIS (Netherlands)

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen; Khanal, Basudha; Das, Murari; Oliveira, Edward; de Assis, Tália Machado; Costa, Dorcas Lamounier; Bhaskar, Khondaker Rifathassan; Huda, M. Mamun; Hassan, Mukidul; Abdoun, Asim Osman; Awad, Aymen; Osman, Mohamed; Prajapati, Dinesh Kumar; Gidwani, Kamlesh; Tiwary, Puja; Paniago, Anamaria Mello Miranda; Sanchez, Maria Carmen Arroyo; Celeste, Beatriz Julieta; Jacquet, Diane; Magiri, Charles; Muia, A.; Kesusu, J.; Ageed, Al Farazdag; Galal, Nuha; Osman, Osman Salih; Gupta, A. K.; Bimal, Afrad S.; Das, V. N. R.

    2012-01-01

    Background. Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Methods. Commercial VL RDTs

  15. Evaluation of four colourimetric susceptibility tests for the rapid detection of multidrug-resistant Mycobacterium tuberculosisisolates

    Directory of Open Access Journals (Sweden)

    Ahmet Yilmaz Coban

    2015-08-01

    Full Text Available The purpose of this study is to evaluate four rapid colourimetric methods, including the resazurin microtitre assay (REMA, malachite green decolourisation assay (MGDA, microplate nitrate reductase assay (MNRA and crystal violet decolourisation assay (CVDA, for the rapid detection of multidrug-resistant (MDR tuberculosis. Fifty Mycobacterium tuberculosisisolates were used in this study. Eighteen isolates were MDR, two isolates were only resistant to isoniazid (INH and the remaining isolates were susceptible to both INH and rifampicin (RIF. INH and RIF were tested in 0.25 µg/mL and 0.5 µg/mL, respectively. The agar proportion method was used as a reference method. MNRA and REMA were performed with some modifications. MGDA and CVDA were performed as defined in the literature. The agreements of the MNRA for INH and RIF were 96% and 94%, respectively, while the agreement of the other assays for INH and RIF were 98%. In this study, while the specificities of the REMA, MGDA and CVDA were 100%, the specificity of the MNRA was lower than the others (93.3% for INH and 90.9% for RIF. In addition, while the sensitivity of the MNRA was 100%, the sensitivities of the others were lower than that of the MNRA (from 94.1-95%. The results were reported on the seventh-10th day of the incubation. All methods are reliable, easy to perform, inexpensive and easy to evaluate and do not require special equipment.

  16. Design, development and evaluation of rK28-based point-of-care tests for improving rapid diagnosis of visceral leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Sowmya Pattabhi

    Full Text Available BACKGROUND: Visceral leishmaniasis (VL is diagnosed by microscopic confirmation of the parasite in bone marrow, spleen or lymph node aspirates. These procedures are unsuitable for rapid diagnosis of VL in field settings. The development of rK39-based rapid diagnostic tests (RDT revolutionized diagnosis of VL by offering high sensitivity and specificity in detecting disease in the Indian subcontinent; however, these tests have been less reliable in the African subcontinent (sensitivity range of 75-85%, specificity of 70-92%. We have addressed limitations of the rK39 with a new synthetic polyprotein, rK28, followed by development and evaluation of two new rK28-based RDT prototype platforms. METHODOLOGY/PRINCIPAL FINDINGS: Evaluation of 62 VL-confirmed sera from Sudan provided sensitivities of 96.8% and 93.6% (95% CI = K28: 88.83-99.61%; K39: 84.30-98.21% and specificities of 96.2% and 92.4% (95% CI = K28: 90.53-98.95%; K39: 85.54-96.65% for rK28 and rK39, respectively. Of greater interest was the observation that individual VL sera with low rK39 reactivity often had much higher rK28 reactivity. This characteristic of the fusion protein was exploited in the development of rK28 rapid tests, which may prove to be crucial in detecting VL among patients with low rK39 antibody levels. Evaluation of two prototype lateral flow-based rK28 rapid tests on 53 VL patients in Sudan and 73 VL patients in Bangladesh provided promisingly high sensitivities (95.9% [95% CI = 88.46-99.1 in Sudan and 98.1% [95% CI = 89.93-99.95%] in Bangladesh compared to the rK39 RDT (sensitivities of 86.3% [95% CI = 76.25-93.23%] in Sudan and 88.7% [95% CI = 76.97-95.73%] in Bangladesh. CONCLUSIONS/SIGNIFICANCE: Our study compares the diagnostic accuracy of rK39 and rK28 in detecting active VL cases and our findings indicate that rK28 polyprotein has great potential as a serodiagnostic tool. A new rK28-based RDT will prove to be a valuable asset in

  17. Improving prescribing practices with rapid diagnostic tests (RDTs)

    DEFF Research Database (Denmark)

    Burchett, Helen E D; Leurent, Baptiste; Baiden, Frank

    2017-01-01

    OBJECTIVES: The overuse of antimalarial drugs is widespread. Effective methods to improve prescribing practice remain unclear. We evaluated the impact of 10 interventions that introduced rapid diagnostic tests for malaria (mRDTs) on the use of tests and adherence to results in different contexts...... packages, supervision, supplies and community sensitisation. OUTCOME MEASURES: Analysis explored variation in: (1) uptake of mRDTs (% febrile patients tested); (2) provider adherence to positive mRDTs (% Plasmodium falciparum positive prescribed/given Artemisinin Combination Treatment); (3) provider...... characteristics fitted with their own priorities. Goodness of fit of mRDTs with existing consultation and diagnostic practices appeared crucial to maximising the impact of mRDTs on care, as did prior familiarity with malaria testing; adequate human resources and supplies; possible alternative treatments for m...

  18. Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.

    OpenAIRE

    Hambie, E A; Larsen, S A; Perryman, M W; Pettit, D E; Mullally, R L; Whittington, W

    1983-01-01

    The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Beckman Instruments, Inc., for evaluation. Qualitative agreement among the three RPR card tests was 98....

  19. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-01-01

    criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence rates in the study populations ranged from 1% to 75% (median prevalence 24%, interquartile range (IQR) 11% to 46%). The included studies evaluated 16 different RDTs, and 16 studies compared two or more different RDTs. Only three studies used the Grade 1 reference standard, and only 11 studies recruited unselected febrile patients. Most included studies were from Asia, with five studies from sub-Saharan Africa. All of the RDTs were designed to detect S.Typhi infection only. Most studies evaluated three RDTs and their variants: TUBEX in 14 studies; Typhidot (Typhidot, Typhidot-M, and TyphiRapid-Tr02) in 22 studies; and the Test-It Typhoid immunochromatographic lateral flow assay, and its earlier prototypes (dipstick, latex agglutination) developed by the Royal Tropical Institute, Amsterdam (KIT) in nine studies. Meta-analyses showed an average sensitivity of 78% (95% confidence interval (CI) 71% to 85%) and specificity of 87% (95% CI 82% to 91%) for TUBEX; and an average sensitivity of 69% (95% CI 59% to 78%) and specificity of 90% (95% CI 78% to 93%) for all Test-It Typhoid and prototype tests (KIT). Across all forms of the Typhidot test, the average sensitivity was 84% (95% CI 73% to 91%) and specificity was 79% (95% CI 70% to 87%). When we based the analysis on the 13 studies of the Typhidot test that either reported indeterminate test results or where the test format means there are no indeterminate results, the average sensitivity was 78% (95% CI 65% to 87%) and specificity was 77% (95% CI 66% to 86%). We did not identify any difference in either sensitivity or specificity between TUBEX, Typhidot, and Test-it Typhoid tests when based on comparison to the 13 Typhidot studies where indeterminate results are either reported or not applicable. If TUBEX and Test-it Typhoid are compared to all Typhidot studies, the sensitivity of Typhidot was higher than Test-it Typhoid (15% (95

  20. Evaluation of a new rapid lateral flow chromatography test for the diagnosis of Helicobacter Pylori

    International Nuclear Information System (INIS)

    Kaklikkaya, N.; Dinc, U.; Dabanca, Pinar A.; Aydin, F.; Erturk, M.; Akdogan, Remzi A.; Ozgur, O.; Uzun, Dogan Y.; Gungor, E.; Arslan, M.; Cobanoglu, U.

    2006-01-01

    The rapid, simple and non-invasive diagnosis of Helicobacter pylori (H. pylori) infection is important in implementing chemotherapy in appropriate manner, and in assessing persistent H. pylori infection after eradication therapy. The Immuno Card STAT HpSA kit (Meridian Bioscience, Europe) is a lateral flow chromatography test which utilizes a monoclonal anti-H. pylori antibody. In this study, we investigated the usefulness of the ImmunoCard STAT HpSA test before and after eradication therapy on patients referred to undergo upper gastrointestinal endoscopy. Sixty-five consecutive patients who were referred to undergo upper gastrointestinal endoscopy at the Department of Gastroenterology, Karadeniz Technical University Medical School, Turkey between February and August 2005 were included in this study. The ImmunoCard STAT HpSA was compared with 4 invasive tests (histology, gram staining, rapid urease test, and culture). The reference method was defined as positive when 2 of the 4 invasive tests were positive. A negative H. pylori status was considered when all 4 tests present concordant negative results. Overall, the ImmunoCard STAT HpSA test had 77.8% sensitivity, 79.3% specificity, 82.4% positive predictive value (PPV) and 74.2% negative predictive value (NPV) in all patients. With regard to pre-treatment values, the sensitivity was 70.6%, specificity 70.6%, PPV 100% and NPV 100% while on post-treatment group the sensitivity was 84.2%, specificity 64.7%, PPV 72.7% and NPV 78.6%. Our results indicate that the ImmunoCard STAT HpSA test is a rapid, simple, and helpful procedure not only to determine H. pylori infection but also to assess the success of eradication therapy. (author)

  1. A Highly Sensitive Rapid Diagnostic Test for Chagas Disease That Utilizes a Recombinant Trypanosoma cruzi Antigen

    Science.gov (United States)

    Barfield, C. A.; Barney, R. S.; Crudder, C. H.; Wilmoth, J. L.; Stevens, D. S.; Mora-Garcia, S.; Yanovsky, M. J.; Weigl, B. H.; Yanovsky, J.

    2011-01-01

    Improved diagnostic tests for Chagas disease are urgently needed. A new lateral flow rapid test for Chagas disease is under development at PATH, in collaboration with Laboratorio Lemos of Argentina, which utilizes a recombinant antigen for detection of antibodies to Trypanosoma cruzi. To evaluate the performance of this test, 375 earlier characterized serum specimens from a region where Chagas is endemic were tested using a reference test (the Ortho T. cruzi ELISA, Johnson & Johnson), a commercially available rapid test (Chagas STAT-PAK, Chembio), and the PATH–Lemos rapid test. Compared to the composite reference tests, the PATH–Lemos rapid test demonstrated an optimal sensitivity of 99.5% and specificity of 96.8%, while the Chagas STAT-PAK demonstrated a sensitivity of 95.3% and specificity of 99.5%. These results indicate that the PATH–Lemos rapid test shows promise as an improved and reliable tool for screening and diagnosis of Chagas disease. PMID:21342808

  2. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa.

    Directory of Open Access Journals (Sweden)

    Ziningi Jaya

    Full Text Available Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC clinics in rural KwaZulu-Natal (KZN, South Africa.We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic's compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor. A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05.Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2% of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics' average rating score for compliance to the WHO guidelines ranged

  3. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Jaya, Ziningi; Drain, Paul K; Mashamba-Thompson, Tivani P

    2017-01-01

    Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic's compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor). A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05. Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2%) of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics' average rating score for compliance to the WHO guidelines ranged between 64.4% (CI

  4. Evaluation of three commercial rapid tests for detecting antibodies to human immunodeficiency virus.

    Science.gov (United States)

    Ng, K P; Saw, T L; Baki, A; Kamarudin, R

    2003-08-01

    Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest are simple/rapid tests for the detection of antibodies to HIV-1 and HIV-2 in human whole blood, serum and plasma samples. The assay is one step and the result is read visually within 15 minutes. Using 92 known HIV-1 reactive sera and 108 known HIV-1 negative sera, the 3 HIV tests correctly identified all the known HIV-1 reactive and negative samples. The results indicated that Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest HIV are as sensitive and specific (100% concordance) as Microparticle Enzyme Immunoassay. The data indicated that these 3 HIV tests are effective testing systems for diagnosis of HIV infection in a situation when the conventional Enzyme Immunoassay is not suitable.

  5. Evaluation of four rapid tests for diagnosis and differentiation of HIV-1 and HIV-2 infections in Guinea-Conakry, West Africa.

    OpenAIRE

    Chaillet, Pascale; Tayler-Smith, Katie; Zachariah, Rony; Duclos, Nanfack; Moctar, Diallo; Beelaert, Greet; Fransen, Katrien

    2010-01-01

    With both HIV-1 and HV-2 prevalent in Guinea-Conakry, accurate diagnosis and differentiation is crucial for treatment purposes. Thus, four rapid HIV tests were evaluated for their HIV-1 and HIV-2 diagnostic and discriminative capacity for use in Guinea-Conakry. These included SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), Genie II HIV1/HIV2 (Bio-Rad), First Response HIV Card Test 1-2.0 (PMC Medical) and Immunoflow HIV1-HIV2 (Core Diagnostics). Results were compared with gold standard tes...

  6. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis

    Directory of Open Access Journals (Sweden)

    Kumara V. Nibhanipudi MD

    2015-08-01

    Full Text Available Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Results: Total number is 100. Cultures 9(+; for rapid strep== 84(- and16 (+; For LE== 80(- and 20(+ Statistics: From data configuration Rapid Strep versus LE test don’t seem to be a random (independent assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001 reject Null Hypothesis and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.

  7. Evaluation of the BYG Carba Test, a New Electrochemical Assay for Rapid Laboratory Detection of Carbapenemase-Producing Enterobacteriaceae

    Science.gov (United States)

    Yunus, Sami; Massart, Marion; Huang, Te-Din; Glupczynski, Youri

    2015-01-01

    Accurate detection of carbapenemase-producing Enterobacteriaceae (CPE) constitutes a major laboratory diagnostic challenge. We evaluated an electrochemical technique (the BYG Carba test) which allows detection of CPE in less than 35 min. The BYG Carba test was first validated in triplicate against 57 collection isolates with previously characterized β-lactam resistance mechanisms (OXA-48, n = 12; KPC, n = 8; NDM, n = 8; VIM, n = 8; IMP, n = 3; GIM, n = 1; GES-6, n = 1; no carbapenemase, n = 16) and against a panel of 10 isolates obtained from the United Kingdom National External Quality Assessment Service (NEQAS). The test was then evaluated prospectively against 324 isolates referred to the national reference center for suspicion of CPE. The BYG Carba test results were compared with those obtained with the Carba NP test using multiplex PCR sequencing as the gold standard. Of the 57 collection and the 10 NEQAS isolates, all but one GES-6-producing isolate were correctly identified by the Carba BYG test. Among the 324 consecutive Enterobacteriaceae isolates tested prospectively, 146 were confirmed as noncarbapenemase producers by PCR while 178 harbored a carbapenemase gene (OXA-48, n = 117; KPC, n = 25; NDM, n = 23; and VIM, n = 13). Prospectively, in comparison with PCR results, the BYG Carba test displayed 95% sensitivity and 100% specificity versus 89% and 100%, respectively, for the Carba NP test. The BYG Carba test is a novel, rapid, and efficient assay based on an electro-active polymer biosensing technology discriminating between CPE and non-CPE. The precise electrochemical signal (electrochemical impedance variations) allows the establishment of real-time objective measurement and interpretation criteria which should facilitate the accreditation process of this technology. PMID:26637378

  8. An assessment of the usefulness of a rapid immuno-chromatographic test, "Determine™ malaria pf" in evaluation of intervention measures in forest villages of central India

    Directory of Open Access Journals (Sweden)

    Shukla Manmohan

    2001-08-01

    Full Text Available Abstract Background Plasmodium falciparum malaria, is a major health problem in forested tribal belt of central India. Rapid and accurate methods are needed for the diagnosis of P. falciparum. We performed a blinded evaluation of the recently introduced Determine™ malaria pf test (Abbott, Laboratories, Japan compared with microscopy and splenomegaly in children in epidemic prone areas of district Mandla to assess the impact of intervention measures. Methods Children aged 2–10 yrs with and without fever were examined for spleen enlargement by medical specialist by establishing a mobile field clinic. From these children thick blood smears were prepared from finger prick and read by a technician. Simultaneously, rapid tests were performed by a field lab attendant. The figures for specificity, sensitivity and predictive values were calculated using microscopy as gold standard. Results In all 349 children were examined. The sensitivity and specificity for Determine rapid diagnostic test were 91 and 80% respectively. The positive predictive values (PPV, negative predictive values (NPV and accuracy of the test were respectively 79, 91 and 85%. On the contrary, the sensitivity and specificity of spleen in detecting malaria infection were 57 and 74 % respectively with PPV of 73%, NPV 59 % and an accuracy of 65%. Conclusions Determine™ malaria rapid diagnostic test is easier and quicker to perform and has other advantages over microscopy in not requiring prior training of personnel or quality control. Thus, highlighting the usefulness of a rapid antigen test in assessing prevailing malaria situation in remote areas.

  9. Evaluation of HIV-1 rapid tests and identification of alternative testing algorithms for use in Uganda.

    Science.gov (United States)

    Kaleebu, Pontiano; Kitandwe, Paul Kato; Lutalo, Tom; Kigozi, Aminah; Watera, Christine; Nanteza, Mary Bridget; Hughes, Peter; Musinguzi, Joshua; Opio, Alex; Downing, Robert; Mbidde, Edward Katongole

    2018-02-27

    The World Health Organization recommends that countries conduct two phase evaluations of HIV rapid tests (RTs) in order to come up with the best algorithms. In this report, we present the first ever such evaluation in Uganda, involving both blood and oral based RTs. The role of weak positive (WP) bands on the accuracy of the individual RT and on the algorithms was also investigated. In total 11 blood based and 3 oral transudate kits were evaluated. All together 2746 participants from seven sites, covering the four different regions of Uganda participated. Two enzyme immunoassays (EIAs) run in parallel were used as the gold standard. The performance and cost of the different algorithms was calculated, with a pre-determined price cut-off of either cheaper or within 20% price of the current algorithm of Determine + Statpak + Unigold. In the second phase, the three best algorithms selected in phase I were used at the point of care for purposes of quality control using finger stick whole blood. We identified three algorithms; Determine + SD Bioline + Statpak; Determine + Statpak + SD Bioline, both with the same sensitivity and specificity of 99.2% and 99.1% respectively and Determine + Statpak + Insti, with sensitivity and specificity of 99.1% and 99% respectively as having performed better and met the cost requirements. There were 15 other algorithms that performed better than the current one but rated more than the 20% price. None of the 3 oral mucosal transudate kits were suitable for inclusion in an algorithm because of their low sensitivities. Band intensity affected the performance of individual RTs but not the final algorithms. We have come up with three algorithms we recommend for public or Government procurement based on accuracy and cost. In case one algorithm is preferred, we recommend to replace Unigold, the current tie breaker with SD Bioline. We further recommend that all the 18 algorithms that have shown better performance than the current one are made

  10. Rapid pile load tests in the geotechnical centrifuge

    NARCIS (Netherlands)

    Holscher, P.; Van Tol, A.F.; Huy, N.Q.

    2012-01-01

    Centrifiige experiments were carried out to gain insight into the factors that affect the mobilized resistance during rapid load testing on piles in sand. The influence of generated pore water pressure during rapid load tests is shidied, and its effect on the commonly used unloadmg point method to

  11. Impact of the rapid antigen detection test in diagnosis and treatment of acute pharyngotonsillitis in a pediatric emergency room.

    Science.gov (United States)

    Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E

    2013-01-01

    To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.

  12. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study.

    Science.gov (United States)

    Shimelis, Techalew; Tadesse, Endale

    2015-04-23

    To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. A hospital-based cross-sectional study. This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. An evaluation of the Oxoid Biochemical Identification System Campy rapid screening test for Campylobacteraceae and Helicobacter spp.

    Science.gov (United States)

    Hoosain, N; Lastovica, A J

    2009-06-01

    To evaluate the Oxoid Biochemical Identification System (OBIS) Campy test (ID0800M) against Campylobacter; Arcobacter; and other micro-organisms, with similar colonial morphology, for the detection of l-alanine aminopeptidase (l-ALA). The KOH and l-ALA (OBIS and Fluka) tests were carried out on every isolate. The procedures were followed as indicated in the OBIS and Fluka kit instructions. A total of 146 strains of 19 species of Campylobacter, seven strains of Arcobacter butzleri, four Arcobacter butzleri-like strains, 42 strains of 10 species of Helicobacter, 96 Gram-negative and 49 Gram-positive clinical isolates were tested. As expected, Campylobacter and Arcobacter strains were negative, while other Gram-negative bacteria were positive for the l-ALA test. An unexpected finding was that Helicobacter strains, although Gram-negative, were all negative for the l-ALA tests suggesting the absence of l-ALA within this genus. This is a novel finding. The absence of l-ALA was confirmed upon comparison with the available full genomic sequences of Helicobacter on the NCBI database. The OBIS Campy (ID0800M) test kit proved to be rapid and accurate for the presumptive characterization of Campylobacter and Arcobacter. A novel finding was that Helicobacter species also did not have the l-ALA enzyme. The OBIS kit will be useful in diagnostic laboratories for the presumptive diagnosis of Campylobacter, Arcobacter and Helicobacter strains.

  14. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-05-26

    rates in the study populations ranged from 1% to 75% (median prevalence 24%, interquartile range (IQR) 11% to 46%). The included studies evaluated 16 different RDTs, and 16 studies compared two or more different RDTs. Only three studies used the Grade 1 reference standard, and only 11 studies recruited unselected febrile patients. Most included studies were from Asia, with five studies from sub-Saharan Africa. All of the RDTs were designed to detect S.Typhi infection only.Most studies evaluated three RDTs and their variants: TUBEX in 14 studies; Typhidot (Typhidot, Typhidot-M, and TyphiRapid-Tr02) in 22 studies; and the Test-It Typhoid immunochromatographic lateral flow assay, and its earlier prototypes (dipstick, latex agglutination) developed by the Royal Tropical Institute, Amsterdam (KIT) in nine studies. Meta-analyses showed an average sensitivity of 78% (95% confidence interval (CI) 71% to 85%) and specificity of 87% (95% CI 82% to 91%) for TUBEX; and an average sensitivity of 69% (95% CI 59% to 78%) and specificity of 90% (95% CI 78% to 93%) for all Test-It Typhoid and prototype tests (KIT). Across all forms of the Typhidot test, the average sensitivity was 84% (95% CI 73% to 91%) and specificity was 79% (95% CI 70% to 87%). When we based the analysis on the 13 studies of the Typhidot test that either reported indeterminate test results or where the test format means there are no indeterminate results, the average sensitivity was 78% (95% CI 65% to 87%) and specificity was 77% (95% CI 66% to 86%). We did not identify any difference in either sensitivity or specificity between TUBEX, Typhidot, and Test-it Typhoid tests when based on comparison to the 13 Typhidot studies where indeterminate results are either reported or not applicable. If TUBEX and Test-it Typhoid are compared to all Typhidot studies, the sensitivity of Typhidot was higher than Test-it Typhoid (15% (95% CI 2% to 28%), but other comparisons did not show a difference at the 95% level of CIs.In a

  15. The microdose rapid 14C urea breath test compares well with the original rapid 14 breath test

    International Nuclear Information System (INIS)

    Bellon, M.S.; Bartholomeusz, F.D.L.; Chatterton, B.E.

    2000-01-01

    Full text: The 14 C urea breath test (CUBT) is a sensitive test used in the detection of H. pylori infection. The rapid 14 CUBT using 185 KBq of 14 C urea showed a sensitivity of 100% when tested in 36 patients. The aim of this study was to compare the results of the 14 CUBT performed following the ingestion of 37KBq microdose 14 C urea capsule (Bicapsule, Trimed) with the earlier method which uses 185 KBq 14 C urea. 19 patients (nine female age 21-52 yrs) were studied. All subjects first underwent a 14 CUBT with the microdose capsule and a single 15 minute post ingestion sample. An hour later the test was repeated but with a dose of 185 KBq 14 C urea in liquid form. A normal result was taken as 2 = 0.92). This is shown above. The Rapid 14 CUBT performed following the microdose capsule whilst reducing patient radiation exposure is an accurate test for the detection of H. pylori. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  16. HIV Rapid Testing in a VA Emergency Department Setting: Cost Analysis at 5 Years.

    Science.gov (United States)

    Knapp, Herschel; Chan, Kee

    2015-07-01

    To conduct a comprehensive cost-minimization analysis to comprehend the financial attributes of the first 5 years of an implementation wherein emergency department (ED) registered nurses administered HIV oral rapid tests to patients. A health science research implementation team coordinated with ED stakeholders and staff to provide training, implementation guidelines, and support to launch ED registered nurse-administered HIV oral rapid testing. Deidentified quantitative data were gathered from the electronic medical records detailing quarterly HIV rapid test rates in the ED setting spanning the first 5 years. Comprehensive cost analyses were conducted to evaluate the financial impact of this implementation. At 5 years, a total of 2,620 tests were conducted with a quarterly mean of 131 ± 81. Despite quarterly variability in testing rates, regression analysis revealed an average increase of 3.58 tests per quarter. Over the course of this implementation, Veterans Health Administration policy transitioned from written to verbal consent for HIV testing, serving to reduce the time and cost(s) associated with the testing process. Our data indicated salient health outcome benefits for patients with respect to the potential for earlier detection, and associated long-run cost savings. Copyright © 2015. Published by Elsevier Inc.

  17. Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testing.

    Science.gov (United States)

    Wesolowski, Laura G; MacKellar, Duncan A; Facente, Shelley N; Dowling, Teri; Ethridge, Steven F; Zhu, Julia H; Sullivan, Patrick S

    2006-08-01

    Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the

  18. The sensitivity and the specifity of rapid antigen test in streptococcal upper respiratory tract infections.

    Science.gov (United States)

    Gurol, Yesim; Akan, Hulya; Izbirak, Guldal; Tekkanat, Zuhal Tazegun; Gunduz, Tehlile Silem; Hayran, Osman; Yilmaz, Gulden

    2010-06-01

    It is aimed to detect the sensitivity and specificity of rapid antigen detection of group A beta hemolytic streptococci from throat specimen compared with throat culture. The other goal of the study is to help in giving clinical decisions in upper respiratory tract infections according to the age group, by detection of sensitivity and positive predictive values of the rapid tests and throat cultures. Rapid antigen detection and throat culture results for group A beta hemolytic streptococci from outpatients attending to our university hospital between the first of November 2005 and 31st of December 2008 were evaluated retrospectively. Throat samples were obtained by swabs from the throat and transported in the Stuart medium and Quickvue Strep A [Quidel, San Diego, USA] cassette test was applied and for culture, specimen was inoculated on 5% blood sheep agar and identified according to bacitracin and trimethoprim-sulphametaxazole susceptibility from beta hemolytic colonies. During the dates between the first of November 2005 and 31st of December 2008, from 453 patients both rapid antigen detection and throat culture were evaluated. Rapid antigen detection sensitivity and specificity were found to be 64.6% and 96.79%, respectively. The positive predictive value was 80.95% whereas negative predictive value was 92.82%. Kappa index was 0.91. When the results were evaluated according to the age groups, the sensitivity and the positive predictive value of rapid antigen detection in children were 70%, 90.3% and in adults 59.4%, 70.4%. When bacterial infection is concerned to prevent unnecessary antibiotic use, rapid streptococcal antigen test (RSAT) is a reliable method to begin immediate treatment. To get the maximum sensitivity of RSAT, the specimen collection technique used and education of the health care workers is important. While giving clinical decision, it must be taken into consideration that the sensitivity and the positive predictive value of the RSAT is quite

  19. Evaluation of three rapid oral fluid test devices on the screening of multiple drugs of abuse including ketamine.

    Science.gov (United States)

    Tang, Magdalene H Y; Ching, C K; Poon, Simon; Chan, Suzanne S S; Ng, W Y; Lam, M; Wong, C K; Pao, Ronnie; Lau, Angus; Mak, Tony W L

    2018-05-01

    Rapid oral fluid testing (ROFT) devices have been extensively evaluated for their ability to detect common drugs of abuse; however, the performance of such devices on simultaneous screening for ketamine has been scarcely investigated. The present study evaluated three ROFT devices (DrugWipe ® 6S, Ora-Check ® and SalivaScreen ® ) on the detection of ketamine, opiates, methamphetamine, cannabis, cocaine and MDMA. A liquid chromatography tandem mass spectrometry (LCMS) assay was firstly established and validated for confirmation analysis of the six types of drugs and/or their metabolites. In the field test, the three ROFT devices were tested on subjects recruited from substance abuse clinics/rehabilitation centre. Oral fluid was also collected using Quantisal ® for confirmation analysis. A total of 549 samples were collected in the study. LCMS analysis on 491 samples revealed the following drugs: codeine (55%), morphine (49%), heroin (40%), methamphetamine (35%), THC (8%), ketamine (4%) and cocaine (2%). No MDMA-positive cases were observed. Results showed that the overall specificity and accuracy were satisfactory and met the DRUID standard of >80% for all 3 devices. Ora-Check ® had poor sensitivities (ketamine 36%, methamphetamine 63%, opiates 53%, cocaine 60%, THC 0%). DrugWipe ® 6S showed good sensitivities in the methamphetamine (83%) and opiates (93%) tests but performed relatively poorly for ketamine (41%), cocaine (43%) and THC (22%). SalivaScreen ® also demonstrated good sensitivities in the methamphetamine (83%) and opiates (100%) tests, and had the highest sensitivity for ketamine (76%) and cocaine (71%); however, it failed to detect any of the 28 THC-positive cases. The test completion rate (proportion of tests completed with quality control passed) were: 52% (Ora-Check ® ), 78% (SalivaScreen ® ) and 99% (DrugWipe ® 6S). Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Rapid urease test (RUT) for evaluation of urease activity in oral bacteria in vitro and in supragingival dental plaque ex vivo.

    Science.gov (United States)

    Dahlén, Gunnar; Hassan, Haidar; Blomqvist, Susanne; Carlén, Anette

    2018-05-18

    Urease is an enzyme produced by plaque bacteria hydrolysing urea from saliva and gingival exudate into ammonia in order to regulate the pH in the dental biofilm. The aim of this study was to assess the urease activity among oral bacterial species by using the rapid urease test (RUT) in a micro-plate format and to examine whether this test could be used for measuring the urease activity in site-specific supragingival dental plaque samples ex vivo. The RUT test is based on 2% urea in peptone broth solution and with phenol red at pH 6.0. Oral bacterial species were tested for their urease activity using 100 μl of RUT test solution in the well of a micro-plate to which a 1 μl amount of cells collected after growth on blood agar plates or in broth, were added. The color change was determined after 15, 30 min, and 1 and 2 h. The reaction was graded in a 4-graded scale (none, weak, medium, strong). Ex vivo evaluation of dental plaque urease activity was tested in supragingival 1 μl plaque samples collected from 4 interproximal sites of front teeth and molars in 18 adult volunteers. The color reaction was read after 1 h in room temperature and scored as in the in vitro test. The strongest activity was registered for Staphylococcus epidermidis, Helicobacter pylori, Campylobacter ureolyticus and some strains of Haemophilus parainfluenzae, while known ureolytic species such as Streptococcus salivarius and Actinomyces naeslundii showed a weaker, variable and strain-dependent activity. Temperature had minor influence on the RUT reaction. The interproximal supragingival dental plaque between the lower central incisors (site 31/41) showed significantly higher scores compared to between the upper central incisors (site 11/21), between the upper left first molar and second premolar (site 26/25) and between the lower right second premolar and molar (site 45/46). The rapid urease test (RUT) in a micro-plate format can be used as a simple and rapid method to test urease

  1. Comparison of Xpert Flu rapid nucleic acid testing with rapid antigen testing for the diagnosis of influenza A and B.

    Science.gov (United States)

    DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A

    2012-12-01

    Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. A comparison of rapid diagnostic testing (by plasmodium lactate ...

    African Journals Online (AJOL)

    Background: The World Health Organization (WHO) considers early and rapid diagnosis as one of the strategies to control malaria. This study compared the performance of Quantitative Buffy Coat (QBC) test and the Plasmodium lactate dehydrogenase (pLDH) rapid diagnostic test (RDT) with microscopy as the gold ...

  3. Addressing unmet need for HIV testing in emergency care settings: a role for computer-facilitated rapid HIV testing?

    Science.gov (United States)

    Kurth, Ann E; Severynen, Anneleen; Spielberg, Freya

    2013-08-01

    HIV testing in emergency departments (EDs) remains underutilized. The authors evaluated a computer tool to facilitate rapid HIV testing in an urban ED. Randomly assigned nonacute adult ED patients were randomly assigned to a computer tool (CARE) and rapid HIV testing before a standard visit (n = 258) or to a standard visit (n = 259) with chart access. The authors assessed intervention acceptability and compared noted HIV risks. Participants were 56% nonWhite and 58% male; median age was 37 years. In the CARE arm, nearly all (251/258) of the patients completed the session and received HIV results; four declined to consent to the test. HIV risks were reported by 54% of users; one participant was confirmed HIV-positive, and two were confirmed false-positive (seroprevalence 0.4%, 95% CI [0.01, 2.2]). Half (55%) of the patients preferred computerized rather than face-to-face counseling for future HIV testing. In the standard arm, one HIV test and two referrals for testing occurred. Computer-facilitated HIV testing appears acceptable to ED patients. Future research should assess cost-effectiveness compared with staff-delivered approaches.

  4. Pharmacogenetics of clopidogrel: comparison between a standard and a rapid genetic testing.

    Science.gov (United States)

    Saracini, Claudia; Vestrini, Anna; Galora, Silvia; Armillis, Alessandra; Abbate, Rosanna; Giusti, Betti

    2012-06-01

    CYP2C19 variant alleles are independent predictors of clopidogrel response variability and occurrence of major adverse cardiovascular events in high-risk vascular patients on clopidogrel therapy. Increasing evidence suggests a combination of platelet function testing with CYP2C19 genetic testing may be more effective in identifying high-risk individuals for alternative antiplatelet therapeutic strategies. A crucial point in evaluating the use of these polymorphisms in clinical practice, besides test accuracy, is the cost of the genetic test and rapid availability of the results. One hundred acute coronary syndrome patients were genotyped for CYP2C19*2,*3,*4,*5, and *17 polymorphisms with two platforms: Verigene(®) and the TaqMan(®) system. Genotyping results obtained by the classical TaqMan approach and the rapid Verigene approach showed a 100% concordance for all the five polymorphisms investigated. The Verigene system had shorter turnaround time with respect to TaqMan. The cost of reagents for TaqMan genotyping was lower than that for the Verigene system, but the effective manual staff involvement and the relative cost resulted in higher cost for TaqMan than for Verigene. The Verigene system demonstrated good performance in terms of turnaround time and cost for the evaluation of the clopidogrel poor metabolizer status, giving genetic information in suitable time (206 min) for a therapeutic strategy decision.

  5. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  6. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  7. Rapid antibiotic susceptibility testing of Mycobacterium tuberculosis : Its utility in resource poor settings

    Directory of Open Access Journals (Sweden)

    Poojary A

    2006-01-01

    Full Text Available Purpose: To compare the rapid colorimetric nitrate reductase based antibiotic susceptibility (CONRAS test performed on Mycobacterium tuberculosis isolates with the conventional method i.e., the proportion method. Methods: One hundred clinical isolates of M. tuberculosis were tested for susceptibility to isoniazid (INH and rifampicin (RIF by the conventional proportion method and CONRAS in Middlebrook 7H9 liquid medium enriched with growth supplements (MB7H9S. Results: The performance of the CONRAS test was evaluated using proportion method as the gold standard. The sensitivity (ability to detect true drug resistance and specificity (ability to detect true drug susceptibility of the CONRAS test to INH was 93.75 and 98.52% and for RIF it was 96.10 and 100% respectively. The mean time for reporting was 6.3 days and the test showed excellent reproducibility. The kappa (k value for INH was 0.92 and for RIF was 0.99, indicating excellent agreement between the two methods. Conclusions: CONRAS test is a rapid and reliable method of drug susceptibility for M. tuberculosis.

  8. Analysis of the Rapid Chloride Migration test

    NARCIS (Netherlands)

    Spiesz, P.R.; Ballari, M.; Brouwers, H.J.H.; Ferreira, R. M.; Gulikers, J.; Andrade, C.

    2009-01-01

    In this study the Rapid Chloride Migration test (RCM) standardized as NT Build 492 and BAW-Merkblatt is reviewed. Since the traditional natural diffusion tests are laborious, time consuming and costly, they are not always preferred from a practical point of view. To overcome these disadvantages,

  9. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  10. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  11. A rapid method of evaluating fluoroscopic system performance

    International Nuclear Information System (INIS)

    Sprawls, P.

    1989-01-01

    This paper presents a study to develop a method for the rapid evaluation and documentation of fluoroscopic image quality. All objects contained within a conventional contrast-detail test phantom (Leeds TO-10) are displayed in an array format according to their contrast and size. A copy of the display is used as the data collection form and a permanent record of system performance. A fluoroscope is evaluated by viewing the test phantom and marking the visible objects on the display. A line drawn through the objects with minimum visibility in each size group forms a contrast-detail curve for the system. This is compared with a standard or reference line, which is in the display.Deviations in curve position are useful indicators of specific image quality problems, such as excessive noise or blurring. The use of a special object-visibility array format display makes it possible to collect data, analyze the results, and create a record of fluoroscopic performance in less than 2 minutes for each viewing mode

  12. Hepatitis B virus surface antigen and anti-hepatitis C virus rapid tests underestimate hepatitis prevalence among HIV-infected patients.

    Science.gov (United States)

    Hønge, Bl; Jespersen, S; Medina, C; Té, Ds; da Silva, Zj; Ostergaard, L; Laursen, Al; Wejse, C; Krarup, H; Erikstrup, C

    2014-10-01

    In the case of coinfection with HIV and hepatitis B virus (HBV) and/or hepatitis C virus (HCV), hepatic disease progression is often accelerated, with higher rates of liver cirrhosis and liver-related mortality. We aimed to evaluate the performance of the rapid tests used routinely to detect HBV surface antigen (HBsAg) and anti-HCV among HIV-infected patients in Guinea-Bissau. Blood samples from HIV-infected patients in Guinea-Bissau were stored after testing for HBsAg and anti-HCV with rapid tests. Samples were subsequently re-tested for HBsAg and anti-HCV in Denmark. Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended on the antigen and antibody concentrations, respectively. Sex, age, CD4 cell count and antiretroviral therapy status did not differ between false negative and true positive samples in either of the tests. The study is limited by a low number of anti-HCV positive samples. New diagnostic rapid tests should always be evaluated in the setting in which they will be used before implementation. © 2014 British HIV Association.

  13. Evaluation of a rapid immunochromatographic test for the detection of low burden Dirofilaria immitis (heartworm) in dogs and cats.

    Science.gov (United States)

    Genchi, Marco; Mangia, Carlo; Ferrari, Nicola; Loukeri, Sofia

    2018-01-01

    The performance of a rapid immunochromatographic test for the detection of Dirofilaria immitis antigens (Speed Diro™; BVT-Virbac, France) was assessed in 49 experimentally infected dogs and in 244 naturally infected animals; 142 dogs and 102 cats. In experimentally infected dogs, Speed Diro™ showed a sensitivity of 90.9% in dogs infected with one adult female worm and 100% in dogs infected with more than one female worm. Specificity was 100%. For naturally infected dogs, the Knott test and PetChek ® HTWM PF served as reference methods for microfilaremia and antigenemia, respectively. All microfilaemic dogs (55/142) were positive with Speed Diro™. Importantly, none of the 21 dogs infected with D. repens were positive. The results of Speed Diro™ for the detection of antigenemia were compared with two in-house tests, SNAP ® HTWM and Witness ® Dirofilaria, and all three tests were 100% specific and sensitive in comparison to PetChek ® HTWM PF. For the evaluation of feline samples, 102 cats were examined by echocardiography. Sera from 87 heartworm-infected cats were tested by Speed Diro™ and SNAP ® HTWM. The results of Speed Diro™ were equivalent to SNAP ® HTWM, with a sensitivity of 98.9% and a specificity of 100%.

  14. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  15. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    Science.gov (United States)

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  16. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  17. Evaluation of repeatability of Kansas test method KT-73, "density, absorption and voids in hardened concrete," boil test.

    Science.gov (United States)

    2015-06-01

    For years, the Kansas Department of Transportation (KDOT) and concrete producers in the state have used a : Rapid Chloride Test for concrete cylinders, AASHTO T277. This test has been thought of as an appropriate quality : control test to evaluate pe...

  18. Quantitative evaluation of the disintegration of orally rapid disintegrating tablets by X-ray computed tomography.

    Science.gov (United States)

    Otsuka, Makoto; Yamanaka, Azusa; Uchino, Tomohiro; Otsuka, Kuniko; Sadamoto, Kiyomi; Ohshima, Hiroyuki

    2012-01-01

    To measure the rapid disintegration of Oral Disintegrating Tablets (ODT), a new test (XCT) was developed using X-ray computing tomography (X-ray CT). Placebo ODT, rapid disintegration candy (RDC) and Gaster®-D-Tablets (GAS) were used as model samples. All these ODTs were used to measure oral disintegration time (DT) in distilled water at 37±2°C by XCT. DTs were affected by the width of mesh screens, and degree to which the tablet holder vibrated from air bubbles. An in-vivo tablet disintegration test was performed for RDC using 11 volunteers. DT by the in-vivo method was significantly longer than that using the conventional tester. The experimental conditions for XCT such as the width of the mesh screen and degree of vibration were adjusted to be consistent with human DT values. Since DTs by the XCT method were almost the same as the human data, this method was able to quantitatively evaluate the rapid disintegration of ODT under the same conditions as inside the oral cavity. The DTs of four commercially available ODTs were comparatively evaluated by the XCT method, conventional tablet disintegration test and in-vivo method.

  19. Rapid assessment as an evaluation tool for polio national ...

    African Journals Online (AJOL)

    Rapid assessment as an evaluation tool for polio national immunisation days in Brong Ahafo region, Ghana. ... TM Akande, M Eshetu, G Bonsu ... Conclusion: Rapid assessment is a valuable tool for evaluation of NIDs; it enables timely intervention in covering missed children and helps in careful interpretation of the usual ...

  20. Older drivers and rapid deceleration events: Salisbury Eye Evaluation Driving Study.

    Science.gov (United States)

    Keay, Lisa; Munoz, Beatriz; Duncan, Donald D; Hahn, Daniel; Baldwin, Kevin; Turano, Kathleen A; Munro, Cynthia A; Bandeen-Roche, Karen; West, Sheila K

    2013-09-01

    Drivers who rapidly change speed while driving may be more at risk for a crash. We sought to determine the relationship of demographic, vision, and cognitive variables with episodes of rapid decelerations during five days of normal driving in a cohort of older drivers. In the Salisbury Eye Evaluation Driving Study, 1425 older drivers aged 67-87 were recruited from the Maryland Motor Vehicle Administration's rolls for licensees in Salisbury, Maryland. Participants had several measures of vision tested: visual acuity, contrast sensitivity, visual fields, and the attentional visual field. Participants were also tested for various domains of cognitive function including executive function, attention, psychomotor speed, and visual search. A custom created driving monitoring system (DMS) was used to capture rapid deceleration events (RDEs), defined as at least 350 milli-g deceleration, during a five day period of monitoring. The rate of RDE per mile driven was modeled using a negative binomial regression model with an offset of the logarithm of the number of miles driven. We found that 30% of older drivers had one or more RDE during a five day period, and of those, about 1/3 had four or more. The rate of RDE per mile driven was highest for those drivers drivingRDE's were more likely to have better scores in cognitive tests of psychomotor speed and visual search, and have faster brake reaction time. Further, greater average speed and maximum speed per driving segment was protective against RDE events. In conclusion, contrary to our hypothesis, older drivers who perform rapid decelerations tend to be more "fit", with better measures of vision and cognition compared to those who do not have events of rapid deceleration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Centrifuge modeling of rapid load tests with open-ended piles

    NARCIS (Netherlands)

    Nguyen, T.C.; Van Lottum, H.; Holscher, P.; Van Tol, A.F.

    2012-01-01

    Rapid and static load tests were conducted on open-ended and close-ended piles in the Deltares GeoCentriflige. hi flight, a pile was driven into the soil. Both fme-grained sand and silt beds were tested. Both the rapid and static soil resistances o f a close-ended pile were higher than the soil

  2. A retrospective evaluation of proficiency testing, and rapid HIV test ...

    African Journals Online (AJOL)

    Background: Proficiency testing (PT) has been implemented as a form of External Quality Assurance (EQA) by the National HIV Reference Laboratory in Kenya since 2007 in order to monitor and improve on the quality of HIV testing and counselling HTC services. Objective: To compare concordance between National HIV ...

  3. Metaanalysis of the Performance of a Combined Treponemal and Nontreponemal Rapid Diagnostic Test for Syphilis and Yaws.

    Science.gov (United States)

    Marks, Michael; Yin, Yue-Ping; Chen, Xiang-Sheng; Castro, Arnold; Causer, Louise; Guy, Rebecca; Wangnapi, Regina; Mitjà, Oriol; Aziz, Abdul; Castro, Rita; da Luz Martins Pereira, Filomena; Taleo, Fasihah; Guinard, Jérôme; Bélec, Laurent; Tun, Ye; Bottomley, Christian; Ballard, Ronald C; Mabey, David C W

    2016-09-01

    The human treponematoses are important causes of disease. Mother-to-child transmission of syphilis remains a major cause of stillbirth and neonatal death. There are also almost 100 000 cases of endemic treponemal disease reported annually, predominantly yaws. Rapid diagnostic tests (RDTs) would improve access to screening for these diseases. Most RDTs cannot distinguish current and previous infection. The Dual Path Platform (DPP) Syphilis Screen & Confirm test includes both a treponemal (T1) and nontreponemal (T2) component and may improve the accuracy of diagnosis. We conducted a metaanalysis of published and unpublished evaluations of the DPP-RDT for the diagnosis of syphilis and yaws. We calculated the sensitivity, specificity, and overall agreement of the test compared with reference laboratory tests. Nine evaluations, including 7267 tests, were included. Sensitivity was higher in patients with higher titer rapid plasma reagin (≥1:16) for both the T1 (98.2% vs 90.1%, P syphilis and yaws, although the sensitivity is decreased at lower antibody titers. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.

  4. Evaluation of Rapid Stain IDentification (RSID™ Reader System for Analysis and Documentation of RSID™ Tests

    Directory of Open Access Journals (Sweden)

    Pravatchai W. Boonlayangoor

    2013-08-01

    Full Text Available The ability to detect the presence of body fluids is a crucial first step in documenting and processing forensic evidence. The Rapid Stain IDentification (RSID™ tests for blood, saliva, semen and urine are lateral flow immunochromatographic strip tests specifically designed for forensic use. Like most lateral flow strips, the membrane components of the test are enclosed in a molded plastic cassette with a sample well and an observation window. No specialized equipment is required to use these tests or to score the results seen in the observation window; however, the utility of these tests can be enhanced if an electronic record of the test results can be obtained, preferably by a small hand-held device that could be used in the field under low light conditions. Such a device should also be able to “read” the lateral flow strips and accurately record the results of the test as either positive, i.e., the body fluid was detected, or negative, i.e., the body fluid was not detected. Here we describe the RSID™ Reader System—a ruggedized strip test reader unit that allows analysis and documentation of RSID™ lateral flow strip tests using pre-configured settings, and show that the RSID™ Reader can accurately and reproducibly report and record correct results from RSID™ blood, saliva, semen, and urine tests.

  5. Preliminary Results of a Multicentre Study of the UBC Rapid Test for Detection of Urinary Bladder Cancer.

    Science.gov (United States)

    Ecke, Thorsten H; Arndt, Christian; Stephan, Carsten; Hallmann, Steffen; Lux, Oliver; Otto, Thomas; Ruttloff, Jürgen; Gerullis, Holger

    2015-05-01

    UBC Rapid is a test detecting fragments of cytokeratins 8 and 18 in urine. These are cytokeratins frequently overexpressed in tumor cells. We present the first results of a multi-centre study using UBC Rapid in patients with bladder cancer and healthy controls. Clinical urine samples from 92 patients with tumors of the urinary bladder (45 low-grade and 47 high-grade tumors) and from 33 healthy controls were used. Urine samples were analyzed by the UBC Rapid point-of-care (POC) system and evaluated both visually and quantitatively using a concile Omega 100 POC reader. For visual evaluation, different thresholds of band intensity for considering a test as positive were applied. Sensitivities and specificities were calculated by contingency analyses. We found that pathological concentrations by UBC Rapid are detectable in urine of patients with bladder cancer. The calculated diagnostic sensitivity of UBC Rapid in urine was 68.1% for high-grade, but only 46.2% for low-grade tumors. The specificity was 90.9%. The area under the curve (AUC) after receiver-operated curve (ROC) analysis was 0.733. Pathological levels of UBC Rapid in urine are higher in patients with bladder cancer in comparison to the control group (pbladder cancer and controls. Further studies with a greater number of patients will show how valuable these results are. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  6. Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology.

    Science.gov (United States)

    Hayden, Randall T; Clinton, Lani K; Hewitt, Carolyn; Koyamatsu, Terri; Sun, Yilun; Jamison, Ginger; Perkins, Rosalie; Tang, Li; Pounds, Stanley; Bankowski, Matthew J

    2016-11-01

    The delayed reporting of antimicrobial susceptibility testing remains a limiting factor in clinical decision-making in the treatment of bacterial infection. This study evaluates the use of forward laser light scatter (FLLS) to measure bacterial growth for the early determination of antimicrobial susceptibility. Three isolates each (two clinical isolates and one reference strain) of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa were tested in triplicate using two commercial antimicrobial testing systems, the Vitek2 and the MicroScan MIC panel, to challenge the BacterioScan FLLS. The BacterioScan FLLS showed a high degree of categorical concordance with the commercial methods. Pairwise comparison with each commercial system serving as a reference standard showed 88.9% agreement with MicroScan (two minor errors) and 72.2% agreement with Vitek (five minor errors). FLLS using the BacterioScan system shows promise as a novel method for the rapid and accurate determination of antimicrobial susceptibility. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  7. ERP evidence for rapid hedonic evaluation of logos.

    Science.gov (United States)

    Handy, Todd C; Smilek, Daniel; Geiger, Lena; Liu, Cindy; Schooler, Jonathan W

    2010-01-01

    We know that human neurocognitive systems rapidly and implicitly evaluate emotionally charged stimuli. But what about more everyday, frequently encountered kinds of objects, such as computer desktop icons and business logos? Do we rapidly and implicitly evaluate these more prosaic visual images, attitude objects that might only engender a mild sense of liking or disliking, if at all? To address this question, we asked participants to view a set of unfamiliar commercial logos in the context of a target identification task as brain electrical responses to these objects were recorded via event-related potentials (ERPs). Following this task, participants individually identified those logos that were most liked or disliked, allowing us to then compare how ERP responses to logos varied as a function of hedonic evaluation-a procedure decoupling evaluative responses from any normative classification of the logos themselves. In Experiment 1, we found that visuocortical processing manifest a specific bias for disliked logos that emerged within the first 200 msec of stimulus onset. In Experiment 2, we replicated this effect while dissociating normative- and novelty-related influences. Taken together, our results provide direct electrophysiological evidence suggesting that we rapidly and implicitly evaluate commercial branding images at a hedonic level.

  8. Rapid point-of-care CD4 testing at mobile HIV testing sites to increase linkage to care: an evaluation of a pilot program in South Africa.

    Science.gov (United States)

    Larson, Bruce A; Schnippel, Kathryn; Ndibongo, Buyiswa; Xulu, Thembisile; Brennan, Alana; Long, Lawrence; Fox, Matthew P; Rosen, Sydney

    2012-10-01

    A mobile HIV counseling and testing (HCT) program around Johannesburg piloted the integration of point-of-care (POC) CD4 testing, using the Pima analyzer, to improve linkages to HIV care. We report results from this pilot program for patients testing positive (n = 508) from May to October 2010. We analyzed 3 primary outcomes: assignment to testing group (offered POC CD4 or not), successful follow-up (by telephone), and completed the referral visit for HIV care within 8 weeks after HIV testing if successfully followed up. Proportions for each outcome were calculated, and relative risks were estimated using a modified Poisson approach. Three hundred eleven patients were offered the POC CD4 test, and 197 patients were not offered the test. No differences in patient characteristics were observed between the 2 groups. Approximately 62.7% of patients were successfully followed up 8 weeks after HIV testing, with no differences observed between testing groups. Among those followed up, 54.4% reported completing their referral visit. Patients offered the POC CD4 test were more likely to complete the referral visit for further HIV care (relative risk 1.25, 95% confidence interval: 1.00 to 1.57). In this mobile HCT setting, patients offered POC CD4 testing as part of the HCT services were more likely to visit a referral clinic after testing, suggesting that rapid CD4 testing technology may improve linkage to HIV care. Future research can evaluate options for adjusting HCT services if POC CD4 testing was included permanently and the cost-effectiveness of the POC CD4 testing compared with other approaches for improving linkage of care.

  9. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    Michael Horsfall

    ABSTRACT: Blood samples collected from 272 volunteers in two communities of Bayelsa State in the Niger. Delta area were investigated for falciparum malaria parasite using the rapid test based on the detection of soluble antigen and laboratory microscopy test. The data showed that out of the 272 samples collected, ...

  10. Efficiency of a clinical prediction model for selective rapid testing in children with pharyngitis: A prospective, multicenter study

    NARCIS (Netherlands)

    Cohen, Jérémie F.; Cohen, Robert; Bidet, Philippe; Elbez, Annie; Levy, Corinne; Bossuyt, Patrick M.; Chalumeau, Martin

    2017-01-01

    There is controversy whether physicians can rely on signs and symptoms to select children with pharyngitis who should undergo a rapid antigen detection test (RADT) for group A streptococcus (GAS). Our objective was to evaluate the efficiency of signs and symptoms in selectively testing children with

  11. Diagnostic accuracy of the rapid urine lipoarabinomannan test for pulmonary tuberculosis among HIV-infected adults in Ghana-findings from the DETECT HIV-TB study

    DEFF Research Database (Denmark)

    Bjerrum, Stephanie; Kenu, Ernest; Lartey, Margaret

    2015-01-01

    BACKGROUND: Rapid diagnostic tests are urgently needed to mitigate HIV-associated tuberculosis (TB) mortality. We evaluated diagnostic accuracy of the rapid urine lipoarabinomannan (LAM) test for pulmonary TB and assessed the effect of a two-sample strategy. METHODS: HIV-infected adults eligible...

  12. Evaluation of repeatability of Kansas test method KT-73, "density, absorption and voids in hardened concrete," boil test : [technical summary].

    Science.gov (United States)

    2015-06-01

    For years, the Kansas Department of Transportation (KDOT) and concrete producers in : the state have used a Rapid Chloride Test for concrete cylinders, AASHTO T277. This : test has been thought of as an appropriate quality control test to evaluate pe...

  13. Test plan for preparing the Rapid Transuranic Monitoring Laboratory for field deployment

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1994-04-01

    This plan describes experimental work that will be performed during fiscal year 1994 to prepare the Rapid Transuranic Monitoring Laboratory (RTML) for routine field use by US Department of Energy (DOE) Environmental Restoration and Waste Management programs. The RTML is a mobile, field-deployable laboratory developed at the Idaho National Engineering Laboratory (INEL) that provides a rapid, cost-effective means of characterizing and monitoring radioactive waste remediation sites for low-level radioactive contaminants. Analytical instruments currently installed in the RTML include an extended-range, germanium photon analysis spectrometer with an automatic sample changer; two, large-area, ionization chamber alpha spectrometers; and four alpha continuous air monitors. The RTML was field tested at the INEL during June 1993 in conjunction with the Buried Waste Integrated Demonstration's remote retrieval demonstration. The major tasks described in this test plan are to (a) evaluate the beta detectors for use in screening soil samples for 90 Sr, (b) upgrade the alpha spectral analysis software programs, and (c) upgrade the photon spectral analysis software programs

  14. A comparison of test statistics for the recovery of rapid growth-based enumeration tests

    NARCIS (Netherlands)

    van den Heuvel, Edwin R.; IJzerman-Boon, Pieta C.

    This paper considers five test statistics for comparing the recovery of a rapid growth-based enumeration test with respect to the compendial microbiological method using a specific nonserial dilution experiment. The finite sample distributions of these test statistics are unknown, because they are

  15. Diagnosis of acute mononucleosis in emergency: comparison of rapid tests

    Directory of Open Access Journals (Sweden)

    Federica Scaggiante

    2011-09-01

    Full Text Available Epstein-Barr virus (EBV is a gammaherpesvirus that causes a number of clinical syndromes, including acute mononucleosis.Acute infection with EBV can vary widely with regard to the severity and presentation of illness, ranging from an asymptomatic infection to a serious, life-threatening version of mononucleosis with associated liver damage and splenomegaly. Additionally, other acute viral syndromes, including those caused by hepatitis viruses and cytomegalovirus (CMV, can lead to similar clinical syndromes. The variety of symptoms and the overlap with other viral infections underscore the importance of laboratory testing in the diagnosis of acute EBV-related disease.The purpose of this study was to evaluate the utility of an agglutination test for the detection of heterophile antibodies (Monotest and two EBV-specific rapid immunochromatographic tests (VCA-IgM and VCA-IgG/EBNA-IgG. Heterophile antibody determination is resulted to have not a real diagnostic utility for the low sensibility and specificity of the test. In our experience the only use of VCA-IgG/EBNA-IgG test is sufficient to discriminate between an acute mononucleosis and a past infection.

  16. EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats

    NARCIS (Netherlands)

    Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P.M.; Groschup, Martin H.; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Keulen, Van Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi

    2017-01-01

    We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity,

  17. Teste rápido para detecção da infecção pelo HIV-1 em gestantes Rapid test to detect HIV-1 infection among pregnant women

    Directory of Open Access Journals (Sweden)

    Geraldo Duarte

    2001-03-01

    Full Text Available Objetivos: avaliar os resultados do teste de diagnóstico rápido da infecção pelo HIV-1 disponibilizado pelo Ministério da Saúde, para identificação de gestantes contaminadas por este vírus. Métodos: avaliação prospectiva de 443 gestantes sem teste sorológico para HIV no pré-natal, atendidas no Departamento de Ginecologia e Obstetrícia da Faculdade de Medicina de Ribeirão Preto-Universidade de São Paulo (HCFMRP-USP, entre fevereiro e junho de 2000. As amostras destas pacientes foram submetidas ao teste rápido imunocromatográfico, sendo comparadas com ELISA e confirmadas pela aglutinação. Resultados: dentre as 443 gestantes submetidas ao teste rápido (20,1% dos partos no período, 16 apresentaram resultados positivos (3,6%. Nenhuma amostra negativa pelo teste rápido foi positiva pelo ELISA. Entretanto, das 16 amostras positivas pelo teste rápido, duas foram negativas pelos testes confirmatórios. Logo, a sensibilidade do teste rápido foi de 100,0%, especificidade 99,5%, valor preditivo positivo 87,5% e valor preditivo negativo 100,0%. Conclusões: os resultados obtidos na avaliação do teste para o diagnóstico rápido da infecção pelo HIV-1 em gestantes revelaram sensibilidade, especificidade e valores preditivos que o credenciam como recurso extremamente importante na indicação de medidas que reduzem a transmissão perinatal desse vírus.Purpose: to evaluate the results of a rapid diagnostic test for HIV-1 infection made available by the Health Ministry for the identification of pregnant women contaminated by this virus. Methods: we evaluated prospectively 443 pregnant women with no prenatal serologic anti-HIV test seen at the Department of Gynecology and Obstetrics of the Faculty of Medicine of Ribeirão Preto, University of São Paulo, from February to June, 2000. Samples from these patients were submitted to the rapid immunochromatographic test, which was compared with ELISA and submitted to a confirmatory

  18. Evaluation of pharmaceuticals removal by sewage sludge-derived adsorbents with rapid small-scale column tests

    Science.gov (United States)

    Zhang, P.; Ding, R.; Wallace, R.; Bandosz, T.

    2015-12-01

    New composite adsorbents were developed by pyrolyzing sewage sludge and fish waste (75:25 or 90:10 dry mass ratio) at 650 oC and 950 oC. Batch adsorption experiments demonstrated that the composite adsorbents were able to adsorb a wide range of organic contaminants (volatile organic compounds, pharmaceuticals and endocrine disrupting compounds (EDCs), and nitrosamine disinfection byproducts) with high capacities. Here we further examine the performance of the adsorbents for the simultaneous removal of 8 pharmaceuticals and EDCs with rapid small-scale column tests (RSSCT). Results show that the order of breakthrough in RSSCT is in general consistent with the affinity determined via batch tests. As expected, the maximum amount of adsorption for each compound obtained from RSSCT is identical to or less than that obtained from batch tests (with only one exception), due to adsorption kinetics. However, despite the very different input concentration (1 mg/L vs. 100 mg/L) and contact time (2 min empty bed contact time vs. 16 hour equilibrium time) used in RSSCT and batch tests, the maximum amount of pharmaceuticals and EDCs adsorbed under RSSCT is still about one half of that under equilibrium batch tests, validating the approach of using batch tests with much higher input concentrations to determine adsorption capacities. Results of a pilot-scale column test in a drinking water treatment plant for pharmaceuticals removal will also be presented.

  19. HIV rapid testing in the framework of an STI prevention project on a cohort of vulnerable Italians and immigrants.

    Science.gov (United States)

    Uccella, Ilaria; Petrelli, Alessio; Vescio, Maria Fenicia; De Carolis, Silvia; Fazioli, Cecilia; Pezzotti, Patrizio; Rezza, Gianni

    2017-08-01

    Uptake of HIV tests is a challenging issue in vulnerable populations including immigrants, normally using standard diagnostic tools. Objectives of this study were to evaluate the acceptability of HIV rapid test; estimate the percentage of newly HIV diagnoses and evaluate knowledge, attitudes and perception (KAP) about HIV/AIDS and other STIs in a specific set of immigrants and vulnerable population in Rome (Italy). All immigrant and Italian people, aged 16-70 years, attending the infectious disease outpatient clinic of the National Institute for Health, Migration and Poverty (INMP) in Rome (Italy), during the period December 2012 to December 2013 were enrolled. HIV rapid testing was provided for free and patients were asked to fill in a questionnaire evaluating KAP about HIV/STIs. All patients with risky sexual behaviours or with a recent diagnosis of STIs were invited to come back after 3-6 months and a post-counselling questionnaire was offered. Out of the total sample, 99.2% (n = 825) accepted the "rapid test" and 10 new HIV diagnoses were found (1.22%; 95% CI 0.58%-2.22%). Three hundred and eighty-five participants (47%) answered the entry questionnaire and 58 (15%) completed the follow-up. Overall, we found high knowledge about HIV/AIDS; however, lower educational level and immigrant status were associated with poor knowledge about HIV, other STIs and prevention methods. Immigrants have lower perception of sexual risk and higher prejudice than Italians. Our study showed high acceptance of rapid test in this specific vulnerable population and this allowed to identify new HIV diagnoses in unaware people. Socioeconomic inequalities observed in the KAP questionnaire suggest the need for actions to support the reduction of cultural differences in knowledge of HIV/AIDS and for policies aimed at improving access to health services and preventions programmes of marginalized populations.

  20. GSMA: Gene Set Matrix Analysis, An Automated Method for Rapid Hypothesis Testing of Gene Expression Data

    Directory of Open Access Journals (Sweden)

    Chris Cheadle

    2007-01-01

    Full Text Available Background: Microarray technology has become highly valuable for identifying complex global changes in gene expression patterns. The assignment of functional information to these complex patterns remains a challenging task in effectively interpreting data and correlating results from across experiments, projects and laboratories. Methods which allow the rapid and robust evaluation of multiple functional hypotheses increase the power of individual researchers to data mine gene expression data more efficiently.Results: We have developed (gene set matrix analysis GSMA as a useful method for the rapid testing of group-wise up- or downregulation of gene expression simultaneously for multiple lists of genes (gene sets against entire distributions of gene expression changes (datasets for single or multiple experiments. The utility of GSMA lies in its flexibility to rapidly poll gene sets related by known biological function or as designated solely by the end-user against large numbers of datasets simultaneously.Conclusions: GSMA provides a simple and straightforward method for hypothesis testing in which genes are tested by groups across multiple datasets for patterns of expression enrichment.

  1. The Center For Medicare And Medicaid Innovation's blueprint for rapid-cycle evaluation of new care and payment models.

    Science.gov (United States)

    Shrank, William

    2013-04-01

    The Affordable Care Act established the Center for Medicare and Medicaid Innovation to test innovative payment and service delivery models. The goal is to reduce program expenditures while preserving or improving the quality of care provided to beneficiaries of Medicare, Medicaid, and the Children's Health Insurance Program. Central to the success of the Innovation Center is a new, rapid-cycle approach to evaluation. This article describes that approach--setting forth how the Rapid Cycle Evaluation Group aims to deliver frequent feedback to providers in support of continuous quality improvement, while rigorously evaluating the outcomes of each model tested. This article also describes the relationship between the group's work and that of the Office of the Actuary at the Centers for Medicare and Medicaid Services, which plays a central role in the assessment of new models.

  2. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  3. Comparative evaluation of bivalent malaria rapid diagnostic tests versus traditional methods in field with special reference to heat stability testing in Central India.

    Directory of Open Access Journals (Sweden)

    Neeru Singh

    Full Text Available Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.This study was undertaken in four forested districts of central India (July, 2011- March, 2012. All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9-98.8 and lowest sensitivity was 76% (95% CI; 71.7-79.6. For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9 and 20% (95% CI; 15.6-24.5 respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6-0.9.This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.

  4. Detection of gonococcal infection : pros and cons of a rapid test.

    Science.gov (United States)

    Vickerman, Peter; Peeling, Rosanna W; Watts, Charlotte; Mabey, David

    2005-01-01

    WHO estimates that 62 million cases of gonorrhea occur annually worldwide. Untreated infection can cause serious long-term complications, especially in women. In addition, Neisseria gonorrheae infection can facilitate HIV transmission, and babies born to infected mothers are at risk of ocular infection, which can lead to blindness. Where diagnostic facilities are lacking, gonorrhea can be treated syndromically. However, this inevitably leads to over-treatment, especially in women in whom the syndrome of vaginal discharge may be due not to N. gonorrheae infection but to several other more prevalent conditions. Over-treatment is a major concern because of widespread N. gonorrheae antibiotic resistance. Moreover, a high proportion of gonorrhea cases are asymptomatic and so do not present for syndromic management. Such cases will only be detected by screening tests. The gold standard test for the detection of N. gonorrheae is culture, which has high sensitivity and specificity. However, it requires well trained staff and its performance is affected by specimen transport conditions. Other options include microscopy and tests that detect gonococcal antigen or nucleic acid. Nucleic acid amplification tests (NAATs) have higher sensitivity and can be used on non-invasive samples (urine). However, they can cross-react with other Neisseria species and are expensive, requiring highly trained staff and sophisticated equipment. In settings where patients are asked to return for laboratory results, some infected patients never receive treatment as they fail to return for their test results. This reduction in treatment, and the possible onward transmission of N. gonorrheae during any delay in treatment, means that a rapid test of lower sensitivity may be more effective if it results in patients being treated at the initial visit. Indeed, even with the low sensitivity of currently available rapid tests (50-70%), modeling shows that they can outperform gold standard tests in

  5. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  6. Evaluation of four rapid tests for diagnosis and differentiation of HIV-1 and HIV-2 infections in Guinea-Conakry, West Africa.

    Science.gov (United States)

    Chaillet, Pascale; Tayler-Smith, Katie; Zachariah, Rony; Duclos, Nanfack; Moctar, Diallo; Beelaert, Greet; Fransen, Katrien

    2010-09-01

    With both HIV-1 and HV-2 prevalent in Guinea-Conakry, accurate diagnosis and differentiation is crucial for treatment purposes. Thus, four rapid HIV tests were evaluated for their HIV-1 and HIV-2 diagnostic and discriminative capacity for use in Guinea-Conakry. These included SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), Genie II HIV1/HIV2 (Bio-Rad), First Response HIV Card Test 1-2.0 (PMC Medical) and Immunoflow HIV1-HIV2 (Core Diagnostics). Results were compared with gold standard tests (INNO-LIA HIV-I/II Score) and NEW LAV BLOT II (Bio-Rad). Four hundred and forty three sequential stored HIV-positive serum samples, of known HIV-type, were evaluated. Genie II HIV1/HIV2, Immunoflow HIV1-HIV2 and SD Bioline HIV 1/2 3.0 had 100% sensitivity (95% CI, 98.9-100%) while for First Response HIV Card Test 1-2.0 this was 99.5% (95% CI, 98.2%-99.9%). In terms of discriminatory capacity, Genie II HIV1/HIV2 identified 382/ 384(99.5%) HIV-1 samples, 49/ 52(95%) HIV-2 and 7/7(100%) HIV-positive untypable samples. Immunoflow HIV1-HIV2 identified 99% HIV-1, 67% HIV-2 and all HIV-positive untypable samples. First Response HIV Card Test 1-2.0 identified 94% HIV-1, 64% HIV-2 and 57% HIV-positive untypable samples. SD-Bioline HIV 1/2 3.0 was the worst overall performer identifying 65% HIV-1, 69% HIV-2 and all HIV-positive untypable samples. The use of SD Bioline HIV 1/2 3.0 (the current standard in Guinea-Conakry) as a discriminatory HIV test is poor and may be best replaced by Immunoflow HIV1-HIV2. Copyright 2010 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  7. Rapid Structural Design Change Evaluation with AN Experiment Based FEM

    Science.gov (United States)

    Chu, C.-H.; Trethewey, M. W.

    1998-04-01

    The work in this paper proposes a dynamic structural design model that can be developed in a rapid fashion. The approach endeavours to produce a simplified FEM developed in conjunction with an experimental modal database. The FEM is formulated directly from the geometry and connectivity used in an experimental modal test using beam/frame elements. The model sacrifices fine detail for a rapid development time. The FEM is updated at the element level so the dynamic response replicates the experimental results closely. The physical attributes of the model are retained, making it well suited to evaluate the effect of potential design changes. The capabilities are evaluated in a series of computational and laboratory tests. First, a study is performed with a simulated cantilever beam with a variable mass and stiffness distribution. The modal characteristics serve as the updating target with random noise added to simulate experimental uncertainty. A uniformly distributed FEM is developed and updated. The results show excellent results, all natural frequencies are within 0·001% with MAC values above 0·99. Next, the method is applied to predict the dynamic changes of a hardware portal frame structure for a radical design change. Natural frequency predictions from the original FEM differ by as much as almost 18% with reasonable MAC values. The results predicted from the updated model produce excellent results when compared to the actual hardware changes, the first five modal natural frequency difference is around 5% and the corresponding mode shapes producing MAC values above 0·98.

  8. Study on tube rupture strength evaluation method for rapid overheating

    International Nuclear Information System (INIS)

    Komine, Ryuji; Wada, Yusaku

    1998-08-01

    A sodium-water reaction derived from the single tube break in steam generator might overheat neighbor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. In the present study this phenomenon was recognized as the fracture of cylindrical tube with the large deformation due to overheating, and the evaluation method was investigated based on both of experimental and analytical approaches. The results obtained are as follows. (1) As for the nominal stress estimation, it was clarified through the experimental data and the detailed FEM elasto-plastic large deformation analysis that the formula used in conventional designs can be applied. (2) Within the overheating temperature limits of tubes, the creep effect is dominant, even if the loading time is too short. So the strain rate on the basis of JIS elevated temperature tensile test method for steels and heat-resisting alloys is too late and almost of total strain is composed by creep one. As a result the time dependent effect cannot be evaluated under JIS strain rate condition. (3) Creep tests in shorter time condition than a few minutes and tensile tests in higher strain rate condition than 10%/min of JIS are carried out for 2 1/4Cr-1Mo(NT) steel, and the standard values for tube rupture strength evaluation are formulated. (4) The above evaluation method based on both of the stress estimation and the strength standard values application is justified by using the tube burst test data under internal pressure. (5) The strength standard values on Type 321 ss is formulated in accordance with the procedure applied for 2 1/4Cr-1Mo(NT) steel. (author)

  9. A Microfluidic Channel Method for Rapid Drug-Susceptibility Testing of Pseudomonas aeruginosa.

    Directory of Open Access Journals (Sweden)

    Yoshimi Matsumoto

    Full Text Available The recent global increase in the prevalence of antibiotic-resistant bacteria and lack of development of new therapeutic agents emphasize the importance of selecting appropriate antimicrobials for the treatment of infections. However, to date, the development of completely accelerated drug susceptibility testing methods has not been achieved despite the availability of a rapid identification method. We proposed an innovative rapid method for drug susceptibility testing for Pseudomonas aeruginosa that provides results within 3 h. The drug susceptibility testing microfluidic (DSTM device was prepared using soft lithography. It consisted of five sets of four microfluidic channels sharing one inlet slot, and the four channels are gathered in a small area, permitting simultaneous microscopic observation. Antimicrobials were pre-introduced into each channel and dried before use. Bacterial suspensions in cation-adjusted Mueller-Hinton broth were introduced from the inlet slot and incubated for 3 h. Susceptibilities were microscopically evaluated on the basis of differences in cell numbers and shapes between drug-treated and control cells, using dedicated software. The results of 101 clinically isolated strains of P. aeruginosa obtained using the DSTM method strongly correlated with results obtained using the ordinary microbroth dilution method. Ciprofloxacin, meropenem, ceftazidime, and piperacillin caused elongation in susceptible cells, while meropenem also induced spheroplast and bulge formation. Morphological observation could alternatively be used to determine the susceptibility of P. aeruginosa to these drugs, although amikacin had little effect on cell shape. The rapid determination of bacterial drug susceptibility using the DSTM method could also be applicable to other pathogenic species, and it could easily be introduced into clinical laboratories without the need for expensive instrumentation.

  10. Effect of autolysis on the specificity of bovine spongiform encephalopathy rapid tests

    Directory of Open Access Journals (Sweden)

    Caramelli Maria

    2010-07-01

    Full Text Available Abstract Background Routine rapid testing for Bovine Spongiform Encephalopathy (BSE has highlighted some problems with BSE rapid test performance, the most significant being the number of initially reactive samples and the false positive results on autolyzed tissue. This point is important for BSE active surveillance in risk populations, because tissue autolysis is often unavoidable in routine cases. A robust test suitable for use on field material is therefore needed. To date, very limited information regarding the effect of autolysis on the robustness of rapid tests has been documented; therefore, the National Reference Centre for Animal Encephalopathies (CEA rapid test laboratory selected 450 autolyzed and negative brain stem samples from fallen stock bovines older than 24 months to assess the specificity of four tests approved for BSE active surveillance: Biorad TeSeE, Enfer TSE version 2.0, Prionics® Check LIA, and IDEXX Herd Check BSE Antigen Kit EIA. The samples were graded according to the degree of autolysis and then dissected into five portions, four of which randomly assigned to processing by rapid tests and one to be available for confirmatory Western blot analysis. Findings The specificity of the four systems was 100% for all three grades of autolysis, while the percentage of initially reactive results was 0.00 (95%CI 0.00-0.82, 0.22 (95%CI 0.006-1.23, 0.44 (95%CI 0.05-1.60, and 0.89 (95%CI 0.24-2.26 for the Biorad TeSeE, the Prionics® Check LIA, the IDEXX Herd Check BSE and the Enfer TSE tests, respectively. No association with the degree of autolysis could be drawn. Conclusions The present study demonstrates that the four rapid tests can be considered well-running diagnostic tools regardless of tissue quality; nevertheless, the number of initial reactive samples reported for some systems must not be underestimated in routine testing. Furthermore the compliance with the reported performance can be guaranteed only when an ongoing

  11. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    Science.gov (United States)

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  12. [Efficient and rapid non-test tube cloning of Jatropha curcas].

    Science.gov (United States)

    Wang, Zhao-Yu; Lin, Jing-Ming; Xu, Zeng-Fu

    2007-08-01

    To develop a new technique for efficient and rapid non-test tube cloning of the medicinal and energy- producing plant Jatropha curcas. Using the mini-stem fragment (2-3 cm) of Jatropha curcas with merely one axillary bud as the explant, the effect of an auxin IBA concentration on the plantlet regeneration was studied. When treated with 1 mg/LIBA for 1h, the explants showed the most rapid propagation. The mini-stem fragments high root regeneration ratio (96.7%), short root regeneration period (18.2-/+2.0 d), large number of new roots per explant (6.3-/+1.8), and long total root length (6.8-/+3.5 cm), demonstrating that this technique can be a simple and efficient method for rapid non-test tube cloning of Jatropha curcas of potential industrial value.

  13. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  14. Patho-TB test for the rapid diagnosis of pulmonary tuberculosis

    Directory of Open Access Journals (Sweden)

    Roya Alavi-Naini

    2009-09-01

    Full Text Available

    • BACKGROUND: Despite recent technologic improvements in identifying mycobacterium tuberculosis, we are still facing problems in rapid diagnosis of tuberculosis. The objective of this study is to determine the diagnostic value of a new rapid screening test (Patho-TB™ for diagnosis of pulmonary tuberculosis.
    • METHODS: Between September 2006 to August 2007, 178 patients were enrolled in the study who were finally classified into two groups; a group of documented pulmonary tuberculosis (n = 67 and a group of non-tuberculous pulmonary infection (n = 111. Patho-TB™ test, Ziehl-Neelsen staining and culture were done on all specimens.
    • RESULTS: Of all, 43 patients with pulmonary tuberculosis were sputum smear positive for acid fast bacilli and the rest were smear negative. Mean age of the patients was 59.8 ± 16.1 years and 44% of them were men. The results of Patho- TB™ test were positive in 40 of smear positive and 20 of smear negative tuberculous patients and 33 cases of nontuberculous control group. The sensitivity, specificity, positive and negative predictive values and accuracy of Patho- TB™ test were estimated 89.5%, 70.2%, 64.5%, 91.7% and 77.5%, respectively.
    • CONCLUSIONS: According to the present study it would be suggested that Patho-TB™ test could be a rapid and inexpensive method for diagnosis of pulmonary tuberculosis, given by its high sensitivity and negative predictive value. Concerning the high number of false positive results, using a confirmatory diagnostic procedure is mandatory.
    • KEYWORDS: Pulmonary Tuberculosis, Rapid Diagnosis, Mycobacterium Tuberculosis Antigens, Iran

  15. Rapid identification and antimicrobial susceptibility testing of positive blood cultures using MALDI-TOF MS and a modification of the standardised disc diffusion test: a pilot study.

    LENUS (Irish Health Repository)

    Fitzgerald, C

    2016-04-27

    In an era when clinical microbiology laboratories are under increasing financial pressure, there is a need for inexpensive, yet effective, rapid microbiology tests. The aim of this study was to evaluate a novel modification of standard methodology for the identification and antimicrobial susceptibility testing (AST) of pathogens in positive blood cultures, reducing the turnaround time of laboratory results by 24 h.

  16. Evaluation Of Algorithms Of Anti- HIV Antibody Tests

    Directory of Open Access Journals (Sweden)

    Paranjape R.S

    1997-01-01

    Full Text Available Research question: Can alternate algorithms be used in place of conventional algorithm for epidemiological studies of HIV infection with less expenses? Objective: To compare the results of HIV sero- prevalence as determined by test algorithms combining three kits with conventional test algorithm. Study design: Cross â€" sectional. Participants: 282 truck drivers. Statistical analysis: Sensitivity and specificity analysis and predictive values. Results: Three different algorithms that do not include Western Blot (WB were compared with the conventional algorithm, in a truck driver population with 5.6% prevalence of HIV â€"I infection. Algorithms with one EIA (Genetic Systems or Biotest and a rapid test (immunocomb or with two EIAs showed 100% positive predictive value in relation to the conventional algorithm. Using an algorithm with EIA as screening test and a rapid test as a confirmatory test was 50 to 70% less expensive than the conventional algorithm per positive scrum sample. These algorithms obviate the interpretation of indeterminate results and also give differential diagnosis of HIV-2 infection. Alternate algorithms are ideally suited for community based control programme in developing countries. Application of these algorithms in population with low prevalence should also be studied in order to evaluate universal applicability.

  17. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  18. Rapid screening test for gestational diabetes: public health need, market requirement, initial product design, and experimental results

    Science.gov (United States)

    Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth

    2013-03-01

    Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.

  19. Software testing for evolutionary iterative rapid prototyping

    OpenAIRE

    Davis, Edward V., Jr.

    1990-01-01

    Approved for public release; distribution unlimited. Rapid prototyping is emerging as a promising software development paradigm. It provides a systematic and automatable means of developing a software system under circumstances where initial requirements are not well known or where requirements change frequently during development. To provide high software quality assurance requires sufficient software testing. The unique nature of evolutionary iterative prototyping is not well-suited for ...

  20. Evaluation of the Field Performance of ImmunoCard STAT!® Rapid Diagnostic Test for Rotavirus in Dadaab Refugee Camp and at the Kenya-Somalia Border.

    Science.gov (United States)

    Ope, Maurice; Nyoka, Raymond; Unshur, Ahmed; Oyier, Fredrick O; Mowlid, Shafe A; Owino, Brian; Ochieng, Steve B; Okello, Charles I; Montgomery, Joel M; Wagacha, Burton; Galev, Aleksandar; Abdow, Abdikadir; Esona, Mathew D; Tate, Jacqueline; Fitter, David; Cookson, Susan T; Arunmozhi, Balajee; Marano, Nina

    2017-06-01

    AbstractRotavirus commonly causes diarrhea in children, leading to hospitalization and even death. Rapid diagnostic tests are feasible alternatives for determining rotavirus outbreaks in refugee camps that have inadequate laboratory capacity. We evaluated the field performance of ImmunoCard STAT! ® Rotavirus (ICS-RV) in Dadaab Refugee Camp and at the Kenya-Somalia border. From May to December 2014, we prospectively enrolled children aged < 5 years hospitalized with acute diarrhea, defined as ≥ 3 episodes of loose stool in 24 hours for < 7 days. Stool samples were collected and tested by trained surveillance clerks using ICS-RV per manufacturer's instructions. The field performance characteristics of ICS-RV were evaluated against the gold standard test, Premier ™ Rotaclone ® enzyme immunoassay. The operational characteristics were evaluated using World Health Organization (WHO) ASSURED criteria to determine whether ICS-RV is appropriate as a point-of-care test by administering a standard questionnaire and observing surveillance clerks performing the test. We enrolled 213 patients with a median age of 10 months (range = 1-48); 58.2% were male. A total of 71 (33.3%) and 60 (28.2%) patients tested positive for rotavirus infection by immunoassay and ICS-RV, respectively. The sensitivity, specificity, and positive and negative predictive values of ICS-RV compared with the immunoassay were 83.1% (95% confidence interval [CI] = 72.3-91.0), 99.3% (95% CI = 96.1-100), 98.3% (95% CI = 91.1-100), and 92.1% (95% CI = 86.6-95.5), respectively. The ICS-RV fulfilled the WHO ASSURED criteria for point-of-care testing. ICS-RV is a field-ready point-of-care test with good field performance and operational characteristics. It can be useful in determining rotavirus outbreaks in resource-limited settings.

  1. Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity.

    Science.gov (United States)

    Brennan, Linda M; Widder, Mark W; McAleer, Michael K; Mayo, Michael W; Greis, Alex P; van der Schalie, William H

    2016-03-07

    This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity testing of drinking water. The manuscript further describes how to run a toxicity test using the prepared biochips. A control water sample and the test water sample are mixed with pre-measured powdered media and injected into separate channels of the biochip. Impedance readings from the sensing electrodes in each of the biochip channels are measured and compared by an automated statistical software program. The screen on the ECIS instrument will indicate either "Contamination Detected" or "No Contamination Detected" within an hour of sample injection. Advantages are ease of use and rapid response to a broad spectrum of inorganic and organic chemicals at concentrations that are relevant to human health concerns, as well as the long-term stability of stored biochips in a ready state for testing. Limitations are the requirement for cold storage of the biochips and limited sensitivity to cholinesterase-inhibiting pesticides. Applications for this toxicity detector are for rapid field-portable testing of drinking water supplies by Army Preventative Medicine personnel or for use at municipal water treatment facilities.

  2. Evaluation of a rapid radiometric differentiation test for the Mycobacterium tuberculosis complex by selective inhibition with p-nitro-alpha-acetylamino-beta-hydroxypropiophenone

    International Nuclear Information System (INIS)

    Laszlo, A.; Siddiqi, S.H.

    1984-01-01

    This study is an evaluation of a rapid technique for the differentiation of the Mycobacterium tuberculosis complex from other mycobacteria, using p-nitro-alpha-acetylamino-beta- hydroxypropiophenone (NAP) as a selective inhibitory agent. A total of 416 coded cultures, 234 cultures belonging to the M. tuberculosis complex and 182 cultures belonging to 35 other mycobacterial species, were tested in two laboratories for p-nitro-alpha-acetylamino-beta- hydroxypropiophenone inhibition to concentrations of 5 and 10 micrograms of NAP per ml in Middlebrook 7H12 liquid medium. Two testing modes were compared: the indirect, in which a large bacterial inoculum was used from an isolated culture on a solid medium, and the direct, which used a small inoculum from 7H12 medium. A decrease or no increase in daily 14 CO 2 output as measured by a BACTEC system was considered evidence of inhibition. The data presented show that a concentration of 5 micrograms of NAP per ml can effectively separate the M. tuberculosis complex from other mycobacterial species in 4 to 6 days. The direct test data show that, unlike other conventional biochemical tests, it does not require a heavy inoculum of mycobacteria and can therefore be performed soon after growth is detected by the radiometric method

  3. A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiaoguang [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Department of Medical Microbiology, Harbin Medical University, Harbin 150086 (China); Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811 (Japan); Qian, Hua [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811 (Japan); Miyamoto, Fusako [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Naito, Takeshi [Laboratory of Virus Control, Institute for Virus Research, Kyoto University, 53 Kawaramachi, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Kawaji, Kumi [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Kajiwara, Kazumi [Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); JST Innovation Plaza Kyoto, Japan Science and Technology Agency, Nishigyo-ku, Kyoto 615-8245 (Japan); Hattori, Toshio [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Matsuoka, Masao [Laboratory of Virus Control, Institute for Virus Research, Kyoto University, 53 Kawaramachi, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Watanabe, Kentaro; Oishi, Shinya; Fujii, Nobutaka [Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); and others

    2012-07-27

    Highlights: Black-Right-Pointing-Pointer We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. Black-Right-Pointing-Pointer The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. Black-Right-Pointing-Pointer In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviral activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1{sub IIIB} and HIV-1{sub BaL} as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1{sub IIIB} activity, whereas fusion inhibitors showed both anti-HIV-1{sub IIIB} and anti-HIV-1{sub BaL} activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, 'phenotypic drug evaluation', may be applicable for the evaluation of various antiviral drugs in vivo.

  4. Lack of HIV infection among truck drivers in Iran using rapid HIV test

    Directory of Open Access Journals (Sweden)

    Hossain Jabbari

    2010-01-01

    Full Text Available Background: The aim of this study was to evaluate the prevalence of HIV infection in Iranian long distance truck drivers using rapid HIV test. Methods: The study included 400 consecutive participants in Bazargan city, north-west of Iran in the late 2008 and the early 2009. Results: No HIV infection was observed among these long distance truck drivers. Conclusions: Although results of this study is plausible compared to other similar studies, repeated surveys are necessary to know the trend of HIV infection in truckers in Iran.

  5. Recent Ground Hold and Rapid Depressurization Testing of Multilayer Systems

    Science.gov (United States)

    Johnson, Wesley L.

    2014-01-01

    In the development of flight insulation systems for large cryogenic orbital storage (spray on foam and multilayer insulation), testing need include all environments that are experienced during flight. While large efforts have been expended on studying, bounding, and modeling the orbital performance of the insulation systems, little effort has been expended on the ground hold and ascent phases of a mission. Historical cryogenic in-space systems that have flown have been able to ignore these phases of flight due to the insulation system being within a vacuum jacket. In the development phase of the Nuclear Mars Vehicle and the Shuttle Nuclear Vehicle, several insulation systems were evaluated for the full mission cycle. Since that time there had been minimal work on these phases of flight until the Constellation program began investigating cryogenic service modules and long duration upper stages. With the inception of the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, a specific need was seen for the data and as such, several tests were added to the Cryogenic Boil-off Reduction System liquid hydrogen test matrix to provide more data on a insulation system. Testing was attempted with both gaseous nitrogen (GN2) and gaseous helium (GHe) backfills. The initial tests with nitrogen backfill were not successfully completed due to nitrogen liquefaction and solidification preventing the rapid pumpdown of the vacuum chamber. Subsequent helium backfill tests were successful and showed minimal degradation. The results are compared to the historical data.

  6. [Evaluation of a new blood gas analysis system: RapidPoint 500(®)].

    Science.gov (United States)

    Nicolas, Thierry; Cabrolier, Nadège; Bardonnet, Karine; Davani, Siamak

    2013-01-01

    We present here evaluation of a new blood gas analysis system, RapidPoint 500(®) (Siemens Healthcare Diagnostics). The aim of this research was to compare the ergonomics and analytical performances of this analyser with those of the RapidLab 1265 for the following parameters: pH, partial oxygen pressure, partial carbon dioxide pressure, sodium, potassium, ionized calcium, lactate and the CO-oximetry parameters: hemoglobin, oxyhemoglobin, carboxyhemoglobin, methemoglobin, reduced hemoglobin, neonatal bilirubin; as well as with the Dimension Vista 500 results for chloride and glucose. The Valtec protocol, recommended by the French Society of Clinical Biology (SFBC), was used to analyze the study results. The experiment was carried out over a period of one month in the Department of medical biochemistry. One hundred sixty five samples from adult patients admitted to the ER or hospitalized in intensive care were tested. The RapidPoint 500(®) was highly satisfactory from an ergonomic point of view. Intra-and inter- assay coefficients of variation (CV) with the three control levels were below those recommended by the SFBC for all parameters, and the comparative study gave coefficients of determination higher than 0.91. Taken together, the RapidPoint 500(®) appears fully satisfactory in terms of ergonomics and analytical performance.

  7. Evaluation of Performance of Two Rapid Tests for Detection of HIV-1 and -2 in High- and Low-Prevalence Populations in Nigeria.

    Science.gov (United States)

    Manak, Mark M; Njoku, Ogbonnaya S; Shutt, Ashley; Malia, Jennifer; Jagodzinski, Linda L; Milazzo, Mark; Suleiman, Aminu; Ogundeji, Amos A; Nelson, Robert; Ayemoba, Ojor R; O'Connell, Robert J; Singer, Darrell E; Michael, Nelson L; Peel, Sheila A

    2015-11-01

    The availability of reliable human immunodeficiency virus types 1 and 2 (HIV-1/2) rapid tests in resource-limited settings represents an important advancement in the accurate diagnosis of HIV infection and presents opportunities for implementation of effective prevention and treatment interventions among vulnerable populations. A study of the potential target populations for future HIV vaccine studies examined the prevalence of HIV infections at six selected sites in Nigeria and evaluated the use of two rapid diagnostic tests (RDTs) for HIV. The populations included market workers at sites adjacent to military installations and workers at highway settlements (truck stops) who may have a heightened risk of HIV exposure. Samples from 3,187 individuals who provided informed consent were tested in parallel using the Determine (DT) and Stat-Pak (SP) RDTs; discordant results were subjected to the Uni-Gold (UG) RDT as a tiebreaker. The results were compared to those of a third-generation enzyme immunoassay screen with confirmation of repeat reactive samples by HIV-1 Western blotting. One participant was HIV-2 infected, yielding positive results on both RDTs. Using the laboratory algorithm as a gold standard, we calculated sensitivities of 98.5% (confidence interval [CI], 97.1 to 99.8%) for DT and 98.1% (CI, 96.7 to 99.6%) for SP and specificities of 98.7% (CI, 98.3 -99.1%) for DT and 99.8% (CI, 99.6 to 100%) for SP. Similar results were obtained when the sites were stratified into those of higher HIV prevalence (9.4% to 22.8%) versus those of lower prevalence (3.2% to 7.3%). A parallel two-test algorithm requiring both DT and SP to be positive resulted in the highest sensitivity (98.1%; CI, 96.7 to 99.6%) and specificity (99.97%; CI, 99.9 to 100%) relative to those for the reference laboratory algorithm. Copyright © 2015, Manak et al.

  8. Development of a stable positive control to be used for quality assurance of rapid diagnostic tests for malaria

    NARCIS (Netherlands)

    Versteeg, Inge; Mens, Petra F.

    2009-01-01

    The objective of this study is to develop and evaluate a simple, cheap, and stable positive control for the quality control and quality assurance (QA) of rapid diagnostic tests (RDT) for the diagnosis of malaria. Plasmodium falciparum in vitro culture of known parasite concentrations was dried on a

  9. Fluoromycobacteriophages for Rapid, Specific, and Sensitive Antibiotic Susceptibility Testing of Mycobacterium tuberculosis

    Science.gov (United States)

    Piuri, Mariana; Jacobs, William R.; Hatfull, Graham F.

    2009-01-01

    Rapid antibiotic susceptibility testing of Mycobacterium tuberculosis is of paramount importance as multiple- and extensively- drug resistant strains of M. tuberculosis emerge and spread. We describe here a virus-based assay in which fluoromycobacteriophages are used to deliver a GFP or ZsYellow fluorescent marker gene to M. tuberculosis, which can then be monitored by fluorescent detection approaches including fluorescent microscopy and flow cytometry. Pre-clinical evaluations show that addition of either Rifampicin or Streptomycin at the time of phage addition obliterates fluorescence in susceptible cells but not in isogenic resistant bacteria enabling drug sensitivity determination in less than 24 hours. Detection requires no substrate addition, fewer than 100 cells can be identified, and resistant bacteria can be detected within mixed populations. Fluorescence withstands fixation by paraformaldehyde providing enhanced biosafety for testing MDR-TB and XDR-TB infections. PMID:19300517

  10. Analysis of the theoretical model of the rapid chloride migration test

    NARCIS (Netherlands)

    Spiesz, P.; Brouwers, H.J.H.; Fisher, Gregor; Geiker, Metta Rica; Hededal, Ole; Ottosen, Lisbeth M.; Stang, Henrik

    2010-01-01

    Chloride ion diffusion coefficient in concrete is estimated very often by using electromigration tests, among which the Rapid Chloride Migration (RCM) test is becoming more and more popular. Nevertheless, this test receives much criticism due to lacks in its scientific background. In this paper the

  11. The cost of implementing rapid HIV testing in sexually transmitted disease clinics in the United States.

    Science.gov (United States)

    Eggman, Ashley A; Feaster, Daniel J; Leff, Jared A; Golden, Matthew R; Castellon, Pedro C; Gooden, Lauren; Matheson, Tim; Colfax, Grant N; Metsch, Lisa R; Schackman, Bruce R

    2014-09-01

    Rapid HIV testing in high-risk populations can increase the number of persons who learn their HIV status and avoid spending clinic resources to locate persons identified as HIV infected. We determined the cost to sexually transmitted disease (STD) clinics of point-of-care rapid HIV testing using data from 7 public clinics that participated in a randomized trial of rapid testing with and without brief patient-centered risk reduction counseling in 2010. Costs included counselor and trainer time, supplies, and clinic overhead. We applied national labor rates and test costs. We calculated median clinic start-up costs and mean cost per patient tested, and projected incremental annual costs of implementing universal rapid HIV testing compared with current testing practices. Criteria for offering rapid HIV testing and methods for delivering nonrapid test results varied among clinics before the trial. Rapid HIV testing cost an average of US $22/patient without brief risk reduction counseling and US $46/patient with counseling in these 7 clinics. Median start-up costs per clinic were US $1100 and US $16,100 without and with counseling, respectively. Estimated incremental annual costs per clinic of implementing universal rapid HIV testing varied by whether or not brief counseling is conducted and by current clinic testing practices, ranging from a savings of US $19,500 to a cost of US $40,700 without counseling and a cost of US $98,000 to US $153,900 with counseling. Universal rapid HIV testing in STD clinics with same-day results can be implemented at relatively low cost to STD clinics, if brief risk reduction counseling is not offered.

  12. An evaluation of the SD Bioline HIV/syphilis duo test.

    Science.gov (United States)

    Holden, Jeffrey; Goheen, Joshua; Jett-Goheen, Mary; Barnes, Mathilda; Hsieh, Yu-Hsiang; Gaydos, Charlotte A

    2018-01-01

    Many health agencies now recommend routine HIV and syphilis testing for pregnant women and most-at-risk populations such as men who have sex with men. With the increased availability of highly sensitive, low cost rapid point-of-care tests, the ability to meet those recommendations has increased, granting wider access to quick and accurate diagnoses. Using blood specimens collected from a Baltimore City Health Department (BCHD) sexually transmitted infection clinic, we evaluated the SD Bioline HIV/Syphilis Duo, a rapid test that simultaneously detects antibodies to HIV and syphilis and has the potential to further benefit clinics and patients by reducing costs, testing complexity, and patient wait times. SD DUO HIV sensitivity and specificity, when compared to BCHD results, were 91.7 and 99.5%, respectively. SD DUO syphilis sensitivity and specificity, when compared to rapid plasma reagin, were 85.7 and 96.8%, respectively, and 69.7 and 99.7%, respectively, when compared to Treponema pallidum particle agglutination (TPPA). SD DUO syphilis sensitivity and specificity, when compared to a traditional screening algorithm, improved to 92.3 and 100%, respectively, and improved to 72.9 and 99.7%, respectively, when compared to a reverse screening algorithm. The HIV component of the SD DUO performed moderately well. However, results for the SD DUO syphilis component, when compared to TPPA, support the need for further testing and assessment.

  13. DECISION-MAKING ALIGNED WITH RAPID-CYCLE EVALUATION IN HEALTH CARE.

    Science.gov (United States)

    Schneeweiss, Sebastian; Shrank, William H; Ruhl, Michael; Maclure, Malcolm

    2015-01-01

    Availability of real-time electronic healthcare data provides new opportunities for rapid-cycle evaluation (RCE) of health technologies, including healthcare delivery and payment programs. We aim to align decision-making processes with stages of RCE to optimize the usefulness and impact of rapid results. Rational decisions about program adoption depend on program effect size in relation to externalities, including implementation cost, sustainability, and likelihood of broad adoption. Drawing on case studies and experience from drug safety monitoring, we examine how decision makers have used scientific evidence on complex interventions in the past. We clarify how RCE alters the nature of policy decisions; develop the RAPID framework for synchronizing decision-maker activities with stages of RCE; and provide guidelines on evidence thresholds for incremental decision-making. In contrast to traditional evaluations, RCE provides early evidence on effectiveness and facilitates a stepped approach to decision making in expectation of future regularly updated evidence. RCE allows for identification of trends in adjusted effect size. It supports adapting a program in midstream in response to interim findings, or adapting the evaluation strategy to identify true improvements earlier. The 5-step RAPID approach that utilizes the cumulating evidence of program effectiveness over time could increase policy-makers' confidence in expediting decisions. RCE enables a step-wise approach to HTA decision-making, based on gradually emerging evidence, reducing delays in decision-making processes after traditional one-time evaluations.

  14. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC)

    DEFF Research Database (Denmark)

    Sarkodie, F.; Hassall, O.; Owusu-Dabo, E.

    2017-01-01

    BACKGROUND: Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma...

  15. A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats

    International Nuclear Information System (INIS)

    Li, Xiaoguang; Qian, Hua; Miyamoto, Fusako; Naito, Takeshi; Kawaji, Kumi; Kajiwara, Kazumi; Hattori, Toshio; Matsuoka, Masao; Watanabe, Kentaro; Oishi, Shinya; Fujii, Nobutaka

    2012-01-01

    Highlights: ► We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. ► The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. ► In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviral activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1 IIIB and HIV-1 BaL as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1 IIIB activity, whereas fusion inhibitors showed both anti-HIV-1 IIIB and anti-HIV-1 BaL activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, “phenotypic drug evaluation”, may be applicable for the evaluation of various antiviral drugs in vivo.

  16. Evaluation of the Verigene Gram-positive blood culture nucleic acid test for rapid detection of bacteria and resistance determinants.

    Science.gov (United States)

    Wojewoda, Christina M; Sercia, Linda; Navas, Maria; Tuohy, Marion; Wilson, Deborah; Hall, Geraldine S; Procop, Gary W; Richter, Sandra S

    2013-07-01

    Rapid identification of pathogens from blood cultures can decrease lengths of stay and improve patient outcomes. We evaluated the accuracy of the Verigene Gram-positive blood culture (BC-GP) nucleic acid test for investigational use only (Nanosphere, Inc., Northbrook, IL) for the identification of Gram-positive bacteria from blood cultures. The detection of resistance genes (mecA in Staphylococcus aureus and Staphylococcus epidermidis and vanA or vanB in Enterococcus faecium and Enterococcus faecalis) by the BC-GP assay also was assessed. A total of 186 positive blood cultures (in BacT/Alert FA bottles) with Gram-positive cocci observed with Gram staining were analyzed using the BC-GP assay. The BC-GP results were compared with the identification and susceptibility profiles obtained with routine methods in the clinical laboratory. Discordant results were arbitrated with additional biochemical, cefoxitin disk, and repeat BC-GP testing. The initial BC-GP organism identification was concordant with routine method results for 94.6% of the blood cultures. Only 40% of the Streptococcus pneumoniae identifications were correct. The detection of the mecA gene for 69 blood cultures with only S. aureus or S. epidermidis was concordant with susceptibility testing results. For 3 of 6 cultures with multiple Staphylococcus spp., mecA detection was reported but was correlated with oxacillin resistance in a species other than S. aureus or S. epidermidis. The detection of vanA agreed with susceptibility testing results for 45 of 46 cultures with E. faecalis or E. faecium. Comparison of the mean times to results for each organism group showed that BC-GP results were available 31 to 42 h earlier than phenotypic identifications and 41 to 50 h earlier than susceptibility results.

  17. [Benefits of using rapid HIV testing at the PMU-FLON walk-in clinic in Lausanne].

    Science.gov (United States)

    Gilgien, W; Aubert, J; Bischoff, T; Herzig, L; Perdrix, J

    2012-05-16

    Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

  18. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  19. Modeling and evaluation of characteristics for on-street Rapid Transit systems

    DEFF Research Database (Denmark)

    Andersen, Jonas Lohmann Elkjær; Landex, Alex

    2012-01-01

    to obtain the main objective of introducing a Rapid Transit System. to increase the number of passengers. Variations in the system characteristics have a direct impact on ridership. However, it is difficult to predict the impact of implementing or altering the characteristics. A Rapid Transit system should...... display sufficient service already in the planning phase. That is why pre-acquired knowledge of the impact of the characteristics on the system performance is valuable. Such knowledge could provide a firm basis for planning the service and operation of a Rapid Transit system. This article focuses....... It focuses on the following characteristics for Rapid Transit systems: rail factor, travel time, headway and capacity. It evaluates how the implementation and variation of these characteristics affected the ridership of a case project. It evaluates the magnitude of the impacts for the various characteristics...

  20. Rapid Bedside Inactivation of Ebola Virus for Safe Nucleic Acid Tests

    DEFF Research Database (Denmark)

    Rosenstierne, Maiken Worsøe; Karlberg, Helen; Bragstad, Karoline

    2016-01-01

    Rapid bedside inactivation of Ebola virus would be a solution for the safety of medical and technical staff, risk containment, sample transport, and high-throughput or rapid diagnostic testing during an outbreak. We show that the commercially available Magna Pure lysis/binding buffer used...... for nucleic acid extraction inactivates Ebola virus. A rapid bedside inactivation method for nucleic acid tests is obtained by simply adding Magna Pure lysis/binding buffer directly into vacuum blood collection EDTA tubes using a thin needle and syringe prior to sampling. The ready-to-use inactivation vacuum...... tubes are stable for more than 4 months, and Ebola virus RNA is preserved in the Magna Pure lysis/binding buffer for at least 5 weeks independent of the storage temperature. We also show that Ebola virus RNA can be manually extracted from Magna Pure lysis/binding buffer-inactivated samples using...

  1. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    Science.gov (United States)

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.

  2. A systematic review of the clinical, public health and cost-effectiveness of rapid diagnostic tests for the detection and identification of bacterial intestinal pathogens in faeces and food.

    Science.gov (United States)

    Abubakar, I; Irvine, L; Aldus, C F; Wyatt, G M; Fordham, R; Schelenz, S; Shepstone, L; Howe, A; Peck, M; Hunter, P R

    2007-09-01

    To determine the diagnostic accuracy of tests for the rapid diagnosis of bacterial food poisoning in clinical and public health practice and to estimate the cost-effectiveness of these assays in a hypothetical population in order to inform policy on the use of these tests. Studies evaluating diagnostic accuracy of rapid tests were retrieved using electronic databases and handsearching reference lists and key journals. Hospital laboratories and test manufacturers were contacted for cost data, and clinicians involved in the care of patients with food poisoning were invited to discuss the conclusions of this review using the nominal group technique. A systematic review of the current medical literature on assays used for the rapid diagnosis of bacterial food poisoning was carried out. Specific organisms under review were Salmonella, Campylobacter, Escherichia coli O157, Staphylococcus aureus, Clostridium perfringens and Bacillus cereus. Data extraction was undertaken using standardised data extraction forms. Where a sufficient number of studies evaluating comparable tests were identified, meta-analysis was performed. A decision analytic model was developed, using effectiveness data from the review and cost data from hospitals and manufacturers, which contributed to an assessment of the cost-effectiveness of rapid tests in a hypothetical UK population. Finally, diagnostic accuracy and cost-effectiveness results were presented to a focus group of GPs, microbiologists and consultants in communicable disease control, to assess professional opinion on the use of rapid tests in the diagnosis of food poisoning. Good test performance levels were observed with rapid test methods, especially for polymerase chain reaction (PCR) assays. The estimated levels of diagnostic accuracy using the area under the curve of the summary receiver operating characteristic curve was very high. Indeed, although traditional culture is the natural reference test to use for comparative statistical

  3. Clients of sex workers in Switzerland: it makes sense to counsel and propose rapid test for HIV on the street, a preliminary report.

    Science.gov (United States)

    Diserens, Esther-Amélie; Bodenmann, Patrick; N'Garambe, Chantal; Ansermet-Pagot, Anne; Vannotti, Marco; Masserey, Eric; Cavassini, Matthias

    2010-03-19

    Clients of street sex workers may be at higher risk for HIV infection than the general population. Furthermore, there is a lack of knowledge regarding HIV testing of clients of sex workers in developed countries. This pilot study assessed the feasibility and acceptance of rapid HIV testing by the clients of street-based sex workers in Lausanne, Switzerland. For 5 evenings, clients in cars were stopped by trained field staff for face-to-face interviews focusing on sex-related HIV risk behaviors and HIV testing history. The clients were then offered a free anonymous rapid HIV test in a bus parked nearby. Rapid HIV testing and counselling were performed by experienced nurse practitioners. Clients with reactive tests were offered confirmatory testing, medical evaluation, and care in our HIV clinic. We intercepted 144 men, 112 (77.8%) agreed to be interviewed. Among them, 50 (46.6%) had never been tested for HIV. A total of 31 (27.7%) rapid HIV tests were performed, 16 (51.6%) in clients who had not previously been tested. None were reactive. Initially, 19 (16.9%) additional clients agreed to HIV testing but later declined due to the 40-minute queue for testing. This pilot study showed that rapid HIV testing in the red light district of Lausanne was feasible, and that the clients of sex workers accepted testing at an unexpectedly high rate. This setting seems particularly appropriate for targeted HIV screening, since more than 40% of the clients had not previously been tested for HIV even though they engaged in sex-related HIV risk behaviour.

  4. Detection of helicobacter pylori in nasal polyps using rapid urease test and ELISA

    Directory of Open Access Journals (Sweden)

    Masood Kaviani

    2009-01-01

    Full Text Available Introduction: Nasal polyposis is an inflammatory condition of unknown etiology. Recently concerns regarding gastroesophageal reflux or helicobacter pylori as a possible pathologic cause of nasal polyps have been increasing. The present study was planned to investigate the presence of helicobacter pylori in nasal polyps. Materials and Methods: This case-control study was undertaken enrolling 37 patients with nasal polyps who had undergone nasal endoscopic sinus surgery and 38 control subjects. Biopsy specimens of nasal polyps and inferior turbinates were assessed by rapid urease test. Blood samples of both study and control subjects were evaluated for anti H.pylori IgG by ELISA. H. pylori status was regarded positive, if both tests were positive. Results: Seropositivity was more common in the patients with nasal polyps (66.2% than control subjects (36.8% (P

  5. Evaluation of the Palutop+4 malaria rapid diagnostic test in a non-endemic setting

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2009-12-01

    Full Text Available Abstract Background Palutop+4 (All. Diag, Strasbourg, France, a four-band malaria rapid diagnostic test (malaria RDT targeting the histidine-rich protein 2 (HRP-2, Plasmodium vivax-specific parasite lactate dehydrogenase (Pv-pLDH and pan Plasmodium-specific pLDH (pan-pLDH was evaluated in a non-endemic setting on stored whole blood samples from international travellers suspected of malaria. Methods Microscopy corrected by PCR was the reference method. Samples include those infected by Plasmodium falciparum (n = 323, Plasmodium vivax (n = 97, Plasmodium ovale (n = 73 and Plasmodium malariae (n = 25 and 95 malaria negative samples. Results The sensitivities for the diagnosis of P. falciparum, P. vivax, P. malariae and P. ovale were 85.1%, 66.0%, 32.0% and 5.5%. Sensitivities increased at higher parasite densities and reached 90.0% for P. falciparum >100/μl and 83.8% for P. vivax > 500/μl. Fourteen P. falciparum samples reacted with the Pv-pLDH line, one P. vivax sample with the HRP-2 line, and respectively two and four P. ovale and P. malariae samples reacted with the HRP-2 line. Two negative samples gave a signal with the HRP-2 line. Faint and weak line intensities were observed for 129/289 (44.6% HRP-2 lines in P. falciparum samples, for 50/64 (78.1% Pv-pLDH lines in P. vivax samples and for 9/13 (69.2% pan-pLDH lines in P. ovale and P. malariae samples combined. Inter-observer reliabilities for positive and negative readings were excellent for the HRP-2 and Pv-pLDH lines (overall agreement > 92.0% and kappa-values for each pair of readers ≥ 0.88, and good for the pan-pLDH line (85.5% overall agreement and kappa-values ≥ 0.74. Conclusions Palutop+4 performed moderately for the detection of P. falciparum and P. vivax, but sensitivities were lower than those of three-band malaria RDTs.

  6. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  7. Simple and rapid field tests for brucellosis in livestock

    NARCIS (Netherlands)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L.

    2008-01-01

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the

  8. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal

    Science.gov (United States)

    Dieye, Yakou; Barrett, Kelsey L.; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B.; Guinot, Philippe; de los Santos, Tala

    2017-01-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools. PMID:28972982

  9. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Directory of Open Access Journals (Sweden)

    Yakou Dieye

    2017-10-01

    Full Text Available As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16 rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7% agreed to the rapid test while 383 (32.7% agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  10. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Science.gov (United States)

    Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala

    2017-10-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  11. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn

  12. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    Science.gov (United States)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  13. Iterative Evaluation in a Mobile Counseling and Testing Program to Reach People of Color at Risk for HIV--New Strategies Improve Program Acceptability, Effectiveness, and Evaluation Capabilities

    Science.gov (United States)

    Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles

    2011-01-01

    This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program's…

  14. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats

    Directory of Open Access Journals (Sweden)

    Jiayou Liu

    2016-09-01

    Full Text Available Objectives Feline leukemia virus (FeLV is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories, the WITNESS FeLV-FIV Test (Zoetis and the VetScan Feline FeLV/FIV Rapid Test (Abaxis. Methods The sample population (100 positive, 105 negative samples consisted of serum and plasma samples submitted to IDEXX’s worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis microtiter plate assay. Results The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%; Zoetis WITNESS (positive 79.0%, negative 97.1%; Abaxis VetScan (positive 73.0%, negative 97.1%. Conclusions and relevance The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  15. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats.

    Science.gov (United States)

    Liu, Jiayou; O'Connor, Thomas; Beall, Melissa; Chandrashekar, Ramaswamy; Lappin, Michael

    2016-01-01

    Feline leukemia virus (FeLV) is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories), the WITNESS FeLV-FIV Test (Zoetis) and the VetScan Feline FeLV/FIV Rapid Test (Abaxis). The sample population (100 positive, 105 negative samples) consisted of serum and plasma samples submitted to IDEXX's worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis) microtiter plate assay. The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%); Zoetis WITNESS (positive 79.0%, negative 97.1%); Abaxis VetScan (positive 73.0%, negative 97.1%). The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  16. Test plan for demonstration of Rapid Transuranic Monitoring Laboratory

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1993-06-01

    This plan describes tests to demonstrate the capability of the Rapid Transuranic Monitoring Laboratory (RTML) to monitor airborne alpha-emitting radionuclides and analyze soil, smear, and filter samples for alpha- and gamma-emitting radionuclides under field conditions. The RTML will be tested during June 1993 at a site adjacent to the Cold Test Pit at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. Measurement systems installed in the RTML that will be demonstrated include two large-area ionization chamber alpha spectrometers, an x-ray/gamma-ray spectrometer, and four alpha continuous air monitors. Test objectives, requirements for data quality, experimental apparatus and procedures, and safety and logistics issues are described

  17. ITERATIVE EVALUATION IN A MOBILE COUNSELING AND TESTING PROGRAM TO REACH PEOPLE OF COLOR AT RISK FOR HIV—NEW STRATEGIES IMPROVE PROGRAM ACCEPTABILITY, EFFECTIVENESS, AND EVALUATION CAPABILITIES

    Science.gov (United States)

    Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles

    2016-01-01

    This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program’s results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention’s HIV testing recommendations. PMID:21689041

  18. Rapid MRI evaluation of acute intracranial hemorrhage in pediatric head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, Maura E.; Jaju, Alok [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Ciolino, Jody D. [Northwestern University, Biostatistics Collaboration Center, Department of Preventive Medicine Feinberg School of Medicine, Chicago, IL (United States); Alden, Tord [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Neurosurgery, Chicago, IL (United States)

    2016-08-15

    Rapid MRI with ultrafast T2 sequences can be performed without sedation and is often used in place of computed tomography (CT) to evaluate pediatric patients for indications such as hydrocephalus. This study investigated the sensitivity of rapid magnetic resonance imaging (MRI) for detection and follow-up of acute intracranial hemorrhage in comparison to CT, which is commonly the first-line imaging. Patients presenting to a pediatric hospital with acute intracranial hemorrhage on CT and follow-up rapid MRI within 48 h were included. Rapid MRI studies consisted of three plane ultrafast T2 sequences either with or without axial gradient echo (GRE) sequences. Identification of hemorrhage on rapid MRI was assessed by readers both blinded and unblinded to prior CT results. One hundred two acute hemorrhages in 61 patients were identified by CT. Rapid MRI detection of subdural and epidural hemorrhages was modest in the absence of prior CT for comparison (sensitivity 61-74 %), but increased with review of the prior CT (sensitivity 80-86 %). Hemorrhage size was a significant predictor of detection (p < 0.0001). Three plane fast T2 images alone without GRE sequences were poor at detecting subarachnoid hemorrhage (sensitivity 10-25 %); rapid MRI with GRE sequences identified the majority of subarachnoid hemorrhage (sensitivity 71-93 %). GRE modestly increased detection of other extra-axial hemorrhages. Rapid MRI with GRE sequences is sensitive for most acute intracranial hemorrhages only when a prior CT is available for review. Rapid MRI is not adequate to replace CT in initial evaluation of intracranial hemorrhages but may be helpful in follow-up of known hemorrhages. (orig.)

  19. Rapid MRI evaluation of acute intracranial hemorrhage in pediatric head trauma

    International Nuclear Information System (INIS)

    Ryan, Maura E.; Jaju, Alok; Ciolino, Jody D.; Alden, Tord

    2016-01-01

    Rapid MRI with ultrafast T2 sequences can be performed without sedation and is often used in place of computed tomography (CT) to evaluate pediatric patients for indications such as hydrocephalus. This study investigated the sensitivity of rapid magnetic resonance imaging (MRI) for detection and follow-up of acute intracranial hemorrhage in comparison to CT, which is commonly the first-line imaging. Patients presenting to a pediatric hospital with acute intracranial hemorrhage on CT and follow-up rapid MRI within 48 h were included. Rapid MRI studies consisted of three plane ultrafast T2 sequences either with or without axial gradient echo (GRE) sequences. Identification of hemorrhage on rapid MRI was assessed by readers both blinded and unblinded to prior CT results. One hundred two acute hemorrhages in 61 patients were identified by CT. Rapid MRI detection of subdural and epidural hemorrhages was modest in the absence of prior CT for comparison (sensitivity 61-74 %), but increased with review of the prior CT (sensitivity 80-86 %). Hemorrhage size was a significant predictor of detection (p < 0.0001). Three plane fast T2 images alone without GRE sequences were poor at detecting subarachnoid hemorrhage (sensitivity 10-25 %); rapid MRI with GRE sequences identified the majority of subarachnoid hemorrhage (sensitivity 71-93 %). GRE modestly increased detection of other extra-axial hemorrhages. Rapid MRI with GRE sequences is sensitive for most acute intracranial hemorrhages only when a prior CT is available for review. Rapid MRI is not adequate to replace CT in initial evaluation of intracranial hemorrhages but may be helpful in follow-up of known hemorrhages. (orig.)

  20. Evaluation of Nucleic Acid Preservation Cards for West Nile Virus Testing in Dead Birds

    Science.gov (United States)

    Foss, Leslie; Reisen, William K.; Fang, Ying; Kramer, Vicki; Padgett, Kerry

    2016-01-01

    The California West Nile virus (WNV) Dead Bird Surveillance Program (DBSP) is an important component of WNV surveillance in the state. We evaluated FTA™ and RNASound™ cards as an alternative method for sampling dead birds for WNV molecular testing as these cards allow for more cost effective, rapid, and safer diagnostic sampling than the shipment of bird carcasses. To evaluate accuracy of results among avian sampling regimes, Reverse-Transcription Polymerase Chain Reaction (RT-PCR) results from FTA™ and RNASound™ cards were compared with results from kidney tissue, brain tissue, or oral swabs in lysis buffer in 2012–2013. In addition, RT-PCR results were compared with results from oral swabs tested by rapid antigen tests (RAMP™ and VecTOR™). While test results from the cards were not as sensitive as kidney tissue testing, they were more likely to provide accurate results than rapid antigen tests, and detected WNV in corvids as well as in other passerines, raptors, and waterfowl. Overall, WNV RT-PCR cycle threshold (Ct) scores from the cards were higher than those from tissue testing, but both card products displayed high sensitivity and specificity. American Crow samples provided the highest sensitivity. The cards also proved to be easier and more convenient vehicles for collecting and shipping samples, and in 2014 our program launched use of RNASound™ cards in the DBSP. Both FTA™ and RNASound™ products displayed 96% agreement with tissue results and are an adequate alternative sampling method for WNV dead bird testing. PMID:27341492

  1. Evaluation of Nucleic Acid Preservation Cards for West Nile Virus Testing in Dead Birds.

    Directory of Open Access Journals (Sweden)

    Leslie Foss

    Full Text Available The California West Nile virus (WNV Dead Bird Surveillance Program (DBSP is an important component of WNV surveillance in the state. We evaluated FTA™ and RNASound™ cards as an alternative method for sampling dead birds for WNV molecular testing as these cards allow for more cost effective, rapid, and safer diagnostic sampling than the shipment of bird carcasses. To evaluate accuracy of results among avian sampling regimes, Reverse-Transcription Polymerase Chain Reaction (RT-PCR results from FTA™ and RNASound™ cards were compared with results from kidney tissue, brain tissue, or oral swabs in lysis buffer in 2012-2013. In addition, RT-PCR results were compared with results from oral swabs tested by rapid antigen tests (RAMP™ and VecTOR™. While test results from the cards were not as sensitive as kidney tissue testing, they were more likely to provide accurate results than rapid antigen tests, and detected WNV in corvids as well as in other passerines, raptors, and waterfowl. Overall, WNV RT-PCR cycle threshold (Ct scores from the cards were higher than those from tissue testing, but both card products displayed high sensitivity and specificity. American Crow samples provided the highest sensitivity. The cards also proved to be easier and more convenient vehicles for collecting and shipping samples, and in 2014 our program launched use of RNASound™ cards in the DBSP. Both FTA™ and RNASound™ products displayed 96% agreement with tissue results and are an adequate alternative sampling method for WNV dead bird testing.

  2. Rapid-cycle testing cuts bed turnaround by 85%.

    Science.gov (United States)

    2004-11-01

    You can use rapid-cycle testing to try out new approaches to overcrowding much more frequently than with more traditional process improvement strategies. Improving bed turnaround notification can yield dramatic improvements. Telling staff they have to try a new process only for three days makes it easier to gain buy-in. Look for old policies that are no longer needed, yet continue to keep your staff bogged down.

  3. Comparison of rapid diagnostic tests to detect Mycobacterium avium subsp. paratuberculosis disseminated infection in bovine liver.

    Science.gov (United States)

    Zarei, Mehdi; Ghorbanpour, Masoud; Tajbakhsh, Samaneh; Mosavari, Nader

    2017-08-01

    Mycobacterium avium subsp. paratuberculosis (MAP) causes Johne's disease, a chronic enteritis in cattle and other domestic and wild ruminants. The presence of MAP in tissues other than intestines and associated lymph nodes, such as meat and liver, is a potential public health concern. In the present study, the relationship between the results of rapid diagnostic tests of the Johne's disease, such as serum ELISA, rectal scraping PCR, and acid-fast staining, and the presence of MAP in liver was evaluated. Blood, liver, and rectal scraping samples were collected from 200 slaughtered cattle with unknown Johne's disease status. ELISA was performed to determine the MAP antibody activity in the serum. Acid-fast staining was performed on rectal scraping samples, and PCR was performed on rectal scraping and liver samples. PCR-positive liver samples were used for mycobacterial culture. Overall, the results of this study demonstrated that MAP can be detected and cultured from liver of slaughtered cattle and rapid diagnostic tests of Johne's disease have limited value in detecting cattle with MAP infection in liver. These findings show that the presence of MAP in liver tissue may occur in cows with negative results for rapid diagnostic tests and vice versa. Hence, liver might represent another possible risk of human exposure to MAP. Given concerns about a potential zoonotic role for MAP, these results show the necessity to find new methods for detecting cattle with MAP disseminated infection.

  4. Evaluation of a new rapid diagnostic kit (FemExam) for bacterial vaginosis in patients with vaginal discharge syndrome in The Gambia

    NARCIS (Netherlands)

    West, Beryl; Morison, Linda; Schim van der Loeff, Maarten; Gooding, Euphemia; Awasana, Akum Aveika; Demba, Edward; Mayaud, Philippe

    2003-01-01

    Diagnosis of bacterial vaginosis (BV) in resource-poor primary health care settings is often overlooked; there is a need for a cheap, rapid, objective point-of-care diagnostic test. The goal was to determine the prevalence of BV and to evaluate the performance of a new commercial diagnostic test kit

  5. Hypervapotron flow testing with rapid prototype models

    International Nuclear Information System (INIS)

    Driemeyer, D.; Hellwig, T.; Kubik, D.; Langenderfer, E.; Mantz, H.; McSmith, M.; Jones, B.; Butler, J.

    1995-01-01

    A flow test model of the inlet section of a three channel hypervapotron plate that has been proposed as a heat sink in the ITER divertor was prepared using a rapid prototyping stereolithography process that is widely used for component development in US industry. An existing water flow loop at the University of Illinois is being used for isothermal flow tests to collect pressure drop data for comparison with proposed vapotron friction factor correlations. Differential pressure measurements are taken, across the test section inlet manifold, the vapotron channel (about a seven inch length), the outlet manifold and the inlet-to-outlet. The differential pressures are currently measured with manometers. Tests were conducted at flow velocities from 1--10 m/s to cover the full range of ITER interest. A tap was also added for a small hypodermic needle to inject dye into the flow channel at several positions to examine the nature of the developing flow field at the entrance to the vapotron section. Follow-on flow tests are planned using a model with adjustable flow channel dimensions to permit more extensive pressure drop data to be collected. This information will be used to update vapotron design correlations for ITER

  6. The Rapid Integration and Test Environment - A Process for Achieving Software Test Acceptance

    OpenAIRE

    Jack, Rick

    2010-01-01

    Proceedings Paper (for Acquisition Research Program) Approved for public release; distribution unlimited. The Rapid Integration and Test Environment (RITE) initiative, implemented by the Program Executive Office, Command, Control, Communications, Computers and Intelligence, Command and Control Program Office (PMW-150), was born of necessity. Existing processes for requirements definition and management, as well as those for software development, did not consistently deliver high-qualit...

  7. Multicountry Prospective Clinical Evaluation of Two Enzyme-Linked Immunosorbent Assays and Two Rapid Diagnostic Tests for Diagnosing Dengue Fever

    Science.gov (United States)

    Dauner, Allison L.; Valks, Andrea; Forshey, Brett M.; Long, Kanya C.; Thaisomboonsuk, Butsaya; Sierra, Gloria; Picos, Victor; Talmage, Sara; Morrison, Amy C.; Halsey, Eric S.; Comach, Guillermo; Yasuda, Chadwick; Loeffelholz, Michael; Jarman, Richard G.; Fernandez, Stefan; An, Ung Sam; Kochel, Tadeusz J.; Jasper, Louis E.; Wu, Shuenn-Jue L.

    2015-01-01

    We evaluated four dengue diagnostic devices from Alere, including the SD Bioline Dengue Duo (nonstructural [NS] 1 Ag and IgG/IgM), the Panbio Dengue Duo Cassette (IgM/IgG) rapid diagnostic tests (RDTs), and the Panbio dengue IgM and IgG capture enzyme-linked immunosorbent assays (ELISAs) in a prospective, controlled, multicenter study in Peru, Venezuela, Cambodia, and the United States, using samples from 1,021 febrile individuals. Archived, well-characterized samples from an additional 135 febrile individuals from Thailand were also used. Reference testing was performed on all samples using an algorithm involving virus isolation, in-house IgM and IgG capture ELISAs, and plaque reduction neutralization tests (PRNT) to determine the infection status of the individual. The primary endpoints were the clinical sensitivities and specificities of these devices. The SD Bioline Dengue Duo had an overall sensitivity of 87.3% (95% confidence interval [CI], 84.1 to 90.2%) and specificity of 86.8% (95% CI, 83.9 to 89.3%) during the first 14 days post-symptom onset (p.s.o.). The Panbio Dengue Duo Cassette demonstrated a sensitivity of 92.1% (87.8 to 95.2%) and specificity of 62.2% (54.5 to 69.5%) during days 4 to 14 p.s.o. The Panbio IgM capture ELISA had a sensitivity of 87.6% (82.7 to 91.4%) and specificity of 88.1% (82.2 to 92.6%) during days 4 to 14 p.s.o. Finally, the Panbio IgG capture ELISA had a sensitivity of 69.6% (62.1 to 76.4%) and a specificity of 88.4% (82.6 to 92.8%) during days 4 to 14 p.s.o. for identification of secondary dengue infections. This multicountry prospective study resulted in reliable real-world performance data that will facilitate data-driven laboratory test choices for managing patient care during dengue outbreaks. PMID:25588659

  8. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon

    2012-08-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  9. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon; Oh, Sang-gyun; Ha, Juyoung; Monteiro, Paulo M.

    2012-01-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  10. Application tests of a new-type LNG rapid gasification unit

    Directory of Open Access Journals (Sweden)

    Ping Yan

    2017-01-01

    Full Text Available Liquefied natural gas (LNG is stored under low temperature and high pressure. It has to be gasified before it is used. Therefore, LNG gasification unit is essential and it is vital to the high-efficiency utilization of LNG. In this paper, a new-type LNG rapid gasification unit was developed. Adopted in this unit are some innovative technologies authorized with the national patent of invention, such as the umbrella-shape gas flow circle unit, the flue gas circulation system and the water feeding system, which help to guarantee its operation safety and increase its operation efficiency. After it was justified in lab test, the unit for industrial application was designed and manufactured and then tested to verify its design rationality. The results show that the new-type LNG rapid gasification unit meets the design requirements in the aspect of efficiency, exhaust gas loss, radiation loss and fuel gas consumption rate; at a load of 1800–2200 m3/h, its efficiency is over 95%; at a load of 1976.0 m3/h which is close to the design value of 2000 m3/h, its efficiency is 96.34% or even up to 2800 m3/h. This new-type LNG rapid gasification unit is adaptable to a large range of loads and can adapt to the rapid increase of external load. Its fuel gas consumption rate is only 1.5%, which is in the range of energy conservation. It presents the advantages of high heating efficiency, rapid startup, high gasification rate, compact structure, small land occupation and invulnerability to the environment, therefore, it is applicable to the middle and small independent regions which cannot be connected to the natural gas supply pipeline networks due to various reasons.

  11. Application of Rapid Prototyping Methods to High-Speed Wind Tunnel Testing

    Science.gov (United States)

    Springer, A. M.

    1998-01-01

    This study was undertaken in MSFC's 14-Inch Trisonic Wind Tunnel to determine if rapid prototyping methods could be used in the design and manufacturing of high speed wind tunnel models in direct testing applications, and if these methods would reduce model design/fabrication time and cost while providing models of high enough fidelity to provide adequate aerodynamic data, and of sufficient strength to survive the test environment. Rapid prototyping methods utilized to construct wind tunnel models in a wing-body-tail configuration were: fused deposition method using both ABS plastic and PEEK as building materials, stereolithography using the photopolymer SL-5170, selective laser sintering using glass reinforced nylon, and laminated object manufacturing using plastic reinforced with glass and 'paper'. This study revealed good agreement between the SLA model, the metal model with an FDM-ABS nose, an SLA nose, and the metal model for most operating conditions, while the FDM-ABS data diverged at higher loading conditions. Data from the initial SLS model showed poor agreement due to problems in post-processing, resulting in a different configuration. A second SLS model was tested and showed relatively good agreement. It can be concluded that rapid prototyping models show promise in preliminary aerodynamic development studies at subsonic, transonic, and supersonic speeds.

  12. Evaluation of a rapid antigen detection test in the diagnosis of streptococcal pharyngitis in children and its impact on antibiotic prescription.

    Science.gov (United States)

    Maltezou, Helen C; Tsagris, Vasilios; Antoniadou, Anastasia; Galani, Labrini; Douros, Constantinos; Katsarolis, Ioannis; Maragos, Antonios; Raftopoulos, Vasilios; Biskini, Panagiota; Kanellakopoulou, Kyriaki; Fretzayas, Andreas; Papadimitriou, Theodoros; Nicolaidou, Polyxeni; Giamarellou, Helen

    2008-12-01

    To study the performance of the Becton-Dickinson Link 2 Strep A Rapid Test, a rapid antigen detection test (RADT) for diagnosing streptococcal pharyngitis in children presenting to private offices and to the Pediatric Outpatient Clinic of a university hospital, in relation to clinical criteria (fever, tender anterior cervical lymph nodes, tonsillar exudate and absence of cough), and its impact on antibiotic prescription. Children were enrolled in Group A (enrolment by private-practice paediatricians; diagnosis by clinical picture only), Group B (enrolment by private-practice paediatricians; diagnosis by RADT and culture) or Group C (enrolment by hospital-affiliated paediatricians in the Pediatric Outpatient Clinic; diagnosis by RADT and culture). During a 2 year period, 820 children were enrolled [369 (45%) in Group A, 270 (33%) in Group B and 181 (22%) in Group C]. Streptococcal pharyngitis was diagnosed by RADT and culture in 146 (32.4%) of the 451 tested children. The sensitivity, specificity and positive and negative predictive values of the RADT were 83.1%, 93.3%, 82.4% and 93.6%, respectively. A stepwise increase in the sensitivity of the RADT was noted among children with one, two, three or four clinical criteria (60.9% to 95.8%). Paediatricians without access to laboratory tests were more likely to prescribe antibiotics compared with paediatricians with access to tests (72.2% versus 28.2%, P antibiotics more frequently compared with hospital-affiliated paediatricians (55.7% versus 19.9%, P antibiotic administration. Such a strategy has an important impact on limiting throat culture testing and is associated with reduced antibiotic prescription.

  13. [The social marketing models and policy advices for HIV rapid testing initiated by non-govermental organization].

    Science.gov (United States)

    Liu, H; Cai, L P; Xue, H; Zhao, Y; Wu, D; Zhang, D P; Yin, W Y; Sun, J P

    2016-10-06

    Currently, a growing number of community-based organizations are providing rapid HIV testing service in various forms, some people with specific needs also purchase HIV rapid test papers through online sales channels, those imply that the demand of HIV self-test is in increasing year by year.In this paper, aims to understand the current situation of HIV rapid test led by CBOs and the approach, strategies and results of social marketing by means of expert interviews and site visits. Hope to illustrate the current situation, and make recommendations for future work.

  14. Assessing stakeholder perceptions of the acceptability and feasibility of national scale-up for a dual HIV/syphilis rapid diagnostic test in Malawi.

    Science.gov (United States)

    Maddox, Brandy L Peterson; Wright, Shauntā S; Namadingo, Hazel; Bowen, Virginia B; Chipungu, Geoffrey A; Kamb, Mary L

    2017-12-01

    The WHO recommends pregnant women receive both HIV and syphilis testing at their first antenatal care visit, as untreated maternal infections can lead to severe, adverse pregnancy outcomes. One strategy for increasing testing for both HIV and syphilis is the use of point-of-care (rapid) diagnostic tests that are simple, proven effective and inexpensive. In Malawi, pregnant women routinely receive HIV testing, but only 10% are tested for syphilis at their first antenatal care visit. This evaluation explores stakeholder perceptions of a novel, dual HIV/syphilis rapid diagnostic test and potential barriers to national scale-up of the dual test in Malawi. During June and July 2015, we conducted 15 semistructured interviews with 25 healthcare workers, laboratorians, Ministry of Health leaders and partner agency representatives working in prevention of mother-to-child transmission in Malawi. We asked stakeholders about the importance of a dual rapid diagnostic test, concerns using and procuring the dual test and recommendations for national expansion. Stakeholders viewed the test favourably, citing the importance of a dual rapid test in preventing missed opportunities for syphilis diagnosis and treatment, improving infant outcomes and increasing syphilis testing coverage. Primary technical concerns were about the additional procedural steps needed to perform the test, the possibility that testers may not adhere to required waiting times before interpreting results and difficulty reading and interpreting test results. Stakeholders thought national scale-up would require demonstration of cost-savings, uniform coordination, revisions to testing guidelines and algorithms, training of testers and a reliable supply chain. Stakeholders largely support implementation of a dual HIV/syphilis rapid diagnostic test as a feasible alternative to current antenatal testing. Scale-up will require addressing perceived barriers; negotiating changes to existing algorithms and guidelines

  15. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  17. 9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3

    Science.gov (United States)

    2010-01-01

    ...-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure described is a modification of the method reported by Schaffer, MacDonald, Hall, and Bunyea, Jour. Amer. Vet...

  18. Evaluation of a Microbial Sensor as a Tool for Antimicrobial Activity Test of Cosmetic Preservatives.

    Science.gov (United States)

    Gomyo, Hideyuki; Ookawa, Masaki; Oshibuchi, Kota; Sugamura, Yuriko; Hosokawa, Masahito; Shionoiri, Nozomi; Maeda, Yoshiaki; Matsunaga, Tadashi; Tanaka, Tsuyoshi

    2015-01-01

    For high-throughput screening of novel cosmetic preservatives, a rapid and simple assay to evaluate the antimicrobial activities should be developed because the conventional agar dilution method is time-consuming and labor-intensive. To address this issue, we evaluated a microbial sensor as a tool for rapid antimicrobial activity testing. The sensor consists of an oxygen electrode and a filter membrane that holds the test microorganisms, Staphylococcus aureus and Candida albicans. The antimicrobial activity of the tested cosmetic preservative was evaluated by measuring the current increases corresponding to the decreases in oxygen consumption in the microbial respiration. The current increases detected by the sensor showed positive correlation to the concentrations of two commercially used preservatives, chlorphenesin and 2-phenoxyethanol. The same tendency was also observed when a model cosmetic product was used as a preservative solvent, indicating the feasibility in practical use. Furthermore, the microbial sensor and microfluidic flow-cell was assembled to achieve sequential measurements. The sensor system presented in this study could be useful in large-scale screening experiments.

  19. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    Science.gov (United States)

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  20. Evaluation of OXA-48 K-Se T: an immunochromatographic assay for rapid detection of OXA-48-producing Enterobacteriaceae.

    Science.gov (United States)

    Fernández, Javier; Fleites, Ana; Rodcio, María Rosario; Vazquez, Fernando

    2016-05-01

    The OXA-48 K-Se T, a new immunochromatographic assay for rapid detection of OXA-48-producing Enterobacteriaceae, has been evaluated in a Spanish Hospital during a 3-month period. A collection of 100 Enterobacteriaceae including 79 isolates producing OXA-48 has been tested. Sensitivity and specificity of 100% were obtained. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Early warning systems and rapid response to the deteriorating patient in hospital: A realist evaluation.

    Science.gov (United States)

    McGaughey, Jennifer; O'Halloran, Peter; Porter, Sam; Trinder, John; Blackwood, Bronagh

    2017-12-01

    To test the Rapid Response Systems programme theory against actual practice components of the Rapid Response Systems implemented to identify those contexts and mechanisms which have an impact on the successful achievement of desired outcomes in practice. Rapid Response Systems allow deteriorating patients to be recognized using Early Warning Systems, referred early via escalation protocols and managed at the bedside by competent staff. Realist evaluation. The research design was an embedded multiple case study approach of four wards in two hospitals in Northern Ireland which followed the principles of Realist Evaluation. We used various mixed methods including individual and focus group interviews, observation of nursing practice between June-November 2010 and document analysis of Early Warning Systems audit data between May-October 2010 and hospital acute care training records over 4.5 years from 2003-2008. Data were analysed using NiVivo8 and SPPS. A cross-case analysis highlighted similar patterns of factors which enabled or constrained successful recognition, referral and response to deteriorating patients in practice. Key enabling factors were the use of clinical judgement by experienced nurses and the empowerment of nurses as a result of organizational change associated with implementation of Early Warning System protocols. Key constraining factors were low staffing and inappropriate skill mix levels, rigid implementation of protocols and culturally embedded suboptimal communication processes. Successful implementation of Rapid Response Systems was dependent on adopting organizational and cultural changes that facilitated staff empowerment, flexible implementation of protocols and ongoing experiential learning. © 2017 John Wiley & Sons Ltd.

  2. Evaluation of the clinical utility of a rapid blood test for human leptospirosis

    NARCIS (Netherlands)

    Eapen, C. K.; Sugathan, Sheela; Kuriakose, Mariamma; Abdoel, Theresia; Smits, Henk L.

    2002-01-01

    A rapid assay device for the detection of Leptospira-specific immunoglobulin M (IgM) antibodies was applied on whole blood samples collected from a group of consecutive patients admitted with clinical suspicion of leptospirosis to a district hospital in Kerala, India. The hospital is located in an

  3. Two rapid pigmentation tests for identification of Cryptococcus neoformans.

    Science.gov (United States)

    Kaufmann, C S; Merz, W G

    1982-01-01

    Two tests were developed for the rapid identification of Cryptococcus neoformans based on pigment produced by the organism's phenoloxidase activity. Caffeic acid was incorporated into cornmeal agar, a medium used routinely for yeast identification. When tested on this medium, only C. neoformans isolates produced brown pigment. All other yeasts maintained their normal morphology and did not produce the reaction product. A non-medium-based test was developed for same-day identification of C. neoformans isolates. Paper strips saturated with a buffered L-beta-3,4-dihydroxyphenylalanine-ferric citrate solution were inoculated with isolates and incubated at 37 degrees C. Pigment production occurred only with C. neoformans isolates, many within 60 to 90 min. All other yeasts remained negative. PMID:7040452

  4. Management of unscheduled tetanus prophylaxis in Emergency Departments: Point-of-Care implementation as a rapid tool for the evaluation of anti-tetanus antibodies

    Directory of Open Access Journals (Sweden)

    Andrea Rocchetti

    2016-03-01

    Full Text Available Background and aim: Each analytical activity, including those carried out in Point of Care (POCT must be, at law, under the control of Laboratory Medicine. Before the implementation of the rapid tetanus quick stick (TQS test for the evaluation of the specific tetanus immunisation, a multi-disciplinary and multi-professional group was created. The aim of this study was to evaluate the ability of Emergency Department (ED staff to manage and correctly understand the result of TQS test in POCT. Materials and Methods: This analysis took into consideration 152 patients admitted to ED with traumatic wounds; information on the state of tetanus immunisation at their arrival wasn’t recorded. Blood sample analysis was performed twice. The Laboratory confirmed a 100% concordance between their results and ELISA test (standard criterion. Study design consisted of 2 phases: the first one (50 test to preliminarily evaluate if any corrective action or improvement of procedures is required, and the second one (102 tests to confirm the quality of corrective actions. Results: The concordance of results between TQS test in Laboratory and POCT test in ED was 80% in the first phase and 95% in the second one.Conclusions: The use of the rapid TQS test is a valuable tool; however, to avoid serious mistakes of interpretation, periodic checks on the quality of the results must be arranged.

  5. Evaluation of the stiffness characteristics of rapid palatal expander screws

    Directory of Open Access Journals (Sweden)

    Luca Lombardo

    2016-11-01

    Full Text Available Abstract Background The aim of this study is to evaluate the mechanical properties of the screws used for rapid expansion of the upper jaw. Methods Ten types of expansion screw were assessed, seven with four arms: Lancer Philosophy 1, Dentaurum Hyrax Click Medium, Forestadent Anatomic Expander type “S”, Forestadent Anatomic Expander type “S” for narrow palates, Forestadent Memory, Leone A 2620-10 with telescopic guide, and Leone A 0630-10 with orthogonal arms; and three with two arms: Dentaurum Variety S.P., Target Baby REP Veltri, and Leone A 362113. A test expander with the mean dimensions taken from measurements on a sample of 100 expanders was constructed for each screw. The test expanders were connected to the supports of an Instron 4467 (Instron Corp., USA mechanical testing machine equipped with a 500 N load cell, and the compression force exerted after each activation was measured. The mean forces expressed by the two- and four-arm expanders were then compared. Results After five activations, the forces expressed by the two-arm devices were double than those expressed by the four-arm devices on average (224 ± 59.9 N vs. 103 ± 32.9 N, and such values remained high after subsequent activations. Conclusions The expanders tested demonstrated stiffness characteristics compatible with opening of the palatine sutures in pre-adolescent patients. The stiffness of such devices can be further increased during the construction phase.

  6. Cost-effectiveness analysis of cervical cancer prevention based on a rapid human papillomavirus screening test in a high-risk region of China.

    Science.gov (United States)

    Levin, Carol E; Sellors, John; Shi, Ju-Fang; Ma, Li; Qiao, You-lin; Ortendahl, Jesse; O'Shea, Meredith K H; Goldie, Sue J

    2010-09-01

    This study assessed the cost-effectiveness of a new, rapid human papillomavirus (HPV)-DNA screening test for cervical cancer prevention in the high-risk region of Shanxi, China. Using micro-costing methods, we estimated the resources needed to implement preventive strategies using cervical cytology or HPV-DNA testing, including the Hybrid Capture 2 (hc2) test (QIAGEN Corp., Gaithersburg, MD) and the rapid HPV-DNA careHPV test (QIAGEN). Data were used in a previously published model and empirically calibrated to country-specific epidemiological data. Strategies differed by initial test, targeted age, frequency of screening, number of clinic visits required (1, 2 or 3) and service delivery setting (national, county and township levels). Outcomes included lifetime risk of cancer, years of life saved (YLS), lifetime costs and incremental cost-effectiveness ratios (cost per YLS). For all screening frequencies, the most efficient strategy used 2-visit rapid HPV-DNA testing at the county level, including screening and diagnostics in the first visit, and treatment in the second visit. Screening at ages 35, 40 and 45 reduced cancer risk by 50% among women compliant with all 3 screening rounds, and was US$ 150 per YLS, compared with this same strategy applied twice per lifetime. This would be considered very cost-effective evaluated against China's per-capita gross domestic product (US$ 1,702). By enhancing the linkage between screening and treatment through a reduced number of visits, rapid HPV-DNA testing 3 times per lifetime is more effective than traditional cytology, and is likely to be cost-effective in high-risk regions of China.

  7. DETECTION OF RABIES VIRAL ANTIGEN IN CATTLE BY RAPID IMMUNOCHROMTOGRAPHIC DIAGNOSTIC TEST

    Directory of Open Access Journals (Sweden)

    Santanu Panda

    2016-06-01

    Full Text Available In recent years, improved quality, accuracy and speed for diagnosis of rabies has been adopted for rabies control strategies in developing countries. In field condition, rapid immunochromtographic diagnostic test (RIDT is a true requirement for rapid epidemiological surveillance of rabies. In the present study, a total of ten numbers of rabies suspected cattle brain sample form different parts of West Bengal, India were examined through RIDT. The results revealed that one sample was found to be positive. The test was established as powerful screening tool for rabies with high sensitivity and specificity. Thus, RIDT can be employed as a reliable and quick approach for diagnosis and control of rabies under field condition.

  8. Rapid diagnostic tests for diagnosing uncomplicated non-falciparum or Plasmodium vivax malaria in endemic countries

    Science.gov (United States)

    Abba, Katharine; Kirkham, Amanda J; Olliaro, Piero L; Deeks, Jonathan J; Donegan, Sarah; Garner, Paul; Takwoingi, Yemisi

    2014-01-01

    specificities are presented alongside 95% confidence intervals (95% CI). Main results We included 47 studies enrolling 22,862 participants. Patient characteristics, sampling methods and reference standard methods were poorly reported in most studies. RDTs detecting 'non-falciparum' parasitaemia Eleven studies evaluated Type 2 tests compared with microscopy, 25 evaluated Type 3 tests, and 11 evaluated Type 4 tests. In meta-analyses, average sensitivities and specificities were 78% (95% CI 73% to 82%) and 99% (95% CI 97% to 99%) for Type 2 tests, 78% (95% CI 69% to 84%) and 99% (95% CI 98% to 99%) for Type 3 tests, and 89% (95% CI 79% to 95%) and 98% (95% CI 97% to 99%) for Type 4 tests, respectively. Type 4 tests were more sensitive than both Type 2 (P = 0.01) and Type 3 tests (P = 0.03). Five studies compared Type 3 tests with PCR; in meta-analysis, the average sensitivity and specificity were 81% (95% CI 72% to 88%) and 99% (95% CI 97% to 99%) respectively. RDTs detecting P.vivax parasitaemia Eight studies compared pLDH tests to microscopy; the average sensitivity and specificity were 95% (95% CI 86% to 99%) and 99% (95% CI 99% to 100%), respectively. Authors' conclusions RDTs designed to detect P. vivax specifically, whether alone or as part of a mixed infection, appear to be more accurate than older tests designed to distinguish P. falciparum malaria from non-falciparum malaria. Compared to microscopy, these tests fail to detect around 5% ofP. vivax cases. This Cochrane Review, in combination with other published information about in vitro test performance and stability in the field, can assist policy-makers to choose between the available RDTs. PLAIN LANGUAGE SUMMARY Rapid tests for diagnosing malaria caused by Plasmodium vivax or other less common parasites This review summarises trials evaluating the accuracy of rapid diagnostic tests (RDTs) for diagnosing malaria due to Plasmodium vivax or other non-falciparum species. After searching for relevant studies up to December

  9. Rapid radioimmunological test for HCG in normal and disturbed early pregnancy

    International Nuclear Information System (INIS)

    Dericks-Tan, J.S.E.; Taubert, H.D.

    1979-01-01

    The clinical evaluation of a rapid radioimmunological test for HCG in serum showed that this method is as suitable as conventional radioimmunoassay or receptor methods in the diagnosis of normal and disturbed early pregnancy. Using a direct immunosorbent method total time requirements for the estimation could be reduced to half a working day. Sera of 314 women with normal pregnancies showed an exponential increase of HCG concentrations in serum during the first 8 weeks and thereafter steady levels for several weeks. As the anti-HCG serum used has only a slight cross reactivity with LH, false-positive results need hardly be expected in states if high LH levels in serum (menopause, polycystic ovaries, preovulatory LH peak). HCG concentrations in serum were clearly diminished in all pregnancies ending in abortion and in nearly all extrauterine pregnancies. Repeated estimations in early pregnancy enable a diagnosis of ectopic or disturbed intrauterine pregnancy to be made before symptoms of rupture, haemorrhage and similar complications occur. (orig.) [de

  10. Introducing rapid diagnostic tests for malaria into registered drug shops in Uganda

    DEFF Research Database (Denmark)

    Mbonye, Anthony K; Clarke, Sîan E; Lal, Sham

    2015-01-01

    BACKGROUND: Malaria is a major public health problem in Uganda and the current policy recommends introduction of rapid diagnostic tests for malaria (RDTs) to facilitate effective case management. However, provision of RDTs in drug shops potentially raises a new set of issues, such as adherence...... to RDTs results, management of severe illnesses, referral of patients, and relationship with caretakers. The main objective of the study was to examine the impact of introducing RDTs in registered drug shops in Uganda and document lessons and policy implications for future scale-up of malaria control...... in the private health sector. METHODS: A cluster-randomized trial introducing RDTs into registered drug shops was implemented in central Uganda from October 2010 to July 2012. An evaluation was undertaken to assess the impact and the processes involved with the introduction of RDTs into drug shops, the lessons...

  11. Factors associated with willingness to accept oral fluid HIV rapid testing among most-at-risk populations in China.

    Directory of Open Access Journals (Sweden)

    Huanmiao Xun

    Full Text Available The availability of oral fluid HIV rapid testing provides an approach that may have the potential to expand HIV testing in China, especially among most-a-risk populations. There are few investigations about the acceptability of oral fluid HIV testing among most-at-risk populations in China.A cross-sectional study with men who have sex with men (MSM, female sex workers (FSW and voluntary counseling and testing (VCT clients was conducted in three cities of Shandong province, China from 2011 to 2012. Data were collected by face-to-face questionnaire.About 71% of participants were willing to accept the oral fluid HIV rapid testing, and home HIV testing was independently associated with acceptability of the new testing method among MSM, FSW and VCT clients (AOR of 4.46, 3.19 and 5.74, respectively. Independent predictors of oral fluid HIV rapid testing acceptability among MSM were having ever taken an oral fluid HIV rapid test (AOR= 15.25, having ever taken an HIV test (AOR= 2.07, and education level (AOR= 1.74. Engagement in HIV-related risk behaviors (AOR= 1.68 was an independent predictor of acceptability for FSW. Having taken an HIV test (AOR= 2.85 was an independent predictor of acceptability for VCT clients. The primary concern about the oral fluid HIV testing was accuracy. The median price they would pay for the testing ranged from 4.8 to 8.1 U.S. dollars.High acceptability of oral fluid HIV rapid testing was shown among most-at-risk populations. Findings provide support for oral rapid HIV testing as another HIV prevention tool, and provide a backdrop for the implementation of HIV home testing in the near future. Appropriate pricing and increased public education through awareness campaigns that address concerns about the accuracy and safety of the oral fluid HIV rapid testing may help increase acceptability and use among most-at-risk populations in China.

  12. Diagnostic performance of a rapid in-clinic test for the detection of Canine Parvovirus under different storage conditions and vaccination status.

    Science.gov (United States)

    Kantere, Maria C; Athanasiou, Labrini V; Spyrou, Vassiliki; Kyriakis, Constantinos S; Kontos, Vassilios; Chatzopoulos, Dimitrios C; Tsokana, Constantina N; Billinis, Charalambos

    2015-04-01

    Canine parvovirus (CPV) is one of the most common causes of acute haemorrhagic enteritis in young dogs, while clinical diagnosis is often indecisive. The aim of our study was to evaluate the diagnostic accuracy of an in-clinic rapid test in the detection of CPV infection in dogs. To this end, we compared the Rapid Diagnostic Kit of Canine Parvovirus, Coronavirus and Rotavirus antigen (Quicking(®)) to PCR, which is considered as the most reliable diagnostic method. A total of 78 duplicated faecal samples were collected from diarrhoeic dogs. Vaccination history within a month prior to the onset of diarrhoea was reported for 12 of the sampled dogs. The rapid diagnostic test was performed in 23 of the faecal samples directly, while the rest were placed into a sterile cotton tipped swab suitable for collection and transportation of viruses (Sigma Σ-VCM(®)) and stored at -20 °C. The sensitivity of the Quicking rapid diagnostic test compared to PCR in the total number of samples, in samples from non-vaccinated dogs and in samples tested directly after collection were 22.22% (95% CI: 13.27-33.57%), 26.67% (95% CI: 16.08-39.66%) and 76.47% (95% CI: 50.10-93.04%) respectively, while the specificity of the test was 100% in any case. In conclusion, negative results do not exclude parvoenteritis from the differential diagnosis, especially in dogs with early vaccination history, but a positive result almost certainly indicates CPV infection. An improved sensitivity may be expected when the test is performed immediately. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    Science.gov (United States)

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Performance of a rapid self-test for detection of Trichomonas vaginalis in South Africa and Brazil

    NARCIS (Netherlands)

    Jones, Heidi E.; Lippman, Sheri A.; Caiaffa-Filho, Helio H.; Young, Taryn; van de Wijgert, Janneke H. H. M.

    2013-01-01

    Women participating in studies in Brazil (n = 695) and South Africa (n = 230) performed rapid point-of-care tests for Trichomonas vaginalis on self-collected vaginal swabs. Using PCR as the gold standard, rapid self-testing achieved high specificity (99.1%; 95% confidence interval [CI], 98.2 to

  15. Cone-beam computed tomography evaluation of dentoskeletal changes after asymmetric rapid maxillary expansion.

    Science.gov (United States)

    Baka, Zeliha Muge; Akin, Mehmet; Ucar, Faruk Izzet; Ileri, Zehra

    2015-01-01

    The aims of this study were to quantitatively evaluate the changes in arch widths and buccolingual inclinations of the posterior teeth after asymmetric rapid maxillary expansion (ARME) and to compare the measurements between the crossbite and the noncrossbite sides with cone-beam computed tomography (CBCT). From our clinic archives, we selected the CBCT records of 30 patients with unilateral skeletal crossbite (13 boys, 14.2 ± 1.3 years old; 17 girls, 13.8 ± 1.3 years old) who underwent ARME treatment. A modified acrylic bonded rapid maxillary expansion appliance including an occlusal locking mechanism was used in all patients. CBCT records had been taken before ARME treatment and after a 3-month retention period. Fourteen angular and 80 linear measurements were taken for the maxilla and the mandible. Frontally clipped CBCT images were used for the evaluation. Paired sample and independent sample t tests were used for statistical comparisons. Comparisons of the before-treatment and after-retention measurements showed that the arch widths and buccolingual inclinations of the posterior teeth increased significantly on the crossbite side of the maxilla and on the noncrossbite side of the mandible (P ARME treatment, the crossbite side of the maxilla and the noncrossbite side of the mandible were more affected than were the opposite sides. Copyright © 2015. Published by Elsevier Inc.

  16. Prospective study to evaluate the number and the location of biopsies in rapid urease test for diagnosis of Helicobacter Pylori

    Directory of Open Access Journals (Sweden)

    Antoine Abou Rached

    2017-11-01

    Full Text Available Helicobacter pylori (H. pylori can cause a wide variety of illnesses such as peptic ulcer disease, gastric adenocarcinoma and mucosa-associated lymphoid tissue (MALT lymphoma. The diagnosis and eradication of H. pylori are crucial. The diagnosis of H. pylori is usually based on the rapid urease test (RUT and gastric antral biopsy for histology. The aim of this study is to evaluate the numbers of needed biopsies and their location (antrum/fundus to obtain optimal result for the diagnosis of H. pylori. Three hundred fifty consecutive patients were recruited, 210 fulfill the inclusion criteria and had nine gastric biopsies for the detection of H. pylori infection: two antral for the first RUT (RUT1, one antral and one fundic for the second (RUT2, one antral for the third (RUT3 and two antral with two fundic for histology (HES, Giemsa, PAS. The reading of the 3 types of RUT was performed at 1 hour, 3 hours and 24 hours and biopsies were read by two experienced pathologists not informed about the result of RUT. Results of RUT were considered positive if H. pylori was found on histology of at least one biopsy. The RUT1 at 1h, 3h and 24h has a sensitivity of 72%, 82% and 89% and a specificity of 100%, 99% and 87% respectively. The positive predictive value (PPV was 100%, 99% and 85% respectively and the negative predictive value (NPV of 81%, 87% and 90%. The RUT2 at 1h, 3h and 24h, respectively, had a sensitivity of 86%, 87% and 91% and a specificity of 99%, 97% and 90%. The PPV was 99%, 96% and 88% and NPV of 89%, 90%, 94%. The RUT3 at 1h, 3h and 24h, respectively, had a sensitivity of 70%, 74% and 84% and a specificity of 99%, 99% and 94%. The PPV was 99%, 99% and 92% and NPV of 79%, 81% and 87%. The best sensitivity and specificity were obtained for RUT1 read at 3h, for RUT2 read 1h and 3h, and the RUT3 read at 24h.This study demonstrates that the best sensitivity and specificity of rapid test for urease is obtained when fundic plus antral biopsy

  17. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia.

    Science.gov (United States)

    Gaitán-Duarte, Hernando Guillermo; Newman, Lori; Laverty, Maura; Habib, Ndema Abu; González-Gordon, Lina María; Ángel-Müller, Edith; Abella, Catleya; Barros, Esther Cristina; Rincón, Carlos; Caicedo, Sidia; Gómez, Bertha; Pérez, Freddy

    2016-12-01

    To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC) centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A) or to dual HIV and syphilis rapid diagnostic tests (Arm B). The four main outcomes measured were: (1) acceptability of the test, (2) uptake in testing, (3) treatment on the same day (that is, timely treatment), and (4) treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69%) in Arm A and 16 of 20 patients (80%) in Arm B (relative risk (RR), 1.10; 95% confidence interval (CI): (1.00 -1.20). Treatment at any time was given to 24 of 29 patients (83%) in Arm A and to 20 of 20 (100%) in Arm B (RR, 1.11; 95% CI: 1.01-1.22). There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  18. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia

    Directory of Open Access Journals (Sweden)

    Hernando Guillermo Gaitán-Duarte

    Full Text Available ABSTRACT Objective To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. Methods A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A or to dual HIV and syphilis rapid diagnostic tests (Arm B. The four main outcomes measured were: (1 acceptability of the test, (2 uptake in testing, (3 treatment on the same day (that is, timely treatment, and (4 treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. Results A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69% in Arm A and 16 of 20 patients (80% in Arm B (relative risk (RR, 1.10; 95% confidence interval (CI: (1.00 −1.20. Treatment at any time was given to 24 of 29 patients (83% in Arm A and to 20 of 20 (100% in Arm B (RR, 1.11; 95% CI: 1.01−1.22. Conclusions There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  19. Evaluation of three oil spill laboratory dispersant effectiveness tests

    International Nuclear Information System (INIS)

    Sullivan, D.; Farlow, J.; Sahatjian, K.A.

    1993-01-01

    Chemical dispersants can be used to reduce the interfacial tension of floating oil slicks so that the oils disperse more rapidly into the water column and thus pose less of a threat to shorelines, birds, and marine mammals. The laboratory test currently specified in federal regulations to measure dispersant effectiveness is not especially easy or inexpensive, and generates a rather large quantity of oily waste water. This paper describes the results of an effort by the EPA to identify a more suitable laboratory dispersant effectiveness test. EPA evaluated three laboratory methods: the Revised Standard Dispersant Effectiveness Test currently used (and required by regulation) in the United States, the swirling flask test (developed by Environment Canada), and the IFP-dilution test (used in france and other European countries). Six test oils and three dispersants were evaluated; dispersants were applied to the oil at an average 1:10 ratio (dispersant to oil) for each of the three laboratory methods. Screening efforts were used to focus on the most appropriate oil/dispersant combination for detailed study. A screening criterion was established that required a combination that gave at least 20% effectiveness results. The selected combination turned out to be Prudhoe Bay crude oil and the dispersant Corexit 9527. This combination was also most likely to be encountered in US coastal waters. The EPA evaluation concluded that the three tests gave similar precision results, but that the swirling flask test was fastest, cheapest, simplest, and required least operator skill. Further, EPA is considering conducting the dispersant effectiveness test itself, rather than having data submitted by a dispersant manufacturer, and establishing an acceptability criterion (45% efficiency) which would have to be met before a dispersant could be placed on the Product Schedule of the National Contingency Plan (NCP)

  20. Rapid Isolation and Susceptibility Testing of Leptospira spp. Using a New Solid Medium, LVW Agar

    Science.gov (United States)

    Wuthiekanun, Vanaporn; Amornchai, Premjit; Paris, Daniel H.; Langla, Sayan; Thaipadunpanit, Janjira; Chierakul, Wirongrong; Smythe, Lee D.; White, Nicholas J.; Day, Nicholas P. J.; Peacock, Sharon J.

    2013-01-01

    Pathogenic Leptospira spp., the causative agents of leptospirosis, are slow-growing Gram-negative spirochetes. Isolation of Leptospira from clinical samples and testing of antimicrobial susceptibility are difficult and time-consuming. Here, we describe the development of a new solid medium that facilitates more-rapid growth of Leptospira spp. and the use of this medium to evaluate the Etest's performance in determining antimicrobial MICs to drugs in common use for leptospirosis. The medium was developed by evaluating the effects of numerous factors on the growth rate of Leptospira interrogans strain NR-20157. These included the type of base agar, the concentration of rabbit serum (RS), and the concentration and duration of CO2 incubation during the initial period of culture. The highest growth rate of NR-20157 was achieved using a Noble agar base supplemented with 10% RS (named LVW agar), with an initial incubation at 30°C in 5% CO2 for 2 days prior to continuous culture in air at 30°C. These conditions were used to develop the Etest for three species, L. interrogans (NR-20161), L. kirschnerii (NR-20327), and L. borgpetersenii (NR-20151). The MICs were read on day 7 for all samples. The Etest was then performed on 109 isolates of pathogenic Leptospira spp. The MIC90 values for penicillin G, doxycycline, cefotaxime, ceftriaxone, and chloramphenicol were 0.64 units/ml and 0.19, 0.047, 0.5, and 2 μg/ml, respectively. The use of LVW agar, which enables rapid growth, isolation of single colonies, and simple antimicrobial susceptibility testing for Leptospira spp., provides an opportunity for new areas of fundamental and applied research. PMID:23114772

  1. Rapid impact testing for quantitative assessment of large populations of bridges

    Science.gov (United States)

    Zhou, Yun; Prader, John; DeVitis, John; Deal, Adrienne; Zhang, Jian; Moon, Franklin; Aktan, A. Emin

    2011-04-01

    Although the widely acknowledged shortcomings of visual inspection have fueled significant advances in the areas of non-destructive evaluation and structural health monitoring (SHM) over the last several decades, the actual practice of bridge assessment has remained largely unchanged. The authors believe the lack of adoption, especially of SHM technologies, is related to the 'single structure' scenarios that drive most research. To overcome this, the authors have developed a concept for a rapid single-input, multiple-output (SIMO) impact testing device that will be capable of capturing modal parameters and estimating flexibility/deflection basins of common highway bridges during routine inspections. The device is composed of a trailer-mounted impact source (capable of delivering a 50 kip impact) and retractable sensor arms, and will be controlled by an automated data acquisition, processing and modal parameter estimation software. The research presented in this paper covers (a) the theoretical basis for SISO, SIMO and MIMO impact testing to estimate flexibility, (b) proof of concept numerical studies using a finite element model, and (c) a pilot implementation on an operating highway bridge. Results indicate that the proposed approach can estimate modal flexibility within a few percent of static flexibility; however, the estimated modal flexibility matrix is only reliable for the substructures associated with the various SIMO tests. To overcome this shortcoming, a modal 'stitching' approach for substructure integration to estimate the full Eigen vector matrix is developed, and preliminary results of these methods are also presented.

  2. Rapid testing may not improve uptake of HIV testing and same day results in a rural South African community: a cohort study of 12,000 women.

    Directory of Open Access Journals (Sweden)

    Ntombizodumo B Mkwanazi

    Full Text Available Rapid testing of pregnant women aims to increase uptake of HIV testing and results and thus optimize care. We report on the acceptability of HIV counselling and testing, and uptake of results, before and after the introduction of rapid testing in this area.HIV counsellors offered counselling and testing to women attending 8 antenatal clinics, prior to enrolment into a study examining infant feeding and postnatal HIV transmission. From August 2001 to April 2003, blood was sent for HIV ELISA testing in line with the Prevention of Mother-to-Child Transmission (PMTCT programme in the district. From May 2003 to September 2004 women were offered a rapid HIV test as part of the PMTCT programme, but also continued to have ELISA testing for study purposes. Of 12,323 women counselled, 5,879 attended clinic prior to May 2003, and 6,444 after May 2003 when rapid testing was introduced; of whom 4,324 (74.6% and 4,810 (74.6% agreed to have an HIV test respectively. Of the 4,810 women who had a rapid HIV test, only 166 (3.4% requested to receive their results on the same day as testing, the remainder opted to return for results at a later appointment. Women with secondary school education were less likely to agree to testing than those with no education (AOR 0.648, p35 years (AOR 0.756, p<0.01 compared to those <20 years.Contrary to other reports, few women who had rapid tests accepted their HIV results the same day. Finding strategies to increase the proportion of pregnant women knowing their HIV results is critical so that appropriate care can be given.

  3. HIV rapid diagnostic testing by lay providers in a key population-led health service programme in Thailand.

    Science.gov (United States)

    Wongkanya, Rapeeporn; Pankam, Tippawan; Wolf, Shauna; Pattanachaiwit, Supanit; Jantarapakde, Jureeporn; Pengnongyang, Supabhorn; Thapwong, Prasopsuk; Udomjirasirichot, Apichat; Churattanakraisri, Yutthana; Prawepray, Nanthika; Paksornsit, Apiluk; Sitthipau, Thidadaow; Petchaithong, Sarayut; Jitsakulchaidejt, Raruay; Nookhai, Somboon; Lertpiriyasuwat, Cheewanan; Ongwandee, Sumet; Phanuphak, Praphan; Phanuphak, Nittaya

    2018-01-01

    Introduction:  Rapid diagnostic testing (RDT) for HIV has a quick turn-around time, which increases the proportion of people testing who receive their result. HIV RDT in Thailand has traditionally been performed only by medical technologists (MTs), which is a barrier to its being scaled up. We evaluated the performance of HIV RDT conducted by trained lay providers who were members of, or worked closely with, a group of men who have sex with men (MSM) and with transgender women (TG) communities, and compared it to tests conducted by MTs. Methods:  Lay providers received a 3-day intensive training course on how to perform a finger-prick blood collection and an HIV RDT as part of the Key Population-led Health Services (KPLHS) programme among MSM and TG. All the samples were tested by lay providers using Alere Determine HIV 1/2. HIV-reactive samples were confirmed by DoubleCheckGold Ultra HIV 1&2 and SD Bioline HIV 1/2. All HIV-positive and 10% of HIV-negative samples were re-tested by MTs using Serodia HIV 1/2. Results:  Of 1680 finger-prick blood samples collected and tested using HIV RDT by lay providers in six drop-in centres in Bangkok, Chiang Mai, Chonburi and Songkhla, 252 (15%) were HIV-positive. MTs re-tested these HIV-positive samples and 143 randomly selected HIV-negative samples with 100% concordant test results. Conclusion:  Lay providers in Thailand can be trained and empowered to perform HIV RDT as they were found to achieve comparable results in sample testing with MTs. Based on the task-shifting concept, this rapid HIV testing performed by lay providers as part of the KPLHS programme has great potential to enhance HIV prevention and treatment programmes among key at-risk populations.

  4. Development of a novel and simple method to evaluate disintegration of rapidly disintegrating tablets.

    Science.gov (United States)

    Hoashi, Yohei; Tozuka, Yuichi; Takeuchi, Hirofumi

    2013-01-01

    The purpose of this study was to develop and test a novel and simple method for evaluating the disintegration time of rapidly disintegrating tablets (RDTs) in vitro, since the conventional disintegration test described in the pharmacopoeia produces poor results due to the difference of its environmental conditions from those of an actual oral cavity. Six RDTs prepared in our laboratory and 5 types of commercial RDTs were used as model formulations. Using our original apparatus, a good correlation was observed between in vivo and in vitro disintegration times by adjusting the height from which the solution was dropped to 8 cm and the weight of the load to 10 or 20 g. Properties of RDTs, such as the pattern of their disintegrating process, can be assessed by verifying the load. These findings confirmed that our proposed method for an in vitro disintegration test apparatus is an excellent one for estimating disintegration time and the disintegration profile of RDTs.

  5. [Introduction of rapid syphilis and HIV testing in prenatal care in Colombia: qualitative analysis].

    Science.gov (United States)

    Ochoa-Manjarrés, María Teresa; Gaitán-Duarte, Hernando Guillermo; Caicedo, Sidia; Gómez, Berta; Pérez, Freddy

    2016-12-01

    Interpret perceptions of Colombian health professionals concerning factors that obstruct and facilitate the introduction of rapid syphilis and HIV testing in prenatal care services. A qualitative study based on semi-structured interviews was carried out. A convenience sample was selected with 37 participants, who included health professionals involved in prenatal care services, programs for pregnant women, clinical laboratories, and directors of health care units or centers, as well as representatives from regional departments and the Ministry of Health. Colombia does not do widespread screening with rapid syphilis and HIV tests in prenatal care. The professionals interviewed stated they did not have prior experience in the use of rapid tests-except for laboratory staff-or in the course of action in response to a positive result. The insurance system hinders access to timely diagnosis and treatment. Health authorities perceive a need to review existing standards, strengthen the first level of care, and promote comprehensive prenatal care starting with contracts between insurers and health service institutional providers. Participants recommended staff training and integration between health-policymaking and academic entities for updating training programs. The market approach and the characteristics of the Colombian health system constitute the main barriers to implementation of rapid testing as a strategy for elimination of mother-to-child transmission of syphilis and HIV. Measures identified include making changes in contracts between insurers and health service institutional providers, adapting the timing and duration of prenatal care procedures, and training physicians and nurses involved in prenatal care.

  6. A method of rapidly evaluating image quality of NED optical system

    Science.gov (United States)

    Sun, Qi; Qiu, Chuankai; Yang, Huan

    2014-11-01

    In recent years, with the development of technology of micro-display, advanced optics and the software and hardware, near-to-eye display ( NED) optical system will have a wide range of potential applications in the fields of amusement and virtual reality. However, research on the evaluating image quality of this kind optical system is comparatively lagging behind. Although now there are some methods and equipment for evaluation, they can't be applied in commercial production because of their complex operation and inaccuracy. In this paper, an academic method is proposed and a Rapid Evaluation System (RES) is designed to evaluate the image of optical system rapidly and exactly. Firstly, a set of parameters that eyes are sensitive to and also express the quality of system should be extracted and quantized to be criterion, so the evaluation standards can be established. Then, some parameters can be detected by RES consisted of micro-display, CCD camera and computer and so on. By process of scaling, the measuring results of the RES are exact and creditable, relationship between object measurement, subjective evaluation and the RES will be established. After that, image quality of optical system can be evaluated just by detecting parameters of that. The RES is simple and the results of evaluation are exact and keeping with human vision. So the method can be used not only for optimizing design of optical system, but also for evaluation in commercial production.

  7. Evaluation of the β-CARBA™ test, a colorimetric test for the rapid detection of carbapenemase activity in Gram-negative bacilli.

    Science.gov (United States)

    Bernabeu, Sandrine; Dortet, Laurent; Naas, Thierry

    2017-06-01

    There is an urgent need for accurate and fast diagnostic tests to identify carbapenemase-producing bacteria. Here, we have evaluated a novel colorimetric test (the β-CARBA™ test; Bio-Rad) to detect carbapenemase-producing Gram-negative bacilli from cultured colonies. The performance of the β-CARBA™ test was compared with that of the Carba NP test (or the CarbAcineto NP test) and RAPIDEC ® CARBA NP (bioMérieux) using a collection of 290 isolates with characterized β-lactamase content. This collection included 199 carbapenemase producers (121 Enterobacteriaceae, 36 Pseudomonas and 42 Acinetobacter baumannii ) and 91 non-carbapenemase producers (55 Enterobacteriaceae, 20 Pseudomonas and 16 A. baumannii ). The β-CARBA™ test correctly detected 84.9% of the carbapenemase producers, including all KPC and IMP, 96.4% of VIM, 85.3% of NDM, 80.5% of OXA-48-like and 91.2% of A. baumannii -related OXA carbapenemases (OXA-23, OXA-40, OXA-58, OXA-143 and overexpressed OXA-51). All rare metallo-β-lactamases (SPM, AIM, GIM, DIM and SIM) were detected. Importantly, all non-KPC Ambler class A carbapenemases were not detected, including GES variants with carbapenemase activity ( n  = 6), IMI ( n  = 3), NMC-A ( n  = 1), SME ( n  = 2), FRI-1 ( n  = 1) and BIC-1 ( n  = 1). All non-carbapenemase producers gave a negative result except with OXA-163-, OXA-405- and one TEM-3-producing Citrobacter freundii . The overall sensitivity and specificity of the β-CARBA™ test were 84.9% and 95.6%, respectively. This test is easy to perform and to interpret by non-specialized staff members. Despite lack of specificity towards non-KPC Ambler class A and OXA-48-like carbapenemases, the β-CARBA™ test could complete the existing panel of tests available for the confirmation of carbapenemases in Gram-negatives. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For

  8. Miniaturized Antimicrobial Susceptibility Test by Combining Concentration Gradient Generation and Rapid Cell Culturing

    Directory of Open Access Journals (Sweden)

    Samuel C. Kim

    2015-10-01

    Full Text Available Effective treatment of bacterial infection relies on timely diagnosis and proper prescription of antibiotic drugs. The antimicrobial susceptibility test (AST is one of the most crucial experimental procedures, providing the baseline information for choosing effective antibiotic agents and their dosages. Conventional methods, however, require long incubation times or significant instrumentation costs to obtain test results. We propose a lab-on-a-chip approach to perform AST in a simple, economic, and rapid manner. Our assay platform miniaturizes the standard broth microdilution method on a microfluidic device (20 × 20 mm that generates an antibiotic concentration gradient and delivers antibiotic-containing culture media to eight 30-nL chambers for cell culture. When tested with 20 μL samples of a model bacterial strain (E. coli ATCC 25922 treated with ampicillin or streptomycin, our method allows for the determination of minimum inhibitory concentrations consistent with the microdilution test in three hours, which is almost a factor of ten more rapid than the standard method.

  9. Usefulness of a rapid faecal calprotectin test to predict relapse in Crohn's disease patients on maintenance treatment with adalimumab.

    Science.gov (United States)

    Ferreiro-Iglesias, Rocio; Barreiro-de Acosta, Manuel; Lorenzo-Gonzalez, Aurelio; Dominguez-Muñoz, Juan Enrique

    2016-01-01

    Predicting relapse in Crohn's disease (CD) patients by measuring non-invasive biomarkers could allow for early changes of treatment. Data are scarce regarding the utility of monitoring calprotectin to predict relapse. The aim of the study was to evaluate the predictive value of a rapid test of faecal calprotectin (FC) to predict for flares in CD patients on maintenance treatment with adalimumab (ADA). A prospective, observational cohort study was designed. Inclusion criteria were CD patients in clinical remission on a standard dose of ADA therapy. Fresh FC was measured using a rapid test. Thirty patients were included (median age 38 years, 56.7% female). After the 4 months follow-up, 70.0% patients remained in clinical remission and 30.0% had a relapse. FC concentration at inclusion was significantly higher in those patients who relapsed during the follow-up (625 μg/g) compared to those who stayed in remission (45 μg/g). The optimal cut-off for FC to predict relapse was 204 μg/g. The area under the receiver-operating characteristic curve was 0.968. Sensitivity, specificity, positive, and negative predictive value of FC to predict relapse were 100%, 85.7%, 74.1%, and 100%, respectively. In CD patients on ADA maintenance therapy, FC levels measured with a rapid test allow relapse over the following months to be predicted with high accuracy. Low FC levels exclude relapse within at least 4 months after testing, whereas high levels are associated with relapse in three out of every four patients.

  10. Introducing rapid tests for malaria into the retail sector

    DEFF Research Database (Denmark)

    Hutchinson, Eleanor; Hutchison, Coll; Lal, Sham

    2017-01-01

    The observation that many people in Africa seek care for febrile illness in the retail sector has led to a number of public health initiatives to try to improve the quality of care provided in these settings. The potential to support the introduction of rapid diagnostic tests for malaria (m......RDTs) into drug shops is coming under increased scrutiny. Those in favour argue that it enables the harmonisation of policy around testing and treatment for malaria and maintains a focus on market-based solutions to healthcare. Despite the enthusiasm among many global health actors for this policy option...... in drug shops during a trial in Mukono District, Uganda. This paper reports the unintended consequences of their introduction. It describes how the test engendered trust in the professional competence of DSVs; was misconstrued by clients and providers as enabling a more definitive diagnosis of disease...

  11. Evaluation of a rapid dipstick (Crystal VC for the diagnosis of cholera in Zanzibar and a comparison with previous studies.

    Directory of Open Access Journals (Sweden)

    Benedikt Ley

    Full Text Available The gold standard for the diagnosis of cholera is stool culture, but this requires laboratory facilities and takes at least 24 hours. A rapid diagnostic test (RDT that can be used by minimally trained staff at treatment centers could potentially improve the reporting and management of cholera outbreaks.We evaluated the Crystal VC™ RDT under field conditions in Zanzibar in 2009. Patients presenting to treatment centers with watery diarrhea provided a stool sample for rapid diagnostic testing. Results were compared to stool culture performed in a reference laboratory. We assessed the overall performance of the RDT and evaluated whether previous intake of antibiotics, intravenous fluids, location of testing, and skill level of the technician affected the RDT results.We included stool samples from 624 patients. Compared to culture, the overall sensitivity of the RDT was 93.1% (95%CI: 88.7 to 96.2%, specificity was 49.2% (95%CI: 44.3 to 54.1%, the positive predictive value was 47.0% (95%CI: 42.1 to 52.0% and the negative predictive value was 93.6% (95%CI: 89.6 to 96.5%. The overall false positivity rate was 50.8% (213/419; fieldworkers frequently misread very faint test lines as positive.The observed sensitivity of the Crystal VC RDT evaluated was similar compared to earlier versions, while specificity was poorer. The current version of the RDT could potentially be used as a screening tool in the field. Because of the high proportion of false positive results when field workers test stool specimens, positive results will need to be confirmed with stool culture.

  12. Mobile Image Ratiometry: A New Method for Instantaneous Analysis of Rapid Test Strips

    OpenAIRE

    Donald C. Cooper; Bryan Callahan; Phil Callahan; Lee Burnett

    2012-01-01

    Here we describe Mobile Image Ratiometry (MIR), a new method for the automated quantification of standardized rapid immunoassay strips using consumer-based mobile smartphone and tablet cameras. To demonstrate MIR we developed a standardized method using rapid immunotest strips directed against cocaine (COC) and its major metabolite, benzoylecgonine (BE). We performed image analysis of three brands of commercially available dye-conjugated anti-COC/BE antibody test strips in response to three d...

  13. Accuracy of a rapid 10-minute carbon-14 urea breath test for the diagnosis of Helicobacter pylori-associated peptic ulcer disease

    Energy Technology Data Exchange (ETDEWEB)

    Chiahung, Kao [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Shyhjen, Wang [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Chungyuan, Hsu [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Wanyu, Lin [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Chihkua, Huang [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Gastroenterology; Granhum, Chen [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Gastroenterology

    1993-08-01

    Urease in the human gastric mucosa is a marker for infection with Helicobacter pylori (HP), an organism which is associated with peptic ulcer disease. To detect gastric urease, we examined 184 patients (144 males, 40 females; mean age: 49.8[+-]15.6 years) with suspected peptic ulcer disease. Fasting patients were given orally 5 [mu]Ci of carbon-14 labelled urea. For each patient only one breath sample was collected in hyamine at 10 min. The amount of [sup 14]C collected at 10 min was expressed as follows: (DPM/mmol CO[sub 2] collected)/(DPM administered)x100xbody weight (kg). The presence of HP colonization was determined by examination of multiple endoscopic prepyloric antral biopsy specimens subjected to culture or a rapid urease test. For the purpose of this study, HP-positive patients were defined as those with characteristic bacteria as indicated by a positive result of either the culture or the rapid urease test; HP-negative patients were defined as those with negative findings on both the culture and the rapid urease test. Of the 184 cases, 99 (53.8%) were positive for HP infection, and 85 (46.2%), negative. The sensitivity and specificity of the rapid 10 min [sup 14]C-urea breath test for the diagnosis of HP-associated peptic ulcer disease were evaluated by a receiver operating characteristic (ROC) curve with a variable cut-off value from 1.5 to 4.5. When a cut-off value of 1.5 was selected, the sensitivity was 100% and the specificity, 83.5%; when a cut-off value of 4.5 was selected, the sensitivity was 54.5% and the specificity, 97.6%. (orig.)

  14. Accuracy of a rapid 10-minute carbon-14 urea breath test for the diagnosis of Helicobacter pylori-associated peptic ulcer disease

    International Nuclear Information System (INIS)

    Kao Chiahung; Wang Shyhjen; Hsu Chungyuan; Lin Wanyu; Huang Chihkua; Chen Granhum

    1993-01-01

    Urease in the human gastric mucosa is a marker for infection with Helicobacter pylori (HP), an organism which is associated with peptic ulcer disease. To detect gastric urease, we examined 184 patients (144 males, 40 females; mean age: 49.8±15.6 years) with suspected peptic ulcer disease. Fasting patients were given orally 5 μCi of carbon-14 labelled urea. For each patient only one breath sample was collected in hyamine at 10 min. The amount of 14 C collected at 10 min was expressed as follows: [(DPM/mmol CO 2 collected)/(DPM administered)]x100xbody weight (kg). The presence of HP colonization was determined by examination of multiple endoscopic prepyloric antral biopsy specimens subjected to culture or a rapid urease test. For the purpose of this study, HP-positive patients were defined as those with characteristic bacteria as indicated by a positive result of either the culture or the rapid urease test; HP-negative patients were defined as those with negative findings on both the culture and the rapid urease test. Of the 184 cases, 99 (53.8%) were positive for HP infection, and 85 (46.2%), negative. The sensitivity and specificity of the rapid 10 min 14 C-urea breath test for the diagnosis of HP-associated peptic ulcer disease were evaluated by a receiver operating characteristic (ROC) curve with a variable cut-off value from 1.5 to 4.5. When a cut-off value of 1.5 was selected, the sensitivity was 100% and the specificity, 83.5%; when a cut-off value of 4.5 was selected, the sensitivity was 54.5% and the specificity, 97.6%. (orig.)

  15. Clinical usefulness of a biomarker-based diagnostic test for acute stroke: the Biomarker Rapid Assessment in Ischemic Injury (BRAIN) study.

    Science.gov (United States)

    Laskowitz, Daniel T; Kasner, Scott E; Saver, Jeffrey; Remmel, Kerri S; Jauch, Edward C

    2009-01-01

    One of the significant limitations in the evaluation and management of patients with suspected acute cerebral ischemia is the absence of a widely available, rapid, and sensitive diagnostic test. The objective of the current study was to assess whether a test using a panel of biomarkers might provide useful diagnostic information in the early evaluation of stroke by differentiating patients with cerebral ischemia from other causes of acute neurological deficit. A total of 1146 patients presenting with neurological symptoms consistent with possible stroke were prospectively enrolled at 17 different sites. Timed blood samples were assayed for matrix metalloproteinase 9, brain natriuretic factor, d-dimer, and protein S100beta. A separate cohort of 343 patients was independently enrolled to validate the multiple biomarker model approach. A diagnostic tool incorporating the values of matrix metalloproteinase 9, brain natriuretic factor, d-dimer, and S-100beta into a composite score was sensitive for acute cerebral ischemia. The multivariate model demonstrated modest discriminative capabilities with an area under the receiver operating characteristic curve of 0.76 for hemorrhagic stroke and 0.69 for all stroke (likelihood test P<0.001). When the threshold for the logistic model was set at the first quartile, this resulted in a sensitivity of 86% for detecting all stroke and a sensitivity of 94% for detecting hemorrhagic stroke. Moreover, results were reproducible in a separate cohort tested on a point-of-care platform. These results suggest that a biomarker panel may add valuable and time-sensitive diagnostic information in the early evaluation of stroke. Such an approach is feasible on a point-of-care platform. The rapid identification of patients with suspected stroke would expand the availability of time-limited treatment strategies. Although the diagnostic accuracy of the current panel is clearly imperfect, this study demonstrates the feasibility of incorporating a

  16. Rapid prototyping of centrifugal microfluidic modules for point of care blood testing

    CSIR Research Space (South Africa)

    Madzivhandila, Phophi

    2016-11-01

    Full Text Available We present modular centrifugal microfluidic devices that enable a series of blood tests to be performed towards a full blood count. The modular approach allows for rapid prototyping of device components in a generic format to complete different...

  17. Evaluation of GenoType® MTBDRplus assay for rapid detection of drug susceptibility testing of multi-drug resistance tuberculosis in Northern India

    Directory of Open Access Journals (Sweden)

    Anand Kumar Maurya

    2013-01-01

    Full Text Available Background: The problem of multi-drug resistance tuberculosis (MDR-TB is growing in several hotspots throughout the world. Rapid and accurate diagnosis of MDR-TB is crucial to facilitate early treatment and to reduce its spread in the community. The aim of the present study was to evaluate the new, novel GenoType® MTBDRplus assay for rapid detection of drug susceptibility testing (DST of MDR-TB cases in Northern India. Materials and Methods: A total of 550 specimens were collected from highly suspected drug resistant from pulmonary and extra-pulmonary TB cases. All the specimens were processed by Ziehl- Neelsen staining, culture, differentiation by the GenoType® CM assay, first line DST using BacT/ALERT 3D system and GenoType® MTBDRplus assay. The concordance of the GenoType® MTBDRplus assay was calculated in comparison with conventional DST results. Results: Overall the sensitivity for detection of rifampicin, isoniazid and MDR-TB resistance by GenoType® MTBDRplus assay was 98.0%, 98.4% and 98.2% respectively. Out of 55 MDR-TB strains, 45 (81.8%, 52 (94.5% and 17 (30.9% strains showed mutation in rpoB, katG and inhA genes respectively (P < 0.05. The most prominent mutations in rpoB, katG and inhA genes were; 37 (67.3% in S531L, 52 (94.5% in S315T1 and 11 (20% in C15T regions respectively (P < 0.05. Conclusions: Our study demonstrated a high concordance between the GenoType® MTBDRplus assay resistance patterns and those were observed by conventional DST with good sensitivity, specificity with short turnaround times and to control new cases of MDR-TB in countries with a high prevalence of MDR-TB.

  18. A Lateral Flow Rapid Test for Human Toxocariasis Developed Using Three Toxocara canis Recombinant Antigens.

    Science.gov (United States)

    Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah

    2018-01-01

    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.

  19. Operational feasibility of using whole blood in the rapid HIV testing algorithm of a resource-limited settings like Bangladesh.

    Science.gov (United States)

    Munshi, Saif U; Oyewale, Tajudeen O; Begum, Shahnaz; Uddin, Ziya; Tabassum, Shahina

    2016-03-01

    Serum-based rapid HIV testing algorithm in Bangladesh constitutes operational challenge to scaleup HIV testing and counselling (HTC) in the country. This study explored the operational feasibility of using whole blood as alternative to serum for rapid HIV testing in Bangladesh. Whole blood specimens were collected from two study groups. The groups included HIV-positive patients (n = 200) and HIV-negative individuals (n = 200) presenting at the reference laboratory in Dhaka, Bangladesh. The specimens were subjected to rapid HIV tests using the national algorithm with A1 = Alere Determine (United States), A2 = Uni-Gold (Ireland), and A3 = First Response (India). The sensitivity and specificity of the test results, and the operational cost were compared with current serum-based testing. The sensitivities [95% of confidence interval (CI)] for A1, A2, and A3 tests using whole blood were 100% (CI: 99.1-100%), 100% (CI: 99.1-100%), and 97% (CI: 96.4-98.2%), respectively, and specificities of all test kits were 100% (CI: 99.1-100%). Significant (P < 0.05) reduction in the cost of establishing HTC centre and consumables by 94 and 61%, respectively, were observed. The cost of administration and external quality assurance reduced by 39 and 43%, respectively. Overall, there was a 36% cost reduction in total operational cost of rapid HIV testing with blood when compared with serum. Considering the similar sensitivity and specificity of the two specimens, and significant cost reduction, rapid HIV testing with whole blood is feasible. A review of the national HIV rapid testing algorithm with whole blood will contribute toward improving HTC coverage in Bangladesh.

  20. Rapid Evaluation of Platelet Function With T2 Magnetic Resonance

    Science.gov (United States)

    Cuker, Adam; Husseinzadeh, Holleh; Lebedeva, Tatiana; Marturano, Joseph E.; Massefski, Walter; Lowery, Thomas J.; Lambert, Michele P.; Abrams, Charles S.; Weisel, John W.

    2016-01-01

    Objectives: The clinical diagnosis of qualitative platelet disorders (QPDs) based on light transmission aggregometry (LTA) requires significant blood volume, time, and expertise, all of which can be barriers to utilization in some populations and settings. Our objective was to develop a more rapid assay of platelet function by measuring platelet-mediated clot contraction in small volumes (35 µL) of whole blood using T2 magnetic resonance (T2MR). Methods: We established normal ranges for platelet-mediated clot contraction using T2MR, used these ranges to study patients with known platelet dysfunction, and then evaluated agreement between T2MR and LTA with arachidonic acid, adenosine diphosphate, epinephrine, and thrombin receptor activator peptide. Results: Blood from 21 healthy donors was studied. T2MR showed 100% agreement with LTA with each of the four agonists and their cognate inhibitors tested. T2MR successfully detected abnormalities in each of seven patients with known QPDs, with the exception of one patient with a novel mutation leading to Hermansky-Pudlak syndrome. T2MR appeared to detect platelet function at similar or lower platelet counts than LTA. Conclusions: T2MR may provide a clinically useful approach to diagnose QPDs using small volumes of whole blood, while also providing new insight into platelet biology not evident using plasma-based platelet aggregation tests. PMID:28028118

  1. A rapid, sensitive and reliable diagnostic test for scrub typhus in China

    Directory of Open Access Journals (Sweden)

    Zhang Lijuan

    2011-01-01

    Full Text Available Purpose: To evaluate the performances for detection of IgM and IgG antibodies to Orientia. tsutsugamushi (Ot using a gold conjugate-based rapid diagnostic test (RDT. Materials and Methods: The RDT employing mixture recombinant 56-kDa proteins of O. tsutsugamushi and the mIFA assay was performed on 33 patients from Fujian and Yunnan province respectively and 94 positive sera (36 from Hainan province and 58 from Jiangsu province from convalescent stages of the patients with scrub typhus respectively and 82 negative sera from healthy farmers from Anhui province and Beijing City respectively in 2009. A comparison of the RDT and mIFA assay was performed by using the c2 test and the P level of ≤0.05 was considered to be significant. Results: Among these 94 positive sera from convalescent stages of the illness and 82 sera from control farmers, the specificity of RDT was 100% for both IgM and IgG tests. In 33 cases with scrub typhus, 5 cases were positively detected earlier by RDT than by mIFA for the IgM test, and 2 cases were positive for the IgG test. The sensitivities of RDT were 93.9% and 90.9% for IgM and IgG, respectively. Considering IgM and IgG together, the sensitivity was 100%. The geometric mean titre (GMT of IFA and the RDT assay in diluted sera from confirmed cases were 1:37 versus 1:113 respectively (P<0.001 for IgM test and 1:99 versus 1:279 respectively (P<0.016 for IgG. Conclusions: The RDT was more sensitive than the traditional IFA for the early diagnosis of scrub typhus and was particularly suitable for use in rural areas.

  2. Rapid in vivo screening method for the evaluation of new anti ...

    African Journals Online (AJOL)

    Rapid in vivo screening method for the evaluation of new anti helicobacter ... Six to eight week-old mice pre-treated (7 days) with Amoxicillin/Metronidazole (25 ... These findings were used as a mouse model of Helicobacter pylori infection to ...

  3. Applying core principles to the design and evaluation of the 'Take Charge. Take the Test' campaign: what worked and lessons learned.

    Science.gov (United States)

    Fraze, J L; Uhrig, J D; Davis, K C; Taylor, M K; Lee, N R; Spoeth, S; Robinson, A; Smith, K; Johnston, J; McElroy, L

    2009-09-01

    To describe the application of seven core principles to the design and evaluation of a human immunodeficiency virus (HIV) testing social marketing campaign as a case study example. The Centers for Disease Control and Prevention (CDC) used a structured social marketing approach, informed by the Ecological Model, the Theory of Planned Behaviour and the Health Belief Model, to develop and evaluate a two-city campaign with print, radio and outdoor advertising; HIV telephone hotlines; an HIV website; community partnerships; and events to promote information seeking and HIV testing. The CDC applied seven core principles to design and evaluate the campaign, including formative research, the use of behavioural theories, audience segmentation, message design and pretesting, channel selection, process evaluation and outcome evaluation. Over 200 partners in both cities contributed significantly to campaign efforts. Key informant interviews indicated that, due to increased coordination, city infrastructures for HIV testing improved. More than 9600 individuals attended campaign events in both cities, with 1492 rapid HIV tests administered and 14 newly-identified HIV individuals. Overall, event attendees responded positively to campaign materials and events, and free HIV testing opportunities. The campaign significantly increased information-seeking behaviours in the form of hotline calls and web searches. Audience reaction and receptivity to the final campaign materials was very high. Exposure to campaign messages was associated with increases in key knowledge items, intentions to get tested, and peer-to-peer communication. The seven core principles, including formative research, behavioural theories and extensive partnerships, acted synergistically to help a campaign reach its target audience with compelling, relevant messages and motivate them to seek information and get an HIV test. Rapid testing removes many barriers by providing a testing process that can be accessed and

  4. Evaluation of rapid immuno chromatographic assay kit using monoclonal mpt64 antibodies for identification of mycobacterium tuberculosis complex

    International Nuclear Information System (INIS)

    Satti, L.; Ikram, A.; Malik, N.

    2010-01-01

    To evaluate the performance of rapid immuno chromatographic kit MPT64 Ag for the identification of Mycobacterium tuberculosis complex from various Mycobacterium tuberculosis culture positive specimens. Department of Microbiology, Armed Forces Institute of Pathology Rawalpindi, from August 2008 through March 2009. Eighty four Mycobacterium tuberculosis positive cultures on I BACTEC 460 and MGIT 960, one ATCC 25177 MTB strain, three institutional control MTB strains, two institutional control MOTT strains and 20 different bacterial isolates were tested. Tests were performed according to the instructional manual. Out of total 84 tested samples, MPT64 showed positive result in 80 cultures. Only four positive cultures did not display any band on MPT64 kit. These four strains were reconfirmed as Mycobacterium tuberculosis by PCR method. MOTT control strains and all the 20 bacterial isolates were negative for band. The sensitivity and specificity of ICT assay in our study was 95.2% and 100% respectively. Rapid MPT64 Kit is a good diagnostic tool to differentiate between Mycobacterium tuberculosis complex and MOTT with 100% specificity. The technique is simple and can provide prompt information to the clinicians to initiate early and appropriate antituberculosis therapy. (author)

  5. Will gay and bisexually active men at high risk of infection use over-the-counter rapid HIV tests to screen sexual partners?

    Science.gov (United States)

    Carballo-Diéguez, Alex; Frasca, Timothy; Dolezal, Curtis; Balan, Ivan

    2012-01-01

    The Food and Drug Administration may license OraQuick™, a rapid HIV test, for over-the-counter (OTC) sale. This study investigated whether HIV-uninfected, non-monogamous, gay and bisexual men who never or rarely use condoms would use the test with partners as a harm-reduction approach. Sixty participants responded to two computer-assisted self-interviews, underwent an in-depth interview, and chose whether to test themselves with OraQuick. Over 80% of the men said they would use the kit to test sexual partners or themselves if it became available OTC. Most participants understood that antibody tests have a window period in which the virus is undetectable, yet saw advantages to using the test to screen partners; 74% tested themselves in our offices. Participants offered several possible strategies to introduce the home-test idea to partners, frequently endorsed mutual testing, and highlighted that home testing could stimulate greater honesty in serostatus disclosure. Participants drew distinctions between testing regular versus occasional partners. Non-monogamous men who have sex with men, who never or rarely use condoms, may nevertheless seek to avoid HIV. Technologies that do not interfere with sexual pleasure are likely to be used when available. Studies are needed to evaluate the advantages and disadvantages of using OTC rapid HIV tests as one additional harm-reduction tool.

  6. Rapid Point-of-Care Diagnostic Test for Syphilis in High-Risk Populations, Manaus, Brazil

    OpenAIRE

    Sabid?, Meritxell; Benzaken, Adele S.; de Andrade Rodrigues, ?nio Jos?; Mayaud, Philippe

    2009-01-01

    : We assessed the acceptability and operational suitability of a rapid point-of-care syphilis test and identified barriers to testing among high-risk groups and healthcare professionals in a sexually transmitted infections clinic in Manaus, Brazil. Use of this test could considerably alleviate the impact of syphilis in hard-to-reach populations in the Amazon region of Brazil.

  7. Antimicrobial susceptibility testing of rapidly growing mycobacteria by microdilution - Experience of a tertiary care centre

    Directory of Open Access Journals (Sweden)

    Set R

    2010-01-01

    Full Text Available Purpose: The objective of the study was to perform antimicrobial susceptibility testing of rapidly growing mycobacteria (RGM isolated from various clinically suspected cases of extrapulmonary tuberculosis, from January 2007 to April 2008, at a tertiary care centre in Mumbai. Materials and Methods: The specimens were processed for microscopy and culture using the standard procedures. Minimum inhibitory concentrations (MIC were determined by broth microdilution, using Sensititre CA MHBT. Susceptibility testing was also carried out on Mueller Hinton agar by the Kirby Bauer disc diffusion method. Results: Of the 1062 specimens received for mycobacterial cultures, 104 (9.79% grew mycobacteria. Of the mycobacterial isolates, six (5.76% were rapid growers. M. abscessus and M. chelonae appeared to be resistant organisms, with M. chelonae showing intermediate resistance to amikacin and minocycline. However, all the six isolates showed sensitivity to vancomycin and gentamicin by the disc diffusion test. Also all three isolates of M. abscessus were sensitive to piperacillin and erythromycin. Further studies are required to test their sensitivity to these four antimicrobials by using the microbroth dilution test, before they can be prescribed to patients. Conclusions: We wish to emphasize that reporting of rapidly growing mycobacteria from clinical settings, along with their sensitivity patterns, is an absolute need of the hour.

  8. Rapid earthquake magnitude determination for Vrancea early warning system

    International Nuclear Information System (INIS)

    Marmureanu, Alexandru

    2009-01-01

    Due to the huge amount of recorded data, an automatic procedure was developed and used to test different methods to rapidly evaluate earthquake magnitude from the first seconds of the P wave. In order to test all the algorithms involved in detection and rapid earthquake magnitude estimation, several tests were performed, in order to avoid false alarms. A special detection algorithm was developed, that is based on the classical STA/LTA algorithm and tuned for early warning purpose. A method to rapidly estimate magnitude in 4 seconds from detection of P wave in the epicenter is proposed. The method was tested on al recorded data, and the magnitude error determination is acceptable taking into account that it is computed from only 3 stations in a very short time interval. (author)

  9. Evaluation du test rapide oral aware™ omt HIV 1/2 pour le ...

    African Journals Online (AJOL)

    Chaque participant a fourni un échantillon de fluide oral pour la réalisation du test Aware™ OMT HIV-1/2 et du sang testé suivant l'algorithme séquentiel de tests ELISAs Murex® HIV-1.2.0 (Laboratoires Abbott, Japon) et Test ELISA peptidique maison du CeDReS. Résultats : la sensibilité, la spécificité, la Valeur Prédictive ...

  10. A high frequency test bench for rapid single-flux-quantum circuits

    International Nuclear Information System (INIS)

    Engseth, H; Intiso, S; Rafique, M R; Tolkacheva, E; Kidiyarova-Shevchenko, A

    2006-01-01

    We have designed and experimentally verified a test bench for high frequency testing of rapid single-flux-quantum (RSFQ) circuits. This test bench uses an external tunable clock signal that is stable in amplitude, phase and frequency. The high frequency external clock reads out the clock pattern stored in a long shift register. The clock pattern is consequently shifted out at high speed and split to feed both the circuit under test and an additional shift register in the test bench for later verification at low speed. This method can be employed for reliable high speed verification of RSFQ circuit operation, with use of only low speed read-out electronics. The test bench consists of 158 Josephson junctions and the occupied area is 3300 x 660 μm 2 . It was experimentally verified up to 33 GHz with ± 21.7% margins on the global bias supply current

  11. Evaluation of mechanical properties for spherical magnetic regenerator materials fabricated by rapid solidification process

    International Nuclear Information System (INIS)

    Okamura, M.; Sori, N.; Saito, A.

    1997-01-01

    Various magnetic regenerator materials, such as Er 3 Ni, Er 3 Co and ErNi, are fabricated in the form of a spherical particle by a rapid solidification process. 4 K level refrigeration has been obtained by a GM refrigerator using these materials. However, the magnetic regenerator materials are considered brittle, as they are intermetallic compounds. It is important to evaluate the mechanical properties of these materials to confirm reliability as a regenerator material. In this paper, experimental results of compression and vibration tests for magnetic regenerator materials are described. The technical point of this study is to use spherical particles as test samples. The compressive stress of 20 MPa was applied to these spherical particles and no fractured spheres were observed. Similarly, no fractured spheres were found after the vibration test, in which the maximum acceleration was 30 X 9.8 m/s 2 and the number of vibration times was 1 X 10 6 , insofar as there was no room to stir spherical particles in a regenerator. In practice, the reliability of magnetic regenerator materials has been confirmed by a long-run test of 7,000 h in a usual GM refrigerator

  12. A rapid phenol toxicity test based on photosynthesis and movement of the freshwater flagellate, Euglena agilis Carter

    International Nuclear Information System (INIS)

    Kottuparambil, Sreejith; Kim, Youn-Jung; Choi, Hoon; Kim, Mi-Sung; Park, Areum; Park, Jihae; Shin, Woongghi; Han, Taejun

    2014-01-01

    Highlights: • Rapid phenol toxicity tests (1 h) were developed based on Chl a fluorescence and the movement parameters of Euglena agilis. • Phenol significantly reduced F v /F m of PS II and rETRmax with EC50 values of 8.94 and 4.67 mM, respectively. • Among the movement parameters tested, velocity was the most sensitive biomarker with an EC50 of 3.17 mM. • The EC50 values for F v /F m , motility, and velocity appear to overlap the environmental permissible levels of phenol. - Abstract: Phenol, a monosubstituted aromatic hydrocarbon with various commercial uses, is a major organic constituent in industrial wastewaters. The ecotoxic action of phenol for aquatic environment is well known. In this study, rapid phenol toxicity tests (1 h) were developed based on chlorophyll a (Chl a) fluorescence and the movement parameters of the freshwater flagellate, Euglena agilis Carter. Phenol significantly reduced the maximum quantum yield (F v /F m ) of photosystem II (PS II) and the maximum photosynthetic electron transport rate (rETR max ) with median effective concentration (EC 50 ) values of 8.94 and 4.67 mM, respectively. Phenol reduced the motility and triggered change in the swimming velocity of the test organism. Among the parameters tested, velocity was the most sensitive biomarker with an EC 50 of 3.17 mM. The EC 50 values for F v /F m , motility, and velocity appear to overlap the permitted levels of phenol. In conclusion, the photosynthesis and movement of E. agilis can be fast and sensitive risk assessment parameters for the evaluation of phenol toxicity in municipal and industrial effluents

  13. Evaluation of an Immunochromatographic Test for Rapid and Reliable Serodiagnosis of Human Tularemia and Detection of Francisella tularensis-Specific Antibodies in Sera from Different Mammalian Species ▿

    Science.gov (United States)

    Splettstoesser, W.; Guglielmo-Viret, V.; Seibold, E.; Thullier, P.

    2010-01-01

    Tularemia is a highly contagious infectious zoonosis caused by the bacterial agent Francisella tularensis. Serology is still considered to be a cornerstone in tularemia diagnosis due to the low sensitivity of bacterial culture and the lack of standardization in PCR methodology for the direct identification of the pathogen. We developed a novel immunochromatographic test (ICT) to efficiently detect F. tularensis-specific antibodies in sera from humans and other mammalian species (nonhuman primate, pig, and rabbit). This new tool requires none or minimal laboratory equipment, and the results are obtained within 15 min. When compared to the method of microagglutination, which was shown to be more specific than the enzyme-linked immunosorbent assay, the ICT had a sensitivity of 98.3% (58 positive sera were tested) and a specificity of 96.5% (58 negative sera were tested) on human sera. On animal sera, the overall sensitivity was 100% (22 positive sera were tested) and specificity was also 100% (70 negative sera were tested). This rapid test preferentially detects IgG antibodies that may occur early in the course of human tularemia, but further evaluation with human sera is important to prove that the ICT can be a valuable field test to support a presumptive diagnosis of tularemia. The ICT can also be a useful tool to monitor successful vaccination with subunit vaccines or live vaccine strains containing lipopolysaccharide (e.g., LVS) and to detect seropositive individuals or animals in outbreak situations or in the context of epidemiologic surveillance programs in areas of endemicity as recently recommended by the World Health Organization. PMID:20220165

  14. Selection of a Battery of Rapid Toxicity Sensors for Drinking Water Evaluation

    National Research Council Canada - National Science Library

    van der Schalie, William H; James, Ryan R; Gargan, II., Thomas P

    2006-01-01

    .... Ten toxicity sensors utilizing enzymes, bacteria, or vertebrate cells were tested to determine the minimum number of sensors that could rapidly identify toxicity in water samples containing one of 12...

  15. Monitoring people at risk of drinking by a rapid urinary ethyl glucuronide test

    Directory of Open Access Journals (Sweden)

    Fucci Nadia

    2017-12-01

    Full Text Available Alcohol and illicit drug abuse are major public health problems worldwide. Since alcohol is the predominant substance of choice in polydrug abusers, monitoring its use, along with urinary drug screening in patients in rehabilitation programs, appeared to be crucial in identifying patients at risk of alcohol disorders leading to impaired quality of life. Ethyl β-D-6-glucuronide, a non-oxidative, non-volatile, stable and minor direct ethanol metabolite, has a 6h to 4 day window of detection in urine after the last alcohol intake. Each of the 119 subjects (85 males, 34 females registered with the Public Health Service for Drug Dependence Treatment provided a urine sample for ethylglucoronide (EtG determination in an immunochemical test with a 500 ng/ml cutoff. All results were evaluated with confirmation criteria of a fully validated gas chromatography/mass spectrometry assay. The diagnostic performance of the EtG immunochemical test was assessed using Receiver Operating Characteristic Curve analysis. The immunochemical test specificity was 100% for EtG urinary values above 500 ng/ml. No false positive results were found. With levels below 500 ng/ml, 12% of the samples were classified as negative. The average consumption of the incorrectly classified subjects was 171 ng/ml, with a misclassification error of 6.5% to 18.5%. High agreement between EtG as determined in an immunochemical test and gas chromatography/mass spectrometry, suggests that the rapid EtG test is a reliable, cost-effective alcohol monitoring assay for patient management in many non-forensic settings, such as drug rehabilitation programs.

  16. Is Serial Testing Required to Diagnose Imported Malaria in the Era of Rapid Diagnostic Tests?

    Science.gov (United States)

    Pasricha, Janet M.; Juneja, Surender; Manitta, Joseph; Whitehead, Susan; Maxwell, Ellen; Goh, Wai-Keong; Pasricha, Sant-Rayn; Eisen, Damon P.

    2013-01-01

    Exclusion of malaria traditionally requires three negative serial thick and thin blood films. However, many clinical laboratories now routinely perform rapid diagnostic tests (RDTs) in addition to blood films when malaria is suspected. We sought to determine whether serial testing is necessary in this setting. We examined 388 cases of malaria diagnosed during 1999–2010 at three laboratories in Melbourne, Australia. For each case, we ascertained whether the diagnosis was made on initial or follow-up testing. Nine cases (3.5%) were diagnosed after a negative initial blood film and RDT: 7 Plasmodium vivax, 1 P. ovale, and 1 P. falciparum. Of four case-patients with P. vivax in which clinical data were available, all had recent exposure to antimalarial medication. Our data suggest that among patients who have not received recent anti-malarial therapy, and when RDTs are performed and blood films are prepared, most malaria diagnoses are made by using the first set of tests. PMID:23208885

  17. Assessment and comparative analysis of a rapid diagnostic test (Tubex® for the diagnosis of typhoid fever among hospitalized children in rural Tanzania

    Directory of Open Access Journals (Sweden)

    Shoo Aikande

    2011-05-01

    Full Text Available Abstract Background Typhoid fever remains a significant health problem in many developing countries. A rapid test with a performance comparable to that of blood culture would be highly useful. A rapid diagnostic test for typhoid fever, Tubex®, is commercially available that uses particle separation to detect immunoglobulin M directed towards Salmonella Typhi O9 lipopolysaccharide in sera. Methods We assessed the sensitivity and specificity of the Tubex test among Tanzanian children hospitalized with febrile illness using blood culture as gold standard. Evaluation was done considering blood culture confirmed S. Typhi with non-typhi salmonella (NTS and non - salmonella isolates as controls as well as with non-salmonella isolates only. Results Of 139 samples tested with Tubex, 33 were positive for S. Typhi in blood culture, 49 were culture-confirmed NTS infections, and 57 were other non-salmonella infections. Thirteen hemolyzed samples were excluded. Using all non - S. Typhi isolates as controls, we showed a sensitivity of 79% and a specificity of 89%. When the analysis was repeated excluding NTS from the pool of controls we showed a sensitivity of 79% and a specificity of 97%. There was no significant difference in the test performance using the two different control groups (p > 0.05. Conclusion This first evaluation of the Tubex test in an African setting showed a similar performance to those seen in some Asian settings. Comparison with the earlier results of a Widal test using the same samples showed no significant difference (p > 0.05 for any of the performance indicators, irrespective of the applied control group.

  18. Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy

    International Nuclear Information System (INIS)

    Riley, Craig; Yang, Yong; Li, Tianfang; Zhang, Yongqian; Heron, Dwight E.; Huq, M. Saiful

    2014-01-01

    Purpose: Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients’ treatment plans using a moving phantom driven with a patient-specific respiratory curve. Methods: For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. Results: For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated Rapid

  19. Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy.

    Science.gov (United States)

    Riley, Craig; Yang, Yong; Li, Tianfang; Zhang, Yongqian; Heron, Dwight E; Huq, M Saiful

    2014-01-01

    Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients' treatment plans using a moving phantom driven with a patient-specific respiratory curve. For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated RapidArc therapy. Varied results were

  20. Advanced Vehicle Testing and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Garetson, Thomas [The Clarity Group, Incorporated, Chicago, IL (United States)

    2013-03-31

    The objective of the United States (U.S.) Department of Energy's (DOEs) Advanced Vehicle Testing and Evaluation (AVTE) project was to provide test and evaluation services for advanced technology vehicles, to establish a performance baseline, to determine vehicle reliability, and to evaluate vehicle operating costs in fleet operations.Vehicles tested include light and medium-duty vehicles in conventional, hybrid, and all-electric configurations using conventional and alternative fuels, including hydrogen in internal combustion engines. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing.

  1. Influence of the applied voltage on the Rapid Chloride Migration (RCM) test

    NARCIS (Netherlands)

    Spiesz, P.R.; Brouwers, H.J.H.

    2012-01-01

    This study addresses the influence of the applied voltage (electrical field) on the value of the chloride migration coefficient, as determined with the Rapid Chloride Migration (RCM) test, and on other properties of cement based mortars. It is shown that in the investigated ranges of applied

  2. Evaluation of rapid methods for in-situ characterization of organic contaminant load and biodegradation rates in winery wastewater.

    Science.gov (United States)

    Carvallo, M J; Vargas, I; Vega, A; Pizarro, G; Pizarr, G; Pastén, P

    2007-01-01

    Rapid methods for the in-situ evaluation of the organic load have recently been developed and successfully implemented in municipal wastewater treatment systems. Their direct application to winery wastewater treatment is questionable due to substantial differences between municipal and winery wastewater. We critically evaluate the use of UV-VIS spectrometry, buffer capacity testing (BCT), and respirometry as rapid methods to determine organic load and biodegradation rates of winery wastewater. We tested three types of samples: actual and treated winery wastewater, synthetic winery wastewater, and samples from a biological batch reactor. Not surprisingly, respirometry gave a good estimation of biodegradation rates for substrate of different complexities, whereas UV-VIS and BCT did not provide a quantitative measure of the easily degradable sugars and ethanol, typically the main components of the COD in the influent. However, our results strongly suggest that UV-VIS and BCT can be used to identify and estimate the concentration of complex substrates in the influent and soluble microbial products (SMP) in biological reactors and their effluent. Furthermore, the integration of UV-VIS spectrometry, BCT, and mathematical modeling was able to differentiate between the two components of SMPs: substrate utilization associated products (UAP) and biomass associated products (BAP). Since the effluent COD in biologically treated wastewaters is composed primarily by SMPs, the quantitative information given by these techniques may be used for plant control and optimization.

  3. EU-approved rapid tests for bovine spongiform encephalopathy detect atypical forms: a study for their sensitivities.

    Directory of Open Access Journals (Sweden)

    Daniela Meloni

    Full Text Available Since 2004 it become clear that atypical bovine spongiform encephalopthies (BSEs exist in cattle. Whenever their detection has relied on active surveillance plans implemented in Europe since 2001 by rapid tests, the overall and inter-laboratory performance of these diagnostic systems in the detection of the atypical strains has not been studied thoroughly to date. To fill this gap, the present study reports on the analytical sensitivity of the EU-approved rapid tests for atypical L- and H-type and classical BSE in parallel. Each test was challenged with two dilution series, one created from a positive pool of the three BSE forms according to the EURL standard method of homogenate preparation (50% w/v and the other as per the test kit manufacturer's instructions. Multilevel logistic models and simple logistic models with the rapid test as the only covariate were fitted for each BSE form analyzed as directed by the test manufacturer's dilution protocol. The same schemes, but excluding the BSE type, were then applied to compare test performance under the manufacturer's versus the water protocol. The IDEXX HerdChek ® BSE-scrapie short protocol test showed the highest sensitivity for all BSE forms. The IDEXX® HerdChek BSE-scrapie ultra short protocol, the Prionics®--Check WESTERN and the AJ Roboscreen® BetaPrion tests showed similar sensitivities, followed by the Roche® PrionScreen, the Bio-Rad® TeSeE™ SAP and the Prionics®--Check PrioSTRIP in descending order of analytical sensitivity. Despite these differences, the limit of detection of all seven rapid tests against the different classes of material set within a 2 log(10 range of the best-performing test, thus meeting the European Food Safety Authority requirement for BSE surveillance purposes. These findings indicate that not many atypical cases would have been missed surveillance since 2001 which is important for further epidemiological interpretations of the sporadic character of

  4. Evaluation of the Specificity and Sensitivity of a Potential Rapid Influenza Screening System

    Science.gov (United States)

    2013-01-01

    misuse of antibiotic therapy for treatment of influenza infections. Rapid identification of influenza infections would further reduce transmission of...amplification tests in combination with Type I BESt™ Cassette have been developed and used to rapidly detect other pathogenic microorgan- isms including herpes ... simplex virus types 1 and 2 (Kim et al., 2011), Mycobacterium tuberculosis (Motre et al., 2011), human immunode- ficiency virus (Tang et al., 2010), and

  5. Proficiency tests, Evaluating

    NARCIS (Netherlands)

    Cofino, W.P.; Molenaar, J.; Torfs, P.J.J.F.

    2017-01-01

    Marine monitoring programs provide data that are essential for marine management. The reliability of such data is underpinned by proficiency tests. In the context of Quasimeme, a proficiency testing program for the marine environment, a statistical model has been developed in 2000 to evaluate data

  6. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  7. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  8. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  9. Are Treponema pallidum specific rapid and point-of-care tests for syphilis accurate enough for screening in resource limited settings? Evidence from a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Yalda Jafari

    Full Text Available Rapid and point-of-care (POC tests for syphilis are an invaluable screening tool, yet inadequate evaluation of their diagnostic accuracy against best reference standards limits their widespread global uptake. To fill this gap, a systematic review and meta-analysis was conducted to evaluate the sensitivity and specificity of rapid and POC tests in blood and serum samples against Treponema pallidum (TP specific reference standards.Five electronic databases (1980-2012 were searched, data was extracted from 33 articles, and Bayesian hierarchical models were fit.In serum samples, against a TP specific reference standard point estimates with 95% credible intervals (CrI for the sensitivities of popular tests were: i Determine, 90.04% (80.45, 95.21, ii SD Bioline, 87.06% (75.67, 94.50, iii VisiTect, 85.13% (72.83, 92.57, and iv Syphicheck, 74.48% (56.85, 88.44, while specificities were: i Syphicheck, 99.14% (96.37, 100, ii Visitect, 96.45% (91.92, 99.29, iii SD Bioline, 95.85% (89.89, 99.53, and iv Determine, 94.15% (89.26, 97.66. In whole blood samples, sensitivities were: i Determine, 86.32% (77.26, 91.70, ii SD Bioline, 84.50% (78.81, 92.61, iii Syphicheck, 74.47% (63.94, 82.13, and iv VisiTect, 74.26% (53.62, 83.68, while specificities were: i Syphicheck, 99.58% (98.91, 99.96, ii VisiTect, 99.43% (98.22, 99.98, iii SD Bioline, 97.95%(92.54, 99.33, and iv Determine, 95.85% (92.42, 97.74.Rapid and POC treponemal tests reported sensitivity and specificity estimates comparable to laboratory-based treponemal tests. In resource limited settings, where access to screening is limited and where risk of patients lost to follow up is high, the introduction of these tests has already been shown to improve access to screening and treatment to prevent stillbirths and neonatal mortality due to congenital syphilis. Based on the evidence, it is concluded that rapid and POC tests are useful in resource limited settings with poor access to laboratories or screening

  10. Antigen detection of rabies virus in brain smear using direct Rapid Immunohistochemistry Test

    Directory of Open Access Journals (Sweden)

    Damayanti R

    2014-03-01

    Full Text Available Rabies is zoonotic disease caused by a fatal, neurotropic virus. Rabies virus is classified into the Genus of Lyssavirus under the yang family of Rhabdoviridae. Rabies affecting hot- blooded animals, as well as human. Dogs, cats, monkeys are the vectors or reservoirs for rabies and the virus was transmitted through the saliva after infected animal’s bites. The aim of this study was to conduct rapid diagnosis to detect rabies viral antigen in brain smear using immunohistochemical (IHC method namely direct Rapid Immunohistochemical Test (dRIT. A total number of 119 brain samples were achieved from Bukittinggi Veterinary Laboratory, West Sumatra. Standardisation and validation of the method were compared to Fluorescent Antibody Test (FAT as a golden standard for rabies diagnosis. Results show that dRIT was a very good method, it can be performed within two hours without the need of fluorescent microscope. The samples were tested using FAT and from 119 samples tested, 80 (67.23% samples were positive for rabies and 39 (32.77% samples were negative for rabies whereas using dRIT showed that 78 (65.54% samples were positive for rabies and 41 (34.45% samples were negative for rabies. The dRIT results were validated by comparing them with FAT results as a golden standard for rabies. The relative sensitivity of dRIT to FAT was 97.5% and the relative specificity to FAT was 100% (with Kappa value of 0.976, stated as excellent. The achievement showed that dRIT is very potential diagnostic tool and is highly recommended to be used widely as a rapid diagnosis tool for rabies.

  11. Assessment of test methods for evaluating effectiveness of cleaning flexible endoscopes.

    Science.gov (United States)

    Washburn, Rebecca E; Pietsch, Jennifer J

    2018-06-01

    Strict adherence to each step of reprocessing is imperative to removing potentially infectious agents. Multiple methods for verifying proper reprocessing exist; however, each presents challenges and limitations, and best practice within the industry has not been established. Our goal was to evaluate endoscope cleaning verification tests with particular interest in the evaluation of the manual cleaning step. The results of the cleaning verification tests were compared with microbial culturing to see if a positive cleaning verification test would be predictive of microbial growth. This study was conducted at 2 high-volume endoscopy units within a multisite health care system. Each of the 90 endoscopes were tested for adenosine triphosphate, protein, microbial growth via agar plate, and rapid gram-negative culture via assay. The endoscopes were tested in 3 locations: the instrument channel, control knob, and elevator mechanism. This analysis showed substantial level of agreement between protein detection postmanual cleaning and protein detection post-high-level disinfection at the control head for scopes sampled sequentially. This study suggests that if protein is detected postmanual cleaning, there is a significant likelihood that protein will also be detected post-high-level disinfection. It also infers that a cleaning verification test is not predictive of microbial growth. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Comparison of patient comprehension of rapid HIV pre-test fundamentals by information delivery format in an emergency department setting

    Directory of Open Access Journals (Sweden)

    Clark Melissa A

    2007-09-01

    Full Text Available Abstract Background Two trials were conducted to compare emergency department patient comprehension of rapid HIV pre-test information using different methods to deliver this information. Methods Patients were enrolled for these two trials at a US emergency department between February 2005 and January 2006. In Trial One, patients were randomized to a no pre-test information or an in-person discussion arm. In Trial Two, a separate group of patients were randomized to an in-person discussion arm or a Tablet PC-based video arm. The video, "Do you know about rapid HIV testing?", and the in-person discussion contained identical Centers for Disease Control and Prevention-suggested pre-test information components as well as information on rapid HIV testing with OraQuick®. Participants were compared by information arm on their comprehension of the pre-test information by their score on a 26-item questionnaire using the Wilcoxon rank-sum test. Results In Trial One, 38 patients completed the no-information arm and 31 completed the in-person discussion arm. Of these 69 patients, 63.8% had twelve years or fewer of formal education and 66.7% had previously been tested for HIV. The mean score on the questionnaire for the in-person discussion arm was higher than for the no information arm (18.7 vs. 13.3, p ≤ 0.0001. In Trial Two, 59 patients completed the in-person discussion and 55 completed the video arms. Of these 114 patients, 50.9% had twelve years or fewer of formal education and 68.4% had previously been tested for HIV. The mean score on the questionnaire for the video arm was similar to the in-person discussion arm (20.0 vs. 19.2; p ≤ 0.33. Conclusion The video "Do you know about rapid HIV testing?" appears to be an acceptable substitute for an in-person pre-test discussion on rapid HIV testing with OraQuick®. In terms of adequately informing ED patients about rapid HIV testing, either form of pre-test information is preferable than for patients

  13. Rapid antibiotic susceptibility testing in a microfluidic pH sensor.

    Science.gov (United States)

    Tang, Yanyan; Zhen, Li; Liu, Jingqing; Wu, Jianmin

    2013-03-05

    For appropriate selection of antibiotics in the treatment of pathogen infection, rapid antibiotic susceptibility testing (AST) is urgently needed in clinical practice. This study reports the utilization of a microfluidic pH sensor for monitoring bacterial growth rate in culture media spiked with different kinds of antibiotics. The microfluidic pH sensor was fabricated by integration of pH-sensitive chitosan hydrogel with poly(dimethylsiloxane) (PDMS) microfluidic channels. For facilitating the reflectometric interference spectroscopic measurements, the chitosan hydrogel was coated on an electrochemically etched porous silicon chip, which was used as the substrate of the microfluidic channel. Real-time observation of the pH change in the microchannel can be realized by Fourier transform reflectometric interference spectroscopy (FT-RIFS), in which the effective optical thickness (EOT) was selected as the optical signal for indicating the reversible swelling process of chitosan hydrogel stimulated by pH change. With this microfluidic pH sensor, we demonstrate that confinement of bacterial cells in a nanoliter size channel allows rapid accumulation of metabolic products and eliminates the need for long-time preincubation, thus reducing the whole detection time. On the basis of this technology, the whole bacterial growth curve can be obtained in less than 2 h, and consequently rapid AST can be realized. Compared with conventional methods, the AST data acquired from the bacterial growth curve can provide more detailed information for studying the antimicrobial behavior of antibiotics during different stages. Furthermore, the new technology also provides a convenient method for rapid minimal inhibition concentration (MIC) determination of individual antibiotics or the combinations of antibiotics against human pathogens that will find application in clinical and point-of-care medicine.

  14. National uranium resource evaluation, Rapid City Quadrangle, South Dakota

    International Nuclear Information System (INIS)

    Nanna, R.F.; Milton, E.J.

    1982-04-01

    The Rapid City (1 0 x 2 0 ) Quadrangle, South Dakota, was evaluated for environments favorble for uranium deposits to a depth of 1500 m. Criteria used were those of the National Uranium Resource Evaluation. Field reconnaissance involved the use of hand-held scintillometers to investigate uranium occurrences reported in the literature and anomalies in aerial radiometric surveys, and geochemical samples of stream sediments and well waters. Gamma-ray logs were used to define the favorable environments in the subsurface. Environments favorable for sandstone-type uranium deposits occur in the Inyan Kara Group, the Fox Hills Sandstone, and the Hell Creek Formation. Environments considered unfavorable for uranium deposits include all Precambrian, Paleozoic, Mesozoic, and Tertiary rocks other than those identified as favorable

  15. Incorporating Direct Rapid Immunohistochemical Testing into Large-Scale Wildlife Rabies Surveillance

    Directory of Open Access Journals (Sweden)

    Kevin Middel

    2017-06-01

    Full Text Available Following an incursion of the mid-Atlantic raccoon variant of the rabies virus into southern Ontario, Canada, in late 2015, the direct rapid immunohistochemical test for rabies (dRIT was employed on a large scale to establish the outbreak perimeter and to diagnose specific cases to inform rabies control management actions. In a 17-month period, 5800 wildlife carcasses were tested using the dRIT, of which 307 were identified as rabid. When compared with the gold standard fluorescent antibody test (FAT, the dRIT was found to have a sensitivity of 100% and a specificity of 98.2%. Positive and negative test agreement was shown to be 98.3% and 99.1%, respectively, with an overall test agreement of 98.8%. The average cost to test a sample was $3.13 CAD for materials, and hands-on technical time to complete the test is estimated at 0.55 h. The dRIT procedure was found to be accurate, fast, inexpensive, easy to learn and perform, and an excellent tool for monitoring the progression of a wildlife rabies incursion.

  16. A rapid phenol toxicity test based on photosynthesis and movement of the freshwater flagellate, Euglena agilis Carter

    Energy Technology Data Exchange (ETDEWEB)

    Kottuparambil, Sreejith [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Kim, Youn-Jung [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Department of Marine Science, Incheon National University, Incheon 406 840 (Korea, Republic of); Green-Pioneer (Ltd.), Incheon National University, Incheon 406 840 (Korea, Republic of); Choi, Hoon; Kim, Mi-Sung; Park, Areum; Park, Jihae [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Shin, Woongghi [Department of Biology, Chungnam University, Daejeon 306 764 (Korea, Republic of); Han, Taejun, E-mail: hanalgae@hanmail.net [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Department of Marine Science, Incheon National University, Incheon 406 840 (Korea, Republic of); Green-Pioneer (Ltd.), Incheon National University, Incheon 406 840 (Korea, Republic of)

    2014-10-15

    Highlights: • Rapid phenol toxicity tests (1 h) were developed based on Chl a fluorescence and the movement parameters of Euglena agilis. • Phenol significantly reduced F{sub v}/F{sub m} of PS II and rETRmax with EC50 values of 8.94 and 4.67 mM, respectively. • Among the movement parameters tested, velocity was the most sensitive biomarker with an EC50 of 3.17 mM. • The EC50 values for F{sub v}/F{sub m}, motility, and velocity appear to overlap the environmental permissible levels of phenol. - Abstract: Phenol, a monosubstituted aromatic hydrocarbon with various commercial uses, is a major organic constituent in industrial wastewaters. The ecotoxic action of phenol for aquatic environment is well known. In this study, rapid phenol toxicity tests (1 h) were developed based on chlorophyll a (Chl a) fluorescence and the movement parameters of the freshwater flagellate, Euglena agilis Carter. Phenol significantly reduced the maximum quantum yield (F{sub v}/F{sub m}) of photosystem II (PS II) and the maximum photosynthetic electron transport rate (rETR{sub max}) with median effective concentration (EC{sub 50}) values of 8.94 and 4.67 mM, respectively. Phenol reduced the motility and triggered change in the swimming velocity of the test organism. Among the parameters tested, velocity was the most sensitive biomarker with an EC{sub 50} of 3.17 mM. The EC{sub 50} values for F{sub v}/F{sub m}, motility, and velocity appear to overlap the permitted levels of phenol. In conclusion, the photosynthesis and movement of E. agilis can be fast and sensitive risk assessment parameters for the evaluation of phenol toxicity in municipal and industrial effluents.

  17. GAMBARAN PENGGUNAAN RAPID DIAGNOSTIC TEST PARASIT MALARIA DI DESA PASIRMUKTI KECAMATAN CINEAM KABUPATEN TASIKMALAYA

    Directory of Open Access Journals (Sweden)

    Hubullah Fuadzy

    2013-12-01

    Full Text Available Abstract. High mobility amongst mining workers, demanding officer of Cineam Public Health Center can perform rapid diagnosis to the workers. Nowadays, many techniques are developed to detect the early transmission of malaria, begins from the clinical to the molecular, one of that techniques are Rapid Diagnostic Tests (RDTs. This research has been conducted in the village of Pasirmukti district Cineam, Tasikmalaya in 2012. Objective of this paper is description RDT utilities as rapid diagnosing efforts on families who have family members as mine worker malaria endemic areas. Inclusion criteria for this study were family who have and do not have family members were working as workers in malaria-endemic areas at 2011 or 2012. Respondents were willing to participate in this study would be taken for examination RDT. Respondents were willing to participate in this study amounted to 256 people, and 5 of them positive Plasmodium malaria based on RDTs screening. Respondents who positive for malaria on RDTs test were 4 women with lower education background and work as a housewife, then a men with a background of secondary school education and are currently still as student. RDT is one of the malaria parasite tools which suitable for use in the Pasirmukti Village district Cineam - Tasikmalaya. However, keep in mind on how to storage and use in order to avoid errors both false-positive and false negatives test results.   Keywords: rapid diagnostic tests, malaria, Tasikmalaya Abstrak. Mobilitas yang tinggi penduduk Cineam  menuju wilayah pertambangan emas diluar pulau Jawa, menuntut tenaga kesehatan di Puskesmas Cineam dapat melakukan diagnosa dini penyakit malaria terhadap para pekerja tambang tersebut. Saat ini, banyak dikembangkan teknik untuk mendeteksi penularan penyakit malaria secara dini, mulai dari yang bersifat klinis hingga molekuler, diantaranya adalah Rapid Diagnostic Tests (RDTs. Untuk mengetahui gambaran pemanfaatan RDT di Cineam perlu

  18. The Charlie Sheen Effect on Rapid In-home Human Immunodeficiency Virus Test Sales.

    Science.gov (United States)

    Allem, Jon-Patrick; Leas, Eric C; Caputi, Theodore L; Dredze, Mark; Althouse, Benjamin M; Noar, Seth M; Ayers, John W

    2017-07-01

    One in eight of the 1.2 million Americans living with human immunodeficiency virus (HIV) are unaware of their positive status, and untested individuals are responsible for most new infections. As a result, testing is the most cost-effective HIV prevention strategy and must be accelerated when opportunities are presented. Web searches for HIV spiked around actor Charlie Sheen's HIV-positive disclosure. However, it is unknown whether Sheen's disclosure impacted offline behaviors like HIV testing. The goal of this study was to determine if Sheen's HIV disclosure was a record-setting HIV prevention event and determine if Web searches presage increases in testing allowing for rapid detection and reaction in the future. Sales of OraQuick rapid in-home HIV test kits in the USA were monitored weekly from April 12, 2014, to April 16, 2016, alongside Web searches including the terms "test," "tests," or "testing" and "HIV" as accessed from Google Trends. Changes in OraQuick sales around Sheen's disclosure and prediction models using Web searches were assessed. OraQuick sales rose 95% (95% CI, 75-117; p sales than expected around Sheen's disclosure, surpassing World AIDS Day by a factor of about 7. Moreover, Web searches mirrored OraQuick sales trends (r = 0.79), demonstrating their ability to presage increases in testing. The "Charlie Sheen effect" represents an important opportunity for a public health response, and in the future, Web searches can be used to detect and act on more opportunities to foster prevention behaviors.

  19. Obtaining of a rapid diagnostic test for Cholera, based on latex particles coupled with a monoclonal antibody against Vibrio cholera O1 lipopolysaccharide

    Directory of Open Access Journals (Sweden)

    Fátima Reyes-López

    2015-08-01

    Full Text Available Cholera is an acute contagious intestinal disease caused by ingestion of food or water contaminated with O1 and O139 serotypes of the bacterium Vibrio cholerae. Cholera is characterized by abundant secretory diarrhea leading to dehydration. Death occurs within hours without treatment, so early diagnosis is very important, especially at the beginning of the disease, because it is difficult to differentiate from other acute diarrheal diseases. The diagnostic golden test is the stool culture; however, it does not guarantee a rapid detection of the disease. Rapid tests have been recently developed; they are based on test strips and agglutination with latex particles, which are very effective, but difficult to acquire for their high prices. The objective of this research was to obtain a quick assay based on latex particles coupled with a monoclonal antibody (mAb against V. cholerae O1 lipopolysaccharide obtained in Finlay Institute. Latex particles of 0.8 µm were used in a 10% suspension, and they were coupled to the mAb (0.25 mg/ml for 2 hours at 37°C. The sensitivity, specificity and performance were evaluated in 84 stool samples from patients with presumptive diagnosis of cholera. The diagnostic test obtained showed no cross-reactivity against no-O1 strains and other enteropathogens. Latex diagnostic test showed values of sensitivity, specificity and efficacy of 97.87; 97.29 and 97.6% respectively, very similar to the commercial diagnostic test CTK- Biotech. The latex reagent obtained can be used in the rapid diagnosis of the disease.

  20. Using three-dimensional rapid prototyping in the design and development of orthopaedic screws in standardised pull-out tests.

    Science.gov (United States)

    Leslie, Laura Jane; Connolly, Ashley; Swadener, John G; Junaid, Sarah; Theivendran, Kanthan; Deshmukh, Subodh C

    2018-05-01

    The majority of orthopaedic screws are designed, tested and manufactured by existing orthopaedics companies and are predominantly developed with healthy bone in mind. The timescales and costs involved in the development of a new screw design, for example, for osteoporotic bone, are high. In this study, standard wood screws were used to analyse the concept of using three-dimensional printing, or rapid prototyping, as a viable stage of development in the design of a new bone screw. Six wood screws were reverse engineered and printed in polymeric material using stereolithography. Three of the designs were also printed in Ti6Al4V using direct metal laser sintering; however, these were not of sufficient quality to test further. Both the original metal screws (metal) and polymeric rapid prototyping screws were then tested using standard pull-out tests from low-density polyurethane blocks (Sawbones). Results showed the highest pull-out strengths for screws with the longest thread length and the smallest inner diameter. Of the six screw designs tested, five showed no more than a 17% variance between the metal and rapid prototyping results. A similar pattern of results was shown between the screw designs for both the metal and rapid prototyping screws in five of the six cases. While not producing fully comparable pull-out results to orthopaedic screws, the results from this study do provide evidence of the potential usefulness and cost-effectiveness of rapid prototyping in the early stages of design and testing of orthopaedic screws.

  1. Quantitative analysis of topoisomerase IIα to rapidly evaluate cell proliferation in brain tumors

    International Nuclear Information System (INIS)

    Oda, Masashi; Arakawa, Yoshiki; Kano, Hideyuki; Kawabata, Yasuhiro; Katsuki, Takahisa; Shirahata, Mitsuaki; Ono, Makoto; Yamana, Norikazu; Hashimoto, Nobuo; Takahashi, Jun A.

    2005-01-01

    Immunohistochemical cell proliferation analyses have come into wide use for evaluation of tumor malignancy. Topoisomerase IIα (topo IIα), an essential nuclear enzyme, has been known to have cell cycle coupled expression. We here show the usefulness of quantitative analysis of topo IIα mRNA to rapidly evaluate cell proliferation in brain tumors. A protocol to quantify topo IIα mRNA was developed with a real-time RT-PCR. It took only 3 h to quantify from a specimen. A total of 28 brain tumors were analyzed, and the level of topo IIα mRNA was significantly correlated with its immuno-staining index (p < 0.0001, r = 0.9077). Furthermore, it sharply detected that topo IIα mRNA decreased in growth-inhibited glioma cell. These results support that topo IIα mRNA may be a good and rapid indicator to evaluate cell proliferate potential in brain tumors

  2. Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.

    Science.gov (United States)

    Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R

    2018-01-01

    The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.

  3. Global survey of malaria rapid diagnostic test (RDT) sales, procurement and lot verification practices: assessing the use of the WHO-FIND Malaria RDT Evaluation Programme (2011-2014).

    Science.gov (United States)

    Incardona, Sandra; Serra-Casas, Elisa; Champouillon, Nora; Nsanzabana, Christian; Cunningham, Jane; González, Iveth J

    2017-05-15

    Malaria rapid diagnostic tests (RDTs) play a critical role in malaria case management, and assurance of quality is a key factor to promote good adherence to test results. Since 2007, the World Health Organization (WHO) and the Foundation for Innovative New Diagnostics (FIND) have coordinated a Malaria RDT Evaluation Programme, comprising a pre-purchase performance evaluation (product testing, PT) and a pre-distribution quality control of lots (lot testing, LT), the former being the basis of WHO recommendations for RDT procurement. Comprehensive information on malaria RDTs sold worldwide based on manufacturers' data and linked to independent performance data is currently not available, and detailed knowledge of procurement practices remains limited. The use of the PT/LT Programme results as well as procurement and lot verification practices were assessed through a large-scale survey, gathering product-specific RDT sales and procurement data (2011-14 period) from a total of 32 manufacturers, 12 procurers and 68 National Malaria Control Programmes (NMCPs). Manufacturers' reports showed that RDT sales had more than doubled over the four years, and confirmed a trend towards increased compliance with the WHO procurement criteria (from 83% in 2011 to 93% in 2014). Country-level reports indicated that 74% of NMCPs procured only 'WHO-compliant' RDT products, although procurers' transactions datasets revealed a surprisingly frequent overlap of different products and even product types (e.g., Plasmodium falciparum-only and Plasmodium-pan) in the same year and country (60 and 46% of countries, respectively). Importantly, the proportion of 'non-complying' (i.e., PT low scored or not evaluated) products was found to be higher in the private health care sector than in the public sector (32% vs 5%), and increasing over time (from 22% of private sector sales in 2011 to 39% in 2014). An estimated 70% of the RDT market was covered by the LT programme. The opinion about the PT

  4. Diagnosis of rinderpest in Tanzania by a rapid chromatographic strip-test.

    Science.gov (United States)

    Wambura, P N; Moshy, D W; Mbise, A N; Mollel, G O; Taylor, W P; Anderson, J; Bruning, A

    2000-06-01

    A simple chromatographic strip-test based on Clearview technology, is under development as a pen-side test for the detection of rinderpest antigen in eye swabs taken from cattle in the field. An outbreak of rinderpest occurred in the northern zone of Tanzania from late February to June 1997. The affected cattle exhibited very mild clinical signs, which made clinical diagnosis difficult. One hundred and seven eye swabs were collected from cattle suspected of infection with rinderpest. These were tested in the field using a prototype of the pen-side test and 13 (12.15%) of the samples were found to be positive for the presence of rinderpest antigen. These were confirmed by ICE. The positive cases were predominantly found in the Ngorongoro district. This demonstrates the usefulness of such a simple, rapid pen-side diagnostic assay, particularly when clinically 'mild' strains of rinderpest are present.

  5. Impact of rapid molecular diagnostic tests on time to treatment initiation and outcomes in patients with multidrug-resistant tuberculosis, Tamil Nadu, India.

    Science.gov (United States)

    Nair, Dina; Navneethapandian, Pooranaganga D; Tripathy, Jaya Prasad; Harries, Anthony D; Klinton, Joel S; Watson, Basilea; Sivaramakrishnan, Gomathi N; Reddy, Devarajulu S; Murali, Lakshmi; Natrajan, Mohan; Swaminathan, Soumya

    2016-09-01

    India is replacing culture and drug sensitivity testing (CDST) with rapid molecular tests for diagnosing MDR-TB. We assessed the impact of rapid tests on time to initiation of treatment and outcomes in patients with MDR-TB compared with CDST. A retrospective cohort study involving MDR-TB patients from six districts in Tamil Nadu state, who underwent CDST (2010-2011) and rapid tests (2012-2013). There were 135 patients in the CDST group and 389 in the rapid diagnostic test group. Median time from sputum receipt at the laboratory to initiation of MDR-TB treatment was 130 days (IQR 75-213) in the CDST group and 22 days (IQR 14-38) in the rapid diagnostic test group (p30% in both groups and missing data were higher in CDST (13%) compared with rapid tests (3%). There were significantly higher risks of unfavourable treatment outcomes in males (aRR 1.3, 95% CI 1.1-1.5) and those with treatment initiation delays >30 days (aRR 1.3, 95% CI 1.0-1.6). Rapid molecular diagnostic tests shortened the time to initiate treatment which was associated with reduced unfavourable outcomes in MDR-TB patients. This supports the policy to scale up these tests in India. © The Author 2016. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Evaluation of high pressure Freon decontamination. I. Preliminary tests

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1983-01-01

    High-pressure Freon blasting techniques are being evaluated for applications involving the removal of non-adherent radioactive particulate contamination at SRP. Very little waste is generated by this technique because the used Freon can be easily distilled and reused. One of the principle advantages of this technique is that decontaminated electrical equipment can be returned to service immediately without drying, unlike high-pressure water blasting techniques. Preliminary scoutin tests evaluating high-pressure Freon blasting for decontamination at SRP were carried out at Quadrex Co., Oak Ridge, TN, October 12 and 13. DWPF-type contamination (raw sludge plus volatiles) and separations area-type contamination (diluted boiling point (47.6 0 C) allow it to rapidly separate from higher boiling contaminants via distillation with filtration to remove particulate material, and distillation with condensation, the solvent may be recovered for indefinite reuse while reducing the radioactive waste to a minimum. 3 references, 5 figures, 6 tables

  7. Evaluation of twenty rapid antigen tests for the detection of human influenza A H5N1, H3N2, H1N1, and B viruses.

    Science.gov (United States)

    Taylor, Janette; McPhie, Kenneth; Druce, Julian; Birch, Chris; Dwyer, Dominic E

    2009-11-01

    Twenty rapid antigen assays were compared for their ability to detect influenza using dilutions of virus culture supernatants from human isolates of influenza A H5N1 (clade 1 and 2 strains), H3N2 and H1N1 viruses, and influenza B. There was variation amongst the rapid antigen assays in their ability to detect different influenza viruses. Six of the 12 assays labeled as distinguishing between influenza A and B had comparable analytical sensitivities for detecting both influenza A H5N1 strains, although their ability to detect influenza A H3N2 and H1N1 strains varied. The two assays claiming H5 specificity did not detect either influenza A H5N1 strains, and the two avian influenza-specific assays detected influenza A H5N1, but missed some influenza A H3N2 virus supernatants. Clinical trials of rapid antigen tests for influenza A H5N1 are limited. For use in a pandemic where novel influenza strains are circulating (such as the current novel influenza A H1N1 09 virus), rapid antigen tests should ideally have comparable sensitivity and specificity for the new strains as for co-circulating seasonal influenza strains.

  8. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe; Du, Dan

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

  9. Rapid Antimicrobial Susceptibility Testing of Bacillus anthracis, Yersinia pestis, and Burkholderia pseudomallei by Use of Laser Light Scattering Technology.

    Science.gov (United States)

    Bugrysheva, Julia V; Lascols, Christine; Sue, David; Weigel, Linda M

    2016-06-01

    Rapid methods to determine antimicrobial susceptibility would assist in the timely distribution of effective treatment or postexposure prophylaxis in the aftermath of the release of bacterial biothreat agents such as Bacillus anthracis, Yersinia pestis, or Burkholderia pseudomallei Conventional susceptibility tests require 16 to 48 h of incubation, depending on the bacterial species. We evaluated a method that is based on laser light scattering technology that measures cell density in real time. We determined that it has the ability to rapidly differentiate between growth (resistant) and no growth (susceptible) of several bacterial threat agents in the presence of clinically relevant antimicrobials. Results were available in 10 h of incubation. Use of laser scattering technology decreased the time required to determine antimicrobial susceptibility by 50% to 75% for B. anthracis, Y. pestis, and B. pseudomallei compared to conventional methods. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  10. Rapid diagnostic testing for community-acquired pneumonia: can innovative technology for clinical microbiology be exploited?

    Science.gov (United States)

    Yu, Victor L; Stout, Janet E

    2009-12-01

    Two nonsynchronous events have affected the management of community-acquired pneumonia (CAP): spiraling empiricism for CAP and the "golden era" of clinical microbiology. The development of broad-spectrum antibiotics has led to widespread empiric use without ascertaining the etiology of the infecting microbe. Unfortunately, this approach clashes with the second event, which is the advent of molecular-based microbiology that can identify the causative pathogen rapidly at the point of care. The urinary antigen is a most effective rapid test that has allowed targeted therapy for Legionnaire disease at the point of care. The high specificity (> 90%) allows the clinician to administer appropriate anti-Legionella therapy based on a single rapid test; however, its low sensitivity (76%) means that a notable number of cases of Legionnaire disease will go undiagnosed if other tests, especially culture, are not performed. Further, culture for Legionella is not readily available. If a culture is not performed, epidemiologic identification of the source of the bacterium cannot be ascertained by molecular fingerprinting of the patient and the putative source strain. We recommend resurrection of the basic principles of infectious disease, which are to identify the microbial etiology of the infection and to use narrow, targeted antimicrobial therapy. To reduce antimicrobial overuse with subsequent antimicrobial resistance, these basic principles must be applied in concert with traditional and newer tests in the clinical microbiology laboratory.

  11. Detection of cut-off point for rapid automized naming test in good readers and dyslexics

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-01-01

    Full Text Available Background and Aim: Rapid automized naming test is an appropriate tool to diagnose learning disability even before teaching reading. This study aimed to detect the cut-off point of this test for good readers and dyslexics.Methods: The test has 4 parts including: objects, colors, numbers and letters. 5 items are repeated on cards randomly for 10 times. Children were asked to name items rapidly. We studied 18 dyslexic students and 18 age-matched good readers between 7 and 8 years of age at second and third grades of elementary school; they were recruited by non-randomize sampling into 2 groups: children with developmental dyslexia from learning disabilities centers with mean age of 100 months, and normal children with mean age of 107 months from general schools in Tehran. Good readers selected from the same class of dyslexics.Results: The area under the receiver operating characteristic curve was 0.849 for letter naming, 0.892 for color naming, 0.971 for number naming, 0.887 for picture naming, and 0.965 totally. The overall sensitivity and specificity was 1 and was 0.79, respectively. The highest sensitivity and specificity were related to number naming (1 and 0.90, respectively.Conclusion: Findings showed that the rapid automized naming test could diagnose good readers from dyslexics appropriately.

  12. Accuracy of individual rapid tests for serodiagnosis of gambiense sleeping sickness in West Africa.

    Directory of Open Access Journals (Sweden)

    Vincent Jamonneau

    2015-02-01

    Full Text Available Individual rapid tests for serodiagnosis (RDT of human African trypanosomiasis (HAT are particularly suited for passive screening and surveillance. However, so far, no large scale evaluation of RDTs has been performed for diagnosis of Trypanosoma brucei gambiense HAT in West Africa. The objective of this study was to assess the diagnostic accuracy of 2 commercial HAT-RDTs on stored plasma samples from West Africa.SD Bioline HAT and HAT Sero-K-Set were performed on 722 plasma samples originating from Guinea and Côte d'Ivoire, including 231 parasitologically confirmed HAT patients, 257 healthy controls, and 234 unconfirmed individuals whose blood tested antibody positive in the card agglutination test but negative by parasitological tests. Immune trypanolysis was performed as a reference test for trypanosome specific antibody presence. Sensitivities in HAT patients were respectively 99.6% for SD Bioline HAT, and 99.1% for HAT Sero-K-Set, specificities in healthy controls were respectively 87.9% and 88.3%. Considering combined positivity in both RDTs, increased the specificity significantly (p ≤ 0.0003 to 93.4%, while 98.7% sensitivity was maintained. Specificities in controls were 98.7-99.6% for the combination of one or two RDTs with trypanolysis, maintaining a sensitivity of at least 98.1%.The observed specificity of the single RDTs was relatively low. Serial application of SD Bioline HAT and HAT Sero-K-Set might offer superior specificity compared to a single RDT, maintaining high sensitivity. The combination of one or two RDTs with trypanolysis seems promising for HAT surveillance.

  13. Rapid diagnostic tests as a source of DNA for Plasmodium species-specific real-time PCR

    Directory of Open Access Journals (Sweden)

    Van Esbroeck Marjan

    2011-03-01

    Full Text Available Abstract Background This study describes the use of malaria rapid diagnostic tests (RDTs as a source of DNA for Plasmodium species-specific real-time PCR. Methods First, the best method to recover DNA from RDTs was investigated and then the applicability of this DNA extraction method was assessed on 12 different RDT brands. Finally, two RDT brands (OptiMAL Rapid Malaria Test and SDFK60 malaria Ag Plasmodium falciparum/Pan test were comprehensively evaluated on a panel of clinical samples submitted for routine malaria diagnosis at ITM. DNA amplification was done with the 18S rRNA real-time PCR targeting the four Plasmodium species. Results of PCR on RDT were compared to those obtained by PCR on whole blood samples. Results Best results were obtained by isolating DNA from the proximal part of the nitrocellulose component of the RDT strip with a simple DNA elution method. The PCR on RDT showed a detection limit of 0.02 asexual parasites/μl, which was identical to the same PCR on whole blood. For all 12 RDT brands tested, DNA was detected except for one brand when a low parasite density sample was applied. In RDTs with a plastic seal covering the nitrocellulose strip, DNA extraction was hampered. PCR analysis on clinical RDT samples demonstrated correct identification for single species infections for all RDT samples with asexual parasites of P. falciparum (n = 60, Plasmodium vivax (n = 10, Plasmodium ovale (n = 10 and Plasmodium malariae (n = 10. Samples with only gametocytes were detected in all OptiMAL and in 10 of the 11 SDFK60 tests. None of the negative samples (n = 20 gave a signal by PCR on RDT. With PCR on RDT, higher Ct-values were observed than with PCR on whole blood, with a mean difference of 2.68 for OptiMAL and 3.53 for SDFK60. Mixed infections were correctly identified with PCR on RDT in 4/5 OptiMAL tests and 2/5 SDFK60 tests. Conclusions RDTs are a reliable source of DNA for Plasmodium real-time PCR. This study demonstrates the

  14. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  15. Test, measurement and evaluation with the mine boot test and evaluation system

    CSIR Research Space (South Africa)

    Ramaloko, PM

    2014-09-01

    Full Text Available Protective footwear that mitigates the shock transferred to the victim’s leg during an antipersonnel landmine blast need to be evaluated to verify their protection levels. The Mine Boot Test and Evaluation System which include a surrogate lower leg...

  16. The Evaluator Effect in Usability Tests

    DEFF Research Database (Denmark)

    Jacobsen, Niels Ebbe; Hertzum, Morten; John, Bonnie E.

    1998-01-01

    Usability tests are applied in industry to evaluate systems and in research as a yardstick for other usability evaluation methods. However, one potential threat to the reliability of usability tests has been left unaddressed: the evaluator effect. In this study, four evaluators analyzed four vide...

  17. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    Science.gov (United States)

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests

  18. A Survey on Use of Rapid Tests and Tuberculosis Diagnostic Practices by Primary Health Care Providers in South Africa: Implications for the Development of New Point-of-Care Tests.

    Directory of Open Access Journals (Sweden)

    Malika Davids

    Full Text Available Effective infectious disease control requires early diagnosis and treatment initiation. Point-of-care testing offers rapid turn-around-times, facilitating same day clinical management decisions. To maximize the benefits of such POC testing programs, we need to understand how rapid tests are used in everyday clinical practice.In this cross-sectional survey study, 400 primary healthcare providers in two cities in South Africa were interviewed on their use of rapid tests in general, and tuberculosis diagnostic practices, between September 2012 and June 2013. Public healthcare facilities were selected using probability-sampling techniques and private healthcare providers were randomly selected from the Health Professional Council of South Africa list. To ascertain differences between the two healthcare sectors 2-sample z-tests were used to compare sample proportions.The numbers of providers interviewed were equally distributed between the public (n = 200 and private sector (n = 200. The most frequently reported tests in the private sector include blood pressure (99.5%, glucose finger prick (89.5% and urine dipstick (38.5%; and in the public sector were pregnancy (100%, urine dipstick (100%, blood pressure (100%, glucose finger prick (99% and HIV rapid test (98%. The majority of TB testing occurs in the public sector, where significantly more providers prefer Xpert MTB/RIF assay, the designated clinical TB diagnostic tool by the national TB program, as compared to the private sector (87% versus 71%, p-value >0.0001. Challenges with regard to TB diagnosis included the long laboratory turn-around-time, difficulty in obtaining sputum samples and lost results. All providers indicated that a new POC test for TB should be rapid and cheap, have good sensitivity and specificity, ease of sample acquisition, detect drug-resistance and work in HIV-infected persons.The existing centralized laboratory services, poor quality assurance, and lack of staff capacity

  19. Rapid identification of HPV 16 and 18 by multiplex nested PCR-immunochromatographic test.

    Science.gov (United States)

    Kuo, Yung-Bin; Li, Yi-Shuan; Chan, Err-Cheng

    2015-02-01

    Human papillomavirus (HPV) types 16 and 18 are known to be high-risk viruses that cause cervical cancer. An HPV rapid testing kit that could help physicians to make early and more informed decisions regarding patient care is needed urgently but not yet available. This study aimed to develop a multiplex nested polymerase chain reaction-immunochromatographic test (PCR-ICT) for the rapid identification of HPV 16 and 18. A multiplex nested PCR was constructed to amplify the HPV 16 and 18 genotype-specific L1 gene fragments and followed by ICT which coated with antibodies to identify rapidly the different PCR products. The type-specific gene regions of high-risk HPV 16 and 18 could be amplified successfully by multiplex nested PCR at molecular sizes of approximately 99 and 101bp, respectively. The capture antibodies raised specifically against the moleculars labeled on the PCR products could be detected simultaneously both HPV 16 and 18 in one strip. Under optimal conditions, this PCR-ICT assay had the capability to detect HPV in a sample with as low as 100 copies of HPV viral DNA. The PCR-ICT system has the advantage of direct and simultaneous detection of two high-risk HPV 16 and 18 DNA targets in one sample, which suggested a significant potential of this assay for clinical application. Copyright © 2014. Published by Elsevier B.V.

  20. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing

    Directory of Open Access Journals (Sweden)

    Biglino Giovanni

    2013-01-01

    Full Text Available Abstract Background Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930® is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. Methods The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm, keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient’s suitability for percutaneous pulmonary valve intervention. Results The distensibility of the material was identified in a range from 6.5 × 10-3 mmHg-1 for the 0.6 mm case, to 3.0 × 10-3 mmHg-1 for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Conclusion Values of distensibility, compared with literature data, show that Tango

  1. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing.

    Science.gov (United States)

    Biglino, Giovanni; Verschueren, Peter; Zegels, Raf; Taylor, Andrew M; Schievano, Silvia

    2013-01-16

    Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930 is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR) images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm), keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT) of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient's suitability for percutaneous pulmonary valve intervention. The distensibility of the material was identified in a range from 6.5 × 10(-3) mmHg(-1) for the 0.6 mm case, to 3.0 × 10(-3) mmHg(-1) for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Values of distensibility, compared with literature data, show that TangoPlus is suitable for manufacturing arterial phantoms, with

  2. Evaluation of a rapid screening test for rifampicin resistance in re ...

    African Journals Online (AJOL)

    Sensitivity, specificity and overall accuracy of the phage test were determined compared with gold standard culture and DST. Discrepant results were resolved by molecular detection of mutations conferring rifampicin resistance. The proportion of rifampicin-resistant strains that were MDR was also determined. Results.

  3. Microbiological evaluation of a new growth-based approach for rapid detection of methicillin-resistant Staphylococcus aureus

    NARCIS (Netherlands)

    von Eiff, Christof; Maas, Dominik; Sander, Gunnar; Friedrich, Alexander W; Peters, Georg; Becker, Karsten

    OBJECTIVES: Recently, a rapid screening tool for methicillin-resistant Staphylococcus aureus (MRSA) has been introduced that applies a novel detection technology allowing the rapid presence or absence of MRSA to be determined from an enrichment broth after only a few hours of incubation. To evaluate

  4. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  5. Potential applications of rapid/elementary nonparametric statistical techniques (NST) to electrochemical problems

    International Nuclear Information System (INIS)

    Fahidy, Thomas Z.

    2009-01-01

    A major advantage of NST lies in the unimportance of the probability distribution of observations. In this paper, the sign test, the rank-sum test, the Kruskal-Wallis test, the Friedman test, and the runs test illustrate the potential of certain rapid NST for the evaluation of electrochemical process performance.

  6. Comparative field performance and adherence to test results of four malaria rapid diagnostic tests among febrile patients more than five years of age in Blantyre, Malawi

    Directory of Open Access Journals (Sweden)

    San Joaquin Miguel

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostics tests (RDTs can increase availability of laboratory-based diagnosis and improve the overall management of febrile patients in malaria endemic areas. In preparation to scale-up RDTs in health facilities in Malawi, an evaluation of four RDTs to help guide national-level decision-making was conducted. Methods A cross sectional study of four histidine rich-protein-type-2- (HRP2 based RDTs at four health centres in Blantyre, Malawi, was undertaken to evaluate the sensitivity and specificity of RDTs, assess prescriber adherence to RDT test results and explore operational issues regarding RDT implementation. Three RDTs were evaluated in only one health centre each and one RDT was evaluated in two health centres. Light microscopy in a reference laboratory was used as the gold standard. Results A total of 2,576 patients were included in the analysis. All of the RDTs tested had relatively high sensitivity for detecting any parasitaemia [Bioline SD (97%, First response malaria (92%, Paracheck (91%, ICT diagnostics (90%], but low specificity [Bioline SD (39%, First response malaria (42%, Paracheck (68%, ICT diagnostics (54%]. Specificity was significantly lower in patients who self-treated with an anti-malarial in the previous two weeks (odds ratio (OR 0.5; p-value 15 years old (OR 0.4, p-value Conclusions The results of this evaluation, combined with other published data and global recommendations, have been used to select RDTs for national scale-up. In addition, the study identified some key issues that need to be further delineated: the low field specificity of RDTs, variable RDT performance by different cadres of health workers and the need for a robust quality assurance system. Close monitoring of RDT scale-up will be needed to ensure that RDTs truly improve malaria case management.

  7. Numerical and experimental flow analysis in centifluidic systems for rapid allergy screening tests

    Directory of Open Access Journals (Sweden)

    Dethloff Manuel

    2015-09-01

    Full Text Available For the development of the automated processing of a membrane-based rapid allergy test, the flow characteristics in one part of the test, the reagents module, are analysed. This module consists of a multichannel system with several inputs and one output. A return flow from one input channel into another should be avoided. A valveless module with pointed channels at an angle of 12° is analysed with numerical and experimental methods with regard to the flow characteristics.

  8. Acoustic transfer function of cavity and its application to rapid evaluation of sound field at low frequency band

    Institute of Scientific and Technical Information of China (English)

    YIN Gang; CHEN Hualing; HU Xuanli; HUANG Xieqing

    2001-01-01

    A new method to obtain numerical solution of Acoustic Transfer Function (ATF) by BEM is presented. For a simply supported panel backed by a rectangular cavity at low frequency band (0-200 Hz), the frequency property of ATF is analyzed. The relation between the accuracy of the rapid evaluation of sound field and the discretization schemes of the vibrational panel is discussed. The result shows that the method to obtain ATF and the rapid evaluation of sound field using the ATF is suitable to low frequency band. If an appropriate discretization scheme is choosed based on the frequency involved and the effort to obtain ATF, the accuracy of the rapid evaluation of sound field is acceptable.

  9. Use and limitations of malaria rapid diagnostic testing by community health workers in war-torn Democratic Republic of Congo.

    Science.gov (United States)

    Hawkes, Michael; Katsuva, Jean Paul; Masumbuko, Claude K

    2009-12-23

    Accurate and practical malaria diagnostics, such as immunochromatographic rapid diagnostic tests (RDTs), have the potential to avert unnecessary treatments and save lives. Volunteer community health workers (CHWs) represent a potentially valuable human resource for expanding this technology to where it is most needed, remote rural communities in sub-Saharan Africa with limited health facilities and personnel. This study reports on a training programme for CHWs to incorporate RDTs into their management strategy for febrile children in the Democratic Republic of Congo, a tropical African setting ravaged by human conflict. Prospective cohort study, satisfaction questionnaire and decision analysis. Twelve CHWs were trained to safely and accurately perform and interpret RDTs, then successfully implemented rapid diagnostic testing in their remote community in a cohort of 357 febrile children. CHWs were uniformly positive in evaluating RDTs for their utility and ease of use. However, high malaria prevalence in this cohort (93% by RDTs, 88% by light microscopy) limited the cost-effectiveness of RDTs compared to presumptive treatment of all febrile children, as evidenced by findings from a simplified decision analysis. CHWs can safely and effectively use RDTs in their management of febrile children; however, cost-effectiveness of RDTs is limited in zones of high malaria prevalence.

  10. Use and limitations of malaria rapid diagnostic testing by community health workers in war-torn Democratic Republic of Congo

    Directory of Open Access Journals (Sweden)

    Katsuva Jean

    2009-12-01

    Full Text Available Abstract Background Accurate and practical malaria diagnostics, such as immunochromatographic rapid diagnostic tests (RDTs, have the potential to avert unnecessary treatments and save lives. Volunteer community health workers (CHWs represent a potentially valuable human resource for expanding this technology to where it is most needed, remote rural communities in sub-Saharan Africa with limited health facilities and personnel. This study reports on a training programme for CHWs to incorporate RDTs into their management strategy for febrile children in the Democratic Republic of Congo, a tropical African setting ravaged by human conflict. Methods Prospective cohort study, satisfaction questionnaire and decision analysis. Results Twelve CHWs were trained to safely and accurately perform and interpret RDTs, then successfully implemented rapid diagnostic testing in their remote community in a cohort of 357 febrile children. CHWs were uniformly positive in evaluating RDTs for their utility and ease of use. However, high malaria prevalence in this cohort (93% by RDTs, 88% by light microscopy limited the cost-effectiveness of RDTs compared to presumptive treatment of all febrile children, as evidenced by findings from a simplified decision analysis. Conclusions CHWs can safely and effectively use RDTs in their management of febrile children; however, cost-effectiveness of RDTs is limited in zones of high malaria prevalence.

  11. A methodology to enable rapid evaluation of aviation environmental impacts and aircraft technologies

    Science.gov (United States)

    Becker, Keith Frederick

    of multiple aircraft families. The results of experimentation led to a down selection to the best approach to use to rapidly characterize the performance of the commercial fleet for accurately in the context of acceptability of current fleet evaluation methods. The parametric correction factor and average replacement approaches were shown to be successful in capturing reference fleet results as well as fleet performance with variations in operations. The best-in-class replacement approach was shown to be unacceptable as a model for the larger fleet in each of the scenarios tested. Finally, the average replacement approach was the only one that was successful in capturing the impact of technologies on a larger fleet. These results are meaningful because they show that it is possible to calculate the fuel burn and emissions of a larger fleet with a reduced number of physics-based models within acceptable bounds of accuracy. At the same time, the physics-based modeling also provides the ability to evaluate the impact of technologies on fleet-level fuel burn and emissions metrics. The value of such a capability is that multiple future fleet scenarios involving changes in both aircraft operations and technology levels may now be rapidly evaluated to inform and equip policy makers of the implications of impacts of changes on fleet-level metrics.

  12. Rapid, automated, nonradiometric susceptibility testing of Mycobacterium tuberculosis complex to four first-line antituberculous drugs used in standard short-course chemotherapy

    DEFF Research Database (Denmark)

    Johansen, Isik Somuncu; Thomsen, Vibeke Østergaard; Marjamäki, Merja

    2004-01-01

    The increasing prevalence of drug-resistant tuberculosis necessitates rapid and accurate susceptibility testing. The nonradiometric BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT) system for susceptibility testing was evaluated on 222 clinical Mycobacterium tuberculosis complex isolates...... for isoniazid, rifampin, and ethambutol. Fifty-seven of the isolates were tested for pyrazinamide. Results were compared to those of radiometric BACTEC 460 system and discrepancies were resolved by the agar proportion method. We found an overall agreement of 99.0% for isoniazid, 99.5% for rifampin, 98.......2% for ethambutol, and 100% for pyrazinamide. After resolution of discrepancies, MGIT yielded no false susceptibility for rifampin and isoniazid. Although turnaround times were comparable, MGIT provides an advantage as inoculation can be done on any weekday as the growth is monitored automatically. The automated...

  13. Rapidity correlations test stochastic hydrodynamics

    International Nuclear Information System (INIS)

    Zin, C; Gavin, S; Moschelli, G

    2017-01-01

    We show that measurements of the rapidity dependence of transverse momentum correlations can be used to determine the characteristic time τ π that dictates the rate of isotropization of the stress energy tensor, as well as the shear viscosity ν = η/sT . We formulate methods for computing these correlations using second order dissipative hydrodynamics with noise. Current data are consistent with τ π /ν ∼ 10 but targeted measurements can improve this precision. (paper)

  14. Corrosion of metals in wood : comparing the results of a rapid test method with long-term exposure tests across six wood treatments

    Science.gov (United States)

    Samuel L. Zelinka; Donald S. Stone

    2011-01-01

    This paper compares two methods of measuring the corrosion of steel and galvanized steel in wood: a long-term exposure test in solid wood and a rapid test method where fasteners are electrochemically polarized in extracts of wood treated with six different treatments. For traditional wood preservatives, the electrochemical extract method correlates with solid wood...

  15. Evaluation of the Kodak Surecell Chlamydia test for the laboratory diagnosis of adult inclusion conjunctivitis.

    Science.gov (United States)

    Tantisira, J G; Kowalski, R P; Gordon, Y J

    1995-07-01

    The Kodak Surecell Chlamydia test, a rapid enzyme immunoassay, has been reported to be highly sensitive (93%) and specific (96%) for detecting chlamydial lipopolysaccharide antigen in conjunctival specimens from infants, but has not been evaluated previously in adult conjunctival specimens. This study was designed to determine the efficacy of the Kodak Surecell Chlamydia test for the laboratory diagnosis of adult inclusion conjunctivitis. Twenty Chlamydia culture-positive conjunctival specimens from adults (true-positives) and 20 true-negative specimens were tested with the Kodak Surecell Chlamydia test. The Kodak Surecell Chlamydia test was 40% (8/20) sensitive, 100% (20/20) specific, and 70% (28/40) efficient. This study indicates that the Kodak Surecell Chlamydia test, though highly specific, is less sensitive in its ability to diagnose chlamydial conjunctivitis in adults than has been reported previously in infants.

  16. Design, implementation and evaluation of a training programme for school teachers in the use of malaria rapid diagnostic tests as part of a basic first aid kit in southern Malawi.

    Science.gov (United States)

    Witek-McManus, Stefan; Mathanga, Don P; Verney, Allison; Mtali, Austin; Ali, Doreen; Sande, John; Mwenda, Reuben; Ndau, Saidi; Mazinga, Charles; Phondiwa, Emmanuel; Chimuna, Tiyese; Melody, David; Roschnik, Natalie; Brooker, Simon J; Halliday, Katherine E

    2015-09-17

    With increasing levels of enrolment, primary schools present a pragmatic opportunity to improve the access of school children to timely diagnosis and treatment of malaria, increasingly recognised as a major health problem within this age group. The expanded use of malaria rapid diagnostic tests (RDTs) and artemisinin combination therapy (ACT) by community health workers (CHWs) has raised the prospect of whether teachers can provide similar services for school children. We describe and evaluate the training of primary school teachers to use a first aid kit containing malaria RDTs and ACT for the diagnosis and treament of uncomplicated malaria in school children in southern Malawi. We outline the development of the intervention as: (1) conception and design, (2) pilot training, (3) final training, and (4) 7-month follow up. The training materials were piloted at a four-day workshop in July 2013 following their design at national stakeholders meetings. The evaluation of the pilot training and materials were assessed in relation to increased knowledge and skill sets using checklist evaluations and questionnaires, the results of which informed the design of a final seven-day training programme held in December 2013. A follow up of trained teachers was carried out in July 2014 following 7 months of routine implementation. A total of 15 teachers were evaluated at four stages: pilot training, two weeks following pilot, final training and seven months following final training. A total of 15 and 92 teachers were trained at the pilot and final training respectively. An average of 93 % of the total steps required to use RDTs were completed correctly at the final training, declining to 87 % after 7 months. All teachers were observed correctly undertaking safe blood collection and handling, accurate RDT interpretation, and correct dispensing of ACT. The most commonly observed errors were a failure to wait 20 minutes before reading the test result, and adding an incorrect volume

  17. The diagnostic accuracy of the rapid dipstick test to predict asymptomatic urinary tract infection of pregnancy.

    Science.gov (United States)

    Eigbefoh, J O; Isabu, P; Okpere, E; Abebe, J

    2008-07-01

    Untreated urinary tract infection can have devastating maternal and neonatal effects. Thus, routine screening for bacteriuria is advocated. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy with the gold standard of urine microscopy, culture and sensitivity acting as the control. The urine dipstick test uses the leucocyte esterase, nitrite and test for protein singly and in combination. The result of the dipstick was compared with the gold standard, urine microscopy, culture and sensitivity using confidence interval for proportions. The reliability and validity of the urine dipstick was also evaluated. Overall, the urine dipstick test has a poor correlation with urine culture (p = 0.125, CI 95%). The same holds true for individual components of the dipstick test. The overall sensitivity of the urine dipstick test was poor at 2.3%. Individual sensitivity of the various components varied between 9.1% for leucocyte esterase and the nitrite test to 56.8% for leucocyte esterase alone. The other components of the dipstick test, the test of nitrite, test for protein and combination of the test (leucocyte esterase, nitrite and proteinuria) appear to decrease the sensitivity of the leucocyte esterase test alone. The ability of the urine dipstick test to correctly rule out urinary tract infection (specificity) was high. The positive predictive value for the dipstick test was high, with the leucocyte esterase test having the highest positive predictive value compared with the other components of the dipstick test. The negative predictive value (NPV) was expectedly highest for the leucocyte esterase test alone with values higher than the other components of the urine dipstick test singly and in various combinations. Compared with the other parameters of the urine dipstick test, singly and in combination, leucocyte esterase appears to be the most accurate (90.25%). The dipstick test has a

  18. Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea

    Directory of Open Access Journals (Sweden)

    Frantz Jean Louis

    2017-03-01

    Full Text Available Background: Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT for Ebola antigens could expand diagnostic capacity for Ebola virus disease. Objectives: The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. Methods: The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. Results: There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. Conclusions: Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion.

  19. Testing of a simplified LED based vis/NIR system for rapid ripeness evaluation of white grape (Vitis vinifera L.) for Franciacorta wine.

    Science.gov (United States)

    Giovenzana, Valentina; Civelli, Raffaele; Beghi, Roberto; Oberti, Roberto; Guidetti, Riccardo

    2015-11-01

    The aim of this work was to test a simplified optical prototype for a rapid estimation of the ripening parameters of white grape for Franciacorta wine directly in field. Spectral acquisition based on reflectance at four wavelengths (630, 690, 750 and 850 nm) was proposed. The integration of a simple processing algorithm in the microcontroller software would allow to visualize real time values of spectral reflectance. Non-destructive analyses were carried out on 95 grape bunches for a total of 475 berries. Samplings were performed weekly during the last ripening stages. Optical measurements were carried out both using the simplified system and a portable commercial vis/NIR spectrophotometer, as reference instrument for performance comparison. Chemometric analyses were performed in order to extract the maximum useful information from optical data. Principal component analysis (PCA) was performed for a preliminary evaluation of the data. Correlations between the optical data matrix and ripening parameters (total soluble solids content, SSC; titratable acidity, TA) were carried out using partial least square (PLS) regression for spectra and using multiple linear regression (MLR) for data from the simplified device. Classification analysis were also performed with the aim of discriminate ripe and unripe samples. PCA, MLR and classification analyses show the effectiveness of the simplified system in separating samples among different sampling dates and in discriminating ripe from unripe samples. Finally, simple equations for SSC and TA prediction were calculated. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Development of a prototype for dissolved CO2 rapid measurement and preliminary tests

    Science.gov (United States)

    Li, Meng; Guo, Jinjia; Zhang, Zhihao; Luo, Zhao; Qin, Chuan; Zheng, Ronger

    2017-10-01

    The measurements of dissolved CO2 in seawater is of great significance for the study of global carbon cycle. At present, the commercial sensors used for dissolved CO2 measurements are mostly equipped with permeable membranes for the purpose of gas-liquid separation, with the advantages of easy operation, low cost, etc.. However, most of these devices measure CO2 after reaching gas equilibrium, so it takes a few minutes to respond, which limited its applications in rapid measurements. In this paper, a set of prototype was developed for the rapid measurements of dissolved CO2. The system was built basing the direct absorption TDLAS. To detect the CO2 absorption line located at 4991.26 cm-1 , a fiber-coupled DFB laser operating at 2004 nm was selected as the light source. A Herriott type multi-pass cavity with an effective optical path length of 10 m and an inner volume of 90 mL was used for absorption measurements. A detection limit of 26 μatm can be obtained with this compact cavity. To realize the rapid measurements of dissolved CO2, a degasser with high degassing rate was necessary. A hollow fiber membrane with a large permeable area used in this paper can achieve degassing rate up to 2.88 kPa/min. Benefitted from the high degassing rate of the degasser and high sensitivity of the compact TDLAS system, a rapid measurement of dissolved CO2 in water can be achieved within 1s time, and the response time of the prototype when the dissolved CO2 concentration changed abruptly in actual measurement was 15 s. To evaluate the performance of the prototype, comparison measurements were carried out with a commercial mass spectrometer. The dissolved CO2 in both seawater and tap-water was measured, and the experimental results showed good consistent trends with R2 of 0.973 and 0.931. The experimental results proved the feasibility of dissolved CO2 rapid measurement. In the near future, more system evaluation experiments will be carried out and the system will be further

  1. Frosted branch angiitis associated with rapidly progressive glomerulonephritis.

    Directory of Open Access Journals (Sweden)

    Gupta Amod

    2002-01-01

    Full Text Available Simultaneous occurrence of frosted branch angiitis and immune-mediated rapidly progressive glomerulonephritis is reported. The two diseases possibly share a common immune mechanism. Patients of frosted branch angiitis should undergo complete systemic evaluation including renal function tests even if the patient is systemically asymptomatic.

  2. Integrated Rapid-Diagnostic-Test Reader Platform on a Cellphone

    Science.gov (United States)

    Mudanyali, Onur; Dimitrov, Stoyan; Sikora, Uzair; Padmanabhan, Swati; Navruz, Isa; Ozcan, Aydogan

    2012-01-01

    We demonstrate a cellphone based Rapid-Diagnostic-Test (RDT) reader platform that can work with various lateral flow immuno-chromatographic assays and similar tests to sense the presence of a target analyte in a sample. This compact and cost-effective digital RDT reader, weighing only ~65 grams, mechanically attaches to the existing camera unit of a cellphone, where various types of RDTs can be inserted to be imaged in reflection or transmission modes under light-emitting-diode (LED) based illumination. Captured raw images of these tests are then digitally processed (within less than 0.2 sec/image) through a smart application running on the cellphone for validation of the RDT as well as for automated reading of its diagnostic result. The same smart application running on the cellphone then transmits the resulting data, together with the RDT images and other related information (e.g., demographic data) to a central server, which presents the diagnostic results on a world-map through geo-tagging. This dynamic spatio-temporal map of various RDT results can then be viewed and shared using internet browsers or through the same cellphone application. We tested this platform using malaria, tuberculosis (TB) as well as HIV RDTs by installing it on both Android based smart-phones as well as an iPhone. Providing real-time spatio-temporal statistics for the prevalence of various infectious diseases, this smart RDT reader platform running on cellphones might assist health-care professionals and policy makers to track emerging epidemics worldwide and help epidemic preparedness. PMID:22596243

  3. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  4. Development and evaluation of an immunochromatographic strip test based on the recombinant UL51 protein for detecting antibody against duck enteritis virus

    Directory of Open Access Journals (Sweden)

    Sun Tao

    2010-10-01

    Full Text Available Abstract Background Duck enteritis virus (DEV infection causes substantial economic losses to the worldwide duck-producing areas. The monitoring of DEV-specific antibodies is a key to evaluate the effect of DEV vaccine and develop rational immunization programs. Thus, in this study, an immunochromatographic strip (ICS test was developed for detecting DEV serum antibodies. Results The ICS test is based on membrane chromatography, and uses both the purified recombinant UL51 protein conjugated with colloidal gold and goat anti-rabbit IgG conjugated with colloidal gold as tracers, the purified recombinant UL51 protein as the capture reagent at the test line, and rabbit IgG as the capture reagent at the control line. The specificity of the ICS was evaluated by sera against DEV, Duck hepatitis virus (DHV, Riemerella anatipestifer (RA, Duck E. coli, Muscovy duck parvovirus (MPV, or Duck Influenza viruses (DIV. Only sera against DEV showed the strong positive results. In order to determine the sensitivity of the ICS, anti-DEV serum diluted serially was tested, and the minimum detection limit of 1:128 was obtained. The ICS components, which are provided in a sealed package, require no refrigeration and are stable for 12 months. To evaluate the effect of the ICS, 110 duck serum samples collected from several non-immune duck flocks were simultaneously tested by the ICS test, enzyme-linked immunosorbent assay (ELISA and neutralization test (NT. The results showed that the sensitivity of the ICS test was almost consistent with ELISA and much higher than NT, has low cost, and is rapid (15 min and easy to perform with no requirement of specialized equipment, reagent or technicians. Conclusions In this work, we successfully developed a simple and rapid ICS test for detecting DEV serum antibodies for the first time. The ICS test was high specific and sensitive for the rapid detection of anti-DEV antibodies, and has great potential to be used for the serological

  5. Provider-related barriers to rapid HIV testing in U.S. urban non-profit community clinics, community-based organizations (CBOs) and hospitals.

    Science.gov (United States)

    Bogart, Laura M; Howerton, Devery; Lange, James; Setodji, Claude Messan; Becker, Kirsten; Klein, David J; Asch, Steven M

    2010-06-01

    We examined provider-reported barriers to rapid HIV testing in U.S. urban non-profit community clinics, community-based organizations (CBOs), and hospitals. 12 primary metropolitan statistical areas (PMSAs; three per region) were sampled randomly, with sampling weights proportional to AIDS case reports. Across PMSAs, all 671 hospitals and a random sample of 738 clinics/CBOs were telephoned for a survey on rapid HIV test availability. Of the 671 hospitals, 172 hospitals were randomly selected for barriers questions, for which 158 laboratory and 136 department staff were eligible and interviewed in 2005. Of the 738 clinics/CBOs, 276 were randomly selected for barriers questions, 206 were reached, and 118 were eligible and interviewed in 2005-2006. In multivariate models, barriers regarding translation of administrative/quality assurance policies into practice were significantly associated with rapid HIV testing availability. For greater rapid testing diffusion, policies are needed to reduce administrative barriers and provide quality assurance training to non-laboratory staff.

  6. Rapid testing and identification of actuator using dSPACE real-time emulator

    Science.gov (United States)

    Xie, Daocheng; Wang, Zhongwei; Zeng, Qinghua

    2011-10-01

    To solve the problem of model identification of actuator in control system design of aerocraft, testing system based on dSPACE emulator is established, sending testing signal and receiving feedback voltage are realized using dSPACE interactive cards, communication between signal generating equipment and feedback voltage acquisition equipment is synchronized. This paper introduces the hardware architecture and key technologies of the simulation system. Constructing, downloading and calculating of the testing model is finished using dSPACE emulator, D/A transfer of testing signal is realized using DS2103 card, DS2002 card transfer the feedback voltage to digital value. Filtering module is added to the signal acquisition, for reduction of noise interference in the A/D channel. Precision of time and voltage is improved by setting acquisition period 1ms. The data gathered is recorded and displayed with Controldesk tools. The response of four actuators under different frequency are tested, frequency-domain analysis is done using least square method, the model of actuator is identified, simulation data fits well with real response of the actuator. The testing system created with dSPACE emulator satisfies the rapid testing and identification of actuator.

  7. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC).

    Science.gov (United States)

    Sarkodie, F; Hassall, O; Owusu-Dabo, E; Owusu-Ofori, S; Bates, I; Bygbjerg, I C; Owusu-Ofori, A; Harritshøj, L H; Ullum, H

    2017-02-01

    Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma reagin (RPR) test at Komfo Anokye Teaching Hospital (KATH), Ghana. From February 2014 to January 2015, 5 mL of venous blood samples were taken from 16 016 blood donors and tested with a treponemal RDT; 5 mL of venous blood was taken from 526 consenting initial syphilis sero-reactive blood donors. These RDT reactive samples were confirmed with an algorithm, applying the Vitros ® /Abbott-Architect ® algorithm as gold standard. A total of 478 of 526 RDT reactive donors were confirmed positive for syphilis, making a PPV of 90·9%. Of the 172 (32·7%) donors who were also RPR positive, 167 were confirmed, resulting in a PPV of 97·1%. The PPV of the combined RDT and RPR (suspected active syphilis) testing algorithm was highest among donors at an enhanced risk of syphilis, family/replacement donors (99·9%), and among voluntary donors above 25 years (98·6%). Screening of blood donors by combining syphilis RDT and RPR with relatively good PPV may provide a reasonable technology for LMIC that has a limited capacity for testing and can contribute to the improvement of blood safety with a minimal loss of donors. © 2016 British Blood Transfusion Society.

  8. Accuracy and user-acceptability of HIV self-testing using an oral fluid-based HIV rapid test.

    Directory of Open Access Journals (Sweden)

    Oon Tek Ng

    Full Text Available BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW testing, participants' ability to interpret sample results and user-acceptability of self-tests in Singapore. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%, negative in 5 (2.6%, and invalid in 1 (0.5%. Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%, positive in 1 (0.1%, and invalid in 2 (0.3%. Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7% and specificity of 99.9% (95% CI: 99.6% to 100%. When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. CONCLUSIONS/SIGNIFICANCE: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as

  9. Evaluating different approaches to non-destructive nitrogen status diagnosis of rice using portable RapidSCAN active canopy sensor.

    Science.gov (United States)

    Lu, Junjun; Miao, Yuxin; Shi, Wei; Li, Jingxin; Yuan, Fei

    2017-10-26

    RapidSCAN is a new portable active crop canopy sensor with three wavebands in red, red-edge, and near infrared spectral regions. The objective of this study was to determine the potential and practical approaches of using this sensor for non-destructive diagnosis of rice nitrogen (N) status. Sixteen plot experiments and ten on-farm experiments were conducted from 2014 to 2016 in Jiansanjiang Experiment Station of the China Agricultural University and Qixing Farm in Northeast China. Two mechanistic and three semi-empirical approaches using the sensor's default vegetation indices, normalized difference vegetation index and normalized difference red edge, were evaluated in comparison with the top performing vegetation indices selected from 51 tested indices. The results indicated that the most practical and stable method of using the RapidSCAN sensor for rice N status diagnosis is to calculate N sufficiency index with the default vegetation indices and then to estimate N nutrition index non-destructively (R 2  = 0.50-0.59). This semi-empirical approach achieved a diagnosis accuracy rate of 59-76%. The findings of this study will facilitate the application of the RapidSCAN active sensor for rice N status diagnosis across growth stages, cultivars and site-years, and thus contributing to precision N management for sustainable intensification of agriculture.

  10. Evaluating the evidence: direct-to-consumer screening tests advertised online.

    Science.gov (United States)

    Lovett, Kimberly M; Mackey, Timothy K; Liang, Bryan A

    2012-09-01

    Unsupervised online direct-to-consumer (DTC) access to medical services has rapidly expanded to medical screening tests, which have not been critically evaluated for their evidence basis. The objective of this study is to identify the scope of online-advertised DTC screening tests, outline the evidence for use of available DTC testing and suggest regulatory reform to address the relevant issues. An observational study of website advertisements, testing services and counselling/follow-up services for DTC testing was conducted. Data were collected from websites between 4 April and 1 June 2011. Each website was assessed for tests offered, advertised indications and availability of counselling/follow-up services. Advertised testing indications were compared with US Preventive Services Task Force recommendations and/or specialty guidelines and categorized as Supported, Against, Insufficient Evidence or No Guidance. Of 20 companies identified as offering DTC screening tests, 95% (19/20) do not clearly offer pretest counselling, post-test counselling and/or test follow-up. One hundred and twenty-seven different tests were identified. Only 19/127 (15%) could be Supported for screening in a target group selected for testing; 38/127 (30%) were given recommendations to avoid use in specific target group(s) selected for testing ('Against recommendations'); 29/127 (23%) had Insufficient Evidence of value, and for 64/127 (50%) No Guidance could be given. Only 4/127 (3%) tests were Supported for general screening use. Virtually all identified medical tests advertised and offered DTC are not recommended for use in screening by evidence-based guidelines. Limited oversight may lead to inaccurate self-diagnosis, treatment and wasted health resources.

  11. Safety of a rapid diagnostic protocol with accelerated stress testing.

    Science.gov (United States)

    Soremekun, Olan A; Hamedani, Azita; Shofer, Frances S; O'Conor, Katie J; Svenson, James; Hollander, Judd E

    2014-02-01

    Most patients at low to intermediate risk for an acute coronary syndrome (ACS) receive a 12- to 24-hour "rule out." Recently, trials have found that a coronary computed tomographic angiography-based strategy is more efficient. If stress testing were performed within the same time frame as coronary computed tomographic angiography, the 2 strategies would be more similar. We tested the hypothesis that stress testing can safely be performed within several hours of presentation. We performed a retrospective cohort study of patients presenting to a university hospital from January 1, 2009, to December 31, 2011, with potential ACS. Patients placed in a clinical pathway that performed stress testing after 2 negative troponin values 2 hours apart were included. We excluded patients with ST-elevation myocardial infarction or with an elevated initial troponin. The main outcome was safety of immediate stress testing defined as the absence of death or acute myocardial infarction (defined as elevated troponin within 24 hours after the test). A total of 856 patients who presented with potential ACS were enrolled in the clinical pathway and included in this study. Patients had a median age of 55.0 (interquartile range, 48-62) years. Chest pain was the chief concern in 86%, and pain was present on arrival in 73% of the patients. There were no complications observed during the stress test. There were 0 deaths (95% confidence interval, 0%-0.46%) and 4 acute myocardial infarctions within 24 hours (0.5%; 95% confidence interval, 0.14%-1.27%). The peak troponins were small (0.06, 0.07, 0.07, and 0.19 ng/mL). Patients who present to the ED with potential ACS can safely undergo a rapid diagnostic protocol with stress testing. © 2013.

  12. Maintenance proficiency evaluation test bank

    International Nuclear Information System (INIS)

    Maier, Loran

    2003-01-01

    The Maintenance Proficiency Evaluation Test Bank (MPETB) is an Electric Power Research Institute- (EPRJ-) operated, utility-sponsored means of developing, maintaining, and disseminating secure, high-quality written and performance maintenance proficiency tests. EPRTs charter is to ensure that all tests and test items that go into the Test Bank have been validated, screened for reliability, and evaluated to high standards of psychometric excellence. Proficiency tests of maintenance personnel.(mechanics, electricians, and instrumentation and control [I and C] technicians) are most often used to determine if an experienced employee is capable of performing maintenance tasks without further training. Such tests provide objective evidence for decisions to exempt an employee from what, for the employee, is unnecessary training. This leads to considerable savings in training costs and increased productivity because supervisors can assign personnel to tasks at which their competence is proven. The ultimate objective of proficiency evaluation is to ensure that qualified maintenance personnel are available to meet the maintenance requirements of the plant Numerous task-specific MPE tests (both written and performance) have been developed and validated using the EPRI MPE methodology by the utilities participating in the MPETB project A task-specific MPE consists of a multiple-choice written examination and a multi-step performance evaluation that can be used to assess an individual's present knowledge and skill level for a given maintenance task. The MPETB contains MPEs and test items for the mechanical, electrical, and I and C classifications that are readily available to participating utilities. Presently, utilities are placing emphasis on developing MPEs to evaluate outage-related maintenance tasks that demonstrate the competency and qualifications of plant and contractor personnel before the start of outage work. Utilities are also using the MPE methodology and process to

  13. A comparative study of rapid test and routine methods for the measurement of cardiac markers in patients with suspected acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    gholamreza Shahsavari

    2014-06-01

    Conclusion: The present results showed that the rapid cTnI test is very specific but not sensitive for AMI diagnosis while rapid CK-MB test is neither sensitive nor specific for AMI dignosis in patients with acute chest pain.

  14. Evaluation of Gamma Interferon and Antibody Tuberculosis Tests in Alpacas

    Science.gov (United States)

    Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin

    2012-01-01

    We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a “test package,” although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations. PMID:22914362

  15. Unexpectedly high leprosy seroprevalence detected using a random surveillance strategy in midwestern Brazil: A comparison of ELISA and a rapid diagnostic test.

    Science.gov (United States)

    Frade, Marco Andrey C; de Paula, Natália A; Gomes, Ciro M; Vernal, Sebastian; Bernardes Filho, Fred; Lugão, Helena B; de Abreu, Marilda M M; Botini, Patrícia; Duthie, Malcolm S; Spencer, John S; Soares, Rosa Castália F R; Foss, Norma T

    2017-02-01

    Leprosy diagnosis is mainly based on clinical evaluation, although this approach is difficult, especially for untrained physicians. We conducted a temporary campaign to detect previously unknown leprosy cases in midwestern Brazil and to compare the performance of different serological tests. A mobile clinic was stationed at the main bus terminal in Brasília, Brazil. Volunteers were quizzed and given a clinical exam to allow categorization as either patients, known contacts of patients or non-contacts, and blood was collected to determine anti-PGL-I and anti-LID-1 antibody titers by ELISA and by the NDO-LID rapid test. New cases of leprosy and the impact of performing this broad random surveillance strategy were evaluated. Accuracy values and concordance between the test results were evaluated among all groups. Four hundred thirty-four individuals were evaluated, and 44 (10.1%) were diagnosed with leprosy. Borderline forms were the most frequent presentation. Both tests presented higher positivity in those individuals with multibacillary disease. Serological tests demonstrated specificities arround 70% for anti-PGL-1 and anti-LID ELISA; and arround 40% for NDO-LID. Sensitivities ranged from 48 to 62%. A substantial agreement between NDO-LID and ELISA with concomitant positive results was found within leprosy patients (Kappa index = 0.79 CI95% 0.36-1.22). The unexpectedly high leprosy prevalence in this population indicates ongoing community-based exposure to Mycobacterium leprae antigens and high rates of subclinical infection. All tests showed low specificity and sensitivity values and therefore cannot be considered for use as stand-alone diagnostics. Rather, considering their positivity among MB patients and non-patients, these tests can be considered effective tools for screening and identifying individuals at high risk who might benefit from regular monitoring.

  16. Test characteristics of two rapid antigen detection tests (SD FK50 and SD FK60 for the diagnosis of malaria in returned travellers

    Directory of Open Access Journals (Sweden)

    Van Esbroeck Marjan

    2009-05-01

    Full Text Available Abstract Background Two malaria rapid diagnostic tests were evaluated in a travel clinic setting: the SD FK50 Malaria Ag Plasmodium falciparum test (a two-band test and the SD FK60 Malaria Ag P. falciparum/Pan test (a three-band test. Methods A panel of stored whole blood samples (n = 452 and n = 614 for FK50 and FK60, respectively from returned travellers was used. The reference method was microscopy with PCR in case of discordant results. Results For both tests, overall sensitivity for the detection of P. falciparum was 93.5%, reaching 97.6% and 100% at parasite densities above 100 and 1,000/μl respectively. Overall sensitivities for Plasmodium vivax, Plasmodium ovale and Plasmodium malariae for the FK60 test were 87.5%, 76.3% and 45.2%, but they reached 92.6% and 90.5% for P. vivax and P. ovale at parasite densities above 500/μl. Specificities were above 95% for all species and both tests when corrected by PCR, with visible histidine-rich protein-2 lines for P. malariae (n = 3 and P. vivax and P. ovale (1 sample each. Line intensities were reproducible and correlated to parasite densities. The FK60 tests provided clues to estimate parasite densities for P. falciparum below or above 1,000/μl. Conclusion Both the FK50 and FK60 performed well for the diagnosis of P. falciparum in the present setting, and the FK60 for the diagnosis of P. vivax and P. ovale at parasite densities > 500/μl. The potential use of the FK60 as a semi-quantitative estimation of parasite density needs to be further explored.

  17. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    Science.gov (United States)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  18. Non-reactive HIV-1 Rapid Tests after Sustained Viral Suppression Following Antiretroviral Therapy Initiation During Primary Infection.

    Science.gov (United States)

    Stefic, Karl; Novelli, Sophie; Mahjoub, Nadia; Seng, Remonie; Molina, Jean-Michel; Cheneau, Christine; Barin, Francis; Chaix, Marie-Laure; Meyer, Laurence; Delaugerre, Constance

    2018-03-02

    We assessed the impact of early antiretroviral treatment (ART) on HIV antibody detection by rapid tests in 44 individuals after several years of successful ART. HIV self-tests and point-of-care tests were negative in respectively 30% and 7-9% of cases. These data reinforce the message that patients should never be retested after entering HIV care.

  19. Can the Bruckner test be used as a rapid screening test to detect significant refractive errors in children?

    Directory of Open Access Journals (Sweden)

    Kothari Mihir

    2007-01-01

    Full Text Available Purpose: To assess the suitability of Brückner test as a screening test to detect significant refractive errors in children. Materials and Methods: A pediatric ophthalmologist prospectively observed the size and location of pupillary crescent on Brückner test as hyperopic, myopic or astigmatic. This was compared with the cycloplegic refraction. Detailed ophthalmic examination was done for all. Sensitivity, specificity, positive predictive value and negative predictive value of Brückner test were determined for the defined cutoff levels of ametropia. Results: Ninety-six subjects were examined. Mean age was 8.6 years (range 1 to 16 years. Brückner test could be completed for all; the time taken to complete this test was 10 seconds per subject. The ophthalmologist identified 131 eyes as ametropic, 61 as emmetropic. The Brückner test had sensitivity 91%, specificity 72.8%, positive predictive value 85.5% and negative predictive value 83.6%. Of 10 false negatives four had compound hypermetropic astigmatism and three had myopia. Conclusions: Brückner test can be used to rapidly screen the children for significant refractive errors. The potential benefits from such use may be maximized if programs use the test with lower crescent measurement cutoffs, a crescent measurement ruler and a distance fixation target.

  20. Rapid susceptibility testing and microcolony analysis of Candida spp. cultured and imaged on porous aluminum oxide.

    Directory of Open Access Journals (Sweden)

    Colin J Ingham

    Full Text Available BACKGROUND: Acquired resistance to antifungal agents now supports the introduction of susceptibility testing for species-drug combinations for which this was previously thought unnecessary. For pathogenic yeasts, conventional phenotypic testing needs at least 24 h. Culture on a porous aluminum oxide (PAO support combined with microscopy offers a route to more rapid results. METHODS: Microcolonies of Candida species grown on PAO were stained with the fluorogenic dyes Fun-1 and Calcofluor White and then imaged by fluorescence microscopy. Images were captured by a charge-coupled device camera and processed by publicly available software. By this method, the growth of yeasts could be detected and quantified within 2 h. Microcolony imaging was then used to assess the susceptibility of the yeasts to amphotericin B, anidulafungin and caspofungin (3.5 h culture, and voriconazole and itraconazole (7 h culture. SIGNIFICANCE: Overall, the results showed good agreement with EUCAST (86.5% agreement; n = 170 and E-test (85.9% agreement; n = 170. The closest agreement to standard tests was found when testing susceptibility to amphotericin B and echinocandins (88.2 to 91.2% and the least good for the triazoles (79.4 to 82.4%. Furthermore, large datasets on population variation could be rapidly obtained. An analysis of microcolonies revealed subtle effects of antimycotics on resistant strains and below the MIC of sensitive strains, particularly an increase in population heterogeneity and cell density-dependent effects of triazoles. Additionally, the method could be adapted to strain identification via germ tube extension. We suggest PAO culture is a rapid and versatile method that may be usefully adapted to clinical mycology and has research applications.

  1. Evaluation of the potassium adsorption capacity of a potassium adsorption filter during rapid blood transfusion.

    Science.gov (United States)

    Matsuura, H; Akatsuka, Y; Muramatsu, C; Isogai, S; Sugiura, Y; Arakawa, S; Murayama, M; Kurahashi, M; Takasuga, H; Oshige, T; Yuba, T; Mizuta, S; Emi, N

    2015-05-01

    The concentration of extracellular potassium in red blood cell concentrates (RCCs) increases during storage, leading to risk of hyperkalemia. A potassium adsorption filter (PAF) can eliminate the potassium at normal blood transfusion. This study aimed to investigate the potassium adsorption capacity of a PAF during rapid blood transfusion. We tested several different potassium concentrations under a rapid transfusion condition using a pressure bag. The adsorption rates of the 70-mEq/l model were 76·8%. The PAF showed good potassium adsorption capacity, suggesting that this filter may provide a convenient method to prevent hyperkalemia during rapid blood transfusion. © 2015 International Society of Blood Transfusion.

  2. Rapid bacterial antibiotic susceptibility test based on simple surface-enhanced Raman spectroscopic biomarkers

    Science.gov (United States)

    Liu, Chia-Ying; Han, Yin-Yi; Shih, Po-Han; Lian, Wei-Nan; Wang, Huai-Hsien; Lin, Chi-Hung; Hsueh, Po-Ren; Wang, Juen-Kai; Wang, Yuh-Lin

    2016-03-01

    Rapid bacterial antibiotic susceptibility test (AST) and minimum inhibitory concentration (MIC) measurement are important to help reduce the widespread misuse of antibiotics and alleviate the growing drug-resistance problem. We discovered that, when a susceptible strain of Staphylococcus aureus or Escherichia coli is exposed to an antibiotic, the intensity of specific biomarkers in its surface-enhanced Raman scattering (SERS) spectra drops evidently in two hours. The discovery has been exploited for rapid AST and MIC determination of methicillin-susceptible S. aureus and wild-type E. coli as well as clinical isolates. The results obtained by this SERS-AST method were consistent with that by the standard incubation-based method, indicating its high potential to supplement or replace existing time-consuming methods and help mitigate the challenge of drug resistance in clinical microbiology.

  3. Study on the chloride migration coefficient obtained following different Rapid Chloride Migration (RCM) test guidelines

    NARCIS (Netherlands)

    Spiesz, P.R.; Brouwers, H.J.H.; Uzoegbo, H.C.; Schmidt, W.

    2013-01-01

    This work presents the differences in the available Rapid Chloride Migration (RCM) test guidelines, and their influence on the values of the chloride migration coefficients DRCM, obtained following these guidelines. It is shown that the differences between the guidelines are significant and concern

  4. Impact of Rapid Susceptibility Testing and Antibiotic Selection Strategy on the Emergence and Spread of Antibiotic Resistance in Gonorrhea.

    Science.gov (United States)

    Tuite, Ashleigh R; Gift, Thomas L; Chesson, Harrell W; Hsu, Katherine; Salomon, Joshua A; Grad, Yonatan H

    2017-11-27

    Increasing antibiotic resistance limits treatment options for gonorrhea. We examined the impact of a hypothetical point-of-care (POC) test reporting antibiotic susceptibility profiles on slowing resistance spread. A mathematical model describing gonorrhea transmission incorporated resistance emergence probabilities and fitness costs associated with resistance based on characteristics of ciprofloxacin (A), azithromycin (B), and ceftriaxone (C). We evaluated time to 1% and 5% prevalence of resistant strains among all isolates with the following: (1) empiric treatment (B and C), and treatment guided by POC tests determining susceptibility to (2) A only and (3) all 3 antibiotics. Continued empiric treatment without POC testing was projected to result in >5% of isolates being resistant to both B and C within 15 years. Use of either POC test in 10% of identified cases delayed this by 5 years. The 3 antibiotic POC test delayed the time to reach 1% prevalence of triply-resistant strains by 6 years, whereas the A-only test resulted in no delay. Results were less sensitive to assumptions about fitness costs and test characteristics with increasing test uptake. Rapid diagnostics reporting antibiotic susceptibility may extend the usefulness of existing antibiotics for gonorrhea treatment, but ongoing monitoring of resistance patterns will be critical. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  5. Rapid drug susceptibility test of mycobacterium tuberculosis by bioluminescence sensor

    Science.gov (United States)

    Lu, Bin; Xu, Shunqing; Chen, Zifei; Zhou, Yikai

    2001-09-01

    With the persisting increase of drug-resistant stains of M. Tuberculosis around the world, rapid and sensitive detection of antibiotic of M. Tuberculosis is becoming more and more important. In the present study, drug susceptibility of M. tuberculosis were detected by recombination mycobacteriophage combined with bioluminescence sensor. It is based on the use of recombination mycobacteriophage which can express firefly luciferase when it infects viable mycobacteria, and can effectively produce quantifiable photon. Meanwhile, in mycobacterium cells treated with active antibiotic, no light is observed. The emitted light is recorded by a bioluminscence sensor, so the result of drug-resistant test can be determined by the naked eye. 159 stains of M. tuberculosis were applied to this test on their resistant to rifampin, streptomycin and isoniazid. It is found that the agreement of this assay with Liewenstein- Jensen slat is: rifampin 95.60 percent, isoniazid 91.82 percent, streptomycin 88.68 percent, which showed that it is a fast and practical method to scene and detect drug resistant of mycobacterium stains.

  6. Utility of a rapid immunochromatographic strip test in detecting canine parvovirus infection compared with polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Sundaran S. Tinky

    2015-04-01

    Full Text Available Aim: The present study was undertaken to detect the presence of canine parvovirus (CPV in fecal samples of diarrheic dogs by conventional polymerase chain reaction (PCR and immunochromatographic (IC strip test and to compare the diagnostic potential of these tests. Materials and Methods: A total of 50 fecal samples collected from diarrheic dogs suspected for CPV infection were subjected to PCR using CPV-555 primer amplifying the gene coding for the VP1 protein. These samples were also tested by IC strip test using a commercial rapid Ag test kit. The results were statistically analyzed using McNemar test. Results: A total of 22 samples (44% were detected as positive by PCR, which yielded a specific amplicon of 583 bp. In IC strip test, 18 (36% samples were found to be positive. The sensitivity of the test as compared to PCR was found to be 72.22% and specificity was 92.86%. Positive predictive value and negative predictive value of IC strip test was found to be 88.89% and 81.25%, respectively. Statistical analysis of the results of PCR and IC assay using McNemar test revealed no significant difference (p>0.05. Conclusion: The IC strip test could be employed as a rapid field level diagnostic tool for the diagnosis of canine parvoviral diarrhea.

  7. Component evaluation testing and analysis algorithms.

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Darren M.; Merchant, Bion John

    2011-10-01

    The Ground-Based Monitoring R&E Component Evaluation project performs testing on the hardware components that make up Seismic and Infrasound monitoring systems. The majority of the testing is focused on the Digital Waveform Recorder (DWR), Seismic Sensor, and Infrasound Sensor. In order to guarantee consistency, traceability, and visibility into the results of the testing process, it is necessary to document the test and analysis procedures that are in place. Other reports document the testing procedures that are in place (Kromer, 2007). This document serves to provide a comprehensive overview of the analysis and the algorithms that are applied to the Component Evaluation testing. A brief summary of each test is included to provide the context for the analysis that is to be performed.

  8. Exclusion and diagnosis of pulmonary embolism by a rapid ELISA D-dimer test and noninvasive imaging techniques within the context of a clinical model.

    Science.gov (United States)

    Michiels, J J; Pattynama, P M

    2000-01-01

    A negative rapid ELISA D-dimer test alone in out-patients with a low to moderate clinical probability (CP) on pulmonary embolism (PE) is predicted to safely exclude pulmonary embolism. The combination of a negative rapid ELISA D-dimer test and a low to moderate CP on PE followed by compression ultrasonography (CUS) for the detection of deep vein thrombosis (DVT) is safe and cost-effective as it reduces the need for noninvasive imaging techniques to about 50% to 60% of outpatients with suspected PE. A high probability ventilation-perfusion (VP) scan or a positive spiral CT consistent with PE and the detection of DVT by CUS are currently considered to be clear indications for anticoagulant treatment. Subsequent pulmonary angiography (PA) is the gold standard diagnostic strategy to exclude or diagnose PE in suspected outpatients with a negative CUS, a positive rapid ELISA D-dimer test, and a nondiagnostic VP scan or negative spiral CT to prevent overtreatment with anticoagulants. However, the willingness of clinicians and the availability of resources to perform PA is restricted, a fact that has provided an impetus for clinical investigators to search for alternative noninvasive strategies to exclude or detect venous thromboembolism (VTE). Serial CUS testing for the detection of DVT in patients with a low to moderate CP on PE and a nondiagnostic VP scan or negative spiral CT is predicted to be safe and will reduce the need for PA to less than 10% or even less than 5%. This noninvasive serial CUS strategy restricts the need for invasive PA to a minor group of patients (spiral CT and a high CP on PE. Prospective evaluations are warranted to implement and to validate the advantages and the disadvantages of the various combinations of noninvasive strategies and to compare serial CUS testing versus PA in randomized clinical management studies of outpatients with suspected pulmonary embolism.

  9. Development of rapid, continuous calibration techniques and implementation as a prototype system for civil engineering materials evaluation

    International Nuclear Information System (INIS)

    Scott, M. L.; Gagarin, N.; Mekemson, J. R.; Chintakunta, S. R.

    2011-01-01

    Until recently, civil engineering material calibration data could only be obtained from material sample cores or via time consuming, stationary calibration measurements in a limited number of locations. Calibration data are used to determine material propagation velocities of electromagnetic waves in test materials for use in layer thickness measurements and subsurface imaging. Limitations these calibration methods impose have been a significant impediment to broader use of nondestructive evaluation methods such as ground-penetrating radar (GPR). In 2006, a new rapid, continuous calibration approach was designed using simulation software to address these measurement limitations during a Federal Highway Administration (FHWA) research and development effort. This continuous calibration method combines a digitally-synthesized step-frequency (SF)-GPR array and a data collection protocol sequence for the common midpoint (CMP) method. Modeling and laboratory test results for various data collection protocols and materials are presented in this paper. The continuous-CMP concept was finally implemented for FHWA in a prototype demonstration system called the Advanced Pavement Evaluation (APE) system in 2009. Data from the continuous-CMP protocol is processed using a semblance/coherency analysis to determine material propagation velocities. Continuously calibrated pavement thicknesses measured with the APE system in 2009 are presented. This method is efficient, accurate, and cost-effective.

  10. Interim Results of a National Test of the Rapid Assessment of Hospital Procurement Barriers in Donation (RAPiD)

    Science.gov (United States)

    Traino, H. M.; Alolod, G. P.; Shafer, T.; Siminoff, L. A.

    2012-01-01

    Organ donation remains a major public health challenge with over 114 000 people on the waitlist in the United States. Among other factors, extant research highlights the need to improve the identification and timely referral of potential donors by hospital health-care providers (HCPs) to organ procurement organizations (OPOs). We implemented a national test of the Rapid Assessment of hospital Procurement barriers in Donation (RAPiD) to identify assets and barriers to the organ donation and patient referral processes; assess hospital–OPO relationships and offer tailored recommendations for improving these processes. Having partnered with seven OPOs, data were collected at 70 hospitals with high donor potential in the form of direct observations and interviews with 2358 HCPs. We found that donation attitudes and knowledge among HCPs were high, but use of standard referral criteria was lacking. Significant differences were found in the donation-related attitudes, knowledge and behaviors of physicians and emergency department staff as compared to other staff in intensive care units with high organ donor potential. Also, while OPO staff were generally viewed positively, they were often perceived as outsiders rather than members of healthcare teams. Recommendations for improving the referral and donation processes are discussed. PMID:22900761

  11. Development of a Rapid Immunodiagnostic Test for Pork Components in Raw Beef and Chicken Meats: a Preliminary Study

    Directory of Open Access Journals (Sweden)

    S. N. Depamede

    2011-08-01

    Full Text Available A rapid immunodiagnostic test that provides visual evidence of the presence of pork components in raw beef and chicken meats was developed. Colloidal gold was prepared and conjugated with anti-Swine IgG polyclonal antibody. Immunochromatographic test strips were produced, and then were used to test laboratory adulterated raw meat samples. The samples consisted adulteration meat, immunodiagnostic, pork, rapid test of pork-in-beef, or pork-in-chicken at 1/0; 1/100; 1/1,000; 1/5,000; 1/10,000 (w/w adulteration levels that were extracted in phosphate-buffered saline. Raw beef and chicken meats without pork were included as controls. Analysis was completed in 10 min. Detection limit was 1/5,000 (w/w, although 1/10,000 was also observed. This immunodiagnostic tests can be conveniently applied to detect low levels of pork components in raw beef and chicken meat products. For the commercial purposes, further studies need to be carried out.

  12. Socially-marketed rapid diagnostic tests and ACT in the private sector: ten years of experience in Cambodia

    Directory of Open Access Journals (Sweden)

    Allen Henrietta

    2011-08-01

    Full Text Available Abstract Whilst some populations have recently experienced dramatic declines in malaria, the majority of those most at risk of Plasmodium falciparum malaria still lack access to effective treatment with artemisinin combination therapy (ACT and others are already facing parasites resistant to artemisinins. In this context, there is a crucial need to improve both access to and targeting of ACT through greater availability of good quality ACT and parasitological diagnosis. This is an issue of increasing urgency notably in the private commercial sector, which, in many countries, plays an important role in the provision of malaria treatment. The Affordable Medicines Facility for malaria (AMFm is a recent initiative that aims to increase the provision of affordable ACT in public, private and NGO sectors through a manufacturer-level subsidy. However, to date, there is little documented experience in the programmatic implementation of subsidized ACT in the private sector. Cambodia is in the unique position of having more than 10 years of experience not only in implementing subsidized ACT, but also rapid diagnostic tests (RDT as part of a nationwide social marketing programme. The programme includes behaviour change communication and the training of private providers as well as the sale and distribution of Malarine, the recommended ACT, and Malacheck, the RDT. This paper describes and evaluates this experience by drawing on the results of household and provider surveys conducted since the start of the programme. The available evidence suggests that providers' and consumers' awareness of Malarine increased rapidly, but that of Malacheck much less so. In addition, improvements in ACT and RDT availability and uptake were relatively slow, particularly in more remote areas. The lack of standardization in the survey methods and the gaps in the data highlight the importance of establishing a clear system for monitoring and evaluation for similar initiatives

  13. Rapid antimicrobial susceptibility testing of clinical isolates by digital time-lapse microscopy

    DEFF Research Database (Denmark)

    Fredborg, M; Rosenvinge, F S; Spillum, E

    2015-01-01

    (168 antimicrobial agent-organism combinations) demonstrated 3.6 % minor, no major and 1.2 % very major errors of the oCelloScope system compared to conventional susceptibility testing, as well as a rapid and correct phenotypic detection of strains with methicillin-resistant Staphylococcus aureus (MRSA......-to-result, enabling same-day targeted antimicrobial therapy, facilitating antibiotic stewardship and better patient management. A full-scale validation of the oCelloScope system including more isolates is necessary to assess the impact of using it for AST....

  14. Risk effectiveness evaluation of surveillance testing

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    To address the concerns about nuclear power plant surveillance tests, i.e., their adverse safety impact due to negative effects and too burdensome requirements, it is necessary to evaluate the safety significance or risk effectiveness of such tests explicitly considering both negative and positive effects. This paper defines the negative effects of surveillance testing from a risk perspective, and then presents a methodology to quantify the negative risk impact, i.e., the risk penalty or risk increase caused by the test. The method focuses on two important kinds of negative effects, namely, test-caused transients and test-caused equipment degradations. The concepts and quantitative methods for the risk evaluation can be used in the decision-making process to establish the safety significance of the tests and to screen the plant-specific surveillance test requirements. 6 refs., 2 figs., 2 tabs

  15. Evaluation of two commercial, rapid, ELISA kits testing or scrapie in retro-pharyngeal lymph nodes in sheep

    NARCIS (Netherlands)

    Kittelberger, R.; McIntuyre, L.; Watts, S.; MacDiarmid, S.; Hannah, M.J.; Jenner, J.; Bueno, R.; Swainsbury, R.; Langeveld, J.P.M.; Keulen, van L.J.M.; Zijderveld, van F.G.; Wemheuer, W.M.; Richt, J.A.; Sorenson, S.J.; Pigott, C.J.; O'Keefe, J.S.

    2014-01-01

    AIMS: To estimate the number of cases of scrapie that would occur in sheep of different prion protein (PrP) genotypes if scrapie was to become established in New Zealand, and to compare the performance of two commercially available, rapid ELISA kits using ovine retro-pharyngeal lymph nodes (RLN)

  16. Oral rapid test: an alternative to traditional HIV screening in Chile

    Directory of Open Access Journals (Sweden)

    Lisette Paola Irarrazábal

    2013-06-01

    Full Text Available OBJECTIVE: To compare the sensitivity and specificity of an Oral Rapid Test (ORT to that of the Enzyme-Linked Immunosorbent Assay (ELISA for HIV testing in Santiago, Chile; to track the number of study participants returning for ELISA testing results; and to analyze the participants' perceptions of the ORT compared to the ELISA. METHODS: A total of 497 people were recruited in Santiago, Chile: 153 had previously tested positive for HIV, and 344 were of unknown status. Participants were tested for HIV using both the ELISA and the ORT to examine and compare specificity and sensitivity. Qualitative data were collected from 22 participants to compare perceptions of the testing experience with ORT versus ELISA. RESULTS: The ELISA reported 184 (37% of the 497 participants as being "positive" for HIV antibodies; the ORT showed 181 (36.4% as being "reactive" for HIV. The ORT showed a sensitivity of 98.4% (95.7%-99.9%, 95% Confidence Interval and specificity of 100%. The Kappa test produced K = 0.983 (P < 0.0001. Of the 344 participants whose HIV status was unknown at the start of the study, 55 failed to return for their ELISA results. Participants positively perceived ORT as having reduced both waiting time and anxiety over obtaining their test results. ORT oral swabbing appeared more practical and less invasive than drawing blood for the ELISA. CONCLUSIONS: The ORT and ELISA were statistically equal in specificity and sensitivity. ORT provides quicker results, potentially ensuring that more people receive them, and does not require handling of or exposure to potentially hazardous blood products. Trial number: ClinicalTrials.gov identifier: NCT01733927.

  17. Evaluation of a rapid immunochromatographic dipstick test for detection of antibodies to Trypanosoma cruzi in dogs experimentally infected with isolates obtained from opossums (Didelphis virginiana), armadillos (Dasypus novemcinctus), and dogs (Canis familiaris) from the United States.

    Science.gov (United States)

    Rosypal, Alexa C; Hill, Roderick; Lewis, Samantha; Barr, Stephen C; Valadas, Samantha; Gennari, Solange Maria; Lindsay, David S

    2011-02-01

    Dogs are reservoir hosts for Trypanosoma cruzi , the causative agent of American trypanosomiasis. A rapid immunochromatographic dipstick test (ICT) is available commercially for canine serological testing. The ICT was developed with the use of sera from South American dogs, but it is not routinely used in the United States. We evaluated the utility of the ICT in detecting anti-T. cruzi antibodies in dogs from the United States. Dogs (N  =  64) were experimentally infected with United States' isolates of T. cruzi from an opossum (Didelphis virginiana), an armadillo (Dasypus novemcinctus), and a domestic dog (Canis familiaris), and were tested after experimental infection. Sera from uninfected United States dogs (n  =  79; hemaculture negative) were used as negative controls. In a blind study, sera were tested by the ICT and compared to the indirect immunofluorescent antibody test with the use of Brazil-strain epimastigotes as antigen. The sensitivity of the ICT was 91% and the specificity was 98% in dogs experimentally infected with United States isolates. Our study indicates that the ICT could be a useful screening tool for serological surveillance of canine T. cruzi exposure in the United States.

  18. Dual rapid lateral flow immunoassay fingerstick wholeblood testing for syphilis and HIV infections is acceptable and accurate, Port-au-Prince, Haiti.

    Science.gov (United States)

    Bristow, Claire C; Severe, Linda; Pape, Jean William; Javanbakht, Marjan; Lee, Sung-Jae; Comulada, Warren Scott; Klausner, Jeffrey D

    2016-06-18

    Dual rapid tests for HIV and syphilis infections allow for detection of HIV infection and syphilis at the point-of-care. Those tests have been evaluated in laboratory settings and show excellent performance but have not been evaluated in the field. We evaluated the field performance of the SD BIOLINE HIV/Syphilis Duo test in Port-au-Prince, Haiti using whole blood fingerprick specimens. GHESKIO (Haitian Study Group for Kaposi's Sarcoma and Opportunistic Infections) clinic attendees 18 years of age or older were invited to participate. Venipuncture blood specimens were used for reference testing with standard commercially available tests for HIV and syphilis in Haiti. The sensitivity and specificity of the Duo test compared to the reference standard were calculated. The exact binomial method was used to determine 95 % confidence intervals (CI). Of 298 study participants, 237 (79.5 %) were female, of which 49 (20.7 %) were pregnant. For the HIV test component, the sensitivity and specificity were 99.2 % (95 % CI: 95.8 %, 100 %) and 97.0 % (95 % CI: 93.2 %, 99.0 %), respectively; and for the syphilis component were 96.5 % (95 % CI: 91.2 %, 99.0 %) and 90.8 % (95 % CI: 85.7 %, 94.6 %), respectively. In pregnant women, the sensitivity and specificity of the HIV test component were 93.3 % (95 % CI: 68.0 %, 99.8 %) and 94.1 % (95 % CI: 80.3 %, 99.3 %), respectively; and for the syphilis component were 100 % (95 % CI:81.5 %, 100 %) and 96.8 % (95 % CI:83.3 %, 99.9 %), respectively. The Standard Diagnostics BIOLINE HIV/Syphilis Duo dual test performed well in a field setting in Haiti and should be considered for wider use.

  19. Rapid susceptibility testing of Mycobacterium tuberculosis by bioluminescence assay of mycobacterial ATP

    International Nuclear Information System (INIS)

    Nilsson, L.E.; Hoffner, S.E.; Ansehn, S.

    1988-01-01

    Mycobacterial growth was monitored by bioluminescence assay of mycobacterial ATP. Cultures of Mycobacterium tuberculosis H37Rv and of 25 clinical isolates of the same species were exposed to serial dilutions of ethambutol, isoniazid, rifampin, and streptomycin. A suppression of ATP, indicating growth inhibition, occurred for susceptible but not resistant strains within 5 to 7 days of incubation. Breakpoint concentrations between susceptibility and resistance were determined by comparing these results with those obtained by reference techniques. Full agreement was found in 99% of the assays with the resistance ratio method on Lowenstein-Jensen medium, and 98% of the assays were in full agreement with the radiometric system (BACTEC). A main advantage of the bioluminescence method is its rapidity, with results available as fast as with the radiometric system but at a lower cost and without the need for radioactive culture medium. The method provides kinetic data concerning drug effects within available in vivo drug concentrations and has great potential for both rapid routine susceptibility testing and research applications in studies of drug effects on mycobacteria

  20. Evaluation of ViroCyt® Virus Counter for Rapid Filovirus Quantitation

    Directory of Open Access Journals (Sweden)

    Cynthia A. Rossi

    2015-03-01

    Full Text Available Development and evaluation of medical countermeasures for diagnostics, vaccines, and therapeutics requires production of standardized, reproducible, and well characterized virus preparations. For filoviruses this includes plaque assay for quantitation of infectious virus, transmission electron microscopy (TEM for morphology and quantitation of virus particles, and real-time reverse transcription PCR for quantitation of viral RNA (qRT-PCR. The ViroCyt® Virus Counter (VC 2100 (ViroCyt, Boulder, CO, USA is a flow-based instrument capable of quantifying virus particles in solution. Using a proprietary combination of fluorescent dyes that stain both nucleic acid and protein in a single 30 min step, rapid, reproducible, and cost-effective quantification of filovirus particles was demonstrated. Using a seed stock of Ebola virus variant Kikwit, the linear range of the instrument was determined to be 2.8E+06 to 1.0E+09 virus particles per mL with coefficient of variation ranging from 9.4% to 31.5% for samples tested in triplicate. VC particle counts for various filovirus stocks were within one log of TEM particle counts. A linear relationship was established between the plaque assay, qRT-PCR, and the VC. VC results significantly correlated with both plaque assay and qRT-PCR. These results demonstrated that the VC is an easy, fast, and consistent method to quantify filoviruses in stock preparations.

  1. Evaluation of ViroCyt® Virus Counter for Rapid Filovirus Quantitation

    Directory of Open Access Journals (Sweden)

    Cynthia A. Rossi

    2015-02-01

    Full Text Available Development and evaluation of medical countermeasures for diagnostics, vaccines, and therapeutics requires production of standardized, reproducible, and well characterized virus preparations. For filoviruses this includes plaque assay for quantitation of infectious virus, transmission electron microscopy (TEM for morphology and quantitation of virus particles, and real-time reverse transcription PCR for quantitation of viral RNA (qRT-PCR. The ViroCyt® Virus Counter (VC 2100 (ViroCyt, Boulder, CO, USA is a flow-based instrument capable of quantifying virus particles in solution. Using a proprietary combination of fluorescent dyes that stain both nucleic acid and protein in a single 30 min step, rapid, reproducible, and cost-effective quantification of filovirus particles was demonstrated. Using a seed stock of Ebola virus variant Kikwit, the linear range of the instrument was determined to be 2.8E+06 to 1.0E+09 virus particles per mL with coefficient of variation ranging from 9.4% to 31.5% for samples tested in triplicate. VC particle counts for various filovirus stocks were within one log of TEM particle counts. A linear relationship was established between the plaque assay, qRT-PCR, and the VC. VC results significantly correlated with both plaque assay and qRT-PCR. These results demonstrated that the VC is an easy, fast, and consistent method to quantify filoviruses in stock preparations.

  2. Rapid diagnosis of equine influenza by highly sensitive silver amplification immunochromatography system.

    Science.gov (United States)

    Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Fu, Tao Qi Huang; Fernandez, Charlene Judith; Gildea, Sarah; Cullinane, Ann

    2017-06-16

    Equine influenza (EI) is a respiratory disease caused by equine influenza A virus (EIV, H3N8) infection. Rapid diagnosis is essential to limit the disease spread. We previously reported that some rapid antigen detection (RAD) tests are fit for diagnosing EI although their sensitivity is not optimal. Here, we evaluated the performance of the newly developed RAD test using silver amplification immunochromatography (Quick Chaser Auto Flu A, B: QCA) to diagnose EI. The detection limits of QCA for EIVs were five-fold lower than the conventional RAD tests. The duration of virus antigen detection in the infected horses was longer than the conventional RAD tests. We conclude that QCA could be a valuable diagnostic method for EI.

  3. A kinematic analysis of the rapid step test in balance-impaired and unimpaired older women.

    Science.gov (United States)

    Schulz, Brian W; Ashton-Miller, James A; Alexander, Neil B

    2007-04-01

    Little is known about the kinematic and kinetic determinants that might explain age and balance-impairment alterations in the results of volitional stepping performance tests. Maximal unipedal stance time (UST) was used to distinguish "balance-impaired" old (BI, UST30s, N=12, mean age=71 years) before they and healthy young females (Y, UST>30s, N=13, mean age=23 years) performed the rapid step test (RST). The RST evaluates the time required to take volitional front, side, and back steps of at least 80% maximum step length in response to verbal commands. Kinematic and kinetic data were recorded during the RST. The results indicate that the initiation phase of the step was the major source of age- and balance impairment-related delays. The delays in BI were primarily caused by increased postural adjustments prior to step initiation, as measured by center-of-pressure (COP) path length (p<0.003). The Step landing phase showed similar, but non-significant, temporal trends. Step length and peak center-of-mass (COM) deceleration during the Step-Out landing decreased in O by 18% (p=0.0002) and 24% (p=0.001), respectively, and a further 12% (p=0.04) and 18% (p=0.08) in BI. We conclude that the delay in BI step initiation was due to the increase in their postural adjustments prior to step initiation.

  4. Detection of malaria parasites by microscopy and rapid diagnostic ...

    African Journals Online (AJOL)

    The effectiveness of Rapid Diagnostic Test Kit (RDT) was compared with microscopy for the evaluation of malaria infection in children and pregnant women attending two selected health facilities in Lagos State, south-western, Nigeria. A total of 482 patients comprising 252 pregnant women (mean age: 26.86±4.46 years) ...

  5. Testing of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Bobbe, J.G.

    1995-01-01

    In the evaluation of the safety of radioactive material transportation it is important to consider the response of Type B packages to environments more severe than that prescribed by the hypothetical accident sequence in Title 10 Part 71 of the Code of Federal Regulations (NRC 1995). The impact event in this sequence is a 9-meter drop onto an essentially unyielding target, resulting in an impact velocity of 13.4 m/s. The behavior of 9 packages when subjected to impacts more severe than this is not well known. It is the purpose of this program to evaluate the structural response of a test package to these environments. Several types of structural response are considered. Of primary importance is the behavior of the package containment boundary, including the bolted closure and 0-rings. Other areas of concern are loss of shielding capability due to lead slump and the deceleration loading of package contents, that may cause damage to them. This type of information is essential for conducting accurate risk assessments on the transportation of radioactive materials. Currently very conservative estimates of the loss of package protection are used in these assessments. This paper will summarize the results of a regulatory impact test and three extra-regulatory impact tests on a sample package

  6. ANCA-GBM dot-blot : Evaluation of an assay in the differential diagnosis of patients presenting with rapidly progressive glomerulonephritis

    NARCIS (Netherlands)

    Rutgers, Abraham; Damoiseaux, Jan; Roozendaal, Caroline; Limburg, Pieter C; Stegeman, Coen A; Tervaert, Jan Willem Cohen

    Rapidly progressive glomerulonephritis (RPGN) is characterized by rapid and progressive loss of renal function and the presence of crescentic glomerulonephritis (CGN). Early diagnosis and appropriate treatment is mandatory to prevent death and/or renal failure. We have evaluated an ANCA-GBM dot-blot

  7. Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review.

    Science.gov (United States)

    Whiting, Penny; Westwood, Marie; Watt, Ian; Cooper, Julie; Kleijnen, Jos

    2005-04-05

    Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation.

  8. Rapid molecular diagnostics for multi-drug resistant tuberculosis in India.

    Science.gov (United States)

    Ramachandran, Rajeswari; Muniyandi, M

    2018-03-01

    Rapid molecular diagnostic methods help in the detection of TB and Rifampicin resistance. These methods detect TB early, are accurate and play a crucial role in reducing the burden of drug resistant tuberculosis. Areas covered: This review analyses rapid molecular diagnostic tools used in the diagnosis of MDR-TB in India, such as the Line Probe Assay and GeneXpert. We have discussed the burden of MDR-TB and the impact of recent diagnostic tools on case detection and treatment outcomes. This review also discusses the costs involved in establishing these new techniques in India. Expert commentary: Molecular methods have considerable advantages for the programmatic management of drug resistant TB. These include speed, standardization of testing, potentially high throughput and reduced laboratory biosafety requirements. There is a desperate need for India to adopt modern, rapid, molecular tools with point-of-care tests being currently evaluated. New molecular diagnostic tests appear to be cost effective and also help in detecting missing cases. There is enough evidence to support the scaling up of these new tools in India.

  9. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Sprogøe-Jakobsen, U; Pedersen, C M

    1998-01-01

    The vast majority of infusion pumps used for rapid transfusion of large amounts of blood have never been properly examined regarding their influence on the quality of the red blood cells (RBCs) infused. In this study, we evaluated the effect of two different infusion pumps on the degree of RBC...

  10. Waste feed delivery test and evaluation plan

    Energy Technology Data Exchange (ETDEWEB)

    O' TOOLE, S.M.

    1999-09-30

    This plan documents the Waste Feed Delivery Program test and evaluation planning and implementation approach. The purpose of this document is to define and communicate the Waste Feed Delivery Program Test and Evaluation scope, objectives, planning and implementation approach.

  11. Waste feed delivery test and evaluation plan

    International Nuclear Information System (INIS)

    O'TOOLE, S.M.

    1999-01-01

    This plan documents the Waste Feed Delivery Program test and evaluation planning and implementation approach. The purpose of this document is to define and communicate the Waste Feed Delivery Program Test and Evaluation scope, objectives, planning and implementation approach

  12. Direct nitrate reductase assay versus microscopic observation drug susceptibility test for rapid detection of MDR-TB in Uganda.

    Directory of Open Access Journals (Sweden)

    Freddie Bwanga

    Full Text Available The most common method for detection of drug resistant (DR TB in resource-limited settings (RLSs is indirect susceptibility testing on Lowenstein-Jensen medium (LJ which is very time consuming with results available only after 2-3 months. Effective therapy of DR TB is therefore markedly delayed and patients can transmit resistant strains. Rapid and accurate tests suitable for RLSs in the diagnosis of DR TB are thus highly needed. In this study we compared two direct techniques--Nitrate Reductase Assay (NRA and Microscopic Observation Drug Susceptibility (MODS for rapid detection of MDR-TB in a high burden RLS. The sensitivity, specificity, and proportion of interpretable results were studied. Smear positive sputum was collected from 245 consecutive re-treatment TB patients attending a TB clinic in Kampala, Uganda. Samples were processed at the national reference laboratory and tested for susceptibility to rifampicin and isoniazid with direct NRA, direct MODS and the indirect LJ proportion method as reference. A total of 229 specimens were confirmed as M. tuberculosis, of these interpretable results were obtained in 217 (95% with either the NRA or MODS. Sensitivity, specificity and kappa agreement for MDR-TB diagnosis was 97%, 98% and 0.93 with the NRA; and 87%, 95% and 0.78 with the MODS, respectively. The median time to results was 10, 7 and 64 days with NRA, MODS and the reference technique, respectively. The cost of laboratory supplies per sample was low, around 5 USD, for the rapid tests. The direct NRA and MODS offered rapid detection of resistance almost eight weeks earlier than with the reference method. In the study settings, the direct NRA was highly sensitive and specific. We consider it to have a strong potential for timely detection of MDR-TB in RLS.

  13. Rapid BRAF mutation tests in patients with advanced melanoma : Comparison of immunohistochemistry, Droplet Digital PCR, and the Idylla Mutation Platform

    NARCIS (Netherlands)

    Bisschop, Cornelis; Ter Elst, Arja; Bosman, Lisette J; Platteel, Inge; Jalving, Mathilde; van den Berg, Anke; Diepstra, Arjan; van Hemel, Bettien; Diercks, Gilles F H; Hospers, Geke A P; Schuuring, Ed

    BRAF mutational testing has become a common practice in the diagnostic process of patients with advanced melanoma. Although time-consuming, DNA sequencing techniques are the current gold standard for mutational testing. However, in certain clinical situations, a rapid test result is required. In

  14. Cross-lingual tagger evaluation without test data

    DEFF Research Database (Denmark)

    Agic, Zeljko; Plank, Barbara; Søgaard, Anders

    2017-01-01

    We address the challenge of cross-lingual POS tagger evaluation in absence of manually annotated test data. We put forth and evaluate two dictionary-based metrics. On the tasks of accuracy prediction and system ranking, we reveal that these metrics are reliable enough to approximate test set-base......-based evaluation, and at the same time lean enough to support assessment for truly low-resource languages....

  15. Role of diagnostic tests in esophageal evaluation

    International Nuclear Information System (INIS)

    Silverstein, B.D.; Pope, C.E. II

    1980-01-01

    In the evaluation of esophageal disease, the appropriate question must be asked before the correct tests can be selected. Reflux can be demonstrated by radiologic methods, pH testing or radioisotopic techniques. Esophageal mucosal damage is best evaluated by x-ray, endoscopy, or biopsy. Chest pain is demonstrated by acid infusion or by manometry. Two algorithms are presented for the evaluation of chest pain and reflux symptoms

  16. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  17. Evaluation of an Immunochromatographic Assay for Rapid Detection of Penicillin-Binding Protein 2a in Human and Animal Staphylococcus intermedius Group, Staphylococcus lugdunensis, and Staphylococcus schleiferi Clinical Isolates.

    Science.gov (United States)

    Arnold, A R; Burnham, C-A D; Ford, B A; Lawhon, S D; McAllister, S K; Lonsway, D; Albrecht, V; Jerris, R C; Rasheed, J K; Limbago, B; Burd, E M; Westblade, L F

    2016-03-01

    The performance of a rapid penicillin-binding protein 2a (PBP2a) detection assay, the Alere PBP2a culture colony test, was evaluated for identification of PBP2a-mediated beta-lactam resistance in human and animal clinical isolates of Staphylococcus intermedius group, Staphylococcus lugdunensis, and Staphylococcus schleiferi. The assay was sensitive and specific, with all PBP2a-negative and PBP2a-positive strains testing negative and positive, respectively. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  18. Performance of an Optimized Paper-Based Test for Rapid Visual Measurement of Alanine Aminotransferase (ALT in Fingerstick and Venipuncture Samples.

    Directory of Open Access Journals (Sweden)

    Sidhartha Jain

    Full Text Available A paper-based, multiplexed, microfluidic assay has been developed to visually measure alanine aminotransferase (ALT in a fingerstick sample, generating rapid, semi-quantitative results. Prior studies indicated a need for improved accuracy; the device was subsequently optimized using an FDA-approved automated platform (Abaxis Piccolo Xpress as a comparator. Here, we evaluated the performance of the optimized paper test for measurement of ALT in fingerstick blood and serum, as compared to Abaxis and Roche/Hitachi platforms. To evaluate feasibility of remote results interpretation, we also compared reading cell phone camera images of completed tests to reading the device in real time.96 ambulatory patients with varied baseline ALT concentration underwent fingerstick testing using the paper device; cell phone images of completed devices were taken and texted to a blinded off-site reader. Venipuncture serum was obtained from 93/96 participants for routine clinical testing (Roche/Hitachi; subsequently, 88/93 serum samples were captured and applied to paper and Abaxis platforms. Paper test and reference standard results were compared by Bland-Altman analysis.For serum, there was excellent agreement between paper test and Abaxis results, with negligible bias (+4.5 U/L. Abaxis results were systematically 8.6% lower than Roche/Hitachi results. ALT values in fingerstick samples tested on paper were systematically lower than values in paired serum tested on paper (bias -23.6 U/L or Abaxis (bias -18.4 U/L; a correction factor was developed for the paper device to match fingerstick blood to serum. Visual reads of cell phone images closely matched reads made in real time (bias +5.5 U/L.The paper ALT test is highly accurate for serum testing, matching the reference method against which it was optimized better than the reference methods matched each other. A systematic difference exists between ALT values in fingerstick and paired serum samples, and can be

  19. A cross-sectional survey of attitudes to HIV risk and rapid HIV testing among clients of sex workers in Switzerland.

    Science.gov (United States)

    Darling, Katharine E A; Diserens, Esther-Amélie; N'garambe, Chantal; Ansermet-Pagot, Anne; Masserey, Eric; Cavassini, Matthias; Bodenmann, Patrick

    2012-10-01

    To assess attitudes to HIV risk and acceptability of rapid HIV testing among clients of street-based female sex workers (FSW) in Lausanne, Switzerland, where HIV prevalence in the general population is 0.4%. The authors conducted a cross-sectional study in the red light district of Lausanne for five nights in September of 2008, 2009 and 2010. Clients of FSW were invited to complete a questionnaire in the street assessing demographic characteristics, attitudes to HIV risk and HIV testing history. All clients interviewed were then offered anonymous finger stick rapid HIV testing in a van parked on-site. The authors interviewed 112, 127 and 79 clients in 2008, 2009 and 2010, respectively. All were men, average age 32-37 years old; 40-60% were in a stable relationship. History of unprotected sex was higher with non-commercial partners (33-50%) than with FSW (6-11%); 29-46% of clients had never undergone an HIV test. Anonymous rapid HIV testing was accepted by 45-50% of clients. Out of 109 HIV tests conducted during the three study periods, none was reactive. On-site HIV counselling and testing is acceptable among clients of FSW in this urban setting. These individuals represent an unquantified population, a proportion of which has an incomplete understanding of HIV risk in the face of high-risk behaviour, with implications for potential onward transmission to non-commercial sexual partners.

  20. Clinical Evaluation of 2 Point-of-Care Lateral Flow Tests for the Diagnosis of Syphilis.

    Science.gov (United States)

    Nakku-Joloba, Edith; Kiragga, Agnes; Mbazira, Joshua Kimeze; Kambugu, Fred; Jett-Goheen, Mary; Ratanshi, Rosalind Parkes; Gaydos, Charlotte; Manabe, Yukari C

    2016-10-01

    A diagnostic performance study comparing the only Food and Drug Administration-approved, point-of-care (POC) treponemal test (Syphilis Health Check) and the World Health Organization pre-qualified SD Bioline POC treponemal test against a treponemal hemagglutination test (TPHA) and a sequential algorithm of nontreponemal rapid plasma reagin and TPHA found both POC tests had >85% sensitivity compared with the TPHA and >85% sensitivity and >95% specificity compared with the rapid plasma reagin and TPHA standards.

  1. Rapidly Progressive Quadriplegia and Encephalopathy.

    Science.gov (United States)

    Wynn, DonRaphael; McCorquodale, Donald; Peters, Angela; Juster-Switlyk, Kelsey; Smith, Gordon; Ansari, Safdar

    2016-11-01

    A woman aged 77 years was transferred to our neurocritical care unit for evaluation and treatment of rapidly progressive motor weakness and encephalopathy. Examination revealed an ability to follow simple commands only and abnormal movements, including myoclonus, tongue and orofacial dyskinesias, and opsoclonus. Imaging study findings were initially unremarkable, but when repeated, they demonstrated enhancement of the cauda equina nerve roots, trigeminal nerve, and pachymeninges. Cerebrospinal fluid examination revealed mildly elevated white blood cell count and protein levels. Serial electrodiagnostic testing demonstrated a rapidly progressive diffuse sensory motor axonopathy, and electroencephalogram findings progressed from generalized slowing to bilateral periodic lateralized epileptiform discharges. Critical details of her recent history prompted a diagnostic biopsy. Over time, the patient became completely unresponsive with no further abnormal movements and ultimately died. The differential diagnosis, pathological findings, and diagnosis are discussed with a brief review of a well-known yet rare diagnosis.

  2. SMS messages increase adherence to rapid diagnostic test results among malaria patients: results from a pilot study in Nigeria.

    Science.gov (United States)

    Modrek, Sepideh; Schatzkin, Eric; De La Cruz, Anna; Isiguzo, Chinwoke; Nwokolo, Ernest; Anyanti, Jennifer; Ujuju, Chinazo; Montagu, Dominic; Liu, Jenny

    2014-02-25

    The World Health Organization now recommends parasitological confirmation for malaria case management. Rapid diagnostic tests (RDTs) for malaria are an accurate and simple diagnostic to confirm parasite presence in blood. However, where they have been deployed, adherence to RDT results has been poor, especially when the test result is negative. Few studies have examined adherence to RDTs distributed or purchased through the private sector. The Rapid Examination of Malaria and Evaluation of Diagnostic Information (REMEDI) study assessed the acceptability of and adherence to RDT results for patients seeking care from private sector drug retailers in two cities in Oyo State in south-west Nigeria. In total, 465 adult participants were enrolled upon exit from a participating drug shop having purchased anti-malaria drugs for themselves. Participants were given a free RDT and the appropriate treatment advice based on their RDT result. Short Message Service (SMS) text messages reiterating the treatment advice were sent to a randomly selected half of the participants one day after being tested. Participants were contacted via phone four days after the RDT was conducted to assess adherence to the RDT information and treatment advice. Adherence to RDT results was 14.3 percentage points (P-val <0.001) higher in the treatment group who were sent the SMS. The higher adherence in the treatment group was robust to several specification tests and the estimated difference in adherence ranged from 9.7 to 16.1 percentage points. Further, the higher adherence to the treatment advice was specific to the treatment advice for anti-malarial drugs and not other drugs purchased to treat malaria symptoms in the RDT-negative participants who bought both anti-malarial and symptom drugs. There was no difference in adherence for the RDT-positive participants who were sent the SMS. SMS text messages substantially increased adherence to RDT results for patients seeking care for malaria from

  3. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  4. The use of an automated flight test management system in the development of a rapid-prototyping flight research facility

    Science.gov (United States)

    Duke, Eugene L.; Hewett, Marle D.; Brumbaugh, Randal W.; Tartt, David M.; Antoniewicz, Robert F.; Agarwal, Arvind K.

    1988-01-01

    An automated flight test management system (ATMS) and its use to develop a rapid-prototyping flight research facility for artificial intelligence (AI) based flight systems concepts are described. The ATMS provides a flight test engineer with a set of tools that assist in flight planning and simulation. This system will be capable of controlling an aircraft during the flight test by performing closed-loop guidance functions, range management, and maneuver-quality monitoring. The rapid-prototyping flight research facility is being developed at the Dryden Flight Research Facility of the NASA Ames Research Center (Ames-Dryden) to provide early flight assessment of emerging AI technology. The facility is being developed as one element of the aircraft automation program which focuses on the qualification and validation of embedded real-time AI-based systems.

  5. Increased corrosion resistance of the AZ80 magnesium alloy by rapid solidification.

    Science.gov (United States)

    Aghion, E; Jan, L; Meshi, L; Goldman, J

    2015-11-01

    Magnesium (Mg) and Mg-alloys are being considered as implantable biometals. Despite their excellent biocompatibility and good mechanical properties, their rapid corrosion is a major impediment precluding their widespread acceptance as implantable biomaterials. Here, we investigate the potential for rapid solidification to increase the corrosion resistance of Mg alloys. To this end, the effect of rapid solidification on the environmental and stress corrosion behavior of the AZ80 Mg alloy vs. its conventionally cast counterpart was evaluated in simulated physiological electrolytes. The microstructural characteristics were examined by optical microscopy, SEM, TEM, and X-ray diffraction analysis. The corrosion behavior was evaluated by immersion, salt spraying, and potentiodynamic polarization. Stress corrosion resistance was assessed by Slow Strain Rate Testing. The results indicate that the corrosion resistance of rapidly solidified ribbons is significantly improved relative to the conventional cast alloy due to the increased Al content dissolved in the α-Mg matrix and the correspondingly reduced presence of the β-phase (Mg17 Al12 ). Unfortunately, extrusion consolidated solidified ribbons exhibited a substantial reduction in the environmental performance and stress corrosion resistance. This was mainly attributed to the detrimental effect of the extrusion process, which enriched the iron impurities and increased the internal stresses by imposing a higher dislocation density. In terms of immersion tests, the average corrosion rate of the rapidly solidified ribbons was <0.4 mm/year compared with ∼2 mm/year for the conventionally cast alloy and 26 mm/year for the rapidly solidified extruded ribbons. © 2014 Wiley Periodicals, Inc.

  6. An adaptive toolkit for image quality evaluation in system performance test of digital breast tomosynthesis

    Science.gov (United States)

    Zhang, Guozhi; Petrov, Dimitar; Marshall, Nicholas; Bosmans, Hilde

    2017-03-01

    Digital breast tomosynthesis (DBT) is a relatively new diagnostic imaging modality for women. Currently, various models of DBT systems are available on the market and the number of installations is rapidly increasing. EUREF, the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services, has proposed a preliminary Guideline - protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, with an ultimate aim of providing limiting values guaranteeing proper performance for different applications of DBT. In this work, we introduce an adaptive toolkit developed in accordance with this guideline to facilitate the process of image quality evaluation in DBT performance test. This toolkit implements robust algorithms to quantify various technical parameters of DBT images and provides a convenient user interface in practice. Each test is built into a separate module with configurations set corresponding to the European guideline, which can be easily adapted to different settings and extended with additional tests. This toolkit largely improves the efficiency for image quality evaluation of DBT. It is also going to evolve with the development of protocols in quality control of DBT systems.

  7. Rapid Detection of the Chlamydiaceae and Other Families in the Order Chlamydiales: Three PCR Tests

    Science.gov (United States)

    Everett, Karin D. E.; Hornung, Linda J.; Andersen, Arthur A.

    1999-01-01

    Few identification methods will rapidly or specifically detect all bacteria in the order Chlamydiales, family Chlamydiaceae. In this study, three PCR tests based on sequence data from over 48 chlamydial strains were developed for identification of these bacteria. Two tests exclusively recognized the Chlamydiaceae: a multiplex test targeting the ompA gene and the rRNA intergenic spacer and a TaqMan test targeting the 23S ribosomal DNA. The multiplex test was able to detect as few as 200 inclusion-forming units (IFU), while the TaqMan test could detect 2 IFU. The amplicons produced in these tests ranged from 132 to 320 bp in length. The third test, targeting the 23S rRNA gene, produced a 600-bp amplicon from strains belonging to several families in the order Chlamydiales. Direct sequence analysis of this amplicon has facilitated the identification of new chlamydial strains. These three tests permit ready identification of chlamydiae for diagnostic and epidemiologic study. The specificity of these tests indicates that they might also be used to identify chlamydiae without culture or isolation. PMID:9986815

  8. Pre-test evaluation of LLTR Series II Test A-6

    International Nuclear Information System (INIS)

    Knittle, D.

    1980-11-01

    Purpose of this report is to present pre-test predictions of pressure histories for the A6 test to be conducted in the Large Leak Test Facility (LLTF) at the Energy Technology Engineering Center. A6 is part of a test program being conducted to evaluate the effects of leaks produced by a double-ended guillotine rupture of a single tube. A6 will provide data on the CRBR prototypical double rupture disc performance

  9. Integrated Locomotor Function Tests for Countermeasure Evaluation

    Science.gov (United States)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Landsness, E. C.; Black, F. O.

    2005-01-01

    adaptive remodeling of the full-body gaze control systems following exposure to visual-vestibular conflict. Subjects walked on a treadmill before and after a 30- minute exposure to 0.5X minifying during which self-generated sinusoidal vertical head rotations were performed while seated. Following exposure to visual-vestibular conflict subjects showed a restriction in compensatory head movements, increased knee and ankle flexion after heel-strike and a decrease in the rate of body loading during the rapid weight transfer phase after the heel strike event. Taken together, results from both studies provide evidence that the full body contributes to gaze stabilization during locomotion, and that different functional elements are responsive to changes in visual task constraints and are subject to adaptive alterations following exposure to visual-vestibular conflict. This information provides the basis for the design of a new generation of integrative tests that incorporate the evaluation of multiple neural control systems relevant to astronaut operational performance.

  10. Incidental learning during rapid information processing on the symbol-digit modalities test.

    Science.gov (United States)

    Denney, Douglas R; Hughes, Abbey J; Elliott, Jacquelyn K; Roth, Alexandra K; Lynch, Sharon G

    2015-06-01

    The Symbol--Digit Modalities Test (SDMT) is widely used to assess processing speed in MS patients. We developed a computerized version of the SDMT (c-SDMT) that scored participants' performance during subintervals over the course of the usual 90-s time period and also added an incidental learning test (c-ILT) to assess how well participants learned the symbol-digit associations while completing the c-SDMT. Patients with MS (n = 65) achieved lower scores than healthy controls (n = 38) on both the c-SDMT and c-ILT, and the scores on the two tests were correlated. However, no increase in the rate of item completion occurred for either group over the course of the c-SDMT, and the difference between groups was the same during each subinterval. Therefore, it seems implausible that controls completed more items on the c-SDMT because they were more adept at learning the symbol-digit associations as the test ensued. Instead, MS patients' poorer incidental learning performance appears to reflect the greater attentional burden that tasks requiring rapid serial processing of information impose upon them. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Test facilities for evaluating nuclear thermal propulsion systems

    International Nuclear Information System (INIS)

    Beck, D.F.; Allen, G.C.; Shipers, L.R.; Dobranich, D.; Ottinger, C.A.; Harmon, C.D.; Fan, W.C.; Todosow, M.

    1992-01-01

    Interagency panels evaluating nuclear thermal propulsion (NTP) development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and baseline performance of some of the major subsystems designed to support a proposed ground test complex for evaluating nuclear thermal propulsion fuel elements and engines being developed for the Space Nuclear Thermal Propulsion (SNTP) program. Some preliminary results of evaluating this facility for use in testing other NTP concepts are also summarized

  12. Performance of rapid diagnostic test, blood-film microscopy and PCR for the diagnosis of malaria infection among febrile children from Korogwe District, Tanzania

    DEFF Research Database (Denmark)

    Mahende, Coline; Ngasala, Billy; Lusingu, John

    2016-01-01

    with fever and/or history of fever in the previous 48 h attending outpatient clinics. Blood samples were collected for identification of Plasmodium falciparum infection using histidine-rich-protein-2 (HRP-2)-based malaria RDT, light microscopy and conventional PCR. Results: A total of 867 febrile patients......Background: Rapid diagnostic tests (RDT) and light microscopy are still recommended for diagnosis to guide the clinical management of malaria despite difficult challenges in rural settings. The performance of these tests may be affected by several factors, including malaria prevalence and intensity...... of transmission. The study evaluated the diagnostic performance of malaria RDT, light microscopy and polymerase chain reaction (PCR) in detecting malaria infections among febrile children at outpatient clinic in Korogwe District, northeastern Tanzania. Methods: The study enrolled children aged 2-59 months...

  13. An evaluation of rapid methods for monitoring vegetation characteristics of wetland bird habitat

    Science.gov (United States)

    Tavernia, Brian G.; Lyons, James E.; Loges, Brian W.; Wilson, Andrew; Collazo, Jaime A.; Runge, Michael C.

    2016-01-01

    Wetland managers benefit from monitoring data of sufficient precision and accuracy to assess wildlife habitat conditions and to evaluate and learn from past management decisions. For large-scale monitoring programs focused on waterbirds (waterfowl, wading birds, secretive marsh birds, and shorebirds), precision and accuracy of habitat measurements must be balanced with fiscal and logistic constraints. We evaluated a set of protocols for rapid, visual estimates of key waterbird habitat characteristics made from the wetland perimeter against estimates from (1) plots sampled within wetlands, and (2) cover maps made from aerial photographs. Estimated percent cover of annuals and perennials using a perimeter-based protocol fell within 10 percent of plot-based estimates, and percent cover estimates for seven vegetation height classes were within 20 % of plot-based estimates. Perimeter-based estimates of total emergent vegetation cover did not differ significantly from cover map estimates. Post-hoc analyses revealed evidence for observer effects in estimates of annual and perennial covers and vegetation height. Median time required to complete perimeter-based methods was less than 7 percent of the time needed for intensive plot-based methods. Our results show that rapid, perimeter-based assessments, which increase sample size and efficiency, provide vegetation estimates comparable to more intensive methods.

  14. Evaluation of hydrogen sulphide test for detection of fecal coliform ...

    African Journals Online (AJOL)

    GREGO

    2007-03-19

    Mar 19, 2007 ... on production of hydrogen sulphide by bacteria that are associated with fecal contamination. This rapid fields test needs no technical staff and the cost is lower than ..... Sources and Potable Water Supplies in Peru.

  15. Evaluation of the diagnostic performance and operational ...

    African Journals Online (AJOL)

    The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Methods: Four rapid ...

  16. Evaluation of a rapid LMP-based approach for calculating marginal unit emissions

    International Nuclear Information System (INIS)

    Rogers, Michelle M.; Wang, Yang; Wang, Caisheng; McElmurry, Shawn P.; Miller, Carol J.

    2013-01-01

    Graphical abstract: Display Omitted - Highlights: • Pollutant emissions estimated based on locational marginal price and eGRID data. • Stochastic model using IEEE RTS-96 system used to evaluate LMP approach. • Incorporating membership function enhanced reliability of pollutant estimate. • Error in pollutant estimate typically 2 and X and SO 2 . - Abstract: To evaluate the sustainability of systems that draw power from electrical grids there is a need to rapidly and accurately quantify pollutant emissions associated with power generation. Air emissions resulting from electricity generation vary widely among power plants based on the types of fuel consumed, the efficiency of the plant, and the type of pollution control systems in service. To address this need, methods for estimating real-time air emissions from power generation based on locational marginal prices (LMPs) have been developed. Based on LMPs the type of the marginal generating unit can be identified and pollutant emissions are estimated. While conceptually demonstrated, this LMP approach has not been rigorously tested. The purpose of this paper is to (1) improve the LMP method for predicting pollutant emissions and (2) evaluate the reliability of this technique through power system simulations. Previous LMP methods were expanded to include marginal emissions estimates using an LMP Emissions Estimation Method (LEEM). The accuracy of emission estimates was further improved by incorporating a probability distribution function that characterize generator fuel costs and a membership function (MF) capable of accounting for multiple marginal generation units. Emission estimates were compared to those predicted from power flow simulations. The improved LEEM was found to predict the marginal generation type approximately 70% of the time based on typical system conditions (e.g. loads and fuel costs) without the use of a MF. With the addition of a MF, the LEEM was found to provide emission estimates with

  17. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  18. Field Testing of Rapid Electrokinetic Nanoparticle Treatment for Corrosion Control of Steel in Concrete

    Science.gov (United States)

    Cardenas, Henry E.; Alexander, Joshua B.; Kupwade-Patil,Kunal; Calle, Luz Marina

    2009-01-01

    This work field tested the use of electrokinetics for delivery of concrete sealing nanoparticles concurrent with the extraction of chlorides. Several cylinders of concrete were batched and placed in immersion at the Kennedy Space Center Beach Corrosion Test Site. The specimens were batched with steel reinforcement and a 4.5 wt.% (weight percent) content of sodium chloride. Upon arrival at Kennedy Space Center, the specimens were placed in the saltwater immersion pool at the Beach Corrosion Test Site. Following 30 days of saltwater exposure, the specimens were subjected to rapid chloride extraction concurrent with electrokinetic nanoparticle treatment. The treatments were operated at up to eight times the typical current density in order to complete the treatment in 7 days. The findings indicated that the short-term corrosion resistance of the concrete specimens was significantly enhanced as was the strength of the concrete.

  19. Economic evaluation of laboratory testing strategies for hospital-associated Clostridium difficile infection.

    Science.gov (United States)

    Schroeder, Lee F; Robilotti, Elizabeth; Peterson, Lance R; Banaei, Niaz; Dowdy, David W

    2014-02-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and 93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI.

  20. Computer-facilitated rapid HIV testing in emergency care settings: provider and patient usability and acceptability.

    Science.gov (United States)

    Spielberg, Freya; Kurth, Ann E; Severynen, Anneleen; Hsieh, Yu-Hsiang; Moring-Parris, Daniel; Mackenzie, Sara; Rothman, Richard

    2011-06-01

    Providers in emergency care settings (ECSs) often face barriers to expanded HIV testing. We undertook formative research to understand the potential utility of a computer tool, "CARE," to facilitate rapid HIV testing in ECSs. Computer tool usability and acceptability were assessed among 35 adult patients, and provider focus groups were held, in two ECSs in Washington State and Maryland. The computer tool was usable by patients of varying computer literacy. Patients appreciated the tool's privacy and lack of judgment and their ability to reflect on HIV risks and create risk reduction plans. Staff voiced concerns regarding ECS-based HIV testing generally, including resources for follow-up of newly diagnosed people. Computer-delivered HIV testing support was acceptable and usable among low-literacy populations in two ECSs. Such tools may help circumvent some practical barriers associated with routine HIV testing in busy settings though linkages to care will still be needed.

  1. Additional patient outcomes and pathways in evaluations of testing

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; McCaffery, Kirsten

    2009-01-01

    Before medical tests are introduced into practice, they should be properly evaluated. Randomized trials and other comprehensive evaluations of tests and test strategies can best be designed based on an understanding of how tests can benefit or harm patients. Tests primarily affect patients' health

  2. [Evaluation of Prolex for the rapid identification of streptococci isolated in medical microbiology].

    Science.gov (United States)

    Loubinoux, J; Mihaila-Amrouche, L; Bouvet, A

    2004-10-01

    The need to rapidly identify streptococci responsible for acute infectious diseases has led to the development of agglutination techniques that are able to identify streptococcal group antigens (A, B, C, D, F, and G) directly from primoculture colonies on blood agar. The Prolex agglutination tests (Pro-Lab Diagnostics, Richmond Hill, Ontario, Canada), distributed in France by i2a, have been used for the determination of group antigens of 166 isolates of streptococci and enterococci previously identified in the National Reference Center for Streptococci. The results obtained with the Prolex reagents have permitted to correctly identify all pyogenic beta-hemolytic streptococci (23 Streptococcus pyogenes, 21 Streptococcus agalactiae, 33 Streptococcus dysgalactiae subsp. equisimilis including 6 group C and 27 group G, and 5 Streptococcus porcinus including 4 group B). Four differences between unexpected agglutinations (A or F) and species identifications have been obtained. These differences were observed for four non-hemolytic isolates of Streptococcus mutans, Streptococcus gordonii, Streptococcus infantarius, and Streptococcus suis. The anti-D reagent has been of value as a marker for isolates of enterococci. Thus, these results confirm the abilities of these agglutination tests for the grouping of beta-hemolytic streptococci. Moreover, the use of Prolex has the advantage to be rapid because of the non-enzymatic but chemical extraction of streptococcal antigens.

  3. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  4. An experimental evaluation of a new designed apparatus (NDA) for the rapid measurement of impaired motor function in rats.

    Science.gov (United States)

    Jarrahi, M; Sedighi Moghadam, B; Torkmandi, H

    2015-08-15

    Assessment of the ability of rat to balance by rotarod apparatus (ROTA) is frequently used as a measure of impaired motor system function. Most of these methods have some disadvantages, such as failing to sense motor coordination rather than endurance and as the sensitivity of the method is low, more animals are needed to obtain statistically significant results. We have designed and tested a new designed apparatus (NDA) to measure motor system function in rats. Our system consists of a glass box containing 4 beams which placed with 1cm distance between them, two electrical motors for rotating the beams, and a camera to record the movements of the rats. The RPM of the beams is adjustable digitally between 0 and 50 rounds per minute. We evaluated experimentally the capability of the NDA for the rapid measurement of impaired motor function in rats. Also we demonstrated that the sensitivity of the NDA increases by faster rotation speeds and may be more sensitive than ROTA for evaluating of impaired motor system function. Compared to a previous version of this task, our NDA provides a more efficient method to test rodents for studies of motor system function after impaired motor nervous system. In summary, our NDA will allow high efficient monitoring of rat motor system function and may be more sensitive than ROTA for evaluating of impaired motor system function in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle.

    Science.gov (United States)

    Karthik, K; Rathore, Rajesh; Thomas, Prasad; Arun, T R; Viswas, K N; Agarwal, R K; Manjunathachar, H V; Dhama, Kuldeep

    2014-01-01

    Brucella abortus, the major causative agent of abortion in cattle and a zoonotic pathogen, needs to be diagnosed at an early stage. Loop-mediated isothermal amplification (LAMP) test is easy to perform and also promising to be adapted at field level. To develop a LAMP assay for specific and rapid detection of B. abortus from clinical samples of cattle. LAMP primers were designed targeting BruAb2_0168 region using specific software tool and LAMP was optimized. The developed LAMP was tested for its specificity with 3 Brucella spp. and 11 other non-Brucella spp. Sensitivity of the developed LAMP was also carried out with known quantity of DNA. Cattle whole blood samples and aborted fetal stomach contents were collected and used for testing with developed LAMP assay and results were compared with polymerase chain reaction (PCR). The developed LAMP assay works at 61 °C for 60 min and the detection limit was observed to be 100-fold more than the conventional PCR that is commonly used for diagnosis of B. abortus. Clinical sensitivity and specificity of the developed LAMP assay was 100% when compared with Rose Bengal plate test and standard tube agglutination test. SYB® green dye I was used to visualize the result with naked eye. The novelty of the developed LAMP assay for specifically detecting B. abortus infection in cattle along with its inherent rapidness and high sensitivity can be employed for detecting this economically important pathogen of cattle at field level as well be exploited for screening of human infections.

  6. Immunochromatographic Strip Test for Rapid Detection of Diphtheria Toxin: Description and Multicenter Evaluation in Areas of Low and High Prevalence of Diphtheria

    Science.gov (United States)

    Engler, K. H.; Efstratiou, A.; Norn, D.; Kozlov, R. S.; Selga, I.; Glushkevich, T. G.; Tam, M.; Melnikov, V. G.; Mazurova, I. K.; Kim, V. E.; Tseneva, G. Y.; Titov, L. P.; George, R. C.

    2002-01-01

    An immunochromatographic strip (ICS) test was developed for the detection of diphtheria toxin by using an equine polyclonal antibody as the capture antibody and colloidal gold-labeled monoclonal antibodies specific for fragment A of the diphtheria toxin molecule as the detection antibody. The ICS test has been fully optimized for the detection of toxin from bacterial cultures; the limit of detection was approximately 0.5 ng of diphtheria toxin per ml within 10 min. In a comparative study with 915 pure clinical isolates of Corynebacterium spp., the results of the ICS test were in complete agreement with those of the conventional Elek test. The ICS test was also evaluated for its ability to detect toxigenicity from clinical specimens (throat swabs) in two field studies conducted within areas of the former USSR where diphtheria is epidemic. Eight hundred fifty throat swabs were examined by conventional culture and by use of directly inoculated broth cultures for the ICS test. The results showed 99% concordance (848 of 850 specimens), and the sensitivity and specificity of the ICS test were 98% (95% confidence interval, 91 to 99%) and 99% (95% confidence interval, 99 to 100%), respectively. PMID:11773096

  7. Rapid Conditioning for the Next Generation Melting System

    Energy Technology Data Exchange (ETDEWEB)

    Rue, David M. [Gas Technology Institute, Des Plaines, IL (United States)

    2015-06-17

    This report describes work on Rapid Conditioning for the Next Generation Melting System under US Department of Energy Contract DE-FC36-06GO16010. The project lead was the Gas Technology Institute (GTI). Partners included Owens Corning and Johns Manville. Cost share for this project was provided by NYSERDA (the New York State Energy Research and Development Authority), Owens Corning, Johns Manville, Owens Illinois, and the US natural gas industry through GTI’s SMP and UTD programs. The overreaching focus of this project was to study and develop rapid refining approaches for segmented glass manufacturing processes using high-intensity melters such as the submerged combustion melter. The objectives of this project were to 1) test and evaluate the most promising approaches to rapidly condition the homogeneous glass produced from the submerged combustion melter, and 2) to design a pilot-scale NGMS system for fiberglass recycle.

  8. Marihuana contact test, evaluation and development

    Science.gov (United States)

    1976-02-01

    A colorimetric swab test for detecting human contact with marihuana was evaluated. The test was found to be capable of detecting only 83% of marihuana smokers immediately after smoking and was also demonstrated to be subject to a wide range of possib...

  9. Developing and Validating a Rapid Small-Scale Column Test Procedure for GAC Selection using Reconstituted Lyophilized NOM

    Science.gov (United States)

    Cost effective design and operation of Granular Activated Carbon (GAC) facilities requires the selection of GAC that is optimal for a specific site. Rapid small-scale column tests (RSSCTs) are widely used for GAC assessment due to several advantages, including the ability to simu...

  10. Diagnostic Value of Leukocyte Esterase Test Strip Reagents for Rapid Clinical Diagnosis of Spontaneous Bacterial Peritonitis in Patients Admitted to Hospital Emergency Departments in Iran.

    Science.gov (United States)

    Hashemian, Amir Masoud; Ahmadi, Koorosh; Zamani Moghaddam, Hamid; Zakeri, Hosein; Davoodi Navakh, Seyed Akbar; Sharifi, Mohammad Davood; Bahrami, Abdollah

    2015-10-01

    Spontaneous bacterial peritonitis (SBP) is a common and important clinical problem and is life-threatening in decompensated liver disease. Ascites fluid test by leukocyte esterase test strip has been recently proposed as an effective and rapid method to diagnose SBP in patients with cirrhosis. This study aimed to evaluate sensitivity and specificity of leukocyte esterase test strip in the diagnosis of SBP. The population of this research was all patients with cirrhosis and ascites admitted to the emergency room at Imam Reza (AS) hospital, Mashhad. A written consent was taken for inclusion in the study. 50 mL ascites sample was taken from all patients for use in a urine test strip (LER) (Urine Test Strips Convergys®Urine Matrix 11). The patient's ascites samples were evaluated for cell counting. Positive dipstick test for LER in this study considered as grade 3 +. The values of WBC > 500 cell/mm(3) or PMN > 250 cell/mm(3) considered as positive result of the gold standard method for the diagnosis of SBP. In this study, 100 patients with ascites due to cirrhosis, with an average age of 38.9 ± 6.54 years were evaluated. Twenty cases had positive results, of whom 17 cases were also detected based on the standard diagnostic criteria and other three cases were healthy individuals. Thus, sensitivity, specificity, positive and negative predictive values, and accuracy of the method were 95%, 96.3%, 85%, 97.5% and 95%, respectively. The use of leukocyte esterase urine dipstick test can be a quick and easy method in early diagnosis of SBP to start the treatment until preparation of SBP-cell count results.

  11. Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III - Grid Interconnection System Evaluator

    Energy Technology Data Exchange (ETDEWEB)

    Lundstrom, B.; Shirazi, M.; Coddington, M.; Kroposki, B.

    2013-01-01

    This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

  12. Hepatitis B virus surface antigen and anti-hepatitis C virus rapid tests underestimate hepatitis prevalence among HIV-infected patients

    DEFF Research Database (Denmark)

    Hønge, Bo Langhoff; Jespersen, S; Medina, C

    2014-01-01

    . RESULTS: Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended...

  13. Rapid aneuploidy testing (knowing less) versus traditional karyotyping (knowing more) for advanced maternal age: what would be missed, who should decide?

    Science.gov (United States)

    Leung, W C; Lau, E T; Lau, W L; Tang, Rebecca; Wong, Shell Fean; Lau, T K; Tse, K T; Wong, S F; To, W K; Ng, Lucy K L; Lao, T T; Tang, Mary H Y

    2008-02-01

    The application of rapid aneuploidy testing as a stand-alone approach in prenatal diagnosis is much debated. The major criticism of this targeted approach is that it will not detect other chromosomal abnormalities that will be picked up by traditional karyotyping. This study aimed to study the nature of such chromosomal abnormalities and whether parents would choose to terminate affected pregnancies. Retrospective study on a cytogenetic database. Eight public hospitals in Hong Kong. The karyotype results of 19 517 amniotic fluid cultures performed for advanced maternal age (>or=35 years) from 1997 to 2002 were classified according to whether they were detectable by rapid aneuploidy testing. The outcomes of pregnancies with abnormal karyotypes were reviewed from patient records. In all, 333 (1.7%) amniotic fluid cultures yielded abnormal karyotypes; 175 (52.6%) of these were detected by rapid aneuploidy testing, and included trisomy 21 (n=94, 28.2%), trisomy 18 or 13 (n=21, 6.3%), and sex chromosome abnormalities (n=60, 18.0%). The other 158 (47.4%) chromosomal abnormalities were not detectable by rapid aneuploidy testing, of which 63 (18.9%) were regarded to be of potential clinical significance and 95 (28.5%) of no clinical significance. Pregnancy outcomes in 327/333 (98.2%) of these patients were retrieved. In total, 143 (42.9%) of these pregnancies were terminated: 93/94 (98.9%) for trisomy 21, 20/21 (95.2%) for trisomy 18 or 13, 19/60 (31.7%) for sex chromosome abnormalities, and 11/63 (17.5%) for other chromosomal abnormalities with potential clinical significance. There were no terminations in the 95 pregnancies in which karyotyping results were regarded to be of no clinical significance. 'Knowing less' by the rapid aneuploidy stand-alone testing could miss about half of all chromosomal abnormalities detectable by amniocentesis performed for advanced maternal age. Findings from two fifths of the latter were of potential clinical significance, and the parents

  14. Development of an in vitro Assay, based on the BioFilm Ring Test®, for Rapid Profiling of Biofilm-Growing Bacteria

    Directory of Open Access Journals (Sweden)

    Enea Gino Di Domenico

    2016-09-01

    Full Text Available Microbial biofilm represents a major virulence factor associated with chronic and recurrent infections. Pathogenic bacteria embedded in biofilms are highly resistant to environmental and chemical agents, including antibiotics and therefore difficult to eradicate. Thus, reliable tests to assess biofilm formation by bacterial strains as well as the impact of chemicals or antibiotics on biofilm formation represent desirable tools for a most effective therapeutic management and microbiological risk control. Current methods to evaluate biofilm formation are usually time-consuming, costly, and hardly applicable in the clinical setting.The aim of the present study was to develop and assess a simple and reliable in vitro procedure for the characterization of biofilm-producing bacterial strains for future clinical applications based on the BioFilm Ring Test® (BRT technology. The procedure developed for clinical testing (cBRT can provide an accurate and timely (5 hours measurement of biofilm formation for the most common pathogenic bacteria seen in clinical practice. The results gathered by the cBRT assay were in agreement with the traditional crystal violet (CV staining test, according to the kappa coefficient test (kappa = 0.623. However, the cBRT assay showed higher levels of specificity (92.2% and accuracy (88.1% as compared to CV. The results indicate that this procedure offers an easy, rapid and robust assay to test microbial biofilm and a promising tool for clinical microbiology.

  15. Economic Evaluation of Laboratory Testing Strategies for Hospital-Associated Clostridium difficile Infection

    Science.gov (United States)

    Robilotti, Elizabeth; Peterson, Lance R.; Banaei, Niaz; Dowdy, David W.

    2014-01-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and 93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI. PMID:24478478

  16. Potential Bedside Utility of the Clock-Drawing Test in Evaluating Rapid Therapeutic Response in the Natural Course of Schizophrenia: A Preliminary Study.

    Science.gov (United States)

    Ransing, Ramdas Sarjerao; Khairkar, Praveen Homdeorao; Mishra, Kshirod; Sakekar, Gajanan

    2017-01-01

    The Clock-Drawing Test (CDT) is a brief, relatively time-efficient, easy to administer at bedside, and well-proven cognitive screening test that assesses a broad range of cognitive abilities in stroke, delirium, and dementia. However, challenges of comprehensive therapeutic outcome evaluations in schizophrenia can also be potentially overcome using CDT. The authors aimed to measure the therapeutic outcome using CDT in 101 schizophrenia patients, irrespective of their diagnostic subtypes. A repeated measures analysis of variance found that improvements on CDT and the Positive and Negative Syndrome Scale were closely correlated, reflecting critical information about therapeutic response measures in schizophrenia.

  17. Has introduction of rapid drug susceptibility testing at diagnosis impacted treatment outcomes among previously treated tuberculosis patients in Gujarat, India?

    Directory of Open Access Journals (Sweden)

    Paresh Dave

    Full Text Available Revised National TB Control Programme (RNTCP in India recommends that all previously-treated TB (PT patients are offered drug susceptibility testing (DST at diagnosis, using rapid diagnostics and screened out for rifampicin resistance before being treated with standardized, eight-month, retreatment regimen. This is intended to improve the early diagnosis of rifampicin resistance and its appropriate management and improve the treatment outcomes among the rest of the patients. In this state-wide study from Gujarat, India, we assess proportion of PT patients underwent rapid DST at diagnosis and the impact of this intervention on their treatment outcomes.This is a retrospective cohort study involving review of electronic patient-records maintained routinely under RNTCP. All PT patients registered for treatment in Gujarat during January-June 2013 were included. Information on DST and treatment outcomes were extracted from 'presumptive DR-TB patient register' and TB treatment register respectively. We performed a multivariate analysis to assess if getting tested is independently associated with unfavourable outcomes (death, loss-to-follow-up, failure, transfer out.Of 5,829 PT patients, 5306(91% were tested for drug susceptibility with rapid diagnostics. Overall, 71% (4,113 TB patients were successfully treated - 72% among tested versus 60% among non-tested. Patients who did not get tested at diagnosis had a 34% higher risk of unsuccessful outcomes as compared to those who got tested (aRR - 1.34; 95% CI 1.20-1.50 after adjusting for age, sex, HIV status and type of TB. Unfavourable outcomes (particularly failure and switched to category IV were higher among INH-resistant patients (39% as compared to INH-sensitive (29%.Offering DST at diagnosis improved the treatment outcomes among PT patients. However, even among tested, treatment outcomes remained suboptimal and were related to INH resistance and high loss-to-follow-up. These need to be addressed

  18. Expediting the Analysis of Qualitative Data in Evaluation: A Procedure for the Rapid Identification of Themes from Audio Recordings (RITA)

    Science.gov (United States)

    Neal, Jennifer Watling; Neal, Zachary P.; VanDyke, Erika; Kornbluh, Mariah

    2015-01-01

    Qualitative data offer advantages to evaluators, including rich information about stakeholders' perspectives and experiences. However, qualitative data analysis is labor-intensive and slow, conflicting with evaluators' needs to provide punctual feedback to their clients. In this method note, we contribute to the literature on rapid evaluation and…

  19. Development and evaluation of a magnetic immunochromatographic test to detect Taenia solium, which causes taeniasis and neurocysticercosis in humans.

    Science.gov (United States)

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N; Dong, X Fan; Laborde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E; Garcia, Hector H; Gilman, Robert H; Tsang, Victor C W; Wilkins, Patricia P

    2010-04-01

    Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis.

  20. Development and Evaluation of a Magnetic Immunochromatographic Test To Detect Taenia solium, Which Causes Taeniasis and Neurocysticercosis in Humans▿

    Science.gov (United States)

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N.; Dong, X. Fan; LaBorde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E.; Garcia, Hector H.; Gilman, Robert H.; Tsang, Victor C. W.; Wilkins, Patricia P.

    2010-01-01

    Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis. PMID:20181766

  1. Surface resistivity test evaluation as an indicator of the chloride permeability of concrete.

    Science.gov (United States)

    2012-12-01

    Many agencies have adopted the standard tests for electrical : indication of concretes ability to resist chloride ion penetration : (AASHTO T 277 and ASTM C1202), commonly known as the rapid : chloride permeability test (RCPT), in their specificat...

  2. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  3. Evaluation of a simple and rapid dipstick assay for the diagnosis of typhoid fever in Indonesia

    NARCIS (Netherlands)

    Gasem, M. Hussein; Smits, Henk L.; Goris, Marga G. A.; Dolmans, Wil M. V.

    2002-01-01

    To support the clinical diagnosis of typhoid fever in Indonesia, where most hospitals and health centres have no facilities for culture, a rapid dipstick assay for the detection of Salmonella typhi-specific IgM antibodies was evaluated on serum samples from 127 patients clinically suspected of

  4. Evaluating rodent motor functions: Which tests to choose?

    Science.gov (United States)

    Schönfeld, Lisa-Maria; Dooley, Dearbhaile; Jahanshahi, Ali; Temel, Yasin; Hendrix, Sven

    2017-12-01

    Damage to the motor cortex induced by stroke or traumatic brain injury (TBI) can result in chronic motor deficits. For the development and improvement of therapies, animal models which possess symptoms comparable to the clinical population are used. However, the use of experimental animals raises valid ethical and methodological concerns. To decrease discomfort by experimental procedures and to increase the quality of results, non-invasive and sensitive rodent motor tests are needed. A broad variety of rodent motor tests are available to determine deficits after stroke or TBI. The current review describes and evaluates motor tests that fall into three categories: Tests to evaluate fine motor skills and grip strength, tests for gait and inter-limb coordination and neurological deficit scores. In this review, we share our thoughts on standardized data presentation to increase data comparability between studies. We also critically evaluate current methods and provide recommendations for choosing the best behavioral test for a new research line. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Evaluation of RAPID for a UNF cask benchmark problem

    Science.gov (United States)

    Mascolino, Valerio; Haghighat, Alireza; Roskoff, Nathan J.

    2017-09-01

    This paper examines the accuracy and performance of the RAPID (Real-time Analysis for Particle transport and In-situ Detection) code system for the simulation of a used nuclear fuel (UNF) cask. RAPID is capable of determining eigenvalue, subcritical multiplication, and pin-wise, axially-dependent fission density throughout a UNF cask. We study the source convergence based on the analysis of the different parameters used in an eigenvalue calculation in the MCNP Monte Carlo code. For this study, we consider a single assembly surrounded by absorbing plates with reflective boundary conditions. Based on the best combination of eigenvalue parameters, a reference MCNP solution for the single assembly is obtained. RAPID results are in excellent agreement with the reference MCNP solutions, while requiring significantly less computation time (i.e., minutes vs. days). A similar set of eigenvalue parameters is used to obtain a reference MCNP solution for the whole UNF cask. Because of time limitation, the MCNP results near the cask boundaries have significant uncertainties. Except for these, the RAPID results are in excellent agreement with the MCNP predictions, and its computation time is significantly lower, 35 second on 1 core versus 9.5 days on 16 cores.

  6. Uncertainty Evaluation of Residential Central Air-conditioning Test System

    Science.gov (United States)

    Li, Haoxue

    2018-04-01

    According to national standards, property tests of air-conditioning are required. However, test results could be influenced by the precision of apparatus or measure errors. Therefore, uncertainty evaluation of property tests should be conducted. In this paper, the uncertainties are calculated on the property tests of Xinfei13.6 kW residential central air-conditioning. The evaluation result shows that the property tests are credible.

  7. The impact of providing rapid diagnostic malaria tests on fever management in the private retail sector in Ghana: a cluster randomized trial.

    Science.gov (United States)

    Ansah, Evelyn K; Narh-Bana, Solomon; Affran-Bonful, Harriet; Bart-Plange, Constance; Cundill, Bonnie; Gyapong, Margaret; Whitty, Christopher J M

    2015-03-04

    To examine the impact of providing rapid diagnostic tests for malaria on fever management in private drug retail shops where most poor rural people with fever present, with the aim of reducing current massive overdiagnosis and overtreatment of malaria. Cluster randomized trial of 24 clusters of shops. Dangme West, a poor rural district of Ghana. Shops and their clients, both adults and children. Providing rapid diagnostic tests with realistic training. The primary outcome was the proportion of clients testing negative for malaria by a double-read research blood slide who received an artemisinin combination therapy or other antimalarial. Secondary outcomes were use of antibiotics and antipyretics, and safety. Of 4603 clients, 3424 (74.4%) tested negative by double-read research slides. The proportion of slide-negative clients who received any antimalarial was 590/1854 (32%) in the intervention arm and 1378/1570 (88%) in the control arm (adjusted risk ratio 0.41 (95% CI 0.29 to 0.58), Pretail sector significantly reduced dispensing of antimalarials to patients without malaria, did not reduce prescribing of antimalarials to true malaria cases, and appeared safe. Rapid diagnostic tests should be considered for the informal private drug retail sector.Registration Clinicaltrials.gov NCT01907672. © Ansah et al 2015.

  8. The Evaluation of Diagnostic Tests for Sexually Transmitted Infections

    Directory of Open Access Journals (Sweden)

    Max A Chernesky

    2005-01-01

    Full Text Available Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis -- sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  9. Health workers' compliance to rapid diagnostic tests (RDTs) to guide malaria treatment: a systematic review and meta-analysis

    NARCIS (Netherlands)

    Kabaghe, Alinune N.; Visser, Benjamin J.; Spijker, Rene; Phiri, Kamija S.; Grobusch, Martin P.; van Vugt, Michèle

    2016-01-01

    The World Health Organization recommends malaria to be confirmed by either microscopy or a rapid diagnostic test (RDT) before treatment. The correct use of RDTs in resource-limited settings facilitates basing treatment onto a confirmed diagnosis; contributes to speeding up considering a correct

  10. The Rapid Disaster Evaluation System (RaDES): A Plan to Improve Global Disaster Response by Privatizing the Assessment Component.

    Science.gov (United States)

    Iserson, Kenneth V

    2017-09-01

    Emergency medicine personnel frequently respond to major disasters. They expect to have an effective and efficient management system to elegantly allocate available resources. Despite claims to the contrary, experience demonstrates this rarely occurs. This article describes privatizing disaster assessment using a single-purposed, accountable, and well-trained organization. The goal is to achieve elegant disaster assessment, rather than repeatedly exhorting existing groups to do it. The Rapid Disaster Evaluation System (RaDES) would quickly and efficiently assess a postdisaster population's needs. It would use an accountable nongovernmental agency's teams with maximal training, mobility, and flexibility. Designed to augment the Inter-Agency Standing Committee's 2015 Emergency Response Preparedness Plan, RaDES would provide the initial information needed to avoid haphazard and overlapping disaster responses. Rapidly deployed teams would gather information from multiple sources and continually communicate those findings to their base, which would then disseminate them to disaster coordinators in a concise, coherent, and transparent way. The RaDES concept represents an elegant, minimally bureaucratic, and effective rapid response to major disasters. However, its implementation faces logistical, funding, and political obstacles. Developing and maintaining RaDES would require significant funding and political commitment to coordinate the numerous agencies that claim to be performing the same tasks. Although simulations can demonstrate efficacy and deficiencies, only field tests will demonstrate RaDES' power to improve interagency coordination and decrease the cost of major disaster response. At the least, the RaDES concept should serve as a model for discussing how to practicably improve our current chaotic disaster responses. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Digital radiographic evaluation of the midpalatal suture in patients submitted to rapid maxillary expansion

    Directory of Open Access Journals (Sweden)

    Maria de Fátima Batista de Melo

    2013-01-01

    Full Text Available Aims: To analyze the density of the midpalatal suture by means of digital radiographs three months after retention to evaluate if this period of retention is really sufficient for bone repair. Materials and Methods: This prospective study consisted of 31 patients (11 girls and 20 boys in the mixed or permanent dentition stage, treated using a tooth-tissue borne expanders (Haas. Occlusal digital radiographs were taken at three stages: prior to rapid maxillary expansion (Stage I; immediately after desired maxillary expansion (Stage II; and after three months of retention (Stage III. Radiographs were taken on a dental X-ray machine, set at 70 kVp and 7 mA with an exposure time of 0.04 s. A phosphor storage plate system, imaging plate size n. 2 (35 × 45 × 1.6 mm, was used. Three regions (A, B and C measured 0.02 mm² were selected for optical density analysis. The difference between the measurements was evaluated with the paired t-test. Results: The optical density was reduced at Stages II and III compared with Stage I. Between-stage comparison showed statistically significant changes for all variables (P < 0.05, with the highest mean optical density at Stage I and the lowest at Stage II, in all groups. Actually, there was an increase in optical density between Stages II and III, but they are reduced compared with Stage I. Conclusion: The results strongly suggest that bone formation did not occur as expected, and that a longer retention period for bone repair may be necessary.

  12. Three dimensional evaluation of alveolar bone changes in response to different rapid palatal expansion activation rates

    Directory of Open Access Journals (Sweden)

    Brian LaBlonde

    Full Text Available ABSTRACT Introduction: The aim of this multi-center retrospective study was to quantify the changes in alveolar bone height and thickness after using two different rapid palatal expansion (RPE activation protocols, and to determine whether a more rapid rate of expansion is likely to cause more adverse effects, such as alveolar tipping, dental tipping, fenestration and dehiscence of anchorage teeth. Methods: The sample consisted of pre- and post-expansion records from 40 subjects (age 8-15 years who underwent RPE using a 4-banded Hyrax appliance as part of their orthodontic treatment to correct posterior buccal crossbites. Subjects were divided into two groups according to their RPE activation rates (0.5 mm/day and 0.8 mm/day; n = 20 each group. Three-dimensional images for all included subjects were evaluated using Dolphin Imaging Software 11.7 Premium. Maxillary base width, buccal and palatal cortical bone thickness, alveolar bone height, and root angulation and length were measured. Significance of the changes in the measurements was evaluated using Wilcoxon signed-rank test and comparisons between groups were done using ANOVA. Significance was defined at p ≤ 0.05. Results: RPE activation rates of 0.5 mm per day (Group 1 and 0.8 mm per day (Group 2 caused significant increase in arch width following treatment; however, Group 2 showed greater increases compared to Group 1 (p < 0.01. Buccal alveolar height and width decreased significantly in both groups. Both treatment protocols resulted in significant increases in buccal-lingual angulation of teeth; however, Group 2 showed greater increases compared to Group 1 (p < 0.01. Conclusion: Both activation rates are associated with significant increase in intra-arch widths. However, 0.8 mm/day resulted in greater increases. The 0.8 mm/day activation rate also resulted in more increased dental tipping and decreased buccal alveolar bone thickness over 0.5 mm/day.

  13. Nuclear explosives testing readiness evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Valk, T.C.

    1993-09-01

    This readiness evaluation considers hole selection and characterization, verification, containment issues, nuclear explosive safety studies, test authorities, event operations planning, canister-rack preparation, site preparation, diagnostic equipment setup, device assembly facilities and processes, device delivery and insertion, emplacement, stemming, control room activities, readiness briefing, arming and firing, test execution, emergency response and reentry, and post event analysis to include device diagnostics, nuclear chemistry, and containment. This survey concludes that the LLNL program and its supporting contractors could execute an event within six months of notification, and a second event within the following six months, given the NET group`s evaluation and the following three restraints: (1) FY94 (and subsequent year) funding is essentially constant with FY93, (2) Preliminary work for the initial event is completed to the historical sic months status, (3) Critical personnel, currently working in dual use technologies, would be recallable as needed.

  14. Laboratory evaluation of a simple and rapid latex agglutination assay for the serodiagnosis of typhoid fever

    NARCIS (Netherlands)

    Abdoel, Theresia H.; Pastoor, Rob; Smits, Henk L.; Hatta, Mochammad

    2007-01-01

    A latex agglutination assay for the serodiagnosis of typhoid fever was evaluated on samples collected from patients with clinical suspicion of typhoid fever in South Sulawesi, Indonesia, where the disease is endemic. The latex assay is very easy to use, gives a rapid result and may be used as a

  15. Serodiagnosis of dengue infection using rapid immunochromatography test in patients with probable dengue infection.

    Science.gov (United States)

    Kidwai, Aneela Altaf; Jamal, Qaiser; Saher; Mehrunnisa; Farooqi, Faiz-ur-rehman; Saleem-Ullah

    2010-11-01

    To determine the frequency of seropositive dengue infection using rapid immunochromatographic assay in patients with probable dengue infection as per WHO criteria. A cross-sectional observational study was conducted at Abbasi Shaheed Hospital, Karachi from July 2008 to January 2009. Patients presenting with acute febrile illness, rashes, bleeding tendencies, leucopenia and or thrombocytopenia were evaluated according to WHO criteria for probable dengue infection. Acute phase sera were collected after 5 days of the onset of fever as per WHO criteria. Serology was performed using rapid immunochromatographic (ICT) assay with differential detection of IgM and IgG. A primary dengue infection was defined by a positive IgM band and a negative IgG band whereas secondary infection was defined by a positive IgG band with or without positive IgM band. Among 599 patients who met the WHO criteria for dengue infection, 251(41.9%) were found to be ICT reactive among whom 42 (16.73%) had primary infection. Secondary infection was reported in 209 (83.26%). Acute phase sera of 348 (58.09%) were ICT non reactive. Four patients died because of dengue shock syndrome among which three had secondary infection. Early identification of secondary infection in acute phase sera using rapid ICT is valuable in terms of disease progression and mortality. However in highly suspected cases of dengue infection clinical management should not rely on negative serological results.

  16. Classroom Evaluation of a Rapid Prototyping System.

    Science.gov (United States)

    Tennyson, Stephen A.; Krueger, Thomas J.

    2001-01-01

    Introduces rapid prototyping which creates virtual models through a variety of automated material additive processes. Relates experiences using JP System 5 in freshman and sophomore engineering design graphics courses. Analyzes strengths and limitations of the JP System 5 and discusses how to use it effectively. (Contains 15 references.)…

  17. Performance of the Quidel Sofia Rapid Influenza Diagnostic Test During the 2012-2013 and 2013-2014 Influenza Seasons

    Science.gov (United States)

    2016-03-23

    Performance of the Quidel Sofia rapid influenza diagnostic test during the 2012–2013 and 2013–2014 influenza seasons Peter E. Kammerer, Jennifer M... Influenza A+B Fluorescent Immunoassay was used to test nasal swab specimens from patients with influenza -like illness at US–Mexico border-area clinics in...the 2012–2013 and 2013–2014 influenza seasons. Compared with real-time reverse transcription polymerase chain reaction, the overall sensitivities and

  18. A Portable Environment Test System: A Field Assessment of Organotin Leachates--Test and Evaluation.

    Science.gov (United States)

    1987-11-01

    of organotin-based antifouling (AF) coatings, NOSC researchers used this facility to study the effects of tributyltin ( TBT ), the primary toxic ...Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) anti oling leachates in Sin Diego Bay over a 7-month period. Overall mean test...EXECUTIVE SUMMARY A Portable Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) antifouling leachates in San Diego Bay for 7

  19. Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III -- Grid Interconnection System Evaluator: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lundstrom, B.; Shirazi, M.; Coddington, M.; Kroposki, B.

    2013-01-01

    This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

  20. A simple kit for rapid field diagnosis of potato virus Y by latex serological test

    Directory of Open Access Journals (Sweden)

    Aarne Kurppa

    1987-07-01

    Full Text Available A simple kit for rapid detection of potato virus Y by latex serological test was developed. The test is carried out on a white cardboard sheet and the results can be read by naked eye in two minutes. A test card of 10 x 6 cm holds latex sensitized antibodies, buffers and other necessary ingredients as dry blue colored formulate on the ringed areas of the card. A test card includes space for six tests and positive and negative controls. The kit also includes disposable plastic sticks for mixing the samples with test reagents and a hand press with disposable plastic tips. For testing, dried reagents are dissolved in drops of sample and mixed. After gentle rotation, samples containing virus appear clearly granulated while samples from healthy plants remain unagglutinated. The testing of undiluted extracts of evenly developed tuber sprouts resulted in over 91 % identity with the results obtained with ELISA that was used as a control method. Testing of diluted leaf extracts reached the same reliability but undiluted leaf extracts from glasshouse grown potatoes were not well suitable as test samples because of their dark green color. No such problems occurred with field grown material and a complete identity with the ELISA readings was true when the samples included secondarily infected potato plants. No reaction to other potato viruses than PVY was obtained by the test kit.

  1. Evaluate of head loss, sediment value and copper removal in sand media (rapid sand filter

    Directory of Open Access Journals (Sweden)

    Daneshi Navab

    2014-06-01

    Full Text Available Along with the technology development and increasing consumption of water resources, we are experiencing low qualities in the mentioned resources. Copper brings about serious environment al pollution, threatening human health and ecosystem. This metal found variously in water resources and industrial activities. Therefore, it needs to treat the water resources from these excessive amounts. Different methods have used for this reason but the most used method during recent years has been the absorption by economic absorbers such as sand. Rapid sand filters usually used in water and wastewater treatment plants for water clarification. In this research, a single layer gravity rapid sand filter has used to reduce different concentrations of copper. sediment value and head loss arising in filter media is simulated by using combination of Carman-Kozeny, Rose and Gregory models in different discharges of rapid sand filter. Results have shown that with increasing in discharge and decreasing in input copper concentration, arriving time to given head loss, is increasing. In addition, results demonstrated that with increasing in copper concentration in influent, removal efficiency is decreasing somewhat. Results of this research can applied in an appropriate design of rapid sand filter to copper removal, a prediction of rapid sand filter ability to copper removal and an estimation of arising head loss during filter work thus evaluating of time interval backwash. DOI: http://dx.doi.org/10.3126/ije.v3i2.10641 International Journal of the Environment Vol.3(2 2014: 276-286

  2. Evaluation of RAPID for a UNF cask benchmark problem

    Directory of Open Access Journals (Sweden)

    Mascolino Valerio

    2017-01-01

    Full Text Available This paper examines the accuracy and performance of the RAPID (Real-time Analysis for Particle transport and In-situ Detection code system for the simulation of a used nuclear fuel (UNF cask. RAPID is capable of determining eigenvalue, subcritical multiplication, and pin-wise, axially-dependent fission density throughout a UNF cask. We study the source convergence based on the analysis of the different parameters used in an eigenvalue calculation in the MCNP Monte Carlo code. For this study, we consider a single assembly surrounded by absorbing plates with reflective boundary conditions. Based on the best combination of eigenvalue parameters, a reference MCNP solution for the single assembly is obtained. RAPID results are in excellent agreement with the reference MCNP solutions, while requiring significantly less computation time (i.e., minutes vs. days. A similar set of eigenvalue parameters is used to obtain a reference MCNP solution for the whole UNF cask. Because of time limitation, the MCNP results near the cask boundaries have significant uncertainties. Except for these, the RAPID results are in excellent agreement with the MCNP predictions, and its computation time is significantly lower, 35 second on 1 core versus 9.5 days on 16 cores.

  3. Evaluation of a new in-clinic test system to detect feline immunodeficiency virus and feline leukemia virus infection.

    Science.gov (United States)

    Sand, Christina; Englert, Theresa; Egberink, Herman; Lutz, Hans; Hartmann, Katrin

    2010-06-01

    Many in-house tests for the diagnosis of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infection are licensed for use in veterinary practice. A new test with unknown performance has recently appeared on the market. The aims of this study were to define the efficacy of a new in-clinic test system, the Anigen Rapid FIV Ab/FeLV Ag Test, and to compare it with the current leading in-clinic test, the SNAP Kombi Plus FeLV Antigen/FIB Antibody Test. Three-hundred serum samples from randomly selected healthy and diseased cats presented to the Clinic of Small Animal Medicine at Ludwig Maximilian University were tested using both the Anigen Rapid Test and the SNAP Kombi Plus Test. Diagnostic sensitivity, specificity, and positive and negative predictive values were calculated for both tests using Western blot as the gold standard for verification of FIV infection and PCR as the gold standard for FeLV infection. The presence of antibodies against FIV was confirmed by Western blot in 9/300 samples (prevalence 3%). FeLV DNA was detected by PCR in 15/300 samples (prevalence 5%). For FIV infection the Anigen Rapid Test had a sensitivity of 88.9%, specificity of 99.7%, positive predictive value of 88.9%, and negative predictive value of 99.7%. For FeLV infection, the Anigen Rapid Test had a sensitivity of 40.0%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 96.9%. Diagnostic accuracy was similar to that of the SNAP Kombi Plus Test. The new Anigen Rapid FIV Ab/FeLV Ag Test performed very well and can be recommended for use in veterinary practice.

  4. A method for rapid testing of the photosynthesis-inhibiting activity of herbicides by leaf disk infiltration

    Directory of Open Access Journals (Sweden)

    Krzysztof Bielecki

    2013-12-01

    Full Text Available A method for rapid detection of photosynthesis inhibitors in low concentration (0.25-1.25 ppm was developed. The experiments were performed on disks cut from young bean leaves. The disks were infiltrated with solutions of the tested compounds and placed at the bottom of a crystallizer containing an acidic sodium carbonate solution and then illuminated. The toxicity of the tested substance was measured as the number of disks corning to the surface. It was found that linuron, monolinuron, metoksuron, atrazine and prometrine inhibited floating of the disks, whereas 2,4,5-T, MCPA and chlorpropham gave no effect. This confirms the specificity of the test which is appropriate for determining the phytotoxicity of typical photosynthesis inhibitors.

  5. Evaluation of the microscopic observational drug susceptibility assay for rapid and efficient diagnosis of multi-drug resistant tuberculosis

    Directory of Open Access Journals (Sweden)

    R P Lazarus

    2012-01-01

    Full Text Available Purpose: Tuberculosis (TB is endemic in India and the burden of multi-drug-resistant tuberculosis (MDR-TB is high. Early detection of MDR-TB is of primary importance in controlling the spread of TB. The microscopic observational drug susceptibility (MODS assay has been described as a cost-effective and rapid method by which mycobacterial culture and the drug susceptibility test (DST can be done at the same time. Materials and Methods: A total of 302 consecutive sputum samples that were received in an accredited mycobacteriology laboratory for conventional culture and DST were evaluated by the MODS assay. Results: In comparison with conventional culture on Lowenstein Jensen (LJ media, the MODS assay showed a sensitivity of 94.12% and a specificity of 89.39% and its concordance with the DST by the proportion method on LJ media to isoniazid and rifampicin was 90.8% and 91.5%, respectively. The turnaround time for results by MODS was 9 days compared to 21 days by culture on LJ media and an additional 42 days for DST by the 1% proportion method. The cost of performing a single MODS assay was Rs. 250/-, compared to Rs. 950/- for culture and 1st line DST on LJ. Conclusion: MODS was found to be a sensitive and rapid alternative method for performing culture and DST to identify MDR-TB in resource poor settings.

  6. Rapid microbiological testing: monitoring the development of bacterial stress.

    Directory of Open Access Journals (Sweden)

    Boris Zavizion

    2010-10-01

    Full Text Available The ability to respond to adverse environments effectively along with the ability to reproduce are sine qua non conditions for all sustainable cellular forms of life. Given the availability of an appropriate sensing modality, the ubiquity and immediacy of the stress response could form the basis for a new approach for rapid biological testing. We have found that measuring the dielectric permittivity of a cellular suspension, an easily measurable electronic property, is an effective way to monitor the response of bacterial cells to adverse conditions continuously. The dielectric permittivity of susceptible and resistant strains of Escherichia coli and Staphylococcus aureus, treated with gentamicin and vancomycin, were measured directly using differential impedance sensing methods and expressed as the Normalized Impedance Response (NIR. These same strains were also heat-shocked and chemically stressed with Triton X-100 or H(2O(2. The NIR profiles obtained for antibiotic-treated susceptible organisms showed a strong and continuous decrease in value. In addition, the intensity of the NIR value decrease for susceptible cells varied in proportion to the amount of antibiotic added. Qualitatively similar profiles were found for the chemically treated and heat-shocked bacteria. In contrast, antibiotic-resistant cells showed no change in the NIR values in the presence of the drug to which it is resistant. The data presented here show that changes in the dielectric permittivity of a cell suspension are directly correlated with the development of a stress response as well as bacterial recovery from stressful conditions. The availability of a practical sensing modality capable of monitoring changes in the dielectric properties of stressed cells could have wide applications in areas ranging from the detection of bacterial infections in clinical specimens to antibiotic susceptibility testing and drug discovery.

  7. Improvement of test methodology for evaluating diesel fuel stability

    Energy Technology Data Exchange (ETDEWEB)

    Gutman, M.; Tartakovsky, L.; Kirzhner, Y.; Zvirin, Y. [Internal Combustion Engines Lab., Haifa (Israel); Luria, D. [Fuel Authority, Tel Aviv (Israel); Weiss, A.; Shuftan, M. [Israel Defence Forces, Tel Aviv (Israel)

    1995-05-01

    The storage stability of diesel fuel has been extensively investigated for many years under laboratory conditions. Although continuous efforts have been made to improve testing techniques, there does not yet exist a generally accepted correlation between laboratory methods (such as chemical analysis of the fuel) and actual diesel engine tests. A testing method was developed by the Technion Internal Combustion Engines Laboratory (TICEL), in order to address this problem. The test procedure was designed to simulate diesel engine operation under field conditions. It is based on running a laboratory-modified single cylinder diesel engine for 50 h under cycling operating conditions. The overall rating of each test is based on individual evaluation of the deposits and residue formation in the fuel filter, nozzle body and needle, piston head, piston rings, exhaust valve, and combustion chamber (six parameters). Two methods for analyzing the test results were used: objective, based on measured data, and subjective, based on visual evaluation results of these deposits by a group of experts. Only the residual level in the fuel filter was evaluated quantitatively by measured results. In order to achieve higher accuracy of the method, the test procedure was improved by introducing the measured results of nozzle fouling as an additional objective evaluating (seventh) parameter. This factor is evaluated on the basis of the change in the air flow rate through the nozzle before and after the complete engine test. Other improvements in the method include the use of the nozzle assembly photograph in the test evaluation, and representation of all seven parameters on a continuous scale instead of the discrete scale used anteriorly, in order to achieve higher accuracy. This paper also contains the results obtained by application of this improved fuel stability test for a diesel fuel stored for a five-year period.

  8. Development of in-pile test and evaluation technology

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yung Hwan; Park, Jong Man; Joo, Kee Nam; Park, Duk Keun; Park, Se Jin; Oh, Jong Myung; Kim, Tae Ryong; Park Jin Suk; Lee, Jae Han [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-08-01

    To develop the in-pile test and evaluation technologies using KMRR, basic design of instrumented capsule and auxiliary system for material irradiation test and the related studies are performed. First, reactor and test hole characteristics are summarized, and conceptual design requirements of capsule to KMRR are reviewed. And fundamental principles and criteria for the instrumented capsule design are summarized. Basic design and analysis of instrumented capsule are performed, and design of capsule supporting system are also performed and structural integrity of the system is analyzed. Based on the prior studies, test mock-ups are designed and manufactured, and thermohydraulic and vibration tests are prepared. And, as in-pile test evaluation technologies, KMRR neutron dosimetry and mechanical tests related to material irradiation are investigated. 67 figs, 30 tabs, 41 refs. (Author).

  9. Personal Radiation Detector Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Chris A. Hodge, Ding Yuan, Raymond P. Keegan, Michael A. Krstich

    2007-01-01

    Following the success of the Anole test of portable detection system, the U.S. Department of Homeland Security (DHS) Domestic Nuclear Detection Office organized a test and evaluation campaign for personal radiation detectors (PRDs), also known as 'Pagers'. This test, 'Bobcat', was conducted from July 17 to August 8, 2006, at the Nevada Test Site. The Bobcat test was designed to evaluate the performance of PRDs under various operational scenarios, such as pedestrian surveying, mobile surveying, cargo container screening, and pedestrian chokepoint monitoring. Under these testing scenarios, many operational characteristics of the PRDs, such as gamma and neutron sensitivities, positive detection and false alarm rates, response delay times, minimum detectable activities, and source localization errors, were analyzed. This paper will present the design, execution, and methodologies used to test this equipment for the DHS

  10. Rapid screening of aquatic toxicity of several metal-based nanoparticles using the MetPLATE™ bioassay

    International Nuclear Information System (INIS)

    Pokhrel, Lok R.; Silva, Thilini; Dubey, Brajesh; El Badawy, Amro M.; Tolaymat, Thabet M.; Scheuerman, Phillip R.

    2012-01-01

    Current understanding of potential toxicity of engineered nanomaterials to aquatic microorganisms is limited for risk assessment and management. Here we evaluate if the MetPLATE™ test can be used as an effective and rapid screening tool to test for potential aquatic toxicity of various metal-based nanoparticles (NPs). The MetPLATE bioassay is a heavy metal sensitive test based on β-galactosidase activity in Escherichia coli. Five different types of metal-based NPs were screened for toxicity: (1) citrate coated nAg (Citrate-nanosilver), (2) polyvinylpyrrolidone coated nAg (PVP-nAg), (3) uncoated nZnO, (4) uncoated nTiO 2 and (5) 1-Octadecylamine coated CdSe Quantum Dots (CdSe QDs); and compared with their corresponding ionic salt toxicity. Citrate-nAg was further fractionated into clean Citrate-nAg, unclean Citrate-nAg and permeate using a tangential flow filtration (TFF) system to eliminate residual ions and impurities from the stock Citrate-nAg suspension and also to differentiate between ionic- versus nano-specific toxicity. Our results showed that nAg, nZnO and CdSe QDs were less toxic than their corresponding ionic salts tested, while nano- or ionic form of TiO 2 was not toxic as high as 2.5 g L −1 to the MetPLATE™ bacteria. Although coating-dependent toxicity was noticeable between two types of Ag NPs evaluated, particle size and surface charge were not adequate to explain the observed toxicity; hence, the toxicity appeared to be material-specific. Overall, the toxicity followed the trend: CdCl 2 > AgNO 3 > PVP-nAg > unclean Citrate-nAg > clean Citrate-nAg > ZnSO 4 > nZnO > CdSe QDs > nTiO 2 /TiO 2 . These results indicate that an evaluation of β-galactosidase inhibition in MetPLATE™ E. coli can be an important consideration for rapid screening of metal-based NP toxicity, and should facilitate ecological risk assessment of these emerging contaminants. - Highlights: ► MetPLATE bioassay was evaluated as a rapid screening tool for nanotoxicity.

  11. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    International Nuclear Information System (INIS)

    Hovi, T.; Roivainen, M.

    1989-01-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with 51 Cr, [ 3 H]leucine, or, preferentially, with [ 3 H]uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30 degree C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well

  12. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    Science.gov (United States)

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  13. CARES (Computer Analysis for Rapid Evaluation of Structures) Version 1.0, seismic module

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulas, A.J.; Miller, C.A.; Costantino, C.J.

    1990-07-01

    During FY's 1988 and 1989, Brookhaven National Laboratory (BNL) developed the CARES system (Computer Analysis for Rapid Evaluation of Structures) for the US Nuclear Regulatory Commission (NRC). CARES is a PC software system which has been designed to perform structural response computations similar to those encountered in licensing reviews of nuclear power plant structures. The documentation of the Seismic Module of CARES consists of three volumes. This report is Volume 2 of the three volume documentation of the Seismic Module of CARES and represents the User's Manual. 14 refs

  14. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    Science.gov (United States)

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Rapid Tooling via Stereolithography

    OpenAIRE

    Montgomery, Eva

    2006-01-01

    Approximately three years ago, composite stereolithography (SL) resins were introduced to the marketplace, offering performance features beyond what traditional SL resins could offer. In particular, the high heat deflection temperatures and high stiffness of these highly filled resins have opened the door to several new rapid prototyping (RP) applications, including wind tunnel test modelling and, more recently, rapid tooling.

  16. Standard guide for in-plant performance evaluation of automatic pedestrian SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This guide is affiliated with Guide C1112 on special nuclear material (SNM) monitors, Guide C1169 on laboratory performance evaluation, and Guide C1189 on calibrating pedestrian SNM monitors. This guide to in-plant performance evaluation is a comparatively rapid way to verify whether a pedestrian SNM monitor performs as expected for detecting SNM or SNM-like test sources. 1.1.1 In-plant performance evaluation should not be confused with the simple daily functional test recommended in Guide C1112. In-plant performance evaluation takes place less often than daily tests, usually at intervals ranging from weekly to once every three months. In-plant evaluations are also more extensive than daily tests and may examine both a monitor's nuisance alarm record and its detection sensitivity for a particular SNM or alternative test source. 1.1.2 In-plant performance evaluation also should not be confused with laboratory performance evaluation. In-plant evaluation is comparatively rapid, takes place in the monitor...

  17. Rapid evaluation of buildings and infrastructure to accidental and deliberate aircraft impact

    International Nuclear Information System (INIS)

    Tennant, D.; Levine, H.; Mould, J.; Vaughan, D.

    2014-01-01

    Recent events involving the impact of large transport aircraft such as the Boeing 767 and 757 into the World Trade Center Towers and the Pentagon have revealed the vulnerability of such structures to terrorist attack. Incidents involving smaller general aviation aircraft have shown the damage that this class of plane can do beyond a protected perimeter. These incidents have elicited inquiries with regard to the effects of impacts of these aircraft types into other critical facilities including aboveground and below ground storage facilities, nuclear power plants, damns and other military and civilian installations. A significant capability to evaluate these threats has been developed during the past 10 years. Small medium and large aircraft have been impacted into buried and aboveground reinforced concrete and light steel frame storage facilities. Both explicit aircraft models and Riera functions (a simplified aircraft impact loading function) have been used to generate an extensive data base. The effects of engines impacting have been studied separately as penetrators. Illustrated in this paper is validation of computational tools for impacts into structures and the initial development of a generalized evaluation tool for rapid evaluation of threats and consequence of aircraft impact into protected facilities

  18. Rapid evaluation of buildings and infrastructure to accidental and deliberate aircraft impact

    Energy Technology Data Exchange (ETDEWEB)

    Tennant, D., E-mail: tennant@wai.com [Weidlinger Associates, Inc., 6301 Indian School Road NE, Suite 501, Albuquerque, NM 87122 (United States); Levine, H., E-mail: levine@ca.wai.com [Weidlinger Associates, Inc., 399 W. El Camino Real, Suite 200, Mountain View, CA 94040 (United States); Mould, J.; Vaughan, D. [Weidlinger Associates, Inc., 399 W. El Camino Real, Suite 200, Mountain View, CA 94040 (United States)

    2014-04-01

    Recent events involving the impact of large transport aircraft such as the Boeing 767 and 757 into the World Trade Center Towers and the Pentagon have revealed the vulnerability of such structures to terrorist attack. Incidents involving smaller general aviation aircraft have shown the damage that this class of plane can do beyond a protected perimeter. These incidents have elicited inquiries with regard to the effects of impacts of these aircraft types into other critical facilities including aboveground and below ground storage facilities, nuclear power plants, damns and other military and civilian installations. A significant capability to evaluate these threats has been developed during the past 10 years. Small medium and large aircraft have been impacted into buried and aboveground reinforced concrete and light steel frame storage facilities. Both explicit aircraft models and Riera functions (a simplified aircraft impact loading function) have been used to generate an extensive data base. The effects of engines impacting have been studied separately as penetrators. Illustrated in this paper is validation of computational tools for impacts into structures and the initial development of a generalized evaluation tool for rapid evaluation of threats and consequence of aircraft impact into protected facilities.

  19. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    Science.gov (United States)

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  20. Test plan for FY-91 alpha CAM evaluation

    International Nuclear Information System (INIS)

    Winberg, M.R.

    1991-03-01

    This report describes the test plan for evaluating the Merlin Gerin, Inc., Edgar alpha continuous air monitor (CAM) and associated analysis system to be conducted by Idaho National Engineering Laboratory (INEL) for the Department of Energy. INEL has evaluated other commercial alpha CAM systems to detect transuranic contaminants during waste handling and retrieval operations. This test plan outlines experimental methods, sampling methods, sampling and analysis techniques, and equipment needed and safety and quality requirements to test the commercial CAM. 8 refs., 3 figs

  1. Romer Labs RapidChek®Listeria monocytogenes Test System for the Detection of L. monocytogenes on Selected Foods and Environmental Surfaces.

    Science.gov (United States)

    Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T

    2018-04-27

    The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.

  2. Development, Evaluation, and Integration of a Quantitative Reverse-Transcription Polymerase Chain Reaction Diagnostic Test for Ebola Virus on a Molecular Diagnostics Platform.

    Science.gov (United States)

    Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B; Nauwelaers, David; Ariën, Kevin K

    2016-10-15

     The 2013-2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV).  The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus.  The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%.  The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  3. Rapid improvement teams.

    Science.gov (United States)

    Alemi, F; Moore, S; Headrick, L; Neuhauser, D; Hekelman, F; Kizys, N

    1998-03-01

    Suggestions, most of which are supported by empirical studies, are provided on how total quality management (TQM) teams can be used to bring about faster organizationwide improvements. Ideas are offered on how to identify the right problem, have rapid meetings, plan rapidly, collect data rapidly, and make rapid whole-system changes. Suggestions for identifying the right problem include (1) postpone benchmarking when problems are obvious, (2) define the problem in terms of customer experience so as not to blame employees nor embed a solution in the problem statement, (3) communicate with the rest of the organization from the start, (4) state the problem from different perspectives, and (5) break large problems into smaller units. Suggestions for having rapid meetings include (1) choose a nonparticipating facilitator to expedite meetings, (2) meet with each team member before the team meeting, (3) postpone evaluation of ideas, and (4) rethink conclusions of a meeting before acting on them. Suggestions for rapid planning include reducing time spent on flowcharting by focusing on the future, not the present. Suggestions for rapid data collection include (1) sample patients for surveys, (2) rely on numerical estimates by process owners, and (3) plan for rapid data collection. Suggestions for rapid organizationwide implementation include (1) change membership on cross-functional teams, (2) get outside perspectives, (3) use unfolding storyboards, and (4) go beyond self-interest to motivate lasting change in the organization. Additional empirical investigations of time saved as a consequence of the strategies provided are needed. If organizations solve their problems rapidly, fewer unresolved problems may remain.

  4. Utility of dengue NS1 antigen rapid diagnostic test for use in difficult to reach areas and its comparison with dengue NS1 ELISA and qRT-PCR.

    Science.gov (United States)

    Shukla, Mohan K; Singh, Neeru; Sharma, Ravendra K; Barde, Pradip V

    2017-07-01

    The objective of this study was to demonstrate the utility of dengue virus (DENV) non structural protein 1 (NS1) based rapid diagnostic test (RDT) for use in tribal and difficult to reach areas for early dengue (DEN) diagnosis in acute phase patients and evaluate its sensitivity and specificity against DENV NS1 enzyme linked immune sorbent assay (ELISA) and real time reverse transcriptase polymerase chain reaction (qRT-PCR). The DENV NS1 RDT was used for preliminary diagnosis during outbreaks in difficult to reach rural and tribal areas. The diagnosis was confirmed by DENV NS1 ELISA in the laboratory. The samples were also tested and serotyped by qRT-PCR. The results were evaluated using statistical tests. The DENV NS1 RDT showed 99.2% sensitivity and 96.0% specificity when analyzed using DENV NS1 ELISA as standard. The specificity and sensitivity of the RDT when compared with qRT-PCR was 93.6% and 91.1%, respectively. The serotype specific evaluation showed more than 90% sensitivity and specificity for DENV-1, 2, and 3. The RDT proved a good diagnostic tool in difficult to reach rural and tribal areas. Further evaluation studies with different commercially available RDTs in different field conditions are essential, that will help clinicians and patients for treatment and programme managers for timely intervention. © 2017 Wiley Periodicals, Inc.

  5. Implementation of universal rapid human immunodeficiency virus screening on labor and delivery.

    Science.gov (United States)

    Crochet, Stacia; Huang, Chun-Chih; Fries, Melissa; Scott, Rachel K

    2018-03-01

    A case of mother to child transmission (MTCT) of HIV at a medical center in Washington, DC, resulted in the implementation of universal opt-out rapid testing of patients admitted for delivery. This article evaluates the policy's efficacy and implementation. We evaluated the implementation using the Reach, Efficacy, Adoption, Implementation, and Maintenance (RE-AIM) framework. We could not evaluate decrease in MTCT rate secondary to low sample size ( n  = 3324) and no true-positive results. Patients not tested ( n  = 458) were predominately secondary to physician omission (93.7%) and were more likely to be White ( p  < 0.01) and older ( p  < 0.01). There was a negative relationship with physician omission over time. The policy was successfully implemented with decreasing proportions of patients not tested. Earlier inclusion of testing into standard admission orders and nurse-based approach may have expedited adoption. Given the low incidence of new HIV diagnosis in labor, we were unable to assess decrease in MTCT.

  6. Appropriate targeting of artemisinin-based combination therapy by community health workers using malaria rapid diagnostic tests

    DEFF Research Database (Denmark)

    Ndyomugyenyi, Richard; Magnussen, Pascal; Lal, Sham

    2016-01-01

    OBJECTIVE: To compare the impact of malaria rapid diagnostic tests (mRDTs), used by community health workers (CHWs), on the proportion of children ...-randomized trials were conducted in two contrasting areas of moderate-to-high and low malaria transmission in rural Uganda. Each trial examined the effectiveness of mRDTs in the management of malaria and targeting of ACTs by CHWs comparing two diagnostic approaches: (i) presumptive clinical diagnosis of malaria...

  7. Economic Evaluations of Pathology Tests, 2010-2015: A Scoping Review.

    Science.gov (United States)

    Watts, Rory D; Li, Ian W; Geelhoed, Elizabeth A; Sanfilippo, Frank M; St John, Andrew

    2017-09-01

    Concerns about pathology testing such as the value provided by new tests and the potential for inappropriate utilization have led to a greater need to assess costs and benefits. Economic evaluations are a formal method of analyzing costs and benefits, yet for pathology tests, questions remain about the scope and quality of the economic evidence. To describe the extent and quality of published evidence provided by economic evaluations of pathology tests from 2010 to 2015. Economic evaluations relating to pathology tests from 2010 to 2015 were reviewed. Eight databases were searched for published studies, and details recorded for the country, clinical focus, type of testing, and consideration of sensitivity, specificity, and false test results. The reporting quality of studies was assessed using the Consolidated Health Economic Evaluation Reporting Standards checklist and cost-effectiveness ratios were analyzed for publication bias. We found 356 economic evaluations of pathology tests, most of which regarded developed countries. The most common economic evaluations were cost-utility analyses and the most common clinical focus was infectious diseases. More than half of the studies considered sensitivity and specificity, but few studies considered the impact of false test results. The average Consolidated Health Economic Evaluation Reporting Standards checklist score was 17 out of 24. Cost-utility ratios were commonly less than $10,000/quality-adjusted life-year or more than $200,000/quality-adjusted life-year. The number of economic evaluations of pathology tests has increased in recent years, but the rate of increase has plateaued. Furthermore, the quality of studies in the past 5 years was highly variable, and there is some question of publication bias in reporting cost-effectiveness ratios. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  8. Evaluation of repetitive-PCR and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for rapid strain typing of Bacillus coagulans.

    Science.gov (United States)

    Sato, Jun; Nakayama, Motokazu; Tomita, Ayumi; Sonoda, Takumi; Hasumi, Motomitsu; Miyamoto, Takahisa

    2017-01-01

    In order to establish rapid and accurate typing method for Bacillus coagulans strains which is important for controlling in some canned foods and tea-based beverages manufacturing because of the high-heat resistance of the spores and high tolerance of the vegetative cells to catechins and chemicals, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and repetitive-PCR (rep-PCR) were evaluated. For this purpose, 28 strains of B. coagulans obtained from various culture collections were tested. DNA sequence analyses of the genes encoding 16S rRNA and DNA gyrase classified the test strains into two and three groups, respectively, regardless of their phenotypes. Both MALDI-TOF MS and rep-PCR methods classified the test strains in great detail. Strains classified in each group showed similar phenotypes, such as carbohydrate utilization determined using API 50CH. In particular, the respective two pairs of strains which showed the same metabolic characteristic were classified into the same group by both MALDI-TOF MS and rep-PCR methods separating from the other strains. On the other hand, the other strains which have the different profiles of carbohydrate utilization were separated into different groups by these methods. These results suggested that the combination of MALDI-TOF MS and rep-PCR analyses was advantageous for the rapid and detailed typing of bacterial strains in respect to both phenotype and genotype.

  9. Rapid detection, characterization, and enumeration of foodborne pathogens

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey

    2011-01-01

    . The present review discusses the reasons for the increasing interest in rapid methods; current developments in the field, the research needs, and the future trends. The advent of biotechnology has introduced new technologies that led to the emergence of rapid diagnostic methods and altered food testing...... of rapid methods is for fast screening of large number of samples, where most of them are expected to be test-negative, leading to faster product release for sale. This has been the main strength of rapid methods such as real-time Polymerase Chain Reaction (PCR). Enrichment PCR, where a primary culture...... of pathogen in a contaminated product. Another key issue is automation, where the key drivers are miniaturization and multiple testing, which mean that not only one instrument is flexible enough to test for many pathogens but also many pathogens can be detected with one test. The review is mainly based...

  10. How Rapid is Rapid Prototyping? Analysis of ESPADON Programme Results

    Directory of Open Access Journals (Sweden)

    Ian D. Alston

    2003-05-01

    Full Text Available New methodologies, engineering processes, and support environments are beginning to emerge for embedded signal processing systems. The main objectives are to enable defence industry to field state-of-the-art products in less time and with lower costs, including retrofits and upgrades, based predominately on commercial off the shelf (COTS components and the model-year concept. One of the cornerstones of the new methodologies is the concept of rapid prototyping. This is the ability to rapidly and seamlessly move from functional design to the architectural design to the implementation, through automatic code generation tools, onto real-time COTS test beds. In this paper, we try to quantify the term “rapid” and provide results, the metrics, from two independent benchmarks, a radar and sonar beamforming application subset. The metrics show that the rapid prototyping process may be sixteen times faster than a conventional process.

  11. A rapid radioimmunoassay for insulin suitable for testing pancreatic tissue prior to transplantation

    International Nuclear Information System (INIS)

    Besch, W.; Kohnert, K.-D.; Hahn, H.-J.; Ziegler, M.; Lorenz, D.

    1984-01-01

    One way of diabetes mellitus treatment is the transplantation of insulin-producing tissue. As islet or pancreas transplantation has made progress, testing of the tissue for its vitality, insulin content and insulin secretory response prior to transplantation became necessary. Apart from problems of rejection of allografted tissue, improvement of the patients metabolic control partly depends on the insulin content of the tissue transplanted. It was the aim of the present work to establish a radioimmunoassay which ensures rapid determination of immunoreactive insulin concentrations (IRI) either intracellularly-stored or released upon stimulation of human pancreas or islet with glucose, and to demonstrate the useful application of this assay for the assessment of transplantable tissue. (Auth.)

  12. A standard screening test for the early and rapid diagnosis of leptospirosis

    Directory of Open Access Journals (Sweden)

    Chandrasekaran S

    2004-01-01

    Full Text Available PURPOSE : To perform dark field microscopy (DFM for detection of Leptospira and to validate the results using Leptospira IgM antibody SERION ELISA test. METHODS : After differential centrifugation of Ruys, DFM was done to demonstrate Leptospira in the blood and SERION ELISA was done for Leptospira IgM antibody in single or paired serum samples. One hundred and eleven cases (39 adults and 72 children of suspected leptospirosis were included in the study. RESULTS : Anicteric cases accounted for 66.7% (26/39 of adults and complications involving brain, liver, kidney and eyes were seen in 33.3% (13/39. In children, 90.3% (65/72 were anicteric and involvement of brain and liver was seen in 9.7% (7/72 cases. On testing 60 single samples of blood from 23 adults and 37 children, DFM exhibited greater sensitivity of 93.3% (56/60 than that of SERION ELISA for Leptospira IgM antibody (33.3%, 20/60. It was observed that the positivity of DFM decreased from 100% (15/15 to 90.9% (10/11 with increase in the duration of infection for more than one week. ELISA for Leptospira IgM, done on 51 paired blood samples, was positive in 64.7% (33/51 cases when both (first and second samples were tested while in 45.1% (23/51 cases was positive with first sample alone. 58.8%(30/51 cases were positive by testing second sample. DFM results on paired blood samples showed persistence of Leptospira in 92.9% of cases. CONCLUSION : This study shows the validation of DFM results by SERION ELISA for Leptospira IgM antibody, based on which we recommend that DFM can serve as a standard screening test for early and rapid diagnosis of leptospirosis.

  13. Bacterial Cytological Profiling (BCP as a Rapid and Accurate Antimicrobial Susceptibility Testing Method for Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    D.T. Quach

    2016-02-01

    Full Text Available Successful treatment of bacterial infections requires the timely administration of appropriate antimicrobial therapy. The failure to initiate the correct therapy in a timely fashion results in poor clinical outcomes, longer hospital stays, and higher medical costs. Current approaches to antibiotic susceptibility testing of cultured pathogens have key limitations ranging from long run times to dependence on prior knowledge of genetic mechanisms of resistance. We have developed a rapid antimicrobial susceptibility assay for Staphylococcus aureus based on bacterial cytological profiling (BCP, which uses quantitative fluorescence microscopy to measure antibiotic induced changes in cellular architecture. BCP discriminated between methicillin-susceptible (MSSA and -resistant (MRSA clinical isolates of S. aureus (n = 71 within 1–2 h with 100% accuracy. Similarly, BCP correctly distinguished daptomycin susceptible (DS from daptomycin non-susceptible (DNS S. aureus strains (n = 20 within 30 min. Among MRSA isolates, BCP further identified two classes of strains that differ in their susceptibility to specific combinations of beta-lactam antibiotics. BCP provides a rapid and flexible alternative to gene-based susceptibility testing methods for S. aureus, and should be readily adaptable to different antibiotics and bacterial species as new mechanisms of resistance or multidrug-resistant pathogens evolve and appear in mainstream clinical practice.

  14. Adolescents' experience of a rapid HIV self-testing device in youth-friendly clinic settings in Cape Town South Africa: a cross-sectional community based usability study.

    Science.gov (United States)

    Smith, Philip; Wallace, Melissa; Bekker, Linda-Gail

    2016-12-23

    Introduction : Since HIV testing in South African adolescents and young adults is sub-optimal, the objective of the current study was to investigate the feasibility and acceptability of an HIV rapid self-testing device in adolescents and young people at the Desmond Tutu HIV Foundation Youth Centre and Mobile Clinic. Methods : Self-presenting adolescents and young adults were invited to participate in a study investigating the fidelity, usability and acceptability of the AtomoRapid HIV Rapid self-testing device. Trained healthcare workers trained participants to use the device before the participant conducted the HIV self-test with device usage instructions. The healthcare worker then conducted a questionnaire-based survey to assess outcomes. Results : Of the 224 enrolled participants between 16 and 24 years of age, 155 (69,2%) were female. Overall, fidelity was high; 216 (96,4%) participants correctly completed the test and correctly read and interpreted the HIV test result. There were eight (3,6%) user errors overall; six participants failed to prick their finger even though the lancet fired correctly. There were two user errors where participants failed to use the capillary tube correctly. Participants rated acceptability and usability highly, with debut testers giving significantly higher ratings for both. Younger participants gave significantly higher ratings of acceptability. Conclusions : Adolescents and young adults found HIV self-testing highly acceptable with the AtomoRapid and they used the device accurately. Further research should investigate how, where and when to deploy HIV self-testing as a means to accompany existing strategies in reaching the UNAIDS goal to test 90% of all individuals worldwide.

  15. When rapid adaptation paradigm is not too rapid: Evidence of face-sensitive N170 adaptation effects.

    Science.gov (United States)

    Tian, Tengxiang; Feng, Xue; Feng, Chunliang; Gu, Ruolei; Luo, Yue-Jia

    2015-07-01

    Recent findings have demonstrated that N170 adaptation effects evoked by face adaptors are general to face and non-face tests, implicating adaptor-locked interferences in the rapid adaptation paradigm. Here we examined the extent to which adaptor-locked interferences confound N170 adaptation effects in different experimental parameters by manipulating the stimulus onset asynchrony (SOA) duration and jitter between adaptors and tests. In the short SOA, those interferences were well visible for the grand-average ERP waveforms evoked by tests, and they are likely to render rapid adaptation paradigm with short SOA unreliable. The adaptor-locked interferences were attenuated by appropriately increasing SOA duration, such that face-sensitive adaptation effects were evident in the long SOA for both baseline-to-peak and peak-to-peak N170 measurements. These findings suggest that the rapid adaptation paradigm may work with a relative long SOA. Our findings provide useful information for future studies regarding the choosing of appropriate experimental parameters and measurements for the rapid adaptation paradigm. In addition, future studies are needed to investigate how to objectively subtract the overlaps of adaptors from tests and to validate the N170 adaptation effect with appropriate behavioral performance. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. [Development and evaluation of a rapid PCR detection kit for Ophiocordyceps sinensis].

    Science.gov (United States)

    Hou, Fei-Xia; Cao, Jing; Wang, Sha-Sha; Wang, Xi; Yuan, Yuan; Peng, Cheng; Wan, De-Guang; Guo, Jin-Lin

    2017-03-01

    Ophiocordyceps sinensis is a valuable traditional Chinese medicine. Due to resource shortage, expensive price and huge market demand, there are many adulterants of O. sinensis in markets. Therefore, it is necessary to establish a rapid and effective method for distinguishing O. sinensis. Based on the species-specific PCR of O. sinensis, this study developed a detection kit by optimizing the components and evaluated the specificity, detection limit, repeatability and shelf life of the kit. The results showed that when the quality of O. sinensis accounted for more than 1/200 of that mixture, it could be detected successfully. Moreover, only O. sinensis could be amplified and glowed bright green fluorescence under ultraviolet light. The kit was still in effect when it was placed at 37 ℃ for three days, which indicated that it was stable and effective for one year stored in 4 ℃. The kit in the same batch under different operation conditions, and in different batch under the same operation conditions gave the same result and accuracy, which showed good repeatability of the kit. It is simple, rapid and accurate to distinguish O. sinensis from its adulterants using the kit, and lays the foundation for commercialization of traditional Chinese medicine fast detection kit. Copyright© by the Chinese Pharmaceutical Association.

  17. Mobile Landing Platform with Core Capability Set (MLP w/CCS): Combined Initial Operational Test and Evaluation and Live Fire Test and Evaluation Report

    Science.gov (United States)

    2015-07-01

    SUBTITLE Mobile Landing Platform with Core Capability Set (MLP w/CCS) Combined Initial Operational Test and Evaluation ( IOT &E) and Live Fire Test and...based on data from a series of integrated test events, a dedicated end-to-end Initial Operational Test and Evaluation ( IOT &E), and two Marine Corps...Internally Transportable Vehicles (ITVs).   ii the LMSR to anchor within a few miles of the shore. Using MLP (CCS), the equipment is transported ashore

  18. Validation Study of Rapid Assays of Bioburden, Endotoxins and Other Contamination.

    Science.gov (United States)

    Shintani, Hideharu

    2016-01-01

    Microbial testing performed in support of pharmaceutical and biopharmaceutical production falls into three main categories: detection (qualitative), enumeration (quantitative), and characterization/identification. Traditional microbiological methods are listed in the compendia and discussed by using the conventional growth-based techniques, which are labor intensive and time consuming. In general, such tests require several days of incubation for microbial contamination (bioburden) to be detected, and therefore management seldom is able to take proactive corrective measures. In addition, microbial growth is limited by the growth medium used and incubation conditions, thus impacting testing sensitivity, accuracy, and reproducibility.  For more than 20 years various technology platforms for rapid microbiological methods (RMM) have been developed, and many have been readily adopted by the food industry and clinical microbiology laboratories. Their use would certainly offer drug companies faster test turnaround times to accommodate the aggressive deadlines for manufacturing processes and product release. Some rapid methods also offer the possibility for real-time microbial analyses, enabling management to respond to microbial contamination events in a more timely fashion, and can provide cost savings and higher efficiencies in quality control testing laboratories. Despite the many proven business and quality benefits and the fact that the FDA's initiative to promote the use of process analytical technology (PAT) includes rapid microbial methods, pharmaceutical and biopharmaceutical industries have been somewhat slow to embrace alternative microbial methodologies for several reasons. The major reason is that the bioburden counts detected by the incubation method and rapid assay are greatly divergent.  The use of rapid methods is a dynamic field in applied microbiology and one that has gained increased attention nationally and internationally over time. This topic

  19. Technical Evaluation of Oak Ridge Filter Test Facility

    CERN Document Server

    Kriskovich, J R

    2002-01-01

    Two evaluations of the Oak Ridge Department of Energy (DOE) Filter Test Facility (FTF) were performed on December 11 and 12, 2001, and consisted of a quality assurance and a technical evaluation. This report documents results of the technical evaluation.

  20. Comparative study of heuristic evaluation and usability testing methods.

    Science.gov (United States)

    Thyvalikakath, Thankam Paul; Monaco, Valerie; Thambuganipalle, Himabindu; Schleyer, Titus

    2009-01-01

    Usability methods, such as heuristic evaluation, cognitive walk-throughs and user testing, are increasingly used to evaluate and improve the design of clinical software applications. There is still some uncertainty, however, as to how those methods can be used to support the development process and evaluation in the most meaningful manner. In this study, we compared the results of a heuristic evaluation with those of formal user tests in order to determine which usability problems were detected by both methods. We conducted heuristic evaluation and usability testing on four major commercial dental computer-based patient records (CPRs), which together cover 80% of the market for chairside computer systems among general dentists. Both methods yielded strong evidence that the dental CPRs have significant usability problems. An average of 50% of empirically-determined usability problems were identified by the preceding heuristic evaluation. Some statements of heuristic violations were specific enough to precisely identify the actual usability problem that study participants encountered. Other violations were less specific, but still manifested themselves in usability problems and poor task outcomes. In this study, heuristic evaluation identified a significant portion of problems found during usability testing. While we make no assumptions about the generalizability of the results to other domains and software systems, heuristic evaluation may, under certain circumstances, be a useful tool to determine design problems early in the development cycle.

  1. Lateral Flow Rapid Test for Accurate and Early Diagnosis of Scrub Typhus: A Febrile Illness of Historically Military Importance in the Pacific Rim.

    Science.gov (United States)

    Chao, Chien-Chung; Zhangm, Zhiwen; Weissenberger, Giulia; Chen, Hua-Wei; Ching, Wei-Mei

    2017-03-01

    Scrub typhus (ST) is an infection caused by Orientia tsutsugamushi. Historically, ST was ranked as the second most important arthropod-borne medical problem only behind malaria during World War II and the Vietnam War. The disease occurs mainly in Southeast Asia and has been shown to emerge and reemerge in new areas, implying the increased risk for U.S. military and civilian personnel deployed to these regions. ST can effectively be treated by doxycycline provided the diagnosis is made early, before the development of severe complications. Scrub Typhus Detect is a lateral flow rapid test based on a mixture of recombinant 56-kDa antigens with broad reactivity. The performance of this prototype product was evaluated against indirect immunofluorescence assay, the serological gold standard. Using 249 prospectively collected samples from Thailand, the sensitivity and specificity for IgM was found to be 100% and 92%, respectively, suggesting a high potential of this product for clinical use. This product will provide a user friendly, rapid, and accurate diagnosis of ST for clinicians to provide timely and accurate treatments of deployed personnel. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  2. Rapid differentiation of Staphylococcus aureus, Staphylococcus epidermidis and other coagulase-negative staphylococci and meticillin susceptibility testing directly from growth-positive blood cultures by multiplex real-time PCR.

    Science.gov (United States)

    Jukes, Leanne; Mikhail, Jane; Bome-Mannathoko, Naledi; Hadfield, Stephen J; Harris, Llinos G; El-Bouri, Khalid; Davies, Angharad P; Mack, Dietrich

    2010-12-01

    This study evaluated a multiplex real-time PCR method specific for the mecA, femA-SA and femA-SE genes for rapid identification of Staphylococcus aureus, Staphylococcus epidermidis and non-S. epidermidis coagulase-negative staphylococci (CoNS), and meticillin susceptibility testing directly in positive blood cultures that grew Gram-positive cocci in clusters. A total of 100 positive blood cultures produced: 39 S. aureus [12 meticillin-resistant S. aureus (MRSA), 31% of all the S. aureus]; 30 S. epidermidis (56.6% of the CoNS), 8 Staphylococcus capitis (15.1%), 3 Staphylococcus saprophyticus (5.7%), 4 Staphylococcus hominis (7.5%), 3 Staphylococcus haemolyticus (5.7%), 2 Staphylococcus warneri (3.8%), 1 Staphylococcus cohnii (1.9%) and 2 unidentified Staphylococcus spp. (3.8%); and 1 Micrococcus luteus in pure culture. Two blood cultures had no growth on subculture and five blood cultures grew mixed CoNS. For the 95 blood cultures with pure growth or no growth on subculture, there was very good agreement between real-time PCR and the BD Phoenix identification system for staphylococcal species categorization in S. aureus, S. epidermidis and non-S. epidermidis CoNS and meticillin-resistance determination (Cohen's unweighted kappa coefficient κ=0.882). All MRSA and meticillin-susceptible S. aureus were correctly identified by mecA amplification. PCR amplification of mecA was more sensitive for direct detection of meticillin-resistant CoNS in positive blood cultures than testing with the BD Phoenix system. There were no major errors when identifying staphylococcal isolates and their meticillin susceptibility within 2.5 h. Further studies are needed to evaluate the clinical benefit of using such a rapid test on the consumption of glycopeptide antibiotics and the alteration of empiric therapy in the situation of positive blood cultures growing staphylococci, and the respective clinical outcomes.

  3. Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea

    Science.gov (United States)

    Kurosaki, Yohei; Magassouba, N’Faly; Oloniniyi, Olamide K.; Cherif, Mahamoud S.; Sakabe, Saori; Takada, Ayato; Hirayama, Kenji; Yasuda, Jiro

    2016-01-01

    Given the current absence of specific drugs or vaccines for Ebola virus disease (EVD), rapid, sensitive, and reliable diagnostic methods are required to stem the transmission chain of the disease. We have developed a rapid detection assay for Zaire ebolavirus based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and coupled with a novel portable isothermal amplification and detection platform. The RT-LAMP assay is based on primer sets that target the untranscribed trailer region or nucleoprotein coding region of the viral RNA. The test could specifically detect viral RNAs of Central and West African Ebola virus strains within 15 minutes with no cross-reactivity to other hemorrhagic fever viruses and arboviruses, which cause febrile disease. The assay was evaluated using a total of 100 clinical specimens (serum, n = 44; oral swab, n = 56) collected from suspected EVD cases in Guinea. The specificity of this diagnostic test was 100% for both primer sets, while the sensitivity was 100% and 97.9% for the trailer and nucleoprotein primer sets, respectively, compared with a reference standard RT-PCR test. These observations suggest that our diagnostic assay is useful for identifying EVD cases, especially in the field or in settings with insufficient infrastructure. PMID:26900929

  4. Comparison of amrad ICT test with microscopic examination for rapid diagnosis of malaria

    International Nuclear Information System (INIS)

    Rahim, F.; Amin-ul-Haq; Jamal, S.

    2002-01-01

    Objective: To assess the sensitivity and specificity of an alternate and easy technique to diagnose malaria. Design: A prospective study. Place and Duration of Study: Department of pathology, DHQ Hospital, Timergara District, Dir, North-west Frontier Province of Pakistan, from 19th September to 5th October 2000. Subjects and Methods: Smear positive 50 patients (27 males and 23 females, age ranging 2 years to 70 years) were included. Thick and thin smears were stained with Giemsa's stain and examined by the principal author. The ICT malaria test was performed according to the instruction sheet of the manufacturer. Results: on microscopy there were 29 cases of Plasmodium falciparum (P.f) and 21 of Plasmodiium vivax (P.v.). On ICT malaria P.f/P.v, there were 29 samples positive for P. Falciparum and 17 for P. vivax. These results demonstrated that the ICT malaria P.f/P.v test had sensitivity of 100% for P. falciparum and 81% for P. vivax and specificity of 100% for both, when compared to traditional blood films for the detection of P. vivax and P. falciparum malaria. Conclusion: The ICT malaria P.f/P.v test is an effective tool for the rapid diagnosis of malaria and may be used as a first line diagnostic tool. (author)

  5. Fabrication and tensile properties of rapidly solidified Cu-10wt. %Ni alloy. [Cu-10Ni

    Energy Technology Data Exchange (ETDEWEB)

    Baril, D; Angers, R; Baril, J [Dept. of Mining and Metallurgy, Laval Univ., Ste-Foy, Quebec (Canada)

    1992-10-15

    Cu-10wt.%Ni ribbons were produced by melt spinning and cut into small particles with a blade cutter mill. The powders were then hot consolidated to full density by hot pressing followed by hot extrusion. Tensile properties of the resulting pieces were measured. Cu-10wt.%Ni cast ingots were also hot extruded and mechanically tested to compare with the rapidly solidified alloy and to evaluate the possible benefits brought by the rapid solidification process.

  6. Evaluation of antimicrobial activity of selected plant extracts by rapid XTT colorimetry and bacterial enumeration.

    Science.gov (United States)

    Al-Bakri, Amal G; Afifi, Fatma U

    2007-01-01

    The aim of this study was to screen and evaluate the antimicrobial activity of indigenous Jordanian plant extracts, dissolved in dimethylsulfoxide, using the rapid XTT assay and viable count methods. XTT rapid assay was used for the initial screening of antimicrobial activity for the plant extracts. Antimicrobial activity of potentially active plant extracts was further assessed using the "viable plate count" method. Four degrees of antimicrobial activity (high, moderate, weak and inactive) against Bacillus subtilis, Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa, respectively, were recorded. The plant extracts of Hypericum triquetrifolium, Ballota undulata, Ruta chalepensis, Ononis natrix, Paronychia argentea and Marrubium vulgare had shown promising antimicrobial activity. This study showed that while both XTT and viable count methods are comparable when estimating the overall antimicrobial activity of experimental substances, there is no strong linear correlation between the two methods.

  7. CARES (Computer Analysis for Rapid Evaluation of Structures) Version 1.0, seismic module

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulas, A.J.; Miller, C.A.; Costantino, C.J.

    1990-07-01

    During FY's 1988 and 1989, Brookhaven National Laboratory (BNL) developed the CARES system (Computer Analysis for Rapid Evaluation of Structures) for the US Nuclear Regulatory Commission (NRC). CARES is a PC software system which has been designed to perform structural response computations similar to those encountered in licensing reviews of nuclear power plant structures. The documentation of the Seismic Module of CARES consists of three volumes. This report represents Volume 3 of the volume documentation of the Seismic Module of CARES. It presents three sample problems typically encountered in the Soil-Structure Interaction analyses. 14 refs., 36 figs., 2 tabs

  8. The advanced test reactor strategic evaluation program

    International Nuclear Information System (INIS)

    Buescher, B.J.

    1989-01-01

    Since the Chernobly accident, the safety of test reactors and irradiation facilities has been critically evaluated from the public's point of view. A systematic evaluation of all safety, environmental, and operational issues must be made in an integrated manner to prioritize actions to maximize benefits while minimizing costs. Such a proactive program has been initiated at the Advanced Test Reactor (ATR). This program, called the Strategic Evaluation Program (STEP), is being conducted for the ATR to provide integrated safety and operational reviews of the reactor against the standards applied to licensed commercial power reactors. This has taken into consideration the lessons learned by the US Nuclear Regulatory Commission (NRC) in its Systematic Evaluation Program (SEP) and the follow-on effort known as the Integrated Safety Assessment Program (ISAP). The SEP was initiated by the NRC to review the designs of older operating nuclear power plants to confirm and document their safety. The ATR STEP objectives are discussed

  9. Framework for a National Testing and Evaluation Program ...

    Science.gov (United States)

    Abstract:The National STEPP Program seeks to improve water quality by accelerating the effective implementation and adoption of innovative stormwater management technologies. Itwill attempt to accomplish this by establishing practices through highly reliable, and cost-effective Stormwater control measures (SCM) testing, evaluation, and verification services. The program will aim to remove barriers to innovation, minimize duplicative performance evaluation needs, increase confidence that regulatory requirements are met by creating consistency among testing and evaluation protocols, and establishing equity between public domain and proprietary SCM evaluation approaches.The Environmental Technology Verification Program, established by the U.S. Environmental Protection Agency (EPA) 18 years ago, was the only national program of its kindin the stormwater sector, but is now defunct, leaving a national leadership void. The STEPP initiative was triggered in part by regulatory demands in the government and private sectors to fill this vacuum. A concerted focus and study of this matter led to the release of a Water Environment Federation (WEF) white paper entitled “Investigation into the Feasibility of a National Testing and Evaluation Program for Stormwater Products and Practices” in February 2014. During this second phase of the STEPP initiative, and with EPA support, five analogous technology evaluation programs related to both stormwater and non-stormwater were an

  10. G-tunnel pressurized slot-testing evaluations

    International Nuclear Information System (INIS)

    Zimmerman, R.M.; Sifre-Soto, C.; Mann, K.L.; Bellman, R.A. Jr.; Luker, S.; Dodds, D.J.

    1992-04-01

    Designers and analysts of radioactive waste repositories must be able to predict the mechanical behavior of the host rock. Sandia National Laboratories elected to conduct a development program to enhance mechanical-type measurements. The program was focused on pressurized slot testing and featured (1) development of an improved method to cut slots using a chain saw with diamond-tipped cutters, (2) measurements useful for determining in situ stresses normal to slots, (3) measurements applicable for determining the in situ modulus of deformation parallel to a drift surface, and (4) evaluations of pressurized slot strength testing results and methods. This report contains data interpretation and evaluations. Included are recommendations for future efforts. This third report contains the interpretations of the testing with emphasis on the measurement results as they apply to describing rock behavior. In particular, emphases are placed on (1) normal stress determinations using the flatjack cancellation (FC) method, (2) modulus of deformation determinations, and (3) high pressure investigations. Most of the material in the first two reports is not repeated here. Appropriate data are repeated in tabular form

  11. Economic impact of rapid diagnostic methods in Clinical Microbiology: Price of the test or overall clinical impact.

    Science.gov (United States)

    Cantón, Rafael; Gómez G de la Pedrosa, Elia

    2017-12-01

    The need to reduce the time it takes to establish a microbiological diagnosis and the emergence of new molecular microbiology and proteomic technologies has fuelled the development of rapid and point-of-care techniques, as well as the so-called point-of-care laboratories. These laboratories are responsible for conducting both techniques partially to response to the outsourcing of the conventional hospital laboratories. Their introduction has not always been accompanied with economic studies that address their cost-effectiveness, cost-benefit and cost-utility, but rather tend to be limited to the unit price of the test. The latter, influenced by the purchase procedure, does not usually have a regulated reference value in the same way that medicines do. The cost-effectiveness studies that have recently been conducted on mass spectrometry in the diagnosis of bacteraemia and the use of antimicrobials have had the greatest clinical impact and may act as a model for future economic studies on rapid and point-of-care tests. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  12. Cost-effectiveness of malaria microscopy and rapid diagnostic tests versus presumptive diagnosis

    DEFF Research Database (Denmark)

    Batwala, Vincent; Magnussen, Pascal; Hansen, Kristian Schultz

    2011-01-01

    .9) than in low transmission setting (US$1.78). At a willingness to pay of US$2.8, RDT remained cost effective up to a threshold value of the cost of treatment of US$4.7. CONCLUSION: RDT was cost effective in both low and high transmission settings. With a global campaign to reduce the costs of AL and RDT......ABSTRACT: BACKGROUND: Current Uganda National Malaria treatment guidelines recommend parasitological confirmation either by microscopy or rapid diagnostic test (RDT) before treatment with artemether-lumefantrine (AL). However, the cost-effectiveness of these strategies has not been assessed...... departments were enrolled from March 2010 to February 2011. Of these, a random sample of 1,627 was selected to measure additional socio-economic characteristics. Costing was performed following the standard step-down cost allocation and the ingredients approach. Effectiveness was measured as the number...

  13. Rapid and point-of-care tests for the diagnosis of Trichomonas vaginalis in women and men.

    Science.gov (United States)

    Gaydos, Charlotte A; Klausner, Jeffrey D; Pai, Nitika Pant; Kelly, Helen; Coltart, Cordelia; Peeling, Rosanna W

    2017-12-01

    Trichomonasvaginalis (TV) is a highly prevalent parasitic infection worldwide. It is associated with many adverse reproductive health outcomes. Many infections are asymptomatic and syndromic management leads to underdetection of TV. Traditional methods of TV detection such as wet preparation are insensitive. New rapid, point-of-care (POC) tests can enhance the diagnosis of trichomoniasis. The authors reviewed the literature and discuss older POC tests for TV detection, as well as the OSOM lateral flow test, the AmpliVue test, the Solana test and the GeneXpert test as well as the limitations of wet preparation and culture for detection of TV. The OSOM test is easy to perform, compared with other POC tests, and is Clinical Laboratory Improvement Amendments (CLIA)-waived, equipment-free, has sensitivities of 83%-86% compared with nucleic acid amplification tests (NAATs) and can be performed in 15 min. The AmpliVue and the Solana tests are not CLIA waived and require small pieces of equipment. They are molecular amplified assays and can be completed in TV test for women and men is a moderately complex test, requires a small platform and can be performed in women and one is available for detection of TV in men. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Rapid diagnosis of retina and optic nerve abnormalities in canine patients with and without cataracts using chromatic pupil light reflex testing.

    Science.gov (United States)

    Grozdanic, Sinisa D; Kecova, Helga; Lazic, Tatjana

    2013-09-01

    To develop fast and reliable testing routines for diagnosing retina and optic nerve diseases in canine cataract patients based on chromatic properties of the pupillary light reflex response. Seventy-seven canine patients with a history of cataract and decreased vision (43 patients with cataracts and no evidence of retina or optic nerve disease, 21 patients with cataracts and retinal degeneration [RD], 13 patients with cataracts and retinal detachment [RDT]), 11 canine patients with optic neuritis (ON) and 23 healthy dogs were examined using chromatic pupillary light reflex (cPLR) analysis with red and blue light and electroretinography. Electroretinography analysis showed statistically significant deficits in a- and b-wave amplitudes in dogs with cataracts and RD, or cataracts and RDT, when compared to dogs with cataracts without evidence of retinal abnormalities. Evaluation of b-wave amplitudes showed that presence of 78.5-μV (or lower) amplitudes had high sensitivity of 100% (95% CI: 87.2-100%) and high specificity of 96.7% (95% CI: 88.4-100%) in RD and RDT. Evaluation of cPLR responses using red light showed that presence of the pupil end constriction diameter of 5.5 mm (or higher) had moderately high sensitivity of 76.5% (95% CI: 50.1-93.2%) and high specificity of 100% (95% CI: 91.2-100%) in detecting RD and RDT. Optic neuritis patients had absent cPLR responses, regardless of the visual status. Chromatic evaluation of the pupillary light reflex is a rapid and accurate test for diagnosing retina and optic nerve diseases in canine patients. © 2012 American College of Veterinary Ophthalmologists.

  15. Portable Diagnostics and Rapid Germination

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Zachary Spencer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

  16. CUSUM-Logistic Regression analysis for the rapid detection of errors in clinical laboratory test results.

    Science.gov (United States)

    Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T

    2016-02-01

    The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.

  17. A Rapid Blood Test To Determine the Active Status and Duration of Acute Viral Infection.

    Science.gov (United States)

    Zheng, Tianyu; Finn, Caroline; Parrett, Christopher J; Dhume, Kunal; Hwang, Ji Hae; Sidhom, David; Strutt, Tara M; Li Sip, Yuen Yee; McKinstry, Karl K; Huo, Qun

    2017-11-10

    The ability to rapidly detect and diagnose acute viral infections is crucial for infectious disease control and management. Serology testing for the presence of virus-elicited antibodies in blood is one of the methods used commonly for clinical diagnosis of viral infections. However, standard serology-based tests have a significant limitation: they cannot easily distinguish active from past, historical infections. As a result, it is difficult to determine whether a patient is currently infected with a virus or not, and on an optimal course of action, based off of positive serology testing responses. Here, we report a nanoparticle-enabled blood test that can help overcome this major challenge. The new test is based on the analysis of virus-elicited immunoglobulin G (IgG) antibody present in the protein corona of a gold nanoparticle surface upon mixing the gold nanoparticles with blood sera. Studies conducted on mouse models of influenza A virus infection show that the test gives positive responses only in the presence of a recent acute viral infection, approximately between day 14 and day 21 following the infection, and becomes negative thereafter. When used together with the traditional serology testing, the nanoparticle test can determine clearly whether a positive serology response is due to a recent or historical viral infection. This new blood test can provide critical clinical information needed to optimize further treatment and/or to determine if further quarantining should be continued.

  18. Observer and biological variation of a rapid whole blood D-dimer test

    NARCIS (Netherlands)

    Turkstra, F.; van Beek, E. J.; Büller, H. R.

    1998-01-01

    In consecutive patients with suspected venous thromboembolism the interobserver variability of the SimpliRED D-dimer test was evaluated by two observers who independently scored one plate, the between assay variation was performed simultaneously by a third independent observer, who assessed a second

  19. Rapid Evaluation Capability (REC)

    Data.gov (United States)

    Federal Laboratory Consortium — The REC, located at Camp Grayling, MI, uses the only high-explosive impact area in the state to conduct year-round experiments and evaluations. In coordination with...

  20. A longitudinal evaluation of Treponema pallidum PCR testing in early syphilis

    Directory of Open Access Journals (Sweden)

    Shields Matt

    2012-12-01

    Full Text Available Abstract Background Syphilis is a growing public health problem among men who have sex with men (MSM globally. Rapid and accurate detection of syphilis is vital to ensure patients and their contacts receive timely treatment and reduce ongoing transmission. Methods We evaluated a PCR assay for the diagnosis of Treponema pallidum using swabs of suspected early syphilis lesions in longitudinally assessed MSM. Results We tested 260 MSM for T pallidum by PCR on 288 occasions: 77 (26.7% had early syphilis that was serologically confirmed at baseline or within six weeks, and 211 (73.3% remained seronegative for syphilis. Of 55 men with primary syphilis, 49 were PCR positive, giving a sensitivity of 89.1% (95% CI: 77.8%-95.9% and a specificity of 99.1% (95% CI: 96.5%-99.9%. Of 22 men with secondary syphilis, 11 were PCR positive, giving a sensitivity of 50% (95% CI: 28.2%-71.8% and a specificity of 100% (95% CI: 66.4%-71.8%. Of the 77 syphilis cases, 43 (56% were HIV positive and the sensitivity and specificity of the PCR test did not vary by HIV status. The PCR test was able to detect up to five (10% primary infections that were initially seronegative, including one HIV positive man with delayed seroconversion to syphilis (72 to 140 days and one HIV positive man who did not seroconvert to syphilis over 14 months follow-up. Both men had been treated for syphilis within a week of the PCR test. Conclusions T pallidum PCR is a potentially powerful tool for the early diagnosis of primary syphilis, particularly where a serological response has yet to develop.