WorldWideScience

Sample records for rapid radiometric method

  1. Radiometric method for the rapid detection of Leptospira organisms

    International Nuclear Information System (INIS)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-01-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with 14 C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques

  2. Radiometric method for the rapid detection of Leptospira organisms

    Energy Technology Data Exchange (ETDEWEB)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-02-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with /sup 14/C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques.

  3. Rapid radiometric method for detection of Salmonella in foods

    International Nuclear Information System (INIS)

    Stewart, B.J.; Eyles, M.J.; Murrell, W.G.

    1980-01-01

    A radiometric method for the detection of Salmonella in foods has been developed which is based on Salmonella poly H agglutinating serum preventing Salmonella from producing 14CO2 from [14C] dulcitol. The method will detect the presence or absence of Salmonella in a product within 30 h compared to 4 to 5 days by routine culture methods. The method has been evaluated against a routine culture method using 58 samples of food. The overall agreement was 91%. Five samples negative for Salmonella by the routine method were positive by the radiometric method. These may have been false positives. However, the routine method may have failed to detect Salmonella due to the presence of large numbers of lactose-fermenting bacteria which hindered isolation of Salmonella colonies on the selective agar plates

  4. Evaluation of rapid radiometric method for drug susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Libonati, J.P.; Middlebrook, G.

    1981-01-01

    A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with 14 C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests results reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations

  5. Rapid radiometric methods to detect and differentiate Mycobacterium tuberculosis/M. bovis from other mycobacterial species

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Hwangbo, C.C.; Silcox, V.; Good, R.C.; Snider, D.E. Jr.; Middlebrook, G.

    1984-01-01

    Rapid methods for the differentiation of Mycobacterium tuberculosis/M. bovis (TB complex) from other mycobacteria (MOTT bacilli) were developed and evaluated in a three-phase study. In the first phase, techniques for identification of Mycobacterium species were developed by using radiometric technology and BACTEC Middlebrook 7H12 liquid medium. Based on 14 CO 2 evolution, characteristic growth patterns were established for 13 commonly encountered mycobacterial species. Mycobacteria belonging to the TB complex were differentiated from other mycobacteria by cellular morphology and rate of 14 CO 2 evolution. For further differentiation, radiometric tests for niacin production and inhibition by Q-nitro-alpha-acetyl amino-beta-hydroxy-propiophenone (NAP) were developed. In the second phase, 100 coded specimens on Lowenstein-Jensen medium were identified as members of the TB complex, MOTT bacilli, bacteria other than mycobacteria, or ''no viable organisms'' within 3 to 12 (average 6.4) days of receipt from the Centers for Disease Control. Isolation and identification of mycobacteria from 20 simulated sputum specimens were carried out in phase III. Out of 20 sputum specimens, 16 contained culturable mycobacteria, and all of the positives were detected by the BACTEC method in an average of 7.3 days. The positive mycobacterial cultures were isolated and identified as TB complex or MOTT bacilli in an average of 12.8 days. The radiometric NAP test was found to be highly sensitive and specific for a rapid identification of TB complex, whereas the radiometric niacin test was found to have some inherent problems. Radiometric BACTEC and conventional methodologies were in complete agreement in Phase II as well as in Phase III

  6. Rapid detection and identification of pathogenic mycobacteria by combining radiometric and nucleic acid probe methods

    International Nuclear Information System (INIS)

    Ellner, P.D.; Kiehn, T.E.; Cammarata, R.; Hosmer, M.

    1988-01-01

    The combination of radiometric methodology (BACTEC 12B) and probe technology for recovery and identification of mycobacteria was studied in two large hospital laboratories. The sediment from vials with positive growth indices was tested with DNA probes specific for Mycobacterium tuberculosis, Mycobacterium avium, and Mycobacterium intracellulare. The sensitivity of the radiometric method and the specificity of the probes resulted in a marked reduction in the time to the final report. Biochemical testing could be eliminated on isolates giving a positive reaction with one of the probes. Some 176 isolates of M. tuberculosis, 110 of M. avium, and 5 of M. intracellulare were recovered. Two-thirds of these isolates were detected and identified within 2 weeks of inoculation and the remainder was detected by 4 weeks, a reduction of 5 to 7 weeks to the final report

  7. Substoichiometric method in the simple radiometric analysis

    International Nuclear Information System (INIS)

    Ikeda, N.; Noguchi, K.

    1979-01-01

    The substoichiometric method is applied to simple radiometric analysis. Two methods - the standard reagent method and the standard sample method - are proposed. The validity of the principle of the methods is verified experimentally in the determination of silver by the precipitation method, or of zinc by the ion-exchange or solvent-extraction method. The proposed methods are simple and rapid compared with the conventional superstoichiometric method. (author)

  8. Radiometric dating methods

    International Nuclear Information System (INIS)

    Bourdon, B.

    2003-01-01

    The general principle of isotope dating methods is based on the presence of radioactive isotopes in the geologic or archaeological object to be dated. The decay with time of these isotopes is used to determine the 'zero' time corresponding to the event to be dated. This paper recalls the general principle of isotope dating methods (bases, analytical methods, validation of results and uncertainties) and presents the methods based on natural radioactivity (Rb-Sr, Sm-Nd, U-Pb, Re-Os, K-Ar (Ar-Ar), U-Th-Ra- 210 Pb, U-Pa, 14 C, 36 Cl, 10 Be) and the methods based on artificial radioactivity with their applications. Finally, the methods based on irradiation damages (thermoluminescence, fission tracks, electron spin resonance) are briefly evoked. (J.S.)

  9. RapidEye constellation relative radiometric accuracy measurement using lunar images

    Science.gov (United States)

    Steyn, Joe; Tyc, George; Beckett, Keith; Hashida, Yoshi

    2009-09-01

    The RapidEye constellation includes five identical satellites in Low Earth Orbit (LEO). Each satellite has a 5-band (blue, green, red, red-edge and near infrared (NIR)) multispectral imager at 6.5m GSD. A three-axes attitude control system allows pointing the imager of each satellite at the Moon during lunations. It is therefore possible to image the Moon from near identical viewing geometry within a span of 80 minutes with each one of the imagers. Comparing the radiometrically corrected images obtained from each band and each satellite allows a near instantaneous relative radiometric accuracy measurement and determination of relative gain changes between the five imagers. A more traditional terrestrial vicarious radiometric calibration program has also been completed by MDA on RapidEye. The two components of this program provide for spatial radiometric calibration ensuring that detector-to-detector response remains flat, while a temporal radiometric calibration approach has accumulated images of specific dry dessert calibration sites. These images are used to measure the constellation relative radiometric response and make on-ground gain and offset adjustments in order to maintain the relative accuracy of the constellation within +/-2.5%. A quantitative comparison between the gain changes measured by the lunar method and the terrestrial temporal radiometric calibration method is performed and will be presented.

  10. Radiometric measuring method for egg shells

    Energy Technology Data Exchange (ETDEWEB)

    Forberg, S; Svaerdstroem, K

    1973-02-01

    A description is given of a fast nondestructive radiometric method for registration of the thickness of egg shells of the tawny owl, hen, osprey, and Canada goose. Certain errors are discussed. Measurement of the thickness of egg shells (mineral content per cm/sup 2/) with an accuracy better than 1% is possible in less than one minute under field conditions. (auth)

  11. Characterization of Mycobacterium paratuberculosis by gas-liquid and thin-layer chromatography and rapid demonstration of mycobactin dependence using radiometric methods

    International Nuclear Information System (INIS)

    Damato, J.J.; Knisley, C.; Collins, M.T.

    1987-01-01

    Thirty-six Mycobacterium paratuberculosis isolates of bovine, caprine, and ovine origins were evaluated by using gas-liquid chromatography (GLC), thin-layer chromatography (TLC), and BACTEC 7H12 Middlebrook TB medium in an effort to more rapidly differentiate this group of organisms from other mycobacteria. Bacterial suspensions (0.1 ml) were inoculated by syringe into 7H12 broth containing 2 micrograms of mycobactin P per ml and control broth without mycobactin P. Cultures were incubated at 37 0 C and read daily with a BACTEC Model 301. After 8 days of incubation, the growth index readings for the test broths containing mycobactin P were twice those of the control broths without mycobactin P. Sixty-five isolates of mycobacteria other than M. paratuberculosis were also examined. No difference was noted between the growth index readings of control and mycobactin-containing broths. Except for Mycobacterium avium-Mycobacterium intracellulare, TLC studies differentiated M. paratuberculosis from the other mycobacterial species tested. The GLC data reveal that all M. paratuberculosis isolates had a distinctive peak (14A) which was not found among M. avium-M. intracellulare complex organisms. These data indicate that 7H12 radiometric broth was able to rapidly demonstrate the mycobactin dependence of M. paratuberculosis and GLC and TLC procedures were capable of rapidly differentiating this organism from the other mycobacteria studied

  12. Field radiometric methods of prospecting and exploration for uranium ores

    International Nuclear Information System (INIS)

    Gorbushina, L.V.; Savenko, E.I.; Serdyukova, A.S.

    1978-01-01

    The textbook includes two main chapters which describe gamma- and emanation field radiometric methods. The textbook is intended for geology and geophysics students having training practice in field radiometric methods and is additional to the course of lectures. The textbook can be used in the''Radiometry'' course which is studied in appropriate geological and technical colleges

  13. Evaluation of a radiometric method for studying bacterial activity in the presence of antimicrobial agents

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, R.R.; Wilson, P.; Clarke, F.V. (Newham District Microbiology Labs., St. Andrews Hospital, London (UK))

    1989-06-01

    In a study involving 2760 tests, the BACTEC semi-automatic radiometric method which measures bacterial metabolic activity and produces a BACTEC growth index, was compared with two conventional methods commonly used for determining growth, absorbance and viable counts. In 92% of radiometry tests the suppression of growth was inversely related to the antibiotic concentration. This compared with 83% for absorbance and 63% for viable counts. The radiometric method was found to be more rapid, easier to use and more reproducible in determining the effect of antibiotics on the activity of bacteria than viable counting or absorbance methods. (author).

  14. Evaluation of a radiometric method for studying bacterial activity in the presence of antimicrobial agents

    International Nuclear Information System (INIS)

    Cutler, R.R.; Wilson, P.; Clarke, F.V.

    1989-01-01

    In a study involving 2760 tests, the BACTEC semi-automatic radiometric method which measures bacterial metabolic activity and produces a BACTEC growth index, was compared with two conventional methods commonly used for determining growth, absorbance and viable counts. In 92% of radiometry tests the suppression of growth was inversely related to the antibiotic concentration. This compared with 83% for absorbance and 63% for viable counts. The radiometric method was found to be more rapid, easier to use and more reproducible in determining the effect of antibiotics on the activity of bacteria than viable counting or absorbance methods. (author)

  15. Determination of in vitro susceptibility of Mycobacterium tuberculosis to cephalosporins by radiometric and conventional methods

    International Nuclear Information System (INIS)

    Heifets, L.B.; Iseman, M.D.; Cook, J.L.; Lindholm-Levy, P.J.; Drupa, I.

    1985-01-01

    Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlation among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis

  16. Method and apparatus for enhancing radiometric imaging

    International Nuclear Information System (INIS)

    Logan, R. H.; Paradish, F. J.

    1985-01-01

    Disclosed is a method and apparatus for enhancing target detection, particularly in the millimeter wave frequency range, through the utilization of an imaging radiometer. The radiometer, which is a passive thermal receiver, detects the reflected and emitted thermal radiation of targets within a predetermined antenna/receiver beamwidth. By scanning the radiometer over a target area, a thermal image is created. At millimeter wave frequencies, the received emissions from the target area are highly dependent on the emissivity of the target of interest. Foliage will appear ''hot'' due to its high emissivity and metals will appear cold due to their low emissivities. A noise power illuminator is periodically actuated to illuminate the target of interest. When the illuminator is actuated, the role of emissivity is reversed, namely poorly emissive targets will generally be good reflectors which in the presence of an illuminator will appear ''hot''. The highly emissive targets (such as foliage and dirt) which absorb most of the transmitted energy will appear almost the same as in a nonilluminated, passive image. Using a data processor, the intensity of the passive image is subtracted from the intensity of the illuminated, active image which thereby cancels the background foliage, dirt, etc. and the reflective metallic targets are enhanced

  17. Radiometric titration of diethanolamine with 65ZnSO4 and determination of mono and diethanolamines in a mixture by a radiometric method

    International Nuclear Information System (INIS)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S.

    1984-01-01

    Radiometric titration of diethanolamine with 65 ZnSO 4 is reported. Determination of individual amounts of mono- and diethanolamines in a mixture is described. The procedure is simple, rapid and accurate. (author)

  18. Radiometric titration of diethanolamine with /sup 65/ZnSO/sub 4/ and determination of mono and diethanolamines in a mixture by a radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S. (Indian Inst. of Tech., Madras. Dept. of Chemistry)

    1984-08-16

    Radiometric titration of diethanolamine with /sup 65/ZnSO/sub 4/ is reported. Determination of individual amounts of mono- and diethanolamines in a mixture is described. The procedure is simple, rapid and accurate.

  19. Radiometric and geometric assessment of data from the RapidEye constellation of satellites

    Science.gov (United States)

    Chander, Gyanesh; Haque, Md. Obaidul; Sampath, Aparajithan; Brunn, A.; Trosset, G.; Hoffmann, D.; Roloff, S.; Thiele, M.; Anderson, C.

    2013-01-01

    To monitor land surface processes over a wide range of temporal and spatial scales, it is critical to have coordinated observations of the Earth's surface using imagery acquired from multiple spaceborne imaging sensors. The RapidEye (RE) satellite constellation acquires high-resolution satellite images covering the entire globe within a very short period of time by sensors identical in construction and cross-calibrated to each other. To evaluate the RE high-resolution Multi-spectral Imager (MSI) sensor capabilities, a cross-comparison between the RE constellation of sensors was performed first using image statistics based on large common areas observed over pseudo-invariant calibration sites (PICS) by the sensors and, second, by comparing the on-orbit radiometric calibration temporal trending over a large number of calibration sites. For any spectral band, the individual responses measured by the five satellites of the RE constellation were found to differ B2B) alignment of the image data sets. The position accuracy was assessed by comparing the RE imagery against high-resolution aerial imagery, while the B2B characterization was performed by registering each band against every other band to ensure that the proper band alignment is provided for an image product. The B2B results indicate that the internal alignments of these five RE bands are in agreement, with bands typically registered to within 0.25 pixels of each other or better.

  20. Basing of principles and methods of operation of radiometric control and measurement systems

    International Nuclear Information System (INIS)

    Onishchenko, A.M.

    1995-01-01

    Six basic stages of optimization of radiometric systems, methods of defining the preset components of total error and the choice of principles and methods of measurement are described in succession. The possibility of simultaneous optimization of several stages, turning back to the already passed stages, is shown. It is suggested that components of the total error should be preset as identical ones for methodical, instrument, occasional and representativity errors and the greatest of the components should be decreased first of all. Comparative table for 64 radiometric methods of measurement by 11 indices of the methods quality is presented. 2 refs., 1 tab

  1. A practical intercomparison of non-radiometric methods for the determination of low levels of radionuclides

    International Nuclear Information System (INIS)

    McMahon, A.W.

    1991-01-01

    Non-Radiometric, methods of elemental analysis have been assessed as alternatives to radiometric methods for the determination of low levels of radionuclides. The methods have been assessed in a practical intercomparison, using a set of samples containing known, low levels of analytes in a variety of matrices. It was found that all of the methods considered have a role to play and are to some extent complementary in terms of cost, rate of sample throughput, elemental coverage, imaging capability sensitivity and quantitative capabilities. Techniques based on mass spectrometry have most to offer in this application, allowing sensitive isotope specific determinations. (author)

  2. A method of automatic data processing in radiometric control

    International Nuclear Information System (INIS)

    Adonin, V.M.; Gulyukina, N.A.; Nemirov, Yu.V.; Mogil'nitskij, M.I.

    1980-01-01

    Described is the algorithm for automatic data processing in gamma radiography of products. Rapidity due to application of recurrent evaluation is a specific feature of the processing. Experimental data of by-line control are presented. The results obtained have shown the applicability of automatic signal processing to the testing under industrial conditions, which would permit to increase the testing efficiency to eliminate the subjectivism in assessment of testing results and to improve working conditions

  3. An equivalent method of mixed dielectric constant in passive microwave/millimeter radiometric measurement

    Science.gov (United States)

    Su, Jinlong; Tian, Yan; Hu, Fei; Gui, Liangqi; Cheng, Yayun; Peng, Xiaohui

    2017-10-01

    Dielectric constant is an important role to describe the properties of matter. This paper proposes This paper proposes the concept of mixed dielectric constant(MDC) in passive microwave radiometric measurement. In addition, a MDC inversion method is come up, Ratio of Angle-Polarization Difference(RAPD) is utilized in this method. The MDC of several materials are investigated using RAPD. Brightness temperatures(TBs) which calculated by MDC and original dielectric constant are compared. Random errors are added to the simulation to test the robustness of the algorithm. Keywords: Passive detection, microwave/millimeter, radiometric measurement, ratio of angle-polarization difference (RAPD), mixed dielectric constant (MDC), brightness temperatures, remote sensing, target recognition.

  4. Evaluation of element migration from food plastic packagings into simulated solutions using radiometric method

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez; Saiki, Mitiko; Wiebeck, Helio

    2005-01-01

    In the present study a radiometric method was established to determine the migration of elements from food plastic packagings to a simulated acetic acid solution. This radiometric method consisted of irradiating plastic samples with neutrons at IEA-R1 nuclear reactor for a period of 16 hours under a neutron flux of 10 12 n cm -2 s -1 and, then to expose them to the element migration into a simulated solution. The radioactivity of the activated elements transferred to the solutions was measured to evaluate the migration. The experimental conditions were: time of exposure of 10 days at 40 deg C and 3% acetic acid solution was used as simulated solution, according to the procedure established by the National Agency of Sanitary Monitoring (ANVISA). The migration study was applied for plastic samples from soft drink and juice packagings. The results obtained indicated the migration of elements Co, Cr and Sb. The advantage of this methodology was no need to analyse the blank of simulantes, as well as the use of high purity simulated solutions. Besides, the method allows to evaluate the migration of the elements into the food content instead of simulated solution. The detention limits indicated high sensitivity of the radiometric method. (author)

  5. A radiometric method for the characterization of particulate processes in colloidal suspensions. II

    International Nuclear Information System (INIS)

    Subotic, B.

    1979-01-01

    A radiometric method for the characterization of particulate processes is verified using stable hydrosols of silver iodide. Silver iodide hydrosols satisfy the conditions required for the applications of the proposed method. Comparison shows that the values for the change of particle size measured in silver iodide hydrosols by the proposed method are in excellent agreement with the values obtained by other methods on the same systems (electron microscopy, sedimentation analysis, light scattering). This shows that the proposed method is suitable for the characterization of particulate processes in colloidal suspensions. (Auth.

  6. Development of radiometric methods for radioactive waste characterization

    International Nuclear Information System (INIS)

    Tessaro, Ana Paula Gimenes

    2015-01-01

    The admission of radioactive waste in a final repository depends among other things on the knowledge of the radioisotopic inventory of the waste. To obtain this information it is necessary make the primary characterization of the waste so that it is composition is known, to guide the next steps of radioactive waste management. Filter cartridges that are used in the water polishing system of IEA-R1 research reactor is one of these wastes. The IEA-R1 is a pool-type research reactor, operating between 2 and 5 MW that uses water as coolant, moderator and biological shield. Besides research, it is used for production of radioisotopes and irradiation of samples with neutron and gamma beams. It is located in the Nuclear and Energy Research Institute at the University of Sao Paulo campus. The filter cartridges are used to retain particles that are suspended in the cooling water. When filters become saturated and are unable to maintain the flow within the established limits, they are replaced and disposed of as radioactive waste. After a period of decay, they are sent to the Radioactive Waste Management Department. The aim of this work is to present the studies to determine the activity of gamma emitters present in the cartridge filters. The activities were calculated using the dose rates measured with hand held detectors, after the ratios of the emission rates of photons were evaluated by gamma spectrometry, by the Point Kernel method, which correlates the activity of a source with dose rates at various distances. The method described can be used to determine routinely the radioactive inventory of these filters, avoiding the necessity of destructive radiochemical analysis, or the necessity of calibrating the geometry of measurement. (author)

  7. Radiometric Cross-Calibration of the Chilean Satellite FASat-C Using RapidEye and EO-1 Hyperion Data and a Simultaneous Nadir Overpass Approach

    Directory of Open Access Journals (Sweden)

    Carolina Barrientos

    2016-07-01

    Full Text Available The absolute radiometric calibration of a satellite sensor is the critical factor that ensures the usefulness of the acquired data for quantitative applications on remote sensing. This work presents the results of the first cross-calibration of the sensor on board the Sistema Satelital de Observación de la Tierra (SSOT Chilean satellite or Air Force Satellite FASat-C. RapidEye-MSI was chosen as the reference sensor, and a simultaneous Nadir Overpass Approach (SNO was applied. The biases caused by differences in the spectral responses of both instruments were compensated through an adjustment factor derived from EO-1 Hyperion data. Through this method, the variations affecting the radiometric response of New AstroSat Optical Modular Instrument (NAOMI-1, have been corrected based on collections over the Frenchman Flat calibration site. The results of a preliminary evaluation of the pre-flight and updated coefficients have shown a significant improvement in the accuracy of at-sensor radiances and TOA reflectances: an average agreement of 2.63% (RMSE was achieved for the multispectral bands of both instruments. This research will provide a basis for the continuity of calibration and validation tasks of future Chilean space missions.

  8. Radiometric dating

    International Nuclear Information System (INIS)

    Das, N.R.

    2017-01-01

    Since the discovery of natural radioactivity in uranium, in the last decade of the nineteenth century, the nuclear property of radioactive decay of radionuclides at immutable rates has been effectively utilized in dating of varieties of naturally occurring geological matrices and the organisms which constantly replenish their "1"4C supply through respiration when alive on earth. During the period, applications of radiometric dating techniques have been extensively diversified and have enabled the geologists to indicate the absolute time scales of geological formations and the evolution of the solar system, the earth, meteorites, lunar rocks, etc. and the archaeologists to record the facts of history of several important events like dinosaur era, Iceman, the Shroud in Turin and many other ancient artefacts. In the development of dating methods, varieties of naturally occurring radio-isotopic systems with favorable half-lives ranging from about 10 years to over 100 billion years have been used as radiometric clocks. (author)

  9. Rapid flow imaging method

    International Nuclear Information System (INIS)

    Pelc, N.J.; Spritzer, C.E.; Lee, J.N.

    1988-01-01

    A rapid, phase-contrast, MR imaging method of imaging flow has been implemented. The method, called VIGRE (velocity imaging with gradient recalled echoes), consists of two interleaved, narrow flip angle, gradient-recalled acquisitions. One is flow compensated while the second has a specified flow encoding (both peak velocity and direction) that causes signals to contain additional phase in proportion to velocity in the specified direction. Complex image data from the first acquisition are used as a phase reference for the second, yielding immunity from phase accumulation due to causes other than motion. Images with pixel values equal to MΔΘ where M is the magnitude of the flow compensated image and ΔΘ is the phase difference at the pixel, are produced. The magnitude weighting provides additional vessel contrast, suppresses background noise, maintains the flow direction information, and still allows quantitative data to be retrieved. The method has been validated with phantoms and is undergoing initial clinical evaluation. Early results are extremely encouraging

  10. A study on the radiometric method for evaluating element migration from plastic packagings to its contents

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez

    2008-01-01

    Over the past few years, problems related to food contamination by substances or elements that can be a risk to human health have became a concern, not only to government authorities, but to the general population as well. Within this context, plastic packaging can constitute a source of food contamination since plastic manufacturing processes involve the use of catalysts and different types of additives that may contain toxic elements. When food comes into contact with this packaging, components of the package may migrate to the food. In order to control the material used as food packaging, the National Health Surveillance Agency (ANVISA) in Brazil, has established boundary values of migrant substances and procedures to determine migration from plastic packagings to food. In this study the radiometric method was evaluated for element migration determination from plastic packaging to food simulating or to the food itself. This radiometric method consisted in irradiating plastic packaging samples with a thermal neutron flux from the IEA-R1 nuclear research reactor in order to produce radionuclides of elements present in the packagings. The irradiated plastic was then exposed to food simulant or food for element migration. Gamma ray spectrometry was used to measure radioactivity in the simulant or food in order to quantify the migration. The food simulating types and experimental conditions were established according to the ANVISA regulations. Element migration was studied for plastic packaging used for soft drinks, drinking water, milk, dairy products, juices and fatty foods. In the instrumental neutron activation analysis of these packagings the presence of As, Cd, Cr, Co and Sb II was verified. Results obtained from the migration experiments by the radiometric method indicated that Cd, Co, Cr and Sb present in these plastics migrated to the simulant or to the food. In some packagings, the migration of only some of these elements was observed. In these cases the

  11. Development of in-vitro radiometric assay for the rapid assessment of chloroquine resistant plasmodium vivax

    International Nuclear Information System (INIS)

    Myint Oo; Myo Khin; Nwe Nwe Oo

    1997-01-01

    Previously, resistance of malaria parasite to chloroquine has been restricted only to Plasmodium falciparum. Recently, there have been many reports of chloroquine-resistant Plasmodium vivax. One of the mechanisms of chloroquine resistance is the decreased uptake of chloroquine or rapid efflux of the drug from the food vacuole of the parasite. In this study, we have measured the rapid efflux of IH-chloroquine in fifty blood samples from patients with P Vivax infection. All 50 patients were hospitalised for 28 days for the standard treatment with chloroquine. It was found that seven patients who did not respond to the standard regimen of chloroquine have parasites with rapid effluxes of IH-chloroquine. Since rapid effluxes of IH-chloroquine in the resistant parasites showed strong correlation with in vivo 28 days clinical trial, this assay could be used as rapid assessment of chloroquine resistance in patients with P vivax infection

  12. Development of in-vitro radiometric assay for the rapid assessment of chloroquine resistant plasmodium vivax

    Energy Technology Data Exchange (ETDEWEB)

    Oo, Myint; Khin, Myo; Oo, Nwe Nwe [Department of Medical Research, Yangon (Myanmar)

    1997-12-01

    Previously, resistance of malaria parasite to chloroquine has been restricted only to Plasmodium falciparum. Recently, there have been many reports of chloroquine-resistant Plasmodium vivax. One of the mechanisms of chloroquine resistance is the decreased uptake of chloroquine or rapid efflux of the drug from the food vacuole of the parasite. In this study, we have measured the rapid efflux of IH-chloroquine in fifty blood samples from patients with P Vivax infection. All 50 patients were hospitalised for 28 days for the standard treatment with chloroquine. It was found that seven patients who did not respond to the standard regimen of chloroquine have parasites with rapid effluxes of IH-chloroquine. Since rapid effluxes of IH-chloroquine in the resistant parasites showed strong correlation with in vivo 28 days clinical trial, this assay could be used as rapid assessment of chloroquine resistance in patients with P vivax infection.

  13. State of the art and trends of radiometric methods for measuring the mass per unit area

    International Nuclear Information System (INIS)

    Bernhardt, R.

    1984-01-01

    The determination of the mass per unit area by means of transmission or backscattering methods is one of the traditional radioisotope applications. Microelectronics have essentially contributed to the noticeable progress achieved in the development of radiometric instruments for mass per unit area measurements. The use of microcomputers led to both a reliable solution of the main problem of processing the measured data - the correlation of the mass per unit area value with the detector signal under nonlinear calibration conditions - and a considerable increase in the efficiency of the measuring equipment

  14. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    International Nuclear Information System (INIS)

    Hovi, T.; Roivainen, M.

    1989-01-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with 51 Cr, [ 3 H]leucine, or, preferentially, with [ 3 H]uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30 degree C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well

  15. METHOD OF RADIOMETRIC DISTORTION CORRECTION OF MULTISPECTRAL DATA FOR THE EARTH REMOTE SENSING

    Directory of Open Access Journals (Sweden)

    A. N. Grigoriev

    2015-07-01

    Full Text Available The paper deals with technologies of ground secondary processing of heterogeneous multispectral data. The factors of heterogeneous data include uneven illumination of objects on the Earth surface caused by different properties of the relief. A procedure for the image restoration of spectral channels by means of terrain distortion compensation is developed. The object matter of this paper is to improve the quality of the results during image restoration of areas with large and medium landforms. Methods. Researches are based on the elements of the digital image processing theory, statistical processing of the observation results and the theory of multi-dimensional arrays. Main Results. The author has introduced operations on multidimensional arrays: concatenation and elementwise division. Extended model description for input data about the area is given. The model contains all necessary data for image restoration. Correction method for multispectral data radiometric distortions of the Earth remote sensing has been developed. The method consists of two phases: construction of empirical dependences for spectral reflectance on the relief properties and restoration of spectral images according to semiempirical data. Practical Relevance. Research novelty lies in developme nt of the application theory of multidimensional arrays with respect to the processing of multispectral data, together with data on the topography and terrain objects. The results are usable for development of radiometric data correction tools. Processing is performed on the basis of a digital terrain model without carrying out ground works connected with research of the objects reflective properties.

  16. An in vitro study of dental enamel wear by restorative materials using radiometric method

    International Nuclear Information System (INIS)

    Adachi, Lena Katekawa

    2000-01-01

    There is an increasing demand and interest to study the dental materials wear as well as about the abrasion effect on antagonistic teeth. Due to the fact that the existent restorative materials have no specifications about their abrasiveness, it is necessary the establishment of degrees of comparison among them to support clinical application. In this work, the radiometric method was applied to study the enamel wear caused by another enamel and by restorative materials (Ceramco II, Noritake and Finesse porcelains, Artglass and Targis). The dental enamel made radioactive by irradiation at the IEA-R1m nuclear research reactor under a thermal neutron flux was submitted to wear in a machine which allows sliding motion of an antagonistic surface in contact with this radioactive enamel. The enamel wear was evaluated by measuring beta activity of 32 P transferred to water from this irradiated tooth. Results obtained indicated that dental porcelains cause pronounced enamel wear when compared with that provoked by another enamel or by resin materials. Resin materials caused less enamel wear than another enamel. Vickers microhardness data obtained for antagonistic materials showed a correlation with the wear caused to the enamel. This study allowed to conclude that the radiometric method proposed can be used satisfactorily in the evaluation of enamel wear by restorative materials. This method presents advantages due to quick responses and ease of analyses There is (author)

  17. Radiometric method for the characterization of particulate processes in colloidal suspensions. II. Experimental verification of the method

    Energy Technology Data Exchange (ETDEWEB)

    Subotic, B. [Institut Rudjer Boskovic, Zagreb (Yugoslavia)

    1979-09-15

    A radiometric method for the characterization of particulate processes is verified using stable hydrosols of silver iodide. Silver iodide hydrosols satisfy the conditions required for the applications of the proposed method. Comparison shows that the values for the change of particle size measured in silver iodide hydrosols by the proposed method are in excellent agreement with the values obtained by other methods on the same systems (electron microscopy, sedimentation analysis, light scattering). This shows that the proposed method is suitable for the characterization of particulate processes in colloidal suspensions. (Auth.).

  18. A radiometric method for the determination of NADH in subpicomole amounts

    International Nuclear Information System (INIS)

    Weber, G.; Rosenthal, W.; Oberdisse, E.

    1988-01-01

    A radiometric method has been devised for the determination of small quantities of NADH formed in preceding dehydrogenase reactions. In a coupled enzymatic reaction, phosphoglycerate kinase (PGK) catalyzes the transfer of [/sup 32/P]orthophosphate from [gamma-/sup 32/P]ATP to 3-phosphoglycerate; the intermediate, 1,3-[1-/sup 32/P]diphosphoglycerate, is dephosphorylated by glyceraldehyde-3-phosphate dehydrogenase (GAP-DH). [/sup 32/P]Orthophosphate is released proportionally to NADH and can be measured after adsorption of [gamma-/sup 32/P]ATP to activated charcoal. With this method, 0.2 pmol of NADH are detectable in the presence of a 10/sup 4/-fold excess of NAD over NADH

  19. Characterisation of radioactive contaminated materials by combined radiometric and spectrometric methods

    International Nuclear Information System (INIS)

    Dulama, C.; Toma, A.; Dobrin, R.; Ciocîrlan, C.; Stoica, S.; Valeca, M.; Popescu, I. I.

    2013-01-01

    In the present paper, a combined analytical methodology is described, for characterization of radioactive contaminated materials. The subject of testing activities was a set of solutions provided by the Cernavoda NPP, which are originating from processes of radiological survey of workplaces in the plant. In the introduction section, a theoretical approach was given to the origin and nature of main radionuclides occurring in the primary cooling system of the nuclear power plant, with the aim to establish selection criteria and performance requirements for the analytical methods to be used in the development of the characterization methodology. A combination of radiometric and spectrometric methods was selected, based on gross beta counting, high resolution gamma-ray spectrometry and liquid scintillation counting. (authors)

  20. Radiometric macrophage culture assay for rapid evaluation of antileprosy activity of rifampin

    Energy Technology Data Exchange (ETDEWEB)

    Mittal, A.; Seshadri, P.S.; Prasad, H.K.; Sathish, M.; Nath, I.

    1983-10-01

    The antileprosy effect of rifampin was evaluated by a newly developed rapid in vitro assay wherein 31 human-derived strains and 1 armadillo-derived strain of Mycobacterium leprae were maintained for 2 and 3 weeks, respectively, in murine and human macrophages in the presence of (3H)thymidine. Of these strains, 27 showed significant incorporation of the radiolabel in cultures of live bacilli as compared with control cultures of heat-killed bacilli of the same strain. Consistent and significant inhibition of (3H)thymidine uptake was observed in M. leprae resident cultures with 3 to 200 ng of rifampin per ml as compared with similar cultures without the drug. In general, an increase in percent inhibition was seen from 3 to 20 ng/ml, with marginal increases at 40, 50, and 100 ng/ml. M. leprae strains appear to be remarkably susceptible to this drug in the in vitro assay.

  1. Radiometric macrophage culture assay for rapid evaluation of antileprosy activity of rifampin

    International Nuclear Information System (INIS)

    Mittal, A.; Seshadri, P.S.; Prasad, H.K.; Sathish, M.; Nath, I.

    1983-01-01

    The antileprosy effect of rifampin was evaluated by a newly developed rapid in vitro assay wherein 31 human-derived strains and 1 armadillo-derived strain of Mycobacterium leprae were maintained for 2 and 3 weeks, respectively, in murine and human macrophages in the presence of [3H]thymidine. Of these strains, 27 showed significant incorporation of the radiolabel in cultures of live bacilli as compared with control cultures of heat-killed bacilli of the same strain. Consistent and significant inhibition of [3H]thymidine uptake was observed in M. leprae resident cultures with 3 to 200 ng of rifampin per ml as compared with similar cultures without the drug. In general, an increase in percent inhibition was seen from 3 to 20 ng/ml, with marginal increases at 40, 50, and 100 ng/ml. M. leprae strains appear to be remarkably susceptible to this drug in the in vitro assay

  2. Rapid prototyping: een veelbelovende methode

    NARCIS (Netherlands)

    Haverman, T.M.; Karagozoglu, K.H.; Prins, H.; Schulten, E.A.J.M.; Forouzanfar, T.

    2013-01-01

    Rapid prototyping is a method which makes it possible to produce a three-dimensional model based on two-dimensional imaging. Various rapid prototyping methods are available for modelling, such as stereolithography, selective laser sintering, direct laser metal sintering, two-photon polymerization,

  3. Ground Radiometric Method as a Tool for Determining the Surface Boundary of a Buried Bauxitic Karst

    Directory of Open Access Journals (Sweden)

    Kamal Kareem Ali

    2011-12-01

    Full Text Available Forty two ground radiometric measurements along nine traverses within a rectangular network area were taken across a bauxitic karst within the Ubaid Formation (Lower Jurassic in the Western Desert of Iraq. A 4-Channel Gamma Ray Spectrometer (GAD-6 with sodium iodide NaI (Tl crystal (GSP-4S was used in the field to measure the total radioactivity of the surface soil. Soil samples collected from the surface at each measurement point and core samples collected from a test well penetrating the karst were analyzed by Gamma ray spectrometer. The main objective of this study was to detect the hidden bauxitic karst and determine its surface boundary. The radioactivity on the surface of the karst was ranging between 60 and 80 count per second (c/s, while the background radioactivity of the Ubaid Formation, which hosts the karst, was ranging between 100 and150 c/s. Chemical weathering, especially dissolution and leaching moved uranium (238U and thorium(232Th from the overburden downward. Accordingly, these elements have been adsorbed on the surface of clay minerals and bauxite buried at a depth of about 5m causing enrichment with radioactivity. The leached overburden lack radioelements, so its radioactivity was less than background radioactivity level. The gamma ray spectroanalysis showed that the radioactivity of 238U and 232Th in the overburden was 0.5 and 3 Bq/Kg, whereas, in the bauxite and flint clay bed, it was 240 and 160 Bq/Kg respectively. Based on the radioactivity anomaly contrast on the surface, an isorad map was plotted and the karst diameter which represents low anomaly was determined to be ranging from 150 to 200m. The current study demonstrates that the ground radiometric method is quite useful for detecting the bauxitic karst and inferring its surface boundaries.

  4. Radiometric diagnosis of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Laszlo, A.

    1986-01-01

    The results of this study confirm that rapid radiometric diagnostic tests such as the NAP selective inhibition test for the M. tuberculosis complex followed by the radiometric drug susceptibility tests are extremely reliable and compare favourably with conventional methodologies. This study also shows that referred cultures growing on solid medium can be processed by radiometric procedures without prior subculture. This circumstance by itself shortens the time needed for reporting. (Auth.)

  5. Development and application of a radiometric method of measurement (Heger probe) for characterizing clastic rock strata in exposures

    International Nuclear Information System (INIS)

    Koch, G.

    1984-01-01

    The radiometric image of a stratigraphic exposure profile was to be logged. The method of measurement was tested on clastic sediments of the Tertiary (Saudi Arabia) and Bunter (Northern Germany). The well-tried scintillometer technique was supplemented by modern technological means supplied by a prospecting company (Gewerkschaft Brunhilde). The probe applied was specifically developped for stratigraphic purposes. (orig./HP) [de

  6. Evaluation of a rapid radiometric differentiation test for the Mycobacterium tuberculosis complex by selective inhibition with p-nitro-alpha-acetylamino-beta-hydroxypropiophenone

    International Nuclear Information System (INIS)

    Laszlo, A.; Siddiqi, S.H.

    1984-01-01

    This study is an evaluation of a rapid technique for the differentiation of the Mycobacterium tuberculosis complex from other mycobacteria, using p-nitro-alpha-acetylamino-beta- hydroxypropiophenone (NAP) as a selective inhibitory agent. A total of 416 coded cultures, 234 cultures belonging to the M. tuberculosis complex and 182 cultures belonging to 35 other mycobacterial species, were tested in two laboratories for p-nitro-alpha-acetylamino-beta- hydroxypropiophenone inhibition to concentrations of 5 and 10 micrograms of NAP per ml in Middlebrook 7H12 liquid medium. Two testing modes were compared: the indirect, in which a large bacterial inoculum was used from an isolated culture on a solid medium, and the direct, which used a small inoculum from 7H12 medium. A decrease or no increase in daily 14 CO 2 output as measured by a BACTEC system was considered evidence of inhibition. The data presented show that a concentration of 5 micrograms of NAP per ml can effectively separate the M. tuberculosis complex from other mycobacterial species in 4 to 6 days. The direct test data show that, unlike other conventional biochemical tests, it does not require a heavy inoculum of mycobacteria and can therefore be performed soon after growth is detected by the radiometric method

  7. Method for radiometric calibration of an endoscope's camera and light source

    Science.gov (United States)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  8. Analysis of differential method for compensating fluctuations in product thickness when radiometric testing

    International Nuclear Information System (INIS)

    Pokrovskij, A.V.; Kvasnitsa, M.S.

    1979-01-01

    Given are the estimates of information capabilities of the differential method for measuring radiation flux in radiation defectoscopy as well as efficiency of application of automatic radiation facilities to control taking into account the statistical regularities of product thickness fluctuations. Dependences of signal to noise ratio on the regularities of product thickness fluctuations have been found and optimization, on this basis, of the design and parameters of processing instrumentation was carried out. It is shown, that with 60-80 mm interval of product thickness fluctuations correlation (welded joints) it is expedient to use two radiation beams with their crossing on a mean product plane. When the interval of correlation of thickness fluctuations is great it is effective to use the geometry of radioscopy with parallel radiation beams. This permits to use only one radiation source without significant reducing the compensation efficiency, that in most cases simplifies the development and application of radiometric systems. Thus the efficiency of applying the differential method for radiation beam detection to compensate product thickness fluctuations is primarily determined by statistical regularities of the given fluctuations. The account of the regularities in the development of the processing instrumentation results in the most complete extraction of useful information, containing in the radiation beams being detected

  9. Evaluation of a radiometric method for pyrazinamide susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Tarrand, J.J.; Spicer, A.D.; Groeschel, D.H.

    1986-01-01

    Pyrazinamide susceptibility testing of Mycobacterium tuberculosis requires an acid environment. By controlling the method of acidification and the quality and quantity of the inoculum, the test can be performed with the BACTEC radiometric system (Johnston Laboratories, Towson, Md.). We acidified BACTEC 7H12 medium with buffered phosphoric acid and adjusted the test inoculum to 1/10 of that usually employed in BACTEC protocols; after 5 days of growth we correctly identified 36 of 36 strains susceptible to 50 micrograms of pyrazinamide per ml. All 18 resistant strains were classified as pyrazinamide resistant. (Susceptibility or resistance had been determined by standard plate assays.) The test was able to detect small resistant populations in artificial mixtures of 1 or 2% resistant bacteria with a susceptible strain (10 mixtures each). We tested 70 M. tuberculosis strains in acidified BACTEC 7H12 medium and by the plate dilution test at pH 5.5. All strains grew in the BACTEC medium, but three strains failed to grow on plates and were not tested further; the results of both methods agreed for the remaining strains

  10. Radiometric determination of monoethanolamine with 65ZnSo4

    International Nuclear Information System (INIS)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S.

    1984-01-01

    Determination of milligram amounts of monoethanolamine (MEA) with zinc(II) by radiometric titration is described. When MEA is added to a zinc(II) solution containing sulphate ions at 25 degC, a white solid complex is formed. The formation of this complex is employed for the radiometric determination of MEA with 65 Zn. The amount of MEA is directly proportional to the activity of the complex formed. The method is simple, rapid and accurate. (author)

  11. Investigations with a simplified method for radiometric determination of vitamin B12 in body fluids and feeding stuffs

    International Nuclear Information System (INIS)

    Menke, K.H.; Kohlberger, G.; Koenemund, A.

    1979-01-01

    A modified method for radiometrical determination of vitamin B 12 is described, which in difference to the known methods is based on measurement of free B 12 after absorption to albumin-coated charcoal instead of measurement of intrinsic factor B 12 -complex. The conditions for extraction from serum, milk, rumen-liquor and urine have been investigated and the effect of pH on IF-B 12 -binding in presence of these body fluids examined. Parallel microbiological determinations (O.m.- and L.1.-test) were in good correlation (r = 0,93-0,97) to radiometrically determined B 12 -contents in milk and rumen-liquor, but not to that in serum of dairy cows (r = 0,54-0,82). The analytical procedures are given in detail. (orig.) [de

  12. Uncertainty Evaluations of the CRCS In-orbit Field Radiometric Calibration Methods for Thermal Infrared Channels of FENGYUN Meteorological Satellites

    Science.gov (United States)

    Zhang, Y.; Rong, Z.; Min, M.; Hao, X.; Yang, H.

    2017-12-01

    Meteorological satellites have become an irreplaceable weather and ocean-observing tool in China. These satellites are used to monitor natural disasters and improve the efficiency of many sectors of Chinese national economy. It is impossible to ignore the space-derived data in the fields of meteorology, hydrology, and agriculture, as well as disaster monitoring in China, a large agricultural country. For this reason, China is making a sustained effort to build and enhance its meteorological observing system and application system. The first Chinese polar-orbiting weather satellite was launched in 1988. Since then China has launched 14 meteorological satellites, 7 of which are sun synchronous and 7 of which are geostationary satellites; China will continue its two types of meteorological satellite programs. In order to achieve the in-orbit absolute radiometric calibration of the operational meteorological satellites' thermal infrared channels, China radiometric calibration sites (CRCS) established a set of in-orbit field absolute radiometric calibration methods (FCM) for thermal infrared channels (TIR) and the uncertainty of this method was evaluated and analyzed based on TERRA/AQUA MODIS observations. Comparisons between the MODIS at pupil brightness temperatures (BTs) and the simulated BTs at the top of atmosphere using radiative transfer model (RTM) based on field measurements showed that the accuracy of the current in-orbit field absolute radiometric calibration methods was better than 1.00K (@300K, K=1) in thermal infrared channels. Therefore, the current CRCS field calibration method for TIR channels applied to Chinese metrological satellites was with favorable calibration accuracy: for 10.5-11.5µm channel was better than 0.75K (@300K, K=1) and for 11.5-12.5µm channel was better than 0.85K (@300K, K=1).

  13. A study of elemental migration from poly(ethylene terephthalate) of food packagings to simulated solutions by radiometric method

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez; Saki, Mitiko; Silva, Leonardo G.A.

    2007-01-01

    Brazilian plastic production for food packagings, in recent years, has grown in the same proportion as food consumption. Considering that the plastic manufacturing involves catalytic processes and the use of additives, when the foods are in direct contact with these materials, the components present in plastics may migrate to the food. The Brazilian Health Surveillance Agency (ANVISA) has established boundary-values of migrants as well as procedures to evaluate migration of elements and substances from plastic packaging to food. In this study elemental composition of poly (ethylene terephthalate) - PET - packaging and results of elemental migration were obtained. Instrumental Neutron Activation Analysis (INAA) was used to determine elemental concentrations in PET packagings and the radiometric method was applied for elemental migration determination. This radiometric method consisted of irradiating the PET samples with neutrons, followed by migration exposition and radioactivity measurement in food-simulated solution. Experimental conditions used for migration were 10 days exposure period at 40 deg C. Migration was evaluated for soft drink, juice and water PET packaging. The analytical results indicated that PET packagings contain Co and Sb and those elements are transferred to the simulated solutions. However, these migration results were lower than the maximum tolerance values established by ANVISA. The migration detection limits also indicated high sensitivity of the radiometric method. (author)

  14. A simple and effective radiometric correction method to improve landscape change detection across sensors and across time

    Science.gov (United States)

    Chen, X.; Vierling, Lee; Deering, D.

    2005-01-01

    Satellite data offer unrivaled utility in monitoring and quantifying large scale land cover change over time. Radiometric consistency among collocated multi-temporal imagery is difficult to maintain, however, due to variations in sensor characteristics, atmospheric conditions, solar angle, and sensor view angle that can obscure surface change detection. To detect accurate landscape change using multi-temporal images, we developed a variation of the pseudoinvariant feature (PIF) normalization scheme: the temporally invariant cluster (TIC) method. Image data were acquired on June 9, 1990 (Landsat 4), June 20, 2000 (Landsat 7), and August 26, 2001 (Landsat 7) to analyze boreal forests near the Siberian city of Krasnoyarsk using the normalized difference vegetation index (NDVI), enhanced vegetation index (EVI), and reduced simple ratio (RSR). The temporally invariant cluster (TIC) centers were identified via a point density map of collocated pixel VIs from the base image and the target image, and a normalization regression line was created to intersect all TIC centers. Target image VI values were then recalculated using the regression function so that these two images could be compared using the resulting common radiometric scale. We found that EVI was very indicative of vegetation structure because of its sensitivity to shadowing effects and could thus be used to separate conifer forests from deciduous forests and grass/crop lands. Conversely, because NDVI reduced the radiometric influence of shadow, it did not allow for distinctions among these vegetation types. After normalization, correlations of NDVI and EVI with forest leaf area index (LAI) field measurements combined for 2000 and 2001 were significantly improved; the r 2 values in these regressions rose from 0.49 to 0.69 and from 0.46 to 0.61, respectively. An EVI "cancellation effect" where EVI was positively related to understory greenness but negatively related to forest canopy coverage was evident across a

  15. RADIOMETRIC BLOCK ADJUSMENT AND DIGITAL RADIOMETRIC MODEL GENERATION

    Directory of Open Access Journals (Sweden)

    A. Pros

    2013-05-01

    Full Text Available In this paper we present a radiometric block adjustment method that is related to geometric block adjustment and to the concept of a terrain Digital Radiometric Model (DRM as a complement to the terrain digital elevation and surface models. A DRM, in our concept, is a function that for each ground point returns a reflectance value and a Bidirectional Reflectance Distribution Function (BRDF. In a similar way to the terrain geometric reconstruction procedure, given an image block of some terrain area, we split the DRM generation in two phases: radiometric block adjustment and DRM generation. In the paper we concentrate on the radiometric block adjustment step, but we also describe a preliminary DRM generator. In the block adjustment step, after a radiometric pre-calibraton step, local atmosphere radiative transfer parameters, and ground reflectances and BRDFs at the radiometric tie points are estimated. This radiometric block adjustment is based on atmospheric radiative transfer (ART models, pre-selected BRDF models and radiometric ground control points. The proposed concept is implemented and applied in an experimental campaign, and the obtained results are presented. The DRM and orthophoto mosaics are generated showing no radiometric differences at the seam lines.

  16. A radiometric method for the determination of cationic detergents with the aid of Rose Bengal labelled with 131I

    International Nuclear Information System (INIS)

    Lengyel, J.; Krtil, J.; Vecernik, J.

    1983-01-01

    A novel radiometric method for the determination of cationic detergents represented by carbetoxypentadecyltrimethylammonium bromide (Septonex) is described. The method is based on the extraction of an ion associate Septonex-Rose Bengal from an alkaline medium into chloroform. Rose Bengal labelled with 131 I ( 131 I-RB) was used as a radioreagent. The 131 I activity in the extract is proportional to the cationic detergent concentration in the solution to be analyzed. The optimum conditions for the determination of Septonex were found and the composition of the extractable complexes Rose Bengal-Septonex was determined. (author)

  17. Radiometric analyzer

    International Nuclear Information System (INIS)

    Arima, S.; Oda, M.; Miyashita, K.; Takada, M.

    1977-01-01

    A radiometric analyzer for measuring the characteristic values of a sample by radiation includes a humer of radiation measuring subsystems having different ratios of sensitivities to the elements of the sample and linearizing circuits having inverse function characteristics of calibration functions which correspond to the radiation measuring subsystems. A weighing adder operates a desirable linear combination of the outputs of the linearizing circuits. Operators for operating between two or more different linear combinations are included

  18. Rapid radiometric detection of microbial contamination using 14C-glucose and standard liquid scintillation counting system

    International Nuclear Information System (INIS)

    Joshi, S.H.; Kamble, S.B.; Pilkhwal, N.S.; Ramamoorthy, N.

    1998-01-01

    A simple and rapid method for detection of microbial contamination based on quantitation of 14 CO 2 released during metabolism of 14 C-Glucose by microorganisms is reported. Liquid scintillation counting system (LSCS) with a modified sample preparation method was utilised. The scintillator was impregnated on Whatman-1 paper on which 14 CO 2 evolved during metabolism could be absorbed. The important parameters of counting such as efficiency, position sensitivity and geometry as well as effect of NaOH quantity and of microbial load on detection period were studied. The efficiency of radioactivity assay was 18±2.8 %. Contamination of the order of 5-10 organism/ml of product could be detected in about 24 hours. (author)

  19. Determination of uranium and thorium contents using a 14 MeV neutron generator and a radiometric method

    International Nuclear Information System (INIS)

    Casagrande, J.A.

    1981-04-01

    A simple method was developed which can determine uranium and thorium in uranium ores, by 14MeV neutron activation and delayed neutron counting. The process can be used in field laboratories to select samples for processing. The method does not require a previous treatment of the samples and the analysis time is below 5 minutes. The detection limit of the method is about 2 ppm, when the yield of the 14MeV source has a value of 2 X 10 11 neutrons/second, and an optimized delayed neutron counter is used. A radiometric method is used determine separately the thorium content of the sample, and this result is combined with the activation one in order to obtain uranium content. The radiometric method in the counting of the 2,6 MeV gamma rays from 208 Tl using a NaI(Tl) detector. Delayed neutron counting is performed with BF 3 detectors inside a paraffin box. The problem of radioactive equilibrium does not affect thorium determination since the biggest activities of thorium daughters are much smaller than the times involved in the displacements of mineral which can give origin to the radioactive desequilibrium. (Author) [pt

  20. Study of extraction chromatography methods of separation of neptunium and its radiometric determination

    International Nuclear Information System (INIS)

    Reich, M.

    2009-04-01

    In presented dissertation thesis the separation procedure for determination of neptunium in model solutions and also in soil samples was designed. 1. The sorbent was prepared on basis of hydrophobised silica gel with silica oil for hydrophobisation - Lukooil H. Extraction agent was anchored on this modified surface -quarternary ammonium salt Aliquat 336. In experiments was proved, that sorbent prepared like this is resist enough to the elution solutions using in separation procedures. It was found out that maximal concentration of deposited Aliquat 336 in benzene on hydrophobised silica gel selected granulate size is 40%. Sorbent prepared with silica gel lower granulate size and also with higher concentration of Aliquat 336 in benzene became sticky and unsuitable for using in separation columns. 2. The prepared sorbent is similar to commercial produced TEVA resin made by company Eichrom and for purpose of this project it was cheaper but the same effective alternative in comparing to mentioned commercial resin. 3. The separation procedure for isolation of 237 Np from radionuclides interfering during its radiometric determination with alpha spectrometry was designed -in scientific publications hasn't been described yet. The procedure consists of using formic acid for reduction of radionuclides interfering by alpha spectrometric determination of 237 Np and subsequent purification of neptunium on the next column by using ferrous sulphamate as reduction agent. This procedure was applied to the model solutions and also to the soil samples. The model solutions and soil samples for these experiments were contaminated with known amounts of 237 Np, 238 pU, 232 Th and mixture of 234 U/ 238 U. The effective separation of neptunium from described radionuclides was achieved with application of the described separation procedure. 4. The separation procedure for separation of 239 Np from its mother radionuclide 241 Am was designed with prepared sorbent. Different washing and

  1. Detection of group D and viridans streptococci in blood by radiometric methods

    International Nuclear Information System (INIS)

    Beckwith, D.G.

    1979-01-01

    A prospective study was conducted to evaluate the radiometric detection of group D and viridans streptococci in blood, using three media preparations, Bactec 6A and 6B isotonic media and 8B hypertonic medium. All enterococci tested were detected by the 6A and 6B media. However, the 6A medium failed to detect 76% of the Streptococcus bovis isolates and 57% of the viridans streptococci, whereas all S. bovis isolates and 95% of the viridans streptococci were detected with the 6B formulation. No improvement in detection was noted in comparing the 6B and the 8B hypertonic media. The importance of adequate detection of this group of organisms, especially in patients with endocarditis, is discussed

  2. Radiometric geological exploration method used in the central part of the State of Sonora

    International Nuclear Information System (INIS)

    Pacheco R, R.

    1978-01-01

    The purpose of this study is to make known the importance of the radiometric data, the physical principles on which they are based and the geological interpretation which will permit in an indirect way to select important radioactive areas in order to carry out verification studies on the ground to see if there are sufficient reasons to show any interest in these areas. Till now this work has been realized in the State of Sonora (Mexico) in an area of 51,000 Km 2 subdivided in 14 zones, numbered from 201 to 214, and for the present work the zone 208 has been selected. This Zone is located at the north-west of the City of Hermosillo, and has a total area of 3400 Km 2 which has been the object of the study by plane through systematic flights in an east-west direction, in order to obtain the configuration and interpret it from a radiometrical point of view. The obtained isorads configuration plans of 4 channels of detection are the following: total counting, potassium, bismuth and thallium as well as their relations. From the 14 verified anomalies the anomaly Noche Buena was selected in order to carry out reconnaissance surveys and preliminary and detailed geological studies. The geology of the area is represented by extrusive and intrusive igneous rocks as well as sedimentary. The uraniferous mineralization is secondary and is represented by autunite, meta-autunite and torbenite which represent an average of 200 g to 3.08 Kg. of U 3 O 8 per ton. (author)

  3. Radiometric emanation method for the assessment of the durability of building materials towards aggressive media

    International Nuclear Information System (INIS)

    Balek, V.; Beckman, I.N.

    1991-01-01

    A new express method has been suggested for testing durability of building materials in contact with aggressive liquids and gases. The method is based on the measurement of radon released from samples studied, continuously during the interaction of the sample with the aggressive medium. The samples are previously labeled by the source of radon atoms, i.e. thorium Th-228 and radium Ra-224 are incorporated in the samples to be tested. Due to high sensitivity of the method the first stages of the interaction between the cement stone (concrete) sample and aggressive liquid or gas can be followed. The express information about the relative durability of the building materials was obtained. This method was also advantageously used for the investigation of corrosion early stage of marble (calcium carbonate) by sulphur dioxide (in the concentrations of 500-3,000 ppm). The most advantageous application of the method is for rapid assessment of the relative durability of building materials, e.g. the information about the relative durability of the samples studied was obtained within several minutes, resp. hours, whereas by means of traditional chemical methods it needs several weeks or months

  4. Radiometric enrichment of nonradioactive ores

    International Nuclear Information System (INIS)

    Mokrousov, V.A.; Lileev, V.A.

    1979-01-01

    Considered are the methods of mineral enrichment based on the use of the radioation of various types. The physical essence of enrichment processes is presented, their classification is given. Described are the ore properties influencing the efficiency of radiometric enrichment, methods of the properties study and estimation of ore enrichment. New possibilities opened by radiometric enrichment in the technology of primary processing of mineral raw materials are elucidated. A considerable attention is paid to the main and auxiliary equipment for radiometric enrichment. The foundations of the safety engineering are presented in a brief form. Presented are also results of investigations and practical works in the field of enrichment of ores of non-ferrous, ferrous and non-metallic minerals with the help of radiometric methods

  5. A novel method for destriping of OCM-2 data and radiometric performance analysis for improved ocean color data products

    Science.gov (United States)

    Singh, Rakesh Kumar; Shanmugam, Palanisamy

    2018-06-01

    Despite the capability of Ocean Color Monitor aboard Oceansat-2 satellite to provide frequent, high-spatial resolution, visible and near-infrared images for scientific research on coastal zones and climate data records over the global ocean, the generation of science quality ocean color products from OCM-2 data has been hampered by serious vertical striping artifacts and poor calibration of detectors. These along-track stripes are the results of variations in the relative response of the individual detectors of the OCM-2 CCD array. The random unsystematic stripes and bandings on the scene edges affect both visual interpretation and radiometric integrity of remotely sensed data, contribute to confusion in the aerosol correction process, and multiply and propagate into higher level ocean color products generated by atmospheric correction and bio-optical algorithms. Despite a number of destriping algorithms reported in the literature, complete removal of stripes without residual effects and signal distortion in both low- and high-level products is still challenging. Here, a new operational algorithm has been developed that employs an inverted gaussian function to estimate error fraction parameters, which are uncorrelated and vary in spatial, spectral and temporal domains. The algorithm is tested on a large number of OCM-2 scenes from Arabian Sea and Bay of Bengal waters contaminated with severe stripes. The destriping effectiveness of this approach is then evaluated by means of various qualitative and quantitative analyses, and by comparison with the results of the previously reported method. Clearly, the present method is more effective in terms of removing the stripe noise while preserving the radiometric integrity of the destriped OCM-2 data. Furthermore, a preliminary time-dependent calibration of the OCM-2 sensor is performed with several match-up in-situ data to evaluate its radiometric performance for ocean color applications. OCM-2 derived water

  6. Rapid method to determine actinides and 89/90Sr in limestone and marble samples

    International Nuclear Information System (INIS)

    Maxwell, S.L.; Culligan, Brian; Hutchison, J.B.; Utsey, R.C.; Sudowe, Ralf; McAlister, D.R.

    2016-01-01

    A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89 / 90 Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. This approach has a sample preparation time for limestone and marble samples of <4 h. (author)

  7. Use of the radiometric method at creation cell test-systems for pre-screening of anticancer preparations

    International Nuclear Information System (INIS)

    Kuznetsova, N.N.; Khashimova, Z.S.; Sadikov, A.A.

    2004-01-01

    Full text: Development of cancer chemotherapy is tightly bound with investigation of biological activity of different compounds on in vitro test systems. Our research has been directed on definition of sensitivity of the cell line KML removed by us from passed of mice melanoma B-16. We had been investigated action of 18 clinical antineoplastic preparations of different classes: alkylating - sarcolysinum, thiophosphamide, dopan, fhthordopan; antimetabolites - cytararibinum, methotrexatum, 6-mercaptopurinum, 5-fhthorouracilum, fhthorafur; antineoplastic antibiotics- adriamycinum, neomycinum, rubomycinum, bruneomycinum, carminomycinum, olivomycinum; plant substances - vinblastinum, colchaminum (component of ointment which used at treatment of skin cancer) and other - carboplatin. Cytotoxic effect of preparations estimated two methods - radiometric on inclusion of 3H - timidine in cells and spectrophotometric by definition of total amount nucleic acids and protein. For this purpose KML cells passed in quantity of 120 thousand in 3 ml of nutrient medium RPMI 1640, 10 % calf embryo serum in bottles and after 24 hours entered substances in dozes from 0,01 up to 100 μg/ml. Contact of substances to cells was 24 hours, then 10 μ Ci 3 H - timidine was injected on bottles at 1 hour. Cells transferred on GFC-filters, washed from not connected label. Filters transferred in scintillation liquid and a level of a radio-activity determined on β-counter. All tested clinical preparations appeared active within the criteria of activity, thus the radiometric method was more sensitive, than spectrophotometric. Thus, testing results of model have shown that stable cell line KML was sensitive to action of 18 clinical preparations with various mechanisms of action by different estimations of damaging action. This model can be used for biological activity of new potential cancerolytics pre-screening. This work was supported by the Center of Science and Technology of the Republic of

  8. Radiometric determination of monoethanolamine with /sup 65/ZnSo/sub 4/

    Energy Technology Data Exchange (ETDEWEB)

    Varadan, R; Sriman Narayanan, S; Rao, V R.S. [Indian Inst. of Tech., Bombay. Dept. of Chemistry

    1984-05-07

    Determination of milligram amounts of monoethanolamine (MEA) with zinc(II) by radiometric titration is described. When MEA is added to a zinc(II) solution containing sulphate ions at 25 degC, a white solid complex is formed. The formation of this complex is employed for the radiometric determination of MEA with /sup 65/Zn. The amount of MEA is directly proportional to the activity of the complex formed. The method is simple, rapid and accurate. 8 refs.

  9. The development and application of quantitative methods for the determination of in-situ radiometric uranium grade on the Witwatersrand gold and uranium mines

    International Nuclear Information System (INIS)

    Symons, G.

    1985-12-01

    A detailed investigation of background radiation levels near the reef zone in the uranium section of the Western Areas Mine was conducted using a collimated radiometric face scanner. This study demonstrated that these radiation levels can be high; 25% or more of the counts measured when sampling a reef face may originate from a background source, especially from uranium ore rubble on the footwall close to the reef face. A method using a 20mm frontal shield was devised to obtain an accurate background correction. Three calibration schemes, the Area method, the Gamlog method, and the Deconvolution method were implemented for the production of accurate in-situ radiometric uranium grades. This involved the construction of a step-response calibration pad at Pelindaba together with the establisment of appropriate software and underground radiometric sampling procedures. Radiometric grades generated by these calibration procedures from 60 channel sections were on average 10% below those procured from conventional chip sampling. A correlation between gold and uranium grades was also evident. Crushed rock samples were collected to investigate the thorium problem and are still undergoing analysis at the time of writing. Refinements in the design of the collimated face scanner are also described

  10. Rapid methods for detection of bacteria

    DEFF Research Database (Denmark)

    Corfitzen, Charlotte B.; Andersen, B.Ø.; Miller, M.

    2006-01-01

    Traditional methods for detection of bacteria in drinking water e.g. Heterotrophic Plate Counts (HPC) or Most Probable Number (MNP) take 48-72 hours to give the result. New rapid methods for detection of bacteria are needed to protect the consumers against contaminations. Two rapid methods...

  11. Urease testing of mycobacteria with BACTEC radiometric instrumentation

    International Nuclear Information System (INIS)

    Damato, J.J.; Collins, M.T.; McClatchy, J.K.

    1982-01-01

    A total of 140 mycobacterial isolates from patients treated at Fitzsimons Army Medical Center or the National Jewish Hospital and Research Center and from animal specimens submitted to the National Veterinary Services Laboratory were tested by using a urease procedure modified for use with a BACTEC model 301. Mycobacterial suspensions were prepared by using Middlebrook 7H10 Tween broth. Of the 98 mycobacteria isolates which were urease positive utilizing standard methodology, all were positive using the radiometric procedures. Similarly, all 42 urease-negative isolates were also negative employing the new methodology. Although maximum radiometric readings were observed at 48 h, all positive strains were readily identified 24 h after inoculation without sacrificing either test sensitivity or specificity. Thus, urease testing of mycobacteria, using the modified BACTEC radiometric methodology, was as sensitive, as specific, and more rapid than conventional methods

  12. Rapid presumptive identification of the Mycobacterium tuberculosis-bovis complex by radiometric determination of heat stable urease

    International Nuclear Information System (INIS)

    Gandy, J.H.; Pruden, E.L.; Cox, F.R.

    1983-01-01

    Simple and rapid Bactec methodologies for the determination of neat (unaltered) and heat stable urease activity of mycobacteria are presented. Clinical isolates (63) and stock cultures (32)--consisting of: M. tuberculosis (19), M. bovis (5), M. kansasii (15), M. marinum (4), M. simiae (3), M. scrofulaceum (16), M. gordonae (6), M. szulgai (6), M. flavescens (1), M. gastri (1), M. intracellulare (6), M. fortuitum-chelonei complex (12), and M. smegmatis (1)--were tested for neat urease activity by Bactec radiometry. Mycobacterial isolates (50-100 mg wet weight) were incubated at 35 degrees C for 30 minutes with microCi14C-urea. Urease-positive mycobacteria gave Bactec growth index (GI) values greater than 100 units, whereas urease-negative species gave values less than 10 GI units. Eighty-three isolates possessing neat urease activity were heated at 80 degrees C for 30 minutes followed by incubation at 35 degrees C for 30 minutes with 1 microCi14C-urea. Mycobacterium tuberculosis-bovis complex demonstrated heat-stable urease activity (GI more than 130 units) and could be distinguished from mycobacteria other than tuberculosis (MOTT), which gave GI values equal to or less than 40 units

  13. A new relative radiometric consistency processing method for change detection based on wavelet transform and a low-pass filter

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The research purpose of this paper is to show the limitations of the existing radiometric normalization approaches and their disadvantages in change detection of artificial objects by comparing the existing approaches,on the basis of which a preprocessing approach to radiometric consistency,based on wavelet transform and a spatial low-pass filter,has been devised.This approach first separates the high frequency information and low frequency information by wavelet transform.Then,the processing of relative radiometric consistency based on a low-pass filter is conducted on the low frequency parts.After processing,an inverse wavelet transform is conducted to obtain the results image.The experimental results show that this approach can substantially reduce the influence on change detection of linear or nonlinear radiometric differences in multi-temporal images.

  14. Utilization of radiometric method in evaluation of wear on human dental enamel in vitro by dental porcelain glazed and polished

    International Nuclear Information System (INIS)

    Adachi, Lena Katekawa; Campos, Tomie Nakakuki de; Adachi, Eduardo Makoto

    2005-01-01

    The dental porcelain is a material commonly used in prosthesis. Disadvantages of dental porcelain use include possibility to cause tooth or dental materials wear. Before its use in the mouth, surfaces are treated with polishing and/or glazing. This research used the radiometric method to verify the influence of these surface treatments on the porcelains of commercial brands: Ceramco II, Noritake and Finesse. This method was originally developed for dentifrice abrasiveness evaluation. Five specimens of dental enamel and 10 specimens of each porcelain (5 glazed, 5 polished) were used. The dental enamel was flattened and irradiated with neutrons from the IEA-R1 (IPEN/CNEN) nuclear reactor. Then it was weared by each porcelain in sliding motion, with water. After 2,500 cycles for each porcelain specimen, the released enamel residue was measured. The enamel wear was evaluated by measuring beta activity of 32 P transferred to water from the irradiated tooth. Results varied from 2.57 to 5.81 μg of enamel /mm 2 weared surface. There was no statistical difference (α=0.05) between dental enamel wear caused by the same porcelains glazed or polished. The results suggest that adequate surface finishing depend on the type of dental porcelain. (author)

  15. [Rapid prototyping: a very promising method].

    Science.gov (United States)

    Haverman, T M; Karagozoglu, K H; Prins, H-J; Schulten, E A J M; Forouzanfar, T

    2013-03-01

    Rapid prototyping is a method which makes it possible to produce a three-dimensional model based on two-dimensional imaging. Various rapid prototyping methods are available for modelling, such as stereolithography, selective laser sintering, direct laser metal sintering, two-photon polymerization, laminated object manufacturing, three-dimensional printing, three-dimensional plotting, polyjet inkjet technology,fused deposition modelling, vacuum casting and milling. The various methods currently being used in the biomedical sector differ in production, materials and properties of the three-dimensional model which is produced. Rapid prototyping is mainly usedforpreoperative planning, simulation, education, and research into and development of bioengineering possibilities.

  16. ESTIMATE OF THE HEAVY MINERAL-CONTENT IN SAND AND ITS PROVENANCE BY RADIOMETRIC METHODS

    NARCIS (Netherlands)

    DEMEIJER, RJ; LESSCHER, HME; SCHUILING, RD; ELBURG, ME

    1990-01-01

    A comparison has been made of the traditional gravimetric method for measuring the heavy mineral mass fraction in sand with a method based on the emission of gamma-rays from the uranium and thorium series by radiogenic heavy-minerals. The comparision reveals that beach sand along the Dutch coast may

  17. Detection of circulating immune complexes by Raji cell assay: comparison of flow cytometric and radiometric methods

    International Nuclear Information System (INIS)

    Kingsmore, S.F.; Crockard, A.D.; Fay, A.C.; McNeill, T.A.; Roberts, S.D.; Thompson, J.M.

    1988-01-01

    Several flow cytometric methods for the measurement of circulating immune complexes (CIC) have recently become available. We report a Raji cell flow cytometric assay (FCMA) that uses aggregated human globulin (AHG) as primary calibrator. Technical advantages of the Raji cell flow cytometric assay are discussed, and its clinical usefulness is evaluated in a method comparison study with the widely used Raji cell immunoradiometric assay. FCMA is more precise and has greater analytic sensitivity for AHG. Diagnostic sensitivity by the flow cytometric method is superior in systemic lupus erythematosus (SLE), rheumatoid arthritis, and vasculitis patients: however, diagnostic specificity is similar for both assays, but the reference interval of FCMA is narrower. Significant correlations were found between CIC levels obtained with both methods in SLE, rheumatoid arthritis, and vasculitis patients and in longitudinal studies of two patients with cerebral SLE. The Raji cell FCMA is recommended for measurement of CIC levels to clinical laboratories with access to a flow cytometer

  18. A new method for rapid Canine retraction

    Directory of Open Access Journals (Sweden)

    "Khavari A

    2001-06-01

    Full Text Available Distraction osteogenesis method (Do in bone lengthening and rapid midpalatal expansion have shown the great ability of osteognic tissues for rapid bone formation under distraction force and special protocol with optimum rate of one millimeter per day. Periodontal membrane of teeth (PDM is the extension of periostium in the alveolar socked. Orthodontic force distracts PDM fibers in the tension side and then bone formation will begin.Objects: Rapid retraction of canine tooth into extraction space of first premolar by DO protocol in order to show the ability of the PDM in rapid bone formation. The other objective was reducing total orthodontic treatment time of extraction cases.Patients and Methods: Tweleve maxillary canines in six patients were retracted rapidly in three weeks by a custom-made tooth-born appliance. Radiographic records were taken to evaluate the effects of heavy applied force on canine and anchorage teeth.Results: Average retraction was 7.05 mm in three weeks (2.35 mm/week. Canines rotated distal- in by mean 3.5 degrees.Anchorage loss was from 0 to 0.8 mm with average of 0.3 mm.Root resorption of canines was negligible, and was not significant clinically. Periodontium was normal after rapid retraction. No hazard for pulp vitality was observed.Discussion: PDM responded well to heavy distraction force by Do protocol. Rapid canine retraction seems to be a safe method and can considerabely reduce orthodontic time.

  19. The role of radiometric dating method in field of the archaeology and geology

    International Nuclear Information System (INIS)

    Wisjachudin Faisal

    2009-01-01

    The role of radiocarbon dating method in the field of geology and archaeology and 210 Pb dating in the field of geology has been done. Radiocarbon dating method is a dating method with a maximum age restriction is 45,000 years old. This study is to review dating methods by using synthesis process that uses radioactive carbon ( 14 C) in the sample which is converted to benzene ( 14 C 6 H 6 ) and counted by liquid scintillation counter, while 210 Pb dating method is that dating based on the measurement of 210 Pb activity. This dating is special for sediments sample, with the maximum age of 150 years old. Some samples in the environment around the archaeological research and the geological site have been successfully carried out by radiocarbon dating analysis. Radiocarbon dating can also provide data as a contribution to support research on paleotsunami, so it can be used to estimate probability of the occurrence of tsunami in the future, while for 210 Pb method dating has done research on the sedimentation rate as well as research on the existence of harmful algal (harmful algal bloom, HAB) sample in the sediments which is very dangerous to the environment and has been examined in certain areas. From the results of the study indicate that radiocarbon dating which based on the counting of the activity of 14 C, in the future experts of radiocarbon dating is prefer to use of “modern” radiocarbon dating or radiocarbon dating by using mass spectrometry based on cyclotron method, because samples needed and standard deviation of the results relatively much smaller. (author)

  20. Evaluation and quality control of radiometric and spectrometric methods used in LVRA of Cuba CPHR

    International Nuclear Information System (INIS)

    Perez, Danyl; Prendes, Miguel; Fernandez, Isis M.; Gonzalez, Leidy

    1997-01-01

    The Surveillance Radiological Environmental Laboratory of the Center for Hygiene and Radiation Protection of Cuba, has developed a quality assurance system for the analytical services that it offers. The laboratory has designed and implemented a statistical control program for some measurements of standard samples and certificate reference materials. Statistical tests were used to determine the deviation of experimental results from the certificates ones. The results statistical analysis showed that the used methods are precise and exact in agreement with the requirements demanded for the measurements currently made in the laboratory. As a result a methodology for quality assurance of described methods was established and this experience is applicable to other analytical methods in the laboratory. (author). 15 refs., fig., 3 tabs

  1. A method for unsupervised change detection and automatic radiometric normalization in multispectral data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Canty, Morton John

    2011-01-01

    Based on canonical correlation analysis the iteratively re-weighted multivariate alteration detection (MAD) method is used to successfully perform unsupervised change detection in bi-temporal Landsat ETM+ images covering an area with villages, woods, agricultural fields and open pit mines in North...... to carry out the analyses is available from the authors' websites....

  2. Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements

    Science.gov (United States)

    Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves

    2018-05-01

    Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity

  3. X-ray radiometric method of ore quality monitoring during mining

    International Nuclear Information System (INIS)

    Ivanyukovich, G.A.

    1979-01-01

    The method is basically applied for sampling ore deposits, mainly of nonferrous and rare metals. It can be used for determining one, two or three elements in the deposit. In the USSR, the method has so far been used in Far East tin deposits and in the North Caucasus tungsten-molybdenum deposit. It is used for the analysis of boreholes, shaft walls, mined ore and ore material intended for enriching. The instruments used include single-channel gamma spectrometers using scintillation or proportional counters as detectors. Logging instruments include dual-channel spectrometers featuring automatic gain control and data processing devices. The instruments are designed for separating elements with atomic numbers 19 to 88 from mine wall materials and with atomic numbers 26 to 88 in boreholes at concentrations exceeding 0.1% and 0.01% for tin and silver, respectively. The economic benefit is shown of the introduction of the method using the Sadon lead-zinc plant and Khrustalnensk ore treatment plant as examples. (H.S.)

  4. Comparative study of gamma-ray logging and radiometric core assay of boreholes in block-I of Tummalapalle area, Cuddapah District, Andhra Pradesh using statistical methods

    International Nuclear Information System (INIS)

    Sreenivasa Reddy, M.; Mandal, G.; Bhaumik, B.K.

    2012-01-01

    A comparative study has been carried out between gamma-ray logging and radiometric core assay data of boreholes in Block-I of Tummalapalle area, South Cuddapah Basin, Andhra Pradesh using statistical methods. The product of average grade (in %eU 3 O 8 ) and thickness (in m) of uranium mineralization has been used for this purpose. The outcome of statistical analysis revealed a strong relation between gamma-ray logging and radiometric core assay data. Slope of the line is close to 1.0 and intercept is not different from 0.0. It ensures homogeneity of uranium ore distribution in the host rock. The calculated value from t-test is well within the limit and ensures the negligibility in the difference of means. This indicates that either of the data can be used for ore reserve calculation. (author)

  5. A scoping review of rapid review methods.

    Science.gov (United States)

    Tricco, Andrea C; Antony, Jesmin; Zarin, Wasifa; Strifler, Lisa; Ghassemi, Marco; Ivory, John; Perrier, Laure; Hutton, Brian; Moher, David; Straus, Sharon E

    2015-09-16

    Rapid reviews are a form of knowledge synthesis in which components of the systematic review process are simplified or omitted to produce information in a timely manner. Although numerous centers are conducting rapid reviews internationally, few studies have examined the methodological characteristics of rapid reviews. We aimed to examine articles, books, and reports that evaluated, compared, used or described rapid reviews or methods through a scoping review. MEDLINE, EMBASE, the Cochrane Library, internet websites of rapid review producers, and reference lists were searched to identify articles for inclusion. Two reviewers independently screened literature search results and abstracted data from included studies. Descriptive analysis was conducted. We included 100 articles plus one companion report that were published between 1997 and 2013. The studies were categorized as 84 application papers, seven development papers, six impact papers, and four comparison papers (one was included in two categories). The rapid reviews were conducted between 1 and 12 months, predominantly in Europe (58 %) and North America (20 %). The included studies failed to report 6 % to 73 % of the specific systematic review steps examined. Fifty unique rapid review methods were identified; 16 methods occurred more than once. Streamlined methods that were used in the 82 rapid reviews included limiting the literature search to published literature (24 %) or one database (2 %), limiting inclusion criteria by date (68 %) or language (49 %), having one person screen and another verify or screen excluded studies (6 %), having one person abstract data and another verify (23 %), not conducting risk of bias/quality appraisal (7 %) or having only one reviewer conduct the quality appraisal (7 %), and presenting results as a narrative summary (78 %). Four case studies were identified that compared the results of rapid reviews to systematic reviews. Three studies found that the conclusions between

  6. Comparison of thiaminase activity in fish using the radiometric and 4-nitrothiophenol colorimetric methods

    Science.gov (United States)

    Honeyfield, D.C.; Hanes, J.W.; Brown, L.; Kraft, C.E.; Begley, T.P.

    2010-01-01

    Thiaminase induced thiamine deficiency occurs in fish, humans, livestock and wild animals. A non-radioactive thiaminase assay was described in 2007, but a direct comparison with the radioactive 14C-thiamine method which has been in use for more than 30years has not been reported. The objective was to measure thiaminase activity in forage fish (alewife Alosa pseudoharengus, rainbow smelt Osmerus mordax, and slimy sculpin Cottus cognatus) consumed by predators that manifest thiamine deficiency using both methods. Modifications were made to the colorimetric assay to improve repeatability. Modification included a change in assay pH, enhanced sample clean-up, constant assay temperature (37??C), increase in the concentration of 4-nitrothiophenol (4NTP) and use of a spectrophotometer fitted with a 0.2cm cell. A strong relationship between the two assays was found for 51 alewife (R2=0.85), 36 smelt (R2=0.87) and 20 sculpin (R2=0.82). Thiaminase activity in the colorimetric assay was about 1000 times higher than activity measured by the radioactive method. Application of the assay to fish species from which no thiaminase activity has previously been reported resulted in no 4NTP thiaminase activity being found in bloater Coregonus hoyi, lake trout Salvelinus namaycusch, steelhead trout Oncorhynchus mykiss or Chinook salmon Oncorhynchus tshawytscha. In species previously reported to contain thiaminase, 4NTP thiaminase activity was measured in bacteria Paenibacillus thiaminolyticus, gizzard shad Dorosoma cepedianum, bracken fern Pteridium aquilinum, quagga mussel Dreissena bugensis and zebra mussels D. polymorpha. ?? 2010.

  7. Test and standardization of a radiometric method for free testosterone assay in biological materials

    International Nuclear Information System (INIS)

    Mathor, M.B.

    1983-01-01

    The principles of equilibrium dialysis technique using semi-permeable cellulose membranes were analysed and a modification was presented for the calculation of the unbound or free fraction of plasma steroids. The results were compared with those from the classical way of calculation used in the equilibrium dialysis technique in which it is necessary to include the change in weight of the dialysis bags. Technical aspects of the method were studied such as weight variation of the dialysis bags during dialysis, comparison of the results obtained using multiple plasma dilutions or one dilution only and comparing serum and plasma. The results obtained with the multiple dilutions technique were similar to those with non-diluted plasma while significantly different from those using one dilution only. The operational characteristics of the method were evaluated showing its specificity at least by the dilution test, besides being precise considering intra and interassay reproductibility. The mean + - s.d. of the percent free testosterone levels were 2.57 + - 0.45% and 1.67 + - 0.30% for males and females at the mid-follicular phase respectively. (Author) [pt

  8. New developments in radiometrics and mass spectrometry methods for radionuclide analysis of environmental samples

    International Nuclear Information System (INIS)

    Povinec, P.P.; LaRosa, J.J.; Lee, S.H.; Wyse, E.

    2002-01-01

    The radionuclide levels observed at present in the environment are very low, therefore high sensitive analytical systems are required for carrying out environmental investigations. One very important recent development in analytical techniques for low-level activity measurements is the production of large volume HPGe detectors (up to 200% relative efficiency to 75 mm diameter x 75 mm long NaI (Tl) crystals). Their high efficiency and excellent energy resolution permit the analyses of various gamma-emitters in composite samples selectively and very often non-destructively (e.g. in sea sediments). However, this technique is restricted to gamma-emitters only (e.g. for 7 Be, 40 K, 54 Mn, 60 Co, 137 Cs, 210 Pb, etc.). Other radionuclides frequently found in the marine environment are the pure beta-emitters, like 3 H, 14 C, 32 Si, 32 P, 90 Sr, 241 Pu, etc., where mainly liquid scintillation counting has made great improvements in recent years. However, for some of these radionuclides mass spectrometry methods represent a real breakthrough in low-level counting, e.g. 3 He in-growth mass spectrometry for 3 H, or accelerator mass spectrometry (AMS) for 14 C

  9. Limulus test for pyrogens and radiometric sterility tests on radiopharmaceuticals. Part of a coordinated programme

    International Nuclear Information System (INIS)

    Gopal, N.G.S.

    1976-10-01

    Sterility testing of radiopharmaceuticals prepared at BARC were carried out using the radiometric technique (Radiometric detection of the metabolic product 14 Co 2 ). Batches of different radiopharmaceuticals were tested for pyrogen using the limulus lysate method and the results were compared with the rabbit method. The results of sterility test on 202 batches of 19 different radiopharmaceuticals show that the radiometric method can be used for sterility testing of radiopharmaceuticals labelled with 35 S, 51 Cr, 57 Co, 59 Fe, 82 Br, 86 Rb, sup(99m)Tc, sup(113m)In, 125 I and 169 Yb. The radiometric test proves to be more rapid than the conventional one for the sterility testing of such radiopharmaceuticals. Detection time is between 6-21 hours. In the case of 131 I-labelled radiopharmaceuticals and in the case of chlormerodrin-Hg-203, it was found an interference due to volatile species (sup(131m)Xe in the case of 131 I and some volatile mercury form in the case of chlormerodrin). In these cases it would be possible to carry out the radiometric sterility test after separation of the microorganisms from the radioactive material (by filtration). The limulus lysate method can be employed for control of various pyrogen-prone raw materials and radiopharmaceuticals. Such method is the only method at present available for detecting the low level pyrogen contamination in intrathecal injections. The limulus test is more rapid than the rabbit test

  10. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples

    Science.gov (United States)

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  11. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples.

    Science.gov (United States)

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  12. Automated radiometric detection of bacteria

    International Nuclear Information System (INIS)

    Waters, J.R.

    1974-01-01

    A new radiometric method called BACTEC, used for the detection of bacteria in cultures or in supposedly sterile samples, was discussed from the standpoint of methodology, both automated and semi-automated. Some of the results obtained so far were reported and some future applications and development possibilities were described. In this new method, the test sample is incubated in a sealed vial with a liquid culture medium containing a 14 C-labeled substrate. If bacteria are present, they break down the substrate, producing 14 CO 2 which is periodically extracted from the vial as a gas and is tested for radioactivity. If this gaseous radioactivity exceeds a threshold level, it is evidence of bacterial presence and growth in the test vial. The first application was for the detection of bacteria in the blood cultures of hospital patients. Data were presented showing typical results. Also discussed were future applications, such as rapid screening for bacteria in urine industrial sterility testing and the disposal of used 14 C substrates. (Mukohata, S.)

  13. Statistical techniques applied to aerial radiometric surveys (STAARS): series introduction and the principal-components-analysis method

    International Nuclear Information System (INIS)

    Pirkle, F.L.

    1981-04-01

    STAARS is a new series which is being published to disseminate information concerning statistical procedures for interpreting aerial radiometric data. The application of a particular data interpretation technique to geologic understanding for delineating regions favorable to uranium deposition is the primary concern of STAARS. Statements concerning the utility of a technique on aerial reconnaissance data as well as detailed aerial survey data will be included

  14. Application of radiometric method to determine P/sub 2/O/sub 5/ at Verkhnekamsk phosphorite mine

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, M A; Terent' ev, E P; Anderzhanov, V N

    1981-01-01

    Correlations between P/sub 2/O/sub 5/ content and natural radioactivity in phosphorites of Vjatsko-Kamsk deposits and products of their enrichment, are considered. A scheme of an installation to conduct continuous radiometric control of P/sub 2/O/sub 5/ content in the pulp flow is presented. The results of the installation test at Verkhnekamsk phosphorite mine to control P/sub 2/O/sub 5/ content in the flow final rejects are given.

  15. Experimental study on rapid embankment construction methods

    International Nuclear Information System (INIS)

    Hirano, Hideaki; Egawa, Kikuji; Hyodo, Kazuya; Kannoto, Yasuo; Sekimoto, Tsuyoshi; Kobayashi, Kokichi.

    1982-01-01

    In the construction of a thermal or nuclear power plant in a coastal area, shorter embankment construction period has come to be called for recently. This tendency is remarkable where construction period is limited due to meteorological or sea conditions. To meet this requirement, the authors have been conducting basic experimental studies on two methods for the rapid execution of embankment construction, that is, Steel Plate Cellular Bulkhead Embedding Method and Ship Hull Caisson Method. This paper presents an outline of the results of the experimental study on these two methods. (author)

  16. Rapid method for measuring protease activity in milk using radiolabeled casein

    International Nuclear Information System (INIS)

    Christen, G.L.

    1987-01-01

    A rapid means to detect the presence of protease activity in raw milk could be useful in predicting keeping ability of products made from that milk. A 30-min assay has been developed and compared with three other methods of detecting protease. Casein, [methyl- 14 C]-methylated-alpha was purchased from a radioisotope supplier. Concentrations of substrate from 2 to 20 nCi gave counts per minute, which increased linearly when counted with the Charm analyzer. There was not a significant difference in counting times of 10, 20, or 30 min. A mixture of sodium acetate and acetic acid precipitated nonhydrolyzed substrate with an efficiency of 97%. Comparison of the [ 14 C] casein assay, a casein fluorescein isothiocyanate assay, trinitrobenzenesulfonic acid procedure, and the Hull procedure using protease from psychrotrophic bacteria revealed that the [ 14 C] casein and casein fluorescein isothiocyanate methods were roughly equivalent and that the radiometric procedure was 10 times more sensitive than the trinitrobenzenesulfonic acid assay. The radiometric procedure was approximately 10(4) times more sensitive than the Hull procedure. The [ 14 C] casein and casein fluorescein isothiocyanate methods were similar in time required, about 30 min, while the trinitrobenzenesulfonic acid assay and Hull method required about 1 h plus reagent preparation time. The [ 14 C] casein procedure was most expensive per test; the other three were cheaper and similar to each other in cost

  17. Rapid Radiochemical Methods for Asphalt Paving Material ...

    Science.gov (United States)

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  18. Survey of methods for rapid spin reversal

    International Nuclear Information System (INIS)

    McKibben, J.L.

    1980-01-01

    The need for rapid spin reversal technique in polarization experiments is discussed. The ground-state atomic-beam source equipped with two rf transitions for hydrogen can be reversed rapidly, and is now in use on several accelerators. It is the optimum choice provided the accelerator can accept H + ions. At present all rapid reversal experiments using H - ions are done with Lamb-shift sources; however, this is not a unique choice. Three methods for the reversal of the spin of the atomic beam within the Lamb-shift source are discussed in order of development. Coherent intensity and perhaps focus modulation seem to be the biggest problems in both types of sources. Methods for reducing these modulations in the Lamb-shift source are discussed. The same Lamb-shift apparatus is easily modified to provide information on the atomic physics of quenching of the 2S/sub 1/2/ states versus spin orientation, and this is also discussed. 2 figures

  19. An in vitro study of dental enamel wear by restorative materials using radiometric method; Estudo in vitro do desgaste do esmalte dental pelos materiais restauradores utilizando metodo radiometrico

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Lena Katekawa

    2000-07-01

    There is an increasing demand and interest to study the dental materials wear as well as about the abrasion effect on antagonistic teeth. Due to the fact that the existent restorative materials have no specifications about their abrasiveness, it is necessary the establishment of degrees of comparison among them to support clinical application. In this work, the radiometric method was applied to study the enamel wear caused by another enamel and by restorative materials (Ceramco II, Noritake and Finesse porcelains, Artglass and Targis). The dental enamel made radioactive by irradiation at the IEA-R1m nuclear research reactor under a thermal neutron flux was submitted to wear in a machine which allows sliding motion of an antagonistic surface in contact with this radioactive enamel. The enamel wear was evaluated by measuring beta activity of {sup 32}P transferred to water from this irradiated tooth. Results obtained indicated that dental porcelains cause pronounced enamel wear when compared with that provoked by another enamel or by resin materials. Resin materials caused less enamel wear than another enamel. Vickers microhardness data obtained for antagonistic materials showed a correlation with the wear caused to the enamel. This study allowed to conclude that the radiometric method proposed can be used satisfactorily in the evaluation of enamel wear by restorative materials. This method presents advantages due to quick responses and ease of analyses There is (author)

  20. Training course on radiometric prospecting techniques

    International Nuclear Information System (INIS)

    1979-01-01

    A training course on radiometric prospecting techniques was presented by the Atomic Energy Board in collaboration with the South African Geophysical Association and the Geological Society of South Africa. Various aspects related to uranium prospecting were discussed e.g. the uranium supply and demand position, the basic physics of radioactivity, uranium geochemistry, mineralogy and mobility, the instrumentation and techniques used in uranium exploration, for example, borehole logging, radon emanometry and airborne radiometric surveys and also data processing and interpretation methods

  1. Broadband Radiometric LED Measurements

    OpenAIRE

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(��) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irr...

  2. Method for improving the use of PASCO brand spectrophotometer using DataStudio program applied to radiometric surveys for LAFTLA

    International Nuclear Information System (INIS)

    Bolanos Rodriguez, Gary

    2008-01-01

    Escuela de Ingenieria Electrica at the Universidad de Costa Rica has developed a procedure for the improved use of a PASCO brand Spectrophotometer of the Laboratorio de Fotonica y Tecnologia Laser Aplicada. The program has used DataStudio for the application in radiometric surveys in LAFTLA. Important conclusions have been obtained by the assembly of optical experiments, software and data collection and analysis, such as the behavior of a emitting source radiation known as black body and its relation to the temperature, wavelength and intensity of light. The user guide has been detailed exposing calibrations of the sensors, the definition of constants needed for obtaining parameters and assembly and commissioning of the equipment. (author) [es

  3. A new rapid method for isolating nucleoli.

    Science.gov (United States)

    Li, Zhou Fang; Lam, Yun Wah

    2015-01-01

    The nucleolus was one of the first subcellular organelles to be isolated from the cell. The advent of modern proteomic techniques has resulted in the identification of thousands of proteins in this organelle, and live cell imaging technology has allowed the study of the dynamics of these proteins. However, the limitations of current nucleolar isolation methods hinder the further exploration of this structure. In particular, these methods require the use of a large number of cells and tedious procedures. In this chapter we describe a new and improved nucleolar isolation method for cultured adherent cells. In this method cells are snap-frozen before direct sonication and centrifugation onto a sucrose cushion. The nucleoli can be obtained within a time as short as 20 min, and the high yield allows the use of less starting material. As a result, this method can capture rapid biochemical changes in nucleoli by freezing the cells at a precise time, hence faithfully reflecting the protein composition of nucleoli at the specified time point. This protocol will be useful for proteomic studies of dynamic events in the nucleolus and for better understanding of the biology of mammalian cells.

  4. Multielemental X-ray radiometric analysis of ferromanganese concretions

    International Nuclear Information System (INIS)

    Metelev, A.Yu.; Grigor'ev, A.I.; Rakita, K.A.; Mamaenko, M.V.; Ivanenko, V.V.

    1994-01-01

    Ferromanganese concretions are promising mineral resources of the ocean. Most often, they are analyzed by atomic-absorption, spectra, X-ray spectral, neutron-activation, and X-ray radiometric methods. Note that X-ray radiometric analysis (XRRA) allows the sufficiently rapid determination of a great number of elements in ferromanganese concretions. The possibility of using XRRA with saturated and thin layers was shown; however, the data on the precision and accuracy of the technique was not given. The purpose of this study is to evaluate the basic performance characteristics of the multielemental X-ray radiometric analysis of ferromanganese concretions (Pacific Ocean). Determinations for K,Ca and Ti content were made using a 55 Fe source and for Mn, Fe, Ni, Cu, Zn, Pb, Sr, Y, Zr, Nb, and Mo contents by using a 109 Cd source. The precision and accuracy of the method was investigated by using reference concretions; it was found the confidence intervals overlap for all of the elements except Ca and Pb. The relative standard deviation was 1-5%, indicating the high precision of the method. The described technique is successfully used on research vessels of the Far East Division of the Russian Academy of Sciences and in South Pacific Ocean geological expeditions of PO open-quotes Dal'morgeologiyaclose quotes

  5. Radiometric determination of anionic surfactants by two-phase titration method with the use of sup(131)I-Rose Bengal as indicator

    International Nuclear Information System (INIS)

    Lengyel, J.; Krtil, J.

    1986-01-01

    A radiometric variant of the two-phase titration method for the determination of anionic surfactants of nonsoapy type is described. The method is based on the titration of an anionic surfactant with Septonex in alkaline medium in the presence of sup(131)I-Rose Bengal (sup(131)I-RB). The ion associates are extracted into chloroform. The equivalence point is determined graphically from the activity of sup(131)I-RB-Septonex associate, which is formed after the consumption of the anionic surfactant and passes into the organic phase. The influence of sup(131)I-RB amount, pH of the titrated medium and of soap on the precision of anionic surfactant determination was studied. The detection limit is 2.88 μg sodium n-dodecylsulfate in 10 ml of sample. (author)

  6. Computerized method for rapid optimization of immunoassays

    International Nuclear Information System (INIS)

    Rousseau, F.; Forest, J.C.

    1990-01-01

    The authors have developed an one step quantitative method for radioimmunoassay optimization. The method is rapid and necessitates only to perform a series of saturation curves with different titres of the antiserum. After calculating the saturation point at several antiserum titres using the Scatchard plot, the authors have produced a table that predicts the main characteristics of the standard curve (Bo/T, Bo and T) that will prevail for any combination of antiserum titre and percentage of sites saturation. The authors have developed a microcomputer program able to interpolate all the data needed to produce such a table from the results of the saturation curves. This computer program permits also to predict the sensitivity of the assay at any experimental conditions if the antibody does not discriminate between the labeled and the non labeled antigen. The authors have tested the accuracy of this optimization table with two in house RIA systems: 17-β-estradiol, and hLH. The results obtained experimentally, including sensitivity determinations, were concordant with those predicted from the optimization table. This method accerelates and improves greatly the process of optimization of radioimmunoassays [fr

  7. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  8. A simple radiometric in vitro assay for acetylcholinesterase inhibitors

    International Nuclear Information System (INIS)

    Guilarte, T.R.; Burns, H.D.; Dannals, R.F.; Wagner, H.N. Jr.

    1983-01-01

    A radiometric method for screening acetylcholinesterase inhibitors has been described. The method is based on the production of [ 14 C]carbon dioxide from the hydrolysis of acetylcholine. The inhibitory concentration at 50% (IC50) values for several known acetylcholinesterase inhibitors were in agreement with literature values. The new radiometric method is simple, inexpensive, and has the potential for automation

  9. Broadband radiometric LED measurements

    Science.gov (United States)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  10. Radiometric well logging instruments

    International Nuclear Information System (INIS)

    Davydov, A.V.

    1975-01-01

    The technical properties of well instruments for radioactive logging used in the radiometric logging complexes PKS-1000-1 (''Sond-1'') and PRKS-2 (''Vitok-2'') are described. The main features of the electric circuit of the measuring channels are given

  11. Automation of radiometric testing

    International Nuclear Information System (INIS)

    Chekalin, A.S.; Temnik, A.K.; Butakova, G.E.; Goncharov, V.I.

    1983-01-01

    The main prerequisites for creation of automatic systems of radiometric testing as the means to increase the testing objectivity and quality have been considered, principles of their design being developed. The operating system is described for testing complex configuration products using RD-10R gamma flow detector as a sensor of initial information

  12. Radiometric sampling of bucked copper-nickel ores for determining chemical composition

    International Nuclear Information System (INIS)

    Komlev, V.N.; Eliseev, G.I.

    1978-01-01

    Presented are the results and the technique of experimental-methodical works on radiometric sampling of bucked copper-nickel ores for determining chemical composition with their selection and analysis by the neutron-gamma method and by the gamma-gamma method. The error is estimated according to the chosen conditions of sampling. It is found that the gamma-gamma method being more rapid but less accurate is applied for rapid control of ore current, whereas the neutron-gamma method is applied for quality control of ores extracted

  13. Determination of molybdenite leaching degree by x-ray radiometric analysis

    International Nuclear Information System (INIS)

    Bibinov, S.A.; Gladyshev, V.P.; Yarmolik, A.S.; Kim, A.Ch.; Sokur, N.P.

    1984-01-01

    A express chemical X-ray radiometric method for determination of leaching degree and analysis of molybdenite products is developed. The method comprises chemical preparation and the following X-ray radiometric determination of molyb bdenum. Total duration of the analysis is 1-1.5 h. The best reproductivity is btained at X-ray radiometric analysis as compared with the chemical one

  14. Development of radiometric methods for the determination of enzyme activities of iodothyronine deiodinases. Effect of the antidepressant fluoxetine on type 1, 2 and 3 deiodinase activities in the rat brain

    International Nuclear Information System (INIS)

    Pavelka, Stanislav

    2010-01-01

    The objectives of the present study were to establish valid assay conditions for measurement of the types 1, 2, and 3 (Dl, D2, and D3, respectively) iodothyronine deiodinases (IDs) activities, and to use the radiometric enzyme assays especially to follow the effects of antidepressant drug fluoxetine (Prozac) on the metabolism of thyroid hormones (TH) in the rat. In particular, the effects of subchronic administration of fluoxetine alone and in combination with 3,5,3'-triiodothyronine (T 3 ) on T 3 production and degradation in the CNS and peripheral tissues were investigated. The newly developed radiometric enzyme assays for IDs, based on the use of preferred 125 I-labeled iodothyronines as substrates, TLC separation of radioactive products from the unconsumed substrates, film-less autoradiography of radiochromatograms using storage phosphor screens, and quantification of the separated compounds with the BAS-5000 laser scanner, proved to be very sensitive and rapid and, at the same time, reliable and robust. (author)

  15. Application of microcomputer to X-ray radiometric ore separation

    International Nuclear Information System (INIS)

    Neverov, A.D.; Aleksandrov, P.S.; Kotler, N.I.

    1988-01-01

    The practical use of microcomputers as universal means for converting information for solving applied problems of X-ray radiometric ore separation method is considered. Laboratory tests of two metals - tungsten and tin manifested high efficiency of the developed system. X-ray radiometric separator software is developed

  16. A method for sensible heat flux model parameterization based on radiometric surface temperature and environmental factors without involving the parameter KB-1

    Science.gov (United States)

    Zhuang, Qifeng; Wu, Bingfang; Yan, Nana; Zhu, Weiwei; Xing, Qiang

    2016-05-01

    Sensible heat flux is a key component of land-atmosphere interaction. In most parameterizations it is calculated with surface-air temperature differences and total aerodynamic resistance to heat transfer (Rae) that is related to the KB-1 parameter. Suitable values are hard to obtain since KB-1 is related both to canopy characteristics and environmental conditions. In this paper, a parameterize method for sensible heat flux over vegetated surfaces (maize field and grass land in the Heihe river basin of northwest China) was proposed based on the radiometric surface temperature, surface resistance (Rs) and vapor pressures (saturated and actual) at the surface and the atmosphere above the canopy. A biophysics-based surface resistance model was revised to compute surface resistance with several environmental factors. The total aerodynamic resistance to heat transfer is directly calculated by combining the biophysics-based surface resistance and vapor pressures. One merit of this method is that the calculation of KB-1 can be avoided. The method provides a new way to estimate sensible heat flux over vegetated surfaces and its performance compares well to the LAS measured sensible heat and other empirical or semi-empirical KB-1 based estimations.

  17. Methods and compositions for rapid thermal cycling

    Energy Technology Data Exchange (ETDEWEB)

    Beer, Neil Reginald; Benett, William J.; Frank, James M.; Deotte, Joshua R.; Spadaccini, Christopher

    2018-04-10

    The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.

  18. Analysis of Properties of Reflectance Reference Targets for Permanent Radiometric Test Sites of High Resolution Airborne Imaging Systems

    Directory of Open Access Journals (Sweden)

    Eero Ahokas

    2010-08-01

    Full Text Available Reliable and optimal exploitation of rapidly developing airborne imaging methods requires geometric and radiometric quality assurance of production systems in operational conditions. Permanent test sites are the most promising approach for cost-efficient performance assessment. Optimal construction of permanent radiometric test sites for high resolution airborne imaging systems is an unresolved issue. The objective of this study was to assess the performance of commercially available gravels and painted and unpainted concrete targets for permanent, open-air radiometric test sites under sub-optimal climate conditions in Southern Finland. The reflectance spectrum and reflectance anisotropy and their stability were characterized during the summer of 2009. The management of reflectance anisotropy and stability were shown to be the key issues for better than 5% reflectance accuracy.

  19. Rapid Vegetative Propagation Method for Carob

    OpenAIRE

    Hamide GUBBUK; Esma GUNES; Tomas AYALA-SILVA; Sezai ERCISLI

    2011-01-01

    Most of fruit species are propagated by vegetative methods such as budding, grafting, cutting, suckering, layering etc. to avoid heterozygocity. Carob trees (Ceratonia siliqua L.) are of highly economical value and are among the most difficult to propagate fruit species. In the study, air-layering propagation method was investigated first time to compare wild and cultivated (�Sisam�) carob types. In the experiment, one year old carob limbs were air-layered on coco peat medium by wrapping with...

  20. KERNEL MAD ALGORITHM FOR RELATIVE RADIOMETRIC NORMALIZATION

    Directory of Open Access Journals (Sweden)

    Y. Bai

    2016-06-01

    Full Text Available The multivariate alteration detection (MAD algorithm is commonly used in relative radiometric normalization. This algorithm is based on linear canonical correlation analysis (CCA which can analyze only linear relationships among bands. Therefore, we first introduce a new version of MAD in this study based on the established method known as kernel canonical correlation analysis (KCCA. The proposed method effectively extracts the non-linear and complex relationships among variables. We then conduct relative radiometric normalization experiments on both the linear CCA and KCCA version of the MAD algorithm with the use of Landsat-8 data of Beijing, China, and Gaofen-1(GF-1 data derived from South China. Finally, we analyze the difference between the two methods. Results show that the KCCA-based MAD can be satisfactorily applied to relative radiometric normalization, this algorithm can well describe the nonlinear relationship between multi-temporal images. This work is the first attempt to apply a KCCA-based MAD algorithm to relative radiometric normalization.

  1. Application of a radiometric enzymic method for monitoring organophosphorus and carbamate insecticide residues in water of the Danube River

    International Nuclear Information System (INIS)

    Horvath, L.; Volford, J.; Bursics, L.; Forster, T.

    1983-01-01

    Pesticide residue analyses are conventionally based on gas chromatography. These analytic procedures include tedious extraction and clear-up manipulations prior to the actual gas chromatographic determinations. Radioenzymatic method was recently applied in a residue monitoring programme on the Danube River. The programme has demonstrated that the radioenzymatic method has many advantages as a monitoring procedure in aquatic environment. Quick information can be gained without tedious sample clear-up procedure. The anticholinesteratic pesticides and the anticholinesteratic activities can be detected

  2. Characterization of filters cartridges from the water polishing system of IEA-R1 reactor: radiometric methods

    International Nuclear Information System (INIS)

    Tessaro, Ana Paula G.; Vicente, Roberto

    2015-01-01

    The acceptance of radioactive waste in a repository depends primarily on knowledge of the radioisotopic inventory of the material, according to regulations established by regulatory agencies. The primary characterization is also a fundamental action to determine further steps in the management of the radioactive wastes. The aim of this work is to report the development of non-destructive methods for primary characterization of filters cartridges discarded as radioactive waste. The filters cartridges are used in the water polishing system of the IEA-R1 reactor retaining the particles in suspension in the reactor cooling water. The IEA-R1 is a pool type reactor with a thermal power of 5 MW, moderated and cooled with light water. It is located in the Energy and Nuclear Research Institute (IPEN-CNEN), in São Paulo, Brazil. The cartridge filters become radioactive waste when they are saturated and do not meet the required flow for the proper operation of the water polishing system. The activities of gamma emitters present in the filters are determined using gamma spectrometry, dose rate measurements and the Point Kernel Method to correlate results from both measurements. For the primary characterization, one alternative method is the radiochemical analysis of slices taken from each filter, what presents the disadvantage of higher exposures personnel and contamination risks. Another alternative method is the calibration of the measurement geometry of a gamma spectrometer, which requires the production of a standard filter. Both methods are necessary but can not be used in operational routine of radioactive waste management owing to cost and complexity. The method described can be used to determine routinely the radioactive inventory of these filters and other radioactive wastes, avoiding the necessity of destructive radiochemical analysis, or the necessity of calibrating the geometry of measurement. (author)

  3. Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Roos, Per

    2008-01-01

    application in the environmental and biological researches, these radionuclides include H-3, C-14, Cl-36, Ca-41 Ni-59,Ni-63, Sr-89,Sr-90, Tc-99, I-129, Cs-135,Cs-137, Pb-210, Ra-226,Ra-228, Np-237, Am-241, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection...

  4. Dating of the middle Palaeolithic site of Payre (Ardeche): new radiometric data (U-series and ESR methods)

    International Nuclear Information System (INIS)

    Masaoudi, H.; Falgueres, Ch.; Bahain, J.J.; Moncel, M.H.

    1997-01-01

    The site of Payre is located in Ardeche. Several archaeological layers containing lithic artefacts of Middle Palaeolithic were found. These artefacts lie associated with carbonate formations which are good chronostratigraphic markers. The U-series and ESR methods on bones and stalagmitic floors placed the human occupation between isotopic marine stages 7 and 4. (authors)

  5. Radiometric method for the determination of uranium in soil and air: single-laboratory evaluation and interlaboratory collaborative study

    International Nuclear Information System (INIS)

    Casella, V.R.; Bishop, C.T.; Glosby, A.A.

    1980-02-01

    Results of a single-laboratory evaluation and an interlaboratory collaborative study of a method for determining uranium isotopes in soil and air samples are presented. The method is applicable to 10-gram soil samples and to both glass fiber and polystyrene (Microsorban) air filter samples. Sample decomposition is accomplished with a nitric-hydrofluoric acid dissolution. After a solvent extraction step to remove most of the iron present, the uranium is isolated by anion exchange chromatography and electrodeposition. Alpha spectrometry is used to measure the uranium isotopes. Two soil samples, a glass fiber air filter sample, and a polystyrene air filter sample were used to evaluate the method for uranium concentrations ranging from a few tenths to about one hundred disintegrations per minute per sample. Tracer recoveries for the single-laboratory evaluation averaged 78%, while the tracer recoveries for the collaborative study averaged 66%. Although the precision of the collaborative study results did not approach counting statistics errors, the measured uranium concentrations for these samples agreed to within 5% of the reference concentrations when the uranium concentration was greater than one disintegration per minute per gram of soil or one disintegration per minute per air filter

  6. An alternative radiometric method for calculating the sedimentation rates: Application to an intertidal region (SW of Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Ligero, R.A., E-mail: rufino.ligero@uca.e [Departamento de Fisica Aplicada, Universidad de Cadiz, 11510 Puerto Real, Cadiz (Spain); Casas-Ruiz, M. [Departamento de Fisica Aplicada, Universidad de Cadiz, 11510 Puerto Real, Cadiz (Spain); Barrera, M. [Departamento de Medio Ambiente, CIEMAT, Madrid 28040 (Spain); Barbero, L. [Departamento de Ciencias de la Tierra, Universidad de Cadiz, 11510 Puerto Real (Spain); Melendez, M.J. [Departamento de Fisica Aplicada, Universidad de Cadiz, 11510 Puerto Real, Cadiz (Spain)

    2010-09-15

    A new method using the inventory determined for the activity of the radionuclide {sup 137}Cs, coming from global radioactive fallout has been utilised to calculate the sedimentation rates. The method has been applied in a wide intertidal region in the Bay of Cadiz Natural Park (SW Spain). The sedimentation rates estimated by the {sup 137}Cs inventory method ranged from 0.26 cm/year to 1.72 cm/year. The average value of the sedimentation rate obtained is 0.59 cm/year, and this rate has been compared with those resulting from the application of the {sup 210}Pb dating technique. A good agreement between the two procedures has been found. From the study carried out, it has been possible for the first time, to draw a map of sedimentation rates for this zone where numerous physico-chemical, oceanographic and ecological studies converge, since it is situated in a region of great environmental interest. This area, which is representative of common environmental coastal scenarios, is particularly sensitive to perturbations related to climate change, and the results of the study will allow to make short and medium term evaluations of this change.

  7. Sterility test by radiometric technique

    International Nuclear Information System (INIS)

    Faruq, Muhammad

    1980-01-01

    Sterility test of pharmaceuticals can be carried out by the application of pharmacopoeia and radiometric technique. In Indonesia the application of pharmacopoeia technique is carried out through liquid germination for aerobacteria and for fungus and yeast. Radiometric technique is applied to autotrop and heterotrop bacteria. (SMN)

  8. Radiometric geochronology of the Himalaya

    International Nuclear Information System (INIS)

    Saini, H.S.

    1982-01-01

    The radiometric age data obtained by different dating methods have been interpreted in terms of possible orogenic activities prevailing in the Himalaya. In general, the age data confirm four main events, the Precambrian, the Late Precambrian-Cambrian Assyntian (Caledonian), the Late Palaeozoic-Hercynian and the Late Cretaceous-Tertiary Himalayan orogeny. The mineral dates are particularly significant in delineating different phases of the last i.e. the Himalayan orogeny which indicates main activity of the young Himalayan metamorphism around 70 to 50 Ma and followed by a momentous phase of major uplift during 25 to 10 Ma, which was responsible for the rise of the deeper part of the Himalaya into great folds and thrust slices and the formation of nappe structures. (author)

  9. Radiometric assessment of the sensitivity to antituberculotics of Mycobacterium avium-intracellulare and Mycobacterium xenopi

    International Nuclear Information System (INIS)

    Kubin, M.; Lindholm-Levy, P.; Heifets, L. B.

    1994-01-01

    The macrodilution radiometric method using Middlebrook's 7H12 liquid medium enriched with 14 C-palmitic acid, where the growth activity is monitored by measuring liberated 14 CO 2 , was applied to 25 strains of the Mycobacterium avium complex and to 20 strains of Mycobacterium xenopi to determine the minimal inhibitory concentrations of the following chemotherapeutical agents: ciprofloxacine, clofazimine, rifampin, cycloserine, kanamycin, etionamide, ethambutol, and amikacin. In the case of the M. avium complex, slightly or completely resistant strains were found for the majority of drugs. The sensitive strain proportion was highest with clofazimine and amikacin. The M. xenopis strains exhibited generally lower minimal inhibitory concentrations than the avian mycobacteria for all drugs except for cycloserine and ethambutol. The radiometric method using the BACTEC system was found suitable for the determination of the sensitivity of mycobacteria to chemotherapeutic agents: the results are obtained rapidly, within 8 days following inoculation, and the minimal inhibitory concentrations can be evaluated quantitatively. 1 tab., 8 refs

  10. An alternative method for the estimation of sedimentation rates using radiometric measurements in an intertidal region (sw of spain)

    Science.gov (United States)

    Ligero, Rufino; Casas-Ruiz, Melquiades; Barrera, Manuel; Barbero, Luis

    2010-05-01

    The techniques for the direct measurement of the sedimentation rate are reliable but slow and imprecise, given that the time intervals of measurement cannot be very long. Consequently it is an extremely laborious task to obtain a representative map of the sedimentation rates and such maps are available for very few zones. However, for most environmental studies, it is very important to know the sedimentation rates. The high degree of accuracy of the gamma spectrometric techniques together with the application of the model describes in this work, has allowed the determination of the sedimentation rates in a wide spatial area such of the Bay of Cadiz to be obtained with precision and consuming considerably less time in comparison to the traditional techniques. Even so, the experimental conditions required for the sample cores are fairly restrictive, and although the radiological method provides a quantitative advance in measurement, the experimental difficulty in the execution of the study is not greatly diminished. For this reason, a second model has been derived based on the measurement of the inventory, which offers economies in time and financial cost, and which allows the sedimentation rate in a region to be determined with satisfactory accuracy. Furthermore, it has been shown that the application of this model requires a precise determination of 137Cs inventories. The sedimentation rates estimated by the 137Cs inventory method ranged from 0.26 cm/year to 1.72 cm/year. The average value of the sedimentation rate obtained is 0.59 cm/year, and this rate has been compared with those resulting from the application of the 210Pb dating technique. A good agreement between the two procedures has been found. From the study carried out, it has been possible for the first time, to draw a map of sedimentation rates for this zone where numerous physical-chemical, oceanographic and ecological studies converge, since it is situated in a region of great environmental interest

  11. [A new method of fabricating photoelastic model by rapid prototyping].

    Science.gov (United States)

    Fan, Li; Huang, Qing-feng; Zhang, Fu-qiang; Xia, Yin-pei

    2011-10-01

    To explore a novel method of fabricating the photoelastic model using rapid prototyping technique. A mandible model was made by rapid prototyping with computerized three-dimensional reconstruction, then the photoelastic model with teeth was fabricated by traditional impression duplicating and mould casting. The photoelastic model of mandible with teeth, which was fabricated indirectly by rapid prototyping, was very similar to the prototype in geometry and physical parameters. The model was of high optical sensibility and met the experimental requirements. Photoelastic model of mandible with teeth indirectly fabricated by rapid prototyping meets the photoelastic experimental requirements well.

  12. Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens

    International Nuclear Information System (INIS)

    Morgan, M.A.; Horstmeier, C.D.; DeYoung, D.R.; Roberts, G.D.

    1983-01-01

    The BACTEC system and three conventional media (Middlebrook 7H10, selective Middlebrook 7H11 [S7H11], and Lowenstein-Jensen [LJ] were compared for their mean recovery times and recovery rates of mycobacteria from acid-fast, smear-negative clinical specimens. Of the 71 smear-negative, culture-positive specimens recovered from 2,165 submitted smear-negative cultures, the BACTEC system detected 71.8%, compared with 88.7% for the conventional three-medium system. When media were individually compared, BACTEC medium (Middlebrook 7H12) was more successful in recovering mycobacteria (71.8%) than was LJ (62%), Middlebrook medium 7H10 (55.9%), or Middlebrook S7H11 medium (52.1%). Middlebrook 7H11 medium containing sodium selenate was also evaluated and did not increase the recovery rate or decrease the recovery time of mycobacterial species when compared with LJ, Middlebrook 7H10, S7H11, and 7H12 media. The mean detection time for the BACTEC system was less than that by conventional methods for the seven species of mycobacteria recovered. Detection times for Mycobacterium tuberculosis on the BACTEC system and conventional cultural systems were 13.7 and 26.3 days, respectively

  13. Improved detection of Mycobacterium avium complex with the Bactec radiometric system

    International Nuclear Information System (INIS)

    Hoffner, S.E.

    1988-01-01

    A reconsideration of the laboratory methods used for primary isolation of mycobacteria other than Mycobacterium tuberculosis is needed due to the increasingly recognized importance of such mycobacterial infections in immunocompromised patients. One example of this is the severe opportunistic infections caused by Mycobacterium avium complex among AIDS patients. In this study, the Bactec radiometric system was compared to conventional culture on solid medium for the detection of M. avium complex in 3,612 selected clinical specimens, mainly of extrapulmonary origin. Of a total number of 63 M. avium complex isolates, the Bactec system detected 58 (92%), compared to 37 (59%) for conventional culture. A much more rapid detection was attained with radiometric technique than with conventional culture. The mean detection time for the cultures positive with both methods was 7.1 and 28.3 days, respectively. The Bactec radiometric system achieves a rapid and significantly more sensitive detection and seems to be an excellent complement to conventional culture in the laboratory diagnosis of infections with the M. avium complex

  14. Radiometric detection of yeasts in blood cultures of cancer patients

    International Nuclear Information System (INIS)

    Hopfer, R.L.; Orengo, A.; Chesnut, S.; Wenglar, M.

    1980-01-01

    During a 12-month period, 19,457 blood cultures were collected. Yeasts were isolated from 193 cultures derived from 76 cancer patients. Candida albicans or Candida tropicalis accounted for 79% of isolates. Of the three methods compared, the radiometric method required 2.9 days to become positive, blind subculture required 2.6 days, and Gram stains required 1 day. However, the radiometric method was clearly superior in detecting positive cultures, since 73% of all cultures were first detected radiometrically, 22% were detected by subculture, and only 5% were detected by Gram stain. Although 93% of the isolates were detected by aerobic culture, five (7%) isolates were obtained only from anaerobic cultures. Seven days of incubation appear to be sufficient for the radiometric detection of yeasts

  15. A simple and rapid method to estimate radiocesium in man

    International Nuclear Information System (INIS)

    Kindl, P.; Steger, F.

    1990-09-01

    A simple and rapid method for monitoring internal contamination of radiocesium in man was developed. This method is based on measurements of the γ-rays emitted from the muscular parts between the thights by a simple NaJ(Tl)-system. The experimental procedure, the calibration, the estimation of the body activity and results are explained and discussed. (Authors)

  16. Radiometric report for a blast furnace tracing with radioactive isotopes

    International Nuclear Information System (INIS)

    Tanase, G.; Tanase, M.

    1995-01-01

    One of the methods to monitor refractory wall of blast furnace is its tracing with radioactive isotopes. The tracer isotope can be detected by two ways: the external dosimetric measurement at the armour of the blast furnace and/or the radiometric measurement of the iron sample charge by charge. Any change in radiometric situation of tracer radioisotope is recorded in a radiometric report. This paper presents an original concept of radiometric report based upon PARADOX and CORELDRAW soft kits. Their advantage are: quick and easy changes, easy recording of current radioactivity of tracer isotope, short history of changes, visual mapping of the tracer isotope and others. In this way we monitored 6 blast furnaces and more than 180 radioactive sources

  17. Methods for Rapid Screening in Woody Plant Herbicide Development

    Directory of Open Access Journals (Sweden)

    William Stanley

    2014-07-01

    Full Text Available Methods for woody plant herbicide screening were assayed with the goal of reducing resources and time required to conduct preliminary screenings for new products. Rapid screening methods tested included greenhouse seedling screening, germinal screening, and seed screening. Triclopyr and eight experimental herbicides from Dow AgroSciences (DAS 313, 402, 534, 548, 602, 729, 779, and 896 were tested on black locust, loblolly pine, red maple, sweetgum, and water oak. Screening results detected differences in herbicide and species in all experiments in much less time (days to weeks than traditional field screenings and consumed significantly less resources (<500 mg acid equivalent per herbicide per screening. Using regression analysis, various rapid screening methods were linked into a system capable of rapidly and inexpensively assessing herbicide efficacy and spectrum of activity. Implementation of such a system could streamline early-stage herbicide development leading to field trials, potentially freeing resources for use in development of beneficial new herbicide products.

  18. Modeling response variation for radiometric calorimeters

    International Nuclear Information System (INIS)

    Mayer, R.L. II.

    1986-01-01

    Radiometric calorimeters are widely used in the DOE complex for accountability measurements of plutonium and tritium. Proper characterization of response variation for these instruments is, therefore, vital for accurate assessment of measurement control as well as for propagation of error calculations. This is not difficult for instruments used to measure items within a narrow range of power values; however, when a single instrument is used to measure items over a wide range of power values, improper estimates of uncertainty can result since traditional error models for radiometric calorimeters assume that uncertainty is not a function of sample power. This paper describes methods which can be used to accurately estimate random response variation for calorimeters used to measure items over a wide range of sample powers. The model is applicable to the two most common modes of calorimeter operation: heater replacement and servo control. 5 refs., 4 figs., 1 tab

  19. Rapid spectrographic method for determining microcomponents in solutions

    International Nuclear Information System (INIS)

    Karpenko, L.I.; Fadeeva, L.A.; Gordeeva, A.N.; Ermakova, N.V.

    1984-01-01

    Rapid spectrographic method foe determining microcomponents (Cd, V, Mo, Ni, rare earths and other elements) in industrial and natural solutions has been developed. The analyses were conducted in argon medium and in the air. Calibration charts for determining individual rare earths in solutions are presented. The accuracy of analysis (Sr) was detection limit was 10 -3 -10 -4 mg/ml, that for rare earths - 1.10 -2 mg/ml. The developed method enables to rapidly analyze solutions (sewages and industrialllwaters, wine products) for 20 elements including 6 rare earths, using strandard equipment

  20. Sedimentation rates of Sao Paulo coast by carbonate calcium content: an alternative for radiometric methods; Levantamento das taxas de sedimentacao do litoral de Sao Paulo a partir do teor de carbonato de calcio: uma alternativa aos metodos radiometricos

    Energy Technology Data Exchange (ETDEWEB)

    Figueira, Rubens C.L. [Universidade Cruzeiro do Sul, Sao Paulo, SP (Brazil). Centro de Tecnologia e Ciencias Exatas]. E-mail: figueira@ipen.br; figueiraru@yahoo.com.br; Tessler, Moyses G.; Mahiques, Michel M. de; Fukumoto, Marina M.M. [Sao Paulo Univ., SP (Brazil). Inst. Oceanografico. Dept. de Oceanografia Geologica]. E-mail: mgtessle@usp.br; mahiques@usp.br; marina@io.usp.br

    2005-07-01

    In this work it is presented a methodology of sedimentation rate determination by carbonate calcium content. The technique developed is an alternative for radiometric methods where are used {sup 210}Pb{sub unsupported} and {sup 137}Cs radionuclides. This methodology consisted in a determination of chronologic event along sedimentary column. In this work two events were used: the tsunami in Sao Vicente city, in 1542, and the maximum of 1{sup 37}Cs radioactive fallout from nuclear atmospheric tests, in 1963-65. It was possible to calculate the accumulation rate of total sediments and precipitation rate of calcium carbonate, which values are necessary to determine the age of slice from sedimentary column and consequently the sedimentation rate. The results obtained for Sao Paulo Continental Shelf had a good agreement with radiometric methods, the values were: 0.32({+-}0.12) cm.y{sup -1}, 0.23({+-}0.08) cm.y{sup -1} and 0.25({+-}0.9) cm.y{sup -1} for carbonate method, {sup 210}Pb{sub unsupported} (CIC model) and {sup 137}Cs (radioactive fallout), respectively. The analytical procedure using carbonate calcium content showed to be fast, efficient and with low cost. However, it must be used carefully, because the results can be strongly influenced by environmental factors which could change the precipitation rate of calcium carbonate and it could cause errors on sedimentation rate values in a determined area (author)

  1. A Rapid Aeroelasticity Optimization Method Based on the Stiffness characteristics

    OpenAIRE

    Yuan, Zhe; Huo, Shihui; Ren, Jianting

    2018-01-01

    A rapid aeroelasticity optimization method based on the stiffness characteristics was proposed in the present study. Large time expense in static aeroelasticity analysis based on traditional time domain aeroelasticity method is solved. Elastic axis location and torsional stiffness are discussed firstly. Both torsional stiffness and the distance between stiffness center and aerodynamic center have a direct impact on divergent velocity. The divergent velocity can be adjusted by changing the cor...

  2. Radiometric surveys in underground environment

    Science.gov (United States)

    Bochiolo, Massimo; Chiozzi, Paolo; Verdoya, Massimo; Pasquale, Vincenzo

    2010-05-01

    Due to their ability to travel through the air for several metres, gamma-rays emitted from natural radioactive elements can be successfully used in surveys carried out both with airborne and ground equipments. Besides the concentration of the radio-elements contained in rocks and soils and the intrinsic characteristics of the gamma-ray detector, the detected count rate depends on the solid angle around the spectrometer. On a flat outcrop, ground spectrometry detects the radiation ideally produced by a cylindrical mass of rock of about two metres in diameter and thickness of about half a meter. Under these geometrical conditions, the natural radioactivity can be easily evaluated. With operating conditions different from the standard ones, such as at the edge of an escarpment, the count rate halves because of the missing material, whereas in the vicinity of a rock wall the count rate will increase. In underground environment, the recorded count rate may even double and the in situ assessment of the concentration of radio-elements may be rather difficult, even if the ratios between the different radio-elements may not be affected. We tested the applicability of gamma-ray spectrometry for rapid assessment of the potential hazard levels related to radon and radiation dose rate in underground environment. A mine shaft, located in a zone of uranium enrichment in Liguria (Italy), has been investigated. A preliminary ground radiometric survey was carried out to define the extent of the ore deposit. Then, the radiometric investigation was focussed on the mine shaft. Due to rock mass above the shaft vault, the background gamma radiation can be considered of negligible influence on measurements. In underground surveys, besides deviations from a flat geometry, factors controlling radon exhalation, emanation and stagnation, such as fractures, water leakage and the presence of ventilation, should be carefully examined. We attempted to evaluate these control factors and collected

  3. Optical Imaging and Radiometric Modeling and Simulation

    Science.gov (United States)

    Ha, Kong Q.; Fitzmaurice, Michael W.; Moiser, Gary E.; Howard, Joseph M.; Le, Chi M.

    2010-01-01

    OPTOOL software is a general-purpose optical systems analysis tool that was developed to offer a solution to problems associated with computational programs written for the James Webb Space Telescope optical system. It integrates existing routines into coherent processes, and provides a structure with reusable capabilities that allow additional processes to be quickly developed and integrated. It has an extensive graphical user interface, which makes the tool more intuitive and friendly. OPTOOL is implemented using MATLAB with a Fourier optics-based approach for point spread function (PSF) calculations. It features parametric and Monte Carlo simulation capabilities, and uses a direct integration calculation to permit high spatial sampling of the PSF. Exit pupil optical path difference (OPD) maps can be generated using combinations of Zernike polynomials or shaped power spectral densities. The graphical user interface allows rapid creation of arbitrary pupil geometries, and entry of all other modeling parameters to support basic imaging and radiometric analyses. OPTOOL provides the capability to generate wavefront-error (WFE) maps for arbitrary grid sizes. These maps are 2D arrays containing digital sampled versions of functions ranging from Zernike polynomials to combination of sinusoidal wave functions in 2D, to functions generated from a spatial frequency power spectral distribution (PSD). It also can generate optical transfer functions (OTFs), which are incorporated into the PSF calculation. The user can specify radiometrics for the target and sky background, and key performance parameters for the instrument s focal plane array (FPA). This radiometric and detector model setup is fairly extensive, and includes parameters such as zodiacal background, thermal emission noise, read noise, and dark current. The setup also includes target spectral energy distribution as a function of wavelength for polychromatic sources, detector pixel size, and the FPA s charge

  4. Rapid Enzymatic Method for Pectin Methyl Esters Determination

    Directory of Open Access Journals (Sweden)

    Lucyna Łękawska-Andrinopoulou

    2013-01-01

    Full Text Available Pectin is a natural polysaccharide used in food and pharma industries. Pectin degree of methylation is an important parameter having significant influence on pectin applications. A rapid, fully automated, kinetic flow method for determination of pectin methyl esters has been developed. The method is based on a lab-made analyzer using the reverse flow-injection/stopped flow principle. Methanol is released from pectin by pectin methylesterase in the first mixing coil. Enzyme working solution is injected further downstream and it is mixed with pectin/pectin methylesterase stream in the second mixing coil. Methanol is oxidized by alcohol oxidase releasing formaldehyde and hydrogen peroxide. This reaction is coupled to horse radish peroxidase catalyzed reaction, which gives the colored product 4-N-(p-benzoquinoneimine-antipyrine. Reaction rate is proportional to methanol concentration and it is followed using Ocean Optics USB 2000+ spectrophotometer. The analyzer is fully regulated by a lab written LabVIEW program. The detection limit was 1.47 mM with an analysis rate of 7 samples h−1. A paired t-test with results from manual method showed that the automated method results are equivalent to the manual method at the 95% confidence interval. The developed method is rapid and sustainable and it is the first application of flow analysis in pectin analysis.

  5. A rapid, simple method for obtaining radiochemically pure hepatic heme

    International Nuclear Information System (INIS)

    Bonkowski, H.L.; Bement, W.J.; Erny, R.

    1978-01-01

    Radioactively-labelled heme has usually been isolated from liver to which unlabelled carrier has been added by long, laborious techniques involving organic solvent extraction followed by crystallization. A simpler, rapid method is devised for obtaining radiochemically-pure heme synthesized in vivo in rat liver from delta-amino[4- 14 C]levulinate. This method, in which the heme is extracted into ethyl acetate/glacial acetic acid and in which porphyrins are removed from the heme-containing organic phase with HCl washes, does not require addition of carrier heme. The new method gives better heme recoveries than and heme specific activities identical to, those obtained using the crystallization method. In this new method heme must be synthesized from delta-amino[4- 14 C]levulinate; it is not satisfactory to use [2- 14 C]glycine substrate because non-heme counts are isolated in the heme fraction. (Auth.)

  6. Itinerant radiometric laboratory (IRL-76)

    International Nuclear Information System (INIS)

    Dolgirev, E.I.; Domaratskij, V.P.; Kostikov, Yu.I.

    1978-01-01

    A mobile radiometric laboratory for routine radiation monitoring of the environment, personnel, and population is described. As compared to the previous models, this one incorporates a number of new features and is more informative and versatile. The design and main technical and operating characteristics of the laboratory are detailed

  7. Rapid methods for jugular bleeding of dogs requiring one technician.

    Science.gov (United States)

    Frisk, C S; Richardson, M R

    1979-06-01

    Two methods were used to collect blood from the jugular vein of dogs. In both techniques, only one technician was required. A rope with a slip knot was placed around the base of the neck to assist in restraint and act as a tourniquet for the vein. The technician used one hand to restrain the dog by the muzzle and position the head. The other hand was used for collecting the sample. One of the methods could be accomplished with the dog in its cage. The bleeding techniques were rapid, requiring approximately 1 minute per dog.

  8. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues

    Science.gov (United States)

    Ji, Wei; Yao, Weirong

    2015-06-01

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm-1, 1344 cm-1, 1596 cm-1, which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm-1 was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R2 = 0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples.

  9. A novel method for rapid in vitro radiobioassay

    Science.gov (United States)

    Crawford, Evan Bogert

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are the detonation of a radiation dispersal device (RDD, "dirty bomb") or the accidental release of an isotope from an industrial source such as a radioisotopic thermal generator (RTG). In the event of the release and dispersion of radioactive materials into the environment in a large city, the entire population of the city -- including all commuting workers and tourists -- would have to be rapidly tested, both to satisfy the psychological needs of the citizens who were exposed to the mental trauma of a possible radiation dose, and to satisfy the immediate medical needs of those who received the highest doses and greatest levels of internal contamination -- those who would best benefit from rapid, intensive medical care. In this research a prototype rapid screening method to screen urine samples for the presence of up to five isotopes, both individually and in a mixture, has been developed. The isotopes used to develop this method are Co-60, Sr-90, Cs-137, Pu-238, and Am-241. This method avoids time-intensive chemical separations via the preparation and counting of a single sample on multiple detectors, and analyzing the spectra for isotope-specific markers. A rapid liquid-liquid separation using an organic extractive scintillator can be used to help quantify the activity of the alpha-emitting isotopes. The method provides quantifiable results in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their respective intervention levels in approximately 30

  10. Rapid assessment methods in eye care: An overview

    Directory of Open Access Journals (Sweden)

    Srinivas Marmamula

    2012-01-01

    Full Text Available Reliable information is required for the planning and management of eye care services. While classical research methods provide reliable estimates, they are prohibitively expensive and resource intensive. Rapid assessment (RA methods are indispensable tools in situations where data are needed quickly and where time- or cost-related factors prohibit the use of classical epidemiological surveys. These methods have been developed and field tested, and can be applied across almost the entire gamut of health care. The 1990s witnessed the emergence of RA methods in eye care for cataract, onchocerciasis, and trachoma and, more recently, the main causes of avoidable blindness and visual impairment. The important features of RA methods include the use of local resources, simplified sampling methodology, and a simple examination protocol/data collection method that can be performed by locally available personnel. The analysis is quick and easy to interpret. The entire process is inexpensive, so the survey may be repeated once every 5-10 years to assess the changing trends in disease burden. RA survey methods are typically linked with an intervention. This article provides an overview of the RA methods commonly used in eye care, and emphasizes the selection of appropriate methods based on the local need and context.

  11. Testing of X-ray radiometric enrichnment of polymetallic ores

    International Nuclear Information System (INIS)

    Eliseev, N.I.; Panova, N.I.; Kirbitova, N.V.; Shramm, E.O.; Efremov, Yu.G.

    1987-01-01

    Testing of X-ray radiometric method of sorting of polymetallic ores using the developed X-ray radiometric device was conducted. It was shown that introduction of preliminary concentration at the factory made the method of fragment separation to be the perspective one, enabling to elevate the factory production with respect to commercial ore and reduce the cost of ore processing. In the case of preliminary concentration, conducted at the mine, it is advisable to perform ore sorting in the flow formed to monolayer

  12. Method for producing rapid pH changes

    Science.gov (United States)

    Clark, J.H.; Campillo, A.J.; Shapiro, S.L.; Winn, K.R.

    A method of initiating a rapid pH change in a solution comprises irradiating the solution with an intense flux of electromagnetic radiation of a frequency which produces a substantial pK change to a compound in solution. To optimize the resulting pH change, the compound being irradiated in solution should have an excited state lifetime substantially longer than the time required to establish an excited state acid-base equilibrium in the solution. Desired pH changes can be accomplished in nanoseconds or less by means of picosecond pulses of laser radiation.

  13. Method for rapidly determining a pulp kappa number using spectrophotometry

    Science.gov (United States)

    Chai, Xin-Sheng; Zhu, Jun Yong

    2002-01-01

    A system and method for rapidly determining the pulp kappa number through direct measurement of the potassium permanganate concentration in a pulp-permanganate solution using spectrophotometry. Specifically, the present invention uses strong acidification to carry out the pulp-permanganate oxidation reaction in the pulp-permanganate solution to prevent the precipitation of manganese dioxide (MnO.sub.2). Consequently, spectral interference from the precipitated MnO.sub.2 is eliminated and the oxidation reaction becomes dominant. The spectral intensity of the oxidation reaction is then analyzed to determine the pulp kappa number.

  14. Radiometric measurement independent of profile. Belt weighers

    International Nuclear Information System (INIS)

    Otto, J.

    1986-01-01

    Radiometric measuring techniques allow contactless determination of the material carried by belt conveyors. Data defining the material is obtained via attenuation of gamma rays passing through the material on the belt. The method applies the absorption law according to Lambert-Beer, which has to be corrected by a build-up factor because of the stray radiation induced by the Compton effect. The profile-dependent error observed with conventional radiometric belt weighers is caused by the non-linearity of the absorption law in connection with the simultaneous summation of the various partial rays in a detector. The scanning method allows separate evaluation of the partial rays' attenuation and thus yields the correct data of the material carried, regardless of the profile. The scanning method is applied on a finite number of scanning sections, and a residual error has to be taken into account. The stochastics of quantum emission and absorption leads to an error whose expectation value is to be taken into account in the scanning algorithm. As the conveyor belt is in motion during the process of measurements, only part of the material conveyed is irradiated. The resulting assessment error is investigated as a function of the autocorrelation function of the material on the belt. (orig./HP) [de

  15. Radiometric densimeter for measuring and automatic control of liquid density

    International Nuclear Information System (INIS)

    Wajs, J.

    1982-01-01

    A performance rule of the radiometric densimeter produced by ''POLON ''Works is presented. A simplified analysis of the correction of density indication changes due to liquid temperature variations is described. A method of replacing the measuring pipe carrying the liquid being measured by suitable standards is given. The method is for automatic systems control. (A.S.)

  16. Radiometric dating and quantitative analysis of elements in depth profiles of sediments by means of nuclear physical as well as X-ray fluorescence and atomic emission spectroscopic methods

    International Nuclear Information System (INIS)

    Schoenburg, M.

    1987-01-01

    The measurement of heavy metal concentration in sediments is of great importance for the assessment of water quality. If dating of the different layers of sediment cores is possible, informations about the history of pollution can be inferred. This paper describes the development and practical test of a procedure suitable for the investigation of sediment cores. Both the element analysis and the dating are based on physical methods. For element concentration determination inductively coupled plasma atomic emission spectrometry (ICP), total-reflection X-ray fluorescence analysis (TXRF) and neutron activation analysis (NAA) are used. The techniques are described and compared. For dating radiometric measurements of 210 Pb and 137 Cs are carried out with a coaxial well-type germanium γ-ray detector in a special low-level arrangement. Results of the systematic investigations are presented and a few individual depth profiles are discussed. (orig.) With 34 figs., 20 tabs [de

  17. Radiometric measurement techniques in metallurgy and foundry technology

    International Nuclear Information System (INIS)

    1990-01-01

    The contributions contain informations concerning the present state and development of radiometric measurement techniques in metallurgy and foundry technology as well as their application to the solution of various problems. The development of isotope techniques is briefly described. Major applications of radiometric equipment in industrial measurement are presented together with the use of isotopes to monitor processes of industrial production. This is followed by a short description of numerous laboratory-scale applications. Another contribution deals with fundamental problems and methods of moisture measurement by neutrons. A complex moisture/density measurement device the practical applicability of which has been tested is described here. Possibilities for clay determination in used-up moulding materials are discussed in a further contribution. The clay content can be determined by real-time radiometric density measurement so that the necessary moisture or addition of fresh sand can be controlled. (orig.) With 20 figs., 9 tabs., 178 refs [de

  18. A method for rapid similarity analysis of RNA secondary structures

    Directory of Open Access Journals (Sweden)

    Liu Na

    2006-11-01

    Full Text Available Abstract Background Owing to the rapid expansion of RNA structure databases in recent years, efficient methods for structure comparison are in demand for function prediction and evolutionary analysis. Usually, the similarity of RNA secondary structures is evaluated based on tree models and dynamic programming algorithms. We present here a new method for the similarity analysis of RNA secondary structures. Results Three sets of real data have been used as input for the example applications. Set I includes the structures from 5S rRNAs. Set II includes the secondary structures from RNase P and RNase MRP. Set III includes the structures from 16S rRNAs. Reasonable phylogenetic trees are derived for these three sets of data by using our method. Moreover, our program runs faster as compared to some existing ones. Conclusion The famous Lempel-Ziv algorithm can efficiently extract the information on repeated patterns encoded in RNA secondary structures and makes our method an alternative to analyze the similarity of RNA secondary structures. This method will also be useful to researchers who are interested in evolutionary analysis.

  19. Developing rapid methods for analyzing upland riparian functions and values.

    Science.gov (United States)

    Hruby, Thomas

    2009-06-01

    Regulators protecting riparian areas need to understand the integrity, health, beneficial uses, functions, and values of this resource. Up to now most methods providing information about riparian areas are based on analyzing condition or integrity. These methods, however, provide little information about functions and values. Different methods are needed that specifically address this aspect of riparian areas. In addition to information on functions and values, regulators have very specific needs that include: an analysis at the site scale, low cost, usability, and inclusion of policy interpretations. To meet these needs a rapid method has been developed that uses a multi-criteria decision matrix to categorize riparian areas in Washington State, USA. Indicators are used to identify the potential of the site to provide a function, the potential of the landscape to support the function, and the value the function provides to society. To meet legal needs fixed boundaries for assessment units are established based on geomorphology, the distance from "Ordinary High Water Mark" and different categories of land uses. Assessment units are first classified based on ecoregions, geomorphic characteristics, and land uses. This simplifies the data that need to be collected at a site, but it requires developing and calibrating a separate model for each "class." The approach to developing methods is adaptable to other locations as its basic structure is not dependent on local conditions.

  20. Microsomal aryl hydrocarbon hydroxylase comparison of the direct, indirect and radiometric assays

    International Nuclear Information System (INIS)

    Denison, M.S.; Murray, M.; Wilkinson, C.F.

    1983-01-01

    The direct fluorometric assay of aryl hydrocarbon hydroxlyase has been compared to the more commonly used indirect fluorometric and radiometric assays. Although rat hepatic microsomal activities measured by the direct assay were consistently higher than those obtained by the other assays, the relative changes in activity following enzyme induction and/or inhibition were similar. The direct assay provides an accurate and rapid measure of aryl hydrocarbon hydroxylase activity and avoids several problems inherent in the indirect and radiometric assays. 2 tables

  1. A Rapid Method for the Determination of Fucoxanthin in Diatom

    Directory of Open Access Journals (Sweden)

    Li-Juan Wang

    2018-01-01

    Full Text Available Fucoxanthin is a natural pigment found in microalgae, especially diatoms and Chrysophyta. Recently, it has been shown to have anti-inflammatory, anti-tumor, and anti-obesityactivity in humans. Phaeodactylum tricornutum is a diatom with high economic potential due to its high content of fucoxanthin and eicosapentaenoic acid. In order to improve fucoxanthin production, physical and chemical mutagenesis could be applied to generate mutants. An accurate and rapid method to assess the fucoxanthin content is a prerequisite for a high-throughput screen of mutants. In this work, the content of fucoxanthin in P. tricornutum was determined using spectrophotometry instead of high performance liquid chromatography (HPLC. This spectrophotometric method is easier and faster than liquid chromatography and the standard error was less than 5% when compared to the HPLC results. Also, this method can be applied to other diatoms, with standard errors of 3–14.6%. It provides a high throughput screening method for microalgae strains producing fucoxanthin.

  2. A rapid method for titration of ascovirus infectivity.

    Science.gov (United States)

    Han, Ningning; Chen, Zishu; Wan, Hu; Huang, Guohua; Li, Jianhong; Jin, Byung Rae

    2018-05-01

    Ascoviruses are a recently described family and the traditional plaque assay and end-point PCR assay have been used for their titration. However, these two methods are time-consuming and inaccurate to titrate ascoviruses. In the present study, a quick method for the determination of the titer of ascovirus stocks was developed based on ascovirus-induced apoptosis in infected insect cells. Briefly, cells infected with serial dilutions of virus (10 -2 -10 -10 ) for 24 h were stained with trypan blue. The stained cells were counted, and the percentage of nonviable cells was calculated. The stained cell rate was compared between virus-infected and control cells. The minimum-dilution group that had a significant difference compared with control and the maximum-dilution group that had no significant difference were selected and then compared each well of the two groups with the average stained cell rate of control. The well was marked as positive well if the stained cell rate was higher than the average stained cell rate of control wells; otherwise, the well was marked as negative wells. The percentage of positive wells were calculated according to the number of positive. Subsequently, the virus titer was calculated through the method of Reed and Muench. This novel method is rapid, simple, reproducible, accurate, and less material-consuming and eliminates the subjectivity of the other procedures for titrating ascoviruses. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. A simple method for rapidly processing HEU from weapons returns

    Energy Technology Data Exchange (ETDEWEB)

    McLean, W. II; Miller, P.E.

    1994-01-01

    A method based on the use of a high temperature fluidized bed for rapidly oxidizing, homogenizing and down-blending Highly Enriched Uranium (HEU) from dismantled nuclear weapons is presented. This technology directly addresses many of the most important issues that inhibit progress in international commerce in HEU; viz., transaction verification, materials accountability, transportation and environmental safety. The equipment used to carry out the oxidation and blending is simple, inexpensive and highly portable. Mobile facilities to be used for point-of-sale blending and analysis of the product material are presented along with a phased implementation plan that addresses the conversion of HEU derived from domestic weapons and related waste streams as well as material from possible foreign sources such as South Africa or the former Soviet Union.

  4. Compact radiometric microwave calibrator

    International Nuclear Information System (INIS)

    Fixsen, D. J.; Wollack, E. J.; Kogut, A.; Limon, M.; Mirel, P.; Singal, J.; Fixsen, S. M.

    2006-01-01

    The calibration methods for the ARCADE II instrument are described and the accuracy estimated. The Steelcast coated aluminum cones which comprise the calibrator have a low reflection while maintaining 94% of the absorber volume within 5 mK of the base temperature (modeled). The calibrator demonstrates an absorber with the active part less than one wavelength thick and only marginally larger than the mouth of the largest horn and yet black (less than -40 dB or 0.01% reflection) over five octaves in frequency

  5. Radiometric temperature measurements fundamentals

    CERN Document Server

    Zhang, Zhuomin M; Machin, Graham

    2009-01-01

    This book describes the theory of radiation thermometry, both at a primary level and for a variety of applications, such as in the materials processing industries and remote sensing. This book is written for those who will apply radiation thermometry in industrial practice; use radiation thermometers for scientific research; the radiation thermometry specialist in a national measurement institute; developers of radiation thermometers who are working to innovate products for instrument manufacturers, and developers of non-contact thermometry methods to address challenging thermometry problems.

  6. A rapid protection switching method in carrier ethernet ring networks

    Science.gov (United States)

    Yuan, Liang; Ji, Meng

    2008-11-01

    Abstract: Ethernet is the most important Local Area Network (LAN) technology since more than 90% data traffic in access layer is carried on Ethernet. From 10M to 10G, the improving Ethernet technology can be not only used in LAN, but also a good choice for MAN even WAN. MAN are always constructed in ring topology because the ring network could provide resilient path protection by using less resource (fibre or cable) than other network topologies. In layer 2 data networks, spanning tree protocol (STP) is always used to protect transmit link and preventing the formation of logic loop in networks. However, STP cannot guarantee the efficiency of service convergence when link fault happened. In fact, convergent time of networks with STP is about several minutes. Though Rapid Spanning Tree Protocol (RSTP) and Multi-Spanning Tree Protocol (MSTP) improve the STP technology, they still need a couple of seconds to achieve convergence, and can not provide sub-50ms protection switching. This paper presents a novel rapid ring protection method (RRPM) for carrier Ethernet. Unlike other link-fault detection method, it adopts distributed algorithm to detect link fault rapidly (sub-50ms). When networks restore from link fault, it can revert to the original working state. RRPM can provide single ring protection and interconnected ring protection without the formation of super loop. In normal operation, the master node blocks the secondary port for all non-RRPM Ethernet frames belonging to the given RRPM Ring, thereby avoiding a loop in the ring. When link fault happens, the node on which the failure happens moves from the "ring normal" state to the "ring fault" state. It also sends "link down" frame immediately to other nodes and blocks broken port and flushes its forwarding database. Those who receive "link down" frame will flush forwarding database and master node should unblock its secondary port. When the failure restores, the whole ring will revert to the normal state. That is

  7. Radiometric weighing devices. Part 1 and 2

    International Nuclear Information System (INIS)

    Glaeser, M.

    1985-01-01

    Proceeding from the physical and mathematical fundamentals and from the types of radiometric weighing devices presently available, the radiation protection problems arising from the application of radiometric gages in industry and agriculture are discussed. Nuclear weighing devices have been found to be effective from economic point of view but in some cases gravimetric conveyor weighers are indispensable. Information and guidance is given especially for users of radiometric weighing devices. 91 refs., 69 figs., and 8 tabs

  8. Map of natural gamma radiation in Spain: radiometric characterization of different types of surfaces

    International Nuclear Information System (INIS)

    Suarez Mahou, E.; Fernandez Amigot, J.A.; Botas Medina, J.

    1997-01-01

    The gamma radioactivity flowing from ground and rocks is due to the presence in these of uranium, thorium and potassium-40. The method of radiometric characterization depends on the purpose of the undertaking. Radiometric characterization can be realized on big surfaces (tens or hundreds of square kilometres studied on a national scale), medium size surfaces (50 to 1000 square kilometres, for example, in epidemiological or biological studies in areas with a determined radiometric background) small surfaces of less than 50 square kilometres (industrial sites, pre-operational studies, etc.). This article considers aspects of radiometric characterization on surfaces of interest and describes the contribution of the MARNA (Natural Provisional Radiation Map of Spain) Project selection and radiometric characterization

  9. Rapid method for Detection of Irradiation Mango Fruits

    International Nuclear Information System (INIS)

    El Salhy, F.T.

    2011-01-01

    To detect mango fruits which have been exposed to low doses of gamma rays (0.5-3.0 kGy), three recommended methods by European Committee for Standardization (EN 1784:1996, EN 1785:1996 and EN 1787:2000) were used to study the possibility for identification of irradiated mango fruits (Ewais variety). Fresh mangoes were irradiated to different doses (0.5, 0.75, 1.0 and 3.0 kGy). The first method for determining the volatile hydrocarbons (VHC) was carried out by using florisil column then identified by gas chromatography and mass spectrometry (GC-MS). The major VHCs were C14:1, C15:0 and C17:1 at different doses which increased linearly with increasing doses either at low or high doses. The second one for determining the 2-alkyl cyclobutanone (2-DCB) was carried out using florisil chromatography method activated with 20% for separation and identified by GC-MS. 2-DCB bio marker specific for irradiated food proved its presence at the applied doses from 0.75-3.0 kGy but not at 0.5 kGy. All the mentioned compounds could not detected in non-irradiated samples, which mean that these radiolytic products (VHC and 2-DCB) can be used as a detection markers for irradiated mangoes even at low doses. The third one (EN 1787:2000) was conducted by electron spin resonance (ESR) on dried petioles of mangoes. The results proved that ESR was more sensitive for all applied doses.It could be concluded that using the three methods can be succeeded for detection of irradiated mangoes but the rapid one even at low doses with high accuracy was ESR.

  10. Electrochemical method for rapid synthesis of Zinc Pentacyanonitrosylferrate Nanotubes

    Directory of Open Access Journals (Sweden)

    Rogaieh Bargeshadi

    2014-10-01

    Full Text Available In this paper, a rapid and simple approach was developed for the preparation of zinc pentacyanonitrosylferrate nanotubes (ZnPCNF NTs within the cylindrical pores of anodic aluminum oxide (AAO template by electrochemical method. The AAO was fabricated in two steps anodizing from aluminum foil. The first anodization of aluminum foil was performed in 0.2 mol L-1 H2C2O4 followed by removal of the formed porous oxide film by a solution of 6 wt% of phosphoric acid. The second anodization step was then performed using the same conditions as the previous step. Scanning electron microscope (SEM and X-ray diffraction (XRD method were employed to characterize the resulting highly oriented uniform hollow tube array which its diameter was in the range of 25-75 nm depending on the applied voltage and the length of nanotubes was equal to the thickness of AAO which was about 2 m. The growth properties of the ZnPCNF NTs array film can be achieved by controlling the structure of the template and applied potential across the cell.

  11. Rapid and robust detection methods for poison and microbial contamination.

    Science.gov (United States)

    Hoehl, Melanie M; Lu, Peter J; Sims, Peter A; Slocum, Alexander H

    2012-06-27

    Real-time on-site monitoring of analytes is currently in high demand for food contamination, water, medicines, and ingestible household products that were never tested appropriately. Here we introduce chemical methods for the rapid quantification of a wide range of chemical and microbial contaminations using a simple instrument. Within the testing procedure, we used a multichannel, multisample, UV-vis spectrophotometer/fluorometer that employs two frequencies of light simultaneously to interrogate the sample. We present new enzyme- and dye-based methods to detect (di)ethylene glycol in consumables above 0.1 wt % without interference and alcohols above 1 ppb. Using DNA intercalating dyes, we can detect a range of pathogens ( E. coli , Salmonella , V. Cholera, and a model for Malaria) in water, foods, and blood without background signal. We achieved universal scaling independent of pathogen size above 10(4) CFU/mL by taking advantage of the simultaneous measurement at multiple wavelengths. We can detect contaminants directly, without separation, purification, concentration, or incubation. Our chemistry is stable to ± 1% for >3 weeks without refrigeration, and measurements require <5 min.

  12. Radiometric calipers for borehole logging

    International Nuclear Information System (INIS)

    Charbucinski, J.; Wylie, A.W.; Jarrett, R.G.

    1976-01-01

    Two versions of a radiometric-type caliper for measuring borehole diameter are described. One, based on the bow-spring principle, is suitable for percussion (exploration) drill holes. The other, which utilizes hemispherical wall contactors actuated by springs, is suitable for blast holes. Both utilize low-power radioactive sources and employ a scintillation detector to measure the 'inverse-square law' response of the device to changes in borehole radius. The performance of the device is examined and examples of its use are illustrated. (author)

  13. Rapid simulation of spatial epidemics: a spectral method.

    Science.gov (United States)

    Brand, Samuel P C; Tildesley, Michael J; Keeling, Matthew J

    2015-04-07

    Spatial structure and hence the spatial position of host populations plays a vital role in the spread of infection. In the majority of situations, it is only possible to predict the spatial spread of infection using simulation models, which can be computationally demanding especially for large population sizes. Here we develop an approximation method that vastly reduces this computational burden. We assume that the transmission rates between individuals or sub-populations are determined by a spatial transmission kernel. This kernel is assumed to be isotropic, such that the transmission rate is simply a function of the distance between susceptible and infectious individuals; as such this provides the ideal mechanism for modelling localised transmission in a spatial environment. We show that the spatial force of infection acting on all susceptibles can be represented as a spatial convolution between the transmission kernel and a spatially extended 'image' of the infection state. This representation allows the rapid calculation of stochastic rates of infection using fast-Fourier transform (FFT) routines, which greatly improves the computational efficiency of spatial simulations. We demonstrate the efficiency and accuracy of this fast spectral rate recalculation (FSR) method with two examples: an idealised scenario simulating an SIR-type epidemic outbreak amongst N habitats distributed across a two-dimensional plane; the spread of infection between US cattle farms, illustrating that the FSR method makes continental-scale outbreak forecasting feasible with desktop processing power. The latter model demonstrates which areas of the US are at consistently high risk for cattle-infections, although predictions of epidemic size are highly dependent on assumptions about the tail of the transmission kernel. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Study on tube rupture strength evaluation method for rapid overheating

    International Nuclear Information System (INIS)

    Komine, Ryuji; Wada, Yusaku

    1998-08-01

    A sodium-water reaction derived from the single tube break in steam generator might overheat neighbor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. In the present study this phenomenon was recognized as the fracture of cylindrical tube with the large deformation due to overheating, and the evaluation method was investigated based on both of experimental and analytical approaches. The results obtained are as follows. (1) As for the nominal stress estimation, it was clarified through the experimental data and the detailed FEM elasto-plastic large deformation analysis that the formula used in conventional designs can be applied. (2) Within the overheating temperature limits of tubes, the creep effect is dominant, even if the loading time is too short. So the strain rate on the basis of JIS elevated temperature tensile test method for steels and heat-resisting alloys is too late and almost of total strain is composed by creep one. As a result the time dependent effect cannot be evaluated under JIS strain rate condition. (3) Creep tests in shorter time condition than a few minutes and tensile tests in higher strain rate condition than 10%/min of JIS are carried out for 2 1/4Cr-1Mo(NT) steel, and the standard values for tube rupture strength evaluation are formulated. (4) The above evaluation method based on both of the stress estimation and the strength standard values application is justified by using the tube burst test data under internal pressure. (5) The strength standard values on Type 321 ss is formulated in accordance with the procedure applied for 2 1/4Cr-1Mo(NT) steel. (author)

  15. Rapid preparation method for technetium-99m bicisate

    Energy Technology Data Exchange (ETDEWEB)

    Hung, J.C. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Chowdhury, S. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Redfern, M.G. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Mahoney, D.W. [Section of Biostatistics, Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota (United States)

    1997-06-10

    The method currently recommended for the preparation of technetium-99m bicisate ({sup 99m}Tc-bicisate) requires a lengthy 30-min incubation at room temperature. The purpose of this study was to evaluate an alternative method to shorten the preparation time. {sup 99m}Tc-bicisate was prepared with 3.7 GBq (100 mCi) {sup 99m}Tc according to the manufacturer`s instructions, except for the final incubation step, which was replaced with the microwave heating procedure. A standard thin-layer chromatography (TLC) method (i.e., Baker-Flex silica gel IB-F TLC plate with ethyl acetate as mobile phase) was used for the determination of the radiochemical purity (RCP) of {sup 99m}Tc-bicisate. Our evaluation with different microwave heating processes (300 W with different heating times) demonstrated that as the microwave heating temperature was increased (i.e., 44 -71 C), an increased percentage of samples reached 95% within 5 min post preparation (n=58). The highest RCP value (i.e., 97.4%{+-}0.5%, n=10) could be obtained immediately after an 8-s microwave heating time at 300 W (microwave temperature at 69 C), and an average RCP value of 96.4%{+-}1.3% (n=90) was maintained throughout the 24-h evaluation period. However, the trend seemed to reverse at higher microwave temperatures (i.e., 76 -90 C), which reconfirmed our initial findings that overheating had no benefit for the preparation of {sup 99m}Tc-bicisate. To ensure that temperature was the only determining factor, a hot water incubator set at 69 C was used (n=6). Similar RCP results were achieved. In conclusion, the use of a microwave oven at a low heat cycle provides a rapid and efficient way to prepare {sup 99m}Tc-bicisate. (orig.). With 3 figs., 1 tab.

  16. Rapid Methods for the Laboratory Identification of Pathogenic Microorganisms.

    Science.gov (United States)

    1982-09-01

    coli Hemophilus influenzae Bacillus anthracis Bacillus circulans Bacillus coagulans Bacillus cereus T Candida albicans Cryptococcus neoformans Legionel...reveree aide If neceeeary and Identify by block number) Lectins: Rapid Identification, Bacillus anthracisjCryptococcus " neoformans. Neisseria...field-type kit for the rapid identification of Bacillus anthracis. We have shown that certain lectins will selectively interact with B. anthracis

  17. Monitoring of radioiodine and methods for rapid measurement, 2

    International Nuclear Information System (INIS)

    Kamada, Hiroshi

    1979-01-01

    Milk is selected as an indicator or critical food in the environmental monitoring samples, and radioactive iodine as a specific critical radionuclide. Rapid determination of Iodine-131 in the milk has been developed as a standard procedure for the network of environmental radioactivity monitoring in a state of emergency. Outline of the procedure is gamma-ray spectrometry using a heavily shielded 3''diameter x 3'' sodium iodide (thallium-activated) crystal as a detector, 2 liter of Marinelli Beaker for a raw milk and a multi channel pulse height analyzer for quantitative analysis of gamma spectra through the utilization of simultaneous equations. The analysis is what we call ''Milk Matrix Method'' introducing calibration data from the standard samples of Iodine-131, Cesium-137 and Potassium-40. They were selected experimentally, and counting data from the sample were taken into the elements of matrix of set up three simultaneous equations. Most recently detected concentration of Iodine-131 in milk was 81 pCi per liter in 20 May 1978, originated from the nuclear explosion test carried out by the People's Republic of China in 15 May 1978. (author)

  18. A rapid method of evaluating fluoroscopic system performance

    International Nuclear Information System (INIS)

    Sprawls, P.

    1989-01-01

    This paper presents a study to develop a method for the rapid evaluation and documentation of fluoroscopic image quality. All objects contained within a conventional contrast-detail test phantom (Leeds TO-10) are displayed in an array format according to their contrast and size. A copy of the display is used as the data collection form and a permanent record of system performance. A fluoroscope is evaluated by viewing the test phantom and marking the visible objects on the display. A line drawn through the objects with minimum visibility in each size group forms a contrast-detail curve for the system. This is compared with a standard or reference line, which is in the display.Deviations in curve position are useful indicators of specific image quality problems, such as excessive noise or blurring. The use of a special object-visibility array format display makes it possible to collect data, analyze the results, and create a record of fluoroscopic performance in less than 2 minutes for each viewing mode

  19. Rapid screening method for plutonium in mixed waste samples

    International Nuclear Information System (INIS)

    Somers, W.; Culp, T.; Miller, R.

    1987-01-01

    A waste stream sampling program was undertaken to determine those waste streams which contained hazardous constituents, and would therefore be regulated as a hazardous waste under the Resource Conservation and Recovery Act. The waste streams also had the potential of containing radioactive material, either plutonium, americium, or depleted uranium. Because of the potential for contamination with radioactive material, a method of rapidly screening the liquid samples for radioactive material was required. A counting technique was devised to count a small aliquot of a sample, determine plutonium concentration, and allow the sample to be shipped the same day they were collected. This technique utilized the low energy photons (x-rays) that accompany α decay. This direct, non-destructive x-ray analysis was applied to quantitatively determine Pu-239 concentrations in industrial samples. Samples contained a Pu-239, Am-241 mixture; the ratio and/or concentrations of these two radionuclides was not constant. A computer program was designed and implemented to calculate Pu-239 activity and concentration (g/ml) using the 59.5 keV Am-241 peak to determine Am-241's contribution to the 17 keV region. Am's contribution was subtracted, yielding net counts in the 17 keV region due to Pu. 2 figs., 1 tab

  20. Assessment of the effectiveness of uranium deposit searching methods

    International Nuclear Information System (INIS)

    Suran, J.

    1998-01-01

    The following groups of uranium deposit searching methods are described: radiometric review of foreign work; aerial radiometric survey; automobile radiometric survey; emanation survey up to 1 m; emanation survey up to 2 m; ground radiometric survey; radiometric survey in pits; deep radiometric survey; combination of the above methods; and other methods (drilling survey). For vein-type deposits, the majority of Czech deposits were discovered in 1945-1965 by radiometric review of foreign work, automobile radiometric survey, and emanation survey up to 1 m. The first significant indications of sandstone type uranium deposits were observed in the mid-1960 by aerial radiometric survey and confirmed later by drilling. (P.A.)

  1. The carrying out of a radiometric analysis method applicable to Moroccan phosphates. Study of the uranium amounts, of the U/Ra equilibrium ratio and of 222-radon emanation rates

    International Nuclear Information System (INIS)

    Choukri, A.

    1987-01-01

    A radiometric analysis method for the determination of the uranium and the radium amounts in Moroccan phosphate has been carried out, using NaI(Tl) scintillator to detect gamma radiation of 238-U and 235-U radioactive daughters. The analysis results permit to calculate the U/Ra equilibrium ratio and the emanation rates of 222-Rn versus temperature. The U/Ra disequilibria permit to detect the secondary contribution of a recent uranium. The 222-Rn emanation rates are useful in the evaluation of the radiological hazards related to the phosphate radioactivity. This method was applied to study the phosphate Ganntour deposit and showed that the uranium content ranges from 25ppm to 350ppm, that the U/Ra ratio ranges from 0.6 to 2.2 with an exceptional value of 4.5. The emanation rate of natural radon is between 0% and 27%. The radon forced emanation by heating or by adding different acids has also been studied. The phosphate attack with H 2 SO 4 and HNO 3 , using the analysis method, showed that a maximum degassing appears at 0.9cc/g for H 2 SO 4 and 1.1cc/g for HNO 3 . By adding H 2 SO 4 , 30% of uranium (without radium) passed in the solution and by adding HNO 3 uranium and radium are divided among the solid and the liquid phases. 22 refs., 49 figs., 25 tabs. (author)

  2. Radiometric Calibration of Osmi Imagery Using Solar Calibration

    Directory of Open Access Journals (Sweden)

    Dong-Han Lee

    2000-12-01

    Full Text Available OSMI (Ocean Scanning Multi-Spectral Imager raw image data (Level 0 were acquired and radiometrically corrected. We have applied two methods, using solar & dark calibration data from OSMI sensor and comparing with the SeaWiFS data, to the radiometric correction of OSMI raw image data. First, we could get the values of the gain and the offset for each pixel and each band from comparing the solar & dark calibration data with the solar input radiance values, calculated from the transmittance, BRDF (Bidirectional Reflectance Distribution Function and the solar incidence angle (¥â,¥è of OSMI sensor. Applying this calibration data to OSMI raw image data, we got the two odd results, the lower value of the radiometric corrected image data than the expected value, and the Venetian Blind Effect in the radiometric corrected image data. Second, we could get the reasonable results from comparing OSMI raw image data with the SeaWiFS data, and get a new problem of OSMI sensor.

  3. Development of rapid urine analysis method for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, J.; Noguchi, H. [Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-05-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  4. Development of rapid urine analysis method for uranium

    International Nuclear Information System (INIS)

    Kuwabara, J.; Noguchi, H.

    2000-01-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  5. Benchmarking electrical methods for rapid estimation of root biomass.

    Science.gov (United States)

    Postic, François; Doussan, Claude

    2016-01-01

    To face climate change and subsequent rainfall instabilities, crop breeding strategies now include root traits phenotyping. Rapid estimation of root traits in controlled conditions can be achieved by using parallel electrical capacitance and its linear correlation with root dry mass. The aim of the present study was to improve robustness and efficiency of methods based on capacitance and other electrical variables, such as serial/parallel resistance, conductance, impedance or reactance. Using different electrode configurations and stem contact electrodes, we have measured the electrical impedance spectra of wheat plants grown in pots filled with three types of soil. For each configuration, parallel capacitance and other linearly independent electrical variables were computed and their quality as root dry mass estimator was evaluated by a 'sensitivity score' that we derived from Pearson's correlation coefficient r and linear regression parameters. The highest sensitivity score was obtained by parallel capacitance at an alternating current frequency of 116 Hz in three-terminal configuration. Using a clamp, instead of a needle, as a stem electrode did not significantly affect the capacitance measurements. Finally, in handheld LCR meter equivalent conditions, capacitance had the highest sensitivity score and determination coefficient (r (2) = 0.52) at 10 kHz frequency. Our benchmarking of linear correlations between different electrical variables and root dry mass enables to determine more coherent practices for ensuring a sensitive and robust root dry mass estimation, including in handheld LCR meter conditions. This would enhance the value of electrical capacitance as a tool for screening crops in relation with root systems in breeding programs.

  6. Report on the feasibility of the in situ radiometric determination of uranium grade in Witwatersrand gold and uranium mines

    International Nuclear Information System (INIS)

    Smit, C.J.B.; Wesolinski, E.S.; Corner, B.

    1982-08-01

    The chip-sampling technique currently employed by the South African gold and uranium-mining industry, for the prediction of face grade, has several drawbacks, namely: 1) it is labour-intensive; 2) sample volumes are often unrepresentative and prone to human error; and 3) the uranium mineralisation may be very erratic along the reef. In situ radiometric assaying for uranium along the reef, on the other hand, is a rapid, essentially one-man operation, enabling a much larger and hence a more representative sample volume to be measured. The high radiometric background inherent in any uranium mine necessitates some form of high-density shielding in order to facilitate quantitative in situ assaying. This report, therefore, briefly outlines the origin, nature, detection and shielding of gamma rays. Results obtained with a frontally shielded total-count instrument showed that radiometric estimates of uranium grade are comparable to those obtained by batch mining and can be used for the prediction of face grades, provided that the ore is in radiometric equilibrium and that thorium and potassium are either not present, or vary sympathetically with the uranium grade. Spectral analysis showed, however, that these circumstances will also permit the use of a collimated (side-shielded) detector of acceptable weight, provided that only the low-energy portion of the spectrum is measured. The advantages of a collimated detector over a frontally shielded detector are also noteworthy, viz.: 1) only one reading is taken per sample point rather than two, as is the case with the frontally shielded system, thus improving counting statistics; and 2) the shielding is permanently fixed to the detector. Comprehensive design considerations for a compact, portable instrument are suggested and methods for determining background radiation as applicable to a collimated detector are described

  7. A new rapid method for rockfall energies and distances estimation

    Science.gov (United States)

    Giacomini, Anna; Ferrari, Federica; Thoeni, Klaus; Lambert, Cedric

    2016-04-01

    and distances at the base to block and slope features. The validation of the proposed approach was conducted by comparing predictions to experimental data collected in the field and gathered from the scientific literature. The method can be used for both natural and constructed slopes and easily extended to more complicated and articulated slope geometries. The study shows its great potential for a quick qualitative hazard assessment providing indication about impact energy and horizontal distance of the first impact at the base of a rock cliff. Nevertheless, its application cannot substitute a more detailed quantitative analysis required for site-specific design of mitigation measures. Acknowledgements The authors gratefully acknowledge the financial support of the Australian Coal Association Research Program (ACARP). References Dorren, L.K.A. (2003) A review of rockfall mechanics and modelling approaches, Progress in Physical Geography 27(1), 69-87. Agliardi, F., Crosta, G.B., Frattini, P. (2009) Integrating rockfall risk assessment and countermeasure design by 3D modelling techniques. Natural Hazards and Earth System Sciences 9(4), 1059-1073. Ferrari, F., Thoeni, K., Giacomini, A., Lambert, C. (2016) A rapid approach to estimate the rockfall energies and distances at the base of rock cliffs. Georisk, DOI: 10.1080/17499518.2016.1139729.

  8. Gamma radiometric survey of Jamaica

    International Nuclear Information System (INIS)

    Lalor, G.C.; Robotham, H.; Miller, J.M.; Simpson, P.R.

    1989-01-01

    The results of a total gamma radiometric survey of Jamaica, carried out with car-borne instrumentation, are presented and the data compared with the contents of potassium, thorium and uranium in rocks and in surface (soil, stream-sediment, pan concentrate and water) samples obtained at six sites selected to be representative of the principal rock types and surface environments of Jamaica. The work formed part of an orientation study for a regional geochemical survey of the CARICOM countries of the Caribbean. The initial results indicate that enhanced gamma activity is correlated with enrichment in uranium and thorium, but not potassium, in terra rossa soils and/or bauxite deposits in limestone. Elsewhere, gamma levels are increased on the Above Rocks Cretaceous basement Inlier, where they correlate generally with the presence of volcanogenic sediments and a granodiorite intrusion. The lowest radioactivity was recorded in the vicinity of ultrabasic rocks in the Blue Mountains Inlier. (author)

  9. The use of radiometric ore sorting on South African gold mines

    International Nuclear Information System (INIS)

    Boehme, R.C.; Freer, J.S.

    1982-01-01

    This paper refers to the radiometric sorting tests reported during the 7th CMMI Congress, and then describes the photometric and radiometric sorter installations in operation and under construction in South Africa at present. As radiometric sorting of gold ores uses the radiation from the uranium content as a tracer, it is essential that the sortability of the ore should be reliably determined before sorting is adopted. The method of obtaining the important ore characteristics is described, with examples. The possible increase in gold production from a hypothetical plant as a result of sorting is shown

  10. Choosing of mode and calculation of multiple regression equation parameters in X-ray radiometric analysis

    International Nuclear Information System (INIS)

    Mamikonyan, S.V.; Berezkin, V.V.; Lyubimova, S.V.; Svetajlo, Yu.N.; Shchekin, K.I.

    1978-01-01

    A method to derive multiple regression equations for X-ray radiometric analysis is described. Te method is realized in the form of the REGRA program in an algorithmic language. The subprograms included in the program are describe. In analyzing cement for Mg, Al, Si, Ca and Fe contents as an example, the obtainment of working equations in the course of calculations by the program is shown to simpliy the realization of computing devices in instruments for X-ray radiometric analysis

  11. Determination of reliability of express forecasting evaluation of radiometric enriching ability of non-ferrous ores

    International Nuclear Information System (INIS)

    Kirpishchikov, S.P.

    1991-01-01

    Use of the data of nuclear physical methods of sampling and logging enables to improve reliability of evaluation of radiometric enriching ability of ores, as well as to evaluate quantitatively this reliability. This problem may be solved by using some concepts of geostatistics. The presented results enable to conclude, that the data of nuclear-physical methods of sampling and logging can provide high reliability of evaluation of radiometric enriching ability of non-ferrous ores and their geometrization by technological types

  12. Detection and recovery of mycobacteria by a radiometric procedure

    International Nuclear Information System (INIS)

    Takahashi, H.; Foster, V.

    1983-01-01

    During a 6-month period, 5,375 clinical specimens were cultured on Middlebrook-Cohn 7H10 medium, on Lowenstein-Jensen medium, and in Middlebrook 7H12 medium containing [ 14 C]palmitic acid. More mycobacteria were recovered when all three media were used than when either the conventional method with 7H10 agar and Lowenstein-Jensen slants or the radiometric method with 7H12 broth was used alone

  13. Rapid method for identification of transgenic fish zygosity

    Directory of Open Access Journals (Sweden)

    . Alimuddin

    2007-07-01

    Full Text Available Identification of zygosity in transgenik fish is normally achieved by PCR analysis with genomic DNA template extracted from the tissue of progenies which are derived by mating the transgenic fish and wild-type counterpart.  This method needs relatively large amounts of fish material and is time- and labor-intensive. New approaches addressing this problem could be of great help for fish biotechnologists.  In this experiment, we applied a quantitative real-time PCR (qr-PCR method to analyze zygosity in a stable line of transgenic zebrafish (Danio rerio carrying masu salmon, Oncorhynchus masou D6-desaturase-like gene. The qr-PCR was performed using iQ SYBR Green Supermix in the iCycler iQ Real-time PCR Detection System (Bio-Rad Laboratories, USA.  Data were analyzed using the comparative cycle threshold method.  The results demonstrated a clear-cut identification of all transgenic fish (n=20 classified as a homozygous or heterozygous.  Mating of those fish with wild-type had revealed transgene transmission to the offspring following expected Mendelian laws. Thus, we found that the qTR-PCR to be effective for a rapid and precise determination of zygosity in transgenic fish. This technique could be useful in the establishment of breeding programs for mass transgenic fish production and in experiments in which zygosity effect could have a functional impact. Keywords: quantitative real-time PCR; zygosity; transgenic fish; mass production   ABSTRAK Identifikasi sigositas ikan transgenik biasanya dilakukan menggunakan analisa PCR dengan cetakan DNA genomik yang diekstraksi dari jaringan ikan hasil persilangan antara ikan transgenik dan ikan normal.   Metode ini memerlukan ikan dalam jumlah yang banyak, dan juga waktu serta tenaga.  Pendekatan baru untuk mengatasi masalah tersebut akan memberikan manfaat besar kepada peneliti bioteknologi perikanan.  Pada penelitian ini, kami menggunakan metode PCR real-time kuantitatif (krt-PCR untuk

  14. Petrifilm rapid S. aureus Count Plate method for rapid enumeration of Staphylococcus aureus in selected foods: collaborative study.

    Science.gov (United States)

    Silbernagel, K M; Lindberg, K G

    2001-01-01

    A rehydratable dry-film plating method for Staphylococcus aureus in foods, the 3M Petrifilm Rapid S. aureus Count Plate method, was compared with AOAC Official Method 975.55 (Staphylococcus aureus in Foods). Nine foods-instant nonfat dried milk, dry seasoned vegetable coating, frozen hash browns, frozen cooked chicken patty, frozen ground raw pork, shredded cheddar cheese, fresh green beans, pasta filled with beef and cheese, and egg custard-were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample and 3 levels of inoculated test sample, each in duplicate. The mean log counts for the methods were comparable for pasta filled with beef and cheese; frozen hash browns; cooked chicken patty; egg custard; frozen ground raw pork; and instant nonfat dried milk. The repeatability and reproducibility variances of the Petrifilm Rapid S. aureus Count Plate method were similar to those of the standard method.

  15. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  16. Rapid filling of pipelines with the SPH particle method

    NARCIS (Netherlands)

    Hou, Q.; Zhang, L.X.; Tijsseling, A.S.; Kruisbrink, A.C.H.

    2011-01-01

    The paper reports the development and application of a SPH (smoothed particle hydrodynamics) based simulation of rapid filling of pipelines, for which the rigid-column model is commonly used. In this paper the water-hammer equations with a moving boundary are used to model the pipe filling process,

  17. Rapid filling of pipelines with the SPH particle method

    NARCIS (Netherlands)

    Hou, Q.; Zhang, L.X.; Tijsseling, A.S.; Kruisbrink, A.C.H.

    2012-01-01

    The paper reports the development and application of a SPH (smoothed particle hydrodynamics) based simulation of rapid filling of pipelines, for which the rigid-column model is commonly used. In this paper the water-hammer equations with a moving boundary are used to model the pipe filling process,

  18. Study of a new radiometric sterility test in radiopharmaceuticals

    International Nuclear Information System (INIS)

    Sanchez P, A.R.

    1976-01-01

    A new radiometric method is studied for the determination of sterility. It is based on a culture marked with carbon-14 and the measurement by liquid scintillation of the radioactivity of the gaseous products released after a short period of incubation. The studied samples consisted in nonradioactive solutions and different radiopharmaceuticals, through a regulated current of nitrogen there is a transportation of gaseous and volatile products produced in each flask, which were received in a liquid scintillation vial. The experimental data permit to conclude that through the radiometric method the results can be obtained after 24 hours or less of incubation, instead of a period of several days which was necessary with the traditional process. Due to the sensitivity of the method it is possible to inoculate a minimum volume of sample, this is important in the case of the preparation of little parts for injection as it occurs generally with the pharmaceuticals. (author)

  19. Radiometric Correction of Close-Range Spectral Image Blocks Captured Using an Unmanned Aerial Vehicle with a Radiometric Block Adjustment

    Directory of Open Access Journals (Sweden)

    Eija Honkavaara

    2018-02-01

    Full Text Available Unmanned airborne vehicles (UAV equipped with novel, miniaturized, 2D frame format hyper- and multispectral cameras make it possible to conduct remote sensing measurements cost-efficiently, with greater accuracy and detail. In the mapping process, the area of interest is covered by multiple, overlapping, small-format 2D images, which provide redundant information about the object. Radiometric correction of spectral image data is important for eliminating any external disturbance from the captured data. Corrections should include sensor, atmosphere and view/illumination geometry (bidirectional reflectance distribution function—BRDF related disturbances. An additional complication is that UAV remote sensing campaigns are often carried out under difficult conditions, with varying illumination conditions and cloudiness. We have developed a global optimization approach for the radiometric correction of UAV image blocks, a radiometric block adjustment. The objective of this study was to implement and assess a combined adjustment approach, including comprehensive consideration of weighting of various observations. An empirical study was carried out using imagery captured using a hyperspectral 2D frame format camera of winter wheat crops. The dataset included four separate flights captured during a 2.5 h time period under sunny weather conditions. As outputs, we calculated orthophoto mosaics using the most nadir images and sampled multiple-view hyperspectral spectra for vegetation sample points utilizing multiple images in the dataset. The method provided an automated tool for radiometric correction, compensating for efficiently radiometric disturbances in the images. The global homogeneity factor improved from 12–16% to 4–6% with the corrections, and a reduction in disturbances could be observed in the spectra of the object points sampled from multiple overlapping images. Residuals in the grey and white reflectance panels were less than 5% of the

  20. The Radiometric Bode's law and Extrasolar Planets

    National Research Council Canada - National Science Library

    Lazio, T. J; Farrell, W. M; Dietrick, Jill; Greenlees, Elizabeth; Hogan, Emily; Jones, Christopher; Hennig, L. A

    2004-01-01

    We predict the radio flux densities of the extrasolar planets in the current census, making use of an empirical relation the radiometric Bode's law determined from the five "magnetic" planets in the solar system...

  1. Ash content of lignites - radiometric analysis

    International Nuclear Information System (INIS)

    Leonhardt, J.; Thuemmel, H.W.

    1986-01-01

    The quality of lignites is governed by the ash content varying in dependence upon the geologic conditions. Setup and function of the radiometric devices being used for ash content analysis in the GDR are briefly described

  2. Modified and reverse radiometric flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Ba, H; Khin, M M; Aung, K; Thida, [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-06-01

    Determination of [sup 137]Cs and [sup 60]Co by using modified and reverse radiometric flow injection analysis is described. Two component RFIA was also realized using [sup 60]Co and [sup 137]Cs radionuclides. (author) 2 refs.; 5 figs.

  3. Radiometric and signal-to-noise ratio properties of multiplex dispersive spectrometry

    International Nuclear Information System (INIS)

    Barducci, Alessandro; Guzzi, Donatella; Lastri, Cinzia; Nardino, Vanni; Marcoionni, Paolo; Pippi, Ivan

    2010-01-01

    Recent theoretical investigations have shown important radiometric disadvantages of interferential multiplexing in Fourier transform spectrometry that apparently can be applied even to coded aperture spectrometers. We have reexamined the methods of noninterferential multiplexing in order to assess their signal-to-noise ratio (SNR) performance, relying on a theoretical modeling of the multiplexed signals. We are able to show that quite similar SNR and radiometric disadvantages affect multiplex dispersive spectrometry. The effect of noise on spectral estimations is discussed.

  4. Development of Radiometric and Allied Analytical Methods and Strategies to Strengthen National Residue Control Programmes for Antibiotic and Anthelmintic Veterinary Drug Residues. Final Report of a Coordinated Research Project

    International Nuclear Information System (INIS)

    2016-08-01

    Awareness of food safety is rising among consumers, and many importing countries implement food control regulations to guarantee the quality and safety of imported foods for their consumers. Many developing countries have also taken steps to put in place control systems that encourage responsible use of veterinary medicines to combat possible drug resistance, control drug residues and ensure compliance with international and national standards. However, these countries still require the necessary know-how and skills to protect local consumers and to access international markets. One significant constraint is the capacity of laboratory services to generate surveillance data using reliable and cost effective analytical methods validated to national and international standards. The IAEA coordinated research project (CRP) on the Development of Radiometric and Allied Analytical Methods to Strengthen National Residue Control Programmes for Antibiotic and Anthelmintic Veterinary Drug Residues was initiated in 2009 to conduct work on robust nuclear and related technologies suitable for the screening and confirmatory analysis of residues of veterinary medicines, including antimicrobials and anthelmintics commonly used in animal production, with public health and trade significance. The CRP also explored mechanisms to enhance networking among research institutions involved in research on pharmacologically active veterinary drug residues in food (primarily) and environmental samples. The project was implemented by the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture between 2009 and 2014 and involved eleven research contracts and one technical contract, five research agreements and one institution. The CRP was a continuation of the CRP on the Development of Strategies for the Effective Monitoring of Veterinary Drug Residues in Livestock and Livestock Products in Developing Countries and the key findings are also summarized in this publication.

  5. RADIOMETRIC CALIBRATION OF AIRBORNE LASER SCANNING DATA

    OpenAIRE

    Pilarska Magdalena

    2016-01-01

    Airborne laser scanning (ALS) is widely used passive remote sensing technique. The radiometric calibration of ALS data is presented in this article. This process is a necessary element in data processing since it eliminates the influence of the external factors on the obtained values of radiometric features such as range and incidence angle. The datasets were captured with three different laser scanners; since each of these operates at a different wavelength (532, 106 4 and 1550 nm) th...

  6. A rapid method to estimate Westergren sedimentation rates.

    Science.gov (United States)

    Alexy, Tamas; Pais, Eszter; Meiselman, Herbert J

    2009-09-01

    The erythrocyte sedimentation rate (ESR) is a nonspecific but simple and inexpensive test that was introduced into medical practice in 1897. Although it is commonly utilized in the diagnosis and follow-up of various clinical conditions, ESR has several limitations including the required 60 min settling time for the test. Herein we introduce a novel use for a commercially available computerized tube viscometer that allows the accurate prediction of human Westergren ESR rates in as little as 4 min. Owing to an initial pressure gradient, blood moves between two vertical tubes through a horizontal small-bore tube and the top of the red blood cell (RBC) column in each vertical tube is monitored continuously with an accuracy of 0.083 mm. Using data from the final minute of a blood viscosity measurement, a sedimentation index (SI) was calculated and correlated with results from the conventional Westergren ESR test. To date, samples from 119 human subjects have been studied and our results indicate a strong correlation between SI and ESR values (R(2)=0.92). In addition, we found a close association between SI and RBC aggregation indices as determined by an automated RBC aggregometer (R(2)=0.71). Determining SI on human blood is rapid, requires no special training and has minimal biohazard risk, thus allowing physicians to rapidly screen for individuals with elevated ESR and to monitor therapeutic responses.

  7. Radiometric-microbiologic assay fo vitamin B-6: analysis of plasma samples

    International Nuclear Information System (INIS)

    Guilarte, T.R.; McIntyre, P.A.

    1981-01-01

    A radiometric microbiologic assay for the analysis of vitamin B-6 in plasma was developed. The method is based on the measurement of 14CO2 generated from the metabolism of DL-l-14C-valine (L-l-14C-valine) by Kloeckera brevis. The assay is specific for the biologically active forms of the vitamin, that is, pyridoxine, pyridoxal and pyridoxamine, and their respective phosphorylated forms. The biologically inert vitamin B-6 metabolite (4-pyridoxic acid) did not generate a response at concentrations tested. The radiometric technique was shown to be sensitive to the 1 nanogram level. Reproducibility and recovery studies gave good results. Fifteen plasma samples were assayed using the radiometric and turbidimetric techniques. The correlation coefficient was r . 0.98. Turbid material or precipitated debris did not interfere with the radiometric microbiologic assay, thus allowing for simplification of assay procedure

  8. Simplified Method for Rapid Purification of Soluble Histones

    Directory of Open Access Journals (Sweden)

    Nives Ivić

    2016-06-01

    Full Text Available Functional and structural studies of histone-chaperone complexes, nucleosome modifications, their interactions with remodelers and regulatory proteins rely on obtaining recombinant histones from bacteria. In the present study, we show that co-expression of Xenopus laevis histone pairs leads to production of soluble H2AH2B heterodimer and (H3H42 heterotetramer. The soluble histone complexes are purified by simple chromatographic techniques. Obtained H2AH2B dimer and H3H4 tetramer are proficient in histone chaperone binding and histone octamer and nucleosome formation. Our optimized protocol enables rapid purification of multiple soluble histone variants with a remarkable high yield and simplifies histone octamer preparation. We expect that this simple approach will contribute to the histone chaperone and chromatin research. This work is licensed under a Creative Commons Attribution 4.0 International License.

  9. Evaluating an alternative method for rapid urinary creatinine determination

    Science.gov (United States)

    Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...

  10. Rapid and Reliable HPLC Method for the Determination of Vitamin ...

    African Journals Online (AJOL)

    Purpose: To develop and validate an accurate, sensitive and reproducible high performance liquid chromatographic (HPLC) method for the quantitation of vitamin C in pharmaceutical samples. Method: The drug and the standard were eluted from Superspher RP-18 (250 mm x 4.6 mm, 10ìm particle size) at 20 0C.

  11. A rapid method for determining chlorobenzenes in dam water systems

    African Journals Online (AJOL)

    A method using direct immersion solid phase microextraction (DI-SPME) coupled to gas chromatography equipped with a flame ionisation detector (GC-FID) was developed for the analysis of 7 chlorinated benzenes in dam water. The main parameters affecting the DI-SPME process were optimised. The optimised method ...

  12. RESEARCH NOTE A Universal, rapid, and inexpensive method for ...

    Indian Academy of Sciences (India)

    Navya

    success of the extracted gDNA to be submitted into post-PCR analysis. ... The application of the universal method for DNA extraction not restricted into routine ... On the other hand, the universal method has proven its feasibility to be utilized.

  13. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  14. Liquid scintillation vial for radiometric assay of lymphocyte carbohydrate metabolism in response to mitogens

    International Nuclear Information System (INIS)

    Tran, N.; Wagner, H.N. Jr.

    1978-01-01

    We have demonstrated that mitogens--i.e., PHA and Con.A--stimulate lymphocyte carbohydrate metabolism using a liquid-scintillation vial with conventional liquid-scintillation detectors. The results showed that this enclosed system can be useful for development of rapid in vitro tests of lymphocytes immune responsiveness, as well as for radiometric detection of bacterial growth in various gaseous atmospheres

  15. Rapid separation method for {sup 237}Np and Pu isotopes in large soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod L., E-mail: sherrod.maxwell@srs.go [Savannah River Nuclear Solutions, LLC, Building 735-B, Aiken, SC 29808 (United States); Culligan, Brian K.; Noyes, Gary W. [Savannah River Nuclear Solutions, LLC, Building 735-B, Aiken, SC 29808 (United States)

    2011-07-15

    A new rapid method for the determination of {sup 237}Np and Pu isotopes in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for large soil samples. The new soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates are used to reduce analytical time.

  16. A simple and rapid molecular method for Leptospira species identification

    NARCIS (Netherlands)

    Ahmed, Ahmed; Anthony, Richard M.; Hartskeerl, Rudy A.

    2010-01-01

    Serological and DNA-based classification systems only have little correlation. Currently serological and molecular methods for characterizing Leptospira are complex and costly restricting their world-wide distribution and use. Ligation mediated amplification combined with microarray analysis

  17. Rapid and inexpensive method for isolating plasmid DNA

    International Nuclear Information System (INIS)

    Aljanabi, S. M.; Al-Awadi, S. J.; Al-Kazaz, A. A.; Baghdad Univ.

    1997-01-01

    A small-scale and economical method for isolating plasmid DNA from bacteria is described. The method provides DNA of suitable quality for most DNA manipulation techniques. This DNA can be used for restriction endonuclease digestion, southern blot hybridization, nick translation and end labeling of DNA probes, Polymerase Chain Reaction (PCR) -based techniques, transformation, DNA cycle-sequencing, and Chain-termination method for DNA sequencing. The entire procedure is adapted to 1.5 ml microfuge tubes and takes approximately 30 mins. The DNA isolated by this method has the same purity produced by CTAB and cesium chloride precipitation and purification procedures respectively. The two previous methods require many hours to obtain the final product and require the use of very expensive equipment as ultracentrifuge. This method is well suited for the isolation of plasmid DNA from a large number of bacterial samples and in a very short time and low cost in laboratories where chemicals, expensive equipment and finance are limited factors in conducting molecular research. (authors). 11refs. 11refs

  18. MASS SPECTROMETRY PROTEOMICS METHOD AS A RAPID SCREENING TOOL FOR BACTERIAL CONTAMINATION OF FOOD

    Science.gov (United States)

    2017-06-01

    MASS SPECTROMETRY PROTEOMICS METHOD AS A RAPID SCREENING TOOL FOR BACTERIAL CONTAMINATION OF FOOD ECBC-TR...TITLE AND SUBTITLE Mass Spectrometry Proteomics Method as a Rapid Screening Tool for Bacterial Contamination of Food 5a. CONTRACT NUMBER 5b...the MSPM to correctly classify whether or not food samples were contaminated with Salmonella enterica serotype Newport in this blinded pilot study

  19. Rapid, cost-effective liquid chromatograghic method for the ...

    African Journals Online (AJOL)

    GRACE

    2006-07-03

    Jul 3, 2006 ... The method was validated and used for pharmacokinetic studies. Key words: Metronidazole ... by the intrinsic analytical properties of the drug molecule ... In addition, such factors as sample size ... account, since these affect the reliability of the quantitation. ... phase and ion-pair high–performance liquid.

  20. Rapid multi-residue method for the determination of pesticide ...

    African Journals Online (AJOL)

    Exposure to pesticides can represent a potential risk to humans. Agricultural workers are at risk of chronic toxicity. Hence, the evaluation of pesticide residues in their blood gives an indication about the extent of exposure and help in assessing adverse health effects. The aim of our study was to develop analytical method for ...

  1. A universal, rapid, and inexpensive method for genomic DNA ...

    Indian Academy of Sciences (India)

    MOHAMMED BAQUR SAHIB A. AL-SHUHAIB

    gels, containing 7% glycerol, and 1×TBE buffer. The gels were run under 200 .... Inc. Germany, GeneaidTM DNA Isolation Kit, Geneaid. Biotech., New Taipei City, .... C. L. and Arsenos G. 2015 Comparison of eleven methods for genomic DNA ...

  2. Rapid prototyping methods for the manufacture of fuel cells

    Directory of Open Access Journals (Sweden)

    Dudek Piotr

    2016-01-01

    The potential for the application of this method for the manufacture of metallic bipolar plates (BPP for use in proton exchange membrane fuel cells (PEMFCs is presented and discussed. Special attention is paid to the fabrication of light elements for the construction of PEMFC stacks designed for mobile applications such as aviation technology and unmanned aerial vehicles (UAVs.

  3. Determination of mycroplasmic contamination by radiometric method

    International Nuclear Information System (INIS)

    Khashimova, Z.S.

    2004-01-01

    Full text: Some species of mycoplasmas are pathogenic for man, animals and plants. The problem of mycoplasmic contamination of cultivated cells used in biotechnology for producing of monoclonal antibodies and vaccines is very actual. The plasmatic membrane of mycoplasmas, which does not differ on its structural organization from a membrane of eucariotic cells, takes part in formation of strong surface antigens. Taking into account this fact, it has been investigated mycoplasmic contamination of several kinds of cotton seeds, myelome cells XAg8.653, and hybridoma cells producing monoclonal antibodies to cotton membrane proteins. Mycoplasmic contamination was determined by hybridization of DNA of investigated objects with recombinant plasmids containing mycoplasmas DNA fragments. DNA was isolated from 5 kinds of cotton seedling, cellular cultures and hybridomas according to standard protocols. DNA was denaturated, neutralized and a reaction mix was transferred to nitrocellulose filter. Than filters were hybridizated with universal plasmid sounds namely pMg16 and pAl32, which contained the mycoplasma genomic fragment. These sounds were constructed in the Institute of Cytology of Russian Academy of Science by Borhsenius S.N. at al. [1] and kindly given us for our work. pMg16 and pAl32 were preliminary marked by 32 P - ATP (nick - translation). Hybridization was carried out within night. Filters were washed and placed for radioautography at - 70 o C for 24h. Sensitivity of 32 P - labeled probes in reaction was 1ng of mycoplasmas DNA. It was shown, that only one kind of cotton seeds was not contaminated by mycoplasmas, and hybridoma and myeloma cells was not contaminated. Thus, the presence of mycoplasmas in different objects may be determined using DNA hybridization. This work was supported by the Center of Science and Technology RU (4F No 419)

  4. The Most Probable Limit of Detection (MPL) for rapid microbiological methods

    NARCIS (Netherlands)

    Verdonk, G.P.H.T.; Willemse, M.J.; Hoefs, S.G.G.; Cremers, G.; Heuvel, E.R. van den

    Classical microbiological methods have nowadays unacceptably long cycle times. Rapid methods, available on the market for decades, are already applied within the clinical and food industry, but the implementation in pharmaceutical industry is hampered by for instance stringent regulations on

  5. The most probable limit of detection (MPL) for rapid microbiological methods

    NARCIS (Netherlands)

    Verdonk, G.P.H.T.; Willemse, M.J.; Hoefs, S.G.G.; Cremers, G.; Heuvel, van den E.R.

    2010-01-01

    Classical microbiological methods have nowadays unacceptably long cycle times. Rapid methods, available on the market for decades, are already applied within the clinical and food industry, but the implementation in pharmaceutical industry is hampered by for instance stringent regulations on

  6. Optimal control methods for rapidly time-varying Hamiltonians

    International Nuclear Information System (INIS)

    Motzoi, F.; Merkel, S. T.; Wilhelm, F. K.; Gambetta, J. M.

    2011-01-01

    In this article, we develop a numerical method to find optimal control pulses that accounts for the separation of timescales between the variation of the input control fields and the applied Hamiltonian. In traditional numerical optimization methods, these timescales are treated as being the same. While this approximation has had much success, in applications where the input controls are filtered substantially or mixed with a fast carrier, the resulting optimized pulses have little relation to the applied physical fields. Our technique remains numerically efficient in that the dimension of our search space is only dependent on the variation of the input control fields, while our simulation of the quantum evolution is accurate on the timescale of the fast variation in the applied Hamiltonian.

  7. Time evolution of the wave equation using rapid expansion method

    KAUST Repository

    Pestana, Reynam C.; Stoffa, Paul L.

    2010-01-01

    Forward modeling of seismic data and reverse time migration are based on the time evolution of wavefields. For the case of spatially varying velocity, we have worked on two approaches to evaluate the time evolution of seismic wavefields. An exact solution for the constant-velocity acoustic wave equation can be used to simulate the pressure response at any time. For a spatially varying velocity, a one-step method can be developed where no intermediate time responses are required. Using this approach, we have solved for the pressure response at intermediate times and have developed a recursive solution. The solution has a very high degree of accuracy and can be reduced to various finite-difference time-derivative methods, depending on the approximations used. Although the two approaches are closely related, each has advantages, depending on the problem being solved. © 2010 Society of Exploration Geophysicists.

  8. Time evolution of the wave equation using rapid expansion method

    KAUST Repository

    Pestana, Reynam C.

    2010-07-01

    Forward modeling of seismic data and reverse time migration are based on the time evolution of wavefields. For the case of spatially varying velocity, we have worked on two approaches to evaluate the time evolution of seismic wavefields. An exact solution for the constant-velocity acoustic wave equation can be used to simulate the pressure response at any time. For a spatially varying velocity, a one-step method can be developed where no intermediate time responses are required. Using this approach, we have solved for the pressure response at intermediate times and have developed a recursive solution. The solution has a very high degree of accuracy and can be reduced to various finite-difference time-derivative methods, depending on the approximations used. Although the two approaches are closely related, each has advantages, depending on the problem being solved. © 2010 Society of Exploration Geophysicists.

  9. Study of a large rapid ashing apparatus and a rapid dry ashing method for biological samples and its application

    International Nuclear Information System (INIS)

    Jin Meisun; Wang Benli; Liu Wencang

    1988-04-01

    A large rapid-dry-ashing apparatus and a rapid ashing method for biological samples are described. The apparatus consists of specially made ashing furnace, gas supply system and temperature-programming control cabinet. The following adventages have been showed by ashing experiment with the above apparatus: (1) high speed of ashing and saving of electric energy; (2) The apparatus can ash a large amount of samples at a time; (3) The ashed sample is pure white (or spotless), loose and easily soluble with few content of residual char; (4) The fresh sample can also be ashed directly. The apparatus is suitable for ashing a large amount of the environmental samples containing low level radioactivity trace elements and the medical, food and agricultural research samples

  10. A multiplex PCR method for rapid identification of Brachionus rotifers.

    Science.gov (United States)

    Vasileiadou, Kalliopi; Papakostas, Spiros; Triantafyllidis, Alexander; Kappas, Ilias; Abatzopoulos, Theodore J

    2009-01-01

    Cryptic species are increasingly being recognized in many organisms. In Brachionus rotifers, many morphologically similar yet genetically distinct species/biotypes have been described. A number of Brachionus cryptic species have been recognized among hatchery strains. In this study, we present a simple, one-step genetic method to detect the presence of those Brachionus sp. rotifers that have been found in hatcheries. With the proposed technique, each of the B. plicatilis sensu stricto, B. ibericus, Brachionus sp. Nevada, Brachionus sp. Austria, Brachionus sp. Manjavacas, and Brachionus sp. Cayman species and/or biotypes can be identified with polymerase chain reaction (PCR) analysis. Based on 233 cytochrome c oxidase subunit I sequences, we reviewed all the available cryptic Brachionus sp. genetic polymorphisms, and we designed six nested primers. With these primers, a specific amplicon of distinct size is produced for every one of the involved species/biotypes. Two highly sensitive protocols were developed for using the primers. Many of the primers can be combined in the same PCR. The proposed method has been found to be an effective and practical tool to investigate the presence of the above six cryptic species/biotypes in both individual and communal (bulk) rotifer deoxyribonucleic acid extractions from hatcheries. With this technique, hatchery managers could easily determine their rotifer composition at the level of cryptic species and monitor their cultures more efficiently.

  11. Panay carborne radiometric and geochemical surveys

    International Nuclear Information System (INIS)

    Santos, G. Jr.

    1981-09-01

    A carborne radiometric survey and stream sediments collection were conducted in Panay and Guimaras Islands. An area in Nabas, Aklan, situated in the northwestern tip of Panay (Buruanga Peninsula) which indicated 2 to 3 times above background radioactivity was delineated. Uranium content in the stream sediment samples collected from Buruanga Peninsula was generally higher than those obtained in other parts of the island. Radioactivity measurements and uranium content in stream sediments were found to be within background levels. It is recommended that follow-up radiometric and geochemical surveys be undertaken in Buruanga Peninsula and additional stream sediments samples be collected in Panay to achieve better sampling density and coverage. (author)

  12. Radiometric study of creep in ingot rolling

    International Nuclear Information System (INIS)

    Kubicek, P.; Zamyslovsky, Z.; Uherek, J.

    The radiometric study of creep during ingot rolling performed in the rolling mill of the Vitkovice Iron and Steel Works and the first results are described. Selected sites in 3 to 8 ton ingots were labelled with 2 to 3.7x10 5 Bq of 60 Co and after rolling into blocks, the transposition of the labelled sites of the ingots was investigated. The results indicate creep during rolling, local extension in certain sites under study and help to determine the inevitable bottom crop incurred in the forming. Finally, the requirements put on the radiometric apparatus for the next stages of technological research are presented. (author)

  13. The Use of Rapid Review Methods for the U.S. Preventive Services Task Force.

    Science.gov (United States)

    Patnode, Carrie D; Eder, Michelle L; Walsh, Emily S; Viswanathan, Meera; Lin, Jennifer S

    2018-01-01

    Rapid review products are intended to synthesize available evidence in a timely fashion while still meeting the needs of healthcare decision makers. Various methods and products have been applied for rapid evidence syntheses, but no single approach has been uniformly adopted. Methods to gain efficiency and compress the review time period include focusing on a narrow clinical topic and key questions; limiting the literature search; performing single (versus dual) screening of abstracts and full-text articles for relevance; and limiting the analysis and synthesis. In order to maintain the scientific integrity, including transparency, of rapid evidence syntheses, it is imperative that procedures used to streamline standard systematic review methods are prespecified, based on sound review principles and empiric evidence when possible, and provide the end user with an accurate and comprehensive synthesis. The collection of clinical preventive service recommendations maintained by the U.S. Preventive Services Task Force, along with its commitment to rigorous methods development, provide a unique opportunity to refine, implement, and evaluate rapid evidence synthesis methods and add to an emerging evidence base on rapid review methods. This paper summarizes the U.S. Preventive Services Task Force's use of rapid review methodology, its criteria for selecting topics for rapid evidence syntheses, and proposed methods to streamline the review process. Copyright © 2018 American Journal of Preventive Medicine. All rights reserved.

  14. RADIOMETRIC TECHNIQUES IN HEAVY MINERAL EXPLORATION AND EXPLOITATION

    NARCIS (Netherlands)

    DEMEIJER, RJ; TANCZOS, IC; STAPEL, C

    1994-01-01

    In recent years the Environmental Research Group of the KVI has been developing a number of radiometric techniques that may be employed in mineral sand exploration. These techniques involve: radiometric fingerprinting for assessing sand provenances and mineralogical composition; thermoluminescence

  15. Rapid Methods for the Detection of Foodborne Bacterial Pathogens: Principles, Applications, Advantages and Limitations

    Directory of Open Access Journals (Sweden)

    Law eJodi Woan-Fei

    2015-01-01

    Full Text Available The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR, multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA, loop-mediated isothermal amplification (LAMP and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases.

  16. THE EUROSDR PROJECT "RADIOMETRIC ASPECTS OF DIGITAL PHOTOGRAMMETRIC IMAGES" – RESULTS OF THE EMPIRICAL PHASE

    Directory of Open Access Journals (Sweden)

    E. Honkavaara

    2012-09-01

    Full Text Available This article presents the empirical research carried out in the context of the multi-site EuroSDR project "Radiometric aspects of digital photogrammetric images" and provides highlights of the results. The investigations have considered the vicarious radiometric and spatial resolution validation and calibration of the sensor system, radiometric processing of the image blocks either by performing relative radiometric block equalization or into absolutely reflectance calibrated products, and finally aspects of practical applications on NDVI layer generation and tree species classification. The data sets were provided by Leica Geosystems ADS40 and Intergraph DMC and the participants represented stakeholders in National Mapping Authorities, software development and research. The investigations proved the stability and quality of evaluated imaging systems with respect to radiometry and optical system. The first new-generation methods for reflectance calibration and equalization of photogrammetric image block data provided promising accuracy and were also functional from the productivity and usability points of view. The reflectance calibration methods provided up to 5% accuracy without any ground reference. Application oriented results indicated that automatic interpretation methods will benefit from the optimal use of radiometrically accurate multi-view photogrammetric imagery.

  17. Methods and Magnitudes of Rapid Weight Loss in Judo Athletes Over Pre-Competition Periods

    Directory of Open Access Journals (Sweden)

    Kons Rafael Lima

    2017-06-01

    Full Text Available Purpose. The study aimed to analyse the methods and magnitudes of rapid weight loss (RWL in judo team members in distinct periods before the biggest state competition in Southern Brazil.

  18. Interconnection blocks: a method for providing reusable, rapid, multiple, aligned and planar microfluidic interconnections

    DEFF Research Database (Denmark)

    Sabourin, David; Snakenborg, Detlef; Dufva, Hans Martin

    2009-01-01

    In this paper a method is presented for creating 'interconnection blocks' that are re-usable and provide multiple, aligned and planar microfluidic interconnections. Interconnection blocks made from polydimethylsiloxane allow rapid testing of microfluidic chips and unobstructed microfluidic observ...

  19. Mobile Image Ratiometry: A New Method for Instantaneous Analysis of Rapid Test Strips

    OpenAIRE

    Donald C. Cooper; Bryan Callahan; Phil Callahan; Lee Burnett

    2012-01-01

    Here we describe Mobile Image Ratiometry (MIR), a new method for the automated quantification of standardized rapid immunoassay strips using consumer-based mobile smartphone and tablet cameras. To demonstrate MIR we developed a standardized method using rapid immunotest strips directed against cocaine (COC) and its major metabolite, benzoylecgonine (BE). We performed image analysis of three brands of commercially available dye-conjugated anti-COC/BE antibody test strips in response to three d...

  20. [Rapid methods for the genus Salmonella bacteria detection in food and raw materials].

    Science.gov (United States)

    Sokolov, D M; Sokolov, M S

    2013-01-01

    The article considers sanitary and epidemiological aspects and the impact of Salmonella food poisoning in Russia and abroad. The main characteristics of the agent (Salmonella enterica subsp. Enteritidis) are summarized. The main sources of human Salmonella infection are products of poultry and livestock (poultry, eggs, dairy products, meat products, etc.). Standard methods of identifying the causative agent, rapid (alternative) methods of analysis of Salmonella using differential diagnostic medium (MSRV, Salmosyst, XLT4-agar, agar-Rambach et al.), rapid tests Singlepath-Salmonella and PCR (food proof Salmonella) in real time were stated. Rapid tests provide is a substantial (at 24-48 h) reducing the time to identify Salmonella.

  1. The determination of Sr-90 in environmental material using an improved rapid method

    International Nuclear Information System (INIS)

    Ghods, A.; Veselsky, J.C.; Zhu, S.; Mirna, A.; Schelenz, R.

    1989-01-01

    A short report on strontium 90, its occurrence in the biosphere and its rapid determination methods is given. Classification of determination methods suitable for various environmental and biological materials is established. Interference due to Y-91 and a method to eliminate the activity of Y-90 and Y-91 is discussed. Tabs

  2. Rapid identification of salmonella serotypes with stereo and hyperspectral microscope imaging Methods

    Science.gov (United States)

    The hyperspectral microscope imaging (HMI) method can reduce detection time within 8 hours including incubation process. The early and rapid detection with this method in conjunction with the high throughput capabilities makes HMI method a prime candidate for implementation for the food industry. Th...

  3. Remote sensing, airborne radiometric survey and aeromagnetic survey data processing and analysis

    International Nuclear Information System (INIS)

    Dong Xiuzhen; Liu Dechang; Ye Fawang; Xuan Yanxiu

    2009-01-01

    Taking remote sensing data, airborne radiometric data and aero magnetic survey data as an example, the authors elaborate about basic thinking of remote sensing data processing methods, spectral feature analysis and adopted processing methods, also explore the remote sensing data combining with the processing of airborne radiometric survey and aero magnetic survey data, and analyze geological significance of processed image. It is not only useful for geological environment research and uranium prospecting in the study area, but also reference to applications in another area. (authors)

  4. Vicarious absolute radiometric calibration of GF-2 PMS2 sensor using permanent artificial targets in China

    Science.gov (United States)

    Liu, Yaokai; Li, Chuanrong; Ma, Lingling; Wang, Ning; Qian, Yonggang; Tang, Lingli

    2016-10-01

    GF-2, launched on August 19 2014, is one of the high-resolution land resource observing satellite of the China GF series satellites plan. The radiometric performance evaluation of the onboard optical pan and multispectral (PMS2) sensor of GF-2 satellite is very important for the further application of the data. And, the vicarious absolute radiometric calibration approach is one of the most useful way to monitor the radiometric performance of the onboard optical sensors. In this study, the traditional reflectance-based method is used to vicarious radiometrically calibrate the onboard PMS2 sensor of GF-2 satellite using three black, gray and white reflected permanent artificial targets located in the AOE Baotou site in China. Vicarious field calibration campaign were carried out in the AOE-Baotou calibration site on 22 April 2016. And, the absolute radiometric calibration coefficients were determined with in situ measured atmospheric parameters and surface reflectance of the permanent artificial calibration targets. The predicted TOA radiance of a selected desert area with our determined calibrated coefficients were compared with the official distributed calibration coefficients. Comparison results show a good consistent and the mean relative difference of the multispectral channels is less than 5%. Uncertainty analysis was also carried out and a total uncertainty with 3.87% is determined of the TOA radiance.

  5. Synthesis, radiometric determination of functional groups, complexation

    International Nuclear Information System (INIS)

    Pompe, S.; Bubner, M.; Schmeide, K.; Heise, K.H.; Bernhard, G.; Nitsche, H.

    2000-01-01

    The interaction behavior of humic acids with uranium(VI) and the influence of humic substances on the migration behavior of uranium was investigated. A main focus of this work was the synthesis of four different humic acid model substances and their characterization and comparison to the natural humic acid from Aldrich. A radiometric method for the determination of humic acid functional groups was applied in addition to conventional methods for the determination of the functionality of humic acids. The humic acid model substances show functional and structural properties comparable to natural humic acids. Modified humic acids with blocked phenolic OH were synthesized to determine the influence of phenolic OH groups on the complexation behavior of humic acids. A synthesis method for 14 C-labeled humic acids with high specific activity was developed. The complexation behavior of synthetic and natural humic acids with uranium(VI) was investigated by X-ray absorption spectroscopy, laser-induced fluorescence spectroscopy and FTIR spectroscopy. The synthetic model substances show an interaction behavior with uranium(VI) that is comparable to natural humic acids. This points to the fact that the synthetic humic acids simulate the functionality of their natural analogues very well. For the first time the influence of phenolic OH groups on the complexation behavior of humic acids was investigated by applying a modified humic acid with blocked phenolic OH groups. The formation of a uranyl hydroxy humate complex was identified by laserspectroscopic investigations of the complexation of Aldrich humic acid with uranium(VI) at pH 7. The migration behavior of uranium in a sandy aquifer system rich is humic substances was investigated in column experiments. A part of uranium migrates non-retarded through the sediment, bound to humic colloids. The uranium migration behavior is strongly influenced by the kinetically controlled interaction processes of uranium with the humic colloids

  6. The scope of application of incremental rapid prototyping methods in foundry engineering

    Directory of Open Access Journals (Sweden)

    M. Stankiewicz

    2010-01-01

    Full Text Available The article presents the scope of application of selected incremental Rapid Prototyping methods in the process of manufacturing casting models, casting moulds and casts. The Rapid Prototyping methods (SL, SLA, FDM, 3DP, JS are predominantly used for the production of models and model sets for casting moulds. The Rapid Tooling methods, such as: ZCast-3DP, ProMetalRCT and VoxelJet, enable the fabrication of casting moulds in the incremental process. The application of the RP methods in cast production makes it possible to speed up the prototype preparation process. This is particularly vital to elements of complex shapes. The time required for the manufacture of the model, the mould and the cast proper may vary from a few to several dozen hours.

  7. Radiometric characterization of Landsat Collection 1 products

    Science.gov (United States)

    Micijevic, Esad; Haque, Md. Obaidul; Mishra, Nischal

    2017-09-01

    Landsat data in the U.S. Geological Survey (USGS) archive are being reprocessed to generate a tiered collection of consistently geolocated and radiometrically calibrated products that are suitable for time series analyses. With the implementation of the collection management, no major updates will be made to calibration of the Landsat sensors within a collection. Only calibration parameters needed to maintain the established calibration trends without an effect on derived environmental records will be regularly updated, while all other changes will be deferred to a new collection. This first collection, Collection 1, incorporates various radiometric calibration updates to all Landsat sensors including absolute and relative gains for Landsat 8 Operational Land Imager (OLI), stray light correction for Landsat 8 Thermal Infrared Sensor (TIRS), absolute gains for Landsat 4 and 5 Thematic Mappers (TM), recalibration of Landsat 1-5 Multispectral Scanners (MSS) to ensure radiometric consistency among different formats of archived MSS data, and a transfer of Landsat 8 OLI reflectance based calibration to all previous Landsat sensors. While all OLI/TIRS, ETM+ and majority of TM data have already been reprocessed to Collection 1, a completion of MSS and remaining TM data reprocessing is expected by the end of this year. It is important to note that, although still available for download from the USGS web pages, the products generated using the Pre-Collection processing do not benefit from the latest radiometric calibration updates. In this paper, we are assessing radiometry of solar reflective bands in Landsat Collection 1 products through analysis of trends in on-board calibrator and pseudo invariant site (PICS) responses.

  8. Radiometric relations of a sugarcane crop

    International Nuclear Information System (INIS)

    Machado, E.C.; Pereira, A.R.; Camargo, M.B.P. de; Fahl, J.I.

    1985-01-01

    The radiometric relations of a sugarcane crop, cv. NA56-79, are studied during the period of maximum leaf area index. The coefficients of reflection, transmission and absorption of the incoming solar radiation were function of solar elevation and the waveband considered. The photosynthetically active radiation was always less reflected and transmitted but more absorved than the near infrared radiation. (M.A.C.) [pt

  9. Detecting payload performance based on relative radiometric characteristic: case of the optical sensors

    Science.gov (United States)

    Han, Jie; Li, Shengyang; Zhang, Tao; Qin, Bangyong

    2016-10-01

    In this paper, we propose a novel algorithm for accurately estimating the degree of radiometric non-uniformity in remote sensing images. The algorithm was tested on high-quality images and heavily striping images, and quantitative analyses were conducted to evaluate the performance for each band by measuring the radiometric non-uniformity of the images. The results demonstrated that the proposed algorithm exhibits high accuracy and stability compared with traditional algorithms. The radiometric performance of TianGong-1 short-wave infrared images was calculated using this new method, and it was highly correlated with the solar angle, pitch angle and refrigerator thermal according to the Apriori algorithm. Based on these results, we have proposed a strategy for restricting increases in striping.

  10. RADIOMETRIC CALIBRATION OF MARS HiRISE HIGH RESOLUTION IMAGERY BASED ON FPGA

    Directory of Open Access Journals (Sweden)

    Y. Hou

    2016-06-01

    Full Text Available Due to the large data amount of HiRISE imagery, traditional radiometric calibration method is not able to meet the fast processing requirements. To solve this problem, a radiometric calibration system of HiRISE imagery based on field program gate array (FPGA is designed. The montage gap between two channels caused by gray inconsistency is removed through histogram matching. The calibration system is composed of FPGA and DSP, which makes full use of the parallel processing ability of FPGA and fast computation as well as flexible control characteristic of DSP. Experimental results show that the designed system consumes less hardware resources and the real-time processing ability of radiometric calibration of HiRISE imagery is improved.

  11. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    Directory of Open Access Journals (Sweden)

    Alireza G. Kashani

    2015-11-01

    Full Text Available In addition to precise 3D coordinates, most light detection and ranging (LIDAR systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  12. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration.

    Science.gov (United States)

    Kashani, Alireza G; Olsen, Michael J; Parrish, Christopher E; Wilson, Nicholas

    2015-11-06

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record "intensity", loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of "normalization", "correction", or "calibration" techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  13. Radiometric microassay for ornithine decarboxylase

    Energy Technology Data Exchange (ETDEWEB)

    Maderdrut, J L; Oppenheim, R W [North Carolina Univ., Chapel Hill (USA). School of Medicine

    1978-01-01

    A simple method for purifying (/sup 3/H)L-ornithine and incubation conditions suitable for estimating L-ornithine decarboxylase activity are described. Routine and recycle cation exchange procedures for separating putrescine from ornithine are outlined. Blanks using the routine cation exchange method average approx. 0.04% of the radioactivity contained in the substrate; product recovery is approx. 94%. The L-ornithine decarboxylase assay is proportional to time for at least 8 h. The relationship between substrate purity and the sensitivity of the cation exchange procedures is assessed. Radiochemical purity is the critical determinant of sensitivity for recycled assays. The cation exchange method is compared with the commonly used CO/sub 2/-trapping method. The cation exchange method is more specific and approximately three orders of magnitude more sensitive than the CO/sub 2/-trapping method. L-ornithine decarboxylase activity can be measured reliably in samples of embryonic neural tissues having wet-weights of approx. 1 ..mu..g. L-ornithine decarboxylase activity in the lumbar spinal cord of the chick embryo decreases 25-30 fold from day 5 to day 18 of embryonic development. A cation exchange procedure for estimating L-lysine decarboxylase activity is also described. Failure to detect L-lysine decarboxylase activity in the chick embryo lumbar spinal cord is contrasted with the previous report of high cadaverine levels in chick embryos.

  14. GEOMETRIC AND RADIOMETRIC EVALUATION OF RASAT IMAGES

    Directory of Open Access Journals (Sweden)

    A. Cam

    2016-06-01

    Full Text Available RASAT, the second remote sensing satellite of Turkey, was designed and assembled, and also is being operated by TÜBİTAK Uzay (Space Technologies Research Institute (Ankara. RASAT images in various levels are available free-of-charge via Gezgin portal for Turkish citizens. In this paper, the images in panchromatic (7.5 m GSD and RGB (15 m GSD bands in various levels were investigated with respect to its geometric and radiometric characteristics. The first geometric analysis is the estimation of the effective GSD as less than 1 pixel for radiometrically processed level (L1R of both panchromatic and RGB images. Secondly, 2D georeferencing accuracy is estimated by various non-physical transformation models (similarity, 2D affine, polynomial, affine projection, projective, DLT and GCP based RFM reaching sub-pixel accuracy using minimum 39 and maximum 52 GCPs. The radiometric characteristics are also investigated for 8 bits, estimating SNR between 21.8-42.2, and noise 0.0-3.5 for panchromatic and MS images for L1R when the sea is masked to obtain the results for land areas. The analysis show that RASAT images satisfies requirements for various applications. The research is carried out in Zonguldak test site which is mountainous and partly covered by dense forest and urban areas.

  15. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  16. A rapid method for monitoring the hydrodeoxygenation of coal-derived naphtha

    Energy Technology Data Exchange (ETDEWEB)

    Farnand, B.A.; Coulombe, S.; Smiley, G.T.; Fairbridge, C.

    1988-01-01

    A bonded polar poly(ethylene glycol) capillary column has been used for the identification and quantification of the phenolic components in synthetic crude naphthas. This provides a rapid and routine method for the determination of phenolic oxygen content with results comparable to combustion and neutron activation methods. The method is most useful in monitoring the removal of phenolic oxygen by hydroprocessing. 11 refs., 1 fig. 1 tab.

  17. Rapid analysis method for the determination of 14C specific activity in irradiated graphite.

    Directory of Open Access Journals (Sweden)

    Vidmantas Remeikis

    Full Text Available 14C is one of the limiting radionuclides used in the categorization of radioactive graphite waste; this categorization is crucial in selecting the appropriate graphite treatment/disposal method. We propose a rapid analysis method for 14C specific activity determination in small graphite samples in the 1-100 μg range. The method applies an oxidation procedure to the sample, which extracts 14C from the different carbonaceous matrices in a controlled manner. Because this method enables fast online measurement and 14C specific activity evaluation, it can be especially useful for characterizing 14C in irradiated graphite when dismantling graphite moderator and reflector parts, or when sorting radioactive graphite waste from decommissioned nuclear power plants. The proposed rapid method is based on graphite combustion and the subsequent measurement of both CO2 and 14C, using a commercial elemental analyser and the semiconductor detector, respectively. The method was verified using the liquid scintillation counting (LSC technique. The uncertainty of this rapid method is within the acceptable range for radioactive waste characterization purposes. The 14C specific activity determination procedure proposed in this study takes approximately ten minutes, comparing favorably to the more complicated and time consuming LSC method. This method can be potentially used to radiologically characterize radioactive waste or used in biomedical applications when dealing with the specific activity determination of 14C in the sample.

  18. Rapid analysis method for the determination of 14C specific activity in irradiated graphite.

    Science.gov (United States)

    Remeikis, Vidmantas; Lagzdina, Elena; Garbaras, Andrius; Gudelis, Arūnas; Garankin, Jevgenij; Plukienė, Rita; Juodis, Laurynas; Duškesas, Grigorijus; Lingis, Danielius; Abdulajev, Vladimir; Plukis, Artūras

    2018-01-01

    14C is one of the limiting radionuclides used in the categorization of radioactive graphite waste; this categorization is crucial in selecting the appropriate graphite treatment/disposal method. We propose a rapid analysis method for 14C specific activity determination in small graphite samples in the 1-100 μg range. The method applies an oxidation procedure to the sample, which extracts 14C from the different carbonaceous matrices in a controlled manner. Because this method enables fast online measurement and 14C specific activity evaluation, it can be especially useful for characterizing 14C in irradiated graphite when dismantling graphite moderator and reflector parts, or when sorting radioactive graphite waste from decommissioned nuclear power plants. The proposed rapid method is based on graphite combustion and the subsequent measurement of both CO2 and 14C, using a commercial elemental analyser and the semiconductor detector, respectively. The method was verified using the liquid scintillation counting (LSC) technique. The uncertainty of this rapid method is within the acceptable range for radioactive waste characterization purposes. The 14C specific activity determination procedure proposed in this study takes approximately ten minutes, comparing favorably to the more complicated and time consuming LSC method. This method can be potentially used to radiologically characterize radioactive waste or used in biomedical applications when dealing with the specific activity determination of 14C in the sample.

  19. A novel method of rapidly modeling optical properties of actual photonic crystal fibres

    International Nuclear Information System (INIS)

    Li-Wen, Wang; Shu-Qin, Lou; Wei-Guo, Chen; Hong-Lei, Li

    2010-01-01

    The flexible structure of photonic crystal fibre not only offers novel optical properties but also brings some difficulties in keeping the fibre structure in the fabrication process which inevitably cause the optical properties of the resulting fibre to deviate from the designed properties. Therefore, a method of evaluating the optical properties of the actual fibre is necessary for the purpose of application. Up to now, the methods employed to measure the properties of the actual photonic crystal fibre often require long fibre samples or complex expensive equipments. To our knowledge, there are few studies of modeling an actual photonic crystal fibre and evaluating its properties rapidly. In this paper, a novel method, based on the combination model of digital image processing and the finite element method, is proposed to rapidly model the optical properties of the actual photonic crystal fibre. Two kinds of photonic crystal fibres made by Crystal Fiber A/S are modeled. It is confirmed from numerical results that the proposed method is simple, rapid and accurate for evaluating the optical properties of the actual photonic crystal fibre without requiring complex equipment. (rapid communication)

  20. Air Kerma above environmental radiometric calibration facility for field equipment

    International Nuclear Information System (INIS)

    Conti, C.C.; Sachett, I.A.; Bertelli, L.; Lopes, R.T.

    2000-01-01

    The use of gamma ray spectrometers broadened the aims of gamma ray surveys, stead of measuring only the gross radiation, as was done with the GM tubes, it is now possible to be used for uranium exploration, geological mapping as an aid to the exploration of non radioactive ores like gold and tin, radiation background measurements to identify hot spots for radiation hazard evaluation and environmental monitoring of fallout from radiological and nuclear accidents. It became necessary to carefully and precisely calibrate the field equipment to be used to get all the information from such uses. There is an environmental radiometric calibration facility for field equipment, consisting of eight radioactive concrete sources, at the Institute of Radioprotection and Dosimetry - IRD (CNEN/Brazil). These sources are cylindrical with 3 m diameter, 0.5 m thick and weigh about 7.5 tons each. The amount and type of the radioactive material, 238 U and 232 Th and 40 K ores in secular radioactive equilibrium, added to the concrete to simulate rock outcrops, varies in order to obtain different gamma fields, varying in both energy and intensity. These different radiation fields were measured with a HPGe portable detector, specifically calibrated for spectrum stripping, and the air kerma energy distribution was determined for each concrete source and compared with the total air kerma calculated from the nuclide concentration and by others radiometric methods. (author)

  1. [Experimental rationale for the parameters of a rapid method for oxidase activity determination].

    Science.gov (United States)

    Butorina, N N

    2010-01-01

    Experimental rationale is provided for the parameters of a rapid (1-2-min) test to concurrently determine the oxidase activity of all bacteria grown on the membrane filter after water filtration. Oxidase reagents that are the aqueous solutions of tetramethyl-p-phenylenediamine dihydrochloride and demethyl-p-phenylenediamine dihydrochloride have been first ascertained to exert no effect on the viability and enzymatic activity of bacteria after one-hour contact. An algorithm has been improved for the rapid oxidase activity test: the allowable time for bacteria to contact oxidase reagents and procedures for minimizing the effect on bacterial biochemical activity following the contact. An accelerated method based on lactose medium with tergitol 7 and Endo agar has been devised to determine coliform bacteria, by applying the rapid oxidase test: the time of a final response is 18-24 hours. The method has been included into GOST 52426-2005.

  2. Radiometric control of the position of blind holes axes in graphite blocks of high temperature reactors

    International Nuclear Information System (INIS)

    Boutaine, J.L.; Bujas, R.; Lemonnier, A.; Tortel, J.

    1976-01-01

    The principles of a radiometric method intended for controlling the positions of blind hole axes are given. A comparison is made between radiometry and radiography and the performances obtained using a thulium 170 source are described. The automation capabilities are discussed [fr

  3. Automatic Radiometric Normalization of Multitemporal Satellite Imagery with the Iteratively Re-weighted MAD Transformation

    DEFF Research Database (Denmark)

    Canty, Morton John; Nielsen, Allan Aasbjerg

    2008-01-01

    A recently proposed method for automatic radiometric normalization of multi- and hyper-spectral imagery based on the invariance property of the Multivariate Alteration Detection (MAD) transformation and orthogonal linear regression is extended by using an iterative re-weighting scheme involving no...

  4. A rapid method for screening arrayed plasmid cDNA library by PCR

    International Nuclear Information System (INIS)

    Hu Yingchun; Zhang Kaitai; Wu Dechang; Li Gang; Xiang Xiaoqiong

    1999-01-01

    Objective: To develop a PCR-based method for rapid and effective screening of arrayed plasmid cDNA library. Methods: The plasmid cDNA library was arrayed and screened by PCR with a particular set of primers. Results: Four positive clones were obtained through about one week. Conclusion: This method can be applied to screening not only normal cDNA clones, but also cDNA clones-containing small size fragments. This method offers significant advantages over traditional screening method in terms of sensitivity, specificity and efficiency

  5. The radiometric industries of the countries of the European Community

    International Nuclear Information System (INIS)

    Roeper, Burkhardt

    1975-01-01

    The economic development of the radiometric industries in the EEC and the USA since 1960 is studied on the basis of sales statistics. The study covers the supply and the use of radioisotopes, the application of radiometric techniques, the scope and the development of the foreign trade as well as the structure of the firms concerned. The future need for radiometric apparatus is estimated as regards radiation protection, laboratories, industry, nuclear power plants and medicine

  6. Considerations for Task Analysis Methods and Rapid E-Learning Development Techniques

    Directory of Open Access Journals (Sweden)

    Dr. Ismail Ipek

    2014-02-01

    Full Text Available The purpose of this paper is to provide basic dimensions for rapid training development in e-learning courses in education and business. Principally, it starts with defining task analysis and how to select tasks for analysis and task analysis methods for instructional design. To do this, first, learning and instructional technologies as visions of the future were discussed. Second, the importance of task analysis methods in rapid e-learning was considered, with learning technologies as asynchronous and synchronous e-learning development. Finally, rapid instructional design concepts and e-learning design strategies were defined and clarified with examples, that is, all steps for effective task analysis and rapid training development techniques based on learning and instructional design approaches were discussed, such as m-learning and other delivery systems. As a result, the concept of task analysis, rapid e-learning development strategies and the essentials of online course design were discussed, alongside learner interface design features for learners and designers.

  7. Rapid expansion method (REM) for time‐stepping in reverse time migration (RTM)

    KAUST Repository

    Pestana, Reynam C.; Stoffa, Paul L.

    2009-01-01

    an analytical approximation for the Bessel function where we assume that the time step is sufficiently small. From this derivation we find that if we consider only the first two Chebyshev polynomials terms in the rapid expansion method we can obtain the second

  8. Rapid in vivo screening method for the evaluation of new anti ...

    African Journals Online (AJOL)

    Rapid in vivo screening method for the evaluation of new anti helicobacter ... Six to eight week-old mice pre-treated (7 days) with Amoxicillin/Metronidazole (25 ... These findings were used as a mouse model of Helicobacter pylori infection to ...

  9. Simple rapid methods for freezing hybridomas in 96-well microculture plates.

    Science.gov (United States)

    Wells, D E; Price, P J

    1983-04-15

    Macroscopic hybridoma colonies were frozen and recovered in a good state of viability in 96-well microculture plates using 2 freezing procedures. These methods offer convenient and rapid means of preserving hybridomas and will permit laboratories developing monoclonal antibodies to distribute workloads to more manageable levels without discarding possibly valuable hybridomas.

  10. A critical analysis of methods for rapid and nondestructive determination of wood density in standing trees

    Science.gov (United States)

    Shan Gao; Xiping Wang; Michael C. Wiemann; Brian K. Brashaw; Robert J. Ross; Lihai Wang

    2017-01-01

    Key message Field methods for rapid determination of wood density in trees have evolved from increment borer, torsiometer, Pilodyn, and nail withdrawal into sophisticated electronic tools of resistance drilling measurement. A partial resistance drilling approach coupled with knowledge of internal tree density distribution may...

  11. A Rapid Method for Measuring Strontium-90 Activity in Crops in China

    Science.gov (United States)

    Pan, Lingjing Pan; Yu, Guobing; Wen, Deyun; Chen, Zhi; Sheng, Liusi; Liu, Chung-King; Xu, X. George

    2017-09-01

    A rapid method for measuring Sr-90 activity in crop ashes is presented. Liquid scintillation counting, combined with ion exchange columns 4`, 4"(5")-di-t-butylcyclohexane-18-crown-6, is used to determine the activity of Sr-90 in crops. The yields of chemical procedure are quantified using gravimetric analysis. The conventional method that uses ion-exchange resin with HDEHP could not completely remove all the bismuth when comparatively large lead and bismuth exist in the samples. This is overcome by the rapid method. The chemical yield of this method is about 60% and the MDA for Sr-90 is found to be 2:32 Bq/kg. The whole procedure together with using spectrum analysis to determine the activity only takes about one day, which is really a large improvement compared with the conventional method. A modified conventional method is also described here to verify the value of the rapid one. These two methods can meet di_erent needs of daily monitoring and emergency situation.

  12. A rapid radiobioassay method for strontium estimation in nuclear/radiological emergencies

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Sawant, Pramilla D.; Rao, D.D.; Pradeepkumar, K.S.

    2014-01-01

    During a nuclear/radiological emergency, workers as well as members of the public (MOP) may get internally contaminated with the radionuclides like Sr and Cs. In such situations, a truly rapid radiobioassay method is required to screen a large number of people in order to assess internal contamination and also to decide on subsequent medical intervention. The current precipitation method used at Bioassay Lab., Trombay is quite lengthy and laborious. Efforts are being made to optimize bioassay methods at Bhabha Atomic Research Centre using Solid Extraction Chromatography (SEC) technique for emergency response. The present work reports standardization of SEC technique for rapid estimation of Sr in urine samples. The method standardized using Sr spec is simpler, shorter, result in higher recoveries and reproducible results. It is most suitable for quick dose assessment of 90 Sr in bioassay samples in case of emergency

  13. Rapid HPLC-MS method for the simultaneous determination of tea catechins and folates.

    Science.gov (United States)

    Araya-Farias, Monica; Gaudreau, Alain; Rozoy, Elodie; Bazinet, Laurent

    2014-05-14

    An effective and rapid HPLC-MS method for the simultaneous separation of the eight most abundant tea catechins, gallic acid, and caffeine was developed. These compounds were rapidly separated within 9 min by a linear gradient elution using a Zorbax SB-C18 packed with sub 2 μm particles. This methodology did not require preparative and semipreparative HPLC steps. In fact, diluted tea samples can be easily analyzed using HPLC-MS as described in this study. The use of mass spectrometry detection for quantification of catechins ensured a higher specificity of the method. The percent relative standard deviation was generally lower than 4 and 7% for most of the compounds tested in tea drinks and tea extracts, respectively. Furthermore, the method provided excellent resolution for folate determination alone or in combination with catechins. To date, no HPLC method able to discriminate catechins and folates in a quick analysis has been reported in the literature.

  14. A rapid method for soil cement design : Louisiana slope value method.

    Science.gov (United States)

    1964-03-01

    The current procedure used by the Louisiana Department of Highways for laboratory design of cement stabilized soil base and subbase courses is taken from standard AASHO test methods, patterned after Portland Cement Association criteria. These methods...

  15. Rapid-Viability PCR Method for Detection of Live, Virulent Bacillus anthracis in Environmental Samples ▿

    OpenAIRE

    Létant, Sonia E.; Murphy, Gloria A.; Alfaro, Teneile M.; Avila, Julie R.; Kane, Staci R.; Raber, Ellen; Bunt, Thomas M.; Shah, Sanjiv R.

    2011-01-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real...

  16. Apparatus and method for rapid separation and detection of hydrocarbon fractions in a fluid stream

    Science.gov (United States)

    Sluder, Charles S.; Storey, John M.; Lewis, Sr., Samuel A.

    2013-01-22

    An apparatus and method for rapid fractionation of hydrocarbon phases in a sample fluid stream are disclosed. Examples of the disclosed apparatus and method include an assembly of elements in fluid communication with one another including one or more valves and at least one sorbent chamber for removing certain classifications of hydrocarbons and detecting the remaining fractions using a detector. The respective ratios of hydrocarbons are determined by comparison with a non separated fluid stream.

  17. Interconnection blocks: a method for providing reusable, rapid, multiple, aligned and planar microfluidic interconnections

    International Nuclear Information System (INIS)

    Sabourin, D; Snakenborg, D; Dufva, M

    2009-01-01

    In this paper a method is presented for creating 'interconnection blocks' that are re-usable and provide multiple, aligned and planar microfluidic interconnections. Interconnection blocks made from polydimethylsiloxane allow rapid testing of microfluidic chips and unobstructed microfluidic observation. The interconnection block method is scalable, flexible and supports high interconnection density. The average pressure limit of the interconnection block was near 5.5 bar and all individual results were well above the 2 bar threshold considered applicable to most microfluidic applications

  18. Rapid qualitative research methods during complex health emergencies: A systematic review of the literature.

    Science.gov (United States)

    Johnson, Ginger A; Vindrola-Padros, Cecilia

    2017-09-01

    The 2013-2016 Ebola outbreak in West Africa highlighted both the successes and limitations of social science contributions to emergency response operations. An important limitation was the rapid and effective communication of study findings. A systematic review was carried out to explore how rapid qualitative methods have been used during global heath emergencies to understand which methods are commonly used, how they are applied, and the difficulties faced by social science researchers in the field. We also asses their value and benefit for health emergencies. The review findings are used to propose recommendations for qualitative research in this context. Peer-reviewed articles and grey literature were identified through six online databases. An initial search was carried out in July 2016 and updated in February 2017. The PRISMA checklist was used to guide the reporting of methods and findings. The articles were assessed for quality using the MMAT and AACODS checklist. From an initial search yielding 1444 articles, 22 articles met the criteria for inclusion. Thirteen of the articles were qualitative studies and nine used a mixed-methods design. The purpose of the rapid studies included: the identification of causes of the outbreak, and assessment of infrastructure, control strategies, health needs and health facility use. The studies varied in duration (from 4 days to 1 month). The main limitations identified by the authors were: the low quality of the collected data, small sample sizes, and little time for cross-checking facts with other data sources to reduce bias. Rapid qualitative methods were seen as beneficial in highlighting context-specific issues that need to be addressed locally, population-level behaviors influencing health service use, and organizational challenges in response planning and implementation. Recommendations for carrying out rapid qualitative research in this context included the early designation of community leaders as a point of

  19. Rapid methods for the extraction and archiving of molecular grade fungal genomic DNA.

    Science.gov (United States)

    Borman, Andrew M; Palmer, Michael; Johnson, Elizabeth M

    2013-01-01

    The rapid and inexpensive extraction of fungal genomic DNA that is of sufficient quality for molecular approaches is central to the molecular identification, epidemiological analysis, taxonomy, and strain typing of pathogenic fungi. Although many commercially available and in-house extraction procedures do eliminate the majority of contaminants that commonly inhibit molecular approaches, the inherent difficulties in breaking fungal cell walls lead to protocols that are labor intensive and that routinely take several hours to complete. Here we describe several methods that we have developed in our laboratory that allow the extremely rapid and inexpensive preparation of fungal genomic DNA.

  20. Application of a rapid screening method to detect irradiated meat in Brazil

    International Nuclear Information System (INIS)

    Villavicencio, A.L.C.H.; Mancini-Filho, J.; Delincee, H.

    2000-01-01

    Based on the enormous potential for food irradiation in Brazil, and to ensure free consumer choice, there is a need to find a convenient and rapid method for detection of irradiated food. Since treatment with ionising radiation causes DNA fragmentation, the analysis of DNA damage might be promising. In this paper, the DNA Comet Assay was used to identify exotic meat (boar, jacare and capybara), irradiated with 60 Co gamma rays. The applied radiation doses were 0, 1.5, 3.0 and 4.5 kGy. Analysis of the DNA migration enabled a rapid identification of the radiation treatment

  1. Radiometric survey in sampling areas of Itataia mine ore and radiometric monitoring in Itataia project sites

    International Nuclear Information System (INIS)

    1982-07-01

    This radiometric survey was done by CDTN, in Itataia sites, on July/82 and it aimed fundamentally to evaluate local radiological conditions, as for aspect of occupational radiation protection. Besides of results obtained, this report has informations of general aspects that ought to serve as subsidies for elaboration of radiological protection program of local. (author) [pt

  2. Application of a rapid screening method to detect irradiated meat in Brazil

    International Nuclear Information System (INIS)

    Villavicencio, A.L.C.H.; Delincee, H.

    1998-01-01

    Complete text of publication follows. Based on the enormous potential for food irradiation in Brazil, and to ensure free consumer choice, there is a need to find a convenient and rapid method for detection of irradiated food. Since treatment with ionizing radiation causes DNA fragmentation, the analysis of DNA damage might be promising. In fact, DNA fragmentation measured in single cells by agarose gel electrophoresis - DNA Comet Assay - has shown to offer great potential as a rapid tool to detect whether a wide variety of foodstuffs has been radiation processed. However, more work is needed to exploit the full potential of this promising technique. In this paper, the DNA Comet Assay was used to identify exotic meat (boar, jacare and capybara), irradiated with 60 Co gamma-rays. The applied radiation doses were 0, 1.5, 3.0 and 4.5 kGy. Analysis of the DNA migration enable a rapid identification of the radiation treatment

  3. Effectiveness of Rapid Cooling as a Method of Euthanasia for Young Zebrafish (Danio rerio).

    Science.gov (United States)

    Wallace, Chelsea K; Bright, Lauren A; Marx, James O; Andersen, Robert P; Mullins, Mary C; Carty, Anthony J

    2018-01-01

    Despite increased use of zebrafish (Danio rerio) in biomedical research, consistent information regarding appropriate euthanasia methods, particularly for embryos, is sparse. Current literature indicates that rapid cooling is an effective method of euthanasia for adult zebrafish, yet consistent guidelines regarding zebrafish younger than 6 mo are unavailable. This study was performed to distinguish the age at which rapid cooling is an effective method of euthanasia for zebrafish and the exposure times necessary to reliably euthanize zebrafish using this method. Zebrafish at 3, 4, 7, 14, 16, 19, 21, 28, 60, and 90 d postfertilization (dpf) were placed into an ice water bath for 5, 10, 30, 45, or 60 min (n = 12 to 40 per group). In addition, zebrafish were placed in ice water for 12 h (age ≤14 dpf) or 30 s (age ≥14 dpf). After rapid cooling, fish were transferred to a recovery tank and the number of fish alive at 1, 4, and 12-24 h after removal from ice water was documented. Euthanasia was defined as a failure when evidence of recovery was observed at any point after removal from ice water. Results showed that younger fish required prolonged exposure to rapid cooling for effective euthanasia, with the required exposure time decreasing as fish age. Although younger fish required long exposure times, animals became immobilized immediately upon exposure to the cold water, and behavioral indicators of pain or distress rarely occurred. We conclude that zebrafish 14 dpf and younger require as long as 12 h, those 16 to 28 dpf of age require 5 min, and those older than 28 dpf require 30 s minimal exposure to rapid cooling for reliable euthanasia.

  4. A rapid reliability estimation method for directed acyclic lifeline networks with statistically dependent components

    International Nuclear Information System (INIS)

    Kang, Won-Hee; Kliese, Alyce

    2014-01-01

    Lifeline networks, such as transportation, water supply, sewers, telecommunications, and electrical and gas networks, are essential elements for the economic and societal functions of urban areas, but their components are highly susceptible to natural or man-made hazards. In this context, it is essential to provide effective pre-disaster hazard mitigation strategies and prompt post-disaster risk management efforts based on rapid system reliability assessment. This paper proposes a rapid reliability estimation method for node-pair connectivity analysis of lifeline networks especially when the network components are statistically correlated. Recursive procedures are proposed to compound all network nodes until they become a single super node representing the connectivity between the origin and destination nodes. The proposed method is applied to numerical network examples and benchmark interconnected power and water networks in Memphis, Shelby County. The connectivity analysis results show the proposed method's reasonable accuracy and remarkable efficiency as compared to the Monte Carlo simulations

  5. Use of Radiometric Survey Data for Environmental Study: The Case of Northern Sumatera

    International Nuclear Information System (INIS)

    Tjokrokardono, S; Ramadanus; Sustarman, H

    1998-01-01

    The convertion of old radiometric data obtained from former uranium exploration activities in northem sumatra into radiation exposure has been evaluated. The objective of the study is to find an alternative way for cheaper and faster compilation of radiation exposure database for environmental study purposes. The old radiometric data measure from the outcrops has been plotted 1;250.000, 1;100.000, and 1;50.000 map scales. The data are translated into 1;1000.000 map scale before they are converted into 1;1000.000 radiation exposure rate map using a graphic method. The radiation exposure rate in northem sumatera falls between 25 R/hour to 40 R/hour. The benefit offered using this method is that it provides a cheaper and faster production of radiation exposure rate map from old radiometric map. However, the problems arising from such a production is that the radiometric data provide unhomogeneous data distributions and densities among the area. As a conclusion it is recommended to recollect some of the data at designated area using well calibrated SPP2NF and gamma ray spectrometer instruments

  6. Visual and colorimetric methods for rapid determination of total tannins in vegetable raw materials

    Directory of Open Access Journals (Sweden)

    S. P. Kalinkina

    2016-01-01

    Full Text Available The article is dedicated to the development of rapid colorimetric method for determining the amount of tannins in aqueous extracts of vegetable raw materials. The sorption-based colorimetric test is determining sorption tannins polyurethane foam, impregnated of FeCl3, receiving on its surface painted in black and green color of the reaction products and the determination of their in sorbent matrix. Selectivity is achieved by determining the tannins specific interaction of polyphenols with iron ions (III. The conditions of sorption-colorimetric method: the concentration of ferric chloride (III, impregnated in the polyurethane foam; sorbent mass in the analytical cartridge; degree of loading his agent; the contact time of the phases. color scales have been developed for the visual determination of the amount of tannins in terms of gallic acid. Spend a digitized image obtained scales using computer program “Sorbfil TLC”, excluding a subjective assessment of the intensity of the color scale of the test. The results obtained determine the amount of tannins in aqueous extracts of vegetable raw rapid method using tablets and analytical cartridges. The results of the test determination of tannins with visual and densitometric analytical signal registration are compared to known methods. Spend a metrological evaluation of the results of determining the amount of tannins sorption rapid colorimetric methods. Time visual and densitometric rapid determination of tannins, taking into account the sample preparation is 25–30 minutes, the relative error does not exceed 28 %. The developed test methods for quantifying the content of tannins allow to exclude the use of sophisticated analytical equipment, carry out the analysis in non-laboratory conditions do not require highly skilled personnel.

  7. 3D virtual human rapid modeling method based on top-down modeling mechanism

    Directory of Open Access Journals (Sweden)

    LI Taotao

    2017-01-01

    Full Text Available Aiming to satisfy the vast custom-made character demand of 3D virtual human and the rapid modeling in the field of 3D virtual reality, a new virtual human top-down rapid modeling method is put for-ward in this paper based on the systematic analysis of the current situation and shortage of the virtual hu-man modeling technology. After the top-level realization of virtual human hierarchical structure frame de-sign, modular expression of the virtual human and parameter design for each module is achieved gradu-al-level downwards. While the relationship of connectors and mapping restraints among different modules is established, the definition of the size and texture parameter is also completed. Standardized process is meanwhile produced to support and adapt the virtual human top-down rapid modeling practice operation. Finally, the modeling application, which takes a Chinese captain character as an example, is carried out to validate the virtual human rapid modeling method based on top-down modeling mechanism. The result demonstrates high modelling efficiency and provides one new concept for 3D virtual human geometric mod-eling and texture modeling.

  8. Rapid determination of tannins in tanning baths by adaptation of BSA method.

    Science.gov (United States)

    Molinari, R; Buonomenna, M G; Cassano, A; Drioli, E

    2001-01-01

    A rapid and reproducible method for the determination of tannins in vegetable tanning baths is proposed as a modification of the BSA method for grain tannins existing in literature. The protein BSA was used instead of leather powder employed in the Filter Method, which is adopted in Italy and various others countries of Central Europe. In this rapid method the tannin contents is determined by means a spectrophotometric reading and not by means a gravimetric analysis of the Filter Method. The BSA method, which belongs to mixed methods (which use both precipitation and complexation of tannins), consists of selective precipitation of tannin from a solution containing also non tannins by BSA, the dissolution of precipitate and the quantification of free tannin amount by its complexation with Fe(III) in hydrochloric solutions. The absorbance values, read at 522 nm, have been expressed in terms of tannic acid concentration by using a calibration curve made with standard solutions of tannic acid; these have been correlated with the results obtained by using the Filter Method.

  9. Application of Rapid Prototyping Methods to High-Speed Wind Tunnel Testing

    Science.gov (United States)

    Springer, A. M.

    1998-01-01

    This study was undertaken in MSFC's 14-Inch Trisonic Wind Tunnel to determine if rapid prototyping methods could be used in the design and manufacturing of high speed wind tunnel models in direct testing applications, and if these methods would reduce model design/fabrication time and cost while providing models of high enough fidelity to provide adequate aerodynamic data, and of sufficient strength to survive the test environment. Rapid prototyping methods utilized to construct wind tunnel models in a wing-body-tail configuration were: fused deposition method using both ABS plastic and PEEK as building materials, stereolithography using the photopolymer SL-5170, selective laser sintering using glass reinforced nylon, and laminated object manufacturing using plastic reinforced with glass and 'paper'. This study revealed good agreement between the SLA model, the metal model with an FDM-ABS nose, an SLA nose, and the metal model for most operating conditions, while the FDM-ABS data diverged at higher loading conditions. Data from the initial SLS model showed poor agreement due to problems in post-processing, resulting in a different configuration. A second SLS model was tested and showed relatively good agreement. It can be concluded that rapid prototyping models show promise in preliminary aerodynamic development studies at subsonic, transonic, and supersonic speeds.

  10. Tasmanian tin and tungsten granites - their radiometric characteristics

    International Nuclear Information System (INIS)

    Yeates, A.N.

    1982-01-01

    A radiometric survey of Tasmanian granites has shown, with one exception, that tin and tungsten-bearing granites have high radioactivity, largely owing to increased uranium. Many have a high uranium/thorium ratio as well. Radiometric measurements can also delineate different granite types within composite bodies

  11. New age radiometric ore sorting - the elegant solution

    International Nuclear Information System (INIS)

    Gordon, H.P.; Heuer, T.

    2000-01-01

    Radiometric ore sorting technology and application are described in two parts. Part I reviews the history of radiometric sorting in the minerals industry and describes the latest developments in radiometric sorting technology. Part II describes the history, feasibility study and approach used in the application of the new technology at Rossing Uranium Limited. There has been little progress in the field of radiometric sorting since the late 1970s. This has changed with the development of a high capacity radiometric sorter designed to operate on low-grade ore in the +75mm / -300mm size fraction. This has been designed specifically for an application at Rossing. Rossing has a long history in radiometric sorting dating back to 1968 when initial tests were conducted on the Rossing prospect. Past feasibility studies concluded that radiometric sorting would not conclusively reduce the unit cost of production unless sorting was used to increase production levels. The current feasibility study shows that the application of new radiometric sorter technology makes sorting viable without increasing production, and significantly more attractive with increased production. A pilot approach to confirm sorter performance is described. (author)

  12. Collaborative validation of a rapid method for efficient virus concentration in bottled water

    DEFF Research Database (Denmark)

    Schultz, Anna Charlotte; Perelle, Sylvie; Di Pasquale, Simona

    2011-01-01

    . Three newly developed methods, A, B and C, for virus concentration in bottled water were compared against the reference method D: (A) Convective Interaction Media (CIM) monolithic chromatography; filtration of viruses followed by (B) direct lysis of viruses on membrane; (C) concentration of viruses......Enteric viruses, including norovirus (NoV) and hepatitis A virus (HAV), have emerged as a major cause of waterborne outbreaks worldwide. Due to their low infectious doses and low concentrations in water samples, an efficient and rapid virus concentration method is required for routine control...... by ultracentrifugation; and (D) concentration of viruses by ultrafiltration, for each methods' (A, B and C) efficacy to recover 10-fold dilutions of HAV and feline calicivirus (FCV) spiked in bottles of 1.5L of mineral water. Within the tested characteristics, all the new methods showed better performance than method D...

  13. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy

    Science.gov (United States)

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818

  14. Solvent extraction method for rapid separation of strontium-90 in milk and food samples

    International Nuclear Information System (INIS)

    Hingorani, S.B.; Sathe, A.P.

    1991-01-01

    A solvent extraction method, using tributyl phosphate, for rapid separation of strontium-90 in milk and other food samples has been presented in this report in view of large number of samples recieved after Chernobyl accident for checking radioactive contamination. The earlier nitration method in use for the determination of 90 Sr through its daughter 90 Y takes over two weeks for analysis of a sample. While by this extraction method it takes only 4 to 5 hours for sample analysis. Complete estimation including initial counting can be done in a single day. The chemical recovery varies between 80-90% compared to nitration method which is 65-80%. The purity of the method has been established by following the decay of yttrium-90 separated. Some of the results obtained by adopting this chemical method for food analysis are included. The method is, thus, found to be rapid and convenient for accurate estimation of strontium-90 in milk and food samples. (author). 2 tabs., 1 fig

  15. New methods for rapid data acquisition of contaminated land cover after NPP accident

    International Nuclear Information System (INIS)

    Hulka, J.; Cespirova, I.

    2008-01-01

    Aim of the research project is the analysis of the modem and rapid reliable data acquisition methods for agricultural countermeasures, feed-stuff restrictions and clean-up of large contaminated areas after NPP accident. Acquiring agricultural reliable data especially based on satellite technology and analysis of landscape contamination (based on computer code vs. in situ measurements, airborne and/or terrestrial mapping of contamination) are discussed. (authors)

  16. A rapid method for establishment of a reverse genetics system for canine parvovirus.

    Science.gov (United States)

    Yu, Yongle; Su, Jun; Wang, Jigui; Xi, Ji; Mao, Yaping; Hou, Qiang; Zhang, Xiaomei; Liu, Weiquan

    2017-12-01

    Canine parvovirus (CPV) is an important and highly prevalent pathogen of dogs that causes acute hemorrhagic enteritis disease. Here, we describe a rapid method for the construction and characterization of a full-length infectious clone (rCPV) of CPV. Feline kidney (F81) cells were transfected with rCPV incorporating an engineered EcoR I site that served as a genetic marker. The rescued virus was indistinguishable from that of wild-type virus in its biological properties.

  17. New methods for rapid data acquisition of contaminated land cover after NPP accident

    International Nuclear Information System (INIS)

    Hulka, J.; Cespirova, I.

    2009-01-01

    Aim of the research project is the analysis of the modem and rapid reliable data acquisition methods for agricultural countermeasures, feed-stuff restrictions and clean-up of large contaminated areas after NPP accident. Acquiring agricultural reliable data especially based on satellite technology and analysis of landscape contamination (based on computer code vs. in situ measurements, airborne and/or terrestrial mapping of contamination) are discussed. (authors)

  18. A simple, rapid and inexpensive screening method for the identification of Pythium insidiosum.

    Science.gov (United States)

    Tondolo, Juliana Simoni Moraes; Loreto, Erico Silva; Denardi, Laura Bedin; Mario, Débora Alves Nunes; Alves, Sydney Hartz; Santurio, Janio Morais

    2013-04-01

    Growth of Pythium insidiosum mycelia around minocycline disks (30μg) did not occur within 7days of incubation at 35°C when the isolates were grown on Sabouraud, corn meal, Muller-Hinton or RPMI agar. This technique offers a simple and rapid method for the differentiation of P. insidiosum from true filamentous fungi. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. A rapid method for the determination of some antihypertensive and antipyretic drugs by thermometric titrimetry.

    Science.gov (United States)

    Abbasi, U M; Chand, F; Bhanger, M I; Memon, S A

    1986-02-01

    A simple and rapid method is described for the direct thermometric determination of milligram amounts of methyl dopa, propranolol hydrochloride, 1-phenyl-3-methylpyrazolone (MPP) and 2,3-dimethyl-1-phenylpyrazol-5-one (phenazone) in the presence of excipients. The compounds are reacted with N'-bromosuccinimide and the heat of reaction is used to determine the end-point of the titration. The time required is approximately 2 min, and the accuracy is analytically acceptable.

  20. Determination of degree of compacting and of moisture content by radiometric probes

    International Nuclear Information System (INIS)

    Martinec, J.; Paul, P.

    1977-01-01

    A survey is given of radiometric probes used for measuring bulk density and moisture content. Surface probes are used in depths of up to 20 cm with an accuracy of 10%, drive-in probes are used to depths of up to 50 cm with a 4% error, depth probes are used for measuring in depths of 30 to 50 cm with an accuracy of roughly 5% and bulk density in depths of 10 to 150 cm may be measured with an accuracy of 2% using a lysimeter. Changes in the bulk density and soil moisture of the subsoil of an airport runway were studied radiometrically in dependence on time and depth. The dependence is represented graphically. The results of radiometric measurements were compared with the conventional method using a lysimeter probe; the comparison showed that the results were lower by about 7% for the moisture content and higher by about 8% for the bulk density. Radiometric measurements for determining bulk density and soil moisture are advantageous in that they allow the measurement of a great number of sites without any major disturbance of the measured material and results are available immediately on measurement. The economic effect is significant in a large number of measurements carried out on a surface having the same chemical composition and similar grain size which does not necessitate calibration of the instruments to be made more than once a week. The NZK-201 probe by Tesla does not provide sufficiently accurate information on the moisture and density of the earths probed

  1. Effects of agrochemicals, ultra violet stabilisers and solar radiation on the radiometric properties of greenhouse films

    Directory of Open Access Journals (Sweden)

    Giuliano Vox

    2013-10-01

    Full Text Available Agrochemicals, based on iron, sulphur and chlorine, generate by products that lead to a degradation of greenhouse films together with a decrease in their mechanical and physical properties. The degradation due to agrochemicals depends on their active principles, method and frequency of application, and greenhouse ventilation. The aim of the research was to evaluate how agrochemical contamination and solar radiation influence the radiometric properties of ethylene-vinyl acetate copolymer greenhouse films by means of laboratory and field tests. The films, manufactured on purpose with the addition of different light stabiliser systems, were exposed to natural outdoor weathering at the experimental farm of the University of Bari (Italy; 41° 05’ N in the period from 2006 to 2008. Each film was tested for two low tunnels: one low tunnel was sprayed from inside with the agrochemicals containing iron, chlorine and sulphur while the other one was not sprayed and served as control. Radiometric laboratory tests were carried out on the new films and on samples taken at the end of the trials. The experimental tests showed that both the natural weathering together with the agrochemicals did not modify significantly the radiometric properties of the films in the solar and in the photosynthetically active radiation wavelength range. Within six months of experimental field tests the variations in these radiometric characteristics were at most 10%. Significant variations, up to 70% of the initial value, were recorded for the stabilised films in the long-wave infrared radiation wavelength range.

  2. A novel sample preparation method using rapid nonheated saponification method for the determination of cholesterol in emulsified foods.

    Science.gov (United States)

    Jeong, In-Seek; Kwak, Byung-Man; Ahn, Jang-Hyuk; Leem, Donggil; Yoon, Taehyung; Yoon, Changyong; Jeong, Jayoung; Park, Jung-Min; Kim, Jin-Man

    2012-10-01

    In this study, nonheated saponification was employed as a novel, rapid, and easy sample preparation method for the determination of cholesterol in emulsified foods. Cholesterol content was analyzed using gas chromatography with a flame ionization detector (GC-FID). The cholesterol extraction method was optimized for maximum recovery from baby food and infant formula. Under these conditions, the optimum extraction solvent was 10 mL ethyl ether per 1 to 2 g sample, and the saponification solution was 0.2 mL KOH in methanol. The cholesterol content in the products was determined to be within the certified range of certified reference materials (CRMs), NIST SRM 1544 and SRM 1849. The results of the recovery test performed using spiked materials were in the range of 98.24% to 99.45% with an relative standard devitation (RSD) between 0.83% and 1.61%. This method could be used to reduce sample pretreatment time and is expected to provide an accurate determination of cholesterol in emulsified food matrices such as infant formula and baby food. A novel, rapid, and easy sample preparation method using nonheated saponification was developed for cholesterol detection in emulsified foods. Recovery tests of CRMs were satisfactory, and the recoveries of spiked materials were accurate and precise. This method was effective and decreased the time required for analysis by 5-fold compared to the official method. © 2012 Institute of Food Technologists®

  3. Rapid column extraction method for actinides and strontium in fish and other animal tissue samples

    International Nuclear Information System (INIS)

    Maxwell III, S.L.; Faison, D.M.

    2008-01-01

    The analysis of actinides and radiostrontium in animal tissue samples is very important for environmental monitoring. There is a need to measure actinide isotopes and strontium with very low detection limits in animal tissue samples, including fish, deer, hogs, beef and shellfish. A new, rapid separation method has been developed that allows the measurement of plutonium, neptunium, uranium, americium, curium and strontium isotopes in large animal tissue samples (100-200 g) with high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin R , TRU Resin R and DGA Resin R cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), neptunium (Np), uranium (U), americium (Am), and curium (Cm) using a single multi-stage column combined with alphaspectrometry. Strontium is collected on Sr Resin R from Eichrom Technologies (Darien, IL, USA). After acid digestion and furnace heating of the animal tissue samples, the actinides and 89/90 Sr are separated using column extraction chromatography. This method has been shown to be effective over a wide range of animal tissue matrices. Vacuum box cartridge technology with rapid flow rates is used to minimize sample preparation time. (author)

  4. GSMA: Gene Set Matrix Analysis, An Automated Method for Rapid Hypothesis Testing of Gene Expression Data

    Directory of Open Access Journals (Sweden)

    Chris Cheadle

    2007-01-01

    Full Text Available Background: Microarray technology has become highly valuable for identifying complex global changes in gene expression patterns. The assignment of functional information to these complex patterns remains a challenging task in effectively interpreting data and correlating results from across experiments, projects and laboratories. Methods which allow the rapid and robust evaluation of multiple functional hypotheses increase the power of individual researchers to data mine gene expression data more efficiently.Results: We have developed (gene set matrix analysis GSMA as a useful method for the rapid testing of group-wise up- or downregulation of gene expression simultaneously for multiple lists of genes (gene sets against entire distributions of gene expression changes (datasets for single or multiple experiments. The utility of GSMA lies in its flexibility to rapidly poll gene sets related by known biological function or as designated solely by the end-user against large numbers of datasets simultaneously.Conclusions: GSMA provides a simple and straightforward method for hypothesis testing in which genes are tested by groups across multiple datasets for patterns of expression enrichment.

  5. A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

    Science.gov (United States)

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-10-02

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4min, and the separation was observed in 25s. The limit of detection (LOD) was 4.0nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification. Published by Elsevier B.V.

  6. Application of pulse spectro- zonal luminescent method for the rapid method of material analysis

    International Nuclear Information System (INIS)

    Lisitsin, V.M.; Oleshko, V.I.; Yakovlev, A.N.

    2004-01-01

    Full text: The scope of luminescent methods of the analysis covers enough a big around of substances as the luminescence can be excited in overwhelming majority of nonmetals. Analytical opportunities of luminescent methods can be essentially expanded by use of pulse excitation and registration of spectra of a luminescence with the time resolved methods. The most perspective method is to use pulses of high-current electron beams with the nanosecond duration for excitation from the following reasons: excitation is carried out ionizing, deeply enough by a penetrating radiation; the pulse of radiation has high capacity, up to 10 8 W, but energy no more than 1 J; the pulse of radiation has the nanosecond duration. Electrons with energy in 300-400 keV will penetrate on depth into some tenth shares of mm, i.e. they create volumetric excitation of a sample. Therefore the luminescence raised by an electronic beam has the information about volumetric properties of substance. High density of excitation allow to find out and study the centers (defects) having a small yield of a luminescence, to analyze the weakly luminescent objects. Occurrence of the new effects is possible useful to analyze of materials. There is an opportunity of reception of the information from change of spectral structure of a luminescence during the time after the ending of a pulse of excitation and kinetic characteristics of attenuation of luminescence. The matter is the energy of radiation is absorbed mainly by a matrix, then electronic excitations one is transferred the centers of a luminescence (defects) of a lattice. Therefore during the time after creation electronic excitations the spectrum of a luminescence can repeatedly change, transferring the information on the centers (defects) which are the most effective radiators at present time. Hence, the study of change of spectra of radiation during the time allows providing an additional way of discrimination of the information on the centers of a

  7. Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol.2

    International Nuclear Information System (INIS)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines. In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios

  8. ANALYSIS OF THE RADIOMETRIC RESPONSE OF ORANGE TREE CROWN IN HYPERSPECTRAL UAV IMAGES

    Directory of Open Access Journals (Sweden)

    N. N. Imai

    2017-10-01

    Full Text Available High spatial resolution remote sensing images acquired by drones are highly relevant data source in many applications. However, strong variations of radiometric values are difficult to correct in hyperspectral images. Honkavaara et al. (2013 presented a radiometric block adjustment method in which hyperspectral images taken from remotely piloted aerial systems – RPAS were processed both geometrically and radiometrically to produce a georeferenced mosaic in which the standard Reflectance Factor for the nadir is represented. The plants crowns in permanent cultivation show complex variations since the density of shadows and the irradiance of the surface vary due to the geometry of illumination and the geometry of the arrangement of branches and leaves. An evaluation of the radiometric quality of the mosaic of an orange plantation produced using images captured by a hyperspectral imager based on a tunable Fabry-Pérot interferometer and applying the radiometric block adjustment method, was performed. A high-resolution UAV based hyperspectral survey was carried out in an orange-producing farm located in Santa Cruz do Rio Pardo, state of São Paulo, Brazil. A set of 25 narrow spectral bands with 2.5 cm of GSD images were acquired. Trend analysis was applied to the values of a sample of transects extracted from plants appearing in the mosaic. The results of these trend analysis on the pixels distributed along transects on orange tree crown showed the reflectance factor presented a slightly trend, but the coefficients of the polynomials are very small, so the quality of mosaic is good enough for many applications.

  9. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    International Nuclear Information System (INIS)

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B.

    1990-01-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis

  10. Three rapid methods for determination 90Sr in milk samples using liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Abbasisiara, F.; Attarilar, N.; Afshar, N.

    2006-01-01

    Strontium radionuclide 90 Sr is one of the main long-lived components of the radioactive fallout which occurred as a result of previous atmospheric nuclear tests and also nuclear accidents such as Chernobyl accident. Due to chemical and biochemical similarities between strontium and calcium, more than 99% of strontium is efficiently incorporated into bone tissue and teeth and Characterized by along physical and biological half-life, it may cause damage to bone marrow. Since determination of this radionuclide often is a time consuming process, rapid determination methods specially in emergency situations is always desirable. In this work, three rapid methods for determination of this radionuclide in milk samples will be evaluated. All of the methods include two major steps: 1- strontium separation from fats and proteins which can be performed by drying (in case of the fresh milk samples), ashing and leaching by nitric acids or by using exchange or chelating resins which have strong affinity for alkaline earth cations such as Dowex 50W-X8. And 2- Separation of Sr-90 or its daughter product, Y-90. In two methods separation of 90 Sr is performed by extraction of the daughter nuclide, 90 Y, by aid of organic extracting agent, Tributylphosphate or T.B.P., and then Cherenkov counting of the Y-90 extracted. The third method is based on separation of this radionuclide using Crown Ether or Sr -Spec resin. The detailed radiochemical procedures and evaluation of each method advantages or disadvantages will explained in full text paper. (authors)

  11. A Microfluidic Channel Method for Rapid Drug-Susceptibility Testing of Pseudomonas aeruginosa.

    Directory of Open Access Journals (Sweden)

    Yoshimi Matsumoto

    Full Text Available The recent global increase in the prevalence of antibiotic-resistant bacteria and lack of development of new therapeutic agents emphasize the importance of selecting appropriate antimicrobials for the treatment of infections. However, to date, the development of completely accelerated drug susceptibility testing methods has not been achieved despite the availability of a rapid identification method. We proposed an innovative rapid method for drug susceptibility testing for Pseudomonas aeruginosa that provides results within 3 h. The drug susceptibility testing microfluidic (DSTM device was prepared using soft lithography. It consisted of five sets of four microfluidic channels sharing one inlet slot, and the four channels are gathered in a small area, permitting simultaneous microscopic observation. Antimicrobials were pre-introduced into each channel and dried before use. Bacterial suspensions in cation-adjusted Mueller-Hinton broth were introduced from the inlet slot and incubated for 3 h. Susceptibilities were microscopically evaluated on the basis of differences in cell numbers and shapes between drug-treated and control cells, using dedicated software. The results of 101 clinically isolated strains of P. aeruginosa obtained using the DSTM method strongly correlated with results obtained using the ordinary microbroth dilution method. Ciprofloxacin, meropenem, ceftazidime, and piperacillin caused elongation in susceptible cells, while meropenem also induced spheroplast and bulge formation. Morphological observation could alternatively be used to determine the susceptibility of P. aeruginosa to these drugs, although amikacin had little effect on cell shape. The rapid determination of bacterial drug susceptibility using the DSTM method could also be applicable to other pathogenic species, and it could easily be introduced into clinical laboratories without the need for expensive instrumentation.

  12. Identification of new biomarker of radiation exposure for establishing rapid, simplified biodosimetric method

    International Nuclear Information System (INIS)

    Iizuka, Daisuke; Kawai, Hidehiko; Kamiya, Kenji; Suzuki, Fumio; Izumi, Shunsuke

    2014-01-01

    Until now, counting chromosome aberration is the most accurate method for evaluating radiation doses. However, this method is time consuming and requires skills for evaluating chromosome aberrations. It could be difficult to apply this method to majority of people who are expected to be exposed to ionizing radiation. In this viewpoint, establishment of rapid, simplified biodosimetric methods for triage will be anticipated. Due to the development of mass spectrometry method and the identification of new molecules such as microRNA (miRNA), it is conceivable that new molecular biomarker of radiation exposure using some newly developed mass spectrometry. In this review article, the part of our results including the changes of protein (including the changes of glycosylation), peptide, metabolite, miRNA after radiation exposure will be shown. (author)

  13. Rapid Determination of Isomeric Benzoylpaeoniflorin and Benzoylalbiflorin in Rat Plasma by LC-MS/MS Method

    Directory of Open Access Journals (Sweden)

    Chuanqi Zhou

    2017-01-01

    Full Text Available Benzoylpaeoniflorin (BP is a potential therapeutic agent against oxidative stress related Alzheimer’s disease. In this study, a more rapid, selective, and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS method was developed to determine BP in rat plasma distinguishing with a monoterpene isomer, benzoylalbiflorin (BA. The method showed a linear response from 1 to 1000 ng/mL (r>0.9950. The precision of the interday and intraday ranged from 2.03 to 12.48% and the accuracy values ranged from −8.00 to 10.33%. Each running of the method could be finished in 4 minutes. The LC-MS/MS method was validated for specificity, linearity, precision, accuracy, recovery, and stability and was found to be acceptable for bioanalytical application. Finally, this fully validated method was successfully applied to a pharmacokinetic study in rats following oral administration.

  14. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  15. Adjustment of a rapid method for quantification of Fusarium spp. spore suspensions in plant pathology.

    Science.gov (United States)

    Caligiore-Gei, Pablo F; Valdez, Jorge G

    2015-01-01

    The use of a Neubauer chamber is a broadly employed method when cell suspensions need to be quantified. However, this technique may take a long time and needs trained personnel. Spectrophotometry has proved to be a rapid, simple and accurate method to estimate the concentration of spore suspensions of isolates of the genus Fusarium. In this work we present a linear formula to relate absorbance measurements at 530nm with the number of microconidia/ml in a suspension. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. A simple and rapid method of purification of impure plutonium oxide

    International Nuclear Information System (INIS)

    Michael, K.M.; Rakshe, P.R.; Dharmpurikar, G.R.; Thite, B.S.; Lokhande, Manisha; Sinalkar, Nitin; Dakshinamoorthy, A.; Munshi, S.K.; Dey, P.K.

    2007-01-01

    Impure plutonium oxides are conventionally purified by dissolution in HNO 3 in presence of HF followed by ion exchange separation and oxalate precipitation. The method is tedious and use of HF enhances corrosion of the plant equipment's. A simple and rapid method has been developed for the purification of the oxide by leaching with various reagents like DM water, NaOH and oxalic acid. A combination of DM water followed by hot leaching with 0.4 M oxalic acid could bring down the impurity levels in the oxide to the desired level required for fuel fabrication. (author)

  17. Rapid method for protein quantitation by Bradford assay after elimination of the interference of polysorbate 80.

    Science.gov (United States)

    Cheng, Yongfeng; Wei, Haiming; Sun, Rui; Tian, Zhigang; Zheng, Xiaodong

    2016-02-01

    Bradford assay is one of the most common methods for measuring protein concentrations. However, some pharmaceutical excipients, such as detergents, interfere with Bradford assay even at low concentrations. Protein precipitation can be used to overcome sample incompatibility with protein quantitation. But the rate of protein recovery caused by acetone precipitation is only about 70%. In this study, we found that sucrose not only could increase the rate of protein recovery after 1 h acetone precipitation, but also did not interfere with Bradford assay. So we developed a method for rapid protein quantitation in protein drugs even if they contained interfering substances. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. A rapid method of reprocessing for electronic microscopy of cut histological in paraffin

    International Nuclear Information System (INIS)

    Hernandez Chavarri, F.; Vargas Montero, M.; Rivera, P.; Carranza, A.

    2000-01-01

    A simple and rapid method is described for re-processing of light microscopy paraffin sections to observe they under transmission electron microscopy (TEM) and scanning electron microscopy (SEM) The paraffin-embedded tissue is sectioned and deparaffinized in toluene; then exposed to osmium vapor under microwave irradiation using a domestic microwave oven. The tissues were embedded in epoxy resin, polymerized and ultrathin sectioned. The method requires a relatively short time (about 30 minutes for TEM and 15 for SEM), and produces a reasonable quality of the ultrastructure for diagnostic purposes. (Author) [es

  19. A rapid method for the computation of equilibrium chemical composition of air to 15000 K

    Science.gov (United States)

    Prabhu, Ramadas K.; Erickson, Wayne D.

    1988-01-01

    A rapid computational method has been developed to determine the chemical composition of equilibrium air to 15000 K. Eleven chemically reacting species, i.e., O2, N2, O, NO, N, NO+, e-, N+, O+, Ar, and Ar+ are included. The method involves combining algebraically seven nonlinear equilibrium equations and four linear elemental mass balance and charge neutrality equations. Computational speeds for determining the equilibrium chemical composition are significantly faster than the often used free energy minimization procedure. Data are also included from which the thermodynamic properties of air can be computed. A listing of the computer program together with a set of sample results are included.

  20. N-nitrosodimethylamine in drinking water using a rapid, solid-phase extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S W.D. [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Koester, C J [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Taguchi, V Y [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Wang, D T [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Palmentier, J P.F.P. [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Hong, K P [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch

    1995-12-01

    A simple, rapid method for the extraction of N-nitrosodimethylamine (NDMA) from drinking and surface waters was developed using Ambersorb 572. Development of an alternative method to classical liquid-liquid extraction techniques was necessary to handle the workload presented by implementation of a provincial guideline of 9 ppt for drinking water and a regulatory level of 200 ppt for effluents. A granular absorbent, Ambersorb 572, was used to extract the NDMA from the water in the sample bottle. The NDMA was extracted from the Ambersorb 572 with dichloromethane in the autosampler vial. Method characteristics include a precision of 4% for replicate analyses, and accuracy of 6% at 10 ppt and a detection limit of 1.0 ppt NDMA in water. Comparative data between the Ambersorb 572 method and liquid-liquid extraction showed excellent agreement (average difference of 12%). With the Ambersorb 572 method, dichloromethane use has been reduced by a factor of 1,000 and productivity has been increased by a factor of 3-4. Monitoring of a drinking water supply showed rapidly changing concentrations of NDMA from day to day. (orig.)

  1. An optimized rapid bisulfite conversion method with high recovery of cell-free DNA.

    Science.gov (United States)

    Yi, Shaohua; Long, Fei; Cheng, Juanbo; Huang, Daixin

    2017-12-19

    Methylation analysis of cell-free DNA is a encouraging tool for tumor diagnosis, monitoring and prognosis. Sensitivity of methylation analysis is a very important matter due to the tiny amounts of cell-free DNA available in plasma. Most current methods of DNA methylation analysis are based on the difference of bisulfite-mediated deamination of cytosine between cytosine and 5-methylcytosine. However, the recovery of bisulfite-converted DNA based on current methods is very poor for the methylation analysis of cell-free DNA. We optimized a rapid method for the crucial steps of bisulfite conversion with high recovery of cell-free DNA. A rapid deamination step and alkaline desulfonation was combined with the purification of DNA on a silica column. The conversion efficiency and recovery of bisulfite-treated DNA was investigated by the droplet digital PCR. The optimization of the reaction results in complete cytosine conversion in 30 min at 70 °C and about 65% of recovery of bisulfite-treated cell-free DNA, which is higher than current methods. The method allows high recovery from low levels of bisulfite-treated cell-free DNA, enhancing the analysis sensitivity of methylation detection from cell-free DNA.

  2. A rapid Salmonella detection method involving thermophilic helicase-dependent amplification and a lateral flow assay.

    Science.gov (United States)

    Du, Xin-Jun; Zhou, Tian-Jiao; Li, Ping; Wang, Shuo

    2017-08-01

    Salmonella is a major foodborne pathogen that is widespread in the environment and can cause serious human and animal disease. Since conventional culture methods to detect Salmonella are time-consuming and laborious, rapid and accurate techniques to detect this pathogen are critically important for food safety and diagnosing foodborne illness. In this study, we developed a rapid, simple and portable Salmonella detection strategy that combines thermophilic helicase-dependent amplification (tHDA) with a lateral flow assay to provide a detection result based on visual signals within 90 min. Performance analyses indicated that the method had detection limits for DNA and pure cultured bacteria of 73.4-80.7 fg and 35-40 CFU, respectively. Specificity analyses showed no cross reactions with Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, Enterobacter aerogenes, Shigella and Campylobacter jejuni. The results for detection in real food samples showed that 1.3-1.9 CFU/g or 1.3-1.9 CFU/mL of Salmonella in contaminated chicken products and infant nutritional cereal could be detected after 2 h of enrichment. The same amount of Salmonella in contaminated milk could be detected after 4 h of enrichment. This tHDA-strip can be used for the rapid detection of Salmonella in food samples and is particularly suitable for use in areas with limited equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Radiometric--microbiologic assay of vitamin B-6: application to food analysis

    International Nuclear Information System (INIS)

    Guilarte, T.R.; Shane, B.; McIntyre, P.A.

    1981-01-01

    A radiometric microbiologic assay for vitamin B-6 was applied to food analysis. The method was shown to be specific, reproducible and simpler than the standard turbidimetric microbiologic technique. The analysis of seven commercially available breakfast cereals was compared to a high performance liquid chromatography method. Three out of the seven cereals agreed when assayed with both methods (P greater than 0.1). Four cereals, however, differed in value considerably (P less than 0.05). Further studies are required to determine whether these differences were due to different extraction procedures used. The study showed that the new radiometric-microbiologic method can be used to measure total vitamin B-6 or, combined with a column separation procedure, to analyze for specific forms of the vitamin

  4. The performance studies of DKDP crystals grown by a rapid horizontal growth method

    Science.gov (United States)

    Xie, Xiaoyi; Qi, Hongji; Wang, Bin; Wang, Hu; Chen, Duanyang; Shao, Jianda

    2018-04-01

    A deuterated potassium dihydrogen phosphate (DKDP) crystal with about 70% deuterium level was grown by a rapid horizontal growth method with independent design equipment, which includes a continuous filtration system. The cooling program during crystal growth was designed according to a self-developed software to catch the size of growing crystal in real time. The crystal structure, optical performance and laser induced damage threshold (LIDT) of this DKDP crystal were investigated in this paper. The deuterium concentration of the crystal was confirmed by the neutron diffraction technique, which was effective and available in determining a complete range of deuteration level. The dielectric property was measured to evaluate the perfection of the lattice. The transmittance and LIDT were carried out further to evaluate the optical and functional properties of this DKDP crystal grown in the rapid horizontal growth technique. All of the detailed characterization for DKDP figured out that the 70% deuterated KDP crystal grown in this way had relatively good qualities.

  5. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  6. A new semiquantitative radiometric opsonin assay

    International Nuclear Information System (INIS)

    Yamamura, M.; Valdimarsson, H.

    1978-01-01

    A new semiquantitative radiometric opsonin assay is described. It was found that the opsonin activity generated by incubating brewer's yeast, Saccharomyces cerevisiae, in medium containing less than 5% human serum was exclusively complement dependent. In contrast, C.albicans was effectively opsonized in the absence of complement. Antibodies and the early classical complement pathway did not contribute to the opsonization of S.cerevisiae and neither did C5-9. The brewer's yeast assay can therefore be used for measuring selectively the opsonizing capacity of the alternative pathway. Sera from approximately 7% of apparently healthy adult controls consistently failed to generate significant opsonin activity while 8 out of 26 patients with suspected immune deficiency of unknown cause were defective in this assay. All opsonin deficient sera so far tested had haemolytically normal alternative pathway and Factor B activity. (author)

  7. Radiometric sorting of Rio Algom uranium ore

    International Nuclear Information System (INIS)

    Cristovici, M.A.

    1983-11-01

    An ore sample of about 0.2 percent uranium from Quirke Mine was subjected to radiometric sorting by Ore Sorters Limited. Approximately 60 percent of the sample weight fell within the sortable size range: -150 + 25 mm. Rejects of low uranium content ( 2 (2 counts/in 2 ) but only 7.6 percent of the ore, by weight, was discarded. At 0.8-0.9 counts/cm 2 (5-6 counts/in 2 ) a significant amount of rejects was removed (> 25 percent) but the uranium loss was unacceptably high (7.7 percent). Continuation of the testwork to improve the results is proposed by trying to extend the sortable size range and to reduce the amount of fines during crushing

  8. Importance of radiometric survey in radiodiagnosis installationscalculated

    International Nuclear Information System (INIS)

    Leyton, Fernando; Alarcon, Luis; Zapata, Victor H.; Ortega, Dulia; Ramirez, Alfredo; Aravena, Gonzalo; Ubeda, Carlos; Oyarzun, Carlos; Inzulza, Alonso

    2005-01-01

    A radiometric survey was conducted in two services of imaging with a total of 7 evaluated radiology rooms. The Quality Control Protocol methodology was used in Radiology ARCAL (Regional Agreement of cooperation for the promotion of nuclear science and technology in Latin America and the Caribbean) XLIX of the International Atomic Energy Agency (IAEA). The effective dose in different positions of interest rates were calculated, from the point of view of radiation protection. All evaluated rooms have rates of effective doses that meet the values limits set in the Protocol ARCAL XLIX, for 82% of the positions evaluated. However operators located in the position A (controlled area) exceed on average 370% with a range of [1-870] the limit proposed by ARCAL XLIX

  9. Spectrometric devices of itinerant radiometric laboratory

    International Nuclear Information System (INIS)

    Dolgirev, E.I.; Moroz, G.L.; Shchedrin, D.A.

    1978-01-01

    Scintillation gamma-spectrometer is described designed for mobile radiometric laboratory for individual monitoring of internal γ-radiation of members of the general population and service personnel as well as for analysis of the isotopic composition of radiocontaminants in the environment. Description and technical features of device are given. The detection unit consists of detectors made on the basis of NaI(Tl) monocrystals 63 x 63 mm in size. The unit permits measurement of various levels of gamma-emitting nuclides throughout the body and in the thyroid and lungs of man. Provision is made for measuring samples with high specific activities (more than 10 -5 Cu/g) and for examining individuals having high levels of incorporated radionuclides

  10. Radiometric monitoring outdoor municipality Pocinhos-PB

    International Nuclear Information System (INIS)

    Cardinalli Araujo Costa, Michelle; Araujo dos Santos Junior, Jose; Dos Santos Amaral, Romilton

    2015-01-01

    Studies on human exposure to terrestrial radionuclides are important for human health. Therefore, this investigation presents aimed at making radiometric dosimetry Pocinhos municipality in the state of Paraiba. Monitoring was performed in 50 points in urban and rural areas Pocinhos. The estimated external effective dose rate in outdoor environments was obtained in triplicate using a portable gamma spectrometer, to 1.0 m away from the Earth's surface and time set acquisition in terms of environmental radiation levels. The values of these dose rates outdoor environments ranging from 0.53 to 3.94 mSv.y -1 . the arithmetic mean was 0.79 mSv.y -1 , which exceeds the value 0.07 mSv.y -1 corresponding to the global average in outdoor environments. In the city, found a higher radioactivity in rural areas that were uninhabited at the time of the survey. (Author)

  11. MSFIA-LOV system for {sup 226}Ra isolation and pre-concentration from water samples previous radiometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez, Rogelio [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Borràs, Antoni [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Leal, Luz [Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Cerdà, Víctor [Department of Chemistry, University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Ferrer, Laura, E-mail: laura.ferrer@uib.es [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain)

    2016-03-10

    An automatic system based on multisyringe flow injection analysis (MSFIA) and lab-on-valve (LOV) flow techniques for separation and pre-concentration of {sup 226}Ra from drinking and natural water samples has been developed. The analytical protocol combines two different procedures: the Ra adsorption on MnO{sub 2} and the BaSO{sub 4} co-precipitation, achieving more selectivity especially in water samples with low radium levels. Radium is adsorbed on MnO{sub 2} deposited on macroporous of bead cellulose. Then, it is eluted with hydroxylamine to transform insoluble MnO{sub 2} to soluble Mn(II) thus freeing Ra, which is then coprecipitated with BaSO{sub 4}. The {sup 226}Ra can be directly detected in off-line mode using a low background proportional counter (LBPC) or through a liquid scintillation counter (LSC), after performing an on-line coprecipitate dissolution. Thus, the versatility of the proposed system allows the selection of the radiometric detection technique depending on the detector availability or the required response efficiency (sample number vs. response time and limit of detection). The MSFIA-LOV system improves the precision (1.7% RSD), and the extraction frequency (up to 3 h{sup −1}). Besides, it has been satisfactorily applied to different types of water matrices (tap, mineral, well and sea water). The {sup 226}Ra minimum detectable activities (LSC: 0.004 Bq L{sup −1}; LBPC: 0.02 Bq L{sup −1}) attained by this system allow to reach the guidance values proposed by the relevant international agencies e.g. WHO, EPA and EC. - Highlights: • Automatic, rapid and selective method for {sup 226}Ra extraction/pre-concentration from water. • MSFIA-LOV system performs a sample clean-up prior to {sup 226}Ra radiometric detection. • {sup 226}Ra sample preparation allows using two radiometric detectors (LBPC and LSC). • Environmental levels of {sup 226}Ra are easily quantified. • High sensitivity and selectivity are achieved, reaching the

  12. A rapid and specific titrimetric method for the precise determination of plutonium using redox indicator

    International Nuclear Information System (INIS)

    Chitnis, R.T.; Dubey, S.C.

    1976-01-01

    A simple and rapid method for the determination of plutonium in plutonium nitrate solution and its application to the purex process solutions is discussed. The method involves the oxidation of plutonium to Pu(VI) with the help of argentic oxide followed by the destruction of the excess argentic oxide by means of sulphamic acid. The determination of plutonium is completed by adding ferrous ammonium sulphate solution which reduces Pu(VI) to Pu(IV) and titrating the excess ferrous with standard potassium dichromate solution using sodium diphenylamine sulphonate as the internal indicator. The effect of the various reagents add during the oxidation and reduction of plutonium, on the final titration has been investigated. The method works satisfactorily for the analysis of plutonium in the range of 0.5 to 5 mg. The precision of the method is found to be within 0.1%. (author)

  13. New modelling method for fast reactor neutronic behaviours analysis; Nouvelles methodes de modelisation neutronique des reacteurs rapides de quatrieme Generation

    Energy Technology Data Exchange (ETDEWEB)

    Jacquet, P.

    2011-05-23

    Due to safety rules running on fourth generation reactors' core development, neutronics simulation tools have to be as accurate as never before. First part of this report enumerates every step of fast reactor's neutronics simulation implemented in current reference code: ECCO. Considering the field of fast reactors that meet criteria of fourth generation, ability of models to describe self-shielding phenomenon, to simulate neutrons leakage in a lattice of fuel assemblies and to produce representative macroscopic sections is evaluated. The second part of this thesis is dedicated to the simulation of fast reactors' core with steel reflector. These require the development of advanced methods of condensation and homogenization. Several methods are proposed and compared on a typical case: the ZONA2B core of MASURCA reactor. (author) [French] Les criteres de surete qui regissent le developpement de coeurs de reacteurs de quatrieme generation implique l'usage d'outils de calcul neutronique performants. Une premiere partie de la these reprend toutes les etapes de modelisation neutronique des reacteurs rapides actuellement d'usage dans le code de reference ECCO. La capacite des modeles a decrire le phenomene d'autoprotection, a representer les fuites neutroniques au niveau d'un reseau d'assemblages combustibles et a generer des sections macroscopiques representatives est appreciee sur le domaine des reacteurs rapides innovants respectant les criteres de quatrieme generation. La deuxieme partie de ce memoire se consacre a la modelisation des coeurs rapides avec reflecteur acier. Ces derniers necessitent le developpement de methodes avancees de condensation et d'homogenisation. Plusieurs methodes sont proposees et confrontees sur un probleme de modelisation typique: le coeur ZONA2B du reacteur maquette MASURCA

  14. Rapid-viability PCR method for detection of live, virulent Bacillus anthracis in environmental samples.

    Science.gov (United States)

    Létant, Sonia E; Murphy, Gloria A; Alfaro, Teneile M; Avila, Julie R; Kane, Staci R; Raber, Ellen; Bunt, Thomas M; Shah, Sanjiv R

    2011-09-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples.

  15. A rapid colorimetric screening method for vanillic acid and vanillin-producing bacterial strains.

    Science.gov (United States)

    Zamzuri, N A; Abd-Aziz, S; Rahim, R A; Phang, L Y; Alitheen, N B; Maeda, T

    2014-04-01

    To isolate a bacterial strain capable of biotransforming ferulic acid, a major component of lignin, into vanillin and vanillic acid by a rapid colorimetric screening method. For the production of vanillin, a natural aroma compound, we attempted to isolate a potential strain using a simple screening method based on pH change resulting from the degradation of ferulic acid. The strain Pseudomonas sp. AZ10 UPM exhibited a significant result because of colour changes observed on the assay plate on day 1 with a high intensity of yellow colour. The biotransformation of ferulic acid into vanillic acid by the AZ10 strain provided the yield (Yp/s ) and productivity (Pr ) of 1·08 mg mg(-1) and 53·1 mg L(-1) h(-1) , respectively. In fact, new investigations regarding lignin degradation revealed that the strain was not able to produce vanillin and vanillic acid directly from lignin; however, partially digested lignin by mixed enzymatic treatment allowed the strain to produce 30·7 mg l(-1) and 1·94 mg l(-1) of vanillic acid and biovanillin, respectively. (i) The rapid colorimetric screening method allowed the isolation of a biovanillin producer using ferulic acid as the sole carbon source. (ii) Enzymatic treatment partially digested lignin, which could then be utilized by the strain to produce biovanillin and vanillic acid. To the best of our knowledge, this is the first study reporting the use of a rapid colorimetric screening method for bacterial strains producing vanillin and vanillic acid from ferulic acid. © 2013 The Society for Applied Microbiology.

  16. [Accuracy of three methods for the rapid diagnosis of oral candidiasis].

    Science.gov (United States)

    Lyu, X; Zhao, C; Yan, Z M; Hua, H

    2016-10-09

    Objective: To explore a simple, rapid and efficient method for the diagnosis of oral candidiasis in clinical practice. Methods: Totally 124 consecutive patients with suspected oral candidiasis were enrolled from Department of Oral Medicine, Peking University School and Hospital of Stomatology, Beijing, China. Exfoliated cells of oral mucosa and saliva or concentrated oral rinse) obtained from all participants were tested by three rapid smear methods(10% KOH smear, gram-stained smear, Congo red stained smear). The diagnostic efficacy(sensitivity, specificity, Youden's index, likelihood ratio, consistency, predictive value and area under curve(AUC) of each of the above mentioned three methods was assessed by comparing the results with the gold standard(combination of clinical diagnosis, laboratory diagnosis and expert opinion). Results: Gram-stained smear of saliva(or concentrated oral rinse) demonstrated highest sensitivity(82.3%). Test of 10%KOH smear of exfoliated cells showed highest specificity(93.5%). Congo red stained smear of saliva(or concentrated oral rinse) displayed highest diagnostic efficacy(79.0% sensitivity, 80.6% specificity, 0.60 Youden's index, 4.08 positive likelihood ratio, 0.26 negative likelihood ratio, 80% consistency, 80.3% positive predictive value, 79.4% negative predictive value and 0.80 AUC). Conclusions: Test of Congo red stained smear of saliva(or concentrated oral rinse) could be used as a point-of-care tool for the rapid diagnosis of oral candidiasis in clinical practice. Trial registration: Chinese Clinical Trial Registry, ChiCTR-DDD-16008118.

  17. Comparing models of rapidly rotating relativistic stars constructed by two numerical methods

    Science.gov (United States)

    Stergioulas, Nikolaos; Friedman, John L.

    1995-05-01

    We present the first direct comparison of codes based on two different numerical methods for constructing rapidly rotating relativistic stars. A code based on the Komatsu-Eriguchi-Hachisu (KEH) method (Komatsu et al. 1989), written by Stergioulas, is compared to the Butterworth-Ipser code (BI), as modified by Friedman, Ipser, & Parker. We compare models obtained by each method and evaluate the accuracy and efficiency of the two codes. The agreement is surprisingly good, and error bars in the published numbers for maximum frequencies based on BI are dominated not by the code inaccuracy but by the number of models used to approximate a continuous sequence of stars. The BI code is faster per iteration, and it converges more rapidly at low density, while KEH converges more rapidly at high density; KEH also converges in regions where BI does not, allowing one to compute some models unstable against collapse that are inaccessible to the BI code. A relatively large discrepancy recently reported (Eriguchi et al. 1994) for models based on Friedman-Pandharipande equation of state is found to arise from the use of two different versions of the equation of state. For two representative equations of state, the two-dimensional space of equilibrium configurations is displayed as a surface in a three-dimensional space of angular momentum, mass, and central density. We find, for a given equation of state, that equilibrium models with maximum values of mass, baryon mass, and angular momentum are (generically) either all unstable to collapse or are all stable. In the first case, the stable model with maximum angular velocity is also the model with maximum mass, baryon mass, and angular momentum. In the second case, the stable models with maximum values of these quantities are all distinct. Our implementation of the KEH method will be available as a public domain program for interested users.

  18. Statistical Techniques Applied to Aerial Radiometric Surveys (STAARS): cluster analysis. National Uranium Resource Evaluation

    International Nuclear Information System (INIS)

    Pirkle, F.L.; Stablein, N.K.; Howell, J.A.; Wecksung, G.W.; Duran, B.S.

    1982-11-01

    One objective of the aerial radiometric surveys flown as part of the US Department of Energy's National Uranium Resource Evaluation (NURE) program was to ascertain the regional distribution of near-surface radioelement abundances. Some method for identifying groups of observations with similar radioelement values was therefore required. It is shown in this report that cluster analysis can identify such groups even when no a priori knowledge of the geology of an area exists. A method of convergent k-means cluster analysis coupled with a hierarchical cluster analysis is used to classify 6991 observations (three radiometric variables at each observation location) from the Precambrian rocks of the Copper Mountain, Wyoming, area. Another method, one that combines a principal components analysis with a convergent k-means analysis, is applied to the same data. These two methods are compared with a convergent k-means analysis that utilizes available geologic knowledge. All three methods identify four clusters. Three of the clusters represent background values for the Precambrian rocks of the area, and one represents outliers (anomalously high 214 Bi). A segmentation of the data corresponding to geologic reality as discovered by other methods has been achieved based solely on analysis of aerial radiometric data. The techniques employed are composites of classical clustering methods designed to handle the special problems presented by large data sets. 20 figures, 7 tables

  19. Note: Non-invasive optical method for rapid determination of alignment degree of oriented nanofibrous layers

    Energy Technology Data Exchange (ETDEWEB)

    Pokorny, M.; Rebicek, J. [R& D Department, Contipro Biotech s.r.o., 561 02 Dolni Dobrouc (Czech Republic); Klemes, J. [R& D Department, Contipro Pharma a.s., 561 02 Dolni Dobrouc (Czech Republic); Kotzianova, A. [R& D Department, Contipro Pharma a.s., 561 02 Dolni Dobrouc (Czech Republic); Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, CZ-62500 Brno (Czech Republic); Velebny, V. [R& D Department, Contipro Biotech s.r.o., 561 02 Dolni Dobrouc (Czech Republic); R& D Department, Contipro Pharma a.s., 561 02 Dolni Dobrouc (Czech Republic)

    2015-10-15

    This paper presents a rapid non-destructive method that provides information on the anisotropic internal structure of nanofibrous layers. A laser beam of a wavelength of 632.8 nm is directed at and passes through a nanofibrous layer prepared by electrostatic spinning. Information about the structural arrangement of nanofibers in the layer is directly visible in the form of a diffraction image formed on a projection screen or obtained from measured intensities of the laser beam passing through the sample which are determined by the dependency of the angle of the main direction of polarization of the laser beam on the axis of alignment of nanofibers in the sample. Both optical methods were verified on Polyvinyl alcohol (PVA) nanofibrous layers (fiber diameter of 470 nm) with random, single-axis aligned and crossed structures. The obtained results match the results of commonly used methods which apply the analysis of electron microscope images. The presented simple method not only allows samples to be analysed much more rapidly and without damaging them but it also makes possible the analysis of much larger areas, up to several square millimetres, at the same time.

  20. Note: Non-invasive optical method for rapid determination of alignment degree of oriented nanofibrous layers

    International Nuclear Information System (INIS)

    Pokorny, M.; Rebicek, J.; Klemes, J.; Kotzianova, A.; Velebny, V.

    2015-01-01

    This paper presents a rapid non-destructive method that provides information on the anisotropic internal structure of nanofibrous layers. A laser beam of a wavelength of 632.8 nm is directed at and passes through a nanofibrous layer prepared by electrostatic spinning. Information about the structural arrangement of nanofibers in the layer is directly visible in the form of a diffraction image formed on a projection screen or obtained from measured intensities of the laser beam passing through the sample which are determined by the dependency of the angle of the main direction of polarization of the laser beam on the axis of alignment of nanofibers in the sample. Both optical methods were verified on Polyvinyl alcohol (PVA) nanofibrous layers (fiber diameter of 470 nm) with random, single-axis aligned and crossed structures. The obtained results match the results of commonly used methods which apply the analysis of electron microscope images. The presented simple method not only allows samples to be analysed much more rapidly and without damaging them but it also makes possible the analysis of much larger areas, up to several square millimetres, at the same time

  1. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    Science.gov (United States)

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  2. A two-step method for rapid characterization of electroosmotic flows in capillary electrophoresis.

    Science.gov (United States)

    Zhang, Wenjing; He, Muyi; Yuan, Tao; Xu, Wei

    2017-12-01

    The measurement of electroosmotic flow (EOF) is important in a capillary electrophoresis (CE) experiment in terms of performance optimization and stability improvement. Although several methods exist, there are demanding needs to accurately characterize ultra-low electroosmotic flow rates (EOF rates), such as in coated capillaries used in protein separations. In this work, a new method, called the two-step method, was developed to accurately and rapidly measure EOF rates in a capillary, especially for measuring the ultra-low EOF rates in coated capillaries. In this two-step method, the EOF rates were calculated by measuring the migration time difference of a neutral marker in two consecutive experiments, in which a pressure driven was introduced to accelerate the migration and the DC voltage was reversed to switch the EOF direction. Uncoated capillaries were first characterized by both this two-step method and a conventional method to confirm the validity of this new method. Then this new method was applied in the study of coated capillaries. Results show that this new method is not only fast in speed, but also better in accuracy. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Hierarchically rough, mechanically durable and superhydrophobic epoxy coatings through rapid evaporation spray method

    International Nuclear Information System (INIS)

    Simovich, Tomer; Wu, Alex H.; Lamb, Robert N.

    2015-01-01

    A mechanically durable and scalable superhydrophobic coating was fabricated by combining the advantages of both bottom-up and top-down approaches into a one-pot, one-step application method. This is achieved by spray coating a solution consisting of silica nanoparticles, which are embedded within epoxy resin, onto a heated substrate to rapidly drive both solvent evaporation and curing simultaneously. By maintaining a high substrate temperature, the arrival of spray-delivered micrometer-sized droplets are rapidly cured onto the substrate to form surface microroughness, while simultaneously, rapid solvent evaporation within each droplet results in the formation of a nanoporous structure. SEM, dual-beam FIB, and cross-sectional TEM/EDAX elemental mapping were used to confirm both the chemistry and the requisite micro- and nano-porosity within the coating structure requisite for superhydrophobicity. The resultant coatings exhibit contact angles greater than 150° (153.8° ± 0.8°) and roll-off angles of 8° ± 2°, with a coating hardness of 6H on the pencil hardness scale, and a rating of 5 on an ASTM crosshatch test. - Highlights: • A highly superhydrophobic coating was fabricated utilizing epoxy and nanoparticles. • The coating was demonstrated to be very durable and abrasion resistant. • The fabrication involves a novel, scalable one-pot synthesis technique

  4. Hierarchically rough, mechanically durable and superhydrophobic epoxy coatings through rapid evaporation spray method

    Energy Technology Data Exchange (ETDEWEB)

    Simovich, Tomer; Wu, Alex H.; Lamb, Robert N., E-mail: rnlamb@unimelb.edu.au

    2015-08-31

    A mechanically durable and scalable superhydrophobic coating was fabricated by combining the advantages of both bottom-up and top-down approaches into a one-pot, one-step application method. This is achieved by spray coating a solution consisting of silica nanoparticles, which are embedded within epoxy resin, onto a heated substrate to rapidly drive both solvent evaporation and curing simultaneously. By maintaining a high substrate temperature, the arrival of spray-delivered micrometer-sized droplets are rapidly cured onto the substrate to form surface microroughness, while simultaneously, rapid solvent evaporation within each droplet results in the formation of a nanoporous structure. SEM, dual-beam FIB, and cross-sectional TEM/EDAX elemental mapping were used to confirm both the chemistry and the requisite micro- and nano-porosity within the coating structure requisite for superhydrophobicity. The resultant coatings exhibit contact angles greater than 150° (153.8° ± 0.8°) and roll-off angles of 8° ± 2°, with a coating hardness of 6H on the pencil hardness scale, and a rating of 5 on an ASTM crosshatch test. - Highlights: • A highly superhydrophobic coating was fabricated utilizing epoxy and nanoparticles. • The coating was demonstrated to be very durable and abrasion resistant. • The fabrication involves a novel, scalable one-pot synthesis technique.

  5. Pressure-jump induced rapid solidification of melt: a method of preparing amorphous materials

    Science.gov (United States)

    Liu, Xiuru; Jia, Ru; Zhang, Doudou; Yuan, Chaosheng; Shao, Chunguang; Hong, Shiming

    2018-04-01

    By using a self-designed pressure-jump apparatus, we investigated the melt solidification behavior in rapid compression process for several kinds of materials, such as elementary sulfur, polymer polyether-ether-ketone (PEEK) and poly-ethylene-terephthalate, alloy La68Al10Cu20Co2 and Nd60Cu20Ni10Al10. Experimental results clearly show that their melts could be solidified to be amorphous states through the rapid compression process. Bulk amorphous PEEK with 24 mm in diameter and 12 mm in height was prepared, which exceeds the size obtained by melt quenching method. The bulk amorphous sulfur thus obtained exhibited extraordinarily high thermal stability, and an abnormal exothermic transition to liquid sulfur was observed at around 396 K for the first time. Furthermore, it is suggested that the glass transition pressure and critical compression rate exist to form the amorphous phase. This approach of rapid compression is very attractive not only because it is a new technique of make bulk amorphous materials, but also because novel properties are expected in the amorphous materials solidified by the pressure-jump within milliseconds or microseconds.

  6. A rapid and sensitive method for measuring N-acetylglucosaminidase activity in cultured cells.

    Directory of Open Access Journals (Sweden)

    Victor Mauri

    Full Text Available A rapid and sensitive method to quantitatively assess N-acetylglucosaminidase (NAG activity in cultured cells is highly desirable for both basic research and clinical studies. NAG activity is deficient in cells from patients with Mucopolysaccharidosis type IIIB (MPS IIIB due to mutations in NAGLU, the gene that encodes NAG. Currently available techniques for measuring NAG activity in patient-derived cell lines include chromogenic and fluorogenic assays and provide a biochemical method for the diagnosis of MPS IIIB. However, standard protocols require large amounts of cells, cell disruption by sonication or freeze-thawing, and normalization to the cellular protein content, resulting in an error-prone procedure that is material- and time-consuming and that produces highly variable results. Here we report a new procedure for measuring NAG activity in cultured cells. This procedure is based on the use of the fluorogenic NAG substrate, 4-Methylumbelliferyl-2-acetamido-2-deoxy-alpha-D-glucopyranoside (MUG, in a one-step cell assay that does not require cell disruption or post-assay normalization and that employs a low number of cells in 96-well plate format. We show that the NAG one-step cell assay greatly discriminates between wild-type and MPS IIIB patient-derived fibroblasts, thus providing a rapid method for the detection of deficiencies in NAG activity. We also show that the assay is sensitive to changes in NAG activity due to increases in NAGLU expression achieved by either overexpressing the transcription factor EB (TFEB, a master regulator of lysosomal function, or by inducing TFEB activation chemically. Because of its small format, rapidity, sensitivity and reproducibility, the NAG one-step cell assay is suitable for multiple procedures, including the high-throughput screening of chemical libraries to identify modulators of NAG expression, folding and activity, and the investigation of candidate molecules and constructs for applications in

  7. A Rapid and Cost-Effective Method for DNA Extraction from Archival Herbarium Specimens.

    Science.gov (United States)

    Krinitsina, A A; Sizova, T V; Zaika, M A; Speranskaya, A S; Sukhorukov, A P

    2015-11-01

    Here we report a rapid and cost-effective method for the extraction of total DNA from herbarium specimens up to 50-90-year-old. The method takes about 2 h, uses AMPure XP magnetic beads diluted by PEG-8000- containing buffer, and does not require use of traditional volatile components like chloroform, phenol, and liquid nitrogen. It yields up to 4 µg of total nucleic acid with high purity from about 30 mg of dry material. The quality of the extracted DNA was tested by PCR amplification of 5S rRNA and rbcL genes (nuclear and chloroplast DNA markers) and compared against the traditional chloroform/isoamyl alcohol method. Our results demonstrate that the use of the magnetic beads is crucial for extraction of DNA suitable for subsequent PCR from herbarium samples due to the decreasing inhibitor concentrations, reducing short fragments of degraded DNA, and increasing median DNA fragment sizes.

  8. Validation and application of an improved method for the rapid determination of proline in grape berries.

    Science.gov (United States)

    Rienth, Markus; Romieu, Charles; Gregan, Rebecca; Walsh, Caroline; Torregrosa, Laurent; Kelly, Mary T

    2014-04-16

    A rapid and sensitive method is presented for the determination of proline in grape berries. Following acidification with formic acid, proline is derivatized by heating at 100 °C for 15 min with 3% ninhydrin in dimethyl sulfoxide, and the absorbance, which is stable for at least 60 min, is read at 520 nm. The method was statistically validated in the concentration range from 2.5 to 15 mg/L, giving a repeatability and intermediate precision of generally amino acid analyzer. In terms of sample preparation, a simple dilution (5-20-fold) is required, and sugars, primary amino acids, and anthocyanins were demonstrated not to interfere, as the latter are bleached by ninhydrin under the experimental conditions. The method was applied to the study of proline accumulation in the fruits of microvines grown in phytotrons, and it was established that proline accumulation and concentrations closely resemble those of field-grown macrovines.

  9. Rapid synthesis of single-phase bismuth ferrite by microwave-assisted hydrothermal method

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Wenqian [College of Materials Science and Engineering, China Jiliang University, 258 Xueyuan Street, Xiasha Higher Education District, Hangzhou 310018, Zhejiang Province (China); Chen, Zhi, E-mail: zchen0@gmail.com [College of Materials Science and Engineering, China Jiliang University, 258 Xueyuan Street, Xiasha Higher Education District, Hangzhou 310018, Zhejiang Province (China); Gao, Tong; Zhou, Dantong; Leng, Xiaonan; Niu, Feng [College of Materials Science and Engineering, China Jiliang University, 258 Xueyuan Street, Xiasha Higher Education District, Hangzhou 310018, Zhejiang Province (China); Zhu, Yuxiang [College of Materials Science and Engineering, China Jiliang University, 258 Xueyuan Street, Xiasha Higher Education District, Hangzhou 310018, Zhejiang Province (China); Tianjin Key Laboratory of Marine Resources and Chemistry, Tianjin University of Science and Technology, Tianjin (China); Qin, Laishun, E-mail: qinlaishun@yeah.net [College of Materials Science and Engineering, China Jiliang University, 258 Xueyuan Street, Xiasha Higher Education District, Hangzhou 310018, Zhejiang Province (China); Wang, Jiangying; Huang, Yuexiang [College of Materials Science and Engineering, China Jiliang University, 258 Xueyuan Street, Xiasha Higher Education District, Hangzhou 310018, Zhejiang Province (China)

    2016-06-01

    This paper describes on the fast synthesis of bismuth ferrite by the simple microwave-assisted hydrothermal method. The phase transformation and the preferred growth facets during the synthetic process have been investigated by X-ray diffraction. Bismuth ferrite can be quickly prepared by microwave hydrothermal method by simply controlling the reaction time, which is further confirmed by Fourier Transform infrared spectroscopy and magnetic measurement. - Graphical abstract: Single-phase BiFeO{sub 3} could be realized at a shortest reaction time of 65 min. The reaction time has strong influences on the phase transformation and the preferred growth facets. - Highlights: • Rapid synthesis (65 min) of BiFeO{sub 3} by microwave-assisted hydrothermal method. • Reaction time has influence on the purity and preferred growth facets. • FTIR and magnetic measurement further confirm the pure phase.

  10. Rapid bioassay method for estimation of 90Sr in urine samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Chaudhary, Seema; Sawant, Pramilla D.

    2018-01-01

    Radiostrontium (Sr) is a by-product of the nuclear fission of uranium and plutonium in nuclear reactors and is an important radionuclide in spent nuclear fuel and radioactive waste. Rapid bioassay methods are required for estimating Sr in urine following internal contamination. Decision regarding medical intervention, if any can be based upon the results of urinalysis. The present method used at Bioassay Laboratory, Trombay is by Solid Extraction Chromatography (SEC) technique. The Sr separated from urine sample is precipitated as SrCO 3 and analyzed gravimetrically. However, gravimetric procedure is time consuming and therefore, in the present study, feasibility of Liquid Scintillation Counting for direct detection of radiostrontium in effluent was explored. The results obtained in the present study were compared with those obtained using gravimetric method

  11. Are rapid population estimates accurate? A field trial of two different assessment methods.

    Science.gov (United States)

    Grais, Rebecca F; Coulombier, Denis; Ampuero, Julia; Lucas, Marcelino E S; Barretto, Avertino T; Jacquier, Guy; Diaz, Francisco; Balandine, Serge; Mahoudeau, Claude; Brown, Vincent

    2006-09-01

    Emergencies resulting in large-scale displacement often lead to populations resettling in areas where basic health services and sanitation are unavailable. To plan relief-related activities quickly, rapid population size estimates are needed. The currently recommended Quadrat method estimates total population by extrapolating the average population size living in square blocks of known area to the total site surface. An alternative approach, the T-Square, provides a population estimate based on analysis of the spatial distribution of housing units taken throughout a site. We field tested both methods and validated the results against a census in Esturro Bairro, Beira, Mozambique. Compared to the census (population: 9,479), the T-Square yielded a better population estimate (9,523) than the Quadrat method (7,681; 95% confidence interval: 6,160-9,201), but was more difficult for field survey teams to implement. Although applicable only to similar sites, several general conclusions can be drawn for emergency planning.

  12. Rapid synthesis of single-phase bismuth ferrite by microwave-assisted hydrothermal method

    International Nuclear Information System (INIS)

    Cao, Wenqian; Chen, Zhi; Gao, Tong; Zhou, Dantong; Leng, Xiaonan; Niu, Feng; Zhu, Yuxiang; Qin, Laishun; Wang, Jiangying; Huang, Yuexiang

    2016-01-01

    This paper describes on the fast synthesis of bismuth ferrite by the simple microwave-assisted hydrothermal method. The phase transformation and the preferred growth facets during the synthetic process have been investigated by X-ray diffraction. Bismuth ferrite can be quickly prepared by microwave hydrothermal method by simply controlling the reaction time, which is further confirmed by Fourier Transform infrared spectroscopy and magnetic measurement. - Graphical abstract: Single-phase BiFeO_3 could be realized at a shortest reaction time of 65 min. The reaction time has strong influences on the phase transformation and the preferred growth facets. - Highlights: • Rapid synthesis (65 min) of BiFeO_3 by microwave-assisted hydrothermal method. • Reaction time has influence on the purity and preferred growth facets. • FTIR and magnetic measurement further confirm the pure phase.

  13. Rapid determination method of radiocesium in sea water by cesium-selective resin

    International Nuclear Information System (INIS)

    Nakaoka, A.; Yokoyama, H.; Fukushima, M.; Takagi, S.

    1980-01-01

    A rapid and precise method of determining radiocesium corresponding to 5 mrem/y (the Japan AEC's guideline) was proposed. The development and practical performance of cesium-selective resin and the determination method are described in this paper. The resin was prepared by the formation of ammonium molybdophosphate in the structure of Amberlite XAD-7 resin. It took only 3 hours to carry out all the procedures the authors proposed. This value represents 1/10 to 1/2 of the time of the conventional method. The concentration of 137 Cs and 134 Cs in sea water was determined to be 0.13 to 0.16 pCi/l and less than 7.1x10 -2 pCi/l, respectively. (author)

  14. Rapid detection of human fecal Eubacterium species and related genera by nested PCR method.

    Science.gov (United States)

    Kageyama, A; Benno, Y

    2001-01-01

    PCR procedures based on 16S rDNA gene sequence specific for seven Eubacterium spp. and Eggerthella lenta that predominate in the human intestinal tract were developed, and used for direct detection of these species in seven human feces samples. Three species of Eggerthella lenta, Eubacterium rectale, and Eubacterium eligens were detected from seven fecal samples. Eubacterium biforme was detected from six samples. It was reported that E. rectale, E. eligens, and E. biforme were difficult to detect by traditional culture method, but the nested PCR method is available for the detection of these species. This result shows that the nested PCR method utilizing a universal primer pair, followed by amplification with species-specific primers, would allow rapid detection of Eubacterium species in human feces.

  15. Radiometric and Instrumental Neutron Activation Analysis (INAA) of environmental specimens: lacustrine sediments from Danube Delta

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    specificity analytical methods such as Instrumental Neutron Activation Analysis (INAA) could evidence more than 40 different elements at concentrations about ppm or lower. Unwanted events as atmospheric nuclear tests and Chernobyl accident discharged a great amount of radioactive 137 Cs that once fixed into sediments represents an excellent tracer for natural processes such as sediment transport, accumulation and redistribution during the last 40-50 years. For multielemental investigation of environmental samples such as soil, sediments, water or various minerals INAA is one of the most suitable technique. Presumably pollutants elements such as Cr, Co, Zn, As, Sb and Br as well as REE that could be easily determined by INAA are helpful indicators of the source as well as of the mechanism of deposition and incorporation of these components. Investigated in correlation with radiocesium distribution as well as some natural trace elements such as REE, Sc or Hf, their vertical profiles in sediments allows a rapid reconstruction of the history of recent pollution processes. Radiometric and INAA measurements have been performed 'in tandem' for sediments collected from different lakes located in both Fluvial (western part) and Fluvio-maritime (eastern part and the Razelm-Sinoe lacustrine complex) sections of the Danube Delta, i.e. Lung, Mesteru, Matita, Furtuna and Merhei as well as Razelm and Leahova, respectively. A review of these investigations concerning the vertical profiles of 4 major elements (Na, K, Ca and Fe), 15 trace elements (Rb, Cs, Ba, Sc, La, Ce, Sm, Eu, Tb, Yb, Lu, Th, U, Hf and Ta) as well as of 6 potential pollutants (Zn, Cr, Co, As, Sb and Br) in four lakes (Lung, Furtuna, Mester and Matita) together with anthropogenic 134 Cs and 137 Cs is presented. All these results reveal the great potential of radiometric as well as INAA in environmental as well as in geological investigations. (author)

  16. A method to provide rapid in situ determination of tip radius in dynamic atomic force microscopy

    International Nuclear Information System (INIS)

    Santos, Sergio; Guang Li; Souier, Tewfik; Gadelrab, Karim; Chiesa, Matteo; Thomson, Neil H.

    2012-01-01

    We provide a method to characterize the tip radius of an atomic force microscopy in situ by monitoring the dynamics of the cantilever in ambient conditions. The key concept is that the value of free amplitude for which transitions from the attractive to repulsive force regimes are observed, strongly depends on the curvature of the tip. In practice, the smaller the value of free amplitude required to observe a transition, the sharper the tip. This general behavior is remarkably independent of the properties of the sample and cantilever characteristics and shows the strong dependence of the transitions on the tip radius. The main advantage of this method is rapid in situ characterization. Rapid in situ characterization enables one to continuously monitor the tip size during experiments. Further, we show how to reproducibly shape the tip from a given initial size to any chosen larger size. This approach combined with the in situ tip size monitoring enables quantitative comparison of materials measurements between samples. These methods are set to allow quantitative data acquisition and make direct data comparison readily available in the community.

  17. An evaluation of rapid methods for monitoring vegetation characteristics of wetland bird habitat

    Science.gov (United States)

    Tavernia, Brian G.; Lyons, James E.; Loges, Brian W.; Wilson, Andrew; Collazo, Jaime A.; Runge, Michael C.

    2016-01-01

    Wetland managers benefit from monitoring data of sufficient precision and accuracy to assess wildlife habitat conditions and to evaluate and learn from past management decisions. For large-scale monitoring programs focused on waterbirds (waterfowl, wading birds, secretive marsh birds, and shorebirds), precision and accuracy of habitat measurements must be balanced with fiscal and logistic constraints. We evaluated a set of protocols for rapid, visual estimates of key waterbird habitat characteristics made from the wetland perimeter against estimates from (1) plots sampled within wetlands, and (2) cover maps made from aerial photographs. Estimated percent cover of annuals and perennials using a perimeter-based protocol fell within 10 percent of plot-based estimates, and percent cover estimates for seven vegetation height classes were within 20 % of plot-based estimates. Perimeter-based estimates of total emergent vegetation cover did not differ significantly from cover map estimates. Post-hoc analyses revealed evidence for observer effects in estimates of annual and perennial covers and vegetation height. Median time required to complete perimeter-based methods was less than 7 percent of the time needed for intensive plot-based methods. Our results show that rapid, perimeter-based assessments, which increase sample size and efficiency, provide vegetation estimates comparable to more intensive methods.

  18. Rapid expansion method (REM) for time‐stepping in reverse time migration (RTM)

    KAUST Repository

    Pestana, Reynam C.

    2009-01-01

    We show that the wave equation solution using a conventional finite‐difference scheme, derived commonly by the Taylor series approach, can be derived directly from the rapid expansion method (REM). After some mathematical manipulation we consider an analytical approximation for the Bessel function where we assume that the time step is sufficiently small. From this derivation we find that if we consider only the first two Chebyshev polynomials terms in the rapid expansion method we can obtain the second order time finite‐difference scheme that is frequently used in more conventional finite‐difference implementations. We then show that if we use more terms from the REM we can obtain a more accurate time integration of the wave field. Consequently, we have demonstrated that the REM is more accurate than the usual finite‐difference schemes and it provides a wave equation solution which allows us to march in large time steps without numerical dispersion and is numerically stable. We illustrate the method with post and pre stack migration results.

  19. A Method to Represent Heterogeneous Materials for Rapid Prototyping: The Matryoshka Approach.

    Science.gov (United States)

    Lei, Shuangyan; Frank, Matthew C; Anderson, Donald D; Brown, Thomas D

    The purpose of this paper is to present a new method for representing heterogeneous materials using nested STL shells, based, in particular, on the density distributions of human bones. Nested STL shells, called Matryoshka models, are described, based on their namesake Russian nesting dolls. In this approach, polygonal models, such as STL shells, are "stacked" inside one another to represent different material regions. The Matryoshka model addresses the challenge of representing different densities and different types of bone when reverse engineering from medical images. The Matryoshka model is generated via an iterative process of thresholding the Hounsfield Unit (HU) data using computed tomography (CT), thereby delineating regions of progressively increasing bone density. These nested shells can represent regions starting with the medullary (bone marrow) canal, up through and including the outer surface of the bone. The Matryoshka approach introduced can be used to generate accurate models of heterogeneous materials in an automated fashion, avoiding the challenge of hand-creating an assembly model for input to multi-material additive or subtractive manufacturing. This paper presents a new method for describing heterogeneous materials: in this case, the density distribution in a human bone. The authors show how the Matryoshka model can be used to plan harvesting locations for creating custom rapid allograft bone implants from donor bone. An implementation of a proposed harvesting method is demonstrated, followed by a case study using subtractive rapid prototyping to harvest a bone implant from a human tibia surrogate.

  20. A method for the rapid generation of nonsequential light-response curves of chlorophyll fluorescence.

    Science.gov (United States)

    Serôdio, João; Ezequiel, João; Frommlet, Jörg; Laviale, Martin; Lavaud, Johann

    2013-11-01

    Light-response curves (LCs) of chlorophyll fluorescence are widely used in plant physiology. Most commonly, LCs are generated sequentially, exposing the same sample to a sequence of distinct actinic light intensities. These measurements are not independent, as the response to each new light level is affected by the light exposure history experienced during previous steps of the LC, an issue particularly relevant in the case of the popular rapid light curves. In this work, we demonstrate the proof of concept of a new method for the rapid generation of LCs from nonsequential, temporally independent fluorescence measurements. The method is based on the combined use of sample illumination with digitally controlled, spatially separated beams of actinic light and a fluorescence imaging system. It allows the generation of a whole LC, including a large number of actinic light steps and adequate replication, within the time required for a single measurement (and therefore named "single-pulse light curve"). This method is illustrated for the generation of LCs of photosystem II quantum yield, relative electron transport rate, and nonphotochemical quenching on intact plant leaves exhibiting distinct light responses. This approach makes it also possible to easily characterize the integrated dynamic light response of a sample by combining the measurement of LCs (actinic light intensity is varied while measuring time is fixed) with induction/relaxation kinetics (actinic light intensity is fixed and the response is followed over time), describing both how the response to light varies with time and how the response kinetics varies with light intensity.

  1. A method of rapidly evaluating image quality of NED optical system

    Science.gov (United States)

    Sun, Qi; Qiu, Chuankai; Yang, Huan

    2014-11-01

    In recent years, with the development of technology of micro-display, advanced optics and the software and hardware, near-to-eye display ( NED) optical system will have a wide range of potential applications in the fields of amusement and virtual reality. However, research on the evaluating image quality of this kind optical system is comparatively lagging behind. Although now there are some methods and equipment for evaluation, they can't be applied in commercial production because of their complex operation and inaccuracy. In this paper, an academic method is proposed and a Rapid Evaluation System (RES) is designed to evaluate the image of optical system rapidly and exactly. Firstly, a set of parameters that eyes are sensitive to and also express the quality of system should be extracted and quantized to be criterion, so the evaluation standards can be established. Then, some parameters can be detected by RES consisted of micro-display, CCD camera and computer and so on. By process of scaling, the measuring results of the RES are exact and creditable, relationship between object measurement, subjective evaluation and the RES will be established. After that, image quality of optical system can be evaluated just by detecting parameters of that. The RES is simple and the results of evaluation are exact and keeping with human vision. So the method can be used not only for optimizing design of optical system, but also for evaluation in commercial production.

  2. A rapid method for measuring soil water content in the field with a areometer

    Directory of Open Access Journals (Sweden)

    Calbo Adonai Gimenez

    2002-01-01

    Full Text Available The availability of a rapid method to evaluate the soil water content (U can be an important tool to determine the moment to irrigate. The soil areometer consists of an elongated hydrostatic balance with a weighing pan, a graduated neck, a float and a pynometric flask. In this work an areometer was adapted to rapidly measure soil water content without the need of drying the soil. The expression U = (M A - M AD/(M M -M A was used to calculate the soil water content. In this equation M M is the mass to level the areometer with the pycnometric flask filled with water, M A the mass to level the areometer with a mass M M of soil in the pycnometer, the volume being completed with water, and similarly M AD the mass added to the pan to level the areometer with a mass M M of dried soil in the pycnometric flask. The convenience of this method is that the values M M and M AD are known. Consequently, the decision on irrigation can be made after a measurement that takes, about, ten minutes. The procedure involves only stirring the soil with water for at least 2 minutes to remove the adhered air. The soil water content data obtained with the areometric method were similar to those obtained weighing the soil before and after drying to constant weight, in an oven at 105º C.

  3. A rapid method for the determination on fluoride in geological samples

    International Nuclear Information System (INIS)

    Josephson, M.; Cook, E.B.T.; Dixon, K.

    1977-01-01

    An account is given of a rapid procedure for the determination by use of the specific-ion electrode of fluoride in geological samples. The sample is fused with sodium hydroxide in a nickel crucible in a muffle furnace. The melt is leached with water, a buffer solution of ammonium citrate is added, and the fluoride activity is measured with a specific-ion electrode. All operations are carried out in the crucible, making possible approximately 100 determinations a day. The precision of the method is approximately 10 per cent at a fluoride concentration of 500 p.p.m., which is acceptable for geological-survey work [af

  4. Justification of the averaging method for parabolic equations containing rapidly oscillating terms with large amplitudes

    International Nuclear Information System (INIS)

    Levenshtam, V B

    2006-01-01

    We justify the averaging method for abstract parabolic equations with stationary principal part that contain non-linearities (subordinate to the principal part) some of whose terms are rapidly oscillating in time with zero mean and are proportional to the square root of the frequency of oscillation. Our interest in the exponent 1/2 is motivated by the fact that terms proportional to lower powers of the frequency have no influence on the average. For linear equations of the same type, we justify an algorithm for the study of the stability of solutions in the case when the stationary averaged problem has eigenvalues on the imaginary axis (the critical case)

  5. Flow method for rapid production of Batio3 nanoparticles in supercritical water

    International Nuclear Information System (INIS)

    Atashfaraz, M.; Shariati-Niassar, M.; Ohara, Satoshi; Takami, S.; Umetsu, M.; Naka, T.; Adschiri, T.

    2006-01-01

    Fine BaTiO 3 nanoparticles were obtained by hydrothermal synthesis under supercritical conditions with batch and flow type experimental methods. Mixture of barium hydroxide and titanium oxide starting solution was treated in the supercritical wafer at 400 d eg C and 30 MPa. The size of nanoparticles synthesized in the flow type experiment was smaller than that in the batch type. Rapid heating in a flow, reactor is effective to synthesize smaller size and narrower particle size distribution for the BaTiO 3 , nanoparticles. The mechanism for this result was discussed based on the solubility of titanium oxide

  6. Rapid and accurate processing method for amide proton exchange rate measurement in proteins

    International Nuclear Information System (INIS)

    Koskela, Harri; Heikkinen, Outi; Kilpelaeinen, Ilkka; Heikkinen, Sami

    2007-01-01

    Exchange between protein backbone amide hydrogen and water gives relevant information about solvent accessibility and protein secondary structure stability. NMR spectroscopy provides a convenient tool to study these dynamic processes with saturation transfer experiments. Processing of this type of NMR spectra has traditionally required peak integration followed by exponential fitting, which can be tedious with large data sets. We propose here a computer-aided method that applies inverse Laplace transform in the exchange rate measurement. With this approach, the determination of exchange rates can be automated, and reliable results can be acquired rapidly without a need for manual processing

  7. Three rapid methods for determination {sup 90}Sr in milk samples using liquid scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Abbasisiara, F.; Attarilar, N. [Iranian Nuclear Regulatory Authority (INRA), Atomic Energy Organization of Iran (AEOI), Environmental Radiation Protection Div., National Radiation Protection Dept. (Iran, Islamic Republic of); Afshar, N. [Tarbiat Modarres Univ. (Iran, Islamic Republic of)

    2006-07-01

    Strontium radionuclide {sup 90}Sr is one of the main long-lived components of the radioactive fallout which occurred as a result of previous atmospheric nuclear tests and also nuclear accidents such as Chernobyl accident. Due to chemical and biochemical similarities between strontium and calcium, more than 99% of strontium is efficiently incorporated into bone tissue and teeth and Characterized by along physical and biological half-life, it may cause damage to bone marrow. Since determination of this radionuclide often is a time consuming process, rapid determination methods specially in emergency situations is always desirable. In this work, three rapid methods for determination of this radionuclide in milk samples will be evaluated. All of the methods include two major steps: 1- strontium separation from fats and proteins which can be performed by drying (in case of the fresh milk samples), ashing and leaching by nitric acids or by using exchange or chelating resins which have strong affinity for alkaline earth cations such as Dowex 50W-X8. And 2- Separation of Sr-90 or its daughter product, Y-90. In two methods separation of {sup 90}Sr is performed by extraction of the daughter nuclide, {sup 90}Y, by aid of organic extracting agent, Tributylphosphate or T.B.P., and then Cherenkov counting of the Y-90 extracted. The third method is based on separation of this radionuclide using Crown Ether or Sr -Spec resin. The detailed radiochemical procedures and evaluation of each method advantages or disadvantages will explained in full text paper. (authors)

  8. A rapid and cost-effective fluorescence detection in tube (FDIT) method to analyze protein phosphorylation.

    Science.gov (United States)

    Jin, Xiao; Gou, Jin-Ying

    2016-01-01

    Protein phosphorylation is one of the most important post-translational modifications catalyzed by protein kinases in living organisms. The advance of genome sequencing provided the information of protein kinase families in many organisms, including both model and non-model plants. The development of proteomics technologies also enabled scientists to efficiently reveal a large number of protein phosphorylations of an organism. However, kinases and phosphorylation targets are still to be connected to illustrate the complicated network in life. Here we adapted Pro-Q ® Diamond (Pro-Q ® Diamond Phosphoprotein Gel Stain), a widely used phosphoprotein gel-staining fluorescence dye, to establish a rapid, economical and non-radioactive fluorescence detection in tube (FDIT) method to analyze phosphorylated proteins. Taking advantages of high sensitivity and specificity of Pro-Q ® diamond, the FDIT method is also demonstrated to be rapid and reliable, with a suitable linear range for in vitro protein phosphorylation. A significant and satisfactory protein kinase reaction was detected as fast as 15 min from Wheat Kinase START 1.1 (WKS1.1) on a thylakoid ascorbate peroxidase (tAPX), an established phosphorylation target in our earlier study. The FDIT method saves up to 95% of the dye consumed in a gel staining method. The FDIT method is remarkably quick, highly reproducible, unambiguous and capable to be scaled up to dozens of samples. The FDIT method could serve as a simple and sensitive alternative procedure to determine protein kinase reactions with zero radiation exposure, as a supplementation to other widely used radioactive and in-gel assays.

  9. A rapid and cost-effective fluorescence detection in tube (FDIT method to analyze protein phosphorylation

    Directory of Open Access Journals (Sweden)

    Xiao Jin

    2016-11-01

    Full Text Available Abstract Background Protein phosphorylation is one of the most important post-translational modifications catalyzed by protein kinases in living organisms. The advance of genome sequencing provided the information of protein kinase families in many organisms, including both model and non-model plants. The development of proteomics technologies also enabled scientists to efficiently reveal a large number of protein phosphorylations of an organism. However, kinases and phosphorylation targets are still to be connected to illustrate the complicated network in life. Results Here we adapted Pro-Q® Diamond (Pro-Q® Diamond Phosphoprotein Gel Stain, a widely used phosphoprotein gel-staining fluorescence dye, to establish a rapid, economical and non-radioactive fluorescence detection in tube (FDIT method to analyze phosphorylated proteins. Taking advantages of high sensitivity and specificity of Pro-Q® diamond, the FDIT method is also demonstrated to be rapid and reliable, with a suitable linear range for in vitro protein phosphorylation. A significant and satisfactory protein kinase reaction was detected as fast as 15 min from Wheat Kinase START 1.1 (WKS1.1 on a thylakoid ascorbate peroxidase (tAPX, an established phosphorylation target in our earlier study. Conclusion The FDIT method saves up to 95% of the dye consumed in a gel staining method. The FDIT method is remarkably quick, highly reproducible, unambiguous and capable to be scaled up to dozens of samples. The FDIT method could serve as a simple and sensitive alternative procedure to determine protein kinase reactions with zero radiation exposure, as a supplementation to other widely used radioactive and in-gel assays.

  10. a Method for Preview Vibration Control of Systems Having Forcing Inputs and Rapidly-Switched Dampers

    Science.gov (United States)

    ElBeheiry, E. M.

    1998-07-01

    In a variety of applications, especially in large scale dynamic systems, the mechanization of different vibration control elements in different locations would be decided by limitations placed on the modal vibration of the system and the inherent dynamic coupling between its modes. Also, the quality of vibration control to the economy of producing the whole system would be another trade-off leading to a mix of passive, active and semi-active vibration control elements in one system. This termactiveis limited to externally powered vibration control inputs and the termsemi-activeis limited to rapidly switched dampers. In this article, an optimal preview control method is developed for application to dynamic systems having active and semi-active vibration control elements mechanized at different locations in one system. The system is then a piecewise (bilinear) controller in which two independent sets of control inputs appear additively and multiplicatively. Calculus of variations along with the Hamiltonian approach are employed for the derivation of this method. In essence, it requires the active elements to be ideal force generators and the switched dampers to have the property of on-line variation of the damping characteristics to pre-determined limits. As the dampers switch during operation the whole system's structure differs, and then values of the active forcing inputs are adapted to match these rapid changes. Strictly speaking, each rapidly switched damper has pre-known upper and lower damping levels and it can take on any in-between value. This in-between value is to be determined by the method as long as the damper tracks a pre-known fully active control demand. In every damping state of each semi-active damper the method provides the optimal matching values of the active forcing inputs. The method is shown to have the feature of solving simple standard matrix equations to obtain closed form solutions. A comprehensive 9-DOF tractor semi-trailer model is used

  11. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue.

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-10

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  12. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-01

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  13. A Rapid Method for Determining the Concentration of Recombinant Protein Secreted from Pichia pastoris

    International Nuclear Information System (INIS)

    Sun, L W; Zhao, Y; Jiang, R; Song, Y; Feng, H; Feng, K; Niu, L P; Qi, C

    2011-01-01

    Pichia secretive expression system is one of powerful eukaryotic expression systems in genetic engineering, which is especially suitable for industrial utilization. Because of the low concentration of the target protein in initial experiment, the methods and conditions for expression of the target protein should be optimized according to the protein yield repetitively. It is necessary to set up a rapid, simple and convenient analysis method for protein expression levels instead of the generally used method such as ultrafiltration, purification, dialysis, lyophilization and so on. In this paper, acetone precipitation method was chosen to concentrate the recombinant protein firstly after comparing with four different protein precipitation methods systematically, and then the protein was analyzed by SDS-Polyacrylamide Gel Electrophoresis. The recombinant protein was determined with the feature of protein band by the Automated Image Capture and 1-D Analysis Software directly. With this method, the optimized expression conditions of basic fibroblast growth factor secreted from pichia were obtained, which is as the same as using traditional methods. Hence, a convenient tool to determine the optimized conditions for the expression of recombinant proteins in Pichia was established.

  14. A rapid chemical method for lysing Arabidopsis cells for protein analysis

    Directory of Open Access Journals (Sweden)

    Takano Tetsuo

    2011-07-01

    Full Text Available Abstract Background Protein extraction is a frequent procedure in biological research. For preparation of plant cell extracts, plant materials usually have to be ground and homogenized to physically break the robust cell wall, but this step is laborious and time-consuming when a large number of samples are handled at once. Results We developed a chemical method for lysing Arabidopsis cells without grinding. In this method, plants are boiled for just 10 minutes in a solution containing a Ca2+ chelator and detergent. Cell extracts prepared by this method were suitable for SDS-PAGE and immunoblot analysis. This method was also applicable to genomic DNA extraction for PCR analysis. Our method was applied to many other plant species, and worked well for some of them. Conclusions Our method is rapid and economical, and allows many samples to be prepared simultaneously for protein analysis. Our method is useful not only for Arabidopsis research but also research on certain other species.

  15. Relative Radiometric Normalization and Atmospheric Correction of a SPOT 5 Time Series

    Directory of Open Access Journals (Sweden)

    Matthieu Rumeau

    2008-04-01

    Full Text Available Multi-temporal images acquired at high spatial and temporal resolution are an important tool for detecting change and analyzing trends, especially in agricultural applications. However, to insure a reliable use of this kind of data, a rigorous radiometric normalization step is required. Normalization can be addressed by performing an atmospheric correction of each image in the time series. The main problem is the difficulty of obtaining an atmospheric characterization at a given acquisition date. In this paper, we investigate whether relative radiometric normalization can substitute for atmospheric correction. We develop an automatic method for relative radiometric normalization based on calculating linear regressions between unnormalized and reference images. Regressions are obtained using the reflectances of automatically selected invariant targets. We compare this method with an atmospheric correction method that uses the 6S model. The performances of both methods are compared using 18 images from of a SPOT 5 time series acquired over Reunion Island. Results obtained for a set of manually selected invariant targets show excellent agreement between the two methods in all spectral bands: values of the coefficient of determination (r² exceed 0.960, and bias magnitude values are less than 2.65. There is also a strong correlation between normalized NDVI values of sugarcane fields (r² = 0.959. Despite a relative error of 12.66% between values, very comparable NDVI patterns are observed.

  16. Optimal estimation and scheduling in aquifer management using the rapid feedback control method

    Science.gov (United States)

    Ghorbanidehno, Hojat; Kokkinaki, Amalia; Kitanidis, Peter K.; Darve, Eric

    2017-12-01

    Management of water resources systems often involves a large number of parameters, as in the case of large, spatially heterogeneous aquifers, and a large number of "noisy" observations, as in the case of pressure observation in wells. Optimizing the operation of such systems requires both searching among many possible solutions and utilizing new information as it becomes available. However, the computational cost of this task increases rapidly with the size of the problem to the extent that textbook optimization methods are practically impossible to apply. In this paper, we present a new computationally efficient technique as a practical alternative for optimally operating large-scale dynamical systems. The proposed method, which we term Rapid Feedback Controller (RFC), provides a practical approach for combined monitoring, parameter estimation, uncertainty quantification, and optimal control for linear and nonlinear systems with a quadratic cost function. For illustration, we consider the case of a weakly nonlinear uncertain dynamical system with a quadratic objective function, specifically a two-dimensional heterogeneous aquifer management problem. To validate our method, we compare our results with the linear quadratic Gaussian (LQG) method, which is the basic approach for feedback control. We show that the computational cost of the RFC scales only linearly with the number of unknowns, a great improvement compared to the basic LQG control with a computational cost that scales quadratically. We demonstrate that the RFC method can obtain the optimal control values at a greatly reduced computational cost compared to the conventional LQG algorithm with small and controllable losses in the accuracy of the state and parameter estimation.

  17. A rapid cleanup method for the isolation and concentration of pyrrolizidine alkaloids in comfrey root.

    Science.gov (United States)

    Gray, Dean E; Porter, Andrew; O'Neill, Terry; Harris, Roger K; Rottinghaus, George E

    2004-01-01

    Preparations from comfrey (Symphytum officinale and S. x uplandicum) root and leaf contain varying levels of the hepatotoxic pyrrolizidine alkaloids (PAs). Reference compounds for comfrey are not commercially available, and there is currently no rapid extraction or analytical method capable of determining low levels in raw materials or as adulterants in commercially available extracts. A solid-phase extraction (SPE) method was developed using an Ergosil cleanup column that specifically binds the PAs. With this method, powdered comfrey root was extracted by sonication and shaking with basic chloroform. The extract was applied to the cleanup column under vacuum, washed with 2 mL acetone-chloroform (8 + 2, v/v) followed by 2 mL petroleum ether to remove excess chloroform. The column was dried under vacuum, and the PAs were eluted with 2 successive 1 mL aliquots methanol. Percent recoveries of the PAs following Ergosil SPE had an overall average of 96.8%, with RSD of 3.8% over a range of 1.0 to 25.0 g extracted in 100 mL. Average precision of the method (n = 3 over 4 extraction concentrations) gave an overall RSD of 6.0% for the 5 alkaloids, with a range of 0.8% (5 g in 100 mL) to 11.2% (25 g in 100 mL). Recovery optimization testing showed that 1.0 g comfrey root extracted in 100 mL yielded the greatest recovery (% dry weight) of the PAs, with an extraction efficiency and accuracy of 94.2%, and RSD of 1.7% (n = 9). The unique properties of the Ergosil cleanup column provide rapid sample cleanup, volume reduction, and concentration of PAs from comfrey extracts, and allow the eluant to be analyzed directly by traditional chromatographic methods.

  18. Evaluation of PDA Technical Report No 33. Statistical Testing Recommendations for a Rapid Microbiological Method Case Study.

    Science.gov (United States)

    Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David

    2015-01-01

    New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc

  19. A rapid colorimetric method for predicting the storage stability of middle distillate fuels

    Energy Technology Data Exchange (ETDEWEB)

    Marshman, S.J. [Defense Research Agency, Surrey (United Kingdom)

    1995-05-01

    Present methods used to predict the storage stability of distillate fuels such as ASTM D2274, ASTM D4625, DEF STAN 05-50 Method 40 and in-house methods are very time consuming, taking a minimum of 16 hours. In addition, some of these methods under- or over-predict the storage stability of the test fuel. A rapid colorimetric test for identifying cracked, straight run or hydrofined fuels was reported at the previous Conference. Further work has shown that while a visual appraisal is acceptable for refinery-fresh fuels, colour development may be masked by other coloured compounds in older fuels. Use of a spectrometric finish to the method has extended the scope of the method to include older fuels. The test can be correlated with total sediment from ASTM D4625 (13 weeks at 43{degrees}C) over a sediment range of 0-60mg/L. A correlation of 0.94 was obtained for 40 fuels.

  20. Developing the RIAM method (rapid impact assessment matrix) in the context of impact significance assessment

    International Nuclear Information System (INIS)

    Ijaes, Asko; Kuitunen, Markku T.; Jalava, Kimmo

    2010-01-01

    In this paper the applicability of the RIAM method (rapid impact assessment matrix) is evaluated in the context of impact significance assessment. The methodological issues considered in the study are: 1) to test the possibilities of enlarging the scoring system used in the method, and 2) to compare the significance classifications of RIAM and unaided decision-making to estimate the consistency between these methods. The data used consisted of projects for which funding had been applied for via the European Union's Regional Development Trust in the area of Central Finland. Cases were evaluated with respect to their environmental, social and economic impacts using an assessment panel. The results showed the scoring framework used in RIAM could be modified according to the problem situation at hand, which enhances its application potential. However the changes made in criteria B did not significantly affect the final ratings of the method, which indicates the high importance of criteria A1 (importance) and A2 (magnitude) to the overall results. The significance classes obtained by the two methods diverged notably. In general the ratings given by RIAM tended to be smaller compared to intuitive judgement implying that the RIAM method may be somewhat conservative in character.

  1. A new method for rapid determination of carbohydrate and total carbon concentrations using UV spectrophotometry.

    Science.gov (United States)

    Albalasmeh, Ammar A; Berhe, Asmeret Asefaw; Ghezzehei, Teamrat A

    2013-09-12

    A new UV spectrophotometry based method for determining the concentration and carbon content of carbohydrate solution was developed. This method depends on the inherent UV absorption potential of hydrolysis byproducts of carbohydrates formed by reaction with concentrated sulfuric acid (furfural derivatives). The proposed method is a major improvement over the widely used Phenol-Sulfuric Acid method developed by DuBois, Gilles, Hamilton, Rebers, and Smith (1956). In the old method, furfural is allowed to develop color by reaction with phenol and its concentration is detected by visible light absorption. Here we present a method that eliminates the coloration step and avoids the health and environmental hazards associated with phenol use. In addition, avoidance of this step was shown to improve measurement accuracy while significantly reducing waiting time prior to light absorption reading. The carbohydrates for which concentrations and carbon content can be reliably estimated with this new rapid Sulfuric Acid-UV technique include: monosaccharides, disaccharides and polysaccharides with very high molecular weight. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Application of two electrical methods for the rapid assessment of freezing resistance in Salix epichloro

    Energy Technology Data Exchange (ETDEWEB)

    Tsarouhas, V.; Kenney, W.A.; Zsuffa, L. [University of Toronto, Ontario (Canada). Faculty of Forestry

    2000-09-01

    The importance of early selection of frost-resistant Salix clones makes it desirable to select a rapid and accurate screening method for assessing freezing resistance among several genotypes. Two electrical methods, stem electrical impedance to 1 and 10 khz alternating current, and electrolyte leakage of leaf tissue, were evaluated for detecting freezing resistance on three North America Salix epichloro Michx., clones after subjecting them to five different freezing temperatures (-1, -2, -3, -4, and -5 deg C). Differences in the electrical impedance to 1 and 10 kHz, and the ratio of the impedance at the two frequencies (low/high) before and after the freezing treatment (DZ{sub low}, DZ{sub high}, and DZ{sub ratio}, respectively) were estimated. Electrolyte leakage was expressed as relative conductivity (RC{sub t}) and index of injury (IDX{sub t}). Results from the two methods, obtained two days after the freezing stress, showed that both electrical methods were able to detect freezing injury in S. eriocephala. However, the electrolyte leakage method detected injury in more levels of freezing stress (-3, -4, and -5 deg C) than the impedance (-4, and -5 deg C), it assessed clonal differences in S. eriocephala freezing resistance, and it was best suited to correlate electrical methods with the visual assessed freezing injury. No significant impedance or leakage changes were found after the -1 and -2 deg C freezing temperatures. (author)

  3. Efficient 3D frequency response modeling with spectral accuracy by the rapid expansion method

    KAUST Repository

    Chu, Chunlei

    2012-07-01

    Frequency responses of seismic wave propagation can be obtained either by directly solving the frequency domain wave equations or by transforming the time domain wavefields using the Fourier transform. The former approach requires solving systems of linear equations, which becomes progressively difficult to tackle for larger scale models and for higher frequency components. On the contrary, the latter approach can be efficiently implemented using explicit time integration methods in conjunction with running summations as the computation progresses. Commonly used explicit time integration methods correspond to the truncated Taylor series approximations that can cause significant errors for large time steps. The rapid expansion method (REM) uses the Chebyshev expansion and offers an optimal solution to the second-order-in-time wave equations. When applying the Fourier transform to the time domain wavefield solution computed by the REM, we can derive a frequency response modeling formula that has the same form as the original time domain REM equation but with different summation coefficients. In particular, the summation coefficients for the frequency response modeling formula corresponds to the Fourier transform of those for the time domain modeling equation. As a result, we can directly compute frequency responses from the Chebyshev expansion polynomials rather than the time domain wavefield snapshots as do other time domain frequency response modeling methods. When combined with the pseudospectral method in space, this new frequency response modeling method can produce spectrally accurate results with high efficiency. © 2012 Society of Exploration Geophysicists.

  4. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    Science.gov (United States)

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Development of a qPCR method to rapidly assess the function of NKT cells.

    Science.gov (United States)

    Sohn, Silke; Tiper, Irina; Japp, Emily; Sun, Wenji; Tkaczuk, Katherine; Webb, Tonya J

    2014-05-01

    NKT cells comprise a rare, but important subset of T cells which account for ~0.2% of the total circulating T cell population. NKT cells are known to have anti-tumor functions and rapidly produce high levels of cytokines following activation. Several clinical trials have sought to exploit the effector functions of NKT cells. While some studies have shown promise, NKT cells are approximately 50% lower in cancer patients compared to healthy donors of the same age and gender, thus limiting their therapeutic efficacy. These studies indicate that baseline levels of activation should be assessed before initiating an NKT cell based immunotherapeutic strategy. The goal of this study was to develop a sensitive method to rapidly assess NKT cell function. We utilized artificial antigen presenting cells in combination with qPCR in order to determine NKT cell function in peripheral blood mononuclear cells from healthy donors and breast cancer patients. We found that NKT cell activation can be detected by qPCR, but not by ELISA, in healthy donors as well as in breast cancer patients following four hour stimulation. This method utilizing CD1d-expressing aAPCs will enhance our knowledge of NKT cell biology and could potentially be used as a novel tool in adoptive immunotherapeutic strategies. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. High resolution melting analysis: a rapid and accurate method to detect CALR mutations.

    Directory of Open Access Journals (Sweden)

    Cristina Bilbao-Sieyro

    Full Text Available The recent discovery of CALR mutations in essential thrombocythemia (ET and primary myelofibrosis (PMF patients without JAK2/MPL mutations has emerged as a relevant finding for the molecular diagnosis of these myeloproliferative neoplasms (MPN. We tested the feasibility of high-resolution melting (HRM as a screening method for rapid detection of CALR mutations.CALR was studied in wild-type JAK2/MPL patients including 34 ET, 21 persistent thrombocytosis suggestive of MPN and 98 suspected secondary thrombocytosis. CALR mutation analysis was performed through HRM and Sanger sequencing. We compared clinical features of CALR-mutated versus 45 JAK2/MPL-mutated subjects in ET.Nineteen samples showed distinct HRM patterns from wild-type. Of them, 18 were mutations and one a polymorphism as confirmed by direct sequencing. CALR mutations were present in 44% of ET (15/34, 14% of persistent thrombocytosis suggestive of MPN (3/21 and none of the secondary thrombocytosis (0/98. Of the 18 mutants, 9 were 52 bp deletions, 8 were 5 bp insertions and other was a complex mutation with insertion/deletion. No mutations were found after sequencing analysis of 45 samples displaying wild-type HRM curves. HRM technique was reproducible, no false positive or negative were detected and the limit of detection was of 3%.This study establishes a sensitive, reliable and rapid HRM method to screen for the presence of CALR mutations.

  7. Rapid fabrication method of a microneedle mold with controllable needle height and width.

    Science.gov (United States)

    Lin, Yen-Heng; Lee, I-Chi; Hsu, Wei-Chieh; Hsu, Ching-Hong; Chang, Kai-Ping; Gao, Shao-Syuan

    2016-10-01

    The main issue of transdermal drug delivery is that macromolecular drugs cannot diffuse through the stratum corneum of skin. Many studies have pursued micro-sized needles encapsulated with drugs to overcome this problem, as these needles can pierce the stratum corneum and allow drugs to enter the circulatory system of the human body. However, most microneedle fabrication processes are time-consuming and require expensive equipment. In this study, we demonstrate a rapid method for fabricating a microneedle mold using drawing lithography and a UV-cured resin. The mold was filled with a water-soluble material, polyvinylpyrrolidone (PVP), which was then demolded to produce a water-soluble microneedle array. The results of an in vitro skin insertion test using PVP microneedles and pig ear skin demonstrated the feasibility of the microneedle mold. In addition, by controlling the viscosity of the UV-cured resin through various heat treatments, microneedles with different heights and aspect ratios were produced. Compared with other methods, this technology significantly simplifies and accelerates the mold fabrication process. In addition, the required equipment is relatively simple and inexpensive. Through this technology, we can rapidly fabricate microneedle molds with controllable dimensions for various applications.

  8. A rapid method for the preparation of 99Tcm hexametazime-labelled leucocytes

    International Nuclear Information System (INIS)

    Solanki, K.K.; Mather, S.J.; Janabi, M.A.; Britton, K.E.

    1988-01-01

    99 Tc m (±)-hexamethylpropyleneamineoxime (HMPAO) ( 99 Tc m Hexametazime) has been recently reported as an alternative for labelling leucocytes. This technique has been modified to give a simpler routine in-house labelling technique. It has three advantages: only about 20 ml of blood is required, the labelling time is just under 1 h and high yields of labelled leucocytes are obtained (mean of 500 MBq per injection dose). The properties of labelled leucocytes using this modified method are; 80% granulocyte-bound radioactivity, a rapid lung transit and a blood granulocyte recovery of 40% at 30 min similar to those described previously. The viability of the labelled leucocytes was tested and confirmed in vitro using a migration technique and in vivo by showing no lung retention on early imaging and high splenic uptake. A rapid in-process chromatography assessment procedure for regulating the protocol has been developed. Successful abscess imaging by 4 h has been achieved in 21 patients with normal results in another 22 patients without abscesses. This simpler method should encourage a more widespread application of scintigraphy using radiolabelled granulocytes. (author)

  9. A rapid, ensemble and free energy based method for engineering protein stabilities.

    Science.gov (United States)

    Naganathan, Athi N

    2013-05-02

    Engineering the conformational stabilities of proteins through mutations has immense potential in biotechnological applications. It is, however, an inherently challenging problem given the weak noncovalent nature of the stabilizing interactions. In this regard, we present here a robust and fast strategy to engineer protein stabilities through mutations involving charged residues using a structure-based statistical mechanical model that accounts for the ensemble nature of folding. We validate the method by predicting the absolute changes in stability for 138 experimental mutations from 16 different proteins and enzymes with a correlation of 0.65 and importantly with a success rate of 81%. Multiple point mutants are predicted with a higher success rate (90%) that is validated further by comparing meosphile-thermophile protein pairs. In parallel, we devise a methodology to rapidly engineer mutations in silico which we benchmark against experimental mutations of ubiquitin (correlation of 0.95) and check for its feasibility on a larger therapeutic protein DNase I. We expect the method to be of importance as a first and rapid step to screen for protein mutants with specific stability in the biotechnology industry, in the construction of stability maps at the residue level (i.e., hot spots), and as a robust tool to probe for mutations that enhance the stability of protein-based drugs.

  10. Rapid and label-free bioanalytical method of alpha fetoprotein detection using LSPR chip

    Science.gov (United States)

    Kim, Dongjoo; Kim, Jinwoon; Kwak, Cheol Hwan; Heo, Nam Su; Oh, Seo Yeong; Lee, Hoomin; Lee, Go-Woon; Vilian, A. T. Ezhil; Han, Young-Kyu; Kim, Woo-Sik; Kim, Gi-bum; Kwon, Soonjo; Huh, Yun Suk

    2017-07-01

    Alpha fetoprotein (AFP) is a cancer marker, particularly for hepatocellular carcinoma. Normal levels of AFP are less than 20 ng/mL; however, its levels can reach more than 400 ng/mL in patients with HCC. Enzyme linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) have been employed for clinical diagnosis of AFP; however, these methods are time consuming and labor intensive. In this study, we developed a localized surface plasmon resonance (LSPR) based biosensor for simple and rapid detection of AFP. This biosensor consists of a UV-Vis spectrometer, a cuvette cell, and a biosensor chip nanopatterned with gold nanoparticles (AuNPs). In our LSPR biosensor, binding of AFP to the surface of the sensor chip led to an increasing magnitude of the LSPR signals, which was measured by an ultraviolet-visible (UV-Vis) spectrometer. Our LSPR biosensor showed sufficient detectability of AFP at concentrations of 1 ng/mL to 1 μg/mL. Moreover, the overall procedure for detection of AFP was completed within 20 min. This biosensor could also be utilized for a point of care test (POCT) by employing a portable UV-Vis spectrometer. Owing to the simplicity and rapidity of the detection process, our LSPR biosensor is expected to replace traditional diagnostic methods for the early detection of diseases.

  11. Development of a novel and simple method to evaluate disintegration of rapidly disintegrating tablets.

    Science.gov (United States)

    Hoashi, Yohei; Tozuka, Yuichi; Takeuchi, Hirofumi

    2013-01-01

    The purpose of this study was to develop and test a novel and simple method for evaluating the disintegration time of rapidly disintegrating tablets (RDTs) in vitro, since the conventional disintegration test described in the pharmacopoeia produces poor results due to the difference of its environmental conditions from those of an actual oral cavity. Six RDTs prepared in our laboratory and 5 types of commercial RDTs were used as model formulations. Using our original apparatus, a good correlation was observed between in vivo and in vitro disintegration times by adjusting the height from which the solution was dropped to 8 cm and the weight of the load to 10 or 20 g. Properties of RDTs, such as the pattern of their disintegrating process, can be assessed by verifying the load. These findings confirmed that our proposed method for an in vitro disintegration test apparatus is an excellent one for estimating disintegration time and the disintegration profile of RDTs.

  12. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent...... of the 92 measurements obtained with the hypocount B were within +/- 20% of the laboratory glucose values. Using haemo-glucotest 1-44 strips, 74% of the readings were within +/- 20% of the reference laboratory values. For values below 5.5 mmol/l, there was a tendency for results to be too low, with 77......% of the readings below laboratory values -20%. All situations with severe hypoglycaemia were detected with both strips. The study also demonstrates the ineffectiveness of s.c. insulin regimens during surgery. Only 47% of the measured blood glucose values were within the range of 5.5-10 mmol/l and two of ten...

  13. A Rapid Colorimetric Method Reveals Fraudulent Substitutions in Sea Urchin Roe Marketed in Sardinia (Italy).

    Science.gov (United States)

    Meloni, Domenico; Spina, Antonio; Satta, Gianluca; Chessa, Vittorio

    2016-06-25

    In recent years, besides the consumption of fresh sea urchin specimens, the demand of minimally-processed roe has grown considerably. This product has made frequent consumption in restaurants possible and frauds are becoming widespread with the partial replacement of sea urchin roe with surrogates that are similar in colour. One of the main factors that determines the quality of the roe is its colour and small differences in colour scale cannot be easily discerned by the consumers. In this study we have applied a rapid colorimetric method for reveal the fraudulent partial substitution of semi-solid sea urchin roe with liquid egg yolk. Objective assessment of whiteness (L*), redness (a*), yellowness (b*), hue (h*), and chroma (C*) was carried out with a digital spectrophotometer using the CIE L*a*b* colour measurement system. The colorimetric method highlighted statistically significant differences among sea urchin roe and liquid egg yolk that could be easily discerned quantitatively.

  14. A Rapid Generation Method of Character Doll with Rotatable Limbs Oriented to 3D Printer

    Institute of Scientific and Technical Information of China (English)

    LI Lin; CHU Xiao-li; Nie Wen-chao

    2014-01-01

    Currently, 3D printing of the character dolls is a very practical application for the average person. But the model of doll which can be obtained is static so the posture of the doll is single. On the other hand, the modification of the model is very difficult to non-professions. This paper proposes an rapid generation method of character doll with rotatable limbs, which is through adding the sphere joint to the doll’s model automatically. After the model is segmented by drawing a line interactively, the sphere joint is created based on the segmentation boundary through entity modeling method. Lastly the two models of the doll and the joint are composited and printed. Some doll’s model are tested on the FDM(Fused Deposition Modeling) 3D printer using this process. The results are more interesting and the efficiency has been greatly improved compared with modifying the model manually.

  15. Rapid synthesis of nitrogen doped titania with mixed crystal lattice via microwave-assisted hydrothermal method

    International Nuclear Information System (INIS)

    Zhang Peilin; Liu Bin; Yin Shu; Wang Yuhua; Petrykin, Valery; Kakihana, Masato; Sato, Tsugio

    2009-01-01

    A microwave-assisted hydrothermal method was employed to synthesize nitrogen doped titania nanoparticles. Due to the high heating efficiency of microwave, rapid synthesis could be achieved in comparison with the conventional oven. Mixed crystal lattice was found existing in the obtained product, and the phase transformation behaviour under calcination was studied by XRD measurement together with Raman spectroscopy in details. The obtained nitrogen doped titania showed high specific surface area, about 300 m 2 g -1 . Photocatalytic activity in destructing NO x gas by the prepared sample exceeded that of commercial titania (P 25) or nitrogen doped titania synthesized by conventional hydrothermal method, under both visible-light and ultraviolet-light irradiation.

  16. Rapid analysis of fertilizers by the direct-reading thermometric method.

    Science.gov (United States)

    Sajó, I; Sipos, B

    1972-05-01

    The authors have developed rapid methods for the determination of the main components of fertilizers, namely phosphate, potassium and nitrogen fixed in various forms. In the absence of magnesium ions phosphate is precipitated with magnesia mixture; in the presence of magnesium ions ammonium phosphomolybdate is precipitated and the excess of molybdate is reacted with hydrogen peroxide. Potassium is determined by precipitation with silico-fluoride. For nitrogen fixed as ammonium salts the ammonium ions are condensed in a basic solution with formalin to hexamethylenetetramine; for nitrogen fixed as carbamide the latter is decomposed with sodium nitrite; for nitrogen fixed as nitrate the latter is reduced with titanium(III). In each case the temperature change of the test solution is measured. Practically all essential components of fertilizers may be determined by direct-reading thermometry; with this method and special apparatus the time of analysis is reduced to at most about 15 min for any determination.

  17. kCCA Transformation-Based Radiometric Normalization of Multi-Temporal Satellite Images

    Directory of Open Access Journals (Sweden)

    Yang Bai

    2018-03-01

    Full Text Available Radiation normalization is an essential pre-processing step for generating high-quality satellite sequence images. However, most radiometric normalization methods are linear, and they cannot eliminate the regular nonlinear spectral differences. Here we introduce the well-established kernel canonical correlation analysis (kCCA into radiometric normalization for the first time to overcome this problem, which leads to a new kernel method. It can maximally reduce the image differences among multi-temporal images regardless of the imaging conditions and the reflectivity difference. It also perfectly eliminates the impact of nonlinear changes caused by seasonal variation of natural objects. Comparisons with the multivariate alteration detection (CCA-based normalization and the histogram matching, on Gaofen-1 (GF-1 data, indicate that the kCCA-based normalization can preserve more similarity and better correlation between an image-pair and effectively avoid the color error propagation. The proposed method not only builds the common scale or reference to make the radiometric consistency among GF-1 image sequences, but also highlights the interesting spectral changes while eliminates less interesting spectral changes. Our method enables the application of GF-1 data for change detection, land-use, land-cover change detection etc.

  18. Radiometric Correction of Multitemporal Hyperspectral Uas Image Mosaics of Seedling Stands

    Science.gov (United States)

    Markelin, L.; Honkavaara, E.; Näsi, R.; Viljanen, N.; Rosnell, T.; Hakala, T.; Vastaranta, M.; Koivisto, T.; Holopainen, M.

    2017-10-01

    Novel miniaturized multi- and hyperspectral imaging sensors on board of unmanned aerial vehicles have recently shown great potential in various environmental monitoring and measuring tasks such as precision agriculture and forest management. These systems can be used to collect dense 3D point clouds and spectral information over small areas such as single forest stands or sample plots. Accurate radiometric processing and atmospheric correction is required when data sets from different dates and sensors, collected in varying illumination conditions, are combined. Performance of novel radiometric block adjustment method, developed at Finnish Geospatial Research Institute, is evaluated with multitemporal hyperspectral data set of seedling stands collected during spring and summer 2016. Illumination conditions during campaigns varied from bright to overcast. We use two different methods to produce homogenous image mosaics and hyperspectral point clouds: image-wise relative correction and image-wise relative correction with BRDF. Radiometric datasets are converted to reflectance using reference panels and changes in reflectance spectra is analysed. Tested methods improved image mosaic homogeneity by 5 % to 25 %. Results show that the evaluated method can produce consistent reflectance mosaics and reflectance spectra shape between different areas and dates.

  19. RADIOMETRIC CORRECTION OF MULTITEMPORAL HYPERSPECTRAL UAS IMAGE MOSAICS OF SEEDLING STANDS

    Directory of Open Access Journals (Sweden)

    L. Markelin

    2017-10-01

    Full Text Available Novel miniaturized multi- and hyperspectral imaging sensors on board of unmanned aerial vehicles have recently shown great potential in various environmental monitoring and measuring tasks such as precision agriculture and forest management. These systems can be used to collect dense 3D point clouds and spectral information over small areas such as single forest stands or sample plots. Accurate radiometric processing and atmospheric correction is required when data sets from different dates and sensors, collected in varying illumination conditions, are combined. Performance of novel radiometric block adjustment method, developed at Finnish Geospatial Research Institute, is evaluated with multitemporal hyperspectral data set of seedling stands collected during spring and summer 2016. Illumination conditions during campaigns varied from bright to overcast. We use two different methods to produce homogenous image mosaics and hyperspectral point clouds: image-wise relative correction and image-wise relative correction with BRDF. Radiometric datasets are converted to reflectance using reference panels and changes in reflectance spectra is analysed. Tested methods improved image mosaic homogeneity by 5 % to 25 %. Results show that the evaluated method can produce consistent reflectance mosaics and reflectance spectra shape between different areas and dates.

  20. Data acquisition and processing - helicopter radiometric survey, Krageroe, 1998

    CERN Document Server

    Beard, L P

    2000-01-01

    On 07 October 1998 a helicopter radiometric survey was flown in the vicinity of Krageroe municipality. The purpose of the survey was to provide radiometric information to help assess radon hazard from radioactive rocks in the area. A total of 60 line-kilometres of radiometric data were acquired in a single flight, covering an area of approximately 3 square km with a 50-m line spacing. The data were collected by Geological Survey of Norway (NGU) personnel and processed at NGU. Radiometric data were reduced using the three-channel procedure recommended by the International Atomic Energy Association. All data were gridded using square cells with 30-m sides and geophysical maps were produced at a scale of 1:5000. This report covers aspects of data acquisition and processing (Author)

  1. Radiometric dating by alpha spectrometry on uranium series nuclides

    NARCIS (Netherlands)

    Wijk, Albert van der

    1987-01-01

    De Engelse titel van dit proegschrift \\"Radiometric Dating by Alpha Spectometry on Uranium Series Nuclides\\" kan in het Nederlands wellicht het best worden weergegeven door \\"ouderdomsdbepalingen door stralingsmeting aan kernen uit de uraniumreeks met behulp van alfaspectometrie\\". In dit laatste

  2. Radiometric flow injection analysis with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    Radiometric Flow Injection Analysis of a radioactive ([sup 131]I) sample is described. For analysis an ASIA (Ismatec) analyzer with a NaI(Tl) scintillation detector was used. (author) 5 refs.; 3 figs.

  3. Data acquisition and processing - helicopter radiometric survey, Krageroe, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Beard, Les P.; Mogaard, John Olav

    2000-07-01

    On 07 October 1998 a helicopter radiometric survey was flown in the vicinity of Krageroe municipality. The purpose of the survey was to provide radiometric information to help assess radon hazard from radioactive rocks in the area. A total of 60 line-kilometres of radiometric data were acquired in a single flight, covering an area of approximately 3 square km with a 50-m line spacing. The data were collected by Geological Survey of Norway (NGU) personnel and processed at NGU. Radiometric data were reduced using the three-channel procedure recommended by the International Atomic Energy Association. All data were gridded using square cells with 30-m sides and geophysical maps were produced at a scale of 1:5000. This report covers aspects of data acquisition and processing (Author)

  4. Diagnostic Performance of a Rapid Magnetic Resonance Imaging Method of Measuring Hepatic Steatosis

    Science.gov (United States)

    House, Michael J.; Gan, Eng K.; Adams, Leon A.; Ayonrinde, Oyekoya T.; Bangma, Sander J.; Bhathal, Prithi S.; Olynyk, John K.; St. Pierre, Tim G.

    2013-01-01

    Objectives Hepatic steatosis is associated with an increased risk of developing serious liver disease and other clinical sequelae of the metabolic syndrome. However, visual estimates of steatosis from histological sections of biopsy samples are subjective and reliant on an invasive procedure with associated risks. The aim of this study was to test the ability of a rapid, routinely available, magnetic resonance imaging (MRI) method to diagnose clinically relevant grades of hepatic steatosis in a cohort of patients with diverse liver diseases. Materials and Methods Fifty-nine patients with a range of liver diseases underwent liver biopsy and MRI. Hepatic steatosis was quantified firstly using an opposed-phase, in-phase gradient echo, single breath-hold MRI methodology and secondly, using liver biopsy with visual estimation by a histopathologist and by computer-assisted morphometric image analysis. The area under the receiver operating characteristic (ROC) curve was used to assess the diagnostic performance of the MRI method against the biopsy observations. Results The MRI approach had high sensitivity and specificity at all hepatic steatosis thresholds. Areas under ROC curves were 0.962, 0.993, and 0.972 at thresholds of 5%, 33%, and 66% liver fat, respectively. MRI measurements were strongly associated with visual (r2 = 0.83) and computer-assisted morphometric (r2 = 0.84) estimates of hepatic steatosis from histological specimens. Conclusions This MRI approach, using a conventional, rapid, gradient echo method, has high sensitivity and specificity for diagnosing liver fat at all grades of steatosis in a cohort with a range of liver diseases. PMID:23555650

  5. A rapid and highly selective method for the estimation of pyro-, tri- and orthophosphates.

    Science.gov (United States)

    Kamat, D R; Savant, V V; Sathyanarayana, D N

    1995-03-01

    A rapid, highly selective and simple method has been developed for the quantitative determination of pyro-, tri- and orthophosphates. The method is based on the formation of a solid complex of bis(ethylenediamine)cobalt(III) species with pyrophosphate at pH 4.2-4.3, with triphosphate at pH 2.0-2.1 and with orthophosphate at pH 8.2-8.6. The proposed method for pyro- and triphosphates differs from the available method, which is based on the formation of an adduct with tris(ethylenediamine)cobalt(III) species. The complexes have the composition [Co(en)(2)HP(2)O(7)]4H(2)O and [Co(en)(2)H(2)P(3)O(10)]2H(2)O, respectively. The precipitation is instantaneous and quantitative under the recommended optimum conditions giving 99.5% gravimetric yield in both cases. There is no interferences from orthophosphate, trimetaphosphate and pyrophosphate species in the triphosphate estimation up to 5% of each component. The efficacy of the method has been established by determining pyrophosphate and triphosphate contents in various matrices. In the case of orthophosphate, the proposed method differs from the available methods such as ammonium phosphomolybdate, vanadophosphomolybdate and quinoline phosphomolybdate, which are based on the formation of a precipitate, followed by either titrimetry or gravimetry. The precipitation is instantaneous and the method is simple. Under the recommended pH and other reaction conditions, gravimetric yields of 99.6-100% are obtainable. The method is applicable to orthophosphoric acid and a variety of phosphate salts.

  6. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. II

    International Nuclear Information System (INIS)

    Harangozo, M.; Jombik, J.; Schiller, P.; Toelgyessy, J.

    1981-01-01

    A method for the determination of citric, tartaric and undecylenic acids based on radiometric titration with 0.1 or 0.05 mole.l -1 NaOH was developed. As an indicator of the end point, radioactive kryptonate of glass was used. Experimental technique, results of determinations as well as other possible applications of the radioactive kryptonate of glass for end point determination in alkalimetric analyses of officinal pharmaceuticals are discussed. (author)

  7. Impact of the cameras radiometric resolution on the accuracy of determining spectral reflectance coefficients

    Science.gov (United States)

    Orych, A.; Walczykowski, P.; Jenerowicz, A.; Zdunek, Z.

    2014-11-01

    Nowadays remote sensing plays a very important role in many different study fields, i.e. environmental studies, hydrology, mineralogy, ecosystem studies, etc. One of the key areas of remote sensing applications is water quality monitoring. Understanding and monitoring of the water quality parameters and detecting different water contaminants is an important issue in water management and protection of whole environment and especially the water ecosystem. There are many remote sensing methods to monitor water quality and detect water pollutants. One of the most widely used method for substance detection with remote sensing techniques is based on usage of spectral reflectance coefficients. They are usually acquired using discrete methods such as spectrometric measurements. These however can be very time consuming, therefore image-based methods are used more and more often. In order to work out the proper methodology of obtaining spectral reflectance coefficients from hyperspectral and multispectral images, it is necessary to verify the impact of cameras radiometric resolution on the accuracy of determination of them. This paper presents laboratory experiments that were conducted using two monochromatic XEVA video sensors (400-1700 nm spectral data registration) with two different radiometric resolutions (12 and 14 bits). In view of determining spectral characteristics from images, the research team used set of interferometric filters. All data collected with multispectral digital video cameras were compared with spectral reflectance coefficients obtained with spectroradiometer. The objective of this research is to find the impact of cameras radiometric resolution on reflectance values in chosen wavelength. The main topic of this study is the analysis of accuracy of spectral coefficients from sensors with different radiometric resolution. By comparing values collected from images acquired with XEVA sensors and with the curves obtained with spectroradiometer it

  8. Development of rapid methods for relaxation time mapping and motion estimation using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gilani, Syed Irtiza Ali

    2008-09-15

    Recent technological developments in the field of magnetic resonance imaging have resulted in advanced techniques that can reduce the total time to acquire images. For applications such as relaxation time mapping, which enables improved visualisation of in vivo structures, rapid imaging techniques are highly desirable. TAPIR is a Look- Locker-based sequence for high-resolution, multislice T{sub 1} relaxation time mapping. Despite the high accuracy and precision of TAPIR, an improvement in the k-space sampling trajectory is desired to acquire data in clinically acceptable times. In this thesis, a new trajectory, termed line-sharing, is introduced for TAPIR that can potentially reduce the acquisition time by 40 %. Additionally, the line-sharing method was compared with the GRAPPA parallel imaging method. These methods were employed to reconstruct time-point images from the data acquired on a 4T high-field MR research scanner. Multislice, multipoint in vivo results obtained using these methods are presented. Despite improvement in acquisition speed, through line-sharing, for example, motion remains a problem and artefact-free data cannot always be obtained. Therefore, in this thesis, a rapid technique is introduced to estimate in-plane motion. The presented technique is based on calculating the in-plane motion parameters, i.e., translation and rotation, by registering the low-resolution MR images. The rotation estimation method is based on the pseudo-polar FFT, where the Fourier domain is composed of frequencies that reside in an oversampled set of non-angularly, equispaced points. The essence of the method is that unlike other Fourier-based registration schemes, the employed approach does not require any interpolation to calculate the pseudo-polar FFT grid coordinates. Translation parameters are estimated by the phase correlation method. However, instead of two-dimensional analysis of the phase correlation matrix, a low complexity subspace identification of the phase

  9. Development of rapid methods for relaxation time mapping and motion estimation using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Gilani, Syed Irtiza Ali

    2008-09-01

    Recent technological developments in the field of magnetic resonance imaging have resulted in advanced techniques that can reduce the total time to acquire images. For applications such as relaxation time mapping, which enables improved visualisation of in vivo structures, rapid imaging techniques are highly desirable. TAPIR is a Look- Locker-based sequence for high-resolution, multislice T 1 relaxation time mapping. Despite the high accuracy and precision of TAPIR, an improvement in the k-space sampling trajectory is desired to acquire data in clinically acceptable times. In this thesis, a new trajectory, termed line-sharing, is introduced for TAPIR that can potentially reduce the acquisition time by 40 %. Additionally, the line-sharing method was compared with the GRAPPA parallel imaging method. These methods were employed to reconstruct time-point images from the data acquired on a 4T high-field MR research scanner. Multislice, multipoint in vivo results obtained using these methods are presented. Despite improvement in acquisition speed, through line-sharing, for example, motion remains a problem and artefact-free data cannot always be obtained. Therefore, in this thesis, a rapid technique is introduced to estimate in-plane motion. The presented technique is based on calculating the in-plane motion parameters, i.e., translation and rotation, by registering the low-resolution MR images. The rotation estimation method is based on the pseudo-polar FFT, where the Fourier domain is composed of frequencies that reside in an oversampled set of non-angularly, equispaced points. The essence of the method is that unlike other Fourier-based registration schemes, the employed approach does not require any interpolation to calculate the pseudo-polar FFT grid coordinates. Translation parameters are estimated by the phase correlation method. However, instead of two-dimensional analysis of the phase correlation matrix, a low complexity subspace identification of the phase

  10. Complex optimization of radiometric control and measurement systems

    International Nuclear Information System (INIS)

    Onishchenko, A.M.

    1995-01-01

    Fundamentals of a new approach to increase in the accuracy of radiometric systems of control and measurements are presented in succession. Block diagram of the new concept of radiometric system optimization is provided. The approach involving radical increase in accuracy and envisages ascertaining of controlled parameter by the totality of two intelligence signals closely correlated with each other. The new concept makes use of system analysis as a unified one-piece object, permitting euristic synthesis of the system. 4 refs., 3 figs

  11. [Research on rapid and quantitative detection method for organophosphorus pesticide residue].

    Science.gov (United States)

    Sun, Yuan-Xin; Chen, Bing-Tai; Yi, Sen; Sun, Ming

    2014-05-01

    The methods of physical-chemical inspection is adopted in the traditional pesticide residue detection, which require a lot of pretreatment processes, are time-consuming and complicated. In the present study, the authors take chlorpyrifos applied widely in the present agricultural field as the research object and propose a rapid and quantitative detection method for organophosphorus pesticide residues. At first, according to the chemical characteristics of chlorpyrifos and comprehensive chromogenic effect of several colorimetric reagents and secondary pollution, the pretreatment of the scheme of chromogenic reaction of chlorpyrifos with resorcin in a weak alkaline environment was determined. Secondly, by analyzing Uv-Vis spectrum data of chlorpyrifos samples whose content were between 0. 5 and 400 mg kg-1, it was confirmed that the characteristic information after the color reaction mainly was concentrated among 360 approximately 400 nm. Thirdly, the full spectrum forecasting model was established based on the partial least squares, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 995 6, standard deviation of calibration (RMSEC) was 2. 814 7 mg kg-1, and standard deviation of verification (RMSEP) was 8. 012 4 mg kg-1. Fourthly, the wavelengths whose center wavelength is 400 nm was extracted as characteristic region to build a forecasting model, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 999 3, standard deviation of calibration (RMSEC) was 2. 566 7 mg kg-1 , standard deviation of verification (RMSEP) was 4. 886 6 mg kg-1, respectively. At last, by analyzing the near infrared spectrum data of chlorpyrifos samples with contents between 0. 5 and 16 mg kg-1, the authors found that although the characteristics of the chromogenic functional group are not obvious, the change of absorption peaks of resorcin itself in the neighborhood of 5 200 cm

  12. Pyroprinting: a rapid and flexible genotypic fingerprinting method for typing bacterial strains.

    Science.gov (United States)

    Black, Michael W; VanderKelen, Jennifer; Montana, Aldrin; Dekhtyar, Alexander; Neal, Emily; Goodman, Anya; Kitts, Christopher L

    2014-10-01

    Bacterial strain typing is commonly employed in studies involving epidemiology, population ecology, and microbial source tracking to identify sources of fecal contamination. Methods for differentiating strains generally use either a collection of phenotypic traits or rely on some interrogation of the bacterial genotype. This report introduces pyroprinting, a novel genotypic strain typing method that is rapid, inexpensive, and discriminating compared to the most sensitive methods already in use. Pyroprinting relies on the simultaneous pyrosequencing of polymorphic multicopy loci, such as the intergenic transcribed spacer regions of rRNA operons in bacterial genomes. Data generated by sequencing combinations of variable templates are reproducible and intrinsically digitized. The theory and development of pyroprinting in Escherichia coli, including the selection of similarity thresholds to define matches between isolates, are presented. The pyroprint-based strain differentiation limits and phylogenetic relevance compared to other typing methods are also explored. Pyroprinting is unique in its simplicity and, paradoxically, in its intrinsic complexity. This new approach serves as an excellent alternative to more cumbersome or less phylogenetically relevant strain typing methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Development of a micropulverized extraction method for rapid toxicological analysis of methamphetamine in hair.

    Science.gov (United States)

    Miyaguchi, Hajime; Kakuta, Masaya; Iwata, Yuko T; Matsuda, Hideaki; Tazawa, Hidekatsu; Kimura, Hiroko; Inoue, Hiroyuki

    2007-09-07

    We developed a rapid sample preparation method for the toxicological analysis of methamphetamine and amphetamine (the major metabolite of methamphetamine) in human hair by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), to facilitate fast screening and quantitation. Two milligrams of hair were mechanically micropulverized for 5 min in a 2-ml plastic tube together with 100 microl of an aqueous solvent containing 10% acetonitrile, 100 mM trifluoroacetic acid and the corresponding deuterium analogues as internal standards. The pulverizing highly disintegrated the hair components, simultaneously allowing the extraction of any drugs present in the hair. After filtering the suspension with a membrane-filter unit, the clear filtrate was directly analyzed by HPLC-MS/MS. No evaporation processes were required for sample preparation. Method optimization and validation study were carried out using real-case specimens and fortified samples in which the drugs had been artificially absorbed, respectively. Concentration ranges for quantitation were 0.040-125 and 0.040-25 ng/mg for methamphetamine and amphetamine, respectively. Real-case specimens were analyzed by the method presented here and by conventional ones to verify the applicability of our method to real-world analysis. Our method took less than 30 min for a set of chromatograms to be obtained from a washed hair sample.

  14. A Rapid and Efficient Screening Method for Antibacterial Compound-Producing Bacteria.

    Science.gov (United States)

    Hettiarachchi, Sachithra; Lee, Su-Jin; Lee, Youngdeuk; Kwon, Young-Kyung; De Zoysa, Mahanama; Moon, Song; Jo, Eunyoung; Kim, Taeho; Kang, Do-Hyung; Heo, Soo-Jin; Oh, Chulhong

    2017-08-28

    Antibacterial compounds are widely used in the treatment of human and animal diseases. The overuse of antibiotics has led to a rapid rise in the prevalence of drug-resistant bacteria, making the development of new antibacterial compounds essential. This study focused on developing a fast and easy method for identifying marine bacteria that produce antibiotic compounds. Eight randomly selected marine target bacterial species ( Agrococcus terreus, Bacillus algicola, Mesoflavibacter zeaxanthinifaciens, Pseudoalteromonas flavipulchra, P. peptidolytica, P. piscicida, P. rubra , and Zunongwangia atlantica ) were tested for production of antibacterial compounds against four strains of test bacteria ( B. cereus, B. subtilis, Halomonas smyrnensis , and Vibrio alginolyticus ). Colony picking was used as the primary screening method. Clear zones were observed around colonies of P. flavipulchra, P. peptidolytica, P. piscicida , and P. rubra tested against B. cereus, B. subtilis , and H. smyrnensis . The efficiency of colony scraping and broth culture methods for antimicrobial compound extraction was also compared using a disk diffusion assay. P. peptidolytica, P. piscicida , and P. rubra showed antagonistic activity against H. smyrnensis, B. cereus , and B. subtilis , respectively, only in the colony scraping method. Our results show that colony picking and colony scraping are effective, quick, and easy methods of screening for antibacterial compound-producing bacteria.

  15. A rapid method for myoglobin radioimmunoanalysis as a diagnostic tool in myocardial infarction

    International Nuclear Information System (INIS)

    Grachev, M.A.; Matveev, L.E.; Pressman, E.K.; Roschke, V.V.

    1982-01-01

    Stone et al. have elaborated a RIA-method for the determination of myoglobin, and found that increase of its concentration in serum is a reliable criterion for the diagnosis of myocardial infarction. However, the test took 24-28 h. Subsequently, the time of the analysis has been reduced to 5-6 h. Recently, a rapid method for the determination of myoglobin has been proposed based upon the use of antiserum immobilized on a powdered carrier. This method takes a little more than 1 h. The procedure according to Roxin et al. is fast due to its non-equilibrium character; after the incubation (30 min) the reaction of the antigen with the immobilized antibody still remains far from equilibrium. It is generally believed that non-equilibrium RIA procedures are less convenient than equilibrium ones for practical clinical applications. According to the RIA procedure proposed here, the time saving compared with the established methods is achieved by using relatively-high concentrations of radioactive myoglobin of moderate specific radioactivity. Under these conditions, the kinetic plateau is reached in 15-20 min. Hence, the total time of the analysis to obtain a standard curve and results for five unknown sera is 55 min. Therefore, the method becomes more useful as a guide in the treatment of myocardial infarction. (Auth.)

  16. Calibrated infrared ground/air radiometric spectrometer

    Science.gov (United States)

    Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.

    1996-06-01

    The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).

  17. Inverting radiometric measurements with a neural network

    Science.gov (United States)

    Measure, Edward M.; Yee, Young P.; Balding, Jeff M.; Watkins, Wendell R.

    1992-02-01

    A neural network scheme for retrieving remotely sensed vertical temperature profiles was applied to observed ground based radiometer measurements. The neural network used microwave radiance measurements and surface measurements of temperature and pressure as inputs. Because the microwave radiometer is capable of measuring 4 oxygen channels at 5 different elevation angles (9, 15, 25, 40, and 90 degs), 20 microwave measurements are potentially available. Because these measurements have considerable redundancy, a neural network was experimented with, accepting as inputs microwave measurements taken at 53.88 GHz, 40 deg; 57.45 GHz, 40 deg; and 57.45, 90 deg. The primary test site was located at White Sands Missile Range (WSMR), NM. Results are compared with measurements made simultaneously with balloon borne radiosonde instruments and with radiometric temperature retrievals made using more conventional retrieval algorithms. The neural network was trained using a Widrow-Hoff delta rule procedure. Functions of date to include season dependence in the retrieval process and functions of time to include diurnal effects were used as inputs to the neural network.

  18. A Method to Represent Heterogeneous Materials for Rapid Prototyping: The Matryoshka Approach

    Science.gov (United States)

    Lei, Shuangyan; Frank, Matthew C.; Anderson, Donald D.; Brown, Thomas D.

    2015-01-01

    Purpose The purpose of this paper is to present a new method for representing heterogeneous materials using nested STL shells, based, in particular, on the density distributions of human bones. Design/methodology/approach Nested STL shells, called Matryoshka models, are described, based on their namesake Russian nesting dolls. In this approach, polygonal models, such as STL shells, are “stacked” inside one another to represent different material regions. The Matryoshka model addresses the challenge of representing different densities and different types of bone when reverse engineering from medical images. The Matryoshka model is generated via an iterative process of thresholding the Hounsfield Unit (HU) data using computed tomography (CT), thereby delineating regions of progressively increasing bone density. These nested shells can represent regions starting with the medullary (bone marrow) canal, up through and including the outer surface of the bone. Findings The Matryoshka approach introduced can be used to generate accurate models of heterogeneous materials in an automated fashion, avoiding the challenge of hand-creating an assembly model for input to multi-material additive or subtractive manufacturing. Originality/Value This paper presents a new method for describing heterogeneous materials: in this case, the density distribution in a human bone. The authors show how the Matryoshka model can be used to plan harvesting locations for creating custom rapid allograft bone implants from donor bone. An implementation of a proposed harvesting method is demonstrated, followed by a case study using subtractive rapid prototyping to harvest a bone implant from a human tibia surrogate. PMID:26120277

  19. A Rapid and Improved Method to Generate Recombinant Dengue Virus Vaccine Candidates.

    Science.gov (United States)

    Govindarajan, Dhanasekaran; Guan, Liming; Meschino, Steven; Fridman, Arthur; Bagchi, Ansu; Pak, Irene; ter Meulen, Jan; Casimiro, Danilo R; Bett, Andrew J

    2016-01-01

    Dengue is one of the most important mosquito-borne infections accounting for severe morbidity and mortality worldwide. Recently, the tetravalent chimeric live attenuated Dengue vaccine Dengvaxia® was approved for use in several dengue endemic countries. In general, live attenuated vaccines (LAV) are very efficacious and offer long-lasting immunity against virus-induced disease. Rationally designed LAVs can be generated through reverse genetics technology, a method of generating infectious recombinant viruses from full length cDNA contained in bacterial plasmids. In vitro transcribed (IVT) viral RNA from these infectious clones is transfected into susceptible cells to generate recombinant virus. However, the generation of full-length dengue virus cDNA clones can be difficult due to the genetic instability of viral sequences in bacterial plasmids. To circumvent the need for a single plasmid containing a full length cDNA, in vitro ligation of two or three cDNA fragments contained in separate plasmids can be used to generate a full-length dengue viral cDNA template. However, in vitro ligation of multiple fragments often yields low quality template for IVT reactions, resulting in inconsistent low yield RNA. These technical difficulties make recombinant virus recovery less efficient. In this study, we describe a simple, rapid and efficient method of using LONG-PCR to recover recombinant chimeric Yellow fever dengue (CYD) viruses as potential dengue vaccine candidates. Using this method, we were able to efficiently generate several viable recombinant viruses without introducing any artificial mutations into the viral genomes. We believe that the techniques reported here will enable rapid and efficient recovery of recombinant flaviviruses for evaluation as vaccine candidates and, be applicable to the recovery of other RNA viruses.

  20. A Rapid and Improved Method to Generate Recombinant Dengue Virus Vaccine Candidates.

    Directory of Open Access Journals (Sweden)

    Dhanasekaran Govindarajan

    Full Text Available Dengue is one of the most important mosquito-borne infections accounting for severe morbidity and mortality worldwide. Recently, the tetravalent chimeric live attenuated Dengue vaccine Dengvaxia® was approved for use in several dengue endemic countries. In general, live attenuated vaccines (LAV are very efficacious and offer long-lasting immunity against virus-induced disease. Rationally designed LAVs can be generated through reverse genetics technology, a method of generating infectious recombinant viruses from full length cDNA contained in bacterial plasmids. In vitro transcribed (IVT viral RNA from these infectious clones is transfected into susceptible cells to generate recombinant virus. However, the generation of full-length dengue virus cDNA clones can be difficult due to the genetic instability of viral sequences in bacterial plasmids. To circumvent the need for a single plasmid containing a full length cDNA, in vitro ligation of two or three cDNA fragments contained in separate plasmids can be used to generate a full-length dengue viral cDNA template. However, in vitro ligation of multiple fragments often yields low quality template for IVT reactions, resulting in inconsistent low yield RNA. These technical difficulties make recombinant virus recovery less efficient. In this study, we describe a simple, rapid and efficient method of using LONG-PCR to recover recombinant chimeric Yellow fever dengue (CYD viruses as potential dengue vaccine candidates. Using this method, we were able to efficiently generate several viable recombinant viruses without introducing any artificial mutations into the viral genomes. We believe that the techniques reported here will enable rapid and efficient recovery of recombinant flaviviruses for evaluation as vaccine candidates and, be applicable to the recovery of other RNA viruses.

  1. Rapid Hydrothermal Synthesis of Zinc Oxide Nanowires by Annealing Methods on Seed Layers

    Directory of Open Access Journals (Sweden)

    Jang Bo Shim

    2011-01-01

    Full Text Available Well-aligned zinc oxide (ZnO nanowire arrays were successfully synthesized on a glass substrate using the rapid microwave heating process. The ZnO seed layers were produced by spinning the precursor solutions onto the substrate. Among coatings, the ZnO seed layers were annealed at 100°C for 5 minutes to ensure particle adhesion to the glass surface in air, nitrogen, and vacuum atmospheres. The annealing treatment of the ZnO seed layer was most important for achieving the high quality of ZnO nanowire arrays as ZnO seed nanoparticles of larger than 30 nm in diameter evolve into ZnO nanowire arrays. Transmission electron microscopy analysis revealed a single-crystalline lattice of the ZnO nanowires. Because of their low power (140 W, low operating temperatures (90°C, easy fabrication (variable microwave sintering system, and low cost (90% cost reduction compared with gas condensation methods, high quality ZnO nanowires created with the rapid microwave heating process show great promise for use in flexible solar cells and flexible display devices.

  2. Comprehensive and Methodical: Diagnostic and Management Approaches to Rapidly Progressive Dementia.

    Science.gov (United States)

    Mahajan, Supriya; Appleby, Brian S

    2017-09-30

    Purpose of review The sudden emergence of a change in cognitive abilities or behavior is an important symptom that warrants medical evaluation and may represent the early stages of a rapidly progressive dementia (RPD). To correctly ascertain the cause of RPD in a given patient, the clinician must be methodical and knowledgeable about the range of potential causes and must move forward with supportive treatment, and in some cases empiric treatment, based on clinical features alone. Recent findings Significant advances in prion disease biomarkers, the molecular features of rapidly progressive Alzheimer's disease, and new detection of autoimmune limbic encephalitis disease entities have caused a shift in the diagnostic and treatment framework of RPD. Additionally, in the past decade, emerging retrospective data have led to suggested treatments in autoimmune encephalitis that, if instituted early, can protect patients against residual deficits and disease relapse. Summary Here, we provide an integrative clinical and diagnostic treatment approach that is applicable to the various forms of RPD. We have highlighted the clinical features of selected types of RPD that have experienced advances in the last 10-15 years.

  3. OSO paradigm--A rapid behavioral screening method for acute psychosocial stress reactivity in mice.

    Science.gov (United States)

    Brzózka, M M; Unterbarnscheidt, T; Schwab, M H; Rossner, M J

    2016-02-09

    Chronic psychosocial stress is an important environmental risk factor for the development of psychiatric diseases. However, studying the impact of chronic psychosocial stress in mice is time consuming and thus not optimally suited to 'screen' increasing numbers of genetically manipulated mouse models for psychiatric endophenotypes. Moreover, many studies focus on restraint stress, a strong physical stressor with limited relevance for psychiatric disorders. Here, we describe a simple and a rapid method based on the resident-intruder paradigm to examine acute effects of mild psychosocial stress in mice. The OSO paradigm (open field--social defeat--open field) compares behavioral consequences on locomotor activity, anxiety and curiosity before and after exposure to acute social defeat stress. We first evaluated OSO in male C57Bl/6 wildtype mice where a single episode of social defeat reduced locomotor activity, increased anxiety and diminished exploratory behavior. Subsequently, we applied the OSO paradigm to mouse models of two schizophrenia (SZ) risk genes. Transgenic mice with neuronal overexpression of Neuregulin-1 (Nrg1) type III showed increased risk-taking behavior after acute stress exposure suggesting that NRG1 dysfunction is associated with altered affective behavior. In contrast, Tcf4 transgenic mice displayed a normal stress response which is in line with the postulated predominant contribution of TCF4 to cognitive deficits of SZ. In conclusion, the OSO paradigm allows for rapid screening of selected psychosocial stress-induced behavioral endophenotypes in mouse models of psychiatric diseases. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  4. Performance of a Micro-UAV lifting system built with the usage of rapid prototyping methods

    International Nuclear Information System (INIS)

    Dalewski, R T; Gumowski, K; Barczak, T; Godek, J

    2014-01-01

    This article presents results of the aerodynamic testing of a micro unmanned aerial vehicle rotor efficiency. The rotors were prepared as a set of two rotors in a counter-rotating ducted drive. Prototypes of the drives were made using two rapid prototyping techniques – FDM – fused deposition modelling method and SLS – selective laser sintering. Rotors were made then treated by introducing additional finishing cyanoacrylate coating and abrasive processing. Main differences between those models were observed in fan shape, porosity, surface roughness and mechanical properties – stiffness. An influence of these factors was observed on an aerodynamic efficiency. For the obtained prototypes both simulations and experimental testing were conducted with thrust, power, torque measurements, as well as the measurement of velocity and pressure distribution at the outlet of the duct. The results show the possibility of using rapid prototyping techniques to produce prototypes of drives operating in the low and medium Reynolds numbers (6000-60000), and the aerodynamic shape relevant factors affecting the preparation and performance of such drives. In addition, simulation studies were performed using the Fluent environment where experimental results were confronted with the results of simulation studies.

  5. A rapid method for infectivity titration of Andes hantavirus using flow cytometry.

    Science.gov (United States)

    Barriga, Gonzalo P; Martínez-Valdebenito, Constanza; Galeno, Héctor; Ferrés, Marcela; Lozach, Pierre-Yves; Tischler, Nicole D

    2013-11-01

    The focus assay is currently the most commonly used technique for hantavirus titer determination. This method requires an incubation time of between 5 and 11 days to allow the appearance of foci after several rounds of viral infection. The following work presents a rapid Andes virus (ANDV) titration assay, based on viral nucleocapsid protein (N) detection in infected cells by flow cytometry. To this end, an anti-N monoclonal antibody was used that was developed and characterized previously. ANDV N could be detected as early as 6 h post-infection, while viral release was not observed until 24-48 h post-infection. Given that ANDV detection was performed during its first round of infection, a time reduction for titer determination was possible and provided results in only two days. The viral titer was calculated from the percentage of N positive cells and agreed with focus assay titers. Furthermore, the assay was applied to quantify the inhibition of ANDV cell entry by patient sera and by preventing endosome acidification. This novel hantavirus titration assay is a highly quantitative and sensitive tool that facilitates infectivity titration of virus stocks, rapid screening for antiviral drugs, and may be further used to detect and quantify infectious virus in human samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT Based on Time-Resolved Immunochromatography

    Directory of Open Access Journals (Sweden)

    Xiang-Yang Shao

    2017-02-01

    Full Text Available Procalcitonin (PCT is a current, frequently-used marker for severe bacterial infection. The aim of this study was to develop a cost-effective detection kit for rapid quantitative and on-site detection of PCT. To develop the new PCT quantitative detecting kit, a double-antibody sandwich immunofluorescent assay was employed based on time-resolved immunofluorescent assay (TRFIA combined with lateral flow immunoassay (LFIA. The performance of the new developed kit was evaluated in the aspects of linearity, precision, accuracy, and specificity. Two-hundred thirty-four serum samples were enrolled to carry out the comparison test. The new PCT quantitative detecting kit exhibited a higher sensitivity (0.08 ng/mL. The inter-assay coefficient of variation (CV and the intra-assay CV were 5.4%–7.7% and 5.7%–13.4%, respectively. The recovery rates ranged from 93% to 105%. Furthermore, a high correlation (n = 234, r = 0.977, p < 0.0001 and consistency (Kappa = 0.875 were obtained when compared with the PCT kit from Roche Elecsys BRAHMS. Thus, the new quantitative method for detecting PCT has been successfully established. The results indicated that the newly-developed system based on TRFIA combined with LFIA was suitable for rapid and on-site detection for PCT, which might be a useful platform for other biomarkers in point-of-care tests.

  7. Rapid and simple colorimetric method for the quantification of AI-2 produced from Salmonella Typhimurium.

    Science.gov (United States)

    Wattanavanitchakorn, Siriluck; Prakitchaiwattana, Cheunjit; Thamyongkit, Patchanita

    2014-04-01

    The aim of this study was to evaluate the feasibility of Fe(III) ion reduction for the simple and rapid quantification of autoinducer-2 (AI-2) produced from bacteria using Salmonella Typhimurium as a model. Since the molecular structure of AI-2 is somewhat similar to ascorbic acid it was expected that AI-2 would also act as a reducing agent and reduce Fe(III) ions in the presence of 1,10-phenanthroline to form the colored [(o-phen)3 Fe(II)]SO4 ferroin complex that could be quantified colorimetrically. In support of this, colony rinses and cell free supernatants from cultures of all tested AI-2 producing strains, but not the AI-2 negative Sinorhizobium meliloti, formed a colored complex with a λmax of 510nm. The OD510 values of these culture supernatants or colony rinses were in broad agreement with the % activity observed in the same samples using the standard Vibrio harveyi bioluminescence assay for AI-2 detection, and with previously reported results. This methodology could potentially be developed as an alternative method for the simple and rapid quantification of AI-2 levels produced in bacterial cultures. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Bacterial Cytological Profiling (BCP as a Rapid and Accurate Antimicrobial Susceptibility Testing Method for Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    D.T. Quach

    2016-02-01

    Full Text Available Successful treatment of bacterial infections requires the timely administration of appropriate antimicrobial therapy. The failure to initiate the correct therapy in a timely fashion results in poor clinical outcomes, longer hospital stays, and higher medical costs. Current approaches to antibiotic susceptibility testing of cultured pathogens have key limitations ranging from long run times to dependence on prior knowledge of genetic mechanisms of resistance. We have developed a rapid antimicrobial susceptibility assay for Staphylococcus aureus based on bacterial cytological profiling (BCP, which uses quantitative fluorescence microscopy to measure antibiotic induced changes in cellular architecture. BCP discriminated between methicillin-susceptible (MSSA and -resistant (MRSA clinical isolates of S. aureus (n = 71 within 1–2 h with 100% accuracy. Similarly, BCP correctly distinguished daptomycin susceptible (DS from daptomycin non-susceptible (DNS S. aureus strains (n = 20 within 30 min. Among MRSA isolates, BCP further identified two classes of strains that differ in their susceptibility to specific combinations of beta-lactam antibiotics. BCP provides a rapid and flexible alternative to gene-based susceptibility testing methods for S. aureus, and should be readily adaptable to different antibiotics and bacterial species as new mechanisms of resistance or multidrug-resistant pathogens evolve and appear in mainstream clinical practice.

  9. Rapid and efficient method to extract metagenomic DNA from estuarine sediments.

    Science.gov (United States)

    Shamim, Kashif; Sharma, Jaya; Dubey, Santosh Kumar

    2017-07-01

    Metagenomic DNA from sediments of selective estuaries of Goa, India was extracted using a simple, fast, efficient and environment friendly method. The recovery of pure metagenomic DNA from our method was significantly high as compared to other well-known methods since the concentration of recovered metagenomic DNA ranged from 1185.1 to 4579.7 µg/g of sediment. The purity of metagenomic DNA was also considerably high as the ratio of absorbance at 260 and 280 nm ranged from 1.88 to 1.94. Therefore, the recovered metagenomic DNA was directly used to perform various molecular biology experiments viz. restriction digestion, PCR amplification, cloning and metagenomic library construction. This clearly proved that our protocol for metagenomic DNA extraction using silica gel efficiently removed the contaminants and prevented shearing of the metagenomic DNA. Thus, this modified method can be used to recover pure metagenomic DNA from various estuarine sediments in a rapid, efficient and eco-friendly manner.

  10. Gas evolution as a rapid screening method for detection of irradiated foods

    International Nuclear Information System (INIS)

    Roberts, P.B.; Chambers, D.M.; Brailsford, G.W.

    1996-01-01

    A number of detection methods for irradiated foods are in advanced state of development. No single method is likely to be universally applicable but a battery of tests such as thermoluminescence, electron spin resonance and analysis of lipid radiolytic products may soon be available for most foods and technical uses of irradiation. Most of these proposed tests require relatively sophisticated equipment or technical skills and are often time consuming and costly. There would be value in relatively simple tests which could be used as a rapid screening system or confirmatory method. The literature on the use of radiolytic gases as a detection method is limited and this paper extends the above studies. In particular, it extends the work to frozen shellfish, for which irradiation has been used as a commercial decontaminant technique for many years, and considers the effect of storage temperature. Work on poultry is also reported as a cross-reference to earlier work and because irradiated poultry has recently been released into the US retail trade. (author)

  11. A rapid method combining Golgi and Nissl staining to study neuronal morphology and cytoarchitecture.

    Science.gov (United States)

    Pilati, Nadia; Barker, Matthew; Panteleimonitis, Sofoklis; Donga, Revers; Hamann, Martine

    2008-06-01

    The Golgi silver impregnation technique gives detailed information on neuronal morphology of the few neurons it labels, whereas the majority remain unstained. In contrast, the Nissl staining technique allows for consistent labeling of the whole neuronal population but gives very limited information on neuronal morphology. Most studies characterizing neuronal cell types in the context of their distribution within the tissue slice tend to use the Golgi silver impregnation technique for neuronal morphology followed by deimpregnation as a prerequisite for showing that neuron's histological location by subsequent Nissl staining. Here, we describe a rapid method combining Golgi silver impregnation with cresyl violet staining that provides a useful and simple approach to combining cellular morphology with cytoarchitecture without the need for deimpregnating the tissue. Our method allowed us to identify neurons of the facial nucleus and the supratrigeminal nucleus, as well as assessing cellular distribution within layers of the dorsal cochlear nucleus. With this method, we also have been able to directly compare morphological characteristics of neuronal somata at the dorsal cochlear nucleus when labeled with cresyl violet with those obtained with the Golgi method, and we found that cresyl violet-labeled cell bodies appear smaller at high cellular densities. Our observation suggests that cresyl violet staining is inadequate to quantify differences in soma sizes.

  12. Utilization of radiometric method in evaluation of wear on human dental enamel in vitro by dental porcelain glazed and polished; Utilizacao do metodo radiometrico na avaliacao in vitro do desgaste provocado ao esmalte dental humano por porcelanas dentais glazeadas e polidas

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Lena Katekawa; Campos, Tomie Nakakuki de; Adachi, Eduardo Makoto [Sao Paulo Univ., SP (Brazil). Faculdade de Odontologia. Dept. de Protese]. E-mail: katekawa@usp.br; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: mitiko@curiango.ipen.br

    2005-07-01

    The dental porcelain is a material commonly used in prosthesis. Disadvantages of dental porcelain use include possibility to cause tooth or dental materials wear. Before its use in the mouth, surfaces are treated with polishing and/or glazing. This research used the radiometric method to verify the influence of these surface treatments on the porcelains of commercial brands: Ceramco II, Noritake and Finesse. This method was originally developed for dentifrice abrasiveness evaluation. Five specimens of dental enamel and 10 specimens of each porcelain (5 glazed, 5 polished) were used. The dental enamel was flattened and irradiated with neutrons from the IEA-R1 (IPEN/CNEN) nuclear reactor. Then it was weared by each porcelain in sliding motion, with water. After 2,500 cycles for each porcelain specimen, the released enamel residue was measured. The enamel wear was evaluated by measuring beta activity of {sup 32}P transferred to water from the irradiated tooth. Results varied from 2.57 to 5.81 {mu}g of enamel /mm{sup 2} weared surface. There was no statistical difference ({alpha}=0.05) between dental enamel wear caused by the same porcelains glazed or polished. The results suggest that adequate surface finishing depend on the type of dental porcelain. (author)

  13. Radiometric Performance of the TerraSAR-X Mission over More Than Ten Years of Operation

    Directory of Open Access Journals (Sweden)

    Marco Schwerdt

    2018-05-01

    Full Text Available The TerraSAR-X mission, based on two satellites, has produced SAR data products of high quality for a number of scientific and commercial applications for more than ten years. To guarantee the stability and the reliability of these highly accurate SAR data products, both systems were first accurately calibrated during their respective commissioning phases and have been permanently monitored since then. Based on a short description of the methods applied, this paper focuses on the radiometric performance including the gain and phase properties of the transmit/receiver modules, the antenna pattern checked by evaluating scenes acquired over uniformly distributed targets and the radiometric stability derived from permanently deployed point targets. The outcome demonstrates the remarkable performance of both systems since their respective launch.

  14. A PCR detection method for rapid identification of Melissococcus pluton in honeybee larvae.

    Science.gov (United States)

    Govan, V A; Brözel, V; Allsopp, M H; Davison, S

    1998-05-01

    Melissococcus pluton is the causative agent of European foulbrood, a disease of honeybee larvae. This bacterium is particularly difficult to isolate because of its stringent growth requirements and competition from other bacteria. PCR was used selectively to amplify specific rRNA gene sequences of M. pluton from pure culture, from crude cell lysates, and directly from infected bee larvae. The PCR primers were designed from M. pluton 16S rRNA sequence data. The PCR products were visualized by agarose gel electrophoresis and confirmed as originating from M. pluton by sequencing in both directions. Detection was highly specific, and the probes did not hybridize with DNA from other bacterial species tested. This method enabled the rapid and specific detection and identification of M. pluton from pure cultures and infected bee larvae.

  15. A rapid method to estimate uranium using ionic liquid as extracting agent from basic aqueous media

    International Nuclear Information System (INIS)

    Prabhath Ravi, K.; Sathyapriya, R.S.; Rao, D.D.; Ghosh, S.K.

    2016-01-01

    Room temperature ionic liquids, as their name suggests are salts with a low melting point typically less than 100 °C and exist as liquid at room temperature. The common cationic parts of ionic liquids are imidazolium, pyridinium, pyrrolidinium, quaternary ammonium, or phosphonium ions, and common anionic parts are chloride, bromide, boron tetrafluorate, phosphorous hexafluorate, triflimide etc. The physical properties of ionic liquids can be tuned by choosing appropriate cations with differing alkyl chain lengths and anions. Application of ionic liquids in organic synthesis, liquid-liquid extractions, electrochemistry, catalysis, speciation studies, nuclear reprocessing is being studied extensively in recent times. In this paper a rapid method to estimate the uranium content in aqueous media by extraction with room temperature ionic liquid tricaprylammoniumthiosalicylate ((A- 336)(TS)) followed by liquid scintillation analysis is described. Re-extraction of uranium from ionic liquid phase to aqueous phase was also studied

  16. A rapid and economic in-house DNA purification method using glass syringe filters.

    Directory of Open Access Journals (Sweden)

    Yun-Cheol Kim

    Full Text Available BACKGROUND: Purity, yield, speed and cost are important considerations in plasmid purification, but it is difficult to achieve all of these at the same time. Currently, there are many protocols and kits for DNA purification, however none maximize all four considerations. METHODOLOGY/PRINCIPAL FINDINGS: We now describe a fast, efficient and economic in-house protocol for plasmid preparation using glass syringe filters. Plasmid yield and quality as determined by enzyme digestion and transfection efficiency were equivalent to the expensive commercial kits. Importantly, the time required for purification was much less than that required using a commercial kit. CONCLUSIONS/SIGNIFICANCE: This method provides DNA yield and quality similar to that obtained with commercial kits, but is more rapid and less costly.

  17. A rapid method for whole mount preparations of mammalian oocytes and early embryos.

    Science.gov (United States)

    Moses, R M; Masui, Y

    1994-05-01

    Whole mounts of mouse oocytes and embryos are useful for observing intracellular structures while preserving morphological integrity. This method is inconvenient for rapid processing of a large number of specimens because washing each specimen in a protein-free solution is required prior to transfer into the fixative. We have developed a new fixative which does not cause protein precipitation which can be added directly to the culture medium. Specimens can be preserved in culture dishes for at least one month, and processed for cytological observation at a convenient time. When stained with hematoxylin, details of cellular structures such as nuclei, nucleoli, chromosomes and spindle microtubules can be observed while maintaining the organization of the organelles.

  18. A robust and rapid method of producing soluble, stable, and functional G-protein coupled receptors.

    Directory of Open Access Journals (Sweden)

    Karolina Corin

    Full Text Available Membrane proteins, particularly G-protein coupled receptors (GPCRs, are notoriously difficult to express. Using commercial E. coli cell-free systems with the detergent Brij-35, we could rapidly produce milligram quantities of 13 unique GPCRs. Immunoaffinity purification yielded receptors at >90% purity. Secondary structure analysis using circular dichroism indicated that the purified receptors were properly folded. Microscale thermophoresis, a novel label-free and surface-free detection technique that uses thermal gradients, showed that these receptors bound their ligands. The secondary structure and ligand-binding results from cell-free produced proteins were comparable to those expressed and purified from HEK293 cells. Our study demonstrates that cell-free protein production using commercially available kits and optimal detergents is a robust technology that can be used to produce sufficient GPCRs for biochemical, structural, and functional analyses. This robust and simple method may further stimulate others to study the structure and function of membrane proteins.

  19. NATO Advanced Research Workshop, 19-22 May 1997: Rapid Method for Monitoring the Environment for Biological Hazards

    National Research Council Canada - National Science Library

    1997-01-01

    The NATO Advanced Research Workshop met for the purpose of bringing to light rapid methods for monitoring the environment for biological hazards such as biological warfare agents, naturally occurring...

  20. Use of predictive models and rapid methods to nowcast bacteria levels at coastal beaches

    Science.gov (United States)

    Francy, Donna S.

    2009-01-01

    The need for rapid assessments of recreational water quality to better protect public health is well accepted throughout the research and regulatory communities. Rapid analytical methods, such as quantitative polymerase chain reaction (qPCR) and immunomagnetic separation/adenosine triphosphate (ATP) analysis, are being tested but are not yet ready for widespread use.Another solution is the use of predictive models, wherein variable(s) that are easily and quickly measured are surrogates for concentrations of fecal-indicator bacteria. Rainfall-based alerts, the simplest type of model, have been used by several communities for a number of years. Deterministic models use mathematical representations of the processes that affect bacteria concentrations; this type of model is being used for beach-closure decisions at one location in the USA. Multivariable statistical models are being developed and tested in many areas of the USA; however, they are only used in three areas of the Great Lakes to aid in notifications of beach advisories or closings. These “operational” statistical models can result in more accurate assessments of recreational water quality than use of the previous day's Escherichia coli (E. coli)concentration as determined by traditional culture methods. The Ohio Nowcast, at Huntington Beach, Bay Village, Ohio, is described in this paper as an example of an operational statistical model. Because predictive modeling is a dynamic process, water-resource managers continue to collect additional data to improve the predictive ability of the nowcast and expand the nowcast to other Ohio beaches and a recreational river. Although predictive models have been shown to work well at some beaches and are becoming more widely accepted, implementation in many areas is limited by funding, lack of coordinated technical leadership, and lack of supporting epidemiological data.

  1. Rapid, convenient method for screening imidazole-containing compounds for heme oxygenase inhibition.

    Science.gov (United States)

    Vlahakis, Jason Z; Rahman, Mona N; Roman, Gheorghe; Jia, Zongchao; Nakatsu, Kanji; Szarek, Walter A

    2011-01-01

    Sensitive assays for measuring heme oxygenase activity have been based on the gas-chromatographic detection of carbon monoxide using elaborate, expensive equipment. The present study describes a rapid and convenient method for screening imidazole-containing candidates for inhibitory activity against heme oxygenase using a plate reader, based on the spectroscopic evaluation of heme degradation. A PowerWave XS plate reader was used to monitor the absorbance (as a function of time) of heme bound to purified truncated human heme oxygenase-1 (hHO-1) in the individual wells of a standard 96-well plate (with or without the addition of a test compound). The degradation of heme by heme oxygenase-1 was initiated using l-ascorbic acid, and the collected relevant absorbance data were analyzed by three different methods to calculate the percent control activity occurring in wells containing test compounds relative to that occurring in control wells with no test compound present. In the cases of wells containing inhibitory compounds, significant shifts in λ(max) from 404 to near 412 nm were observed as well as a decrease in the rate of heme degradation relative to that of the control. Each of the three methods of data processing (overall percent drop in absorbance over 1.5h, initial rate of reaction determined over the first 5 min, and estimated pseudo first-order reaction rate constant determined over 1.5h) gave similar and reproducible results for percent control activity. The fastest and easiest method of data analysis was determined to be that using initial rates, involving data acquisition for only 5 min once reactions have been initiated using l-ascorbic acid. The results of the study demonstrate that this simple assay based on the spectroscopic detection of heme represents a rapid, convenient method to determine the relative inhibitory activity of candidate compounds, and is useful in quickly screening a series or library of compounds for heme oxygenase inhibition

  2. A new rapid method for direct antimicrobial susceptibility testing of bacteria from positive blood cultures.

    Science.gov (United States)

    Barnini, Simona; Brucculeri, Veronica; Morici, Paola; Ghelardi, Emilia; Florio, Walter; Lupetti, Antonella

    2016-08-12

    Rapid identification and antimicrobial susceptibility testing (AST) of the causative agent(s) of bloodstream infections can lead to prompt appropriate antimicrobial therapy. To shorten species identification, in this study bacteria were recovered from monomicrobial blood cultures by serum separator tubes and spotted onto the target plate for direct MALDI-TOF MS identification. Proper antibiotics were selected for direct AST based on species identification. In order to obtain rapid AST results, bacteria were recovered from positive blood cultures by two different protocols: by serum separator tubes (further referred to as PR1), or after a short-term subculture in liquid medium (further referred to as PR2). The results were compared with those obtained by the method currently used in our laboratory consisting in identification by MALDI-TOF and AST by Vitek 2 or Sensititre on isolated colonies. The direct MALDI-TOF method concordantly identified with the current method 97.5 % of the Gram-negative bacteria and 96.1 % of the Gram-positive cocci contained in monomicrobial blood cultures. The direct AST by PR1 and PR2 for all isolate/antimicrobial agent combinations was concordant/correct with the current method for 87.8 and 90.5 % of Gram-negative bacteria and for 93.1 and 93.8 % of Gram-positive cocci, respectively. In particular, 100 % categorical agreement was found with levofloxacin for Enterobacteriaceae by both PR1 and PR2, and 99.0 and 100 % categorical agreement was observed with linezolid for Gram-positive cocci by PR1 and PR2, respectively. There was no significant difference in accuracy between PR1 and PR2 for Gram-negative bacteria and Gram-positive cocci. This newly described method seems promising for providing accurate AST results. Most importantly, these results would be available in a few hours from blood culture positivity, which would help clinicians to promptly confirm or streamline an effective antibiotic therapy in patients with bloodstream

  3. A rapid minor groove binder PCR method for distinguishing the vaccine strain Brucella abortus 104M.

    Science.gov (United States)

    Nan, Wenlong; Qin, Lide; Wang, Yong; Zhang, Yueyong; Tan, Pengfei; Chen, Yuqi; Mao, Kairong; Chen, Yiping

    2018-01-24

    Brucellosis is a widespread zoonotic disease caused by Gram-negative Brucella bacteria. Immunisation with attenuated vaccine is an effective method of prevention, but it can interfere with diagnosis. Live, attenuated Brucella abortus strain 104M has been used for the prevention of human brucellosis in China since 1965. However, at present, no fast and reliable method exists that can distinguish this strain from field strains. Single nucleotide polymorphism (SNP)-based assays offer a new approach for such discrimination. SNP-based minor groove binder (MGB) and Cycleave assays have been used for rapid identification of four Brucella vaccine strains (B. abortus strains S19, A19 and RB51, and B. melitensis Rev1). The main objective of this study was to develop a PCR assay for rapid and specific detection of strain 104M. We developed a SNP-based MGB PCR assay that could successfully distinguish strain 104M from 18 representative strains of Brucella (B. abortus biovars 1, 2, 3, 4, 5, 6, 7 and 9, B. melitensis biovars 1, 2 and 3, B. suis biovars 1, 2, 3 and 4, B. canis, B. neotomae, and B. ovis), four Brucella vaccine strains (A19, S19, S2, M5), and 55 Brucella clinical field strains. The assay gave a negative reaction with four non-Brucella species (Escherichia coli, Pasteurella multocida, Streptococcus suis and Pseudomonas aeruginosa). The minimum sensitivity of the assay, evaluated using 10-fold dilutions of chromosomal DNA, was 220 fg for the 104M strain and 76 fg for the single non-104M Brucella strain tested (B. abortus A19). The assay was also reproducible (intra- and inter-assay coefficients of variation = 0.006-0.022 and 0.012-0.044, respectively). A SNP-based MGB PCR assay was developed that could straightforwardly and unambiguously distinguish B. abortus vaccine strain 104M from non-104M Brucella strains. Compared to the classical isolation and identification approaches of bacteriology, this real-time PCR assay has substantial advantages in terms of

  4. A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

    Science.gov (United States)

    Mulligan, Jeffrey B.

    2016-01-01

    Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

  5. Aptamer-mediated colorimetric method for rapid and sensitive detection of chloramphenicol in food.

    Science.gov (United States)

    Yan, Chao; Zhang, Jing; Yao, Li; Xue, Feng; Lu, Jianfeng; Li, Baoguang; Chen, Wei

    2018-09-15

    We report an aptamer-mediated colorimetric method for sensitive detection of chloramphenicol (CAP). The aptamer of CAP is immobilized by the hybridization with pre-immobilized capture probe in the microtiter plate. The horseradish peroxidase (HRP) is covalently attached to the aptamer by the biotin-streptavidin system for signal production. CAP will preferably bind with aptamer due to the high binding affinity, which attributes to the release of aptamer and HRP and thus, affects the optical signal intensity. Quantitative determination of CAP is successfully achieved in the wide range from 0.001 to 1000 ng/mL with detection limit of 0.0031 ng/mL, which is more sensitive than traditional immunoassays. This method is further validated by measuring the recovery of CAP spiked in two different food matrices (honey and fish). The aptamer-mediated colorimetric method can be a useful protocol for rapid and sensitive screening of CAP, and may be used as an alternative means for traditional immunoassays. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Natural transformation of Vibrio parahaemolyticus: A rapid method to create genetic deletions.

    Science.gov (United States)

    Chimalapati, Suneeta; de Souza Santos, Marcela; Servage, Kelly; De Nisco, Nicole J; Dalia, Ankur B; Orth, Kim

    2018-03-19

    The Gram-negative bacterium Vibrio parahaemolyticus is an opportunistic human pathogen and the leading cause of seafood borne acute gastroenteritis worldwide. Recently, this bacterium was implicated as the etiologic agent of a severe shrimp disease with consequent devastating outcomes to shrimp farming. In both cases, acquisition of genetic material via horizontal transfer provided V. parahaemolyticus with new virulence tools to cause disease. Dissecting the molecular mechanisms of V. parahaemolyticus pathogenesis often requires manipulating its genome. Classically, genetic deletions in V. parahaemolyticus are performed using a laborious, lengthy, multi-step process. Herein, we describe a fast and efficient method to edit this bacterium's genome based on V. parahaemolyticus natural competence. Although this method is similar to one previously described, V. parahaemolyticus requires counter selection for curing of acquired plasmids due to its recalcitrant nature of retaining extrachromosomal DNA. We believe this approach will be of use to the Vibrio community. Importance Spreading of Vibrios throughout the world correlates with increased global temperatures. As they spread, they find new niches to survive, proliferate and invade. Therefore, genetic manipulation of Vibrios is of utmost importance for studying these species. Herein, we have delineated and validated a rapid method to create genetic deletions in Vibrio parahaemolyticus This study provides insightful methodology for studies with other Vibrio species. Copyright © 2018 American Society for Microbiology.

  7. Novel rapid method for the characterisation of polymeric sugars from macroalgae.

    Science.gov (United States)

    Spicer, S E; Adams, J M M; Thomas, D S; Gallagher, J A; Winters, Ana L

    2017-01-01

    Laminarins are storage polysaccharides found only in brown seaweeds, specifically Laminarialaes and Fucales. Laminarin has been shown to have anti-apoptotic and anti-tumoural activities and is considered as a nutraceutical component that can positively influence human health. The structure is species dependent, generally composed of linear ß(1-3) glucans with intrachain β(1-6) branching and varies according to harvest season and environmental factors. Current methods for analysis of molar mass and DP length are technically demanding and are not widely available. Here, we present a simple inexpensive method which enables rapid analysis of laminarins from macroalgal biomass using high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) without the need for hydrolysis or further processing. This is based on the linear relationship observed between log 10 DP and retention time following separation of laminarins on a CarboPac PA-100 column (Dionex) using standard 1,3-β-d-gluco-oligosaccharides ranging in DP from 2 to 8. This method was applied to analyse laminarin oligomers in extracts from different species harvested from within the intertidal zone on Welsh rocky shores containing laminarin polymers with different ranges of DP. The degree of polymerisation and extrapolated molar mass agreed well with values estimated by LC-ESI/MS n analysis and those reported in the literature.

  8. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured by the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.

  9. A Simple PCR Method for Rapid Genotype Analysis of Mycobacterium ulcerans

    Science.gov (United States)

    Stinear, Timothy; Davies, John K.; Jenkin, Grant A.; Portaels, Françoise; Ross, Bruce C.; OppEdIsano, Frances; Purcell, Maria; Hayman, John A.; Johnson, Paul D. R.

    2000-01-01

    Two high-copy-number insertion sequences, IS2404 and IS2606, were recently identified in Mycobacterium ulcerans and were shown by Southern hybridization to possess restriction fragment length polymorphism between strains from different geographic origins. We have designed a simple genotyping method that captures these differences by PCR amplification of the region between adjacent copies of IS2404 and IS2606. We have called this system 2426 PCR. The method is rapid, reproducible, sensitive, and specific for M. ulcerans, and it has confirmed previous studies suggesting a clonal population structure of M. ulcerans within a geographic region. M. ulcerans isolates from Australia, Papua New Guinea, Malaysia, Surinam, Mexico, Japan, China, and several countries in Africa were easily differentiated based on an array of 4 to 14 PCR products ranging in size from 200 to 900 bp. Numerical analysis of the banding patterns suggested a close evolutionary link between M. ulcerans isolates from Africa and southeast Asia. The application of 2426 PCR to total DNA, extracted directly from M. ulcerans-infected tissue specimens without culture, demonstrated the sensitivity and specificity of this method and confirmed for the first time that both animal and human isolates from areas of endemicity in southeast Australia have the same genotype. PMID:10747130

  10. Development of a rapid HRM genotyping method for detection of dog-derived Giardia lamblia.

    Science.gov (United States)

    Tan, Liping; Yu, Xingang; Abdullahi, Auwalu Yusuf; Wu, Sheng; Zheng, Guochao; Hu, Wei; Song, Meiran; Wang, Zhen; Jiang, Biao; Li, Guoqing

    2015-11-01

    Giardia lamblia is a zoonotic flagellate protozoan in the intestine of human and many mammals including dogs. To assess a threat of dog-derived G. lamblia to humans, the common dog-derived G. lamblia assemblages A, C, and D were genotyped by high-resolution melting (HRM) technology. According to β-giardin gene sequence, the qPCR-HRM primers BG5 and BG7 were designed. A series of experiments on the stability, sensitivity, and accuracy of the HRM method were also tested. Results showed that the primers BG5 and BG7 could distinguish among three assemblages A, C, and D, which Tm value differences were about 1 °C to each other. The melting curves of intra-assay reproducibility were almost coincided, and those of inter-assay reproducibility were much the same shape. The lowest detection concentration was about 5 × 10(-6)-ng/μL sample. The genotyping results from 21 G. lamblia samples by the HRM method were in complete accordance with sequencing results. It is concluded that the HRM genotyping method is rapid, stable, specific, highly sensitive, and suitable for clinical detection and molecular epidemiological survey of dog-derived G. lamblia.

  11. AO–MW–PLS method applied to rapid quantification of teicoplanin with near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Jiemei Chen

    2017-01-01

    Full Text Available Teicoplanin (TCP is an important lipoglycopeptide antibiotic produced by fermenting Actinoplanes teichomyceticus. The change in TCP concentration is important to measure in the fermentation process. In this study, a reagent-free and rapid quantification method for TCP in the TCP–Tris–HCl mixture samples was developed using near-infrared (NIR spectroscopy by focusing our attention on the fermentation process for TCP. The absorbance optimization (AO partial least squares (PLS was proposed and integrated with the moving window (MW PLS, which is called AO–MW–PLS method, to select appropriate wavebands. A model set that includes various wavebands that were equivalent to the optimal AO–MW–PLS waveband was proposed based on statistical considerations. The public region of all equivalent wavebands was just one of the equivalent wavebands. The obtained public regions were 1540–1868nm for TCP and 1114–1310nm for Tris. The root-mean-square error and correlation coefficient for leave-one-out cross validation were 0.046mg mL−1 and 0.9998mg mL−1 for TCP, and 0.235mg mL−1 and 0.9986mg mL−1 for Tris, respectively. All the models achieved highly accurate prediction effects, and the selected wavebands provided valuable references for designing specialized spectrometers. This study provided a valuable reference for further application of the proposed methods to TCP fermentation broth and to other spectroscopic analysis fields.

  12. Rapid, Simple, and Sensitive Spectrofluorimetric Method for the Estimation of Ganciclovir in Bulk and Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Garima Balwani

    2013-01-01

    Full Text Available A new, simple, rapid, sensitive, accurate, and affordable spectrofluorimetric method was developed and validated for the estimation of ganciclovir in bulk as well as in marketed formulations. The method was based on measuring the native fluorescence of ganciclovir in 0.2 M hydrochloric acid buffer of pH 1.2 at 374 nm after excitation at 257 nm. The calibration graph was found to be rectilinear in the concentration range of 0.25–2.00 μg mL−1. The limit of quantification and limit of detection were found to be 0.029 μg mL−1 and 0.010 μg mL−1, respectively. The method was fully validated for various parameters according to ICH guidelines. The results demonstrated that the procedure is accurate, precise, and reproducible (relative standard deviation <2% and can be successfully applied for the determination of ganciclovir in its commercial capsules with average percentage recovery of 101.31 ± 0.90.

  13. Rapid maxillary expansion effects: An alternative assessment method by means of cone-beam tomography

    Directory of Open Access Journals (Sweden)

    Camilo Aquino Melgaço

    2014-10-01

    Full Text Available INTRODUCTION: This study aims to develop a method to assess the changes in palatal and lingual cross-sectional areas in patients submitted to rapid maxillary expansion (RME. METHODS: The sample comprised 31 Class I malocclusion individuals submitted to RME and divided into two groups treated with Haas (17 patients and Hyrax (14 patients expanders. Cone-beam computed tomography scans were acquired at T0 (before expansion and T1 (six months after screw stabilization. Maxillary and mandibular cross-sectional areas were assessed at first permanent molars and first premolars regions and compared at T0 and T1. Mandibular occlusal area was also analyzed. RESULTS: Maxillary cross-sectional areas increased in 56.18 mm2 and 44.32 mm2 for the posterior and anterior regions. These values were smaller for the mandible, representing augmentation of 40.32 mm2 and 39.91 mm2 for posterior and anterior sections. No differences were found when comparing both expanders. Mandibular occlusal area increased 43.99mm2 and mandibular incisors proclined. Increments of 1.74 mm and 1.7 mm occurred in mandibular intermolar and interpremolar distances. These same distances presented increments of 5.5 mm and 5.57 mm for the maxillary arch. CONCLUSION: Occlusal and cross-sectional areas increased significantly after RME. The method described seems to be reliable and precise to assess intraoral area changes.

  14. Development of a new rapid HPLC method for the fractionation of histones

    International Nuclear Information System (INIS)

    Gurley, L.R.; Valdez, J.G.; Prentice, D.A.; Spall, W.D.

    1983-01-01

    To study histone functions, it is necessary to fractionate the histones into their five classes (H1, H2A, H2B, H3 and H4) and then to subfractionate these classes into variants having slightly different primary structures and into different phosphorylated and acetylated forms. With the advent of high-performance liquid chromatography (HPLC), it was hoped that laborious and time-consuming conventional methods could be replaced by a simple, rapid, high-resolving HPLC method for fractionating histones. However, problems of irreversible adsorption of the histones to HPLC column packings discouraged this development. Our laboratory has now determined that the strong adsorption of histones to HPLC columns results from two different forces: (1) polar interactions between the histones and the silanol groups of silica-based HPLC column packing, and (2) hydrophobic interactions between the histones and the bound organic phase of the column packings. By minimizing these forces, we have succeeded in developing an HPLC method suitable for histone studies

  15. Study on a noninvasive method for rapid screening Human Serum albumin injectables by Raman spectroscopy

    Directory of Open Access Journals (Sweden)

    Yu Zhao

    2017-01-01

    Full Text Available Human serum albumin (HSA injectable product is a severely afflicted area on drug safety due to its high price and restricted supply. Raman spectroscopy performances high specificity on HSA detection and it is even possible to determine HSA injectable products noninvasively. In this study, we developed a noninvasive rapid screening method for of HSA injectable products by using portable Raman spectrometer. Qualitative models were established by using principal component analysis combined with classical least squares (PCA-CLS algorithm, while quantitative model was established by using partial least squares (PLS algorithm. Model transfer in different instruments of both the same and different apparatus modules was further discussed in this paper. A total of 34 HSA injectable samples collected from markets were used for verification. The identification results showed 100% accuracy and the predicted concentrations of those identified as true HSA were consistent with their labeled concentrations. The quantitative results also indicated that model transfer was excellent in the same apparatus modules of Raman spectrometer at all concentration levels, and still good enough in the different apparatus modules although the relative standard deviation (RSD value showed a little increasing trend at low HSA concentration level. In conclusion, the method was proved to be feasible and efficient for screening HSA injections, especially on its screening speed and the consideration of glass containers. Moreover, with inspiring results on the model transfer, the method could be used as a universal screening mean to different Raman instruments.

  16. A precise, efficient radiometric assay for bacterial growth

    International Nuclear Information System (INIS)

    Boonkitticharoen, V.; Ehrhardt, C.; Kirchner, P.T.

    1984-01-01

    The two-compartment radiometric assay for bacterial growth promised major advantages over systems in clinical use, but poor reproducibility and counting efficiency limited its application. In this method, 14-CO/sub 2/ produced by bacterial metabolism of C-14-glucose is trapped and counted on filter paper impregnated with NaOH and fluors. The authors sought to improve assay efficiency and precision through a systematic study of relevant physical and chemical factors. Improvements in efficiency (88% vs. 10%) and in precision (relative S.D. 5% vs. 40%) were produced by a) reversing growth medium and scintillator chambers to permit vigorous agitation, b) increasing NaOH quantity and using a supersaturated PPO solution and c) adding detergent to improve uniformity of NaOH-PPO mixture. Inoculum size, substrate concentration and O/sub 2/ transfer rate affected assay sensitivity but not bacterial growth rate. The authors' assay reliably detects bacterial growth for inocula of 10,000 organisms in 1 hour and for 25 organisms within 4 1/2 hours, thus surpassing other existing clinical and research methods

  17. Iodine sorption of bentonite - radiometric and polarographic study

    International Nuclear Information System (INIS)

    Konirova, R.; Vinsova, H.; Koudelkova, M.; Ernestova, M.; Jedinakova-Krizova, V.

    2003-01-01

    The experiments focused on kinetics of iodine retardation on bentonite, influence of aqueous phase pH, buffering properties of bentonite, etc. were carried out by batch method. Distribution coefficient KD was the criterion applied for evaluation of iodine interaction with solid phase. High sorption potential of bentonite to cationic forms of various radionuclides, resulting from relatively high cation exchange capacity, is generally known. On the other hand the inorganic anions are not adsorbed strongly to mineral surface of clays thus uptake of iodine (occurring mainly at iodide (I - ) or iodate (IO 3 - ) form under oxoic conditions) is limited. The distribution coefficients of iodine anions' sorption on bentonite R reach order of magnitude 10 -1 mL/g. In order to increase the sorption capacity of the solid phase, several additives were added to bentonite. Most of them didn't provide satisfactory results except of the addition of activated carbon, which has high surface area. Electromigration and polarographic methods were used for investigation of the redox state of iodine in aqueous phase and determination of KD values as well. Acquired results were compared with data obtained by radiometric measurements. (authors)

  18. A Rapid Method for Quantifying Viable Mycobacterium avium subsp. paratuberculosis in Cellular Infection Assays

    Science.gov (United States)

    Pooley, Hannah B.; de Silva, Kumudika; Purdie, Auriol C.; Begg, Douglas J.; Whittington, Richard J.

    2016-01-01

    ABSTRACT Determining the viability of bacteria is a key outcome of in vitro cellular infection assays. Currently, this is done by culture, which is problematic for fastidious slow-growing bacteria such as Mycobacterium avium subsp. paratuberculosis, where it can take up to 4 months to confirm growth. This study aimed to identify an assay that can rapidly quantify the number of viable M. avium subsp. paratuberculosis cells in a cellular sample. Three commercially available bacterial viability assays along with a modified liquid culture method coupled with high-throughput quantitative PCR growth detection were assessed. Criteria for assessment included the ability of each assay to differentiate live and dead M. avium subsp. paratuberculosis organisms and their accuracy at low bacterial concentrations. Using the culture-based method, M. avium subsp. paratuberculosis growth was reliably detected and quantified within 2 weeks. There was a strong linear association between the 2-week growth rate and the initial inoculum concentration. The number of viable M. avium subsp. paratuberculosis cells in an unknown sample was quantified based on the growth rate, by using growth standards. In contrast, none of the commercially available viability assays were suitable for use with samples from in vitro cellular infection assays. IMPORTANCE Rapid quantification of the viability of Mycobacterium avium subsp. paratuberculosis in samples from in vitro cellular infection assays is important, as it allows these assays to be carried out on a large scale. In vitro cellular infection assays can function as a preliminary screening tool, for vaccine development or antimicrobial screening, and also to extend findings derived from experimental animal trials. Currently, by using culture, it takes up to 4 months to obtain quantifiable results regarding M. avium subsp. paratuberculosis viability after an in vitro infection assay; however, with the quantitative PCR and liquid culture method

  19. Validity and feasibility of a satellite imagery-based method for rapid estimation of displaced populations.

    Science.gov (United States)

    Checchi, Francesco; Stewart, Barclay T; Palmer, Jennifer J; Grundy, Chris

    2013-01-23

    Estimating the size of forcibly displaced populations is key to documenting their plight and allocating sufficient resources to their assistance, but is often not done, particularly during the acute phase of displacement, due to methodological challenges and inaccessibility. In this study, we explored the potential use of very high resolution satellite imagery to remotely estimate forcibly displaced populations. Our method consisted of multiplying (i) manual counts of assumed residential structures on a satellite image and (ii) estimates of the mean number of people per structure (structure occupancy) obtained from publicly available reports. We computed population estimates for 11 sites in Bangladesh, Chad, Democratic Republic of Congo, Ethiopia, Haiti, Kenya and Mozambique (six refugee camps, three internally displaced persons' camps and two urban neighbourhoods with a mixture of residents and displaced) ranging in population from 1,969 to 90,547, and compared these to "gold standard" reference population figures from census or other robust methods. Structure counts by independent analysts were reasonably consistent. Between one and 11 occupancy reports were available per site and most of these reported people per household rather than per structure. The imagery-based method had a precision relative to reference population figures of layout. For each site, estimates were produced in 2-5 working person-days. In settings with clearly distinguishable individual structures, the remote, imagery-based method had reasonable accuracy for the purposes of rapid estimation, was simple and quick to implement, and would likely perform better in more current application. However, it may have insurmountable limitations in settings featuring connected buildings or shelters, a complex pattern of roofs and multi-level buildings. Based on these results, we discuss possible ways forward for the method's development.

  20. Improved Savitzky-Golay-method-based fluorescence subtraction algorithm for rapid recovery of Raman spectra.

    Science.gov (United States)

    Chen, Kun; Zhang, Hongyuan; Wei, Haoyun; Li, Yan

    2014-08-20

    In this paper, we propose an improved subtraction algorithm for rapid recovery of Raman spectra that can substantially reduce the computation time. This algorithm is based on an improved Savitzky-Golay (SG) iterative smoothing method, which involves two key novel approaches: (a) the use of the Gauss-Seidel method and (b) the introduction of a relaxation factor into the iterative procedure. By applying a novel successive relaxation (SG-SR) iterative method to the relaxation factor, additional improvement in the convergence speed over the standard Savitzky-Golay procedure is realized. The proposed improved algorithm (the RIA-SG-SR algorithm), which uses SG-SR-based iteration instead of Savitzky-Golay iteration, has been optimized and validated with a mathematically simulated Raman spectrum, as well as experimentally measured Raman spectra from non-biological and biological samples. The method results in a significant reduction in computing cost while yielding consistent rejection of fluorescence and noise for spectra with low signal-to-fluorescence ratios and varied baselines. In the simulation, RIA-SG-SR achieved 1 order of magnitude improvement in iteration number and 2 orders of magnitude improvement in computation time compared with the range-independent background-subtraction algorithm (RIA). Furthermore the computation time of the experimentally measured raw Raman spectrum processing from skin tissue decreased from 6.72 to 0.094 s. In general, the processing of the SG-SR method can be conducted within dozens of milliseconds, which can provide a real-time procedure in practical situations.

  1. Recent advances in airborne radiometric technology

    International Nuclear Information System (INIS)

    Jobst, J.E.

    1985-01-01

    Since its inception, the DOE Remote Sensing Laboratory has made dramatic innovations in airborne radiometric technology. In the past few years there have been at least four major changes in operational philosophy. (1) The helicopter is now the prime radiation survey vehicle. Surveys are conducted at low speed and low altitude, with lines spaced only a few hundred feet apart. Radiation anomalies and subtle changes in background can be readily identified. (2) Much greater emphasis is now placed on accurate, detailed analysis and interpretation of radiation data. Dramatic improvements in survey hardware and software provide much more data of considerably better quality. (3) Recent Laboratory research has been concentrated on error-free, positive identification of point radiation sources. In the past, the extent and magnitude of dispersed sources were the major concerns. (4) Integrated remote sensing has been strongly emphasized at the Laboratory in recent years. This involves the simultaneous use of radiation detectors, aerial cameras, and the multispectral scanner imagery. The synergistic effects of such data correlation are of significantly greater value in analyzing the terrestrial environment. Many of the changes in operational philosophy are directly traceable to new or dramatically improved hardware and software employed at the Laboratory. Six items have been instrumental in the above technological advances: (1) the UHF Transponder System and its predecessor, the Microwave Ranging System; (2) Model IC of the REDAR data acquisition system; (3) the development of the search algorithm; (4) continued improvements in the REDACA data analysis system; (5) deployment of polyscin sodium iodide radiation detectors; and (6) development of the Graphic Overview System

  2. Rapid Methods to Distinguish Heterodera schachtii from Heterodera glycines Using PCR Technique

    Directory of Open Access Journals (Sweden)

    Hyoung Rai Ko

    2017-09-01

    Full Text Available The purpose of this study was to develop rapid methods for distinguishing between Heterodera schachtii and H. glycines detected from chinese cabbage fields of highland in Gangwon, Korea. To do this, we performed PCR-RFLP and PCR with the primers set developed in this study for GC147, GC408 and PM001 population, H. schachtii, and YS224, DA142 and BC115 population, H. glycines. Eight restriction enzymes generated RFLP profiles of mtDNA COI region for populations of H. schachtii and H. glycines, repectively. As a result, treatment of two restriction enzymes, RsaI and HinfI, were allowed to distinguish H. schachtii from H. glycines based on the differences of DNA band patterns. The primer set, #JBS1, #JBG1 and #JB3R, amplified specific fragments with 277 and 339 bp of H. schachtii, 339 bp of H. glycines, respectively, while it did not amplify fragments from three root-knot nematodes and two root-lesion nematodes. Thus, the primer set developed in this study could be a good method, which is used to distinguish between H. schachtii and H. glycines.

  3. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  4. Rapid processing method for solution deposited YBa2Cu3O7-δ thin films

    International Nuclear Information System (INIS)

    Dawley, J.T.; Clem, P.G.; Boyle, T.J.; Ottley, L.M.; Overmyer, D.L.; Siegal, M.P.

    2004-01-01

    YBa 2 Cu 3 O 7-δ (YBCO) films, deposited on buffered metal substrates, are the primary candidate for second-generation superconducting (SC) wires, with applications including expanded power grid transmission capability, compact motors, and enhanced sensitivity magnetic resonance imaging. Feasibility of manufacturing such superconducting wires is dependent on high processing speed, often a limitation of vapor and solution-based YBCO deposition processes. In this work, YBCO films were fabricated via a new diethanolamine-modified trifluoroacetic film solution deposition method. Modifying the copper chemistry of the YBCO precursor solution with diethanolamine enables a hundredfold decrease in the organic pyrolysis time required for MA/cm 2 current density (J c ) YBCO films, from multiple hours to ∼20 s in atmospheric pressure air. High quality, ∼0.2 μm thick YBCO films with J c (77 K) values ≥2 MA/cm 2 at 77 K are routinely crystallized from these rapidly pyrolyzed films deposited on LaAlO 3 . This process has also enabled J c (77 K)=1.1 MA/cm 2 YBCO films via 90 m/h dip-coating on Oak Ridge National Laboratory RABiTS textured metal tape substrates. This new YBCO solution deposition method suggests a route toward inexpensive and commercializable ∼$10/kA m solution deposited YBCO coated conductor wires

  5. Comparing rapid and culture indicator bacteria methods at inland lake beaches

    Science.gov (United States)

    Francy, Donna S.; Bushon, Rebecca N.; Brady, Amie M.G.; Kephart, Christopher M.

    2013-01-01

    A rapid method, quantitative polymerase chain reaction (qPCR), for quantifying indicator bacteria in recreational waters is desirable for public health protection. We report that replacing current Escherichia coli standards with new US Environmental Protection Agency beach action values (BAVs) for enterococci by culture or qPCR may result in more advisories being posted at inland recreational lakes. In this study, concentrations of E. coli and enterococci by culture methods were compared to concentrations of Enterococcus spp. by qPCR at 3 inland lake beaches in Ohio. The E. coli and enterococci culture results were significantly related at all beaches; however, the relations between culture results and Enterococcus spp. qPCR results were not always significant and differed among beaches. All the qPCR results exceeded the new BAV for Enterococcus spp. by qPCR, whereas only 23.7% of culture results for E. coli and 79% of culture results for enterococci exceeded the current standard for E. coli or BAV for enterococci.

  6. Development of a Rapid and Simple Method to Remove Polyphenols from Plant Extracts

    Directory of Open Access Journals (Sweden)

    Imali Ranatunge

    2017-01-01

    Full Text Available Polyphenols are secondary metabolites of plants, which are responsible for prevention of many diseases. Polyvinylpolypyrrolidone (PVPP has a high affinity towards polyphenols. This method involves the use of PVPP column to remove polyphenols under centrifugal force. Standards of gallic acid, epigallocatechin gallate, vanillin, and tea extracts (Camellia sinensis were used in this study. PVPP powder was packed in a syringe with different quantities. The test samples were layered over the PVPP column and subjected to centrifugation. Supernatant was tested for the total phenol content. The presence of phenolic compounds and caffeine was screened by HPLC and measuring the absorbance at 280. The antioxidant capacity of standards and tea extracts was compared with the polyphenol removed fractions using DPPH scavenging assay. No polyphenols were found in polyphenolic standards or tea extracts after PVPP treatment. The method described in the present study to remove polyphenols is simple, inexpensive, rapid, and efficient and can be employed to investigate the contribution of polyphenols present in natural products to their biological activity.

  7. New multiplex PCR methods for rapid screening of genetically modified organisms in foods

    Directory of Open Access Journals (Sweden)

    Nelly eDatukishvili

    2015-07-01

    Full Text Available We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs. New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products.

  8. A novel method for rapid comparative quantitative analysis of nuclear fuel cycles

    International Nuclear Information System (INIS)

    Eastham, Sebastian D.; Coates, David J.; Parks, Geoffrey T.

    2012-01-01

    Highlights: ► Metric framework determined to compare nuclear fuel cycles. ► Fast and thermal reactors simulated using MATLAB models, including thorium. ► Modelling uses deterministic methods instead of Monte–Carlo for speed. ► Method rapidly identifies relative cycle strengths and weaknesses. ► Significant scope for use in project planning and cycle optimisation. - Abstract: One of the greatest obstacles facing the nuclear industry is that of sustainability, both in terms of the finite reserves of uranium ore and the production of highly radiotoxic spent fuel which presents proliferation and environmental hazards. Alternative nuclear technologies have been suggested as a means of delivering enhanced sustainability with proposals including fast reactors, the use of thorium fuel and tiered fuel cycles. The debate as to which is the most appropriate technology continues, with each fuel system and reactor type delivering specific advantages and disadvantages which can be difficult to compare fairly. This paper demonstrates a framework of performance metrics which, coupled with a first-order lumped reactor model to determine nuclide population balances, can be used to quantify the aforementioned pros and cons for a range of different fuel and reactor combinations. The framework includes metrics such as fuel efficiency, spent fuel toxicity and proliferation resistance, and relative cycle performance is analysed through parallel coordinate plots, yielding a quantitative comparison of disparate cycles.

  9. A rapid and quantitative method to determine the tritium content in DNA from small tissue sampes

    International Nuclear Information System (INIS)

    Kasche, V.; Zoellner, R.

    1979-01-01

    A rapid and quantitative two-step procedure to isolate double-strand DNA from small (10-100 mg) animal tissue samples is presented. The method is developed for investigations to evaluate the relative importance of organically bound tritium for the dose factors used to calculate dose commitments due to this nuclide. In the first step the proteins in the homogenized sample are hydrolysed, at a high pH (9.0) and ionic strength (1.5) to dissociate protein from DNA, using immobilized Proteinase K as a proteolytic enzyme. The DNA is then absorbed to hydroxylapatite and separated from impurities by step-wise elution with buffers of increasing ionic strength. More than 90% of the DNA in the samples could be isolated in double-strand form by this procedure. The method has been applied to determine pool-sizes and biological half-life times of tritium in DNA from various animal (mouse) tissues. It has also been shown to be suitable in other radiobiological studies where effects on DNA are investigated. (author)

  10. Method for rapid particle size analysis by hydrosizing and nuclear sensing

    International Nuclear Information System (INIS)

    Daellenbach, C.B.; Mahan, W.M.

    1977-01-01

    A method and apparatus to practice the method for rapidly determining the size and mass distribution of a sample of randomly sized particles of a known total mass are described. A series of substantially identical hydrocyclones are connected by conduits to each other and to a temperature controlled water feed. By restricting the cross-sectional areas of these conduits to progressively smaller values, the slurry containing the sample particles is caused to increase its velocity as it moves from hydrocyclone to hydrocyclone. As described by the Stokesian theory which relates particle diameter and settling velocity, the largest sized particles are suspended in the closed apex of the first hydrocyclone with smaller sized particles, in given size ranges, being suspended in the next succeeding hydrocyclone's apexes. In this manner, the particles are separated into discrete fractional sizes with a residual slurry of the very smallest particles being discharged. Before the discrete fractions of particles are suspended in their hydrocyclone apexes, a combined photon source, like a gamma ray source, and detector are calibrated with the water temperature kept constant. When the suspension of particles takes place, an attenuation of the radiation from the source is observed at the detector. This attenuation can be related to the mass or weight of the discrete fractions of suspended particles. Electronic circuitry is used to indicate what this fractional mass or weight is as it relates to the total weight of the sample. 6 claims, 4 figs

  11. New multiplex PCR methods for rapid screening of genetically modified organisms in foods.

    Science.gov (United States)

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products.

  12. Rapid Separation Methods to Characterize Actinides and Metallic Impurities in Plutonium Scrap Materials at SRS

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Jones, V.D.

    1998-07-01

    The Nuclear Materials Stabilization and Storage Division at SRS plans to stabilize selected plutonium scrap residue materials for long term storage by dissolution processing and plans to stabilize other plutonium vault materials via high-temperature furnace processing. To support these nuclear material stabilization activities, the SRS Analytical Laboratories Department (ALD) will provide characterization of materials required prior to the dissolution or the high-firing of these materials. Lab renovations to install new analytical instrumentation are underway to support these activities that include glove boxes with simulated-process dissolution and high- pressure microwave dissolution capability. Inductively-coupled plasma atomic emission spectrometry (ICP-AES), inductively- coupled mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) will be used to measure actinide isotopics and metallic impurities. New high-speed actinide separation methods have been developed that will be applied to isotopic characterization of nuclear materials by TIMS and ICP-MS to eliminate isobaric interferences between Pu-238 /U- 238 and Pu-241/Am-241. TEVA Resin, UTEVA Resin, and TRU Resin columns will be used with vacuum-assisted flow rates to minimize TIMS and ICP-MS sample turnaround times. For metallic impurity analysis, rapid column removal methods using UTEVA Resin, AGMP-1 anion resin and AG MP-50 cation resin have also been developed to remove plutonium and uranium matrix interferences prior to ICP-AES and ICP- MS measurements

  13. A method of LED free-form tilted lens rapid modeling based on scheme language

    Science.gov (United States)

    Dai, Yidan

    2017-10-01

    According to nonimaging optical principle and traditional LED free-form surface lens, a new kind of LED free-form tilted lens was designed. And a method of rapid modeling based on Scheme language was proposed. The mesh division method was applied to obtain the corresponding surface configuration according to the character of the light source and the desired energy distribution on the illumination plane. Then 3D modeling software and the Scheme language programming are used to generate lens model respectively. With the help of optical simulation software, a light source with the size of 1mm*1mm*1mm in volume is used in experiment, and the lateral migration distance of illumination area is 0.5m, in which total one million rays are computed. We could acquire the simulated results of both models. The simulated output result shows that the Scheme language can prevent the model deformation problems caused by the process of the model transfer, and the degree of illumination uniformity is reached to 82%, and the offset angle is 26°. Also, the efficiency of modeling process is greatly increased by using Scheme language.

  14. Polymerase Chain Reaction/Rapid Methods Are Gaining a Foothold in Developing Countries.

    Science.gov (United States)

    Ragheb, Suzan Mohammed; Jimenez, Luis

    Detection of microbial contamination in pharmaceutical raw materials and finished products is a critical factor to guarantee their safety, stability, and potency. Rapid microbiological methods-such as polymerase chain reaction-have been widely applied to clinical and food quality control analysis. However, polymerase chain reaction applications to pharmaceutical quality control have been rather slow and sporadic. Successful implementation of these methods in pharmaceutical companies in developing countries requires important considerations to provide sensitive and robust assays that will comply with good manufacturing practices. In recent years several publications have encouraged the application of molecular techniques in the microbiological assessment of pharmaceuticals. One of these techniques is polymerase chain reaction (PCR). The successful application of PCR in the pharmaceutical industry in developing countries is governed by considerable factors and requirements. These factors include the setting up of a PCR laboratory and the choice of appropriate equipment and reagents. In addition, the presence of well-trained analysts and establishment of quality control and quality assurance programs are important requirements. The pharmaceutical firms should take into account these factors to allow better chances for regulatory acceptance and wide application of this technique. © PDA, Inc. 2014.

  15. Geologic and radiometric study in the Picacho, Arizpe's Municipality, Sorora (Mexico) area

    International Nuclear Information System (INIS)

    Garcia y Barragan, J.C.

    1975-01-01

    This research work was aimed chiefly at studying the geology and radiometry of the El Picacho area in order to establish its uranium mineralization potential. Another purpose was to ascertain the factors favouring deposition of radioactive material in areas bordering on the Sierra del Manzanal, where the work was carried out. Detailed geological-radiometric surveys were made, both inside the El Picacho mine and at the surface. The geological surveys were carried out by means of compass bearings and stadia, while scintillometers and spectrometers were used for the radiometric studies. The work was supported by a general geological exploration of the central part of the Serra del Manzanal. To ascertain the radiometric anomalies, the distribution of the population of values was determined by statistical methods, the frequency, cumulative frequency and frequency percentage being evaluated for that purpose. The geological survey at the El Picacho mine revealed a group of fractures enclosing the following minerals: torbernite, iriginite and autunite. These fractures are no thicker than 5 cm and tend to wedge out after 3 meters. Primary uraniferous ore is likely to be found in this zone, so surveys based on (a) radon gas emanometry and (b) sediment geochemistry in the Siera del Manzanal are recommended. The basic data relating to this area could be supplemented by mineragraphic and X-ray studies, which would provide a fuller picture of the class of mineralogical species and of the paragenesis of radioactive material presnent in the zone. (author)

  16. Synoptic view of the different domains of application of airborne radiometric and spectrometric surveys in egypt

    International Nuclear Information System (INIS)

    Fouad, K.M.

    1998-01-01

    Airborne radiometric survey has been applied for more than three decades in egypt. Experience gained from the acquired data over different geological environments has revealed the importance of this geophysical tool in: 1. disclosure of anomalies of potential uranium deposits, 2. geological mapping, 3. environmental monitoring of natural radiometric background around nuclear facilities, as well as the detection of nuclear fallout resulting from local or foreign nuclear activities. The advent of recording of the discriminated gamma ray energies in the airborne 256-channel spectrometer has eventually resulted in the quantitative detection of uranium, thorium, and potassium and their elemental ratios in the rocks. This has greatly widened the scope of geophysical and geochemical application. When this type is coupled with airborne magnetometry, the geological and structural configuration is appreciably revealed in three dimensions. The important role played by the statistical method of analysis is also shown. Case histories from the eastern desert, and sinai peninsula, are exhibited to help manifest the wide variety of applications of radiometric and spectrometric surveys

  17. Radiometric determination of uniformity of putting paraffin on textile threads

    International Nuclear Information System (INIS)

    Ridel', Z.; Kherrmann, Eh.; Shefer, I.; Tseiner, A.

    1979-01-01

    To improve processing of the natural and synthetic fiber threads on stocking-frames, they are treated by paraffin. Paraffin is applied in the amounts nearly equal to 0.1 -1.0 g for 10 4 m of the thread's length. To determine amount of paraffin on thread and to determine uniformity if its application, a radiometric method has been developed. As a radioactive label, didocilephosphate of rare earths was used. This compound has good solubility in hydrocarbons and does not change physical properties of paraffin in the investigated field of its application as well as its concentration. It is possible to add to paraffin this radioactive label or a non-active label with subsequent its activation. Amount of paraffin, applied on a thread is determined by means of measurement of activity of thread samples of different length. Information about uniformity of paraffin application on thread have been obtained by means of autoradiography. It has been found that paraffin in mainly applied on the thread's bulges [ru

  18. Noninvasive Hemoglobin Monitoring: A Rapid, Reliable, and Cost-Effective Method Following Total Joint Replacement.

    Science.gov (United States)

    Martin, J Ryan; Camp, Christopher L; Stitz, Amber; Young, Ernest Y; Abdel, Matthew P; Taunton, Michael J; Trousdale, Robert T

    2016-03-02

    Noninvasive hemoglobin (nHgb) monitoring was initially introduced in the intensive care setting as a means of rapidly assessing Hgb values without performing a blood draw. We conducted a prospective analysis to compare reliability, cost, and patient preference between nHgb monitoring and invasive Hgb (iHgb) monitoring performed via a traditional blood draw. We enrolled 100 consecutive patients undergoing primary or revision total hip or total knee arthroplasty. On postoperative day 1, nHgb and iHgb values were obtained within thirty minutes of one another. iHgb and nHgb values, cost, patient satisfaction, and the duration of time required to obtain each reading were recorded. The concordance correlation coefficient (CCC) was utilized to evaluate the agreement of the two Hgb measurement methods. Paired t tests and Wilcoxon signed-rank tests were utilized to compare mean Hgb values, time, and pain for all readings. The mean Hgb values did not differ significantly between the two measurement methods: the mean iHgb value (and standard deviation) was 11.3 ± 1.4 g/dL (range, 8.2 to 14.3 g/dL), and the mean nHgb value was 11.5 ± 1.8 g/dL (range, 7.0 to 16.0 g/dL) (p = 0.11). The CCC between the two Hgb methods was 0.69. One hundred percent of the patients with an nHgb value of ≥ 10.5 g/dL had an iHgb value of >8.0 g/dL. The mean time to obtain an Hgb value was 0.9 minute for the nHgb method and 51.1 minutes for the iHgb method (p measurement, resulting in a savings of $26 per Hgb assessment when the noninvasive method is used. Noninvasive Hgb monitoring was found to be more efficient, less expensive, and preferred by patients compared with iHgb monitoring. Providers could consider screening total joint arthroplasty patients with nHgb monitoring and only order iHgb measurement if the nHgb value is protocol had been applied to the first blood draw in our 100 patients, approximately $2000 would have been saved. Extrapolated to the U.S. total joint arthroplasty practice

  19. Crossing Methods and Cultivation Conditions for Rapid Production of Segregating Populations in Three Grain Amaranth Species.

    Science.gov (United States)

    Stetter, Markus G; Zeitler, Leo; Steinhaus, Adrian; Kroener, Karoline; Biljecki, Michelle; Schmid, Karl J

    2016-01-01

    Grain amaranths (Amaranthus spp.) have been cultivated for thousands of years in Central and South America. Their grains are of high nutritional value, but the low yield needs to be increased by selection of superior genotypes from genetically diverse breeding populations. Amaranths are adapted to harsh conditions and can be cultivated on marginal lands although little is known about their physiology. The development of controlled growing conditions and efficient crossing methods is important for research on and improvement of this ancient crop. Grain amaranth was domesticated in the Americas and is highly self-fertilizing with a large inflorescence consisting of thousands of very small flowers. We evaluated three different crossing methods (open pollination, hot water emasculation and hand emasculation) for their efficiency in amaranth and validated them with genetic markers. We identified cultivation conditions that allow an easy control of flowering time by day length manipulation and achieved flowering times of 4 weeks and generation times of 2 months. All three different crossing methods successfully produced hybrid F1 offspring, but with different success rates. Open pollination had the lowest (10%) and hand emasculation the highest success rate (74%). Hot water emasculation showed an intermediate success rate (26%) with a maximum of 94% success. It is simple to perform and suitable for a more large-scale production of hybrids. We further evaluated 11 single nucleotide polymorphism (SNP) markers and found that they were sufficient to validate all crosses of the genotypes used in this study for intra- and interspecific hybridizations. Despite its very small flowers, crosses in amaranth can be carried out efficiently and evaluated with inexpensive SNP markers. Suitable growth conditions strongly reduce the generation time and allow the control of plant height, flowering time, and seed production. In combination, this enables the rapid production of segregating

  20. A new rapid method to measure human platelet cholesterol: a pilot study.

    Science.gov (United States)

    Jagroop, I Anita; Persaud, Jahm Want; Mikhailidis, Dimitri P

    2011-01-01

    Platelet cholesterol (PC) could be used to assess "tissue" cholesterol of patients with vascular disease. However, the methods available so far to measure PC involve a complex extraction process. We developed a rapid method to measure PC and assessed its correlation with serum total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), LDL-C/HDL-C ratio, triglycerides (TG), and non-HDL-C. We assessed repeatability (20 times, 3 participants) and reproducibility (8 times, 2 participants). A group of 47 healthy participants was studied. Blood was collected to analyze serum TC, LDL-C, HDL-C, and TG. Citrated blood was used to prepare a platelet pellet. A "clear soup" was produced (by disrupting this pellet using freeze-thaw and sonication cycles) and used to measure PC. Repeatability of PC showed a coefficient of variation (CV) of 4.8%. The reproducibility of PC over a period of 2 months was CV 7.5% and 8.1% (8 measurements for 2 participants). The PC of participants with serum LDL-C >2.6 mmol/L (treatment goal recommended by the National Cholesterol Education Program Adult Treatment Panel III) was 377 ± 120 μmol/10(12) platelets (n = 25). There was a significant correlation (Spearman, correlation coefficient) of PC (n = 25) with serum LDL-C (r(s) = 0.45, P = .02), LDL-C/HDL-C (r(s) = 0.45, P = .02), TG (r(s) = 0.43, P = .03), and non-HDL-C (r(s) = 0.53, P = .007). This technique of measuring PC has the advantage of being reproducible, fast, and simpler than previous methods. Thus, it may be useful for multiple sampling when investigating changes in PC in hypercholesterolemic patients. More extensive evaluation is necessary.

  1. Deep Space Network Radiometric Remote Sensing Program

    Science.gov (United States)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  2. Development of a rapid method for the quantitative determination of deoxynivalenol using Quenchbody

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinari, Tomoya [Division of Microbiology, National Institute of Health Sciences, 1-18-1, Kamiyoga, Setagaya-ku, Tokyo 158-8501 (Japan); Ohashi, Hiroyuki; Abe, Ryoji; Kaigome, Rena [Biomedical Division, Ushio Inc., 1-12 Minamiwatarida-cho, Kawasaki-ku, Kawasaki 210-0855 (Japan); Ohkawa, Hideo [Research Center for Environmental Genomics, Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Sugita-Konishi, Yoshiko, E-mail: y-konishi@azabu-u.ac.jp [Department of Food and Life Science, Azabu University, 1-17-71 Fuchinobe, Chuo-ku, Sagamihara, Kanagawa 252-5201 (Japan)

    2015-08-12

    Quenchbody (Q-body) is a novel fluorescent biosensor based on the antigen-dependent removal of a quenching effect on a fluorophore attached to antibody domains. In order to develop a method using Q-body for the quantitative determination of deoxynivalenol (DON), a trichothecene mycotoxin produced by some Fusarium species, anti-DON Q-body was synthesized from the sequence information of a monoclonal antibody specific to DON. When the purified anti-DON Q-body was mixed with DON, a dose-dependent increase in the fluorescence intensity was observed and the detection range was between 0.0003 and 3 mg L{sup −1}. The coefficients of variation were 7.9% at 0.003 mg L{sup −1}, 5.0% at 0.03 mg L{sup −1} and 13.7% at 0.3 mg L{sup −1}, respectively. The limit of detection was 0.006 mg L{sup −1} for DON in wheat. The Q-body showed an antigen-dependent fluorescence enhancement even in the presence of wheat extracts. To validate the analytical method using Q-body, a spike-and-recovery experiment was performed using four spiked wheat samples. The recoveries were in the range of 94.9–100.2%. The concentrations of DON in twenty-one naturally contaminated wheat samples were quantitated by the Q-body method, LC-MS/MS and an immunochromatographic assay kit. The LC-MS/MS analysis showed that the levels of DON contamination in the samples were between 0.001 and 2.68 mg kg{sup −1}. The concentrations of DON quantitated by LC-MS/MS were more strongly correlated with those using the Q-body method (R{sup 2} = 0.9760) than the immunochromatographic assay kit (R{sup 2} = 0.8824). These data indicate that the Q-body system for the determination of DON in wheat samples was successfully developed and Q-body is expected to have a range of applications in the field of food safety. - Highlights: • A rapid method for quantitation of DON using Q-body has been developed. • A recovery test using the anti-DON Q-body was performed. • The concentrations of DON in wheat

  3. A new quantitative method for the rapid evaluation of buildings against earthquakes

    International Nuclear Information System (INIS)

    Mahmoodzadeh, Amir; Mazaheri, Mohammad Mehdi

    2008-01-01

    At the present time there exist numerous weak buildings which are not able to withstand earthquakes. At the same time, both private and public developers are trying to use scientific methods to prioritize and allocate budget in order to reinforce the above mentioned structures. This is because of the limited financial resources and time. In the recent years the procedure of seismic assessment before rehabilitation of vulnerable buildings has been implemented in many countries. Now, it seems logical to reinforce the existing procedures with the mass of available data about the effects caused by earthquakes on buildings. The main idea is driven from FMEA (Failure Mode and Effect Analysis) in quality management where the main procedure is to recognize the failure, the causes, and the priority of each cause and failure. Specifying the causes and effects which lead to a certain shortcoming in structural behavior during earthquakes, an inventory is developed and each building is rated through a yes-or-no procedure. In this way, the rating of the structure is based on some standard forms which along with relative weights are developed in this study. The resulted criteria by rapid assessment will indicate whether the structure is to be demolished, has a high, medium or low vulnerability or is invulnerable

  4. A METHOD OF RAPID CULTIVATION OF RADISH SEED PLANTS IN PLASTIC POTS OF SMALL-VOLUME

    Directory of Open Access Journals (Sweden)

    V. A. Stepanov

    2017-01-01

    Full Text Available The development of cheap and rapid breeding methods to breed  the lines used for  hybrid  F1  production  is a very actual task. The study was carried out with a use of radish varieties originated at VNIISSOK and breeding lines obtained by crossing components of different origin with male  sterility  in  winter  glass  greenhouse.  The  mother plants were grown  on the trays Plantec 64, while seedplants were grown in plastic pots of 1 liter capacity. The some morphobiological features such as the small habitus of see-plant; smaller number of secondary branching and absence of following branches; and consequently, the low yield of seeds were revealed in seed-plants of radish being grown in plastic pots. The period of ontogenesis in radish at first winter-spring rotation with this cultivation approach was reduced to 92 days. At the second summer-autumn rotation with additional lighting the duration of period of ontogenesis was essentially shorter than in the first rotation.  The utilization of  small-volume capacities in winter glass greenhouse to grow the radish seed-plants has permitted to produce two generations a year.

  5. A Novel Rapid MALDI-TOF-MS-Based Method for Measuring Urinary Globotriaosylceramide in Fabry Patients

    Science.gov (United States)

    Alharbi, Fahad J.; Geberhiwot, Tarekegn; Hughes, Derralynn A.; Ward, Douglas G.

    2016-04-01

    Fabry disease is an X-linked lysosomal storage disorder caused by deficiency of α-galactosidase A, resulting in the accumulation of glycosphingolipids in various organs. Globotriaosylceramide (Gb3) and its isoforms and analogues have been identified and quantified as biomarkers of disease severity and treatment efficacy. The current study aimed to establish rapid methods for urinary Gb3 extraction and quantitation. Urine samples from 15 Fabry patients and 21 healthy control subjects were processed to extract Gb3 by mixing equal volumes of urine, methanol containing an internal standard, and chloroform followed by sonication and centrifugation. Thereafter, the lower phase was analyzed by MALDI-TOF MS and the relative peak areas of the internal standard and four major species of Gb3 determined. The results showed high reproducibility with intra- and inter-assay coefficients variation of 9.9% and 13.7%, respectively. The limit of detection was 0.15 ng/μL and the limit of quantitation was 0.30 ng/μL. Total urinary Gb3 levels in both genders of classic Fabry patients were significantly higher than in healthy controls (p < 0.0001). Gb3 levels in Fabry males were higher than in Fabry females (p = 0.08). We have established a novel assay for urinary total Gb3 that takes less than 15 min from start to finish.

  6. A Simple and Rapid Method for Preparing a Cell-Free Bacterial Lysate for Protein Synthesis.

    Directory of Open Access Journals (Sweden)

    Nitzan Krinsky

    Full Text Available Cell-free protein synthesis (CFPS systems are important laboratory tools that are used for various synthetic biology applications. Here, we present a simple and inexpensive laboratory-scale method for preparing a CFPS system from E. coli. The procedure uses basic lab equipment, a minimal set of reagents, and requires less than one hour to process the bacterial cell mass into a functional S30-T7 extract. BL21(DE3 and MRE600 E. coli strains were used to prepare the S30-T7 extract. The CFPS system was used to produce a set of fluorescent and therapeutic proteins of different molecular weights (up to 66 kDa. This system was able to produce 40-150 μg-protein/ml, with variations depending on the plasmid type, expressed protein and E. coli strain. Interestingly, the BL21-based CFPS exhibited stability and increased activity at 40 and 45°C. To the best of our knowledge, this is the most rapid and affordable lab-scale protocol for preparing a cell-free protein synthesis system, with high thermal stability and efficacy in producing therapeutic proteins.

  7. A Simple and Rapid Method for Preparing a Cell-Free Bacterial Lysate for Protein Synthesis

    Science.gov (United States)

    Kaduri, Maya; Shainsky-Roitman, Janna; Goldfeder, Mor; Ivanir, Eran; Benhar, Itai; Shoham, Yuval; Schroeder, Avi

    2016-01-01

    Cell-free protein synthesis (CFPS) systems are important laboratory tools that are used for various synthetic biology applications. Here, we present a simple and inexpensive laboratory-scale method for preparing a CFPS system from E. coli. The procedure uses basic lab equipment, a minimal set of reagents, and requires less than one hour to process the bacterial cell mass into a functional S30-T7 extract. BL21(DE3) and MRE600 E. coli strains were used to prepare the S30-T7 extract. The CFPS system was used to produce a set of fluorescent and therapeutic proteins of different molecular weights (up to 66 kDa). This system was able to produce 40–150 μg-protein/ml, with variations depending on the plasmid type, expressed protein and E. coli strain. Interestingly, the BL21-based CFPS exhibited stability and increased activity at 40 and 45°C. To the best of our knowledge, this is the most rapid and affordable lab-scale protocol for preparing a cell-free protein synthesis system, with high thermal stability and efficacy in producing therapeutic proteins. PMID:27768741

  8. Rapid characterization of transgenic and non-transgenic soybean oils by chemometric methods using NIR spectroscopy

    Science.gov (United States)

    Luna, Aderval S.; da Silva, Arnaldo P.; Pinho, Jéssica S. A.; Ferré, Joan; Boqué, Ricard

    Near infrared (NIR) spectroscopy and multivariate classification were applied to discriminate soybean oil samples into non-transgenic and transgenic. Principal Component Analysis (PCA) was applied to extract relevant features from the spectral data and to remove the anomalous samples. The best results were obtained when with Support Vectors Machine-Discriminant Analysis (SVM-DA) and Partial Least Squares-Discriminant Analysis (PLS-DA) after mean centering plus multiplicative scatter correction. For SVM-DA the percentage of successful classification was 100% for the training group and 100% and 90% in validation group for non transgenic and transgenic soybean oil samples respectively. For PLS-DA the percentage of successful classification was 95% and 100% in training group for non transgenic and transgenic soybean oil samples respectively and 100% and 80% in validation group for non transgenic and transgenic respectively. The results demonstrate that NIR spectroscopy can provide a rapid, nondestructive and reliable method to distinguish non-transgenic and transgenic soybean oils.

  9. Method for rapid detection and identification of chaetomium and evaluation of resistance to peracetic acid.

    Science.gov (United States)

    Nakayama, Motokazu; Hosoya, Kouichi; Tomiyama, Daisuke; Tsugukuni, Takashi; Matsuzawa, Tetsuhiro; Imanishi, Yumi; Yaguchi, Takashi

    2013-06-01

    In the beverage industry, peracetic acid has been increasingly used as a disinfectant for the filling machinery and environment due to merits of leaving no residue, it is safe for humans, and its antiseptic effect against fungi and endospores of bacteria. Recently, Chaetomium globosum and Chaetomium funicola were reported resistant to peracetic acid; however, little is known concerning the detail of peracetic acid resistance. Therefore, we assessed the peracetic acid resistance of the species of Chaetomium and related genera under identical conditions and made a thorough observation of the microstructure of their ascospores by transmission electron microscopy. The results of analyses revealed that C. globosum and C. funicola showed the high resistance to peracetic acid (a 1-D antiseptic effect after 900 s and 3-D antiseptic effect after 900 s) and had thick cell walls of ascospores that can impede the action mechanism of peracetic acid. We also developed specific primers to detect the C. globosum clade and identify C. funicola by using PCR to amplify the β-tubulin gene. PCR with the primer sets designed for C. globosum (Chae 4F/4R) and C. funicola (Cfu 2F/2R) amplified PCR products specific for the C. globosum clade and C. funicola, respectively. PCR with these two primer sets did not detect other fungi involved in food spoilage and environmental contamination. This detection and identification method is rapid and simple, with extremely high specificity.

  10. New method and installation for rapid determination of radon diffusion coefficient in various materials

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-01-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10 −12 to 5·10 −5 m 2 /s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). - Highlights: • The new method and installation for determination of radon diffusion coefficient D are developed. • The measured D-values vary in an extremely wide range, from 5×10 -5 to 1×10 -12 m 2 /s. • The materials include water, air, soil, building materials and radon-proof membranes. • The duration of the single test does not exceed 18 hours. • The measurement uncertainty varies from 5% (in permeable materials) to 40% (in radon gas barriers)

  11. Rapid estimation of compost enzymatic activity by spectral analysis method combined with machine learning.

    Science.gov (United States)

    Chakraborty, Somsubhra; Das, Bhabani S; Ali, Md Nasim; Li, Bin; Sarathjith, M C; Majumdar, K; Ray, D P

    2014-03-01

    The aim of this study was to investigate the feasibility of using visible near-infrared (VisNIR) diffuse reflectance spectroscopy (DRS) as an easy, inexpensive, and rapid method to predict compost enzymatic activity, which traditionally measured by fluorescein diacetate hydrolysis (FDA-HR) assay. Compost samples representative of five different compost facilities were scanned by DRS, and the raw reflectance spectra were preprocessed using seven spectral transformations for predicting compost FDA-HR with six multivariate algorithms. Although principal component analysis for all spectral pretreatments satisfactorily identified the clusters by compost types, it could not separate different FDA contents. Furthermore, the artificial neural network multilayer perceptron (residual prediction deviation=3.2, validation r(2)=0.91 and RMSE=13.38 μg g(-1) h(-1)) outperformed other multivariate models to capture the highly non-linear relationships between compost enzymatic activity and VisNIR reflectance spectra after Savitzky-Golay first derivative pretreatment. This work demonstrates the efficiency of VisNIR DRS for predicting compost enzymatic as well as microbial activity. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Lock-in thermography as a rapid and reproducible thermal characterization method for magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Lemal, Philipp; Geers, Christoph; Monnier, Christophe A.; Crippa, Federica; Daum, Leopold; Urban, Dominic A.; Rothen-Rutishauser, Barbara [Adolphe Merkle Institute, University of Fribourg, Chemin des Verdiers 4, CH-1700 Fribourg (Switzerland); Bonmarin, Mathias, E-mail: mathias.bonmarin@zhaw.ch [Institute of Computational Physics, Zurich University of Applied Sciences, Technikumstrasse 9, 8400 Winterthur (Switzerland); Petri-Fink, Alke, E-mail: alke.fink@unifr.ch [Adolphe Merkle Institute, University of Fribourg, Chemin des Verdiers 4, CH-1700 Fribourg (Switzerland); Chemistry Department, University of Fribourg, Chemin du Museé 9, CH-1700 Fribourg (Switzerland); Moore, Thomas L., E-mail: thomaslee.moore@unifr.ch [Adolphe Merkle Institute, University of Fribourg, Chemin des Verdiers 4, CH-1700 Fribourg (Switzerland)

    2017-04-01

    Lock-in thermography (LIT) is a sensitive imaging technique generally used in engineering and materials science (e.g. detecting defects in composite materials). However, it has recently been expanded for investigating the heating power of nanomaterials, such as superparamagnetic iron oxide nanoparticles (SPIONs). Here we implement LIT as a rapid and reproducible method that can evaluate the heating potential of various sizes of SPIONs under an alternating magnetic field (AMF), as well as the limits of detection for each particle size. SPIONs were synthesized via thermal decomposition and stabilized in water via a ligand transfer process. Thermographic measurements of SPIONs were made by stimulating particles of varying sizes and increasing concentrations under an AMF. Furthermore, a commercially available SPION sample was included as an external reference. While the size dependent heating efficiency of SPIONs has been previously described, our objective was to probe the sensitivity limits of LIT. For certain size regimes it was possible to detect signals at concentrations as low as 0.1 mg Fe/mL. Measuring at different concentrations enabled a linear regression analysis and extrapolation of the limit of detection for different size nanoparticles. - Highlights: • A multi-sample screening assessment of magnetic nanoparticle thermal characteristics is shown via lock-in thermography. • Lower concentration limit of nanoparticle detection based on particle size is proposed. • A commercially available reference sample indicates the stability and reproducibility of LIT.

  13. Method and apparatus for rapid adjustment of process gas inventory in gaseous diffusion cascades

    International Nuclear Information System (INIS)

    Dyer, R.H.; Fowler, A.H.; Vanstrum, P.R.

    1977-01-01

    The invention relates to an improved method and system for making relatively large and rapid adjustments in the process gas inventory of an electrically powered gaseous diffusion cascade in order to accommodate scheduled changes in the electrical power available for cascade operation. In the preferred form of the invention, the cascade is readied for a decrease in electrical input by simultaneously withdrawing substreams of the cascade B stream into respective process-gas-freezing and storage zones while decreasing the datum-pressure inputs to the positioning systems for the cascade control valves in proportion to the weight of process gas so removed. Consequently, the control valve positions are substantially unchanged by the reduction in invention, and there is minimal disturbance of the cascade isotopic gradient. The cascade is readied for restoration of the power cut by simultaneously evaporating the solids in the freezing zones to regenerate the process gas substreams and introducing them to the cascade A stream while increasing the aforementioned datum pressure inputs in proportion to the weight of process gas so returned. In the preferred form of the system for accomplishing these operations, heat exchangers are provided for freezing, storing, and evaporating the various substreams. Preferably, the heat exchangers are connected to use existing cascade auxiliary systems as a heat sink. A common control is employed to adjust and coordinate the necessary process gas transfers and datum pressure adjustments

  14. HPLC method for rapidly following biodiesel fuel transesterification reaction progress using a core-shell column.

    Science.gov (United States)

    Allen, Samuel J; Ott, Lisa S

    2012-07-01

    There are a wide and growing variety of feedstocks for biodiesel fuel. Most commonly, these feedstocks contain triglycerides which are transesterified into the fatty acid alkyl esters (FAAEs) which comprise biodiesel fuel. While the tranesterification reaction itself is simple, monitoring the reaction progress and reaction products is not. Gas chromatography-mass spectrometry is useful for assessing the FAAE products, but does not directly address either the tri-, di-, or monoglycerides present from incomplete transesterification or the free fatty acids which may also be present. Analysis of the biodiesel reaction mixture is complicated by the solubility and physical property differences among the components of the tranesterification reaction mixture. In this contribution, we present a simple, rapid HPLC method which allows for monitoring all of the main components in a biodiesel fuel transesterification reaction, with specific emphasis on the ability to monitor the reaction as a function of time. The utilization of a relatively new, core-shell stationary phase for the HPLC column allows for efficient separation of peaks with short elution times, saving both time and solvent.

  15. Arbitrarily primed PCR- A rapid and simple method for typing of leptospiral serovars

    Directory of Open Access Journals (Sweden)

    Ramadass P

    2002-01-01

    Full Text Available PURPOSE: To investigate the use of arbitrarily primed polymerase chain reaction (AP-PCR for typing of leptospiral serovars. METHODS: AP-PCR was adopted for identification of laboratory strains of leptospires and leptospiral cultures at serovar level. A primer of 12 bp was used for amplifying DNA of 13 laboratory strains of leptospires as well as culture pellets of leptospires. RESULTS: Each serovar produced distinct DNA fingerprint which was characteristic for each serovar. These patterns were used for typing of 81 serum culture samples obtained from human leptospiral cases. Of these samples, 39 could be typed based on AP-PCR fingerprints belonging to serovars autumnalis, pomona, canicola, javanica, icterohaemorrhagiae, patoc and pyrogenes. These results were confirmed by RAPD fingerprinting of the DNA samples of the respective leptospiral serovars after culturing -FNx01them in EMJH media. One of the important findings of this work was that straight culture sample could be used for AP-PCR assay, without purification of DNA. By having more number of AP-PCR reference fingerprints, more serovars could be typed. CONCLUSIONS: AP-PCR technique provides great potential for simple and rapid identification of leptospires at serovar level, which could be useful in molecular epidemiological studies of leptospirosis.

  16. Improvements in fast-neutron spectroscopy methods (1961); Amelioration des methodes de spectrometrie des neutrons rapides (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Cambou, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-02-15

    This research aimed at improving fast-neutron electronic detectors based on n-p elastic scattering. The first part concerns proportional counters; careful constructional methods have made it possible to plot mono-energetic neutron spectra in the range 700 keV - 3 MeV with a resolution of 7 per cent. The second part concerns scintillation counters: an organic scintillator and an inorganic scintillator covered with a thin layer of a scattering agent. An exact study of the types of scintillation has made it possible to develop efficient discriminator circuits. Different neutron spectra plotted in the presence of a strong gamma background are presented. The last part deals with the development of form discrimination methods for the study, in the actual beam, of the elastic scattering of 14.58 MeV electrons. With hydrogen, the distribution f ({phi}) of the recoil protons is f({phi}) = 1 + 0.034 cos {phi} + 0.042 cos{sup 2} {phi}. With tritium the scattering is strongly anisotropic; the curve representing the variation of the differential cross-section for the elastic scattering in the centre of mass system is obtained with a target containing 1 cm{sup 3} of tritium. (author) [French] Le travail a porte sur l'amelioration des detecteurs electroniques de neutrons rapides bases sur la diffusion elastique n-p. La premiere partie est relative aux compteurs proportionnels; des methodes soignees de fabrication ont permis des traces de spectres de neutrons monoenergetiques dans le domaine 700 keV - 3 MeV avec une resolution de 7 pour cent. La deuxieme partie est relative au compteur a scintillations; scintillateur organique et scintillateur mineral recouvert d'un diffuseur mince. Une etude precise des formes de scintillations a permis la mise au point de circuits discriminateurs efficaces. Differents spectres de neutrons traces en presence d'un fond gamma intense sont presentes. La derniere partie est relative a la mise en oeuvre des methodes de discrimination de forme pour l

  17. Applying polarity rapid assessment method and ultrafiltration to characterize NDMA precursors in wastewater effluents.

    Science.gov (United States)

    Chen, Chao; Leavey, Shannon; Krasner, Stuart W; Mel Suffet, I H

    2014-06-15

    Certain nitrosamines in water are disinfection byproducts that are probable human carcinogens. Nitrosamines have diverse and complex precursors that include effluent organic matter, some anthropogenic chemicals, and natural (likely non-humic) substances. An easy and selective tool was first developed to characterize nitrosamine precursors in treated wastewaters, including different process effluents. This tool takes advantages of the polarity rapid assessment method (PRAM) and ultrafiltration (UF) (molecular weight distribution) to locate the fractions with the strongest contributions to the nitrosamine precursor pool in the effluent organic matter. Strong cation exchange (SCX) and C18 solid-phase extraction cartridges were used for their high selectivity for nitrosamine precursors. The details of PRAM operation, such as cartridge clean-up, capacity, pH influence, and quality control were included in this paper, as well as the main parameters of UF operation. Preliminary testing of the PRAM/UF method with effluents from one wastewater treatment plant gave very informative results. SCX retained 45-90% of the N-nitrosodimethylamine (NDMA) formation potential (FP)-a measure of the precursors-in secondary and tertiary wastewater effluents. These results are consistent with NDMA precursors likely having a positively charged amine group. C18 adsorbed 30-45% of the NDMAFP, which indicates that a substantial portion of these precursors were non-polar. The small molecular weight (MW) (10 kDa) fractions obtained from UF were the primary contributors to NDMAFP. The combination of PRAM and UF brings important information on the characteristics of nitrosamine precursors in water with easy operation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. A rapid method for assessing the environmental performance of commercial farms in the Pampas of Argentina.

    Science.gov (United States)

    Viglizzo, E F; Frank, F; Bernardos, J; Buschiazzo, D E; Cabo, S

    2006-06-01

    The generation of reliable updated information is critical to support the harmonization of socio-economic and environmental issues in a context of sustainable development. The agro-environmental assessment and management of agricultural systems often relies on indicators that are necessary to make sound decisions. This work aims to provide an approach to (a) assess the environmental performance of commercial farms in the Pampas of Argentina, and (b) propose a methodological framework to calculate environmental indicators that can rapidly be applied to practical farming. 120 commercial farms scattered across the Pampas were analyzed in this study during 2002 and 2003. Eleven basic indicators were identified and calculation methods described. Such indicators were fossil energy (FE) use, FE use efficiency, nitrogen (N) balance, phosphorus (P) balance, N contamination risk, P contamination risk, pesticide contamination risk, soil erosion risk, habitat intervention, changes in soil carbon stock, and balance of greenhouse gases. A model named Agro-Eco-Index was developed on a Microsoft-Excel support to incorporate on-farm collected data and facilitate the calculation of indicators by users. Different procedures were applied to validate the model and present the results to the users. Regression models (based on linear and non-linear models) were used to validate the comparative performance of the study farms across the Pampas. An environmental dashboard was provided to represent in a graphical way the behavior of farms. The method provides a tool to discriminate environmentally friendly farms from those that do not pay enough attention to environmental issues. Our procedure might be useful for implementing an ecological certification system to reward a good environmental behavior in society (e.g., through tax benefits) and generate a commercial advantage (e.g., through the allocation of green labels) for committed farmers.

  19. Embryonic Zebrafish Model - A Well-Established Method for Rapidly Assessing the Toxicity of Homeopathic Drugs

    Science.gov (United States)

    Gupta, Himanshu R; Patil, Yogesh; Singh, Dipty

    2016-01-01

    in this study. The embryonic zebrafish model is recommended as a well-established method for rapidly assessing the toxicity of homeopathic drugs. PMID:28127503

  20. Rapid screening method for male DNA by using the loop-mediated isothermal amplification assay.

    Science.gov (United States)

    Kitamura, Masashi; Kubo, Seiji; Tanaka, Jin; Adachi, Tatsushi

    2017-08-12

    Screening for male-derived biological material from collected samples plays an important role in criminal investigations, especially those involving sexual assaults. We have developed a loop-mediated isothermal amplification (LAMP) assay targeting multi-repeat sequences of the Y chromosome for detecting male DNA. Successful amplification occurred with 0.5 ng of male DNA under isothermal conditions of 61 to 67 °C, but no amplification occurred with up to 10 ng of female DNA. Under the optimized conditions, the LAMP reaction initiated amplification within 10 min and amplified for 20 min. The LAMP reaction was sensitive at levels as low as 1-pg male DNA, and a quantitative LAMP assay could be developed because of the strong correlation between the reaction time and the amount of template DNA in the range of 10 pg to 10 ng. Furthermore, to apply the LAMP assay to on-site screening for male-derived samples, we evaluated a protocol using a simple DNA extraction method and a colorimetric intercalating dye that allows detection of the LAMP reaction by evaluating the change in color of the solution. Using this protocol, samples of male-derived blood and saliva stains were processed in approximately 30 min from DNA extraction to detection. Because our protocol does not require much hands-on time or special equipment, this LAMP assay promises to become a rapid and simple screening method for male-derived samples in forensic investigations.